WorldWideScience

Sample records for removal system baseline

  1. Pentek metal coating removal system: Baseline report

    International Nuclear Information System (INIS)

    1997-01-01

    The Pentek coating removal technology was tested and is being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The Pentek coating removal system consisted of the ROTO-PEEN Scaler, CORNER-CUTTER reg-sign, and VAC-PAC reg-sign. They are designed to remove coatings from steel, concrete, brick, and wood. The Scaler uses 3M Roto Peen tungsten carbide cutters while the CORNER-CUTTER reg-sign uses solid needles for descaling activities. These hand tools are used with the VAC-PAC reg-sign vacuum system to capture dust and debris as removal of the coating takes place. The safety and health evaluation during the testing demonstration focused on two main areas of exposure: dust and noise. Dust exposure minimal, but noise exposure was significant. Further testing for each exposure is recommended because of the environment where the testing demonstration took place. It is feasible that the dust and noise levels will be higher in an enclosed operating environment of different construction. In addition, other areas of concern found were arm-hand vibration, whole-body, ergonomics, heat stress, tripping hazards, electrical hazards, machine guarding, and lockout/tagout

  2. Pentek metal coating removal system: Baseline report; Greenbook (chapter)

    International Nuclear Information System (INIS)

    1997-01-01

    The Pentek coating removal technology was tested and is being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The Pentek coating removal system consisted of the ROTO-PEEN Scaler, CORNER-CUTTER reg-sign, and VAC-PAC reg-sign. They are designed to remove coatings from steel, concrete, brick, and wood. The Scaler uses 3M Roto Peen tungsten carbide cutters while the CORNER-CUTTER reg-sign uses solid needles for descaling activities. These hand tools are used with the VAC-PAC reg-sign vacuum system to capture dust and debris as removal of the coating takes place. The safety and health evaluation during the testing demonstration focused on two main areas of exposure: dust and noise. Dust exposure minimal, but noise exposure was significant. Further testing for each exposure is recommended because of the environment where the testing demonstration took place. It is feasible that the dust and noise levels will be higher in an enclosed operating environment of different construction. In addition, other areas of concern found were arm-hand vibration, whole-body, ergonomics, heat stress, tripping hazards, electrical hazards, machine guarding, and lockout/tagout

  3. A Fully Customized Baseline Removal Framework for Spectroscopic Applications.

    Science.gov (United States)

    Giguere, Stephen; Boucher, Thomas; Carey, C J; Mahadevan, Sridhar; Dyar, M Darby

    2017-07-01

    The task of proper baseline or continuum removal is common to nearly all types of spectroscopy. Its goal is to remove any portion of a signal that is irrelevant to features of interest while preserving any predictive information. Despite the importance of baseline removal, median or guessed default parameters are commonly employed, often using commercially available software supplied with instruments. Several published baseline removal algorithms have been shown to be useful for particular spectroscopic applications but their generalizability is ambiguous. The new Custom Baseline Removal (Custom BLR) method presented here generalizes the problem of baseline removal by combining operations from previously proposed methods to synthesize new correction algorithms. It creates novel methods for each technique, application, and training set, discovering new algorithms that maximize the predictive accuracy of the resulting spectroscopic models. In most cases, these learned methods either match or improve on the performance of the best alternative. Examples of these advantages are shown for three different scenarios: quantification of components in near-infrared spectra of corn and laser-induced breakdown spectroscopy data of rocks, and classification/matching of minerals using Raman spectroscopy. Software to implement this optimization is available from the authors. By removing subjectivity from this commonly encountered task, Custom BLR is a significant step toward completely automatic and general baseline removal in spectroscopic and other applications.

  4. MALDI-TOF Baseline Drift Removal Using Stochastic Bernstein Approximation

    Directory of Open Access Journals (Sweden)

    Howard Daniel

    2006-01-01

    Full Text Available Stochastic Bernstein (SB approximation can tackle the problem of baseline drift correction of instrumentation data. This is demonstrated for spectral data: matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF data. Two SB schemes for removing the baseline drift are presented: iterative and direct. Following an explanation of the origin of the MALDI-TOF baseline drift that sheds light on the inherent difficulty of its removal by chemical means, SB baseline drift removal is illustrated for both proteomics and genomics MALDI-TOF data sets. SB is an elegant signal processing method to obtain a numerically straightforward baseline shift removal method as it includes a free parameter that can be optimized for different baseline drift removal applications. Therefore, research that determines putative biomarkers from the spectral data might benefit from a sensitivity analysis to the underlying spectral measurement that is made possible by varying the SB free parameter. This can be manually tuned (for constant or tuned with evolutionary computation (for .

  5. Tritium effluent removal system

    International Nuclear Information System (INIS)

    Lamberger, P.H.; Gibbs, G.E.

    1978-01-01

    An air detritiation system has been developed and is in routine use for removing tritium and tritiated compounds from glovebox effluent streams before they are released to the atmosphere. The system is also used, in combination with temporary enclosures, to contain and decontaminate airborne releases resulting from the opening of tritium containment systems during maintenance and repair operations. This detritiation system, which services all the tritium handling areas at Mound Facility, has played an important role in reducing effluents and maintaining them at 2 percent of the level of 8 y ago. The system has a capacity of 1.7 m 3 /min and has operated around the clock for several years. A refrigerated in-line filtration system removes water, mercury, or pump oil and other organics from gaseous waste streams. The filtered waste stream is then heated and passed through two different types of oxidizing beds; the resulting tritiated water is collected on molecular sieve dryer beds. Liquids obtained from regenerating the dryers and from the refrigerated filtration system are collected and transferred to a waste solidification and packaging station. Component redundancy and by-pass capabilities ensure uninterrupted system operation during maintenance. When processing capacity is exceeded, an evacuated storage tank of 45 m 3 is automatically opened to the inlet side of the system. The gaseous effluent from the system is monitored for tritium content and recycled or released directly to the stack. The average release is less than 1 Ci/day. The tritium effluent can be reduced by isotopically swamping the tritium; this is accomplished by adding hydrogen prior to the oxidizer beds, or by adding water to the stream between the two final dryer beds

  6. Structure of a traditional baseline data system

    Energy Technology Data Exchange (ETDEWEB)

    1976-12-01

    Research was conducted to determine whether appropriate data exist for the development of a comprehensive statistical baseline data system on the human environment in the Athabasca oil sands region of Alberta. The existing data sources pertinent to the target area were first reviewed and discussed. Criteria were selected to assist the evaluation of data, including type of data collected, source, degree of detail, geographic identification, accessibility, and time frame. These criteria allowed assessing whether the data would be amenable to geographically-coded, continuous monitoring systems. It was found that the Statistics Canada Census provided the most detail, the most complete coverage of the target area, the smallest statistical areas, the greatest consistency in data and data collection, and the most regular collection. The local agency collection efforts were generally oriented toward specific goals and the data intended primarily for intra-agency use. The smallest statistical units in these efforts may be too large to be of value to a common small-area system, and data collection agencies did not generally use coterminous boundaries. Recommendations were made to give primary consideration to Statistics Canada data in the initial development of the baseline data system. Further development of such a system depends on the adoption by local agencies of a common small-area system for data collection. 38 refs., 6 figs.

  7. 1993 baseline solid waste management system description

    International Nuclear Information System (INIS)

    Armacost, L.L.; Fowler, R.A.; Konynenbelt, H.S.

    1994-02-01

    Pacific Northwest Laboratory has prepared this report under the direction of Westinghouse Hanford Company. The report provides an integrated description of the system planned for managing Hanford's solid low-level waste, low-level mixed waste, transuranic waste, and transuranic mixed waste. The primary purpose of this document is to illustrate a collective view of the key functions planned at the Hanford Site to handle existing waste inventories, as well as solid wastes that will be generated in the future. By viewing this system as a whole rather than as individual projects, key facility interactions and requirements are identified and a better understanding of the overall system may be gained. The system is described so as to form a basis for modeling the system at various levels of detail. Model results provide insight into issues such as facility capacity requirements, alternative system operating strategies, and impacts of system changes (ie., startup dates). This description of the planned Hanford solid waste processing system: defines a baseline system configuration; identifies the entering waste streams to be managed within the system; identifies basic system functions and waste flows; and highlights system constraints. This system description will evolve and be revised as issues are resolved, planning decisions are made, additional data are collected, and assumptions are tested and changed. Out of necessity, this document will also be revised and updated so that a documented system description, which reflects current system planning, is always available for use by engineers and managers. It does not provide any results generated from the many alternatives that will be modeled in the course of analyzing solid waste disposal options; such results will be provided in separate documents

  8. Baseline Architecture of ITER Control System

    Science.gov (United States)

    Wallander, A.; Di Maio, F.; Journeaux, J.-Y.; Klotz, W.-D.; Makijarvi, P.; Yonekawa, I.

    2011-08-01

    The control system of ITER consists of thousands of computers processing hundreds of thousands of signals. The control system, being the primary tool for operating the machine, shall integrate, control and coordinate all these computers and signals and allow a limited number of staff to operate the machine from a central location with minimum human intervention. The primary functions of the ITER control system are plant control, supervision and coordination, both during experimental pulses and 24/7 continuous operation. The former can be split in three phases; preparation of the experiment by defining all parameters; executing the experiment including distributed feed-back control and finally collecting, archiving, analyzing and presenting all data produced by the experiment. We define the control system as a set of hardware and software components with well defined characteristics. The architecture addresses the organization of these components and their relationship to each other. We distinguish between physical and functional architecture, where the former defines the physical connections and the latter the data flow between components. In this paper, we identify the ITER control system based on the plant breakdown structure. Then, the control system is partitioned into a workable set of bounded subsystems. This partition considers at the same time the completeness and the integration of the subsystems. The components making up subsystems are identified and defined, a naming convention is introduced and the physical networks defined. Special attention is given to timing and real-time communication for distributed control. Finally we discuss baseline technologies for implementing the proposed architecture based on analysis, market surveys, prototyping and benchmarking carried out during the last year.

  9. CRBRP decay heat removal systems

    International Nuclear Information System (INIS)

    Hottel, R.E.; Louison, R.; Boardman, C.E.; Kiley, M.J.

    1977-01-01

    The Decay Heat Removal Systems for the Clinch River Breeder Reactor Plant (CRBRP) are designed to adequately remove sensible and decay heat from the reactor following normal shutdown, operational occurrences, and postulated accidents on both a short term and a long term basis. The Decay Heat Removal Systems are composed of the Main Heat Transport System, the Main Condenser and Feedwater System, the Steam Generator Auxiliary Heat Removal System (SGAHRS), and the Direct Heat Removal Service (DHRS). The overall design of the CRBRP Decay Heat Removal Systems and the operation under normal and off-normal conditions is examined. The redundancies of the system design, such as the four decay heat removal paths, the emergency diesel power supplies, and the auxiliary feedwater pumps, and the diversities of the design such as forced circulation/natural circulation and AC Power/DC Power are presented. In addition to overall design and system capabilities, the detailed designs for the Protected Air Cooled Condensers (PACC) and the Air Blast Heat Exchangers (ABHX) are presented

  10. Linear MALDI-ToF simultaneous spectrum deconvolution and baseline removal.

    Science.gov (United States)

    Picaud, Vincent; Giovannelli, Jean-Francois; Truntzer, Caroline; Charrier, Jean-Philippe; Giremus, Audrey; Grangeat, Pierre; Mercier, Catherine

    2018-04-05

    Thanks to a reasonable cost and simple sample preparation procedure, linear MALDI-ToF spectrometry is a growing technology for clinical microbiology. With appropriate spectrum databases, this technology can be used for early identification of pathogens in body fluids. However, due to the low resolution of linear MALDI-ToF instruments, robust and accurate peak picking remains a challenging task. In this context we propose a new peak extraction algorithm from raw spectrum. With this method the spectrum baseline and spectrum peaks are processed jointly. The approach relies on an additive model constituted by a smooth baseline part plus a sparse peak list convolved with a known peak shape. The model is then fitted under a Gaussian noise model. The proposed method is well suited to process low resolution spectra with important baseline and unresolved peaks. We developed a new peak deconvolution procedure. The paper describes the method derivation and discusses some of its interpretations. The algorithm is then described in a pseudo-code form where the required optimization procedure is detailed. For synthetic data the method is compared to a more conventional approach. The new method reduces artifacts caused by the usual two-steps procedure, baseline removal then peak extraction. Finally some results on real linear MALDI-ToF spectra are provided. We introduced a new method for peak picking, where peak deconvolution and baseline computation are performed jointly. On simulated data we showed that this global approach performs better than a classical one where baseline and peaks are processed sequentially. A dedicated experiment has been conducted on real spectra. In this study a collection of spectra of spiked proteins were acquired and then analyzed. Better performances of the proposed method, in term of accuracy and reproductibility, have been observed and validated by an extended statistical analysis.

  11. Pentek concrete scabbling system: Baseline report; Greenbook (chapter)

    International Nuclear Information System (INIS)

    1997-01-01

    The Pentek scabbling technology was tested at Florida International University (FIU) and is being evaluated as a baseline technology. This report evaluates it for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The Pentek concrete scabbling system consisted of the MOOSE, SQUIRREL-I, and SQUIRREL-III scabblers. The scabblers are designed to scarify concrete floors and slabs using cross-section, tungsten carbide tipped bits. The bits are designed to remove concrete in 318 inch increments. The bits are either 9-tooth or demolition type. The scabblers are used with a vacuum system designed to collect and filter the concrete dust and contamination that is removed from the surface. The safety and health evaluation conducted during the testing demonstration focused on two main areas of exposure: dust and noise. Dust exposure was minimal, but noise exposure was significant. Further testing for each of these exposures is recommended. Because of the outdoor environment where the testing demonstration took place, results may be inaccurate. It is feasible that the dust and noise levels will be higher in an enclosed operating environment. Other areas of concern were arm-hand vibration, whole-body vibration, ergonomics, heat stress, tripping hazards, electrical hazards, machine guarding, and lockout/tagout

  12. Hot Spot Removal System: System description

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    Hazardous wastes contaminated with radionuclides, chemicals, and explosives exist across the Department of Energy complex and need to be remediated due to environmental concerns. Currently, an opportunity is being developed to dramatically reduce remediation costs and to assist in the acceleration of schedules associated with these wastes by deploying a Hot Spot Removal System. Removing the hot spot from the waste site will remove risk driver(s) and enable another, more cost effective process/option/remedial alternative (i.e., capping) to be applied to the remainder of the site. The Hot Spot Removal System consists of a suite of technologies that will be utilized to locate and remove source terms. Components of the system can also be used in a variety of other cleanup activities. This Hot Spot Removal System Description document presents technologies that were considered for possible inclusion in the Hot Spot Removal System, technologies made available to the Hot Spot Removal System, industrial interest in the Hot Spot Removal System`s subsystems, the schedule required for the Hot Spot Removal System, the evaluation of the relevant technologies, and the recommendations for equipment and technologies as stated in the Plan section.

  13. Hot Spot Removal System: System description

    International Nuclear Information System (INIS)

    1997-09-01

    Hazardous wastes contaminated with radionuclides, chemicals, and explosives exist across the Department of Energy complex and need to be remediated due to environmental concerns. Currently, an opportunity is being developed to dramatically reduce remediation costs and to assist in the acceleration of schedules associated with these wastes by deploying a Hot Spot Removal System. Removing the hot spot from the waste site will remove risk driver(s) and enable another, more cost effective process/option/remedial alternative (i.e., capping) to be applied to the remainder of the site. The Hot Spot Removal System consists of a suite of technologies that will be utilized to locate and remove source terms. Components of the system can also be used in a variety of other cleanup activities. This Hot Spot Removal System Description document presents technologies that were considered for possible inclusion in the Hot Spot Removal System, technologies made available to the Hot Spot Removal System, industrial interest in the Hot Spot Removal System''s subsystems, the schedule required for the Hot Spot Removal System, the evaluation of the relevant technologies, and the recommendations for equipment and technologies as stated in the Plan section

  14. Pakistan, Sindh Province - Baseline Indicators System : Baseline Procurement Performance Assessment Report

    OpenAIRE

    World Bank

    2009-01-01

    This document provides an assessment of the public procurement system in Sindh province using the baseline indicators system developed by the Development Assistance Committee of the Organization for Economic Cooperation and Development (OECD-DAC). This assessment, interviews and discussions were held with stakeholders from the public and private sectors as well as civil society. Developing...

  15. 1995 Baseline solid waste management system description

    International Nuclear Information System (INIS)

    Anderson, G.S.; Konynenbelt, H.S.

    1995-09-01

    This provides a detailed solid waste system description that documents the treatment, storage, and disposal (TSD) strategy for managing Hanford's solid low-level waste, low-level mixed waste, transuranic and transuranic mixed waste, and greater-than-Class III waste. This system description is intended for use by managers of the solid waste program, facility and system planners, as well as system modelers. The system description identifies the TSD facilities that constitute the solid waste system and defines these facilities' interfaces, schedules, and capacities. It also provides the strategy for treating each of the waste streams generated or received by the Hanford Site from generation or receipt through final destination

  16. Containment heat removal system

    International Nuclear Information System (INIS)

    Wade, G.E.; Barbanti, G.; Gou, P.F.; Rao, A.S.; Hsu, L.C.

    1992-01-01

    This patent describes a nuclear system of a type including a containment having a nuclear reactor therein, the nuclear reactor including a pressure vessel and a core in the pressure vessel, the system. It comprises a gravity pool of coolant disposed at an elevation sufficient to permit a flow of coolant into the nuclear reactor pressure vessel against a predetermined pressure within the nuclear reactor pressure vessel; means for reducing a pressure of steam in the nuclear reactor pressure vessel to a value less than the predetermined pressure in the event of a nuclear accident, the means including a depressurization valve connected to the pressure vessel, the means further including steam heat dissipating means such dissipating means including a suppression pool; a supply of water in the suppression pool, there being a headspace in the suppression pool above the water supply; a substantial amount of air in the head space; means for feeding pressurized steam from the nuclear reactor pressure vessel to a location under a surface of the supply of water, the supply of water being effective to absorb heat sufficient to reduce steam pressure below the predetermined pressure; and a check valve for communicating the headspace with the containment, the check valve being oriented to vent air in the headspace to the containment when a pressure in the headspace exceeds a pressure in the containment by a predetermined pressure differential

  17. After-heat removal system

    International Nuclear Information System (INIS)

    Yamamoto, Michiyoshi; Mitani, Shinji.

    1982-01-01

    Purpose: To prevent contamination of suppression pool water and intrusion of corrosion products into a nuclear reactor. Constitution: Upon stop of an after-heat removing system, reactor water contained in pipelines is drained out to a radioactive wastes processing facility at the time the cooling operation mode has been completed. At the same time, water is injected from a pure water supply system to the after-heat removing system to discharge corrosion product and activated materials while cleaning the inside of the pipelines. Then, pure water is held in the pipelines and it is discharged again and replaced with pure water before entering the cooling mode operation. Thereafter, the cooling mode operation upon reactor shutdown is performed. (Yoshino, Y.)

  18. Active Space Debris Removal System

    Directory of Open Access Journals (Sweden)

    Gabriele GUERRA

    2017-06-01

    Full Text Available Since the start of the space era, more than 5000 launches have been carried out, each carrying satellites for many disparate uses, such as Earth observation or communication. Thus, the space environment has become congested and the problem of space debris is now generating some concerns in the space community due to our long-lived belief that “space is big”. In the last few years, solutions to this problem have been proposed, one of those is Active Space Debris Removal: this method will reduce the increasing debris growth and permit future sustainable space activities. The main idea of the method proposed below is a drag augmentation system: use a system capable of putting an expanded foam on a debris which will increase the area-to-mass ratio to increase the natural atmospheric drag and solar pressure. The drag augmentation system proposed here requires a docking system; the debris will be pushed to its release height and then, after un-docking, an uncontrolled re-entry takes place ending with a burn up of the object and the foam in the atmosphere within a given time frame. The method requires an efficient way to change the orbit between two debris. The present paper analyses such a system in combination with an Electric Propulsion system, and emphasizes the choice of using two satellites to remove five effective rockets bodies debris within a year.

  19. VDTT removal system functional design criteria

    International Nuclear Information System (INIS)

    Legare, D.E.

    1996-01-01

    Two Velocity Density Temperature Trees (H-2-815016) are to be removed from risers 14A and 1B of tank 241-SY-101. This document provides functional design criteria for the removal system. The removal system consists of a Liquid Removal Tool, Flexible Receiver (H-2-79216), Burial Container, Transport Trailers, and associated equipment

  20. Overview of the Long-Baseline Neutrino Facility cryogenic system

    CERN Document Server

    Montanari, David; Bremer, Johan; Delaney, Michael; Aurelien, Diaz; Doubnik, Roza; Haaf, Kevin; Hentschel, Steve; Norris, Barry; Voirin, Erik

    2017-01-01

    The Deep Underground Neutrino Experiment (DUNE) collaboration is developing a multi-kiloton Long-Baseline neutrino experiment that will be located one mile underground at the Sanford Underground Research Facility (SURF) in Lead, SD. In the present design, detectors will be located inside four cryostats filled with a total of 68,400 ton of ultrapure liquid argon, at the level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The Long-Baseline Neutrino Facility (LBNF) is developing the conventional facilities and cryogenics infrastructure supporting this experiment. The cryogenics system is composed of several sub-systems: External/Infrastructure, Proximity, and Internal cryogenics. It will be engineered, manufactured, commissioned, and qualified by an international engineering team. This contribution highlights the main features of the LBNF cryogenic system. It presents its performance, functional requirements and modes of operations. It also details the status of the design, ...

  1. Integrated Baseline System (IBS) Version 1.03: Utilities guide

    Energy Technology Data Exchange (ETDEWEB)

    Burford, M.J.; Downing, T.R.; Pottier, M.C.; Schrank, E.E.; Williams, J.R.

    1993-01-01

    The Integrated Baseline System (IBS) is an emergency management planning and analysis tool that was developed under the direction of the Federal Emergency Management Agency (FEMA). This Utilities Guide explains how to operate utility programs that are supplied as a part of the IBS. These utility programs are chiefly for managing and manipulating various kinds of IBS data and system administration files. Many of the utilities are for creating, editing, converting, or displaying map data and other data that are related to geographic location.

  2. Integrated Baseline System (IBS) Version 2.0: Utilities Guide

    Energy Technology Data Exchange (ETDEWEB)

    Burford, M.J.; Downing, T.R.; Williams, J.R. [Pacific Northwest Lab., Richland, WA (United States); Bower, J.C. [Bower Software Services, Kennewick, WA (United States)

    1994-03-01

    The Integrated Baseline System (IBS) is an emergency management planning and analysis tool being developed under the direction of the US Army Nuclear and Chemical Agency. This Utilities Guide explains how you can use the IBS utility programs to manage and manipulate various kinds of IBS data. These programs include utilities for creating, editing, and displaying maps and other data that are referenced to geographic location. The intended audience for this document are chiefly data managers but also system managers and some emergency management planners and analysts.

  3. Integrated Baseline System (IBS) Version 2.0: Models guide

    Energy Technology Data Exchange (ETDEWEB)

    1994-03-01

    The Integrated Baseline System (IBS) is an emergency management planning and analysis tool being developed under the direction of the US Army Nuclear and Chemical Agency. This Models Guide summarizes the IBS use of several computer models for predicting the results of emergency situations. These include models for predicting dispersion/doses of airborne contaminants, traffic evacuation, explosion effects, heat radiation from a fire, and siren sound transmission. The guide references additional technical documentation on the models when such documentation is available from other sources. The audience for this manual is chiefly emergency management planners and analysts, but also data managers and system managers.

  4. Antipollution system to remove nitrogen dioxide gas

    Science.gov (United States)

    Metzler, A. J.; Slough, J. W.

    1971-01-01

    Gas phase reaction system using anhydrous ammonia removes nitrogen dioxide. System consists of ammonia injection and mixing section, reaction section /reactor/, and scrubber section. All sections are contained in system ducting.

  5. Baseline hydrologic studies in the lower Elwha River prior to dam removal

    Science.gov (United States)

    Magirl, Christopher S.; Curran, Christopher A.; Sheibley, Rich W.; Warrick, Jonathan A.; Czuba, Jonathan A.; Czuba, Christiana R.; Gendaszek, Andrew S.; Shafroth, Patrick B.; Duda, Jeffrey J.; Foreman, James R.

    2011-01-01

    After the removal of two large, long‑standing dams on the Elwha River, Washington, the additional load of sediment and wood is expected to affect the hydrology of the lower river, its estuary, and the alluvial aquifer underlying the surrounding flood plain. To better understand the surface-water and groundwater characteristics of the river and estuary before dam removal, several hydrologic data sets were collected and analyzed. An experiment using a dye tracer characterized transient storage, and it was determined that the low‑flow channel of the lower Elwha River was relatively simple; 1–6 percent of the median travel time of dye was attributed to transient‑storage processes. Water data from monitoring wells adjacent to the main‑stem river indicated a strong hydraulic connectivity between stage in the river and groundwater levels in the flood plain. Analysis of temperature data from the monitoring wells showed that changes in the groundwater temperature responded weeks or months after water temperature changed in the river. A seepage investigation indicated that water from the river was moving into the aquifer (losing

  6. System for removing contaminants from plastic resin

    Science.gov (United States)

    Bohnert, George W.; Hand, Thomas E.; DeLaurentiis, Gary M.

    2010-11-23

    A resin recycling system that produces essentially contaminant-free synthetic resin material in an environmentally safe and economical manner. The system includes receiving the resin in container form. A grinder grinds the containers into resin particles. The particles are exposed to a solvent in one or more solvent wash vessels, the solvent contacting the resin particles and substantially removing contaminants on the resin particles. A separator is used to separate the resin particles and the solvent. The resin particles are then placed in solvent removing element where they are exposed to a solvent removing agent which removes any residual solvent remaining on the resin particles after separation.

  7. System maintenance test plan for the TWRS controlled baseline database system

    International Nuclear Information System (INIS)

    Spencer, S.G.

    1998-01-01

    TWRS [Tank Waste Remediation System] Controlled Baseline Database, formally known as the Performance Measurement Control System, is used to track and monitor TWRS project management baseline information. This document contains the maintenance testing approach for software testing of the TCBD system once SCR/PRs are implemented

  8. Nuclear reactor auxiliary heat removal system

    International Nuclear Information System (INIS)

    Thompson, R.E.; Pierce, B.L.

    1977-01-01

    An auxiliary heat removal system to remove residual heat from gas-cooled nuclear reactors is described. The reactor coolant is expanded through a turbine, cooled in a heat exchanger and compressed by a compressor before reentering the reactor coolant. The turbine powers both the compressor and the pump which pumps a second fluid through the heat exchanger to cool the reactor coolant. A pneumatic starter is utilized to start the turbine, thereby making the auxiliary heat removal system independent of external power sources

  9. Tank waste remediation system technical baseline summary description

    International Nuclear Information System (INIS)

    Raymond, R.E.

    1998-01-01

    This document is one of the tools used to develop and control the mission work as depicted in the included figure. This Technical Baseline Summary Description document is the top-level tool for management of the Technical Baseline for waste storage operations

  10. Dust removal system for fusion experimental reactors

    International Nuclear Information System (INIS)

    Onozuka, M.; Ueda, Y.; Takahashi, K.; Oda, Y.; Seki, Y.; Ueda, S.; Aoki, I.

    1995-01-01

    Development of a dust removal system using static electricity has been conducted. It is envisioned that the system can collect and transport dust under vacuum. In the system, the dust is charged by dielectric polarization and floated by an electrostatic attraction force that is generated by the DC electric field. The dust is then transported by the electric curtain formed by the three-phase AC electric field. Experimental investigation has been conducted to examine the characteristics of the system. Current research results indicate that the dust removal system using static electricity can be used for fusion experimental reactors

  11. Dust removal system for fusion experimental reactors

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, M.; Ueda, Y.; Takahashi, K.; Oda, Y. [Mitsubishi Heavy Industries, Ltd., Yokohama (Japan); Seki, Y.; Ueda, S.; Aoki, I. [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan)

    1995-12-31

    Development of a dust removal system using static electricity has been conducted. It is envisioned that the system can collect and transport dust under vacuum. In the system, the dust is charged by dielectric polarization and floated by an electrostatic attraction force that is generated by the DC electric field. The dust is then transported by the electric curtain formed by the three-phase AC electric field. Experimental investigation has been conducted to examine the characteristics of the system. Current research results indicate that the dust removal system using static electricity can be used for fusion experimental reactors.

  12. Process and system for removing tritium

    International Nuclear Information System (INIS)

    Ridgely, J.N.

    1976-01-01

    A process and system for removing tritium, particularly from high temperature gas cooled atomic reactors (HTGR), is disclosed. Portions of the reactor coolant, which is permeated with the pervasive tritium atom, are processed to remove the tritium. Under conditions of elevated temperature and pressure, the reactor coolant is combined with gaseous oxygen, resulting in the formation of tritiated water vapor from the tritium in the reactor coolant and the gaseous oxygen. The tritiated water vapor and the remaining gaseous oxygen are then successively removed by fractional liquefaction steps. The reactor coolant is then recirculated to the reactor

  13. Forest Restoration Carbon Analysis of Baseline Carbon Emissions and Removal in Tropical Rainforest at La Selva Central, Peru

    Energy Technology Data Exchange (ETDEWEB)

    Patrick Gonzalez; Benjamin Kroll; Carlos R. Vargas

    2006-01-10

    Conversion of tropical forest to agricultural land and pasture has reduced forest extent and the provision of ecosystem services, including watershed protection, biodiversity conservation, and carbon sequestration. Forest conservation and reforestation can restore those ecosystem services. We have assessed forest species patterns, quantified deforestation and reforestation rates, and projected future baseline carbon emissions and removal in Amazon tropical rainforest at La Selva Central, Peru. The research area is a 4800 km{sup 2} buffer zone around the Parque Nacional Yanachaga-Chemillen, Bosque de Proteccion San Matias-San Carlos, and the Reserva Comunal Yanesha. A planned project for the period 2006-2035 would conserve 4000 ha of forest in a proposed 7000 ha Area de Conservacion Municipale de Chontabamba and establish 5600 ha of natural regeneration and 1400 ha of native species plantations, laid out in fajas de enriquecimiento (contour plantings), to reforest 7000 ha of agricultural land. Forest inventories of seven sites covering 22.6 ha in primary forest and 17 sites covering 16.5 ha in secondary forest measured 17,073 trees of diameter {ge} 10 cm. The 24 sites host trees of 512 species, 267 genera, and 69 families. We could not identify the family of 7% of the trees or the scientific species of 21% of the trees. Species richness is 346 in primary forest and 257 in the secondary forest. In primary forest, 90% of aboveground biomass resides in old-growth species. Conversely, in secondary forest, 66% of aboveground biomass rests in successional species. The density of trees of diameter {ge} 10 cm is 366 trees ha{sup -1} in primary forest and 533 trees ha{sup -1} in secondary forest, although the average diameter is 24 {+-} 15 cm in primary forest and 17 {+-} 8 cm in secondary forest. Using Amazon forest biomass equations and wood densities for 117 species, aboveground biomass is 240 {+-} 30 t ha{sup -1} in the primary sites and 90 {+-} 10 t ha{sup -1} in the

  14. Feasibility of passive heat removal systems

    Energy Technology Data Exchange (ETDEWEB)

    Ashurko, Yu M [Institute of Physics and Power Engineering, Obninsk (Russian Federation)

    1996-12-01

    This paper presents a review of decay heat removal systems (DHRSs) used in liquid metal-cooled fast reactors (LMFRs). Advantages and the disadvantages of these DHRSs, extent of their passivity and prospects for their use in advanced fast reactor projects are analyzed. Methods of extending the limitations on the employment of individual systems, allowing enhancement in their effectiveness as safety systems and assuring their total passivity are described. (author). 10 refs, 10 figs.

  15. CAREM-25: Residual heat removal system

    International Nuclear Information System (INIS)

    Arvia, Roberto P.; Coppari, Norberto R.; Gomez de Soler, Susana M.; Ramilo, Lucia B.

    2000-01-01

    The objective of this work was the definition and consolidation of the residual heat removal system for the CAREM 25 reactor. The function of this system is cool down the primary circuit, removing the core decay heat from hot stand-by to cold shutdown and during refueling. In addition, this system heats the primary water from the cold shutdown condition to hot stand-by condition during the reactor start up previous to criticality. The system has been designed according to the requirements of the standards: ANSI/ANS 51.1 'Nuclear safety criteria for the design of stationary PWR plants'; ANSI/ANS 58.11 'Design criteria for safe shutdown following selected design basis events in light water reactors' and ANSI/ANS 58.9 'Single failure criteria for light water reactor safety-related fluid systems'. The suggested design fulfills the required functions and design criteria standards. (author)

  16. Radiological/biological/aerosol removal system

    Science.gov (United States)

    Haslam, Jeffery J

    2015-03-17

    An air filter replacement system for existing buildings, vehicles, arenas, and other enclosed airspaces includes a replacement air filter for replacing a standard air filter. The replacement air filter has dimensions and air flow specifications that allow it to replace the standard air filter. The replacement air filter includes a filter material that removes radiological or biological or aerosol particles.

  17. Pegasus International, Inc. coating removal systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    The Pegasus Coating Removal System (PCRS) was demonstrated at Florida International University (FIU) where it was being evaluated for efficiency and cost. In conjunction with the FIU testing demonstration, a human factors assessment was conducted to assess the hazards and associated safety and health issues of concern for workers utilizing this technology. The PCRS is a chemical paste that is applied to the surface using a brush, roller, or airless sprayer. After the type of PCRS, thickness, and dwell time have been determined, a laminated backed material is placed on top of the chemical paste to slow down the drying process and to provide a mechanism to strip-off the chemical. After the dwell time is reached, the chemical substrate can be removed. Scrapers may be used to break-loose the layers as necessary or to break-loose the layers that are not removed when the laminated paper is picked up. Residue may also be cleaned off of the surface with a damp sponge with an agitating motion, absorbent sponges, or a vacuum, as needed. The paint and removal agent is then placed in drums for disposal at a later time. During the assessment sampling was conducted for organic vapors and general observational techniques were conducted for ergonomics. Recommendations for improved worker safety and health during application and removal of the PCRS include: (1) work practices that reflect avoidance of exposure or reducing the risk of exposure; (2) assuring all PPE and equipment are compatible with the chemicals being used; (3) work practices that reduce the worker`s need to walk on the slippery surface caused by the chemical or the use of special anti-slip soles; (4) careful control of overspray (if a spray application is used); and (5) the use of ergonomically designed long-handled tools to apply and remove the chemical (to alleviate some of the ergonomic concerns).

  18. West Valley waste removal system study

    International Nuclear Information System (INIS)

    Janicek, G.P.

    1981-04-01

    This study addresses the specific task of removing high-level wastes from underground tanks at Western New York Nuclear Center and delivering them to an onsite waste solidification plant. It begins with a review of the design and construction features of the waste storage tanks pertinent to the waste removal task with particular emphasis on the unique and complex tank internals which severely complicate the task of removal. It follows with a review of tank cleaning techniques used and under study at both Hanford and Savannah River and previous studies proposing the use of these techniques at West Valley. It concludes from these reviews that existing techniques are not directly transferable to West Valley and that a new approach is required utilizing selected feature and attributes from existing methodology. The study also concludes, from an investigation of the constraints imposed by the processing facility, that waste removal will be intermittent, requiring batch transfer over the anticipated 3 years of processing operations. Based on these reviews and conclusions, the study proposes that the acid waste be processed first and that one of the 15,000-gallon acid tanks then be used for batch feeding the neutralized waste. The proposed system would employ commercially available pumping equipment to transfer the wastes from the batch tank to processing via existing process piping. A commercially available mixed-flow pump and eight turbine pumps would homogenize the neutralized waste in conjunction with eight custom-fabricated sluicers for periodic transfer to the batch tank

  19. TMI defueling project fuel debris removal system

    International Nuclear Information System (INIS)

    Burdge, B.

    1992-01-01

    The three mile Island Unit 2 (TMI-2) pressurized water reactor loss-of-coolant accident on March 28, 1979, presented the nuclear community with many challenging remediation problems; most importantly, the removal of the fission products within the reactor containment vessel. To meet this removal problem, an air-lift system (ALS) can be used to employ compressed air to produce the motive force for transporting debris. Debris is separated from the transport stream by gravity separation. The entire method does not rely on any moving parts. Full-scale testing of the ALS at the Idaho National Engineering Laboratory (INEL) has demonstrated the capability of transporting fuel debris from beneath the LCSA into a standard fuel debris bucket at a minimum rate of 230 kg/min

  20. System for removing contaminated surface layers

    International Nuclear Information System (INIS)

    Yoshikawa, Kozo.

    1987-04-01

    The object of the present invention is to offer a new type of useful decontamination system, with which the contaminated surface layers can be removed effectively by injection of such solid microparticles. Liquid carbon dioxide is passed from a liquid carbon dioxide tank via the carbon dioxide supply line into the system for injecting solid carbon dioxide particles. Part of the liquid carbon dioxide introduced into the system is converted to solid carbon dioxide particles by the temperature drop resulting from adiabatic expansion in the carbon dioxide expansion space of the injection system. The solid carbon dioxide particles reach the injection nozzle, which is connected through the expansion space. The carbon dioxide microparticles are further cooled and accelerated by nitrogen gas injected from the nitrogen gas nozzle at the tip of the nitrogen gas supply line, which is connected to a liquid nitrogen tank. The cooled and accelerated solid carbon dioxide microparticles are injected from the injection nozzle for the solid carbon dioxide and directed against the contaminated surface to be cleaned, and, as a result, the surface contamination is removed

  1. K basins sludge removal sludge pretreatment system

    International Nuclear Information System (INIS)

    Chang, H.L.

    1997-01-01

    The Spent Nuclear Fuels Program is in the process of planning activities to remove spent nuclear fuel and other materials from the 100-K Basins as a remediation effort for clean closure. The 105 K- East and K-West Basins store spent fuel, sludge, and debris. Sludge has accumulated in the 1 00 K Basins as a result of fuel oxidation and a slight amount of general debris being deposited, by settling, in the basin water. The ultimate intent in removing the sludge and fuel is to eliminate the environmental risk posed by storing fuel at the K Basins. The task for this project is to disposition specific constituents of sludge (metallic fuel) to produce a product stream through a pretreatment process that will meet the requirements, including a final particle size acceptable to the Tank Waste Remediation System (TWRS). The purpose of this task is to develop a preconceptual design package for the K Basin sludge pretreatment system. The process equipment/system is at a preconceptual stage, as shown in sketch ES-SNF-01 , while a more refined process system and material/energy balances are ongoing (all sketches are shown in Appendix C). Thus, the overall process and 0535 associated equipment have been conservatively selected and sized, respectively, to establish the cost basis and equipment layout as shown in sketches ES- SNF-02 through 08

  2. BOA: Pipe asbestos insulation removal robot system

    International Nuclear Information System (INIS)

    Schempf, H.; Bares, J.; Schnorr, W.

    1995-01-01

    The BOA system is a mobile pipe-external robotic crawler used to remotely strip and bag asbestos-containing lagging and insulation materials (ACLIM) from various diameter pipes in (primarily) industrial installations. Steam and process lines within the DOE weapons complex warrant the use of a remote device due to the high labor costs and high level of radioactive contamination, making manual removal extremely costly and highly inefficient. Currently targeted facilities for demonstration and remediation are Fernald in Ohio and Oak Ridge in Tennessee

  3. Boron Removal in Seawater Reverse Osmosis System

    KAUST Repository

    Rahmawati, Karina

    2011-07-01

    Reverse osmosis successfully proves to remove more than 99% of solute in seawater, providing fresh water supply with satisfied quality. Due to some operational constraints, however, some trace contaminants removal, such as boron, cannot be achieved in one pass system. The stringent criterion for boron from World Health Organization (WHO) and Saudi Arabia local standard (0.5 mg/l) is hardly fulfilled by single pass sea water reverse osmosis (SWRO) plants. Some design processes have been proposed to deal with boron removal, but they are not economically efficient due to high energy and chemical consumption. The objective of this study was to study boron removal by different reverse osmosis membranes in two pH conditions, with and without antiscalant addition. Thus, it was expected to observe the possibility of operating single pass system and necessity to operate two pass system using low energy membrane. Five membrane samples were obtained from two different manufacturers. Three types of feed water pH were used, pH 8, pH 10, and pH 10 with antiscalant addition. Experiment was conducted in parallel to compare membrane performance from two manufacturers. Filtration was run with fully recycle mode for three days. Sample of permeate and feed were taken every 12 hours, and analyzed for their boron and TDS concentration. Membrane samples were also tested for their surface charge. The results showed that boron rejection increases as the feed pH increases. This was caused by dissociation of boric acid to negatively charged borate ion and more negatively charged membrane surface at elevated pH which enhance boron rejection. This study found that single pass reverse osmosis system, with and without elevating the pH, may not be possible to be applied because of two reasons. First, permeate quality in term of boron, does not fulfill WHO and local Saudi Arabia regulations. Second, severe scaling occurs due to operation in alkaline condition, since Ca and Mg concentration are

  4. Residual heat removal system diagnostic advisor

    International Nuclear Information System (INIS)

    Tripp, L.

    1991-01-01

    This paper reports on the Residual Heat Removal System (RHRS) Diagnostic Advisor which is an expert system designed to alert the operators to abnormal conditions that exits in the RHRS and offer advice about the cause of the abnormal conditions. The Advisor uses a combination of rule-based and model-based diagnostic techniques to perform its functions. This diagnostic approach leads to a deeper understanding of the RHRS by the Advisor and consequently makes it more robust to unexpected conditions. The main window of the interactive graphic display is a schematic diagram of the RHRS piping system. When a conclusion about a failed component can be reached, the operator can bring up windows that describe the failure mode of the component and a brief explanation about how the Advisor arrived at its conclusion

  5. Discrete Address Beacon System (DABS) Baseline Test and Evaluation.

    Science.gov (United States)

    1980-04-01

    maturing of the DABS/Automatic Traffic Advisory and Resolution Service ( ATARS ) system concept, would require further study and test prior to issuance of...surveillance, Automatic Traffic Advisory and Resolution Service ( ATARS ) and communications capabilities required for air traffic control (ATC) in the...1980’s and 1990’s. Compatibility with ATCRBS has been emphasized to permit an extended and economical transition. The requirement for the development

  6. Contribution of BeiDou satellite system for long baseline GNSS measurement in Indonesia

    Science.gov (United States)

    Gumilar, I.; Bramanto, B.; Kuntjoro, W.; Abidin, H. Z.; Trihantoro, N. F.

    2018-05-01

    The demand for more precise positioning method using GNSS (Global Navigation Satellite System) in Indonesia continue to rise. The accuracy of GNSS positioning depends on the length of baseline and the distribution of observed satellites. BeiDou Navigation Satellite System (BDS) is a positioning system owned by China that operating in Asia-Pacific region, including Indonesia. This research aims to find out the contribution of BDS in increasing the accuracy of long baseline static positioning in Indonesia. The contributions are assessed by comparing the accuracy of measurement using only GPS (Global Positioning System) and measurement using the combination of GPS and BDS. The data used is 5 days of GPS and BDS measurement data for baseline with 120 km in length. The software used is open-source RTKLIB and commercial software Compass Solution. This research will explain in detail the contribution of BDS to the accuracy of position in long baseline static GNSS measurement.

  7. Efficient algorithm for baseline wander and powerline noise removal from ECG signals based on discrete Fourier series.

    Science.gov (United States)

    Bahaz, Mohamed; Benzid, Redha

    2018-03-01

    Electrocardiogram (ECG) signals are often contaminated with artefacts and noises which can lead to incorrect diagnosis when they are visually inspected by cardiologists. In this paper, the well-known discrete Fourier series (DFS) is re-explored and an efficient DFS-based method is proposed to reduce contribution of both baseline wander (BW) and powerline interference (PLI) noises in ECG records. In the first step, the determination of the exact number of low frequency harmonics contributing in BW is achieved. Next, the baseline drift is estimated by the sum of all associated Fourier sinusoids components. Then, the baseline shift is discarded efficiently by a subtraction of its approximated version from the original biased ECG signal. Concerning the PLI, the subtraction of the contributing harmonics calculated in the same manner reduces efficiently such type of noise. In addition of visual quality results, the proposed algorithm shows superior performance in terms of higher signal-to-noise ratio and smaller mean square error when faced to the DCT-based algorithm.

  8. Study on judgement baseline for XRF on-line detection system

    International Nuclear Information System (INIS)

    Zhang Quanshi; Bao Min

    2000-01-01

    Based on the Signal Detection Theory (SDT) and the statistics principle, the choice method of judgement baseline was studied. According to the characteristics of X-ray Fluorescence (XRF) spectra in the on-line detection system, the calculation methods for the characteristic peak of the element-tagged and background were carried out. The complex judgement baseline were rationally selected after a lot of experiments and analyzing. The operating results of near one year show that it is available

  9. Tank waste remediation system retrieval and disposal mission initial updated baseline summary

    International Nuclear Information System (INIS)

    Swita, W.R.

    1998-01-01

    This document provides a summary of the proposed Tank Waste Remediation System Retrieval and Disposal Mission Initial Updated Baseline (scope, schedule, and cost) developed to demonstrate the Tank Waste Remediation System contractor's Readiness-to-Proceed in support of the Phase 1B mission

  10. Residual Heat Removal System qualitative probabilistic safety analysis before and after auto closure interlock removal

    International Nuclear Information System (INIS)

    Mikulicic, V.; Simic, Z.

    1992-01-01

    The analysis evaluates the consequences of the removal of the auto closure interlock (ACI) on the Residual Heat Removal System (RHRS) suction/isolation valves at the nuclear power plant. The deletion of the RHRS ACI is in part based on a probabilistic safety analysis (PSA) which justifies the removal based on a criterion of increased availability and reliability. Three different areas to be examined in PSA: the likelihood of an interfacing system LOCA; RHRS availability and reliability; and low temperature overpressurization control. The paper emphasizes particularly the RHRS unavailability and reliability evaluation utilizing the current control circuitry configuration and then with the proposed modification to the control circuitry. (author)

  11. Biological Nutrient Removal in Compact Biofilm Systems

    NARCIS (Netherlands)

    Bassin, J.P.

    2012-01-01

    The removal of nutrients such as nitrogen and phosphorus from both domestic and industrial wastewaters is imperative since they potentially harm the environment. One of the main consequences of excessive availability of nitrogen and phosphorus in aquatic ecosystems (freshwater, marine and estuarine)

  12. Biological Nutrient Removal in Compact Biofilm Systems

    OpenAIRE

    Bassin, J.P.

    2012-01-01

    The removal of nutrients such as nitrogen and phosphorus from both domestic and industrial wastewaters is imperative since they potentially harm the environment. One of the main consequences of excessive availability of nitrogen and phosphorus in aquatic ecosystems (freshwater, marine and estuarine) is the overgrowth of algae and other aquatic plants, a phenomenon designated as eutrophication. Algae and aquatic plants induce depletion of oxygen in water basins, resulting in massive death of e...

  13. Baseline Configuration of the Cryogenic System for the International Linear Collider

    CERN Document Server

    Casas-Cubillos, J; Claudet, S; Ganni, R; Klebaner, A; Parma, V; Peterson, T; Riddone, G; Rode, C; Rousset, B; Serio, L; Tavian, L; Theilacker, J; Vullierme, B; Van Weelderen, R; Weisend, J

    2007-01-01

    The paper discusses the main constraints and boundary conditions and describes the baseline configuration of the International Linear Collider (ILC) cryogenic system. The cryogenic layout, architecture and the cooling principle are presented. The paper addresses a plan for study and development required to demonstrate and improve the performance, to reduce cost and to attain the desired reliability.

  14. Pollutant removal in subsurface wastewater infiltration systems with ...

    African Journals Online (AJOL)

    Pollutant removal in subsurface wastewater infiltration systems with/without intermittent ... Water SA. Journal Home · ABOUT THIS JOURNAL · Advanced Search ... wastewater infiltration systems (SWISs) with and without intermittent aeration, ...

  15. Software Configuration Management Plan for the Sodium Removal System

    International Nuclear Information System (INIS)

    HILL, L.F.

    2000-01-01

    This document establishers the Software Configuration Management Plan (SCMP) for the software associated with the control system of the Sodium Removal System (SRS) located in the Interim Examination and Maintenance (IEM Cell) Facility of the FFTF Flux Test

  16. IVO's nuclide removal system takes to the road

    International Nuclear Information System (INIS)

    Tusa, E.H.

    1995-01-01

    The successful and routine use of IVO's treatment system for the removal of cesium from the evaporator concentrates at the Loviisa WER plant in Finland is described. The system uses a granular inorganic hexacyanoferate-based ion exchanger to separate cesium from liquid radioactive wastes. The compactness of the original systems at Loviisa suggested the development of a transportable unit. A combined nuclide removal system was created which included a highly efficient ultrafiltration unit to separate nearly all particulate material carrying radionuclides, as well as the cesium removal capability. A 20ft long container carrying the removal package was completed in 1994. This NUclide REmoval System (NURES) was used for the first time in January 1995 to purify liquid waste accumulating at training reactors in Estonia and has performed well. As an extension of nuclide removal, a process has been created to recover boron from liquid wastes. A system for boron recovery and nuclide removal has been designed for use at the Paks plant in Hungary. The removal process has been shown to improve the safety of final waste disposal compared with the alternative treatment by cementation because the cesium is very tightly bound into the ion exchange material. (UK)

  17. Microbunch preserving in-line system for an APPLE II helical radiator at the LCLS baseline

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL Project Team, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2011-05-15

    In a previous work we proposed a scheme for polarization control at the LCLS baseline, which exploited the microbunching from the planar undulator. After the baseline undulator, the electron beam is transported through a drift by a FODO focusing system, and through a short helical radiator. The microbunching structure can be preserved, and intense coherent radiation is emitted in the helical undulator at fundamental harmonic. The driving idea of this proposal is that the background linearly-polarized radiation from the baseline undulator is suppressed by spatial filtering. Filtering is achieved by letting radiation and electron beam through Be slits upstream of the helical radiator, where the radiation spot size is about ten times larger than the electron beam transverse size. Several changes considered in the present paper were made to improve the previous design. Slits are now placed immediately behind the helical radiator. The advantage is that the electron beam can be spoiled by the slits, and narrower slits width can be used for spatial filtering. Due to this fundamental reason, the present setup is shorter than the previous one. The helical radiator is now placed immediately behind the SHAB undulator. It is thus sufficient to use the existing FODO focusing system of the SHAB undulator for transporting themodulated electron beam. This paper presents complete GENESIS code calculations for the new design, starting from the baseline undulator entrance up to the helical radiator exit including the modulated electron beam transport by the SHAB FODO focusing system. (orig.)

  18. Microbunch preserving in-line system for an APPLE II helical radiator at the LCLS baseline

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2011-05-01

    In a previous work we proposed a scheme for polarization control at the LCLS baseline, which exploited the microbunching from the planar undulator. After the baseline undulator, the electron beam is transported through a drift by a FODO focusing system, and through a short helical radiator. The microbunching structure can be preserved, and intense coherent radiation is emitted in the helical undulator at fundamental harmonic. The driving idea of this proposal is that the background linearly-polarized radiation from the baseline undulator is suppressed by spatial filtering. Filtering is achieved by letting radiation and electron beam through Be slits upstream of the helical radiator, where the radiation spot size is about ten times larger than the electron beam transverse size. Several changes considered in the present paper were made to improve the previous design. Slits are now placed immediately behind the helical radiator. The advantage is that the electron beam can be spoiled by the slits, and narrower slits width can be used for spatial filtering. Due to this fundamental reason, the present setup is shorter than the previous one. The helical radiator is now placed immediately behind the SHAB undulator. It is thus sufficient to use the existing FODO focusing system of the SHAB undulator for transporting themodulated electron beam. This paper presents complete GENESIS code calculations for the new design, starting from the baseline undulator entrance up to the helical radiator exit including the modulated electron beam transport by the SHAB FODO focusing system. (orig.)

  19. High-Level software requirements specification for the TWRS controlled baseline database system

    International Nuclear Information System (INIS)

    Spencer, S.G.

    1998-01-01

    This Software Requirements Specification (SRS) is an as-built document that presents the Tank Waste Remediation System (TWRS) Controlled Baseline Database (TCBD) in its current state. It was originally known as the Performance Measurement Control System (PMCS). Conversion to the new system name has not occurred within the current production system. Therefore, for simplicity, all references to TCBD are equivalent to PMCS references. This SRS will reference the PMCS designator from this point forward to capture the as-built SRS. This SRS is written at a high-level and is intended to provide the design basis for the PMCS. The PMCS was first released as the electronic data repository for cost, schedule, and technical administrative baseline information for the TAAS Program. During its initial development, the PMCS was accepted by the customer, TARS Business Management, with no formal documentation to capture the initial requirements

  20. 324 Building liquid waste handling and removal system project plan

    Energy Technology Data Exchange (ETDEWEB)

    Ham, J.E.

    1998-07-29

    This report evaluates the modification options for handling radiological liquid waste generated during decontamination and cleanout of the 324 Building. Recent discussions indicate that the Hanford site railroad system will be closed by the end of FY 1998 necessitating the need for an alternate transfer method. The issue of handling of Radioactive Liquid Waste (RLW) from the 324 Building (assuming the 340 Facility is not available to accept the RLW) has been examined in at least two earlier engineering studies (Parsons 1997a and Hobart 1997). Each study identified a similar preferred alternative that included modifying the 324 Building RLWS to allow load-out of wastewater to a truck tanker, while making maximum use of existing piping, tanks, instrumentation, controls and other features to minimize costs and physical changes to the building. This alternative is accepted as the basis for further discussion presented in this study. The goal of this engineering study is to verify the path forward presented in the previous studies and assure that the selected alternative satisfies the 324 Building deactivation goals and objectives as currently described in the project management plan. This study will also evaluate options available to implement the preferred alternative and select the preferred option for implementation of the entire system. Items requiring further examination will also be identified. Finally, the study will provide a conceptual design, schedule and cost estimate for the required modifications to the 324 Building to allow removal of RLW. Attachment 5 is an excerpt from the project baseline schedule found in the Project Management Plan.

  1. Evaluation of improved techniques for the removal of 90Sr and 137Cs from process wastewater and groundwater: Chabazite zeolite baseline study

    International Nuclear Information System (INIS)

    Bostick, D.T.; Arnold, W.D. Jr.; Taylor, P.A.; McTaggart, D.R.; Burgess, M.W.; Guo, B.

    1995-04-01

    Standard waste treatment procedures for the removal of 90 Sr and 137 Cs from contaminated groundwater and process wastewaters generate large volumes of secondary contaminated wastes. Several new sorbent materials, ion exchangers, and other processes hold the promise of treating large volumes of contaminated water while minimizing the generation of secondary low-level radioactive wastes. As part of the Efficient Separations/Processes-Integrated Program (ESPIP), these new treatment techniques will be compared with standard processes to define their effectiveness for the removal of radioactive strontium (Sr) and cesium (Cs), as well as to gauge the quantity of secondary radioactive waste generated by the new processes. This report summarizes the efforts made to design standardized testing procedures to evaluate the sorption characteristics of a baseline wastewater treatment technique. Definition of the experimental procedures, as well as a summary of the benchmark sorption technique, will provide the framework with which to compare newly evolving treatment technologies. Accomplishments include selecting the feed strewn to the Process Waste Treatment Plant (PWTP) at Oak Ridge National Laboratory as representative of the prototypical contaminated wastewater of many DOE sites. Samples from the PWTP feed stream were collected and analyzed for metals, anions, total Sr and Cs, radioactive Sr and Cs, alkalinity, pH, and density. The cumulative sample data were used to formulate a simulant that will be used as a standard waste surrogate for comparative testing of selected treatment methods

  2. Fast removal of oxygen from biological systems

    International Nuclear Information System (INIS)

    Dewey, D.L.; Michael, B.D.

    1975-01-01

    Reference is made to the fact that if radiation is given at a high enough dose rate, the biological effect of oxygen is less than at low dose rates. Examples are given of 'break-point' experiments showing the effect. It is stated that the rapid removal of a substance by radiation is not confined to oxygen: the only criterion required to demonstrate the effect is that the chemical causes a measurable sensitization or protection at a concentration small enough so that it can be depleted at a relatively low dose of radiation. Sufficient confidence is now placed in the effect that it can be used the other way round; that is, to measure the position of the break-point and from this measurement determine the oxygen concentration at the target site at the instant before irradiation. Examples are given of the use of the high dose rate technique for measuring the oxygen concentration inside mammalian cells (Chinese hamster cells). The effects of partial pressures of inert gases, and the effect of elevated gas pressures, are discussed. (U.K.)

  3. Tank waste remediation system baseline tank waste inventory estimates for fiscal year 1995

    International Nuclear Information System (INIS)

    Shelton, L.W.

    1996-01-01

    A set of tank-by-tank waste inventories is derived from historical waste models, flowsheet records, and analytical data to support the Tank Waste Remediation System flowsheet and retrieval sequence studies. Enabling assumptions and methodologies used to develop the inventories are discussed. These provisional inventories conform to previously established baseline inventories and are meant to serve as an interim basis until standardized inventory estimates are made available

  4. Baseline Design Compliance Matrix for the Rotary Mode Core Sampling System

    International Nuclear Information System (INIS)

    LECHELT, J.A.

    2000-01-01

    The purpose of the design compliance matrix (DCM) is to provide a single-source document of all design requirements associated with the fifteen subsystems that make up the rotary mode core sampling (RMCS) system. It is intended to be the baseline requirement document for the RMCS system and to be used in governing all future design and design verification activities associated with it. This document is the DCM for the RMCS system used on Hanford single-shell radioactive waste storage tanks. This includes the Exhauster System, Rotary Mode Core Sample Trucks, Universal Sampling System, Diesel Generator System, Distribution Trailer, X-Ray Cart System, Breathing Air Compressor, Nitrogen Supply Trailer, Casks and Cask Truck, Service Trailer, Core Sampling Riser Equipment, Core Sampling Support Trucks, Foot Clamp, Ramps and Platforms and Purged Camera System. Excluded items are tools such as light plants and light stands. Other items such as the breather inlet filter are covered by a different design baseline. In this case, the inlet breather filter is covered by the Tank Farms Design Compliance Matrix

  5. Association of baseline bleeding pattern on amenorrhea with levonorgestrel intrauterine system use.

    Science.gov (United States)

    Mejia, Manuela; McNicholas, Colleen; Madden, Tessa; Peipert, Jeffrey F

    2016-11-01

    This study aims to evaluate the effect of baseline bleeding patterns on rates of amenorrhea reported at 12 months in levonorgestrel (LNG) 52 mg intrauterine system (IUS) users. We also assessed the effect of baseline bleeding patterns at 3 and 6 months postinsertion. In this secondary analysis of the Contraceptive CHOICE Project, we included participants who had an LNG-IUS inserted within 1 month of enrollment and continued use for 12 months. Using 12-month telephone survey data, we defined amenorrhea at 12 months of use as no bleeding or spotting during the previous 6 months. We used chi-square and multivariable logistic regression to assess the association of baseline bleeding pattern with amenorrhea while controlling for confounding variables. Of 1802 continuous 12-month LNG-IUS users, amenorrhea was reported by 4.9%, 14.8% and 15.4% of participants at 3, 6 and 12 months, receptively. Participants with light baseline bleeding or short duration of flow reported higher rates of amenorrhea at 3 and 6 months postinsertion (pamenorrhea at 3 and 6 months (pamenorrhea at 12 months than those who reported moderate bleeding (OR adj , 0.36; 95% CI, 0.16-0.69). Women with heavier menstrual bleeding are less likely than women with moderate flow to report amenorrhea following 12 months of LNG-IUS use. Baseline heavy menstrual flow reduces the likelihood of amenorrhea with LNG-IUS use, information that could impact contraceptive counseling. Anticipatory counseling can improve method satisfaction and continuation, an important strategy to continue to reduce unintended pregnancy and abortion rates. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Controlled biomass removal - the key parameter to achieve enhanced biological phosphorus removal in biofilm systems

    DEFF Research Database (Denmark)

    Morgenroth, E.

    1999-01-01

    the influence of the following processes on EBPR in biofilms was evaluated: (1) mass transfer limitation for oxygen (2) mass transfer limitation for organic substrate, (3) lack of controlled removal of biomass from the system. It was shown that mass transfer of soluble components (oxygen and organic substrate...

  7. Data Management Guide: Integrated Baseline System (IBS). Version 2.1

    Energy Technology Data Exchange (ETDEWEB)

    Bower, J.C. [Bower Software Services, Kennewick, Washington (United States); Burford, M.J.; Downing, T.R.; Moise, M.C.; Williams, J.R. [Pacific Northwest Lab., Richland, WA (United States)

    1995-01-01

    The Integrated Baseline System (IBS) is an emergency management planning and analysis tool that is being developed under the direction of the US Army Nuclear and Chemical Agency (USANCA). The IBS Data Management Guide provides the background, as well as the operations and procedures needed to generate and maintain a site-specific map database. Data and system managers use this guide to manage the data files and database that support the administrative, user-environment, database management, and operational capabilities of the IBS. This document provides a description of the data files and structures necessary for running the IBS software and using the site map database.

  8. Passive Decay Heat Removal System for Micro Modular Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jangsik; Lee, Jeong Ik; Jeong, Yong Hoon [KAIST, Daejeon (Korea, Republic of)

    2015-10-15

    Dry cooling system is applied as waste heat removal system therefore it is able to consider wide construction site. Schematic figure of the reactor is shown in Fig. 1. In safety features, the reactor has double containment and passive decay heat removal (PDHR) system. The double containment prevents leakage from reactor coolant system to be emitted into environment. The passive decay heat removal system copes with design basis accidents (DBAs). Micros Modular Reactor (MMR) which has been being developed in KAIST is S-CO{sub 2} gas cooled reactor and shows many advantages. The S-CO{sub 2} power cycle reduces size of compressor, and it makes small size of power plant enough to be transported by trailer.The passive residual heat removal system is designed and thermal hydraulic (TH) analysis on coolant system is accomplished. In this research, the design process and TH analysis results are presented. PDHR system is designed for MMR and coolant system with the PDHR system is analyzed by MARS-KS code. Conservative assumptions are applied and the results show that PDHR system keeps coolant system under the design limitation.

  9. Operability test procedure [Tank] 241-SY-101 equipment removal system

    International Nuclear Information System (INIS)

    Mast, J.C.

    1994-01-01

    The 241-SY-101 equipment removal system (ERS) consists of components, equipment, instrumentation and procedures that will provide the means to disconnect, retrieve, contain, load and transport the Mitigation Pump Assembly (MPA) from waste Tank 241-SY-101 to the Central Waste Complex (CWC). The Operability Test Procedure (OTP) will test the interfaces between ERS components and will rehearse the procedure for MPA removal and transportation to the extent they can be mocked-up at the CTF (Cold Test Facility). At the conclusion of the OTP, the ERS components and equipment will be removed from the CTF, entered into the Component Based Recall System (CBRS), and stored until needed for actual MPA removal and transportation

  10. Performance of the prism reactor's passive decay heat removal system

    International Nuclear Information System (INIS)

    Magee, P.M.; Hunsbedt, A.

    1989-01-01

    The PRISM modular reactor concept has a totally passive safety-grade decay heat removal system referred to as the Reactor Vessel Auxiliary Cooling System (RVACS) that rejects heat from the reactor by radiation and natural convection of air. The system is inherently reliable and is not subject to the failure modes commonly associated with active cooling systems. The thermal performance of RVACS exceeds requirements and significant thermal margins exist. RVACS has been shown to perform its function under many postulated accident conditions. The PRISM power plant is equipped with three methods for shutdown: condenser cooling in conjunction with intermediate sodium and steam generator systems, and auxiliary cooling system (ACS) which removes heat from the steam generator by natural convection of air and transport of heat from the core by natural convection in the primary and intermediate systems, and a safety- grade reactor vessel auxiliary cooling system (RVACS) which removes heat passively from the reactor containment vessel by natural convection of air. The combination of one active and two passive systems provides a highly reliable and economical shutdown heat removal system. This paper provides a summary of the RVACS thermal performance for expected operating conditions and postulated accident events. The supporting experimental work, which substantiates the performance predictions, is also summarized

  11. Tank waste remediation system retrieval and disposal mission initial updated baseline summary

    International Nuclear Information System (INIS)

    Swita, W.R.

    1998-01-01

    This document provides a summary of the Tank Waste Remediation System (TWRS) Retrieval and Disposal Mission Initial Updated Baseline (scope, schedule, and cost), developed to demonstrate Readiness-to-Proceed (RTP) in support of the TWRS Phase 1B mission. This Updated Baseline is the proposed TWRS plan to execute and measure the mission work scope. This document and other supporting data demonstrate that the TWRS Project Hanford Management Contract (PHMC) team is prepared to fully support Phase 1B by executing the following scope, schedule, and cost baseline activities: Deliver the specified initial low-activity waste (LAW) and high-level waste (HLW) feed batches in a consistent, safe, and reliable manner to support private contractors' operations starting in June 2002; Deliver specified subsequent LAW and HLW feed batches during Phase 1B in a consistent, safe, and reliable manner; Provide for the interim storage of immobilized HLW (IHLW) products and the disposal of immobilized LAW (ILAW) products generated by the private contractors; Provide for disposal of byproduct wastes generated by the private contractors; and Provide the infrastructure to support construction and operations of the private contractors' facilities

  12. 48 CFR 352.234-1 - Notice of earned value management system-pre-award Integrated Baseline Review.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Notice of earned value management system-pre-award Integrated Baseline Review. 352.234-1 Section 352.234-1 Federal Acquisition... provision: Notice of Earned Value Management System—Pre-Award Integrated Baseline Review (October 2008) The...

  13. 48 CFR 352.234-2 - Notice of earned value management system-post-award Integrated Baseline Review.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Notice of earned value management system-post-award Integrated Baseline Review. 352.234-2 Section 352.234-2 Federal Acquisition... provision: Notice of Earned Value Management System—Post-Award Integrated Baseline Review (October 2008) (a...

  14. Shear rate normalization is not essential for removing the dependency of flow-mediated dilation on baseline artery diameter: past research revisited

    International Nuclear Information System (INIS)

    Atkinson, Greg

    2014-01-01

    A ratio index (FMD%) is used ubiquitously to scale (by simple division) brachial artery flow-mediated dilation (D diff ) in direct proportion to baseline diameter (D base ). It is now known that D diff is inversely proportional to D base rendering FMD% wholly inappropriate. Consequently, FMD% is still substantially dependent on D base . Although this problem is grounded in statistics, normalization of FMD% for the change in arterial shear rate (ΔSR) has been proposed to remove this D base -dependency. It was hypothesized that, if the flow-mediated response is scaled properly to D base in the first place, shear rate normalization would not be needed to remove D base -dependency. Dedicated software (Digitizelt) was employed to extract the data from a seminal study on FMD% normalization. The underlying allometric relationship between D base and peak diameter (D peak ) was described. The re-analyses revealed that the absolute change in arterial diameter was strongly inversely proportional to D base (r= − 0.7, P < 0.0005). The allometric exponent for the D base –D peak relationship was 0.82 (95% CI: 0.78–0.86) rather than the value of 1 needed for appropriate use of FMD%. The allometric approach completely eliminated the originally reported dependency on D base without any need for ΔSR normalization (r=0.0, P=0.96). The correlation between ΔSR and FMD% reduced from 0.69 to 0.37, when adjusted for D base . In conclusion, this new re-analysis of data from an influential study demonstrates that the FMD%–D base correlation is caused by the inappropriate size-scaling properties of FMD% itself. Removal of D base -dependency via FMD%/ΔSR normalization is not essential at all if allometric scaling is applied to isolate the flow-mediated response in the first place. Consequently, the influence of ΔSR on this properly scaled response can also be isolated and quantified accurately without the confounding influence of D base . (paper)

  15. Baselining the New GSFC Information Systems Center: The Foundation for Verifiable Software Process Improvement

    Science.gov (United States)

    Parra, A.; Schultz, D.; Boger, J.; Condon, S.; Webby, R.; Morisio, M.; Yakimovich, D.; Carver, J.; Stark, M.; Basili, V.; hide

    1999-01-01

    This paper describes a study performed at the Information System Center (ISC) in NASA Goddard Space Flight Center. The ISC was set up in 1998 as a core competence center in information technology. The study aims at characterizing people, processes and products of the new center, to provide a basis for proposing improvement actions and comparing the center before and after these actions have been performed. The paper presents the ISC, goals and methods of the study, results and suggestions for improvement, through the branch-level portion of this baselining effort.

  16. BILLIARDS: Baseline Instrumented Lithology Lander, Inspector and Asteroid Redirection Demonstration System

    Science.gov (United States)

    Marcus, Matthew; Sloane, Joshua; Ortiz, Oliver; Barbee, Brent

    2015-01-01

    BILLIARDS Baseline Instrumented Lithology Lander, Inspector, and Asteroid Redirection Demonstration System Proposed demonstration mission for Billiard-Ball concept Select asteroid pair with natural close approach to minimize cost and complexity Primary Objectives Rendezvous with a small (10m), near Earth (alpha) asteroid Maneuver the alpha asteroid to a collision with a 100m (beta) asteroid Produce a detectable deflection or disruption of the beta asteroid Secondary objectives Contribute knowledge of asteroid composition and characteristics Contribute knowledge of small-body formation Opportunity for international collaboration

  17. A novel variable baseline visibility detection system and its measurement method

    Science.gov (United States)

    Li, Meng; Jiang, Li-hui; Xiong, Xing-long; Zhang, Guizhong; Yao, JianQuan

    2017-10-01

    As an important meteorological observation instrument, the visibility meter can ensure the safety of traffic operation. However, due to the optical system contamination as well as sample error, the accuracy and stability of the equipment are difficult to meet the requirement in the low-visibility environment. To settle this matter, a novel measurement equipment was designed based upon multiple baseline, which essentially acts as an atmospheric transmission meter with movable optical receiver, applying weighted least square method to process signal. Theoretical analysis and experiments in real atmosphere environment support this technique.

  18. Valve arrangement for a nuclear plant residual heat removal system

    International Nuclear Information System (INIS)

    Fidler, G.L.; Hill, R.A.; Carrera, J.P.

    1978-01-01

    Disclosed is an improved valve arrangement for a two-train Residual Heat Removal System (RHRS) of a nuclear reactor plant which ensures operational integrity of the system under single failure circumstances including loss of one of two electrical power sources

  19. Control of the ASTRA decay heat removal system

    International Nuclear Information System (INIS)

    Nedelik, A.

    1982-11-01

    To ensure a minimum of core cooling even under severest accident conditions (loss of reactor pool water) a core spray system for decay heat removal has been installed at the ASTRA-reactor. The automatic and manual control of the system, its power supply and test procedures are shortly described. (Author)

  20. Baseline restoration using current conveyors

    International Nuclear Information System (INIS)

    Morgado, A.M.L.S.; Simoes, J.B.; Correia, C.M.

    1996-01-01

    A good performance of high resolution nuclear spectrometry systems, at high pulse rates, demands restoration of baseline between pulses, in order to remove rate dependent baseline shifts. This restoration is performed by circuits named baseline restorers (BLRs) which also remove low frequency noise, such as power supply hum and detector microphonics. This paper presents simple circuits for baseline restoration based on a commercial current conveyor (CCII01). Tests were performed, on two circuits, with periodic trapezoidal shaped pulses in order to measure the baseline restoration for several pulse rates and restorer duty cycles. For the current conveyor based Robinson restorer, the peak shift was less than 10 mV, for duty cycles up to 60%, at high pulse rates. Duty cycles up to 80% were also tested, being the maximum peak shift 21 mV. The peak shift for the current conveyor based Grubic restorer was also measured. The maximum value found was 30 mV at 82% duty cycle. Keeping the duty cycle below 60% improves greatly the restorer performance. The ability of both baseline restorer architectures to reject low frequency modulation is also measured, with good results on both circuits

  1. CPP-603 Chloride Removal System Decontamination and Decommissioning

    International Nuclear Information System (INIS)

    Moser, C.L.

    1993-02-01

    The CPP-603 (annex) Chloride Removal System (CRS) Decontamination and Decommissioning (D ampersand D) Project is described in this report. The CRS was used for removing Chloride ions and other contaminants that were suspended in the waters of the underwater fuel storage basins in the CPP-603 Fuel Receiving and Storage Facility (FRSF) from 1975 to 1981. The Environmental Checklist and related documents, facility characterization, decision analysis', and D ampersand D plans' were prepared in 1991. Physical D ampersand D activities were begun in mid summer of 1992 and were completed by the end of November 1992. All process equipment and electrical equipment were removed from the annex following accepted asbestos and radiological contamination removal practices. The D ampersand D activities were performed in a manner such that no radiological health or safety hazard to the public or to personnel at the Idaho National Engineering Laboratory (INEL) occurred

  2. Debris Removal Project K West Canister Cleaning System Performance Specification

    International Nuclear Information System (INIS)

    FARWICK, C.C.

    1999-01-01

    Approximately 2,300 metric tons Spent Nuclear Fuel (SNF) are currently stored within two water filled pools, the 105 K East (KE) fuel storage basin and the 105 K West (KW) fuel storage basin, at the U.S. Department of Energy, Richland Operations Office (RL). The SNF Project is responsible for operation of the K Basins and for the materials within them. A subproject to the SNF Project is the Debris Removal Subproject, which is responsible for removal of empty canisters and lids from the basins. Design criteria for a Canister Cleaning System to be installed in the KW Basin. This documents the requirements for design and installation of the system

  3. A review of virus removal in wastewater treatment pond systems.

    Science.gov (United States)

    Verbyla, Matthew E; Mihelcic, James R

    2015-03-15

    Wastewater treatment ponds (lagoons) are one of the most common types of technologies used for wastewater management worldwide, especially in small cities and towns. They are particularly well-suited for systems where the effluent is reused for irrigation. However, the efficiency of virus removal in wastewater treatment pond systems is not very well understood. The main objective of this paper is to critically review the major findings related to virus removal in wastewater treatment pond systems and to statistically analyze results reported in the literature from field studies on virus removal in these systems. A comprehensive analysis of virus removal reported in the literature from 71 different wastewater treatment pond systems reveals only a weak to moderate correlation of virus removal with theoretical hydraulic retention time. On average, one log10 reduction of viruses was achieved for every 14.5-20.9 days of retention, but the 95th percentile value of the data analyzed was 54 days. The mechanisms responsible for virus removal in wastewater treatment ponds were also reviewed. One recent finding is that sedimentation may not be a significant virus removal mechanism in some wastewater ponds. Recent research has also revealed that direct and indirect sunlight-mediated mechanisms are not only dependent on pond water chemistry and optics, but also on the characteristics of the virus and its genome. MS2 coliphage is considered to be the best surrogate for studying sunlight disinfection in ponds. The interaction of viruses with particles, with other microorganisms, and with macroinvertebrates in wastewater treatment ponds has not been extensively studied. It is also unclear whether virus internalization by higher trophic-level organisms has a protective or a detrimental effect on virus viability and transport in pond systems. Similarly, the impact of virus-particle associations on sunlight disinfection in ponds is not well understood. Future research should focus on

  4. After-heat removing system in FBR type reactor

    International Nuclear Information System (INIS)

    Ohashi, Yukio.

    1990-01-01

    The after-heat removing system of the present invention removes the after heat generated in a reactor core without using dynamic equipments such as pumps or blowers. There are disposed a first heat exchanger for heating a heat medium by the heat in a reactor container and a second heat exchanger situated above the first heat exchanger for spontaneously air-cooling the heat medium. Recycling pipeways connect the first and the second heat exchangers to form a recycling path for the heat medium. Then, since the second heat exchanger for spontaneously air-cooling the heat medium is disposed above the first heat exchanger and they are connected by the recycling pipeways, the heat medium can be circulated spontaneously. Accordingly, dynamic equipments such as pumps or blowers are no more necessary. As a result, the after-heat removing system of the FBR type reactor of excellent safety and reliability can be obtained. (I.S.)

  5. Water removal from a dry barrier cover system

    International Nuclear Information System (INIS)

    Stormont, J.C.; Ankeny, M.D.; Tansey, M.K.

    1994-01-01

    The results of the numerical simulations reveal that horizontal air flow through the coarse with reasonable pressure gradients can remove large quantities of water from the cover system. Initially, the water removal from the cover system is dominated by the evaporation and advection of water vapor out of the coarse layer. Once the coarse layer is dry, removal of water by evaporation near the fine/coarse layer interface reduces the local water content and water potential, and water moves toward the fine-coarse layer interface and becomes available for evaporation. This result is important in that it suggests the fine layer water content may be moderated by air flow in the coarse layer. Incorporating diffusion of water vapor from the fine layer into the coarse layer substantially increases the water movement out of the fine layer

  6. Excessive heat removal due to feedwater system malfunction

    International Nuclear Information System (INIS)

    Beader, D.; Peterlin, G.

    1986-01-01

    Excessive heat removal transient of the Krsko Nuclear Power Plant, caused by steam generators feedwater system malfunctions was simulated by RELAP5/MOD1 computer code. The results are increase of power and reactor scram caused by high-high steam generator level. (author)

  7. ASBESTOS PIPE-INSULATION REMOVAL ROBOT SYSTEM; FINAL

    International Nuclear Information System (INIS)

    Unknown

    2000-01-01

    This final topical report details the development, experimentation and field-testing activities for a robotic asbestos pipe-insulation removal robot system developed for use within the DOE's weapon complex as part of their ER and WM program, as well as in industrial abatement. The engineering development, regulatory compliance, cost-benefit and field-trial experiences gathered through this program are summarized

  8. Designing Bioretention Systems to Improve Nitrogen Removal - poster

    Science.gov (United States)

    Rain gardens, also referred to as bioretention systems, are designed primarily to infiltrate stormwater flow and reduce surface runoff and peak flows to receiving streams. Additionally, they are known to remove stressors from urban stormwater runoff, including oil and grease, pho...

  9. A removable optical sealing system for application to international safeguards

    International Nuclear Information System (INIS)

    Martin, R.E.

    1985-06-01

    A removable, optically verifiable sealing system for CANDU spent fuel storage facilities has been developed. The seal is based on the use of unique crystal patterns formed in a pure metal identity/integrity element and has been designed for easy installation and removal using simple tooling. Since the seal is optically verified, a wide range of commercial instruments, including those in use by the IAEA, can be used to verify it. Futhermore, optical verification allows the level of scrutiny to be matched with the degree of confidence required to be confident that spent fuel has not been diverted

  10. BOA: Pipe-asbestos insulation removal robot system

    International Nuclear Information System (INIS)

    Schempf, H.; Bares, J.; Mutschler, E.

    1995-01-01

    This paper describes the BOA system, a mobile pipe-external crawler used to remotely strip and bag (possibly contaminated) asbestos-containing lagging and insulation materials (ACLIM) from various diameter pipes in (primarily) industrial installations across the DOE weapons complex. The mechanical removal of ACLIM is very cost-effective due to the relatively low productivity and high cost involved in human removal scenarios. BOA, a mechanical system capable of removing most forms of lagging (paper, plaster, aluminum sheet, clamps, screws and chicken-wire), and insulation (paper, tar, asbestos fiber, mag-block) uses a circular cutter and compression paddles to cut and strip the insulation off the pipe through compression, while a HEPA-filter and encapsulant system maintain a certifiable vacuum and moisture content inside the system and on the pipe, respectively. The crawler system has been built and is currently undergoing testing. Key design parameters and performance parameters are developed and used in performance testing. Since the current system is a testbed, we also discuss future enhancements and outline two deployment scenarios (robotic and manual) for the final system to be designed and completed by the end of FY '95. An on-site demonstration is currently planned for Fernald in Ohio and Oak Ridge in Tennessee

  11. Can a safeguards accountancy system really detect an unauthorized removal

    International Nuclear Information System (INIS)

    Ehinger, M.H.; Ellis, J.H.

    1981-11-01

    Theoretical investigations and system studies indicate safeguards material balance data from reprocessing plants can be used to detect unauthorized removals. Plant systems have been modeled and simulated data used to demonstrate the techniques. But how sensitive are the techniques when used with actual plant data. What is the effect of safeguards applications on plant operability. Can safeguards be acceptable to plant operators, and are there any benefits to be derived. The Barnwell Nuclear Fuel Plant (BNFP) has been devoted to answering these and other questions over the past several years. A computerized system of near-real-time accounting and in-process inventory has been implemented and demonstrated during actual plant test runs. Measured inventories and hourly material balance closures have been made to assess safeguards in an operating plant application. The tests have culminated in actual removals of material from the operating plant to investigate the response and measure the sensitivity of the safeguards and data evaluation system

  12. Development of contaminated concrete removing system 'Clean cut method'

    International Nuclear Information System (INIS)

    Kinoshita, Takehiko; Tanaka, Tsutomu; Funakawa, Naoyoshi; Idemura, Hajime; Sakashita, Fumio; Tajitsu, Yoshiteru

    1989-01-01

    In the case of decommissioning nuclear facilities such as nuclear power stations, nuclear fuel facilities and RI handling facilities and carrying out reconstruction works, if there is radioactive contamination on the surfaces of concrete structures such as the floors and walls of the buildings for nuclear facilities, it must be removed. Since concrete is porous, contamination infiltrates into the inside of concrete, and the wiping of surfaces only or chemical decontamination cannot remove it, therefore in most cases, contaminated concrete must be removed. The removal of concrete surfaces has been carried out with chipping hammers, grinders and so on, but many problems arise due to it. In order to solve these problems, the mechanical cutting method was newly devised, and clean cut method (CCRS) was completed. The depth of cutting from concrete surface is set beforehand, and the part to be removed is accurately cut, at the same time, the concrete powder generated is collected nearly perfectly, and recovered into a drum. The outline of the method and the constitution of the system, the features of the clean cut method, the development of the technology for cutting concrete and the technology for recovering concrete powder, and the test of verifying decontamination are reported. (K.I.)

  13. A Baseline Patient Model to Support Testing of Medical Cyber-Physical Systems.

    Science.gov (United States)

    Silva, Lenardo C; Perkusich, Mirko; Almeida, Hyggo O; Perkusich, Angelo; Lima, Mateus A M; Gorgônio, Kyller C

    2015-01-01

    Medical Cyber-Physical Systems (MCPS) are currently a trending topic of research. The main challenges are related to the integration and interoperability of connected medical devices, patient safety, physiologic closed-loop control, and the verification and validation of these systems. In this paper, we focus on patient safety and MCPS validation. We present a formal patient model to be used in health care systems validation without jeopardizing the patient's health. To determine the basic patient conditions, our model considers the four main vital signs: heart rate, respiratory rate, blood pressure and body temperature. To generate the vital signs we used regression models based on statistical analysis of a clinical database. Our solution should be used as a starting point for a behavioral patient model and adapted to specific clinical scenarios. We present the modeling process of the baseline patient model and show its evaluation. The conception process may be used to build different patient models. The results show the feasibility of the proposed model as an alternative to the immediate need for clinical trials to test these medical systems.

  14. A decay heat removal system requiring no external energy

    International Nuclear Information System (INIS)

    Costes, D.; Fermandjian, J.

    1983-12-01

    A new Decay heat Removal System is described for PWR's with dry containment, i.e. a containment building which encloses no permanent reserve of cooling water. This new system is intended to provide a high level of safety since it uses no external energy, but only the thermodynamic energy of the air-steam-liquid water mixture generated in the containment after the failure of the primary circuit (''LOCA'') or of the secondary circuit. Thermodynamics of the system is evaluated first: after some design considerations, the use of the system for protecting actual PWR's is addressed

  15. An innovative pool with a passive heat removal system

    International Nuclear Information System (INIS)

    Vitale Di Maio, Damiano; Naviglio, Antonio; Giannetti, Fabio; Manni, Fabio

    2012-01-01

    Heat removal systems are of primary importance in several industrial processes. As heat sink, a water pool or atmospheric air may be selected. The first solution takes advantage of high heat transfer coefficient with water but it requires active systems to maintain a constant water level; the second solution takes benefit from the unlimited heat removal capacity by air, but it requires a larger heat exchanger to compensate the lower heat transfer coefficient. In NPPs (nuclear power plants) during a nuclear reactor shutdown, as well as in some chemical plants to control runaway reactions, it is possible to use an innovative heat sink that joins the advantages of the two previous solutions. This solution is based on a special heat exchanger submerged in a water pool designed so that when heat removal is requested, active systems are not required to maintain the water level; due to the special design, when the pool is empty, atmospheric air becomes the only heat sink. The special heat exchanger design allows to have a heat exchanger without being oversized and to have a system able to operate for unlimited period without external interventions. This innovative system provides an economic advantage as well as enhanced safety features.

  16. Removal of Shippingport Station primary system components and piping

    International Nuclear Information System (INIS)

    LaGuardia, T.S.; Lipsett, S.M.

    1987-01-01

    The dismantling workscope for the Shippingport Station Decommissioning Project was divided into subtasks to permit the work to be subcontracted to the maximum extent practicable. Major subtasks were identified and described by Activity specifications which could then be grouped into logical work packages to be put out for bid. Two of the largest dismantling work packages, removal of piping and components, were grouped together and designated as Activity Specifications 4 and 5. TLG Services, Inc. and Cleveland Wrecking Company formed a Joint Venture to perform this work during a two-year period at a cost of approximately $7 million. The major portions of this dismantling workscope are described. The primary system components within this workscope consist of the stainless steel reactor coolant piping, check valves, reactor coolant pumps, steam generators, and reactor purification demineralizers and coolers. The work performed, the heavy rigging preparations and procedures, the cutting tools used, component draining/capping techniques to prevent spills, contamination containment, airborne control techniques, and lessons learned during the removal of these primary system components are described. Summaries of crew size and composition, labor hours, duration hours and radiation exposure to workers are provided and discussed briefly. The successful completion of this work is evidence of the engineering, planning, equipment, materials and labor pool available to remove large, radioactively contaminated components safely. This experience will help decommissioning planners to prepare for the removal of reactor components in future decommissioning

  17. Effectiveness of a simple and real-time baseline shift monitoring system during stereotactic body radiation therapy of lung tumors.

    Science.gov (United States)

    Uchida, Yukihiro; Tachibana, Hidenobu; Kamei, Yoshiyuki; Kashihara, Kenichi

    2017-11-01

    This study aimed to clinically validate a simple real-time baseline shift monitoring system in a prospective study of consecutive patients undergoing stereotactic body radiation therapy (SBRT) of lung tumors, and to investigate baseline shift due to intrafraction motion of the patient's body during lung SBRT. Ten consecutive patients with peripheral lung tumors were treated by SBRT consisting of four fractions of 12 Gy each, with a total dose of 48 Gy. During treatment, each patient's geometric displacement in the anterior-posterior and left-right directions (the baseline shift) was measured using a real-time monitoring webcam system. Displacement between the start and end of treatment was measured using an X-ray fluoroscopic imaging system. The displacement measurements of the two systems were compared, and the measurements of baseline shift acquired by the monitoring system during treatment were analyzed for all patients. There was no significant deviation between the monitoring system and the X-ray imaging system, with the accuracy of measurement being within 1 mm. Measurements using the monitoring system showed that 7 min of treatment generated displacements of more than 1 mm in 50% of the patients. Baseline shift of a patient's body may be measured accurately in real time, using a monitoring system without X-ray exposure. The manubrium of the sternum is a good location for measuring the baseline shift of a patient's body at all times. The real-time monitoring system may be useful for measuring the baseline shift of a patient's body independently of a gating system. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. Very-Long-Baseline Radio Interferometry: The Mark III System for Geodesy, Astrometry, and Aperture Synthesis.

    Science.gov (United States)

    Rogers, A E; Cappallo, R J; Hinteregger, H F; Levine, J I; Nesman, E F; Webber, J C; Whitney, A R; Clark, T A; Ma, C; Ryan, J; Corey, B E; Counselman, C C; Herring, T A; Shapiro, I I; Knight, C A; Shaffer, D B; Vandenberg, N R; Lacasse, R; Mauzy, R; Rayhrer, B; Schupler, B R; Pigg, J C

    1983-01-07

    The Mark III very-long-baseline interferometry (VLBI) system allows recording and later processing of up to 112 megabits per second from each radio telescope of an interferometer array. For astrometric and geodetic measurements, signals from two radio-frequency bands (2.2 to 2.3 and 8.2 to 8.6 gigahertz) are sampled and recorded simultaneously at all antenna sites. From these dual-band recordings the relative group delays of signals arriving at each pair of sites can be corrected for the contributions due to the ionosphere. For many radio sources for which the signals are sufficiently intense, these group delays can be determined with uncertainties under 50 picoseconds. Relative positions of widely separated antennas and celestial coordinates of radio sources have been determined from such measurements with 1 standard deviation uncertainties of about 5 centimeters and 3 milliseconds of arc, respectively. Sample results are given for the lengths of baselines between three antennas in the United States and three in Europe as well as for the arc lengths between the positions of six extragalactic radio sources. There is no significant evidence of change in any of these quantities. For mapping the brightness distribution of such compact radio sources, signals of a given polarization, or of pairs of orthogonal polarizations, can be recorded in up to 28 contiguous bands each nearly 2 megahertz wide. The ability to record large bandwidths and to link together many large radio telescopes allows detection and study of compact sources with flux densities under 1 millijansky.

  19. Passive heat removal system with injector-condenser

    Energy Technology Data Exchange (ETDEWEB)

    Soplenkov, K I [All-Russian Inst. of Nuclear Power Plant Operation, Electrogorsk Research and Engineering Centre of Nuclear Power Safety (Russian Federation)

    1996-12-01

    The system described in this paper is a passive system for decay heat removal from WWERs. It operates off the secondary side of the steam generators (SG). Steam is taken from the SG to operate a passive injector pump which causes secondary fluid to be pumped through a heat exchanger. Variants pass either water or steam from the SG through the heat exchanger. There is a passive initiation scheme. The programme for experimental and theoretical validation of the system is described. (author). 8 figs.

  20. Waste removal systems and recycling participation in residential environments

    DEFF Research Database (Denmark)

    Thøgersen, John

    2002-01-01

    Systems for the removal of waste are important although often overlooked elements of any residential environment. It is an old insight that when these systems are ineffective (and this is globally and historically the rule rather than the exception), human living conditions and often even human...... health are severely impaired (Pieters, 1989). More recently, resource waste and environmental hazards from waste have given rise to public and political concern as well, even when disposal systems are well managed. This concern has led to efforts to divert solid waste away from disposal and towards some...

  1. Northwest Boundary Containment/Treatment System Baseline Conditions, System Startup, and Operational Assessment. Volume 1.

    Science.gov (United States)

    1987-12-01

    combination pressure reducing check valve that is manually I controlled. A shutoff valve is installed on each well discharge line to iso - late the well from...system. This profile exhibits a relatively gentle, stable gradient between wells 27003 and 22051 which is due to the alignment of this portion of the...isoconcentration lines. As a result, the iso - 3 concentration maps for this period were constructed using isoconcentration maps for the later years as a

  2. BOA II: pipe-asbestos insulation removal system

    International Nuclear Information System (INIS)

    Schempf, H.; Mutschler; Boehmke, S.; Chemel, B.; Piepgras, C.

    1996-01-01

    BOA system is a mobile pipe-external robotic crawler used to remotely strip and bag asbestos-containing lagging and insulation materials from various diameter pipes in (primarily) industrial installations. Steam and process lines within the DOE weapons complex warrant the use of a remote device due to high labor costs and high level of radioactive contamination, making manual removal costly and inefficient. Currently targeted facilities for demonstration and remediation are Fernald in Ohio and Oak Ridge in Tennessee

  3. UAS Integration Into the NAS: An Examination of Baseline Compliance in the Current Airspace System

    Science.gov (United States)

    Fern, Lisa; Kenny, Caitlin A.; Shively, Robert J.; Johnson, Walter

    2012-01-01

    As a result of the FAA Modernization and Reform Act of 2012, Unmanned Aerial Systems (UAS) are expected to be integrated into the National Airspace System (NAS) by 2015. Several human factors challenges need to be addressed before UAS can safely and routinely fly in the NAS with manned aircraft. Perhaps the most significant challenge is for the UAS to be non-disruptive to the air traffic management system. Another human factors challenge is how to provide UAS pilots with intuitive traffic information in order to support situation awareness (SA) of their airspace environment as well as a see-and-avoid capability comparable to manned aircraft so that a UAS pilot could safely maneuver the aircraft to maintain separation and collision avoidance if necessary. A simulation experiment was conducted to examine baseline compliance of UAS operations in the current airspace system. Researchers also examined the effects of introducing a Cockpit Situation Display (CSD) into a UAS Ground Control Station (GCS) on UAS pilot performance, workload and situation awareness while flying in a positively controlled sector. Pilots were tasked with conducting a highway patrol police mission with a Medium Altitude Long Endurance (MALE) UAS in L.A. Center airspace with two mission objectives: 1) to reroute the UAS when issued new instructions from their commander, and 2) to communicate with Air Traffic Control (ATC) to negotiate flight plan changes and respond to vectoring and altitude change instructions. Objective aircraft separation data, workload ratings, SA data, and subjective ratings regarding UAS operations in the NAS were collected. Results indicate that UAS pilots were able to comply appropriately with ATC instructions. In addition, the introduction of the CSD improved pilot SA and reduced workload associated with UAS and ATC interactions.

  4. The personalized reminder information and social management system (PRISM) trial: rationale, methods and baseline characteristics.

    Science.gov (United States)

    Czaja, Sara J; Boot, Walter R; Charness, Neil; A Rogers, Wendy; Sharit, Joseph; Fisk, Arthur D; Lee, Chin Chin; Nair, Sankaran N

    2015-01-01

    Technology holds promise in terms of providing support to older adults. To date, there have been limited robust systematic efforts to evaluate the psychosocial benefits of technology for older people and identify factors that influence both the usability and uptake of technology systems. In response to these issues, we developed the Personal Reminder Information and Social Management System (PRISM), a software application designed for older adults to support social connectivity, memory, knowledge about topics, leisure activities and access to resources. This trail is evaluating the impact of access to the PRISM system on outcomes such as social isolation, social support and connectivity. This paper reports on the approach used to design the PRISM system, study design, methodology and baseline data for the trial. The trial is multi-site randomized field trial. PRISM is being compared to a Binder condition where participants received a binder that contained content similar to that found on PRISM. The sample includes 300 older adults, aged 65-98 years, who lived alone and at risk for being isolated. The primary outcome measures for the trial include indices of social isolation and support and well-being. Secondary outcomes measures include indices of computer proficiency, technology uptake and attitudes towards technology. Follow-up assessments occurred at 6 and 12 months post-randomization. The results of this study will yield important information about the potential value of technology for older adults. The study also demonstrates how a user-centered iterative design approach can be incorporated into the design and evaluation of an intervention protocol. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. High-efficiency SO2 removal in utility FGD systems

    International Nuclear Information System (INIS)

    Phillips, J.L.; Gray, S.; Dekraker, D.

    1995-01-01

    The U.S. Department of Energy (DOE) and the Electric Power Research Institute (EPRI) have contracted with Radian Corporation to conduct full-scale testing, process modeling, and economic evaluations of six existing utility flue gas desulfurization (FGD) systems. The project objective is to evaluate low capital cost upgrades for achieving up to 98% sulfur dioxide (SO 2 ) removal efficiency in a variety of FGD system types. The systems include dual-loop, packed absorbers at Tampa Electric Company's Big Bend Station; cocurrent, packed absorbers at Hoosier Energy's Merom Station; dual-loop absorbers with perforated-plate trays at Southwestern Electric Power Company's Pirkey Station; horizontal spray absorbers at PSI Energy's Gibson Station; venturi scrubbers at Duquesne Light's Elrama Station; and open stray absorbers at New york State Electric and Gas Corporations's (NYSEG's) Kintigh Station. All operate in an inhibited-oxidation mode except the system at Big Bend (forced oxidation), and all use limestone reagent except the Elrama system (Mg-lime). The program was conducted to demonstrate that upgrades such as performance additives and/or mechanical modifications can increase system SO 2 removal at low cost. The cost effectiveness of each upgrade has been evaluated on the basis of test results and/or process model predictions for upgraded performance and utility-specific operating and maintenance costs. Results from this upgraded performance and utility-specific operating and maintenance costs. Results from this program may lead some utilities to use SO 2 removal upgrades as an approach for compliance with phase 2 of Title IV of the Clean Air Act Amendments (CAAA) of 1990. This paper summarizes the results of testing, modeling, and economic evaluations that have been completed since July, 1994

  6. Tank Waste Remediation System retrieval and disposal mission technical baseline summary description

    International Nuclear Information System (INIS)

    McLaughlin, T.J.

    1998-01-01

    This document is prepared in order to support the US Department of Energy's evaluation of readiness-to-proceed for the Waste Retrieval and Disposal Mission at the Hanford Site. The Waste Retrieval and Disposal Mission is one of three primary missions under the Tank Waste Remediation System (TWRS) Project. The other two include programs to characterize tank waste and to provide for safe storage of the waste while it awaits treatment and disposal. The Waste Retrieval and Disposal Mission includes the programs necessary to support tank waste retrieval, wastefeed, delivery, storage and disposal of immobilized waste, and closure of tank farms. This mission will enable the tank farms to be closed and turned over for final remediation. The Technical Baseline is defined as the set of science and engineering, equipment, facilities, materials, qualified staff, and enabling documentation needed to start up and complete the mission objectives. The primary purposes of this document are (1) to identify the important technical information and factors that should be used by contributors to the mission and (2) to serve as a basis for configuration management of the technical information and factors

  7. Containment hydrogen removal system for a nuclear power plant

    International Nuclear Information System (INIS)

    Callaghan, V.M.; Flynn, E.P.; Pokora, B.M.

    1984-01-01

    A hydrogen removal system (10) separates hydrogen from the containment atmosphere of a nuclear power plant using a hydrogen permeable membrane separator (30). Water vapor is removed by condenser (14) from a gas stream withdrawn from the containment atmosphere. The gas stream is then compressed by compressor (24) and cooled (28,34) to the operating temperature of the hydrogen permeable membrane separator (30). The separator (30) separates the gas stream into a first stream, rich in hydrogen permeate, and a second stream that is hydrogen depleted. The separated hydrogen is passed through a charcoal adsorber (48) to adsorb radioactive particles that have passed through the hydrogen permeable membrane (44). The hydrogen is then flared in gas burner (52) with atmospheric air and the combustion products vented to the plant vent. The hydrogen depleted stream is returned to containment through a regenerative heat exchanger (28) and expander (60). Energy is extracted from the expander (60) to drive the compressor (24) thereby reducing the energy input necessary to drive the compressor (24) and thus reducing the hydrogen removal system (10) power requirements

  8. Satellite refrigerator compressors with the oil and moisture removal systems

    International Nuclear Information System (INIS)

    Satti, J.A.

    1983-08-01

    There are twenty-eight compressors installed around the Main Accelerator Ring in seven locations. Drawing 9140-ME-129720 shows the piping and the components schematic for four Mycom compressor skids per building with each having an independent oil and moisture removal system. The Mycom skids each consist of an oil injected screw compressor of 750 SCFM capacity with a 350 hp motor, oil pump, oil cooler, and oil separator. Helium gas returning from the heat exchanger train is compressed from 1 atm to 20 atm in the compressor. The compressed gas is then passed through the three coalescer de-mister where oil mist is separated from the helium gas. The helium gas then flows through the charcoal adsorber and molecular sieve where any residual oil vapor and water vapor are removed. The final stage of purification is the final filter which removes any remaining particulates from the compressed helium gas. The end product of this system is compressed and purified helium gas ready to be cooled down to cryogenic temperatures

  9. ENSURING SANITARY RELIABILITY OF TERRITORIES WHEN USING REMOVABLE SEWERAGE SYSTEM

    Directory of Open Access Journals (Sweden)

    Nikitina Irina Nikolaevna

    2015-12-01

    Full Text Available It was found out that in most cases the system of removable water disposal is arranged with violations, i.e. cesspools that collect runoffs are either not designed at all — waste water merge into an open trench (ditch, and then water is filtered into the ground, or are designed against the rules (instead of a cesspool the user presupposes a simple hole dug in the ground. The authors witnessed the cases of ingress of wastewater into open waters, near which holiday villages are situated. This fact raises the question on the necessity of solving these problems which will prevent pollution of soil and surface waters, as well as the surrounding areas by sewages to prevent the development of infections and to prevent environmental disaster on a local scale. If you have a small rate of water flow in a summer cottage, it is feasible to design a sump for removal of faecal discharge (human physiological discharge, which are the most dangerous. It is advisable to install in the ground sealed (cumulative capacity, and build headroom on the top in the form of a toilet cabin (detached structure. This will allow completely getting rid of contamination with sewage effluents. The volume of the tank must be calculated individually depending on the water consumption on the site. Periodically it is needed to call out a cesspoolage truck after filling the reservoir, which would be then emptied of faecal material. In the last 20 years in our country a promising trend in removable sanitation began to develop — bio toilets. They became popular in country houses, as well as for persons with disabilities A composting toilet is a portable container, which is very compact and can be installed in any location of a country house. A more costly option, but an environmentally sound and convenient one to use is the construction of local water disposal systems with the use of not only mechanical, but also biological treatment. The choice of a particular scheme of

  10. BOA: Asbestos pipe insulation removal robot system. Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    Schempf, H.; Bares, J.E.

    1995-02-01

    The project described in this report targets the development of a mechanized system for safe, cost-efficient and automated abatement of asbestos containing materials used as pipe insulation. Based on several key design criteria and site visits, a proof-of-concept prototype robot system, dubbed BOA, was designed and built, which automatically strips the lagging and insulation from the pipes, and encapsulates them under complete vacuum operation. The system can operate on straight runs of piping in horizontal or vertical orientations. Currently we are limited to four-inch diameter piping without obstacles as well as a somewhat laborious emplacement and removal procedure -- restrictions to be alleviated through continued development. BOA removed asbestos at a rate of 4-5 ft./h compared to 3 ft./h for manual removal of asbestos with a 3-person crew. The containment and vacuum system on BOA was able to achieve the regulatory requirement for airborne fiber emissions of 0.01 fibers/ccm/ 8-hr. shift. This program consists of two phases. The first phase was completed and a demonstration was given to a review panel, consisting of DOE headquarters and site representatives as well as commercial abatement industry representatives. Based on the technical and programmatic recommendations drafted, presented and discussed during the review meeting, a new plan for the Phase II effort of this project was developed. Phase 11 will consist of a 26-month effort, with an up-front 4-month site-, market-, cost/benefit and regulatory study before the next BOA robot (14 months) is built, and then deployed and demonstrated (3 months) at a DOE site (such as Fernald or Oak Ridge) by the beginning of FY`97.

  11. BOA: Pipe-asbestos insulation removal robot system

    Energy Technology Data Exchange (ETDEWEB)

    Schempf, H.; Bares, J.; Schnorr, W. [Carnegie Mellon Univ., Pittsburgh, PA (United States)

    1995-10-01

    The BOA system is a mobile pipe-external robotic crawler used to remotely strip and bag asbestos-containing lagging and insulation materials (ACLIM) from various diameter pipes in (primarily) industrial installations. Steam and process lines within the DOE weapons complex warrant the use of a remote device due to the high labor costs and high level of radioactive contamination, making manual removal extremely costly and highly inefficient. Currently targeted facilities for demonstration and remediation are Fernald in Ohio and Oak Ridge in Tennessee.

  12. BOA: Pipe-asbestos insulation removal robot system

    International Nuclear Information System (INIS)

    Schempf, H.; Bares, J.; Schnorr, W.

    1995-01-01

    The BOA system is a mobile pipe-external robotic crawler used to remotely strip and bag asbestos-containing lagging and insulation materials (ACLIM) from various diameter pipes in (primarily) industrial installations. Steam and process lines within the DOE weapons complex warrant the use of a remote device due to the high labor costs and high level of radioactive contamination, making manual removal extremely costly and highly inefficient. Currently targeted facilities for demonstration and remediation are Fernald in Ohio and Oak Ridge in Tennessee

  13. Efficient TEA CO2 laser based coating removal system

    CSIR Research Space (South Africa)

    Prinsloo, FJ

    2007-04-01

    Full Text Available stream_source_info Prinsloo_2007.pdf.txt stream_content_type text/plain stream_size 11617 Content-Encoding UTF-8 stream_name Prinsloo_2007.pdf.txt Content-Type text/plain; charset=UTF-8 Efficient TEA CO2 laser based... by keeping energy density below the damage threshold. The advantage of a pulsed TEA CO2 laser system is that a laser frequency and temporal profile can be chosen to maximize paint removal and concurrently minimize substrate damage. To achieve...

  14. Simultaneous biological nutrient removal: evaluation of autotrophic denitrification, heterotrophic nitrification, and biological phosphorus removal in full-scale systems.

    Science.gov (United States)

    Littleton, Helen X; Daigger, Glen T; Strom, Peter F; Cowan, Robert A

    2003-01-01

    Simultaneous biological nutrient removal (SBNR) is the biological removal of nitrogen and phosphorus in excess of that required for biomass synthesis in a biological wastewater treatment system without defined anaerobic or anoxic zones. Evidence is growing that significant SBNR can occur in many systems, including the aerobic zone of systems already configured for biological nutrient removal. Although SBNR systems offer several potential advantages, they cannot be fully realized until the mechanisms responsible for SBNR are better understood. Consequently, a research program was initiated with the basic hypothesis that three mechanisms might be responsible for SBNR: the reactor macroenvironment, the floc microenvironment, and novel microorganisms. Previously, the nutrient removal capabilities of seven full-scale, staged, closed-loop bioreactors known as Orbal oxidation ditches were evaluated. Chemical analysis and microbiological observations suggested that SBNR occurred in these systems. Three of these plants were further examined in this research to evaluate the importance of novel microorganisms, especially for nitrogen removal. A screening tool was developed to determine the relative significance of the activities of microorganisms capable of autotrophic denitrification and heterotrophic nitrification-aerobic denitrification in biological nutrient removal systems. The results indicated that novel microorganisms were not substantial contributors to SBNR in the plants studied. Phosphorus metabolism (anaerobic release, aerobic uptake) was also tested in one of the plants. Activity within the mixed liquor that was consistent with current theories for phosphorus-accumulating organisms (PAOs) was observed. Along with other observations, this suggests the presence of PAOs in the facilities studied.

  15. Understanding Kendal aquifer system: a baseline analysis for sustainable water management proposal

    Science.gov (United States)

    Lukman, A.; Aryanto, M. D.; Pramudito, A.; Andhika, A.; Irawan, D. E.

    2017-07-01

    North coast of Java has been grown as the center of economic activities and major connectivity hub for Sumatra and Bali. Sustainable water management must support such role. One of the basis is to understand the baseline of groundwater occurrences and potential. However the complex alluvium aquiver system has not been well-understood. A geoelectric measurements were performed to determine which rock layer has a good potential as groundwater aquifers in the northern coast of Kaliwungu Regency, Kendal District, Central Java province. Total of 10 vertical electrical sounding (VES) points has been performed, using a Schlumberger configuration with the current electrode spacing (AB/2) varies between 200 - 300 m and the potential difference electrode spacing (MN/2) varies between 0.5 to 20 m with depths target ranging between 150 - 200 m. Geoelectrical data processing is done using Ip2win software which generates resistivity value, thickness and depth of subsurface rock layers. Based on the correlation between resistivity value with regional geology, hydrogeology and local well data, we identify three aquifer layers. The first layer is silty clay with resistivity values vary between 0 - 10 ohm.m, then the second layer is tuffaceous claystone with resistivity value between 10 - 60 ohm.m. Both layers serve as impermeable layer. The third layer is sandy tuff with resistivity value between 60 - 100 ohm.m which serves as a confined aquifer layer located at 70 - 100 m below surface. Its thickness is vary between 70 to 110 m. The aquifer layer is a mixing of volcanic and alluvium sediment, which is a member of Damar Formation. The stratification of the aquifer system may change in short distance and depth. This natural setting prevent us to make a long continuous correlation between layers. Aquifer discharge is estimated between 5 - 71 L/s with the potential deep well locations lies in the west and southeast part of the study area. These hydrogeological settings should be used

  16. Geodesy by radio interferometry - Determinations of baseline vector, earth rotation, and solid earth tide parameters with the Mark I very long baseline radio interferometery system

    Science.gov (United States)

    Ryan, J. W.; Clark, T. A.; Coates, R. J.; Ma, C.; Wildes, W. T.

    1986-01-01

    Thirty-seven very long baseline radio interferometry experiments performed between 1972 and 1978 are analyzed and estimates of baseline vectors between six sites, five in the continental United States and one in Europe are derived. No evidence of significant changes in baseline length is found. For example, with a statistical level of confidence of approximately 85 percent, upper bounds on such changes within the United States ranged from a low of 10 mm/yr for the 850 km baseline between Westford, Massachusetts, and Green Bank, West Virginia, to a high of 90 mm/yr for the nearly 4000 km baseline between Westford and Goldstone, California. Estimates for universal time and for the x component of the position of the earth's pole are obtained. For the last 15 experiments, the only ones employing wideband receivers, the root-mean-square differences between the derived values and the corresponding ones published by the Bureau International de l'Heure are 0.0012 s and 0.018 arc sec respectively. The average value obtained for the radial Love number for the solid earth is 0.62 + or - 0.02 (estimated standard error).

  17. Advanced fiber information systems seed coat neps baseline response from diverse mediums

    Science.gov (United States)

    An extensive literature search has revealed that no papers have been published regarding selectivity calculation of the AFIS seed coat neps (SCN) determination over interfering material in cotton. A prerequisite to selectivity measurements is to identify suitable fiber medium(s) that give baseline ...

  18. Process and system for removing impurities from a gas

    Science.gov (United States)

    Henningsen, Gunnar; Knowlton, Teddy Merrill; Findlay, John George; Schlather, Jerry Neal; Turk, Brian S

    2014-04-15

    A fluidized reactor system for removing impurities from a gas and an associated process are provided. The system includes a fluidized absorber for contacting a feed gas with a sorbent stream to reduce the impurity content of the feed gas; a fluidized solids regenerator for contacting an impurity loaded sorbent stream with a regeneration gas to reduce the impurity content of the sorbent stream; a first non-mechanical gas seal forming solids transfer device adapted to receive an impurity loaded sorbent stream from the absorber and transport the impurity loaded sorbent stream to the regenerator at a controllable flow rate in response to an aeration gas; and a second non-mechanical gas seal forming solids transfer device adapted to receive a sorbent stream of reduced impurity content from the regenerator and transfer the sorbent stream of reduced impurity content to the absorber without changing the flow rate of the sorbent stream.

  19. System Study: Residual Heat Removal 1998-2014

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, John Alton [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-12-01

    This report presents an unreliability evaluation of the residual heat removal (RHR) system in two modes of operation (low-pressure injection in response to a large loss-of-coolant accident and post-trip shutdown-cooling) at 104 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing trends were identified in the RHR results. A highly statistically significant decreasing trend was observed for the RHR injection mode start-only unreliability. Statistically significant decreasing trends were observed for RHR shutdown cooling mode start-only unreliability and RHR shutdown cooling model 24-hour unreliability.

  20. Passive safety systems for decay heat removal of MRX

    Energy Technology Data Exchange (ETDEWEB)

    Ochiai, M; Iida, H; Hoshi, T [Japan Atomic Energy Research Inst., Ibaraki (Japan). Nuclear Ship System Lab.

    1996-12-01

    The MRX (marine Reactor X) is an advanced marine reactor, its design has been studied in Japan Atomic Energy Research Institute. It is characterized by four features, integral type PWR, in-vessel type control rod drive mechanisms, water-filled containment vessel and passive decay heat removal system. A water-filled containment vessel is of great advantage since it ensures compactness of a reactor plant by realizing compact radiation shielding. The containment vessel also yields passive safety of MRX in the event of a LOCA by passively maintaining core flooding without any emergency water injection. Natural circulation of water in the vessels (reactor and containment vessels) is one of key factors of passive decay heat removal systems of MRX, since decay heat is transferred from fuel rods to atmosphere by natural circulation of the primary water, water in the containment vessel and thermal medium in heat pipe system for the containment vessel water cooling in case of long terms cooling after a LOCA as well as after reactor scram. Thus, the ideal of water-filled containment vessel is considered to be very profitable and significant in safety and economical point of view. This idea is, however, not so familiar for a conventional nuclear system, so experimental and analytical efforts are carried out for evaluation of hydrothermal behaviours in the reactor pressure vessel and in the containment vessel in the event of a LOCA. The results show the effectiveness of the new design concept. Additional work will also be conducted to investigate the practical maintenance of instruments in the containment vessel. (author). 4 refs, 9 figs, 2 tabs.

  1. Asbestos removal and disposal information system: a user's guide

    International Nuclear Information System (INIS)

    Knight, P.S.; Eisenhower, B.M.

    1982-10-01

    Program ASBS01, written for the staff of the Department of Environmental Management (DEM) at Oak Ridge National Laboratory (ORNL), is an on-line management information system that provides file maintenance and information retrievability for demolition and/or renovation operations involving friable (capable of becoming an airborne health hazard) asbestos material at the Laboratory. System 1022 is the data base management system used. The screen processor SCOPE provides the DEM staff with system prompts for ease of use and data integrity. Data for the system comes from two UCN forms: (1) Notice of Intention to Demolish or Renovate Friable Asbestos Material (UCN-13385) and (2) Request for the Disposal of Asbestos or Material Containing Asbestos (UCN-13386). Examples of the forms are in Appendix A. Data is entered into the system as requests are submitted to DEM. Total amounts of friable asbestos removed in demolition and/or renovation operations can be generated by the program upon user request. These totals are submitted in a quarterly report to the Environmental Protection Branch of the US Department of Energy (DOE) on a continuing basis (see Appendix B). This report describes the operation of the computer program ASBS01 from data entry to generation of totals. Each data attribute of the master file ASBSTO.DMS is described in detail, and a sample session is given for user reference

  2. Usefulness of a clinical scoring system to anticipate difficulty of Norplant removal.

    Science.gov (United States)

    Blumenthal, P D; Remsburg, R E; Glew, G; McGrath, J A; Gaffikin, L

    1995-12-01

    Removal of contraceptive implants (e.g. Norplant) is an issue affecting its worldwide acceptability. Reports of difficult, painful removals have resulted in lawsuits and reduced demand. To improve quality of care, we developed a scoring system to anticipate difficult removals. We report on the usefulness of such a system and present client perspectives about the removal experience. A 9-point scoring system based on the visibility, arrangement, and position (VAP) of Norplant capsules was used to assess the anticipated difficulty of removal in 53 consecutive patients. The VAP score was then correlated with removal time and related parameters. Mean removal time was 14.74 min (range 4.75-47). In 20% of patients, the VAP score indicated a potentially difficult removal and the VAP score correlated significantly with removal time (r = 0.3, p = 0.05). Patients expected removal to be moderately difficult (mean visual analog score 4.7 out of a possible 10), but after removal they rated the actual removal experience as relatively easy (mean score 2.6/10). Before the removal, only 48% of patients said they would recommend Norplant to a friend but after removal, 70% said they would do so. A scoring system such as the VAP score can help identify potentially difficult removals so that an experienced remover can be present at the time of removal or an appropriate referral made. However, the VAP score cannot predict variables such as the density of the subcutaneous fibrous tissue "envelope". Although patient anxiety concerning removal may be high, the presence of a competent remover and an easy removal experience reduces this anxiety and encourages patients to be more positive about this method. The value of having properly trained, competent personnel available to perform removals cannot be over-emphasized.

  3. Relationship between removable prosthesis and some systemics disorders

    Directory of Open Access Journals (Sweden)

    Pierre Le Bars

    2015-01-01

    Full Text Available This article reviews the dental literature concerning the potential impact of the removable prosthesis (RP on the health status of patients with certain systemic diseases. Literature was surveyed using Medline/PubMed database resources, as well as a manual search, up to 2015 to identify appropriate articles that addressed the aim of this review. The research used keywords about associations between RP and six pathologies: Human immunodeficiency virus infection, diabetes mellitus, pulmonary diseases, gastric-Helicobacter pylori, cancer, and cardiovascular diseases. Analysis of literature showed that in patients with dentures having one or more of the six general conditions listed, Candida albicans organism is more frequently found in the oral flora compared to healthy denture wearer. Although causality has not been established and pending further research on this topic, the hygienic practices necessary to minimize the risk of numerous pathologies should be strengthened in the case of these patients, all the more in the presence of physical or psychological disability. The relationship between the general diseases and increasing of oral candidiasis denture patients is not explained. Therefore, attention to oral hygiene and professional care for removing C. albicans may be beneficial in these medically compromised patients.

  4. Relationship between removable prosthesis and some systemics disorders.

    Science.gov (United States)

    Le Bars, Pierre; Kouadio, Alain Ayepa; N'goran, Justin Koffi; Badran, Zahi; Soueidan, Assem

    2015-01-01

    This article reviews the dental literature concerning the potential impact of the removable prosthesis (RP) on the health status of patients with certain systemic diseases. Literature was surveyed using Medline/PubMed database resources, as well as a manual search, up to 2015 to identify appropriate articles that addressed the aim of this review. The research used keywords about associations between RP and six pathologies: Human immunodeficiency virus infection, diabetes mellitus, pulmonary diseases, gastric-Helicobacter pylori, cancer, and cardiovascular diseases. Analysis of literature showed that in patients with dentures having one or more of the six general conditions listed, Candida albicans organism is more frequently found in the oral flora compared to healthy denture wearer. Although causality has not been established and pending further research on this topic, the hygienic practices necessary to minimize the risk of numerous pathologies should be strengthened in the case of these patients, all the more in the presence of physical or psychological disability. The relationship between the general diseases and increasing of oral candidiasis denture patients is not explained. Therefore, attention to oral hygiene and professional care for removing C. albicans may be beneficial in these medically compromised patients.

  5. Alternatives Generation Analysis Long Length Contaminated Equipment Removal System Storage

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    Major pieces of Characterization sampling equipment are currently stored outdoors. This includes the Long Length Contaminated Equipment receiver trailer and transportation trailer. A decision is required to determine the preferred alternative for facilities to store and maintain this equipment. The Long Length Contaminated Equipment Removal System (LLCERS) consists of many tools, mechanisms, and controllers currently stored in various locations. Much of this equipment should be protected from the elements while being stored. Some of the LLCERS equipment should be protected with some kind of roof cover. This decision analysis is to determine the best alternative for weather protection for the large equipment requiring a cover. Additional details are included in Sections 2.0 and 5.0. Key assumptions used in this analysis are detailed in Section 3.2

  6. Removal of triazine herbicides from freshwater systems using photosynthetic microorganisms

    International Nuclear Information System (INIS)

    Gonzalez-Barreiro, O.; Rioboo, C.; Herrero, C.; Cid, A.

    2006-01-01

    The uptake of the triazine herbicides, atrazine and terbutryn, was determined for two freshwater photosynthetic microorganisms, the green microalga Chlorella vulgaris and the cyanobacterium Synechococcus elongatus. An extremely rapid uptake of both pesticides was recorded, although uptake rate was lower for the cyanobacterium, mainly for atrazine. Other parameters related to the herbicide bioconcentration capacity of these microorganisms were also studied. Growth rate, biomass, and cell viability in cultures containing herbicide were clearly affected by herbicide uptake. Herbicide toxicity and microalgae sensitivity were used to determine the effectiveness of the bioconcentration process and the stability of herbicide removal. C. vulgaris showed higher bioconcentration capability for these two triazine herbicides than S. elongatus, especially with regard to terbutryn. This study supports the usefulness of such microorganisms, as a bioremediation technique in freshwater systems polluted with triazine herbicides

  7. Removal of triazine herbicides from freshwater systems using photosynthetic microorganisms

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Barreiro, O. [Laboratorio de Microbiologia, Facultad de Ciencias, Universidad de A Coruna, Campus da Zapateira s/n. 15071 A Coruna (Spain); Rioboo, C. [Laboratorio de Microbiologia, Facultad de Ciencias, Universidad de A Coruna, Campus da Zapateira s/n. 15071 A Coruna (Spain); Herrero, C. [Laboratorio de Microbiologia, Facultad de Ciencias, Universidad de A Coruna, Campus da Zapateira s/n. 15071 A Coruna (Spain); Cid, A. [Laboratorio de Microbiologia, Facultad de Ciencias, Universidad de A Coruna, Campus da Zapateira s/n. 15071 A Coruna (Spain)]. E-mail: cid@udc.es

    2006-11-15

    The uptake of the triazine herbicides, atrazine and terbutryn, was determined for two freshwater photosynthetic microorganisms, the green microalga Chlorella vulgaris and the cyanobacterium Synechococcus elongatus. An extremely rapid uptake of both pesticides was recorded, although uptake rate was lower for the cyanobacterium, mainly for atrazine. Other parameters related to the herbicide bioconcentration capacity of these microorganisms were also studied. Growth rate, biomass, and cell viability in cultures containing herbicide were clearly affected by herbicide uptake. Herbicide toxicity and microalgae sensitivity were used to determine the effectiveness of the bioconcentration process and the stability of herbicide removal. C. vulgaris showed higher bioconcentration capability for these two triazine herbicides than S. elongatus, especially with regard to terbutryn. This study supports the usefulness of such microorganisms, as a bioremediation technique in freshwater systems polluted with triazine herbicides.

  8. Analysis of a space debris laser removal system

    Science.gov (United States)

    Gjesvold, Evan; Straub, Jeremy

    2017-05-01

    As long as man ventures into space, he will leave behind debris, and as long as he ventures into space, this debris will pose a threat to him and his projects. Space debris must be located and decommissioned. Lasers may prove to be the ideal method, as they can operate at a distance from the debris, have a theoretically infinite supply of energy from the sun, and are a seemingly readily available technology. This paper explores the requirements and reasoning for such a laser debris removal method. A case is made for the negligibility of eliminating rotational velocity from certain systems, while a design schematic is also presented for the implementation of a cube satellite proof of concept.

  9. Baseline identification in stable -isotope studies of temperate lotic systems and implications for calculated trophic positions

    DEFF Research Database (Denmark)

    Kristensen, Peter Brinkmann; Riis, Tenna; Dylmer, Hans Erik

    2016-01-01

    of two common fish species (three-spined stickleback, Gasterosteus aculeatus, and brown trout Salmo trutta) differed markedly depending on the baseline chosen. The estimated trophic position was lowest when based on Baetidae and highest when using Simuliidae. The trophic position of Gasterosteus...... aculeatus was independent of land use (proxy used=%nature) when based on Gammarus pulex and Simuliidae, and the trophic position of Salmo trutta was independent of land use when based on Simuliidae only. The trophic position estimates based on Baetidae and mean primary consumers correlated with %nature...

  10. Baseline rationing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Moreno-Ternero, Juan D.; Østerdal, Lars Peter Raahave

    The standard problem of adjudicating conflicting claims describes a situation in which a given amount of a divisible good has to be allocated among agents who hold claims against it exceeding the available amount. This paper considers more general rationing problems in which, in addition to claims...... to international protocols for the reduction of greenhouse emissions, or water distribution in drought periods. We define a family of allocation methods for such general rationing problems - called baseline rationing rules - and provide an axiomatic characterization for it. Any baseline rationing rule within...... the family is associated with a standard rule and we show that if the latter obeys some properties reflecting principles of impartiality, priority and solidarity, the former obeys them too....

  11. Performance of ALMR passive decay heat removal system

    International Nuclear Information System (INIS)

    Boardman, C.E.; Hunsbedt, A.

    1991-01-01

    The Advanced Liquid Metal Reactor (ALMR) concept has a totally passive safety-grade decay heat removal system referred to as the Reactor Vessel Auxiliary Cooling System (RVACS) that rejects heat from the small (471 MWt) modular reactor to the environmental air by natural convection heat transfer. The system has no active components, requires no operator action to initiate, and is inherently reliable. The RVACS can perform its function under off-normal or degraded operating conditions without significant loss in performance. Several such events are described and the RVACS thermal performance for each is given and compared to the normal operation performance. The basic RVACS performance as well as the performance during several off-normal events have been updated to reflect design changes for recycled fuel with minor actinides for end of equilibrium cycle conditions. The performance results for several other off-normal events involving various degrees of RVACS air flow passage blockages are presented. The results demonstrated that the RVACS is unusually tolerant to a wide range of postulated faults. (author)

  12. Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems.

    Science.gov (United States)

    Macintosh, David L; Myatt, Theodore A; Ludwig, Jerry F; Baker, Brian J; Suh, Helen H; Spengler, John D

    2008-11-01

    A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-microm particles ranged from 1.5 hr(-1) during operation of an in-duct, 5-in. pleated media filter to 7.2 hr(-1) for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr(-1) when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 microm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr(-1) under baseline conditions, 0.5 hr(-1) during operation of three portable ionic air cleaners, 1 hr(-1) for an in-duct 1-in. media filter, 2.4 hr(-1) for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr(-1) for an in-duct 5-in. media filter, 4.7 hr(-1) during operation of five portable HEPA filters, 6.1 hr(-1) for a conventional in-duct electronic air cleaner, and 7.5 hr(-1) for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates.

  13. Shippingport Station Decommissioning Project: Removal of piping and equipment and removal of primary system components

    International Nuclear Information System (INIS)

    1989-01-01

    This report is a technical synopsis of the removal of contaminated and non-contaminated piping and equipment from the Shippingport Station Decommissioning Project (SSDP). The information is provided as a part of the Technology Transfer Program to document dismantling activities in support of reactor decommissioning. 5 refs., 29 figs., 4 tabs

  14. ROGER a potential orbital space debris removal system

    Science.gov (United States)

    Starke, Juergen; Bischof, Bernd; Foth, W.-O.; -J., J.; Günther

    The previous activities in the field of On Orbit Servicing studied in the 1990's included in partic-ular the capability of vehicles in GEO to capture and support satellites (mainly communication satellites) to enable repair and continuation of operations, and finally the controlled transfer the target into a permanent graveyard orbit. The specific capture tools for these applications were mostly based on robotic systems to capture and fix the target under specific dynamic constraints (e.g. slowly tumbling target) without damage, and to allow the stabilization, re-orientation and potential repair of the target and subsequent release or transport to the final disposal orbit. Due to the drastically increasing number of debris particularly in the Low Earth Orbits (SSO) the active debris removal is now necessary to counteract to the predicted debris production cascade (Kessler Syndrome), which means the pollution of the total sphere in low earth orbit and not only the SSO area. In most of the debris congresses it was recommended to start removal with the still integrated systems as soon as possible. In the case of large debris objects, the soft capture system can be replaced by a simpler and robust system able to operate from a safe distance to the target and flexible enough to capture and hold different types of targets such as deactivated and/or defective satellites, upper stages and big fragments. These nominally non -cooperative targets might be partially destroyed by the capture process, but the production of additional debris shall be avoided. A major argument for the commercial applications is a multi-target mission potential, which is possible at GEO because the transfer propellant requirement to the disposal orbit and the return to the orbit of the next potential target is relative low (orbits with similar inclination and altitude). The proposed ROGER system is designed as a spacecraft with rendezvous capabilities including inspection in the vicinity of the

  15. Multi-sensors multi-baseline mapping system for mobile robot using stereovision camera and laser-range device

    Directory of Open Access Journals (Sweden)

    Mohammed Faisal

    2016-06-01

    Full Text Available Countless applications today are using mobile robots, including autonomous navigation, security patrolling, housework, search-and-rescue operations, material handling, manufacturing, and automated transportation systems. Regardless of the application, a mobile robot must use a robust autonomous navigation system. Autonomous navigation remains one of the primary challenges in the mobile-robot industry; many control algorithms and techniques have been recently developed that aim to overcome this challenge. Among autonomous navigation methods, vision-based systems have been growing in recent years due to rapid gains in computational power and the reliability of visual sensors. The primary focus of research into vision-based navigation is to allow a mobile robot to navigate in an unstructured environment without collision. In recent years, several researchers have looked at methods for setting up autonomous mobile robots for navigational tasks. Among these methods, stereovision-based navigation is a promising approach for reliable and efficient navigation. In this article, we create and develop a novel mapping system for a robust autonomous navigation system. The main contribution of this article is the fuse of the multi-baseline stereovision (narrow and wide baselines and laser-range reading data to enhance the accuracy of the point cloud, to reduce the ambiguity of correspondence matching, and to extend the field of view of the proposed mapping system to 180°. Another contribution is the pruning the region of interest of the three-dimensional point clouds to reduce the computational burden involved in the stereo process. Therefore, we called the proposed system multi-sensors multi-baseline mapping system. The experimental results illustrate the robustness and accuracy of the proposed system.

  16. Iodine removal in containment filtered venting system during nuclear accident

    International Nuclear Information System (INIS)

    Bera, Subrata; Deo, Anuj Kumar; Nagrale, D.B.; Paul, U.K.; Prasad, M.; Gaikwad, A.J.

    2015-01-01

    Post Fukushima nuclear accident, containment filtered venting system is being introduced in Indian nuclear power plant to strengthen the defense in depth safety barrier by depressurizing the containment building along with minimization of radioactivity release to environment during a severe accident. Radioactive iodine is one of the major contributors to radiation dose during early release phase of a severe accident. Physical and Chemical form of iodine and iodine bearing compounds includes particulates, elemental and organic. In the most efficient design of CFVS, wet scrubbing mechanism has been employed through use of venture scrubber. The Iodine removal process in wet scrubber involves two processes: chemical reaction in highly alkaline aqueous solution and impingement of particulates with water droplets produced in the venturi nozzle. In this paper, venturi has been modeled using the Calvert model. The variation of efficiency has been estimated for the different particle sizes. The impact of the shape parameter of log-normal distribution on the amount of scrubbed iodine has also been assessed. Release phase wise the scrubbed amount of iodine in the venturi based CFVS system has been estimated for a typical BWR. (author)

  17. Removal of organic micropollutants in an artificial recharge system

    Science.gov (United States)

    Valhondo, C.; Nödler, K.; Köck-Schulmeyer, M.; Hernandez, M.; Licha, T.; Ayora, C.; Carrera, J.

    2012-04-01

    Emerging contaminants including pharmaceutically active compounds (PhACs), personal care products (PCPs) and pesticides are increasingly being identified in the environment. Emerging pollutants and their transformation products show low concentration in the environment (ng/L), but the effects of the mixtures and lifelong exposure to humans are currently unknown. Many of these contaminants are removed under aerobic conditions in water treatment plants. However, several pharmaceuticals and metabolites present in wastewater are not eliminated by conventional treatment processes. Several lab studies, however, show that the behaviour of many of these micropollutants is affected by the dominant redox conditions. However, data from field experiments are limited and sometimes contradictory. Artificial recharge is a widespread technology to increase the groundwater resources. In this study we propose a design to enhance the natural remediation potential of the aquifer with the installation of a reactive layer at the bottom of the infiltration pond. This layer is a mixture of compost, aquifer material, clay and iron oxide. This layer is intended to provide an extra amount of DOC to the recharge water and to promote biodegradation by means of the development of different redox zones along the travel path through the unsaturated zone and within the aquifer. Moreover, compost, clay and iron oxide of the layer are assumed to increase sorption surfaces for neutral, cationic and anionic compounds, respectively. The infiltration system is sited in Sant Vicenç dels Horts (Barcelona, Spain). It consists of a decantation pond, receiving raw water from the Llobregat River (highly affected from treatment plant effluents), and an infiltration pond (5600 m2). The infiltration rate is around 1 m3/m2/day. The system is equipped with a network of piezometers, suction cups and tensiometers. Infiltration periods have been performed before and after the installation of the reactive layer

  18. Predictive value of isolated DLCO reduction in systemic sclerosis patients without cardio-pulmonary involvement at baseline

    Directory of Open Access Journals (Sweden)

    M. Colaci

    2016-05-01

    Full Text Available Impaired diffusing capacity of the lung for carbon monoxide (DLCO was frequently observed in systemic sclerosis (SSc patients, generally related to the presence of interstitial lung disease (ILD and/or pulmonary arterial hypertension (PAH. However, in clinical practice abnormally low DLCO values may be found also in the absence of these SSc complications. The objective was to investigate the prospective clinical relevance of isolated DLCO reduction at baseline in SSc patients. Ninety-seven SSc female patients (age at the diagnosis: 51.3±14.5 years; disease duration: 10.4±6.6 years; limited/diffuse skin subsets: 92/5, without any clinical, radiological (high resolution computed tomography, and echocardiographic manifestations of ILD or PAH at baseline, nor other lung or heart diseases able to affect DLCO, were recruited at our Rheumatology Centre. Patients with DLCO <55% (15 patients; group A were compared with those with normal DLCO (82 patients; group B, at baseline and at the end of follow-up. At baseline, patients of group A showed significantly higher percentage of anticentromere autoantibodies compared to group B (13/15, 86.6% vs 48/82, 58.5%; p=0.044. More interestingly, at the end of long-lasting clinical follow-up (11.6±6.7 years, pre-capillary PAH (right heart catheterization solely developed in some patients of group A (3/15, 20% vs 0/82; p=0.003. In SSc patients, the presence at baseline of isolated, marked DLCO reduction (<55% of predicted and serum anticentromere autoantibodies might characterize a peculiar SSc subset that may precede the development of PAH. Therefore, careful clinical follow-up of patients with isolated moderate-severe DLCO reduction should be mandatory.

  19. Costs of Arsenic Removal Technologies for Small Water Systems: U.S. EPA Arsenic Removal Technology Demonstration Program

    Science.gov (United States)

    As part of the Arsenic Rule Implementation Research Program, between July 2003 and July 2011, the U.S. environmental Protection Agency (EPA) conducted 50 full-scale demonstration projects on treatment systems removing arsenic from drinking water in 26 states throughout the U.S. ...

  20. After heat removing system of a nuclear reactor

    International Nuclear Information System (INIS)

    Hayashi, Takao; Yamada, Masao; Ohashi, Kazutaka.

    1994-01-01

    In a variable conductance heat pipe of an after heat removing system, an evaporation portion and a condensator are connected by a steam diffusing path for an operation fluid and a liquid condensate recycling path. Further, incondensible gases are sealed at the inside together with the operation fluid, and a gas reservoir for the incondensible gases is disposed at the downstream of a condensation portion. If heat input is applied to the evaporation portion of the heat pipe, the incondensible gases are separated to form a boundary between both of them. When the amount of heat applied is small, the incondensible gases partially seal the condensation portion to form a local condensation insensitive portion, so that a heat conductance can be suppressed low. On the other hand, as the amount of heat inputted is increased, the incondensible gases are compressed, the heat conduction area of the condensation portion is increased and a heat conductance is increased to conduct self-control so as to increase heat transfer performance of the heat pipe. Then, the liquid condensate is recycled to the evaporation portion by spontaneous dripping of the condensate itself without wick, thereby enabling to conduct automatic switching so as to increase the heat dissipation amount to maximum. (N.H.)

  1. Pollutant removal in subsurface wastewater infiltration systems with ...

    African Journals Online (AJOL)

    Ninety-five per cent of decentralized wastewater around the ... Organic pollutant and nitrogen removal performance of SWISs ... a rubber hose with flow rate control valves. .... the limitation of oxygen became more obvious, and resulted in. 4. 3.

  2. Development of the environmental management integrated baseline at the Idaho National Engineering Laboratory using systems engineering

    International Nuclear Information System (INIS)

    Murphy, J.A.; Caliva, R.M.; Wixson, J.R.

    1997-01-01

    The Idaho National Engineering Laboratory (INEL) is one of many Department of Energy (DOE) national laboratories that has been performing environmental cleanup and stabilization, which was accelerated upon the end of the cold war. In fact, the INEL currently receives two-thirds of its scope to perform these functions. However, the cleanup is a highly interactive system that creates an opportunity for systems engineering methodology to be employed. At the INEL, a group called EM (Environmental Management) Integration has been given this charter along with a small core of systems engineers. This paper discusses the progress to date of converting the INEL legacy system into one that uses the systems engineering discipline as the method to ensure that external requirements are met

  3. Baseline autonomic nervous system arousal and physical and relational aggression in preschool: the moderating role of effortful control.

    Science.gov (United States)

    Gower, Amy L; Crick, Nicki R

    2011-09-01

    The current study investigates whether established associations between physical aggression and low autonomic nervous system arousal, as indexed by heart rate and blood pressure, also apply to the study of the development of relational aggression. Baseline heart rate and blood pressure were collected in two samples of preschoolers, and teachers reported on classroom physical and relational aggression. In Study 1, lower systolic and diastolic blood pressure were related to increased engagement in relational aggression among older preschoolers. In Study 2, lower heart rate and blood pressure predicted increased engagement in classroom physical and relational aggression concurrently and across a preschool year in some cases. Low baseline arousal-aggression associations were strongest for children with poorer self-regulation abilities, whereas high self-regulation appeared to protect children with low heart rate and blood pressure from engagement in aggressive classroom behavior. These findings suggest the utility of examining baseline physiological measures in the study of relational aggression as well as physical aggression. Implications for interventions targeted to physical and relational aggression in early childhood are discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Status report of the baseline collimation system of CLIC. Part I

    CERN Document Server

    Resta-Lopez, J.; Dalena, B.; Fernandez-Hernando, J.L.; Jackson, F.; Schulte, D.; Seryi, A.; Tomas, R.

    2011-01-01

    Important efforts have recently been dedicated to the characterisation and improvement of the design of the post-linac collimation system of the Compact Linear Collider (CLIC). This system consists of two sections: one dedicated to the collimation of off-energy particles and another one for betatron collimation. The energy collimation system is further conceived as protection system against damage by errant beams. In this respect, special attention is paid to the optimisation of the energy collimator design. The material and the physical parameters of the energy collimators are selected to withstand the impact of an entire bunch train. Concerning the betatron collimation section, different aspects of the design have been optimised: the transverse collimation depths have been recalculated in order to reduce the collimator wakefield effects while maintaining a good efficiency in cleaning the undesired beam halo; the geometric design of the spoilers has been reviewed to minimise wakefields; in addition, the opti...

  5. Status report of the baseline collimation system of CLIC. Part II

    CERN Document Server

    Resta-Lopez, J.; Dalena, B.; Fernandez-Hernando, J.L.; Jackson, F.; Schulte, D.; Seryi, A.; Tomas, R.

    2011-01-01

    Important efforts have recently been dedicated to the characterisation and improvement of the design of the post-linac collimation system of the Compact Linear Collider (CLIC). This system consists of two sections: one dedicated to the collimation of off-energy particles and another one for betatron collimation. The energy collimation system is further conceived as protection system against damage by errant beams. In this respect, special attention is paid to the optimisation of the energy collimator design. The material and the physical parameters of the energy collimators are selected to withstand the impact of an entire bunch train. Concerning the betatron collimation section, different aspects of the design have been optimised: the transverse collimation depths have been recalculated in order to reduce the collimator wakefield effects while maintaining a good efficiency in cleaning the undesired beam halo; the geometric design of the spoilers has been reviewed to minimise wakefields; in addition, the opti...

  6. Program reference schedule baseline

    International Nuclear Information System (INIS)

    1986-07-01

    This Program Reference Schedule Baseline (PRSB) provides the baseline Program-level milestones and associated schedules for the Civilian Radioactive Waste Management Program. It integrates all Program-level schedule-related activities. This schedule baseline will be used by the Director, Office of Civilian Radioactive Waste Management (OCRWM), and his staff to monitor compliance with Program objectives. Chapter 1 includes brief discussions concerning the relationship of the PRSB to the Program Reference Cost Baseline (PRCB), the Mission Plan, the Project Decision Schedule, the Total System Life Cycle Cost report, the Program Management Information System report, the Program Milestone Review, annual budget preparation, and system element plans. Chapter 2 includes the identification of all Level 0, or Program-level, milestones, while Chapter 3 presents and discusses the critical path schedules that correspond to those Level 0 milestones

  7. Base-line data analysis of a developing geothermal system, Boise, Idaho

    Energy Technology Data Exchange (ETDEWEB)

    Waag, C.J.; Wood, S.H.

    1985-09-01

    The report covers a geothermal system and calculated aquifer transmissivities in the Boise Warm Springs Water District portion of the geothermal system range from 3500-25,000 gals/day/ft. Withdrawals during the 1984-1985 heating season stabilized drawdown at the pumpbowls, and water levels approached stability in observation wells as distant as 1675 ft (507.6m). In the near steady-state condition, recharge, and water from storage beyond the observation wells provided a maximum Q of 840 gpm.

  8. Nuclear power plant equipped with hydrogen removing system

    International Nuclear Information System (INIS)

    Ezawa, Shin-ichi; Yamanari, Shozo; Okura, Minoru; Kamizuma, Nobuaki.

    1998-01-01

    A γ-shield and container spray pipelines are disposed to an upper dry well in a reactor container incorporating a reactor pressure vessel. A plurality of catalytic hydrogen removing devices are disposed close to a wall on the side of the pressure vessel in the dry well and a wall on the side of the outer wall of the reactor container. The plurality of catalytic hydrogen removing devices are disposed substantially equally in horizontal direction and circumferential direction of the side walls. If container spray water is sprayed, the atmospheric gases in the reactor are compulsory circulated. In addition, since the temperature of the γ-shield is higher than the atmospheric temperature, spontaneous circulation is caused. As a result, rising currents of gases are formed at regions in the vicinity of the γ-shield. The catalytic hydrogen removing devices are disposed to the places where the rising currents are formed. (I.N.)

  9. Software configuration management plan for the TWRS controlled baseline database system [TCBD

    International Nuclear Information System (INIS)

    Spencer, S.G.

    1998-01-01

    LHMC, TWRS Business Management Organization (BMO) is designated as system owner, operator, and maintenance authority. The TWAS BMO identified the need for the TCBD. The TWRS BMO users have established all requirements for the database and are responsible for maintaining database integrity and control (after the interface data has been received). Initial interface data control and integrity is maintained through functional and administrative processes and is the responsibility of the database owners who are providing the data. The specific groups within the TWRS BMO affected by this plan are the Financial Management and TWRS Management Support Project, Master Planning, and the Financial Control Integration and Reporting. The interfaces between these organizations are through normal line management chain of command. The Master Planning Group is assigned the responsibility to continue development and maintenance of the TCBD. This group maintains information that includes identification of requirements and changes to those requirements in a TCBD project file. They are responsible for the issuance, maintenance, and change authority of this SCW. LHMC, TWRS TCBD Users are designated as providing the project's requirement changes for implementation and also testing of the TCBD during development. The Master Planning Group coordinates and monitors the user's requests for system requirements (new/existing) as well as beta and acceptance testing. Users are those individuals and organizations needing data or information from the TCBD and having both a need-to-know and the proper training and authority to access the database. Each user or user organization is required to comply with the established requirements and procedures governing the TCBD. Lockheed Martin Services, Inc. (LMSI) is designated the TCBD developer, maintainer, and custodian until acceptance and process testing of the system has been completed via the TWRS BMO. Once this occurs, the TCBD will be completed and

  10. The systemic lupus erythematosus travel burden survey: baseline data among a South Carolina cohort.

    Science.gov (United States)

    Williams, Edith M; Ortiz, Kasim; Zhang, Jiajia; Zhou, Jie; Kamen, Diane

    2016-04-29

    Many studies on the impact of systemic lupus erythematosus or lupus have identified patient travel costs as being problematic. We administered a survey that examined the impact of self-rated travel burden on lupus patients. The systemic lupus erythematosus travel burden survey included 41 patients enrolled in the systemic lupus erythematosus database project at the Medical University of South Carolina. Most participants reported that travel caused medications to be discontinued or appointments to be missed. In unadjusted logistic regressions of the relationship between these outcomes and medical travel burden, both distance to rheumatologists and time to lupus medical care were significant. Our findings suggest that more research is needed to examine the influence of travel burden among this population, but data from this report could help to inform physicians, academic researchers, and other health professionals in South Carolina and other areas with significant rural populations on how travel burden may impact patients receiving care for lupus and provide an opportunity for the development of interventions aimed at assisting lupus patients with management of stressors related to travel burden.

  11. Registration Combining Wide and Narrow Baseline Feature Tracking Techniques for Markerless AR Systems

    Directory of Open Access Journals (Sweden)

    Bo Yang

    2009-12-01

    Full Text Available Augmented reality (AR is a field of computer research which deals with the combination of real world and computer generated data. Registration is one of the most difficult problems currently limiting the usability of AR systems. In this paper, we propose a novel natural feature tracking based registration method for AR applications. The proposed method has following advantages: (1 it is simple and efficient, as no man-made markers are needed for both indoor and outdoor AR applications; moreover, it can work with arbitrary geometric shapes including planar, near planar and non planar structures which really enhance the usability of AR systems. (2 Thanks to the reduced SIFT based augmented optical flow tracker, the virtual scene can still be augmented on the specified areas even under the circumstances of occlusion and large changes in viewpoint during the entire process. (3 It is easy to use, because the adaptive classification tree based matching strategy can give us fast and accurate initialization, even when the initial camera is different from the reference image to a large degree. Experimental evaluations validate the performance of the proposed method for online pose tracking and augmentation.

  12. Thermoelectric Generators for Automotive Waste Heat Recovery Systems Part I: Numerical Modeling and Baseline Model Analysis

    Science.gov (United States)

    Kumar, Sumeet; Heister, Stephen D.; Xu, Xianfan; Salvador, James R.; Meisner, Gregory P.

    2013-04-01

    A numerical model has been developed to simulate coupled thermal and electrical energy transfer processes in a thermoelectric generator (TEG) designed for automotive waste heat recovery systems. This model is capable of computing the overall heat transferred, the electrical power output, and the associated pressure drop for given inlet conditions of the exhaust gas and the available TEG volume. Multiple-filled skutterudites and conventional bismuth telluride are considered for thermoelectric modules (TEMs) for conversion of waste heat from exhaust into usable electrical power. Heat transfer between the hot exhaust gas and the hot side of the TEMs is enhanced with the use of a plate-fin heat exchanger integrated within the TEG and using liquid coolant on the cold side. The TEG is discretized along the exhaust flow direction using a finite-volume method. Each control volume is modeled as a thermal resistance network which consists of integrated submodels including a heat exchanger and a thermoelectric device. The pressure drop along the TEG is calculated using standard pressure loss correlations and viscous drag models. The model is validated to preserve global energy balances and is applied to analyze a prototype TEG with data provided by General Motors. Detailed results are provided for local and global heat transfer and electric power generation. In the companion paper, the model is then applied to consider various TEG topologies using skutterudite and bismuth telluride TEMs.

  13. Removal of pharmaceuticals and personal care products in aquatic plant-based systems: A review

    International Nuclear Information System (INIS)

    Zhang, Dongqing; Gersberg, Richard M.; Ng, Wun Jern; Tan, Soon Keat

    2014-01-01

    Pharmaceuticals and personal care products (PPCPs) in the aquatic environment are regarded as emerging contaminants and have attracted increasing concern. The use of aquatic plant-based systems such as constructed wetlands (CWs) for treatment of conventional pollutants has been well documented. However, available research studies on aquatic plant-based systems for PPCP removal are still limited. The removal of PPCPs in CWs often involves a diverse and complex set of physical, chemical and biological processes, which can be affected by the design and operational parameters selected for treatment. This review summarizes the PPCP removal performance in different aquatic plant-based systems. We also review the recent progress made towards a better understanding of the various mechanisms and pathways of PPCP attenuation during such phytoremediation. Additionally, the effect of key CW design characteristics and their interaction with the physico-chemical parameters that may influence the removal of PPCPs in functioning aquatic plant-based systems is discussed. -- Highlights: • Investigation of the removal performance of PPCPs in CW systems. • Investigation of the mechanisms and pathways contributing to PPCP removal in CWs. • Investigation of the effect of CW design parameters on PPCP removal. • Investigation of the correlation between physico-chemical parameters and PPCP removal. -- This review gives an overview of the present state of research on the removal of pharmaceutical and personal care products by means of constructed wetlands

  14. Multiple fMRI system-level baseline connectivity is disrupted in patients with consciousness alterations.

    Science.gov (United States)

    Demertzi, Athena; Gómez, Francisco; Crone, Julia Sophia; Vanhaudenhuyse, Audrey; Tshibanda, Luaba; Noirhomme, Quentin; Thonnard, Marie; Charland-Verville, Vanessa; Kirsch, Murielle; Laureys, Steven; Soddu, Andrea

    2014-03-01

    In healthy conditions, group-level fMRI resting state analyses identify ten resting state networks (RSNs) of cognitive relevance. Here, we aim to assess the ten-network model in severely brain-injured patients suffering from disorders of consciousness and to identify those networks which will be most relevant to discriminate between patients and healthy subjects. 300 fMRI volumes were obtained in 27 healthy controls and 53 patients in minimally conscious state (MCS), vegetative state/unresponsive wakefulness syndrome (VS/UWS) and coma. Independent component analysis (ICA) reduced data dimensionality. The ten networks were identified by means of a multiple template-matching procedure and were tested on neuronality properties (neuronal vs non-neuronal) in a data-driven way. Univariate analyses detected between-group differences in networks' neuronal properties and estimated voxel-wise functional connectivity in the networks, which were significantly less identifiable in patients. A nearest-neighbor "clinical" classifier was used to determine the networks with high between-group discriminative accuracy. Healthy controls were characterized by more neuronal components compared to patients in VS/UWS and in coma. Compared to healthy controls, fewer patients in MCS and VS/UWS showed components of neuronal origin for the left executive control network, default mode network (DMN), auditory, and right executive control network. The "clinical" classifier indicated the DMN and auditory network with the highest accuracy (85.3%) in discriminating patients from healthy subjects. FMRI multiple-network resting state connectivity is disrupted in severely brain-injured patients suffering from disorders of consciousness. When performing ICA, multiple-network testing and control for neuronal properties of the identified RSNs can advance fMRI system-level characterization. Automatic data-driven patient classification is the first step towards future single-subject objective diagnostics

  15. Removal by irradiation of alcohols in micellar systems

    International Nuclear Information System (INIS)

    Moreno, A.J.; Mijata, T.; Arai, H.

    2003-01-01

    Mixtures of ortho-chloro phenol and butanol of 40 mg L -1 in aqueous solution in presence of the surfactant dodecyl sulfate of sodium (1 to 9 m mol L -1 ) were irradiated at 2 and 5 kGy of gamma radiation. The quantitative analysis of the irradiated and not irradiated samples carries out by gas chromatography. It was determined that the surfactant exercises a protection effect in the radiolytic removal of the studied alcohols. In general terms this it increases in function of the concentration of the surfactant. However, competition reactions exist among the substrate and some reactive species produced by the radiolysis of the water that in some moment exercise a positive catalytic effect in the removal of the substrate. (Author)

  16. Hybrid disposal systems and nitrogen removal in individual sewage disposal systems

    Energy Technology Data Exchange (ETDEWEB)

    Franks, A.L.

    1993-06-01

    The use of individual disposal systems in ground-water basins that have adverse salt balance conditions and/or geologically unsuitable locations, has become a major problem in many areas of the world. There has been much research in design of systems for disposal of domestic sewage. This research includes both hybrid systems for disposal of domestic sewage. This research includes both hybrid systems for disposal of the treated waste in areas with adverse geologic conditions and systems for the removal of nitrogen and phosphorus prior to percolation to the ground water. This paper outlines the history of development and rationale for design and construction of individual sewage disposal systems and describes the designs and limitations of the hybrid and denitrification units. The disposal systems described include Mounds, Evapotranspiration and Evapotranspiration/Infiltration systems. The denitrification units include those using methanol, sulfur and limestone, gray water and secondary treated wastewater for energy sources.

  17. Evaluation of Heat Removal Performance of Passive Decay Heat Removal system for S-CO{sub 2} Cooled Micro Modular Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jangsik; Lee, Jeong Ik; Jeong, Yong Hoon [KAIST, Daejeon (Korea, Republic of)

    2015-05-15

    The modular systems is able to be transported by large trailer. Moreover, dry cooling system is applied for waste heat removal. The characteristics of MMR takes wide range of construction area from coast to desert, isolated area and disaster area. In MMR, Passive decay heat removal system (PDHRS) is necessary for taking the advantage on selection of construction area where external support cannot be offered. The PDHRS guarantees to protect MMR without external support. In this research, PDHRS of MMR is introduced and decay heat removal performance is analyzed. The PDHRS guarantees integrity of reactor coolant system. The high level of decay heat (2 MW) can be removed by PDHRS without offsite power.

  18. Anaerobic bacterial systems result in the removal of soluble uranium

    International Nuclear Information System (INIS)

    Thomson, B.M.; Barton, L.L.; Steenhoudt, K.; Tucker, M.D.

    1994-01-01

    Sulfate-reducing bacteria, nitrate-reducing bacteria and bacteria present in sewage sludge were examined for their ability to reduce the level of soluble U(VI) in enriched media. Cultures of Desulfovibrio desulfuricans, D. gigas, and D. vulgaris were grown in sulfate-containing media while Pseudomonas putida and P. denitrificans were cultivated in nitrate media. The amount of U(VI) removed from solution was dependent on metabolism because greater levels of uranium were removed when U(VI) was added to a growing culture than when added to a culture in stationary phase. The presence of vanadate, arsenate, selenate or molybdate at 0.1 and 0.01 M levels in sulfate-reducing cultures, nitrate-respiring cultures or in sludge cultures did not have an effect on the amount of uranium removed. In all cultures the amount of uranium in solution was markedly reduced after 10 to 20 days and reduced uranium, as U(IV), was detected in several cultures. Present in the cultures of D. desulfuricans were crystals of uranium. Examination of these cultures by electron microscopy indicates that the uranium (IV) is deposited outside of the cell and these needle-like crystals are associated with cellular material. X-ray probe analysis with the electron microscope gave an image that was in close agreement with U(IV). With D. desulfuricans in a continuous stirred tank reactor, kinetic parameters have been calculated for uranium reduction. Over a period of 20 to 60 hours, the amount of soluble uranium removed from the bioreactor was proportional to residence time over a period of 20 to 60 hours

  19. After-heat removal system of fast reactor

    International Nuclear Information System (INIS)

    Otsuka, Masaya; Shibata, Yoji; Ikeda, Takashi; Iwashige, Kengo; Yoneda, Yoshiyuki.

    1988-01-01

    Purpose: To remove after-heat by natural convection without disposing a movable portion even in a large-scaled reactor. Constitution: The exit of a reactor wall air-cooling duct disposed to the outside of a safety vessel is connected to the secondary inlet of an air cooler that conducts heat exchange with sodium in a high temperature plenum. That is, after-heat is removed only through the natural convection by a structure in which the reactor wall air-cooling duct and the secondary side of the air cooler are connected in series. Air exhausted from the exit of the air-cooling duct by the air cooler is further heated with sodium in the high temperature plenum. The flow rate of air flowing through the air-cooling duct is increased as compared with the case where the air cooler is not present. Accordingly, the flow rate of air at low temperature flowing through the inlet of the air duct is increased to increase the heat conduction amount. In this way, after-heat can be removed only by means of natural convection without providing movable portions even in a large-scaled reactor with the thermal power in excess of 2,000 MW. (Horiuchi, T.)

  20. Nitrogen removal and microbial communities in a three-stage system simulating a riparian environment.

    Science.gov (United States)

    Wang, Ziyuan; Wang, Zhixin; Pei, Yuansheng

    2014-06-01

    The riparian zone is an active interface for nitrogen removal, in which nitrogen transformations by microorganisms have not been valued. In this study, a three-stage system was constructed to simulate the riparian zone environments, and nitrogen removal as well as the microbial community was investigated in this 'engineered riparian system'. The results demonstrated that stage 1 of this system accounted for 41-51 % of total nitrogen removal. Initial ammonium loading and redox potential significantly impacted the nitrogen removal performances. Stages 1 and 2 were both composed of an anoxic/oxic (A/O) zone and an anaerobic column. The A/O zone removed most of the ammonium load (6.8 g/m(2)/day), while the anaerobic column showed a significant nitrate removal rate (11.1 g/m(2)/day). Molecular biological analysis demonstrated that bacterial diversity was high in the A/O zones, where ammonium-oxidizing bacteria and nitrite-oxidizing bacteria accounted for 8.42 and 3.32 % of the bacterial population, respectively. The denitrifying bacteria Acidovorax sp. and the nitrifying bacteria Nitrosospira/Nitrosomonas were the predominant microorganisms in this engineered riparian system. This three-stage system was established to achieve favorable nitrogen removal and the microbial community in the system was also retained. This investigation should deepen our understanding of biological nitrogen removal in engineered riparian zones.

  1. Experimental and analytical studies of a passive shutdown heat removal system for advanced LMRs

    International Nuclear Information System (INIS)

    Heineman, J.; Kraimer, M.; Lottes, P.; Pedersen, D.; Stewart, R.; Tessier, J.

    1988-01-01

    A facility designed and constructed to demonstrate the viability of natural convection passive heat removal systems as a key feature of innovative LMR Shutdown Heat Removal (SHR) systems is in operation at Argonne National Laboratory (ANL). This Natural Convection Shutdown Heat Removal Test Facility (NSTF) is being used to investigate the heat transfer performance of the GE/PRISM and the RI/SAFR passive designs. This paper presents a description of the NSTF, the pretest analysis of the Radiant Reactor Vessel Auxiliary Cooling System (RVACS) in support of the GE/PRISM IFR concept, and experiment results for the RVACS simulation. Preliminary results show excellent agreement with predicted system performance

  2. Experimental and analytical studies of a passive shutdown heat removal system for advanced LMRs

    Energy Technology Data Exchange (ETDEWEB)

    Heineman, J.; Kraimer, M.; Lottes, P.; Pedersen, D.; Stewart, R.; Tessier, J.

    1988-01-01

    A facility designed and constructed to demonstrate the viability of natural convection passive heat removal systems as a key feature of innovative LMR Shutdown Heat Removal (SHR) systems is in operation at Argonne National Laboratory (ANL). This Natural Convection Shutdown Heat Removal Test Facility (NSTF) is being used to investigate the heat transfer performance of the GE/PRISM and the RI/SAFR passive designs. This paper presents a description of the NSTF, the pretest analysis of the Radiant Reactor Vessel Auxiliary Cooling System (RVACS) in support of the GE/PRISM IFR concept, and experiment results for the RVACS simulation. Preliminary results show excellent agreement with predicted system performance.

  3. Management of the baseline shift using a new and simple method for respiratory-gated radiation therapy: Detectability and effectiveness of a flexible monitoring system

    International Nuclear Information System (INIS)

    Tachibana, Hidenobu; Kitamura, Nozomi; Ito, Yasushi; Kawai, Daisuke; Nakajima, Masaru; Tsuda, Akihisa; Shiizuka, Hisao

    2011-01-01

    Purpose: In respiratory-gated radiation therapy, a baseline shift decreases the accuracy of target coverage and organs at risk (OAR) sparing. The effectiveness of audio-feedback and audio-visual feedback in correcting the baseline shift in the breathing pattern of the patient has been demonstrated previously. However, the baseline shift derived from the intrafraction motion of the patient's body cannot be corrected by these methods. In the present study, the authors designed and developed a simple and flexible system. Methods: The system consisted of a web camera and a computer running our in-house software. The in-house software was adapted to template matching and also to no preimage processing. The system was capable of monitoring the baseline shift in the intrafraction motion of the patient's body. Another marker box was used to monitor the baseline shift due to the flexible setups required of a marker box for gated signals. The system accuracy was evaluated by employing a respiratory motion phantom and was found to be within AAPM Task Group 142 tolerance (positional accuracy <2 mm and temporal accuracy <100 ms) for respiratory-gated radiation therapy. Additionally, the effectiveness of this flexible and independent system in gated treatment was investigated in healthy volunteers, in terms of the results from the differences in the baseline shift detectable between the marker positions, which the authors evaluated statistically. Results: The movement of the marker on the sternum [1.599 ± 0.622 mm (1 SD)] was substantially decreased as compared with the abdomen [6.547 ± 0.962 mm (1 SD)]. Additionally, in all of the volunteers, the baseline shifts for the sternum [-0.136 ± 0.868 (2 SD)] were in better agreement with the nominal baseline shifts than was the case for the abdomen [-0.722 ± 1.56 mm (2 SD)]. The baseline shifts could be accurately measured and detected using the monitoring system, which could acquire the movement of the marker on the sternum. The

  4. System for removing sludges from a steam generator

    International Nuclear Information System (INIS)

    Hickman, R.A.; Tolino, R.W.

    1977-01-01

    The invention relates to a process for removing sludge from a steam generator comprising a tube plate at the bottom end of a cylinder and a cluster of heat exchange tubes fitted to this tube plate and extending upwards from it. The cylinder has an access opening above this tube plate. A liquid jet is applied at a tangent to the cylinder above the tube plate so as to form a cicumferential flow of liquid at the external end of this plate. This flow is taken up and sucked out of the cylinder by a suction appliance and, at the same time, a nozzle with holes for liquid jets is moved crosswise to these tubes above the tube plate whilst directing a liquid jet against the tubes and towards the cicumferential liquid flow so as to wash away any deposits detached from the lower ends of the tubes and located in this circular flow of liquid to be immediately removed by the suction appliance [fr

  5. Modelling Cr(VI) removal by a combined carbon-activated sludge system

    International Nuclear Information System (INIS)

    Orozco, A. Micaela Ferro; Contreras, Edgardo M.; Zaritzky, Noemi E.

    2008-01-01

    The combined carbon-activated sludge process has been proposed as an alternative to protect the biomass against toxic substances in wastewaters; however, the information about the effect of powdered-activated carbon (PAC) addition in activated sludge reactors for the treatment of wastewaters containing Cr(VI) is limited. The objectives of the present study were: (a) to evaluate the removal of hexavalent chromium by (i) activated sludge microorganisms in aerobic batch reactors, (ii) powdered-activated carbon, and (iii) the combined action of powdered-activated carbon and biomass; (b) to propose mathematical models that interpret the experimental results. Different Cr(VI) removal systems were tested: (S1) biomass (activated sludge), (S2) PAC, and (S3) the combined activated carbon-biomass system. A Monod-based mathematical model was used to describe the kinetics of Cr(VI) removal in the system S1. A first-order kinetics with respect to Cr(VI) and PAC respectively, was proposed to model the removal of Cr(VI) in the system S2. Cr(VI) removal in the combined carbon-biomass system (S3) was faster than both Cr(VI) removal using PAC or activated sludge individually. Results showed that the removal of Cr(VI) using the activated carbon-biomass system (S3) was adequately described by combining the kinetic equations proposed for the systems S1 and S2

  6. BOA II: Asbestos Pipe-Insulation Removal Robot System. Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    None

    2001-01-01

    The objective of this task is to develop and demonstrate a mechanical, asbestos-removal system that can be remotely operated without a containment area. The technology, known as BOA, consists of a pipe-crawler removal head and a boom vehicle system with dual robots. BOA's removal head can be remotely placed on the outside of the pipe and can crawl along the pipe, removing lagging and insulation. The lagging and insulation is cut using a hybrid endmill water-jet cutter and then diced into 2-inch cube sections of ACM. These ACM sections are then removed from the pipe using a set of blasting fan- spray nozzles, vacuumed off through a vacuum hose, and bagged. Careful attention to vacuum and entrapment air flow ensures that the system can operate without a containment area while meeting local and federal standards for fiber count

  7. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications.

    Science.gov (United States)

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; den Heeten, Gerard; Karssemeijer, Nico

    2016-04-01

    In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists' detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8-1.0 were

  8. Development of metal catalyst impregnation technology for membrane-based oxygen removal system

    International Nuclear Information System (INIS)

    Kim, Mun Soo; Lee, Doo Ho; Kang, Duk Won

    2005-01-01

    Dissolved oxygen(DO) is a primary cause of PWSCC and its content in reactor coolant system in NPPs has been strictly controlled by various DO removal methods. There are several removal methods of DO, such as vacuum degasification, thermal deaeration, and reductive removal by oxygen scavengers. Although the operation principles of vacuum degasification and thermal deaeration are simple, these methods require a lot of energy for operation and show lower efficiency. And these methods have a few handicaps such as temperature, pH, toxicity, high cost of installation and so on. For the purpose of developing the best method for DO removal from make-up water storage tank, it is necessary to overcome the disadvantages of hydrazine treatment. From this point of view, membrane-based oxygen removal system (MORS) has many advantages than other methods for example, friendly environmental process, versatility of operation conditions with high temperature and low pressure, small space, low cost, etc. Recently de-gassing membrane is widely used in power plant's feed water system for DO removal. De-gassing membrane has some advantages; it removes other dissolved gases such as CO2, N2, as well as O2, and is more economical than Catalytic resin-based Oxygen Removal System. In this study, to obtain better efficiency of MORS, we modified the polypropylene (PP) hollow fiber membrane by plasma treatment and ion beam irradiation supported platinum(Pt), palladium(Pd) as metal catalyst on the surface of the membrane

  9. Results from evaporation tests to support the MWTF heat removal system design

    International Nuclear Information System (INIS)

    Crea, B.A.

    1994-01-01

    An experimental tests program was conducted to measure the evaporative heat removal from the surface of a tank of simulated waste. The results contained in this report constitute definition design data for the latest heat removal function of the MWTF primary ventilation system

  10. Numerical modeling analysis of VOC removal processes in different aerobic vertical flow systems for groundwater remediation

    NARCIS (Netherlands)

    De Biase, C.; Carminati, A.; Oswald, S.E.; Thullner, M.

    2013-01-01

    Vertical flow systems filled with porous medium have been shown to efficiently remove volatile organic contaminants (VOCs) from contaminated groundwater. To apply this semi-natural remediation strategy it is however necessary to distinguish between removal due to biodegradation and due to volatile

  11. Capital and Operating Cost of Small Arsenic Removal System and their Most Frequent Maintenance Problems

    Science.gov (United States)

    This presentation will first summarize the capital and operating cost of treatment systems by type and size of the systems. The treatment systems include adsorptive media (AM) systems, iron removal (IR), coagulation/filtration (CF), ion exchange (IX) systems, and point-of-use rev...

  12. Improvements in iodine and ruthenium removal from advanced liquid processing system

    Energy Technology Data Exchange (ETDEWEB)

    Skibo, A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-09-27

    SRNL has considerable experience in designing, engineering, and operating systems for removing iodine-129 (I-129) and ruthenium-106 (Ru-106) from waste streams that are directly analogous to the Advanced Liquid Processing System (ALPS) waste streams. SRNL proposes to provide the technical background and design and engineering support for an improved I-129 and Ru-106 removal system for application to ALPS on the Fukushima Daiichi Nuclear Power Station (NPS).

  13. 300 GPM Solids Removal System A True Replacement for Back Flushable Powdered Filter Systems - 13607

    Energy Technology Data Exchange (ETDEWEB)

    Ping, Mark R.; Lewis, Mark [EnergySolutions, Suite 100, Center Point II, 100 Center Point Circle, Columbia, SC 29210 (United States)

    2013-07-01

    The EnergySolutions Solids Removal System (SRS) utilizes stainless steel cross-flow ultra-filtration (XUF) technology which allows it to reliably remove suspended solids greater than one (1) micron from liquid radwaste streams. The SRS is designed as a pre-treatment step for solids separation prior to processing through other technologies such as Ion Exchange Resin (IER) and/or Reverse Osmosis (RO), etc. Utilizing this pre-treatment approach ensures successful production of reactor grade water while 1) decreasing the amount of radioactive water being discharged to the environment; and 2) decreasing the amount of radioactive waste that must ultimately be disposed of due to the elimination of spent powdered filter media. (authors)

  14. 300 GPM Solids Removal System A True Replacement for Back Flushable Powdered Filter Systems - 13607

    International Nuclear Information System (INIS)

    Ping, Mark R.; Lewis, Mark

    2013-01-01

    The EnergySolutions Solids Removal System (SRS) utilizes stainless steel cross-flow ultra-filtration (XUF) technology which allows it to reliably remove suspended solids greater than one (1) micron from liquid radwaste streams. The SRS is designed as a pre-treatment step for solids separation prior to processing through other technologies such as Ion Exchange Resin (IER) and/or Reverse Osmosis (RO), etc. Utilizing this pre-treatment approach ensures successful production of reactor grade water while 1) decreasing the amount of radioactive water being discharged to the environment; and 2) decreasing the amount of radioactive waste that must ultimately be disposed of due to the elimination of spent powdered filter media. (authors)

  15. After-heat removing system in FBR type reactor

    International Nuclear Information System (INIS)

    Goto, Tadashi; Inoue, Kotaro; Yamakawa, Masanori; Ikeda, Takashi.

    1988-01-01

    Purpose: To promote more positive forcive circulation of primary circuit fluids thereby increase the heat removing amount. Constitution: The primary side of an electromagnetic flow coupler type heat exchanger is opened to the primary fluid of a reactor, while the secondary side is connected with the secondary circuit comprising an air cooler and an electromagnetic pump. Since the secondary circuit stands-by during normal operation, the electromagnetic flow coupler does not operate and does not generate force for flowing primary circuit fluid. If flow due to the external force to the primary circuit fluid should occur in the electromagnetic flow coupler type heat exchanger, an electromagnetic force tending to flow the secondary circuit fluid is exerted oppositely. However the coupler undergoes reaction inertia of the fluid or flowing resistance, to exert in the direction of suppressing the flow, thereby prevent the heat loss. (Yoshihara, H.)

  16. Retrofitting of activated charcoal filters in the iodine removal system of Cirus reactor

    International Nuclear Information System (INIS)

    Arora, M.K.; Thomas, Shibu; Ullas, O.P.; Sharma, V.K.; Singh, Kapil Deo S.

    2002-01-01

    Full text: The emergency exhaust system for removal of iodine in the 40 MWt Cirus reactor consisted of a caustic scrubber followed by a bank of silver-coated copper mesh filters. The latter filter elements are no longer commercially available, and moreover, there is need to upgrade the system to meet the current safety norms. An iodine removal system based on activated charcoal adsorbers has been selected for this purpose. The design of the system ensures high iodine removal efficiency and thermal safety of the filters for a postulated accident condition beyond design basis accident. The new iodine removal system has been retrofitted during the current refurbishing programme of Cirus and it has been commissioned and tested satisfactorily

  17. Optimization of the Carbon Dioxide Removal Assembly (CDRA-4EU) in Support of the International Space System and Advanced Exploration Systems

    Science.gov (United States)

    Knox, James C.; Stanley, Christine M.

    2015-01-01

    The Life Support Systems Project (LSSP) under the Advanced Exploration Systems (AES) program builds upon the work performed under the AES Atmosphere Resource Recovery and Environmental Monitoring (ARREM) project focusing on the numerous technology development areas. The Carbon Dioxide (CO2) removal and associated air drying development efforts are focused on improving the current state-of-the-art system on the International Space Station (ISS) utilizing fixed beds of sorbent pellets by seeking more robust pelletized sorbents, evaluating structured sorbents, and examining alternate bed configurations to improve system efficiency and reliability. A component of the CO2 removal effort utilizes a virtual Carbon Dioxide Removal Assembly, revision 4 (CDRA-4) test bed to test a large number of potential operational configurations with independent variations in flow rate, cycle time, heater ramp rate, and set point. Initial ground testing will provide prerequisite source data and provide baseline data in support of the virtual CDRA. Once the configurations with the highest performance and lowest power requirements are determined by the virtual CDRA, the results will be confirmed by testing these configurations with the CDRA-4EU ground test hardware. This paper describes the initial ground testing of select configurations. The development of the virtual CDRA under the AES-LSS Project will be discussed in a companion paper.

  18. Mathematical modeling based evaluation and simulation of boron removal in bioelectrochemical systems

    Energy Technology Data Exchange (ETDEWEB)

    Ping, Qingyun [Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA 24061 (United States); Abu-Reesh, Ibrahim M. [Department of Chemical Engineering, College of Engineering, Qatar University, P.O. Box 2713, Doha (Qatar); He, Zhen, E-mail: zhenhe@vt.edu [Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA 24061 (United States)

    2016-11-01

    Boron removal is an arising issue in desalination plants due to boron's toxicity. As an emerging treatment concept, bioelectrochemical systems (BES) can achieve potentially cost-effective boron removal by taking advantage of cathodic-produced alkali. Prior studies have demonstrated successful removal of boron in microbial desalination cells (MDCs) and microbial fuel cells (MFCs), both of which are representative BES. Herein, mathematical models were developed to further evaluate boron removal by different BES and understand the key operating factors. The models delivered very good prediction of the boron concentration in the MDC integrated with Donnan Dialysis (DD) system with the lowest relative root-mean-square error (RMSE) of 0.00%; the predication of the MFC performance generated the highest RMSE of 18.55%. The model results of salt concentration, solution pH, and current generation were well fitted with experimental data for RMSE values mostly below 10%. The long term simulation of the MDC-DD system suggests that the accumulation of salt in the catholyte/stripping solution could have a positive impact on the removal of boron due to osmosis-driven convection. The current generation in the MDC may have little influence on the boron removal, while in the MFC the current-driven electromigration can contribute up to 40% of boron removal. Osmosis-induced convection transport of boron could be the major driving force for boron removal to a low level < 2 mg L{sup −} {sup 1}. The ratio between the anolyte and the catholyte flow rates should be kept > 22.2 in order to avoid boron accumulation in the anolyte effluent. - Highlights: • Mathematical models are developed to understand boron removal in BES. • Boron removal can be driven by electromigration induced by current generation. • Diffusion induced by a salt concentration gradient also contributes to boron removal. • Osmosis and current driven convection transport play diverse roles in different BES.

  19. Experimental investigation on improving the removal effect of WFGD system on fine particles by heterogeneous condensation

    Energy Technology Data Exchange (ETDEWEB)

    Bao, Jingjing; Yang, Linjun; Yan, Jinpei; Xiong, Guilong; Shen, Xianglin [Southeast Univ., Nanjing (China). School of Energy and Environment

    2013-07-01

    Heterogeneous condensation of water vapor as a preconditioning technique for the removal of fine particles from flue gas was investigated experimentally in a wet flue gas desulfurization (WFGD) system. A supersaturated vapor phase, necessary for condensational growth of fine particles, was achieved in the SO{sub 2} absorption zone and at the top of the wet FGD scrubber by adding steam in the gas inlet and above the scrubbing liquid inlet of the scrubber, respectively. The condensational grown droplets were then removed by the scrubbing liquid and a high-efficiency demister. The results show that the effectiveness of the WFGD system for removal of fine particles is related to the SO{sub 2} absorbent and the types of scrubber employed. Despite a little better effectiveness for the removal of fine particles in the rotating-stream-tray scrubber at the same liquid-to-gas ratio, The similar trends are obtained between the spray scrubber and rotating-stream-tray scrubber. Due to the formation of aerosol particles in the limestone and ammonia-based FGD processes, the fine particle removal efficiencies are lower than those for Na{sub 2}CO{sub 3} and water. The performance of the WFGD system for removal of fine particles can be significantly improved for both steam addition cases, for which the removal efficiency increases with increasing amount of added steam. A high liquid to gas ratio is beneficial for efficient removal of fine particles by heterogeneous condensation of water vapor.

  20. Removal of fine particles in wet flue gas desulfurization system by heterogeneous condensation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, L.J.; Bao, J.J.; Yan, J.P.; Liu, J.H.; Song, S.J.; Fan, F.X. [Southeast University, Nanjing (China). School of Energy & Environment

    2010-01-01

    A novel process to remove fine particles with high efficiency by heterogeneous condensation in a wet flue gas desulfurization (WFGD) system is presented. A supersaturated vapor phase, necessary for condensational growth of fine particles, was achieved in the SO{sub 2} absorption zone and at the top of the wet FGD scrubber by adding steam in the gas inlet and above the scrubbing liquid inlet of the scrubber, respectively. The condensational grown droplets were then removed by the scrubbing liquid and a high-efficiency demister. The results show that the effectiveness of the WFGD system for removal of fine particles is related to the SO{sub 2} absorbent employed. When using CaCO{sub 3} and NH{sub 3} {center_dot} H{sub 2}O to remove SO{sub 2} from flue gas, the fine particle removal efficiencies are lower than those for Na2CO{sub 3} and water, and the morphology and elemental composition of fine particles are changed. This effect can be attributed to the formation of aerosol particles in the limestone and ammonia-based FGD processes. The performance of the WFGD system for removal of fine particles can be significantly improved for both steam addition cases, for which the removal efficiency increases with increasing amount of added steam. A high liquid to gas ratio is beneficial for efficient removal of fine particles by heterogeneous condensation of water vapor.

  1. Development of a new decay heat removal system for a high temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Sim, Yoon Sub; Park, Rae Young; Kim, Seyun

    2007-01-01

    The heat removal capacity of a RCCS is one of the major parameters limiting the capacity of a HTGR based on a passive safety system. To improve the plant economy of a HTGR, the decay heat removal capacity needs to be improved. For this, a new analysis system of an algebraic method for the performance of various RCCS designs was set up and the heat transfer characteristics and performance of the designs were analyzed. Based on the analysis results, a new passive decay heat removal system with a substantially improved performance, LFDRS was developed. With the new system, one can have an expectation that the heat removal capacity of a HTGR could be doubled

  2. Highly Efficient Closed-Loop CO2 Removal System for Deep-Space ECLSS, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — TDA Research Inc.(TDA) in collaboration with University of Puerto Rico ? Mayaguez (UPRM is proposing to develop a highly efficient CO2 removal system based on UPRM...

  3. ETV REPORT: REMOVAL OF ARSENIC IN DRINKING WATER - PALL CORPORATION MICROZA. MICROFILTRATION SYSTEM

    Science.gov (United States)

    Verification testing of the Pall Corporation Microza. Microfiltration System for arsenic removal was conducted at the Oakland County Drain Commissioner (OCDC) Plum Creek Development well station located in Oakland County, Michigan from August 19 through October 8, 2004. The sourc...

  4. Advanced Product Water Removal and Management (APWR) Fuel Cell System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is a passive, self-regulating, gravity-independent Advanced Product Water Removal and management (APWR) system for incorporation into Polymer...

  5. Advanced Product Water Removal and Management (APWR) Fuel Cell System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is a passive, self-regulating, gravity-independent Advanced Product Water Removal (APWR) system for Polymer Electrolyte Membrane (PEM)...

  6. Removal of heavy-metal ions from dilute waste streams using membrane-based hybrid systems

    International Nuclear Information System (INIS)

    Friesen, D.T.; Edlund, D.J.

    1993-01-01

    At Bend research, the authors have developed hybrid systems that couple a process that removes solvent (water) and a process that removes solute (metal ions) such that toxic heavy-metal ions can be efficiently and selectively removed to very low levels while simultaneously concentrating the heavy-metal ions in relatively pure form. Although this technology is broadly applicable, the authors are focusing on the development of a system to treat groundwater that is contaminated with heavy-metal ions. The process utilizes coupled transport and reverse osmosis to reduce chromium and uranium concentration down to parts-per-billion levels

  7. Shutdown risk analysis for a BWR plant (residual heat removal systems)

    International Nuclear Information System (INIS)

    Rebollo Garcia, C.; Merino Teillet, A.; Cerezo, L.

    1994-01-01

    This report analyses the different risk situations which may arise during refuelling outage at Cofrentes NPP. The most critical situations are determined in terms of the small amount of coolant available and the lowest number of heat removal and water make-up systems available. The available times before the boiling point of the coolant is reached and the subsequent moment when the fuel elements are left uncovered in the event of the failure of the normal heat removal functions are determined. The analysis identifies the alternative systems which can be used besides those required by the technical specification and their capacity for residual heat removal and coolant make-up functions. (Author)

  8. Organic Removal Efficiency of the Nanofiltration and Adsorption Hybrid System in High Strength Wastewater

    Directory of Open Access Journals (Sweden)

    Amir Hessam Hassani

    2011-03-01

    Full Text Available Surface and groundwater resources are increasingly jeopardized by discharges from pharmaceutical, chemical, and detergent plants. The high pollutant load of the effluents from these industries requires specific treatments. The objective of this research was to study and compare the nanofiltration and adsorption hybrid system with the plain nanofiltration system in wastewater treatment.For this purpose, a pilot nanofiltration system with a capacity of 7.6 m3/d using 1 and 5 micron filters and a FILMTEC NF90-4040 membrane was used in the first phase of the study. In the second phase, granular activated carbon cartridges were used. Inluent and effluent discharges as well as the COD removal were measured in both systems under variable times and organic load conditions. The results showed that COD removal efficiency was higher in the hybrid system than in the plain naonofiltration one. In the hybrid system, the Maximum in the hybrid system, the COD removal efficiencies achieved for organic loads of 1000, 2000, and 3000 mg/L were 99%, 95.86%, and 92.93%, respectively. The same values for the plain nanofiltration system were 87.34%, 50%, and 29.41%, respectively. It was found that polarization and membrane fouling decreased both the effluent flow and the COD removal efficiency with time. Fouling of the membrane was, however, lower in the hybrid system compared to the plain nanofiltration; thus, the hybrid system was associated with higher values of COD removal and delayed membrane fouling.

  9. The NOvA Data Acquistion System: A highly distributed, synchronized, continuous readout system for a long baseline neutrino experiment

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    The NOvA experiment at Fermi National Accelerator Lab, has been designed and optimized to perform a suite of measurements critical to our understanding of the neutrino’s properties, their oscillations and their interactions. NOvA presents a unique set of data acquisition and computing challenges due to the immense size of the detectors, the data volumes that are generated through the continuous digitization of the frontend systems, and the need to buffer the full data stream to allow for highly asynchronous triggering and extraction of physics events. These challenges are compounded by the stringent timing and synchronization requirements that are placed on the acquisition systems by the need to precisely correlate information between the accelerator complex and the remote detector locations. The NOvA Data Acquisition system has been designed and built to meets these challenges. The system utilizes a highly modular, novel acquisition and event building scheme, which has been deployed on a large hierarch...

  10. Summary report for Group X6: Heat removal system and system analysis

    Energy Technology Data Exchange (ETDEWEB)

    Leung, W

    2005-12-15

    This report is a summary of the activities of the X6 design support for the Heat Removal System (HRS) of MEGAPIE. It can be divided into two main parts: The first part is about the design and manufacturing of he cooling loop (the first 3 chapters), and the second part is dealing with the thermal hydraulic analysis of the overall HRS. This also reflects the change of the X6 activities from design to operation support. The activities of this group are more or less driven by the needs rather than a complete set of tasks given at the start of the project. The first part chronicles the system development. Some of the arguments are probably outdated but are kept in the original form to illustrate the evolution of concepts. The main objective is, of course, to design a heat removal system that can cool the liquid metal spallation target for a 1 MW proton beam i.e. 1.74 mA in 575 MeV). It is also reckoned that the liquid metal, BE (lead-bismuth-eutectic), must be kept liquid even when the proton beam was switched off. This requires either that the cooling system can be shut down or the operating temperature of the coolant be higher than the freezing point of LBE. As for safety concerns, the HRS system must not exert a pressure that exceeds the design pressure of the target beam window in case of a break at the target heat exchanger (THX); this limits the cover gas pressure to about 4 bar(a). These are the basic design principles that carry through the conceptual and engineering design of he system. The organic coolant Diphyl THT was then chosen, because of its wide range of operating temperature (i.e. from 0 to 340 degC) and high boiling point, and a proven record in industrial applications. (author)

  11. Summary report for Group X6: Heat removal system and system analysis

    International Nuclear Information System (INIS)

    Leung, W.

    2005-12-01

    This report is a summary of the activities of the X6 design support for the Heat Removal System (HRS) of MEGAPIE. It can be divided into two main parts: The first part is about the design and manufacturing of he cooling loop (the first 3 chapters), and the second part is dealing with the thermal hydraulic analysis of the overall HRS. This also reflects the change of the X6 activities from design to operation support. The activities of this group are more or less driven by the needs rather than a complete set of tasks given at the start of the project. The first part chronicles the system development. Some of the arguments are probably outdated but are kept in the original form to illustrate the evolution of concepts. The main objective is, of course, to design a heat removal system that can cool the liquid metal spallation target for a 1 MW proton beam i.e. 1.74 mA in 575 MeV). It is also reckoned that the liquid metal, BE (lead-bismuth-eutectic), must be kept liquid even when the proton beam was switched off. This requires either that the cooling system can be shut down or the operating temperature of the coolant be higher than the freezing point of LBE. As for safety concerns, the HRS system must not exert a pressure that exceeds the design pressure of the target beam window in case of a break at the target heat exchanger (THX); this limits the cover gas pressure to about 4 bar(a). These are the basic design principles that carry through the conceptual and engineering design of he system. The organic coolant Diphyl THT was then chosen, because of its wide range of operating temperature (i.e. from 0 to 340 degC) and high boiling point, and a proven record in industrial applications. (author)

  12. Simplified analysis of passive residual heat removal systems for small size PWR's

    International Nuclear Information System (INIS)

    Botelho, D.A.

    1992-02-01

    The function and general objectives of a passive residual heat removal system for small size PWR's are defined. The characteristic configuration, the components and the operation modes of this system are concisely described. A preliminary conceptual specification of this system, for a small size PWR of 400 MW thermal, is made analogous to the decay heat removal system of the AP-600 reactor. It is shown by analytic models that such passive systems can dissipate 2% of nominal power within the thermal limits allowed to the reactor fuel elements. (author)

  13. Joint ultrasound baseline abnormalities predict a specific long-term clinical outcome in systemic lupus erythematosus patients.

    Science.gov (United States)

    Corzo, P; Salman-Monte, T C; Torrente-Segarra, V; Polino, L; Mojal, S; Carbonell-Abelló, J

    2017-06-01

    Objective To describe long-term clinical and serological outcome in all systemic lupus erythematosus (SLE) domains in SLE patients with hand arthralgia (HA) and joint ultrasound (JUS) inflammatory abnormalities, and to compare them with asymptomatic SLE patients with normal JUS. Methods SLE patients with HA who presented JUS inflammatory abnormalities ('cases') and SLE patients without HA who did not exhibit JUS abnormalities at baseline ('controls') were included. All SLE clinical and serological domain involvement data were collected. End follow-up clinical activity and damage scores (systemic lupus erythematosus disease activity index (SLEDAI), Systemic Lupus International Collaborating Clinics/American College of Rheumatology (SLICC/ACR)) were recorded. JUS inflammatory abnormalities were defined based on the Proceedings of the Seventh International Consensus Conference on Outcome Measures in Rheumatology Clinical Trials (OMERACT-7) definitions. Statistical analyses were carried out to compare 'cases' and 'controls'. Results A total of 35 patients were recruited. The 'cases', n = 18/35, had a higher incidence of musculoskeletal involvement (arthralgia and/or arthritis) through the follow-up period (38.9% vs 0%, p = 0.008) and received more hydroxychloroquine (61.1% vs 25.0%, p = 0.034) and methotrexate (27.8% vs 0%, p = 0.046) compared to 'controls', n = 17/35. Other comparisons did not reveal any statistical differences. Conclusions We found SLE patients with arthralgia who presented JUS inflammatory abnormalities received more hydroxychloroquine and methotrexate, mainly due to persistent musculoskeletal involvement over time. JUS appears to be a useful technique for predicting worse musculoskeletal outcome in SLE patients.

  14. MARBLE (Multiple Antenna Radio-interferometry for Baseline Length Evaluation): Development of a Compact VLBI System for Calibrating GNSS and Electronic Distance Measurement Devices

    Science.gov (United States)

    Ichikawa, R.; Ishii, A.; Takiguchi, H.; Kimura, M.; Sekido, M.; Takefuji, K.; Ujihara, H.; Hanado, Y.; Koyama, Y.; Kondo, T.; Kurihara, S.; Kokado, K.; Kawabata, R.; Nozawa, K.; Mukai, Y.; Kuroda, J.; Ishihara, M.; Matsuzaka, S.

    2012-12-01

    We are developing a compact VLBI system with a 1.6-m diameter aperture dish in order to provide reference baseline lengths for calibration. The reference baselines are used to validate surveying instruments such as GPS and EDM and is maintained by the Geospatial Information Authority of Japan (GSI). The compact VLBI system will be installed at both ends of the reference baseline. Since the system is not sensitive enough to detect fringes between the two small dishes, we have designed a new observation concept including one large dish station. We can detect two group delays between each compact VLBI system and the large dish station based on conventional VLBI measurement. A group delay between the two compact dishes can be indirectly calculated using a simple equation. We named the idea "Multiple Antenna Radio-interferometry for Baseline Length Evaluation", or MARBLE system. The compact VLBI system is easy transportable and consists of the compact dish, a new wide-band front-end system, azimuth and elevation drive units, an IF down-converter unit, an antenna control unit (ACU), a counterweight, and a monument pillar. Each drive unit is equipped with a zero-backlash harmonic drive gearing component. A monument pillar is designed to mount typical geodetic GNSS antennas easily and an offset between the GNSS antenna reference point. The location of the azimuth-elevation crossing point of the VLBI system is precisely determined with an uncertainty of less than 0.2 mm. We have carried out seven geodetic VLBI experiments on the Kashima-Tsukuba baseline (about 54 km) using the two prototypes of the compact VLBI system between December 2009 and December 2010. The average baseline length and repeatability of the experiments is 54184874.0 ± 2.4 mm. The results are well consistent with those obtained by GPS measurements. In addition, we are now planning to use the compact VLBI system for precise time and frequency comparison between separated locations.

  15. Conceptual system for removal of plutonium from soils and scrap

    International Nuclear Information System (INIS)

    Bruns, L.E.

    1982-01-01

    An integrated conceptual scheme for processing TRU wastes and sediments retrieved from a typical TRU-burial ground is presented. This scheme features (a) use of a High Gradient Magnetic System to separate a TRU (e.g., Pu and Am) fraction containing materials from inert soil particles, (b) leaching of the TRU fraction with HNO 3 -HF and (c) operation of a TOPO-CCl 4 reflux-type solvent extraction system to concentrate actinides into a very small volume of product solution

  16. Biological removal of algae in an integrated pond system

    CSIR Research Space (South Africa)

    Meiring, PGJ

    1995-01-01

    Full Text Available A system of oxidation ponds in series with a biological trickling filter is described. It was known that this arrangement was incapable of reducing effectively the levels of algae present in the pond liquid even though nitrification was effected...

  17. Removal of micro-organisms in a small-scale hydroponics wastewater treatment system.

    Science.gov (United States)

    Ottoson, J; Norström, A; Dalhammar, G

    2005-01-01

    To measure the microbial removal capacity of a small-scale hydroponics wastewater treatment plant. Paired samples were taken from untreated, partly-treated and treated wastewater and analysed for faecal microbial indicators, i.e. coliforms, Escherichia coli, enterococci, Clostridium perfringens spores and somatic coliphages, by culture based methods. Escherichia coli was never detected in effluent water after >5.8-log removal. Enterococci, coliforms, spores and coliphages were removed by 4.5, 4.1, 2.3 and 2.5 log respectively. Most of the removal (60-87%) took place in the latter part of the system because of settling, normal inactivation (retention time 12.7 d) and sand filtration. Time-dependent log-linear removal was shown for spores (k = -0.17 log d(-1), r(2) = 0.99). Hydroponics wastewater treatment removed micro-organisms satisfactorily. Investigations on the microbial removal capacity of hydroponics have only been performed for bacterial indicators. In this study it has been shown that virus and (oo)cyst process indicators were removed and that hydroponics can be an alternative to conventional wastewater treatment.

  18. Experiences with on line fault detection system for protection system logic and decay heat removal system logic in Dhruva

    International Nuclear Information System (INIS)

    Ramkumar, N.; Dutta, P.K.; Darbhe, M.D.; Bharadwaj, G.

    2001-01-01

    Dhruva is a 100 MW (Thermal) natural uranium fuelled, vertical core, tank type multi purpose research reactor with heavy water acting as moderator, coolant and reflector. Helium is used as cover gas for heavy water system. Reactor Protection System and Decay Heat Removal System (DHRS) have triplicated instrumented channels. The logic for these systems are hybrid in nature with a mixture of relay logic and solid state logic. Fine Impulse Technique(FIT) is employed for On-line fault detection in the solid state logics of these systems. The FIT systems were designed in the early eighties. Operating experiences over the past 15 years has revealed certain deficiencies. In view of this, a microcomputer based state of the art FIT systems for logics of Reactor Protection System and DHRS are being implemented with improved functionalities built into them. This paper describes the operating experience of old FIT systems and improved features of the proposed new FIT systems. (author)

  19. Debris removal system for a nuclear fuel assembly

    International Nuclear Information System (INIS)

    Cooper, F.W. Jr.; Dailey, G.F.

    1987-01-01

    A system is described for working on an elongated nuclear fuel assembly suspended vertically and submerged in a spent fuel pool having fuel assembly racks at the bottom. The system comprises a work platform disposable in the pool and adapted to be supported on the fuel assembly racks. The platform has an opening disposed in registry with a selected one of the underlying racks; guide means carried by the platform for guiding the suspended fuel assembly into the opening and the selected rack to accommodate vertical movement of the fuel assembly into and out of the rack to make different portions of the fuel assembly accessible from the platform; and tool manipulating apparatus disposable on the platform adjacent to the opening, the tool manipulating apparatus including a tool carriage. Tool holders for respectively holding associated tools. Each of the tool holders is mounted on the tool carriage for reciprocating movement with respect along a predetermined axis between extended and retracted conditions

  20. Filtration system for the removal of depleted uranium from water

    International Nuclear Information System (INIS)

    Barlett, P.T.; Wolfe, S.

    1989-01-01

    Previous depleted uranium (DU) munitions testing has resulted in 2 132 cubic meters (500 to 35,000 gallons) of wastewater containing: DU concentrations from 2.5 x 10 -5 to 9 x 10 -8 microcuries/mL DU particles equal to and greater than 0.1 micron in size. Personnel reasoned that if particles could be filtered from the wastewater down to a 0.1 micron size, the wastewater could be disposed of on-site and comply with the Nuclear Regulatory Commission (NRC) standard of 35 pCi/g of soil. This paper compares the effectiveness of three cross-flow membrane modules using a pilot-scale microfiltration (MF) system that was designed to process the wastewater described and designed to allow direct scale-up to a system that is capable of processing 132 m 3 (35,000 gals) of wastewater that can then be disposed of on-site within applicable standards. A cross-flow MF system was designed, assembled, and tested using replicated wastewater

  1. Fermilab satellite refrigerator compressors with the oil- and moisture-removal systems

    International Nuclear Information System (INIS)

    Satti, J.A.; Andrews, R.A.

    1983-08-01

    We have designed and tested a helium purification system for the Energy Doubler and the experimental areas. A purification system is installed after each screw compressor in the satellite refrigerators. The purification system removes oil mist, oil vapor, water vapor, and particulate from the compressed helium. The units were designed with consideration of modularity and necessary redundancy (i.e., guard purification). Test results which led to the final configuration are presented, along with achieved performance of the oil removal in the operating system

  2. Investigating the mechanism of clofibric acid removal in Fe(0)/H2O systems.

    Science.gov (United States)

    Ghauch, Antoine; Abou Assi, Hala; Tuqan, Almuthanna

    2010-04-15

    Since the introduction of iron wall technology, the inherent relationship between contaminant removal and iron corrosion has been mostly attributed to electron transfer from the metal body (direct reduction). This thermodynamically founded premise has failed to explain several experimental facts. Recently, a new concept considering adsorption and co-precipitation as fundamental contaminant removal mechanisms was introduced. This consistent concept has faced very skeptic views and necessarily needs experimental validation. The present work was the first independent attempt to validate the new concept using clofibric acid (CLO) as model compound. For this purpose, a powdered Fe(0) material (Fe(0)) was used in CLO removal experiments under various experimental conditions. Additional experiments were performed with plated Fe(0) (mFe(0): Fe(0)/Pd(0), Fe(0)/Ni(0)) to support the discussion of removal mechanism. Main investigated experimental variables included: abundance of O(2), abundance of iron corrosion products (ICPs) and shaking operations. Results corroborated the concept that quantitative contaminant removal in Fe(0)/H(2)O systems occurs within the oxide-film in the vicinity of Fe(0). Additionally, mixing type and shaking intensity significantly influenced the extent of CLO removal. More importantly, HPLC/MS revealed that the identity of reaction products depends on the extent of iron corrosion or the abundance of ICPs. The investigation of the CLO/Fe(0)/H(2)O system disproved the popular view that direct reduction mediates contaminant removal in the presence of Fe(0). 2009 Elsevier B.V. All rights reserved.

  3. Investigating the mechanism of clofibric acid removal in Fe0/H2O systems

    International Nuclear Information System (INIS)

    Ghauch, Antoine; Abou Assi, Hala; Tuqan, Almuthanna

    2010-01-01

    Since the introduction of iron wall technology, the inherent relationship between contaminant removal and iron corrosion has been mostly attributed to electron transfer from the metal body (direct reduction). This thermodynamically founded premise has failed to explain several experimental facts. Recently, a new concept considering adsorption and co-precipitation as fundamental contaminant removal mechanisms was introduced. This consistent concept has faced very skeptic views and necessarily needs experimental validation. The present work was the first independent attempt to validate the new concept using clofibric acid (CLO) as model compound. For this purpose, a powdered Fe 0 material (Fe 0 ) was used in CLO removal experiments under various experimental conditions. Additional experiments were performed with plated Fe 0 (mFe 0 : Fe 0 /Pd 0 , Fe 0 /Ni 0 ) to support the discussion of removal mechanism. Main investigated experimental variables included: abundance of O 2 , abundance of iron corrosion products (ICPs) and shaking operations. Results corroborated the concept that quantitative contaminant removal in Fe 0 /H 2 O systems occurs within the oxide-film in the vicinity of Fe 0 . Additionally, mixing type and shaking intensity significantly influenced the extent of CLO removal. More importantly, HPLC/MS revealed that the identity of reaction products depends on the extent of iron corrosion or the abundance of ICPs. The investigation of the CLO/Fe 0 /H 2 O system disproved the popular view that direct reduction mediates contaminant removal in the presence of Fe 0 .

  4. Design and analysis of a new passive residual heat removal system

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Xing [Key Subject Laboratory of Nuclear Safety and Simulation Technology, Harbin Engineering University, Harbin, Heilongjiang 150001 (China); Peng, Minjun, E-mail: heupmj@163.com [Key Subject Laboratory of Nuclear Safety and Simulation Technology, Harbin Engineering University, Harbin, Heilongjiang 150001 (China); Yuan, Xiao [Guangxi Fangchenggang Nuclear Power Co., Ltd (China); Xia, Genglei [Key Subject Laboratory of Nuclear Safety and Simulation Technology, Harbin Engineering University, Harbin, Heilongjiang 150001 (China)

    2016-07-15

    Highlights: • An air cooling passive residual heat removal System (PRHRs) is designed. • Using RELAP5/MOD3.4 code to analyze the operation characteristics of the PRHRs. • Noncondensable gas is used to simulate the hydrodynamic behavior in the air cooling tower. • The natural circulations could respectively establish in the primary circuit and the PRHRs circuit. • The PRHRs could remove the residual heat effectively. - Abstract: The inherent safety functions will mitigate the consequences of the accidents, and it can be accomplished through the passive safety systems which employed in the typical pressurized water reactor (PWR). In this paper, a new passive residual heat removal system (PRHRS) is designed for a typical nuclear power plant. PRHRS consists of a steam generator (SG), a cooling tank with two groups of cooling pipes, an air-cooling heat exchanger (AHX), an air-cooling tower, corresponding pipes and valves. The cooling tank which works as an intermediate buffer device is used to transfer the core decay heat to the AHX, and then the core decay heat will be removed to the atmosphere finally. The RELAP5/MOD3.4 code is used to analyze the operation characteristics of PRHRS and the primary loop system. It shows PRHRS could remove the decay heat from the primary loop effectively, and the natural circulations can be established in the primary circuit and the PRHRS circuit respectively. Furthermore, the sensitivity study has also been done to research the effect of various factors on the heat removal capacity.

  5. The effect of four different irrigation systems in the removal of a root canal sealer.

    Science.gov (United States)

    Grischke, J; Müller-Heine, A; Hülsmann, M

    2014-09-01

    The aim of this study was to compare the efficiency of sonic, ultrasonic, and hydrodynamic devices in the removal of a root canal sealer from the surface and from simulated irregularities of root canals. Fifty-three root canals with two standardized grooves in the apical and coronal parts of longitudinally split roots were covered with AH Plus root canal sealer. Compared were the effects of (control) syringe irrigation, (1) CanalBrush, (2) passive ultrasonic irrigation, (3) EndoActivator, and (4) RinsEndo on the removal of the sealer. The specimens were divided into four groups (N = 12) and one control group (N = 5) via randomization. The amount of remaining sealer in the root canal irregularities was evaluated under a microscope using a 4-grade scoring system, whereas the remaining sealer on the root canal surface was evaluated with a 7-grade scoring system. Passive ultrasonic irrigation is more effective than the other tested irrigation systems or syringe irrigation in removing sealer from root canal walls (p irrigation shows a superior effect on sealer removal from the root canal surface during endodontic retreatment. Cleaning of lateral grooves seems not to be possible with one of the techniques investigated. Incomplete removal of root canal sealer during re-treatment may cause treatment failure. Passive Ultrasonic irrigation seems to be the most effective system to remove sealer from a root canal.

  6. Biofilms and Oxidizing Biocides; Evaluation of Disinfection and Removal Effects by Using Established Microbial Systems.

    Science.gov (United States)

    Tachikawa, Mariko

    2017-01-01

    The formation of bacterial biofilms and their disinfection and removal have been important subjects in the maintenance of water quality in areas such as public spas, swimming pools, food processing lines, industrial water systems, and in the hygienic control of medical devices, hospital procedures, etc. Presented here is an outline of biofilm formation, as well as studies on the disinfection and removal of biofilms by oxidizing biocides using established biofilms. These studies using established biofilms may increase the understanding of the variable response of biofilms to planktonic bacteria, and the unique aspects of oxidizing biocides in the disinfection and removal of biofilms.

  7. Study of efficiency of particles removal by different filtration systems in a municipal wastewater tertiary treatment

    International Nuclear Information System (INIS)

    Andreu, P. S.; Lardin Mifsut, C.; Farinas Iglesias, M.; Sanchez-Arevalo Serrano, J.; Perez Sanchez, P.; Rancano Perez, A.

    2009-01-01

    The disinfection of municipal wastewater using ultraviolet radiation depends greatly on the presence within the water of particles in suspension. This work determines how the level of elimination of particles varies depending on the technique of filtration used (open, closed sand filters, with continuous washing of the sand, cloth, disk and ring filters). all systems are very effective in the removal of particles more than 25 microns and for removing helminth eggs. The membrane bio-reactors with ultrafiltration membranes were superior in terms of particle removal when compared to conventional filters. (Author) 11 refs.

  8. Removal of an acid fume system contaminated with perchlorates located within hot cell

    International Nuclear Information System (INIS)

    Rosenberg, K.E.; Henslee, S.P.; Vroman, W.R.; Krsul, J.R.; Michelbacher, J.A.; Knighton, G.C.

    1992-09-01

    An add scrubbing system located within the confines of a highly radioactive hot cell at Argonne National Laboratory-West (ANL-W) was remotely removed. The acid scrubbing system was routinely used for the dissolution of irradiated reactor fuel samples and structural materials. Perchloric acid was one of the acids used in the dissolution process and remained in the system with its inherent risks. Personnel could not enter the hot cell to perform the dismantling of the acid scabbing system due to the high radiation field and the explosion potential associated with the perchlorates. A robot was designed and built at ANL-W and used to dismantle the system without the need for personnel entry into the hot cell. The robot was also used for size reduction of removed components and loading of the removed components into waste containers

  9. Comparative efficiency of final endodontic cleansing procedures in removing a radioactive albumin from root canal systems

    International Nuclear Information System (INIS)

    Cecic, P.A.; Peters, D.D.; Grower, M.F.

    1984-01-01

    Fifty-six teeth were initially instrumented, with the use of seven irrigants or irrigant combinations, and filled with radioactive albumin. The study then showed the relative ability of three final endodontic procedures (copious reirrigation with saline solution, drying with paper points, and reassuring patency of the canal with the final instrument) to remove the albumin. Even after copious irrigation, each additional procedure removed statistically significant amounts of albumin. Alternating an organic solvent and an inorganic solvent did appear to leave the canal system in the optimal condition for final cleansing procedures. The study then correlated the relative efficiency of irrigation alone versus instrumentation plus irrigation in removing the remaining albumin from the canal systems. Reinstrumentation plus copious irrigation removed significantly more albumin than copious irrigation alone

  10. Nitrogen removal and nitrate leaching for two perennial, sod-based forage systems receiving dairy effluent.

    Science.gov (United States)

    Woodard, Kenneth R; French, Edwin C; Sweat, Lewin A; Graetz, Donald A; Sollenberger, Lynn E; Macoon, Bisoondat; Portier, Kenneth M; Rymph, Stuart J; Wade, Brett L; Prine, Gordon M; Van Horn, Harold H

    2003-01-01

    In northern Florida, year-round forage systems are used in dairy effluent sprayfields to reduce nitrate leaching. Our purpose was to quantify forage N removal and monitor nitrate N (NO3(-)-N) concentration below the rooting zone for two perennial, sod-based, triple-cropping systems over four 12-mo cycles (1996-2000). The soil is an excessively drained Kershaw sand (thermic, uncoated Typic Quartzip-samment). Effluent N rates were 500, 690, and 910 kg ha(-1) per cycle. Differences in N removal between a corn (Zea mays L.)-bermudagrass (Cynodon spp.)-rye (Secale cereale L.) system (CBR) and corn-perennial peanut (Arachis glabrata Benth.)-rye system (CPR) were primarily related to the performance of the perennial forages. Nitrogen removal of corn (125-170 kg ha(-1)) and rye (62-90 kg ha(-1)) was relatively stable between systems and among cycles. The greatest N removal was measured for CBR in the first cycle (408 kg ha(-1)), with the bermudagrass removing an average of 191 kg N ha(-1). In later cycles, N removal for bermudagrass declined because dry matter (DM) yield declined. Yield and N removal of perennial peanut increased over the four cycles. Nitrate N concentrations below the rooting zone were lower for CBR than CPR in the first two cycles, but differences were inconsistent in the latter two. The CBR system maintained low NO3(-)-N leaching in the first cycle when the bermudagrass was the most productive; however, it was not a sustainable system for long-term prevention of NO3(-)-N leaching due to declining bermudagrass yield in subsequent cycles. For CPR, effluent N rates > or = 500 kg ha(-1) yr(-1) have the potential to negatively affect ground water quality.

  11. Impulse noise estimation and removal for OFDM systems

    KAUST Repository

    Al-Naffouri, Tareq Y.

    2014-03-01

    Orthogonal Frequency Division Multiplexing (OFDM) is a modulation scheme that is widely used in wired and wireless communication systems. While OFDM is ideally suited to deal with frequency selective channels and AWGN, its performance may be dramatically impacted by the presence of impulse noise. In fact, very strong noise impulses in the time domain might result in the erasure of whole OFDM blocks of symbols at the receiver. Impulse noise can be mitigated by considering it as a sparse signal in time, and using recently developed algorithms for sparse signal reconstruction. We propose an algorithm that utilizes the guard band subcarriers for the impulse noise estimation and cancellation. Instead of relying on ℓ1 minimization as done in some popular general-purpose compressive sensing schemes, the proposed method jointly exploits the specific structure of this problem and the available a priori information for sparse signal recovery. The computational complexity of the proposed algorithm is very competitive with respect to sparse signal reconstruction schemes based on ℓ1 minimization. The proposed method is compared with respect to other state-of-the-art methods in terms of achievable rates for an OFDM system with impulse noise and AWGN. © 2014 IEEE.

  12. Impulse noise estimation and removal for OFDM systems

    KAUST Repository

    Al-Naffouri, Tareq Y.; Quadeer, Ahmed Abdul; Caire, Giuseppe

    2014-01-01

    Orthogonal Frequency Division Multiplexing (OFDM) is a modulation scheme that is widely used in wired and wireless communication systems. While OFDM is ideally suited to deal with frequency selective channels and AWGN, its performance may be dramatically impacted by the presence of impulse noise. In fact, very strong noise impulses in the time domain might result in the erasure of whole OFDM blocks of symbols at the receiver. Impulse noise can be mitigated by considering it as a sparse signal in time, and using recently developed algorithms for sparse signal reconstruction. We propose an algorithm that utilizes the guard band subcarriers for the impulse noise estimation and cancellation. Instead of relying on ℓ1 minimization as done in some popular general-purpose compressive sensing schemes, the proposed method jointly exploits the specific structure of this problem and the available a priori information for sparse signal recovery. The computational complexity of the proposed algorithm is very competitive with respect to sparse signal reconstruction schemes based on ℓ1 minimization. The proposed method is compared with respect to other state-of-the-art methods in terms of achievable rates for an OFDM system with impulse noise and AWGN. © 2014 IEEE.

  13. Removal of contaminated asphalt layers by using heat generating powder metallic systems

    International Nuclear Information System (INIS)

    Barinov, A.S.; Karlina, O.K.; Ojovan, M.I.

    1996-01-01

    Heat generating systems on the base of powder metallic fuel were used for the removal of contaminated asphalt layers. Decontamination of spots which had complex geometric form was performed. Asphalt layers with deep contamination were removed essentially all radionuclides being retained in asphalt residue. Only a small part (1 - 2 %) of radionuclides could pass to combustion slag. No radionuclides were detected in aerosol-gas phase during decontamination process

  14. Nuclear reactor cavity floor passive heat removal system

    Science.gov (United States)

    Edwards, Tyler A.; Neeley, Gary W.; Inman, James B.

    2018-03-06

    A nuclear reactor includes a reactor core disposed in a reactor pressure vessel. A radiological containment contains the nuclear reactor and includes a concrete floor located underneath the nuclear reactor. An ex vessel corium retention system includes flow channels embedded in the concrete floor located underneath the nuclear reactor, an inlet in fluid communication with first ends of the flow channels, and an outlet in fluid communication with second ends of the flow channels. In some embodiments the inlet is in fluid communication with the interior of the radiological containment at a first elevation and the outlet is in fluid communication with the interior of the radiological containment at a second elevation higher than the first elevation. The radiological containment may include a reactor cavity containing a lower portion of the pressure vessel, wherein the concrete floor located underneath the nuclear reactor is the reactor cavity floor.

  15. Removal performance of toluene, p-xylene and ethylene using a plasma-pretreated biotrickling system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H.J.; Han, B.; Kim, S.J.; Kim, Y.J. [Korea Inst. of Machinery and Materials (Korea, Republic of)

    2010-07-01

    The use of biological systems for removing volatile organic compounds (VOCs) from gaseous emissions was discussed. The systems rely on microorganism activity and do not produce any secondary pollution. Recently, the integration of biofiltration and UV photooxidation has been performed to remove VOCs in air. The systems using both UV photooxidation and biofiltration removed recalcitrant and VOCs more effectively than a stand-alone process using only biofiltration, because the UV pre-treatment not only removes the gases, but also changes them to easily biodegradable and water soluble byproducts such as acids and aldehydes. The biotrickling filter in this study was exposed to toluene gas only for over one month to cultivate specific microorganisms. The non-thermal plasma was a dielectric barrier discharge (DBD) plasma. The performance for removing toluene, p-xylene, and ethylene by the biotrickling filter, the plasma reactor and the plasma-pretreated bio-trickling system was investigated at a variety of flow rates and inlet concentrations of the test gases. The experimental results showed that the removal efficiencies of the integrated system of non-thermal plasma and biotrickling filter for p-xylene and ethylene were enhanced by 28.0 and 29.7 percent respectively, and increased by only 5.3 percent for toluene, as compared to those of the stand-alone biotrickling filtration. It was concluded that the plasma-pretreated biofiltration system could enhance the performance of the biotrickling filter for removing VOC gases, particularly for reducing low biodegradable pollutants with high loading which are chemically different from the cultivated gases. 12 refs., 7 figs.

  16. Alternate particle removal technologies for the Airborne Activity Confinement System at the Savannah River Site

    International Nuclear Information System (INIS)

    Brockmann, J.E.; Adkins, C.L.J.; Gelbard, F.

    1991-09-01

    This report presents a review of the filtration technologies available for the removal of particulate material from a gas stream. It was undertaken to identify alternate filtration technologies that may be employed in the Airborne Activity Confinement System (AACS) at the Savannah River Plant. This report is organized into six sections: (1) a discussion of the aerosol source term and its definition, (2) a short discussion of particle and gaseous contaminant removal mechanisms, (3) a brief overview of particle removal technologies, (4) a discussion of the existing AACS and its potential shortcomings, (5) an enumeration of issues to be addressed in upgrading the AACS, and, (6) a detailed discussion of the identified technologies. The purpose of this report is to identity available options to the existing particle removal system. This system is in continuous operation during routine operation of the reactor. As will be seen, there are a number of options and the selection of any technology or combination of technologies will depend on the design aerosol source term (yet to be appropriately defined) as well as the flow requirements and configuration. This report does not select a specific technology. It focuses on particulate removal and qualitatively on the removal of radio-iodine and mist elimination. Candidate technologies have been selected from industrial and nuclear gas cleaning applications

  17. A coupled system of half-nitritation and ANAMMOX for mature landfill leachate nitrogen removal.

    Science.gov (United States)

    Li, Yun; Li, Jun; Zhao, Baihang; Wang, Xiujie; Zhang, Yanzhuo; Wei, Jia; Bian, Wei

    2017-09-01

    A coupled system of membrane bioreactor-nitritation (MBR-nitritation) and up-flow anaerobic sludge blanket-anaerobic ammonium oxidation (UASB-ANAMMOX) was employed to treat mature landfill leachate containing high ammonia nitrogen and low C/N. MBR-nitritation was successfully realized for undiluted mature landfill leachate with initial concentrations of 900-1500 mg/L [Formula: see text] and 2000-4000 mg/L chemical oxygen demand. The effluent [Formula: see text] concentration and the [Formula: see text] accumulation efficiency were 889 mg/L and 97% at 125 d, respectively. Half-nitritation was quickly realized by adjustment of hydraulic retention time and dissolved oxygen (DO), and a low DO control strategy could allow long-term stable operation. The UASB-ANAMMOX system showed high effective nitrogen removal at a low concentration of mature landfill leachate. The nitrogen removal efficiency was inhibited at excessive influent substrate concentration and the nitrogen removal efficiency of the system decreased as the concentration of mature landfill leachate increased. The MBR-nitritation and UASB-ANAMMOX processes were coupled for mature landfill leachate treatment and together resulted in high effective nitrogen removal. The effluent average total nitrogen concentration and removal efficiency values were 176 mg/L and 83%, respectively. However, the average nitrogen removal load decreased from 2.16 to 0.77 g/(L d) at higher concentrations of mature landfill leachate.

  18. Application of two-stage biofilter system for the removal of odorous compounds.

    Science.gov (United States)

    Jeong, Gwi-Taek; Park, Don-Hee; Lee, Gwang-Yeon; Cha, Jin-Myeong

    2006-01-01

    Biofiltration is a biological process which is considered to be one of the more successful examples of biotechnological applications to environmental engineering, and is most commonly used in the removal of odoriferous compounds. In this study, we have attempted to assess the efficiency with which both single and complex odoriferous compounds could be removed, using one- or two-stage biofiltration systems. The tested single odor gases, limonene, alpha-pinene, and iso-butyl alcohol, were separately evaluated in the biofilters. Both limonene and alpha-pinene were removed by 90% or more EC (elimination capacity), 364 g/m3/h and 321 g/m3/h, respectively, at an input concentration of 50 ppm and a retention time of 30 s. The iso-butyl alcohol was maintained with an effective removal yield of more than 90% (EC 375 g/m3/h) at an input concentration of 100 ppm. The complex gas removal scheme was applied with a 200 ppm inlet concentration of ethanol, 70 ppm of acetaldehyde, and 70 ppm of toluene with residence time of 45 s in a one- or two-stage biofiltration system. The removal yield of toluene was determined to be lower than that of the other gases in the one-stage biofilter. Otherwise, the complex gases were sufficiently eliminated by the two-stage biofiltration system.

  19. A new chemical system solution for acid gas removal

    Energy Technology Data Exchange (ETDEWEB)

    Seiler, M.; Rolker, J.; Witthaut, D.; Schulze, S. [Evonik Industries AG, Hanau (Germany); Buchholz, S. [Evonik Industries AG, Marl (Germany)

    2012-07-01

    An energy-efficient absorbent formulation fors eparating acid gases (e.g. CO{sub 2}, H2S) from gas streams such as natural gas, syngas or flue gas is important for a number of industrial applications. In many cases, a substantial share of their costs is driven by the operational expenditure (OPEX) of the CO{sub 2} separation unit. One possible strategy for reducing OPEX is the improvement of the absorbent performance. Although a number of absorbents for the separation of CO{sub 2} from gas streams exist, there is still a need to develop CO{sub 2} absorbents with an improved absorption performance, less corrosion and foaming, no nitrosamine formation, lower energy requirement and therefore less OPEX. This contribution aims at giving a brief state-of-the-art overview followed by an introduction and performance characterization of a new family of amine-based CO{sub 2} absorbents. High cyclic capacities in the range of 2.9 to 3.2 mol CO{sub 2} kg{sup -1} absorbent and low absorption enthalpies of about -30 kJ mol{sup -1} allow for significant savings in the regeneration energy of the new absorbent system. Calculations with the modified Kremser model indicate a reduction in the specific reboiler heat duty of 45 %. Moreover, the high-performance absorbents developed show much lower corrosion rates than state-of-the-art solutions that are currently employed. (orig.)

  20. Removing radio-active wastes from nuclear power stations by the STEAG system

    International Nuclear Information System (INIS)

    Baatz, H.

    1978-01-01

    The mobile STEAG System for conditioning radio-active wastes from nuclear power stations represents a particularly safe and economic method of removing them in present day conditions. Cementation by the FAFNIR System is used for the greater part of the waste, the liquid concentrate (evaporator concentrate and filter slurry). For the special case of the medium active resin balls from the primary circuits, embedding in plastic by the FAMA process has proved to be the only available successful process so far. The highly active solid waste from the reactor core is decomposed by the MOSAIK System, is packed in transportable and storable containers and is removed from the fuel element storage pond. The systems are so safe that faults or interruptions of power station operation due to faults in removing radio-active wastes can be excluded. (orig.) [de

  1. Construction of an integrated enzyme system consisting azoreductase and glucose 1-dehydrogenase for dye removal.

    Science.gov (United States)

    Yang, Yuyi; Wei, Buqing; Zhao, Yuhua; Wang, Jun

    2013-02-01

    Azo dyes are toxic and carcinogenic and are often present in industrial effluents. In this research, azoreductase and glucose 1-dehydrogenase were coupled for both continuous generation of the cofactor NADH and azo dye removal. The results show that 85% maximum relative activity of azoreductase in an integrated enzyme system was obtained at the conditions: 1U azoreductase:10U glucose 1-dehydrogenase, 250mM glucose, 1.0mM NAD(+) and 150μM methyl red. Sensitivity analysis of the factors in the enzyme system affecting dye removal examined by an artificial neural network model shows that the relative importance of enzyme ratio between azoreductase and glucose 1-dehydrogenase was 22%, followed by dye concentration (27%), NAD(+) concentration (23%) and glucose concentration (22%), indicating none of the variables could be ignored in the enzyme system. Batch results show that the enzyme system has application potential for dye removal. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Apparatus and method for removing solvent from carbon dioxide in resin recycling system

    Science.gov (United States)

    Bohnert, George W [Harrisonville, MO; Hand, Thomas E [Lee's Summit, MO; DeLaurentiis, Gary M [Jamestown, CA

    2009-01-06

    A two-step resin recycling system and method solvent that produces essentially contaminant-free synthetic resin material. The system and method includes one or more solvent wash vessels to expose resin particles to a solvent, the solvent contacting the resin particles in the one or more solvent wash vessels to substantially remove contaminants on the resin particles. A separator is provided to separate the solvent from the resin particles after removal from the one or more solvent wash vessels. The resin particles are next exposed to carbon dioxide in a closed loop carbon dioxide system. The closed loop system includes a carbon dioxide vessel where the carbon dioxide is exposed to the resin, substantially removing any residual solvent remaining on the resin particles after separation. A separation vessel is also provided to separate the solvent from the solvent laden carbon dioxide. Both the carbon dioxide and the solvent are reused after separation in the separation vessel.

  3. Removal of Escherichia coli via low frequency electromagnetic field in riverbank filtration system.

    Science.gov (United States)

    Selamat, Rossitah; Abustan, Ismail; Rizal Arshad, Mohd; Mokhtar Kamal, Nurul Hana

    2018-04-01

    The removal of Escherichia coli (E. coli) via low frequency of electromagnetic field (LF-EMF) with different magnetic field was studied. LF-EMF is known as a high magnetic susceptibility method, which could affect E. coli growth without the usage of chemicals. The aim of this study was to investigate the removal of E. coli by using LF-EMF in water abstraction for the riverbank filtration (RBF) application. The effect of LF-EMF with the intensity of 2 to 10mT and 50Hz on coiled column of 1mm copper wire at 1 to 6 hours was assessed. The removal of E. coli after exposing to LF-EMF on the column model was measured using most probable number (MPN/100mL) and colonies forming unit (CFU/100mL) methods. Water flows into the column were varied up to 6 hours and with flowrate of 100 mL/min. Experimental results demonstrate that 100% of E. coli was removed at 8mT after 6 hours exposure. The magnetic field at 10mT removed 100% of E. coli after 4 hours exposure. The results obtained in this study proved that the LF-EMF was efficient in E. coli removal from RBF system. These finding indicated that the LF-EMF intensities and time of exposure can affect the removal of E. coli.

  4. Nitrogen and phosphorus removed from a subsurface flow multi-stage filtration system purifying agricultural runoff.

    Science.gov (United States)

    Zhao, Yaqi; Huang, Lei; Chen, Yucheng

    2018-07-01

    Agricultural nonpoint source pollution has been increasingly serious in China since the 1990s. The main causes were excessive inputs of nitrogen fertilizer and pesticides. A multi-stage filtration system was built to test the purification efficiencies and removal characteristics of nitrogen and phosphorus when treating agricultural runoff. Simulated runoff pollution was prepared by using river water as source water based on the monitoring of local agricultural runoff. Experimental study had been performed from September to November 2013, adopting 12 h for flooding and 12 h for drying. The results showed that the system was made adaptive to variation of inflow quality and quantity, and had good removal for dissolved total nitrogen, total nitrogen, dissolved total phosphorus (DTP), and total phosphorus, and the average removal rate was 27%, 36%, 32%, and 48%, respectively. Except nitrate ([Formula: see text]), other forms of nitrogen and phosphorus all decreased with the increase of stages. Nitrogen was removed mainly in particle form the first stage, and mostly removed in dissolved form the second and third stage. Phosphorus was removed mainly in particulate during the first two stages, but the removal of particulate phosphorus and DTP were almost the same in the last stage. An approximate logarithmic relationship between removal loading and influent loading to nitrogen and phosphorus was noted in the experimental system, and the correlation coefficient was 0.78-0.94. [Formula: see text]: ammonium; [Formula: see text]: nitrite; [Formula: see text]: nitrate; DTN: dissolved total nitrogen; TN: total nitrogen; DTP: dissolved total phosphorus; TP: total phosphorus; PN: particulate nitrogen; PP: particulate phosphorus.

  5. Mathematical modeling based evaluation and simulation of boron removal in bioelectrochemical systems.

    Science.gov (United States)

    Ping, Qingyun; Abu-Reesh, Ibrahim M; He, Zhen

    2016-11-01

    Boron removal is an arising issue in desalination plants due to boron's toxicity. As an emerging treatment concept, bioelectrochemical systems (BES) can achieve potentially cost-effective boron removal by taking advantage of cathodic-produced alkali. Prior studies have demonstrated successful removal of boron in microbial desalination cells (MDCs) and microbial fuel cells (MFCs), both of which are representative BES. Herein, mathematical models were developed to further evaluate boron removal by different BES and understand the key operating factors. The models delivered very good prediction of the boron concentration in the MDC integrated with Donnan Dialysis (DD) system with the lowest relative root-mean-square error (RMSE) of 0.00%; the predication of the MFC performance generated the highest RMSE of 18.55%. The model results of salt concentration, solution pH, and current generation were well fitted with experimental data for RMSE values mostly below 10%. The long term simulation of the MDC-DD system suggests that the accumulation of salt in the catholyte/stripping solution could have a positive impact on the removal of boron due to osmosis-driven convection. The current generation in the MDC may have little influence on the boron removal, while in the MFC the current-driven electromigration can contribute up to 40% of boron removal. Osmosis-induced convection transport of boron could be the major driving force for boron removal to a low level 22.2 in order to avoid boron accumulation in the anolyte effluent. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Nuclear reactor with makeup water assist from residual heat removal system

    Science.gov (United States)

    Corletti, M.M.; Schulz, T.L.

    1993-12-07

    A pressurized water nuclear reactor uses its residual heat removal system to make up water in the reactor coolant circuit from an in-containment refueling water supply during staged depressurization leading up to passive emergency cooling by gravity feed from the refueling water storage tank, and flooding of the containment building. When depressurization commences due to inadvertence or a manageable leak, the residual heat removal system is activated manually and prevents flooding of the containment when such action is not necessary. Operation of the passive cooling system is not impaired. A high pressure makeup water storage tank is coupled to the reactor coolant circuit, holding makeup coolant at the operational pressure of the reactor. The staged depressurization system vents the coolant circuit to the containment, thus reducing the supply of makeup coolant. The level of makeup coolant can be sensed to trigger opening of successive depressurization conduits. The residual heat removal pumps move water from the refueling water storage tank into the coolant circuit as the coolant circuit is depressurized, preventing reaching the final depressurization stage unless the makeup coolant level continues to drop. The residual heat removal system can also be coupled in a loop with the refueling water supply tank, for an auxiliary heat removal path. 2 figures.

  7. Nuclear reactor with makeup water assist from residual heat removal system

    Science.gov (United States)

    Corletti, Michael M.; Schulz, Terry L.

    1993-01-01

    A pressurized water nuclear reactor uses its residual heat removal system to make up water in the reactor coolant circuit from an in-containment refueling water supply during staged depressurization leading up to passive emergency cooling by gravity feed from the refueling water storage tank, and flooding of the containment building. When depressurization commences due to inadvertence or a manageable leak, the residual heat removal system is activated manually and prevents flooding of the containment when such action is not necessary. Operation of the passive cooling system is not impaired. A high pressure makeup water storage tank is coupled to the reactor coolant circuit, holding makeup coolant at the operational pressure of the reactor. The staged depressurization system vents the coolant circuit to the containment, thus reducing the supply of makeup coolant. The level of makeup coolant can be sensed to trigger opening of successive depressurization conduits. The residual heat removal pumps move water from the refueling water storage tank into the coolant circuit as the coolant circuit is depressurized, preventing reaching the final depressurization stage unless the makeup coolant level continues to drop. The residual heat removal system can also be coupled in a loop with the refueling water supply tank, for an auxiliary heat removal path.

  8. Nuclear reactor with makeup water assist from residual heat removal system

    International Nuclear Information System (INIS)

    Corletti, M.M.; Schulz, T.L.

    1993-01-01

    A pressurized water nuclear reactor uses its residual heat removal system to make up water in the reactor coolant circuit from an in-containment refueling water supply during staged depressurization leading up to passive emergency cooling by gravity feed from the refueling water storage tank, and flooding of the containment building. When depressurization commences due to inadvertence or a manageable leak, the residual heat removal system is activated manually and prevents flooding of the containment when such action is not necessary. Operation of the passive cooling system is not impaired. A high pressure makeup water storage tank is coupled to the reactor coolant circuit, holding makeup coolant at the operational pressure of the reactor. The staged depressurization system vents the coolant circuit to the containment, thus reducing the supply of makeup coolant. The level of makeup coolant can be sensed to trigger opening of successive depressurization conduits. The residual heat removal pumps move water from the refueling water storage tank into the coolant circuit as the coolant circuit is depressurized, preventing reaching the final depressurization stage unless the makeup coolant level continues to drop. The residual heat removal system can also be coupled in a loop with the refueling water supply tank, for an auxiliary heat removal path. 2 figures

  9. A passive decay heat removal system for LWRs based on air cooling

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, Hiroyasu, E-mail: mochizki@u-fukui.ac.jp [Research Institute of Nuclear Engineering, University of Fukui, 1-2-4 Kanawa-cho, Tsuruga, Fukui 914-0055 (Japan); Yano, Takahiro [Graduate School of Engineering, University of Fukui, 1-2-4 Kanawa-cho, Tsuruga, Fukui 914-0055 (Japan)

    2015-05-15

    Highlights: • A passive decay heat removal system for LWRs is discussed. • An air cooler model which condenses steam is developed. • The decay heat can be removed by air coolers with forced convection. • The dimensions of the air cooler are proposed. - Abstract: The present paper describes the capability of an air cooling system (ACS) to remove decay heat from a core of LWR such as an advanced boiling water reactor (ABWR) and a pressurized water reactor (PWR). The motivation of the present research is the Fukushima severe accident (SA) on 11 March 2011. Since emergency cooling systems using electricity were not available due to station blackout (SBO) and malfunctions, many engineers might understand that water cooling was not completely reliable. Therefore, a passive decay heat removal (DHR) system would be proposed in order to prevent such an SA under the conditions of an SBO event. The plant behaviors during the SBO are calculated using the system code NETFLOW++ for the ABWR and PWR with the ACS. Two types of air coolers (ACs) are applied for the ABWR, i.e., a steam condensing air cooler (SCAC) of which intake for heat transfer tubes is provided in the steam region, and single-phase type of which intake is provided in the water region. The DHR characteristics are calculated under the conditions of the forced air circulation and also the natural air convection. As a result of the calculations, the decay heat can be removed safely by the reasonably sized ACS when heat transfer tubes are cooled with the forced air circulation. The heat removal rate per one finned heat transfer tube is evaluated as a function of air flow rate. The heat removal rate increases as a function of the air flow rate.

  10. Development of Carbon Dioxide Removal Systems for Advanced Exploration Systems 2014-2015

    Science.gov (United States)

    Knox, James C.; Coker, Robert; Huff, Timothy L.; Gatens, Robyn; Miller, Lee A.; Stanley, Christine

    2015-01-01

    A long-term goal for NASA is to enable crewed missions to Mars: first to the vicinity of Mars, and then to the Mars surface. These missions present new challenges for all aspects of spacecraft design in comparison with the International Space Station, as resupply is unavailable in the transit phase, and early return is not possible. Additionally, mass, power, and volume must be minimized for all phases to reduce propulsion needs. Mass reduction is particularly crucial for Mars surface landing and liftoff due to the challenges inherent in these operations for even much smaller payloads. In this paper we describe current and planned developments in the area of carbon dioxide removal to support future crewed Mars missions. Activities are also described that apply to both the resolution of anomalies observed in the ISS CDRA and the design of life support systems for future missions.

  11. Development of Carbon Dioxide Removal Systems for Advanced Exploration Systems 2015-2016

    Science.gov (United States)

    Knox, James; Coker, Robert; Huff, Tim; Miller, Lee

    2016-01-01

    A long-term goal for NASA is to enable crewed missions to Mars: first to the vicinity of Mars, and then to the Mars surface. These missions present new challenges for all aspects of spacecraft design in comparison with the International Space Station, as resupply is unavailable in the transit phase, and early return is not possible. Additionally, mass, power, and volume must be minimized for all phases to reduce propulsion needs. Mass reduction is particularly crucial for Mars surface landing and liftoff due to the challenges inherent in these operations for even much smaller payloads. In this paper we describe current and planned developments in the area of carbon dioxide removal to support future crewed Mars missions. Activities are also described that apply to both the resolution of anomalies observed in the ISS CDRA and the design of life support systems for future missions.

  12. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    International Nuclear Information System (INIS)

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; Karssemeijer, Nico; Heeten, Gerard den

    2016-01-01

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity

  13. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    Energy Technology Data Exchange (ETDEWEB)

    Mordang, Jan-Jurre, E-mail: Jan-Jurre.Mordang@radboudumc.nl; Gubern-Mérida, Albert; Karssemeijer, Nico [Diagnostic Image Analysis Group, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen 6525 GA (Netherlands); Heeten, Gerard den [The National Training Centre for Breast Cancer Screening, Nijmegen 6503 GJ, The Netherlands and Department of Radiology, Amsterdam Medical Center, Amsterdam 1100 DD (Netherlands)

    2016-04-15

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity

  14. [Treatment of removable partial dentures. 2. Causes and consequences of a reduced occlusal system

    NARCIS (Netherlands)

    Witter, D.J.; Barel, J.C.; Baat, C. de; Keltjens, H.M.A.M.; Creugers, N.H.J.

    2011-01-01

    The occlusal system is part of the orofacial system and consists of the maxillary and mandibular alveolar ridge and teeth which are occluding or not or the removable denture teeth. The most prevalent causes of loss of teeth are insufficient oral self care or inadequate professional oral healthcare

  15. Regenerating an Arsenic Removal Iron-Based Adsorptive Media System, Part 2: Performance and Cost

    Science.gov (United States)

    The replacement of exhausted, adsorptive media used to remove arsenic from drinking water accounts for approximately 80% of the total operational and maintenance (O/M) costs of this commonly used small system technology. The results of three, full scale system studies of an on-s...

  16. Reliability evaluation of power supply and distribution for special heat removal systems in nuclear power stations

    International Nuclear Information System (INIS)

    Jazbec, D.

    1982-01-01

    An example of the power supply and distribution of a Special Emergency Heat Removal System (SEHR) shows how an engineering organization may, with the aid of the analytical method of min-cut sets optimize the system reliability. Herein are given the necessary simple calculation methods. (Auth.)

  17. Solvent cleaning system and method for removing contaminants from solvent used in resin recycling

    Science.gov (United States)

    Bohnert, George W [Harrisonville, MO; Hand, Thomas E [Lee's Summit, MO; DeLaurentiis, Gary M [Jamestown, CA

    2009-01-06

    A two step solvent and carbon dioxide based system that produces essentially contaminant-free synthetic resin material and which further includes a solvent cleaning system for periodically removing the contaminants from the solvent so that the solvent can be reused and the contaminants can be collected and safely discarded in an environmentally safe manner.

  18. A passive decay-heat removal system for an ABWR based on air cooling

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, Hiroyasu, E-mail: mochizki@u-fukui.ac.jp [Research Institute of Nuclear Engineering, University of Fukui, 1-2-4 Kanawa-cho, Tsuruga, Fukui 914-0055 (Japan); Yano, Takahiro [School of Engineering, University of Fukui, 1-2-4 Kanawa-cho, Tsuruga, Fukui 914-0055 (Japan)

    2017-01-15

    Highlights: • A passive decay heat removal system for an ABWR is discussed using combined system of the reactor and an air cooler. • Effect of number of pass of the finned heat transfer tubes on heat removal is investigated. • The decay heat can be removed by air coolers with natural convection. • Two types of air cooler are evaluated, i.e., steam condensing and water cooling types. • Measures how to improve the heat removal rate and to make compact air cooler are discussed. - Abstract: This paper describes the capability of an air cooling system (ACS) operated under natural convection conditions to remove decay heat from the core of an Advanced Boiling Water Reactor (ABWR). The motivation of the present research is the Fukushima Severe Accident (SA). The plant suffered damages due to the tsunami and entered a state of Station Blackout (SBO) during which seawater cooling was not available. To prevent this kind of situation, we proposed a passive decay heat removal system (DHRS) in the previous study. The plant behavior during the SBO was calculated using the system code NETFLOW++ assuming an ABWR with the ACS. However, decay heat removal under an air natural convection was difficult. In the present study, a countermeasure to increase heat removal rate is proposed and plant transients with the ACS are calculated under natural convection conditions. The key issue is decreasing pressure drop over the tube banks in order to increase air flow rate. The results of the calculations indicate that the decay heat can be removed by the air natural convection after safety relief valves are actuated many times during a day. Duct height and heat transfer tube arrangement of the AC are discussed in order to design a compact and efficient AC for the natural convection mode. As a result, a 4-pass heat transfer tubes with 2-row staggered arrangement is the candidate of the AC for the DHRS under the air natural convection conditions. The heat removal rate is re-evaluated as

  19. Reliability assessment on decay heat removal system of a fast reactor

    International Nuclear Information System (INIS)

    Hioki, Kazumasa

    1991-01-01

    The reliability of a decay heat removal system (DHRS) is influenced by the success criteria, the components which constitute the system, the support systems configuration, and the mission time. Assessments were performed to investigate quantitatively the effects of these items. Failure probabilities of DHRS under forced or natural circulation modes were calculated and then components and systems of large importance for each mode were identified. (author)

  20. Technology for meat-grinding systems to improve removal of hard particles from ground meat.

    Science.gov (United States)

    Zhao, Y; Sebranek, J G

    1997-03-01

    With increased consumption of ground meat, especially ground beef, quality issues for these products have become more important to industry and consumers alike. Ground meats are usually obtained from relatively low-value cuts and trimmings, and may on occasion contain undesirable hard particles. Hard particles in coarse-ground meat products may include bone chips or fragments, cartilage and dense connective tissue; all of which are considered undesirable defects and which can be reduced by utilizing hard-particle removal systems during grinding operations. This review discusses the principles of hard-particle separation from ground meat, the factors which influence performance of particle separation and some commercially available particle removal systems. Product and processing parameters such as initial bone and connective tissue content, fat content, temperature, pre-grinding size and grinder knife design are considered important for removing hard particles effectively. Pressure gradient on the grinder knife/plate interface was found to play a significant role in particle separation from soft (fat and lean) tissue. Various commercial systems, which are classified as central removal and periphery removal systems, are also discussed. Finally, the authors suggest some processing considerations for meat grinding to help achieve the best quality ground meat for consumers' satisfaction.

  1. Applicability of Zeolite Based Systems for Ammonia Removal and Recovery From Wastewater.

    Science.gov (United States)

    Das, Pallabi; Prasad, Bably; Singh, Krishna Kant Kumar

    2017-09-01

      Ammonia discharged in industrial effluents bears deleterious effects and necessitates remediation. Integrated systems devoted to recovery of ammonia in a useful form and remediation of the same addresses the challenges of waste management and its utilization. A comparative performance evaluation study was undertaken to access the suitability of different zeolite based systems (commercial zeolites and zeolites synthesized from fly ash) for removal of ammonia followed by its subsequent release. Four main parameters which were studied to evaluate the applicability of such systems for large scale usage are cost-effectiveness, ammonia removal efficiency, performance on regeneration, and ammonia release percentage. The results indicated that synthetic zeolites outperformed zeolites synthesized from fly ash, although the later proved to be more efficient in terms of total cost incurred. Process technology development in this direction will be a trade-of between cost and ammonia removal and release efficiencies.

  2. Effect of operational cycle time length on nitrogen removal in an alternating oxidation ditch system.

    Science.gov (United States)

    Mantziaras, I D; Stamou, A; Katsiri, A

    2011-06-01

    This paper refers to nitrogen removal optimization of an alternating oxidation ditch system through the use of a mathematical model and pilot testing. The pilot system where measurements have been made has a total volume of 120 m(3) and consists of two ditches operating in four phases during one cycle and performs carbon oxidation, nitrification, denitrification and settling. The mathematical model consists of one-dimensional mass balance (convection-dispersion) equations based on the IAWPRC ASM 1 model. After the calibration and verification of the model, simulation system performance was made. Optimization is achieved by testing operational cycles and phases with different time lengths. The limits of EU directive 91/271 for nitrogen removal have been used for comparison. The findings show that operational cycles with smaller time lengths can achieve higher nitrogen removals and that an "equilibrium" between phase time percentages in the whole cycle, for a given inflow, must be achieved.

  3. Nitrogen removal and nitrate leaching for forage systems receiving dairy effluent.

    Science.gov (United States)

    Woodard, Kenneth R; French, Edwin C; Sweat, Lewin A; Graetz, Donald A; Sollenberger, Lynn E; Macoon, Bisoondat; Portier, Kenneth M; Wade, Brett L; Rymph, Stuart J; Prine, Gordon M; Van Horn, Harold H

    2002-01-01

    Florida dairies need year-round forage systems that prevent loss of N to ground water from waste effluent sprayfields. Our purpose was to quantify forage N removal and monitor nitrate N (NO3(-)-N) concentrations in soil water below the rooting zone for two forage systems during four 12-mo cycles (1996-2000). Soil in the sprayfield is an excessively drained Kershaw sand (thermic, uncoated Typic Quartzipsamment). Over four cycles, average loading rates of effluent N were 500, 690, and 910 kg ha(-1) per cycle. Nitrogen removed by the bermudagrass (Cynodon spp.)-rye (Secale cereale L.) system (BR) during the first three cycles was 465 kg ha(-1) per cycle for the low loading rate, 528 kg ha(-1) for the medium rate, and 585 kg ha(-1) for the high. For the corn (Zea mays L.)-forage sorghum [Sorghum bicolor (L.) Moench]-rye system (CSR), N removals were 320 kg ha(-1) per cycle for the low rate, 327 kg ha(-1) for the medium, and 378 kg ha(-1) for the high. The higher N removals for BR were attributed to higher N concentration in bermudagrass (18.1-24.2 g kg(-1)) than in corn and forage sorghum (10.3-14.7 g kg(-1)). Dry matter yield declined in the fourth cycle for bermudagrass but N removal continued to be higher for BR than CSR. The BR system was much more effective at preventing NO3(-)-N leaching. For CSR, NO3(-)-N levels in soil water (1.5 m below surface) increased steeply during the period between the harvest of one forage and canopy dosure of the next. Overall, the BR system was better than CSR at removing N from the soil and maintaining low NO3(-)-N concentrations below the rooting zone.

  4. Study on decay heat removal capability of reactor vessel auxiliary cooling system

    International Nuclear Information System (INIS)

    Nishi, Y.; Kinoshita, I.

    1991-01-01

    The reactor vessel auxiliary cooling system (RVACS) is a simple, Passive decay heat removal system for an LMFBR. However, the heat removal capacity of this system is small compared to that of an immersed type of decay heat exchanger. In this study, a high-porosity porous body is proposed to enhance the RVACS's heat transfer performance to improve its applicability. The objectives of this study are to propose a new method which is able to use thermal radiation effectively, to confirm its heat removal capability and to estimate its applicability limit of RVACS for an LMFBR. Heat transfer tests were conducted in an experimental facility with a 3.5 m heat transfer height to evaluate the heat transfer performance of the high-porosity porous body. Using the experimental results, plant transient analyses were performed for a 300 MWe pool type LMFBR under a Total Black Out (TBO) condition to confirm the heat removal capability. Furthermore, the relationship between heat removal capability and thermal output of a reactor were evaluated using a simple parameter model

  5. A multi-process phytoremediation system for removal of polycyclic aromatic hydrocarbons from contaminated soils

    International Nuclear Information System (INIS)

    Huang Xiaodong; El-Alawi, Yousef; Penrose, Donna M.; Glick, Bernard R.; Greenberg, Bruce M.

    2004-01-01

    To improve phytoremediation processes, multiple techniques that comprise different aspects of contaminant removal from soils have been combined. Using creosote as a test contaminant, a multi-process phytoremediation system composed of physical (volatilization), photochemical (photooxidation) and microbial remediation, and phytoremediation (plant-assisted remediation) processes was developed. The techniques applied to realize these processes were land-farming (aeration and light exposure), introduction of contaminant degrading bacteria, plant growth promoting rhizobacteria (PGPR), and plant growth of contaminant-tolerant tall fescue (Festuca arundinacea). Over a 4-month period, the average efficiency of removal of 16 priority PAHs by the multi-process remediation system was twice that of land-farming, 50% more than bioremediation alone, and 45% more than phytoremediation by itself. Importantly, the multi-process system was capable of removing most of the highly hydrophobic, soil-bound PAHs from soil. The key elements for successful phytoremediation were the use of plant species that have the ability to proliferate in the presence of high levels of contaminants and strains of PGPR that increase plant tolerance to contaminants and accelerate plant growth in heavily contaminated soils. The synergistic use of these approaches resulted in rapid and massive biomass accumulation of plant tissue in contaminated soil, putatively providing more active metabolic processes, leading to more rapid and more complete removal of PAHs. - Persistent PAH contaminants in soils can be removed more completely and rapidly by using multiple remediation processes

  6. Natural Organic Matter Removal and Fouling in a Low Pressure Hybrid Membrane Systems

    Directory of Open Access Journals (Sweden)

    Vedat Uyak

    2014-01-01

    Full Text Available The objective of this study was to investigate powdered activated carbon (PAC contribution to natural organic matter (NOM removal by a submerged MF and UF hybrid systems. It was found that filtration of surface waters by a bare MF and UF membranes removed negligible TOC; by contrast, significant amounts of TOC were removed when daily added PAC particles were predeposited on the membrane surfaces. These results support the assumption that the membranes surface properties and PAC layer structure might have considerably influential factor on NOM removal. Moreover, it was concluded that the dominant removal mechanism of hybrid membrane system is adsorption of NOM within PAC layer rather than size exclusion of NOM by both of membrane pores. Transmembrane pressure (TMP increases with PAC membrane systems support the view that PAC adsorption pretreatment will not prevent the development of membrane pressure; on the contrary, PAC particles themselves caused membrane fouling by blocking the entrance of pores of MF and UF membranes. Although all three source waters have similar HPI content, it appears that the PAC interaction with the entrance of membrane pores was responsible for offsetting the NOM fractional effects on membrane fouling for these source waters.

  7. Heavy metal removal in an UASB-CW system treating municipal wastewater.

    Science.gov (United States)

    de la Varga, D; Díaz, M A; Ruiz, I; Soto, M

    2013-10-01

    The objective of the present study was to investigate for the first time the long-term removal of heavy metals (HMs) in a combined UASB-CW system treating municipal wastewater. The research was carried out in a field pilot plant constituted for an up-flow anaerobic sludge bed (UASB) digester as a pretreatment, followed by a surface flow constructed wetland (CW) and finally by a subsurface flow CW. While the UASB showed (pseudo) steady state operational conditions and generated a periodical purge of sludge, CWs were characterised by the progressive accumulation and mineralisation of retained solids. This paper analyses the evolution of HM removal from the water stream over time (over a period of 4.7 year of operation) and the accumulation of HMs in UASB sludge and CW sediments at two horizons of 2.7 and 4.0 year of operation. High removal efficiencies were found for some metals in the following order: Sn > Cr > Cu > Pb > Zn > Fe (63-94%). Medium removal efficiencies were registered for Ni (49%), Hg (42%), and Ag (40%), and finally Mn and As showed negative percentage removals. Removal efficiencies of total HMs were higher in UASB and SF units and lower in the last SSF unit. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Microbial metabolism and activity in terms of nitrate removal in bioelectrochemical systems

    International Nuclear Information System (INIS)

    Huang, Baocheng; Feng, Huajun; Ding, Yangcheng; Zheng, Xin; Wang, Meizhen; Li, Na; Shen, Dongsheng; Zhang, Haiyang

    2013-01-01

    Highlights: • Influence of current on biofilm formation in BES was investigated. • Biofilm formation activity supplying with organic differed with inorganic. • Discussed the influence of signaling molecule and EPS on biofilm formation. -- Abstract: Bioelectrochemical systems (BESs) are a promising technology for generating energy while treating wastewater. By utilizing the electron transfer between the anode and cathode, nitrate can be effectively removed from the BES. Our previous studies show that the carbon source and C/N ratio influences nitrate removal performance. The study presented here investigates how biofilm formation, nitrate removal and signaling molecule release are related in the BESs fed with glucose, starch and HCO 3 − . The results indicate that increasing the current can benefit signaling molecule (DSF) release and extracellular polymeric substances (EPS) excretion, which improves biofilm formation. However, when the current exceeds the optimum value, the influence becomes adverse. Nitrate removal was also improved with increased current, though different carbon sources showed different trends. The highest nitrate removal efficiency of 1.23 ± 0.27, 1.38 ± 0.09, 1.80 ± 0.02 mmol L −1 d −1 for the BESs fed with glucose, starch and HCO 3 − were achieved, respectively. This paper studied the bacterial habits in a BES to better acquire and regulate the reaction process, with the aim of achieving good pollutant removal performance

  9. The TDAQ Baseline Architecture

    CERN Multimedia

    Wickens, F J

    The Trigger-DAQ community is currently busy preparing material for the DAQ, HLT and DCS TDR. Over the last few weeks a very important step has been a series of meetings to complete agreement on the baseline architecture. An overview of the architecture indicating some of the main parameters is shown in figure 1. As reported at the ATLAS Plenary during the February ATLAS week, the main area where the baseline had not yet been agreed was around the Read-Out System (ROS) and details in the DataFlow. The agreed architecture has: Read-Out Links (ROLs) from the RODs using S-Link; Read-Out Buffers (ROB) sited near the RODs, mounted in a chassis - today assumed to be a PC, using PCI bus at least for configuration, control and monitoring. The baseline assumes data aggregation, in the ROB and/or at the output (which could either be over a bus or in the network). Optimization of the data aggregation will be made in the coming months, but the current model has each ROB card receiving input from 4 ROLs, and 3 such c...

  10. Evaluation of Phosphate and Nitrate Removal Capacity of Anodonta cygnea (Unionidae in Open and Closed Systems

    Directory of Open Access Journals (Sweden)

    Arash Javanshir

    2008-06-01

    Full Text Available Discharge of agricultural and industrial effluents into surface water resources cause water quality degradation. The swan mussel (Anodonta cygnea is one of the most important fresh water suspension feeders that can be used for the purpose of pollutant reduction. In order to evaluate the capability of A. cygnea in the reduction of nitrates and phosphates in municipal wastewater, several breeds & Rhyter culture medium were investigated. The results obtained from the open system showed that the growing fresh algae were capable of removing a considerable portion of the dissolved materials. The combined system of mussels and algae had an average nitrate removal efficiency of 76.3% and a phosphate removal efficiency of 75.3%. Based on our results, this breed of mussels may be recommended as a crucial organism in biological wastewater treatment.

  11. An in vitro study: Evaluation of intracanal calcium hydroxide removal with different file systems

    Directory of Open Access Journals (Sweden)

    Atul Jain

    2017-01-01

    Full Text Available Background: Calcium hydroxide (Ca(OH2 is the most commonly used intracanal material; it needs to be removed in entirety before obturation. Several techniques have been used for the same including use of various hand and rotary files. Aim: This study was carried out to compare the efficacy of Hand K files and single and multiple rotary file system in removal of Ca(OH2. Methodology: Distobuccal root of 45 maxillary molars were selected on the basis of specified inclusion and exclusion criteria. They were divided into three groups - Group 1 (H and K file, Group 2 (HERO Shaper, and Group 3 (One Shape. Biomechanical preparation (BMP was carried out as per the manufacturer's instructions; 2.5% sodium hypochlorite was used as the irrigant and 17% ethylenediaminetetraacetic acid as the penultimate irrigant. Ca(OH2powder was mixed with normal saline to obtain a paste; canals were filled with this paste using a Lentulo spiral and were sealed. After 7 days, Ca(OH2was removed, using the same file system as that used for BMP. Samples were sectioned longitudinally and evaluated under a stereomicroscope. Statistical Analysis: Statistical analysis of the obtained data was carried out using one-way analysis of variance test. Results: HERO Shaper displayed better removal of Ca(OH2than One Shape and Hand K file. Moreover, removal was better in the middle third of canal than apical third. Conclusion: Multiple rotary file system (HERO Shaper is more effective in removal of Ca(OH2than the single file system (One Shape

  12. Preliminary screening of small-scale domestic wastewater treatment systems for removal of pharmaceutical and personal care products

    DEFF Research Database (Denmark)

    Matamoros, Victor; Arias, Carlos Alberto; Brix, Hans

    2009-01-01

    , two biological sand filters, five horizontal subsurface flow and four vertical flow constructed wetlands. As expected, all systems removed TSS and BOD5 efficiently (>95% removal). The PPCP removal efficiencies exceeded 80% with the exception of carbamazepine, diclofenac and ketoprofen because...

  13. Methyl-orange and cadmium simultaneous removal using fly ash and photo-Fenton systems

    International Nuclear Information System (INIS)

    Visa, Maria; Duta, Anca

    2013-01-01

    Highlights: ► The mixed substrates of FA-M + TiO 2 proved to be highly efficient in adsorption. ► FA-M + photo-Fenton are a low-cost material for advanced treatment of wastewater. ► The adsorbed MO may act as a complexion agent, increasing the affinity for metals. ► Dye removal by photodegradation is the favourable mechanism compared to adsorption. -- Abstract: Wastewaters resulting from the textile and dye finishing industries need complex treatment for efficient removal of colour and other compounds existent in the dyeing and rising baths (heavy metals, surfactants, equalizers, etc.). Modified fly ash (FA) mixed with TiO 2 photocatalyst represent a viable option for simultaneous removal of dyes and heavy metals, and the optimized conditions are discussed in this paper for synthetic wastewaters containing methyl-orange (MO) and cadmium. For a cost-effective dye removal process, further tests were done, replacing the photocatalyst with a (photo)Fenton system. The optimized technological parameters (contact time, amount of fly ash and amount of Fe 2+ /H 2 O 2 ) allow to reach removal efficiencies up to 88% for the heavy metal and up to 70% for the dye. The adsorption mechanisms and the process kinetic are discussed, also considering the possibility of in situ generation of the Fenton system, due to the fly ash composition

  14. Methyl-orange and cadmium simultaneous removal using fly ash and photo-Fenton systems

    Energy Technology Data Exchange (ETDEWEB)

    Visa, Maria, E-mail: visamro2000@yahoo.com [Transilvania University of Brasov, Department of Renewable Energy Systems and Recycling, Eroilor 29, 500036 Brasov (Romania); Duta, Anca, E-mail: a.duta@unitbv.ro [Transilvania University of Brasov, Department of Renewable Energy Systems and Recycling, Eroilor 29, 500036 Brasov (Romania)

    2013-01-15

    Highlights: ► The mixed substrates of FA-M + TiO{sub 2} proved to be highly efficient in adsorption. ► FA-M + photo-Fenton are a low-cost material for advanced treatment of wastewater. ► The adsorbed MO may act as a complexion agent, increasing the affinity for metals. ► Dye removal by photodegradation is the favourable mechanism compared to adsorption. -- Abstract: Wastewaters resulting from the textile and dye finishing industries need complex treatment for efficient removal of colour and other compounds existent in the dyeing and rising baths (heavy metals, surfactants, equalizers, etc.). Modified fly ash (FA) mixed with TiO{sub 2} photocatalyst represent a viable option for simultaneous removal of dyes and heavy metals, and the optimized conditions are discussed in this paper for synthetic wastewaters containing methyl-orange (MO) and cadmium. For a cost-effective dye removal process, further tests were done, replacing the photocatalyst with a (photo)Fenton system. The optimized technological parameters (contact time, amount of fly ash and amount of Fe{sup 2+}/H{sub 2}O{sub 2}) allow to reach removal efficiencies up to 88% for the heavy metal and up to 70% for the dye. The adsorption mechanisms and the process kinetic are discussed, also considering the possibility of in situ generation of the Fenton system, due to the fly ash composition.

  15. Dissolved nutrients and atrazine removal by column-scale monophasic and biphasic rain garden model systems.

    Science.gov (United States)

    Yang, Hanbae; McCoy, Edward L; Grewal, Parwinder S; Dick, Warren A

    2010-08-01

    Rain gardens are bioretention systems that have the potential to reduce peak runoff flow and improve water quality in a natural and aesthetically pleasing manner. We compared hydraulic performance and removal efficiencies of nutrients and atrazine in a monophasic rain garden design versus a biphasic design at a column-scale using simulated runoff. The biphasic rain garden was designed to increase retention time and removal efficiency of runoff pollutants by creating a sequence of water saturated to unsaturated conditions. We also evaluated the effect of C substrate availability on pollutant removal efficiency in the biphasic rain garden. Five simulated runoff events with various concentrations of runoff pollutants (i.e. nitrate, phosphate, and atrazine) were applied to the monophasic and biphasic rain gardens once every 5d. Hydraulic performance was consistent over the five simulated runoff events. Peak flow was reduced by approximately 56% for the monophasic design and 80% for the biphasic design. Both rain garden systems showed excellent removal efficiency of phosphate (89-100%) and atrazine (84-100%). However, significantly (prain garden (29-39%). Addition of C substrate in the form of glucose increased removal efficiency of nitrate significantly (prain gardens. (c) 2010 Elsevier Ltd. All rights reserved.

  16. Unavailability of the residual system heat removal of Angra 1 by Bayesian networks considering dependent failures

    International Nuclear Information System (INIS)

    Gomes, Many R.S.; Melo, Paulo F.F.F. e

    2015-01-01

    This work models by Bayesian networks the residual heat removal system (SRCR) of Angra I nuclear power plant, using fault tree mapping for systematically identifying all possible modes of occurrence caused by a large loss of coolant accident (large LOCA). The focus is on dependent events, such as the bridge system structure of the residual heat removal system and the occurrence of common-cause failures. We used the Netica™ tool kit, Norsys Software Corporation and Python 2.7.5 for modeling Bayesian networks and Microsoft Excel for modeling fault trees. Working with dependent events using Bayesian networks is similar to the solutions proposed by other models, beyond simple understanding and ease of application and modification throughout the analysis. The results obtained for the unavailability of the system were satisfactory, showing that in most cases the system will be available to mitigate the effects of an accident as described above. (author)

  17. BOA: Asbestos pipe-insulation removal robot system, Phase 2. Topical report, January--June 1995

    Energy Technology Data Exchange (ETDEWEB)

    Schempf, H.; Bares, J.E.

    1995-06-01

    This report explored the regulatory impact and cost-benefit of a robotic thermal asbestos pipe-insulation removal system over the current manual abatement work practice. The authors are currently in the second phase of a two-phase program to develop a robotic asbestos abatement system, comprised of a ground-based support system (including vacuum, fluid delivery, computing/electronics/power, and other subsystems) and several on-pipe removal units, each sized to handle pipes within a given diameter range. The intent of this study was to (i) aid in developing design and operational criteria for the overall system to maximize cost-efficiency, and (ii) to determine the commercial potential of a robotic pipe-insulation abatement system.

  18. Design of Passive Decay Heat Removal System using Mercury Thermosyphon for SFR

    Energy Technology Data Exchange (ETDEWEB)

    You, Byung Hyun; Jeong, Yong Hoon [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2013-10-15

    In this study, thermosyphon application is suggested to accomplish the fully passive safety grade system and compactness of components via enhance the heat removal performance. A two-phase evaporating thermosyphon operates when the evaporator is heated, the working fluid start boiling, the vapor that is formed moves to the condenser, where it is condensed on the walls, giving up the heat of phase change to the cooling fluid. Gravity forces cause the condensate to condensed liquid flow to the evaporator again. These processes occur continuously, which causes transfer of heat from evaporator to condenser vice versa. After the thermal design and performance evaluation, the results were compared with the performance of conventional DRACS system. For the same amount of decay heat removal performance of PDRC system of KALIMER-600 mercury thermosyphon system can archive around 30∼50% of compactness. For the detailed design, improved analytical model and experimental data for the validation will be required to specify the new DHR system.

  19. Unavailability of the residual system heat removal of Angra 1 by Bayesian networks considering dependent failures

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Many R.S.; Melo, Paulo F.F.F. e, E-mail: mgomes@con.ufrj.br, E-mail: frutuoso@nuclear.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Programa de Pos-Graduacao em Engenharia Nuclear

    2015-07-01

    This work models by Bayesian networks the residual heat removal system (SRCR) of Angra I nuclear power plant, using fault tree mapping for systematically identifying all possible modes of occurrence caused by a large loss of coolant accident (large LOCA). The focus is on dependent events, such as the bridge system structure of the residual heat removal system and the occurrence of common-cause failures. We used the Netica™ tool kit, Norsys Software Corporation and Python 2.7.5 for modeling Bayesian networks and Microsoft Excel for modeling fault trees. Working with dependent events using Bayesian networks is similar to the solutions proposed by other models, beyond simple understanding and ease of application and modification throughout the analysis. The results obtained for the unavailability of the system were satisfactory, showing that in most cases the system will be available to mitigate the effects of an accident as described above. (author)

  20. Removal of nitrogen and phosphorus from dairy wastewater using constructed wetlands systems operating in batch

    Directory of Open Access Journals (Sweden)

    Ronaldo Rocha Bastos

    2012-08-01

    Full Text Available This work presents the results of a study conducted for a period of seven months on the effectiveness of constructed wetland systems for the treatment of dairy wastewater aiming at removing, nitrogen and phosphorus. Six experimental systems were assembled with a net volume of 115 L using HDPE tanks, with length/width ratio of 2:1. In three of the systems, gravel 0 was used as substrate, while gravel 0 and sand was used in the three others, in the percentage of 80% and 20%, respectively. The systems were operated in batch cycles of 48 hours, applying 7.5 L of influent per cycle. Four of the experimental units were cultivated, and two kept as controls. The selected species chosen were the macrophytes, Typha domingensis and Hedychium coronarium. The removal efficiency concerning nitrogen compounds showed to be quite promising with values ranging from 29.4 to 73.4%, while phosphorus removal from the beds was lower, reaching efficiencies between 18.61 and 34.3%, considered good values, since the removal of these substances is quite difficult through conventional treatment.

  1. URANIUM REMOVAL FROM DRINKING WATER USING A SMALL FULL-SCALE SYSTEM

    Science.gov (United States)

    This report presents background and history of water quality, the basis for design and nine months of actual operating data for a small, full-scale strong-base ion exchange system that is used to remove uranium from a water supply serving a school in Jefferson County, CO. Informa...

  2. Integrated nitrogen removal biofilter system with ceramic membrane for advanced post-treatment of municipal wastewater.

    Science.gov (United States)

    Son, Dong-Jin; Yun, Chan-Young; Kim, Woo-Yeol; Zhang, Xing-Ya; Kim, Dae-Gun; Chang, Duk; Sunwoo, Young; Hong, Ki-Ho

    2016-12-01

    The pre-denitrification biofilm process for nitrogen removal was combined with ceramic membrane with pore sizes of 0.05-0.1 µm as a system for advanced post-treatment of municipal wastewater. The system was operated under an empty bed hydraulic retention time of 7.8 h, recirculation ratio of 3, and transmembrane pressure of 0.47 bar. The system showed average removals of organics, total nitrogen, and solids as high as 93%, 80%, and 100%, respectively. Rapid nitrification could be achieved and denitrification was performed in the anoxic filter without external carbon supplements. The residual particulate organics and nitrogen in effluent from biofilm process could be also removed successfully through membrane filtration and the removal of total coliform was noticeably improved after membrane filtration. Thus, a system composed of the pre-denitrification biofilm process with ceramic membrane would be a compact and flexible option for advanced post-treatment of municipal wastewater.

  3. 75 FR 71353 - Office of the Attorney General; Certification Process for State Capital Counsel Systems; Removal...

    Science.gov (United States)

    2010-11-23

    ... the Attorney General; Certification Process for State Capital Counsel Systems; Removal of Final Rule... only if the Attorney General has certified ``that [the] State has established a mechanism for providing... State to qualify for the special habeas procedures, the Attorney General must determine that ``the State...

  4. 75 FR 29217 - Office of the Attorney General; Certification Process for State Capital Counsel Systems; Removal...

    Science.gov (United States)

    2010-05-25

    ... Office of the Attorney General; Certification Process for State Capital Counsel Systems; Removal of Final Rule AGENCY: Office of the Attorney General, Department of Justice. ACTION: Notice of proposed... the Attorney General has certified ``that [the] State has established a mechanism for providing...

  5. Aging assessment of Residual Heat Removal systems in Boiling Water Reactors

    International Nuclear Information System (INIS)

    Lofaro, R.J.; Aggarwal, S.

    1992-01-01

    The effects of aging on Residual Heat Removal systems in Boiling Water Reactors have been studied as part of the Nuclear Plant Aging Research Program. The aging phenomena has been characterized by analyzing operating experience from various national data bases. In addition, actual plant data was obtained to supplement and validate the data base findings

  6. REMOVAL OF ARSENIC IN DRINKING WATER: ARS CFU-50 APC ELECTROFLOCCULATION AND FILTRATION WATER TREATMENT SYSTEM

    Science.gov (United States)

    ETV testing of the ARS CFU-50 APC Electroflocculation and Filtration Water Treatment System (ARS CFU-50 APC) for arsenic removal was conducted at the Town of Bernalillo Well #3 site from April 18 through May 2, 2006. The source water was chlorinated groundwater from two supply w...

  7. Regenerating an Arsenic Removal Iron-Based Adsorptive Media System, Part 1: The Regeneration Process

    Science.gov (United States)

    Adsorptive media technology is a frequently used method of removing arsenic by small water systems because of its simplicity and efficiency. Current practice is to replace the media when it no longer reduces arsenic below the USEPA drinking water maximum contaminant level (MCL) ...

  8. Capital and Operating Costs of Small Arsenic Removal Adsorptive Media Systems

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) conducted 50 full-scale demonstration projects on treatment systems removing arsenic from drinking water in 26 states throughout the U.S. The projects were conducted to evaluate the performance, reliability, and cost of arsenic remo...

  9. Microbial community changes in biological phosphate-removal systems on altering sludge phosphorus content

    NARCIS (Netherlands)

    Liu, WT; Linning, KD; Nakamura, K; Mino, T; Matsuo, T; Forney, LJ

    Biomarkers (respiratory quinones and cellular fatty acids) and denaturing gradient gel electrophoresis (DGGE) of PCR-amplified 16S rRNA genes were used to characterize the microbial community structure of lab-scale enhanced biological phosphate-removal (EBPR) systems in response to altering sludge

  10. 75 FR 73972 - Hazardous Waste Management System; Identification and Listing of Hazardous Waste; Removal of...

    Science.gov (United States)

    2010-11-30

    ... Waste Management System; Identification and Listing of Hazardous Waste; Removal of Direct Final.... Lists of Subjects in 40 CFR Part 261 Environmental Protection, Hazardous waste, Recycling, Reporting and... follows: PART 261--IDENTIFICATION AND LISTING OF HAZARDOUS WASTE 0 1. The authority citation for part 261...

  11. Model-based optimization biofilm based systems performing autotrophic nitrogen removal using the comprehensive NDHA model

    DEFF Research Database (Denmark)

    Valverde Pérez, Borja; Ma, Yunjie; Morset, Martin

    Completely autotrophic nitrogen removal (CANR) can be obtained in single stage biofilm-based bioreactors. However, their environmental footprint is compromised due to elevated N2O emissions. We developed novel spatially explicit biochemical process model of biofilm based CANR systems that predicts...

  12. Experimental research on passive residual heat remove system for advanced PWR

    International Nuclear Information System (INIS)

    Huang Yanping; Zhuo Wenbin; Yang Zumao; Xiao Zejun; Chen Bingde

    2003-01-01

    The experimental and qualified results of MISAP in the research of passive residual heat remove system of advanced PWR performed in the Bubble physics and natural circulation laboratory in Nuclear Power Institute of China in the past ten years is overviewed. Further researches for engineering research and design are also suggested

  13. Baseline restoration technique based on symmetrical zero-area trapezoidal pulse shaper

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Guoqiang, E-mail: 24829500@qq.com [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China); Yang, Jian, E-mail: 22105653@qq.com [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China); Hu, Tianyu; Ge, Liangquan [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China); Ouyang, Xiaoping [Northwest Institute of Nuclear Technology, Xi’an 710024,China (China); Zhang, Qingxian; Gu, Yi [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China)

    2017-06-21

    Since the baseline of the unipolar pulse shaper have the direct-current (DC) offset and drift, an additional baseline estimator is need to obtain baseline values in real-time. The bipolar zero-area (BZA) pulse shapers can be used for baseline restoration, but they cannot restrain the baseline drift due to their asymmetrical shape. In this study, three trapezoids are synthesized as a symmetrical zero-area (SZA) shape, which can remove the DC offset and restrain the baseline drift. This baseline restoration technique can be easily implemented in digital pulse processing (DPP) systems base on the recursive algorithm. To strengthen our approach, the iron's characteristic x-ray was detected using a Si-PIN diode detector. Compared with traditional trapezoidal pulse shapers, the SZA trapezoidal pulse shaper improved the energy resolution from 237 eV to 216 eV for the 6.403 keV Kα peak.

  14. Passive Decay Heat Removal System Options for S-CO2 Cooled Micro Modular Reactor

    International Nuclear Information System (INIS)

    Moon, Jangsik; Jeong, Yong Hoon; Lee, Jeong Ik

    2014-01-01

    To achieve modularization of whole reactor system, Micro Modular Reactor (MMR) which has been being developed in KAIST took S-CO 2 Brayton power cycle. The S-CO 2 power cycle is suitable for SMR due to high cycle efficiency, simple layout, small turbine and small heat exchanger. These characteristics of S-CO 2 power cycle enable modular reactor system and make reduced system size. The reduced size and modular system motived MMR to have mobility by large trailer. Due to minimized on-site construction by modular system, MMR can be deployed in any electricity demand, even in isolated area. To achieve the objective, fully passive safety systems of MMR were designed to have high reliability when any offsite power is unavailable. In this research, the basic concept about MMR and Passive Decay Heat Removal (PDHR) system options for MMR are presented. LOCA, LOFA, LOHS and SBO are considered as DBAs of MMR. To cope with the DBAs, passive decay heat removal system is designed. Water cooled PDHR system shows simple layout, but has CCF with reactor systems and cannot cover all DBAs. On the other hand, air cooled PDHR system with two-phase closed thermosyphon shows high reliability due to minimized CCF and is able to cope with all DBAs. Therefore, the PDHR system of MMR will follows the air-cooled PDHR system and the air cooled system will be explored

  15. Assessment of the cryogenic distillation system in Cernavoda tritium removal facility

    International Nuclear Information System (INIS)

    Pasca, Gheorghe; Draghia, Mirela; Porcariu, Florina; Ana, George

    2010-01-01

    Full text: This paper aims at presenting an assessment of the Cryogenic Distillation system (CD) in the Cernavoda Tritium Removal Facility (CTRF). The cryogenic distillation system is one of the key components of the CTRF which comprises other systems as: the liquid phase catalytic exchange system, designed to transfer tritium from heavy water to a deuterium stream to be fed into the CD system; the atmosphere detritiation system; the tritium recovery system; the tritium/hydrogen monitoring system; the central interlocking system; the tritium extraction and storage system. Thus, the need to build a tritium separation and recovery system results from economic opportunities offered both by heavy water reuse and tritium production, but, at the same time, it offers an alternative for the storage of tritiated heavy water as radioactive waste. (authors)

  16. Pre-Conceptual Design for Northstar ⁹⁹Mo Process Tritium Removal System

    Energy Technology Data Exchange (ETDEWEB)

    Nobile, Arthur [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reichert, Heidi [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hollis, William Kirk [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Taylor, Craig Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gordon, John Cameron [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-01-12

    In this report we describe a preliminary concept for a Tritium Removal System (TRS) to remove tritium that is generated in the ⁹⁹Mo production process. Preliminary calculations have been performed to evaluate an approximate size for the system. The concept described utilizes well-established detritiation technology based on catalytic oxidation of tritium and tritiated hydrocarbons to water in a high temperature (400 °C) reactor and capture of water in a molecular sieve bed. The TRS concept involves use of a single system that would cycle through each of the seven online target systems and remove tritium that has been accumulated after one week’s run time. The TRS would perform cleanup operations on each target system for a period of approximately 24 hours. This would occur while the system is still online and just prior to target replacement, so tritium levels would at their minimum values for target replacement. In the concept, during normal operation a small fraction (1%) of the helium recirculating in the system would be diverted through the TRS and returned to the flow loop. With this approach sufficient levels of detritiation can be accomplished in a 24 hour period. In the study it was found that because of the need to maintain low oxygen levels in the system (<100 ppm) this increases the size of the catalytic reactor. As a result of this finding, consideration should be given to other methods for removing tritium from the system. Other methods such as catalytic exchange of tritium with an unsaturated organic compound and subsequent trapping on activated carbon or molecular sieve could offer advantages of reducing reactor size and operation at lower reactor temperature. However the most significant advantage of such an approach would be the ability to operate in very low oxygen environments, which would eliminate any concerns for oxidation of the target.

  17. Estimation of characteristics on high temperature filtration system for particle removal in vitrification process

    International Nuclear Information System (INIS)

    Park, Seung Chul; Ryu, Bo Hyun; Park, Byoung Chul; Ryu, Chang Soo; Hwang, Tae Won; Ha, Jong Hyun

    2003-01-01

    High temperature filtration technology has been widely used in nuclear industry systems to remove particulate matter from air and gas streams. Air filters are defined as porous structures through which air is passed to separate out entrained particulate matter. Especially among of them, ceramic candle filters are suitable to gain efficient dust removal at high temperatures and achieve high collection efficiencies for (sub-)micron particles. The paper presents experimental results for their application in the pilot scale vitrification plant operations. Experimental results were transformed into design equations for (i) total pressure drop and the effect of face velocity; (ii) the prediction of the operating parameters

  18. Electrochemical filtration for turbidity removal in industrial cooling/process water systems

    International Nuclear Information System (INIS)

    Kumbhar, A.G.; Venkateswaran, G.

    2008-01-01

    Water samples of large cooling water reservoirs may look visibly clear and transparent, but still may contain sub-micron size particles at sub-parts-per-million levels. Deposition of these particles on heat exchanger surfaces, reduces the heat transfer efficiency in power industry. In nuclear power plants, additionally it creates radiation exposure problems due to activation of fine metallic turbidity in the reactor core and its subsequent transfer to out-of-core surfaces. Sub-micron filtration creates back high-pressure problem. Zeta filters available commercially are prescribed for separating either positively or negatively charged particles. They are of once-use and throw-type. Precipitation surface modified ion exchangers impart chemical impurities to the system. Thus, sub-micron size and dilute turbidity removal from large volumes of waters such as heat exchanger cooling water in nuclear and power industry poses a problem. Electro deposition of the turbidity causing particles, on porous carbon/graphite felt electrodes, is one of the best suited methods for turbidity removal from large volumes of water due to the filter's high permeability, inertness to the system and regenerability resulting in low waste generation. Initially, active indium turbidity removal from RAPS-1 heavy water moderator system, and microbes removal from heat exchanger cooling lake water of RAPS 1 and 2 were demonstrated with in-house designed and fabricated prototype electrochemical filter (ECF). Subsequently, a larger size, high flow filter was fabricated and deployed for iron turbidity removal from active process waters system of Kaiga Generation Station unit 1 and silica and iron turbidity removal from cooling water pond used for heat exchanger of a high temperature high pressure (HTHP) loop at WSCD, Kalpakkam. The ECF proved its exclusive utility for sub-micron size turbidity removal and microbes removal. ECF maneuverability with potential and current for both positively and

  19. Pilot scale test of a produced water-treatment system for initial removal of organic compounds

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Enid J [Los Alamos National Laboratory; Kwon, Soondong [UT-AUSTIN; Katz, Lynn [UT-AUSTIN; Kinney, Kerry [UT-AUSTIN

    2008-01-01

    A pilot-scale test to remove polar and non-polar organics from produced water was performed at a disposal facility in Farmington NM. We used surfactant-modified zeolite (SMZ) adsorbent beds and a membrane bioreactor (MBR) in combination to reduce the organic carbon content of produced water prior to reverse osmosis (RO). Reduction of total influent organic carbon (TOC) to 5 mg/L or less is desirable for efficient RO system operation. Most water disposed at the facility is from coal-bed gas production, with oil production waters intermixed. Up to 20 gal/d of produced water was cycled through two SMZ adsorbent units to remove volatile organic compounds (BTEX, acetone) and semivolatile organic compounds (e.g., napthalene). Output water from the SMZ units was sent to the MBR for removal of the organic acid component of TOC. Removal of inorganic (Mn and Fe oxide) particulates by the SMZ system was observed. The SMZ columns removed up to 40% of the influent TOC (600 mg/L). BTEX concentrations were reduced from the initial input of 70 mg/L to 5 mg/L by the SMZ and to an average of 2 mg/L after the MBR. Removal rates of acetate (input 120-170 mg/L) and TOC (input up to 45 mg/L) were up to 100% and 92%, respectively. The water pH rose from 8.5 to 8.8 following organic acid removal in the MBR; this relatively high pH was likely responsible for observed scaling of the MBR internal membrane. Additional laboratory studies showed the scaling can be reduced by metered addition of acid to reduce the pH. Significantly, organic removal in the MBR was accomplished with a very low biomass concentration of 1 g/L throughout the field trial. An earlier engineering evaluation shows produced water treatment by the SMZ/MBR/RO system would cost from $0.13 to $0.20 per bbl at up to 40 gpm. Current estimated disposal costs for produced water are $1.75 to $4.91 per bbl when transportation costs are included, with even higher rates in some regions. Our results suggest that treatment by an SMZ

  20. Computer Simulation and Modeling of CO2 Removal Systems for Exploration 2013-2014

    Science.gov (United States)

    Coker, R.; Knox, J.; Gomez, C.

    2015-01-01

    The Atmosphere Revitalization Recovery and Environmental Monitoring (ARREM) project was initiated in September of 2011 as part of the Advanced Exploration Systems (AES) program. Under the ARREM project and the follow-on Life Support Systems (LSS) project, testing of sub-scale and full-scale systems has been combined with multiphysics computer simulations for evaluation and optimization of subsystem approaches. In particular, this paper will describes the testing and 1-D modeling of the combined water desiccant and carbon dioxide sorbent subsystems of the carbon dioxide removal assembly (CDRA). The goal is a full system predictive model of CDRA to guide system optimization and development.

  1. Spent Nuclear Fuel (SNF) Removal Campaign Plan

    International Nuclear Information System (INIS)

    PAJUNEN, A.L.

    2000-01-01

    The overall operation of the Spent Nuclear Fuel Project will include fuel removal, sludge removal, debris removal, and deactivation transition activities. Figure 1-1 provides an overview of the current baseline operating schedule for project sub-systems, indicating that a majority of fuel removal activities are performed over an approximately three-and-one-half year time period. The purpose of this document is to describe the strategy for operating the fuel removal process systems. The campaign plan scope includes: (1) identifying a fuel selection sequence during fuel removal activities, (2) identifying MCOs that are subjected to extra testing (process validation) and monitoring, and (3) discussion of initial MCO loading and monitoring in the Canister Storage Building (CSB). The campaign plan is intended to integrate fuel selection requirements for handling special groups of fuel within the basin (e.g., single pass reactor fuel), process validation activities identified for process systems, and monitoring activities during storage

  2. Development of an Electrochemical Ceramic Membrane Filtration System for Efficient Contaminant Removal from Waters.

    Science.gov (United States)

    Zheng, Junjian; Wang, Zhiwei; Ma, Jinxing; Xu, Shaoping; Wu, Zhichao

    2018-04-03

    Inability to remove low-molecular-weight anthropogenic contaminants is a critical issue in low-pressure membrane filtration processes for water treatment. In this work, a novel electrochemical ceramic membrane filtration (ECMF) system using TiO 2 @SnO 2 -Sb anode was developed for removing persistent p-chloroaniline (PCA). Results showed that the ECMF system achieved efficient removal of PCA from contaminated waters. At a charging voltage of 3 V, the PCA removal rate of TiO 2 @SnO 2 -Sb ECMF system under flow-through mode was 2.4 times that of flow-by mode. The energy consumption for 50% of PCA removal for TiO 2 @SnO 2 -Sb ECMF at 3 V under flow-through mode was 0.38 Wh/L, much lower than that of flow-by operation (1.5 Wh/L), which was attributed to the improved utilization of the surface adsorbed HO· and dissociated HO· driven by the enhanced mass transfer of PCA toward the anode surface. Benefiting from the increased production of reactive oxygen species such as O 2 •- , H 2 O 2 , and HO· arising from excitation of anatase TiO 2 , TiO 2 @SnO 2 -Sb ECMF exhibited a superior electrocatalytic activity to the SnO 2 -Sb ECMF system. The degradation pathways of PCA initiated by OH· attack were further proposed, with the biodegradable short-chain carboxylic acids (mainly formic, acetic, and oxalic acids) identified as the dominant oxidized products. These results highlight the potential of the ECMF system for cost-effective water purification.

  3. Design Strategies and Preliminary Prototype for a Low-Cost Arsenic Removal System for Rural Bangladesh

    Energy Technology Data Exchange (ETDEWEB)

    Mathieu, Johanna L.; Gadgil, Ashok J.; Kowolik, Kristin; Qazi, Shefah; Agogino, Alice M.

    2009-09-14

    Researchers have invented a material called ARUBA -- Arsenic Removal Using Bottom Ash -- that effectively and affordably removes arsenic from Bangladesh groundwater. Through analysis of studies across a range of disciplines, observations, and informal interviews conducted over three trips to Bangladesh, we have applied mechanical engineering design methodology to develop eight key design strategies, which were used in the development of a low-cost, community-scale water treatment system that uses ARUBA to removearsenic from drinking water. We have constructed, tested, and analysed a scale version of the system. Experiments have shown that the system is capable of reducing high levels of arsenic (nearly 600 ppb) to below the Bangladesh standard of 50 ppb, while remaining affordable to people living on less than US$2/day. The system could be sustainably implemented as a public-private partnership in rural Bangladesh.

  4. Sorbent Structural Impacts Due to Humidity on Carbon Dioxide Removal Sorbents for Advanced Exploration Systems

    Science.gov (United States)

    Watson, David; Knox, James C.; West, Phillip; Stanley, Christine M.; Bush, Richard

    2015-01-01

    The Life Support Systems Project (LSSP) under the Advanced Exploration Systems (AES) program builds upon the work performed under the AES Atmosphere Resource Recovery and Environmental Monitoring (ARREM) project focusing on the numerous technology development areas. The CO2 removal and associated air drying development efforts are focused on improving the current state-of-the-art system on the International Space Station (ISS) utilizing fixed beds of sorbent pellets by seeking more robust pelletized sorbents, evaluating structured sorbents, and examining alternate bed configurations to improve system efficiency and reliability. A component of the CO2 removal effort encompasses structural stability testing of existing and emerging sorbents. Testing will be performed on dry sorbents and sorbents that have been conditioned to three humidity levels. This paper describes the sorbent structural stability screening efforts in support of the LSS Project within the AES Program.

  5. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012

    DEFF Research Database (Denmark)

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A

    2015-01-01

    BACKGROUND: Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. OBJECTIVE: To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. METHODS: Data of patie......BACKGROUND: Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. OBJECTIVE: To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. METHODS: Data...... of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. RESULTS......: Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance...

  6. Oxygen Limited Bioreactors System For Nitrogen Removal Using Immobilized Mix Culture

    Science.gov (United States)

    Pathak, B. K.; Sumino, T.; Saiki, Y.; Kazama, F.

    2005-12-01

    Recently nutrients concentrations especially nitrogen in natural water is alarming in the world wide. Most of the effort is being done on the removal of high concentration of nitrogen especially from the wastewater treatment plants. The removal efficiency is targeted in all considering the effluent discharge standard set by the national environment agency. In many cases, it does not meet the required standard and receiving water is being polluted. Eutrophication in natural water bodies has been reported even if the nitrogen concentration is low and self purification of natural systems itself is not sufficient to remove the nitrogen due to complex phenomenon. In order to recover the pristine water environment, it is very essential to explore bioreactor systems for natural water systems using immobilized mix culture. Microorganism were entrapped in Polyethylene glycol (PEG) prepolymer gel and cut into 3mm cubic immobilized pellets. Four laboratory scale micro bio-reactors having 0.1 L volumes were packed with immobilized pellets with 50% compact ratio. RUN1, RUN2, RUN3 and RUN4 were packed with immobilized pellets from reservoirs sediments, activated sludge (AS), mixed of AS, AG and biodegradable plastic and anaerobic granules (AG) respectively. Water from Shiokawa Reservoirs was feed to all reactors with supplemental ammonia and nitrite nitrogen as specified in the results and discussions. The reactors were operated dark incubated room in continuous flow mode with hydraulic retention time of 12 hours under oxygen limiting condition. Ammonium, nitrate nitrite nitrogen and total organic carbon (TOC) concentrations were measured as described in APWA and AWWA (1998). Laboratory scale four bioreactors containing different combination of immobilized cell were monitored for 218 days. Influent NH4+-N and NO2--N concentration were 2.27±0.43 and 2.05±0.41 mg/l respectively. Average dissolved oxygen concentration and pH in the reactors were 0.40-2.5 mg/l and pH 6

  7. KIGAM Seafloor Observation System (KISOS) for the baseline study in monitoring of gas hydrate test production in the Ulleung Basin, Korea

    Science.gov (United States)

    Lee, Sung-rock; Chun, Jong-hwa

    2013-04-01

    For the baseline study in the monitoring gas hydrate test production in the Ulleung Basin, Korea Institute of Geoscience and Mineral Resources (KIGAM) has developed the KIGAM Seafloor Observation System (KISOS) for seafloor exploration using unmanned remotely operated vehicle connected with a ship by a cable. The KISOS consists of a transponder of an acoustic positioning system (USBL), a bottom finding pinger, still camera, video camera, water sampler, and measuring devices (methane, oxygen, CTD, and turbidity sensors) mounted on the unmanned ROV, and a sediment collecting device collecting sediment on the seafloor. It is very important to monitoring the environmental risks (gas leakage and production water/drilling mud discharge) which may be occurred during the gas hydrate test production drilling. The KISOS will be applied to solely conduct baseline study with the KIGAM seafloor monitoring system (KIMOS) of the Korean gas hydrate program in the future. The large scale of environmental monitoring program includes the environmental impact assessment such as seafloor disturbance and subsidence, detection of methane gas leakage around well and cold seep, methane bubbles and dissolved methane, change of marine environments, chemical factor variation of water column and seabed, diffusion of drilling mud and production water, and biological factors of biodiversity and marine habitats before and after drilling test well and nearby areas. The design of the baseline survey will be determined based on the result of SIMAP simulation in 2013. The baseline survey will be performed to provide the gas leakage and production water/drilling mud discharge before and after gas hydrate test production. The field data of the baseline study will be evaluated by the simulation and verification of SIMAP simulator in 2014. In the presentation, the authors would like introduce the configuration of KISOS and applicability to the seafloor observation for the gas hydrate test production in

  8. Removable splint with locking attachments for maxillary distraction osteogenesis with the RED system.

    Science.gov (United States)

    Suzuki, E Y; Suzuki, B

    2007-12-01

    The external traction hooks of the intraoral splint used to control traction forces applied to the maxilla with the rigid external distraction system represent a major barrier to surgical procedures. The purpose of this article is to introduce a removable intraoral splint with locking attachments that can be placed post-surgically immediately before distraction, facilitating surgery and consequently reducing the operative time. Fifteen cleft lip and palate patients underwent maxillary distraction osteogenesis using a rigid external distraction device in combination with the proposed removable splint that was fixed onto the maxillary teeth to provide anchorage. Initial records showed severe maxillary hypoplasia and negative overjet. The removable splint was fabricated using 1.5-mm diameter stainless-steel rigid orthodontic wires soldered to the locking attachments (Y&B Products LP, Chiang Mai, Thailand), making possible its placement post-surgically. Stable splint fixation was achieved prior to the distraction procedure and the desired treatment goals were reached. No complications inserting or removing the splint post-surgically, including pain or discomfort, were observed. The use of the removable splint with locking attachments has proved to be a highly effective fixation approach to manage the severely hypoplastic maxilla, eliminating lip constraints resulting from scarring, and allowing for easier, more deliberate and careful dissection.

  9. CLASSIFICATION OF SYSTEMS FOR PASSIVE AFTERHEAT REMOVAL FROM REACTOR CONTAINMENT OF NUCLEAR POWER PLANT WITH WATER-COOLED POWER REACTOR

    Directory of Open Access Journals (Sweden)

    N. Khaled

    2014-01-01

    Full Text Available A classification on systems for passive afterheat removal from reactor containment has been developed in the paper.  The classification permits to make a detailed analysis of various concepts pertaining to systems for passive afterheat removal from reactor containment of new generation. The paper considers main classification features of the given systems.

  10. Program Baseline Change Control Procedure

    International Nuclear Information System (INIS)

    1993-02-01

    This procedure establishes the responsibilities and process for approving initial issues of and changes to the technical, cost, and schedule baselines, and selected management documents developed by the Office of Civilian Radioactive Waste Management (OCRWM) for the Civilian Radioactive Waste Management System. This procedure implements the OCRWM Baseline Management Plan and DOE Order 4700.1, Chg 1. It streamlines the change control process to enhance integration, accountability, and traceability of Level 0 and Level I decisions through standardized Baseline Change Proposal (BCP) forms to be used by the Level 0, 1, 2, and 3 Baseline Change Control Boards (BCCBs) and to be tracked in the OCRWM-wide Configuration Information System (CIS) Database.This procedure applies to all technical, cost, and schedule baselines controlled by the Energy System Acquisition Advisory Board (ESAAB) BCCB (Level 0) and, OCRWM Program Baseline Control Board (PBCCB) (Level 1). All baseline BCPs initiated by Level 2 or lower BCCBs, which require approval from ESAAB or PBCCB, shall be processed in accordance with this procedure. This procedure also applies to all Program-level management documents controlled by the OCRWM PBCCB

  11. Contaminant removal and hydraulic conductivity of laboratory rain garden systems for stormwater treatment.

    Science.gov (United States)

    Good, J F; O'Sullivan, A D; Wicke, D; Cochrane, T A

    2012-01-01

    In order to evaluate the influence of substrate composition on stormwater treatment and hydraulic effectiveness, mesocosm-scale (180 L, 0.17 m(2)) laboratory rain gardens were established. Saturated (constant head) hydraulic conductivity was determined before and after contaminant (Cu, Zn, Pb and nutrients) removal experiments on three rain garden systems with various proportions of organic topsoil. The system with only topsoil had the lowest saturated hydraulic conductivity (160-164 mm/h) and poorest metal removal efficiency (Cu ≤ 69.0% and Zn ≤ 71.4%). Systems with sand and a sand-topsoil mix demonstrated good metal removal (Cu up to 83.3%, Zn up to 94.5%, Pb up to 97.3%) with adequate hydraulic conductivity (sand: 800-805 mm/h, sand-topsoil: 290-302 mm/h). Total metal amounts in the effluent were pH was elevated (up to 7.38) provided by the calcareous sand in two of the systems, whereas the topsoil-only system lacked an alkaline source. Organic topsoil, a typical component in rain garden systems, influenced pH, resulting in poorer treatment due to higher dissolved metal fractions.

  12. Removal of CO2 in closed loop off-gas treatment systems

    International Nuclear Information System (INIS)

    Clemens, M.K.; Nelson, P.A.; Swift, W.M.

    1994-01-01

    A closed loop test system has been installed at Argonne National Laboratory (ANL) to demonstrate off-gas treatment, absorption, and purification systems to be used for incineration and vitrification of hazardous and mixed waste. Closed loop systems can virtually eliminate the potential for release of hazardous or toxic materials to the atmosphere during both normal and upset conditions. In initial tests, a 250,000 Btu/h (75 kW thermal) combustor was operated in an open loop to produce a combustion product gas. The CO 2 in these tests was removed by reaction with a fluidized bed of time to produce CaCO 3 . Subsequently, recirculation system was installed to allow closed loop operation with the addition of oxygen to the recycle stream to support combustion. Commercially marketed technologies for removal of CO 2 can be adapted for use on closed loop incineration systems. The paper also describes the Absorbent Solution Treatment (AST) process, based on modifications to commercially demonstrated gas purification technologies. In this process, a side loop system is added to the main loop for removing CO 2 in scrubbing towers using aqueous-based CO 2 absorbents. The remaining gas is returned to the incinerator with oxygen addition. The absorbent is regenerated by driving off the CO 2 and water vapor, which are released to the atmosphere. Contaminants are either recycled for further treatment or form precipitates which are removed during the purification and regeneration process. There are no direct releases of gases or particulates to the environment. The CO 2 and water vapor go through two changes of state before release, effectively separating these combustion products from contaminants released during incineration. The AST process can accept a wide range of waste streams. The system may be retrofitted to existing Facilities or included in the designs for new installations

  13. Systems thinking in practice: the current status of the six WHO building blocks for health system strengthening in three BHOMA intervention districts of Zambia: a baseline qualitative study.

    Science.gov (United States)

    Mutale, Wilbroad; Bond, Virginia; Mwanamwenge, Margaret Tembo; Mlewa, Susan; Balabanova, Dina; Spicer, Neil; Ayles, Helen

    2013-08-01

    The primary bottleneck to achieving the MDGs in low-income countries is health systems that are too fragile to deliver the volume and quality of services to those in need. Strong and effective health systems are increasingly considered a prerequisite to reducing the disease burden and to achieving the health MDGs. Zambia is one of the countries that are lagging behind in achieving millennium development targets. Several barriers have been identified as hindering the progress towards health related millennium development goals. Designing an intervention that addresses these barriers was crucial and so the Better Health Outcomes through Mentorship (BHOMA) project was designed to address the challenges in the Zambia's MOH using a system wide approach. We applied systems thinking approach to describe the baseline status of the Six WHO building blocks for health system strengthening. A qualitative study was conducted looking at the status of the Six WHO building blocks for health systems strengthening in three BHOMA districts. We conducted Focus group discussions with community members and In-depth Interviews with key informants. Data was analyzed using Nvivo version 9. The study showed that building block specific weaknesses had cross cutting effect in other health system building blocks which is an essential element of systems thinking. Challenges noted in service delivery were linked to human resources, medical supplies, information flow, governance and finance building blocks either directly or indirectly. Several barriers were identified as hindering access to health services by the local communities. These included supply side barriers: Shortage of qualified health workers, bad staff attitude, poor relationships between community and health staff, long waiting time, confidentiality and the gender of health workers. Demand side barriers: Long distance to health facility, cost of transport and cultural practices. Participating communities seemed to lack the capacity

  14. Systems thinking in practice: the current status of the six WHO building blocks for health system strengthening in three BHOMA intervention districts of Zambia: a baseline qualitative study

    Science.gov (United States)

    2013-01-01

    Background The primary bottleneck to achieving the MDGs in low-income countries is health systems that are too fragile to deliver the volume and quality of services to those in need. Strong and effective health systems are increasingly considered a prerequisite to reducing the disease burden and to achieving the health MDGs. Zambia is one of the countries that are lagging behind in achieving millennium development targets. Several barriers have been identified as hindering the progress towards health related millennium development goals. Designing an intervention that addresses these barriers was crucial and so the Better Health Outcomes through Mentorship (BHOMA) project was designed to address the challenges in the Zambia’s MOH using a system wide approach. We applied systems thinking approach to describe the baseline status of the Six WHO building blocks for health system strengthening. Methods A qualitative study was conducted looking at the status of the Six WHO building blocks for health systems strengthening in three BHOMA districts. We conducted Focus group discussions with community members and In-depth Interviews with key informants. Data was analyzed using Nvivo version 9. Results The study showed that building block specific weaknesses had cross cutting effect in other health system building blocks which is an essential element of systems thinking. Challenges noted in service delivery were linked to human resources, medical supplies, information flow, governance and finance building blocks either directly or indirectly. Several barriers were identified as hindering access to health services by the local communities. These included supply side barriers: Shortage of qualified health workers, bad staff attitude, poor relationships between community and health staff, long waiting time, confidentiality and the gender of health workers. Demand side barriers: Long distance to health facility, cost of transport and cultural practices. Participating

  15. Reliability analysis of emergency decay heat removal system of nuclear ship under various accident conditions

    International Nuclear Information System (INIS)

    Matsuoka, Takeshi

    1984-01-01

    A reliability analysis is given for the emergency decay heat removal system of the Nuclear Ship ''Mutsu'' and the emergency sea water cooling system of the Nuclear Ship ''Savannah'', under ten typical nuclear ship accident conditions. Basic event probabilities under these accident conditions are estimated from literature survey. These systems of Mutsu and Savannah have almost the same reliability under the normal condition. The dispersive arrangement of a system is useful to prevent the reduction of the system reliability under the condition of an accident restricted in one room. As for the reliability of these two systems under various accident conditions, it is seen that the configuration and the environmental condition of a system are two main factors which determine the reliability of the system. Furthermore, it was found that, for the evaluation of the effectiveness of safety system of a nuclear ship, it is necessary to evaluate its reliability under various accident conditions. (author)

  16. Recovery of reactor electrical assemblies using differential de-encapsulation to remove dielectric insulation systems

    International Nuclear Information System (INIS)

    Hubrig, J.G.; Hammerstone, E.B.

    1986-01-01

    State-of-the-art de-encapsulation technologies associated with the conventional dielectric insulation systems employed in the construction of electrical coils and power distribution systems do not allow for accurate fatigue/failure analysis or reliable recovery of costly assembly components. Differential de-encapsulation allows for the selective removal of contemporary thermoset resin based insulation systems to allow non-destructive penetration of insulation wall thicknesses to both examine critical areas and recover high performance metallic and non-metallic inserts for remanufacture; significantly reducing replacement costs and reactor downtime. The authors' analysis describes how the availability of engineering data from the selective and non-destructive removal of insulation materials will aid in the evaluation of original manufacture, materials and procedures; enabling redesign to enhance subsequent on line performance. They also discuss why the ability to recover coil and core assemblies for remanufacture will have a major economic impact on reactor management costs

  17. Arsenic removal from water employing a combined system: photooxidation and adsorption.

    Science.gov (United States)

    Lescano, Maia; Zalazar, Cristina; Brandi, Rodolfo

    2015-03-01

    A combined system employing photochemical oxidation (UV/H2O2) and adsorption for arsenic removal from water was designed and evaluated. In this work, a bench-scale photochemical annular reactor was developed being connected alternately to a pair of adsorption columns filled with titanium dioxide (TiO2) and granular ferric hydroxide (GFH). The experiences were performed by varying the relation of As concentration (As (III)/As (V) weight ratio) at constant hydrogen peroxide concentration and incident radiation. Experimental oxidation results were compared with theoretical predictions using an intrinsic kinetic model previously obtained. In addition, the effectiveness of the process was evaluated using a groundwater sample. The mathematical model of the entire system was developed. It could be used as an effective tool for the design and prediction of the behaviour of these types of systems. The combined technology is efficient and promising for arsenic removal to small and medium scale.

  18. Intensified nitrogen and phosphorus removal in a novel electrolysis-integrated tidal flow constructed wetland system.

    Science.gov (United States)

    Ju, Xinxin; Wu, Shubiao; Zhang, Yansheng; Dong, Renjie

    2014-08-01

    A novel electrolysis-integrated tidal flow constructed wetland (CW) system was developed in this study. The dynamics of intensified nitrogen and phosphorus removal and that of hydrogen sulphide control were evaluated. Ammonium removal of up to 80% was achieved with an inflow concentration of 60 mg/L in wetland systems with and without electrolysis integration. Effluent nitrate concentration decreased from 2 mg/L to less than 0.5 mg/L with the decrease in current intensity from 1.5 mA/cm(2) to 0.57 mA/cm(2) in the electrolysis-integrated wetland system, thus indicating that the current intensity of electrolysis plays an important role in nitrogen transformations. Phosphorus removal was significantly enhanced, exceeding 95% in the electrolysis-integrated CW system because of the in-situ formation of a ferric iron coagulant through the electro-dissolution of a sacrificial iron anode. Moreover, the electrolyzed wetland system effectively inhibits sulphide accumulation as a result of a sulphide precipitation coupled with ferrous-iron electro-dissolution and/or an inhibition of bacterial sulphate reduction under increased aerobic conditions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Novel flow-through bioremediation system for removing nitrate from nursery discharge water.

    Science.gov (United States)

    Chris Wilson, P; Albano, Joseph P

    2013-11-30

    Nitrate losses in surface runoff water from nursery production areas can be significant. This study evaluated the potential use of microbial-based (denitrification), flow-through bioreactors for their nitrate-remediation ability. Duplicate bioreactor systems were constructed at a local foliage plant nursery. Each bioreactor system consisted of four 242 L tanks with connections alternating between bottom and top. Each tank was filled with approximately 113 L of Kaldness media to provide surface area for attachment of native microflora. Molasses was supplied as a carbon source for denitrification and water flow rates through the systems ranged from 5 to 18 L min(-1) during tests. Automatic water samplers were used to collect composite samples every 15 min from both the inflow and the exit flow water. Results indicate consistent removal of 80-100% of the nitrate flowing into the systems. Accumulation of ammoniacal and nitrite nitrogen did not occur, indicating that the nitrate-nitrogen was removed from the water, and not simply transformed into another water-soluble species. Occasions where removal rates were less than 80% were usually traced to faulty delivery of the carbon source. Results indicate that modular microbial-based bioremediation systems may be a useful tool for helping water managers meet stringent nitrogen water quality regulations, especially at nurseries with limited space for expansion of water retention facilities. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Removal of nitrogen by a layered soil infiltration system during intermittent storm events.

    Science.gov (United States)

    Cho, Kang Woo; Song, Kyung Guen; Cho, Jin Woo; Kim, Tae Gyun; Ahn, Kyu Hong

    2009-07-01

    The fates of various nitrogen species were investigated in a layered biological infiltration system under an intermittently wetting regime. The layered system consisted of a mulch layer, coarse soil layer (CSL), and fine soil layer (FSL). The effects of soil texture were assessed focusing on the infiltration rate and the removal of inorganic nitrogen species. The infiltration rate drastically decreased when the uniformity coefficient was larger than four. The ammonium in the synthetic runoff was shown to be removed via adsorption during the stormwater dosing and nitrification during subsequent dry days. Stable ammonium adsorption was observed when the silt and clay content of CSL was greater than 3%. This study revealed that the nitrate leaching was caused by nitrification during dry days. Various patterns of nitrate flushing were observed depending on the soil configuration. The washout of nitrate was more severe as the silt/clay content of the CSL was greater. However, proper layering of soil proved to enhance the nitrate removal. Consequently, a strictly sandy CSL over FSL with a silt and clay content of 10% was the best configuration for the removal of ammonium and nitrate.

  1. An efficient venturi scrubber system to remove submicron particles in exhaust gas.

    Science.gov (United States)

    Tsai, Chuen-Jinn; Lin, Chia-Hung; Wang, Yu-Min; Hunag, Cheng-Hsiung; Li, Shou-Nan; Wu, Zong-Xue; Wang, Feng-Cai

    2005-03-01

    An efficient venturi scrubber system making use of heterogeneous nucleation and condensational growth of particles was designed and tested to remove fine particles from the exhaust of a local scrubber where residual SiH4 gas was abated and lots of fine SiO2 particles were generated. In front of the venturi scrubber, normal-temperature fine-water mist mixes with high-temperature exhaust gas to cool it to the saturation temperature, allowing submicron particles to grow into micron sizes. The grown particles are then scrubbed efficiently in the venturi scrubber. Test results show that the present venturi scrubber system is effective for removing submicron particles. For SiO2 particles greater than 0.1microm, the removal efficiency is greater than 80-90%, depending on particle concentration. The corresponding pressure drop is relatively low. For example, the pressure drop of the venturi scrubber is approximately 15.4 +/- 2.4 cm H2O when the liquid-to-gas ratio is 1.50 L/m3. A theoretical calculation has been conducted to simulate particle growth process and the removal efficiency of the venturi scrubber. The theoretical results agree with the experimental data reasonably well when SiO2 particle diameter is greater than 0.1 microm.

  2. Assessment of the advantages of a residual heat removal system inside the reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Gautier, G.M. [Commissariat a l`Energie Atomique, Saint-Paul-Lez-Durance (France)

    1995-09-01

    In the framework of research on diversified means for removing residual heat from pressurized water reactors, the CEA is studying a passive system called RRP (Refroidissement du Reacteur au Primaire, or primary circuit cooling system). This system consists of integrated heat-exchangers and a layout of the internal structures so as to obtain convection from the primary circuit inside the vessel, whatever the state of the loops. This system is operational for all primary circuit temperatures and pressures, as well as for a wide range of conditions: such as independent from the state of the loops, low volume of water in the primary circuit, compatibility with either a passive or an active operation mode, and compatibility with any other decay heat removal systems. This paper presents an evaluation of the performance of the RRP system in the event of a small primary circuit break in a totally passive operation mode without the intervention of any another system. The results of this evaluation show the potential interest of such a system: a clear increase of the time-delay for the implementation of a low pressure safety injection system and no need for the use of a high pressure safety injection system.

  3. Optimization of arsenic removal water treatment system through characterization of terminal electron accepting processes.

    Science.gov (United States)

    Upadhyaya, Giridhar; Clancy, Tara M; Brown, Jess; Hayes, Kim F; Raskin, Lutgarde

    2012-11-06

    Terminal electron accepting process (TEAP) zones developed when a simulated groundwater containing dissolved oxygen (DO), nitrate, arsenate, and sulfate was treated in a fixed-bed bioreactor system consisting of two reactors (reactors A and B) in series. When the reactors were operated with an empty bed contact time (EBCT) of 20 min each, DO-, nitrate-, sulfate-, and arsenate-reducing TEAP zones were located within reactor A. As a consequence, sulfate reduction and subsequent arsenic removal through arsenic sulfide precipitation and/or arsenic adsorption on or coprecipitation with iron sulfides occurred in reactor A. This resulted in the removal of arsenic-laden solids during backwashing of reactor A. To minimize this by shifting the sulfate-reducing zone to reactor B, the EBCT of reactor A was sequentially lowered from 20 min to 15, 10, and 7 min. While 50 mg/L (0.81 mM) nitrate was completely removed at all EBCTs, more than 90% of 300 μg/L (4 μM) arsenic was removed with the total EBCT as low as 27 min. Sulfate- and arsenate-reducing bacteria were identified throughout the system through clone libraries and quantitative PCR targeting the 16S rRNA, dissimilatory (bi)sulfite reductase (dsrAB), and dissimilatory arsenate reductase (arrA) genes. Results of reverse transcriptase (RT) qPCR of partial dsrAB (i.e., dsrA) and arrA transcripts corresponded with system performance. The RT qPCR results indicated colocation of sulfate- and arsenate-reducing activities, in the presence of iron(II), suggesting their importance in arsenic removal.

  4. BOA: Asbestos pipe-insulation removal robot system. Phase I. Topical report, November 1993--December 1994

    International Nuclear Information System (INIS)

    Schempf, H.; Bares, J.E.

    1995-01-01

    Based on several key design criteria and site visits, we developed a Robot design and built a system which automatically strips the lagging and insulation from the pipes, and encapsulates them under complete vacuum operation. The system can operate on straight runs of piping in horizontal or vertical orientations. Currently we are limited to four-inch diameter piping without obstacles as well as a somewhat laborious emplacement and removal procedure. Experimental results indicated that the current robotic abatement process is sound yet needs to be further expanded and modified. One of the main discoveries was that a longitudinal cut to fully allow the paddles to dig in and compress the insulation off the pipe is essential. Furthermore, a different cutting method might be explored to alleviate the need for a deeper cut and to enable a combination of certain functions such as compression and cutting. Unfortunately due to a damaged mechanism caused by extensive testing, we were unable to perform vertical piping abatement experiments, but foresee no trouble in implementing them in the next proposed Phase. Other encouraging results have BOA removing asbestos at a rate of 4-5 ft./h compared to 3 ft./h for manual removal of asbestos with a 3-person crew. However, we feel confident that we can double the asbestos removal rate by improving cutting speed, and increasing the length of the BOA robot. The containment and vacuum system on BOA is able to achieve the regulatory requirement for airborne fiber emissions of 0.01 fibers/ccm/8-hr. shift. Currently, BOA weighs about 117 pounds which is more than a human is permitted to lift overhead under OSHA requirements (i.e., 25 pounds). We are considering designing the robot into two components (i.e., locomotor section and cutter/removal section) to aid human installation as well as incorporating composite materials. A more detailed list of all the technical modifications is given in this topical report

  5. BOA: Asbestos pipe-insulation removal robot system. Phase I. Topical report, November 1993--December 1994

    Energy Technology Data Exchange (ETDEWEB)

    Schempf, H.; Bares, J.E.

    1995-01-01

    Based on several key design criteria and site visits, we developed a Robot design and built a system which automatically strips the lagging and insulation from the pipes, and encapsulates them under complete vacuum operation. The system can operate on straight runs of piping in horizontal or vertical orientations. Currently we are limited to four-inch diameter piping without obstacles as well as a somewhat laborious emplacement and removal procedure. Experimental results indicated that the current robotic abatement process is sound yet needs to be further expanded and modified. One of the main discoveries was that a longitudinal cut to fully allow the paddles to dig in and compress the insulation off the pipe is essential. Furthermore, a different cutting method might be explored to alleviate the need for a deeper cut and to enable a combination of certain functions such as compression and cutting. Unfortunately due to a damaged mechanism caused by extensive testing, we were unable to perform vertical piping abatement experiments, but foresee no trouble in implementing them in the next proposed Phase. Other encouraging results have BOA removing asbestos at a rate of 4-5 ft./h compared to 3 ft./h for manual removal of asbestos with a 3-person crew. However, we feel confident that we can double the asbestos removal rate by improving cutting speed, and increasing the length of the BOA robot. The containment and vacuum system on BOA is able to achieve the regulatory requirement for airborne fiber emissions of 0.01 fibers/ccm/8-hr. shift. Currently, BOA weighs about 117 pounds which is more than a human is permitted to lift overhead under OSHA requirements (i.e., 25 pounds). We are considering designing the robot into two components (i.e., locomotor section and cutter/removal section) to aid human installation as well as incorporating composite materials. A more detailed list of all the technical modifications is given in this topical report.

  6. Removal of heavy metals from fly ash leachate using combined bioelectrochemical systems and electrolysis

    International Nuclear Information System (INIS)

    Tao, Hu-Chun; Lei, Tao; Shi, Gang; Sun, Xiao-Nan; Wei, Xue-Yan; Zhang, Li-Juan; Wu, Wei-Min

    2014-01-01

    Highlights: • Heavy metals removal from MSWI fly ash with BES and electrolysis was confirmed. • 98.5% of Cu(II), 95.4% of Zn(II) and 98.1% of Pb(II) removal were achieved in reactors. • BESs can remove some heavy metals in fly ash with energy saving. -- Abstract: Based on environmental and energetic analysis, a novel combined approach using bioelectrochemical systems (BES) followed by electrolysis reactors (ER) was tested for heavy metals removal from fly ash leachate, which contained high detectable levels of Zn, Pb and Cu according to X-ray diffraction analysis. Acetic acid was used as the fly ash leaching agent and tested under various leaching conditions. A favorable condition for the leaching process was identified to be liquid/solid ratio of 14:1 (w/w) and leaching duration 10 h at initial pH 1.0. It was confirmed that the removal of heavy metals from fly ash leachate with the combination of BESs and ER is feasible. The metal removal efficiency was achieved at 98.5%, 95.4% and 98.1% for Cu(II), Zn(II), and Pb(II), respectively. Results of scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) indicated that Cu(II) was reduced and recovered mainly as metal Cu on cathodes related to power production, while Zn(II) and Pb(II) were not spontaneously reduced in BESs without applied voltage and basically electrolyzed in the electrolysis reactors

  7. Retrieval system for emplaced spent unreprocessed fuel (SURF) in salt bed depository. Baseline concept criteria specifications and mechanical failure probabilities

    International Nuclear Information System (INIS)

    Hudson, E.E.; McCleery, J.E.

    1979-05-01

    One of the integral elements of the Nuclear Waste Management Program is the material handling task of retrieving Canisters containing spent unreprocessed fuel from their emplacement in a deep geologic salt bed Depository. A study of the retrieval concept data base predicated this report. In this report, alternative concepts for the tasks are illustrated and critiqued, a baseline concept in scenario form is derived and basic retrieval subsystem specifications are presented with cyclic failure probabilities predicted. The report is based on the following assumptions: (a) during retrieval, a temporary radiation seal is placed over each Canister emplacement; (b) a sleeve, surrounding the Canister, was initially installed during the original emplacement; (c) the emplacement room's physical and environmental conditions established in this report are maintained while the task is performed

  8. Intrafractional Baseline Shift or Drift of Lung Tumor Motion During Gated Radiation Therapy With a Real-Time Tumor-Tracking System

    International Nuclear Information System (INIS)

    Takao, Seishin; Miyamoto, Naoki; Matsuura, Taeko; Onimaru, Rikiya; Katoh, Norio; Inoue, Tetsuya; Sutherland, Kenneth Lee; Suzuki, Ryusuke; Shirato, Hiroki; Shimizu, Shinichi

    2016-01-01

    Purpose: To investigate the frequency and amplitude of baseline shift or drift (shift/drift) of lung tumors in stereotactic body radiation therapy (SBRT), using a real-time tumor-tracking radiation therapy (RTRT) system. Methods and Materials: Sixty-eight patients with peripheral lung tumors were treated with SBRT using the RTRT system. One of the fiducial markers implanted near the tumor was used for the real-time monitoring of the intrafractional tumor motion every 0.033 seconds by the RTRT system. When baseline shift/drift is determined by the system, the position of the treatment couch is adjusted to compensate for the shift/drift. Therefore, the changes in the couch position correspond to the baseline shift/drift in the tumor motion. The frequency and amount of adjustment to the couch positions in the left-right (LR), cranio-caudal (CC), and antero-posterior (AP) directions have been analyzed for 335 fractions administered to 68 patients. Results: The average change in position of the treatment couch during the treatment time was 0.45 ± 2.23 mm (mean ± standard deviation), −1.65 ± 5.95 mm, and 1.50 ± 2.54 mm in the LR, CC, and AP directions, respectively. Overall the baseline shift/drift occurs toward the cranial and posterior directions. The incidence of baseline shift/drift exceeding 3 mm was 6.0%, 15.5%, 14.0%, and 42.1% for the LR, CC, AP, and for the square-root of sum of 3 directions, respectively, within 10 minutes of the start of treatment, and 23.0%, 37.6%, 32.5%, and 71.6% within 30 minutes. Conclusions: Real-time monitoring and frequent adjustments of the couch position and/or adding appropriate margins are suggested to be essential to compensate for possible underdosages due to baseline shift/drift in SBRT for lung cancers.

  9. Oscillation Baselining and Analysis Tool

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-27

    PNNL developed a new tool for oscillation analysis and baselining. This tool has been developed under a new DOE Grid Modernization Laboratory Consortium (GMLC) Project (GM0072 - “Suite of open-source applications and models for advanced synchrophasor analysis”) and it is based on the open platform for PMU analysis. The Oscillation Baselining and Analysis Tool (OBAT) performs the oscillation analysis and identifies modes of oscillations (frequency, damping, energy, and shape). The tool also does oscillation event baselining (fining correlation between oscillations characteristics and system operating conditions).

  10. The protected areas system in Brazil as a baseline condition for wetlands management and fish conservancy: the example of the Pantanal National Park

    OpenAIRE

    Carla N. M. Polaz; Fabio C. Ferreira; Miguel Petrere Júnior

    2017-01-01

    ABSTRACT Considering the need for the Brazilian government to develop tools for environmental monitoring for biodiversity conservancy purposes in the national protected areas system, this paper focuses on determining reference site metrics (or baselines) for adapting the Index of Biotic Integrity (IBI) based on the fish assemblages in the Pantanal National Park (PNP). The habitats in the PNP were grouped into four categories: main rivers, corixos (channels connecting the floodplain), permanen...

  11. Assessment of the advantages of a residual heat removal system inside the reactor pressure vessel

    International Nuclear Information System (INIS)

    Gautier, G.M.

    1995-01-01

    In the framework of research on diversified means for removing the residual heat from pressurized water reactors, the CEA is studying a passive system called RRP (Refroidissement du Reacteur au Primaire, or primary circuit cooling system), which includes integrated heat-exchangers and a layout of the internal structures so as to obtain convection from the primary circuit inside the vessel, whatever the state of the loops. This system is operational for all primary circuit temperatures and pressures, as well as for a wide range of conditions: it is independent of the state of the loops, even if the volume of water in the primary circuit is small, it is compatible with either a passive or an active operation mode, and compatible with any other decay heat removal systems. An evaluation is presented here of the performance of the RRP system in the event of a small primary circuit break in a totally passive operation mode without the intervention of another system. The results of this evaluation show the interest of such a system: a clear increase of the time-delay for the implementation of a low pressure safety injection system, no need for the use of a high pressure safety injection system. (author). 4 refs., 7 figs., 1 tab

  12. Research on How to Remove Efficiently the Condensate Water of Sampling System

    International Nuclear Information System (INIS)

    Cho, SungHwan; Kim, MinSoo; Choi, HoYoung; In, WonHo

    2015-01-01

    Corrosion was caused in the measurement chamber inside the O 2 and H 2 analyzer, and thus measuring the concentration of O 2 and H 2 was not possible. It was confirmed that the cause of the occurrence of condensate water is due to the temperature difference caused during the process of the internal gas of the disposal and degasifier tank being brought into the analyzer. Thus, a heating system was installed inside and outside of the sampling panel for gas to remove generated condensate water in the analyzer and pipe. For the case where condensate water is not removed by the heating system, drain port is also installed in the sampling panel for gas to collect the condensate water of the sampling system. It was verified that there is a great volume of condensate water existing in the pipe line during the purging process after installing manufactured goods. The condensate water was fully removed by the installed heating cable and drain port. The heating cable was operated constantly at a temperature of 80 to 90 .deg. C, which allows the precise measurement of gas concentration and longer maintenance duration by blocking of the condensate water before being produced. To install instruments for measuring the gas, such as an O 2 and H 2 analyzer etc., consideration regarding whether there condensate water is present due to the temperature difference between the measuring system and analyzer is required

  13. Research on How to Remove Efficiently the Condensate Water of Sampling System

    Energy Technology Data Exchange (ETDEWEB)

    Cho, SungHwan; Kim, MinSoo; Choi, HoYoung; In, WonHo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Corrosion was caused in the measurement chamber inside the O{sub 2} and H{sub 2} analyzer, and thus measuring the concentration of O{sub 2} and H{sub 2} was not possible. It was confirmed that the cause of the occurrence of condensate water is due to the temperature difference caused during the process of the internal gas of the disposal and degasifier tank being brought into the analyzer. Thus, a heating system was installed inside and outside of the sampling panel for gas to remove generated condensate water in the analyzer and pipe. For the case where condensate water is not removed by the heating system, drain port is also installed in the sampling panel for gas to collect the condensate water of the sampling system. It was verified that there is a great volume of condensate water existing in the pipe line during the purging process after installing manufactured goods. The condensate water was fully removed by the installed heating cable and drain port. The heating cable was operated constantly at a temperature of 80 to 90 .deg. C, which allows the precise measurement of gas concentration and longer maintenance duration by blocking of the condensate water before being produced. To install instruments for measuring the gas, such as an O{sub 2} and H{sub 2} analyzer etc., consideration regarding whether there condensate water is present due to the temperature difference between the measuring system and analyzer is required.

  14. Nuclear reactor with makeup water assist from residual heat removal system

    International Nuclear Information System (INIS)

    Schulz, T.L.; Corletti, M.M.

    1994-01-01

    A pressurized water nuclear reactor uses its residual heat removal system to make up water in the reactor coolant circuit by pumping water from an in-containment refueling water storage tank during staged depressurization of the coolant circuit, the final stage including passive emergency cooling by gravity feed from the refueling water storage tank to the coolant circuit and to flood the containment building. When depressurization commences due to inadvertence or a manageable leak, the residual heat removal system is activated manually and avoids the final stage of depressurization with its flooding of the containment when such action is not necessary, but does not prevent the final stage when it is necessary. A high pressure makeup water storage tank coupled to the reactor coolant circuit holds makeup coolant at the operational pressure of the reactor. The staged depressurization system vents the coolant circuit to the containment, thus reducing the supply of makeup coolant. The level of makeup coolant can be sensed to trigger opening of successive depressurization conduits. The residual heat removal system can also be coupled in a loop with the refueling water supply tanks for cooling the tank. (Author)

  15. Performance of the constructed wetland systems in pollutants removal from hog wastewater

    Directory of Open Access Journals (Sweden)

    Wallison da Silva Freitas

    2010-08-01

    Full Text Available The main objective of this work was to evaluate the efficiency of a constructed wetland systems (CWS for pollutants removal, in mono crop and multi crop with three different species of plants, originated from hog wastewater treatment (HW. Therefore, 5 CWS of 24.0 m x 1.1 m x 0.7 m were constructed, sealed with a membrane of polyvinyl chloride (PVC and filled with 0.4 m of small gravel. In CWS1, CWS2 and CWS3 grown to cattail (Typha latifolia L., Alternanthera philoxeroides (Mart. Griseb. and Tifton 85 grass (Cynodon dactylon Pers., respectively. In the bed of CWS4 was planted at 1st third Alternanthera, cattail, in the 2nd third and tifton-85 grass and in the 3rd third of. The CWS5 was not planted and it was used as control. After passing through a filter filled with crushed bagasse of sugar cane, the HW was applied to the CWS in a flow of 0.8 m3 d-1, which corresponded to a hydraulic detention time of 4.8 days. According to the results it was shown that the five CWS(s had statistically nearly the same removal of pollutants, and the average removal efficiency of TSS, COD, BOD and Zn, were 91, 89, 86 and 94%, respectively. Also high removals were obtained concerning the ST, N-total, NH4+ and P-total, with average values of 62, 59, 52 and 50%, respectively. The plants in all planted CWS worked in a similar way maintaining the system efficiency and the non cultivated CWS presented analogous capacity of pollutants removal when compared to the cultivated CWS(s.

  16. PANDA experiment and International Standard Problem for passive cooling systems for afterheat removal

    International Nuclear Information System (INIS)

    Yadigaroglu, G.; Aksan, N.S.

    1999-01-01

    In the context of OECD/NEA, Paul Scherrer Institut (PSI) is working on an International Standard Problem which is to provide information on the efficiency and use of computer program systems for passive afterheat removal systems. The PANDA test facility of PSI was designed for these investigations. A six-phase PANDA experiment provides a basis for pre-calculation and recalculation of selected phases covering a limited number of system-typical operating states and phenomena. The experiment was specified and carried out in the year under report [de

  17. Application of vascular aquatic plants for pollution removal, energy and food production in a biological system

    Science.gov (United States)

    Wolverton, B. C.; Barlow, R. M.; Mcdonald, R. C.

    1975-01-01

    Vascular aquatic plants such as water hyacinths (Eichhornia crassipes) (Mart.) Solms and alligator weeds (Alternanthera philoxeroides) (Mart.) Griesb., when utilized in a controlled biological system (including a regular program of harvesting to achieve maximum growth and pollution removal efficiency), may represent a remarkably efficient and inexpensive filtration and disposal system for toxic materials and sewage released into waters near urban and industrial areas. The harvested and processed plant materials are sources of energy, fertilizer, animal feed, and human food. Such a system has industrial, municipal, and agricultural applications.

  18. Failure Modes and Effects Analysis (FMEA) of the Residual Heat Removal System

    International Nuclear Information System (INIS)

    Eggleston, F.T.

    1976-01-01

    The Residual Heat Removal System (RHRS) transfer heat from the Reactor Coolant System (RCS) to the reactor plant Component Cooling System (CCS) to reduce the temperature of the RCS at a controlled rate during the second part of normal plant cooldown and maintains the desired temperature until the plant is restarted. By the use of an analytic tool, the Failure Modes and Effects Analysis, it is shown that the RHRS, because of its redundant two train design, is able to accommodate any credible component single failure with the only effect being an extension in the required cooldown time, thus demonstrating the reliability of the RHRS to perform its intended function

  19. Evaporation and condensation devices for passive heat removal systems in nuclear power engineering

    International Nuclear Information System (INIS)

    Gershuni, A.N.; Pis'mennyj, E.N.; Nishchik, A.P.

    2016-01-01

    The paper justifies advantages of evaporation and condensation heat transfer devices as means of passive heat removal and thermal shielding in nuclear power engineering. The main thermophysical factors that limit heat transfer capacity of evaporation and condensation systems have been examined in the research. The results of experimental studies of heat engineering properties of elongated (8-m) vertically oriented evaporation and condensation devices (two-phase thermosyphons), which showed a high enough heat transfer capacity, as well as stability and reliability both in steady state and in start-up modes, are provided. The paper presents the examples of schematic designs of evaporation and condensation systems for passive heat removal and thermal shielding in application to nuclear power equipment

  20. A design assessment of tritium removal systems for the mirror advanced reactor study

    International Nuclear Information System (INIS)

    Sood, S.K.; Kveton, O.K.

    1983-01-01

    This study investigates the available processes for removing tritium from light water, and selects the most appropriate process for recovering tritium from the various tritiated water streams identified in the Mirror Advanced Reactor Study (MARS). A simplified flowsheet is shown for the process and the main process parameters are identified. Previous experience is utilized to predict direct capital costs and power requirement for the Tritiated Water Removal Unit (TWRU). A number of possibilities are discussed for lowering the cost of the TWRU. An estimate is made of the direct capital cost for the Air Detritiation System that has already been selected as the reference design by MARS personnel. The leakage from the MARS coolant loop is estimated, based on the experience obtained with Ontario Hydro's coolant systems. Design targets are identified for tritium levels in the reactor hall atmosphere and in water and air emissions. Tritium levels are predicted for these and are assessed against the previously identified targets

  1. Performance improvement of the finned passive PVT system using reflectors like removable insulation covers

    International Nuclear Information System (INIS)

    Ziapour, Behrooz M.; Palideh, Vahid; Mokhtari, Farhad

    2016-01-01

    Highlights: • A passive PVT system means the combination of a PV panel and a compact solar water heater. • Comparative study was done on performance characteristics in passive and hybrid PVT systems. • Reflectors effects on performance of a finned passive PVT system were numerically studied. • Results show that the finned passive PVT system has higher performance than the hybrid type. • Reflectors reduce the night heat losses and increase the solar radiation rate on PVT system. - Abstract: A passive photovoltaic–thermal system (PVT) is the combination of a photovoltaic (PV) panel and a compact solar water heater for co-generation of heat and electricity. This system bears considerable heat losses to ambient, particularly at noncollection times. One simple way to overcome this problem is to use a removable insulation cover on the collector's outer glazing. In this paper, the effects of the reflectors on day and night performance of a finned passive PVT system were numerically studied. At nonenergy collection time, the reflectors can turn and cover the collector cover glass as a nonconductor material. Simulation results showed that the reflectors reduce the night heat losses and increase the solar radiation rate on the absorber plate. The use of removable insulation reflectors resulted to saving extra sensibly thermal energy. Also, the solar cells power generation (P_s_c), in the case of reflectors installed, was reinforced.

  2. Bimetallic Porous Iron (pFe) Materials for Remediation/Removal of Tc from Aqueous Systems

    Energy Technology Data Exchange (ETDEWEB)

    Li, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-09-29

    Remediation of Tc remains an unresolved challenge at SRS and other DOE sites. The objective of this project was to develop novel bimetallic porous iron (pFe) materials for Tc removal from aqueous systems. We showed that the pFe is much more effective in removing TcO4 - (×30) and ReO4 - (×8) from artificial groundwater than granular iron. Tc K-edge XANES spectroscopy indicated that Tc speciation on the pFe was 18% adsorbed TcO4 -, 28% Tc(IV) in Tc dioxide and 54% Tc(IV) into the structure of Fe hydroxide. A variety of catalytic metal nanoparticles (i.e., Ni, Cu, Zn, Ag, Sn and Pd) were successfully deposited on the pFe using scalable chemical reduction methods. The Zn-pFe was outstanding among the six bimetallic pFe materials, with a capacity increase of >100% for TcO4 - removal and of 50% for ReO4 - removal, compared to the pFe. These results provide a highly applicable platform for solving critical DOE and industrial needs related to nuclear environmental stewardship and nuclear power production.

  3. Simultaneous removal of organic matter and salt ions from saline wastewater in bioelectrochemical systems

    KAUST Repository

    Kim, Younggy

    2013-01-01

    A new bioelectrochemical system is proposed for simultaneous removal of salinity and organic matter. In this process, exoelectrogenic microorganisms oxidize organic matter and transfer electrons to the anode, hydrogen is evolved at the cathode by supplying additional voltage, and salt is removed from the wastewater due to the electric potential generated and the use of two ion-exchange membranes. Salinity removal (initial conductivity ~40mS/cm) increased from 21 to 84% by increasing the substrate (sodium acetate) from 2 to 8g/L. A total of 72-94% of the chemical oxygen demand was degraded in the anode and cathode chambers, with 1-4% left in the anode chamber and the balance lost through the anion-exchange membrane into the concentrate waste chamber. The maximum hydrogen production rate was 3.6m3-H2/m3-electrolyte per day at an applied potential of 1.2V. The Coulombic efficiency was ~100%, while the cathode recovery varied from 57 to 100%, depending on the extent of methanogenesis. Exoelectrogenic microbes generated high current densities (7.8mA/cm2) at ≤36g/L of total dissolved solids, but >41g/L eliminated current. These results provide a new method for achieving simultaneous removal of salinity and organic matter from a saline wastewater with H2 production. © 2012 Elsevier B.V.

  4. Nuclear reactor equipped with a flooding tank and a residual heat removal and emergency cooling system

    International Nuclear Information System (INIS)

    Schabert, H.P.; Winkler, F.

    1975-01-01

    A description is given of a nuclear reactor such as a pressurized-water reactor or the like which is equipped with a flooding tank and a residual heat removal and emergency cooling system. The flooding tank is arranged within the containment shell at an elevation above the upper edge of the reactor core and contains a liquid for flooding the reactor core in the event of a loss of coolant

  5. Experience on the removal of impurities from liquid metal systems by cold-trapping

    Energy Technology Data Exchange (ETDEWEB)

    Bray, J. A.

    1963-10-15

    Experience in impurity removal by cold-trapping, which was obtained on DFR and its associated liquid metal rigs, is reviewed. The development of the present DFR cold-trapping system is outlined, and the operation of the additional pumped loops, which were required in order to control the reactor impurity levels, are described. Operation of the liquid metal rigs ancillary to the reactor project is discussed with particular reference to the control of impurity levels. (auth)

  6. Assessment of full-scale biological nutrient removal systems upgraded with physico-chemical processes for the removal of emerging pollutants present in wastewaters from Mexico.

    Science.gov (United States)

    Estrada-Arriaga, Edson Baltazar; Cortés-Muñoz, Juana Enriqueta; González-Herrera, Arturo; Calderón-Mólgora, César Guillermo; de Lourdes Rivera-Huerta, Ma; Ramírez-Camperos, Esperanza; Montellano-Palacios, Leticia; Gelover-Santiago, Silvia Lucila; Pérez-Castrejón, Sara; Cardoso-Vigueros, Lina; Martín-Domínguez, Alejandra; García-Sánchez, Liliana

    2016-11-15

    Two full-scale biological nutrient removal systems upgraded with three physico-chemical processes (coagulation, chemical precipitation, and neutral Fenton) were evaluated in order to determine the removal of emerging pollutants (EPs) present in municipal wastewater from Mexico. Between 41 and 55 EPs were detected in the influents of two wastewater treatment plants (WWTPs), including personal care products (PPCPs), antibiotics, analgesics, antiepileptics, antilipidemics, antihypertensives, antiseptics, stimulants, and hormones. Emerging pollutants were detected at concentrations ranging from 0.69ng/L to 94,600ng/L. High concentrations of emerging pollutants were found during dry season. WWTP 1, integrated by oxidation ditches and UV light lamps, showed removal efficiencies of EPs between 20% and 22%. On the other hand, WWTP 2 consisted of anaerobic/anoxic/aerobic tanks coupled with two disinfection processes; chlorine dioxide and UV light lamps, for which the removal of EPs was significant (up to 80%). The concentrations of emerging pollutants in WWTP 1 effluent was found within a rangeemerging pollutants in the effluent were below 210ng/L. WWTP 2 showed high emerging pollutant removals, compared to those of WWTP 1, due to a greater activity of the simultaneous nitrification-denitrification processes, hydraulic retention time, and solids retention time. The compounds that were more persistent with removals below 50% in both effluents were: carbamazepine, dehydronifedipine, meprobamate, sertraline, propranolol, propoxyphene, norverapamil, diazepam, alprazolam, sulfamethoxazole, metoprolol, ofloxacin, norfloxacin, fluoxetine, erythromycin-H2O, diphenhydramine, dehydronifedipine, clarithromycin, hydrochlorothiazide, and albuterol. The application of neutral Fenton reaction as post-treatment for the two effluents from the WWTPs is promising for the removal of emerging pollutants (up to 100%) and for assuring high quality of treated water. Copyright © 2016 Elsevier B

  7. Study of modified two incisions silicone oil removal with a 23G transconjunctival sutureless vitrectomy system

    Directory of Open Access Journals (Sweden)

    Hai-Jun Yang

    2015-01-01

    Full Text Available AIM:To evaluate the efficacy and safety of silicone oil removal with a 23G transconjunctival sutureless vitrectomy system linked disposable transfusion tube and self-made suction tip. METHODS: The suction tip was made with a 23G infusion tube be cut from the end of the 5mm. It was used to connect the disposable transfusion tube and 23G puncture cannula. The disposable transfusion tube which was cut from the end of the MaiFei's pipe was connected with the effusion box of the vitreous cutter. Intraocular silicone oil was proactive suction and removed through two incisions on pars plana ciliaris with the vitreous cutter suction system. RESULTS: Only 13 cases(9.8%need suture puncture ports in 132 cases in the operation. Operation time was 7-28min. The average operation time was 15.1± 6.2min. In early postoperative, there were 107 cases(81.1%appeared lower intraocular pressure(CONCLUSION: The surgery that silicone oil is removed through two incisions with a 23G transconjunctival sutureless vitrectomy system linked disposable transfusion tube and self-made suction tip has the advantages of safe, effective, fast, economic, and it is worthy of popularization and application in clinical.

  8. Numerical investigation of passive heat removal system via steam generator in VVER 1200

    International Nuclear Information System (INIS)

    Dinh Anh Tuan; Duong Thanh Tung; Tran Chi Thanh; Nguyen Van Thai

    2015-01-01

    Passive heat removal system (PHRS) via Steam Generator is an important part in VVER design. In case of Design Basic Accidents such as blackout, failure of feed water supply to steam generator or coolant leakage with failure of emergency core cooling at high pressure. PHRS is designed to remove the residual heat from reactor core through steam generator to heat exchanger which is placed outside reactor vessel. In order to evaluate the passive system, a numerical investigation using a CFD code is performed. However, PHRS has complex geometry for using CFD simulation. Thus, RELAP5 is applied to provide the wall heat flux of tube in the heat exchanger tank. The natural convection in the heat exchanger tank is investigated in this report. Numerical results show temperature and velocity distribution in the heat exchanger tank are calculated with different wall heat flux corresponding to various transient conditions. The calculated results contribute to the capacity analysis of passive heat removal system and giving valuable information for safe operation of VVER 1200. (author)

  9. Removal of triazine herbicides from aqueous systems by a biofilm reactor continuously or intermittently operated.

    Science.gov (United States)

    Sánchez-Sánchez, R; Ahuatzi-Chacón, D; Galíndez-Mayer, J; Ruiz-Ordaz, N; Salmerón-Alcocer, A

    2013-10-15

    The impact of pesticide movement via overland flow or tile drainage water on the quality of receiving water bodies has been a serious concern in the last decades; thus, for remediation of water contaminated with herbicides, bioreaction systems designed to retain biomass have been proposed. In this context, the aim of this study was to evaluate the atrazine and terbutryn biodegradation capacity of a microbial consortium, immobilized in a biofilm reactor (PBR), packed with fragments of porous volcanic stone. The microbial consortium, constituted by four predominant bacterial strains, was used to degrade a commercial formulation of atrazine and terbutryn in the biofilm reactor, intermittently or continuously operated at volumetric loading rates ranging from 44 to 306 mg L(-1) d(-1). The complete removal of both herbicides was achieved in both systems; however, higher volumetric removal rates were obtained in the continuous system. It was demonstrated that the adjuvants of the commercial formulation of the herbicide significantly enhanced the removal of atrazine and terbutryn. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Investigation of Characteristics of Passive Heat Removal System Based on the Assembled Heat Transfer Tube

    Directory of Open Access Journals (Sweden)

    Xiangcheng Wu

    2016-12-01

    Full Text Available To get an insight into the operating characteristics of the passive residual heat removal system of molten salt reactors, a two-phase natural circulation test facility was constructed. The system consists of a boiling loop absorbing the heat from the drain tank, a condensing loop consuming the heat, and a steam drum. A steady-state experiment was carried out, in which the thimble temperature ranged from 450°C to 700°C and the system pressure was controlled at levels below 150 kPa. When reaching a steady state, the system was operated under saturated conditions. Some important parameters, including heat power, system resistance, and water level in the steam drum and water tank were investigated. The experimental results showed that the natural circulation system is feasible in removing the decay heat, even though some fluctuations may occur in the operation. The uneven temperature distribution in the water tank may be inevitable because convection occurs on the outside of the condensing tube besides boiling with decreasing the decay power. The instabilities in the natural circulation loop are sensitive to heat flux and system resistance rather than the water level in the steam drum and water tank. RELAP5 code shows reasonable results compared with experimental data.

  11. Heat removal performance of auxiliary cooling system for the high temperature engineering test reactor during scrams

    International Nuclear Information System (INIS)

    Takeda, Takeshi; Tachibana, Yukio; Iyoku, Tatsuo; Takenaka, Satsuki

    2003-01-01

    The auxiliary cooling system of the high temperature engineering test reactor (HTTR) is employed for heat removal as an engineered safety feature when the reactor scrams in an accident when forced circulation can cool the core. The HTTR is the first high temperature gas-cooled reactor in Japan with reactor outlet gas temperature of 950 degree sign C and thermal power of 30 MW. The auxiliary cooling system should cool the core continuously avoiding excessive cold shock to core graphite components and water boiling of itself. Simulation tests on manual trip from 9 MW operation and on loss of off-site electric power from 15 MW operation were carried out in the rise-to-power test up to 20 MW of the HTTR. Heat removal characteristics of the auxiliary cooling system were examined by the tests. Empirical correlations of overall heat transfer coefficients were acquired for a helium/water heat exchanger and air cooler for the auxiliary cooling system. Temperatures of fluids in the auxiliary cooling system were predicted on a scram event from 30 MW operation at 950 degree sign C of the reactor outlet coolant temperature. Under the predicted helium condition of the auxiliary cooling system, integrity of fuel blocks among the core graphite components was investigated by stress analysis. Evaluation results showed that overcooling to the core graphite components and boiling of water in the auxiliary cooling system should be prevented where open area condition of louvers in the air cooler is the full open

  12. Investigation of characteristics of passive heat removal system based on the assembled heat transfer tube

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Xiang Cheng; Yan, Changqi; Meng, Zhao Ming; Chen, Kailun; Song, Shao Chuang; Yang, Zong Hao; Yu, Jie [Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin (China)

    2016-12-15

    To get an insight into the operating characteristics of the passive residual heat removal system of molten salt reactors, a two-phase natural circulation test facility was constructed. The system consists of a boiling loop absorbing the heat from the drain tank, a condensing loop consuming the heat, and a steam drum. A steady-state experiment was carried out, in which the thimble temperature ranged from 450 .deg. C to 700 .deg. C and the system pressure was controlled at levels below 150 kPa. When reaching a steady state, the system was operated under saturated conditions. Some important parameters, including heat power, system resistance, and water level in the steam drum and water tank were investigated. The experimental results showed that the natural circulation system is feasible in removing the decay heat, even though some fluctuations may occur in the operation. The uneven temperature distribution in the water tank may be inevitable because convection occurs on the outside of the condensing tube besides boiling with decreasing the decay power. The instabilities in the natural circulation loop are sensitive to heat flux and system resistance rather than the water level in the steam drum and water tank. RELAP5 code shows reasonable results compared with experimental data.

  13. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012.

    Science.gov (United States)

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A; Silvestre, Juan F; Sánchez-Pérez, Javier; Weisshaar, Elke; Uter, Wolfgang

    2015-09-01

    Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. Data of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. The 'basic markers' were tested on 51 477 [fragrance mix II (FM II)] to 57 123 [Myroxylon pereirae, balsam of Peru] patients, and yielded positive reactions as follows: fragrance mix I 6.9%, Myroxylon pereirae 5.4%, FM II 3.8%, colophonium 2.6%, and hydroxyisohexyl 3-cyclohexene carboxaldehyde 1.7%, with some regional differences. Prevalences with TRUE Test(®) allergens were lower. Additional fragrances were tested on 3643 (trimethylbenzenepropanol) to 14 071 (oil of turpentine) patients, and yielded between 2.6% (Cananga odorata) and 0.7% (trimethylbenzenepropanol) positive reactions. Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance allergens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Measuring health system strengthening: application of the balanced scorecard approach to rank the baseline performance of three rural districts in Zambia.

    Directory of Open Access Journals (Sweden)

    Wilbroad Mutale

    Full Text Available INTRODUCTION: There is growing interest in health system performance and recently WHO launched a report on health systems strengthening emphasising the need for close monitoring using system-wide approaches. One recent method is the balanced scorecard system. There is limited application of this method in middle- and low-income countries. This paper applies the concept of balanced scorecard to describe the baseline status of three intervention districts in Zambia. METHODOLOGY: The Better Health Outcome through Mentoring and Assessment (BHOMA project is a randomised step-wedged community intervention that aims to strengthen the health system in three districts in the Republic of Zambia. To assess the baseline status of the participating districts we used a modified balanced scorecard approach following the domains highlighted in the MOH 2011 Strategic Plan. RESULTS: Differences in performance were noted by district and residence. Finance and service delivery domains performed poorly in all study districts. The proportion of the health workers receiving training in the past 12 months was lowest in Kafue (58% and highest in Luangwa district (77%. Under service capacity, basic equipment and laboratory capacity scores showed major variation, with Kafue and Luangwa having lower scores when compared to Chongwe. The finance domain showed that Kafue and Chongwe had lower scores (44% and 47% respectively. Regression model showed that children's clinical observation scores were negatively correlated with drug availability (coeff -0.40, p = 0.02. Adult clinical observation scores were positively association with adult service satisfaction score (coeff 0.82, p = 0.04 and service readiness (coeff 0.54, p = 0.03. CONCLUSION: The study applied the balanced scorecard to describe the baseline status of 42 health facilities in three districts of Zambia. Differences in performance were noted by district and residence in most domains with finance and service

  15. Measuring health system strengthening: application of the balanced scorecard approach to rank the baseline performance of three rural districts in Zambia.

    Science.gov (United States)

    Mutale, Wilbroad; Godfrey-Fausset, Peter; Mwanamwenge, Margaret Tembo; Kasese, Nkatya; Chintu, Namwinga; Balabanova, Dina; Spicer, Neil; Ayles, Helen

    2013-01-01

    There is growing interest in health system performance and recently WHO launched a report on health systems strengthening emphasising the need for close monitoring using system-wide approaches. One recent method is the balanced scorecard system. There is limited application of this method in middle- and low-income countries. This paper applies the concept of balanced scorecard to describe the baseline status of three intervention districts in Zambia. The Better Health Outcome through Mentoring and Assessment (BHOMA) project is a randomised step-wedged community intervention that aims to strengthen the health system in three districts in the Republic of Zambia. To assess the baseline status of the participating districts we used a modified balanced scorecard approach following the domains highlighted in the MOH 2011 Strategic Plan. Differences in performance were noted by district and residence. Finance and service delivery domains performed poorly in all study districts. The proportion of the health workers receiving training in the past 12 months was lowest in Kafue (58%) and highest in Luangwa district (77%). Under service capacity, basic equipment and laboratory capacity scores showed major variation, with Kafue and Luangwa having lower scores when compared to Chongwe. The finance domain showed that Kafue and Chongwe had lower scores (44% and 47% respectively). Regression model showed that children's clinical observation scores were negatively correlated with drug availability (coeff -0.40, p = 0.02). Adult clinical observation scores were positively association with adult service satisfaction score (coeff 0.82, p = 0.04) and service readiness (coeff 0.54, p = 0.03). The study applied the balanced scorecard to describe the baseline status of 42 health facilities in three districts of Zambia. Differences in performance were noted by district and residence in most domains with finance and service delivery performing poorly in all study districts. This tool could

  16. Measuring Health System Strengthening: Application of the Balanced Scorecard Approach to Rank the Baseline Performance of Three Rural Districts in Zambia

    Science.gov (United States)

    Mutale, Wilbroad; Godfrey-Fausset, Peter; Mwanamwenge, Margaret Tembo; Kasese, Nkatya; Chintu, Namwinga; Balabanova, Dina; Spicer, Neil; Ayles, Helen

    2013-01-01

    Introduction There is growing interest in health system performance and recently WHO launched a report on health systems strengthening emphasising the need for close monitoring using system-wide approaches. One recent method is the balanced scorecard system. There is limited application of this method in middle- and low-income countries. This paper applies the concept of balanced scorecard to describe the baseline status of three intervention districts in Zambia. Methodology The Better Health Outcome through Mentoring and Assessment (BHOMA) project is a randomised step-wedged community intervention that aims to strengthen the health system in three districts in the Republic of Zambia. To assess the baseline status of the participating districts we used a modified balanced scorecard approach following the domains highlighted in the MOH 2011 Strategic Plan. Results Differences in performance were noted by district and residence. Finance and service delivery domains performed poorly in all study districts. The proportion of the health workers receiving training in the past 12 months was lowest in Kafue (58%) and highest in Luangwa district (77%). Under service capacity, basic equipment and laboratory capacity scores showed major variation, with Kafue and Luangwa having lower scores when compared to Chongwe. The finance domain showed that Kafue and Chongwe had lower scores (44% and 47% respectively). Regression model showed that children's clinical observation scores were negatively correlated with drug availability (coeff −0.40, p = 0.02). Adult clinical observation scores were positively association with adult service satisfaction score (coeff 0.82, p = 0.04) and service readiness (coeff 0.54, p = 0.03). Conclusion The study applied the balanced scorecard to describe the baseline status of 42 health facilities in three districts of Zambia. Differences in performance were noted by district and residence in most domains with finance and service delivery

  17. Micropollutants removal and health risk reduction in a water reclamation and ecological reuse system.

    Science.gov (United States)

    Ma, Xiaoyan Y; Li, Qiyuan; Wang, Xiaochang C; Wang, Yongkun; Wang, Donghong; Ngo, Huu Hao

    2018-07-01

    As reclaimed water use is increasing, its safety attracts growing attention, particularly with respect to the health risks associated with the wide range of micropollutants found in the reclaimed water. In this study, sophisticated analysis was conducted for water samples from a water reclamation and ecological reuse system where domestic wastewater was treated using an anaerobic-anoxic-oxic unit followed by a membrane bioreactor (A 2 O-MBR), and the reclaimed water was used for replenishing a landscape lake. A total of 58 organic micropollutants were detected in the system, consisting of 13 polycyclic aromatic hydrocarbons (PAHs), 16 phenols, 3 pesticides, and 26 pharmaceuticals and personal care products (PPCPs). After treatment by the A 2 O-MBR process, effective removal of pesticides and phenols was achieved, while when the reclaimed water entered the landscape lake, PPCPs were further removed. From the physicochemical properties of micropollutants, it could be inferred that phenols and dichlorphos (the only pesticide with considerable concentration in the influent) would have been mainly removed by biodegradation and/or volatilization in the biological treatment process. Additionally, it is probable that sludge adsorption also contributed to the removal of dichlorphos. For the predominant PPCP removal in the landscape lake, various actions, such as adsorption, biodegradation, photolysis, and ecologically mediated processes (via aquatic plants and animals), would have played significant roles. However, according to their logK oc , logK ow and logD (pH = 8) values, it could be concluded that adsorption by suspended solids might be an important action. Although carcinogenic and non-carcinogenic risks associated with all the detected micropollutants were at negligible levels, the hazard quotients (HQs) of PPCPs accounted for 92.03%-97.23% of the HQ Total . With the significant removal of PPCPs through the ecological processes in the landscape lake, the safety

  18. Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff.

    Science.gov (United States)

    Anderson, Brian S; Phillips, Bryn M; Voorhees, Jennifer P; Cahn, Michael

    2017-05-15

    Urban stormwater and agriculture irrigation runoff contain a complex mixture of contaminants that are often toxic to adjacent receiving waters. Runoff may be treated with simple systems designed to promote sorption of contaminants to vegetation and soils and promote infiltration. Two example systems are described: a bioswale treatment system for urban stormwater treatment, and a vegetated drainage ditch for treating agriculture irrigation runoff. Both have similar attributes that reduce contaminant loading in runoff: vegetation that results in sorption of the contaminants to the soil and plant surfaces, and water infiltration. These systems may also include the integration of granulated activated carbon as a polishing step to remove residual contaminants. Implementation of these systems in agriculture and urban watersheds requires system monitoring to verify treatment efficacy. This includes chemical monitoring for specific contaminants responsible for toxicity. The current paper emphasizes monitoring of current use pesticides since these are responsible for surface water toxicity to aquatic invertebrates.

  19. Safety analysis of increase in heat removal from reactor coolant system with inadvertent operation of passive residual heat removal at no load conditions

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Ge; Cao, Xuewu [School of Mechanical and Engineering, Shanghai Jiao Tong University, Shanghai (China)

    2015-06-15

    The advanced passive pressurized water reactor (PWR) is being constructed in China and the passive residual heat removal (PRHR) system was designed to remove the decay heat. During accident scenarios with increase of heat removal from the primary coolant system, the actuation of the PRHR will enhance the cooldown of the primary coolant system. There is a risk of power excursion during the cooldown of the primary coolant system. Therefore, it is necessary to analyze the thermal hydraulic behavior of the reactor coolant system (RCS) at this condition. The advanced passive PWR model, including major components in the RCS, is built by SCDAP/RELAP5 code. The thermal hydraulic behavior of the core is studied for two typical accident sequences with PRHR actuation to investigate the core cooling capability with conservative assumptions, a main steam line break (MSLB) event and inadvertent opening of a steam generator (SG) safety valve event. The results show that the core is ultimately shut down by the boric acid solution delivered by Core Makeup Tank (CMT) injections. The effects of CMT boric acid concentration and the activation delay time on accident consequences are analyzed for MSLB, which shows that there is no consequential damage to the fuel or reactor coolant system in the selected conditions.

  20. Obliged Removal of the Percutaneous Fixation System on the Thoracolumbar Junction in Patients with Idiopathic Scoliosis

    Directory of Open Access Journals (Sweden)

    Alessandro Landi

    2016-12-01

    Full Text Available Introduction Minimally invasive percutaneous surgery of the spine is used to treat thoracolumbar junction and lumbar spine fractures by percutaneous fixation. Once fusion has been obtained, it is possible to remove the percutaneous instrumentation after 6 - 12 months. We report the case of an obliged removal of the fixation system at 12 months following operation in a patient with a pre-existing compensated and asymptomatic idiopathic scoliosis. Case Presentation A 48-year-old patient affected by a compensated asymptomatic idiopathic scoliosis with an L3 type A3 fracture. The patient underwent a percutaneous short fixation L2 - L4. In the following months the patient presented progressive worsening of the low back pain and walking difficulties. The percutaneous fixation system was then removed using the same surgical access. Conclusions This particular case explains well the importance of biomechanical balance when a spinal fixation should be perform, and demonstrate how an underestimation of this aspect may cause a worsening of symptoms even if the surgical procedure was correctly performed. It is evident that the removal procedure can lead clinical benefit to a patient, in which the fixation system created a decompensation of the curvature of the spine, thus causing biomechanical alterations and generating pain. In these cases, it may be opportune to limit the fracture reduction during the surgical procedure to modify the least possible the pre-existing scoliosis and to increase the patient’s comfort after the operation. The biomechanical behaviour of the spine is specific for each patient so only a careful detection of it could lead to an optimal therapeutic result.

  1. Study of metal removal by square Wetland System with Eleocharis SP. using SR-XRF

    International Nuclear Information System (INIS)

    Avelino Neto, Sebastiao; Moreira, Silvana

    2007-01-01

    The pollution of the water resources for metals, results of different economic activities. The objective of the present study was to use the SR-TXRF technique to evaluate the performance of Wetland system cultivated with Eleocharis sp. installed at FEAGRI-UNICAMP, in the metal removal. The metals analyzed were Cr, Mn, Fe, Zn and Pb. Samples of the wastewater in the exit, Eleocharis sp. leaf and medium boulder were collected during 20 weeks consecutively. The system was operated with different outflows and hydraulic detention times (HDT) as: 600 L.day -1 (HDT 2 days), 400 L.day-1 (HDT 3 days), 300 L.day -1 (HDT 4 days) and 200 L.day -1 (HDT 6 days). The main source of metal removal was medium boulder with efficiency varying 30.1% for Cr and 98.9% for Pb, independent of the hydraulic detention time (HDT) used. The efficiency of the wetland in the Cr removal varied between 39.6 and 98.7%, and for Mn was higher than 81.6%. For Fe the performance was higher than 70.6% and for Cu the efficiency varied between 88.4 and 99.7 %, while for Pb the variation was 67.5 to 98.4 %. The wetland system with Eleocharis sp were in agreement with CONAMA legislation concern to Fe, Cu and Zn removal and for HDT of 2, 3, 4 and 6 days (HDT), moreover for Mn was necessary 4 and 6 days (HDT) and for Cr and Pb 6 days (HDT). (author)

  2. Study of metal removal by square Wetland System with Eleocharis SP. using SR-XRF

    Energy Technology Data Exchange (ETDEWEB)

    Avelino Neto, Sebastiao; Moreira, Silvana [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mails: savneto@bol.com.br; silvana@fec.unicamp.br

    2007-07-01

    The pollution of the water resources for metals, results of different economic activities. The objective of the present study was to use the SR-TXRF technique to evaluate the performance of Wetland system cultivated with Eleocharis sp. installed at FEAGRI-UNICAMP, in the metal removal. The metals analyzed were Cr, Mn, Fe, Zn and Pb. Samples of the wastewater in the exit, Eleocharis sp. leaf and medium boulder were collected during 20 weeks consecutively. The system was operated with different outflows and hydraulic detention times (HDT) as: 600 L.day{sup -1} (HDT 2 days), 400 L.day-1 (HDT 3 days), 300 L.day{sup -1} (HDT 4 days) and 200 L.day{sup -1} (HDT 6 days). The main source of metal removal was medium boulder with efficiency varying 30.1% for Cr and 98.9% for Pb, independent of the hydraulic detention time (HDT) used. The efficiency of the wetland in the Cr removal varied between 39.6 and 98.7%, and for Mn was higher than 81.6%. For Fe the performance was higher than 70.6% and for Cu the efficiency varied between 88.4 and 99.7 %, while for Pb the variation was 67.5 to 98.4 %. The wetland system with Eleocharis sp were in agreement with CONAMA legislation concern to Fe, Cu and Zn removal and for HDT of 2, 3, 4 and 6 days (HDT), moreover for Mn was necessary 4 and 6 days (HDT) and for Cr and Pb 6 days (HDT). (author)

  3. Removal of Retained Adherent Placental Remnants Using the Hysteroscopy Endo-Operative System.

    Science.gov (United States)

    Zhu, Ke-An; Huang, Huan; Xue, Min; Subedi, Jigyasa; Jamail, Grace; Zhao, Weidong; Xu, Dabao; Xiao, Songshu

    2016-01-01

    Removal of retained adherent placental remnants (RAPRs) may be challenging using traditional 5Fr or 7Fr hysteroscopic grasping forceps because they are very small. This is particularly true when the retained placental remnant is large. This video demonstrates the advantages of using the Hysteroscopy Endo-Operative System (HEOS), a specially designed operative hysteroscope with a 13Fr working channel, to remove retained placental remnants. Step-by-step explanation of the technique using videos and pictures (educative video) (Canadian Task Force Classification III). Third Xiangya Hospital of Central South University, Hunan, China. A 32-year-old woman was diagnosed with RAPRs 5 weeks after the evacuation of retained placenta after a spontaneous abortion at 16 weeks' gestation. Gynecologic examination revealed an anterior 8-week uterus and no tenderness. Serum β-human chorionic gonadotropin was 150 mIU/L. Sonography revealed an irregular intrauterine mass, 3.5 cm × 3.5 cm × 3 cm in size. Removal of RAPRs using HEOS (Sopro-comeg Company, Bordeaux, France). The operation time was only 12 minutes. The RAPRs were removed completely and quickly in 1 procedure with no complications. The serum β-human chorionic gonadotropin titer normalized 1 week after the procedure. This study was approved by the institutional review board of the Third Xiangya Hospital of Central South University. When indicated, removal of RAPRs using HEOS is safe and simple because of its large and strong cold forceps. Additionally, it avoids electrical and thermal injury to the endometrium, which is particularly important in a population that wants to preserve fertility. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  4. Comparison of filter media materials for heavy metal removal from urban stormwater runoff using biofiltration systems.

    Science.gov (United States)

    Lim, H S; Lim, W; Hu, J Y; Ziegler, A; Ong, S L

    2015-01-01

    The filter media in biofiltration systems play an important role in removing potentially harmful pollutants from urban stormwater runoff. This study compares the heavy metal removal potential (Cu, Zn, Cd, Pb) of five materials (potting soil, compost, coconut coir, sludge and a commercial mix) using laboratory columns. Total/dissolved organic carbon (TOC/DOC) was also analysed because some of the test materials had high carbon content which affects heavy metal uptake/release. Potting soil and the commercial mix offered the best metal uptake when dosed with low (Cu: 44.78 μg/L, Zn: 436.4 μg/L, Cd, 1.82 μg/L, Pb: 51.32 μg/L) and high concentrations of heavy metals (Cu: 241 μg/L, Zn: 1127 μg/L, Cd: 4.57 μg/L, Pb: 90.25 μg/L). Compost and sludge also had high removal efficiencies (>90%). Heavy metal leaching from these materials was negligible. A one-month dry period between dosing experiments did not affect metal removal efficiencies. TOC concentrations from all materials increased after the dry period. Heavy metal removal was not affected by filter media depth (600 mm vs. 300 mm). Heavy metals tended to accumulate at the upper 5 cm of the filter media although potting soil showed bottom-enriched concentrations. We recommend using potting soil as the principal media mixed with compost or sludge since these materials perform well and are readily available. The use of renewable materials commonly found in Singapore supports a sustainable approach to urban water management. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. High-efficiency SO{sub 2} removal in utility FGD systems

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, J.L.; Gray, S.; Dekraker, D. [Radian Corporation, Austin, TX (United States)] [and others

    1995-11-01

    The U.S. Department of Energy (DOE) and the Electric Power Research Institute (EPRI) have contracted with Radian Corporation to conduct full-scale testing, process modeling, and economic evaluations of six existing utility flue gas desulfurization (FGD) systems. The project objective is to evaluate low capital cost upgrades for achieving up to 98% sulfur dioxide (SO{sub 2}) removal efficiency in a variety of FGD system types. The systems include dual-loop, packed absorbers at Tampa Electric Company`s Big Bend Station; cocurrent, packed absorbers at Hoosier Energy`s Merom Station; dual-loop absorbers with perforated-plate trays at Southwestern Electric Power Company`s Pirkey Station; horizontal spray absorbers at PSI Energy`s Gibson Station; venturi scrubbers at Duquesne Light`s Elrama Station; and open stray absorbers at New york State Electric and Gas Corporations`s (NYSEG`s) Kintigh Station. All operate in an inhibited-oxidation mode except the system at Big Bend (forced oxidation), and all use limestone reagent except the Elrama system (Mg-lime). The program was conducted to demonstrate that upgrades such as performance additives and/or mechanical modifications can increase system SO{sub 2} removal at low cost. The cost effectiveness of each upgrade has been evaluated on the basis of test results and/or process model predictions for upgraded performance and utility-specific operating and maintenance costs. Results from this upgraded performance and utility-specific operating and maintenance costs. Results from this program may lead some utilities to use SO{sub 2} removal upgrades as an approach for compliance with phase 2 of Title IV of the Clean Air Act Amendments (CAAA) of 1990. This paper summarizes the results of testing, modeling, and economic evaluations that have been completed since July, 1994.

  6. Bacteriophage Technique for Assessing Viral Removal in Constructed Wetland and Detention Pond Systems

    Directory of Open Access Journals (Sweden)

    Z Yousefi, CM Davies, HJ Bavor

    2004-10-01

    Full Text Available Constructed wetland and detention pond as a treatment system was applied for stormwater management in two adjacent areas in western Sydney. F-specific RNA and somatic coliphages were used as a model for assessing two systems for removal of viral pollution, fate, behavior and survival of viruses in the sediment. Water samples were collected weekly in sterile containers and sediment samples were collected three times using a box dredge sampler via a boat at the inlet, middle and outlet areas of the systems. F-specific RNA coliphages were enumerated using the double layer plaque assay (ISO 1995 with Salmonella typhimurium WG49 as a host. Survival test continued 28 d for each sub-sample. Viral removal in constructed wetland was more effective than the detention pond system. Survival of somatic coliphages in the inlet and middle of the systems was similar. Slope of declining for outlet of two systems was very slow and completely stable in whole of test duration. Constructed wetland may offer an attractive alternative to stormwater management for reducing the load of disease-causing viruses to the receiving waters.

  7. Study on grey theoretical model of passive residual heat removal system

    International Nuclear Information System (INIS)

    Zhou Tao; Yang Ruichang; Su, G.H.; Jia Dounan; Sugiyama, K.

    2004-01-01

    Natural Circulation Passive Residual Heat Removal System is treated as a Grey System by taking into account of its complexity and uncertainty of effect for factors each other. The magnitude and degree of some factors are confirmed by grey incidence analysis method; The one-one relationship of some variables is built by GM (1, 1) model; The relationship between key factor and other effect factors is built (1, 4) model. Grey model shows its more advantage of precision through comparing with multivariate model. (author)

  8. A portable system for acquiring and removing motion artefact from ECG signals

    Science.gov (United States)

    Griffiths, A.; Das, A.; Fernandes, B.; Gaydecki, P.

    2007-07-01

    A novel electrocardiograph (ECG) signal acquisition and display system is under development. It is designed for patients ranging from the elderly to athletes. The signals are obtained from electrodes integrated into a vest, amplified, digitally processed and transmitted via Bluetooth to a PC with a Labview ® interface. Digital signal processing is performed to remove movement artefact and electromyographic (EMG) noise, which severely distorts signal morphology and complicates clinical diagnosis. Independent component analysis (ICA) is also used to improve the signal quality. The complete system will integrate the electronics into a single module which will be embedded in the vest.

  9. A portable system for acquiring and removing motion artefact from ECG signals

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, A; Das, A; Fernandes, B; Gaydecki, P [School of Electrical and Electronic Engineering, University of Manchester, PO Box 88, Manchester M60 1QD (United Kingdom)

    2007-07-15

    A novel electrocardiograph (ECG) signal acquisition and display system is under development. It is designed for patients ranging from the elderly to athletes. The signals are obtained from electrodes integrated into a vest, amplified, digitally processed and transmitted via Bluetooth to a PC with a Labview (registered) interface. Digital signal processing is performed to remove movement artefact and electromyographic (EMG) noise, which severely distorts signal morphology and complicates clinical diagnosis. Independent component analysis (ICA) is also used to improve the signal quality. The complete system will integrate the electronics into a single module which will be embedded in the ves000.

  10. Loss of residual heat removal system: Diablo Canyon, Unit 2, April 10, 1987

    International Nuclear Information System (INIS)

    1987-06-01

    This report presents the findings of an NRC Augmented Inspection Team (AIT) investigation into the circumstances associated with the loss of residual heat removal (RHR) system capability for a period of approximately one and one-half hours at the Diablo Canyon, Unit 2 reactor facility on April 10, 1987. This event occurred while the Diablo Canyon, Unit 2, a pressurized water reactor, was shutdown with the reactor coolant system (RCS) water level drained to approximately mid-level of the hot leg piping. The reactor containment building equipment hatch was removed at the time of the event, and plant personnel were in the process of removing the primary side manways to gain access into the steam generator channel head areas. Thus, two fission product barriers were breached throughout the event. The RCS temperature increased from approximately 87 0 F to bulk boiling conditions without RCS temperature indication available to the plant operators. The RCS was subsequently pressurized to approximately 7 to 10 psig. The NRC AIT members concluded that the Diablo Canyon, Unit 2 plant was, at the time of the event, in a condition not previously analyzed by the NRC staff. The AIT findings from this event appear significant and generic to other pressurized water reactor facilities licensed by the NRC

  11. Baseline repeated measures from controlled human exposure studies: associations between ambient air pollution exposure and the systemic inflammatory biomarkers IL-6 and fibrinogen.

    Science.gov (United States)

    Thompson, Aaron M S; Zanobetti, Antonella; Silverman, Frances; Schwartz, Joel; Coull, Brent; Urch, Bruce; Speck, Mary; Brook, Jeffrey R; Manno, Michael; Gold, Diane R

    2010-01-01

    Systemic inflammation may be one of the mechanisms mediating the association between ambient air pollution and cardiovascular morbidity and mortality. Interleukin-6 (IL-6) and fibrinogen are biomarkers of systemic inflammation that are independent risk factors for cardio-vascular disease. We investigated the association between ambient air pollution and systemic inflammation using baseline measurements of IL-6 and fibrinogen from controlled human exposure studies. In this retrospective analysis we used repeated-measures data in 45 nonsmoking subjects. Hourly and daily moving averages were calculated for ozone, nitrogen dioxide, sulfur dioxide, and particulate matter pollutants on systemic IL-6 and fibrinogen. Effect modification by season was considered. We observed a positive association between IL-6 and O3 [0.31 SD per O3 interquartile range (IQR); 95% confidence interval (CI), 0.080.54] and between IL-6 and SO2 (0.25 SD per SO2 IQR; 95% CI, 0.060.43). We observed the strongest effects using 4-day moving averages. Responses to pollutants varied by season and tended to be higher in the summer, particularly for O3 and PM2.5. Fibrinogen was not associated with pollution. This study demonstrates a significant association between ambient pollutant levels and baseline levels of systemic IL-6. These findings have potential implications for controlled human exposure studies. Future research should consider whether ambient pollution exposure before chamber exposure modifies IL-6 response.

  12. Design of the cryogenic systems for the Near and Far LAr-TPC detectors of the Short-Baseline Neutrino program (SBN) at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Geynisman, M. [Fermilab; Bremer, J. [CERN; Chalifour, M. [CERN; Delaney, M. [Fermilab; Dinnon, M. [Fermilab; Doubnik, R. [Fermilab; Hentschel, S. [Fermilab; Kim, M. J. [Fermilab; Montanari, C. [INFN, Pavia; Monatanari, D. [Fermilab; Nichols, T. [Fermilab; Norris, B. [Fermilab; Sarychev, M. [Fermilab; Schwartz, F. [Fermilab; Tillman, J. [Fermilab; Zuckerbrot, M. [Fermilab

    2017-08-31

    The Short-Baseline Neutrino (SBN) physics program at Fermilab and Neutrino Platform (NP) at CERN are part of the international Neutrino Program leading to the development of Long-Baseline Neutrino Facility/Deep Underground Neutrino Experiment (LBNF/DUNE) science project. The SBN program consisting of three Liquid Argon Time Projection Chamber (LAr-TPC) detectors positioned along the Booster Neutrino Beam (BNB) at Fermilab includes an existing detector known as MicroBooNE (170-ton LAr-TPC) plus two new experiments known as SBN’s Near Detector (SBND, ~260 tons) and SBN’s Far Detector (SBN-FD, ~760 tons). All three detectors have distinctly different design of their cryostats thus defining specific requirements for the cryogenic systems. Fermilab has already built two new facilities to house SBND and SBN-FD detectors. The cryogenic systems for these detectors are in various stages of design and construction with CERN and Fermilab being responsible for delivery of specific sub-systems. This contribution presents specific design requirements and typical implementation solutions for each sub-system of the SBND and SBN-FD cryogenic systems.

  13. Removal Efficiency of Nitrogen, Phosphorus and Heavy Metal by Intermittent Cycle Extended Aeration System from Municipal Wastewater (Yazd-ICEAS

    Directory of Open Access Journals (Sweden)

    Seyed Vahid Ghelmani

    2016-09-01

    Conclusion: The high removal efficiency of BOD5, TKN, and NH4+ showed that this advanced SBR system had an appropriate efficiency for nitrification. Phosphorus removal (TP had a lower efficiency than those of NH4+ and TKN, but it was within the environmental standard limits. On the other hand, in the advanced SBR the removal efficiency of heavy metals for Cd was not within the standard limits.

  14. Assessment of alternate ion exchange resins for improved antimony removal from the primary heat transport system

    Energy Technology Data Exchange (ETDEWEB)

    Burany, R.; Suryanarayan, S.; Husain, A. [Kinectrics, Inc., Toronto, ON (Canada)

    2015-07-01

    Radiation fields around the CANDU heat transport system are a major contributor to worker dose during inspection, maintenance and refurbishment activities. While Co-60 is typically the dominant contributor to radiation fields in CANDU reactors, Sb-124, an activation product of antimony, is also a significant contributor, accounting for 5-20% of the radiation fields. The goal of this research project was to investigate resins for improved removal of antimony under both oxidizing and reducing conditions.Several candidate resins were tested and short-listed through a sequence of iterative testing. The results of the laboratory testing have identified potential candidates for improved antimony removal. Further testing is required to ensure compatibility with existing station resin specifications. (author)

  15. Concepts for passive heat removal and filtration systems under core meltdown conditions

    International Nuclear Information System (INIS)

    Wilhelm, J.G.; Neitzel, H.-J.

    1993-01-01

    The objective of the new containment concept being developed by KfK is the complete passive enclosure of a power reactor after a core meltdown accident by means of a solid containment structure and passive removal of the decay heat. This is to be accomplished by cooling the containment walls with ambient air, with thermoconvection as the driving force. The concept of the containment is described. Data are given of the heat removal and the requirements for filtration of the exhaust air, which is contaminated due to the leak rate assumed for the inner containment. The concept for the filter system is described. Various solutions for reduction of the large volumetric flow to be filtered are discussed. 3 refs., 8 figs

  16. Preliminary analysis of West Valley Waste Removal System equipment development and mock demonstration facilities

    International Nuclear Information System (INIS)

    Janicek, G.P.

    1981-06-01

    This report defines seven areas requiring further investigation to develop and demonstrate a safe and viable West Valley Waste Removal System. These areas of endeavor are discussed in terms of their minimum facility requirements. It is concluded that utilizing separated specific facilities at different points in time is of a greater advantage than an exact duplication of the West Valley tanks. Savannah River Plant's full-scale, full-circle and half-circle tanks, and their twelfth scale model tank would all be useful to varying degrees but would require modifications. Hanford's proposed full-size mock tank would be useful, but is not seriously considered because its construction may not coincide with West Valley needs. Costs of modifying existing facilities and/or constructing new facilities are assessed in terms of their benefit to the equipment development and mock demonstration. Six facilities were identified for further analysis which would benefit development of waste removal equipment

  17. Numerical simulation of flow field in cooling tower of passive residual heat removal system of HTGR

    International Nuclear Information System (INIS)

    Li Xiaowei; Zhang Li; Wu Xinxin; He Shuyan

    2011-01-01

    Environmental wind will influence the working conditions of natural convection cooling tower. The velocity and temperature fields in the natural convection cooling tower of the HTGR residual heat removal system at different environmental wind velocities were numerically simulated. The results show that, if there is no wind baffle, the flow in the cooling tower is blocked when environmental wind velocity is higher than 6 m/s, residual heat can hardly be removed, and when wind velocity is higher than 9 m/s, the air even flow downwards in the tower, so wind baffle is very necessary. With the wind baffle installed, the cooling tower works well at the wind speed even higher than 9 m/s. The optimum baffle size and positions are also analyzed. (authors)

  18. Nitrogen removal kinetics in the treatment of landfill leachate by SBR systems

    International Nuclear Information System (INIS)

    Andreottola, G.; Foladori, P.; Ragazzi, M.

    1998-01-01

    In this study, laboratory-scale experiments were conducted applying the SBR activated sludge process to leachate from an old MSW landfill operating for 7 years. Due to the fact that old leachate is characterized with a high concentration of ammonia (approximately 1500 mgN/1) and low availability of readily biodegradable organic matter (BOD 5 /COD,06), the aim was to examine the nitrogen removal process and to compare the efficiency of one-stage and two stage systems operating at temperature of 20 C and 12 C. The second alternative SBR configuration is based on the coupling of two SBR reactors: the first one specialized in nitrification and the second one in post-denitrification, with external carbon source addition. By the efficient removal of nitrogen, an on-site pretreatment of leachate allows to comply with the limits required for discharging into sewers or into municipal wastewater treatment plant [it

  19. Application of the PSA method to decay heat removal systems in a large scale FBR design

    International Nuclear Information System (INIS)

    Kotake, S.; Satoh, K.; Matsumoto, H.; Sugawara, M.; Sakata, K.; Okabe, A.

    1993-01-01

    The Probabilistic Safety Assessment (PSA) method is applied to a large scale loop-type FBR in its conceptual design stage in order to establish a well-balanced safety. Both the reactor shut down and decay heat removal systems are designed to be highly reliable, e.g. 10 -7 /d. In this paper the results of several reliability analyses concerning the DHRS have been discussed, where the effects of the analytical assumptions, design options, accident managements on the reliability are examined. The reliability is evaluated small enough, since DRACSs consists of four independent loops with sufficient heat removal capacity and both forced and natural circulation capabilities are designed. It is found that the common mode failures for the active components in the DRACS dominate the reliability. The design diversity concerning these components can be effective for the improvements and the accident managements on BOP are also possible by making use of the long grace period in FBR. (author)

  20. Application of the PSA method to decay heat removal systems in a large scale FBR design

    Energy Technology Data Exchange (ETDEWEB)

    Kotake, S; Satoh, K [Japan Atomic Power Company, Otemachi, Chiyoda-ku, Tokyo (Japan); Matsumoto, H; Sugawara, M [Toshiba Corporation (Japan); Sakata, K [Mitsubishi Atomic Power Industries Inc. (Japan); Okabe, A [Hitachi Engineering Co., Ltd. (Japan)

    1993-02-01

    The Probabilistic Safety Assessment (PSA) method is applied to a large scale loop-type FBR in its conceptual design stage in order to establish a well-balanced safety. Both the reactor shut down and decay heat removal systems are designed to be highly reliable, e.g. 10{sup -7}/d. In this paper the results of several reliability analyses concerning the DHRS have been discussed, where the effects of the analytical assumptions, design options, accident managements on the reliability are examined. The reliability is evaluated small enough, since DRACSs consists of four independent loops with sufficient heat removal capacity and both forced and natural circulation capabilities are designed. It is found that the common mode failures for the active components in the DRACS dominate the reliability. The design diversity concerning these components can be effective for the improvements and the accident managements on BOP are also possible by making use of the long grace period in FBR. (author)

  1. A TBB-CUDA Implementation for Background Removal in a Video-Based Fire Detection System

    Directory of Open Access Journals (Sweden)

    Fan Wang

    2014-01-01

    Full Text Available This paper presents a parallel TBB-CUDA implementation for the acceleration of single-Gaussian distribution model, which is effective for background removal in the video-based fire detection system. In this framework, TBB mainly deals with initializing work of the estimated Gaussian model running on CPU, and CUDA performs background removal and adaption of the model running on GPU. This implementation can exploit the combined computation power of TBB-CUDA, which can be applied to the real-time environment. Over 220 video sequences are utilized in the experiments. The experimental results illustrate that TBB+CUDA can achieve a higher speedup than both TBB and CUDA. The proposed framework can effectively overcome the disadvantages of limited memory bandwidth and few execution units of CPU, and it reduces data transfer latency and memory latency between CPU and GPU.

  2. Copper (II) Removal In Anaerobic Continuous Column Reactor System By Using Sulfate Reducing Bacteria

    Science.gov (United States)

    Bilgin, A.; Jaffe, P. R.

    2017-12-01

    Copper is an essential element for the synthesis of the number of electrons carrying proteins and the enzymes. However, it has a high level of toxicity. In this study; it is aimed to treat copper heavy metal in anaerobic environment by using anaerobic continuous column reactor. Sulfate reducing bacteria culture was obtained in anaerobic medium using enrichment culture method. The column reactor experiments were carried out with bacterial culture obtained from soil by culture enrichment method. The system is operated with continuous feeding and as parallel. In the first rector, only sand was used as packing material. The first column reactor was only fed with the bacteria nutrient media. The same solution was passed through the second reactor, and copper solution removal was investigated by continuously feeding 15-600 mg/L of copper solution at the feeding inlet in the second reactor. When the experiment was carried out by adding the 10 mg/L of initial copper concentration, copper removal in the rate of 45-75% was obtained. In order to determine the use of carbon source during copper removal of mixed bacterial cultures in anaerobic conditions, total organic carbon TOC analysis was used to calculate the change in carbon content, and it was calculated to be between 28% and 75%. When the amount of sulphate is examined, it was observed that it changed between 28-46%. During the copper removal, the amounts of sulphate and carbon moles were equalized and more sulfate was added by changing the nutrient media in order to determine the consumption of sulphate or carbon. Accordingly, when the concentration of added sulphate is increased, it is calculated that between 35-57% of sulphate is spent. In this system, copper concentration of up to 15-600 mg / L were studied.

  3. Simulation and optimisation of the data acquisition system for tritium removal pilot plant

    International Nuclear Information System (INIS)

    Retevoi, Carmen Maria; Stefan, Iuliana; Balteanu, Ovidiu; Stefan, Liviu

    2004-01-01

    Optimization and simulation of systems especially in science and engineering can help to reduce risk and cost of design and testing processes. A huge number of codes has been developed to support modeling and simulation efforts. All of these software tools support the use of one or more mathematical model classes. Despite all of these efforts, it is hard to find simulation software, which is capable of combining several model classes in a real industry standard environment. The paper presents a simulation software product for controlling and data acquisition system of cryogenic installation process in the tritium removal pilot plant, using an industry standard programming environment widely applied to data acquisition, process control and data visualization, namely LabView. One of the problems in a tritium separation installation is controlling the temperature. To solve this problem it is necessary to develop a simulation system which includes the mathematical model for cryogenic distillation. Also with this simulation system we can approach the safety system which ensures the monitoring of radiations and toxic gases from installation. All elements used in controlling, modeling and simulation of the process, as well as, in the datalogging and supervisory control module from tritium removal installation are new. (authors)

  4. Technical solutions for tritium removal from Cernavoda NPP heavy water systems

    International Nuclear Information System (INIS)

    Barariu, Gheorghe; Panait, Adrian

    2002-01-01

    In CANDU nuclear plants 2400 KCi/GW(e) - year tritium is generated. At a CANDU - 600 reactor similar to Cernavoda NPP Unit 1, 1500 KCi/year of tritium is generated 95% being in the D 2 O moderator, which can achieve a radioactivity level of 80 - 100 Ci/kg. Tritium in heavy water contributes with 30 - 50% to the doses received by operation personnel and with 20% to the radioactivity released to the environment. The extraction of tritium heavy water at CANDU reactors implies the following possibilities: - the radioactivity level reduction in the operation area; - the maintenance and repair cost reduction due to reduction of personnel protection measures and increased labor productivity; - the increase of NPP utilization factor by shutdown time reduction for maintenance and repair; - tritium concentration reduction from technological systems, ensuring thus the possibility of redesigning the systems in order to lower the cost of investment; - profitable use of extracted tritium. Technical measures provided by AECL project for CANDU 600 at Cernavoda make possible to satisfy the current standards concerning tritium concentration in the operation area atmosphere of 5 x 10 -6 Ci/m 3 . The regulations recommend that the radioactivity level should be maintained as low as possible in conformity with ALARA principles. Also, it is possible that norms will become more restrictive in the future, so the tritium removal technology is a good preventive measure which may become very necessary. The methods, which currently reached the industrial or pilot stages, are based on catalyzed chemical exchange, the heavy water electrolysis, and deuterium distillation. They are known as: VPCE - Vapour Phase Catalytic Exchange; LPCE - Liquid Phase Catalytic Exchange; DE - Direct Electrolysis; CD - Cryogenic Distillation. As transfer processes the catalyzed chemical exchange and heavy water electrolysis are used while concentration of tritium gas is done by cryogenic distillation. At present the

  5. Electrically enhanced MBR system for total nutrient removal in remote northern applications.

    Science.gov (United States)

    Wei, V; Elektorowicz, M; Oleszkiewicz, J A

    2012-01-01

    Thousands of sparsely populated communities scatter in the remote areas of northern Canada. It is economically preferable to adopt the decentralized systems to treat the domestic wastewater because of the vast human inhabitant distribution and cold climatic conditions. Electro-technologies such as electrofiltration, elctrofloatation, electrocoagulation and electrokinetic separation have been applied in water and conventional wastewater treatment for decades due to the minimum requirements of chemicals as well as ease of operation. The membrane bioreactor (MBR) is gaining popularity in recent years as an alternative water/wastewater treatment technology. However, few studies have been conducted to hyphenate these two technologies. The purpose of this work is to design a novel electrically enhanced membrane bioreactor (EMBR) as an alternative decentralized wastewater treatment system with improved nutrient removal and reduced membrane fouling. Two identical submerged membranes (GE ZW-1 hollow fiber module) were used for the experiment, with one as a control. The EMBR and control MBR were operated for 4 months at room temperature (20 ± 2 °C) with synthetic feed and 2 months at 10 °C with real sewage. The following results were observed: (1) the transmembrane pressure (TMP) increased significantly more slowly in the EMBR and the interval between the cleaning cycles of the EMBR increased at least twice; (2) the dissolved chemical oxygen demand (COD) or total organic carbon (TOC) in the EMBR biomass was reduced from 30 to 51%, correspondingly, concentrations of the extracellular polymeric substances (EPS), the major suspicious membrane foulants, decreased by 26-46% in the EMBR; (3) both control and EMBR removed >99% of ammonium-N and >95% of dissolved COD, in addition, ortho-P removal in the EMBR was >90%, compared with 47-61% of ortho-P removal in the MBR; and (4) the advantage of the EMBR over the conventional MBR in terms of membrane fouling retardation and

  6. Passive Decay Heat Removal Strategy of Integrated Passive Safety System (IPSS) for SBO-combined Accidents

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Ho; Chang, Soon Heung; Jeong, Yong Hoon [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-10-15

    The weak points of nuclear safety would be in outmoded nuclear power plants like the Fukushima reactors. One of the systems for the safety enhancement is integrated passive safety system (IPSS) proposed after the Fukushima accidents. It has the five functions for the prevention and mitigation of a severe accident. Passive decay heat removal (PDHR) strategy using IPSS is proposed for coping with SBO-combined accidents in this paper. The two systems for removing decay heat before core-melt were applied in the strategy. The accidents were simulated by MARS code. The reference reactor was OPR1000, specifically Ulchin-3 and 4. The accidents included loss-of-coolant accidents (LOCA) because the coolant losses could be occurred in the SBO condition. The examples were the stuck open of PSV, the abnormal open of SDV and the leakage of RCP seal water. Also, as LOCAs with the failure of active safety injection systems were considered, various LOCAs were simulated in SBO. Based on the thermal hydraulic analysis, the probabilistic safety analysis was carried out for the PDHR strategy to estimate the safety enhancement in terms of the variation of core damage frequency. AIMS-PSA developed by KAERI was used for calculating CDF of the plant. The IPSS was applied in the PDHR strategy which was developed in order to cope with the SBO-combined accidents. The estimation for initiating SGGI or PSIS was based on the pressure in RCS. The simulations for accidents showed that the decay heat could be removed for the safety duration time in SBO. The increase of safety duration time from the strategy provides the increase of time for the restoration of AC power.

  7. Passive afterheat removal in the HTGR with the liner cooling system as a heat sink

    International Nuclear Information System (INIS)

    Rehm, W.; Jahn, W.; Verfondern, K.

    1984-09-01

    The report deals with the transients of temperature and system pressure and the fission product behaviour in the primary circuit of an HTGR during passive afterheat removal, where the liner cooling system of the PCRV serves as a heat sink. The analysis has been made for the PNP-500-reactor representing nuclear plants with medium thermal power. The investigations show that the liner cooling system is able to control a core heatup. High temperature loads are encountered in the upper core region. In the case of a reactor under pressure the fuel elements and the primary circuit remain intact as the first and second barriers for fission products. In the case of a depressurized primary circuit the liner cooling system also keeps the PCRV at normal operating temperatures. The effects of a core heatup on component damage and release of fission products are thus limited. (orig.) [de

  8. Removal of Airborne Contaminants from a Surface Tank by a Push-Pull System

    DEFF Research Database (Denmark)

    Heiselberg, Per; Topp, Claus

    Open surface tanks are used in many industrial processes, and local exhaust systems are often designed to capture and remove toxic fumes diffused from materials in the tanks prior to their escape into the workplace environment. The push-pull system seems to be the most efficient local exhaust...... system, but proper design is required to ensure health and safety of the workers and, furthermore, it is very desirable from an energy conservation point of view to determine an optimum and -an efficient design of push-pull hoods which can exhaust all contaminants with a minimum quantity of volume flow....... The paper describes and discusses different design methods and compares designed values with results from a measurement series of push-pull system efficiency....

  9. [Treatment of removable partial dentures. 2. Causes and consequences of a reduced occlusal system].

    Science.gov (United States)

    Witter, D J; Barèl, J C; de Baat, C; Keltjens, H M A M; Creugers, N H J

    2011-01-01

    The occlusal system is part of the orofacial system and consists of the maxillary and mandibular alveolar ridge and teeth which are occluding or not or the removable denture teeth. The most prevalent causes of loss of teeth are insufficient oral self care or inadequate professional oral healthcare service. A reduced dentition can be described in terms of diastemas in the anterior region and number of occluding pairs of (pre)molars, differentiated as interrupted or shortened dental arches. Characteristic of a healthy functional occlusal system are the absence of pathology and the possibility to practice all oral functions without inconvenience. The consequences of a reduced occlusal system may be overload and/or migration of teeth, mandibular instability, and impaired esthetics and chewing function. Morphological and functional alterations can be considered to be adaptations to changed situations or to be pathological. The distinction between adaptation and pathology cannot be sharply defined. If prosthetic replacement of teeth is needed, the trend is to avoid removable partial dentures.

  10. Field Test Program for Long-Term Operation of a COHPAC System for Removing Mercury from Coal-Fired Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    C. Jean Bustard; Charles Lindsey; Paul Brignac

    2006-05-01

    This document provides a summary of the full-scale demonstration efforts involved in the project ''Field Test Program for Long-Term Operation of a COHPAC{reg_sign} System for Removing Mercury from Coal-Fired Flue Gas''. The project took place at Alabama Power's Plant Gaston Unit 3 and involved the injection of sorbent between an existing particulate collector (hot-side electrostatic precipitators) and a COHPAC{reg_sign} fabric filter (baghouse) downstream. Although the COHPAC{reg_sign} baghouse was designed originally for polishing the flue gas, when activated carbon injection was added, the test was actually evaluating the EPRI TOXECON{reg_sign} configuration. The results from the baseline tests with no carbon injection showed that the cleaning frequency in the COHPAC{reg_sign} unit was much higher than expected, and was above the target maximum cleaning frequency of 1.5 pulses/bag/hour (p/b/h), which was used during the Phase I test in 2001. There were times when the baghouse was cleaning continuously at 4.4 p/b/h. In the 2001 tests, there was virtually no mercury removal at baseline conditions. In this second round of tests, mercury removal varied between 0 and 90%, and was dependent on inlet mass loading. There was a much higher amount of ash exiting the electrostatic precipitators (ESP), creating an inlet loading greater than the design conditions for the COHPAC{reg_sign} baghouse. Tests were performed to try to determine the cause of the high ash loading. The LOI of the ash in the 2001 baseline tests was 11%, while the second baseline tests showed an LOI of 17.4%. The LOI is an indication of the carbon content in the ash, which can affect the native mercury uptake, and can also adversely affect the performance of ESPs, allowing more ash particles to escape the unit. To overcome this, an injection scheme was implemented that balanced the need to decrease carbon injection during times when inlet loading to the baghouse was high and

  11. Horizontal Heat Exchanger Design and Analysis for Passive Heat Removal Systems

    Energy Technology Data Exchange (ETDEWEB)

    Vierow, Karen

    2005-08-29

    This report describes a three-year project to investigate the major factors of horizontal heat exchanger performance in passive containment heat removal from a light water reactor following a design basis accident LOCA (Loss of Coolant Accident). The heat exchanger studied in this work may be used in advanced and innovative reactors, in which passive heat removal systems are adopted to improve safety and reliability The application of horizontal tube-bundle condensers to passive containment heat removal is new. In order to show the feasibility of horizontal heat exchangers for passive containment cooling, the following aspects were investigated: 1. the condensation heat transfer characteristics when the incoming fluid contains noncondensable gases 2. the effectiveness of condensate draining in the horizontal orientation 3. the conditions that may lead to unstable condenser operation or highly degraded performance 4. multi-tube behavior with the associated secondary-side effects This project consisted of two experimental investigations and analytical model development for incorporation into industry safety codes such as TRAC and RELAP. A physical understanding of the flow and heat transfer phenomena was obtained and reflected in the analysis models. Two gradute students (one funded by the program) and seven undergraduate students obtained research experience as a part of this program.

  12. Cadmium analysis using field deployable nano-band electrode system and its removal using electrocoagulation

    Science.gov (United States)

    Guttula, Mallikarjuna Murthy

    Cadmium (Cd) is an extremely toxic metal commonly found in industrial workplaces. Major industrial releases of Cd stem from waste streams, leaching of landfills, and from a variety of operations that involve cadmium or zinc. Particularly, cadmium can be released to drinking water from the corrosion of some galvanized plumbing and water main pipe materials. The United State Environmental Protection Agency (USEPA) has set the Maximum Contaminant Level (MCL) for cadmium at 5 ppb. Long term exposure of cadmium above the MCL results in kidney, liver, bone and blood damage. An accurate and rapid measurement of cadmium in the field remains a technical challenge. In this work, a relatively new method of a Nano-Band Electrode system using anodic stripping voltammetry was optimized by changing deposition potential, electrolyte, and plating time. We efficiently used Electrocoagulation remove cadmium from wastewater and obtained a removal efficiency of +/-99%. Removal mechanism of cadmium in electrocoagulation was also proposed with the help of X-ray Diffraction (XRD), Attenuated Total Reflection - Fourier Transform Infra Red Spectroscopy (ATR-FTIR), and Scanning Electron Microscopy and Energy Dispersive Spectrometer (SEM-EDS).

  13. Arsenic removal using steel manufacturing byproducts as permeable reactive materials in mine tailing containment systems.

    Science.gov (United States)

    Ahn, Joo Sung; Chon, Chul-Min; Moon, Hi-Soo; Kim, Kyoung-Woong

    2003-05-01

    Steel manufacturing byproducts were tested as a means of treating mine tailing leachate with a high As concentration. Byproduct materials can be placed in situ as permeable reactive barriers to control the subsurface release of leachate from tailing containment systems. The tested materials had various compositions of elemental Fe, Fe oxides, Ca-Fe oxides and Ca hydroxides typical of different steel manufacturing processes. Among these materials, evaporation cooler dust (ECD), oxygen gas sludge (OGS), basic oxygen furnace slag (BOFS) and to a lesser degree, electrostatic precipitator dust (EPD) effectively removed both As(V) and As(III) during batch experiments. ECD, OGS and BOFS reduced As concentrations to <0.5mg/l from 25mg/l As(V) or As(III) solution in 72 h, exhibiting higher removal capacities than zero-valent iron. High Ca concentrations and alkaline conditions (pH ca. 12) provided by the dissolution of Ca hydroxides may promote the formation of stable, sparingly soluble Ca-As compounds. When initial pH conditions were adjusted to 4, As reduction was enhanced, probably by adsorption onto iron oxides. The elution rate of retained As from OGS and ECD decreased with treatment time, and increasing the residence time in a permeable barrier strategy would be beneficial for the immobilization of As. When applied to real tailing leachate, ECD was found to be the most efficient barrier material to increase pH and to remove As and dissolved metals.

  14. Design of CAREM-25 Residual Heat Removal System: Nuclear Safety Aspects

    International Nuclear Information System (INIS)

    Zanocco, Pablo; Gimenez, Marcelo; Schlamp, Miguel; Barrera, M.

    2000-01-01

    In this paper Carem-25 residual heat removal system (RHRS) design is analyzed from the nuclear safety point of view.The proposed RHRS is a condenser that transfers the heat to a pool located in the upper level of the containment.The RHRS design basis accident is a reactor loss of heat sink.The following requirements were settled to be verified: a) To remove 2 MW, for a primary circuit pressure of 12.25 MPa and a pool temperature of 100 0 C. b) No condenser tubes flooding, for a primary circuit pressure of 14 MPa and a pool temperature of 100 0 C. c) To reach hot shutdown in 48-hrs, that is to remove of 0.6 MW for a primary circuit pressure of 2.3 MPa and a pool temperature of 120 0 C.Heat transfer regimes inside and outside the condenser and flow patterns were analyzed.Steady state conditions for the above design conditions were modeled.The design requirements were verified taking into account heat transfer coefficients uncertainties and their propagation to the equipment elevation in the containment over the RPV, in order to minimize its elevation and its possible flooding.The resulting condenser tubes were 2 S CH 160 TP 347 SS, with a total area of 4 m 2 and a required minimum height of 6 m from the RPV water level to the condenser outlet headers

  15. Baseline comparison report for Project W-058, Replacement of the cross-site transfer system. Revision 1

    International Nuclear Information System (INIS)

    Mendoza, D.P.

    1995-01-01

    This BCR compares the Project W-058 Functional Design Criteria with the Project W-058 Preliminary Design Requirements Document, and identifies the differences between the two documents in the mission definition, project requirements, system functions, and interfaces. Impacts these differences have on current project design are also discussed

  16. Application of bacteriophages to selectively remove Pseudomonas aeruginosa in water and wastewater filtration systems.

    Science.gov (United States)

    Zhang, Yanyan; Hunt, Heather K; Hu, Zhiqiang

    2013-09-01

    Water and wastewater filtration systems often house pathogenic bacteria, which must be removed to ensure clean, safe water. Here, we determine the persistence of the model bacterium Pseudomonas aeruginosa in two types of filtration systems, and use P. aeruginosa bacteriophages to determine their ability to selectively remove P. aeruginosa. These systems used beds of either anthracite or granular activated carbon (GAC), which were operated at an empty bed contact time (EBCT) of 45 min. The clean bed filtration systems were loaded with an instantaneous dose of P. aeruginosa at a total cell number of 2.3 (± 0.1 [standard deviation]) × 10(7) cells. An immediate dose of P. aeruginosa phages (1 mL of phage stock at the concentration of 2.7 × 10(7) PFU (Plaque Forming Units)/mL) resulted in a reduction of 50% (± 9%) and >99.9% in the effluent P. aeruginosa concentrations in the clean anthracite and GAC filters, respectively. To further evaluate the effects of P. aeruginosa phages, synthetic stormwater was run through anthracite and GAC biofilters where mixed-culture biofilms were present. Eighty five days after an instantaneous dose of P. aeruginosa (2.3 × 10(7) cells per filter) on day 1, 7.5 (± 2.8) × 10(7) and 1.1 (± 0.5) × 10(7) P. aeruginosa cells/g filter media were detected in the top layer (close to the influent port) of the anthracite and GAC biofilters, respectively, demonstrating the growth and persistence of pathogenic bacteria in the biofilters. A subsequent 1-h dose of phages, at the concentration of 5.1 × 10(6) PFU/mL and flow rate of 1.6 mL/min, removed the P. aeruginosa inside the GAC biofilters and the anthracite biofilters by 70% (± 5%) and 56% (± 1%), respectively, with no P. aeruginosa detected in the effluent, while not affecting ammonia oxidation or the ammonia-oxidizing bacterial community inside the biofilters. These results suggest that phage treatment can selectively remove pathogenic bacteria with minimal impact on beneficial

  17. Primary Angiitis of the Central Nervous System: Magnetic Resonance Imaging Spectrum of Parenchymal, Meningeal, and Vascular Lesions at Baseline.

    Science.gov (United States)

    Boulouis, Grégoire; de Boysson, Hubert; Zuber, Mathieu; Guillevin, Loïc; Meary, Eric; Costalat, Vincent; Pagnoux, Christian; Naggara, Olivier

    2017-05-01

    Primary angiitis of the central nervous system remains challenging. To report an overview and pictorial review of brain magnetic resonance imaging findings in adult primary angiitis of the central nervous system and to determine the distribution of parenchymal, meningeal, and vascular lesions in a large multicentric cohort. Adult patients from the French COVAC cohort (Cohort of Patients With Primary Vasculitis of the Central Nervous System), with biopsy or angiographically proven primary angiitis of the central nervous system and brain magnetic resonance imaging available at the time of diagnosis were included. A systematic imaging review was performed blinded to clinical data. Sixty patients met inclusion criteria. Mean age was 45 years (±12.9). Patients initially presented focal deficit(s) (83%), headaches (53%), cognitive disorder (40%), and seizures (38.3%). The most common magnetic resonance imaging finding observed in 42% of patients was multiterritorial, bilateral, distal acute stroke lesions after small to medium artery distribution, with a predominant carotid circulation distribution. Hemorrhagic infarctions and parenchymal hemorrhages were also frequently found in the cohort (55%). Acute convexity subarachnoid hemorrhage was found in 26% of patients and 42% demonstrated pre-eminent leptomeningeal enhancement, which is found to be significantly more prevalent in biopsy-proven patients (60% versus 28%; P =0.04). Seven patients had tumor-like presentations. Seventy-seven percent of magnetic resonance angiographic studies were abnormal, revealing proximal/distal stenoses in 57% and 61% of patients, respectively. Adult primary angiitis of the central nervous system is a heterogenous disease, with multiterritorial, distal, and bilateral acute stroke being the most common pattern of parenchymal lesions found on magnetic resonance imaging. Our findings suggest a higher than previously thought prevalence of hemorrhagic transformation and other hemorrhagic

  18. Potential for water salvage by removal of non-native woody vegetation from dryland river systems

    Science.gov (United States)

    Doody, T.M.; Nagler, P.L.; Glenn, E.P.; Moore, G.W.; Morino, K.; Hultine, K.R.; Benyon, R.G.

    2011-01-01

    Globally, expansion of non-native woody vegetation across floodplains has raised concern of increased evapotranspiration (ET) water loss with consequent reduced river flows and groundwater supplies. Water salvage programs, established to meet water supply demands by removing introduced species, show little documented evidence of program effectiveness. We use two case studies in the USA and Australia to illustrate factors that contribute to water salvage feasibility for a given ecological setting. In the USA, saltcedar (Tamarix spp.) has become widespread on western rivers, with water salvage programs attempted over a 50-year period. Some studies document riparian transpiration or ET reduction after saltcedar removal, but detectable increases in river base flow are not conclusively shown. Furthermore, measurements of riparian vegetation ET in natural settings show saltcedar ET overlaps the range measured for native riparian species, thereby constraining the possibility of water salvage by replacing saltcedar with native vegetation. In Australia, introduced willows (Salix spp.) have become widespread in riparian systems in the Murray-Darling Basin. Although large-scale removal projects have been undertaken, no attempts have been made to quantify increases in base flows. Recent studies of ET indicate that willows growing in permanently inundated stream beds have high transpiration rates, indicating water savings could be achieved from removal. In contrast, native Eucalyptus trees and willows growing on stream banks show similar ET rates with no net water salvage from replacing willows with native trees. We conclude that water salvage feasibility is highly dependent on the ecohydrological setting in which the non-native trees occur. We provide an overview of conditions favorable to water salvage. Copyright ?? 2011 John Wiley & Sons, Ltd.

  19. Design of the cryogenic systems for the Near and Far LAr-TPC detectors of the Short-Baseline Neutrino program (SBN) at Fermilab

    CERN Document Server

    Geynisman, M; Chalifour, M; Delaney, M; Dinnon, M; Doubnik, R; Hentschel, S; Kim, M J; Montanari, C; Montanari, D; Nichols, T; Norris, B; Sarychev, M; Schwartz, F; Tillman, J; Zuckerbrot, M

    2017-01-01

    The Short-Baseline Neutrino (SBN) physics program at Fermilab and Neutrino Platform (NP) at CERN are part of the international Neutrino Program leading to the development of Long-Baseline Neutrino Facility/Deep Underground Neutrino Experiment (LBNF/DUNE) science project. The SBN program consisting of three Liquid Argon Time Projection Chamber (LAr-TPC) detectors positioned along the Booster Neutrino Beam (BNB) at Fermilab includes an existing detector known as MicroBooNE (170-ton LAr-TPC) plus two new experiments known as SBN’s Near Detector (SBND, ~260 tons) and SBN’s Far Detector (SBN-FD, ~760 tons). All three detectors have distinctly different design of their cryostats thus defining specific requirements for the cryogenic systems. Fermilab has already built two new facilities to house SBND and SBN-FD detectors. The cryogenic systems for these detectors are in various stages of design and construction with CERN and Fermilab being responsible for delivery of specific sub-systems. This contribution prese...

  20. The application of polyelectrolytes to improve liquid radwaste treatment system radionuclide removal efficiency

    International Nuclear Information System (INIS)

    Homyk, W.A.; Spall, M.J.; Vance, J.N.

    1990-01-01

    At nuclear plants, miscellaneous waste water treated in the liquid radwaste processing system contains a significant fraction of suspended particulate materials ranging in size from a few microns down to the submicron region. The fewer particles that typically exist as colloids are generally negatively charged by virtue of inorganic and organic anions absorbed onto the particle surfaces. Because many of the radionuclides exist as colloids and resist agglomeration and settling they are not easily removed by mechanical filtration or ion exchange processes. The colloidal materials will easily pass through most filters with conventional pore size ratings and through most ion exchange media. This leads to poor decontamination Factors (dFs) and higher radionuclide releases to the environment. A laboratory-scale testing program was conducted at Indian Point Unit No. 2 to determine the effectiveness of the use of organic polyelectrolytes to destabilize colloidal suspensions in liquid radwaste. Destabilizing colloidal suspensions will improve the removal efficiencies of the suspended material by typical filtration and ion exchange processes. The increased removal efficiencies will provide increased dFs in the liquid radwaste treatment system. The testing focused on identifying the specific organic polyelectrolytes and the associated dosages which would be effective in destabilizing the colloidal suspensions on actual waste water samples. The testing also examined the filtration characteristics of the water source to determine filter parameters such as: body feed material, body feed dosages, specific flow rates, etc., which would provide the basis for the design of filtration systems for these applications. The testing effort and the major conclusions from this investigation are given. 4 refs., 8 figs., 2 tabs

  1. Demographic patterns and trends in Central Ghana: baseline indicators from the Kintampo Health and Demographic Surveillance System

    Directory of Open Access Journals (Sweden)

    Seth Owusu-Agyei

    2012-12-01

    Full Text Available Background: The dearth of health and demographic data in sub-Saharan Africa from vital registration systems and its impact on effective planning for health and socio-economic development is widely documented. Health and Demographic Surveillance Systems have the capacity to address the dearth of quality data for policy making in resource-poor settings. Objective: This article demonstrates the utility of the Kintampo Health and Demographic Surveillance System (KHDSS by showing the patterns and trends of population change from 2005 to 2009 in the Kintampo North Municipality and Kintampo South districts of Ghana through data obtained from the KHDSS biannual update rounds. Design: Basic demographic rates for fertility, mortality, and migration were computed by year. School enrolment was computed as a percentage in school by age and sex for 6–18 year-olds. Socio-economic status was derived by use of Principal Components Analysis on household assets. Results: Over the period, an earlier fertility decline was reversed in 2009; mortality declined slightly for all age-groups, and a significant share of working-age population was lost through out-migration. Large minorities of children of school-going age are not in school. Socio-economic factors are shown to be important determinants of fertility and mortality. Conclusion : Strengthening the capacity of HDSSs could offer added value to evidence-driven policymaking at local level.

  2. Experience with new retrieval forceps for foreign body removal in the vascular and urinary systems

    International Nuclear Information System (INIS)

    Selby, J.B.; Bittner, G.M.; Tegtmeyer, C.J.

    1989-01-01

    A new type of forceps for foreign-body retrieval has recently become available. It consists of single- or multiple-toothed forceps mounted on a flexible, stainless steel shaft. The authors have used this device successfully three times in the vascular system and seven times in the urinary tract without complications. Foreign bodies removed include a catheter fragment, angiographic guidewire, detachable balloon, stone basket, and various ureteral stents. All the procedures were performed quickly and without difficulty. These forceps have become the authors' first choice in many retrieval situations

  3. Gadolinium removal from the moderator system of TAPP - 3 using the three layer bed

    International Nuclear Information System (INIS)

    Tripathi, V.S.; Balaji, V.; Venkateswaran, G.; Dash, S.C.

    2008-01-01

    Nitric acid leaching from the weak base anion (WBA) exchanger had been evaluated and based on this a 5% mixture of nitric acid loaded weak base anion exchanger with fresh weak base anion exchanger (NLWBA) at the bottom of the ion exchange column has been devised to maintain an outlet pH in the range of 5.0 to 5.5 during Gd removal from the moderator system of TAPP - 3 and 4. A three layered bed had been constituted wherein strong acid cation (SAC) exchanger is placed as the top layer while a mixed bed of SAC and WBA or pure WBA is used as the middle layer and the 5% NLWBA was used as the bottom most layer. This bed configuration would result in an iso-pH regime in the moderator system during the Gd removal along with quantitative removal of Gd. Two three-layer bed columns were prepared at TAPS - 3 and 4 in July 07. The resin was loaded in batches and after preparing the column, the column was deuterated with heavy water (> 99.75 % w/w) at a steady flow rate of 280 ml/min. After achieving high-grade isotopic purity viz. > 99.75 % w/w., these columns were preserved for their use after SDS - 2 actuation in the plant. Biennial Shut Down (BSD) of Unit - 3 was taken on 04-05-08 by SDS-2 actuation resulting in 16.37 ppm Gd in the moderator system. Gd removal to the extent about 8 mg/kg as designed could be done on one three layer bed. The use of this bed has resulted in an iso-pH regime at the column inlet and outlet. Conductivity values observed in the system were within the specifications. The three layer bed of a configuration slightly modified from the one tested in this work is expected to improve the column efficiency to 100% from the presently observed 87% and 97% respectively for the IX-2 and IX-3. (author)

  4. A value/impact assessment for alternative decay heat removal systems

    International Nuclear Information System (INIS)

    Cave, L.; Kastenberg, W.E.; Lin, K.Y.

    1984-01-01

    A Value/Impact assessment for several alternative decay heat removal systems has been carried out using several measures. The assessment is based on an extension of the methodology presented in the Value/Impact Handbook and includes the effects of uncertainty. The assessment was carried out as a function of site population density, existing plant features, and new plant features. Value/Impact measures based on population dose are shown to be sensitive to site, while measures which monetize and aggregate risk are less so. The latter are dominated by on-site costs such as replacement power costs. (orig.)

  5. Arsenic removal by discontinuous ZVI two steps system for drinking water production at household scale.

    Science.gov (United States)

    Casentini, Barbara; Falcione, Fabiano Teo; Amalfitano, Stefano; Fazi, Stefano; Rossetti, Simona

    2016-12-01

    Different countries in Europe still suffer of elevated arsenic (As) concentration in groundwaters used for human consumption. In the case of households not connected to the distribution system, decentralized water supply systems, such as Point of Use (POU) and Point of Entry (POE), offer a direct benefit for the consumers. Field scale ex-situ treatment systems based on metallic iron (ZVI) are already available for the production of reduced volumes of drinking water in remote areas (village scale). To address drinking water needs at larger scale, we designed a pilot unit able to produce an elevated daily volume of water for human consumption. We tested the long-term As removal efficiency of a two steps ZVI treatment unit for the production of 400 L/day clean water based on the combination of ZVI corrosion process with sedimentation and retention of freshly formed Fe precipitates. The system treated 100 μg/L As(V)-contaminated oxic groundwater in a discontinuous operation mode at a flow rate of 1 L/min for 31 days. Final removal was 77-96% and the most performing step was aeration/sedimentation (A/S) tank with a 60-94% efficiency. Arsenic in the outflow slightly exceeded the drinking water limit of 10 μg/L only after 6000 L treated and Fe concentration was always below 0.2 mg/L. Under proposed operating conditions ZVI passivation readily occurred and, as a consequence, Fe production sharply decreased. Arsenic mobility attached to particulate was 13-60% after ZVI column and 37-100% after A/S tank. Uniform amorphous cluster of Fe nanoparticles (100 nm) formed during aeration drove As removal process with an adsorption capacity corresponding to 20.5 mg As /g Fe . Research studies often focus only on chemico-physical aspects disregarding the importance of biological processes that may co-occur and interfere with ZVI corrosion, As removal and safe water production. We explored the microbial transport dynamics by flow cytometry, proved as a suitable tool to

  6. A study on the silica removal in primary system using the membrane process

    International Nuclear Information System (INIS)

    Kim, Bong Jin; Lee, Sang Jin; Yang, Ho Yeon; Kim, Kyung Duk; Jung, Hee Chul; Jo, Hang Rae

    2005-01-01

    Silica in primary system combines with an alkali grammatical particle metal and forms the zeolite layer which is hindering the heat transfer on the surface of the cladding. Zeolite layer becomes the cause of the damage in this way. The problems of the NPP's primary system have been issued steadily by EPRI. Through a series of experiments of the laboratory scale, we confirmed the applicability of NF membrane for silica removal, as silica rejection rate of NF membrane is about 60 ∼ 70% and boron rejection rate is about 10 ∼ 20%. We accomplished a site experiment about four NF membranes manufactured by FilmTec and Osmonics Inc. In experiment using 400L of SFP water, when operation pressure is 10kg f /cm 2 , we confirmed that the silica rejection rate of NF90-2540 manufactured by FilmTec Inc. is about 98%, boron rejection rate is about 43%. The silica rejection rate of NF270-2540 is about 38%, boron rejection rate is about 3.5%. Afterward, through additional experiments, such as long term characteristic experiments, we are going to design a optimum NF membrane system for silica removal

  7. Technical specification improvements to containment heat removal and emergency core cooling systems: Final report

    International Nuclear Information System (INIS)

    Sullivan, W.P.; Ha, C.; Pentzien, D.C.; Visweswaran, S.

    1988-07-01

    This report presents the results of an analysis for technical specification improvements to the emergency core cooling systems (ECCS) and containment heat removal systems (EPRI Research Project 2142-3). The objective of this project is to further develop a reliability- and risk-based methodology to provide improvements by considering groups of surveillance test intervals and allowed out-of-service times jointly. This was done for the technical specifications for the ECCS, containment heat removal equipment, and supporting systems of a boiling water reactor plant. The project (1) developed a methodology for optimizing groups of surveillance test intervals and allowed out-of-service times jointly, (2) applied the methodology in a case study of a specific operating plant, Hatch-2, and (3) evaluated benefits of the application. The results of the case study demonstrate that beneficial technical specification improvements can be realized with application of the methodology. By tightening a small group of sensitive surveillance test intervals (STIs) and allowed out-of-service times (AOTs), a larger group of less sensitive STIs and AOTs can be extended resulting in an overall plant operating cost improvement without reducing the plant safety. The reliability- and risk-based methodology and results from this project can be effectively applied for technical specification improvements at other operating plants

  8. Study of passive residual heat removal system of a modular small PWR reactor

    International Nuclear Information System (INIS)

    Araujo, Nathália N.; Su, Jian

    2017-01-01

    This paper presents a study on the passive residual heat removal system (PRHRS) of a small modular nuclear reactor (SMR) of 75MW. More advanced nuclear reactors, such as generation III + and IV, have passive safety systems that automatically go into action in order to prevent accidents. The purpose of the PRHRS is to transfer the decay heat from the reactor's nuclear fuel, keeping the core cooled after the plant has shut down. It starts operating in the event of fall of power supply to the nuclear station, or in the event of an unavailability of the steam generator water supply system. Removal of decay heat from the core of the reactor is accomplished by the flow of the primary refrigerant by natural circulation through heat exchangers located in a pool filled with water located above the core. The natural circulation is caused by the density gradient between the reactor core and the pool. A thermal and comparative analysis of the PRHRS was performed consisting of the resolution of the mass conservation equations, amount of movement and energy and using incompressible fluid approximations with the Boussinesq approximation. Calculations were performed with the aid of Mathematica software. A design of the heat exchanger and the cooling water tank was done so that the core of the reactor remained cooled for 72 hours using only the PRHRS

  9. A study on the silica removal in primary system using the membrane process

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Jin; Lee, Sang Jin; Yang, Ho Yeon; Kim, Kyung Duk [Korea Hydro and Nuclear Power Co., LTD., Taejeon (Korea, Republic of); Jung, Hee Chul; Jo, Hang Rae [Korea Hydro and Nuclear Power Co., LTD., Uljin (Korea, Republic of)

    2005-06-15

    Silica in primary system combines with an alkali grammatical particle metal and forms the zeolite layer which is hindering the heat transfer on the surface of the cladding. Zeolite layer becomes the cause of the damage in this way. The problems of the NPP's primary system have been issued steadily by EPRI. Through a series of experiments of the laboratory scale, we confirmed the applicability of NF membrane for silica removal, as silica rejection rate of NF membrane is about 60 {approx} 70% and boron rejection rate is about 10 {approx} 20%. We accomplished a site experiment about four NF membranes manufactured by FilmTec and Osmonics Inc. In experiment using 400L of SFP water, when operation pressure is 10kg{sub f}/cm{sup 2}, we confirmed that the silica rejection rate of NF90-2540 manufactured by FilmTec Inc. is about 98%, boron rejection rate is about 43%. The silica rejection rate of NF270-2540 is about 38%, boron rejection rate is about 3.5%. Afterward, through additional experiments, such as long term characteristic experiments, we are going to design a optimum NF membrane system for silica removal.

  10. GFDL's ESM2 global coupled climate-carbon Earth System Models. Part I: physical formulation and baseline simulation characteristics

    Science.gov (United States)

    Dunne, John P.; John, Jasmin G.; Adcroft, Alistair J.; Griffies, Stephen M.; Hallberg, Robert W.; Shevalikova, Elena; Stouffer, Ronald J.; Cooke, William; Dunne, Krista A.; Harrison, Matthew J.; Krasting, John P.; Malyshev, Sergey L.; Milly, P.C.D.; Phillipps, Peter J.; Sentman, Lori A.; Samuels, Bonita L.; Spelman, Michael J.; Winton, Michael; Wittenberg, Andrew T.; Zadeh, Niki

    2012-01-01

    We describe the physical climate formulation and simulation characteristics of two new global coupled carbon-climate Earth System Models, ESM2M and ESM2G. These models demonstrate similar climate fidelity as the Geophysical Fluid Dynamics Laboratory's previous CM2.1 climate model while incorporating explicit and consistent carbon dynamics. The two models differ exclusively in the physical ocean component; ESM2M uses Modular Ocean Model version 4.1 with vertical pressure layers while ESM2G uses Generalized Ocean Layer Dynamics with a bulk mixed layer and interior isopycnal layers. Differences in the ocean mean state include the thermocline depth being relatively deep in ESM2M and relatively shallow in ESM2G compared to observations. The crucial role of ocean dynamics on climate variability is highlighted in the El Niño-Southern Oscillation being overly strong in ESM2M and overly weak ESM2G relative to observations. Thus, while ESM2G might better represent climate changes relating to: total heat content variability given its lack of long term drift, gyre circulation and ventilation in the North Pacific, tropical Atlantic and Indian Oceans, and depth structure in the overturning and abyssal flows, ESM2M might better represent climate changes relating to: surface circulation given its superior surface temperature, salinity and height patterns, tropical Pacific circulation and variability, and Southern Ocean dynamics. Our overall assessment is that neither model is fundamentally superior to the other, and that both models achieve sufficient fidelity to allow meaningful climate and earth system modeling applications. This affords us the ability to assess the role of ocean configuration on earth system interactions in the context of two state-of-the-art coupled carbon-climate models.

  11. The role and control of sludge age in biological nutrient removal activated sludge systems.

    Science.gov (United States)

    Ekama, G A

    2010-01-01

    The sludge age is the most fundamental and important parameter in the design, operation and control of biological nutrient removal (BNR) activated sludge (AS) systems. Generally, the better the effluent and waste sludge quality required from the system, the longer the sludge age, the larger the biological reactor and the more wastewater characteristics need to be known. Controlling the reactor concentration does not control sludge age, only the mass of sludge in the system. When nitrification is a requirement, sludge age control becomes a requirement and the secondary settling tanks can no longer serve the dual purpose of clarifier and waste activated sludge thickeners. The easiest and most practical way to control sludge age is with hydraulic control by wasting a defined proportion of the reactor volume daily. In AS plants with reactor concentration control, nitrification fails first. With hydraulic control of sludge age, nitrification will not fail, rather the plant fails by shedding solids over the secondary settling tank effluent weirs.

  12. CAREM 25: Design of resin bed for purification and boron removal systems

    International Nuclear Information System (INIS)

    Chocron, Mauricio; Iglesias, Alberto M.; Jimenez Rebagliati, Raul; Raffo Calderon, Maria C.; La Gamma, Ana M.

    2000-01-01

    The purification of the water the primary coolant of a water cooled nuclear reactor as well as the water of many auxiliary systems is controlled by the use of ion exchange resins. In the present paper, the resin beds for three different systems are specified: the purification and control volume system, the suppression pool water and the spent fuel pool water for the reactor CAREM-25. In all cases the dimensioning calculations have been done taking in consideration the amount of contaminants and corrosion products generated under normal operation or post-accident. Also, the results have been contrasted with the experience of the nuclear power plants in operation in Argentina, international design criteria and international standards. For the primary coolant, the boron-removal beds have been sized and an estimation of the maximum dose received by the resins have been calculated. It have been found that the result is well below the damaging threshold reported in the literature. (author)

  13. Sixty Percent Conceptual Design Report: Enterprise Accountability System for Classified Removable Electronic Media

    Energy Technology Data Exchange (ETDEWEB)

    B. Gardiner; L.Graton; J.Longo; T.Marks, Jr.; B.Martinez; R. Strittmatter; C.Woods; J. Joshua

    2003-05-03

    Classified removable electronic media (CREM) are tracked in several different ways at the Laboratory. To ensure greater security for CREM, we are creating a single, Laboratory-wide system to track CREM. We are researching technology that can be used to electronically tag and detect CREM, designing a database to track the movement of CREM, and planning to test the system at several locations around the Laboratory. We focus on affixing ''smart tags'' to items we want to track and installing gates at pedestrian portals to detect the entry or exit of tagged items. By means of an enterprise database, the system will track the entry and exit of tagged items into and from CREM storage vaults, vault-type rooms, access corridors, or boundaries of secure areas, as well as the identity of the person carrying an item. We are considering several options for tracking items that can give greater security, but at greater expense.

  14. Assessing the removal of organic micropollutants by a novel baffled osmotic membrane bioreactor-microfiltration hybrid system

    KAUST Repository

    Pathak, Nirenkumar

    2018-04-14

    A novel approach was employed to study removal of organic micropollutants (OMPs) in a baffled osmotic membrane bioreactor-microfiltration (OMBR-MF) hybrid system under oxic–anoxic conditions. The performance of OMBR-MF system was examined employing three different draw solutes (DS), and three model OMPs. The highest forward osmosis (FO) membrane rejection was attained with atenolol (100 %) due to its higher molar mass and positive charge. With inorganic DS caffeine (94-100 %) revealed highest removal followed by atenolol (89-96 %) and atrazine (16-40 %) respectively. All three OMPs exhibited higher removal with organic DS as compared to inorganic DS. Significant anoxic removal was observed for atrazine under very different redox conditions with extended anoxic cycle time. This can be linked with possible development of different microbial consortia responsible for diverse enzymes secretion. Overall, the OMBR-MF process showed effective removal of total organic carbon (98%) and nutrients (phosphate 97% and total nitrogen 85%), respectively.

  15. Assessing the removal of organic micropollutants by a novel baffled osmotic membrane bioreactor-microfiltration hybrid system

    KAUST Repository

    Pathak, Nirenkumar; Li, Sheng; Kim, Youngjin; Chekli, Laura; Phuntsho, Sherub; Jang, Am; Ghaffour, NorEddine; Leiknes, TorOve; Shon, Ho Kyong

    2018-01-01

    A novel approach was employed to study removal of organic micropollutants (OMPs) in a baffled osmotic membrane bioreactor-microfiltration (OMBR-MF) hybrid system under oxic–anoxic conditions. The performance of OMBR-MF system was examined employing three different draw solutes (DS), and three model OMPs. The highest forward osmosis (FO) membrane rejection was attained with atenolol (100 %) due to its higher molar mass and positive charge. With inorganic DS caffeine (94-100 %) revealed highest removal followed by atenolol (89-96 %) and atrazine (16-40 %) respectively. All three OMPs exhibited higher removal with organic DS as compared to inorganic DS. Significant anoxic removal was observed for atrazine under very different redox conditions with extended anoxic cycle time. This can be linked with possible development of different microbial consortia responsible for diverse enzymes secretion. Overall, the OMBR-MF process showed effective removal of total organic carbon (98%) and nutrients (phosphate 97% and total nitrogen 85%), respectively.

  16. Programmable removal of bacterial strains by use of genome-targeting CRISPR-Cas systems.

    Science.gov (United States)

    Gomaa, Ahmed A; Klumpe, Heidi E; Luo, Michelle L; Selle, Kurt; Barrangou, Rodolphe; Beisel, Chase L

    2014-01-28

    CRISPR (clustered regularly interspaced short palindromic repeats)-Cas (CRISPR-associated) systems in bacteria and archaea employ CRISPR RNAs to specifically recognize the complementary DNA of foreign invaders, leading to sequence-specific cleavage or degradation of the target DNA. Recent work has shown that the accidental or intentional targeting of the bacterial genome is cytotoxic and can lead to cell death. Here, we have demonstrated that genome targeting with CRISPR-Cas systems can be employed for the sequence-specific and titratable removal of individual bacterial strains and species. Using the type I-E CRISPR-Cas system in Escherichia coli as a model, we found that this effect could be elicited using native or imported systems and was similarly potent regardless of the genomic location, strand, or transcriptional activity of the target sequence. Furthermore, the specificity of targeting with CRISPR RNAs could readily distinguish between even highly similar strains in pure or mixed cultures. Finally, varying the collection of delivered CRISPR RNAs could quantitatively control the relative number of individual strains within a mixed culture. Critically, the observed selectivity and programmability of bacterial removal would be virtually impossible with traditional antibiotics, bacteriophages, selectable markers, or tailored growth conditions. Once delivery challenges are addressed, we envision that this approach could offer a novel means to quantitatively control the composition of environmental and industrial microbial consortia and may open new avenues for the development of "smart" antibiotics that circumvent multidrug resistance and differentiate between pathogenic and beneficial microorganisms. Controlling the composition of microbial populations is a critical aspect in medicine, biotechnology, and environmental cycles. While different antimicrobial strategies, such as antibiotics, antimicrobial peptides, and lytic bacteriophages, offer partial solutions

  17. Hydrologic conditions, recharge, and baseline water quality of the surficial aquifer system at Jekyll Island, Georgia, 2012-13

    Science.gov (United States)

    Gordon, Debbie W.; Torak, Lynn J.

    2016-03-08

    An increase of groundwater withdrawals from the surficial aquifer system on Jekyll Island, Georgia, prompted an investigation of hydrologic conditions and water quality by the U.S. Geological Survey during October 2012 through December 2013. The study demonstrated the importance of rainfall as the island’s main source of recharge to maintain freshwater resources by replenishing the water table from the effects of hydrologic stresses, primarily evapotranspiration and pumping. Groundwater-flow directions, recharge, and water quality of the water-table zone on the island were investigated by installing 26 shallow wells and three pond staff gages to monitor groundwater levels and water quality in the water-table zone. Climatic data from Brunswick, Georgia, were used to calculate potential maximum recharge to the water-table zone on Jekyll Island. A weather station located on the island provided only precipitation data. Additional meteorological data from the island would enhance potential evapotranspiration estimates for recharge calculations.

  18. The Development of a Parameterized Scatter Removal Algorithm for Nuclear Materials Identification System Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Grogan, Brandon Robert [Univ. of Tennessee, Knoxville, TN (United States)

    2010-03-01

    This dissertation presents a novel method for removing scattering effects from Nuclear Materials Identification System (NMIS) imaging. The NMIS uses fast neutron radiography to generate images of the internal structure of objects non-intrusively. If the correct attenuation through the object is measured, the positions and macroscopic cross-sections of features inside the object can be determined. The cross sections can then be used to identify the materials and a 3D map of the interior of the object can be reconstructed. Unfortunately, the measured attenuation values are always too low because scattered neutrons contribute to the unattenuated neutron signal. Previous efforts to remove the scatter from NMIS imaging have focused on minimizing the fraction of scattered neutrons which are misidentified as directly transmitted by electronically collimating and time tagging the source neutrons. The parameterized scatter removal algorithm (PSRA) approaches the problem from an entirely new direction by using Monte Carlo simulations to estimate the point scatter functions (PScFs) produced by neutrons scattering in the object. PScFs have been used to remove scattering successfully in other applications, but only with simple 2D detector models. This work represents the first time PScFs have ever been applied to an imaging detector geometry as complicated as the NMIS. By fitting the PScFs using a Gaussian function, they can be parameterized and the proper scatter for a given problem can be removed without the need for rerunning the simulations each time. In order to model the PScFs, an entirely new method for simulating NMIS measurements was developed for this work. The development of the new models and the codes required to simulate them are presented in detail. The PSRA was used on several simulated and experimental measurements and chi-squared goodness of fit tests were used to compare the corrected values to the ideal values that would be expected with no scattering. Using

  19. THE DEVELOPMENT OF A PARAMETERIZED SCATTER REMOVAL ALGORITHM FOR NUCLEAR MATERIALS IDENTIFICATION SYSTEM IMAGING

    Energy Technology Data Exchange (ETDEWEB)

    Grogan, Brandon R [ORNL

    2010-05-01

    This report presents a novel method for removing scattering effects from Nuclear Materials Identification System (NMIS) imaging. The NMIS uses fast neutron radiography to generate images of the internal structure of objects nonintrusively. If the correct attenuation through the object is measured, the positions and macroscopic cross sections of features inside the object can be determined. The cross sections can then be used to identify the materials, and a 3D map of the interior of the object can be reconstructed. Unfortunately, the measured attenuation values are always too low because scattered neutrons contribute to the unattenuated neutron signal. Previous efforts to remove the scatter from NMIS imaging have focused on minimizing the fraction of scattered neutrons that are misidentified as directly transmitted by electronically collimating and time tagging the source neutrons. The parameterized scatter removal algorithm (PSRA) approaches the problem from an entirely new direction by using Monte Carlo simulations to estimate the point scatter functions (PScFs) produced by neutrons scattering in the object. PScFs have been used to remove scattering successfully in other applications, but only with simple 2D detector models. This work represents the first time PScFs have ever been applied to an imaging detector geometry as complicated as the NMIS. By fitting the PScFs using a Gaussian function, they can be parameterized, and the proper scatter for a given problem can be removed without the need for rerunning the simulations each time. In order to model the PScFs, an entirely new method for simulating NMIS measurements was developed for this work. The development of the new models and the codes required to simulate them are presented in detail. The PSRA was used on several simulated and experimental measurements, and chi-squared goodness of fit tests were used to compare the corrected values to the ideal values that would be expected with no scattering. Using the

  20. A Unified Algorithm for Channel Imbalance and Antenna Phase Center Position Calibration of a Single-Pass Multi-Baseline TomoSAR System

    Directory of Open Access Journals (Sweden)

    Yuncheng Bu

    2018-03-01

    Full Text Available The multi-baseline synthetic aperture radar (SAR tomography (TomoSAR system is employed in such applications as disaster remote sensing, urban 3-D reconstruction, and forest carbon storage estimation. This is because of its 3-D imaging capability in a single-pass platform. However, a high 3-D resolution of TomoSAR is based on the premise that the channel imbalance and antenna phase center (APC position are precisely known. If this is not the case, the 3-D resolution performance will be seriously degraded. In this paper, a unified algorithm for channel imbalance and APC position calibration of a single-pass multi-baseline TomoSAR system is proposed. Based on the maximum likelihood method, as well as the least squares and the damped Newton method, we can calibrate the channel imbalance and APC position. The algorithm is suitable for near-field conditions, and no phase unwrapping operation is required. The effectiveness of the proposed algorithm has been verified by simulation and experimental results.

  1. Low concentration volatile organic pollutants removal in combined adsorber-desorber-catalytic reactor system

    Directory of Open Access Journals (Sweden)

    Arsenijević Zorana

    2008-01-01

    Full Text Available The removal of volatile organic compounds (VOCs from numerous emission sources is of crucial importance due to more rigorous demands on air quality. Different technologies can be used to treat the VOCs from effluent gases: absorption, physical adsorption, open flame combustion, thermal and catalytic incineration. Their appropriateness for the specific process depends on several factors such as efficiency, energy consumption, secondary pollution, capital investments etc. The distinctive features of the catalytic combustion are high efficiency and selectivity toward be­nign products, low energy consumption and absence of secondary polluti­on. The supported noble catalysts are widely used for catalytic incineration due to their low ignition temperatures and high thermal and chemical stability. In our combined system adsorption and desorption are applied in the spouted bed with draft tube (SBDT unit. The annular zone, loaded with sorbent, was divided in adsorption and desorption section. Draft tube enabled sorbent recirculation between sections. Combustion of desorbed gases to CO2 and water vapor are realized in additive catalytic reactor. This integrated device provided low concentrations VOCs removal with reduced energy consumption. Experiments were conducted on a pilot unit of 220 m3/h nominal capacity. The sorbent was activated carbon, type K81/B - Trayal Corporation, Krusevac. A sphere shaped commercial Pt/Al2O3 catalyst with "egg-shell" macro-distribution was used for the investigation of xylene deep oxidation. Within this paper the investigations of removal of xylene vapors, a typical pollutant in production of liquid pesticides, in combined adsorber/desorber/catalytic reactor system is presented.

  2. ETV REPORT: REMOVAL OF CHEMICAL CONTAMINANTS IN DRINKING WATER — PALL/KINETICO PUREFECTA DRINKING WATER TREATMENT SYSTEM

    Science.gov (United States)

    The Pall/Kinetico Purefecta™ POU drinking water treatment system was tested for removal of aldicarb, benzene, cadmium, carbofuran, cesium, chloroform, dichlorvos, dicrotophos, fenamiphos, mercury, mevinphos, oxamyl, strontium, and strychnine. The Purefecta™ employs several compon...

  3. The Use of Reactive Materials in Septic Systems for Pathogens and Nitrate Removal

    Science.gov (United States)

    Suhogusoff, A. V.; Hirata, R.; Aravena, R.; Stimson, J.; Robertson, W.

    2009-05-01

    The developing countries have an urgent need for cheap and efficient techniques for the improvement of sanitary conditions in areas without public water supply and sewerage system, especially in suburban regions or irregular occupation areas, where there is a great lack of social assistance. In this type of situations, the inhabitants use dug wells for water use and cesspits for disposal of sewage, which usually contaminates the groundwater with nitrate and microorganisms. As part of a study aiming to develop new sewage treatment systems in an irregular occupation area located at the District of Barragem, south region of the municipality of São Paulo (Brazil), a conventional cesspit (named as "Control") and an alternative septic system were constructed and monitored for a year. The design of the alternative septic system included a 1m thickness reactive barrier constituted by BOF (Budget Oxygen Furnace - a byproduct of the steel-making industry) for pathogens removal, then 1m sand package where the wastewater is oxidized and at the bottom the wastewater is in contact with a 0,5m thickness reactive barrier constituted by sawdust (carbon source), where redox conditions are very reducing and denitrification and even methanogenesis can take place. The chemical and biological data collected in the alternative septic system showed complete removal of the pathogens in the BOF barrier, then nitrification occurred between the BOF and the bottom of sand package. However denitrification in the sawdust barrier was incomplete because of the high pH caused by the BOF materials, which can reduced the number of denitrifiers bacteria present in the sawdust barrier. Isotope analyses that are been carried out in the residual nitrate will provided more information about the extent of the denitrification reaction in the alternative septic system. In case of the control cesspit, it was observed the occurrence of high concentration of ammonium, dissolved organic carbon, CO2, CH4 and low

  4. Biological removal of the xenobiotic trichloroethylene (TCE) through cometabolism in nitrifying systems.

    Science.gov (United States)

    Kocamemi, B Alpaslan; Ceçen, F

    2010-01-01

    In the present study, cometabolic TCE degradation was evaluated using NH(4)-N as the growth-substrate. At initial TCE concentrations up to 845 microg/L, TCE degradation followed first-order kinetics. The increase in ammonium utilization rate favored the degradation of TCE. This ensured that biological transformation of TCE in nitrifying systems is accomplished through a cometabolic pathway by the catalysis of non-specific ammonia oxygenase enzyme of nitrifiers. The transformation yield (T(y)) of TCE, the amount of TCE degraded per unit mass of NH(4)-N, strongly depended on the initial NH(4)-N and TCE concentrations. In order to allow a rough estimation of TCE removal and nitrification at different influent TCE and NH(4)-N concentrations, a linear relationship was developed between 1/T(y) and the initial NH(4)-N/TCE ratio. The estimated T(y) values lead to the conclusion that nitrifying systems are promising candidates for biological removal of TCE through cometabolism.

  5. Removal of Copper by Eichhornia crassipes and the Characterization of Associated Bacteria of the Rhizosphere System

    Directory of Open Access Journals (Sweden)

    Raisa Kabeer

    2014-06-01

    Full Text Available Excess doses of trace element contamination make conventional water treatment methods less effective and more expensive, where in alternative biotechnological applications open up new opportunities with their reduced cost and lesser impacts to the environment. In the present investigation, effectiveness of aquatic macrophyte Eichhornia crassipes was tested for the removal of copper in laboratory conditions. Water samples were collected from macrophytes natural habitat and water tubs used for growing E. crassipes and analysed along with plant tissues for Cu content. The work also characterized the associated microbiota of the rhizosphere system of the E. crassipes as well as the wetland system of its occurrence. Copper concentration of the wetland water samples ranged from 0.009 to 0.03ppm. Six bacterial genera (Acinetobacter, Alcaligenes, Bacillus, Kurthia, Listeria and Chromobacterium were represented in rhizosphere of E.crassipes and 4 bacterial genera (Acinetobacter, Bacillus, Listeria and Chromobacterium were recorded in wetland water samples. Copper resistance studies of the bacterial isolates showed that out of 26 isolates from rhizosphere and 19 strains from water samples,12 of them showed low resistance (80% of copper during 15 days experiment. Copper accumulation was found to be high in the root followed by leaf and petiole. Results of the present study concluded that E. crassipes is an efficient plant for the removal of copper.

  6. Design of DC Conduction Pump for PGSFR Active Decay Heat Removal System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dehee; Hong, Jonggan; Lee, Taeho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    A DC conduction pump has been designed for the ADHRS of PGSFR. A VBA code developed by ANL was utilized to design and optimize the pump. The pump geometry dependent parameters were optimized to minimize the total current while meeting the design requirements. A double-C type dipole was employed to produce the calculated magnetic strength. Numerical simulations for the magnetic field strength and its distribution around the dipole and for the turbulent flow under magnetic force will be carried out. A Direct Current (DC) conduction Electromagnetic Pump (EMP) has been designed for Active Decay Heat Removal System (ADHRS) of PGSFR. The PGSFR has active as well as passive systems for the DHRS. The passive DHRS (PDHRS) works by natural circulation head and the ADHRS is driven by an EMP for the DHRS sodium loop and a blower for the finned-tube sodium-to-air heat exchanger (FHX). An Annular Linear Induction Pump (ALIP) can be also considered for the ADHRS, but DC conduction pump has been chosen. Selection basis of DHRS EMP is addressed and EMP design for single ADHRS loop with 1MWt heat removal capacity is introduced.

  7. Long Baseline Observatory (LBO)

    Data.gov (United States)

    Federal Laboratory Consortium — The Long Baseline Observatory (LBO) comprises ten radio telescopes spanning 5,351 miles. It's the world's largest, sharpest, dedicated telescope array. With an eye...

  8. Including Life Cycle Assessment for decision-making in controlling wastewater nutrient removal systems

    DEFF Research Database (Denmark)

    Corominas, Lluís; Larsen, Henrik Fred; Flores-Alsina, Xavier

    2013-01-01

    This paper focuses on the use of Life Cycle Assessment (LCA) to evaluate the performance of seventeen control strategies in wastewater treatment plants (WWTPs). It tackles the importance of using site-specific factors for nutrient enrichment when decision-makers have to select best operating....../or energy savings present an environmental benefit for N&P and P-deficient systems. This is not the case when addressing N-deficient systems for which the use of chemicals (even for improving N removal efficiencies) is not always beneficial for the environment. A sensitivity analysis on using weighting...... of the impact categories is conducted to assess how value choices (policy decisions) may affect the management of WWTPs. For the scenarios with only N-limitation, the LCA-based ranking of the control strategies is sensitive to the choice of weighting factors, whereas this is not the case for N&P or P...

  9. CO2 and humidity removal system for extended Shuttle missions - Equilibrium testing and performance analysis

    Science.gov (United States)

    Davis, S. H.; Kissinger, L. D.

    1976-01-01

    In Shuttle orbiter cabins, lithium hydroxide (LiOH) canisters are currently planned to be used for CO2 adsorption and condensing heat exchangers for humidity control. In this paper a more effective CO2 and humidity removal method is proposed by replacing the LiOH component with HS-C adsorbent (a polyethylenimine coated acrylic ester), thus eliminating the low temperature constraints on the active thermal control system. Since the adsorption of CO2 and H2O are reversible, a double bed configuration operating cyclicly is planned to provide continuous atmospheric control. Apparatus and the experimental procedure to test the adsorption equilibrium are described and some of the indicative results, tabulated by computers, are presented with the help of exponential expressions and differential equations. By using a computer model of the Shuttle HS-C system, performance predictions are made.

  10. In situ product removal in fermentation systems: improved process performance and rational extractant selection.

    Science.gov (United States)

    Dafoe, Julian T; Daugulis, Andrew J

    2014-03-01

    The separation of inhibitory compounds as they are produced in biotransformation and fermentation systems is termed in situ product removal (ISPR). This review examines recent ISPR strategies employing several classes of extractants including liquids, solids, gases, and combined extraction systems. Improvement through the simple application of an auxiliary phase are tabulated and summarized to indicate the breadth of recent ISPR activities. Studies within the past 5 years that have highlighted and have discussed "second phase" properties, and that have an effect on fermentation performance, are particular focus of this review. ISPR, as a demonstrably effective processing strategy, continues to be widely adopted as more applications are explored; however, focus on the properties of extractants and their rational selection based on first principle considerations will likely be key to successfully applying ISPR to more challenging target molecules.

  11. Removal of nutrients and veterinary antibiotics from swine wastewater by a constructed macrophyte floating bed system.

    Science.gov (United States)

    Xian, Qiming; Hu, Lixia; Chen, Hancheng; Chang, Zhizhou; Zou, Huixian

    2010-12-01

    The potential of three varieties of Italian ryegrass (Lolium multiflorum Lam.), Dryan, Tachimasari and Waseyutaka, to improve the water quality of swine wastewater was evaluated using a constructed macrophyte floating bed system. With respect to reductions in levels of nutrients, chemical oxygen demand (COD), and sulfonamide antimicrobials (SAs, including sulfadiazine, sulfamethazine, and sulfamethoxazole), Dryan performed better than Tachimasari and Waseyutaka. For Dryan, total N was reduced by 84.0%, total P by 90.4%, COD by 83.4% and sulfonamide antimicrobials by 91.8-99.5%. Similar results were observed for Tachimasari and Waseyutaka. The results indicated that the treatment of swine wastewater using the constructed macrophyte floating bed system was effective in the removal of nutrients and veterinary antibiotics. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. Evaluation of the antimicrobial removal device when used with the BACTEC blood culture system

    International Nuclear Information System (INIS)

    Strand, C.L.

    1982-01-01

    A study to determine the value of the Antimicrobial Removal Device (ARD) used in conjunction with radiometric detection of bacteremia using three media was conducted. During a 12-month period, 622 duplicate ARD/BACTEC blood-culture sets were collected. There were 88 positive cultures that yielded 68 pathogenic isolates and 28 probable contaminant isolates. When all patients were considered, 31 pathogenic isolates were detected by both systems, 25 pathogenic isolates were detected faster or only by the BACTEC system, and 12 pathogenic isolates were detected faster or only when the ARD was employed. This difference is statistically significant (P less than 0.05). Thus, the standard BACTEC blood-culture system using three different media was superior to the same BACTEC system using ARD-processed blood specimens. When only patients receiving antimicrobial therapy were considered, there were more pathogenic isolates detected from unprocessed blood than from blood processed in the ARD; however, this difference was not statistically significant. In conclusion, there appears to be no advantage to using the ARD system in conjunction with the three-bottle BACTEC blood-culture system

  13. The steady-state modeling and optimization of a refrigeration system for high heat flux removal

    International Nuclear Information System (INIS)

    Zhou Rongliang; Zhang Tiejun; Catano, Juan; Wen, John T.; Michna, Gregory J.; Peles, Yoav; Jensen, Michael K.

    2010-01-01

    Steady-state modeling and optimization of a refrigeration system for high heat flux removal, such as electronics cooling, is studied. The refrigeration cycle proposed consists of multiple evaporators, liquid accumulator, compressor, condenser and expansion valves. To obtain more efficient heat transfer and higher critical heat flux (CHF), the evaporators operate with two-phase flow only. This unique operating condition necessitates the inclusion of a liquid accumulator with integrated heater for the safe operation of the compressor. Due to the projected incorporation of microchannels into the system to enhance the heat transfer in heat sinks, the momentum balance equation, rarely seen in previous vapor compression cycle heat exchangers modeling efforts, is utilized in addition to the mass and energy balance equations to capture the expected significant microchannel pressure drop witnessed in previous experimental investigations. Using the steady-state model developed, a parametric study is performed to study the effect of various external inputs on the system performance. The Pareto optimization is applied to find the optimal system operating conditions for given heat loads such that the system coefficient of performance (COP) is optimized while satisfying the CHF and other system operation constraints. Initial validation efforts show the good agreement between the experimental data and model predictions.

  14. Enhanced removal of petroleum hydrocarbons using a bioelectrochemical remediation system with pre-cultured anodes

    International Nuclear Information System (INIS)

    Venkidusamy, Krishnaveni; Megharaj, Mallavarapu; Marzorati, Massimo; Lockington, Robin; Naidu, Ravi

    2016-01-01

    Bioelectrochemical remediation (BER) systems such as microbial fuel cells (MFCs) have recently emerged as a green technology for the effective remediation of petroleum hydrocarbon contaminants (PH) coupled with simultaneous energy recovery. Recent research has shown that biofilms previously enriched for substrate degrading bacteria resulted in excellent performance in terms of substrate removal and electricity generation but the effects on hydrocarbon contaminant degradation were not examined. Here we investigate the differences between enriched biofilm anodes and freshly inoculated new anodes in diesel fed single chamber mediatorless microbial fuel cells (DMFC) using various techniques for the enhancement of PH contaminant remediation with concomitant electricity generation. An anodophilic microbial consortium previously selected for over a year through continuous culturing with a diesel concentration of about 800 mg l"−"1 and which now showed complete removal of this concentration of diesel within 30 days was compared to that of a freshly inoculated new anode MFC (showing 83.4% removal of diesel) with a simultaneous power generation of 90.81 mW/m"2 and 15.04 mW/m"2 respectively. The behaviour of pre-cultured anodes at a higher concentration of PH (8000 mg l"−"1) was also investigated. Scanning electron microscopy observation revealed a thick biofilm covering the pre-cultured anodic electrode but not the anode from the freshly inoculated MFC. High resolution imaging showed the presence of thin 60 nm diametre pilus-like projections emanating from the cells. Anodic microbial community profiling confirmed that the selection for diesel degrading exoelectrogenic bacteria had occurred. Identification of a biodegradative gene (alkB) provided strong evidence of the catabolic pathway used for diesel degradation in the DMFCs.

  15. Enhanced removal of petroleum hydrocarbons using a bioelectrochemical remediation system with pre-cultured anodes

    Energy Technology Data Exchange (ETDEWEB)

    Venkidusamy, Krishnaveni [Centre for Environmental Risk Assessment and Remediation (CERAR), University of South (Australia); CRC for Contamination Assessment and Remediation of the Environment (CRCCARE), Mawson Lakes, SA5095 (Australia); Megharaj, Mallavarapu, E-mail: megh.mallavarapu@newcastle.edu.au [Centre for Environmental Risk Assessment and Remediation (CERAR), University of South (Australia); CRC for Contamination Assessment and Remediation of the Environment (CRCCARE), Mawson Lakes, SA5095 (Australia); Global Centre for Environmental Remediation, Faculty of Science and Information Technology, The University of Newcastle, Callaghan, NSW 2308 (Australia); Marzorati, Massimo [Laboratory for Microbial Ecology and Technology (LabMET), Gent University, 9000 Gent (Belgium); Lockington, Robin [Centre for Environmental Risk Assessment and Remediation (CERAR), University of South (Australia); CRC for Contamination Assessment and Remediation of the Environment (CRCCARE), Mawson Lakes, SA5095 (Australia); Naidu, Ravi [Centre for Environmental Risk Assessment and Remediation (CERAR), University of South (Australia); CRC for Contamination Assessment and Remediation of the Environment (CRCCARE), Mawson Lakes, SA5095 (Australia); Global Centre for Environmental Remediation, Faculty of Science and Information Technology, The University of Newcastle, Callaghan, NSW 2308 (Australia)

    2016-01-01

    Bioelectrochemical remediation (BER) systems such as microbial fuel cells (MFCs) have recently emerged as a green technology for the effective remediation of petroleum hydrocarbon contaminants (PH) coupled with simultaneous energy recovery. Recent research has shown that biofilms previously enriched for substrate degrading bacteria resulted in excellent performance in terms of substrate removal and electricity generation but the effects on hydrocarbon contaminant degradation were not examined. Here we investigate the differences between enriched biofilm anodes and freshly inoculated new anodes in diesel fed single chamber mediatorless microbial fuel cells (DMFC) using various techniques for the enhancement of PH contaminant remediation with concomitant electricity generation. An anodophilic microbial consortium previously selected for over a year through continuous culturing with a diesel concentration of about 800 mg l{sup −1} and which now showed complete removal of this concentration of diesel within 30 days was compared to that of a freshly inoculated new anode MFC (showing 83.4% removal of diesel) with a simultaneous power generation of 90.81 mW/m{sup 2} and 15.04 mW/m{sup 2} respectively. The behaviour of pre-cultured anodes at a higher concentration of PH (8000 mg l{sup −1}) was also investigated. Scanning electron microscopy observation revealed a thick biofilm covering the pre-cultured anodic electrode but not the anode from the freshly inoculated MFC. High resolution imaging showed the presence of thin 60 nm diametre pilus-like projections emanating from the cells. Anodic microbial community profiling confirmed that the selection for diesel degrading exoelectrogenic bacteria had occurred. Identification of a biodegradative gene (alkB) provided strong evidence of the catabolic pathway used for diesel degradation in the DMFCs.

  16. Applications of porous electrodes to metal-ion removal and the design of battery systems

    International Nuclear Information System (INIS)

    Trost, G.G.

    1983-09-01

    This dissertation treats the use of porous electrodes as electrochemical reactors for the removal of dilute metal ions. A methodology for the scale-up of porous electrodes used in battery applications is given. Removal of 4 μg Pb/cc in 1 M sulfuric acid was investigated in atmospheric and high-pressure, flow-through porous reactors. The atmospheric reactor used a reticulated vitreous carbon porous bed coated in situ with a mercury film. Best results show 98% removal of lead from the feed stream. Results are summarized in a dimensionless plot of Sherwood number vs Peclet number. High-pressure, porous-electrode experiments were performed to investigate the effect of pressure on the current efficiency. Pressures were varied up to 120 bar on electrode beds of copper or lead-coated spheres. The copper spheres showed high hydrogen evolution rates which inhibited lead deposition, even at high cathodic overpotentials. Use of lead spheres inhibited hydrogen evolution but often resulted in the formation of lead sulfate layers; these layers were difficult to reduce back to lead. Experimental data of one-dimensional porous battery electrodes are combined with a model for the current collector and cell connectors to predict ultimate specific energy and maximum specific power for complete battery systems. Discharge behavior of the plate as a whole is first presented as a function of depth of discharge. These results are combined with the voltage and weight penalties of the interconnecting bus and post, positive and negative active material, cell container, etc. to give specific results for the lithium-aluminum/iron sulfide high-temperature battery. Subject to variation is the number of positive electrodes, grid conductivity, minimum current-collector weight, and total delivered capacity. The battery can be optimized for maximum energy or power, or a compromise design may be selected

  17. Applications of porous electrodes to metal-ion removal and the design of battery systems

    Energy Technology Data Exchange (ETDEWEB)

    Trost, G.G.

    1983-09-01

    This dissertation treats the use of porous electrodes as electrochemical reactors for the removal of dilute metal ions. A methodology for the scale-up of porous electrodes used in battery applications is given. Removal of 4 ..mu..g Pb/cc in 1 M sulfuric acid was investigated in atmospheric and high-pressure, flow-through porous reactors. The atmospheric reactor used a reticulated vitreous carbon porous bed coated in situ with a mercury film. Best results show 98% removal of lead from the feed stream. Results are summarized in a dimensionless plot of Sherwood number vs Peclet number. High-pressure, porous-electrode experiments were performed to investigate the effect of pressure on the current efficiency. Pressures were varied up to 120 bar on electrode beds of copper or lead-coated spheres. The copper spheres showed high hydrogen evolution rates which inhibited lead deposition, even at high cathodic overpotentials. Use of lead spheres inhibited hydrogen evolution but often resulted in the formation of lead sulfate layers; these layers were difficult to reduce back to lead. Experimental data of one-dimensional porous battery electrodes are combined with a model for the current collector and cell connectors to predict ultimate specific energy and maximum specific power for complete battery systems. Discharge behavior of the plate as a whole is first presented as a function of depth of discharge. These results are combined with the voltage and weight penalties of the interconnecting bus and post, positive and negative active material, cell container, etc. to give specific results for the lithium-aluminum/iron sulfide high-temperature battery. Subject to variation is the number of positive electrodes, grid conductivity, minimum current-collector weight, and total delivered capacity. The battery can be optimized for maximum energy or power, or a compromise design may be selected.

  18. Effects of iron and calcium carbonate on contaminant removal efficiencies and microbial communities in integrated wastewater treatment systems.

    Science.gov (United States)

    Zhao, Zhimiao; Song, Xinshan; Zhang, Yinjiang; Zhao, Yufeng; Wang, Bodi; Wang, Yuhui

    2017-12-01

    In the paper, we explored the influences of different dosages of iron and calcium carbonate on contaminant removal efficiencies and microbial communities in algal ponds combined with constructed wetlands. After 1-year operation of treatment systems, based on the high-throughput pyrosequencing analysis of microbial communities, the optimal operating conditions were obtained as follows: the ACW10 system with Fe 3+ (5.6 mg L -1 ), iron powder (2.8 mg L -1 ), and CaCO 3 powder (0.2 mg L -1 ) in influent as the adjusting agents, initial phosphorus source (PO 4 3- ) in influent, the ratio of nitrogen to phosphorus (N/P) of 30 in influent, and hydraulic retention time (HRT) of 1 day. Total nitrogen (TN) removal efficiency and total phosphorus (TP) removal efficiency were improved significantly. The hydrolysis of CaCO 3 promoted the physicochemical precipitation in contaminant removal. Meanwhile, Fe 3+ and iron powder produced Fe 2+ , which improved contaminant removal. Iron ion improved the diversity, distribution, and metabolic functions of microbial communities in integrated treatment systems. In the treatment ACW10, the dominant phylum in the microbial community was PLANCTOMYCETES, which positively promoted nitrogen removal. After 5 consecutive treatments in ACW10, contaminant removal efficiencies for TN and TP respectively reached 80.6% and 57.3% and total iron concentration in effluent was 0.042 mg L -1 . Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Characterization and removal of specific organic constituents in an UASB-trickling-filter system treating domestic wastewater.

    Science.gov (United States)

    Pontes, Patrícia Procópio; Chernicharo, Carlos Augusto de Lemos

    2011-01-01

    This paper presents the characterization of specific organic constituents (carbohydrates, proteins and lipids) in raw sewage and in the anaerobic and aerobic effluents of a demo-scale (500 inhabitants) UASB- trickling-filter system. The evaluation of such parameters was carried out for two operating conditions, either without sludge recirculation (experiment I) from the trickling filter to the UASB reactor or with sludge recirculation (experiment II), for sludge thickening and stabilization, in the anaerobic reactor. The results showed that the contribution of acetic acid, carbohydrates, proteins and lipids amounted for approximately 70% of the total COD fed to the UASB during experiment I, whereas during experiment II these constituents amounted for only around 40% of the total COD. Although very high BOD and COD overall removal efficiencies were observed for the treatment system (around 90% and 80%, respectively), it was possible to infer that these efficiencies were mainly related to the removal of carbohydrates and lipids (around 80% removal), and of other non-identified constituents. The removal of proteins was much lower (around 50% removal), and the relative contribution of proteins to the total COD increased along the treatment course, being responsible for most of the residual COD of the treatment units. In the present system configuration, the UASB reactor played a major role in the removal of carbohydrates, whereas the trickling filter was very effective in the removal of lipids. The return of aerobic sludge for thickening and stabilization in the UASB reactor did not affect its performance.

  20. Planning of experimental removal of cadmium in finite bath system using the chocolate clay B as adsorbent

    International Nuclear Information System (INIS)

    Mota, J.D.; Rodrigues, M.G.F.; Lima, W.S.; Souza, R.S.

    2012-01-01

    The smectite clays are characterized by having a high cation exchange capacity and ability to remove metal ions. They have great industrial importance, for its abundance and low cost. The first part of this work was to characterize the clay called Chocolate B through the techniques of X-Ray Diffraction, X-Ray Spectroscopy and Energy Dispersive Physical Adsorption of Nitrogen. The second part of the work aims to evaluate the significance of the variables: pH and initial concentration on removal of cadmium in a batch system. In the experimental design used was a 2 2 factorial analysis with the addition at the central point, and evaluated the percentage of removal (Rem%) and removal capacity (EQF). XRD results corroborating the chemical analysis (EDX), characterized as a B Chocolate smectite clays. Statistical analysis showed a strong influence of variable pH on the removal of cadmium. (author)

  1. Erosion of Embolization Coils into the Renal Collecting System: Removal with Prone Transradial Renal Arteriography and Nephroscopy.

    Science.gov (United States)

    Srinivasa, Ravi N; Chick, Jeffrey Forris Beecham; Hage, Anthony; Ramamurthi, Aishu; Wolf, J Stuart; Gemmete, Joseph J; Dauw, Casey A

    2017-10-01

    Removal of embolization coils eroded into the renal collecting system poses a risk of hemorrhage, which may need to be addressed with arteriography and embolization at the time of treatment. The purpose of this report is to describe a novel approach, by which prone percutaneous nephroscopic coil retrieval is coupled with simultaneous prone transradial renal arterial access to mitigate this potential complication. A retrospective chart review of the electronic medical record systems was performed from January 2008 to May 2017 to identify patients who had undergone percutaneous removal of embolization coils eroded into the renal collecting system. Patients who had migration of embolization coils into the renal collecting system who were symptomatic with pain, hydronephrosis, or infection were considered for inclusion. Patients who had coil migration, but were asymptomatic were not offered removal. Patient demographics and case characteristics were examined as were operative outcomes. A total of three patients fulfilled the study criteria. Migrated embolization coils were able to be effectively removed in all patients. Of the patients, two underwent simultaneous prone transradial renal arteriography with placement of an occlusion balloon catheter into the segmental artery of interest. In one patient, significant arterial bleeding was encountered after coil removal, which was effectively addressed with simultaneous arteriography and glue embolization. Erosion of embolization coils into the renal collecting system, while rare, may be a significant long-term complication of coil embolization. Combining nephroscopy with prone transradial arteriography in preparation for procedure-associated hemorrhage may make removal of migrated coils safer.

  2. Integrated planning: A baseline development perspective

    International Nuclear Information System (INIS)

    Clauss, L.; Chang, D.

    1994-01-01

    The FEMP Baseline establishes the basis for integrating environmental activity technical requirements with their cost and schedule elements. The result is a path forward to successfully achieving the FERMCO mission. Specific to cost management, the FEMP Baseline has been incorporate into the FERMCO Project Control System (PCS) to provide a time-phased budget plan against which contractor performance is measured with an earned value management system. The result is the Performance Measurement Baseline (PMB), an important tool for keeping cost under control

  3. Enhancing organic matter removal in desalination pretreatment systems by application of dissolved air flotation

    DEFF Research Database (Denmark)

    Shutova, Yulia; Karna, Barun Lal; Hambly, Adam C.

    2016-01-01

    on the sample, respectively. The optimal normalised coagulant dose (Fe3+ to DOC ratio) was observed to be 0.5-4 at pH5.5 increasing to 4-12 at pH7.5. At pH5.5, the optimum coagulant dose increased with increasing humic character of the feed water. Overall, the OM removal efficiency by DAF observed in this study......Membrane fouling in reverse osmosis (RO) systems caused by organic matter (OM) remains a significant operational issue during desalination. Dissolved air flotation (DAF) has recently received attention as a pre-treatment option for seawater OM removal; however, only a limited number of studies have...... been undertaken. This may be because it is difficult to characterise OM in seawater due to the high salt content and low carbon concentration. In this study, DAF pre-treatment experiments were conducted using a model seawater solution, and real seawater and brackish water samples. DAF performance...

  4. Meeting of Specialists on the Reliability of Decay Heat Removal Systems for Fast Reactors. Summary Report

    International Nuclear Information System (INIS)

    1975-10-01

    The Specialists Meeting on Reliability of Decay Heat Removal Systems proposed for Fast Reactors was sponsored by the UKAEA Safety & Reliability Directorate and held at Harwell between 28th April and 1st May, 1975. The meeting was attended by delegates from six countries - (USA, Federal Republic of Germany, France, Japan, USSR and the UK). A list of participants is included in an Appendix to this report. The subject matter of the meeting was concerned with the degree to which the ability to maintain decay heat removal from a fast reactor after shutdown in normal and abnormal circumstances could be guaranteed by design provisions and substantiated by reliability analysis techniques, operational testing etc. Consideration of conditions prevailing after a hypothetical core melt down incident were not included in the subject matter. The deliberations of the meeting were focussed at each working session on a defined theme and its dependant topics as shown in the detailed Agenda included in this report. Although provision had been made in the Agenda for a limited amount of discussion of the decay heat rejection problems of Gas Cooled Fast Reactors, delegates had no contributions to offer on this subject. During each session a Recording Secretary prepared a summary of the main points made by national delegates and of the resulting recommendations and conclusions. These draft summaries were made available to delegates during subsequent sessions of the meeting and approved by them for inclusion in the Summary, General Conclusions and Recommendations provided under Table of Contents (item 3 and 4)

  5. Removal of polonium contamination by lead-bismuth eutectic in nuclear systems

    International Nuclear Information System (INIS)

    Miura, Terumitsu; Obara, Toru; Sekimoto, Hiroshi

    2003-01-01

    Lead-Bismuth eutectic (LBE) is considered as a promising candidate of the coolant of liquid metal cooled fast reactor, and the coolant and/or target of accelerator driven system. LBE has various good characters for coolant, but it has also some problems such as polonium production. It is necessary to take polonium contamination into consideration, when LBE is used as the coolant. In the present paper, the removal of contaminating polonium from material surface is studied. Baking method is investigated for polonium removal from contaminated quartz glass plate in vacuum. Before and after baking, the mass of the contaminants on the surface and alpha particle counts from contaminated surface is measured. When the contaminated quartz glass plates are baked at more than 400degC for a few minutes, alpha particle counts from the surface decreases by more than 99.7%, and the mass of contaminants decreases by more than 50%. When the baking was performed at 300degC for 15 minutes and more, alpha particle count decreases by more than 80%, and the mass decreases in little. When, the baking temperature is lower than 200degC, alpha particle counts and mass do not decrease. (author)

  6. Removal of inorganic As5+ from a small drinking water system

    Directory of Open Access Journals (Sweden)

    MARJANA SIMONIC

    2009-01-01

    Full Text Available The drinking water from a small drinking water system contained arsenic in a concentration of about 50 μg/L. Chemical analyses showed that the pentavalent form of arsenic was present. Since the MCL value is 10 μg/L, it was necessary to implement a technological treatment to make the water suitable for drinking. In order to do so, two technologies were suggested: activated alumina and a-FeOOH (TehnoArz, TA adsorption media. Experiments using both adsorption media were performed on a laboratory scale. It was possible to remove arsenic to below 1 μg/L. The maximal adsorption capacity was found to be 12.7 mg of As5+ per gram of a-FeOOH. Moreover, all the important physico–chemical parameters of the water remained practically unchanged after the treatment. Only a slight release of iron from the media was observed. The Fe–As bond was studied by means of chemical analysis and X-ray powder diffraction. Finally, in addition to showing the capability of arsenic removal by a-FeOOH, a comprehensive optimization of the technological parameters of the selected technology is provided.

  7. A system for removing both oxygen and nitrogen from a rare gas-hydrocarbon mixture

    International Nuclear Information System (INIS)

    Dijkman, W.H.

    1989-01-01

    A study has been made how to remove nitrogen from a mixture of a rare gas and a hydrocarbon in addition to the removal of oxygen, H 2 O and gaseous oxides. The purpose was to find a simple method for the purification of drift-chamber gases in a recirculation system. Such a method would reduce the operating costs of the large detectors presently constructed for LEP. A promising technique has been developed. First results of a chemical reactor using the novel technique are presented. The N 2 content of Ar/air mixtures containing up to 28% air could be reduced to a level of 20 ppm at a flow rate of 0.11 m 3 /h (200 ppm at 1.0 m 3 /h); and the O 2 content to 30 and 300 ppm respectively. Water and gaseous oxides concentrations were always below 5 ppm. Some of the practical problems still to be solved are discussed and suggestions are given for further development and applications. The method can in principle be of more general use. (orig.)

  8. Biotransformation of trace organic compounds by activated sludge from a biological nutrient removal treatment system.

    Science.gov (United States)

    Inyang, Mandu; Flowers, Riley; McAvoy, Drew; Dickenson, Eric

    2016-09-01

    The removal of trace organic compounds (TOrCs) and their biotransformation rates, kb (LgSS(-)(1)h(-)(1)) was investigated across different redox zones in a biological nutrient removal (BNR) system using an OECD batch test. Biodegradation kinetics of fourteen TOrCs with initial concentration of 1-36μgL(-)(1) in activated sludge were monitored over the course of 24h. Degradation kinetic behavior for the TOrCs fell into four groupings: Group 1 (atenolol) was biotransformed (0.018-0.22LgSS(-)(1)h(-)(1)) under anaerobic, anoxic, and aerobic conditions. Group 2 (meprobamate and trimethoprim) biotransformed (0.01-0.21LgSS(-)(1)h(-)(1)) under anoxic and aerobic conditions, Group 3 (DEET, gemfibrozil and triclosan) only biotransformed (0.034-0.26LgSS(-)(1)h(-)(1)) under aerobic conditions, and Group 4 (carbamazepine, primidone, sucralose and TCEP) exhibited little to no biotransformation (<0.001LgSS(-)(1)h(-)(1)) under any redox conditions. BNR treatment did not provide a barrier against Group 4 compounds. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Hair and bare skin discrimination for laser-assisted hair removal systems.

    Science.gov (United States)

    Cayir, Sercan; Yetik, Imam Samil

    2017-07-01

    Laser-assisted hair removal devices aim to remove body hair permanently. In most cases, these devices irradiate the whole area of the skin with a homogenous power density. Thus, a significant portion of the skin, where hair is not present, is burnt unnecessarily causing health risks. Therefore, methods that can distinguish hair regions automatically would be very helpful avoiding these unnecessary applications of laser. This study proposes a new system of algorithms to detect hair regions with the help of a digital camera. Unlike previous limited number of studies, our methods are very fast allowing for real-time application. Proposed methods are based on certain features derived from histograms of hair and skin regions. We compare our algorithm with competing methods in terms of localization performance and computation time and show that a much faster real-time accurate localization of hair regions is possible with the proposed method. Our results show that the algorithm we have developed is extremely fast (around 45 milliseconds) allowing for real-time application with high accuracy hair localization ( 96.48 %).

  10. Removal of nalidixic acid and its degradation products by an integrated MBR-ozonation system.

    Science.gov (United States)

    Pollice, A; Laera, G; Cassano, D; Diomede, S; Pinto, A; Lopez, A; Mascolo, G

    2012-02-15

    Chemical-biological degradation of a widely spread antibacterial (nalidixic acid) was successfully obtained by an integrated membrane bioreactor (MBR)-ozonation process. The composition of the treated solution simulated the wastewater from the production of the target pharmaceutical, featuring high salinity and a relevant concentration of sodium acetate. Aim of treatment integration was to exploit the synergistic effects of chemical oxidation and bioprocesses, by adopting the latter to remove most of the COD and the ozonation biodegradable products. Integration was achieved by placing ozonation in the recirculation stream of the bioreactor effluent. The recirculation flow rate was three-fold the MBR feed, and the performance of the integrated system was compared to the standard polishing configuration (single ozonation step after the MBR). Results showed that the introduction of the ozonation step did not cause relevant drawbacks to both biological and filtration processes. nalidixic acid passed undegraded through the MBR and was completely removed in the ozonation step. Complete degradation of most of the detected ozonation products was better achieved with the integrated MBR-ozonation process than using the sequential treatment configuration, i.e. ozone polishing after MBR, given the same ozone dosage. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Full-scale radium-removal system for a small community. Research report, 1 October 1985-30 September 1987

    International Nuclear Information System (INIS)

    Lauch, R.P.; Mangelson, K.A.

    1988-08-01

    A radium-removal treatment plant was constructed for the small community of Redhill Forest in the central mountains of Colorado. The plant consists of iron removal using oxidation, filtration, and settling; radium and hardness removal using ion exchange; and radium removal from the waste brine using Dow Chemical Company's Radium Selective Complexer (RSC). The raw water comes from deep wells and has naturally occuring radium and iron concentrations of about 30-40 pC/L and 7-10 mg/L, respectively, and is aerated before entering the main treatment plant to remove radon gas and carbon dioxide. A unique feature of the plant is the process that removes radium from the waste brine. The process removes only radium from the spent ion-exchange regeneration water by permanently complexing the radium on the RSC. The RSC is replaced when exhausted and sent to a final disposal site that is acceptable to state regulatory agencies. The overall plant reduces radium from about 35 pCi/L to less than 4 pCi/L. The RSC system has consistently removed over 99% of the radium from the spent ion exchange regenerant. The average inflow radium concentration to the RSC was about 1180 pCi/L, and the average effluent was about 9 pCi/L

  12. Multi-column adsorption systems with condenser for tritiated water vapor removal

    International Nuclear Information System (INIS)

    Kotoh, Kenji; Kudo, Kazuhiko

    1996-01-01

    Two types of multi-column adsorption system are proposed as the system for removal of tritiated moisture from tritium process gases or/and handling room atmospheres. The types are of recycle use of adsorption columns, and are composed of twin or triplet columns and one condenser which is used for collecting the adsorbed moisture from columns in desorption process. The systems utilize the dry gas from a working column as the purge gas for regenerating a saturated column and appropriate an active column for recovery of the tritiated moisture passing through the condenser. Each column hence needs the additional amount of adsorbent for collecting the moisture from the condenser. In the modeling and design of an adsorption column, it is primary to estimate the necessary amount of a candidate adsorbent for its packed-bed. The performance of the proposed systems is examined here by analyzing the dependence of the necessary amount of adsorbent for their columns on process operational conditions and adsorbent moisture-adsorption characteristics. The result shows that the necessary amount is sensitive to the types of adsorption isotherm, and suggests that these systems should employ adsorbents which exhibit the Langmuir-type isotherms. (author)

  13. Copper and zinc removal from roof runoff: from research to full-scale adsorber systems.

    Science.gov (United States)

    Steiner, M; Boller, M

    2006-01-01

    Large, uncoated copper and zinc roofs cause environmental problems if their runoff is infiltrated into the underground or discharged into receiving waters. Since source control is not always feasible, barrier systems for efficient copper and zinc removal are recommended in Switzerland. During the last few years, research carried out in order to test the performance of GIH-calcite adsorber filters as a barrier system. Adsorption and mass transport processes were assessed and described in a mathematical model. However, this model is not suitable for practical design, because it does not give explicit access to design parameters such as adsorber diameter and adsorber bed depth. Therefore, for e.g. engineers, an easy to use design guideline for GIH-calcite adsorber systems was developed, mainly based on the mathematical model. The core of this guideline is the design of the depth of the GIH-calcite adsorber layer. The depth is calculated by adding up the GIH depth for sorption equilibrium and the depth for the mass transfer zone (MTZ). Additionally, the arrangement of other adsorber system components such as particle separation and retention volume was considered in the guideline. Investigations of a full-scale adsorber confirm the successful application of this newly developed design guideline for the application of GIH-calcite adsorber systems in practice.

  14. Nitrogen removal in the bioreactor landfill system with intermittent aeration at the top of landfilled waste

    International Nuclear Information System (INIS)

    He Ruo; Shen Dongsheng

    2006-01-01

    High ammonia concentration of recycled landfill leachate makes it very difficult to treat. In this work, a vertical aerobic/anoxic/anaerobic lab-scale bioreactor landfill system, which was constructed by intermittent aeration at the top of landfilled waste, as a bioreactor for in situ nitrogen removal was investigated during waste stabilization. Intermittent aeration at the top of landfilled waste might stimulate the growth of nitrifying bacteria and denitrifying bacteria in the top and middle layers of waste. The nitrifying bacteria population for the landfill bioreactor with intermittent aeration system reached between10 6 and 10 8 cells/dry g waste, although it decreased 2 orders of magnitude on day 30, due to the inhibitory effect of the acid environment and high organic matter in the landfilled waste. The denitrifying bacteria population increased by between 4 and 13 orders of magnitude compared with conventional anaerobic landfilled waste layers. Leachate NO 3 - -N concentration was very low in both two experimental landfill reactors. After 105 days operation, leachate NH 4 + -N and TN concentrations for the landfill reactor with intermittent aeration system dropped to 186 and 289 mg/l, respectively, while they were still kept above 1000 mg/l for the landfill reactor without intermittent aerobic system. In addition, there is an increase in the rate of waste stabilization as well as an increase of 12% in the total waste settlement for the landfill reactor with intermittent aeration system

  15. Granulated Bog Iron Ores as Sorbents in Passive (BioRemediation Systems for Arsenic Removal

    Directory of Open Access Journals (Sweden)

    Klaudia Debiec

    2018-03-01

    Full Text Available The main element of PbRS (passive (bioremediation systems are sorbents, which act as natural filters retaining heavy metals and carriers of microorganisms involved in water treatment. Thus, the effectiveness of PbRS is determined by the quality of the (adsorbents, which should be stable under various environmental conditions, have a wide range of applications and be non-toxic to (microorganisms used in these systems. Our previous studies showed that bog iron ores (BIOs meet these requirements. However, further investigation of the physical and chemical parameters of BIOs under environmental conditions is required before their large-scale application in PbRS. The aim of this study was (i to investigate the ability of granulated BIOs (gBIOs to remove arsenic from various types of contaminated waters, and (ii to estimate the application potential of gBIOs in technologies dedicated to water treatment. These studies were conducted on synthetic solutions of arsenic and environmental samples of arsenic contaminated water using a set of adsorption columns filled with gBIOs. The experiments performed in a static system revealed that gBIOs are appropriate arsenic and zinc adsorbent. Dynamic adsorption studies confirmed these results and showed, that the actual sorption efficiency of gBIOs depends on the adsorbate concentration and is directly proportional to them. Desorption analysis showed that As-loaded gBIOs are characterized by high chemical stability and they may be reused for the (adsorption of other elements, i.e., zinc. It was also shown that gBIOs may be used for remediation of both highly oxygenated waters and groundwater or settling ponds, where the oxygen level is low, as both forms of inorganic arsenic (arsenate and arsenite were effectively removed. Arsenic concentration after treatment was <100 μg/L, which is below the limit for industrial water.

  16. Granulated bog iron ores as sorbents in passive (bio)remediation systems for arsenic removal

    Science.gov (United States)

    Debiec, Klaudia; Rzepa, Grzegorz; Bajda, Tomasz; Uhrynowski, Witold; Sklodowska, Aleksandra; Krzysztoforski, Jan; Drewniak, Lukasz

    2018-03-01

    The main element of PbRS (passive (bio)remediation systems) are sorbents, which act as natural filters retaining heavy metals and carriers of microorganisms involved in water treatment. Thus, the effectiveness of PbRS is determined by the quality of the (ad)sorbents, which should be stable under various environmental conditions, have a wide range of applications and be non-toxic to (micro)organisms used in these systems. Our previous studies showed that bog iron ores (BIOs) meet these requirements. However, further investigation of the physical and chemical parameters of BIOs under environmental conditions is required before their large-scale application in PbRS. The aim of this study was (i) to investigate the ability of granulated BIOs (gBIOs) to remove arsenic from various types of contaminated waters, and (ii) to estimate the application potential of gBIOs in technologies dedicated to water treatment. These studies were conducted on synthetic solutions of arsenic and environmental samples of arsenic contaminated water using a set of adsorption columns filled with gBIOs. The experiments performed in a static system revealed that gBIOs are appropriate arsenic and zinc adsorbent. Dynamic adsorption studies confirmed these results and showed that the actual sorption efficiency of gBIOs depends on the adsorbate concentration and is directly proportional to them. Desorption analysis showed that As-loaded gBIOs are characterized by high chemical stability and they may be reused for the (ad)sorption of other elements, i.e. zinc. It was also shown that gBIOs may be used for remediation of both highly oxygenated waters and groundwater or settling ponds, where the oxygen level is low, as both forms of inorganic arsenic (arsenate and arsenite) were effectively removed. Arsenic concentration after treatment was <100 µg/L, which is below the limit for industrial water.

  17. Effectiveness of seawater reverse osmosis (SWRO) pretreatment systems in removing transparent exopolymer particles (TEP) substances

    KAUST Repository

    Lee, Shang-Tse

    2015-05-01

    Transparent exopolymer particles (TEP) have been reported as one of the main factors of membrane fouling in seawater reverse osmosis (SWRO) process. Research has been focused on algal TEP so far, overlooking bacterial TEP. This thesis investigated the effects of coagulation on removal of bacterial TEP/TEP precursors in seawater and subsequent reduction on TEP fouling in ultrafiltration (UF), as a pretreatment of SWRO. Furthermore, the performance of pretreatment (coagulation + UF) has been investigated on a bench-scale SWRO system. TEP/TEP precursors were harvested from a strain of marine bacteria, Pseudoalteromonas atlantica, isolated from the Red Sea. Isolated bacterial organic matter (BOM), containing 1.5 mg xanthan gum eq./L TEP/TEP precursors, were dosed in Red Sea water to mimic a high TEP concentration event. Bacterial TEP/TEP precursors added to seawater were coagulated with ferric chloride and aluminum sulfate at different dosages and pH. Results showed that ferric chloride had a better removal efficiency on TEP/TEP precursors. Afterwards, the non-coagulated/coagulated seawater were tested on a UF system at a constant flux of 130 L/m2h, using two types of commercially available membranes, with pore sizes of 50 kDa and 100 kDa, respectively. The fouling potential of coagulated water was determined by the Modified Fouling Index (MFI-UF). Transmembrane pressure (TMP) was also continuously monitored to investigate the fouling development on UF membranes. TEP concentrations in samples were determined by the alcian blue staining assay. Liquid chromatography-organic carbon detection (LC-OCD) was used to determine the removal of TEP precursors with particular emphasis on biopolymers. Finally, SWRO tests showed that TEP/TEP precursors had a high fouling potential as indicated by MFI-UF, corresponding to the TMP measurements. Coagulation could substantially reduce TEP/TEP precursors fouling in UF when its dosage was equal or higher than 0.2 mg Fe/L. The flux decline

  18. Long-term population dynamics and in situ physiology in activated sludge systems with enhanced biological phosphorus removal operated with and without nitrogen removal

    DEFF Research Database (Denmark)

    Lee, N.; Nielsen, P.H.; Aspegren, H.

    2003-01-01

    . However, we observed a lower correlation (0.9). The Actinobacteria were the only additional group of bacteria which showed a similar degree of correlation to the P content in activated sludge as the Rhodocyclus-related bacteria - but only for the system without nitrogen removal. Significant amounts (less...... of the Betaproteobacteria (part of them identified as Rhodocyclus-related bacteria) as well as the Actinobacteria were able to take up P-33(i), [H-3]-acetate and [H-3]-glucose under anaerobic-aerobic conditions. The contribution of anoxic P-33(i) uptake under alternating anaerobic-anoxic conditions was significantly lower...

  19. Removal time and efficacy of Riddell Quick Release Face Guard Attachment System side clips during 1 football season.

    Science.gov (United States)

    Gruppen, Tonia; Smith, Molly; Ganss, Andrea

    2012-01-01

    In the National Athletic Trainers' Association position statement, "Acute Management of the Cervical Spine-Injured Athlete," the technique recommended for face-mask (FM) removal is one that "creates the least head and neck motion, is performed most quickly, is the least difficult, and carries the least chance of failure." Industrial and technological advances in football helmet design and FM attachment systems might influence the efficacy of emergency FM removal. To examine the removal times and success rates of the Quick Release (QR) Face Guard Attachment System (Riddell Sports, Inc, Elyria, OH) throughout and at the conclusion of 1 season of play by a National Collegiate Athletic Association Division III football team competing in the Midwest. Controlled laboratory study. College laboratory. A total of 69 randomly selected Revolution IQ (Riddell Sports, Inc) football helmets fitted with the QR system were used. Each helmet was secured to a spine board, and investigators attempted to remove both of the QR side clips from the helmet with the Riddell insertion tool. Dependent variables included total time for removal of both QR side clips from the FM and success rate for removal of both side clips. The overall success rate for removal of both clips was 94.8% (164/173), whereas the mean times for removal of both clips ranged from 9.92 ± 12.06 seconds to 16.65 ± 20.97 seconds over 4 trial sessions. We found no differences among mean times for trial sessions throughout the season of play among the same helmets or among different helmets (P > .05). Removal time and success rate of the Riddell QR were satisfactory during and after 1 season of play despite use in various temperatures and precipitation.

  20. Removal Time and Efficacy of Riddell Quick Release Face Guard Attachment System Side Clips During 1 Football Season

    Science.gov (United States)

    Gruppen, Tonia; Smith, Molly; Ganss, Andrea

    2012-01-01

    Context In the National Athletic Trainers' Association position statement, “Acute Management of the Cervical Spine-Injured Athlete,” the technique recommended for face-mask (FM) removal is one that “creates the least head and neck motion, is performed most quickly, is the least difficult, and carries the least chance of failure.” Industrial and technological advances in football helmet design and FM attachment systems might influence the efficacy of emergency FM removal. Objective To examine the removal times and success rates of the Quick Release (QR) Face Guard Attachment System (Riddell Sports, Inc, Elyria, OH) throughout and at the conclusion of 1 season of play by a National Collegiate Athletic Association Division III football team competing in the Midwest. Design Controlled laboratory study. Setting College laboratory. Patients or Other Participants A total of 69 randomly selected Revolution IQ (Riddell Sports, Inc) football helmets fitted with the QR system were used. Intervention(s) Each helmet was secured to a spine board, and investigators attempted to remove both of the QR side clips from the helmet with the Riddell insertion tool. Main Outcome Measure(s) Dependent variables included total time for removal of both QR side clips from the FM and success rate for removal of both side clips. Results The overall success rate for removal of both clips was 94.8% (164/173), whereas the mean times for removal of both clips ranged from 9.92 ± 12.06 seconds to 16.65 ± 20.97 seconds over 4 trial sessions. We found no differences among mean times for trial sessions throughout the season of play among the same helmets or among different helmets (P > .05). Conclusions Removal time and success rate of the Riddell QR were satisfactory during and after 1 season of play despite use in various temperatures and precipitation. PMID:22889658

  1. Development of evaluation method for heat removal design of dry storage facilities. pt. 1. Heat removal test on vault storage system of cross flow type

    International Nuclear Information System (INIS)

    Sakamoto, Kazuaki; Koga, Tomonari; Wataru, Masumi; Hattori, Yasuo

    1997-01-01

    The report describes the result of heat removal test of passive cooling vault storage system of cross flow type using 1/5 scale model. Based on a prospect of steady increase in the amount of spent fuel, it is needed to establish large capacity dry storage technologies for spent fuel. Air flow patterns, distributions of air temperature and velocity were measured, by which heat removal characteristics of the system were made clear. Air flow patterns in the storage module depended on the ratio of the buoyant force to the inertial force; the former generated by the difference of air temperatures and the height of the storage module, the latter by the difference of air densities between the outlet of the storage module and ambience and the height of the chimney of the storage facility. A simple method to estimate air flow patterns in the storage module was suggested, where Ri(Richardson) number was applied to represent the ratio. Moreover, heat transfer coefficient from a model of storage tube to cooling air was evaluated, and it was concluded that the generalized expression of heat transfer coefficient for common heat exchangers could be applied to the vault storage system of cross flow type, in which dozens of storage tubes were placed in a storage module. (author)

  2. Removal of Pharmaceutical and Personal Care Products (PPCPs) from Municipal Waste Water with Integrated Membrane Systems, MBR-RO/NF.

    Science.gov (United States)

    Wang, Yonggang; Wang, Xu; Li, Mingwei; Dong, Jing; Sun, Changhong; Chen, Guanyi

    2018-02-05

    This study focuses on the application of combining membrane bioreactor (MBR) treatment with reverse osmosis (RO) or nanofiltration (NF) membrane treatment for removal of pharmaceuticals and personal care products (PPCPs) in municipal wastewater. Twenty-seven PPCPs were measured in real influent with lowest average concentration being trimethoprim (7.12 ng/L) and the highest being caffeine (18.4 ng/L). The results suggest that the MBR system effectively removes the PPCPs with an efficiency of between 41.08% and 95.41%, and that the integrated membrane systems, MBR-RO/NF, can achieve even higher removal rates of above 95% for most of them. The results also suggest that, due to the differences in removal mechanisms of NF/RO membrane, differences of removal rates exist. In this study, the combination of MBR-NF resulted in the removal of 13 compounds to below detection limits and MBR-RO achieved even better results with removal of 20 compounds to below detection limits.

  3. Application of grey model on analyzing the passive natural circulation residual heat removal system of HTR-10

    Institute of Scientific and Technical Information of China (English)

    ZHOU Tao; PENG Changhong; WANG Zenghui; WANG Ruosu

    2008-01-01

    Using the grey correlation analysis, it can be concluded that the reactor pressure vessel wall temperature has the strongest effect on the passive residual heat removal system in HTR (High Temperature gas-cooled Reactor),the chimney height takes the second place, and the influence of inlet air temperature of the chimney is the least. This conclusion is the same as that analyzed by the traditional method. According to the grey model theory, the GM(1,1) and GM(1, 3) model are built based on the inlet air temperature of chimney, pressure vessel temperature and the chimney height. Then the effect of three factors on the heat removal power is studied in this paper. The model plays an important role on data prediction, and is a new method for studying the heat removal power. The method can provide a new theoretical analysis to the passive residual heat removal system of HTR.

  4. The Effect of HLRs on Nitrogen Removal by Using a Pilot-scale Aerated Steel Slag System

    Directory of Open Access Journals (Sweden)

    Hamdan R.

    2017-01-01

    Full Text Available Discharge from domestic wastewater treatment plant amongst the main sources of nitrogen pollution in the environment. However, to remove nitrogen conventionally in domestic wastewater require high cost and complex chemical treatment method. Vertical flow aerated rock filter emerged as one of attractive alternative wastewater treatment method due to simplicity and compactness of the system. However, the application is yet to be developed in warm climate countries in particular Malaysia. Therefore, this study was conducted to investigate the effect of hydraulic loading rate (HLR to the performance of a pilot-scale Vertical Flow Aerated Rock Filter (VFARF in removing nitrogen from domestic wastewater using pilot-scale VFARF systems with steel slag as the filter media. Furthermore, this study has been designed to focus on the effects of two HLRs; 2.72 and 1.04 m3/m3.day. Influent and effluent of the filter systems were monitored biweekly basis for 11 weeks and analyzed for selected parameters. Results from this study shows that the VFARF with HLR 1.04 m3/m3.day has performed better in terms of removal ammonium-nitrogen and TKN as the system able to remove 90.4 ± 6.9%, 86.2 ± 10.7%, whilst the VFARF with 2.72 m3/m3.day remove 87.4 ± 9.9%, 80 ± 11.7%, respectively. From the observation, it can be concluded that nitrogen removal does affect by HLR as the removal in lower HLR system was higher due to high DO level in the VFARF system with 1.04 m3/m3.day which range from 4.5 to 5.1 mg/L whilst the DO level was slightly lower in the VFARF system with 2.72 m3/m3.day in the range of 3.7 to 4.5 mg/L.

  5. Baseline drift effect on the performance of neutron and γ ray discrimination using frequency gradient analysis

    International Nuclear Information System (INIS)

    Liu Guofu; Luo Xiaoliang; Yang Jun; Lin Cunbao; Hu Qingqing; Peng Jinxian

    2013-01-01

    Frequency gradient analysis (FGA) effectively discriminates neutrons and γ rays by examining the frequency-domain features of the photomultiplier tube anode signal. This approach is insensitive to noise but is inevitably affected by the baseline drift similar to other pulse shape discrimination methods. The baseline drift effect is attributed to factors such as power line fluctuation, dark current, noise disturbances, hum, and pulse tail in front-end electronics. This effect needs to be elucidated and quantified before the baseline shift can be estimated and removed from the captured signal. Therefore, the effect of baseline shift on the discrimination performance of neutrons and γ rays with organic scintillation detectors using FGA is investigated in this paper. The relationship between the baseline shift and discrimination parameters of FGA is derived and verified by an experimental system consisting of an americium—beryllium source, a BC501A liquid scintillator detector, and a 5 GSample/s 8-bit oscilloscope. The theoretical and experimental results both show that the estimation of the baseline shift is necessary, and the removal of baseline drift from the pulse shapes can improve the discrimination performance of FGA. (authors)

  6. Process and system for removing sulfur from sulfur-containing gaseous streams

    Science.gov (United States)

    Basu, Arunabha; Meyer, Howard S.; Lynn, Scott; Leppin, Dennis; Wangerow, James R.

    2012-08-14

    A multi-stage UCSRP process and system for removal of sulfur from a gaseous stream in which the gaseous stream, which contains a first amount of H.sub.2S, is provided to a first stage UCSRP reactor vessel operating in an excess SO.sub.2 mode at a first amount of SO.sub.2, producing an effluent gas having a reduced amount of SO.sub.2, and in which the effluent gas is provided to a second stage UCSRP reactor vessel operating in an excess H.sub.2S mode, producing a product gas having an amount of H.sub.2S less than said first amount of H.sub.2S.

  7. Study on heat removal capability concrete cask system with horizontal orientation

    International Nuclear Information System (INIS)

    Nabemoto, Toyonobu; Sakai, Mikio; Fujiwara, Hiroaki; Sakaya, Tadatsugu

    2002-01-01

    In Japan, nuclear fuel cycle, has been promoted, so the recycle fuels formed at nuclear power stations are planned to be processed at reprocessing facilities in future. However, as forming quantities of the recycle fuels are more than reprocessing quantities of the facilities, it is needed to practice a facility (interim storage facility (ISF)) to temporarily store them among the recycle fuels will be reprocessed. The Ishikawajima-Harima Heavy Industries, Co., Ltd. has investigated on vault system and concrete cask system for dry storage system with excellent economical efficiency among various systems on ISFs. As the latter method has a number of actual results in U.S.A., its practice is progressed after some improvements suitable for Japan. When progressing this practice on the latter method on fiscal year 1999, at first, a concrete cask with actual size was experimentally produced, to confirm its productivity. On fiscal year 2000, aiming to establish heat removal evaluation at storage, a thermal load test simulated at the storage was carried out by using this trial product. Here was reported results obtained at a test simulated at repacking carried out on fiscal year 2001. (G.K.)

  8. Centralized Duplicate Removal Video Storage System with Privacy Preservation in IoT.

    Science.gov (United States)

    Yan, Hongyang; Li, Xuan; Wang, Yu; Jia, Chunfu

    2018-06-04

    In recent years, the Internet of Things (IoT) has found wide application and attracted much attention. Since most of the end-terminals in IoT have limited capabilities for storage and computing, it has become a trend to outsource the data from local to cloud computing. To further reduce the communication bandwidth and storage space, data deduplication has been widely adopted to eliminate the redundant data. However, since data collected in IoT are sensitive and closely related to users' personal information, the privacy protection of users' information becomes a challenge. As the channels, like the wireless channels between the terminals and the cloud servers in IoT, are public and the cloud servers are not fully trusted, data have to be encrypted before being uploaded to the cloud. However, encryption makes the performance of deduplication by the cloud server difficult because the ciphertext will be different even if the underlying plaintext is identical. In this paper, we build a centralized privacy-preserving duplicate removal storage system, which supports both file-level and block-level deduplication. In order to avoid the leakage of statistical information of data, Intel Software Guard Extensions (SGX) technology is utilized to protect the deduplication process on the cloud server. The results of the experimental analysis demonstrate that the new scheme can significantly improve the deduplication efficiency and enhance the security. It is envisioned that the duplicated removal system with privacy preservation will be of great use in the centralized storage environment of IoT.

  9. Centralized Duplicate Removal Video Storage System with Privacy Preservation in IoT

    Directory of Open Access Journals (Sweden)

    Hongyang Yan

    2018-06-01

    Full Text Available In recent years, the Internet of Things (IoT has found wide application and attracted much attention. Since most of the end-terminals in IoT have limited capabilities for storage and computing, it has become a trend to outsource the data from local to cloud computing. To further reduce the communication bandwidth and storage space, data deduplication has been widely adopted to eliminate the redundant data. However, since data collected in IoT are sensitive and closely related to users’ personal information, the privacy protection of users’ information becomes a challenge. As the channels, like the wireless channels between the terminals and the cloud servers in IoT, are public and the cloud servers are not fully trusted, data have to be encrypted before being uploaded to the cloud. However, encryption makes the performance of deduplication by the cloud server difficult because the ciphertext will be different even if the underlying plaintext is identical. In this paper, we build a centralized privacy-preserving duplicate removal storage system, which supports both file-level and block-level deduplication. In order to avoid the leakage of statistical information of data, Intel Software Guard Extensions (SGX technology is utilized to protect the deduplication process on the cloud server. The results of the experimental analysis demonstrate that the new scheme can significantly improve the deduplication efficiency and enhance the security. It is envisioned that the duplicated removal system with privacy preservation will be of great use in the centralized storage environment of IoT.

  10. Laboratory tests in support of the MSRE reactive gas removal system

    International Nuclear Information System (INIS)

    Rudolph, J.C.; Del Cul, G.D.; Caja, J.; Toth, L.M.; Williams, D.F.; Thomas, K.S.; Clark, D.E.

    1997-07-01

    The Molten Salt Reactor Experiment (MSRE) at Oak Ridge National Laboratory has been shut down since December 1969, at which time the molten salt mixture of LiF-BeF 2 -ZrF 4 - 233 UF 4 (64.5-30.3-5.0-0.13 mol%) was transferred to fuel salt drain tanks for storage. In the late 1980s, increased radiation in one of the gas lines from the drain tank was attributed to 233 UF 6 . In 1994 two gas samples were withdraw (from a gas line in the Vent House connecting to the drain tanks) and analyzed. Surprisingly, 350 mm Hg of F 2 , 70 mm Hg of UF 6 , and smaller amounts of other gases were found in both of the samples. To remote this gas from above the drain tanks and all of the associated piping, the reactive gas removal system (RGRS) was designed. This report details the laboratory testing of the RGRS, using natural uranium, prior to its implementation at the MSRE facility. The testing was performed to ensure that the equipment functioned properly and was sufficient to perform the task while minimizing exposure to personnel. In addition, the laboratory work provided the research and development effort necessary to maximize the performance of the system. Throughout this work technicians and staff who were to be involved in RGRS operation at the MSRE site worked directly with the research staff in completing the laboratory testing phase. Consequently, at the end of the laboratory work, the personnel who were to be involved in the actual operations had acquired all of the training and experience necessary to continue with the process of reactive gas removal

  11. Waste heat recovery system including a mechanism for collection, detection and removal of non-condensable gas

    Science.gov (United States)

    Ernst, Timothy C.; Zigan, James A.

    2017-06-20

    The disclosure describes a non-condensable gas collection, detection, and removal system for a WHR system that helps to maintain cycle efficiency of the WHR system across the life of an engine system associated with the WHR system. A storage volume is configured to collect non-condensable gas received from the working fluid circuit, and a release valve is configured to selectively release non-condensable gas contained within the storage volume.

  12. First Grade Baseline Evaluation

    Science.gov (United States)

    Center for Innovation in Assessment (NJ1), 2013

    2013-01-01

    The First Grade Baseline Evaluation is an optional tool that can be used at the beginning of the school year to help teachers get to know the reading and language skills of each student. The evaluation is composed of seven screenings. Teachers may use the entire evaluation or choose to use those individual screenings that they find most beneficial…

  13. Design and modeling of an advanced marine machinery system including waste heat recovery and removal of sulphur oxides

    DEFF Research Database (Denmark)

    Frimann Nielsen, Rasmus; Haglind, Fredrik; Larsen, Ulrik

    2014-01-01

    the efficiency of machinery systems. The wet sulphuric acid process is an effective way of removing flue gas sulphur oxides from land-based coal-fired power plants. Moreover, organic Rankine cycles (ORC) are suitable for heat to power conversion for low temperature heat sources. This paper describes the design...... that an ORC placed after the conventional waste heat recovery system is able to extract the sulphuric acid from the exhaust gas, while at the same time increase the combined cycle thermal efficiency by 2.6%. The findings indicate that the technology has potential in marine applications regarding both energy...... and modeling of a highly efficient machinery system which includes the removal of exhaust gas sulphur oxides. The system consists of a two-stroke diesel engine, the wet sulphuric process for sulphur removal, a conventional steam Rankine cycle and an ORC. Results of numerical modeling efforts suggest...

  14. Evaluation of acrylamide-removing properties of two Lactobacillus strains under simulated gastrointestinal conditions using a dynamic system.

    Science.gov (United States)

    Rivas-Jimenez, L; Ramírez-Ortiz, K; González-Córdova, A F; Vallejo-Cordoba, B; Garcia, H S; Hernandez-Mendoza, A

    2016-09-01

    The aim of this study was to evaluate the capability of Lactobacillus reuteri NRRL 14171 and Lactobacillus casei Shirota to remove dietary acrylamide (AA) under simulated gastrointestinal conditions using a dynamic system. The effects of different AA levels or bacteria concentration on toxin removal by Lactobacillus strains were assessed. Thereafter, AA-removing capability of bacteria strains under either fasting or postprandial simulated gastrointestinal conditions was evaluated. Commercial potato chips were analyzed for their AA content, and then used as a food model. Average AA content (34,162μg/kg) in potato chips exceeded by ca. 34-fold the indicative values recommended by the EU. Toxin removal ability was dependent on AA content and bacterial cell concentration. A reduction on bacterial viability was observed in the food model and at the end of both digestive processes evaluated. However, bacteria survived in enough concentrations to remove part of the toxin (32-73%). Both bacterial strains were able to remove AA under different simulated gastrointestinal conditions, being L. casei Shirota the most effective (ca. 70% removal). These findings confirmed the risk of potato chips as dietary AA exposure for consumers, and that strains of the genus Lactobacillus could be employed to reduce the bioavailability of dietary AA. Copyright © 2016 Elsevier GmbH. All rights reserved.

  15. Reliability and Maintainability Analysis for the Amine Swingbed Carbon Dioxide Removal System

    Science.gov (United States)

    Dunbar, Tyler

    2016-01-01

    I have performed a reliability & maintainability analysis for the Amine Swingbed payload system. The Amine Swingbed is a carbon dioxide removal technology that has gone through 2,400 hours of International Space Station on-orbit use between 2013 and 2016. While the Amine Swingbed is currently an experimental payload system, the Amine Swingbed may be converted to system hardware. If the Amine Swingbed becomes system hardware, it will supplement the Carbon Dioxide Removal Assembly (CDRA) as the primary CO2 removal technology on the International Space Station. NASA is also considering using the Amine Swingbed as the primary carbon dioxide removal technology for future extravehicular mobility units and for the Orion, which will be used for the Asteroid Redirect and Journey to Mars missions. The qualitative component of the reliability and maintainability analysis is a Failure Modes and Effects Analysis (FMEA). In the FMEA, I have investigated how individual components in the Amine Swingbed may fail, and what the worst case scenario is should a failure occur. The significant failure effects are the loss of ability to remove carbon dioxide, the formation of ammonia due to chemical degradation of the amine, and loss of atmosphere because the Amine Swingbed uses the vacuum of space to regenerate the Amine Swingbed. In the quantitative component of the reliability and maintainability analysis, I have assumed a constant failure rate for both electronic and nonelectronic parts. Using this data, I have created a Poisson distribution to predict the failure rate of the Amine Swingbed as a whole. I have determined a mean time to failure for the Amine Swingbed to be approximately 1,400 hours. The observed mean time to failure for the system is between 600 and 1,200 hours. This range includes initial testing of the Amine Swingbed, as well as software faults that are understood to be non-critical. If many of the commercial parts were switched to military-grade parts, the expected

  16. Computer based plant display and digital control system of Wolsong NPP Tritium Removal Facility

    International Nuclear Information System (INIS)

    Jung, C.; Smith, B.; Tosello, G.; Grosbois, J. de; Ahn, J.

    2007-01-01

    The Wolsong Tritium Removal Facility (WTRF) is an AECL-designed, first-of-a-kind facility that removes tritium from the heavy water that is used in systems of the CANDUM reactors in operation at the Wolsong Nuclear Power Plant in South Korea. The Plant Display and Control System (PDCS) provides digital plant monitoring and control for the WTRF and offers the advantages of state-of-the-art digital control system technologies for operations and maintenance. The overall features of the PDCS will be described and some of the specific approaches taken on the project to save construction time and costs, to reduce in-service life-cycle costs and to improve quality will be presented. The PDCS consists of two separate computer sub-systems: the Digital Control System (DCS) and the Plant Display System (PDS). The PDS provides the computer-based Human Machine Interface (HMI) for operators, and permits efficient supervisory or device level monitoring and control. A System Maintenance Console (SMC) is included in the PDS for the purpose of software and hardware configuration and on-line maintenance. A Historical Data System (HDS) is also included in the PDS as a data-server that continuously captures and logs process data and events for long-term storage and on-demand selective retrieval. The PDCS of WTRF has been designed and implemented based on an off-the-self PDS/DCS product combination, the Delta-V System from Emerson. The design includes fully redundant Ethernet network communications, controllers, power supplies and redundancy on selected I/O modules. The DCS provides field bus communications to interface with 3rd party controllers supplied on specialized skids, and supports HART communication with field transmitters. The DCS control logic was configured using a modular and graphical approach. The control strategies are primarily device control modules implemented as autonomous control loops, and implemented using IEC 61131-3 Function Block Diagram (FBD) and Structured

  17. A novel pump-driven veno-venous gas exchange system during extracorporeal CO2-removal.

    Science.gov (United States)

    Hermann, Alexander; Riss, Katharina; Schellongowski, Peter; Bojic, Andja; Wohlfarth, Philipp; Robak, Oliver; Sperr, Wolfgang R; Staudinger, Thomas

    2015-10-01

    Pump-driven veno-venous extracorporeal CO2-removal (ECCO2-R) increasingly takes root in hypercapnic lung failure to minimize ventilation invasiveness or to avoid intubation. A recently developed device (iLA activve(®), Novalung, Germany) allows effective decarboxylation via a 22 French double lumen cannula. To assess determinants of gas exchange, we prospectively evaluated the performance of ECCO2-R in ten patients receiving iLA activve(®) due to hypercapnic respiratory failure. Sweep gas flow was increased in steps from 1 to 14 L/min at constant blood flow (phase 1). Similarly, blood flow was gradually increased at constant sweep gas flow (phase 2). At each step gas transfer via the membrane as well as arterial blood gas samples were analyzed. During phase 1, we observed a significant increase in CO2 transfer together with a decrease in PaCO2 levels from a median of 66 mmHg (range 46-85) to 49 (31-65) mmHg from 1 to 14 L/min sweep gas flow (p gas flow rates. During phase 2, oxygen transfer significantly increased leading to an increase in PaO2 from 67 (49-87) at 0.5 L/min to 117 (66-305) mmHg at 2.0 L/min (p gas flow results in effective CO2-removal, which can be further reinforced by raising blood flow. The clinically relevant oxygenation effect in this setting could broaden the range of indications of the system and help to set up an individually tailored configuration.

  18. Removal of fecal indicators and pathogens in a waste stabilization pond system treating municipal wastewater in India.

    Science.gov (United States)

    Tyagi, Vinay Kumar; Kazmi, A A; Chopra, A K

    2008-11-01

    This study assess the removal of fecal indicators (i.e., total coliforms, fecal coliforms, E. coli, fecal streptococci, and pathogens [Salmonella sp. and helminth eggs]) in a full-scale facultative and maturation pond system with primary screening and manual grit removal facility. The capacity of the plant is 6 ML/d. The results showed that the system was able to remove approximately 2.0 to 3.5 log units of fecal indicators and almost 100% of helminth eggs. Meanwhile, Salmonella was not eliminated significantly, as only 1.26 log units removal was found. Removal efficiency of fecal indicator bacteria was reported maximum during summers (3.4 to 4.0 log units) and minimum (1.9 to 2.0 log units) in winters. Further efforts were made to seek the correlation between key physicochemical wastewater quality parameters (biochemical oxygen demand, turbidity, and suspended solids) and indicator microorganisms (total coliforms, fecal coliforms, and fecal streptococci). Among all these parameters, suspended solids showed the highest correlation coefficient (r2) with total coliforms (0.79), fecal coliforms (0.78), and fecal streptococci (0.75). These correlations manifest that the improvement of microbiological quality of wastewater is strongly linked to the removal of suspended solids.

  19. Implementation of New System for Oxygen Generation and Carbon Dioxide Removal =

    Science.gov (United States)

    Karavolos, Angelo Peter

    This research effort develops an integrated system for CO2 removal and O2 production. A unique material, dodeca-tungsto-phosphoric acid (H3PO4W12O3; henceforth referred to as DTPA) is mixed with tetra-ethyl-ortho-silicate Si(OC2H 5)4 or TEOS. This mixture exhibits unique properties of heat absorption and high electrical conductivity. In the system described herein, the DTPA resides within a cross linked arrangement of TEOS. The DTPA furnishes a source of O2, while the TEOS furnishes structural support for the large DTPA crystals. In addition, the large amount of H2O within the crystal also adsorbs CO2. It can also be cross-linked with other polymers such as polycarbonate, for different applications and properties such as flexible textiles. A set of isolated bench experiments were designed to test CO2 adsorption, O2 production, heat production, and voltage production were conducted to test the hypothesis that DTPA can provide CO2 adsorption, O2 generation, heat generation and electrical generation. Five experiments with this apparatus were conducted: (1) a mass balance experiment; (2) an X-ray diffraction experiment; (3) a photo spectroscopic experiment; (4) a calorimetric experiment; and (5) a dielectric experiment. Results illustrate that approximately 2880 grams of this material produces 576 grams of O2, and removes 1760 grams of CO2. The reaction also produces approximately 844 kJ/mole heat, and can supply 12.2 V potential over a period of 4.5 hours. The amount of unused material and the recycling ability suggests the usefulness of the technique to achieve between a 50-75% closed system. In addition, an experiment using 18O tracer demonstrated that approximately 20% of the O2 produced comes from processed CO2 adsorbed by the crystal, while the remaining 80% of the O2 produced comes from replaced O2 within the crystal itself. The device has multiple applications including environmental control and life support for aircraft cabins, space vehicle interiors

  20. Design and transient analyses of emergency passive residual heat removal system of CPR1000

    International Nuclear Information System (INIS)

    Zhang, Y.P.; Qiu, S.Z.; Su, G.H.; Tian, W.X.

    2012-01-01

    Highlights: ► Designing an EPRHRs for CPR1000. ► Developing a RELAP model of the EPRHRs. ► The EPRHRs could take away the decay heat effectively. - Abstract: The steam generator secondary emergency passive residual heat removal system (EPRHRs) is a new design for traditional generation II + reactor CPR1000. The EPRHRs is designed to improve the safety and reliability of CPR1000 by completely or partially replacing traditional emergency water cooling system in the event of the station blackout or loss of heat sink accident. The EPRHRs consists of steam generator (SG), heat exchanger (HX), emergency makeup tank (EMT), cooling water tank (CWT), and corresponding pipes and valves. In order to improve the safety and reliability of CPR1000, the model of the primary loop and the EPRHRs was developed to investigate residual heat removal capability of the EPRHRs and the transient characteristics of the primary loop affected by the EPRHRs using RELAP5/MOD3.4. The transient characteristics of the primary loop and the EPRHRs were calculated in the event of station blackout accident. Sensitivity studies of the EPRHRs were also conducted to investigate the response of the primary loop and the EPRHRs on the main parameters of the EPRHRs. The EPRHRs could supply water to the SG shell side from the EMT successfully. The calculation results showed that the EPRHRs could take away the decay heat from the primary loop effectively, and that the single-phase and two-phase natural circulations were established in the primary loop and EPRHRs loop, respectively. The results also indicated that the effect of isolation valve open time on the transient characteristics of the primary loop was little. However, the effect of isolation valve open time on the EPRHRs condensate flow was relatively greater. The isolation valves should not be opened too rapidly during the isolation valve opening process, and the isolation valve opening time should be greater than 10 s, which could avoid the

  1. Radium removal for a small community water-supply system. Research report, 1 October 1985-30 September 1987

    International Nuclear Information System (INIS)

    Mangelson, K.A.

    1988-07-01

    In 1984, a radium-removal treatment plant was constructed for the small community of Redhill Forest located in the central mountains of Colorado. The treatment plant consists of a process for removing iron and manganese ahead of an ion-exchange process for the removal of radium. The raw water comes from deep wells and has naturally occurring radium and iron concentrations of about 30-40 pCi/L and 7-10 mg/L, respectively. Before the raw water enters the main treatment plant, the raw water is aerated to remove radon gas and carbon dioxide. The unique features of the Redhill Forest Treatment Plant are related to the ways in which the radium removed from the raw water is further treated and eventually disposed of as treatment plant waste. A separate system removes only radium from the backwash/regeneration water of the ion exchange process and the radium is permanently complexed on a Radium Selective Complexer (RSC) resin made by Dow Chemical. The RSC resin containing radium is replaced with virgin resin as needed and the resin waste transported to a permanent final disposal site in Beatty, NV. This report presents a detailed description of the Redhill Forest treatment system and the results of in-depth monitoring of the processes and other factors relating to the overall operation of the radium-removal system. Included are descriptions of modifications made in the plant operation to improve the overall system operation and of the procedures for final disposal of the RSC resin-containing radium

  2. In-pool energy removal system for emergency operation: experiment and analytical assessment

    International Nuclear Information System (INIS)

    Bianchi, F.; Meloni, P.; Ferri, R.; Achilli, A.

    2003-01-01

    In the framework of a domestic research program on innovative safety systems, ENEA has developed a device, so-called PERSEO, aimed at increasing the reliability of Residual Heat Removal Systems that implement in-pool heat exchangers. This device is suitable to transfer power from the primary side to the pool without the installation of valves on the pressurized loop, thus reducing thermal-mechanical constraints and thermal-hydraulic instabilities. The experiments have been performed at SIET Thermal-hydraulic Research Centre by modifying the existing PANTHERS IC-PCC facility and RELAP5/mod 3.2 and 3.3 beta releases have been run to perform the pre and post-test analyses respectively. The pre-test calculations provided a quantitative representation of the device behaviour and gave interesting indications on the procedures to be adopted for the experiments. The post-test calculations have been compared with the experimental data addressing particular attention to the simulation of three-dimensional effects of water circulation in both the HX and Overall Pool and have confirmed the RELAP5 code capability to fit the experimental data. The paper deals with the activity performed up to now. (author)

  3. Development of dust removal system using static electricity for fusion experimental reactors

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, Masanori; Ueda, Yasutoshi; Oda, Yasushi; Takahashi, Kenji [Mitsubishi Heavy Industries Ltd., Tokyo (Japan); Seki, Yasushi; Aoki, Isao; Ueda, Shuzo; Kurihara, Ryoichi

    1997-11-01

    Tests to collect and transport metallic and non-metallic dust particles have been conducted using static electricity in a vacuum environment to investigate the applicability of a static electricity dust removal system for fusion experimental reactors. The dust particles are charged by electrostatic induction, floated and collected due to the Coulomb force generated by the AC electric field. They are then transported due to the gradient force induced by the electric curtain of the non-uniform travelling-wave electric field. Using a fully insulated electrode with a single-phase AC voltage up to 15 kV, aluminum and carbon dust were successfully collected. The highest collection rates for the aluminum and carbon dust were around 30 and 2 g/min, respectively. The linear-type electrodes, using as high as 22 kV of the three-phase AC voltage, transported aluminum dust up to an angle of 60deg. Applying a guide electrode to the linear-type electrode, the transportation rate was approximately doubled and almost constant at every angle, including a 90deg angle. The system transported aluminum dust up to the rate of 13 g/min. The influence of the 0.15 T magnetic field on the dust collection and transportation efficiencies was found to be negligible. (author)

  4. Development of dust removal system using static electricity for fusion experimental reactors

    International Nuclear Information System (INIS)

    Onozuka, Masanori; Ueda, Yasutoshi; Oda, Yasushi; Takahashi, Kenji; Seki, Yasushi; Aoki, Isao; Ueda, Shuzo; Kurihara, Ryoichi.

    1997-01-01

    Tests to collect and transport metallic and non-metallic dust particles have been conducted using static electricity in a vacuum environment to investigate the applicability of a static electricity dust removal system for fusion experimental reactors. The dust particles are charged by electrostatic induction, floated and collected due to the Coulomb force generated by the AC electric field. They are then transported due to the gradient force induced by the electric curtain of the non-uniform travelling-wave electric field. Using a fully insulated electrode with a single-phase AC voltage up to 15 kV, aluminum and carbon dust were successfully collected. The highest collection rates for the aluminum and carbon dust were around 30 and 2 g/min, respectively. The linear-type electrodes, using as high as 22 kV of the three-phase AC voltage, transported aluminum dust up to an angle of 60deg. Applying a guide electrode to the linear-type electrode, the transportation rate was approximately doubled and almost constant at every angle, including a 90deg angle. The system transported aluminum dust up to the rate of 13 g/min. The influence of the 0.15 T magnetic field on the dust collection and transportation efficiencies was found to be negligible. (author)

  5. Development status of the cryogenic distillation system in Cernavoda Tritium Removal Facility

    International Nuclear Information System (INIS)

    Draghia, Mirela; Ana, George; Pasca, Gheorghe; Porcariu, Florina

    2009-01-01

    Full text: The reference design technology for the heavy water detritiation plant of Cernavoda CANDU station is based on combination of Liquid Phase Catalytic Exchange (LPCE) and Cryogenic Distillation (CD) processes. Based on this technology, tritium is transferred from the heavy water to a deuterium stream in the catalyzed isotopic exchange process, LPCE, followed by a final enrichment within the cryogenic distillation cascade. The final step is the tritium storage on metallic hydride. The basic function of the Cryogenic Distillation System (CDS) is the separation of tritium from the tritiated deuterium coming from the LPCE column in the following conditions: - the final product has to be tritium with a concentration of at least 99%; - it must be provided a detritiation factor of at least 100 (the ration between the tritium concentration in the deuterium stream fed to the CD system and the tritium concentration in the returned stream to the LPCE); - the deuterium must be enriched up to 99.995%, by removing the protium; - provisions for safe discharge of the entire inventory of the CD cascade into buffer vessels shall be implemented. To summarize, the present status of the project consists of technical documentation for all the components of CDS, including the P and ID (Pipping and Instrumentation Diagram), preliminary data sheets, technical specifications, drawings for the major components as the buffer vessels, coldbox, etc, and 3D models as well for almost all the components. (authors)

  6. Long term operation of continuous-flow system with enhanced biological phosphorus removal granules at different COD loading.

    Science.gov (United States)

    Li, Dong; Lv, Yufeng; Zeng, Huiping; Zhang, Jie

    2016-09-01

    In this study, a continuous-flow system with enhanced biological phosphorus removal (EBPR) granules was operated at different COD concentrations (200, 300 and 400mgL(-)(1)) to investigate the effect of COD loading on this system. The results showed that when the COD concentration in influent was increased to 400mgL(-)(1), the anaerobic COD removal efficiency and total phosphorus removal efficiency reduced obviously and the settling ability of granules deteriorated due to the proliferation of filamentous bacteria. Moreover, high COD loading inhibited the EPS secretion and destroyed the stability of granules. Results of high-through pyrosequencing indicated that filamentous bacteria had a competitive advantage over polyphosphate-accumulating organisms (PAOs) at high COD loading. The performance of system, settling ability of granules and proportion of PAOs gradually recovered to the initial level after the COD concentration was reduced to 200mgL(-)(1) on day 81. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Enhanced Cr(VI) removal from groundwater by Fe0-H2O system with bio-amended iron corrosion

    DEFF Research Database (Denmark)

    Yin, Weizhao; Li, Yongtao; Wu, Jinhua

    2017-01-01

    Abstract A one-pot bio-iron system was established to investigate synergetic abiotic and biotic effects between iron and microorganisms on Cr(VI) removal. More diverse iron corrosion and reactive solids, such as green rusts, lepidocrocite and magnetite were found in the bio-iron system than...... transfer on the solid phase. The results also showed that the reduction of Cr(VI) by microorganisms was insignificant, indicating the adsorption/co-precipitation of Cr by iron oxides on iron surface was responsible for the overall Cr(VI) removal. Our study demonstrated that the bio-amended iron corrosion...... in the Fe0-H2O system, leading to 4.3 times higher Cr(VI) removal efficiency in the bio-iron system than in the Fe0-H2O system. The cycling experiment also showed that the Cr(VI) removal capacity of Fe0 in the bio-iron system was 12.4 times higher than that in the Fe0-H2O system. A 62 days of life...

  8. Nonlinear Dynamic Inversion Baseline Control Law: Flight-Test Results for the Full-scale Advanced Systems Testbed F/A-18 Airplane

    Science.gov (United States)

    Miller, Christopher J.

    2011-01-01

    A model reference nonlinear dynamic inversion control law has been developed to provide a baseline controller for research into simple adaptive elements for advanced flight control laws. This controller has been implemented and tested in a hardware-in-the-loop simulation and in flight. The flight results agree well with the simulation predictions and show good handling qualities throughout the tested flight envelope with some noteworthy deficiencies highlighted both by handling qualities metrics and pilot comments. Many design choices and implementation details reflect the requirements placed on the system by the nonlinear flight environment and the desire to keep the system as simple as possible to easily allow the addition of the adaptive elements. The flight-test results and how they compare to the simulation predictions are discussed, along with a discussion about how each element affected pilot opinions. Additionally, aspects of the design that performed better than expected are presented, as well as some simple improvements that will be suggested for follow-on work.

  9. Rationing with baselines

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Moreno-Ternero, Juan D.; Østerdal, Lars Peter Raahave

    2013-01-01

    We introduce a new operator for general rationing problems in which, besides conflicting claims, individual baselines play an important role in the rationing process. The operator builds onto ideas of composition, which are not only frequent in rationing, but also in related problems...... such as bargaining, choice, and queuing. We characterize the operator and show how it preserves some standard axioms in the literature on rationing. We also relate it to recent contributions in such literature....

  10. LTC vacuum blasting machine (concrete): Baseline report

    International Nuclear Information System (INIS)

    1997-01-01

    The LTC shot blast technology was tested and is being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The LTC 1073 Vacuum Blasting Machine uses a high-capacity, direct-pressure blasting system which incorporates a continuous feed for the blast media. The blast media cleans the surface within the contained brush area of the blast. It incorporates a vacuum system which removes dust and debris from the surface as it is blasted. The safety and health evaluation during the testing demonstration focused on two main areas of exposure: dust and noise. Dust exposure during maintenance activities was minimal, but due to mechanical difficulties dust monitoring could not be conducted during operation. Noise exposure was significant. Further testing for each of these exposures is recommended because of the outdoor environment where the testing demonstration took place. This may cause the results to be inaccurate. It is feasible that the dust and noise levels will be higher in an enclosed environment. In addition, other safety and health issues found were ergonomics, heat stress, tripping hazards, electrical hazards, lockout/tagout, and arm-hand vibration

  11. Environmentally friendly technology and equipment of the system of spent FA waste removal for storage at the RT plant

    International Nuclear Information System (INIS)

    Vovkotrub, Yu.G.; Dorokhin, V.I.; Istomin, V.L.; Markov, B.V.; Samokhotov, S.A.

    1999-01-01

    Systems having no world analog for removal and disposal of spent fuel assembly tailings and insoluble fragments of crushed fuel element claddings, which have been put into service at radiotechnical plant of Mayak PA, are described. The tailings are brought to a repository by a dolly moving inside a piping (box) using linear asynchronous electric motors, while insoluble fragments are removed via the piping using pulsed pneumatic transportation. It is pointed out that the systems described comply with today's requirements in terms of environmental protection and creation of conditions favorable for the personnel work [ru

  12. Reliability analysis of 2400 MWth gas-cooled fast reactor natural circulation decay heat removal system

    International Nuclear Information System (INIS)

    Marques, M.; Bassi, C.; Bentivoglio, F.

    2012-01-01

    In support to a PSA (Probability Safety Assessment) performed at the design level on the 2400 MWth Gas-cooled Fast Reactor, the functional reliability of the decay heat removal system (DHR) working in natural circulation has been estimated in two transient situations corresponding to an 'aggravated' Loss of Flow Accident (LOFA) and a Loss of Coolant Accident (LOCA). The reliability analysis was based on the RMPS methodology. Reliability and global sensitivity analyses use uncertainty propagation by Monte Carlo techniques. The DHR system consists of 1) 3 dedicated DHR loops: the choice of 3 loops (3*100% redundancy) is made in assuming that one could be lost due to the accident initiating event (break for example) and that another one must be supposed unavailable (single failure criterion); 2) a metallic guard containment enclosing the primary system (referred as close containment), not pressurized in normal operation, having a free volume such as the fast primary helium expansion gives an equilibrium pressure of 1.0 MPa, in the first part of the transient (few hours). Each dedicated DHR loop designed to work in forced circulation with blowers or in natural circulation, is composed of 1) a primary loop (cross-duct connected to the core vessel), with a driving height of 10 meters between core and DHX mid-plan; 2) a secondary circuit filled with pressurized water at 1.0 MPa (driving height of 5 meters for natural circulation DHR); 3) a ternary pool, initially at 50 C. degrees, whose volume is determined to handle one day heat extraction (after this time delay, additional measures are foreseen to fill up the pool). The results obtained on the reliability of the DHR system and on the most important input parameters are very different from one scenario to the other showing the necessity for the PSA to perform specific reliability analysis of the passive system for each considered scenario. The analysis shows that the DHR system working in natural circulation is

  13. E-Bra system for women ECG measurement with GPRS communication, Nanosensor, and motion artifact remove algorithm

    Science.gov (United States)

    Kwon, Hyeokjun; Oh, Sechang; Kumar, Prashanth S.; Varadan, Vijay K.

    2012-10-01

    with conductive gel. However, the gel can be dried when taking long time monitoring. The gold nanowire structure electrodes without consideration of uncomfortable usage of gel are attached on beneath the chest position of a brassiere, and the electrodes convert the physical ECG signal to voltage potential signal. The voltage potential ECG signal is converted to digital signal by AD converter included in microprocessor. The converted ECG signal by AD converter is saved on every 1 sec period in the internal RAM in microprocessor. For transmission of the saved data in the internal RAM to a server computer locating at remote area, the system uses the GPRS communication technology, which can develop the wide area network(WAP) without any gateway and repeater. In addition, the transmission system is operated on client mode of GPRS communication. The remote server is installed a program including the functions of displaying and analyzing the transmitted ECG. To display the ECG data, the program is operated with TCP/IP server mode and static IP address, and to analyze the ECG data, the paper suggests motion artifact remove algorithm including adaptive filter with LMS(least mean square), baseline detection algorithm using predictability estimation theory, a filter with moving weighted factor, low pass filter, peak to peak detection, and interpolation.

  14. Impact of carbon-dosing on micro-pollutants removal in MBBR post-denitrification systems

    DEFF Research Database (Denmark)

    Escola Casas, Monica; Torresi, Elena; Plósz, Benedek G.

    and indigenous micro-pollutants concentrations, different methanol and ethanol dosages were used to manipulate the carbon-to-nitrate ratio in two MBBRs. Atenolol, citalopram and trimethoprim were efficiently removed in both reactors. However, type or concentration of carbon did not correlate to micro......-pollutant removal rates. Second, an anoxic-batch test with spiked micropollutants was conducted. The batch test showed that acetyl-sulfadiazine, atenolol, citalopram, propranolol and trimethoprim were easily removed in both reactors. Ibuprofen, clarithromycin, iopromide, metoprolol, iohexol, iomeprol, venlafaxine......, erythromycin and sotalol were moderately removed while diatrizoic acid, iopamidol, carbamazepine and diclofenac showed to be hardly biodegradable. The fact that both reactors gave similar removal rate constants for easily degradable compounds, could suggest that diffusion through the biofilm determined...

  15. Demonstration of radionuclides removal at the 105-N basin using the 3M system

    International Nuclear Information System (INIS)

    Hobart, S.A.; Hyman, M.

    1996-03-01

    A field demonstration of the Minnesota Mining and Manufacturing Company (3M) innovative Cs- and Sr-removal technology was undertaken to support deactivation of the Hanford Site's N Reactor. The field demonstration and laboratory studies performed by Pacific Northwest National Laboratory are documented in this report. The deactivation of N Reactor includes an aggressive schedule for removing water from the reactor's original fuel storage pool, known as N Basin. The plan for treating N Basin water involves particulate filtration, followed by further treatment at the Hanford Site's Effluent Treatment Facility (ETF) before the water is discharged to a permitted soil column. Prudence calls for developing a backup treatment plan in the event that ETF is not available to support the N Basin critical path schedule. The 3M technique uses membrane filters that are impregnated with chemical species to remove specific ions from water by ion exchange or selective reaction. Sodium titanate is used to remove Sr by ion exchange, and potassium-cobalt hexacyanoferrate (COHEX) is used to remove Cs by formation of cesium-cobalt ferrocyanide. As a result of this field test, the following recommendations are made: 3M technology should not be considered for removing Sr from N Basin water, although the technology merits consideration for Sr removal in waters that have relatively low Cs content; application of 3M technology by recirculation of basin water through 3M adsorption cartridges for removal of Cs-137 should be considered since it efficiently removes Cs and may be cost effective; additional pilot-scale tests should be performed to determine the capacity of COHEX for Cs-137 removal, if full-scale application is desired

  16. Baseline monitoring and simulated liquid release test report for Tank W-9, Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1997-08-01

    This document provides the Environmental Restoration Program with the baseline dry well conductivity monitoring data and simulated liquid release tests to support the use of Gunite and Associated Tank (GAAT) W-9 as a temporary consolidation tank during waste removal operations. Information provided in this report forms part of the technical basis for criticality safety, systems safety, engineering design and waste management as they apply to the GAAT treatability study and waste removal actions

  17. Bioremediation 3.0: Engineering pollutant-removing bacteria in the times of systemic biology.

    Science.gov (United States)

    Dvořák, Pavel; Nikel, Pablo I; Damborský, Jiří; de Lorenzo, Víctor

    2017-11-15

    Elimination or mitigation of the toxic effects of chemical waste released to the environment by industrial and urban activities relies largely on the catalytic activities of microorganisms-specifically bacteria. Given their capacity to evolve rapidly, they have the biochemical power to tackle a large number of molecules mobilized from their geological repositories through human action (e.g., hydrocarbons, heavy metals) or generated through chemical synthesis (e.g., xenobiotic compounds). Whereas naturally occurring microbes already have considerable ability to remove many environmental pollutants with no external intervention, the onset of genetic engineering in the 1980s allowed the possibility of rational design of bacteria to catabolize specific compounds, which could eventually be released into the environment as bioremediation agents. The complexity of this endeavour and the lack of fundamental knowledge nonetheless led to the virtual abandonment of such a recombinant DNA-based bioremediation only a decade later. In a twist of events, the last few years have witnessed the emergence of new systemic fields (including systems and synthetic biology, and metabolic engineering) that allow revisiting the same environmental pollution challenges through fresh and far more powerful approaches. The focus on contaminated sites and chemicals has been broadened by the phenomenal problems of anthropogenic emissions of greenhouse gases and the accumulation of plastic waste on a global scale. In this article, we analyze how contemporary systemic biology is helping to take the design of bioremediation agents back to the core of environmental biotechnology. We inspect a number of recent strategies for catabolic pathway construction and optimization and we bring them together by proposing an engineering workflow. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Removal of COD, phenols and ammonium from Lurgi coal gasification wastewater using A2O-MBR system

    International Nuclear Information System (INIS)

    Wang, Zixing; Xu, Xiaochen; Gong, Zheng; Yang, Fenglin

    2012-01-01

    Highlights: ► Anaerobic–anoxic–aerobic MBR system treated the coal gasification wastewater. ► COD removal rate was 97.4% with effluent concentration less than 100 mg/L. ► NH 4 + -N removal rate was 92.8% with effluent concentration less than 12 mg/L. ► HRT and recycle ratio strongly affected the performance of the system. ► GC/MS analysis found refractory organic removal in anaerobic and anoxic stage. - Abstract: As a typical industrial wastewater, coal gasification wastewater has poor biodegradability and high toxicity. In this paper, a laboratory-scale anaerobic–anoxic–oxic membrane reactor (A 2 O-MBR) system was developed to investigate the treatment ability of coal gasification wastewater. The removal capacity of each pollutants used in this system were determined at different hydraulic residence times (HRT) and mixed liquor recycle ratios (R). The experimental results showed that this system could effectively deal with COD and phenol removal and remain in a stable level when the operational parameters altered, while the nitrification was sensitive to operational conditions. The best performance was obtained at HRT of 48 h and R of 3. The maximum removal efficiencies of COD, NH 4 + -N and phenols were 97.4%, 92.8% and 99.7%, with final concentrations in the effluent of 71 mg/L, 9.6 mg/L and 3 mg/L, respectively. Organics degradation and transformation were analyzed by GC/MS and it was found that anaerobic process played an important role in degradation of refractory compounds.

  19. Design of passive decay heat removal system using thermosyphon for low temperature and low pressure pool type LWR

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jangsik; You, Byung Hyun; Jung, Yong Hun; Jeong, Yong Hoon [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2013-10-15

    In seawater desalination process which doesn't need high temperature steam, the reactor has profitability. KAIST has be developing the new reactor design, AHR400, for only desalination. For maximizing safety, the reactor requires passive decay heat removal system. In many nuclear reactors, DHR system is loop form. The DHR system can be designed simple by applying conventional thermosyphon, which is fully passive device, shows high heat transfer performance and simple structure. DHR system utilizes conventional thermosyphon and its heat transfer characteristics are analyzed for AHR400. For maximizing safety of the reactor, passive decay heat removal system are prepared. Thermosyphon is useful device for DHR system of low pressure and low temperature pool type reactor. Thermosyphon is operated fully passive and has simple structure. Bundle of thermosyphon get the goal to prohibit boiling in reactor and high pressure in reactor vessel.

  20. Coulometric sodium chloride removal system with Nafion membrane for seawater sample treatment.

    Science.gov (United States)

    Grygolowicz-Pawlak, Ewa; Sohail, Manzar; Pawlak, Marcin; Neel, Bastien; Shvarev, Alexey; de Marco, Roland; Bakker, Eric

    2012-07-17

    Seawater analysis is one of the most challenging in the field of environmental monitoring, mainly due to disparate concentration levels between the analyte and the salt matrix causing interferences in a variety of analytical techniques. We propose here a miniature electrochemical sample pretreatment system for a rapid removal of NaCl utilizing the coaxial arrangement of an electrode and a tubular Nafion membrane. Upon electrolysis, chloride is deposited at the Ag electrode as AgCl and the sodium counterions are transported across the membrane. This cell was found to work efficiently at potentials higher than 400 mV in both stationary and flow injection mode. Substantial residual currents observed during electrolysis were found to be a result of NaCl back diffusion from the outer side of the membrane due to insufficient permselectivity of the Nafion membrane. It was demonstrated that the residual current can be significantly reduced by adjusting the concentration of the outer solution. On the basis of ion chromatography results, it was found that the designed cell used in flow injection electrolysis mode reduced the NaCl concentration from 0.6 M to 3 mM. This attempt is very important in view of nutrient analysis in seawater where NaCl is a major interfering agent. We demonstrate that the pretreatment of artificial seawater samples does not reduce the content of nitrite or nitrate ions upon electrolysis. A simple diffusion/extraction steady state model is proposed for the optimization of the electrolysis cell characteristics.

  1. Awareness of dental surgeons in Pune and Mumbai, India, regarding chemomechanical caries removal system.

    Science.gov (United States)

    Bijle, Mohammed Nadeem Ahmed; Patil, Shankargouda; Mumkekar, Shahzad S; Arora, Nitin; Bhalla, Monika; Murali, K V

    2013-01-01

    To evaluate awareness of dental surgeons in Pune and Mumbai, India regarding chemomechanical caries removal system (CMCR). Sixty practicing dental surgeons from Mumbai (30) and Pune (30) were surveyed using questionnaire. Qualitative data was collected on the basis of structured schedule questionnaire method. Statistical analysis was done using SPSS v. 12.0. To test statistical significance, Chi-square test, Fishers exact test and Mann-Whitney U test were used. Of total respondents, 46.7% dental surgeons in Pune and 13.3% in Mumbai were aware about CMCR products. Carisolv® was known to 57.1% of dental surgeons in Pune and 75% in Mumbai, whereas, Papacarie® was known to 28.6% of dentists in Pune and none in Mumbai among the respondents aware about CMCR products. A significantly higher proportion of dental surgeons from Pune were aware about CMCR products compared to Mumbai. Dental surgeons from Mumbai were unaware about Papacarie®. Almost equal proportion of Dentists from Mumbai and Pune would like to undergo CDE programs to seek knowledge on CMCR, particularly Papacarie®.

  2. Double liquid membrane system for the removal of actinides and lanthanides from acidic nuclear wastes

    International Nuclear Information System (INIS)

    Chiarizia, R.; Danesi, P.R.

    1985-01-01

    Supported liquid membranes (SLM), consisting of an organic solution of n-octyl-(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) and tributyl-phosphate (TBP) in decalin are able to perform selective separation and concentration of actinide and lanthanide ions from aqueous nitrate feed solutions and synthetic nuclear wastes. In the membrane process a possible strip solution is a mixture of formic acid and hydroxylammonium formate (HAF). The effectiveness of this strip solution is reduced and eventually nullified by the simultaneous transfer through the SLM of nitric acid which accumulates in the strip solution. A possible way to overcome this drawback is to make use of a second SLM consisting of a primary amine which is able to extract only HNO 3 from the strip solution. In this work the results obtained by experimentally studying the membrane system: synthetic nuclear waste/CMPO-TBP membrane/HCOOH-HAF strip solution/primary amine membrane/NaOH solution, are reported. They show that the use of a second liquid membrane is effective in controlling the HNO 3 concentration in the strip solution, thus allowing the actinide and lanthanide ions removal from the feed solution to proceed to completion. 15 refs., 10 figs., 1 tab

  3. Adsorptive removal of congo red and sunset yellow dyes from water systems by lady finger stem

    International Nuclear Information System (INIS)

    Abbas, A.; Murtaza, S.; Ayub, R.; Rehman, R.; Zahid, A.

    2012-01-01

    Summary: In this research work two anionic dyes, i.e. Congo Red and Sunset Yellow were removed successfully from aqueous media by Lady Finger stem in batch mode. Operational conditions optimization showed that agitation speed and particle size did not affect much in adsorption of these dyes; but contact time, pH, adsorbent dose and temperature of system effects the adsorption rate. Optimized conditions of adsorption for Congo Red dye were: 40 minute contact time, 8.0 pH, 0.5 g adsorbent dose, 40-60 microns mesh sized particles, 150 rpm agitation speed and 50 degree C temperature. Whereas for Sunset Yellow optimized conditions were: 30 minute contact time, 2.0 pH, 2.5 g adsorbent dose, 20-40 microns mesh sized particles, 50 rpm agitation speed and 30 degree C temperature. Suitability of equilibrium data was modulated with Langmuir, Freundlich and Temkin models and found that both physisorption and chemisorption processes play important role in adsorption of these dyes by Lady Finger stem. The results demonstrated that Lady Finger stem can be efficiently employed on larger scale wastewater treatment. (author)

  4. Measurement and removal of cladding light in high power fiber systems

    Science.gov (United States)

    Walbaum, Till; Liem, Andreas; Schreiber, Thomas; Eberhardt, Ramona; Tünnermann, Andreas

    2018-02-01

    The amount of cladding light is important to ensure longevity of high power fiber components. However, it is usually measured either by adding a cladding light stripper (and thus permanently modifying the fiber) or by using a pinhole to only transmit the core light (ignoring that there may be cladding mode content in the core area). We present a novel noninvasive method to measure the cladding light content in double-clad fibers based on extrapolation from a cladding region of constant average intensity. The method can be extended to general multi-layer radially symmetric fibers, e.g. to evaluate light content in refractive index pedestal structures. To effectively remove cladding light in high power systems, cladding light strippers are used. We show that the stripping efficiency can be significantly improved by bending the fiber in such a device and present respective experimental data. Measurements were performed with respect to the numerical aperture as well, showing the dependency of the CLS efficiency on the NA of the cladding light and implying that efficiency data cannot reliably be given for a certain fiber in general without regard to the properties of the guided light.

  5. Liquid membrane system for the removal and concentration of transuranic elements

    International Nuclear Information System (INIS)

    Timmins, M.R.; Wysk, S.R.; Smolensky, L.A.; Jiang, D.; Lumetta, G.J.

    1996-01-01

    The goal of this program is to develop an efficient, reliable, and radiation-resistant modified liquid membrane system (MLMS) for the selective removal and concentration of transuranic elements (TRUs) and strontium-90 from dissolved Hanford sludge wastes. The efforts are divided into three categories: (1) demonstration and optimization of the MLMS for the TRUEX and SREX processes using simulant waste solution; (2) development of a radiation-resistant microporous divider and membrane module for testing with actual waste solutions; and (3) demonstration of the MLMS for the TRUEX and SREX processes using actual Hanford waste. Successful completion of these development efforts will yield a compact, versatile, and reliable MLMS for implementation with the TRUEX and SREX processes. The MLMS is simple, stable, more efficient, and easier to control and operate than conventional solvent-extraction processes, such as those employing centrifugal contactors. In addition, the MLMS process offers operational cost savings over the conventional technology, by exhibiting at least a 10% reduction in the consumption of extractant chemicals

  6. Nitrate removal from polluted water by using a vegetated floating system.

    Science.gov (United States)

    Bartucca, Maria Luce; Mimmo, Tanja; Cesco, Stefano; Del Buono, Daniele

    2016-01-15

    Nitrate (NO3(-)) water pollution is one of the most prevailing and relevant ecological issues. For instance, the wide presence of this pollutant in the environment is dramatically altering the quality of superficial and underground waters. Therefore, we set up a floating bed vegetated with a terrestrial herbaceous species (Italian ryegrass) with the aim to remediate hydroponic solutions polluted with NO3(-). The floating bed allowed the plants to grow and achieve an adequate development. Ryegrass was not affected by the treatments. On the contrary, plant biomass production and total nitrogen content (N-K) increased proportionally to the amount of NO3(-) applied. Regarding to the water cleaning experiments, the vegetated floating beds permitted to remove almost completely all the NO3(-) added from the hydroponic solutions with an initial concentration of 50, 100 and 150 mg L(-1). Furthermore, the calculation of the bioconcentration factor (BCF) indicated this species as successfully applicable for the remediation of solutions polluted by NO3(-). In conclusion, the results highlight that the combination of ryegrass and the floating bed system resulted to be effective in the remediation of aqueous solutions polluted by NO3(-). Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Removal of soft deposits from the distribution system improves the drinking water quality.

    Science.gov (United States)

    Lehtola, Markku J; Nissinen, Tarja K; Miettinen, Ilkka T; Martikainen, Pertti J; Vartiainen, Terttu

    2004-02-01

    Deterioration in drinking water quality in distribution networks represents a problem in drinking water distribution. These can be an increase in microbial numbers, an elevated concentration of iron or increased turbidity, all of which affect taste, odor and color in the drinking water. We studied if pipe cleaning would improve the drinking water quality in pipelines. Cleaning was arranged by flushing the pipes with compressed air and water. The numbers of bacteria and the concentrations of iron and turbidity in drinking water were highest at 9 p.m., when the water consumption was highest. Soft deposits inside the pipeline were occasionally released to bulk water, increasing the concentrations of iron, bacteria, microbially available organic carbon and phosphorus in drinking water. The cleaning of the pipeline decreased the diurnal variation in drinking water quality. With respect to iron, only short-term positive effects were obtained. However, removing of the nutrient-rich soft deposits did decrease the microbial growth in the distribution system during summer when there were favorable warm temperatures for microbial growth. No Norwalk-like viruses or coliform bacteria were detected in the soft deposits, in contrast to the high numbers of heterotrophic bacteria.

  8. The protected areas system in Brazil as a baseline condition for wetlands management and fish conservancy: the example of the Pantanal National Park

    Directory of Open Access Journals (Sweden)

    Carla N. M. Polaz

    2017-09-01

    Full Text Available ABSTRACT Considering the need for the Brazilian government to develop tools for environmental monitoring for biodiversity conservancy purposes in the national protected areas system, this paper focuses on determining reference site metrics (or baselines for adapting the Index of Biotic Integrity (IBI based on the fish assemblages in the Pantanal National Park (PNP. The habitats in the PNP were grouped into four categories: main rivers, corixos (channels connecting the floodplain, permanent bays, and temporary bays. Fish samplings were performed at 12 points during the dry season (Oct-Nov 2010 and 2011. 146 fish species were identified from the total 18,954 individuals collected with standardized fishing gear. There was no association between the structure of the fish assemblage and categories, suggesting a theory on homogeneity of habitats. The final IBIPNP consists of nine metrics, most of them were framed in excellent class, some in fair, and none in poor. There was no significant difference in IBIPNP scores between the two sampled years. This approach provides a direct application for wetland management purposes.

  9. Investigating the mechanism of clofibric acid removal in Fe{sup 0}/H{sub 2}O systems

    Energy Technology Data Exchange (ETDEWEB)

    Ghauch, Antoine, E-mail: ag23@aub.edu.lb [American University of Beirut, Faculty of Arts and Sciences, Department of Chemistry, P.O. Box 11-0236, Riad El Solh - 1107-2020, Beirut (Lebanon); Abou Assi, Hala; Tuqan, Almuthanna [American University of Beirut, Faculty of Arts and Sciences, Department of Chemistry, P.O. Box 11-0236, Riad El Solh - 1107-2020, Beirut (Lebanon)

    2010-04-15

    Since the introduction of iron wall technology, the inherent relationship between contaminant removal and iron corrosion has been mostly attributed to electron transfer from the metal body (direct reduction). This thermodynamically founded premise has failed to explain several experimental facts. Recently, a new concept considering adsorption and co-precipitation as fundamental contaminant removal mechanisms was introduced. This consistent concept has faced very skeptic views and necessarily needs experimental validation. The present work was the first independent attempt to validate the new concept using clofibric acid (CLO) as model compound. For this purpose, a powdered Fe{sup 0} material (Fe{sup 0}) was used in CLO removal experiments under various experimental conditions. Additional experiments were performed with plated Fe{sup 0} (mFe{sup 0}: Fe{sup 0}/Pd{sup 0}, Fe{sup 0}/Ni{sup 0}) to support the discussion of removal mechanism. Main investigated experimental variables included: abundance of O{sub 2}, abundance of iron corrosion products (ICPs) and shaking operations. Results corroborated the concept that quantitative contaminant removal in Fe{sup 0}/H{sub 2}O systems occurs within the oxide-film in the vicinity of Fe{sup 0}. Additionally, mixing type and shaking intensity significantly influenced the extent of CLO removal. More importantly, HPLC/MS revealed that the identity of reaction products depends on the extent of iron corrosion or the abundance of ICPs. The investigation of the CLO/Fe{sup 0}/H{sub 2}O system disproved the popular view that direct reduction mediates contaminant removal in the presence of Fe{sup 0}.

  10. TWRS technical baseline database manager definition document

    International Nuclear Information System (INIS)

    Acree, C.D.

    1997-01-01

    This document serves as a guide for using the TWRS Technical Baseline Database Management Systems Engineering (SE) support tool in performing SE activities for the Tank Waste Remediation System (TWRS). This document will provide a consistent interpretation of the relationships between the TWRS Technical Baseline Database Management software and the present TWRS SE practices. The Database Manager currently utilized is the RDD-1000 System manufactured by the Ascent Logic Corporation. In other documents, the term RDD-1000 may be used interchangeably with TWRS Technical Baseline Database Manager

  11. Comparison of hydraulics and particle removal efficiencies in a mixed cell raceway and Burrows pond rearing system

    Science.gov (United States)

    Moffitt, Christine M.

    2016-01-01

    We compared the hydrodynamics of replicate experimental mixed cell and replicate standard Burrows pond rearing systems at the Dworshak National Fish Hatchery, ID, in an effort to identify methods for improved solids rem