Sample records for remote afterloading brachytherapy

  1. Human error in remote Afterloading Brachytherapy

    International Nuclear Information System (INIS)

    Quinn, M.L.; Callan, J.; Schoenfeld, I.; Serig, D.

    1994-01-01

    Remote Afterloading Brachytherapy (RAB) is a medical process used in the treatment of cancer. RAB uses a computer-controlled device to remotely insert and remove radioactive sources close to a target (or tumor) in the body. Some RAB problems affecting the radiation dose to the patient have been reported and attributed to human error. To determine the root cause of human error in the RAB system, a human factors team visited 23 RAB treatment sites in the US. The team observed RAB treatment planning and delivery, interviewed RAB personnel, and performed walk-throughs, during which staff demonstrated the procedures and practices used in performing RAB tasks. Factors leading to human error in the RAB system were identified. The impact of those factors on the performance of RAB was then evaluated and prioritized in terms of safety significance. Finally, the project identified and evaluated alternative approaches for resolving the safety significant problems related to human error

  2. Radiation Exposure Reduction to Brachytherapy Staff By Using Remote Afterloading

    International Nuclear Information System (INIS)

    Attalla, E.M.

    2005-01-01

    The radiation exposures to the personnel staff from patients with brachytherapy implants in a brachytherapy service were reviewed. Exposures to the brachytherapy personnel, as determined by Thermoluminescence Dosimeter (TLD) monitors, indicates a four-fold reduction in exposures after the implantation of the use of remote afterloading devices. Quarterly TLD monitor data for seven quarters prior to the use of remote afterloading devices demonstrate an average projected annual dose equivalent to the brachytherapy staff of 2543 Μ Sv. After the implantation of the remote afterloading devices, the quarterly TLD monitor data indicate an average dose equivalent per person of 153 Μ Sv. This is 76% reduction in exposure to brachytherapy personnel with the use of these devices

  3. Afterloading techniques in brachytherapy

    International Nuclear Information System (INIS)

    Kirsch, M.; Orban, R.; Lorenz, B.

    1981-01-01

    The advantages of applying modern afterloading methods in brachytherapie of malignant diseases are outlined. They include, among other things, a considerable reduction in radiation exposure to staff involved. Furthermore, the radiation protection requirements imposed by the licensing authority on the construction, equipment and operation of remote controlled afterloading installations with gamma sources of up to 4 TBq (108 Ci) have been compiled. (author)

  4. Remote Afterloading High Dose Rate (HDR) Endobronchial Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Hyesook; Choi, Eun Kyung; Yi, Byong Yong; Kim, Won Dong; Kim, Woo Sung; Koh, Youn Suck [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    1991-12-15

    Authors described the remote afterloading endobronchial brachytherapy (EBBT) technique using the microSelectron HDR Ir-192 and the Asan Medical Center experience. Total 28 EBBT in 9 patients were performed since November 1989 and 24 EBBT in 8 patients were employed for palliation and 3 EBBT in 1 patient was treated curatively. Authors observed a significant relief of obstructive symptom with tumor regression in 7 patients out of 8 who were treated palliatively but one of them died of pulmonary congestion in 3 weeks after EBBT. One patient with prior therapy of extensive electrocautery expired within 1 day after 2nd EBBT procedure with massive hemorrhage from the lesion. EBBT procedure has been tolerable and can be performed as an outpatient.

  5. Remote Afterloading High Dose Rate (HDR) Endobronchial Brachytherapy

    International Nuclear Information System (INIS)

    Chang, Hyesook; Choi, Eun Kyung; Yi, Byong Yong; Kim, Won Dong; Kim, Woo Sung; Koh, Youn Suck

    1991-01-01

    Authors described the remote afterloading endobronchial brachytherapy (EBBT) technique using the microSelectron HDR Ir-192 and the Asan Medical Center experience. Total 28 EBBT in 9 patients were performed since November 1989 and 24 EBBT in 8 patients were employed for palliation and 3 EBBT in 1 patient was treated curatively. Authors observed a significant relief of obstructive symptom with tumor regression in 7 patients out of 8 who were treated palliatively but one of them died of pulmonary congestion in 3 weeks after EBBT. One patient with prior therapy of extensive electrocautery expired within 1 day after 2nd EBBT procedure with massive hemorrhage from the lesion. EBBT procedure has been tolerable and can be performed as an outpatient

  6. A compilation of current regulations, standards and guidelines in remote afterloading brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Tortorelli, J.P.; Simion, G.P.; Kozlowski, S.D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1994-10-01

    Over a dozen government and professional organizations in the United States and Europe have issued regulations and guidance concerning quality management in the practice of remote afterloading brachytherapy. Information from the publications of these organizations was collected and collated for this report. This report provides the brachytherapy licensee access to a broad field of quality management information in a single, topically organized document.

  7. A compilation of current regulations, standards and guidelines in remote afterloading brachytherapy

    International Nuclear Information System (INIS)

    Tortorelli, J.P.; Simion, G.P.; Kozlowski, S.D.

    1994-10-01

    Over a dozen government and professional organizations in the United States and Europe have issued regulations and guidance concerning quality management in the practice of remote afterloading brachytherapy. Information from the publications of these organizations was collected and collated for this report. This report provides the brachytherapy licensee access to a broad field of quality management information in a single, topically organized document

  8. Remote-controlled afterloading for intracavitary brachytherapy in gynecological carcinomas

    International Nuclear Information System (INIS)

    Rotte, K.

    1983-01-01

    Classical radiotherapy is gradually being replaced by remote-controlled afterloading procedures in the intracavitary treatment of tumors found during gynecological examination. These new procedures practically eliminate the exposure of the clinic staff to radiation. The possibilities of this new method are discussed with regard to the physics and biology of radiation. Our own results with this new method are reported. (orig.)

  9. Reduction in radiation exposure to nursing personnel with the use of remote afterloading brachytherapy devices

    International Nuclear Information System (INIS)

    Grigsby, P.W.; Perez, C.A.; Eichling, J.; Purdy, J.; Slessinger, E.

    1991-01-01

    The radiation exposure to nursing personnel from patients with brachytherapy implants on a large brachytherapy service were reviewed. Exposure to nurses, as determined by TLD monitors, indicates a 7-fold reduction in exposure after the implementation of the use of remote afterloading devices. Quarterly TLD monitor data for six quarters prior to the use of remote afterloading devices demonstrate an average projected annual dose equivalent to the nurses of 152 and 154 mrem (1.5 mSv). After the implementation of the remote afterloading devices, the quarterly TLD monitor data indicate an average dose equivalent per nurse of 23 and 19 mrem (0.2 mSv). This is an 87% reduction in exposure to nurses with the use of these devices (p less than 0.01)

  10. Human factors evaluation of remote afterloading brachytherapy: Human error and critical tasks in remote afterloading brachytherapy and approaches for improved system performance. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Callan, J.R.; Kelly, R.T.; Quinn, M.L. [Pacific Science and Engineering Group, San Diego, CA (United States)] [and others

    1995-05-01

    Remote Afterloading Brachytherapy (RAB) is a medical process used in the treatment of cancer. RAB uses a computer-controlled device to remotely insert and remove radioactive sources close to a target (or tumor) in the body. Some RAB problems affecting the radiation dose to the patient have been reported and attributed to human error. To determine the root cause of human error in the RAB system, a human factors team visited 23 RAB treatment sites in the US The team observed RAB treatment planning and delivery, interviewed RAB personnel, and performed walk-throughs, during which staff demonstrated the procedures and practices used in performing RAB tasks. Factors leading to human error in the RAB system were identified. The impact of those factors on the performance of RAB was then evaluated and prioritized in terms of safety significance. Finally, the project identified and evaluated alternative approaches for resolving the safety significant problems related to human error.

  11. Human factors evaluation of remote afterloading brachytherapy: Human error and critical tasks in remote afterloading brachytherapy and approaches for improved system performance. Volume 1

    International Nuclear Information System (INIS)

    Callan, J.R.; Kelly, R.T.; Quinn, M.L.

    1995-05-01

    Remote Afterloading Brachytherapy (RAB) is a medical process used in the treatment of cancer. RAB uses a computer-controlled device to remotely insert and remove radioactive sources close to a target (or tumor) in the body. Some RAB problems affecting the radiation dose to the patient have been reported and attributed to human error. To determine the root cause of human error in the RAB system, a human factors team visited 23 RAB treatment sites in the US The team observed RAB treatment planning and delivery, interviewed RAB personnel, and performed walk-throughs, during which staff demonstrated the procedures and practices used in performing RAB tasks. Factors leading to human error in the RAB system were identified. The impact of those factors on the performance of RAB was then evaluated and prioritized in terms of safety significance. Finally, the project identified and evaluated alternative approaches for resolving the safety significant problems related to human error

  12. Human factors evaluation of remote afterloading brachytherapy. Volume 2, Function and task analysis

    Energy Technology Data Exchange (ETDEWEB)

    Callan, J.R.; Gwynne, J.W. III; Kelly, T.T.; Muckler, F.A. [Pacific Science and Engineering Group, San Diego, CA (United States); Saunders, W.M.; Lepage, R.P.; Chin, E. [University of California San Diego Medical Center, CA (United States). Div. of Radiation Oncology; Schoenfeld, I.; Serig, D.I. [Nuclear Regulatory Commission, Washington, DC (United States). Div. of Systems Technology

    1995-05-01

    A human factors project on the use of nuclear by-product material to treat cancer using remotely operated afterloaders was undertaken by the Nuclear Regulatory Commission. The purpose of the project was to identify factors that contribute to human error in the system for remote afterloading brachytherapy (RAB). This report documents the findings from the first phase of the project, which involved an extensive function and task analysis of RAB. This analysis identified the functions and tasks in RAB, made preliminary estimates of the likelihood of human error in each task, and determined the skills needed to perform each RAB task. The findings of the function and task analysis served as the foundation for the remainder of the project, which evaluated four major aspects of the RAB system linked to human error: human-system interfaces; procedures and practices; training and qualifications of RAB staff; and organizational practices and policies. At its completion, the project identified and prioritized areas for recommended NRC and industry attention based on all of the evaluations and analyses.

  13. Human factors evaluation of remote afterloading brachytherapy. Volume 2, Function and task analysis

    International Nuclear Information System (INIS)

    Callan, J.R.; Gwynne, J.W. III; Kelly, T.T.; Muckler, F.A.; Saunders, W.M.; Lepage, R.P.; Chin, E.; Schoenfeld, I.; Serig, D.I.

    1995-05-01

    A human factors project on the use of nuclear by-product material to treat cancer using remotely operated afterloaders was undertaken by the Nuclear Regulatory Commission. The purpose of the project was to identify factors that contribute to human error in the system for remote afterloading brachytherapy (RAB). This report documents the findings from the first phase of the project, which involved an extensive function and task analysis of RAB. This analysis identified the functions and tasks in RAB, made preliminary estimates of the likelihood of human error in each task, and determined the skills needed to perform each RAB task. The findings of the function and task analysis served as the foundation for the remainder of the project, which evaluated four major aspects of the RAB system linked to human error: human-system interfaces; procedures and practices; training and qualifications of RAB staff; and organizational practices and policies. At its completion, the project identified and prioritized areas for recommended NRC and industry attention based on all of the evaluations and analyses

  14. Clinical result of high-dose rate intraluminal brachytherapy for esophageal carcinoma with a remote afterloading system

    International Nuclear Information System (INIS)

    Fukuda, Haruyuki; Nakajima, Toshifumi; Tada, Takuhito; Tanaka, Masahiro; Tsumura, Masashi; Onoyama, Yasuto

    1992-01-01

    During the period from 1977 through 1987, 105 patients with esophageal carcinoma were radically treated by radiotherapy. Forty-six patients receiving therapy before August 1982 were all treated by external beam therapy alone (Group 1). Since September 1982, 26 patients were treated by external beam therapy alone (Group 2) and 33 patients were treated by high-dose-rate intraluminal brachytherapy with a remote afterloading system combined with external beam therapy (Group 3). Dose of external beam therapy for Group 1, Group 2 and Group 3 patients were 66.7 Gy, 68.7 Gy and 55.9 Gy on the average. The intraluminal brachytherapy was performed with a total dose of 12 Gy consisting of 3 Gy twice a week. Ten of 72 patients (14%) treated by external beam therapy alone achieved complete response, whereas 14 of 33 patients (42%) treated by high-dose-rate intraluminal brachytherapy combined with external beam therapy had complete response. One-, and 3-year survival rates were 36% and 10% in the Group 1, 32% and 12% in the Group 2 and 56% and 36% in the Group 3. For Group 3, good survival rate was obtained in tumorous type and serrated type. Patients with tumor of less than 5 cm in Group 3 had good survival. The data suggest that the high-dose-rate intraluminal bracytherapy prescribed as a boost therapy following external beam therapy is an effective therapy modality for esophageal carcinoma which is of non-circumferential tumor or less than 5 cm. (author)

  15. Human factors evaluation of remote afterloading brachytherapy. Supporting analyses of human-system interfaces, procedures and practices, training and organizational practices and policies. Volume 3

    International Nuclear Information System (INIS)

    Callan, J.R.; Kelly, R.T.; Quinn, M.L.

    1995-07-01

    A human factors project on the use of nuclear by-product material to treat cancer using remotely operated afterloaders was undertaken by the Nuclear Regulatory Commission. The purpose of the project was to identify factors that contribute to human error in the system for remote afterloading brachytherapy (RAB). This report documents the findings from the second, third, fourth, and fifth phases of the project, which involved detailed analyses of four major aspects of the RAB system linked to human error: human-system interfaces; procedures and practices; training practices and policies; and organizational practices and policies, respectively. Findings based on these analyses provided factual and conceptual support for the final phase of this project, which identified factors leading to human error in RAB. The impact of those factors on RAB performance was then evaluated and prioritized in terms of safety significance, and alternative approaches for resolving safety significant problems were identified and evaluated

  16. Human factors evaluation of remote afterloading brachytherapy. Supporting analyses of human-system interfaces, procedures and practices, training and organizational practices and policies. Volume 3

    Energy Technology Data Exchange (ETDEWEB)

    Callan, J.R.; Kelly, R.T.; Quinn, M.L. [Pacific Science & Engineering Group, San Diego, CA (United States)] [and others

    1995-07-01

    A human factors project on the use of nuclear by-product material to treat cancer using remotely operated afterloaders was undertaken by the Nuclear Regulatory Commission. The purpose of the project was to identify factors that contribute to human error in the system for remote afterloading brachytherapy (RAB). This report documents the findings from the second, third, fourth, and fifth phases of the project, which involved detailed analyses of four major aspects of the RAB system linked to human error: human-system interfaces; procedures and practices; training practices and policies; and organizational practices and policies, respectively. Findings based on these analyses provided factual and conceptual support for the final phase of this project, which identified factors leading to human error in RAB. The impact of those factors on RAB performance was then evaluated and prioritized in terms of safety significance, and alternative approaches for resolving safety significant problems were identified and evaluated.

  17. An afterloading brachytherapy device utilizing thermoplastic material

    International Nuclear Information System (INIS)

    Kim, T.H.; Gerbi, J.B.; Deibel, F.C.; Khan, F.M.; Priest, J.R.

    1989-01-01

    An afterloading brachytherapy device for treatment of residual cancer in an enucleated orbit with two cesium-137 sources was designed using a thermoplastic material, Aquaplast. The device consists of a face-mask support held in place with elastic bands around the head and an acrylic afterloading applicator. The device is very easy to make, holds the sources firmly in place, allows full mobility of the patient, and gives excellent dose distribution to the target area. It was easily tolerated by a 7-year-old child during the 50 h of treatment. (author). 3 refs.; 4 figs

  18. Quality audits of the remote-controlled automatically-driven gamma ray afterloading equipment used in brachytherapy in the Czech Republic

    International Nuclear Information System (INIS)

    Zackova, H.; Horakova, I.

    2001-01-01

    To reach safety and precise application of ionisation radiation to patients Atomic act declares, in its Article no. 7, requirements for medical exposure. There are also given -among others -the demands to i nstall the quality assurance programmes (QA) for medical actions and functions . Since 1997, when the act has been adopted, a set of five Recommendations of State Office for Nuclear Safety (SONS ) for radiotherapy has been prepared to instruct users how to prepare quality control system (i.e. system of tests required by of the regulation no.184/1997 Sb. -acceptance, status and constancy tests) for main types of sources used in radiotherapy for treatment of the patients. Among them also the Recommendation on QA in brachytherapy has been issued by SONS in 1998. National Radiation Protection Institute (NRPI) has been performing the regular in situ quality audits in which the chosen parameters (which could seriously influence the dose to the patients -i.e. absorbed dose, main geometrical and radiation parameters etc ) are independently checked by the NRPI experts. System of Quality Audits on the sources used in teletherapy has been introduced in 1997 and at present time they are smoothly carried out according the SONS's demands. This work describes the process of installing of the Quality Audit system on brachytherapy. The work described here forms the only part of the activities, which have been carrying out by the department of dosimetry gamma and X-rays of NRPI to support supervisions of SONS in the field of radiation protection in radiotherapy .Quality audits in brachytherapy will extend the possibilities of NRPI. The Methods NRPI 43-01.30 prepared by NRPI could be used as documentation for all types of test which are at present time required by Czech legislation for the remote-controlled automatically-driven gamma-ray afterloading equipment used in brachytherapy. (authors)

  19. Experiences with alanine dosimetry in afterloading brachytherapy

    International Nuclear Information System (INIS)

    Eberhardt, H.-J.; Gohs, U.

    1996-01-01

    At the present, the most commonly used dosimetry for radiotherapy applications are ionisation chambers and thermoluminescent dosimeters (TLD). However, there are some undesirable characteristics of these dosimetry systems, such as large detection volume (ionisation chamber) as well as fading of the radiation induced signal with time and destructive readout (TLG). The present study is an investigation into the use of the alanine/ESR dosimetry in fractionated afterloading brachytherapy during the whole radiotherapy course. There are some qualities which make alanine dosimetry attractive. These are the linear energy response, low fading under standard conditions, and the nondestructive readout. Thus the alanine dosimetry makes possible cumulative dose measurements during the radiotherapy course and an archival storage. By ionizing radiation (gamma, e, n, p, charged particles) free radicals (unpaired electrons) are produced in the amino acid alanine. The continuous wave electron spin resonance (ESR) spectroscopy is used to determine the number of free radicals, which is proportional to the absorbed dose and the alanine content of the dosimeter. The ESR measurements were made at room temperature using a Bruker EPR analyzer EMS-104. The dosimeters used in the test are alanine pellets (23.72 mg weight, 4.9 mm diameter, 1 mm height) as well as flexible alanine film dosimeters (thickness about 500 μm). The dosimeters consist of a blend of L-alpha-alanine and a binder. The alanine content of the pellets and the film dosimeters is about 88 % and 50 % by weight, respectively. The dosimeters for the calculation of the dose-effect-relationship were irradiated at the Physical-Technical Bundesanstalt in Braunschweig by a standard 60Co source. The maximum deviation from the calculated linear function is about 0.12 Gy in the dose range up to 80 Gy. The goal of medical applications was the superficial dose measurement in afterloading brachytherapy during the radiotherapy course in

  20. Intraluminal brachytherapy in carcinoma of the oesophagus: comparison of afterloading techniques

    International Nuclear Information System (INIS)

    Udaya Kumar, M.; Supe, S.S.; Swamy, Kumara; Keshava, S.L.; Anantha, N.

    1993-01-01

    For improved local control or palliation of oesophageal cancers, intra-luminal brachytherapy (ILB) has emerged as an increasingly popular treatment modality of therapy in recent years. In combination with external radiotherapy, after-loaded ILB can increase local control rates and may prolong survival of these patients. In this paper two techniques of ILB viz., manual and low dose-rate remote after loading methods, using caesium-137 tubes and pellets respectively, are described in detail. On comparison of these two techniques it was found that both of them were similar with respect to their physical characteristic (dose rate, dose fall-off, maximum spinal cord dose, total reference air kerma, etc.). Clinically, the manual after-loaded ILB technique was found to be easier to use when compared with the low-dose rate remote after-loader. In addition, the number of patients with uterine cancers being high in a developing country, it was found that it was inappropriate to use the low dose remote after-loaders, designed for use in gynaecological cancers, for ILB of oesophageal cancers. Therefore, in the absence of high dose rate after-loaders, which can be utilized for intracavitary treatments of both uterine and oesophageal malignancies effectively, the manual after-loading ILB system as described in this paper could be a practical alternative. (author). 19 refs., 4 figs., 2 tabs

  1. A new afterloading applicator for primary brachytherapy of endometrial cancer

    International Nuclear Information System (INIS)

    Bauer, M.; Schulz-Wendtland, R.

    1993-01-01

    The authors describe and have used a new afterloading applicator in six patients for primary radiation therapy of endometrial cancer. The first introduction of the applicator was done under general anaesthesia. Dilating the cervical canal to Heger 9 made insertion easier. Prior to application it is advisable to probe the lumen of the uterine cavity with a tube or curette to estimate how far the applicator must be spread open. For brachytherapy it is advantageous to remove necrotic tumour portions. This requires experienced hands to avoid perforation of the uterus. The new afterloading applicator is easy to use, and permits direct contact between the six tubes and the tumour. In conjunction with careful planning with the help of MRI, it provides an optimal system for the treatment of endometrial cancer. (Author)

  2. Afterloading

    Energy Technology Data Exchange (ETDEWEB)

    Watson, E R [Glasgow Western Infirmary (UK)

    1981-12-01

    In view of the likely revision of the Code of Practice for radiation safety for radiotherapy departments, a review of existing safety precautions is undertaken. Most of the dose to radiographers comes from unsealed sources (e.g. /sup 131/I) and the use of small sealed sources in the form of intracavitory insertions, implants and moulds. Small sealed sources are dealt with in particular. Factors considered in minimising the dose to operational personnel are shielding, distance, time and manual or automatic afterloading of the radiation source. A detailed discussion is given on various commercial afterloading devices and operational experience of treating carcinoma of the cervix at Glasgow is reported. It is concluded that manual afterloading does not protect the staff at greatest risk (usually nurses) and that automatic afterloading machines appear to be the ideal solution.

  3. Afterloading

    Energy Technology Data Exchange (ETDEWEB)

    Watson, E R [Glasgow Western Infirmary (UK)

    1981-12-01

    The protection of personnel, particularly nurses, looking after patients being treated with small sealed radioactive sources in the form of intracavitary insertions is one of the main outstanding radiation protection problems. Automatic afterloading machines would seem to be an ideal solution as manual afterloading does not protect the staff at greatest risk. High and low dose rate machines each have their own followers. The use of the low dose rate Selectron unit at Glasgow in the treatment of 35 patients mostly with carcinoma of the cervix is discussed. The Selectron unit has presented certain problems but these are gradually being overcome. The patients have accepted the machine fairly well but it is too early to give a meaningful assessment of the results.

  4. Mechanism of remote controlled after-loading radiotherapy unit

    International Nuclear Information System (INIS)

    Morimoto, Masaki

    1980-01-01

    Employing a small amount of Radium-226 or Cesium-137 source was to be used hitherto for the treatment of carcinoma of the uterine cervix in used After-loading techniques. It involved, however, radiation risk to the staff and patient. The long treatment time are also a pain (strain) on the patient. In recent years, we have developed a remote control after-loading unit, which was named as RALSTRON, which was complete eliminated the disadvantage of conventional radium therapy. This unit also has disadvantage, however, that the design for the remote after-loader for intracavitary applicators present considerable difficulties, because many sources of different active lengths and loading patterns are required. A solution to this problem was carried out by using small point source, placed in Tandem applicator, of high activity and moving them back slowly during the treatment. Recently, this unit was installed many hospitals about 80 units in Japan, and are used. In this paper are given about a mechanism and safety deviced of this unit. (author)

  5. 10 CFR 35.647 - Additional technical requirements for mobile remote afterloader units.

    Science.gov (United States)

    2010-01-01

    ... on the remote afterloader unit, on the control console, and in the facility; (3) Viewing and intercom... 10 Energy 1 2010-01-01 2010-01-01 false Additional technical requirements for mobile remote... MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery...

  6. Safety handling manual for high dose rate remote afterloading system

    International Nuclear Information System (INIS)

    1999-01-01

    This manual is mainly for safety handling of 192 Ir-RALS (remote afterloading system) of high dose rate and followings were presented: Procedure and document format for the RALS therapy and for handling of its radiation source with the purpose of prevention of human errors and unexpected accidents, Procedure for preventing errors occurring in the treatment schedule and operation, and Procedure and format necessary for newly introducing the system into a facility. Consistency was intended in the description with the quality assurance guideline for therapy with small sealed radiation sources made by JASTRO (Japan Society for Therapeutic Radiology and Oncology). Use of the old type 60 Co-RALS was pointed out to be a serious problem remained and its safety handling procedure was also presented. (K.H.)

  7. Radiological safety problems in intracavitary brachytherapy using the manual afterloading in Venezuela

    International Nuclear Information System (INIS)

    Lea, D.; Gonzales, E.; Gallardo, J.; Diaz, M.

    1996-01-01

    In three venezuelan public hospitals it was detected radioactive contamination for Cs-137 during inspection with the wipe test technique in areas where is applied intracavitary brachytherapy using manual afterloading. This caused a condition of great stress in the personal engaged the treatments. In each Cs-137 source in these hospitals was tested leakage. The source plastic holder was analysed. The authors were able to demonstrate: a) The radioactive contamination found in the treatment area had its origin in the Cs-137 capsule corrosion and b) The corrosion in the source capsule was produced by the radiolytic degradation of the PVC tube used as source-holder in the intracavitary treatments. (authors). 3 refs., 1 tab

  8. Postoperative vaginal cuff irradiation using high dose rate remote afterloading: a Phase II clinical protocol

    International Nuclear Information System (INIS)

    Noyes, William R.; Bastin, Kenneth; Edwards, Scott A.; Buchler, Dolores A.; Stitt, Judith A.; Thomadsen, Bruce R.; Fowler, Jack F.; Kinsella, Timothy J.

    1995-01-01

    Purpose: In September 1989, a postoperative Phase II high dose rate (HDR) brachytherapy protocol was started for International Federation of Gynecology and Obstetrics (FIGO) Stage I endometrial adenocarcinoma. This review reports the overall survival, local control, and complication rates for the initial 63 patients treated in this Phase II study. Methods and Materials: High dose rate brachytherapy was delivered using an Iridium-192 HDR remote afterloader. Sixty-three patients were entered into the Phase II protocol, each receiving two vaginal cuff treatments 1 week apart (range 4-12 days) with vaginal ovoids (diameter 2.0-3.0 cm). No patient received adjuvant external beam radiation. A dose of 32.4 Gy in two fractions was prescribed to the ovoid surface in 63 patients. The first three patients treated at our institution received 15, 16.2, and 29 Gy, respectively, to determine acute effects. Results: At a median follow-up of 1.6 years (range 0.75-4.3 years) no patient has developed a vaginal cuff recurrence. One regional recurrence (1.6%) occurred at 1.2 years at the pelvic side wall. This patient is alive and without evidence of disease 7 months after completion of salvage irradiation, which resulted in the only vaginal stenosis (1.6%). Fourteen patients (22%) experienced vaginal apex fibrosis by physical exam, which was clinically symptomatic in four patients. Two patients reported stress incontinence; however, these symptoms were noted prior to their HDR therapy. One patient died 2.4 years after HDR therapy due to cardiovascular disease without evidence of cancer at autopsy. Conclusion: Preliminary results of our phase II HDR vaginal cuff protocol for postoperative FIGO Stage IA, Grade 3 or Stage IB, Grade 1-2 patients demonstrate that 32.4 Gy in two fractions is well tolerated by the vaginal cuff mucosa. Local control appears comparable to our prior experience and others with low dose rate (LDR) brachytherapy. Additional patient accrual and further follow

  9. Tolerance of human skin applying pulsed brachytherapy with large afterloading moulds

    International Nuclear Information System (INIS)

    Fritz, Peter; Hensley, Frank W.; Berns, Christiane; Schraube, Peter; Wannenmacher, Michael

    1995-01-01

    Purpose: The concept of pulsed brachytherapy suggested by Brenner and Hall requires an unusual fractionation scheme. The effectiveness and sequelae of this new irradiation method was observed on patients with disseminated cutaneous metastases of breast cancer. Materials and Methods: A flexible, re-usable skin mould (weight 110 g) was developed for use with a PDR afterload. An array of 18 parallel catheters (2 mm diameter) at equal distances of 10 mm was constructed by fixation of the catheters in a plastic wire mesh. The array is sewn between two foam rubber slabs of 5 mm thickness to provide a defined constant distance to the skin. Irradiations are performed up to a maximum field size of 17 x 23,5 cm 2 with a nominal 37 GBq Ir-192 source in pulses of 1 Gy per hour at the skin surface. The dose distribution is geometrically optimized to provide a homogeneous skin dose (100±10%). The 80% dose level lies at 5 mm below the skin surface. 20 patients suffering from cutaneous metastases at the thoracic wall were treated with 22 fields (area irradiated: 100-919 cm 2 ) at total doses of 40 to 50 Gy applying two PDR courses with a pause of 4 to 6 weeks. 12 of the fields were previously irradiated with external beam therapy to doses of 40 to 60 Gy at 7 to 22 months in advance. Results: Complete remissions (CR) were achieved in 21 out of 22 fields. (18(20)) patients were free of relapse at the time of death or evaluation. Pre-irradiated fields (n=12): follow-up times 6-21,5 months (median: 11,5 months). CR: (11(12)) fields. Recurrencies:(2(12)) fields. Maximum degree of early skin reactions: marked erythema: (8(12)) fields; epitheliolysis (>50% field size): (4(12)) fields. Intermediate skin reactions after minimum follow-up of 6 months: pigmentation/atrophy: (8(12)) fields; marked teleangiectasia: (3(12)) fields; small skin necrosis:(1(12)) fields. Newly irradiated fields (n=11): follow-up: 6-13,5 months (median:8 month). CR: (11(11)) fields. Recurrencies:(0(11)) fields

  10. A new applicator system for afterloading brachytherapy of the uterine cervix

    International Nuclear Information System (INIS)

    Duehmke, E.; Busch, M. II; Kirschner, H.

    1990-01-01

    We developed a new application system for the intracavitary afterloading therapy of the cervix carcinoma. With this system special problems of the application as the possible perforation of the cervix uteri are prevented. (orig.) [de

  11. Citron - the first indigenous remote afterloading intracavitary brachytherapy unit

    International Nuclear Information System (INIS)

    Bhaskar, B.K.; Balakrishnan, I.S.; Vivekanandan, N.; Lakshmanan, A.V.

    2000-01-01

    In keeping with its tradition of pioneering cancer patient cure and care, the Cancer Institute embarked on a project funded by DAE in 1994 to develop an economical import substitute. The prototype unit named CITRON promises to be a suitable import substitute satisfying a long standing need in the country

  12. Clinical results in carcinoma of the cervix: radium compared to caesium using remote afterloading

    International Nuclear Information System (INIS)

    Jackson, S.M.; Fairey, R.N.; Kornelsen, R.O.; Young, M.E.J.; Wong, F.L.

    1989-01-01

    In 1979 the Cancer Control Agency of British Columbia changed from radium to remote controlled afterloaded caesium in the treatment of carcinoma of the cervix. In 3 years prior to the change, 139 patients received radium as part of their treatment and in the 3 years after the change, 158 patients received caesium. Overall referral patterns, patient and cancer demographics, and treatment policies were stable throughout the 6-year period. Radiotherapy technique, dose, dose distribution and dose rate were comparable for both radium and caesium treated patients. The results of treatment in the two time periods showed no difference in survival, local tumour control or complications. The use of afterloading has not compromised treatment results and has allowed better nursing care for patients and protection from radiation for all staff. (author)

  13. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  14. Physical optimization of afterloading techniques

    International Nuclear Information System (INIS)

    Anderson, L.L.

    1985-01-01

    Physical optimization in brachytherapy refers to the process of determining the radioactive-source configuration which yields a desired dose distribution. In manually afterloaded intracavitary therapy for cervix cancer, discrete source strengths are selected iteratively to minimize the sum of squares of differences between trial and target doses. For remote afterloading with a stepping-source device, optimized (continuously variable) dwell times are obtained, either iteratively or analytically, to give least squares approximations to dose at an arbitrary number of points; in vaginal irradiation for endometrial cancer, the objective has included dose uniformity at applicator surface points in addition to a tapered contour of target dose at depth. For template-guided interstitial implants, seed placement at rectangular-grid mesh points may be least squares optimized within target volumes defined by computerized tomography; effective optimization is possible only for (uniform) seed strength high enough that the desired average peripheral dose is achieved with a significant fraction of empty seed locations. (orig.) [de

  15. Inverse planning in brachytherapy from radium to high rate 192 iridium afterloading

    International Nuclear Information System (INIS)

    Lahanas, M.; Mould, R.F.; Baltas, D.; Karauzakis, K.; Giannouli, S.; Baltas, D.

    2004-01-01

    We consider the inverse planning problem in brachytherapy, i.e. the problem to determine an optimal number of catheters, number of sources for low-dose rate brachytherapy (LDR) and the optimal dwell times for high-dose rate brachytherapy (HDR) necessary to obtain an optimal as possible dose distribution. Starting from the 1930s, inverse planning for LDR brachytherapy used geometrically derived rules to determine the optimal placement of sources in order to achieve a uniform dose distribution of a specific level in planes, spheres and cylinders. Rules and nomograms were derived which still are widely used. With the rapid development of 3D imaging technologies and the rapidly increasing computer power we have now entered the new era of computer-based inverse planning in brachytherapy. The inverse planning is now an optimisation process adapted to the individual geometry of the patient. New inverse planning optimisation algorithms are anatomy-based that consider the real anatomy of the tumour and the organs at risk (OAR). Computer-based inverse planning considers various effects such as stability of solutions for seed misplacements which cannot ever be solved analytically without gross simplifications. In the last few years multiobjective (MO) inverse planning algorithms have been developed which recognise the MO optimisation problem which is inherent in inverse planning in brachytherapy. Previous methods used a trial and error method to obtain a satisfactory solution. MO optimisation replaces this trial and error process by presenting a representative set of dose distributions that can be obtained. With MO optimisation it is possible to obtain information that can be used to obtain the optimum number of catheters, their position and the optimum distribution of dwell times for HDR brachytherapy. For LDR brachytherapy also the stability of solutions due to seed migration can also be improved. A spectrum of alternative solutions is available and the treatment planner

  16. Fast neutron therapy with high intensity Cf-252 sources by remotely controlled afterloading and clinical experiences in the treatment of gynaecological cancers

    International Nuclear Information System (INIS)

    Yamashita, H.; Hashimoto, S.; Wada, M.; Dokiya, T.

    1986-01-01

    Cf-252 fast neutron therapy with high intensity Cf-252 sources was tested for the treatment of advanced gynaecological cancers using a remotely controlled afterloading machine designed by the author and manufactured by Toshiba. Using high intensity sources and short treatment times in a special treatment room, personnel or environment exposure to radiation was at a safe level, i.e. almost nil. During 1978-1983 18 stage III cases of cancer of the uterine cervix were treated with complete response in 78% and 44% 5 year survivals. The types of acute and delayed effects of Cf-252 were the same as Co-60 or Cs-137 but the rectum was found sensitive in this system of brachytherapy. A dose of 1,000-1,500 cGy/6-10 F in 10-22 days of Cf-252 radiation was tolerated and produced tumor cure

  17. Comparison of 60Cobalt and 192Iridium sources in high dose rate afterloading brachytherapy

    International Nuclear Information System (INIS)

    Richter, J.; Baier, K.; Flentje, M.

    2008-01-01

    Purpose: 60 Co sources with dimensions identical to those of 192 Ir have recently been made available in clinical brachytherapy. A longer half time reduces demands on logistics and quality assurance and perhaps costs. Material and Methods: Comparison of the physical properties of 60 Co and 192 Ir with regard to brachytherapy. Results: Required activities for the same air kerma rate are lower by a factor of 2.8 for 60 Co. Differential absorption in tissues of different densities can be neglected. Monte Carlo calculations demonstrate that integral dose due to radial dose fall off is higher for 192 Ir in comparison to 60 Co within the first 22 cm from the source (normalization at 1 cm). At larger distances this relationship is reversed. Conclusion: Clinical examples for intracavitary and interstitial applications however, show practically identical dose distributions in the treatment volume. (orig.)

  18. Monte Carlo Simulation of stepping source in afterloading intracavitary brachytherapy for GZP6 unit

    International Nuclear Information System (INIS)

    Toossi, M.T.B.; Abdollahi, M.; Ghorbani, M.

    2010-01-01

    Full text: Stepping source in brachytherapy systems is used to treat a target lesion longer than the effective treatment length of the source. Dose calculation accuracy plays a vital role in the outcome of brachytherapy treatment. In this study, the stepping source (channel 6) of GZP6 brachytherapy unit was simulated by Monte Carlo simulation and matrix shift method. The stepping source of GZP6 was simulated by Monte Carlo MCNPX code. The Mesh tally (type I) was employed for absorbed dose calculation in a cylindrical water phantom. 5 x 108 photon histories were scored and a 0.2% statistical uncertainty was obtained by Monte Carlo calculations. Dose distributions were obtained by our matrix shift method for esophageal cancer tumor lengths of 8 and 10 cm. Isodose curves produced by simulation and TPS were superimposed to estimate the differences. Results Comparison of Monte Carlo and TPS dose distributions show that in longitudinal direction (source movement direction) Monte Carlo and TPS dose distributions are comparable. [n transverse direction, the dose differences of 7 and 5% were observed for esophageal tumor lengths of 8 and 10 cm respectively. Conclusions Although, the results show that the maximum difference between Monte Carlo and TPS calculations is about 7%, but considering that the certified activity is given with ± I 0%, uncertainty, then an error of the order of 20% for Monte Carlo calculation would be reasonable. It can be suggested that accuracy of the dose distribution produced by TPS is acceptable for clinical applications. (author)

  19. High dose rate afterloading intraluminal brachytherapy for advanced inoperable rectal carcinoma

    International Nuclear Information System (INIS)

    Hoskin, Peter J.; Canha, Sandra M. de; Bownes, Peter; Bryant, Linda; Jones, Rob Glynne

    2004-01-01

    Background and purpose: High dose rate intraluminal brachytherapy for tumours of the rectal and anal canal which were inoperable either because of the age and frailty of the patient or because of advanced disease has been evaluated. Patients and methods: In a retrospective review of 50 consecutive patients the two main indications for brachytherapy were as part of a radical radiation programme in those unfit for major surgery (26 patients) or as palliation for advanced or metastatic disease (22 patients). Radical treatment was either sole treatment delivering 6 Gy fraction 2 to 3 times weekly up to 36 Gy or as a boost of 12 Gy after 45 Gy in 25 fractions external beam chemoradiation. Palliative treatments were given predominantly as a single dose of 10 Gy. Results: This was predominantly a group of frail elderly patients with a median age of 82 years (range 35-91). Local tumour response was seen in 21/25 assessable patients with 14 complete responses. Median survival for the entire population was 6 months (range 1-54 months); in patients treated with 'radical' intent this was 25 months (range 1.5-54) and in the palliative group 7.2 months (range 1-37). The most common presenting symptom was bleeding per rectum for which a 64% response rate was obtained with 57% complete responses. Mucous discharge responded in 64% with 28% complete responses. The median duration of response was 7 months. Conclusion: Intraluminal HDR brachytherapy is an effective local treatment for patients otherwise unfit for radical surgery both as a component of radical treatment, or as a simple single palliative procedure

  20. Implementation of 'early alert system' area detector at patient from entrance in afterloading brachytherapy

    International Nuclear Information System (INIS)

    Videla Valdebenito, R.

    2001-01-01

    A system of area monitors to detect the involuntary exit of the radiation sources used in low dose rate deferred brachytherapy treatment is being implemented in all facilities in Chile. The first implementation of this system, named 'Early Alert', was 5 years ago as a complement to the administrative procedures and verification measures by the medical physics carried out through visual verifications and by means of portable radiation detectors. This detector of the system should be located preferentially at the exit of the treatment room at a height not smaller than two meters. This has resulted in an increase of facilities safety in this practice. (author) [es

  1. High-dose-rate afterloading brachytherapy in carcinoma of the cervix: an experience of 1992 patients

    International Nuclear Information System (INIS)

    Lorvidhaya, Vicharn; Tonusin, Anun; Changwiwit, Witit; Chitapanarux, Imjai; Srisomboon, Jatupol; Wanwilairat, Somsak; Chawapun, Nisa; Sukthomya, Vimol

    2000-01-01

    Purpose: To report the results of radiation therapy in carcinoma of the cervix treated by external irradiation and high-dose-rate (HDR) intracavitary brachytherapy. Methods and Materials: This is a retrospective analysis of 2063 patients with histologically proven carcinoma of the cervix treated by external irradiation and HDR intracavitary brachytherapy between March 1985-December 1991. The Kaplan-Meier method was used for survival and disease-free survival analysis. Late complications in the bowel and bladder were calculated actuarially. Results: There were 71 patients who did not complete the course of irradiation so only 1992 patients were retrospectively analyzed for survival. There were 2 patients (0.1%) in Stage IA, 211 (10.2%) Stage IB, 225 (10.9%) in Stage IIA, 902 (43.7%) in Stage IIB, 14 (0.7%) in Stage IIIA, 675 (32.7%) in Stage IIIB, 16 (0.8%) in Stage IVA, and 16 (0.8%) in Stage IVB. The median follow-up time was 96 months. The actuarial 5-year disease-free survival rate was 79.5%, 70.0%, 59.4%, 46.1%, 32.3%, 7.8%, and 23.1% for Stage IB, IIA, IIB, IIIA, IIIB, IVA, and IVB respectively. The actuarial 5-year disease-free survival rate for Stage IB 1 and IB 2 squamous cell carcinoma was 88.7% and 67.0%. The actuarial 5-year overall survival rate was 86.3%, 81.1%, 73.0%, 50.3%, 47.8%, 7.8%, and 30.8% for Stage IB, IIA, IIB, IIIA, IIIB, IVA, and IVB respectively. Pattern of failure revealed 20.8% local recurrence, 18.7% distant metastases, and 4% in both. The late complication rate Grade 3 and 4 (RTOG) for bowel and bladder combined was 7.0% with 1.9% Grade 4. Conclusion: HDR brachytherapy used in this series produced pelvic control and survival rates comparable to other LDR series

  2. High-dose rate brachytherapy in the treatment of carcinoma of uterine cervix: twenty-year experience with cobalt after-loading system.

    Science.gov (United States)

    Mosalaei, A; Mohammadianpanah, M; Omidvari, S; Ahmadloo, N

    2006-01-01

    This retrospective analysis aims to report results of patients with cancer of uterine cervix treated with external-beam radiotherapy (EBR) and high-dose rate (HDR) brachytherapy, using manual treatment planning. From 1975 to 1995, 237 patients with FIGO stages IIB-IVA and mean age of 54.31 years were treated. EBR dose to the whole pelvis was 50 Gy in 25 fractions. Brachytherapy with HDR after-loading cobalt source (Cathetron) was performed following EBR completion with a dose of 30 Gy in three weekly fractions of 10 Gy to point A. Survival, local control, and genitourinary and gastrointestinal complications were assessed. In a median follow-up of 60.2 months, the 10-year overall and disease-free survival rate was 62.4%. Local recurrence was seen in 12.2% of patients. Distant metastases to the lymph nodes, peritoneum, lung, liver, and bone occurred in 25.3% of patients. Less than 6% of patients experienced severe genitourinary and/or gastrointestinal toxicity that were relieved by surgical intervention. No treatment-related mortality was seen. This series suggests that 50 Gy to the whole pelvis together with three fractions of 10 Gy to point A with HDR brachytherapy is an effective fractionation schedule in the treatment of locally advanced cancer of cervix. To decrease the complications, newer devices and treatment planning may be beneficial.

  3. Pre-installation empirical testing of room shielding for high dose rate remote afterloaders

    International Nuclear Information System (INIS)

    Klein, E.E.; Grigsby, P.W.; Williamson, J.F.; Meigooni, A.S.

    1993-01-01

    PURPOSE: Many facilities are acquiring high dose rate remote afterloading units. It is economical that these units be placed in existing shielded teletherapy rooms. Scatter-radiation barriers marginally protect uncontrolled areas from a high dose rate source especially in a room that houses a non-dynamic Cobalt-60 unit. In addition the exact thickness and material composition of the barriers are unknown and therefore, a calculation technique may give misleading results. Also, it would be impossible to evaluate an entire wall barrier by taking isolated core samples in order to assist in the calculations. A quick and inexpensive measurement of dose equivalent using a rented high activity 192Ir source evaluates the barriers and locates shielding deficiencies. METHODS AND MATERIALS: We performed transmission calculations for primary and scattered radiation based on National Council on Radiation Protection and Measurements Reports 49 and 51, respectively. We then rented a high activity 21.7 Ci (8.03 x 10(11) Bq) Ir-192 source to assess our existing teletherapy room shielding for adequacy and voids. This source was placed at the proposed location for clinical high dose rate treatment and measurements were performed. RESULTS: No deficiencies were found in controlled areas surrounding the room, but large differences were found between the calculated and measured values. Our survey located a region in the uncontrolled area above the room requiring augmented shielding which was not predicted by the calculations. A canopy shield was designed to potentially augment the shielding in the ceiling direction. CONCLUSION: Pre-installation testing by measurement is an invaluable method for locating shielding deficiencies and avoiding unnecessary enhancement of shielding particularly when there is lack of information of the inherent shielding

  4. Radiation treatment of esophageal carcinoma using a high-dose-rate remote afterloader

    International Nuclear Information System (INIS)

    Hishikawa, Yoshio

    1984-01-01

    Between May 1980 and March 1983, 31 patients with esophageal carcinoma were treated with a high-dose-rate remote controlled afterloading unit, as a boost therapy of the intracavitary irradiation following the external irradiation. The data of these patients were analyzed by the regression analysis which is one of the multivariate analyses, and following results were obtained. 1) Factors which affect local control achieved by intracavitary irradiation were the existence of deep ulcer or stenosis after external irradiation, age of the patient, dosage of intracavitary irradiation and tumor length. 2) The local control estimation index was determined by these five factors. Local control estimation index=1.38950-0.01571 x age+0.04517 x tumor length+0.62167 x stenosis* + 0.94811 x deep ulcer*-0.02969 x dosage of intracavitary irradiation. * Existence of stenosis/ulcer was represented by 1, and absence was represented by 0. 3) The local control estimation indices obtained in the above formula were then approved by applying internal samples, and also external samples. Indices of 0.5 or more mean local failure, and those of less than 0.5 mean possible local control. Examination was then made as to the local control estimation indices of another group of 30 patients who had been treated by external irradiation alone between November 1974 and April 1980. Comparison of the indices of the two groups showed the following results. 1) Rate of possible local control by external irradiation alone was 23%. 2) Rate of possible local control was increased up to 62% by using intracavitary irradiation following external irradiation. (author)

  5. Installations for radiation therapy with remote controlled afterloading technique. Ferngesteuerte Applikationsanlagen zur Therapie mit umschlossenen radioaktiven Stoffen

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    Installations for radiation therapy with remote controlled afterloading technique; radiation protection rules for fabrication and construction; amendment 1 to draft standard (DIN) 6853. Compared to the draft standard of Semptember 1980, the following modifications are planned as amendment 1: a. Paragraph no. 1: In the title, the word ''scope'' is changed into ''field of application''. The words ''by moving the radiation source electromecanically'' are deleted. b. Paragraph no. 2'' Standards also applicable'' and the list of ''Additional standards'' are summarized under the heading ''Standards and supporting documents'' (without any paragraph number). c. Paragraph no. 3 ''Terms'' is completed by additional terms and their definitions.

  6. Esthesioneuroblastoma - treatment of recurrences by means of remote-controlled afterloading-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Bauer, M.; Wilhelm, K.R.; Mende, U.; Dreyer, M.

    1990-01-01

    At the Radiological Hospital of the Heidelberg University, one patient with a local recurrence of an esthesioneuroblastoma situated on the left-hand side of the skull base was treated between February 11 and March 18, 1986, by an afterloading contact therapy with curative intent. After preceding surgery and percutaneous radiotherapy, repeated local recurrences and locoregional lymph node metastases had occured. The contact therapy was performed after adjusting an individual face mask in which the afterloading probe was placed and brought into its position in the tumor region. The irradiation scheme was based on the transformation of the source coordinates from the stereoscopic X-ray localization system into the coordinate system of the computed tomogram by means of X-ray right reference points. The irradiation planning by computed tomography allows to optimize the arrangement of sources within the tumor region. The principles of the method as well as the treatment result are presented. (orig.) [de

  7. Volume and dose rate dependent (MDR-LDR Ir-192 afterloading interstitial brachytherapy) treatment optimisation, for squamouscell carcinoma of the lip

    International Nuclear Information System (INIS)

    Stas, Nathalie; Goncalves, Julieta; Pinho, Eliana; Trigo, Lurdes; Fernandes, Tome; Vieira, Elio

    1996-01-01

    Introduction: From 1/1/90 to 1/1/95, 53 patients with squamouscell carcinoma of the lip were treated by MDR or LDR Ir-192 afterloading interstitital brachytherapy. We compare the oncological and aesthetical results and sequelae depending on the volume and the dose rate. Material and methods: 53 patients, 41 men and 12 women, median age = 66y; 48 primary tumors (T1 = 26; T2 = 16; T3 = 6; N0 = 47; N1 = 1; M0 = 48) and 5 recurrencies; squamouscell carcinoma (grade 1 =45, g2 =6, g3 =2); clinical extension: buccal comissure=3, check =2, muscular =15, skin =7, lower and upper lip =1. Before radiotherapy, 28 biopsies and 25 excisional surgeries (19 with positive margins, 6 with negative margins) were performed. Brachytherapy was performed alone (dose 60-75 Gy BD85%) or as a boost (dose 10-30 Gy BD85%) associated with external beam (dose 46-50 Gy). MDR or LDR microselectron's afterloading was done after a computerised dosimetry (Paris System): treatment mean time = 30, 98 hours; mean volume = 10,2 cc (T1-T2 8, 61cc); Ir - 192 activity = range 0,7 - 4,792 mCi/cm; reference dose rate 45,6 - 290, 1 cGy/h. Results: 46 patients are alive without cancer, 1 died without responding, 6 died from non oncological diseases; 8 patients had recurrences (5 local, 3 nodal) but are alive. Mean follow-up 30,83 months (range 3-60m), mean DFS = 22,49 m (range 5-57m). Acute secondary effects: 30 radioepithelyties (grade 1 = 7, g2=23, g3=14), and 39 radiomucitis (g1=3; g2=23; g3=13); mean time for complete healing = 21, 66 days. Sequelae: moderate sclerosis of the skin =11, skin retraction = 1, hyperpigmentation2, depigmentation= 10, edema= 6, gingivitis= 7. Aesthetical results: good32; moderate= 18; bad= 2, very bad= 1 (uncontrolled tumor). Conclusions: The sequelae and aesthetical results are closely dependent on the treated volume and the dose rate, less dependent on the total dose, and independent on the Iridium activity. Complete healing time does not influence the late aesthetical results

  8. Brachytherapy source calibration, reviews, and consistency of 192Ir high-dose rate afterloading sources supplied over the period of 10 years: a retrospective analysis

    International Nuclear Information System (INIS)

    Nagappan, Balasubramanian; Kumar, Yogesh; Patel, Narayan P.; Dhull, Anil Kumar; Kaushal, Vivek

    2015-01-01

    Measurement and verification of strength of monomodal high-dose rate (mHDR) 192 Ir source supplied by the vendor is a major part of quality assurance program. Reference air kerma rate (RAKR) or air kerma strength (AKS) is the recommended quantity to specify the strength of gamma emitting brachytherapy sources. Physicist in our institution performed the source calibration as soon as each 192 Ir new source was loaded on the mHDR afterloading machine. The AKS accurately measured using a physikalisch technische werkstatten (PTW) re-entrant chamber-electrometer system in a scatter-free geometry was used to compute the air kerma rate (AKR) at one-meter distance in the air. To ensure accurate dose delivery to brachytherapy patients, measured AKS or RAKR should be entered correctly in both HDR treatment console station (TCS) as well as treatment planning system (TPS) associated with it. The clinical outcome mainly depends not only on the accuracy of the source strength measurement in the hospital but also on the correct source strength entered into both TCS and TPS software. A retrospective study on 22 mHDR V2 sources supplied by the vendor for the period of 10 years was taken up to access the accuracy of source strength supplied to the Radiotherapy department. The results are analyzed and reported. The accuracy in measured RAKR of all 22 sources supplied by vendor was well within the tolerance limits set by the national regulatory body and international recommendations. The deviations observed between measured RAKR versus manufacturer's quoted RAKR were in the range from -1.71% to +1.15%. In conclusion, the measured RAKR have good agreement with vendor quoted RAKR values. (author)

  9. Procedures for calibration of brachytherapy sources

    International Nuclear Information System (INIS)

    Alfonso Laguardia, R.; Alonso Samper, J.L.; Morales Lopez, J.L.; Saez Nunez, D.G.

    1997-01-01

    Brachytherapy source strength verification is a responsibility of the user of these source, in fact of the Medical Physicists in charge of this issue in a Radiotherapy Service. The calibration procedures in the users conditions are shown. Specifics methods for source strength determination are recommended, both for High Dose Rate (HDR) sources with Remote Afterloading equipment and for Low Dose Rate sources. The The results of the calibration of HDR Remote After loaders are indicated

  10. Identifying afterloading PDR and HDR brachytherapy errors using real-time fiber-coupled Al2O3:C dosimetry and a novel statistical error decision criterion

    International Nuclear Information System (INIS)

    Kertzscher, Gustavo; Andersen, Claus E.; Siebert, Frank-Andre; Nielsen, Soren Kynde; Lindegaard, Jacob C.; Tanderup, Kari

    2011-01-01

    Background and purpose: The feasibility of a real-time in vivo dosimeter to detect errors has previously been demonstrated. The purpose of this study was to: (1) quantify the sensitivity of the dosimeter to detect imposed treatment errors under well controlled and clinically relevant experimental conditions, and (2) test a new statistical error decision concept based on full uncertainty analysis. Materials and methods: Phantom studies of two gynecological cancer PDR and one prostate cancer HDR patient treatment plans were performed using tandem ring applicators or interstitial needles. Imposed treatment errors, including interchanged pairs of afterloader guide tubes and 2-20 mm source displacements, were monitored using a real-time fiber-coupled carbon doped aluminum oxide (Al 2 O 3 :C) crystal dosimeter that was positioned in the reconstructed tumor region. The error detection capacity was evaluated at three dose levels: dwell position, source channel, and fraction. The error criterion incorporated the correlated source position uncertainties and other sources of uncertainty, and it was applied both for the specific phantom patient plans and for a general case (source-detector distance 5-90 mm and position uncertainty 1-4 mm). Results: Out of 20 interchanged guide tube errors, time-resolved analysis identified 17 while fraction level analysis identified two. Channel and fraction level comparisons could leave 10 mm dosimeter displacement errors unidentified. Dwell position dose rate comparisons correctly identified displacements ≥5 mm. Conclusion: This phantom study demonstrates that Al 2 O 3 :C real-time dosimetry can identify applicator displacements ≥5 mm and interchanged guide tube errors during PDR and HDR brachytherapy. The study demonstrates the shortcoming of a constant error criterion and the advantage of a statistical error criterion.

  11. Movement of the cervix in after-loading brachytherapy: implications for designing external-beam radiotherapy boost fields.

    Science.gov (United States)

    Hombaiah, U; Blake, P; Bidmead, M

    2006-05-01

    Women with invasive carcinoma of the cervix treated by chemo-radiotherapy and brachytherapy may also receive a pelvic sidewall boost using a midline shield (MLS). The purpose of this study was to assess the usefulness of implanted gold grains in detecting the movement of the cervix caused by the insertion of low-dose-rate brachytherapy applicators, and its implications in designing the MLS. The medical records of 42 women with various stages of cervical carcinoma, who were treated by radical chemo-radiotherapy, were reviewed. All of these women underwent examination under anaesthesia (EUA) and a gold-grain insertion to demarcate the vaginal tumour extent, in the antero-posterior and lateral planes, before starting external-beam radiotherapy. The isocentric orthogonal films (simulator films) of external radiotherapy and brachytherapy were compared to assess the change in position of the gold grains and the consequences for the design of the MLS for parametrial and pelvic sidewall boosts. A significant shift in the position of the gold grains was noted in both the x (lateral) and the y (cranial/caudal) axes. The median shift of the midline, right and left lateral gold grains was 4.5, 5 and 7 mm in the x axis, whereas it was 10, 8 and 9.5 mm in the y axis, respectively. The median shift in the x and y axes was 5.5 and 9 mm, ranging from 1 to 40 mm and 1 to 45 mm, respectively. The gold grains were shifted cranially in 34 (80%) and laterally in 29 (69%) women. Thirty-two women (76.2%) received parametrial boost radiotherapy, of which 25 (59.5%) women had a customised, pear-shaped shield, and the remaining seven (16.7%) had a straight-sided, rectangular MLS. Four women (9.5%) relapsed locally, and three of them had been treated using a customised shield. In two of these four women, there was an absolute under-dosage of the central pelvis at the tip of the intra-uterine tube by 50% of the parametrial boost dose (5.4 Gy/3 fractions/3 days). Insertion of the gold grains

  12. In phantom calibration of a high dose rate remote afterloading device

    International Nuclear Information System (INIS)

    Alfonso, R.; Tolede, P.; Pich, V.

    1995-01-01

    The high dose-rate (HDR) brachytherapy in Cuba is based on soviet made devices type AGAT-V. In order to calibration one of these for clinical use a method based of the different measurement of absorbed dose at the reference point B in a paraffin phantom was developed. The results of the calibration are shown. From these results an analysis was made of the effective doses to prescription point a considering the Lineal-Quadratic model. The clinical results by using the AGAT-V device are displayed in a comparative way

  13. Review of the afterloading techniques in gynecologic radiation therapy

    International Nuclear Information System (INIS)

    Rotte, K.

    1975-01-01

    A review of clinically used afterloading techniques - remote controlled and manually operated ones - is given by tables. The advantages of afterloading techniques are discussed with regard to radiation protection as well as to the therapy of gynecologic carcinomas. (orig.) [de

  14. Postoperative HDR afterloading brachytherapy: Vaginal tumor recurrence rates in patients with endometrial carcinoma dependent on treatment volumes

    International Nuclear Information System (INIS)

    Kloetzer, K.H.; Guenther, R.; Wendt, T.

    1997-01-01

    Patients and Method: At Jena University, Department of Radiotherapy, from 1981 to 1990 108 patients with endometrical carcinoma were postoperatively treated with high dose radiation brachytherapy of the vagina without additional percutaneous radiotherapy. Histology showed more or less differenciated adenocarcinoma in 90% of all patients, all patients were postoperatively stage I or II without proven lymphatic metastases. Dependent on individual figures patients were distributed to 3 different gorups: group A: 4 x 10 Gy, tissue-thickness of 1 cm (vaginal apex) respectively 0.5 cm (lower vaginal walls); group B: 4 x 10 Gy, tissue thickness of 1 cm (upper vaginal wall); group C: 4 x 10 Gy, tissue-thickness of 0.5 cm (both excluding the lower vaginal walls). Results: Both 3-year survival rates (group A: 96.6%, group B: 96.9%, group C: 97.7%) and tumor relapse rates of the vaginal apex (group A: 0, group B: 3.1%, group C: 2.2%) don't show significant differences. No case of local tumor recurrence was seen in the upper 2/3 of the vagina and the pelvic walls. Late side effects concerning bladder and rectum (grade III to IV, EORTC/RTOG) could be minimized by reducing the treatment volume (group A: 6.8%/12.6%, group B: 6,2%/3.1%, group C: 2.2%/0). (orig./AJ) [de

  15. Conventional external beam radiation therapy and high dose rate afterloading brachytherapy as a boost for patients older than 70 years

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Salvajoli, Joao Vitor; Fogaroli, Ricardo Cesar; Novaes, Paulo Eduardo R.S.; Maia, Maria Aparecida Conte; Ferrigno, Robson

    2005-01-01

    The treatment options for patients with non metastatic prostate cancer range from observation, radical prostatectomy, radiation therapy, hormonal therapy to various combination of some to all of them. Objective: we evaluated the impact on biochemical control of disease (bNED), acute and late intestinal (GI) and urological (GU) morbidity for a group of patients older than 70 years presenting initial or locally advanced prostate cancer treated with fractionated high dose rate brachytherapy (HDRB) as a boost to conventional external beam radiation therapy (RT) at the Department of Radiation Oncology from Hospital do Cancer A. C. Camargo, Sao Paulo, Brazil. Methods: a total of 56 patients older than 70 were treated from March, 1997 to June, 2002. All patients had prior to HDRB a course of RT to a median dose of 45 Gy. HDRB doses ranged from 16 Gy to 20 Gy, given in 4 fractions. Results: the median age of the patients was 74.4 years (range 70-83) and the median follow-up 33 months (range 24 to 60). The 5-year actuarial bNED rate was 77%. Acute GU and GI morbidity G1-2 were seen in 17.8% and 7.1% of patients, respectively. Late G1 or G2 GU morbidity was seen in 10.7% of the patients, while late G3 morbidity was observed in 7.1% of the patients, represented by urethral strictures. Conclusion: this group of patients had similar bNED rates when compared to literature, with acceptable morbidity rates. (author)

  16. Postoperative vaginal radiation in endometrial cancer using a remote afterloading technique

    International Nuclear Information System (INIS)

    Mandell, L.; Nori, D.; Anderson, L.; Hilaris, B.

    1985-01-01

    Carcinoma of the endometrium is the most common malignancy of the female genital tract. In early stage endometrial cancer, surgery remains the primary mode of treatment while radiation therapy plays an adjuvant role. Prophylactic vaginal radiation has been shown to reduce significantly the incidence of vaginal recurrences. Between the years 1969-1976, 330 patients with FIGO Stages I and II endometrial cancer were treated according to a standard departmental policy in which 40 Gy of external radiation was given to high risk Stage I and II patients in combination with surgery and intravaginal radiation. With this regimen, the mucosal surface received a total equivalent dose of 40 Gy. These treatments were given on an outpatient basis without the need for any sedation or analgesics. The minimum follow-up was 5 years, with a median follow-up of 8.5 years. The overall pelvic and/or vaginal recurrence rate was 2.7%. The incidence of vaginal complications was 3.7%. The advantages of a remote after loading technique in delivering vaginal vault radiation in endometrial cancer are discussed

  17. Identifying afterloading PDR and HDR brachytherapy errors using real-time fiber-coupled Al2O3:C dosimetry and a novel statistical error decision criterion

    DEFF Research Database (Denmark)

    Kertzscher, Gustavo; Andersen, Claus Erik; Siebert, Frank-André

    2011-01-01

    treatment errors, including interchanged pairs of afterloader guide tubes and 2–20mm source displacements, were monitored using a real-time fiber-coupled carbon doped aluminum oxide (Al2O3:C) crystal dosimeter that was positioned in the reconstructed tumor region. The error detection capacity was evaluated...

  18. Brachytherapy

    Science.gov (United States)

    ... the use of a type of energy, called ionizing radiation, to kill cancer cells and shrink tumors. External ... In all cases of brachytherapy, the source of radiation is encapsulated ... non-radioactive metallic capsule. This prevents the radioactive materials ...

  19. BRIT manual after loading brachytherapy kit for intracavitary: initial experience

    International Nuclear Information System (INIS)

    Aggarwal, Lalit M.; Mandal, Abhijit; Asthana, Anupam K.; Shahi, Uday P.; Pradhan, Satyajit

    2007-01-01

    Brachytherapy continues to serve as an important and rapidly evolving tool in the management of cancer. Technological developments in the last two decades have dramatic impact on the safe practice of brachytherapy. A wide range of brachytherapy sources and equipment are available for new therapeutic possibilities. However, decision making with regard to new brachytherapy facilities are need based and depend on the patient load, socioeconomic status of the patients, and funds available with the institution. Remote afterloading equipments are fast replacing the Manual After Loading (MAL) systems. However, keeping in view the large number of patients, who can not afford expensive treatment, the utility of manual after loading system which is inexpensive, cannot be ignored

  20. Design and construction of a holder to the safety handling of Cs-137 to be used in cervix cancer treatments using intracavitary brachytherapy by afterloading

    International Nuclear Information System (INIS)

    Gonzales, E.; Lea, D.

    1996-01-01

    In venezuelan public hospitals where cervix cancer treatments are performed by means of Cs-137 manual afterloading systems, the handling of the sources is done with two type of holders, metallic and plastic, the plastic holders are pieces of induced serious radio-sanitary problem such as loser of the Cs-137 source and radioactive contamination in the treatment area, this has caused the interruption of the treatments in many hospitals. This interruption had a high social cost because of the thousands women waiting for intracavitary therapy. To start again with the treatments, the metallic holders were required but there were not enough funds in the budget, because of this problem in a short time IVIS'S health physics drew and made a low price source holder. (authors). 2 figs., 2 tabs

  1. Oncentra brachytherapy planning system.

    Science.gov (United States)

    Yang, Jack

    2018-03-27

    In modern cancer management, treatment planning has progressed as a contemporary tool with all the advances in computing power in recent years. One of the advanced planning tools uses 3-dimensional (3D) data sets for accurate dose distributions in patient prescription. Among these planning processes, brachytherapy has been a very important part of a successful cancer management program, offering clinical benefits with specific or combined treatments with external beam therapy. In this chapter, we mainly discussed the Elekta Oncentra planning system, which is the main treatment planning tool for high-dose rate (HDR) modality in our facility and in many other facilities in the United States. HDR is a technically advanced form of brachytherapy; a high-intensity radiation source (3.6 mm in length) is delivered with step motor in submillimeter precision under computer guidance directly into the tumor areas while minimizing injury to surrounding normal healthy tissue. Oncentra planning is the key component to generate a deliverable brachytherapy procedure, which is executed on the microSelectron V3 remote afterloader treatment system. Creating a highly conformal plan can be a time-consuming task. The development of Oncentra software (version 4.5.3) offers a variety of useful tools that facilitate many of the clinical challenging tasks for planning, such as contouring and image reconstruction, as well as rapid planning calculations with dose and dose volume histogram analysis. Oncentra Brachy module creates workflow and optimizes the planning accuracy for wide varieties of clinical HDR treatments, such as skin, gynecologic (GYN), breast, prostate, and many other applications. The treatment file can also be transferred to the afterloader control station for speedy delivery. The design concept, calculation algorithms, and optimization modules presented some key characteristics to plan and treat the patients effectively and accurately. The dose distribution and accuracy of

  2. A new applicator design for endocavitary brachytherapy of cancer in the nasopharynx

    International Nuclear Information System (INIS)

    Levendag, Peter C.; Peters, Rob; Meeuwis, Cees A.; Visch, Leo L.; Sipkema, Dick; Pan, Connie de; Schmitz, Paul I.M.

    1997-01-01

    Introduction: In attempting to improve local tumor control by higher doses of radiation, there has been a resurgence of interest in the implementation of brachytherapy in the management of primary and recurrent cancers of the nasopharynx. Brachytherapy with its steep dose fall-off is of particular interest because of the proximity of critical dose limiting structures. Recent developments in brachytherapy, such as the introduction of pulsed-dose-rate and high-dose-rate computerized afterloaders, have encouraged further evolution of brachytherapy techniques. Materials and methods: We have designed an inexpensive, re-usable and flexible silicone applicator, tailored to the shape of the soft tissues of the nasopharynx, which can be used with either low-dose-rate brachytherapy or high (pulsed)-dose-rate remote controlled afterloaders. Results and conclusions: This Rotterdam nasopharynx applicator proved to be easy to introduce, patient friendly and can remain in situ for the duration of the treatment (2-6 days). The design, technique of application and the first consecutive 5 years of clinical experience in using this applicator are presented

  3. Comparison of the cost between 60Co and 192Ir, as the sources for high-dose-rate remote control afterloading systems (HDR-RALS)

    International Nuclear Information System (INIS)

    Ogata, Hitoshi

    1994-01-01

    High-Dose-Rate remote control afterloading systems (HDR-RALS) installing 60 Co sources have been prevailing currently in Japan. The survey conducted by Japan Isotope Association (JIA) reports that 180 machines are at working condition. Although the wide prevalence of the HDR-RALS, the stable supply of 60 Co is becoming difficult because of the short availability of raw materials. The supply of 60 Co is planned to be terminated in March 1996. In place of 60 Co, 192 Ir is going to be produced in 1996. The size of 192 Ir, which is much smaller than that of 60 Co, may facilitate broader clinical usability. On the other hand, for the reason that the half life of 192 Ir (73.8 days) is much shorter than that of 60 Co (5.27 years), several exchanges of the sources in a year are necessary. This report analyses the difference of the cost between 60 Co and 192 Ir as the sources for HDR-RALS. As the cost of the 60 Co sources is dependent on the distance from Tokyo. Radiation activity, etc., the cost-calculation was done on the basis the 60 Co sources were installed for the HDR-RALS systems in Yamanashi Central Hospital. The total cost of 60 Co is 3,377,000 yen on the data from JIA. According to the half life of 5.27 years, the available duration can be thought as 7 years and the monthly cost be calculated as about 40,000 yen. In case of 192 Ir, the prices for Buchler' system and Nucletron's system are 800,000 yen and 990,000 yen respectively. Concerning the shortness of the half life, an exchange in every 3 months is ideal. Therefore the monthly cost of 192 Ir would be 260,000-330,000 yen. Consequently the cost-ratio for 192 Ir and 60 Co would become 6.7-8.3. The cost of intracavitary irradiation is controlled by the government as 10,000 yen per treatment in Japan. If this setting remains the same for HDR-RALS installing 192 Ir, almost all the facilities of radiation therapy would suffer from the cost-income inbalance in the near future. (author)

  4. Definitive Brachytherapy for Kaposi's Sarcoma

    International Nuclear Information System (INIS)

    Williams, A.; Ezzell, G.; Zalupski, M.; Fontanesi, J.

    1996-01-01

    Purpose: To assess the efficacy and possible complications in patients diagnosed with Kaposi's sarcoma and treated with definitive brachytherapy. Methods and Materials: Between January, 1995 and December, 1995, four patients with Kaposi's sarcoma (KS) were treated with brachytherapy. Three patients, all with positive HIV status were treated using Iridium 192 (Ir-192) sources via a high-dose rate remote afterloader. One patient with endemic KS was treated using the application of catheters loaded with Californium 252. Eight sites were treated and included scalp, feet, nose, penis, hand, neck, and back. Dose rate for Ir-192 was 330cGy/fx to a total dose of 990cGy. The Californium was delivered as 100nGy/b.i.d. to a total dose of 900nGy. Follow-up as ranged from 2-6 months. Results: All four patients remain alive. Seven of eight sites have had complete clinical response and each patient has reported durable pain relief that has not subsided through last follow-up of 1/96. Two of eight sites, both treated with surface mold technique with Californium 252 developed moist desquamation. The remaining six sites did not demonstrate significant toxicity. Conclusion: Brachytherapy can offer Kaposi's sarcoma patients results that are equivalent to external beam radiation therapy, with minimal complications, a shorter treatment time and potential cost effectiveness

  5. Quality assurance of Vari-source high dose rate (HDR) brachytherapy- remote after loader and cost effectiveness of Vari-source HDR- brachytherapy: NORI, Islamabad experience

    International Nuclear Information System (INIS)

    Ahmad, N.; Mahmood, H.; Jafri, S.R.A.

    2004-01-01

    A quality control of Vari-Source high dose rate (HDR) remote after loading brachytherapy machine was carried out and the cost effectiveness of HDR brachytherapy machine was also evaluated considering the cost of ten Iridium-192 wire sources at Nuclear Medicine, Oncology and Radiotherapy Institute (NORI), Islamabad, Pakistan. A total number of 253 intracavitary insertions were done in 98 patients from October 1996 to May 2001. The results of the quality control tests performed during 1996 to 2001 were within the acceptable limits. The cost effectiveness of Vari-Source HDR brachytherapy machine was also evaluated. The average cost per patient was calculated as US$ 491. Small number of patients was treated as the machine was used for gynecologic malignancies only. The objective was to assess the quality control status of HDR brachytherapy machine on patient treatment day, source exchange day and periodic day (monthly basis). It was found that the cost per patient can be minimized if other type of cancer patients are also treated on Vari-Source HDR machine. (author)

  6. Relocation of a nucletron microselectron-HDR brachytherapy system

    Energy Technology Data Exchange (ETDEWEB)

    Bartrum, T; Tran, T; Freeman, N; Morales, J [St Vincents Hospital, Darlinghurst, NSW (Australia)

    2004-12-15

    Full text: For a period of four weeks, our clinical Nucletron microSelectron high dose rate (HDR) brachytherapy system was pulled out of clinical use and relocated to a new building. During this period decommission tests, de-wiring of the treatment unit and its associated safety system (such as radiation detector, emergency off circuits and door interlocks), transportation of all equipment, re-wiring of this equipment in the new location and recommission tests were carried out. The decommission and recommission test program was designed upon consultation with the manufacturer's (Nucletron) acceptance test procedures and work carried out by others. The ACPSEM tolerances for remote afterloaders was used as a guideline. In addition to mandatory dosimetry, positional, workstation database and safety tests, two Australian Standard compliance tests were carried out. The compliance tests involved one for remote afterloaders and another for treatment room design. This testing program was designed and implemented with the aim of ensuring ongoing safe delivery of brachytherapy doses to the patient. The testing program consisted of two parts. The first involved a series of decommissioning tests that consisted of dosimetry tests such as source and check cable positional accuracy and source calibration tests. In addition to these tests an inventory of standard plans, patient records and system configuration information was catalogued. The second part involved a series of recommission tests and involved carrying out dosimetry tests on the brachytherapy system (positional accuracy and calibration tests), simulating common treatment scenarios (prostate, cervical, vaginal and bile duct) and checking standard plans; patient records and system configuration had remained unchanged. During this period, other tests were carried out. These included Nucletron acceptance and preventative maintenance tests, Australian Standards compliance testing and integrity of network transfer of

  7. Relocation of a nucletron microselectron-HDR brachytherapy system

    International Nuclear Information System (INIS)

    Bartrum, T.; Tran, T.; Freeman, N.; Morales, J.

    2004-01-01

    Full text: For a period of four weeks, our clinical Nucletron microSelectron high dose rate (HDR) brachytherapy system was pulled out of clinical use and relocated to a new building. During this period decommission tests, de-wiring of the treatment unit and its associated safety system (such as radiation detector, emergency off circuits and door interlocks), transportation of all equipment, re-wiring of this equipment in the new location and recommission tests were carried out. The decommission and recommission test program was designed upon consultation with the manufacturer's (Nucletron) acceptance test procedures and work carried out by others. The ACPSEM tolerances for remote afterloaders was used as a guideline. In addition to mandatory dosimetry, positional, workstation database and safety tests, two Australian Standard compliance tests were carried out. The compliance tests involved one for remote afterloaders and another for treatment room design. This testing program was designed and implemented with the aim of ensuring ongoing safe delivery of brachytherapy doses to the patient. The testing program consisted of two parts. The first involved a series of decommissioning tests that consisted of dosimetry tests such as source and check cable positional accuracy and source calibration tests. In addition to these tests an inventory of standard plans, patient records and system configuration information was catalogued. The second part involved a series of recommission tests and involved carrying out dosimetry tests on the brachytherapy system (positional accuracy and calibration tests), simulating common treatment scenarios (prostate, cervical, vaginal and bile duct) and checking standard plans; patient records and system configuration had remained unchanged. During this period, other tests were carried out. These included Nucletron acceptance and preventative maintenance tests, Australian Standards compliance testing and integrity of network transfer of

  8. Ultrasonography-guided cobalt-60 brachytherapy for malignant glioma

    International Nuclear Information System (INIS)

    Sakai, Noboru; Takenaka, Katsunobu; Ueda, Tatsuya

    1989-01-01

    Brachytherapy with cobalt-60 source is reported. In this method it is characterized that the source is inserted interstitially with remote control system by after-loading method via outer catheter (using tandem tube), which was established in the center of residual tumor, using ultrasonography guide with trepanation, or intraoperatively put within the dead space after tumor resection. Six cases of deep-seated and recurrent malignant glioma, were treated with this method. A total dose of 20 to 45 Gy (10 to 15 Gy/day for 2 to 3 days) was delivered to the target. Additionally conventional external irradiation was followed. The effect of cobalt-60 brachytherapy on such tumors were favorable especially for well-circumscribed glioma less than 3 cm on CT scan. (author)

  9. Afterloading intracavitary irradiation and expanding stent for malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, Hitoshi; Sakaguchi, Hiroshi; Yoshioka, Tetsuya and others

    1989-02-01

    A double lumen catheter was developed as an apllicator for the remote afterloading (RALS) of /sup 60/Co source for the intracavitary irradiation of an obstructed common bile duct caused by carcinoma of the gallbladder. This was followed by the placement of nylon-covered expandable metallic stents to maintain patency. This combination effectively provided palliation. (author).

  10. High-dose-rate brachytherapy using molds for oral cavity cancer. The technique and its limitations

    International Nuclear Information System (INIS)

    Nishimura, Yasumasa; Yokoe, Yoshihiko; Nagata, Yasushi; Okajima, Kaoru; Nishida, Mitsuo; Hiraoka, Masahiro

    1998-01-01

    With the availability of a high-dose-rate (HDR) remote afterloading device, a Phase I/II protocol was initiated at our institution to assess the toxicity and efficacy of HDR intracavitary brachytherapy, using molds, in the treatment of squamous cell carcinomas of the oral cavity. Eight patients with squamous cell carcinoma of the oral cavity were treated by the technique. The primary sites of the tumors were the buccal mucosa, oral floor, and gingiva. Two of the buccal mucosal cancers were located in the retromolar trigon. For each patient, a customized mold was fabricated, in which two to four afterloading catheters were placed for an 192 Ir HDR source. Four to seven fractions of 3-4 Gy, 5 mm below the mold surface, were given following external radiation therapy of 40-60 Gy/ 2 Gy. The total dose of HDR brachytherapy ranged from 16 to 28Gy. Although a good initial complete response rate of 7/8 (88%) was achieved, there was local recurrence in four of these seven patients. Both of the retromolar trigon tumors showed marginal recurrence. No serious (e.g., ulcer or bone exposure) late radiation damage has been observed thus far in the follow up period of 15-57 months. High-dose-rate brachytherapy using the mold technique seems a safe and useful method for selected early and superficial oral cavity cancer. However, it is not indicated for thick tumors and/or tumors located in the retromolar trigon. (author)

  11. [3-D reconstruction of the breast implants from isocentric stereoscopic x-ray images for the application monitoring and irradiation planning of a remote-controlled interstitial afterloading method].

    Science.gov (United States)

    Löffler, E; Sauer, O

    1988-01-01

    An individual irradiation planning and application monitoring by ISXP is presented for a remote-controlled interstitial afterloading technique using 192Ir wires which is applied in breast-preserving radiotherapy. The errors of reconstruction of the implants are discussed. The consideration of errors for ISXP can be extended to other stereoscopic methods. In this case the quality considerations made by other authors have to be enlarged. The maximum reconstruction error was investigated for a given digitalization precision, focus size, and object blur by patient's movements in dependence on the deviation angle. The optimum deviation angle is about 45 degrees, depending on the importance given to the individual parts and almost without being influenced by the relation between the isocenter-film and the focus-isocenter distances. In case of an optimized deviation angle, a displacement of an implant point of 1 mm leads to a maximum reconstruction error of 2 mm. The dosage is made according to the Paris system. If the circumcircle radius of the application triangle is modified by 1 mm, a dosage modification of 14% will be the consequence in case of very short wires and a small side length. A verification in a phantom showed a positioning error below 0.5 mm. The dosage error is 2% due to the mutual compensation of the direction-isotropic reconstruction errors of the needles the number of which is between seven and nine.

  12. Three-dimensional reconstruction of breast implants based on isocentric stereoscopic X-ray pictures (ISXP) for application monitoring and irradiation planning of a remote-controlled interstitial afterloading method

    Energy Technology Data Exchange (ETDEWEB)

    Loeffler, E.; Sauer, O.

    1988-01-01

    An individual irradiation planning and application monitoring by ISXP is presented for a remote-controlled interstitial afterloading technique using /sup 192/Ir wires which is applied in breast-preserving radiotherapy. The errors of reconstruction of the implants are discussed. The consideration of errors for ISXP can be extended to other stereoscopic methods. In this case the quality considerations made by other authors have to be enlarged. The maximum reconstruction error was investigated for a given digitalization precision, focus size, and object blur by patient's movements in dependence on the deviation angle. The optimum deviation angle is about 45/sup 0/, depending on the importance given to the individual parts and almost without being influenced by the relation between the distance isocenter-film and the distance focus-isocenter. In case of an optimized deviation angle, a displacement of an implant point of 1 mm leads to a maximum reconstruction error of 2 mm. The dosage is made according to the Paris system. If the circumcircle radius of the application triangle is modified by 1 mm, a dosage modification of 14% will be the consequence in case of very short wires and a small side length. A verification in a phantom showed a positioning error below 0.5 mm. The dosage error is 2% due to the mutual compensation of the direction-isotropic reconstruction errors of the needles the number of which is between seven and nine.

  13. Three-dimensional brachytherapy optimization techniques in the treatment of patients with cervix cancer

    International Nuclear Information System (INIS)

    Haie-Meder, C.; Mazeron, R.; Verezesan, O.; Monnier, L.; Vieillot, S.; Dumas, I.; Lhomme, C.; Morice, P.; Barillot, I.

    2009-01-01

    Traditionally, prescription and treatment planning in intracavitary brachytherapy for cervix cancer have used either reference points (mainly points A and B) or reference isodoses (60 Gy according to ICRU recommendations) to report doses to the target volume. Doses to critical organs were reported at bladder and rectum ICRU points. This practice has been supported by a long-standing clinical experience that has yielded an acceptable therapeutic ratio. The recent development of imaging has contributed to the improvement in target and organs at risk knowledge. In 2005 and 2006, the European group of brachytherapy -European Society for therapeutic radiology and oncology (GEC-E.S.T.R.O.) recommendations publications on 3-D based image brachytherapy have defined the different volumes of interest. These recommendations have been validated with intercomparison delineation studies. With the concomitant development of remote after-loading projectors, provided with miniaturized sources, it is now possible to plan radiation doses by adjusting dwell positions and relative dwell time values. These procedures allow better coverage of the targets while sparing O.A.R.. The recent literature data evidence a significant improvement in local control with no increase in complications. Further studies are needed to better define the dose recommended in both tumour and organs at risk. This is one of the goals of the European study on MRI-guided brachytherapy in locally advanced cervical cancer (E.M.B.R.A.C.E.) protocol (meaning of acronym: an international study on MRI-guided brachytherapy in locally advanced cervical cancer). (authors)

  14. Physics and quality assurance for high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Anderson, Lowell L.

    1995-01-01

    Purpose: To review the physical aspects of high dose rate (HDR) brachytherapy, including commissioning and quality assurance, source calibration and dose distribution measurements, and treatment planning methods. Following the introduction of afterloading in brachytherapy, development efforts to make it 'remote' culminated in 1964 with the near-simultaneous appearance of remote afterloaders in five major medical centers. Four of these machines were 'high dose rate', three employing 60Co and one (the GammaMed) using a single, cable-mounted 192Ir source. Stepping-motor source control was added to the GammaMed in 1974, making it the precursor of modern remote afterloaders, which are now suitable for interstitial as well as intracavitary brachytherapy by virtue of small source-diameter and indexer-accessed multiple channels. Because the 192Ir sources currently used in HDR remote afterloaders are supplied at a nominal air-kerma strength of 11.4 cGy cm2 s-1 (10 Ci), are not collimated in clinical use, and emit a significant fraction (15%) of photons at energies greater than 600 keV, shielding and facility design must be undertaken as carefully and thoroughly as for external beam installations. Licensing requirements of regulatory agencies must be met with respect both to maximum permissible dose limits and to the existence and functionality of safety devices (door interlocks, radiation monitors, etc.). Commissioning and quality assurance procedures that must be documented for HDR remote afterloading relate to (1) machine, applicator, guide-tube, and facility functionality checks, (2) source calibration, (3) emergency response readiness, (4) planning software evaluation, and (5) independent checks of clinical dose calculations. Source calibration checks must be performed locally, either by in-air measurement of air kerma strength or with a well ionization chamber calibrated (by an accredited standards laboratory) against an in-air measurement of air kerma strength for the

  15. Surface applicators for high dose rate brachytherapy in AIDS-related kaposi's sarcoma

    International Nuclear Information System (INIS)

    Evans, Michael D.C.; Yassa, Mariam; Podgorsak, Ervin B.; Roman, Ted N.; Schreiner, L. John; Souhami, Luis

    1997-01-01

    Purpose: The development of commercially available surface applicators using high dose rate remote afterloading devices has enabled radiotherapy centers to treat selected superficial lesions using a remote afterloading brachytherapy unit. The dosimetric parameters of these applicators, the clinical implementation of this technique, and a review of the initial patient treatment regimes are presented. Methods and Materials: A set of six fixed-diameter (1, 2, and 3 cm), tungsten/steel surface applicators is available for use with a single stepping-source (Ir-192, 370 GBq) high dose rate afterloader. The source can be positioned either in a parallel or perpendicular orientation to the treatment plane at the center of a conical aperture that sits at an SSD of approximately 15 mm and is used with a 1-mm thick removable plastic cap. The surface dose rates, percent depth dose, and off-axis ratios were measured. A custom-built, ceiling-mounted immobilization device secures the applicator on the surface of the patient's lesion during treatment. Results: Between November 1994, and September 1996, 16 AIDS-related Kaposi's sarcoma patients having a total of 120 lesions have been treated with palliative intent. Treatment sites were distributed between the head and neck, extremity, and torso. Doses ranged from 8 to 20 Gy, with a median dose of 10 Gy delivered in a single fraction. Treatments were well tolerated with minimal skin reaction, except for patients with lesions treated to 20 Gy who developed moderate/severe desquamation. Conclusion: Radiotherapy centers equipped with a high dose rate remote afterloading unit may treat small selected surface lesions with commercially available surface applicators. These surface applicators must be used with a protective cap to eliminate electron contamination. The optimal surface dose appears to be either 10 or 15 Gy depending upon the height of the lesion

  16. Shielding evaluation of a medical linear accelerator vault in preparation for installing a high-dose rate 252Cf remote after-loader

    International Nuclear Information System (INIS)

    Melhus, C. S.; Rivard, M. J.; KurKomelis, J.; Liddle, C. B.; Masse, F. X.

    2005-01-01

    In support of the effort to begin high-dose rate 252 Cf brachytherapy treatments at Tufts-New England Medical Center, the shielding capabilities of a clinical accelerator vault against the neutron and photon emissions from a 1.124 mg 252 Cf source were examined. Outside the clinical accelerator vault, the fast neutron dose equivalent rate was below the lower limit of detection of a CR-39 etched track detector and below 0.14 ± 0.02 μSv h -1 with a proportional counter, which is consistent, within the uncertainties, with natural background. The photon dose equivalent rate was also measured to be below background levels (0.1 μSv h -1 ) using an ionisation chamber and an optically stimulated luminescence dosemeter. A Monte Carlo simulation of neutron transport through the accelerator vault was performed to validate measured values and determine the thermal-energy to low-energy neutron component. Monte Carlo results showed that the dose equivalent rate from fast neutrons was reduced by a factor of 100,000 after attenuation through the vault wall, and the thermal-energy neutron dose equivalent rate would be an additional factor of 1000 below that of the fast neutrons. Based on these findings, the shielding installed in this facility is sufficient for the use of at least 5.0 mg of 252 Cf. (authors)

  17. Pulsed dose rate (PDR) brachytherapy as salvage treatment of locally advanced or recurrent gynecologic cancer

    DEFF Research Database (Denmark)

    Jensen, P T; Roed, H; Engelholm, S A

    1998-01-01

    PURPOSE: Pulsed dose rate (PDR) brachytherapy is a new treatment option permitting dose distribution optimization in interstitial implants. It possesses the advantage of equipment simplification and radiation protection to the staff, compared to the manually afterloading technique. This study pre...

  18. Experience with LDR and MDR brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Okawa, Tomohiko; Okawa, Midori-Kita; Kaneyasu, Yuko; Karasawa, Kumiko; Fukuhara, Noboru

    1996-01-01

    As the brachytherapy dose-rate increases, it is necessary to reduce the total dose or to increase the fraction number with reducing the fraction dose in order not to increase the incidence of the late effect. With the introduction to the Tokyo Women's Medical College, Hospital of a remote afterloading system of Selectron - MDR, delivering dose-rate to point A became approximately twice of that with our classical cesium LDR manual afterloading technique. Material and Methods: Between 1987 to 1993 a total of, previously untreated 74 patients with cervical cancer received MDR brachytherapy using a Selection - MDR. This analysis is therefore of those patients series who underwent radical radioradiotherapy with MDR, 1987-1993, in comparison with the 347 cases who were treated with classical manual LDR afterloading machine, 1969-1986. The treatment was a brachytherapy during external radiotherapy and dos-rate at point A was 160-180 cGy/hour with MDR and 80-90 cGy/hour with LDR. The mean fraction dose was 800-1000 cGy by MDR and 1000-1200 cGy by LDR and fraction number was increased 1-2times in the MDR group with no change of a total dose at point A. Results: The mean age was 63.3 years in the MDR group and 60.2 in the LDR group. In the MDR group, 4 patients were at stage I, 16 stage II, 32 stage III, and 22 stage IV. In the LDR group, 32 were at stage I, 83 stage II, 183 stage III, and 49 stage IV. The medical rate was not significantly different between two groups. The tumor response by manual examination one month after radiotherapy showed no significant difference. The 5-year survival rate for the MDR and LDR groups were 100% : 78% at stage I, 61% : 71% at stage II and 52% : 53% at stage III, with no significant differences. Late complications by severity with grade II-III according to Kottureire's classification were not significantly different in the rectum or bladder. These results suggested that MDR brachytherapy was useful for the patients' QOL as it reduced the

  19. Radiation safety program in a high dose rate brachytherapy facility

    International Nuclear Information System (INIS)

    Rodriguez, L.V.; Hermoso, T.M.; Solis, R.C.

    2001-01-01

    The use of remote afterloading equipment has been developed to improve radiation safety in the delivery of treatment in brachytherapy. Several accidents, however, have been reported involving high dose-rate brachytherapy system. These events, together with the desire to address the concerns of radiation workers, and the anticipated adoption of the International Basic Safety Standards for Protection Against Ionizing Radiation (IAEA, 1996), led to the development of the radiation safety program at the Department of Radiotherapy, Jose R. Reyes Memorial Medical Center and at the Division of Radiation Oncology, St. Luke's Medical Center. The radiation safety program covers five major aspects: quality control/quality assurance, radiation monitoring, preventive maintenance, administrative measures and quality audit. Measures for evaluation of effectiveness of the program include decreased unnecessary exposures of patients and staff, improved accuracy in treatment delivery and increased department efficiency due to the development of staff vigilance and decreased anxiety. The success in the implementation required the participation and cooperation of all the personnel involved in the procedures and strong management support. This paper will discuss the radiation safety program for a high dose rate brachytherapy facility developed at these two institutes which may serve as a guideline for other hospitals intending to install a similar facility. (author)

  20. Impact of 'optimized' treatment planning for tandem and ring, and tandem and ovoids, using high dose rate brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Noyes, William R.; Peters, Nancy E.; Thomadsen, Bruce R.; Fowler, Jack F.; Buchler, Dolores A.; Stitt, Judith A.; Kinsella, Timothy J.

    1995-01-01

    Purpose: Different treatment techniques are used in high dose rate (HDR) remote afterloading intracavitary brachytherapy for uterine cervical cancer. We have investigated the differences between 'optimized' and 'nonoptimized' therapy using both a tandem and ring (T/R) applicator, and a tandem and ovoids (T/O), applicator. Methods and Materials: HDR afterloading brachytherapy using the Madison System for Stage IB cervical cancer was simulated for 10 different patients using both a T/R applicator and a T/O applicator. A treatment course consists of external beam irradiation and five insertions of HDR afterloading brachytherapy. Full dosimetry calculations were performed at the initial insertion for both applicators and used as a reference for the following four insertions of the appropriate applicator. Forty dosimetry calculations were performed to determine the dose delivered to Point M (similar to Point A), Point E (obturator lymph nodes), vaginal surface, bladder, and rectum. 'Optimized' doses were specified to Point M and to the vaginal surface. 'Nonoptimized' doses were specified to Point M only. Using the linear-quadratic equation, calculations have been performed to convert the delivered dose using HDR to the biologically equivalent doses at the conventional low dose rate (LDR) at 0.60 Gy/h. Results: Major differences between 'optimized' and 'nonoptimized' LDR equivalent doses were found at the vaginal surface, bladder, and rectum. Overdoses at the vaginal surface, bladder, and rectum were calculated to be 208%, nil, and 42%, respectively, for the T/R applicator with 'nonoptimization'. However, for the T/O applicator, the overdoses were smaller, being nil, 32%, and 27%, respectively, with 'nonoptimization'. Conclusion: Doses given in high dose rate intracavitary brachytherapy border on tissue tolerance. 'Optimization' of either applicator decreases the risk of a dose that may have potential for complications. Optimization of a tandem and ovoids best ensures

  1. Survey of brachytherapy practice in the United States: a report of the Clinical Research Committee of the American Endocurietherapy Society.

    Science.gov (United States)

    Nag, S; Owen, J B; Farnan, N; Pajak, T F; Martinez, A; Porter, A; Blasko, J; Harrison, L B

    1995-01-01

    To obtain reliable data on the extent of the brachytherapy practice in the United States by conducting a comprehensive survey of all facilities. The Clinical Research Committee of the AES surveyed all 1321 radiation oncology facilities identified in the Patterns of Care Study (PCS) of the American College of Radiology (ACR). Multiple mailings and follow-up were made to obtain a high response rate. Survey responders and nonresponders were compared using chi-square tests. Summary statistics were reported. Of the 1321 facilities, 1054 responded (80%). Hospital-based and larger facilities had a statistically significant higher rate of response. Brachytherapy was being performed at 819 facilities (the median number of procedures = 21-50). Two hundred and two facilities did no brachytherapy. The common isotopes used were 137Cs (705 facilities), 192Ir (585 facilities), 125I (236 facilities), and 131I (194 facilities). The common brachytherapy techniques used were intracavitary (751 facilities), interstitial (536 facilities), intraluminal (310 facilities), and plaques (148 facilities). Remote afterloaded brachytherapy was used at 205 centers as follows: high dose rate (HDR) (164), medium dose rate (MDR) (5), and low dose rate (LDR) (36). Computerized dosimetry was most commonly used (790 facilities), followed by Patterson-Parker (104 facilities) and Quimby (72 facilities). The common sites treated were cervix (701 facilities), endometrium (565 facilities), head and neck (354 facilities), and lung (344 facilities). Data regarding brachytherapy practice has been obtained from a large percentage (80%) of all facilities in the United States. The majority (78-81%) of radiation oncology facilities perform brachytherapy; however, its use is restricted to gynecological implants in many of these centers. The results from this survey will be used to develop a pattern of care study and data registry in brachytherapy.

  2. Tumor hypoxia - A confounding or exploitable factor in interstitial brachytherapy? Effects of tissue trauma in an experimental rat tumor model

    NARCIS (Netherlands)

    van den Berg, AP; van Geel, CAJF; van Hooije, CMC; van der Kleij, AJ; Visser, AG

    2000-01-01

    Purpose: To evaluate the potential effects of tumor hypoxia induced by afterloading catheter implantation on the effectiveness of brachytherapy in a rat tumor model. Methods and Materials: Afterloading catheters (4) Here implanted in subcutaneously growing R1M rhabdomyosarcoma in female Wag/Rij

  3. Radiation safety program in high dose rate brachytherapy facility at INHS Asvini

    Directory of Open Access Journals (Sweden)

    Kirti Tyagi

    2014-01-01

    Full Text Available Brachytherapy concerns primarily the use of radioactive sealed sources which are inserted into catheters or applicators and placed directly into tissue either inside or very close to the target volume. The use of radiation in treatment of patients involves both benefits and risks. It has been reported that early radiation workers had developed radiation induced cancers. These incidents lead to continuous work for the improvement of radiation safety of patients and personnel The use of remote afterloading equipment has been developed to improve radiation safety in the delivery of treatment in brachytherapy. The widespread adoption of high dose rate brachytherapy needs appropriate quality assurance measures to minimize the risks to both patients and medical staff. The radiation safety program covers five major aspects: quality control, quality assurance, radiation monitoring, preventive maintenance, administrative measures and quality audit. This paper will discuss the radiation safety program developedfor a high dose rate brachytherapy facility at our centre which may serve as a guideline for other centres intending to install a similar facility.

  4. Brachytherapy of endometrial cancers

    International Nuclear Information System (INIS)

    Peiffert, D.; Hoffstetter, S.; Charra-Brunaud, C.

    2003-01-01

    Endometrial adenocarcinomas rank third as tumoral sites en France. The tumors are confined to the uterus in 80% of the cases. Brachytherapy has a large place in the therapeutic strategy. The gold standard treatment remains extra-fascial hysterectomy with bilateral annexiectomy and bilateral internal iliac lymph node dissection. However, after surgery alone, the rate of locoregional relapses reaches 4-20%, which is reduced to 0-5% after postoperative brachytherapy of the vaginal cuff. This postoperative brachytherapy is delivered as outpatients treatment, by 3 or 4 fractions, at high dose rate. The utero-vaginal preoperative brachytherapy remains well adapted to the tumors which involve the uterine cervix. Patients presenting a localized tumor but not operable for general reasons (< 10%) can be treated with success by exclusive irradiation, which associates a pelvic irradiation followed by an utero-vaginal brachytherapy. A high local control of about 80-90% is obtained, a little lower than surgery, with a higher risk of late complications. Last but not least, local relapses in the vaginal cuff, or in the perimeatic area, can be treated by interstitial salvage brachytherapy, associated if possible with external beam irradiation. The local control is reached in half of the patients, but metastatic dissemination is frequent. We conclude that brachytherapy has a major role in the treatment of endometrial adenocarcinomas, in combination with surgery, or with external beam irradiation for not operable patients or in case of local relapses. It should use new technologies now available including computerized after-loaders and 3D dose calculation. (authors)

  5. SU-E-T-242: Design of a Novel Afterloader Clearance QA Device for Biliary HDR Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Mullins, JP; Deufel, CL [Mayo Clinic, Rochester, MN (United States)

    2015-06-15

    Purpose: Bile duct cancer affects 2–3 thousand people annually in the United States. Radiation therapy has been shown to double median survival, with combined external beam and intraluminal high dose-rate (HDR) brachytherapy being most effective. Endoscopic retrograde cholangiopancreatography (ERCP) biliary HDR, a less-invasive alternative to trans-hepatic brachytherapy, is delivered through a catheter that travels a tortuous path from nose to bile duct, requiring wire drive force and dexterity beyond typical afterloader performance specifications. Thus, specific afterloader quality assurance(QA) is recommended for this procedure. Our aim was to create a device and process for Varisource afterloader clearance QA with objectives that it be quantitative and can monitor afterloader performance over time, compare performance between two distinct afterloaders and potentially Result in a predictive nomogram for patient-specific clearance. Methods: Based on retrospective reconstruction of 20 ERCP patient anatomies, we designed a phantom to test afterloader ability to drive the source wire along an intended treatment path. The ability of the afterloader to fully extend the intended treatment path is a function of number and diameters of turns. We have determined experimentally that relative position of the turns does not impact performance. Results: Both patient and QA paths involve three common turns/loops: a large turn representing the stomach(10.8cm±2.0cm), an elliptical loop representing the duodenum(7.3cm±1.5cmx4.8cm±0.7cm), and a final turn at the end of the bile duct that may be tight for some patient-specific anatomies and absent in others(3.7cm±0.7cm, where present). Our phantom design uses anatomical average turn diameters for the stomach and duodenum then terminates in a turn of quantitatively selectable diameter. The smallest final turn diameter that an afterloader can pass is recorded as the QA parameter. Conclusion: With this device and QA process, we

  6. Physics and quality assurance for brachytherapy - Part I: High dose rates

    International Nuclear Information System (INIS)

    Anderson, Lowell L.

    1997-01-01

    Purpose: To review the physical aspects of high dose rate (HDR) brachytherapy, including commissioning and quality assurance, source calibration and dose distribution measurements, and treatment planning methods. Following the introduction of afterloading in brachytherapy, development efforts to make it 'remote' culminated in 1964 with the near-simultaneous appearance of remote afterloaders in five major medical centers. Four of these machines were 'high dose rate', three employing 60Co and one (the GammaMed) using a single, cable-mounted 192Ir source. Stepping-motor source control was added to the GammaMed in 1974, making it the precursor of modern remote afterloaders, which are now suitable for interstitial, well as intracavitary brachytherapy by virtue of small source-diameter and indexer-accessed multiple channels. Because the 192Ir sources currently used in HDR remote afterloaders are supplied at a nominal air-kerma strength of 11.4 cGy cm2 s-1 (10 Ci), are not collimated in clinical use, and emit a significant fraction (15%) of photons at energies greater than 600 keV, shielding and facility design must be undertaken as carefully and thoroughly as for external beam installations. Licensing requirements of regulatory agencies must be met with respect both to maximum permissible dose limits and to the existence and functionality of safety devices (door interlocks, radiation monitors, etc.). Commissioning and quality assurance procedures that must be documented for HDR remote afterloading relate to (1) machine, applicator, guide-tube, and facility functionality checks, (2) source calibration, (3) emergency response readiness, (4) planning software evaluation, and (5) independent checks of clinical dose calculations. Source calibration checks must be performed locally, either by in-air measurement of air kerma strength or with a well ionization chamber calibrated (by an accredited standards laboratory) against an in-air measurement of air kerma strength for the

  7. Radiobiological equivalent of low/high dose rate brachytherapy and evaluation of tumor and normal responses to the dose.

    Science.gov (United States)

    Manimaran, S

    2007-06-01

    The aim of this study was to compare the biological equivalent of low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy in terms of the more recent linear quadratic (LQ) model, which leads to theoretical estimation of biological equivalence. One of the key features of the LQ model is that it allows a more systematic radiobiological comparison between different types of treatment because the main parameters alpha/beta and micro are tissue-specific. Such comparisons also allow assessment of the likely change in the therapeutic ratio when switching between LDR and HDR treatments. The main application of LQ methodology, which focuses on by increasing the availability of remote afterloading units, has been to design fractionated HDR treatments that can replace existing LDR techniques. In this study, with LDR treatments (39 Gy in 48 h) equivalent to 11 fractions of HDR irradiation at the experimental level, there are increasing reports of reproducible animal models that may be used to investigate the biological basis of brachytherapy and to help confirm theoretical predictions. This is a timely development owing to the nonavailability of sufficient retrospective patient data analysis. It appears that HDR brachytherapy is likely to be a viable alternative to LDR only if it is delivered without a prohibitively large number of fractions (e.g., fewer than 11). With increased scientific understanding and technological capability, the prospect of a dose equivalent to HDR brachytherapy will allow greater utilization of the concepts discussed in this article.

  8. Californium-252 radiotherapy sources for interstitial afterloading

    International Nuclear Information System (INIS)

    Permar, P.H.; Walker, V.W.

    1976-01-01

    Californium-252 neutron sources for interstitial afterloading were developed to investigate the value of this radionuclide in cancer therapy. Californium-252 seed assemblies contain essentially point sources of 252 Cf permanently sealed on 1-cm centers within a flexible plastic tube. The seed assemblies are fabricated with remotely operated, specially designed machines. The fabrication process involves the production of a Pt-10 percent Ir-clad wire with a 252 Cf 2 O 3 -Pd cermet core. The wire is swaged and drawn to size, cut to length, and welded in a Pt-10 percent Ir capsule 0.8 mm in diameter and 6 mm long. Each seed capsule contains approximately 0.5 microgram of 252 Cf. Because the effective half-life of 252 Cf is 2.6 years, the seed assemblies are not disposable and must be reused until their activities have decreased to unsuitable levels. The flexible plastic components must therefore have sufficient resistance to radiation damage to survive the neutron-plus-gamma radiation from 252 Cf. On the basis of accelerated irradiation tests with a large 252 Cf source, a recently developed fluoropolymer, ''Tefzel'' (trademark of E. I. du Pont de Nemours and Company) has adequate radiation resistance for this application. Californium-252 seed assembly systems are loaned by the United States Energy Research and Development Administration for clinical investigations under a protocol of the Radiation Therapy Oncology Group, U.S. National Cancer Institute

  9. 1251 seed calibration using afterloading equipment SeedSelectron. Practical solution to meet the recommendations of the AAPM

    International Nuclear Information System (INIS)

    Perez-Calatayud, J.; Richart, J.; Perez-Garcia, J.; Guirado, D.; Ballester, F.; Rodriguez, S.; Santos, M.; Depiaggio, M.; Carmona, V.; Lliso, F.; Camacho, C.; Pujades, M. C.

    2011-01-01

    SeedSelectron is a system used in the afterloader permanent implant brachytherapy seeds 1-125 interstitial prostate. Two aspects are critical when you can meet the recommendations of the AAPM: a practical difficulty to check the quantity of seed required, and the great uncertainty of all measured diodes. The purpose of this paper is to present a practical solution that has been adopted to implement the recommendations of the AAPM

  10. Current Brachytherapy Quality Assurance Guidance: Does It Meet the Challenges of Emerging Image-Guided Technologies?

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    2008-01-01

    In the past decade, brachytherapy has shifted from the traditional surgical paradigm to more modern three-dimensional image-based planning and delivery approaches. The role of intraoperative and multimodality image-based planning is growing. Published American Association of Physicists in Medicine, American College of Radiology, European Society for Therapeutic Radiology and Oncology, and International Atomic Energy Agency quality assurance (QA) guidelines largely emphasize the QA of planning and delivery devices rather than processes. These protocols have been designed to verify compliance with major performance specifications and are not risk based. With some exceptions, complete and clinically practical guidance exists for sources, QA instrumentation, non-image-based planning systems, applicators, remote afterloading systems, dosimetry, and calibration. Updated guidance is needed for intraoperative imaging systems and image-based planning systems. For non-image-based brachytherapy, the American Association of Physicists in Medicine Task Group reports 56 and 59 provide reasonable guidance on procedure-specific process flow and QA. However, improved guidance is needed even for established procedures such as ultrasound-guided prostate implants. Adaptive replanning in brachytherapy faces unsolved problems similar to that of image-guided adaptive external beam radiotherapy

  11. Clinical outcome of high-dose-rate interstitial brachytherapy in patients with oral cavity cancer

    International Nuclear Information System (INIS)

    Lee, Sung Uk; Cho, Kwan Ho; Moon, Sung Ho; Choi, Sung Weon; Park, Joo Yong; Yun, Tak; Lee, Sang Hyun; Lim, Young Kyung; Jeong, Chi Young

    2014-01-01

    To evaluate the clinical outcome of high-dose-rate (HDR) interstitial brachytherapy (IBT) in patients with oral cavity cancer. Sixteen patients with oral cavity cancer treated with HDR remote-control afterloading brachytherapy using 192Ir between 2001 and 2013 were analyzed retrospectively. Brachytherapy was administered in 11 patients as the primary treatment and in five patients as salvage treatment for recurrence after the initial surgery. In 12 patients, external beam radiotherapy (50-55 Gy/25 fractions) was combined with IBT of 21 Gy/7 fractions. In addition, IBT was administered as the sole treatment in three patients with a total dose of 50 Gy/10 fractions and as postoperative adjuvant treatment in one patient with a total of 35 Gy/7 fractions. The 5-year overall survival of the entire group was 70%. The actuarial local control rate after 3 years was 84%. All five recurrent cases after initial surgery were successfully salvaged using IBT +/- external beam radiotherapy. Two patients developed local recurrence at 3 and 5 months, respectively, after IBT. The acute complications were acceptable (< or =grade 2). Three patients developed major late complications, such as radio-osteonecrosis, in which one patient was treated by conservative therapy and two required surgical intervention. HDR IBT for oral cavity cancer was effective and acceptable in diverse clinical settings, such as in the cases of primary or salvage treatment.

  12. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1997-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume -- Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) -- Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  13. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1996-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume --Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) --Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  14. Implementation of microsource high dose rate (mHDR) brachytherapy in developing countries

    International Nuclear Information System (INIS)

    2001-11-01

    Brachytherapy using remote afterloading of a single high dose rate 192 Ir microsource was developed in the 1970s. After its introduction to clinics, this system has spread rapidly among developed Member States and has become a highly desirable modality in cancer treatment. This technique is now gradually being introduced to the developing Member States. The 192 Ir sources are produced with a high specific activity. This results in a high dose rate (HDR) to the tumour and shorter treatment times. The high specific activity simultaneously results in a much smaller source (so-called micro source, around I mm in diameter) which may be easily inserted into tissue through a thin delivery tube, the so-called interstitial treatment, as well as easily inserted into body cavities, the so-called intracavitary or endoluminal treatment. Another advantage is the ability to change dwell time (the time a source remains in one position) of the stepping source which allows dose distribution to match the target volume more closely. The purpose of this TECDOC is to advise radiation oncologists, medical physicists and hospital administrators in hospitals which are planning to introduce 192 Ir microsource HDR (mHDR) remote afterloading systems. The document supplements IAEA-TECDOC-1040, Design and Implementation of a Radiotherapy Programme: Clinical, Medical Physics, Radiation Protection and Safety Aspects, and will facilitate implementation of this new brachytherapy technology, especially in developing countries. The operation of the system, 'how to use the system', is not within the scope of this document. This TECDOC is based on the recommendations of an Advisory Group meeting held in Vienna in April 1999

  15. Dosimetric advancement of high-dose-rate after-loading 192Ir source

    International Nuclear Information System (INIS)

    Zhang Shuxu; Li Wenhua; Xu Hairong

    2004-01-01

    High-dose-rate (HDR) 192 Ir source is a nuclide commonly used in the brachytherapy system. The basic dosimetry data of the near source area is usually measured by pin ion chambers or TLD techniques, but these methods have a lower spatial resolution than Electron spin resonance (ESR) dosimetry which has a spatial resolution of 156 μm, and the Monte Carlo photon transport simulations are taken as the golden standard of those measures. The precision in two-dimensional dose distribution measured by GafChromic film is reported to be 1.0%. In vivo dosimetry using TLD during HDR intracavitary after-loading brachytherapy is a good predictor of late rectal complications. The accuracy of magnetic resonance imaging (MRI) Fricke-gel dosimetry for three-dimensional dose distribution is about 2.5% with a spatial resolution of 1.56 mm. The optical computed tomography polymer gel dosimetry has a unique advance than MRI gel dosimetry

  16. Three-dimensional brachytherapy optimization techniques in the treatment of patients with cervix cancer; Apport des techniques de curietherapie optimisee grace a l'imagerie tridimensionnelle dans la prise en charge des patientes atteintes d'un cancer du col uterin

    Energy Technology Data Exchange (ETDEWEB)

    Haie-Meder, C.; Mazeron, R.; Verezesan, O.; Monnier, L.; Vieillot, S. [Institut Gustave-Roussy, Service de Curietherapie, 94 - Villejuif (France); Dumas, I. [Institut Gustave-Roussy, Service de Physique, 94 - Villejuif (France); Lhomme, C. [Institut Gustave-Roussy, Service d' Ooncologie Gynecologique, 94 - Villejuif (France); Morice, P. [Institut Gustave-Roussy, Service de Chirurgie Oncologique, 94 - Villejuif (France); Barillot, I. [Centre Regional Universitaire de Cancerologie Henry-S.-Kaplan, Hopital Bretonneau, CHU de Tours, 37 - Tours (France); Universite Francois-Rabelais, 37 - Tours (France)

    2009-10-15

    Traditionally, prescription and treatment planning in intracavitary brachytherapy for cervix cancer have used either reference points (mainly points A and B) or reference isodoses (60 Gy according to ICRU recommendations) to report doses to the target volume. Doses to critical organs were reported at bladder and rectum ICRU points. This practice has been supported by a long-standing clinical experience that has yielded an acceptable therapeutic ratio. The recent development of imaging has contributed to the improvement in target and organs at risk knowledge. In 2005 and 2006, the European group of brachytherapy -European Society for therapeutic radiology and oncology (GEC-E.S.T.R.O.) recommendations publications on 3-D based image brachytherapy have defined the different volumes of interest. These recommendations have been validated with intercomparison delineation studies. With the concomitant development of remote after-loading projectors, provided with miniaturized sources, it is now possible to plan radiation doses by adjusting dwell positions and relative dwell time values. These procedures allow better coverage of the targets while sparing O.A.R.. The recent literature data evidence a significant improvement in local control with no increase in complications. Further studies are needed to better define the dose recommended in both tumour and organs at risk. This is one of the goals of the European study on MRI-guided brachytherapy in locally advanced cervical cancer (E.M.B.R.A.C.E.) protocol (meaning of acronym: an international study on MRI-guided brachytherapy in locally advanced cervical cancer). (authors)

  17. [Developments in brachytherapy].

    Science.gov (United States)

    Ikeda, H

    1995-09-01

    Brachytherapy is one of the ideal methods of radiotherapy because of the concentration of a high dose on the target. Recent developments, including induction of afterloading method, utilization of small-sized high-activity sources such as Iridium-192, and induction of high technology and computerization, have made for shortening of irradiation time and source handling, which has led to easier management of the patient during treatment. Dose distribution at high dose rate (HDR) is at least as good as that of low dose rate (LDR), and selection of fractionation and treatment time assures even greater biological effects on hypoxic tumor cells than LDR. Experience with HDR brachytherapy in uterine cervix cancer using Cobalt-60 during the past 20 years in this country has gradually been evaluated in U.S. and Europe. The indications for HDR treatment have extended to esophagus, bronchus, bile duct, brain, intraoperative placement of source guide, and perineal region using templates, as well as the conventional use for uterus, tongue and so on.

  18. Radiological protection of patients in brachytherapy

    International Nuclear Information System (INIS)

    Sacc, Ricardo; Herrero, Flavia

    2008-01-01

    Full text: The prefix 'brachy' means short-range, so brachytherapy is the administration of radiation therapy using small radioactive sources in the form of needles, tubes, wires or seeds, which are placed within the tumor -interstitial form- or very near of it, superficially or in an endo-cavity form. This technique, which was limited by the size of the primary tumor, has the advantage, that the radiation, can be adjusted to the size and shape of the tumor volume and the radioisotope used, - short range -, is selected with the criteria of getting the dose in the organs at risk, as low as possible, making what it is known as conformal radiotherapy. Radioactive sources may be permanent or temporary implants. The application of radioactive material, can be manually or automatically. In the first case, a major breakthrough from the radioprotection point of view, was the use of afterloading devices, methodology highly recommended to reduce the radiation exposure to staff. With the development of technology, remotely controlled afterloading devices were introduced, which in addition to complying with the above requirement, allow the source to move in different positions along catheters housed in one or more channels, making therapeutic brachytherapy treatments in tumor volumes possible, that due to its length, decades ago would have been an unthinkable deal. In all cases, sources, which may vary from the 3 mm in length, 125 Iodine or 198 Gold seeds, to extensive wires of 192 Iridium, are encapsulated for two main purposes: preventing leakage of radioactive material and absorption of unwanted radiation, alpha and beta, produced by the radioactive decay. Consequently, it should be highly unlikely that the radioactive material, could be lost or located in the patient, in a different place of the one that was planned. However, history shows us the opposite. Its is known the kind of deterministic effect that radiation is going to produce in the tumor, where the severity of

  19. Development and implementation of a remote audit tool for high dose rate (HDR) Ir-192 brachytherapy using optically stimulated luminescence dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Kevin E.; Kry, Stephen F.; Howell, Rebecca M.; Followill, David [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas 77030 (United States); Alvarez, Paola; Lawyer, Ann [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States)

    2013-11-15

    Purpose: The aim of this work was to create a mailable phantom with measurement accuracy suitable for Radiological Physics Center (RPC) audits of high dose-rate (HDR) brachytherapy sources at institutions participating in National Cancer Institute-funded cooperative clinical trials. Optically stimulated luminescence dosimeters (OSLDs) were chosen as the dosimeter to be used with the phantom.Methods: The authors designed and built an 8 × 8 × 10 cm{sup 3} prototype phantom that had two slots capable of holding Al{sub 2}O{sub 3}:C OSLDs (nanoDots; Landauer, Glenwood, IL) and a single channel capable of accepting all {sup 192}Ir HDR brachytherapy sources in current clinical use in the United States. The authors irradiated the phantom with Nucletron and Varian {sup 192}Ir HDR sources in order to determine correction factors for linearity with dose and the combined effects of irradiation energy and phantom characteristics. The phantom was then sent to eight institutions which volunteered to perform trial remote audits.Results: The linearity correction factor was k{sub L}= (−9.43 × 10{sup −5}× dose) + 1.009, where dose is in cGy, which differed from that determined by the RPC for the same batch of dosimeters using {sup 60}Co irradiation. Separate block correction factors were determined for current versions of both Nucletron and Varian {sup 192}Ir HDR sources and these vendor-specific correction factors differed by almost 2.6%. For the Nucletron source, the correction factor was 1.026 [95% confidence interval (CI) = 1.023–1.028], and for the Varian source, it was 1.000 (95% CI = 0.995–1.005). Variations in lateral source positioning up to 0.8 mm and distal/proximal source positioning up to 10 mm had minimal effect on dose measurement accuracy. The overall dose measurement uncertainty of the system was estimated to be 2.4% and 2.5% for the Nucletron and Varian sources, respectively (95% CI). This uncertainty was sufficient to establish a ±5% acceptance

  20. Development and implementation of a remote audit tool for high dose rate (HDR) Ir-192 brachytherapy using optically stimulated luminescence dosimetry

    International Nuclear Information System (INIS)

    Casey, Kevin E.; Kry, Stephen F.; Howell, Rebecca M.; Followill, David; Alvarez, Paola; Lawyer, Ann

    2013-01-01

    Purpose: The aim of this work was to create a mailable phantom with measurement accuracy suitable for Radiological Physics Center (RPC) audits of high dose-rate (HDR) brachytherapy sources at institutions participating in National Cancer Institute-funded cooperative clinical trials. Optically stimulated luminescence dosimeters (OSLDs) were chosen as the dosimeter to be used with the phantom.Methods: The authors designed and built an 8 × 8 × 10 cm 3 prototype phantom that had two slots capable of holding Al 2 O 3 :C OSLDs (nanoDots; Landauer, Glenwood, IL) and a single channel capable of accepting all 192 Ir HDR brachytherapy sources in current clinical use in the United States. The authors irradiated the phantom with Nucletron and Varian 192 Ir HDR sources in order to determine correction factors for linearity with dose and the combined effects of irradiation energy and phantom characteristics. The phantom was then sent to eight institutions which volunteered to perform trial remote audits.Results: The linearity correction factor was k L = (−9.43 × 10 −5 × dose) + 1.009, where dose is in cGy, which differed from that determined by the RPC for the same batch of dosimeters using 60 Co irradiation. Separate block correction factors were determined for current versions of both Nucletron and Varian 192 Ir HDR sources and these vendor-specific correction factors differed by almost 2.6%. For the Nucletron source, the correction factor was 1.026 [95% confidence interval (CI) = 1.023–1.028], and for the Varian source, it was 1.000 (95% CI = 0.995–1.005). Variations in lateral source positioning up to 0.8 mm and distal/proximal source positioning up to 10 mm had minimal effect on dose measurement accuracy. The overall dose measurement uncertainty of the system was estimated to be 2.4% and 2.5% for the Nucletron and Varian sources, respectively (95% CI). This uncertainty was sufficient to establish a ±5% acceptance criterion for source strength audits under a

  1. Quality control of 192Ir high dose rate after loading brachytherapy dose veracity

    International Nuclear Information System (INIS)

    Feng Zhongsu; Xu Xiao; Liu Fen

    2008-01-01

    Recently, 192 Ir high dose rate (HDR) afterloading are widely used in brachytherapy. The advantage of using HDR systems over low dose rate systems are shorter treatment time and higher fraction dose. To guarantee the veracity of the delivery dose, several quality control methods are deseribed in this work. With these we can improve the position precision, time precision and dose precision of the brachytherapy. (authors)

  2. Endobronchial and endoesophageal high dose rate brachytherapy for malignant airway and digestive tract obstructions

    International Nuclear Information System (INIS)

    Mehta, Minesh P.

    1996-01-01

    With an annual incidence of more than 160,000 cases and a local failure rate between 30-50%, endobronchial occlusion seen with lung cancer is a common and potentially life-threatening complication. Several methods of managing this exist and recently endobronchial brachytherapy has been used extensively as a consequence of the development of fiberoptic bronchoscopy and high dose rate remote afterloading technology. Procedurally, one or more afterloading catheters are inserted in the involved portions of the tracheobronchial tree through fiberoptic guidance. Treatment techniques range from 1-4 applications fractionated over several weeks or given over 2 days with a single insertion procedure. Almost all procedures are currently performed in the outpatient setting. The major application of this technology is in the palliation of occlusive symptomatology. Clinical improvement ranges from 50-100%, radiographic reaeration ranges from 46-88% and bronchoscopic responses ranges from 59-100%. Symptomatic relief is usually quite durable with more than 70% of the patients' remaining life-time rendered symptom-free and symptom-improved. Recently, this modality has been explored for its curative potential as a boost following external beam radiotherapy. It is clear from these series, that in selected patients, endobronchial boost produces significant reaeration and sparing of lung volume from subsequent external radiation, and a few cases may even become resectable. Demonstration of the survival advantage will, however, require larger clinical trials with adequate controls. Some reports have suggested an unacceptably high rate of fatal hemoptysis following HDR endobronchial brachytherapy. Review of the world literature suggests that fatal hemoptysis rates range from 0-50% with an average of about 8%, comparable to an average of 5% with low dose rate brachytherapy. Other recognized complications include fistulae and radiation bronchitis. Because the majority of patients with

  3. Pelvic interstitial brachytherapy - improving the therapeutic ratio with magnetic resonance imaging and optimization

    International Nuclear Information System (INIS)

    Swift, Patrick S.; Hricak, Hedvig; Forstner, Rosemary; Powell, C. Bethan; Purser, Phil; Weaver, Keith; Phillips, Theodore L.

    1996-01-01

    Introduction Interstitial brachytherapy in the pelvic region is often hampered by the radiation oncologist's inability to precisely differentiate tumor versus normal tissue during the planning and implantation procedures, often resulting in either excessive or incomplete coverage of tumor volume. The marked improvement in pelvic imaging seen with magnetic resonance, in conjunction with isodose optimization programs for remote-afterloading units, has created an opportunity to significantly improve the therapeutic ratio. Methods From 1992-1995, 23 interstitial perineal templates were performed in 22 patients with pelvic malignancies, using the pulsed low-dose-rate Selectron with dose optimization. MR imaging was performed immediately prior to the implant, with a MUPIT placed against the perineum and a vaginal obturator in place. These images were used for tumor volume measurements, determination of the number, depth and angle of needles required for the implant, and identification of position of normal tissues (rectum, small bowel, bladder) relative to the tumor. After implantation of stainless steel needles, orthogonal radiographs were obtained for isodose calculation, and planning carried out with isodose optimization. Patients were followed closely on a routine schedule, until time of last visit or until death. Every effort possible was made to assess local disease status at time of death. Results Sixteen patients with primary disease (14 cervix, 1 vulva, 1 vagina) and 6 with recurrent (2 with prior radiation) were implanted, all but 3 with curative intent. Nine patients with advanced cervix or vulvar cancer received concomitant chemotherapy (5FU + platinum or mitomycin-C) with the external beam therapy. At a median follow-up of 18.1 months for all cases, only three patients have failed locally for an actuarial local control of 85% at 1.5 years. Nine patients are alive and free of disease, 8 are alive with distant disease only (mean follow-up of 19.1 months), 2

  4. Radiotherapy of Teikyo University. Second report. Experience and the current status at Itabashi Hospital. Brachytherapy

    International Nuclear Information System (INIS)

    Ogata, Hitoshi; Yokokawa, Tokuzo; Shirai, Tatsuo; Furui, Shigeru

    2005-01-01

    To answer the big trend of information disclosure, we are trying to report the experience and the current status of Radiotherapy in Teikyo University. Since 1974, Teikyo University has installed a High-Dose-Rate Remote Afterloading System (HDR RALS) at Itabashi Hospital for brachytherapy. We analyzed the total cases comprehensively in this paper. There were 421 cases treated by Ralstron (Shimazu Co.) between 1974 and 1995 and 128 cases treated additionally between the renewal by Microselectron (Nucletron Co.) and the end of 2002. For several years from the beginning, the number of cases treated by Ralstron had been 30-35 cases annually, but since 1987, the number decreased markedly to fewer than 10 cases per year. After the installation of Microselectron, the number increased gradually to 15 cases per year. Gynecologic tumors accounted for 88.5% of the total cases, namely 96.9% by Ralstron and 60.1% by Microselectron. The others treated by Microselectron were 27 cases with Head and Neck tumors, and 21 cases with digestive tract tumors. To increase the number of the patients for brachytherapy, we should continue to open our current status, and make close relationships between the neighbor hospitals and Teikyo Hospital. (author)

  5. The relative efficacy of HDR and LDR interstitial brachytherapy in squamous cell carcinoma of vagina

    International Nuclear Information System (INIS)

    Demanes, D. J.; Hsu, I-C.; Lin, S.; Ewing, T.; Rodriguez, R.

    1996-01-01

    Introduction: Beginning in 1982 we performed low dose rate (LDR) interstitial template brachytherapy (ISTB) for carcinoma of the vagina. High dose rate (HDR) remote afterloading has been used exclusively since 1991. We compare the results LDR and HDR brachytherapy. Material and Methods: Between 1982 and 1994, 30 patients with primary squamous cell carcinoma of vagina received external beam radiotherapy (EBRT) and brachytherapy. The AJCC stage distribution was 3 stage I, 25 stage II, and 2 stage III. The average central pelvic EBRT dose was 35 Gy. Pelvic side wall EBRT doses ranged from 45 to 50.4 Gy. Nineteen patients had LDR treatment; 3 intracavitary brachytherapy (ICB) and 16 ISTB. Eleven patients had HDR treatment; 2 ICB and 9 ISB. The average dose delivered by LDR was 41.2 Gy usually in 2 fractions, and by HDR 32.5 Gy in 6 fractions of 500-550 cGy. Local failures were confirmed pathologically. The absolute survival (AS) and relapse-free survival (RFS) were calculated using Kaplan-Meier method and compared with logrank statistics. Results: The mean follow-up was 77 months for LDR and 23 months for HDR. Local and regional control was achieved in 90% (27/30) of the patients. Three year AS was 84% and RFS was 87%. There was no significant difference between LDR and HDR in AS, RFS or local-regional control, (log rank p=0.85, p=0.12 and p=0.35 respectively). The single HDR local failure presented in a patient with extensive stage II disease who declined ISTB. There were fewer complications following HDR. The 1 case of extensive vaginal necrosis and the 3 cases of rectovaginal fistula that required surgery occurred only with LDR brachytherapy. Discussion: Excellent local and regional control of carcinoma of the vagina can be achieved by administering limited doses of external radiation and brachytherapy. Interstitial template implants are the best means of encompassing paravaginal disease while sparing the adjacent uninvolved normal tissues from high doses of

  6. Risk analysis of brachytherapy events

    International Nuclear Information System (INIS)

    Buricova, P.; Zackova, H.; Hobzova, L.; Novotny, J.; Kindlova, A.

    2005-01-01

    For prevention radiological events it is necessary to identify hazardous situation and to analyse the nature of committed errors. Though the recommendation on the classification and prevention of radiological events: Radiological accidents has been prepared in the framework of Czech Society of Radiation Oncology, Biology and Physics and it was approved by Czech regulatory body (SONS) in 1999, only a few reports have been submitted up to now from brachytherapy practice. At the radiotherapy departments attention has been paid more likely to the problems of dominant teletherapy treatments. But in the two last decades the usage of brachytherapy methods has gradually increased because .nature of this treatment well as the possibilities of operating facility have been completely changed: new radionuclides of high activity are introduced and sophisticate afterloading systems controlled by computers are used. Consequently also the nature of errors, which can occurred in the clinical practice, has been changing. To determine the potentially hazardous parts of procedure the so-called 'process tree', which follows the flow of entire treatment process, has been created for most frequent type of applications. Marking the location of errors on the process tree indicates where failures occurred and accumulation of marks along branches show weak points in the process. Analysed data provide useful information to prevent medical events in brachytherapy .The results strength the requirements given in Recommendations of SONS and revealed the need for its amendment. They call especially for systematic registration of the events. (authors)

  7. Investigations concerning the application of PDR-afterloading-therapy

    International Nuclear Information System (INIS)

    Pohlmann, S.; Brock, A.; Prager, W.; Friedrich, K.

    1995-01-01

    Introduction: Despite the gain in experiences concerning the PDR-afterloading technology there are still some important questions about its application: Questions: 1. Are the radiation reactions of PDR with Ir-192 and LDR with Co-60 nearly the same? 2. In which way the PDR-regimen has to be modified in case of tumor volume 3 , e.g. brachytherapy in the head and neck region? 3. Is it possible to interrupt the PDR-therapy during the night? Material and methods: We compared the radiation reactions of LDR-technique and two PDR-regimens by means of the guinea pig skin model (20 female animals) The following regimens are used: 1. continuos LDR-regimen 30 Gy in 60 hours 2. PDR-regimen 0,5 Gy hourly pulse length 10 minutes, 30 Gy in 60 hours 3. PDR-regimen with 9 hours night break 30 Gy/60 hours The isodose distribution patterns of the LDR-source (Co-60 source with an activity of 2 GBq) and the PDR-source (Ir-192 source with an activity of nearly 15 GBq) are the same. We implanted an interstitial applicator on the right hand side of the animal back with a Co-60 source and on the left hand side an interstitial applicator for a PDR-irradiation. The radiation reactions were controlled by the help of an evaluation table in which the criteria of radiation reaction - exsudation, hair growth and atrophy - were classified according to the degree of seriousness. The observation time is maximal 21 months. The degrees of seriousness are presented graphically in diagrams which we analysed by means of the cross-correlation-function. Results and conclusions: 1. Generally, it is possible to compare the radiation reactions of PDR irradiation and the classic continuos LDR brachytherapy with Co-60-sources. Calculations with the aid of the Monte-Carlo-method resulted in the fact that the gamma dose is the same in a distance of 2 mm from the source. 2. The activity of the source corresponds to the volume of tumor: the smaller the volume of the tumor the lower the dose rate (activity) of the

  8. Patterns of care for brachytherapy in Europe. Results in Spain.

    Science.gov (United States)

    López Torrecilla, J; Guedea, F; Heeren, G; Nissin, R; Ellison, T; Cottier, B

    2006-05-01

    In 2003 ESTRO began a project whose primary objective, was to make a map in the European area of infrastructures in technology and personnel for brachytherapy. A survey and a web site were elaborated. The survey was sent to the 76 Spanish Radiation Oncology departments in May 2003. By the end of 2003, 66 (86.8%) services had responded, 40 (71.4%) of which had brachytherapy. The services with brachytherapy treated 73.5% of the total patients, an average of 1,199 patients. The mean number of patients treated with brachytherapy by department was 135.5 and the number of applications was 265 annually. The average number of specialists was 7, 4 of them trained in brachytherapy. The average weekly work load of the radiation oncologists, physicists, and technicians was 22.6 h, 13.8 h and 21.0 h, respectively. The mean time dedicated to each patient by radiation oncologists, physicists and technicians was 9.2 h; 6.19 h; 7.2 h, respectively. The total number of afterloaders was 43 (22 HDR, 18 LDR, 3 PDR). The tumours most frequently treated with brachytherapy were gynaecological (56.24%), breast (14.2%) and prostate (11.7%). High dose rate was used in 47.46% of the patients and low dose rate in 47.24%. Between 1997 and 2002 there was an increase of 50.53% in patients treated with brachytherapy. The survey shows the brachytherapy resources and activity in Spain up to 2003. Increased use of brachytherapy in prostate tumours, prevalence of gynaecology brachytherapy and similar number of treatments with HDR and LDR are demonstrated in the Patterns of Care of Brachytherapy in Europe (PCBE) study in Spain.

  9. An analysis of personnel dose records which justifies the application of cost-benefit analysis techniques in the design of an afterloading facility and the use of controlled areas and systems of work within suite to control occupational exposure

    Energy Technology Data Exchange (ETDEWEB)

    Gifford, D; Kear, D [Bristol General Hospital (UK); Godden, T J [Bristol Radiotherapy and Oncology Centre (UK)

    1990-03-01

    The sealed source operational policies employed at the Bristol Radiotherapy and Oncology Centre are reviewed. On the basis of the cost-benefit analysis, it was decided not to provide additional shielding but rather to introduce administrative controls based on local rules which contained systems of work and the operational policies for the afterloading systems. After using the MDR afterloading systems for 2 years, a period in which there has also been a marked increase in interstitial brachytherapy, an analysis was made of the doses received by nursing staff over the past 8 years. This has shown that, in spite of higher dose rates in the corridor areas because of the use of an MDR system and the increase in interstitial techniques, the doses to ward nurses have been significantly reduced by encouraging staff to comply with the ALARA principle and the introduction of afterloading systems. (author).

  10. MRI-guided brachytherapy for cancer of the oesophagus

    International Nuclear Information System (INIS)

    Aydin, H.; Bachmann, G.; Lieven, H. von; Sens, M.

    1993-01-01

    A method of brachytherapy treatment planning using MRI is presented. In 13 patients with inoperable squamous cell cancer of the thoracic oesophagus an intraluminal afterloading boost with MRI assistance was performed. A new type of flexible catheter was filled with 1/100 diluted Gd-DTPA and introduced into the oesophagus before performing MRI in the sagittal, coronal and transverse planes. One sagittal or coronal picture which showed the catheter tip and the residual cancer was magnified to ''life size''. The position of the catheter was corrected if necessary and the treatment volume decided. The contrast medium was then aspirated out of the catheter and a thinner afterloading catheter pushed into the outer catheter. The patient was moved immediately to the afterloading room and received the first dose of boost irradiation. This method allows much more precise brachytherapy planning since it shows the cancer and the catheter together. It is superior to localising the cancer with a barium swallow or endoscopy because MRI visualises the whole extent of the residual cancer, which can then be covered with the necessary dose. (orig.)

  11. Combined transperineal radiofrequency (RF) interstitial hyperthermia and brachytherapy for localized prostate cancer (PC)

    International Nuclear Information System (INIS)

    Urakami, Shinji; Gonda, Nobuko; Kikuno, Nobuyuki

    2001-01-01

    Hyperthermia has been used effectively as a radiation sensitizer. Interstitial hyperthermoradiotherapy has been therefore utilized as a minimal invasive therapy in attempts to improve local tumor control for various cancers, but not for urological cancer. The purpose of this study was to investigate the safety and feasibility of transperineal hyperthermoradiotherapy for localized PC. Based on our basic study of hyperthermoradiotherapy, we devised the procedure of combined transperineal RF interstitial hyperthermia and brachytherapy for localized prostate cancer. Two patients with localized PC underwent transperineal RF interstitial hyperthermia combined with brachytherapy operation the 192-Ir remote after-loading system (RALS). Under transrectal ultrasound guidance, a total number of 12-18 stainless steel needles for 192-Ir RALS were implanted into the prostatic gland and seminal vesicles (SV) in an optimized pattern. Eight of the needles were used as electrodes for hyperthermia, and were electrically insultated using the vinyl catheter along the length of the subdermal fatty tissue to protect from overheating. Three other needles were utilized for continuous temperature mapping in the prostate. Rectal temperature was also monitored. Total radiation doses of 70 Gy to the prostate and SV were planned as a combination of brachytherapy (24 Gy/4 fraction) and external irradiation using a four-field box technique (46 Gy/23 fraction). Hyperthermic treatment (goal of 42 to 43 deg C for 60 minutes) was performed twice following the 1st and 4th brachytherapy at an interval of more than 48 hours for the recovery of cancer cells from thermotolerance. Both patients reached the treatment goal of all intraprostatic temperatures >43.0 deg C, which was considered favorable for hyperthermia, and the rectal temperatures of both patients remained <38 deg C during hyperthermia. In serial PSA measurements of both patients, serum PSA was less than 1.0 ng/ml within 3 months and has since

  12. A dosimetric intercomparison of brachytherapy facilities in Ireland, Scotland and the North of England

    International Nuclear Information System (INIS)

    Heeney, Conor; McClean, Brendan; Kelly, Colin

    2005-01-01

    Background and purpose: A dosimetric intercomparison of brachytherapy remote afterloading units in Ireland, Scotland and the North of England has been carried out involving 9 radiotherapy centres, and sampling 5 HDR and 6 LDR units. Materials and methods: Absolute calibrations have been performed in air on both HDR and LDR sources. The results are expressed in terms of a ratio of local to calibrated value. Frequency distributions were obtained for the multi-source LDR units by individually measuring each source. Using these distributions the effect of non-uniform source strength on the dose rate at Manchester point A was assessed for a typical clinical brachytherapy insertion for carcinoma of the cervix. Both frequency and dose rate distribution curves were modeled using normal statistics and characterised in terms of the mean (μ) and standard deviation (σ). Results: Evaluation of the HDR units indicated a mean ratio of 1.008 (±0.01) while for LDR the mean ratio was 0.997 (±0.02). The LDR frequency distributions demonstrated a variation of σ values extending from 1.4 to 3.0% of μ. It was shown that this non-uniformity in source strength introduced an uncertainty in the treatment planning process of between 0.8 and 1.8% when compared to the assumption of uniform source strength. Conclusions: The results of this intercomparison indicate dosimetric consistency between centres for both LDR and HDR units. The distribution of LDR source strengths were within expected limits and the resultant dose rate distributions were considered clinically acceptable

  13. Radiobiological considerations in gynaecological HDR and LDR brachytherapy

    International Nuclear Information System (INIS)

    Bauer, M.; Schulz-Wendtland, R.

    1989-01-01

    In brachytherapy the advantages of high dose rate over low dose rate afterloading therapy were obvious. Out-patient treatment becomes possible, the position of the sources is reproducible and can be observed during the treatment and the patients have to be immobilised for only a short time, giving less psychological stress and a decreased risk of thrombosis and embolism. When changing from LDR to HDR afterloading therapy we are not yet able to evaluate its biological impact. Radiobiological considerations and our experimental data, however, give us the following clinical consequences by using HDR brachytherapy: There is a need for about 15 fractions or more and each increase in dose rate requires higher fractioning. Due to the steep dose rate decline and the inhomogeneous dose distribution, multiple equivalence factors are necessary when fractioning is not sufficiently high. Correction factors to reduce the dose close to the source are low, with increasing distance from the source they increase. If HDR radiation therapy is used, the percutaneous dose in the pelvic wall region should be reduced. The reduction of the dose in HDR brachytherapy is a compromise to limit the side effects caused by the radiation. The drawback is a small therapeutic range and reduced therapeutic effectivity at the tumour. (orig.) [de

  14. Brachytherapy for carcinoma of the cervix: A Canadian survey of practice patterns in a changing era

    International Nuclear Information System (INIS)

    Pearce, Andrew; Craighead, Peter; Kay, Ian; Traptow, Laurel; Doll, Corinne

    2009-01-01

    Background and purpose: This survey aimed to document practices of Canadian radiation oncologists performing gynecologic brachytherapy for carcinoma of the cervix and to determine what the effect of the phasing-out of LDR after-loading systems from the commercial market is having on practice. Materials and methods: A 26-item questionnaire was developed to survey various aspects of brachytherapy practice to include: number of patients treated, prescription points/volume, dose and fractionation, timing, critical structure delineation, expected changes due to the phasing-out of support for low dose rate systems, and support for the development of national guidelines. A link to a web-based survey collection instrument was emailed to each radiation oncologist in Canada practicing gynecologic brachytherapy. Results: A 67% response rate was achieved in this web-based survey. Radiation oncologists currently using HDR brachytherapy are most commonly delivering 5 fractions of 6 Gy in addition to an EBRT dose of 45 Gy in 25 fractions. The median total dose equivalents to Point A was 82.9 Gy for both early and advanced disease. In response to the announcement by a major vendor that they would be phasing-out service for a popular LDR after-loader, 49% of Canadian radiation oncologists who practice brachytherapy for cervix cancer are changing to an HDR technique with a further 9% changing to a PDR technique. Eighty-six percent of respondents would support the development of national guidelines for cervix brachytherapy in Canada. Conclusions: Variation in practice exists in Canada in brachytherapy for cervix cancer. Many centers are in the process of phasing-out LDR techniques in response to the withdrawal of commercial support for these systems. Support for the development of Canadian national guidelines is high.

  15. New after-loading intrauterine packing device: ten years experience

    International Nuclear Information System (INIS)

    Sklaroff, D.M.; Baker, A.S.; Tasbas, M.

    1985-01-01

    A new variation of the uterine packing device for the treatment of endometrial carcinoma is described. It combines the advantages of the Holter technique with the after-loading method described by Simon. This device has been in use for more than 10 years and has been found most satisfactory

  16. In-phantom dosimetric measurements as quality control for brachytherapy. System check and constancy check; Messungen im Festkoerperphantom als Qualitaetskontrolle in der Brachytherapie. Systempruefung und Konstanzpruefung

    Energy Technology Data Exchange (ETDEWEB)

    Kollefrath, Michael; Bruggmoser, Gregor; Nanko, Norbert; Gainey, Mark [Universitaetsklinik Freiburg (Germany). Klinik fuer Strahlenheilkunde

    2015-09-01

    In brachytherapy dosimetric measurements are difficult due to the inherent dose-inhomogeneities. Typically in routine clinical practice only the nominal dose rate is determined for computer controlled afterloading systems. The region of interest lies close to the source when measuring the spatial dose distribution. In this region small errors in the positioning of the detector, and its finite size, lead to large measurement uncertainties that exacerbate the routine dosimetric control of the system in the clinic. The size of the measurement chamber, its energy dependence, and the directional dependence of the measurement apparatus are the factors which have a significant influence on dosimetry. Although ionisation chambers are relatively large, they are employed since similar chambers are commonly found on clinical brachytherapy units. The dose is determined using DIN 6800 [11] since DIN 6809-2 [12], which deals with dosimetry in brachytherapy, is antiquated and is currently in the process of revision. Further information regarding dosimetry for brachytherapy can be found in textbooks [1] and [2]. The measurements for this work were performed with a HDR (High-Dose-Rate) {sup 192}Ir source, type mHDR V2, and a Microselectron Afterloader V2 both from Nucletron/Elekta. In this work two dosimetric procedures are presented which, despite the aforemention difficulties, should assist in performing checks of the proper operation of the system. The first is a system check that measures the dose distribution along a line and is to be performed when first bringing the afterloader into operation, or after significant changes to the system. The other is a dosimetric constancy check, which with little effort can be performed monthly or weekly. It simultaneously verifies the positioning of the source at two positions, the functionality of the system clock and the automatic re-calculation of the source activity.

  17. Clinical experience with the MammoSite[reg] radiation therapy system for brachytherapy of breast cancer: Results from an international phase II trial

    International Nuclear Information System (INIS)

    Niehoff, Peter; Polgar, Csaba; Ostertag, Horst; Major, Tibor; Sulyok, Zoltan; Kimmig, Bernhard; Kovacs, Gyoergy

    2006-01-01

    Background and purpose: In a prospective multi-center phase II trial, we investigated the MammoSite[reg] Radiation Therapy System, a new device for delivering intracavitary brachytherapy following breast conserving surgery. The MammoSite[reg] is a dual lumen, closed ended catheter with a small, spherical inflatable balloon and a port for connecting a remote afterloader to the central lumen. We analyzed the surgical procedure and placement of the MammoSite[reg], treatment planning and radiation delivery complications and cosmesis, as well the comfort for the patients. Patients and methods: Between 2002 and 2004 a total of 32 patients (pts) were implanted using the MammoSite[reg]. The reference isodose was defined 1 cm from the balloon surface. We analyzed the post-implant anatomic position of the applicator and the geometric form of the balloon via ultrasound, CT and X-ray, related side effects, cosmetic outcome and patient quality of life. Results: Twenty-three out of 32 patients (72%) were eligible for MammoSite[reg] intracavitary brachytherapy. Twenty-eight percentage had to be excluded because of different reasons. Eleven patients were treated with primary brachytherapy with a total dose of 34 Gy (2x3.4 Gy) and 12 had a boost with a mean dose of 13.3 Gy (range: 7.5-15 Gy; 2x2.5 Gy) combined with EBRT and doses ranged between 46 and 50 Gy. In three cases a balloon rupture occurred. We observed two abscesses within 3 months of implantation and serious seroma development in 10 patients (39%). Skin related side effects were erythema in 21 patients (91%), hyperpigmentation in 13 patients (56%) and teleangiectasia in six patients (26%) after mean follow-up 20 months. Conclusions: The MammoSite[reg] Radiation Therapy System is a feasible treatment modality for intracavitary brachytherapy of breast cancer after breast conserving surgery. The advantage of the system is only one applicator is necessary for the delivery of a fractionated radiotherapy. In addition, patient

  18. Investigation of Anisotropy Caused by Cylinder Applicator on Dose Distribution around Cs-137 Brachytherapy Source using MCNP4C Code

    Directory of Open Access Journals (Sweden)

    Sedigheh Sina

    2011-06-01

    Full Text Available Introduction: Brachytherapy is a type of radiotherapy in which radioactive sources are used in proximity of tumors normally for treatment of malignancies in the head, prostate and cervix. Materials and Methods: The Cs-137 Selectron source is a low-dose-rate (LDR brachytherapy source used in a remote afterloading system for treatment of different cancers. This system uses active and inactive spherical sources of 2.5 mm diameter, which can be used in different configurations inside the applicator to obtain different dose distributions. In this study, first the dose distribution at different distances from the source was obtained around a single pellet inside the applicator in a water phantom using the MCNP4C Monte Carlo code. The simulations were then repeated for six active pellets in the applicator and for six point sources.  Results: The anisotropy of dose distribution due to the presence of the applicator was obtained by division of dose at each distance and angle to the dose at the same distance and angle of 90 degrees. According to the results, the doses decreased towards the applicator tips. For example, for points at the distances of 5 and 7 cm from the source and angle of 165 degrees, such discrepancies reached 5.8% and 5.1%, respectively.  By increasing the number of pellets to six, these values reached 30% for the angle of 5 degrees. Discussion and Conclusion: The results indicate that the presence of the applicator causes a significant dose decrease at the tip of the applicator compared with the dose in the transverse plane. However, the treatment planning systems consider an isotropic dose distribution around the source and this causes significant errors in treatment planning, which are not negligible, especially for a large number of sources inside the applicator.

  19. Reirradiation of nasopharyngeal carcinoma with intracavitary mold brachytherapy: an effective means of local salvage

    International Nuclear Information System (INIS)

    Law, Stephen C.K.; Lam, W.-K.; Ng, M.-F.; Au, S.-K.; Mak, W.-T.; Lau, W.-H.

    2002-01-01

    Purpose: To assess the role of intracavitary mold brachytherapy in salvaging local failure of nasopharyngeal carcinoma (NPC). Methods and Materials: The outcomes of 118 consecutive NPC patients with local failure treated with mold brachytherapy between 1989 and 1996 were retrospectively reviewed. Eleven patients received additional external radiotherapy. Results: All molds were tailor-made, and the whole procedure was performed under local anesthesia. Pharyngeal recess dissection was routinely performed to allow direct contact of the radioactive source with the pharyngeal recess, a common site of local failure. Initially, the molds were preloaded with 192 Ir wires, but since 1992, the sources have been manually afterloaded; the mold has also been redesigned for better conformity, ease of insertion, and radiation safety. Using brachytherapy alone, 50-55 Gy was given for recurrence in 4-7 days; for persistence, 40 Gy was administered. The overall complete remission rate was 97%. The rates of 5-year local control, relapse-free survival, disease-specific survival, overall survival, and major complication were 85%, 68.3%, 74.8%, 61.3%, and 46.9%, respectively. Major complications included nasopharyngeal necrosis with headache, necrosis of cervical vertebrae with atlantoaxial instability, temporal lobe necrosis, and palsy of the cranial nerves. The afterloaded mold was as effective as the preloaded version, but with fewer complications. Conclusions: Intracavitary mold brachytherapy was effective in salvaging NPC with early-stage local persistence or first recurrence

  20. High-dose-rate afterloading intracavitary irradiation and expandable metallic biliary endoprosthesis for malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, Hitoshi; Ohishi, Hajime; Yoshioka, Tetsuya [Nara Medical Univ., Kashihara (Japan); and others

    1989-04-01

    A double lumen catheter was developed as an applicator for the remote afterloading system (RALS) of {sup 60}Co for the intracavitary irradiation of an obstructed common bile duct due to gallbladder cancer in 1 case and by cholangiocarcinoma in 7 cases. This was followed by the biliary endoprosthesis with expandable metallic stents to maintain patency. The mean survival period after treatment was not long (14 weeks). However, removal of the external drainage tube was possible in 7 of the 8 cases, and none of the 8 cases showed dislodgement or deformity of the stent, or obstruction of the bile duct in the stent-inserted area. This combination effectively provided palliation, and has considerable potential for malignant biliary obstruction. (author).

  1. Procedures for brachytherapy sources lost in a radiotherapy department; Protocolo para fontes de braquiterapia extraviadas no ambiente hospitalar

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Adelaide de [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras

    1997-12-31

    Brachytherapy sources are easily lost in a Radiotherapy Department owing to unexpected behaviour of the patient and/or inattention of the people in charge of the sources. This work reports a protocol to be used when brachytherapy sources are lost and it was based on the search of three sealed sources of Cesium 137 with activity of 37 x 10{sup 7} Bq, removed by a patient from a conventional afterloading intra-uterine system (Henscke). (author) 5 refs., 3 figs.; e-mail: dalmeida at biomag.ffclrp.usp.br

  2. WE-F-BRD-01: HDR Brachytherapy II: Integrating Imaging with HDR

    Energy Technology Data Exchange (ETDEWEB)

    Craciunescu, O [Duke University Medical Center, Durham, NC (United States); Todor, D [Virginia Commonwealth University, Richmond, VA (United States); Leeuw, A de

    2014-06-15

    In recent years, with the advent of high/pulsed dose rate afterloading technology, advanced treatment planning systems, CT/MRI compatible applicators, and advanced imaging platforms, image-guided adaptive brachytherapy treatments (IGABT) have started to play an ever increasing role in modern radiation therapy. The most accurate way to approach IGABT treatment is to provide the infrastructure that combines in a single setting an appropriate imaging device, a treatment planning system, and a treatment unit. The Brachytherapy Suite is not a new concept, yet the modern suites are incorporating state-of-the-art imaging (MRI, CBCT equipped simulators, CT, and /or US) that require correct integration with each other and with the treatment planning and delivery systems. Arguably, an MRI-equipped Brachytherapy Suite is the ideal setup for real-time adaptive brachytherapy treatments. The main impediment to MRI-IGABT adoption is access to MRI scanners. Very few radiation oncology departments currently house MRI scanners, and even fewer in a dedicated Brachytherapy Suite. CBCT equipped simulators are increasingly offered by manufacturers as part of a Brachytherapy Suite installation. If optimized, images acquired can be used for treatment planning, or can be registered with other imaging modalities. This infrastructure is relevant for all forms of brachytherapy, especially those utilizing multi-fractionated courses of treatment such as prostate and cervix. Moreover, for prostate brachytherapy, US imaging systems can be part of the suite to allow for real-time HDR/LDR treatments. Learning Objectives: Understand the adaptive workflow of MR-based IGBT for cervical cancer. Familiarize with commissioning aspects of a CBCT equipped simulator with emphasis on brachytherapy applications Learn about the current status and future developments in US-based prostate brachytherapy.

  3. WE-F-BRD-01: HDR Brachytherapy II: Integrating Imaging with HDR

    International Nuclear Information System (INIS)

    Craciunescu, O; Todor, D; Leeuw, A de

    2014-01-01

    In recent years, with the advent of high/pulsed dose rate afterloading technology, advanced treatment planning systems, CT/MRI compatible applicators, and advanced imaging platforms, image-guided adaptive brachytherapy treatments (IGABT) have started to play an ever increasing role in modern radiation therapy. The most accurate way to approach IGABT treatment is to provide the infrastructure that combines in a single setting an appropriate imaging device, a treatment planning system, and a treatment unit. The Brachytherapy Suite is not a new concept, yet the modern suites are incorporating state-of-the-art imaging (MRI, CBCT equipped simulators, CT, and /or US) that require correct integration with each other and with the treatment planning and delivery systems. Arguably, an MRI-equipped Brachytherapy Suite is the ideal setup for real-time adaptive brachytherapy treatments. The main impediment to MRI-IGABT adoption is access to MRI scanners. Very few radiation oncology departments currently house MRI scanners, and even fewer in a dedicated Brachytherapy Suite. CBCT equipped simulators are increasingly offered by manufacturers as part of a Brachytherapy Suite installation. If optimized, images acquired can be used for treatment planning, or can be registered with other imaging modalities. This infrastructure is relevant for all forms of brachytherapy, especially those utilizing multi-fractionated courses of treatment such as prostate and cervix. Moreover, for prostate brachytherapy, US imaging systems can be part of the suite to allow for real-time HDR/LDR treatments. Learning Objectives: Understand the adaptive workflow of MR-based IGBT for cervical cancer. Familiarize with commissioning aspects of a CBCT equipped simulator with emphasis on brachytherapy applications Learn about the current status and future developments in US-based prostate brachytherapy

  4. Pulsed dose rate brachytherapy – is it the right way?

    Directory of Open Access Journals (Sweden)

    Janusz Skowronek

    2010-10-01

    Full Text Available Pulsed dose rate (PDR-BT treatment is a brachytherapy modality that combines physical advantages of high-doserate (HDR-BT technology (isodose optimization, radiation safety with the radiobiological advantages of low-dose-rate (LDR-BT brachytherapy. Pulsed brachytherapy consists of using stronger radiation source than for LDR-BT and producing series of short exposures of 10 to 30 minutes in every hour to approximately the same total dose in the sameoverall time as with the LDR-BT. Modern afterloading equipment offers certain advantages over interstitial or intracavitaryinsertion of separate needles, tubes, seeds or wires. Isodose volumes in tissues can be created flexibly by a combinationof careful placement of the catheter and the adjustment of the dwell times of the computerized stepping source.Automatic removal of the radiation sources into a shielded safe eliminates radiation exposures to staff and visitors.Radiation exposure is also eliminated to the staff who formerly loaded and unloaded multiplicity of radioactive sources into the catheters, ovoids, tubes etc. This review based on summarized clinical investigations, analyses the feasibility and the background to introduce this brachytherapy technique and chosen clinical applications of PDR-BT.

  5. Preliminary results of interstitial [sup 192]Ir brachytherapy for malignant gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Kengo; Nakagawa, Minoru; Higashi, Hisato [Okayama Univ. (Japan). School of Medicine; and others

    1992-09-01

    Twenty-six patients with recurrent or unremovable malignant gliomas were treated by interstitial brachytherapy with iridium-192 seeds. Stereotactic implantation of the afterloading catheters using the Brown-Roberts-Wells computed tomography (CT)-guided stereotactic system was performed in 24 patients and surgical CT, magnetic resonance imaging, and clinical examination. Tumor regression was seen in 17 patients 1-3 months after implantation. Tumor progression was seen in only three patients. After interstitial brachytherapy, the most commonly observed CT finding was central low density. Median survival time was 18 months after implantation. Autopsies in five patients revealed the delayed effects of radiation injury such as typical vascular changes, microcalcification, and coagulative necrosis in the implant area and tumor recurrence at the periphery. The results suggest that brachytherapy is not curative but prolonged the median survival time by 6 months. (author).

  6. Current status of brachytherapy in cancer treatment – short overview

    Directory of Open Access Journals (Sweden)

    Janusz Skowronek

    2017-12-01

    Full Text Available Cancer incidence and mortality depend on a number of factors, including age, socio-economic status and geographical location, and its prevalence is growing around the world. Most of cancer treatments include external beam radiotherapy or brachytherapy. Brachytherapy, a type of radiotherapy with energy from radionuclides inserted directly into the tumor, is increasingly used in cancer treatment. For cervical and skin cancers, it has become a standard therapy for more than 100 years as well as an important part of the treatment guidelines for other malignancies, including head and neck, skin, breast, and prostate cancers. Compared to external beam radiotherapy, brachytherapy has the potential to deliver an ablative radiation dose over a short period of time directly to the altered tissue area with the advantage of a rapid fall-off in dose, and consequently, sparing of adjacent organs. As a result, the patient is able to complete the treatment earlier, and the risks of occurrence of another cancer are lower than in conventional radiotherapy treatment. Brachytherapy has increased its use as a radical or palliative treatment, and become more advanced with the spread of pulsed-dose-rate and high-dose-rate afterloading machines; the use of new 3D/4D planning systems has additionally improved the quality of the treatment. The aim of the present study was to present short summaries of current studies on brachytherapy for the most frequently diagnosed tumors. Data presented in this manuscript should help especially young physicians or physicists to explore and introduce brachytherapy in cancer treatments.

  7. SU-F-T-28: Evaluation of BEBIG HDR Co-60 After-Loading System for Skin Cancer Treatment Using Conical Surface Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Safigholi, H; Soliman, A; Song, W Y [Department of Medical Physics, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, ON (Canada); Meigooni, A S [Department of Radiation Therapy, Comprehensive Cancer Center of Nevada, Las Vegas, NV (United States); Han, D [Departemt of Radiation Oncology, University of California San Francisco, San Francisco, CA (United States)

    2016-06-15

    Purpose: To evaluate the possibility of utilizing the BEBIG HDR 60Co remote after-loading system for malignant skin surface treatment using Monte Carlo (MC) simulation technique. Methods: First TG-43 parameters of BEBIG-Co-60 and Nucletron Ir-192-mHDR-V2 brachytherapy sources were simulated using MCNP6 code to benchmark the sources against the literature. Second a conical tungsten-alloy with 3-cm diameter of Planning-Target-Volume (PTV) at surface for use with a single stepping HDR source is designed. The HDR source is modeled parallel to treatment plane at the center of the conical applicator with a source surface distance (SSD) of 1.5-cm and a removable plastic end-cap with a 1-mm thickness. Third, MC calculated dose distributions from HDR Co-60 for conical surface applicator were compared with the simulated data using HDR Ir-192 source. The initial calculations were made with the same conical surface applicator (standard-applicator) dimensions as the ones used with the Ir-192 system. Fourth, the applicator wall-thickness for the Co-60 system was increased (doubled) to diminish leakage dose to levels received when using the Ir-192 system. With this geometry, percentage depth dose (PDD), and relative 2D-dose profiles in transverse/coronal planes were normalized at 3-mm prescription-depth evaluated along the central axis. Results: PDD for Ir-192 and Co-60 were similar with standard and thick-walled applicator. 2D-relative dose distribution of Co-60, inside the standard-conical-applicator, generated higher penumbra (7.6%). For thick-walled applicator, it created smaller penumbra (<4%) compared to Ir-192 source in the standard-conicalapplicator. Dose leakage outside of thick-walled applicator with Co-60 source was approximately equal (≤3%) with standard applicator using Ir-192 source. Conclusion: Skin cancer treatment with equal quality can be performed with Co-60 source and thick-walled conical applicators instead of Ir-192 with standard applicators. These conical

  8. Human reliability in high dose rate afterloading radiotherapy based on FMECA

    International Nuclear Information System (INIS)

    Deng Jun; Fan Yaohua; Yue Baorong; Wei Kedao; Ren Fuli

    2012-01-01

    Objective: To put forward reasonable and feasible recommendations against the procedure with relative high risk during the high dose rate (HDR) afterloading radiotherapy, so as to enhance its clinical application safety, through studying the human reliability in the process of carrying out the HDR afterloading radiotherapy. Methods: Basic data were collected by on-site investigation and process analysis as well as expert evaluation. Failure mode, effect and criticality analysis (FMECA) employed to study the human reliability in the execution of HDR afterloading radiotherapy. Results: The FMECA model of human reliability for HDR afterloading radiotherapy was established, through which 25 procedures with relative high risk index were found,accounting for 14.1% of total 177 procedures. Conclusions: FMECA method in human reliability study for HDR afterloading radiotherapy is feasible. The countermeasures are put forward to reduce the human error, so as to provide important basis for enhancing clinical application safety of HDR afterloading radiotherapy. (authors)

  9. The feasibility study and characterization of a two-dimensional diode array in “magic phantom” for high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Espinoza, A.; Beeksma, B.; Petasecca, M.; Fuduli, I.; Porumb, C.; Cutajar, D.; Lerch, M. L. F.; Rosenfeld, A. B.; Corde, S.; Jackson, M.

    2013-01-01

    Purpose: High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly 192 Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 μGy m 2 /h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the functionality of the remote afterloader. This paper describes the feasibility study of a QA system for HDR brachytherapy using a phantom based two-dimensional 11 × 11 epitaxial diode array, named “magic phantom.”Methods: The HDR brachytherapy treatment plan is translated to the phantom with two rows of 10 (20 in total) HDR source flexible catheters, arranged above and below the diode array “magic plate” (MP). Four-dimensional source tracking in each catheter is based upon a developed fast iterative algorithm, utilizing the response of the diodes in close proximity to the 192 Ir source, sampled at 100 ms intervals by a fast data acquisition (DAQ) system. Using a 192 Ir source in a solid water phantom, the angular response of the developed epitaxial diodes utilized in the MP and also the variation of the MP response as a function of the source-to-detector distance (SDD) were investigated. These response data are then used by an iterative algorithm for source dwelling position determination. A measurement of the average transit speed between dwell positions was performed using the diodes and a fast DAQ.Results: The angular response of the epitaxial diode showed a variation of 15% within 360°, with two flat regions above and below the detector face with less than 5% variation. For SDD distances of between 5 and 30 mm the relative response of

  10. Application of the Monte Carlo integration method in calculations of dose distributions in HDR-Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Baltas, D; Geramani, K N; Ioannidis, G T; Kolotas, C; Zamboglou, N [Strahlenklinik, Stadtische Kliniken Offenbach, Offenbach (Germany); Giannouli, S [Department of Electrical and Computer Engineering, National Technical University of Athens, Athens (Greece)

    1999-12-31

    Source anisotropy is a very important factor in brachytherapy quality assurance of high dose rate HDR Ir 192 afterloading stepping sources. If anisotropy is not taken into account then doses received by a brachytherapy patient in certain directions can be in error by a clinically significant amount. Experimental measurements of anisotropy are very labour intensive. We have shown that within acceptable limits of accuracy, Monte Carlo integration (MCI) of a modified Sievert integral (3D generalisation) can provide the necessary data within a much shorter time scale than can experiments. Hence MCI can be used for routine quality assurance schedules whenever a new design of HDR or PDR Ir 192 is used for brachytherapy afterloading. Our MCI calculation results are comparable with published experimental data and Monte Carlo simulation data for microSelectron and VariSource Ir 192 sources. We have shown not only that MCI offers advantages over alternative numerical integration methods, but also that treating filtration coefficients as radial distance-dependent functions improves Sievert integral accuracy at low energies. This paper also provides anisotropy data for three new Ir 192 sources, one for microSelectron-HDR and two for the microSelectron-PDR, for which data currently is not available. The information we have obtained in this study can be incorporated into clinical practice.

  11. Reconstruction of MRI/CT compatible ring and tandem applicators in CT or MRI images used for treatment planning in brachytherapy

    International Nuclear Information System (INIS)

    Surendran, N.; Kim, Hayeon; Beriwal, Sushil; Saiful Huq, M.

    2008-01-01

    Brachytherapy (BT) plays a crucial role in the management of invasive cervix cancer from stage I to IV. Intracavitary techniques are based on afterloading devices, with different types of applicators. CT and/or MRI compatible applicators allow a sectional image based approach with a better assessment of gross tumour volume (GTV) and definition and delineation of target volume (CTV) compared to traditional approaches. To evaluate reconstruction of MRI/CT compatible ring and tandem applicators in 3D CT or MRI images used for treatment planning in Brachytherapy

  12. Acceptance testing and commissioning of a new model HDR afterloader

    International Nuclear Information System (INIS)

    McDermott, Patrick N.; Somnay, Archana R.; Alecu, Rodica

    1996-01-01

    We have recently performed acceptance testing procedures and have commissioned a new model HDR afterloader, the Varian VariSource with ''Intelligent Drive.'' Our site was one of the first installations worldwide. It is our intent to describe our tests and the results of the tests particularly as they may differ from other afterloaders. The Ir-192 source is unique among afterloaders marketed in the US in that it is very slender (OD of source wire is 0.59 mm) and relatively long (two 0.5 cm sources for a total active length of 1.0 cm). A check of source homogeneity by autoradiograph as urged by the US Nuclear Regulatory Commission demonstrates no detectable source inhomogeneity. Reentrant well ionization chambers are calibrated in the US with a 3.5 mm long source at Accredited Dosimetry Calibration Laboratories. Therefore calibration needs to be considered with some care. Calibration of the first delivered source with a well ionization chamber indicated agreement with the manufacturer's stated activity to within 0.5%. Source positioning is checked with a device called a 'cam scale'. Tests have been carried out on this system and it has been found to accurately indicate source position to within ±0.5 mm. Timer accuracy has been found to be better than 0.1% for dwell times of several hundred seconds. The intelligent drive system and the small source diameter allow the source wire to negotiate paths with small radius of curvature. A series of tests have been made in which the source is forced to negotiate 'U' turns of decreasing radius of curvature. A 4.7 F, 100 cm long catheter was used for these tests and the 'U' turn was positioned at approximately 90 cm. Under these conditions, the VariSource was consistently able to traverse a 1.25 cm radius of curvature, which is better than the manufacturer's stated limit of 1.5 cm

  13. Intracavitary mould brachytherapy in malignant tumors of the maxilla

    International Nuclear Information System (INIS)

    Rosenblatt, Edward; Blumenfeld, Israel; Cederbaum, Martin; Kuten, Abraham

    1996-01-01

    Purpose: To integrate brachytherapy in the combined modality management of malignant tumors of the maxilla, as a means of increasing the radiotherapy dose to the tumor bed while avoiding high doses to the orbital contents. Materials and methods: Following a partial or total maxillectomy, a duplication of the interim surgical obturator was created using a wash of vinyl polysiloxane. This mould was used as a carrier for afterloading nylon catheters through which 192-Iridium seed-ribbons were inserted. Following brachytherapy, selected patients also received external beam irradiation. Results and discussion: After a median follow-up of 36 months, 9 out of 11 patients are alive and disease-free; 1 developed a local recurrence and another relapsed at another site in the oral cavity. Transient grade 1 - 2 mucositis at the implant site was observed in all patients. The review of computer isodose distributions showed that the average dose received by the homolateral eyeball was 10% (range 9,2 - 10.0) of the prescribed surface dose to the surgical cavity. Conclusions: Brachytherapy can be integrated in the management of patients with malignant tumors of the maxilla in the form of a custom-made intracavitary mould carrying 192-Iridium sources. We found this technique particularly useful in cases with close or positive surgical margins

  14. Survey of brachytherapy practice in France in 1995. Definitive results

    International Nuclear Information System (INIS)

    Peiffert, D.; Simon, J.M.; Baillet, F.

    1998-01-01

    A survey questionnaire was sent to the 189 French departments of radiation Oncology and 166 responded (88%). Ninety-nine departments declared treating patients by brachytherapy and 358 shielded rooms were available. In Low Dose Rate (LDR) 81 departments used Cesium sources (159 after-loaders, 1,060 sources); Iridium wires were used by 84 departments (673 meters used). Only six departments used other elements. Twenty-six departments were equipped with high dose rate after loaders (HDR) all of them also using LDR techniques for most of the patients. A total of 9,160 patients were treated: 7,868 with LDR and 1,292 with HDR. The common sites treated by LDR were utero-vagina (4,300), breast (1,415), head and neck (1,409), skin (610), anorectal (220) and urologic (70). HDR was used for vaginal cuff (628), bronchi (371), oesophagus (232). PDR just started (33 patients) for a feasibility trial. The rate of patients treated by brachytherapy is around 6-8% of the irradiated patients, but the indications vary is each department. The diffusion of the techniques, and new indications should increase the number of patients being treated by brachytherapy. (authors)

  15. High dose rate brachytherapy for the treatment of soft tissue sarcoma of the extremity

    International Nuclear Information System (INIS)

    Speight, J.L.; Streeter, O.E.; Chawla, S.; Menendez, L.E.

    1996-01-01

    Purpose: we examined the role of preoperative neoadjuvant chemoradiation and adjuvant high-dose rate brachytherapy on the management of prognostically unfavorable soft tissue sarcomas of the extremities. Our goal was to examine the effect of high dose rate interstitial brachytherapy (HDR IBT) on reducing the risk of local recurrence following limb-sparing resection, as well as shortening treatment duration. Materials and methods: eleven patients, ranging in age from 31 to 73 years old, with soft tissue sarcoma of the extremity were treated at USC/Norris Comprehensive Cancer Center during 1994 and 1995. All patients had biopsy proven soft tissue sarcoma, and all were suitable candidates for limb-sparing surgery. All lesions were greater than 5cm in size and were primarily high grade. Tumor histologies included malignant fibrous histiocytoma (45%), liposarcoma (18%) and leiomyosarcoma, synovial cell sarcoma and spindle cell sarcoma (36%). Sites of tumor origin were the lower extremity (55%), upper extremity (18%) and buttock (9%), 1 patient (9%) had lesions in both the upper and lower extremity. Patients received HDR IBT following combined chemotherapy and external beam irradiation (EBRT) and en bloc resection of the sarcoma. Neoadjuvant chemotherapy consisted of three to four cycles of either Ifosfamide/Mesna with or without Adriamycin, or Mesna, Adriamycin, Ifosfamide and Dacarbazine. One patient received Cis-platin in addition to Ifos/Adr. A minimum of two cycles of chemotherapy were administered prior to EBRT. Additional cycles of chemotherapy were completed concurrently with EBRT but prior to HDR IBT. Preoperative EBRT doses ranging from 40 to 59.4 Gy were given in daily fractions of 180 to 200cGy. Following en bloc resection, HDR IBT was administered using the Omnitron tm 2000 remote afterloading system. Doses ranging from 13 to 30 Gy were delivered to the surgical tumor bed at depths of 0.5mm to 0.75mm from the radioactive source. Results: median follow-up was

  16. Prostate cancer brachytherapy

    International Nuclear Information System (INIS)

    Abreu, Carlos Eduardo Vita; Silva, Joao L. F.; Srougi, Miguel; Nesrallah, Adriano

    1999-01-01

    The transperineal brachytherapy with 125 I/Pd 103 seed implantation guided by transurethral ultrasound must be presented as therapeutical option of low urinary morbidity in patients with localized prostate cancer. The combined clinical staging - including Gleason and initial PSA - must be encouraged, for definition of a group of low risk and indication of exclusive brachytherapy. Random prospective studies are necessary in order to define the best role of brachytherapy, surgery and external beam radiation therapy

  17. Prostate brachytherapy - discharge

    Science.gov (United States)

    Implant therapy - prostate cancer - discharge; Radioactive seed placement - discharge ... You had a procedure called brachytherapy to treat prostate cancer. Your treatment lasted 30 minutes or more, ...

  18. Re-evaluation of a radiation protection cost benefit analysis study in brachytherapy

    International Nuclear Information System (INIS)

    Broek, J.G. van den; Weatherburn, H.

    1994-01-01

    This study investigates changes in the NRPB advice concerning cost benefit analysis over the last 10 years by correcting all figures for inflation and applying them to a particular radiation protection example, a previously published case of the introduction of afterloading brachytherapy equipment at the Christie Hospital, Manchester. It has been shown that for this example NRPB advice at one time led to a large cost benefit, at another time led to a large cost deficit and later still it again gives a large cost benefit. Application of cost benefit analysis to decision making in radiation protection is therefore shown to be in need of further investigation and clarification. (author)

  19. A comprehensive study on HDR brachytherapy treatments of cervical cancers: using the first Co-60 BEBIG Multisource Unit in Bangladesh

    Directory of Open Access Journals (Sweden)

    Naheed Rukhsana

    2011-07-01

    Full Text Available Purpose: The report presents an extraordinary synthesis of customer acceptance procedures (CAP, quality assurance tests (QA in the treatment of cervical cancer patients, using the first Co-60 Multisource Unit® in Bangladesh. The QA and commissioning required measurements and emergency tests verifying the functional limits of parameters acceptable for the new HDR afterloader. Acceptable limits were: 1 the deviation between specified and measured source strength: ± 3%; 2 the positional accuracy and uniformity: ± 1 mm; 3 the temporal accuracy (i.e. timer error and linearity and end error: ± 1% or 30 sec.; 4 treatment planning system (digitizer and localization software: ± 3% or 1 mm; 5 the distance from line to first dwell position and all the others: 5 mm and 10 mm (± 1 mm. Material and methods: Till February 2011, 47 patients were treated with HDR with more than 140 insertions applied. Amongst them, 12 patients were in stage IIB and IIIB, 22 were postoperative (IA and IB while the remaining 13 patients were with unknown stage. All the cases with stage IIB and IIIB received concurrent chemo-radiation and brachytherapy. Postoperative patients received EBRT (50 Gy and HDR according to the institutional protocol. CT scans were completed before HDR-plus planning with a good reproducibility (± 2% and were documented in repeating the plan for the same set up of a patient. Absorbed dose (Gy to a point P, at a distance of “r” in centimeters from a source of the Reference Air Kerma Rate (RAKR has been utilized for the QA of the source, where source strength measurement was accomplished. Results: All methods and analysis applicable to the QA and commissioning of Co-60 have been investigated and systematically analyzed, measured and documented before the treatment of a patient. Studies and safety requirements of this HDR remote afterloader were carried out. Acceptance and the QA were imperative to justify functionality and dependability in

  20. A comprehensive study on HDR brachytherapy treatments of cervical cancers: using the first Co-60 BEBIG Multisource Unit in Bangladesh.

    Science.gov (United States)

    Malik, Sadiq R; Banu, Parvin A; Rukhsana, Naheed

    2011-06-01

    The report presents an extraordinary synthesis of customer acceptance procedures (CAP), quality assurance tests (QA) in the treatment of cervical cancer patients, using the first Co-60 Multisource Unit ® in Bangladesh. The QA and commissioning required measurements and emergency tests verifying the functional limits of parameters acceptable for the new HDR afterloader. Acceptable limits were: 1) the deviation between specified and measured source strength: ± 3%; 2) the positional accuracy and uniformity: ± 1 mm; 3) the temporal accuracy (i.e. timer error and linearity and end error): ± 1% or 30 sec.; 4) treatment planning system (digitizer and localization software): ± 3% or 1 mm; 5) the distance from line to first dwell position and all the others: 5 mm and 10 mm (± 1 mm). Till February 2011, 47 patients were treated with HDR with more than 140 insertions applied. Amongst them, 12 patients were in stage IIB and IIIB, 22 were postoperative (IA and IB) while the remaining 13 patients were with unknown stage. All the cases with stage IIB and IIIB received concurrent chemo-radiation and brachytherapy. Postoperative patients received EBRT (50 Gy and HDR) according to the institutional protocol. CT scans were completed before HDR-plus planning with a good reproducibility (± 2%) and were documented in repeating the plan for the same set up of a patient. Absorbed dose (Gy) to a point P, at a distance of "r" in centimeters from a source of the Reference Air Kerma Rate (RAKR) has been utilized for the QA of the source, where source strength measurement was accomplished. All methods and analysis applicable to the QA and commissioning of Co-60 have been investigated and systematically analyzed, measured and documented before the treatment of a patient. Studies and safety requirements of this HDR remote afterloader were carried out. Acceptance and the QA were imperative to justify functionality and dependability in delivering the treatment. Implications of these studies

  1. Interstitial brachytherapy in carcinoma of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Chaudhary, A.J.; Ghosh, S.; Bhalavat, R.L. [Tata Memorial Hospital, Mumbai (India). Dept. of Radiation Oncology; Kulkarni, J.N. [Tata Memorial Hospital, Mumbai (India). Dept. of Surgery; Sequeira, B.V.E. [Tata Memorial Hospital, Mumbai (India). Dept. of Medical Physics

    1999-01-01

    Aim: Keeping in line with the increasing emphasis on organ preservation, we at the Tata Memorial Hospital have evaluated the role of Ir-192 interstitial implant as regards local control, functional and cosmetic outcome in early as well as locally recurrent carcinoma of the distal penis. Patients and Methods: From October 1988 to December 1996, 23 patients with histopathologically proven cancer of the penis were treated with radical radiation therapy using Ir-192 temporary interstitial implant. Our patients were in the age group of 20 to 60 years. The primary lesions were T1 and 7, T2 in 7 and recurrent in 9 patients. Only 7 patients had palpable groin nodes at presentation, all of which were pathologically negative. The median dose of implant was 50 Gy (range 40 to 60 Gy), using the LDR afterloading system and the Paris system of implant rules for dosimetry. Follow-up ranged from 4 to 117 months (median 24 months). Results: At last follow-up 18 of the 23 patients remained locally controlled with implant alone. Three patients failed only locally, 2 locoregionally and 1 only at the groin. Of the 5 patients who failed locally, 4 were successfully salvaged with partial penectomy and remained controlled when last seen. Local control with implant alone at 8 years was 70% by life table analysis. The patients had excellent functional and cosmetic outcome. We did not record any case of skin or softtissue necrosis. Only 2 patients developed meatal stenosis, both of which were treated endoscopically. Conclusion: Our results lead us to interpret that interstitial brachytherapy with Ir-192 offers excellent local control rates with preservation of organ and function. Penectomy can be reserved as a means for effective salvage. (orig.) [Deutsch] Ziel: Das Prinzip des Organerhalts gewinnt in der Onkologie zunehmend an Bedeutung. Ziel dieser Untersuchung war es, die Rolle der interstitiellen Brachytherapie mit Ir-192 zur Behandlung des fruehen und rezidivierten Peniskarzinoms zu

  2. Advantages of high-dose rate (HDR) brachytherapy in treatment of prostate cancer

    Science.gov (United States)

    Molokov, A. A.; Vanina, E. A.; Tseluyko, S. S.

    2017-09-01

    One of the modern methods of preserving organs radiation treatment is brachytherapy. This article analyzes the results of prostate brachytherapy. These studies of the advantages of high dose brachytherapy lead to the conclusion that this method of radiation treatment for prostate cancer has a favorable advantage in comparison with remote sensing methods, and is competitive, preserving organs in comparison to surgical methods of treatment. The use of the method of polyfocal transperineal biopsy during the brachytherapy session provides information on the volumetric spread of prostate cancer and adjust the dosimetry plan taking into account the obtained data.

  3. Calibration of {sup 192}Ir high dose rate brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    Marechal, M H [Instituto de Radioprotecao e Dozimetria, Rio de Jainero (Brazil); Almeida, C.E. de [Laboratorio de Ciencias Radiologicas, UERL, Rio de Janeiro (Brazil); Sibata, C H [Roswell Park Cancer Inst., Buffalo, NY (United States)

    1996-08-01

    A method for calibration of high dose rate sources used in afterloading brachytherapy systems is described. The calibration for {sup 192}Ir is determined by interpolating {sup 60}Co gamma-rays and 250 kV x-rays calibration factors. All measurements were done using the same build up caps as described by Goetsch et al and recommended by AAPM. The attenuation correction factors were determined to be 0.9903, 0.9928 and 0.9993 for {sup 192}Ir, {sup 60}Co and 250 kV x-ray, respectively. A wall + cap thickness of 0.421 g.cm{sup -2} is recommended for all measurements to ensure electronic equilibrium for {sup 60}Co and {sup 192}Ir gamma-ray beams. A mathematical formalism is described for determination of (N{sub x}){sub Ir}. (author). 5 refs, 1 fig.

  4. Advancements in brachytherapy

    DEFF Research Database (Denmark)

    Tanderup, Kari; Ménard, Cynthia; Polgar, Csaba

    2017-01-01

    Brachytherapy is a radiotherapy modality associated with a highly focal dose distribution. Brachytherapy treats the cancer tissue from the inside, and the radiation does not travel through healthy tissue to reach the target as with external beam radiotherapy techniques. The nature of brachytherap...

  5. Effects of changed working methods on personnel doses at a I-131 and afterloading therapy ward

    International Nuclear Information System (INIS)

    Lange, D.; Wolf, G.; Georgi, P.; Bauer, M.

    1985-01-01

    The external load of the personnel from I-131 therapy can be kept small (almost 'neglectable') by appropriate behaviour without keeping patients 'under-lock and key'. The marked decrease in personnel doses is due to improved radiation protection for afterloading therapy (gynecological Ra-therapy, Cs-137-therapy) by technical equipment. This therapy is now possible but with the door of the application room closed; when the door is opened, the instruments automatically go back to their original position. From 1975 through 1982, there were remote control errors forcing the personnel to withdraw the instruments to the safe manually. Despite working regulations the personnel was able to go into the room without prior instrument withdrawal. The personnel doses so received were within the tolerance limits, however markedly above the inevitable values. Because of regular thyroid gland examination of the personnel there is proof for the fact that the radiation load of this organ from I-131 is probably smaller than 2% (6 mSv/a=600 mrem/a) of the annual limit value of 0.3 Sv (30 rem) which corresponds to 6 times the value of normal load. (orig./HP) [de

  6. Fractionated afterloading therapy in inoperable malignant tumours of the brain

    International Nuclear Information System (INIS)

    Sparenberg, A.

    1987-01-01

    With the advent of the method of afterloading the range of uses for fractionated interstitial brady-therapy could be broadened to include malignant cerebral tumours. The mean survival time of 33 female patients was calculated to be 8.3 months for the entire group and 11.3 months for cases not otherwise pretreated. Even though the age, tumour volume, target dose and Karnofsky index obviously tended to influence the survival time, such relationships could not be confirmed statistically. Using the method by Kaplan-Meier it was determined that 65% of the total study group were likely to survive beyond six months and 32% to survive for one year. A separate analysis of patients receiving no previous treatment showed these chances to be 75% and 44%, respectively. The advantages of this therapy are discussed on a comparative basis. (VHE) [de

  7. Evaluation of time, attendance of medical staff, and resources during interstitial brachytherapy for prostate cancer. DEGRO-QUIRO trial

    International Nuclear Information System (INIS)

    Tselis, N.; Zamboglou, N.; Maurer, U.; Popp, W.; Sack, H.

    2014-01-01

    The German Society of Radiation Oncology initiated a multicenter trial to evaluate core processes and subprocesses of radiotherapy by prospective evaluation of all important procedures in the most frequent malignancies treated by radiation therapy. The aim of this analysis was to assess the required resources for interstitial high-dose-rate (HDR) and low-dose-rate (LDR) prostate brachytherapy (BRT) based on actual time measurements regarding allocation of personnel and room occupation needed for specific procedures. Two radiotherapy centers (community hospital of Offenbach am Main and community hospital of Eschweiler) participated in this prospective study. Working time of the different occupational groups and room occupancies for the workflow of prostate BRT were recorded and methodically assessed during a 3-month period. For HDR and LDR BRT, a total of 560 and 92 measurements, respectively, were documented. The time needed for treatment preplanning was median 24 min for HDR (n=112 measurements) and 6 min for LDR BRT (n=21). Catheter implantation with intraoperative HDR real-time planning (n=112), postimplantation HDR treatment planning (n=112), and remotely controlled HDR afterloading irradiation (n=112) required median 25, 39, and 50 min, respectively. For LDR real-time planning (n=39) and LDR treatment postplanning (n=32), the assessed median duration was 91 and 11 min, respectively. Room occupancy and overall mean medical staff times were 194 and 910 min respectively, for HDR, and 113 and 371 min, respectively, for LDR BRT. In this prospective analysis, the resource requirements for the application of HDR and LDR BRT of prostate cancer were assessed methodically and are presented for first time. (orig.)

  8. Evaluation of time, attendance of medical staff, and resources during interstitial brachytherapy for prostate cancer. DEGRO-QUIRO trial

    Energy Technology Data Exchange (ETDEWEB)

    Tselis, N.; Zamboglou, N. [Sana Klinikum Offenbach, Department of Radiation Oncology, Offenbach am Main (Germany); Maurer, U. [St.-Antonius-Hospital, Strahlentherapie, Eschweiler (Germany); Popp, W. [Prime Networks AG, Basel (Switzerland); Sack, H. [University of Essen, Department of Radiation Oncology, Essen (Germany)

    2014-04-15

    The German Society of Radiation Oncology initiated a multicenter trial to evaluate core processes and subprocesses of radiotherapy by prospective evaluation of all important procedures in the most frequent malignancies treated by radiation therapy. The aim of this analysis was to assess the required resources for interstitial high-dose-rate (HDR) and low-dose-rate (LDR) prostate brachytherapy (BRT) based on actual time measurements regarding allocation of personnel and room occupation needed for specific procedures. Two radiotherapy centers (community hospital of Offenbach am Main and community hospital of Eschweiler) participated in this prospective study. Working time of the different occupational groups and room occupancies for the workflow of prostate BRT were recorded and methodically assessed during a 3-month period. For HDR and LDR BRT, a total of 560 and 92 measurements, respectively, were documented. The time needed for treatment preplanning was median 24 min for HDR (n=112 measurements) and 6 min for LDR BRT (n=21). Catheter implantation with intraoperative HDR real-time planning (n=112), postimplantation HDR treatment planning (n=112), and remotely controlled HDR afterloading irradiation (n=112) required median 25, 39, and 50 min, respectively. For LDR real-time planning (n=39) and LDR treatment postplanning (n=32), the assessed median duration was 91 and 11 min, respectively. Room occupancy and overall mean medical staff times were 194 and 910 min respectively, for HDR, and 113 and 371 min, respectively, for LDR BRT. In this prospective analysis, the resource requirements for the application of HDR and LDR BRT of prostate cancer were assessed methodically and are presented for first time. (orig.)

  9. Introduction of a hybrid treatment delivery system used for quality assurance in multi-catheter interstitial brachytherapy

    Science.gov (United States)

    Kallis, Karoline; Kreppner, Stephan; Lotter, Michael; Fietkau, Rainer; Strnad, Vratislav; Bert, Christoph

    2018-05-01

    Multi-catheter interstitial brachytherapy (iBT) is a treatment option for breast cancer patients after breast conserving surgery. Typically, only a few additional quality interventions after the first irradiation have been introduced to ensure the planned treatment delivery. Therefore, the purpose of this study is to show the possibilities of an electromagnetic tracking (EMT) system integrated into the afterloader for quality assurance (QA) in high-dose rate (HDR) iBT of patients with breast cancer. The hybrid afterloader system equipped with an electromagnetic sensor was used for all phantom and patient measurements. Phantom measurements were conducted to estimate the quality of different evaluation schemes. After a coherent point drift registration of the EMT traces to the reconstructed catheters based on computed tomograms the dwell positions (DP) were defined. Different fitting and interpolation methods were analyzed for the reconstruction of DPs. All estimated DPs were compared to the DPs defined in treatment planning. Until now, the implant geometry of 20 patients treated with HDR brachytherapy was acquired and explored. Regarding the reconstruction techniques, both fitting and interpolation were able to detect manually introduced shifts and swaps. Nonetheless, interpolation showed superior results (RMSE  =  1.27 mm), whereas fitting seemed to be more stable to distortion and motion. The EMT system proved to be beneficial for QA in brachytherapy and furthermore, clinical feasibility was proven.

  10. Radiation protection in brachytherapy

    International Nuclear Information System (INIS)

    Benitez, Manuel

    1996-02-01

    It covers technical procedures in medical applications for cancer treatment. Radiation protection principles in brachytherapy. Medical uses in therapy for Sr-90, Cs-137, Co-60, Ra-226, Ir-192, Au-198, Bi-214, Pb-214. (The author)

  11. Radioactive sources in brachytherapy:

    OpenAIRE

    Burger, Janez

    2003-01-01

    Background. In modern brachytherapy, a greast step forward was made in the 1960s in France with the introduction of new radioactive isotopes and new techniques. These innovations spread rapidly across Europe, though no single dosimetry standard had been set by then. In the new millennium, the advances in brachytherapy are further stimulated by the introduction of 3-D imaging techniques and the latest after loading irradiation equipment that use point sources. The international organiyation IC...

  12. Fricke gel-layer dosimetry in HDR brachytherapy

    International Nuclear Information System (INIS)

    Gambarini, G.; Negri, A.; Carrara, M.; Marchesini, R.

    2008-01-01

    Full text: In the last decade, technological improvements in radiotherapy have been significant and consequently the use and importance of radiotherapy in cancer treatment have increased greatly. In brachytherapy, new possibilities have been opened by the impressive progresses in 3D imaging, by the development of sophisticated techniques for modern afterloaders and by the constantly increasing speed and capacity of computers. However, these methodological improvements require corresponding improvements in the dosimetry methods, in order to ensure that the values calculated with computer treatment planning systems, adopted in the clinical praxis, agree with the delivered dose distributions. Fricke gel-layer dosimeters (FGLD) are under study by our group as a reliable alternative to films, semiconductors arrays or thermoluminescent dosimeters (TLDs). In the last years, we have significantly improved this technique by defining the FGLD best chemical composition, by optimizing the image acquisition assessment and by developing a dedicated software for image analysis. In this study, experimental measurements of planar dose distributions of a clinical 192 Ir source (Microselectron HDR, Nucletron) obtained by irradiating a series of piled-up FGL dosimeters in a tissue-equivalent phantom are presented. The obtained results were in accordance to TLD measurements and to treatment planning system (Plato, Nucletron) calculations. FGLD have proven to be a reliable tool to achieve HDR brachytherapy dose distribution measurements

  13. Stem signal suppression in fiber-coupled Al2O3:C dosimetry for 192Ir brachytherapy

    DEFF Research Database (Denmark)

    Kertzscher Schwencke, Gustavo Adolfo Vladimir; Andersen, Claus Erik; Edmund, J.M.

    2011-01-01

    was adapted for on-line in-vivo dosimetry using fiber-coupled carbon doped aluminum oxide (Al2O3:C). The technique involved a two-channel optical filtration of the radioluminescence (RL) emitted from a pre-irradiated Al2O3:C crystal with enhanced sensitivity. The system responded linearly in the absorbed dose......The stem signal, composed of fluorescence and Čerenkov light, becomes a significant source of uncertainty in fiber-coupled afterloaded brachytherapy dosimetry when the source dwells near the fiber cable but far from the detector. A stem suppression technique originally developed for scintillators...

  14. Emergency rescue in accidents with HDR afterloading units

    International Nuclear Information System (INIS)

    Kaulich, T.W.; Nuesslin, F.; Becker, G.; Lamprecht, U.; Bamberg, M.

    1999-01-01

    Problem: HDR brachyradiotherapy has minimized the exposure to radiation of the personnel working in this field. Nonetheless there are periodically reported troubles with afterloading units concerning the retraction of sources that require immediate action for the limitation of possible damage. Legal Principles according to the German Regulation Concerning Protection against Radiation (Strahlenschutzverordnung=StrlSchV): If in afterloading brachyradiotherapy the radiation source remains extended through malfunction we deal with an emergency according to the StrlSchV. The rescue personnel should be chosen in accordance with Paragraph 50 StrlSchV. Organization of the Rescue of the Patient: The quickest possible rescue of a patient in an emergency demands an unequivocal definition of responsibilities. Our recommendations in this instance: The physicist is responsible for the organization of the emergency rescue. The radiation oncologist in charge informs himself about the necessary emergency measures before starting the treatment and carries out the emergency rescue. If the physicist diagnoses a failure in the retraction of the source he tries to remove the failure. If he doesn't succeed in retracting the source the radiation oncologist carries out the rescue of the patient. The organizational structure of the clinic allowing, the emergency physician should invariably be the physician who placed the applicator. In the emergency rescue the radiation oncologist should be protected by a lead barrier and use manipulators. Dose Assessment in Personnel and Patient: The radiation exposure of the rescue personnel is calculated from the photon-equivalence dose H x with the help of the dose-rate constant of 192 Ir. According to the same procedure there can be evaluated the local radiation exposure of the patient concerned. Conclusions: Generally speaking, all considerations regarding the topic of emergency rescue should always start out from a worst-case scenario. Of all the

  15. A comparison between tandem and ovoids and interstitial gynecologic template brachytherapy dosimetry using a hypothetical computer model

    International Nuclear Information System (INIS)

    Hsu, I-Chow J.; Speight, Joycelyn; Hai, Jenny; Vigneault, Eric; Phillips, Theodore; Pouliot, Jean

    2002-01-01

    coverage of the region lateral to the cervix. Smaller volumes of the vagina and uterine fundus received the full dose from the interstitial implant. The cumulative dose-volume histograms revealed larger high-dose regions within the treatment volume for the intracavitary system. The volumes receiving ≥180% of the prescription dose were 31 cc and 17 cc for the intracavitary system and interstitial system, respectively. The isodose lines showed that most of this difference results from the high-dose region around the tandem. The percentage dose-volume histograms showed that a larger percentage of cervix received a higher dose in the intracavitary system. Fifty-two percent of the target volume received 200% or higher of the prescription dose with tandem and ovoids, compared with only 20% with the template system. Analysis of dose points outside of the 100% isodose lines showed a slightly more rapid dose drop-off with the interstitial system compared to the intracavitary system. Point doses at 20, 25, and 30 mm from the tandem in the interstitial system were 100%, 69%, and 51% of prescribed dose, and from the intracavitary system were 101%, 76%, and 58%, respectively. Conclusions: Our dosimetric analysis revealed a better coverage in the parametrial regions, but underdosage of the central cervical region, for the interstitial system. On the other hand, because of the increased distance of source to dose point, there is a more rapid dose drop-off outside the treated volume with the interstitial system, which has the potential to improve tissue sparing. Based on this analysis, we caution against using a radiotherapy system with a homogenous central dose distribution when treating cervical cancer with an intact uterus. We recommend differential loading of the implant catheters with the majority of dose delivered from the tandem when using an interstitial GYN template with remote afterloader

  16. Homogeneous Ir-192 afterloading-flab-irradiation of plane surfaces

    International Nuclear Information System (INIS)

    Bratengeier, K.; Krieger, T.

    2002-01-01

    Homogeneous irradiation of plane targets bt Ir-192 afterloading flabs made by a parallel series of linear applicators can be time-consuming even with modern planning systems. The aim of the present study was to develop an algorithm that supplies homogeneous dose distributions in an arbitrary given plane in parallel to the equipped plane of a flab. The edge and corner positions of the flab are of particular importance. The identity of the dose in the optimisation distance above the flab centre, corners, and middle of the flab edges, leads to a strict relation of the respective dwell weights. Formulas can be derived that allow the calculation of the dwell times. The dimensioning of the flab can be rapidly adapted to new conditions. A comparison with the results of Nucletron PLATO-BPS for applicator-applicator distances and step sizes of 1 cm at optimisation distances of 10, 20, 30, and 40 mm and various flab sizes (3 x 3, 9 x 9, and 15 x 15 cm 2 ) shows the following results: The standard deviation of the proposed algorithm is sometimes slightly higher than the results of the commercial planning system, whereas the underdosage at the flab edges is usually smaller. The effort for planning and preparation of the irradiation, for example using a Nucletron HDR, is below 5 minutes - a considerable reduction of planning time. (orig.) [de

  17. A multicenter study to quantify systematic variations and associated uncertainties in source positioning with commonly used HDR afterloaders and ring applicators for the treatment of cervical carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Awunor, O., E-mail: onuora.awunor@stees.nhs.uk [The Medical Physics Department, The James Cook University Hospital, Marton Road, Middlesbrough TS4 3BW, England (United Kingdom); Berger, D. [Department of Radiotherapy, General Hospital of Vienna, Vienna A-1090 (Austria); Kirisits, C. [Department of Radiotherapy, Comprehensive Cancer Center, Medical University of Vienna, Vienna A-1090 (Austria)

    2015-08-15

    Purpose: The reconstruction of radiation source position in the treatment planning system is a key part of the applicator reconstruction process in high dose rate (HDR) brachytherapy treatment of cervical carcinomas. The steep dose gradients, of as much as 12%/mm, associated with typical cervix treatments emphasize the importance of accurate and precise determination of source positions. However, a variety of methodologies with a range in associated measurement uncertainties, of up to ±2.5 mm, are currently employed by various centers to do this. In addition, a recent pilot study by Awunor et al. [“Direct reconstruction and associated uncertainties of {sup 192}Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of HDR brachytherapy cervix patients,” Phys. Med. Biol. 58, 3207–3225 (2013)] reported source positional differences of up to 2.6 mm between ring sets of the same type and geometry. This suggests a need for a comprehensive study to assess and quantify systematic source position variations between commonly used ring applicators and HDR afterloaders across multiple centers. Methods: Eighty-six rings from 20 European brachytherapy centers were audited in the form of a postal audit with each center collecting the data independently. The data were collected by setting up the rings using a bespoke jig and irradiating gafchromic films at predetermined dwell positions using four afterloader types, MicroSelectron, Flexitron, GammaMed, and MultiSource, from three manufacturers, Nucletron, Varian, and Eckert & Ziegler BEBIG. Five different ring types in six sizes (Ø25–Ø35 mm) and two angles (45° and 60°) were used. Coordinates of irradiated positions relative to the ring center were determined and collated, and source position differences quantified by ring type, size, and angle. Results: The mean expanded measurement uncertainty (k = 2) along the direction of source travel was ±1.4 mm. The standard deviation

  18. Impact of afterload on the assessment of severity of aortic stenosis.

    Science.gov (United States)

    Chang, Sung-A; Kim, Hyung-Kwan; Sohn, Dae-Won

    2012-06-01

    Aortic stenosis (AS) is increasingly diagnosed in current aging society. Echocardiography is the most important tool in the assessment of AS and its severity. However, load-dependency of Doppler measurement could affect the accuracy of AS severity assessment. We tried to evaluate the impact of afterload on the assessment of AS severity by modification of afterload using pneumatic compression (Pcom). Forty patients diagnosed as moderate or severe AS [effective orifice area of aortic valve (EOA(AV)) by continuity equation of < 1.5 cm(2)] were consecutively enrolled. Patients with severely uncontrolled hypertension, severe left ventricular (LV) dysfunction, and other significant valve disease were excluded. Comprehensive echocardiography was performed at baseline to assess AS severity. Then, pneumatic compression of the lower extremities by 100 mmHg was applied to increase LV afterload. After 3 minutes, echocardiography was repeated to assess AS severity. Mean blood pressure was significantly increased under Pcom (p < 0.001), while heart rate remained unchanged. Peak aortic valve velocity (V(max)) was slightly, but significantly decreased under Pcom (p = 0.03). However, Doppler velocity index and EOA(AV) by continuity equation were not affected by Pcom. AS severity assessment by echocardiography was not dependent on the change of LV afterload imposed by Pcom. AV V(max) was slightly decreased with LV afterload increment, but these changes were too small to alter treatment plan of AS patients. EOA(AV) and Doppler velocity index are more stable parameters for AS severity assessment.

  19. Estimation of Filling and Afterload Conditions by Pump Intrinsic Parameters in a Pulsatile Total Artificial Heart.

    Science.gov (United States)

    Cuenca-Navalon, Elena; Laumen, Marco; Finocchiaro, Thomas; Steinseifer, Ulrich

    2016-07-01

    A physiological control algorithm is being developed to ensure an optimal physiological interaction between the ReinHeart total artificial heart (TAH) and the circulatory system. A key factor for that is the long-term, accurate determination of the hemodynamic state of the cardiovascular system. This study presents a method to determine estimation models for predicting hemodynamic parameters (pump chamber filling and afterload) from both left and right cardiovascular circulations. The estimation models are based on linear regression models that correlate filling and afterload values with pump intrinsic parameters derived from measured values of motor current and piston position. Predictions for filling lie in average within 5% from actual values, predictions for systemic afterload (AoPmean , AoPsys ) and mean pulmonary afterload (PAPmean ) lie in average within 9% from actual values. Predictions for systolic pulmonary afterload (PAPsys ) present an average deviation of 14%. The estimation models show satisfactory prediction and confidence intervals and are thus suitable to estimate hemodynamic parameters. This method and derived estimation models are a valuable alternative to implanted sensors and are an essential step for the development of a physiological control algorithm for a fully implantable TAH. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Postoperative irradiation of endometrial cancer by iridium afterloading technique

    International Nuclear Information System (INIS)

    Kucera, H.; Weghaupt, K.

    1988-01-01

    From 1981 to 1986 708 patients were operated and postoperativly treated by total hysterectomy, bilateral salpingo-oophorectomy and postoperative vaginal irradiation with high-dose-afterloading (iridium 192). A percutaneous irradiation (cobalt 60) was done in stage I cases only when myometrial infiltration was deep. Highly differentiated tumors with infiltration of the first and second thirth of the myometrium were treated by vaginal irradiation alone. Poorly differentiated tumors with infiltration of the second and third thirth of the myometrium were treated by vaginal and percutaneous irradiation. A group of 125 cases with good prognosis and with postoperative vaginal irradiation alone had the same five-year-survival of 83% as a group of 152 cases with bad prognosis treated by vaginal and percutaneous irrradiation. This result shows clearly the importance of additional irradiation of the pelvis in cases with bad prognosis factors. The incidence of radiation side effect in all 708 cases was: cystitis 4.6%, proctitis 5.2%, vaginal or rectal ulcera 1.4% and fistulas 0.2%. Cases with vaginal irradiation alone and with the optimal intravaginal fraction dose of 700 cGy (twice) had the lowest level of side effects: cystitis 3.8% proctitis 2.1%, vaginal necrosis 0.7%, no further severe complications. None of the patients with postoperative vaginal irradiation alone had a vaginal recurrence. The incidence of recurrences in 708 patients was 1.6%. All recurrence cases in stage I (0.7%) had bad prognosis factors and were treated with vaginal and percutaneous irradiation. (orig./MG) [de

  1. Palliation of recurrent esophageal cancer after definitive radiotherapy with intraluminal brachytherapy. A preliminary report

    International Nuclear Information System (INIS)

    Chen, Shang-Wen; Shiau, An-Cheng; Liang, Ji-An; Yang, Shih-Neng; Lin, Fang-Jen

    2004-01-01

    The objective was to assess the feasibility, toxicity, and efficacy of palliative intraluminal brachytherapy (ILBT) for recurrent esophageal cancer after definitive radiotherapy. From January 2000 to December 2002, 10 consecutive patients with recurrent esophageal cancer after definitive radiotherapy completed allocated ILBT, were enrolled into the analysis. All patients presented with a World Health Organization (WHO) dysphagia score III or more (III: 7; IV: 3). The ILBT was delivered with a special assembled applicator composed of three layers of plastic tubes, inserted transorally. The active treatment length of ILBT was defined as the site of recurrent esophageal tumor plus 1 cm each from the proximal and distal margins. The ILBT was performed by high-dose-rate iridium-192 remote after-loading technique. The ILBT consisted of 2 to 4 fractions of 3 Gy at 1-week intervals. The prescribed dose was specified at a 1 cm depth from the mid-dwell position and the dosimetry was calculated using computer-based software. Patients were followed up monthly and assessed for relief of dysphagia and development of complications. All patients completed the allocated ILBT schedule. Eight patients died (2 from distant metastasis; 3 from respiratory failure by tumor invasion; 2 from aspiration pneumonia; 1 from chemotherapy-induced sepsis). The median survival of the 10 patients was 5 months (range 2 to 32), and the estimated 1-year actuarial survival was 24%. Time to recurrence of more than 3 months was the only prognostic factor for longer survival (p=0.01). When the response of ILBT was assessed one month after treatment, eight patients achieved improvement of dysphagia, while two patients got worse. The median dysphagia progression-free interval (DPFI) of the 8 responders was 3 months (range 2 to 7). The predictive parameter for good ILBT response was an initial dysphagia score (p=0.01). Only one patient developed tracheo-esophageal fistula 3 months after ILBT. Fractionated

  2. Geometrical Sparing Factors for the Rectum and Bladder in the Prediction of Grade 2 and Higher Complications After High-Dose-Rate Brachytherapy for Cervical Cancer

    International Nuclear Information System (INIS)

    Chen, S.-W.; Liang, J.-A.; Hung, Y.-C.; Yeh, L.-S.; Chang, W.-C.; Yang, S.-N.; Lin, F.-J.

    2009-01-01

    Purpose: This study aimed to assess the predictive values of geometrical sparing factors for the rectum and bladder in high-dose-rate intracavitary brachytherapy (HDRICB) for Grade 2 and higher late sequelae in patients with cervical cancer. Methods: A total of 392 patients were enrolled in this study. They were treated with external beam radiotherapy to the pelvis, after which HDRICB was performed using Ir-192 remote after-loading at 1-week intervals for three or four sessions. The geometrical sparing factor (GSF) was defined as the average of the ratios between the reference doses and the Point A dose. Results: A total of 46 patients (11.7%) had Grade 2 or higher late rectal complications (36 Grade 2, 9 Grade 3, and 1 Grade 4). In all, 32 patients (8.2%) had Grade 2 or higher late bladder complications (14 Grade 2, 16 Grade 3, and 2 Grade 4). Multivariate analysis demonstrated a high risk of rectal sequelae in patients who developed bladder complications (p = 0.0004, hazard ratio 3.54) and had a rectal GSF greater than 0.7 (p = 0.01, hazard ratio 1.99). The high risk factors for bladder complications were development of rectal complications (p = 0.0004, hazard ratio 3.74), concurrent chemotherapy (p = 0.0001, relative risk 3.94), and a bladder GSF greater than 0.9 (p = 0.01, hazard ratio, 2.53). Conclusion: This study demonstrates the predictive value of GSFs in HDRICB for cervical cancer. Patients with rectal GSFs greater than 0.7 or bladder GSFs greater than 0.9 are at risk for Grade 2 and higher late sequelae.

  3. Dosimetric evaluation of rectum and bladder using image-based CT planning and orthogonal radiographs with ICRU 38 recommendations in intracavitary brachytherapy

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2008-01-01

    Full Text Available The purpose is to compare CT-based dosimetry with International Commission on Radiation Units and Measurements (ICRU 38 bladder and rectum reference points in patients of carcinoma of uterine cervix treated with intracavitary brachytherapy (ICA. Twenty-two consecutive patients were evaluated. Orthogonal radiographs and CT images were acquired and transferred to PLATO planning system. Bladder and rectal reference points were identified according to ICRU 38 recommendations. Dosimetry was carried out based on Manchester system. Patient treatment was done using 192 Iridium high dose rate (HDR remote after-loading machine based on the conventional radiograph-based dosimetry. ICRU rectal and bladder point doses from the radiograph plans were compared with D 2 , dose received by 2 cm 3 of the organ receiving maximum dose from CT plan. V 2 , volume of organ receiving dose more than the ICRU reference point, was evaluated. The mean (±standard deviation volume of rectum and bladder was 60 (±28 cm 3 and 138 (±41 cm 3 respectively. The mean reference volume in radiograph and CT plan was 105 (±7 cm 3 and 107 (±7 cm 3 respectively. It was found that 6 (±4 cm3 of rectum and 16 (±10 cm 3 of bladder received dose more than the prescription dose. V2 of rectum and bladder was 7 (±1.7 cm 3 and 20.8 (±6 cm 3 respectively. Mean D 2 of rectum and bladder was found to be 1.11 (±0.2 and 1.56 (±0.6 times the mean ICRU reference points respectively. This dosimteric study suggests that comparison of orthogonal X-ray-based and CT-based HDR ICA planning is feasible. ICRU rectal point dose correlates well with maximum rectal dose, while ICRU bladder point underestimates the maximum bladder dose.

  4. Geometrical sparing factors for the rectum and bladder in the prediction of grade 2 and higher complications after high-dose-rate brachytherapy for cervical cancer.

    Science.gov (United States)

    Chen, Shang-Wen; Liang, Ji-An; Hung, Yao-Ching; Yeh, Lian-Shung; Chang, Wei-Chun; Yang, Shih-Neng; Lin, Fang-Jen

    2009-12-01

    This study aimed to assess the predictive values of geometrical sparing factors for the rectum and bladder in high-dose-rate intracavitary brachytherapy (HDRICB) for Grade 2 and higher late sequelae in patients with cervical cancer. A total of 392 patients were enrolled in this study. They were treated with external beam radiotherapy to the pelvis, after which HDRICB was performed using Ir-192 remote after-loading at 1-week intervals for three or four sessions. The geometrical sparing factor (GSF) was defined as the average of the ratios between the reference doses and the Point A dose. A total of 46 patients (11.7%) had Grade 2 or higher late rectal complications (36 Grade 2, 9 Grade 3, and 1 Grade 4). In all, 32 patients (8.2%) had Grade 2 or higher late bladder complications (14 Grade 2, 16 Grade 3, and 2 Grade 4). Multivariate analysis demonstrated a high risk of rectal sequelae in patients who developed bladder complications (p = 0.0004, hazard ratio 3.54) and had a rectal GSF greater than 0.7 (p = 0.01, hazard ratio 1.99). The high risk factors for bladder complications were development of rectal complications (p = 0.0004, hazard ratio 3.74), concurrent chemotherapy (p = 0.0001, relative risk 3.94), and a bladder GSF greater than 0.9 (p = 0.01, hazard ratio, 2.53). This study demonstrates the predictive value of GSFs in HDRICB for cervical cancer. Patients with rectal GSFs greater than 0.7 or bladder GSFs greater than 0.9 are at risk for Grade 2 and higher late sequelae.

  5. Brachytherapy for oral cancer

    International Nuclear Information System (INIS)

    Monzen, Yoshio; Ajimu, Akira; Morikawa, Minoru; Hayashi, Nobuyuki; Yoshida, Shintarou; Ashizawa, Kazuto; Hayashi, Kuniaki; Ikenaga, Kouji; Sakamoto, Ichirou.

    1988-01-01

    13 cases with oral cancer were treated using brachytherapy at the Department of Radiology, Nagasaki University Hospital from September 1985 to February 1988. Among 11 cases of tongue cancer, T1 and T2 cases were well controlled by radiation therapy using 226 Ra needles. Cancer of oral floor and buccal mucosa were controlled by the use of 192 Au grains. (author)

  6. [Brachytherapy of brainstem tumors].

    Science.gov (United States)

    Julow, Jenö; Viola, Arpád; Major, Tibor; Valálik, István; Sági, Sarolta; Mangel, László; Kovács, Rita Beáta; Repa, Imre; Bajzik, Gábor; Németh, György

    2004-01-20

    The optimal therapy of brain stem tumours of different histopathology determines the expected length of survival. Authors report 125Iodine interstitial irradiation of brain stem tumours with stereotactic brachytherapy. Two patients having brain stem tumours were suffering from glioma or from metastases of a carcinoma. In Case 1 the tumour volume was 1.98 cm3 at the time of planning interstitial irradiation. The control MRI examination performed at 42 months post-op showed a postirradiation cyst size of 5.73 cm3 indicating 65.5% shrinkage. In Case 2 the shrinkage was more apparent as the tumour volume measured on the control MRI at 8 months post-op was only 0.16 cm3 indicating 97.4% shrinkage of the 6.05 cm3 target volume at the time of brachytherapy with the metastasis practically disappearing. Quick access to histopathological results of the stereotactic intraoperative biopsy made it possible to carry out the 125Iodine stereotactic brachytherapy immediately after the biopsy, resulting in less inconvenience for patients of a second possible intervention. The control MRI scans show significant shrinkage of tumours in both patients. The procedure can be performed as a biopsy. The CT and image fusion guided 125Iodine stereotactic brachytherapy can be well planned dosimetrically and is surgically precise.

  7. First experiences with super fractionated skin irradiations using large afterloading molds

    International Nuclear Information System (INIS)

    Fritz, Peter; Hensley, Frank W.; Berns, Christiane; Schraube, Peter; Wannenmacher, Michael

    1996-01-01

    Purpose: Radiotherapy of cutaneous metastases of breast cancer requires large radiation fields and high doses. This report examines the effectiveness and sequelae of super fractionated irradiation of cutaneous metastases of breast cancer with afterloading molds on preirradiated and nonirradiated skin. Methods and Materials: A flexible reusable skin mold was developed for use with a pulsed (PDR) after loader. An array of 18 parallel catheters was sewn between two foam rubber slabs 5 mm in thickness to provide a defined constant distance to the skin. By selection of appropriate dwell positions, arbitrarily shaped skin areas can be irradiated up to a maximal field size of 17 x 23.5 cm 2 . Irradiations are performed with a nominal 37 GBq 192 Ir stepping source in pulses of 1 Gy/h at the skin surface. The dose distribution is geometrically optimized. The 80 and 50% dose levels lie 5 and 27 mm below the skin surface. Sixteen patients suffering from metastases at the thoracic wall were treated with 18 fields (78-798 cm 2 ) and total doses of 40-50 Gy applying two PDR split courses with a pause of 4-6 weeks. Eleven of the fields had been previously irradiated with external beam therapy to doses of 50-60 Gy at 7-22 months in advance. Results: For preirradiated fields (n = 10) the results were as follows: follow-up 4.5-28.5 months (median 17); local control (LC): 8 of 10; acute skin reactions: Grade 2 (moist desquamation) 2 of 10; intermediate/late skin reactions after minimum follow-up of 3 months: Grade 1 (atrophy/pigmentation): 2 of 10, Grade 2-3a (minimal/marked telangiectasia): 7 of 10, Grade 4 (ulcer): 1 of 10; recurrencies: 2 of 10. For newly irradiated fields (n = 7) results were: follow-up: 2-20 months (median 5); LC: 6 of 7; acute reactions: Grade 1:4 of 7, Grade 2:3 of 7; intermediate/late skin reactions after minimum follow-up of 3 months (n = 5): Grade 2-3a: 2 of 5; recurrencies: 0 of 7. Local control could be achieved in 82% of the mold fields. Geometric

  8. Outcome of treatment of upper third vaginal recurrences of cervical and endometrial carcinomas with interstitial brachytherapy

    International Nuclear Information System (INIS)

    Charra, C.; Roy, P.; Coquard, R.; Romestaing, P.; Ardiet, J.M.; Gerard, J.P.

    1998-01-01

    Purpose: To describe an original brachytherapy technique using a dedicated intravaginal template for the treatment of vaginal vault recurrences and to evaluate the results of such a treatment. Methods and Materials: Between 1978 and 1993, 78 patients with isolated recurrence of cervical or endometrial carcinoma located in the vaginal vault have been treated in Lyon. Initial treatment was surgery alone in 49 cases and irradiation with surgery in 37 cases. Treatment of the vaginal recurrence was performed with interstitial Iridium 192 brachytherapy combined with pelvic external beam radiation therapy in 34 patients. The tumor was implanted with a dedicated intravaginal plastic template. Six parallel metallic needles were implanted in the vaginal vault and afterloaded with Iridium 192 wires of 4 to 6 cm long. The mucosa of the upper half of the vagina received the same dose as the one encompassing the tumor on the 85% isodose of the Paris system. Results: At 5 years the local control rate was 70% and the overall survival rate 56%. Grade 3 complications occurred in 10% of the cases and only in patients who had received irradiation during the initial treatment of the primary tumor. Conclusions: This brachytherapy technique makes it possible to perform Iridium 192 implants in a difficult situation with a favorable long-term control rate and an acceptable rate of complications

  9. Brachytherapy in the conservative treatment of soft tissue sarcomas extending to neurovascular structures: an analysis of 38 cases

    International Nuclear Information System (INIS)

    Thomas, L.; Delannes, M.; Stoeckle, E.; Martel, P.; Pigneux, J.; Daly-Schveitzer, N.; Bui, B.N.; Chevreau, C.; Kantor, G.

    1996-01-01

    To evaluate the tolerance of neurovascular structures to brachytherapy, a retrospective review of our series was undertaken. Between May 1986 and January 1994, 85 patients with soft tissue sarcomas underwent conservative surgery and low-dose rate interstitial irradiation. Thirty-eight patients had tumors extending to neurovascular structures. Brachytherapy was part of initial treatment in 30 patients and was done in 7 cases for recurrent sarcomas. Afterloading catethers for brachytherapy were inserted intraoperatively and placed direct upon or under the neurovascular structures in the tumor bed. A mean dose of 20 Gy was delivered to the target volume. Thirty patients received 45 to 50 Gy of postoperative external irradiation. With a median follow-up of 39 months, the 3-year actuarial survival was 82.9%, the 3-year disease-free survival was 71.9% and the 3-year actuarial local control was 91%. The 3-year actuarial incidence of distant metastase was 28%. Acute side effects occurred in 12 patients requiring conservative surgical procedures in 6 cases. Significant late toxicity occurred in 8 patients : 2 lymphoedemas interfering with normal activity, 1 partial artery stenosis, 5 peripheral neuropathy (2 grade 2, 3 grade 3). Late toxicity has led to significant impairment of mobility in 4 patients. Limb preservation was achieved in every patient, no amputation was required. We conclude that integration of brachytherapy in the conservative treatment of soft tissue sarcomas extending to neurovascular structures can provide excellent local control with an acceptable level of toxicity

  10. Studies on 192Ir afterloading irradiation of the canine prostate with special consideration of thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Reuter, M.

    1986-01-01

    A method for high dose rate afterloading irradiation of the prostate with iridium 192 was developed. The isodoses of the urethra and rectum, which were measured by means of thermoluminescent dosimetry, showed deviations from the doses pre-calculated by computer (BRACHY), because this calculation is based on an anatomically ideal condition. (MBC) [de

  11. Construction and use of an applicator of the afterloading type for treatment of the uterine cervix

    International Nuclear Information System (INIS)

    Miola, U.J.; Vizeu, D.M.; Moura, A.M.S.; Petito, J.W.

    The construction of an afterloading type applicator for treatment of cancer of the uterine cervix is described. The technique of intercavitary treatment of cancer of the uterine cervix used in the Osvaldo Cruz Institute of Radiotherapy (Brazil) is also discribed [pt

  12. A new after-loading intrauterine packing device: ten years experience.

    Science.gov (United States)

    Sklaroff, D M; Baker, A S; Tasbas, M

    1985-12-01

    A new variation of the uterine packing device for the treatment of endometrial carcinoma is described. It combines the advantages of the Holter technique with the after-loading method described by Simon. This device has been in use for more than 10 years and has been found most satisfactory.

  13. Glass microspheres for brachytherapy

    International Nuclear Information System (INIS)

    Prado, Miguel O.; Prastalo, Simon; Blaumann, Herman; Longhino, Juan M.; Repetto Llamazares, A.H.V.

    2007-01-01

    We developed the capacity to produce glass microspheres containing in their structure one or more radioactive isotopes useful for brachytherapy. We studied the various facts related with their production: (Rare earth) alumino silicate glass making, glass characterization, microspheres production, nuclear activation through (n,γ) nuclear reactions, mechanical characterization before and after irradiation. Corrosion tests in simulated human plasma and mechanical properties characterization were done before and after irradiation. (author) [es

  14. Computed tomography in brachytherapy

    International Nuclear Information System (INIS)

    Mansfield, C.M.; Lee, K.R.; Dwyer, S.; Zellmer, D.; Cook, P.

    1983-01-01

    CT scanning adds to the ability to evaluate brachytherapy techniques. It provides an additional method in the assessment of patients who are candidates for or who are being treated by brachytherapy. The CT scan can give information regarding the position of the sources and their relation to the tumor and normal structures with greater ease than do orthogonal views. This makes it possible to accurately calculate areas of high or low dose. Potential areas of overdose can be recognized, thereby decreasing the chances of postbrachytherapy complications. CT scanning can be used at various levels of complexity in dosimetry evaluation. Adequate brachytherapy dosimetry information is obtainable from CT slices through one or more levels of the implanted volume. In some instances it is possible to obtain additional information by reconstructing the scans in other planes, e.g., coronal or sagittal. Three-dimensional viewing of the implant is desirable, but it should be pointed out that this approach is time-consuming and beyond the capabilities of most institutions at present. It will be necessary to continue work on three-dimensional treatment planning to make it readily available

  15. What minimum number of fractions is required with high dose-rate remote afterloading; and reply

    International Nuclear Information System (INIS)

    Orton, C.G.

    1987-01-01

    The author presents 'a more rigorous application of the linear quadratic model for protracted radiotherapy than Dale (1985)' and demonstrates that considerably fewer than 17 fractions are needed, a conclusion particularly relevant to treatment of cancer of the cervix. Dale's reply is based on the tenet that Orton has misquoted the use of the damage repair constants. (UK)

  16. Implementation of a High-Dose-Rate Brachytherapy Program for Carcinoma of the Cervix in Senegal: A Pragmatic Model for the Developing World

    International Nuclear Information System (INIS)

    Einck, John P.; Hudson, Alana; Shulman, Adam C.; Yashar, Catheryn M.; Dieng, Mamadou M.; Diagne, Magatte; Gueye, Latifatou; Gningue, Fama; Gaye, Pape M.; Fisher, Brandon J.; Mundt, Arno J.; Brown, Derek W.

    2014-01-01

    West Africa has one of the highest incidence rates of carcinoma of the cervix in the world. The vast majority of women do not have access to screening or disease treatment, leading to presentation at advanced stages and to high mortality rates. Compounding this problem is the lack of radiation treatment facilities in Senegal and many other parts of the African continent. Senegal, a country of 13 million people, had a single 60 Co teletherapy unit before our involvement and no brachytherapy capabilities. Radiating Hope, a nonprofit organization whose mission is to provide radiation therapy equipment to countries in the developing world, provided a high-dose-rate afterloading unit to the cancer center for curative cervical cancer treatment. Here we describe the implementation of high-dose-rate brachytherapy in Senegal requiring a nonstandard fractionation schedule and a novel treatment planning approach as a possible blueprint to providing this technology to other developing countries

  17. Implementation of a High-Dose-Rate Brachytherapy Program for Carcinoma of the Cervix in Senegal: A Pragmatic Model for the Developing World

    Energy Technology Data Exchange (ETDEWEB)

    Einck, John P., E-mail: jeinck@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Hudson, Alana [Department of Oncology, Tom Baker Cancer Centre, University of Calgary, Calgary, Alberta (Canada); Shulman, Adam C. [Overlook Medical Center, Summit, New Jersey (United States); Yashar, Catheryn M. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Dieng, Mamadou M.; Diagne, Magatte; Gueye, Latifatou; Gningue, Fama; Gaye, Pape M. [Départemént de Radiothérapie, Institut Joliot-Curie, Hôpital Aristide Le Dantec, Dakar (Senegal); Fisher, Brandon J. [GammaWest Cancer Services, Salt Lake City, Utah (United States); Mundt, Arno J. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Brown, Derek W. [Department of Oncology, Tom Baker Cancer Centre, University of Calgary, Calgary, Alberta (Canada)

    2014-07-01

    West Africa has one of the highest incidence rates of carcinoma of the cervix in the world. The vast majority of women do not have access to screening or disease treatment, leading to presentation at advanced stages and to high mortality rates. Compounding this problem is the lack of radiation treatment facilities in Senegal and many other parts of the African continent. Senegal, a country of 13 million people, had a single {sup 60}Co teletherapy unit before our involvement and no brachytherapy capabilities. Radiating Hope, a nonprofit organization whose mission is to provide radiation therapy equipment to countries in the developing world, provided a high-dose-rate afterloading unit to the cancer center for curative cervical cancer treatment. Here we describe the implementation of high-dose-rate brachytherapy in Senegal requiring a nonstandard fractionation schedule and a novel treatment planning approach as a possible blueprint to providing this technology to other developing countries.

  18. Assessment of right ventricular afterload in mitral valve diseases with radionuclide angiography

    International Nuclear Information System (INIS)

    Shimizu, Mitsuharu; Nakagawa, Tomio; Kohno, Yoshihiro; Kuroda, Masahiro; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao; Senoh, Yoshimasa; Teramoto, Shigeru

    1991-01-01

    Right ventricular function at rest and during exercise was studied in 33 patients with mitral valve disease by equilibrium gated radionuclide angiography using 99m Tc in vivo labeled red blood cells. Radionuclide measurements of right ventricular ejection fraction (RVEF) were correlated with mean pulmonary arterial pressure (mPAP). RVEF decreased significantly with exercise. There was no significant correlation between RVEF at rest and mPAP. However, mPAP showed significant negative correlation with RVEF during exercise and with the changes of RVEF from rest to exercise. It is concluded that RVEF during exercise in mitral valve disease is affected by right ventricular afterload, and the measurements of RVEF at rest and during exercise by equilibrium gated radionuclide angiography is useful to assess right ventricular afterload. (author)

  19. Intra coronary brachytherapy

    International Nuclear Information System (INIS)

    Ghofourian, H.; Ghahremani, A.; Oliaie, A.; Taghizadeh Asl, M.

    2002-01-01

    Despite the initial promise of vasculopathy intervention restenosis- a consequence of the (normal) would healing process-has emerged as a major problem. Angiographic restenosis has been reported in 40-60% of patients after successful P TCA. The basic mechanism of restenosis, (acute recoil, negative remodeling and neo intimal hyperplasia), are only partially counteracted by endovascular prosthetic devices (s tents). The rate of in-s tent restenosis, which is primarily caused by neo intimal hyperplasia due to the (micro) trauma of the arterial wall by the s tent struts, has been reduced to 18-32%. Ionizing (beta or gamma) radiations has been established as a potent treatment for malignant disorders. In recent years, there has also been increasing interest among clinicians in the management of benign lesions with radiation. Over the past several years, there has been a growing body of evidence that endovascular brachytherapy has a major impact on the biology of the restenosis. It must be underlined that understanding the biology and pathophysiology of restenosis and assessing various treatment options should preferably be a team effort, with the three g races b eing interventional cardiologist, nuclear oncologist, and industrial partners. The vast amount of data in over 20000 patients from a wide range of randomized controlled trials, has shown that brachytherapy is the only effective treatment for in-s tent restenosis. We are learning more and more about how to improve brachytherapy. While the new coated s tents that we heard about today is fascinating and extremely promising, brachytherapy still has a very important place in difficult patients, such as those with total occlusions, osti al lesions, left main lesions, multivessel disease and diabetes. Regarding to above mentioned tips, we (a research team work, in the Nuclear Research Center Of the Atomic Energy Organization Of Iran), focused on synthesis and preparation of radioactive materials for use in I c-B T. We

  20. Contractility-afterload mismatch in patients with protein-losing enteropathy after the Fontan operation.

    Science.gov (United States)

    Ozawa, Hideto; Ueno, Takayoshi; Iwai, Shigemitsu; Kawata, Hiroaki; Nishigaki, Kyouichi; Kishimoto, Hidefumi; Sawa, Yoshiki

    2014-10-01

    This study aimed to clarify the relationship between onset of protein-losing enteropathy (PLE) and Fontan circulation, with special reference to the development of contractility-afterload mismatch. The PLE group comprised 9 patients who experienced PLE after undergoing the Fontan operation, and the control group consisted of 32 patients had did not experienced PLE more than 10 years after the Fontan operation. The study compared the pre- and postoperative values of arterial elastance (Ea), end-systolic elastance (Ees), and contractility-afterload mismatch (Ea/Ees). Furthermore, the variations in the values were examined during the preoperative, postoperative, and midterm postoperative periods in seven PLE patients who underwent cardiac catheterization at the onset of PLE and during the pre- and postintervention periods in three PLE patients who underwent surgical intervention to improve the Fontan circulation after the onset of PLE. Comparison of the values obtained before and after Fontan operations showed that the Ea values increased significantly in the PLE group. However, the pre- and postoperative Ees values did not differ in the two groups. During the postoperative period, Ea/Ees increased significantly, and the Ea and Ea/Ees values increased continuously until the onset of PLE in the PLE group. In the patients who underwent surgical intervention to improve the Fontan circulation after the onset of PLE, the Ea/Ees decreased significantly, and the serum albumin levels improved after the intervention. Contractility-afterload mismatch, mainly caused by the increase in the afterload of the systemic ventricle, may have an important role in the development of PLE after the Fontan operation.

  1. Development of brachytherapy medium doserate

    International Nuclear Information System (INIS)

    Atang Susila; Ari Satmoko; Ahmad Rifai; Kristiyanti

    2010-01-01

    Brachytherapy has proven to be an effective treatment for different types of cancers and it become a common treatment modality in most radiotherapy clinics. PRPN has had experience in development of Low Dose Rate Brachytherapy for cervix cancer treatment. However the treatment process using LDR device needs 5 hours in time that the patient feel uncomfort. Therefore PRPN develops Medium Dose Rate Brachytherapy with radiation activity not more than 5 Currie. The project is divided into two stages. Purchasing of TPS software and TDS design are held in 2010, and the construction will be in 2011. (author)

  2. Frequency of afterload homocysteinemia in normal population of Southern Iran: a pilot study.

    Science.gov (United States)

    Akbari, A; Dehbozorgian, J; Afrasibi, A R; Gafari, H; Gerdabi, J; Karimi, M

    2010-04-01

    The objectives of the present pilot study were to investigate the effect of an oral methionine load on plasma homocysteine in healthy subjects southern Iran. We studied 50 peoples (10 men, 40 women, median age 27.5, range 20-37) referred to screening center for marriage since different part of southern Iran. Methionine (0.1 g kg(-1) b.wt.) was immediately administrated orally in 200 mL of orange juice and a second blood was obtained 4 h later. Plasma level of homocysteine was carried out by high performance liquid chromatography and flumetric detection. A homocysteine level above 15 mmol L(-1) was considered high. The mean fasting and afterload homocysteine were 15.28 and 31.29 micromol L(-1), respectively. Fasting hyperhomocysteinemia (>15 micromol L(-1)) was detected in 12% of male and 8% in female which significantly higher in men than women (p homocysteine levels (> 31 micromol L(-1)) was detected in 16% of male and 14%in female which higher in men than women. Notably 80% of participants had normal total homocystein concentration (homocystein levels (p = 0.000), in 8% of those normal homocystein level, methionine afterload homocystein levels became abnormal. In conclusion, based on results, we recommend the methionine afterload homocystein levels in high risk cases with normal fasting level in order to unmissed some cases with normal basal homocystein level.

  3. Gynecological brachytherapy - from low-dose-rate to high-tech. Gynaekologische Brachytherapie - von Low-dose-rate zu High-tech

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, T. (Abt. Strahlenthgerapie, Klinik und Poliklinik fuer Radiologie, Medizinische Akademie ' Carl Gustav Carus' , Dresden (Germany)); Christen, N. (Abt. Strahlenthgerapie, Klinik und Poliklinik fuer Radiologie, Medizinische Akademie ' Carl Gustav Carus' , Dresden (Germany)); Alheit, H.D. (Abt. Strahlenthgerapie, Klinik und Poliklinik fuer Radiologie, Medizinische Akademie ' Carl Gustav Carus' , Dresden (Germany))

    1993-03-01

    The transition from low-dose-rate (LDR) brachytherapy to high-dose-rate (HDR) afterloading treatment is in progress in most centres of radiation therapy. First reports of studies comparing HDR and LDR treatment in cervix cancer demonstrate nearly equal local control. In our own investigations on 319 patients with primary irradiated carcinoma of the cervix (125 HDR/194 LDR) we found the following control rates: Stage FIGO I 95.4%/82.9% (HDR versus LDR), stage FIGO II 71.4%/73.7%, stage FIGO III 57.9%/38.5%. The results are not significant. The side effects - scored after EORT/RTOG criteria - showed no significant differences between both therapies for serious radiogenic late effects on intestine, bladder and vagina. The study and findings from the literature confirm the advantage of the HDR-procedure for patient and radiooncologist and for radiation protection showing at least the same results as in the LDR-area. As for radiobiolgical point of view it is important to consider that the use of fractionation in the HDR-treatment is essential for the sparing of normal tissues and therefore a greater number of small fractionation doses in the brachytherapy should be desirable too. On the other hand the rules, which are true for fractionated percutaneous irradiation therapy (overall treatment time as short as possible to avoid reppopulation of tumor cells) should be taken into consideration in combined brachy-teletherapy regime in gynecologic tumors. The first step in this direction may be accelerated regime with a daily application of both treatment procedures. The central blocking of the brachytherapy region from the whole percutaneous treatment target volume should be critically reflected, especially in the case of advanced tumors. (orig.)

  4. Computerized dosimetric system for studying radiation fields of afterloading apparatus

    International Nuclear Information System (INIS)

    Andryushin, O.S.; Gorshkov, M.I.

    1988-01-01

    Works on designing a computerized dosimetric scanner (CODOS) for studying radiation fields of remote therapeutic apparatus, providing dosimetric data input from semiconductor transducers and ionization chambers directly into the computer memory were carried out. The basic problems were to provide reproducibility and accuracy of the initial dosimetric data, formation of the data bank on LUEhV-15M1 accelerator bremsstrahlung and electron radiation fields. An extra problem was to provide isodose curves for manual scheduling of radiotherapy. The 15 VUMS-28-025 complex based on Elektronika-60 computer was chosen as a host computer, photodiodes were used as a semiconductor detector, the 70108 rod chamber and VA-J-18 dosemeters were used as an ionization chamber. The results of studies with the CODOS system have been shown that it meets the dosimetric requirements for therapeutic apparatus

  5. Brachytherapy in childhood rhabdomyosarcoma treatment

    International Nuclear Information System (INIS)

    Novaes, Paulo Eduardo Ribeiro dos Santos

    1995-01-01

    A retrospective study of 21 children with rhabdomyosarcoma treated by brachytherapy to the primary site of the tumor at the Radiotherapy Department of the A.C.Camargo Hospital between january/1980 to june/1993 was undertaken. The main objectives were to comprove the utility of brachytherapy in childhood rhabdomyosarcoma, to evaluate the local control and survival, in association with chemotherapy, to analyze the late effects of the treatment and to determinate the preferential technique to each clinical situation. All patients received brachytherapy to the tumor site. The radioactive isotopes employed were Gold 198 , Cesium 137 and Iridium 192 . The brachytherapy techniques depended on the tumor site, period of treatment, availability of the radioactive material and stage of the disease. Patients treated exclusively by brachytherapy received 40 Gy to 60 Gy. When brachytherapy was associated with external radiotherapy the dose ranged from 20 Gy to 40 Gy. Local control was achieved in 18 of 20 patients (90%). The global survival and local control survival rates were 61.9% (13/21 patients) and 72,2% (13/18 patients) respectively. (author)

  6. American brachytherapy society (ABS) guidelines for brachytherapy of esophageal cancer

    International Nuclear Information System (INIS)

    Nag, Subir; Gaspar, Laurie; Herskovic, Arnold; Mantravadi, Prasad; Speiser, Burton

    1996-01-01

    Introduction: There is wide variation in the indications, techniques, treatment regimens and dosimetry being used to treat cancer of the esophagus and no guidelines exist for optimal therapy. Methods: The Clinical Research Committee of the ABS met to formulate consensus guidelines for brachytherapy in esophageal cancer. Results: Good candidates for brachytherapy include patients with unifocal disease, with thoracic tumor 10 cm primary regional lymph adenopathy or tumor located in the gastro-esophageal junction or cervical esophagus. Contraindications include tracheo-esophageal fistula or stenosis that cannot be by-passed. The esophageal or nasogastric tube inserted should have a diameter of 6-10 mm whenever possible. If 5FU-based chemotherapy and 50 Gy external beam (EBRT) are used, it is suggested that the low dose rate brachytherapy (LDR) dose be 20 Gy at 0.4-1 Gy/hr, prescribed at 1 cm from the source. If high dose rate (HDR) is used, the dose recommended is 10 Gy in 2 weekly fractions of 5 Gy each, given after EBRT. Chemotherapy is not usually given concurrently with brachytherapy, and when it is, the brachytherapy dose is reduced. The length of esophagus treated by brachytherapy includes the post-EBRT involved area and a 1-2 cm margin proximally and distally. Supportive care, given during EBRT includes an antifungal agent (e.g., diflucan) and carafate. Gradual dilatation of the esophagus is required post-treatment for esophageal strictures. Conclusion: Guidelines were developed for brachytherapy in esophageal cancer. As more clinical data becomes available, these guidelines will be updated by the ABS

  7. Specification of brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    1984-10-01

    BCRU recommends that the following specification of gamma-ray brachytherapy sources be adopted. Unless otherwise stated, the output of a cylindrical source should be specified in air kerma rate at a point in free space at a distance of 1 m from the source on the radial plane of symmetry, i.e. the plane bisecting the active length and perpendicular to the cylindrical axis of the source. For a wire source the output should be specified for a 1 cm length. For any other construction of source, the point at which the output is specified should be stated. It is also recommended that the units in which the air kerma rate is expressed should be micrograys per hour (..mu..Gy/h).

  8. Pulsed dose rate and fractionated high dose rate brachytherapy: choice of brachytherapy schedules to replace low dose rate treatments

    International Nuclear Information System (INIS)

    Visser, Andries G.; Aardweg, Gerard J.M.J. van den; Levendag, Peter C.

    1996-01-01

    Purpose: Pulsed dose rate (PDR) brachytherapy is a new type of afterloading brachytherapy (BT) in which a continuous low dose rate (LDR) treatment is simulated by a series of 'pulses,' i.e., fractions of short duration (less than 0.5 h) with intervals between fractions of 1 to a few hours. At the Dr. Daniel den Hoed Cancer Center, the term 'PDR brachytherapy' is used for treatment schedules with a large number of fractions (at least four per day), while the term 'fractionated high dose rate (HDR) brachytherapy' is used for treatment schedules with just one or two brachytherapy fractions per day. Both treatments can be applied as alternatives for LDR BT. This article deals with the choice between PDR and fractionated HDR schedules and proposes possible fractionation schedules. Methods and Materials: To calculate HDR and PDR fractionation schedules with the intention of being equivalent to LDR BT, the linear-quadratic (LQ) model has been used in an incomplete repair formulation as given by Brenner and Hall, and by Thames. In contrast to earlier applications of this model, both the total physical dose and the overall time were not kept identical for LDR and HDR/PDR schedules. A range of possible PDR treatment schedules is presented, both for booster applications (in combination with external radiotherapy (ERT) and for BT applications as a single treatment. Because the knowledge of both α/β values and the half time for repair of sublethal damage (T (1(2)) ), which are required for these calculations, is quite limited, calculations regarding the equivalence of LDR and PDR treatments have been performed for a wide range of values of α/β and T (1(2)) . The results are presented graphically as PDR/LDR dose ratios and as ratios of the PDR/LDR tumor control probabilities. Results: If the condition that total physical dose and overall time of a PDR treatment must be exactly identical to the values for the corresponding LDR treatment regimen is not applied, there appears

  9. Radiotherapy and brachytherapy

    International Nuclear Information System (INIS)

    2007-02-01

    This presentation first defines the radiotherapy and brachytherapy techniques, indicates the used ionizing radiations (electromagnetic and particles), describes the mechanisms and processes of action of ionizing radiations: they can be physical by photon-matter interactions (Compton effect and photoelectric effect) or due to electron-matter interactions (excitation, ionization), physical-chemical by direct or indirect action (DNA damage), cellular (mitotic or apoptotic death), tissue (sane and tumorous tissues and differential effect). It discusses the biological efficiency of these treatments which depends on different parameters: intrinsic radio-sensitivity, time (session fractioning and organisation in time), oxygen, radiation quality, cellular cycle, dose rate, temperature. It presents the different types of radiotherapy: external radiotherapy (general sequence, delineation, dosimetry, protection of critical organs, treatment session, quality control, monitoring consultation) and briefly presents some specific techniques (total body irradiation, total cutaneous electron therapy, pre-operation radiotherapy, radio-surgery, hadron-therapy). It proposes an overview of the main indications for this treatment: brain tumours, upper aero digestive tract tumours, bronchial tumours, oesophagus, stomach and pancreas tumours, breast tumours, cervix cancer, rectum tumour, and so on, and indicates the possible associated treatments. The next part addresses brachytherapy. It presents the principles and comments the differences with radiotherapy. It indicates the used radio-elements (Caesium 137, Iridium 192, Iodine 125), describes the implementation techniques (plastic tubes, use of iodine 125, intracavitary and endo-luminal radiation therapy). It proposes an overview of the different treated tumours (skin, breast, prostates, bronchial, oesophagus, ENT) and indicates possible early and late secondary effects for different organs

  10. Feasibility of combined operation and perioperative intensity-modulated brachytherapy of advanced/recurrent malignancies involving the skull base

    Energy Technology Data Exchange (ETDEWEB)

    Strege, R.J.; Eichmann, T.; Mehdorn, H.M. [University Hospital Schleswig-Holstein, Kiel (Germany). Dept. of Neurosurgery; Kovacs, G.; Niehoff, P. [University Hospital Schleswig-Holstein, Kiel (Germany). Interdisciplinary Brachytherapy Center; Maune, S. [University Hospital Schleswig-Holstein, Kiel (Germany). Dept. of Otolaryngology; Holland, D. [University Hospital Schleswig-Holstein, Kiel (Germany). Dept. of Ophthalmology

    2005-02-01

    Purpose: To assess the technical feasibility and toxicity of combined operation and perioperative intensity-modulated fractionated interstitial brachytherapy (IMBT) in advanced-stage malignancies involving the skull base with the goal of preserving the patients' senses of sight. Patients and Methods: This series consisted of 18 consecutive cases: ten patients with paranasal sinus carcinomas, five with sarcomas, two with primitive neuroectodermal tumors (PNETs), and one with parotid gland carcinoma. After, in most cases, subtotal surgical resection (R1-R2: carried out so that the patients' senses of sight were preserved), two to twelve (mean five) afterloading plastic tubes were placed into the tumor bed. IMBT was performed with an iridium-192 stepping source in pulsed-dose-rate/high-dose-rate (PDR/HDR) afterloading technique. The total IMBT dose, ranging from 10 to 30 Gy, was administered in a fractionated manner (3-5 Gy/day, 5 days/week). Results: Perioperative fractionated IMBT was performed in 15 out of 18 patients and was well tolerated. Complications that partially prevented or delayed IMBT in some cases included cerebrospinal fluid leakage (twice), meningitis (twice), frontal brain syndrome (twice), afterloading tube displacement (twice), seizure (once), and general morbidity (once). No surgery- or radiation-induced injuries to the cranial nerves or eyes occurred. Median survival times were 33 months after diagnosis and 16 months after combined operation and IMBT. Conclusion: Perioperative fractionated IMBT after extensive but vision-preserving tumor resection seems to be a safe and well-tolerated treatment of advanced/recurrent malignancies involving the skull base. These preliminary state suggest that combined operation and perioperative fractionated IMBT is a palliative therapeutic option in the management of fatal malignancies involving the base of the skull, a strategy which leaves the patients' visual acuity intact. (orig.)

  11. Biological effective dose evaluation in gynaecological brachytherapy: LDR and HDR treatments, dependence on radiobiological parameters, and treatment optimisation.

    Science.gov (United States)

    Bianchi, C; Botta, F; Conte, L; Vanoli, P; Cerizza, L

    2008-10-01

    This study was undertaken to compare the biological efficacy of different high-dose-rate (HDR) and low-dose-rate (LDR) treatments of gynaecological lesions, to identify the causes of possible nonuniformity and to optimise treatment through customised calculation. The study considered 110 patients treated between 2001 and 2006 with external beam radiation therapy and/or brachytherapy with either LDR (afterloader Selectron, (137)Cs) or HDR (afterloader microSelectron Classic, (192)Ir). The treatments were compared in terms of biologically effective dose (BED) to the tumour and to the rectum (linear-quadratic model) by using statistical tests for comparisons between independent samples. The difference between the two treatments was statistically significant in one case only. However, within each technique, we identified considerable nonuniformity in therapeutic efficacy due to differences in fractionation schemes and overall treatment time. To solve this problem, we created a Microsoft Excel spreadsheet allowing calculation of the optimal treatment for each patient: best efficacy (BED(tumour)) without exceeding toxicity threshold (BED(rectum)). The efficacy of a treatment may vary as a result of several factors. Customised radiobiological evaluation is a useful adjunct to clinical evaluation in planning equivalent treatments that satisfy all dosimetric constraints.

  12. Phantom study of radiation doses outside the target volume brachytherapy versus external radiotherapy of early breast cancer

    International Nuclear Information System (INIS)

    Johansson, Bengt; Persson, Essie; Westman, Gunnar; Persliden, Jan

    2003-01-01

    Background and purpose: Brachytherapy is sometimes suggested as an adjuvant treatment after surgery of some tumours. When introducing this, it would be useful to have an estimate of the dose distribution to different body sites, both near and distant to target, comparing conventional external irradiation to brachytherapy. The aim of the present study was to determine radiation doses with both methods at different body sites, near and distant to target, in an experimental situation on an operated left sided breast cancer on a female Alderson phantom. Methods: Five external beam treatments with isocentric tangential fields were given by a linear accelerator. A specified dose of 1.0 Gy was given to the whole left sided breast volume. Five interstitial brachytherapy treatments were given to the upper, lateral quadrant of the left breast by a two plane, 10 needles implant. A dose of 1.0 Gy specified according to the Paris system was administered by a pulsed dose rate afterloading machine. Absorbed dose in different fixed dose points were measured by thermoluminescence dosimeters. Results: Both methods yielded an absorbed dose of the same size to the bone marrow and internal organs distant to target, 1.0-1.4% of the prescribed dose. There was a trend of lower doses to the lower half of the trunk and higher doses to the upper half of the trunk, respectively, by brachytherapy. A 90% reduction of absorbed dose with brachytherapy compared to external irradiation was found in the near-target region within 5 cm from target boundary where parts of the left lung and the heart are situated. If an adjuvant dose of 50 Gy is given with the external radiotherapy and brachytherapy, the absorbed dose in a part of the myocardium could be reduced from 31.8 to 2.1 Gy. Conclusions: Near target, brachytherapy yielded a considerably lower absorbed dose which is of special importance when considering radiation effects on the myocard and lungs. We could not demonstrate any difference of

  13. Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson Tedgren, Aasa

    2007-11-15

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The 192Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI

  14. Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden

    International Nuclear Information System (INIS)

    Carlsson Tedgren, Aasa

    2007-11-01

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192 Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192 Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the ±3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The 192 Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI

  15. Dose mapping of the rectal wall during brachytherapy with an array of scintillation dosimeters

    International Nuclear Information System (INIS)

    Cartwright, L. E.; Suchowerska, N.; Yin, Y.; Lambert, J.; Haque, M.; McKenzie, D. R.

    2010-01-01

    Purpose: In pelvic brachytherapy treatments, the rectum is an organ at risk. The authors have developed an array of scintillation dosimeters suitable for in vivo use that enables quality assurance of the treatment delivery and provides an alert to potential radiation accidents. Ultimately, this will provide evidence to direct treatment planning and dose escalation and correlate dose with the rectal response. Methods: An array of 16 scintillation dosimeters in an insertable applicator has been developed. The dosimeters were calibrated simultaneously in a custom designed circular jig before use. Each dosimeter is optically interfaced to a set of pixels on a CCD camera located outside the treatment bunker. A customized software converts pixel values into dose rate and accumulates dose for presentation during treatment delivery. The performance of the array is tested by simulating brachytherapy treatments in a water phantom. The treatment plans were designed to deliver a known dose distribution on the surface of the rectal applicator, assumed to represent the dose to the rectal wall. Results: The measured doses were compared to those predicted by the treatment plan and found to be in agreement to within the uncertainty in measurement, usually within 3%. The array was also used to track the progression of the source as it moved along the catheter. The measured position was found to agree with the position reported by the afterloader to within the measurement uncertainty, usually within 2 mm. Conclusions: This array is capable of measuring the actual dose received by each region of the rectal wall during brachytherapy treatments. It will provide real time monitoring of treatment delivery and raise an alert to a potential radiation accident. Real time dose mapping in the clinical environment will give the clinician additional confidence to carry out dose escalation to the tumor volume while avoiding rectal side effects.

  16. Dosimetry audit on the accuracy of {sup 192}Ir brachytherapy source strength determinations in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson Tedgren, Aasa

    2007-11-15

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in {sup 192}Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an {sup 192}Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the {+-}3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The {sup 192}Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI.

  17. Erectile function after prostate brachytherapy

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Wallner, Kent E.; Galbreath, Robert W.; Anderson, Richard L.; Kurko, Brian S.; Lief, Jonathan H.; Allen, Zachariah A.

    2005-01-01

    Purpose: To evaluate erectile function after permanent prostate brachytherapy using a validated patient-administered questionnaire and to determine the effect of multiple clinical, treatment, and dosimetric parameters on penile erectile function. Methods and materials: A total of 226 patients with preimplant erectile function determined by the International Index of Erectile Function (IIEF) questionnaire underwent permanent prostate brachytherapy in two prospective randomized trials between February 2001 and January 2003 for clinical Stage T1c-T2c (2002 American Joint Committee on Cancer) prostate cancer. Of the 226 patients, 132 were potent before treatment and, of those, 128 (97%) completed and returned the IIEF questionnaire after brachytherapy. The median follow-up was 29.1 months. Potency was defined as an IIEF score of ≥13. The clinical, treatment, and dosimetric parameters evaluated included patient age; preimplant IIEF score; clinical T stage; pretreatment prostate-specific antigen level; Gleason score; elapsed time after implantation; preimplant nocturnal erections; body mass index; presence of hypertension or diabetes mellitus; tobacco consumption; the volume of the prostate gland receiving 100%, 150%, and 200% of the prescribed dose (V 100/150/200 ); the dose delivered to 90% of the prostate gland (D 90 ); androgen deprivation therapy; supplemental external beam radiotherapy (EBRT); isotope; prostate volume; planning volume; and radiation dose to the proximal penis. Results: The 3-year actuarial rate of potency preservation was 50.5%. For patients who maintained adequate posttreatment erectile function, the preimplant IIEF score was 29, and in patients with brachytherapy-related ED, the preimplant IIEF score was 25. The median time to the onset of ED was 5.4 months. After brachytherapy, the median IIEF score was 20 in potent patients and 3 in impotent patients. On univariate analysis, the preimplant IIEF score, patient age, presence of nocturnal

  18. Development of a semiautomatic cutting machine for the fabrication of 137Cs-brachytherapy sources

    International Nuclear Information System (INIS)

    Avhad, B.G.; Dutta, M.L.; Saxena, S.K.; Dash, A.

    2004-01-01

    Cesium-137 sources are used in brachytherapy for the treatment of gynaecological cancers.The process of source preparation entails the vitrification of radioactive glass, its conversion into glass spheres, subsequent filling of spheres into platinum moulds and cutting of sources into the tubular form of dimension 1.5 mm(OD) x 5 mm(l). The large scale production of these sources demands the remote cutting operations within 4 inch thick lead shielded processing plants. This paper describes the development of a semi-automatic cutting machine, which can be used in the large scale production of 137 Cs brachytherapy sources. (author)

  19. Intracavitary afterloading boost in anal canal carcinoma. Results, function and quality of life

    Energy Technology Data Exchange (ETDEWEB)

    Vordermark, D.; Flentje, M.; Koelbl, O. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie; Sailer, M. [Wuerzburg Univ. (Germany). Klinik fuer Chirurgie

    2001-05-01

    Background: First clinical data on a new intracavitary afterloading boost method for anal canal carcinoma is reported. Patients and Methods: 20 consecutive patients (T1 5%, T2 70%, T3 20%, T4 5%; N0 75%, N1 10%, N2 15%; all M0) treated with external beam pelvic radiotherapy (median dose 56 Gy, range 46-64 Gy), simultaneous 5-FU and mitomycin (in 75%) and an intracavitary afterloading boost (one or two fractions of 5 Gy at 5 mm depth) were analyzed after a mean {+-}SD follow-up for living patients of 4.4{+-}2.1 years. Quality of life (QoL) and anorectal manometry parameters were assessed in ten colostomy-free survivors. Results: Overall, recurrence-free and colostomy-free survival at 5 years were 84%, 79% and 69%, respectively. No death was tumorrelated. The only local failure was successfully salvaged by local excision. All three colostomies were performed for toxicity. Resting pressure and maximum squeeze pressure of the anal sphincter were reduced by 51% and 71%, as compared with control subjects, but quality of life was similar compared to healthy volunteers. Conclusion: the described regimen is highly effective but associated with increased toxicity. (orig.) [German] Hintergrund: Erste klinische Ergebnisse einer neuen Methode zur intrakavitaeren Afterloading-Boost-Bestrahlung des Analkanalkarzinoms werden vorgestellt. Patienten und Methoden: 20 in Folge behandelte Patienten (T1 5%, T2 70%, T3 20%, T4 5%, N0 75%, N1 10%, N2 15 %; alle M0) erhielten eine perkutane Bestrahlung (mediane Dosis 56 Gy, 46-64 Gy), simultan 5-FU und Mitomycin (75%) und einen intrakavitaeren Afterloading-Boost (eine oder zwei Fraktionen mit je 5 Gy in 5 mm Tiefe). Der mittlere Nachbeobachtungszeitraum lebender Patienten betrug 4,4{+-}2,1 Jahre. Zehn kolostomiefrei Ueberlebende wurden bezueglich Lebensqualitaet und anorektaler Manometriewerte untersucht. Ergebnisse: Gesamtueberleben, rezidivfreies und kolostomiefreies Ueberleben nach 5 Jahren betrugen 84%, 79% und 69%. Kein Todesfall war

  20. A rectum shield for the circular applicator system of a selectron unit (HDR and LDR afterloading)

    International Nuclear Information System (INIS)

    Hetzel, H.; McCoy, M.; Kamleitner, H.; Frommhold, H.

    1987-01-01

    In order to decrease the morbidity rate after combined radiotherapy of the cervix carcinoma, a tungsten shield 3 and 5 mm thick for the rectum has been developed by the authors which is applied with the ring and pin applicator of the selectron unit (LDR and HDR afterloading). The isodose curves were measured in a plexiglas phantom, and the radiation dose at the reference points was determined by means of a ionization dosemeter. The phantom measurements were performed with the same arrangement of sources as applied in radiotherapy. The measurements showed a dose reduction at point Rmax of 33% (HDR) and 44% (LDR) with the tungsten shield 5 mm thick. (orig.) [de

  1. Flushing-free film test of "1"9"2Ir accuracy of position and step distance for afterloading systems

    International Nuclear Information System (INIS)

    Lu Feng; Chen Rui; Shang Yunying; Chen Yue; Min Nan; Chen Yingmin; Deng Daping

    2014-01-01

    Objective: To study the method of measuring the position accuracy and the step distance accuracy of afterloading system with "1"9"2Ir source by using flushing-free film. Methods: The position accuracy and the step distance accuracy of a China-made afterloading system with "1"9"2Ir source was measured by using GAFCHROMIC"® EBT"3 flushing-free film. The film was scanned to proper image format, required by dose analysis software, by EPSON PREFACTION V700 PHOTO scanner. Then images are analyzed by using film dose analysis software in SNC Patient 5.2. Results: With focus on the center of active section of source, the position accuracy of this afterloading system with "1"9"2Ir source was -0.75 mm. Using film analysis could make the step point to tell apart if the step distance was 5 mm away by the method of film analysis, but couldnot make it to tell apart if the step distance was 2.5 mm away. The 2.5 mm step distance accuracy could be judged if the distance between the 1"s"t point and the 3"r"d point was 5 mm, then the 2.5 mm step distance could be deemed to no deviation. The 5 mm step distance of this afterloading system had no deviation in continuous 9 step points measured by flushing-free film. The indirect measuring results of the 2.5 mm step distance had no deviation as well. The position accuracy of this afterloading system measured with the flushing-free film accorded with the national standards. Conclusions: The method of measuring the position accuracy and the step distance accuracy of the afterloading system with "1"9"2Ir source by using flushing-free film is technically feasible. (authors)

  2. The present state of brachytherapy practice in the Czech Republic

    Energy Technology Data Exchange (ETDEWEB)

    Zackova, H; Drabkova, A [National Radiation Protection Institute, Prague (Czech Republic)

    1996-12-31

    In spite of the fact that radiotherapy departments in the Czech republic have been following the general European and world trends in brachytherapy techniques and that they are installing the new remote AFL systems, the reserves of radium sources are still considerably high and not all professionals carry out their applications of radioactive sources by (at least) manual AFL. In near future the attention should be paid to the diminution of the unnecessary radium reserves at that radiotherapy departments where the small number of applications is executed or where the new remote AFL systems are used. For professionals practically thorough radiation protection is assured when new remote AFL systems are used. But in this case an attention should be paid to the radiation safety of the patient because of the potential exposures when high dose rate systems would failed. The likelihood of this unwanted cases can only be decreased when Quality Assurance programs is introduced into practice.

  3. Modeling volume effects of experimental brachytherapy in the rat rectum: uncovering the limitations of a radiobiologic concept

    International Nuclear Information System (INIS)

    Johannessen, Hans-Olaf; Dale, Einar; Hellebust, Taran P.; Olsen, Dag R.; Nesland, Jahn M.; Giercksky, Karl-Erik

    2002-01-01

    Purpose: To analyze the significance of volume effects in experimental brachytherapy, based on modeling normal tissue complication probability. Methods and Materials: Experimental brachytherapy in the rat rectum was based on an eight-step 2.5-mm step size source configuration for 192 Ir, afterloaded into an unshielded polystyrene applicator. Volume effects were studied using a half-circumferential lead-shielded applicator and a shorter (two-step) source configuration. The main end point was rectal stenosis. Results: Rectal stenosis was always caused by a radiation ulcer. With the shielded configuration, single-dose ED 50 (50% incidence of rectal stenosis) increased from 23 Gy to 36.5 Gy. Single-dose ED 50 for the short configuration was 77.9 Gy. The data showed a reasonable fit to a three-parameter version of the biophysical model described by Jackson et al. (1995). This model assumes that organs consist of a large number of radiobiologically independent subunits and that radiation causes a complication if the fraction of the organ damaged is greater than its functional reserve. The fraction of the organ damaged is calculated summing over fractions of the organ damaged at each dose level. The calculated mean functional reserve (ν 50 ) of the rat rectum, assuming a cumulative functional reserve distribution in the group of experimental rats, was 0.53. Conclusions: The volume effect observed within small brachytherapy volumes agreed well with clinical experience of large tolerance doses in contact X-ray therapy. However, the ν 50 value was comparable to the high functional reserve value reported for liver. Experimental volume effects probably reflect repair processes originating in the areas adjacent to small radiation fields of brachytherapy more than the radiobiologic characteristics of the cells in the irradiated volume

  4. Comparative study of reference points by dosimetric analyses for late complications after uniform external radiotherapy and high-dose-rate brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Chen, S.-W.; Liang, J.-A.; Yeh, L.-S.; Yang, S.-N.; Shiau, A.-C.; Lin, F.-J.

    2004-01-01

    Purpose: This study aimed to correlate and compare the predictive values of rectal and bladder reference doses of uniform external beam radiotherapy without shielding and high-dose-rate intracavitary brachytherapy (HDRICB) with late sequelae in patients with uterine cervical cancer. Methods and materials: Between September 1992 and December 1998, 154 patients who survived more than 12 months after treatment were studied. Initially, they were treated with 10-MV X-rays (44 to 45 Gy/22 to 25 fractions over 4 to 5 weeks) to the whole pelvis, after which HDRICB was performed using 192 Ir remote afterloading at 1-week intervals for 4 weeks. The standard prescribed dose for each HDRICB was 6.0 Gy to point A. Patient- and treatment-related-factors were evaluated for late rectal complications using logistic regression modeling. Results: The probability of rectal complications showed better correlation of dose-response with increasing total ICRU (International Committee on Radiotherapy Units and Measurements) rectal dose. Multivariate logistic regression demonstrated a high risk of late rectal sequelae in patients who developed rectal complications (p 0.0001;relative risk, 15.06;95% CI, 2.89∼43.7) and total ICRU rectal dose greater than 16 Gy (p = 0.02;relative risk, 2.07;95% CI, 1.13∼4.55). The high risk factors for bladder complications were seen in patients who developed rectal complications (p = 0.0001;relative risk, 15.2;95% CI, 2.81∼44.9) and total ICRU bladder dose greater than 24 Gy (p = 0.02;relative risk, 8.93;95% CI, 1.79∼33.1). Conclusion: This study demonstrated the predictive value of ICRU rectal and bladder reference dosing in HDRICB for patients receiving uniform external beam radiation therapy without central shielding. Patients who had a total ICRU rectal dose greater than 16 Gy, or a total ICRU bladder dose over 24 Gy, were at risk of late sequelae

  5. Impact of aortic root size on left ventricular afterload and stroke volume.

    Science.gov (United States)

    Sahlén, Anders; Hamid, Nadira; Amanullah, Mohammed Rizwan; Fam, Jiang Ming; Yeo, Khung Keong; Lau, Yee How; Lam, Carolyn S P; Ding, Zee Pin

    2016-07-01

    The left ventricle (LV) ejects blood into the proximal aorta. Age and hypertension are associated with stiffening and dilation of the aortic root, typically viewed as indicative of adverse remodeling. Based on analytical considerations, we hypothesized that a larger aortic root should be associated with lower global afterload (effective arterial elastance, EA) and larger stroke volume (SV). Moreover, as antihypertensive drugs differ in their effect on central blood pressure, we examined the role of antihypertensive drugs for the relation between aortic root size and afterload. We studied a large group of patients (n = 1250; 61 ± 12 years; 78 % males; 64 % hypertensives) from a single-center registry with known or suspected coronary artery disease. Aortic root size was measured by echocardiography as the diameter of the tubular portion of the ascending aorta. LV outflow tract Doppler was used to record SV. In the population as a whole, after adjusting for key covariates in separate regression models, aortic root size was an independent determinant of both SV and EA. This association was found to be heterogeneous and stronger in patients taking a calcium channel blocker (CCB; 10.6 % of entire population; aortic root size accounted for 8 % of the explained variance of EA). Larger aortic root size is an independent determinant of EA and SV. This association was heterogeneous and stronger in patients on CCB therapy.

  6. Intracavitary afterloading boost in anal canal carcinoma. Results, function and quality of life

    International Nuclear Information System (INIS)

    Vordermark, D.; Flentje, M.; Koelbl, O.; Sailer, M.

    2001-01-01

    Background: First clinical data on a new intracavitary afterloading boost method for anal canal carcinoma is reported. Patients and Methods: 20 consecutive patients (T1 5%, T2 70%, T3 20%, T4 5%; N0 75%, N1 10%, N2 15%; all M0) treated with external beam pelvic radiotherapy (median dose 56 Gy, range 46-64 Gy), simultaneous 5-FU and mitomycin (in 75%) and an intracavitary afterloading boost (one or two fractions of 5 Gy at 5 mm depth) were analyzed after a mean ±SD follow-up for living patients of 4.4±2.1 years. Quality of life (QoL) and anorectal manometry parameters were assessed in ten colostomy-free survivors. Results: Overall, recurrence-free and colostomy-free survival at 5 years were 84%, 79% and 69%, respectively. No death was tumorrelated. The only local failure was successfully salvaged by local excision. All three colostomies were performed for toxicity. Resting pressure and maximum squeeze pressure of the anal sphincter were reduced by 51% and 71%, as compared with control subjects, but quality of life was similar compared to healthy volunteers. Conclusion: the described regimen is highly effective but associated with increased toxicity. (orig.) [de

  7. TU-C-201-02: Clinical Implementation of HDR: Afterloader and Applicator Selection

    Energy Technology Data Exchange (ETDEWEB)

    Esthappan, J. [Washington University School of Medicine (United States)

    2015-06-15

    Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for each institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.

  8. Dosimetry in intravascular brachytherapy

    International Nuclear Information System (INIS)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing 32 P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  9. THYROID HORMONE REVERSES AGING-INDUCED MYOCARDIAL FATTY ACID OXIDATION DEFECTS AND IMPROVES THE RESPONSE TO ACUTELY INCREASED AFTERLOAD

    Energy Technology Data Exchange (ETDEWEB)

    Ledee, Dolena; Portman, Michael A.; Kajimoto, Masaki; Isern, Nancy G.; Olson, Aaron

    2013-06-07

    Background: Subclinical hypothyroidism occurs during aging in humans and mice and may contribute to development of heart failure. Aging also impairs myocardial fatty acid oxidation, causing increased reliance on flux through pyruvate dehydrogenase (PDH) to maintain function. We hypothesize that the metabolic changes in aged hearts make them less tolerant to acutely increased work and that thyroid hormone reverses these defects. Methods: Studies were performed on young (Young, 4-6 months) and aged (Old, 22-24 months) C57/BL6 mice at standard (50 mmHg) and high afterload (80 mmHg). Another aged group received thyroid hormone for 3 weeks (Old-TH, high afterload only). Function was measured in isolated working hearts along with substrate fractional contributions (Fc) to the citric acid cycle (CAC) using perfusate with 13C labeled lactate, pyruvate, glucose and unlabeled palmitate and insulin. Results: Cardiac function was similar between Young and Old mice at standard afterload. Palmitate Fc was reduced but no individual carbohydrate contributions differed. CAC and individual substrate fluxes decreased in aged. At high afterload, -dP/dT was decreased in Old versus Young. Similar to low afterload, palmitate Fc was decreased in Old. Thyroid hormone reversed aging-induced changes in palmitate Fc and flux while significantly improving cardiac function. Conclusion: The aged heart shows diminished ability to increase cardiac work due to substrate limitations, primarily impaired fatty acid oxidation. The heart accommodates slightly by increasing efficiency through oxidation of carbohydrate substrates. Thyroid hormone supplementation in aged mice significantly improves cardiac function potentially through restoration of fatty acid oxidation.

  10. WE-DE-201-08: Multi-Source Rotating Shield Brachytherapy Apparatus for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Dadkhah, H; Wu, X [University of Iowa, Iowa City, Iowa (United States); Kim, Y; Flynn, R [University of Iowa Hospitals and Clinics, Iowa City, IA (United States)

    2016-06-15

    Purpose: To introduce a novel multi-source rotating shield brachytherapy (RSBT) apparatus for the precise simultaneous angular and linear positioning of all partially-shielded 153Gd radiation sources in interstitial needles for treating prostate cancer. The mechanism is designed to lower the detrimental dose to healthy tissues, the urethra in particular, relative to conventional high-dose-rate brachytherapy (HDR-BT) techniques. Methods: Following needle implantation, the delivery system is docked to the patient template. Each needle is coupled to a multi-source afterloader catheter by a connector passing through a shaft. The shafts are rotated by translating a moving template between two stationary templates. Shaft walls as well as moving template holes are threaded such that the resistive friction produced between the two parts exerts enough force on the shafts to bring about the rotation. Rotation of the shaft is then transmitted to the shielded source via several keys. Thus, shaft angular position is fully correlated with the position of the moving template. The catheter angles are simultaneously incremented throughout treatment as needed, and only a single 360° rotation of all catheters is needed for a full treatment. For each rotation angle, source depth in each needle is controlled by a multi-source afterloader, which is proposed as an array of belt-driven linear actuators, each of which drives a source wire. Results: Optimized treatment plans based on Monte Carlo dose calculations demonstrated RSBT with the proposed apparatus reduced urethral D{sub 1cc} below that of conventional HDR-BT by 35% for urethral dose gradient volume within 3 mm of the urethra surface. Treatment time to deliver 20 Gy with multi-source RSBT apparatus using nineteen 62.4 GBq {sup 153}Gd sources is 117 min. Conclusions: The proposed RSBT delivery apparatus in conjunction with multiple nitinol catheter-mounted platinum-shielded {sup 153}Gd sources enables a mechanically feasible

  11. About brachytherapy for the handling of cancer

    International Nuclear Information System (INIS)

    Campos, Tarcisio P.R.; Silva, Nilton O.; Damaso, Renato S.; Costa, Helder R.; Borges, Paulo H.R.; Mendes, Bruno M.

    2000-01-01

    The technique of brachytherapy is argued in this article. The 'hardware' and 'necessary software' for the handling are summarily presented. Being the macro-dosimetry an important stage in the radiation therapy procedure, a simplified method of doses evaluation in conventional brachytherapy is presented. In an illustrative form, isodoses of a three-dimensional distribution of linear sources are drawn on a digitalized X-ray picture, exemplifying the handling of breast brachytherapy by sources of iridium

  12. Dosimetry experience of 192IR sources used In HDR brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Daci, Lulzime; Myrku, Rodina Cela

    2013-01-01

    Purpose/Objective: The 192IR Sources are the most commonly used in radiotherapy treatments HDR worldwide. According to international recommendations on quality assurance in HDR brachytherapy, an acceptance test based on the determination of the source strength of any new source shall be carried out before first application to verify the manufacturer’s calibration data. The present paper gives the experimental determination of the source strength for our brachytherapy sources used until now in brachytherapy treatments. Materials/Methods: At Mother Teresa University Hospital we have a cost-effective gynecological brachytherapy unit from Eckert & Ziegler BEBIG named GyneSource® that is a five channel HDR after loader equipped with an 192IR source. The software used is HDR plus™ 2.5 that delivers an optimized treatment plan and makes the process especially fast and we use intracavitary BEBIG applicators. From April 2009 up to December 2012, we have imported nine HDR 192IR Sources. The exchange of the source and acceptance test is done by the physicist of the clinic once the source is imported. The measurements are done with a Well-type ionization chamber HDR1000 Plus and the electrometer used is MAX4000. Only seven sources are compared as we miss the dosimetry data of the first source, and the forth source was not measured and not used because the machine was not working in that time. Results/Conclusions: Eight sources were accepted for clinically use as the measurement were within the tolerance. The source number four with e deviation of -1.92% has been double checked compared with a free in-air measurement with farmer type chamber that gave a deviation to source certificate of 4% that is still inside the tolerance to accept a source for clinical use. The deviations of measured Air Kerma rate to the value of the sources certificates of all our used 192IR sources are less than 2%, which are within the tolerance. The checked value of updated source strength in

  13. High dose rate intracavitary afterloading irradiation in malignant inoperable obturation of bile ducts

    Energy Technology Data Exchange (ETDEWEB)

    Itami, J.; Saegusa, K.; Mamiya, T.; Miyoshi, T.; Arimizu, N.; Tsuchiya, Y.; Ohto, M.

    1986-02-01

    After decompression of the bile duct with PTCD, seven patients with carcinomas of the bile ducts were submitted to an intracavitary Ir-afterloading irradiation performed according to the high-dose-rate method with a Buchler device. Most of the patients were irradiated with 30 Gy in two fractions. Five patients were also exposed to percutaneous radiation with 40 to 50 Gy. Local control was achieved in six patients. One patient developed a locoregional recurrence which was possibly due to a so-called 'geographic miss'. In one patient a benign fibrotic stenosis of the bile duct was found at the site of most intensive irradiation. Intracavitary irradiation is very important in the treatment of malignant of bile ducts. However, there is an urgent need of research with regard to the combined method with percutaneous irradiation and to the optimum fractionation of intracavitary high dose rate irradiation.

  14. Clinical experiences with Curietron after-loading apparatus in patients with gynecological carcinomas

    International Nuclear Information System (INIS)

    Vigvary, Zoltan; Csoemoer, Sandor; Feher, Laszlo; Hintalan, Albert; Semmelweis Orvostudomanyi Egyetem, Budapest

    1985-01-01

    On the basis of experiences the afterloading method using sup(137)Cs source with activities between 15 and 19.2 mCi seems to be effective in a large number of cervix-corpus carcinomas, when the parameters are identified exactly, and correspond with the admissible dose. By the individual dose planning a tumour dose under the threshold limit on the wall of the bladder and rectum can be achieved. According to calculations it is between 5-30 Gy on the posterior wall of the bladder, and 15-35 Gy on the anterior wall of rectum. The patients tolerate well the relatively long duration of treatment (48-60 hs) with the help of mild sedatives. The small intestines are considerably safe by this low R/min protracted method. These explain the lack of complications in the intestines. The application, the localization and the nursing can be performed in radiation-free environment. (author)

  15. Afterloading technique for interstitial irradiation of lesions in deep-seated organs

    International Nuclear Information System (INIS)

    Kitagawa, T.; Kakehi, M.; Kunieda, T.; Tsukiyama, I.; Hamada, M.; Inakoshi, H.; Sakudo, M.; Suemasu, K.; Matsumoto, K.; Yoneyama, T.; Iizuka, T.; Nomura, K.; Kawachi, K.

    1982-01-01

    An afterloading procedure using 192 Ir seeds was developed for the control of both localized primary lesions that are difficult to remove and superficial residual lesions that remain after the partial removal of tumors in relatively inaccessible, deep-seated organs. This technique makes possible the delivery of a minimal radiation dose to lesions in deep-seated organs. Fewer complications result, the seeds can be adjusted at appropriate intervals in proportion to the amount of radioactivity desired, and radiation exposure to personnel can be reduced. This paper describes the techniques and apparatus used to place the seeds in the tubing. Primary lesions of the urinary bladder, the prostate gland, and the esophagus, residual lesions in the brain and lung, and metastases in intrapelvic lymph nodes were treated. No technical difficulties or complications were encountered. Radiation exposures to personnel were minimized. The results indicate that the procedure has practical applications

  16. Diabetes Mellitus Associates with Increased Right Ventricular Afterload and Remodeling in Pulmonary Arterial Hypertension.

    Science.gov (United States)

    Whitaker, Morgan E; Nair, Vineet; Sinari, Shripad; Dherange, Parinita A; Natarajan, Balaji; Trutter, Lindsey; Brittain, Evan L; Hemnes, Anna R; Austin, Eric D; Patel, Kumar; Black, Stephen M; Garcia, Joe G N; Yuan Md PhD, Jason X; Vanderpool, Rebecca R; Rischard, Franz; Makino, Ayako; Bedrick, Edward J; Desai, Ankit A

    2018-06-01

    Diabetes mellitus is associated with left ventricular hypertrophy and dysfunction. Parallel studies have also reported associations between diabetes mellitus and right ventricular dysfunction and reduced survival in patients with pulmonary arterial hypertension. However, the impact of diabetes mellitus on the pulmonary vasculature has not been well characterized. We hypothesized that diabetes mellitus and hyperglycemia could specifically influence right ventricular afterload and remodeling in patients with Group I pulmonary arterial hypertension, providing a link to their known susceptibility to right ventricular dysfunction. Using an adjusted model for age, sex, pulmonary vascular resistance, and medication use, associations of fasting blood glucose, glycated hemoglobin, and the presence of diabetes mellitus were evaluated with markers of disease severity in 162 patients with pulmonary arterial hypertension. A surrogate measure of increased pulmonary artery stiffness, elevated pulmonary arterial elastance (P = .012), along with reduced log(pulmonary artery capacitance) (P = .006) were significantly associated with the presence of diabetes mellitus in patients with pulmonary arterial hypertension in a fully adjusted model. Similar associations between pulmonary arterial elastance and capacitance were noted with both fasting blood glucose and glycated hemoglobin. Furthermore, right ventricular wall thickness on echocardiography was greater in pulmonary arterial hypertension patients with diabetes, supporting the link between right ventricular remodeling and diabetes. Cumulatively, these data demonstrate that an increase in right ventricular afterload, beyond pulmonary vascular resistance alone, may influence right ventricular remodeling and provide a mechanistic link between the susceptibility to right ventricular dysfunction in patients with both diabetes mellitus and pulmonary arterial hypertension. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Effect of permanent 103Pd radioactive seed implantation on brachytherapy of malignant tumor

    International Nuclear Information System (INIS)

    Chen Ping; Wei Xianzhong; Liu Yanmin; Wu Kaijun; Liang Jianxin; Chen Hanzhang

    2003-01-01

    Objective: To investigate and assess the brachytherapeutic effectiveness of 103 Pd radioactive seeds in malignant tumor therapy. Methods: 196.1-2127.5 MBq 103 Pd seeds were implanted in 21 confirmed malignant tumor patients. The seeds were evenly scattered in 15/21 patients' tumors and peripherally in the remaining 6 cases' tumors. The size and shape, local recurrence and remote metastasis of the tumors were observed. Results: The brachytherapy of 103 Pd seeds in tumor patients resulted in obvious efficacy. No local recurrence and remote metastasis were observed. 19/21 (90.5%) patients scored 0 and 2/21 (9.5%) of them scored 1 in skin acute radiation morbidity scoring criteria within the observation period. Conclusion: The 103 Pd seeds can be safely used in brachytherapy of malignant tumors with lower or medium sensitivity to radiation therapy

  18. Physical aspects of radioisotope brachytherapy

    International Nuclear Information System (INIS)

    1967-01-01

    The present report represents an attempt to provide, within a necessarily limited compass, an authoritative guide to all important physical aspects of the use of sealed gamma sources in radiotherapy. Within the report, reference is made wherever necessary to the more extensive but scattered literature on this subject. While this report attempts to cover all the physical aspects of radioisotope 'brachytherapy' it does not, of course, deal exhaustively with any one part of the subject. 384 refs, 3 figs, 6 tabs

  19. Rectourethral fistula following LDR brachytherapy.

    Science.gov (United States)

    Borchers, Holger; Pinkawa, Michael; Donner, Andreas; Wolter, Timm P; Pallua, Norbert; Eble, Michael J; Jakse, Gerhard

    2009-01-01

    Modern LDR brachytherapy has drastically reduced rectal toxicity and decreased the occurrence of rectourethral fistulas to <0.5% of patients. Therefore, symptoms of late-onset sequelae are often ignored initially. These fistulas cause severe patient morbidity and require interdisciplinary treatment. We report on the occurrence and management of a rectourethral fistula which occurred 4 years after (125)I seed implantation. Copyright 2009 S. Karger AG, Basel.

  20. Radiation safety and gynaecological brachytherapy

    International Nuclear Information System (INIS)

    Crawford, L.

    1985-01-01

    In 1983, the Radiation Control Section of the South Australian Health Commission conducted an investigation into radiation safety practices in gynaecological brachytherapy. Part of the investigation included a study of the transportation of radioactive sources between hospitals. Several deficiences in radiation safety were found in the way these sources were being transported. New transport regulations came into force in South Australia in July 1984 and since then there have been many changes in the transportation procedure

  1. Intravascular brachytherapy for peripheral vascular disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2008-09-01

    Full Text Available Scientific background: Percutaneous transluminal angioplasties (PTA through balloon dilatation with or without stenting, i.e. vessel expansion through balloons with or without of implantation of small tubes, called stents, are used in the treatment of peripheral artery occlusive disease (PAOD. The intravascular vessel irradiation, called intravascular brachytherapy, promises a reduction in the rate of repeated stenosis (rate of restenosis after PTA. Research questions: The evaluation addresses questions on medical efficacy, cost-effectiveness as well as ethic, social and legal implications in the use of brachytherapy in PAOD patients. Methods: A systematic literature search was conducted in August 2007 in the most important medical electronic databases for publications beginning from 2002. The medical evaluation included randomized controlled trials (RCT. The information synthesis was performed using meta-analysis. Health economic modeling was performed with clinical assumptions derived from the meta-analysis and economical assumptions derived from the German Diagnosis Related Groups (G-DRG-2007. Results: Medical evaluation: Twelve publications about seven RCT on brachytherapy vs. no brachytherapy were included in the medical evaluation. Two RCT showed a significant reduction in the rate of restenosis at six and/or twelve months for brachytherapy vs. no brachytherapy after successful balloon dilatation, the relative risk in the meta-analysis was 0.62 (95% CI: 0.46 to 0.84. At five years, time to recurrence of restenosis was significantly delayed after brachytherapy. One RCT showed a significant reduction in the rate of restenosis at six months for brachytherapy vs. no brachytherapy after PTA with optional stenting, the relative risk in the meta-analysis was 0.76 (95% CI: 0.61 to 0.95. One RCT observed a significantly higher rate of late thrombotic occlusions after brachytherapy in the subgroup of stented patients. A single RCT for brachytherapy

  2. Dwell time modulation restrictions do not necessarily improve treatment plan quality for prostate HDR brachytherapy

    International Nuclear Information System (INIS)

    Balvert, Marleen; Gorissen, Bram L; Den Hertog, Dick; Hoffmann, Aswin L

    2015-01-01

    Inverse planning algorithms for dwell time optimisation in interstitial high-dose-rate (HDR) brachytherapy may produce solutions with large dwell time variations within catheters, which may result in undesirable selective high-dose subvolumes. Extending the dwell time optimisation model with a dwell time modulation restriction (DTMR) that limits dwell time differences between neighboring dwell positions has been suggested to eliminate this problem. DTMRs may additionally reduce the sensitivity for uncertainties in dwell positions that inevitably result from catheter reconstruction errors and afterloader source positioning inaccuracies. This study quantifies the reduction of high-dose subvolumes and the robustness against these uncertainties by applying a DTMR to template-based prostate HDR brachytherapy implants. Three different DTMRs were consecutively applied to a linear dose-based penalty model (LD) and a dose-volume based model (LDV), both obtained from literature. The models were solved with DTMR levels ranging from no restriction to uniform dwell times within catheters in discrete steps. Uncertainties were simulated on clinical cases using in-house developed software, and dose-volume metrics were calculated in each simulation. For the assessment of high-dose subvolumes, the dose homogeneity index (DHI) and the contiguous dose volume histogram were analysed. Robustness was measured by the improvement of the lowest D 90% of the planning target volume (PTV) observed in the simulations. For (LD), a DTMR yields an increase in DHI of approximately 30% and reduces the size of the largest high-dose volume by 2–5 cc. However, this comes at a cost of a reduction in D 90% of the PTV of 10%, which often implies that it drops below the desired minimum of 100%. For (LDV), none of the DTMRs were able to improve high-dose volume measures. DTMRs were not capable of improving robustness of PTV D 90% against uncertainty in dwell positions for both models. (paper)

  3. Interstitial prostate brachytherapy. LDR-PDR-HDR

    International Nuclear Information System (INIS)

    Kovacs, Gyoergy; Hoskin, Peter

    2013-01-01

    The first comprehensive overview of interstitial brachytherapy for the management of local or locally advanced prostate cancer. Written by an interdisciplinary team who have been responsible for the successful GEC-ESTRO/EAU Teaching Course. Discusses in detail patient selection, the results of different methods, the role of imaging, and medical physics issues. Prostate brachytherapy has been the subject of heated debate among surgeons and the proponents of the various brachytherapy methods. This very first interdisciplinary book on the subject provides a comprehensive overview of innovations in low dose rate (LDR), high dose rate (HDR), and pulsed dose rate (PDR) interstitial brachytherapy for the management of local or locally advanced prostate cancer. In addition to detailed chapters on patient selection and the use of imaging in diagnostics, treatment guidance, and implantation control, background chapters are included on related medical physics issues such as treatment planning and quality assurance. The results obtained with the different treatment options and the difficult task of salvage treatment are fully discussed. All chapters have been written by internationally recognized experts in their fields who for more than a decade have formed the teaching staff responsible for the successful GEC-ESTRO/EAU Prostate Brachytherapy Teaching Course. This book will be invaluable in informing residents and others of the scientific background and potential of modern prostate brachytherapy. It will also prove a useful source of up-to-date information for those who specialize in prostate brachytherapy or intend to start an interstitial brachytherapy service.

  4. High dose rate brachytherapy for oral cancer

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Koizumi, Masahiko; Ogawa, Kazuhiko; Furukawa, Souhei

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer. (author)

  5. High dose rate brachytherapy for oral cancer.

    Science.gov (United States)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Furukawa, Souhei; Koizumi, Masahiko; Ogawa, Kazuhiko

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer.

  6. The Real-Time Dose Measurement Scintillating Fiber Array for Brachytherapy Procedures

    Science.gov (United States)

    Tynes, Lawrence

    2007-03-01

    Brachytherapy is a treatment modality that uses tiny radioactive sources (few mm in length) by delivering enough doses to kill cancer tumors or plaque build-up. The type of sources used in hospitals include both gamma and beta emitters. Presently, the technique suffers from not having a single detector with the capability of providing accurate dose distribution information within sub-mm accuracy. The current standard is based primarily on well chambers and film dosimetry. The Center for Advanced Medical Instrumentation (CAMI) at Hampton University is developing a Scintillating Fiber Based Beta Detector prototype in collaboration with the National Institute for Standards and Technology (NIST) to address this problem. The device is composed of an array of 1x1 mm^2 scintillating fibers optically coupled to photo-multiplier tubes for photon-to-current conversion. A CAMAC LabView based data acquisition system is used for real time data collection and histogramming, data analysis. A set of data were collected at the nearby Bon Secours DePaul Medical Center using a GammaMed 12i HDR after-loader housing a 6.62 mCi Ir-192 source. Preliminary comparison between our device and film dosimetry will be discussed.

  7. Estimation of frequency, population doses and stochastic risks in brachytherapy in Japan, 1983

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Kumamoto, Yoshikazu; Noda, Yutaka; Nishizawa, Kanae; Furuya, Yoshiro; Iwai, Kazuo.

    1988-01-01

    Based on the replies to a questionnaire distributed throughout Japan in 1983, genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemogenically significant dose (LSD), malignantly significant dose (MSD), and per Caput effective dose equivalent (EDE) from using small sealed radiation sources for radiotherapy were estimated. Annual frequencies of brachytherapy were estimated to be 2.6 x 10 3 for men and 36.3 x 10 3 for women, with a total of 38.9 x 10 3 . The annual frequencies of using afterloading technique were 0.3 x 10 3 for men and 18.8 x 10 3 for women, with a total of 19.1 x 10 3 . The annual population doses per person were 7.9 nGy for GSD, 118 μGy for CMD, 19.3 μGy for LSD, 172 μGy for MSD, and 428 μGy for EDE. The annual collective effective dose equivalent was estimated to be 5.13 x 10 4 man Sv. (Namekawa, K.)

  8. Experience from long-term monitoring of RAKR ratios in 192Ir brachytherapy

    International Nuclear Information System (INIS)

    Carlsson Tedgren, Asa; Bengtsson, Emil; Hedtjaern, Hakan; Johansson, Asa; Karlsson, Leif; Lamm, Inger-Lena; Lundell, Marie; Mejaddem, Younes; Munck af Rosenschoeld, Per; Nilsson, Josef; Wieslander, Elinore; Wolke, Jeanette

    2008-01-01

    Background: Ratios of values of brachytherapy source strengths, as measured by hospitals and vendors, comprise constant differences as, e.g., systematic errors in ion chamber calibration factors and measurement setup. Such ratios therefore have the potential to reveal the systematic changes in routines or calibration services at either the hospital or the vendor laboratory, which could otherwise be hidden by the uncertainty in the source strength values. Methods: The RAKR of each new source in 13 afterloading units at five hospitals were measured by well-type ion chambers and compared to values for the same source stated on vendor certificates. Results: Differences from unity in the ratios of RAKR values determined by hospitals and vendors are most often small and stable around their mean values to within ±1.5%. Larger deviations are rare but occur. A decreasing ratio, seen at two hospitals for the same source, was useful in detecting an erroneous pressure gauge at the vendor's site. Conclusions: Establishing a mean ratio of RAKR values, as measured at the hospital and supplied on the vendor certificate, and monitoring this as a function of time are an easy way for the early detection of problems with equipment or routines at either the hospital or the vendor site

  9. NOTE: Monte Carlo evaluation of kerma in an HDR brachytherapy bunker

    Science.gov (United States)

    Pérez-Calatayud, J.; Granero, D.; Ballester, F.; Casal, E.; Crispin, V.; Puchades, V.; León, A.; Verdú, G.

    2004-12-01

    In recent years, the use of high dose rate (HDR) after-loader machines has greatly increased due to the shift from traditional Cs-137/Ir-192 low dose rate (LDR) to HDR brachytherapy. The method used to calculate the required concrete and, where appropriate, lead shielding in the door is based on analytical methods provided by documents published by the ICRP, the IAEA and the NCRP. The purpose of this study is to perform a more realistic kerma evaluation at the entrance maze door of an HDR bunker using the Monte Carlo code GEANT4. The Monte Carlo results were validated experimentally. The spectrum at the maze entrance door, obtained with Monte Carlo, has an average energy of about 110 keV, maintaining a similar value along the length of the maze. The comparison of results from the aforementioned values with the Monte Carlo ones shows that results obtained using the albedo coefficient from the ICRP document more closely match those given by the Monte Carlo method, although the maximum value given by MC calculations is 30% greater.

  10. Interstitial hyperthermia using 8 MHz radiofrequency and stereotaxic brachytherapy for brain tumors

    International Nuclear Information System (INIS)

    Nishimura, Satoshi

    1990-01-01

    As a preliminary study of the interstitial hyperthermia combined with interstitial irradiation (brachytherapy) for the treatment of malignant brain tumors, we performed an experiment of interstitial hyperthermia of brain tissue of dogs. Nine afterloading tubes, four for needle electrodes and five for thermisters, were inserted in the brain tissue of dogs. Rise and stability of temperature were ascertained, and clinical safety was confirmed. Thereafter this combined therapy was applied on seven cases, in which three were malignant gliomas and four were metastatic tumors. Through the guide tubes, 192 Ir thin wires were implanted stereotaxically, and interstitial irradiation was carried out. After removal of 192 Ir wires, needle electrodes were inserted through the same tubes, and also a thermister was guided at the center of electrodes. And interstitial hyperthermia using 8 MHz radiofrequency was carried out. The results of the treatment were evaluated with CT scan based on criteria of the Japan Neurological Society. In cases of malignant gliomas, 2 PRs (partial remission), and 1 NC (no change) were obtained. In cases of metastatic tumors, 1 CR (complete remission), 2 PRs, 1 NC were obtaind. In cases of NCs, progression of tumors have been suppressed for 10 and 17 months, and still alive. As complication, transient worsening of neurological symptoms were observed in four cases (increased paresis: two cases, nausea and vomiting: two cases). The author have had an impression that interstitial hyperthermia combined with interstitial irradiation might become an effective means of treatment of brain tumors. (author)

  11. Altered Right Ventricular Mechanical Properties Are Afterload Dependent in a Rodent Model of Bronchopulmonary Dysplasia

    Directory of Open Access Journals (Sweden)

    Jitandrakumar R. Patel

    2017-10-01

    Full Text Available Infants born premature are at increased risk for development of bronchopulmonary dysplasia (BPD, pulmonary hypertension (PH, and ultimately right ventricular (RV dysfunction, which together carry a high risk of neonatal mortality. However, the role alveolar simplification and abnormal pulmonary microvascular development in BPD affects RV contractile properties is unknown. We used a rat model of BPD to examine the effect of hyperoxia-induced PH on RV contractile properties. We measured in vivo RV pressure as well as passive force, maximum Ca2+ activated force, calcium sensitivity of force (pCa50 and rate of force redevelopment (ktr in RV skinned trabeculae isolated from hearts of 21-and 35-day old rats pre-exposed to 21% oxygen (normoxia or 85% oxygen (hyperoxia for 14 days after birth. Systolic and diastolic RV pressure were significantly higher at day 21 in hyperoxia exposed rats compared to normoxia control rats, but normalized by 35 days of age. Passive force, maximum Ca2+ activated force, and calcium sensitivity of force were elevated and cross-bridge cycling kinetics depressed in 21-day old hyperoxic trabeculae, whereas no differences between normoxic and hyperoxic trabeculae were seen at 35 days. Myofibrillar protein analysis revealed that 21-day old hyperoxic trabeculae had increased levels of beta-myosin heavy chain (β-MHC, atrial myosin light chain 1 (aMLC1; often referred to as essential light chain, and slow skeletal troponin I (ssTnI compared to age matched normoxic trabeculae. On the other hand, 35-day old normoxic and hyperoxic trabeculae expressed similar level of α- and β-MHC, ventricular MLC1 and predominantly cTnI. These results suggest that neonatal exposure to hyperoxia increases RV afterload and affect both the steady state and dynamic contractile properties of the RV, likely as a result of hyperoxia-induced expression of β-MHC, delayed transition of slow skeletal TnI to cardiac TnI, and expression of atrial MLC1. These

  12. American Brachytherapy Society recommendations for reporting morbidity after prostate brachytherapy

    International Nuclear Information System (INIS)

    Nag, Subir; Ellis, Rodney J.; Merrick, Gregory S.; Bahnson, Robert; Wallner, Kent; Stock, Richard

    2002-01-01

    Purpose: To standardize the reporting of brachytherapy-related prostate morbidity to guide ongoing clinical practice and future investigations. Methods: Members of the American Brachytherapy Society (ABS) with expertise in prostate brachytherapy performed a literature review and, guided by their clinical experience, formulated specific recommendations for reporting on morbidity related to prostate brachytherapy. Results: The ABS recommends using validated, patient-administered health-related quality-of-life instruments for the determination of baseline and follow-up data regarding bowel, urinary, and sexual function. Both actuarial and crude incidences should be reported, along with the temporal resolution of specific complications, and correlated with the doses to the normal tissues. The International Prostate Symptom Score is recommended to assess urinary morbidity, and any dysuria, gross hematuria, urinary retention, incontinence, or medication use should be quantified. Likewise, the ''Sexual Health Inventory for Men,'' which includes the specific erectile questions of the International Index of Erectile Function, is the preferred instrument for reporting sexual function, and the loss of sexual desire, incidence of hematospermia, painful orgasm (orgasmalgia), altered orgasm intensity, decreased ejaculatory volume, use of erectile aids, and use of hormones for androgen deprivation should be quantified. The ABS recommends adoption of the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer acute and late radiation morbidity scoring scheme for reporting rectal morbidity and noting the incidence of rectal steroid, laser, or antidiarrheal use. Conclusion: It is important to focus on health-related quality-of-life issues in the treatment of prostate cancer, because the control rates are very similar between appropriate treatment modalities. The ABS recommends using the International Prostate Symptom Score, International Index of

  13. Implementation of 3D-virtual brachytherapy in the management of breast cancer: a description of a new method of interstitial brachytherapy

    International Nuclear Information System (INIS)

    Vicini, Frank A.; Jaffray, David A.; Horwitz, Eric M.; Edmundson, Gregory K.; DeBiose, David A.; Kini, Vijay R.; Martinez, Alvaro A.

    1998-01-01

    preoperatively. Results: Intraoperative ultrasound was used to check the real-time position of the afterloading needles in reference to the chest wall and posterior border of the target volume. No adjustment of needles was required in any of the 11 patients. Assessment of target volume coverage between the virtual implant and the actual CT image of the implant showed excellent agreement. In each case, all target volume boundaries specified by the physician were adequately covered. The total number of implant planes, intertemplate separation, and template orientation were identical between the virtual and real implant. Conclusion: We conclude that 3D virtual brachytherapy may offer an improved technique for accurately performing interstitial implants of the breast with a closed lumpectomy cavity in selected patients. Although preliminary results show excellent coverage of the desired target volume, additional patients will be required to establish the reproducibility of this technique and its practical limitations

  14. Physical aspects of endovascular brachytherapy

    International Nuclear Information System (INIS)

    Kirisits, C.

    2001-11-01

    Restenosis is severely limiting the outcome of vascular interventions. In several clinical trials endovascular brachytherapy has shown to reduce the restenosis rate. Local radiotherapy to the injured vessel wall is a promising new type of treatment in order to inhibit a complex wound healing process resulting in cell proliferation and re-obstruction of the treated vessel. Treatment planning has to be based on the dose distribution in the vicinity of the sources used. Source strength was determined in terms of air kerma rate for gamma nuclides (Iridium-192) and absorbed dose to water at reference distance of 2 mm for beta nuclides (Strontium-90/Yttrium-90, Phosphor-32), respectively. Radial dose profiles and the Reference Isodose Length (RIL) were determined using the EGSnrc code and GafChromic film. Good agreement was found between both methods. In order to treat the entire clinical target length, the (RIL) is an essential value during treatment planning. Examples are described for different levels of treatment planing including recommendations for optimal choice and positioning of the radioactive devices inside the artery. IVUS based treatment planning is illustrated with superposition of isodoses on cross-sectional images. A calculation model for radioactive stents is presented in order to determine dose volume histograms in a retrospective analysis. Radiation protection issues for endovascular brachytherapy are discussed in detail. Personal dose for the involved personnel is estimated based on calculations and measurements. Beta ray dosimetry is performed with suitable detectors. In order to estimate the exposure to the patient the dose to organs at risk is calculated and compared to the dose from angiography. There is an additional radiation exposure to patients and personnel caused by endovascular brachytherapy, but the values are much smaller than those caused by diagnostic angiography. (author)

  15. Performance profiling for brachytherapy applications

    Science.gov (United States)

    Choi, Wonqook; Cho, Kihyeon; Yeo, Insung

    2018-05-01

    In many physics applications, a significant amount of software (e.g. R, ROOT and Geant4) is developed on novel computing architectures, and much effort is expended to ensure the software is efficient in terms of central processing unit (CPU) time and memory usage. Profiling tools are used during the evaluation process to evaluate the efficiency; however, few such tools are able to accommodate low-energy physics regions. To address this limitation, we developed a low-energy physics profiling system in Geant4 to profile the CPU time and memory of software applications in brachytherapy applications. This paper describes and evaluates specific models that are applied to brachytherapy applications in Geant4, such as QGSP_BIC_LIV, QGSP_BIC_EMZ, and QGSP_BIC_EMY. The physics range in this tool allows it to be used to generate low energy profiles in brachytherapy applications. This was a limitation in previous studies, which caused us to develop a new profiling tool that supports profiling in the MeV range, in contrast to the TeV range that is supported by existing high-energy profiling tools. In order to easily compare the profiling results between low-energy and high-energy modes, we employed the same software architecture as that in the SimpliCarlo tool developed at the Fermilab National Accelerator Laboratory (FNAL) for the Large Hadron Collider (LHC). The results show that the newly developed profiling system for low-energy physics (less than MeV) complements the current profiling system used for high-energy physics (greater than TeV) applications.

  16. Postoperative vaginal irradiation by a high dose-rate afterloading technique in endometrial carcinoma stage I

    International Nuclear Information System (INIS)

    Sorbe, B.; Smeds, A.C.

    1989-01-01

    A high dose-rate (cobalt-60) afterloading technique was used for postoperative vaginal irradiation in a series of 404 women with endometrial carcinoma stage I. The total recurrence rate was 3.7% with 0.7% vaginal lesions. The crude 5-year survival rate for the complete series was 91.8% compared to 13.3% for those with recurrences. Depth of myometrical infiltration (>1/3 of the uterine wall) and nuclear grade were the most important prognostic factors. Clinically significant late radiation reactions (bladder and/or rectum) were recorded in 6.9%. The absorbed dose per fraction and the size of the treatment volume were significantly related to the occurrence of both early and late radiation reactions. Vaginal shortening was closely related to the dose per fraction, length of the referce isodose and the applicator diameter. The shape of the vaginal applicator versus the isodose contours and the importance of the source train geometry and relative activity for absorbed dose inhomogeneitis within the treatment volume are discussed. Cumulative radiation effect (CRE) and linear-quadratic (LQ) calculations have been performed and related to tissue reactions within the target volume and in the risk organs. An alpha-beta quotient of 8.8 Gy for vaginal shrinkage effect and 2.0 Gy for late rectal complications are suggested on the basis of calculations using a maximum likelihood method for quantal radiation data. (orig.)

  17. Postoperative vaginal irradiation with high dose rate afterloading technique in endometrial carcinoma stage I

    International Nuclear Information System (INIS)

    Sorbe, B.G.; Smeds, A.C.

    1990-01-01

    A high dose rate ( 60 Co) afterloading technique was used for postoperative prophylactic vaginal irradiation in a series of 404 women with endometrial carcinoma Stage I. The total recurrence rate was 3.7% with 0.7% vaginal deposits. The crude 5-year survival rate for the complete series was 91.8% compared to 13.3% for those with recurrences. Depth of myometrial infiltration (greater than 1/3 of the uterine wall) and nuclear grade were the most important prognostic factors. Clinically significant late radiation reactions (bladder and/or rectum) were recorded in 6.9%. Dose per fraction and the size of the target volume were highly significantly related to the occurrence of both early and late radiation reactions. Vaginal shortening is closely related to the dose per fraction, length of the reference isodose, and the applicator diameter. The shape of the vaginal applicator versus the isodoses and the importance of the source train geometry and relative activity for dose gradient inhomogeneities within the target volume are discussed. Cumulative radiation effect (CRE) and linear-quadratic (LQ) calculations have been performed and related to tissue reactions within the target volume and in the risk organs. An alpha-beta quotient of 8.8 for vaginal shrinkage effect and 2.0 for late rectal complications are suggested on the basis of calculations using a maximum likelihood method for quantal radiation data

  18. Intracavitary irradiation of prostatic carcinoma by a high dose-rate afterloading technique

    Energy Technology Data Exchange (ETDEWEB)

    Odelberg-Johnson, O.; Underskog, I.; Johansson, J.E.; Bernshaw, D.; Sorbe, B.; Persson, J.E. (Oerebro Medical Center Hospital (Sweden). Dept. of Oncology Oerebro Medical Center Hospital (Sweden). Dept. of Urology Oerebro Medical Center Hospital (Sweden). Dept. of Gynecologic Oncology Oerebro Medical Center Hospital (Sweden). Dept. of Radiation Physics)

    1991-01-01

    A high dose-rate ({sup 60}Co) afterloading technique was evaluated in a series of 73 patients with prostatic carcinoma stages I-IV. The intraurethral irradiation was combined with external pelvic radiotherapy. A minimum total dose of 78 Gy was delivered to the target volume. In a subgroup of patients extramustine (Estracyt) was given as adjuvant chemohormonal therapy during irradiation. The median follow-up for the whole group was 63 months. The crude 5-year survival rate was 60% and the corrected survival rate 90%. Survival was related to the tumor grade. Local pelvic recurrences were recorded in 17.8%. 'Viable cells' in posttherapy aspiration biopsy were not associated with tumor recurrences or survival. Four patients (5%) had grade 3 late radiation reactions with urethral structure or bladder fibrosis. Urinary tract infections and prior transurethral resections were not associated with a higher frequency of reactions. Concurrent estramustine therapy seemed to increase the frequency of both acute and chronic radiation reactions. Local control, recurrence, and survival were not affected by chemohormonal therapy. The use of tomography, magnetic resonance, and ultrasound as aids to computerized dosimetry may improve local dose distribution and reduce the irradiated volume. (orig.).

  19. Functional reserve of the ischemic left ventricle with ventricular aneurysm to afterload stress

    International Nuclear Information System (INIS)

    Tsuiki, Kai; Kobayashi, Tadashi; Hayasaka, Makio

    1985-01-01

    The response of left ventricular function to afterload stress was assessed using DSA for eight patients with old anterior myocardial infarction and ventricular aneurysm including that of the anterior wall. After initial DSA in the basal state, methoxamine was infused intravenously (1 to 2 mg/min). When aortic systolic blood pressure increased by 30 to 50 mmHg, a second DSA was performed for each patient. Left ventricular volumes and ejection fractions were calculated by the area-length method, and regional wall motion was assessed by the visual method according to the AHA classification and the curvature radius of the apical ventricular aneurysm was calculated. Methoxamine induced neither acute heart failure nor angina pectoris in the present series. The heart rates decreased, and there were a significant increase in end-systolic volumes (p ES ). However, ΔESV and ΔR ES did not correlate; ΔR ES was much greater in two patients, who were relatively old. Their aneurysms were circumscribed within the left ventricular anterior wall, their ejection fractions were relatively increased; and their onsets of acute myocardial infarction were relatively recent. (J.P.N.)

  20. Guidelines for comprehensive quality assurance in brachytherapy

    International Nuclear Information System (INIS)

    Goldson, A.L.; Nibhanupudy, J.R.

    1984-01-01

    Brachytherapy treatment techniques can provide significant improvement in local control and overall survival, but only when quality assurance can be guaranteed. To establish brachytherapy quality assurance, basic requirements for three predetermined subdivisions of clinical institutions will be forwarded. These are: (1) centers having minimum requirements to provide brachytherapy, (2) intermediate centers such as regional or community hospitals, and (3) optimal centers such as university hospital and cancer centers. This presentation will highlight personnel needs, equipment requirements, academic activities, clinical experience with these systems and proposed quality assurance guidelines

  1. 10 CFR 35.690 - Training for use of remote afterloader units, teletherapy units, and gamma stereotactic...

    Science.gov (United States)

    2010-01-01

    ... radiation safety, radionuclide handling, treatment planning, quality assurance, and clinical use of... medical unit that includes— (i) 200 hours of classroom and laboratory training in the following areas— (A... administrative controls to prevent a medical event involving the use of byproduct material; (D) Implementing...

  2. Is there any advantage of CT based 3-dimensional conformal planning over conventional orthogonal x-ray based planning in HDR brachytherapy in breast cancer

    International Nuclear Information System (INIS)

    Biswal, B.M.; Idris, N.R.; Zakaria, A.B.; Khairul, N.

    2003-01-01

    The conventional brachytherapy dose calculation is based on a particular brachytherapy rule or individual dosimetry based on the reconstruction of the sources from the orthogonal films. In the recent years many centers are using CT based 3D conformal brachytherapy in order to improve the dosimetric outcome of a given plan. Here we would like to present our experience on the use of both techniques to deliver HDR interstitial brachytherapy as boost in early breast cancer. From January 2001 to January 2003, we treated 4 breast cancer patients using conventional orthogonal x-rays and CT scan in 3 cases for the treatment plan. All patients received an external beam radiotherapy dose of 46 Gy in 23 fractions over 4.5 weeks to the whole breast using 6 MV photon beam. Subsequently the primary lesion was supplimented with HDR brachytherapy to a dose of 2.5 Gy BID for 3 consecutive days using a (192)Ir microSelectronHDR. The dose prescription was individualized to encompass the tumor volume with a 10 mm margin. The differences of the dosimetric outcome were compared. All patients completed above schedule of radiotherapy. The primary was implanted with single plane in 3 patients and multiplane implant in 4 patients. Orthogonal x-ray based localization was performed in 4 patients and CT scan based localization in 3 cases. Three patients were implanted single plane and 4 patients with multiplane implants with a median catheter number of 9 (range 6-14). The 3D conformal dose optimization was performed using Nucletron planning system (Plato). The mean 100% and 150% isodose volume was 67.3 cm 3 and 31.25cm 3 respectively. The identification of primary tumor volume, organ at risk, and identification of afterloading catheters were superior in CT based plan than conventional planning. CT scan based 3D conformal brachytherapy planning give better identification of tumor volume and its curvature, decrease the time to identify the sources and evaluate the radiation dose to organs at

  3. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Concomitant chemoradiotherapy with high dose rate brachytherapy as a definitive treatment modality for locally advanced cervical cancer. T Refaat, A Elsaid, N Lotfy, K Kiel, W Small Jr, P Nickers, E Lartigau ...

  4. Comprehensive brachytherapy physical and clinical aspects

    CERN Document Server

    Baltas, Dimos; Meigooni, Ali S; Hoskin, Peter J

    2013-01-01

    Modern brachytherapy is one of the most important oncological treatment modalities requiring an integrated approach that utilizes new technologies, advanced clinical imaging facilities, and a thorough understanding of the radiobiological effects on different tissues, the principles of physics, dosimetry techniques and protocols, and clinical expertise. A complete overview of the field, Comprehensive Brachytherapy: Physical and Clinical Aspects is a landmark publication, presenting a detailed account of the underlying physics, design, and implementation of the techniques, along with practical guidance for practitioners. Bridging the gap between research and application, this single source brings together the technological basis, radiation dosimetry, quality assurance, and fundamentals of brachytherapy. In addition, it presents discussion of the most recent clinical practice in brachytherapy including prostate, gynecology, breast, and other clinical treatment sites. Along with exploring new clinical protocols, ...

  5. Evolution of brachytherapy for prostate carcinoma

    International Nuclear Information System (INIS)

    Qin Lan

    2005-01-01

    Brachytherapy is one of the most main management to prostate carcinoma. This method has been rapidly accepted in clinical application since it is a convenient, little-traumatic, and outpatient therapy. With the development of techniques of production of radio-seeds, imaging modality and three-dimensional radiotherapy plan system, brachytherapy has been made a virtually progress in improving curative-effect and reducing damage to surrounding normal tissue. (authors)

  6. Monte Carlo model for a prototype CT-compatible, anatomically adaptive, shielded intracavitary brachytherapy applicator for the treatment of cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Price, Michael J.; Gifford, Kent A.; Horton, John L. Jr.; Eifel, Patricia J.; Gillin, Michael T.; Lawyer, Ann A.; Mourtada, Firas [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1220 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, University of Texas-Houston, 6767 Bertner Avenue, Houston, Texas 77030 (United States); Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1220 Holcombe Boulevard, Houston, Texas 77030 (United States); Division of Radiation Oncology, University of Texas M. D. Anderson Cancer Center, 1220 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, University of Texas-Houston, 6767 Bertner Avenue, Houston, Texas 77030 (United States); Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1220 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, University of Texas-Houston, 6767 Bertner Avenue, Houston, Texas 77030 (United States); Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1220 Holcombe Boulevard, Houston, Texas 77030 (United States); Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1220 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, University of Texas-Houston, 6767 Bertner Avenue, Houston, Texas 77030 (United States)

    2009-09-15

    Purpose: Current, clinically applicable intracavitary brachytherapy applicators that utilize shielded ovoids contain a pair of tungsten-alloy shields which serve to reduce dose delivered to the rectum and bladder during source afterloading. After applicator insertion, these fixed shields are not necessarily positioned to provide optimal shielding of these critical structures due to variations in patient anatomies. The authors present a dosimetric evaluation of a novel prototype intracavitary brachytherapy ovoid [anatomically adaptive applicator (A{sup 3})], featuring a single shield whose position can be adjusted with two degrees of freedom: Rotation about and translation along the long axis of the ovoid. Methods: The dosimetry of the device for a HDR {sup 192}Ir was characterized using radiochromic film measurements for various shield orientations. A MCNPX Monte Carlo model was developed of the prototype ovoid and integrated with a previously validated model of a v2 mHDR {sup 192}Ir source (Nucletron Co.). The model was validated for three distinct shield orientations using film measurements. Results: For the most complex case, 91% of the absolute simulated and measured dose points agreed within 2% or 2 mm and 96% agreed within 10% or 2 mm. Conclusions: Validation of the Monte Carlo model facilitates future investigations into any dosimetric advantages the use of the A{sup 3} may have over the current state of art with respect to optimization and customization of dose delivery as a function of patient anatomical geometries.

  7. Monte Carlo model for a prototype CT-compatible, anatomically adaptive, shielded intracavitary brachytherapy applicator for the treatment of cervical cancer

    International Nuclear Information System (INIS)

    Price, Michael J.; Gifford, Kent A.; Horton, John L. Jr.; Eifel, Patricia J.; Gillin, Michael T.; Lawyer, Ann A.; Mourtada, Firas

    2009-01-01

    Purpose: Current, clinically applicable intracavitary brachytherapy applicators that utilize shielded ovoids contain a pair of tungsten-alloy shields which serve to reduce dose delivered to the rectum and bladder during source afterloading. After applicator insertion, these fixed shields are not necessarily positioned to provide optimal shielding of these critical structures due to variations in patient anatomies. The authors present a dosimetric evaluation of a novel prototype intracavitary brachytherapy ovoid [anatomically adaptive applicator (A 3 )], featuring a single shield whose position can be adjusted with two degrees of freedom: Rotation about and translation along the long axis of the ovoid. Methods: The dosimetry of the device for a HDR 192 Ir was characterized using radiochromic film measurements for various shield orientations. A MCNPX Monte Carlo model was developed of the prototype ovoid and integrated with a previously validated model of a v2 mHDR 192 Ir source (Nucletron Co.). The model was validated for three distinct shield orientations using film measurements. Results: For the most complex case, 91% of the absolute simulated and measured dose points agreed within 2% or 2 mm and 96% agreed within 10% or 2 mm. Conclusions: Validation of the Monte Carlo model facilitates future investigations into any dosimetric advantages the use of the A 3 may have over the current state of art with respect to optimization and customization of dose delivery as a function of patient anatomical geometries.

  8. Long duration mild temperature hyperthermia and brachytherapy.

    Science.gov (United States)

    Armour, E P; Raaphorst, G P

    2004-03-01

    Combining long duration mild temperature hyperthermia (LDMH) and low dose-rate (LDR) brachytherapy to enhance therapeutic killing of cancer cells was proposed many years ago. The cellular and tumour research that supports this hypothesis is presented in this review. Research describing LDMH interaction with pulsed brachytherapy and high dose-rate brachytherapy using clinically relevant parameters are compared with LDMH/LDR brachytherapy. The mechanism by which LDMH sensitizes LDR has been established as the inhibition of sublethal damage repair. The molecular mechanisms have been shown to involve DNA repair enzymes, but the exact nature of these processes is still under investigation. The relative differences between LDMH interactions with human and rodent cells are presented to help in the understanding of possible roles of LDMH in clinical application. The role of LDMH in modifying tumour blood flow and its possible role in LDR sensitization of tumours is also presented. The positive aspects of LDMH-brachytherapy for clinical application are sixfold; (1) the thermal goals (temperature, time and volume) are achievable with currently available technology, (2) the hyperthermia by itself has no detectable toxic effects, (3) thermotolerance appears to play a minor if any role in radiation sensitization, (4) TER of around 2 can be expected, (5) hypoxic fraction may be decreased due to blood flow modification and (6) simultaneous chemotherapy may also be sensitized. Combined LDMH and brachytherapy is a cancer therapy that has established biological rationale and sufficient technical and clinical advancements to be appropriately applied. This modality is ripe for clinical testing.

  9. The American Brachytherapy Society recommendations for low-dose-rate brachytherapy for carcinoma of the cervix

    International Nuclear Information System (INIS)

    Nag, Subir; Chao, Clifford; Erickson, Beth; Fowler, Jeffery; Gupta, Nilendu; Martinez, Alvaro; Thomadsen, Bruce

    2002-01-01

    Purpose: This report presents guidelines for using low-dose-rate (LDR) brachytherapy in the management of patients with cervical cancer. Methods: Members of the American Brachytherapy Society (ABS) with expertise in LDR brachytherapy for cervical cancer performed a literature review, supplemented by their clinical experience, to formulate guidelines for LDR brachytherapy of cervical cancer. Results: The ABS strongly recommends that radiation treatment for cervical carcinoma (with or without chemotherapy) should include brachytherapy as a component. Precise applicator placement is essential for improved local control and reduced morbidity. The outcome of brachytherapy depends, in part, on the skill of the brachytherapist. Doses given by external beam radiotherapy and brachytherapy depend upon the initial volume of disease, the ability to displace the bladder and rectum, the degree of tumor regression during pelvic irradiation, and institutional practice. The ABS recognizes that intracavitary brachytherapy is the standard technique for brachytherapy for cervical carcinoma. Interstitial brachytherapy should be considered for patients with disease that cannot be optimally encompassed by intracavitary brachytherapy. The ABS recommends completion of treatment within 8 weeks, when possible. Prolonging total treatment duration can adversely affect local control and survival. Recommendations are made for definitive and postoperative therapy after hysterectomy. Although recognizing that many efficacious LDR dose schedules exist, the ABS presents suggested dose and fractionation schemes for combining external beam radiotherapy with LDR brachytherapy for each stage of disease. The dose prescription point (point A) is defined for intracavitary insertions. Dose rates of 0.50 to 0.65 Gy/h are suggested for intracavitary brachytherapy. Dose rates of 0.50 to 0.70 Gy/h to the periphery of the implant are suggested for interstitial implant. Use of differential source activity or

  10. Acute vasculitis after endovascular brachytherapy

    International Nuclear Information System (INIS)

    Fajardo L-G, Luis F.; Prionas, Stavros D.; Kaluza, Grzegorz L.; Raizner, Albert E.

    2002-01-01

    Purpose: Angioplasty effectively relieves coronary artery stenosis but is often followed by restenosis. Endovascular radiation (β or γ) at the time of angioplasty prevents restenosis in a large proportion of vessels in swine (short term) and humans (short and long term). Little information is available about the effects of this radiation exposure beyond the wall of the coronary arteries. Methods and Materials: Samples were obtained from 76 minipigs in the course of several experiments designed to evaluate endovascular brachytherapy: 76 of 114 coronary arteries and 6 of 12 iliac arteries were exposed to endovascular radiation from 32 P sources (35 Gy at 0.5 mm from the intima). Two-thirds of the vessels had angioplasty or stenting. The vessels were systematically examined either at 28 days or at 6 months after radiation. Results: We found an unexpected lesion: acute necrotizing vasculitis in arterioles located ≤2.05 mm from the target artery. It was characterized by fibrinoid necrosis of the wall, often associated with lymphocytic exudates or thrombosis. Based on the review of perpendicular sections of tissue samples, the arterioles had received between 6 and 40 Gy. This arteriolar vasculitis occurred at 28 days in samples from 51% of irradiated coronary arteries and 100% of irradiated iliac arteries. By 6 months, the incidence of acute vasculitis decreased to 24% around the coronary arteries. However, at that time, healing vasculitis was evident, often with luminal narrowing, in 46% of samples. Vasculitis was not seen in any of 44 samples from unirradiated vessels (0%) and had no relation to angioplasty, stenting, or their sequelae. This radiation-associated vasculitis in the swine resembles the localized lymphocytic vasculitis that we have reported in tissues of humans exposed to external radiation. On the other hand, it is quite different from the various types of systemic vasculitis that occur in nonirradiated humans. Conclusion: Endoarterial brachytherapy

  11. Two years experience with a computer-assisted monitoring and recording system used in gynecological afterloading therapy

    International Nuclear Information System (INIS)

    Kaulich, T.W.; Boedi, R.; Nuesslin, F.; Hirnle, P.

    1990-01-01

    A computer program running on a simple desk-calculator has been developed for monitoring and recording gynecological high-dose afterloading therapy. For treatment monitoring the multiple-probe AM6-system (PTW-Freiburg) is used which allows for dose measurements in the urinary bladder and the rectum. The probe signals are processed on line in order to indicate the actual dose at the measuring points. After completing the irradiation the treatment is documented. Performing fractionated treatment the measuring data are stored in the computer memory for calculating total accumulated dose. The above-described monitoring- and protocolling system has proven its usefulness during two years of clinical work. (orig.) [de

  12. Navigation system for interstitial brachytherapy

    International Nuclear Information System (INIS)

    Strassmann, G.; Kolotas, C.; Heyd, R.

    2000-01-01

    The purpose of the stud was to develop a computed tomography (CT) based electromagnetic navigation system for interstitial brachytherapy. This is especially designed for situations when needles have to be positioned adjacent to or within critical anatomical structures. In such instances interactive 3D visualisation of the needle positions is essential. The material consisted of a Polhemus electromagnetic 3D digitizer, a Pentium 200 MHz laptop and a voice recognition for continuous speech. In addition, we developed an external reference system constructed of Perspex which could be positioned above the tumour region and attached to the patient using a non-invasive fixation method. A specially designed needle holder and patient bed were also developed. Measurements were made on a series of phantoms in order to study the efficacy and accuracy of the navigation system. The mean navigation accuracy of positioning the 20.0 cm length metallic needles within the phantoms was in the range 2.0-4.1 mm with a maximum of 5.4 mm. This is an improvement on the accuracy of a CT-guided technique which was in the range 6.1-11.3 mm with a maximum of 19.4 mm. The mean reconstruction accuracy of the implant geometry was 3.2 mm within a non-ferromagnetic environment. We found that although the needles were metallic this did not have a significant influence. We also found for our experimental setups that the CT table and operation table non-ferromagnetic parts had no significant influence on the navigation accuracy. This navigation system will be a very useful clinical tool for interstitial brachytherapy applications, particularly when critical structures have to be avoided. It also should provide a significant improvement on our existing technique

  13. 10 CFR 35.2406 - Records of brachytherapy source accountability.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of brachytherapy source accountability. 35.2406... Records of brachytherapy source accountability. (a) A licensee shall maintain a record of brachytherapy source accountability required by § 35.406 for 3 years. (b) For temporary implants, the record must...

  14. 10 CFR 35.406 - Brachytherapy sources accountability.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Brachytherapy sources accountability. 35.406 Section 35....406 Brachytherapy sources accountability. (a) A licensee shall maintain accountability at all times... area. (c) A licensee shall maintain a record of the brachytherapy source accountability in accordance...

  15. Methodology, results and experience of independent brachytherapy plan verifications based on DICOM standard; Implementacion, resultados y experiencia de una verificacion independiente de tratamientos de braquiterapia basada en el estandar DICOM

    Energy Technology Data Exchange (ETDEWEB)

    Ferrando Sanchez, A.; Pardo Perez, E.; Castro Novals, J.; Casa de Julian, M. A. de la; Cabello Murillo, E.; Diaz Fuentes, R.; Molina Lopez, M. Y.

    2013-09-01

    The use of a high dose rate source together with an afterloading treatment delivery in brachytherapy plans allows for dose modulation minimizing dose to staff. An independent verification of the exported data to the treatment station is required by local regulations (being also a widely accepted recommendation on the international literature). We have developed a methodology under home brew code to import DICOM treatment data onto an Excel spreadsheet that is able to calculate dose on given reference points using the TG-43 formalism of the AAPM3-5. It employs analytic fits of anisotropy factor and radial dose function for different sources. The end point implementations we present here allow merging in one step an independent verification and a treatment printout. The use of DICOM standard makes our code versatile and provides greater compatibility with respect to current treatment planning systems. (Author)

  16. SU-G-201-07: Dosimetric Verification of a 3D Printed HDR Skin Brachytherapy Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, K; Stanley, D; Eng, T; Kirby, N; Gutierrez, A; Stathakis, S; Papanikolaou, N [University of Texas HSC SA, San Antonio, TX (United States); Baumgarten, A; Pelletier, C; Jung, J; Feng, Y; Huang, Z; Ju, A [East Carolina University, Greenville, NC (United States); Corbett, M [Greenville Health System, Greenville, SC (United States)

    2016-06-15

    Purpose: The use of radiation as a treatment modality for skin cancer has increased significantly over the last decade with standardized applicators. Utilizing 3D printing, the ability to make applicators specifically designed for each patient’s anatomy has become economically feasible. With this in mind it was the aim of this study to determine the dosimetric accuracy of a 3-D printed HDR brachytherapy applicator for the skin. Methods: A CT reference image was used to generate a custom applicator based on an anthropomorphic head and neck phantom. To create the applicator a 1cm expansion anteriorly with 0.5cmX0.5cm trenches on the outer surface that were spaced 1cm sup-inf to accommodate standard 6F flexible catheters. The applicator was printed using PLA material using a printrbot simple printer. A treatment plan optimized to deliver a clinically representative volume was created in Oncentra and delivered with a nucletron afterloader. Measurements were made using TLDs and EBT3 gafchromic film that were placed between the applicator and the phantom’s forehead. An additional piece of film was also used to qualitatively asses the dose distribution in the transverse plane. Using a standard vaginal cylinder and bolus, a standardized curve correlating TLD and film exposure-to-radiation dose was established by irradiating film to known doses (200,500,700 cGy) at a 3.5 cm radius distance. Results: Evaluated TLDs showed the absolute dose delivered to the skin surface using the 3-D printed bolus was 615cGy±6%, with a mean predicted TPS value in the measured area of 617.5±7%. Additionally, planar dose distributions had good qualitative agreement with calculated TPS isodoses. Conclusion: This work demonstrates patient specific 3-D printed HDR brachytherapy applicators for skin cancer treatments are practical and accurate in TPS calculations but additional measurements are needed to verify additional sites and dose at depth.

  17. Effect and toxicity of endoluminal high-dose-rate (HDR) brachytherapy in centrally located tumors of the upper respiratory tract

    International Nuclear Information System (INIS)

    Harms, W.; Wannenmacher, M.; Becker, H.; Herth, F.; Fritz, P.

    2000-01-01

    Aim: To assess effect an toxicity of high-dose-rate afterloading (HDR) alone or in combination with external beam radiotherapy (EBRT) in centrally located tumors of the upper respiratory tract. Patients and Methods: From 1987 to 1996, 55 patients were treated. Twenty-one patients (group A1: 17 non-small-cell lung cancer [NSCLC], A2: 4 metastases from other malignancies) were treated using HDR alone due to a relapse after external beam irradiation. In 34 previously untreated and inoperable patients (group B1: 27 NSCLC, B2: 7 metastases from other malignancies) HDR was given as a boost after EBRT (30 to 60 Gy, median 50). HDR was carried out with a 192 Ir source (370 GBq). The brachytherapy dose (group A: 5 to 27 Gy, median 20; B: 10 to 20 Gy, median 15) was prescribed to 1 cm distance from the source axis. A distanciable applicator was used in 39/55 patients. Results: In group A1, a response rate (CR, PR) of 53% (group B1: 77%) was reached. The median survival (Kaplan-Meier) was 5 months in group A1 (B1: 20 months). The 1-, 3- and 5-year local progression free survival rates (Kaplan-Meier) were 66% (15%), 52% (0%), and 37% (0%) in group B1 (group A1). Prognostic favorable factors in group B1 were a tumor diameter 70. Grade-1 or 2 toxicity (RTOG/EORTC) occurred in 0% in group A and in 6% in group B. We observed no Grad-3 or 4 toxicity. Complications caused by persistent or progressive local disease occurred in 3 patients in goup A (fatal hemorrhage, tracheomediastinal fistula, hemoptysis) and in 2 patients in group B (fatal hemorrhage, hemoptysis). Conclusions: HDR brachytherapy is an effective treatment with moderate side effects. In combination with external beam irradiation long-term remissions can be reached in one third of the patients. (orig.) [de

  18. Quality assurance in breast cancer brachytherapy: geographic miss in the interstitial boost treatment of the tumor bed.

    Science.gov (United States)

    Sedlmayer, F; Rahim, H B; Kogelnik, H D; Menzel, C; Merz, F; Deutschmann, H; Kranzinger, M

    1996-03-15

    To assess the role of geographic misses in the interstitial boost treatment of breast cancer patients and to evaluate methods of optimizing breast implants in design, performance, and dosimetry. During lumpectomy, the tumor excision sites of 89 patients were marked by five hemoclips. Postoperative radiographs demonstrated the clips' positions with respect to the extension of the surgical cavity, which was demarcated by air and hematoseroma. Twenty-seven selected patients received interstitial boosts to the tumor bed. The implant was first designed according to the clinical assumptions of the tumor bed's topography and then compared with the radiological findings. Prior to brachytherapy, the planning of the implant's dimension and the needle guidance was performed under simulator control. Dose distributions were first calculated following the Paris System and then electively optimized for the target volume by changing source positions and dwell times. Compared to clinical estimations, the radiological determination of the tumor bed's location revealed an overall potential of topographic errors of 51.8% (14 out of 27 patients), rising up to 78.5% in patients with large adipose breasts (11 out of 13 patients). This observation was due to a high mobility of the tissue, leading to varying tumor site projections at the time of mammography, surgery, and brachytherapy. In all patients, the presimulation of the implant resulted in an adequate coverage of the target volume. In 17 of the 27 treated patients, dose distributions were modified to achieve a higher dose delivery in zones where a higher residual tumor load was expected (boost-in-boost). Breast implants have a high potential of geographic misses that can be avoided by intraoperative clip demarcation. The delineation of the tumor bed allows for dose reports actually referring to the target volume and not to the implant system to be obtained. In addition, modern afterloading techniques offer possibilities of

  19. SU-G-201-07: Dosimetric Verification of a 3D Printed HDR Skin Brachytherapy Applicator

    International Nuclear Information System (INIS)

    Rasmussen, K; Stanley, D; Eng, T; Kirby, N; Gutierrez, A; Stathakis, S; Papanikolaou, N; Baumgarten, A; Pelletier, C; Jung, J; Feng, Y; Huang, Z; Ju, A; Corbett, M

    2016-01-01

    Purpose: The use of radiation as a treatment modality for skin cancer has increased significantly over the last decade with standardized applicators. Utilizing 3D printing, the ability to make applicators specifically designed for each patient’s anatomy has become economically feasible. With this in mind it was the aim of this study to determine the dosimetric accuracy of a 3-D printed HDR brachytherapy applicator for the skin. Methods: A CT reference image was used to generate a custom applicator based on an anthropomorphic head and neck phantom. To create the applicator a 1cm expansion anteriorly with 0.5cmX0.5cm trenches on the outer surface that were spaced 1cm sup-inf to accommodate standard 6F flexible catheters. The applicator was printed using PLA material using a printrbot simple printer. A treatment plan optimized to deliver a clinically representative volume was created in Oncentra and delivered with a nucletron afterloader. Measurements were made using TLDs and EBT3 gafchromic film that were placed between the applicator and the phantom’s forehead. An additional piece of film was also used to qualitatively asses the dose distribution in the transverse plane. Using a standard vaginal cylinder and bolus, a standardized curve correlating TLD and film exposure-to-radiation dose was established by irradiating film to known doses (200,500,700 cGy) at a 3.5 cm radius distance. Results: Evaluated TLDs showed the absolute dose delivered to the skin surface using the 3-D printed bolus was 615cGy±6%, with a mean predicted TPS value in the measured area of 617.5±7%. Additionally, planar dose distributions had good qualitative agreement with calculated TPS isodoses. Conclusion: This work demonstrates patient specific 3-D printed HDR brachytherapy applicators for skin cancer treatments are practical and accurate in TPS calculations but additional measurements are needed to verify additional sites and dose at depth.

  20. Quality assurance in breast cancer brachytherapy: geographic miss in the interstitial boost treatment of the tumor bed

    International Nuclear Information System (INIS)

    Sedlmayer, Felix; Rahim, Hassan B. K.; Kogelnik, H. Dieter; Menzel, Christian; Merz, Florian; Deutschmann, Heinz; Kranzinger, Manfred

    1996-01-01

    Purpose: To assess the role of geographic misses in the interstitial boost treatment of breast cancer patients and to evaluate methods of optimizing breast implants in design, performance, and dosimetry. Methods and Materials: During lumpectomy, the tumor excision sites of 89 patients were marked by five hemoclips. Postoperative radiographs demonstrated the clips' positions with respect to the extension of the surgical cavity, which was demarcated by air and hematoseroma. Twenty-seven selected patients received interstitial boosts to the tumor bed. The implant was first designed according to the clinical assumptions of the tumor bed's topography and then compared with the radiological findings. Prior to brachytherapy, the planning of the implant's dimension and the needle guidance was performed under simulator control. Dose distributions were first calculated following the Paris System and then electively optimized for the target volume by changing source positions and dwell times. Results: Compared to clinical estimations, the radiological determination of the tumor bed's location revealed an overall potential of topographic errors of 51.8% (14 out of 27 patients), rising up to 78.5% in patients with large adipose breasts (11 out of 13 patients). This observation was due to a high mobility of the tissue, leading to varying tumor site projections at the time of mammography, surgery, and brachytherapy. In all patients, the presimulation of the implant resulted in an adequate coverage of the target volume. In 17 of the 27 treated patients, dose distributions were modified to achieve a higher dose delivery in zones where a higher residual tumor load was expected (boost-in-boost). Conclusion: Breast implants have a high potential of geographic misses that can be avoided by intraoperative clip demarcation. The delineation of the tumor bed allows for dose reports actually referring to the target volume and not to the implant system to be obtained. In addition, modern

  1. MO-AB-BRA-03: Development of Novel Real Time in Vivo EPID Treatment Verification for Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, G; Podesta, M [Department of Radiation Oncology (MAASTRO), GROW School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Reniers, B [Department of Radiation Oncology (MAASTRO), GROW School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Research Group NuTeC, CMK, Hasselt University, Agoralaan Gebouw H, Diepenbeek B-3590 (Belgium); Verhaegen, F [Department of Radiation Oncology (MAASTRO), GROW School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Medical Physics Unit, Department of Oncology, McGill University, Montreal, Quebec H3G 1A4 (Canada)

    2016-06-15

    Purpose: High Dose Rate (HDR) brachytherapy treatments are employed worldwide to treat a wide variety of cancers. However, in vivo dose verification remains a challenge with no commercial dosimetry system available to verify the treatment dose delivered to the patient. We propose a novel dosimetry system that couples an independent Monte Carlo (MC) simulation platform and an amorphous silicon Electronic Portal Imaging Device (EPID) to provide real time treatment verification. Methods: MC calculations predict the EPID response to the photon fluence emitted by the HDR source by simulating the patient, the source dwell positions and times, and treatment complexities such as tissue compositions/densities and different applicators. Simulated results are then compared against EPID measurements acquired with ∼0.14s time resolution which allows dose measurements for each dwell position. The EPID has been calibrated using an Ir-192 HDR source and experiments were performed using different phantoms, including tissue equivalent materials (PMMA, lung and bone). A source positioning accuracy of 0.2 mm, without including the afterloader uncertainty, was ensured using a robotic arm moving the source. Results: An EPID can acquire 3D Cartesian source positions and its response varies significantly due to differences in the material composition/density of the irradiated object, allowing detection of changes in patient geometry. The panel time resolution allows dose rate and dwell time measurements. Moreover, predicted EPID images obtained from clinical treatment plans provide anatomical information that can be related to the patient anatomy, mostly bone and air cavities, localizing the source inside of the patient using its anatomy as reference. Conclusion: Results obtained show the feasibility of the proposed dose verification system that is capable to verify all the brachytherapy treatment steps in real time providing data about treatment delivery quality and also applicator

  2. Calculation of integrated biological response in brachytherapy

    International Nuclear Information System (INIS)

    Dale, Roger G.; Coles, Ian P.; Deehan, Charles; O'Donoghue, Joseph A.

    1997-01-01

    Purpose: To present analytical methods for calculating or estimating the integrated biological response in brachytherapy applications, and which allow for the presence of dose gradients. Methods and Materials: The approach uses linear-quadratic (LQ) formulations to identify an equivalent biologically effective dose (BED eq ) which, if applied to a specified tissue volume, would produce the same biological effect as that achieved by a given brachytherapy application. For simple geometrical cases, BED multiplying factors have been derived which allow the equivalent BED for tumors to be estimated from a single BED value calculated at a dose reference point. For more complex brachytherapy applications a voxel-by-voxel determination of the equivalent BED will be more accurate. Equations are derived which when incorporated into brachytherapy software would facilitate such a process. Results: At both high and low dose rates, the BEDs calculated at the dose reference point are shown to be lower than the true values by an amount which depends primarily on the magnitude of the prescribed dose; the BED multiplying factors are higher for smaller prescribed doses. The multiplying factors are less dependent on the assumed radiobiological parameters. In most clinical applications involving multiple sources, particularly those in multiplanar arrays, the multiplying factors are likely to be smaller than those derived here for single sources. The overall suggestion is that the radiobiological consequences of dose gradients in well-designed brachytherapy treatments, although important, may be less significant than is sometimes supposed. The modeling exercise also demonstrates that the integrated biological effect associated with fractionated high-dose-rate (FHDR) brachytherapy will usually be different from that for an 'equivalent' continuous low-dose-rate (CLDR) regime. For practical FHDR regimes involving relatively small numbers of fractions, the integrated biological effect to

  3. ACPSEM brachytherapy working group recommendations for quality assurance in brachytherapy

    International Nuclear Information System (INIS)

    Dempsey, Claire; Smith, Ryan; Nyathi, Thulani; Ceylan, Abdurrahman; Howard, Lisa; Patel, Virendra; Dam, Ras; Haworth, Annette

    2013-01-01

    The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop recommendation papers for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intended to provide guidance for safe work practices and a suitable level of quality control without detailed work instructions. It is the responsibility of the medical physicist to ensure that locally available equipment and procedures are sufficiently sensitive to establish compliance to these recommendations. The recommendations are endorsed by the ROSG, have been subject to independent expert reviews and have also been approved by the ACPSEM Council. For the Australian audience, these recommendations should be read in conjunction with the Tripartite Radiation Oncology Practice Standards. This publication presents the recommendations of the ACPSEM Brachytherapy Working Group (BTWG) and has been developed in alignment with other international associations. However, these recommendations should be read in conjunction with relevant national, state or territory legislation and local requirements, which take precedence over the ACPSEM recommendation papers. It is hoped that the users of this and other ACPSEM recommendation papers will contribute to the development of future versions through the Radiation Oncology Specialty Group of the ACPSEM.

  4. Local anesthesia for prostate brachytherapy

    International Nuclear Information System (INIS)

    Wallner, Kent; Simpson, Colleen; Roof, James; Arthurs, Sandy; Korssjoen, Tammy; Sutlief, Steven

    1999-01-01

    Purpose: To demonstrate the technique and feasibility of prostate brachytherapy performed with local anesthesia only. Methods and Materials: A 5 by 5 cm patch of perineal skin and subcutaneous tissue is anesthetized by local infiltration of 10 cc of 1% lidocaine with epinephrine, using a 25-gauge 5/8-inch needle. Immediately following injection into the subcutaneous tissues, the deeper tissues, including the pelvic floor and prostate apex, are anesthetized by injecting 15 cc lidocaine solution with approximately 8 passes of a 20-gauge 1.0-inch needle. Following subcutaneous and peri-apical lidocaine injections, the patient is brought to the simulator suite and placed in leg stirrups. The transrectal ultrasound (TRUS) probe is positioned to reproduce the planning images and a 3.5- or 6.0-inch, 22-gauge spinal needle is inserted into the peripheral planned needle tracks, monitored by TRUS. When the tips of the needles reach the prostatic base, about 1 cc of lidocaine solution is injected in the intraprostatic track, as the needle is slowly withdrawn, for a total volume of 15 cc. The implants are done with a Mick Applicator, inserting and loading groups of two to four needles, so that a maximum of only about four needles are in the patient at any one time. During the implant procedure, an additional 1 cc of lidocaine solution is injected into one or more needle tracks if the patient experiences substantial discomfort. The total dose of lidocaine is generally limited to 500 mg (50 ml of 1% solution). Results: To date, we have implanted approximately 50 patients in our simulator suite, using local anesthesia. Patients' heart rate and diastolic blood pressure usually showed moderate changes, consistent with some discomfort. The time from first subcutaneous injection and completion of the source insertion ranged from 35 to 90 minutes. Serum lidocaine levels were below or at the low range of therapeutic. There has been only one instance of acute urinary retention in the

  5. High dose-rate brachytherapy for elderly patients with uterine cervical cancer

    International Nuclear Information System (INIS)

    Chen, Shang-Wen; Liang, Ji-An; Yang, Shih-Neng; Lin, Fang-Jen

    2003-01-01

    The need for radiotherapy (RT) in cancer treatment for the elderly patient is growing. The purpose of this study was to analyze the efficacy and complication rate for radiotherapy, using external-beam irradiation (EBRT) and high dose-rate intracavitary brachytherapy (HDRICB), for patients aged 70 years or older with carcinoma of the uterine cervix. From September 1992 to December 1997, 295 patients diagnosed with uterine cervical cancer completed RT at the Shin Kong Memorial Hospital and China Medical College Hospital. Two hundred and fifty-eight patients [International Federation of Gynecology and Obstetrics (FIGO) stage distribution: 35 Ib, 26 IIa, 122 IIb, 10 IIIa, 58 IIIb, 7 IVa] who had undergone at least two courses of HDRICB and a minimum of 3 years of follow-up, were evaluated. A retrospective analysis was conducted to compare the outcome of radiation therapy for the 179 patients under 70 years of age (younger group) and the 79 patients aged 70 years or older (older group). The RT consisted of EBRT followed by HDRICB. After a total EBRT dose of 40-45 Gy/20 in 25 fractions, irradiating the whole pelvis over 4-5 weeks, dosage for patients diagnosed as FIGO stage IIb-IVa bilateral parametrial disease was boosted to 54-58 Gy, with central shielding. HDRICB was administered at 1-week intervals using an Ir-192 remote after-loading technique. Ninety-nine patients (38.4%) received three fractions of HDRICB, while 156 patients (60.5%) had four fractions. Total prescribed Point A dosages (EBRT+HDRICB) ranged from 58 to 71.6 Gy (median, 65.6 Gy) for stage IB-IIA, while for larger lesions (stage IIB-IVA) analogous dosages were 59-75.6 Gy (median, 65.6 Gy). Median follow-up durations for the older and younger groups were 56/55 months, respectively. The respective 5-year actuarial survivals (AS) for the older and younger groups were 82/85% for stage Ib, 65/65% for IIa, 61/71% for IIb and 35/59% for IIIa-b. The 5-year cause-specific survivals (CSS) for the older and

  6. Proficiency-based cervical cancer brachytherapy training.

    Science.gov (United States)

    Zhao, Sherry; Francis, Louise; Todor, Dorin; Fields, Emma C

    2018-04-25

    Although brachytherapy increases the local control rate for cervical cancer, there has been a progressive decline in its use. Furthermore, the training among residency programs for gynecologic brachytherapy varies considerably, with some residents receiving little to no training. This trend is especially concerning given the association between poor applicator placement and decline in local control. Considering the success of proficiency-based training in other procedural specialties, we developed and implemented a proficiency-based cervical brachytherapy training curriculum for our residents. Each resident placed tandem and ovoid applicators with attending guidance and again alone 2 weeks later using a pelvic model that was modified to allow for cervical brachytherapy. Plain films were taken of the pelvic model, and applicator placement quality was evaluated. Other evaluated metrics included retention of key procedural details, the time taken for each procedure and presession and postsession surveys to assess confidence. During the initial session, residents on average met 4.5 of 5 placement criteria, which improved to 5 the second session. On average, residents were able to remember 7.6 of the 8 key procedural steps. Execution time decreased by an average of 10.5%. Resident confidence with the procedure improved dramatically, from 2.6 to 4.6 of 5. Residents who had previously never performed a tandem and ovoid procedure showed greater improvements in these criteria than those who had. All residents strongly agreed that the training was helpful and wanted to participate again the following year. Residents participating in this simulation training had measurable improvements in the time to perform the procedure, applicator placement quality, and confidence. This curriculum is easy to implement and is of great value for training residents, and would be particularly beneficial in programs with low volume of cervical brachytherapy cases. Simulation programs could

  7. Optical fibre luminescence sensor for real-time LDR brachytherapy dosimetry

    Science.gov (United States)

    Woulfe, P.; O'Keeffe, S.; Sullivan, F. J.

    2018-02-01

    An optical fibre sensor for monitoring low dose radiation is presented. The sensor is based on a scintillation material embedded within the optical fibre core, which emits visible light when exposed to low level ionising radiation. The incident level of ionising radiation can be determined by analysing the optical emission. An optical fibre sensor is developed, based on radioluminescence whereby radiation sensitive scintillation material, terbium doped gadolinium oxysulphide (Gd2O2S:Tb), is embedded in a cavity of 700μm of a 1mm plastic optical fibre. The sensor is designed for in-vivo monitoring of the radiation dose during radio-active seed implantation for low dose rate (LDR) brachytherapy, in prostate cancer treatment, providing radiation oncologists with real-time information of the radiation dose to the target area and/or nearby organs at risk (OARs). The radiation from the brachytherapy seeds causes emission of visible light from the scintillation material through the process of radioluminescence, which penetrates the fibre, propagating along the optical fibre for remote detection using a multi-pixel photon counter. The sensor demonstrates a high sensitivity to 0.397mCi of Iodine125, the radioactive source most commonly used in brachytherapy for treating prostate cancer.

  8. 137Cs - Brachytherapy sources : a technology scenario

    International Nuclear Information System (INIS)

    Varma, R.N.

    2001-01-01

    Cancer has emerged as one of the major cause of morbidity and mortality all over the world. India houses world's second largest population and registers 4-5 lakhs new cancer cases every year. Cancer of cervix is most common form of malignancy among Indian women. Radiation therapy, especially intracavity brachytherapy in conjunction with other modalities like surgery, chemotherapy has been found to be highly effective for the management and control of cervical carcinoma at all stages. A technology has been developed indigenously for the fabrication of 137 Cs sources for brachytherapy applications

  9. Poster - 07: Investigations of the Advanced Collapsed-cone Engine for HDR Brachytherapy Scalp Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Cawston-Grant, Brie; Morrison, Hali; Sloboda, Ron; Menon, Geetha [Cross Cancer Institute, University of Alberta, Edmonton (Canada)

    2016-08-15

    Purpose: To present an investigation of the Advanced Collapsed-cone Engine (ACE) in Oncentraê Brachy (OcB) v4.5 using a tissue equivalent phantom modeling scalp brachytherapy (BT) treatments. Methods: A slab phantom modeling the skin, skull, brain and mold was used. A dose of 400cGy was prescribed to just above the skull layer using TG-43 and was delivered using an HDR afterloader. Measurements were made using Gafchromic™ EBT3 film at four depths within the phantom. The TG-43 planned and film measured doses were compared to the standard (sACE) and high (hACE) accuracy ACE options in OcB between the surface and below the skull. Results: The average difference between the TG-43 calculated and film measured doses was −11.25±3.38% when there was no air gap between the mold and skin; sACE and hACE doses were on average lower than TG-43 calculated doses by 3.41±0.03% and 2.45±0.03%, respectively. With a 3mm air gap between the mold and skin, the difference between the TG-43 calculated and measured doses was −8.28±5.76%; sACE and hACE calculations yielded average doses 1.87±0.03% and 1.78±0.04% greater than TG-43, respectively. Conclusions: TG-43, sACE, and hACE were found to overestimate doses below the skull layer compared to film. With a 3mm air gap between the mold and skin, sACE and hACE more accurately predicted the film dose to the skin surface than TG-43. More clinical variations and their implications are currently being investigated.

  10. SU-F-T-11: Scintillator Based Quality Assurance Device for HDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Jozsef, G [New York University Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: To build a test device for HDR afterloaders capable of checking source positions, times at positions and estimate the activity of the source. Methods: A catheter is taped on a plastic scintillation sheet. When a source travels through the catheter, the scintillator sheet lights up around the source. The sheet is monitored with a video camera, and records the movement of the light spot. The center of the spot on each image on the video provides the source location, and the time stamps of the images can provide the dwell time the source spend in each location. Finally, the brightness of the light spot is related to the activity of the source. A code was developed for noise removal, calibrate the scale of the image to centimeters, eliminate the distortion caused by the oblique view angle, identifying the boundaries of the light spot, transforming the image into binary and detect and calculate the source motion, positions and times. The images are much less noisy if the camera is shielded. That requires that the light spot is monitored in a mirror, rather than directly. The whole assembly is covered from external light and has a size of approximately 17×35×25cm (H×L×W) Results: A cheap camera in BW mode proved to be sufficient with a plastic scintillator sheet. The best images were resulted by a 3mm thick sheet with ZnS:Ag surface coating. The shielding of the camera decreased the noise, but could not eliminate it. A test run even in noisy condition resulted in approximately 1 mm and 1 sec difference from the planned positions and dwell times. Activity tests are in progress. Conclusion: The proposed method is feasible. It might simplify the monthly QA process of HDR Brachytherapy units.

  11. Poster - 07: Investigations of the Advanced Collapsed-cone Engine for HDR Brachytherapy Scalp Treatments

    International Nuclear Information System (INIS)

    Cawston-Grant, Brie; Morrison, Hali; Sloboda, Ron; Menon, Geetha

    2016-01-01

    Purpose: To present an investigation of the Advanced Collapsed-cone Engine (ACE) in Oncentraê Brachy (OcB) v4.5 using a tissue equivalent phantom modeling scalp brachytherapy (BT) treatments. Methods: A slab phantom modeling the skin, skull, brain and mold was used. A dose of 400cGy was prescribed to just above the skull layer using TG-43 and was delivered using an HDR afterloader. Measurements were made using Gafchromic™ EBT3 film at four depths within the phantom. The TG-43 planned and film measured doses were compared to the standard (sACE) and high (hACE) accuracy ACE options in OcB between the surface and below the skull. Results: The average difference between the TG-43 calculated and film measured doses was −11.25±3.38% when there was no air gap between the mold and skin; sACE and hACE doses were on average lower than TG-43 calculated doses by 3.41±0.03% and 2.45±0.03%, respectively. With a 3mm air gap between the mold and skin, the difference between the TG-43 calculated and measured doses was −8.28±5.76%; sACE and hACE calculations yielded average doses 1.87±0.03% and 1.78±0.04% greater than TG-43, respectively. Conclusions: TG-43, sACE, and hACE were found to overestimate doses below the skull layer compared to film. With a 3mm air gap between the mold and skin, sACE and hACE more accurately predicted the film dose to the skin surface than TG-43. More clinical variations and their implications are currently being investigated.

  12. American brachytherapy society (ABS) consensus guidelines for brachytherapy of esophageal cancer

    International Nuclear Information System (INIS)

    Gaspar, Laurie E.; Nag, Subir; Herskovic, Arnold; Mantravadi, Rao; Speiser, Burton

    1997-01-01

    Introduction: There is wide variation in the indications, treatment regimens, and dosimetry for brachytherapy in the treatment of cancer of the esophagus. No guidelines for optimal therapy currently exist. Methods and Materials: Utilizing published reports and clinical experience, representatives of the Clinical Research Committee of the American Brachytherapy Society (ABS) formulated guidelines for brachytherapy in esophageal cancer. Results: Recommendations were made for brachytherapy in the definitive and palliative treatment of esophageal cancer. (A) Definitive treatment: Good candidates for brachytherapy include patients with unifocal thoracic adeno- or squamous cancers ≤ 10 cm in length, with no evidence of intra-abdominal or metastatic disease. Contraindications include tracheal or bronchial involvement, cervical esophagus location, or stenosis that cannot be bypassed. The esophageal brachytherapy applicator should have an external diameter of 6-10 mm. If 5FU-based chemotherapy and 45-50-Gy external beam are used, recommended brachytherapy is either: (i) HDR 10 Gy in two weekly fractions of 5 Gy each; or (ii) LDR 20 Gy in a single course at 0.4-1 Gy/hr. All doses are specified 1 cm from the midsource or middwell position. Brachytherapy should follow external beam radiation therapy and should not be given concurrently with chemotherapy. (B) Palliative treatment: Patients with adeno- or squamous cancers of the thoracic esophagus with distant metastases or unresectable local disease progression/recurrence after definitive radiation treatment should be considered for brachytherapy with palliative intent. After limited dose (30 Gy) EBRT, the recommended brachytherapy is either: (i) HDR 10-14 Gy in one or two fractions; or (ii) LDR 20-25 Gy in a single course at 0.4-1 Gy/hr. The need for external beam radiation in newly diagnosed patients with a life expectancy of less than 3 months is controversial. In these cases, HDR of 15-20 Gy in two to four fractions or

  13. Precision of RL/OSL medical dosimetry with fiber-coupled Al2O3:C: Influence of readout delay and temperature variations

    DEFF Research Database (Denmark)

    Andersen, Claus Erik; Morgenthaler Edmund, Jens; Damkjær, Sidsel Marie Skov

    2010-01-01

    Carbon-doped aluminum oxide (Al2O3:C) crystals attached to 15 m optical fiber cables can be used for online in vivo dosimetry during, for example, remotely afterloaded brachytherapy. Radioluminescence (RL) is generated spontaneously in Al2O3:C during irradiation, and this scintillator-like signal...

  14. Remote RemoteRemoteRemote sensing potential for sensing ...

    African Journals Online (AJOL)

    Remote RemoteRemoteRemote sensing potential for sensing potential for sensing potential for sensing potential for sensing potential for sensing potential for sensing potential for sensing potential for sensing potential for sensing potential for sensing p. A Ngie, F Ahmed, K Abutaleb ...

  15. New method for the induction of therapeutic amenorrhea: low dose endometrial afterloading irradiation. Clinical and hormonal studies

    Energy Technology Data Exchange (ETDEWEB)

    Gronroos, M.; Turunen, T.; Raekallio, J.; Ruotsalinen, P.; Salmi, T. (Turku Univ. (Finland). Dept. of Obstetrics and Gynecology)

    1982-08-01

    The authors present a new method for the induction of therapeutic amenorrhea: low dose endometrial afterloading irradiation. The problem with this method has been how to inactivate the endometrium while maintaining the physiological function of the ovaries. In 5/29 young patients regular or irregular bleedings occurred after an endometrial dose of 11+-1 Gy. These subjects were given a repeat low dose intrauterine irradiation. Thereafter no bleedings were found in four out of five patients. Two to 9 years after the repeat irradiation the plasma levels of E/sub 1/, E/sub 2/, FSH and LH corresponded closely to those of healthy women in reproductive age in three out of five patients; some high plasma P levels indicated ovulation. In two patients the E/sub 1/, E/sub 2/, and P values were more likely postmenopausal but, on the other hand, FSH and LH values reproductive ones. 19 refs.

  16. A new method for the induction of therapeutic amenorrhea: low dose endometrial afterloading irradiation. Clinical and hormonal studies

    International Nuclear Information System (INIS)

    Gronroos, M.; Turunen, T.; Raekallio, J.; Ruotsalinen, P.; Salmi, T.

    1982-01-01

    The authors present a new method for the induction of therapeutic amenorrhea: low dose endometrial afterloading irradiation. The problem with this method has been how to inactivate the endometrium while maintaining the physiological function of the ovaries. In 5/29 young patients regular or irregular bleedings occurred after an endometrial dose of 11+-1 Gy. These subjects were given a repeat low dose intrauterine irradiation. Thereafter no bleedings were found in four out of five patients. Two to 9 years after the repeat irradiation the plasma levels of E 1 , E 2 , FSH and LH corresponded closely to those of healthy women in reproductive age in three out of five patients; some high plasma P levels indicated ovulation. In two patients the E 1 , E 2 , and P values were more likely postmenopausal but, on the other hand, FSH and LH values reproductive ones. (author)

  17. Vaginal bacterial flora of patients with operated endometrial carcinoma prior to and following intracavitary vaginal irradiation (Ir-192, afterloading)

    International Nuclear Information System (INIS)

    Gerstner, G.; Kucera, H.; Weghaupt, K.; Rotter, M.; Vienna Univ.; Vienna Univ.

    1982-01-01

    In a prospective bacteriological and clinical study the vaginal bacterial flora of 35 patients with endometrial carcinoma, who underwent surgery 4 to 6 weeks earlier, was investigated prior to and following intracavitary vaginal irradiation with 10 Gy in 0,75 cm (Ir-192, afterloading device, Buchler). Bacteriological swabs were taken prior to and following the insertion of a tube applicator. Anaerobic transport-media were used and cultures were performed aerobically and anaerobically. The mean number of aerobic species per patient increased slightly from 3.26 to 3.60 (n.s.), anaerobic species remained constant (1.36 before and 1.30 after irradiation). Also the frequency of isolation of most aerobic and of all anaerobic species was statistically not altered following irradiation. Staphylococcus epidermidis decreased from 51.4% to 22.8% significantly (2p [de

  18. The use of Selectron afterloading equipment to simulate and extend the Manchester system for intracavitary therapy of the cervix uteri

    International Nuclear Information System (INIS)

    Wilkinson, J.M.; Moore, C.J.; Notley, H.M.; Hunter, R.D.

    1983-01-01

    When Selectron afterloading machines were introduced in the Christie Hospital the first aim was to reproduce, as closely as possible, the isodose distributions achieved with the traditional Manchester Radium System. This resulted in the establishment of standard pellet loading patterns, and standard treatment times, for programming the Selectron channels. However, the availability of whole-body CT scanning facilities provides a method of accurately locating the source positions with respect to the local anatomy and hence the possibility of dosage control based on doses to specific pelvic structures. Various computer programs have been written to extract source position data from the CT images, to allow the operator to propose pellet loading patterns and treatment times, and ultimately to display the resultant isodose distribution superposed on the cross-sectional scans. The effects on the dose distribution arising from changing the number of pellets, the pellet positions within the applicators, and the treatment times, are briefly discussed. (author)

  19. Dose calculation in brachytherapy with microcomputers

    International Nuclear Information System (INIS)

    Elbern, A.W.

    1989-01-01

    The computer algorithms, that allow the calculation of brachytherapy doses and its graphic representation for implants, using programs developed for Pc microcomputers are presented. These algorithms allow to localized the sources in space, from their projection in radiographics images and trace isodose counter. (C.G.C.) [pt

  20. Severe rectal complications after prostate brachytherapy

    International Nuclear Information System (INIS)

    Wallner, Kent; Sutlief, Stephen; Bergsagel, Carl; Merrick, Gregory S.

    2015-01-01

    Purpose: Some investigators have reported severe rectal complications after brachytherapy. Due to the low number of such events, their relationship to dosimetric parameters has not been well characterized. Methods and materials: A total of 3126 patients were treated with low dose rate brachytherapy from 1998 through 2010. 2464 had implant alone, and 313 had implant preceded by 44–46 Gy supplemental external beam radiation (EBRT). Post-implant dosimetry was based on a CT scan obtained on the day of implant, generally within 30 min of the procedure. Every patient’s record was reviewed for occurrence of rectal complications. Results: Eight of 2464 patients (0.32%) treated with brachytherapy alone developed a radiation-related rectal fistula. Average prostatic and rectal dose parameters were moderately higher for fistula patients than for patients without a severe rectal complication. For instance, the average R100 was 1.2 ± 0.75 cc for fistula patients, versus 0.37 ± 0.88 cc for non-fistula patients. However, the fistula patients’ values were well within the range of values for patients without a rectal complication. Four patients had some attempt at repair or reconstruction, but long-term functional outcomes were not favorable. Conclusions: Rectal fistulas are a very uncommon potential complication of prostate brachytherapy, which can occur even in the setting of acceptable day 0 rectal doses. Their occurrence is not easily explained by standard dosimetric or clinical factors

  1. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  2. The hazy dawn of brachytherapy

    International Nuclear Information System (INIS)

    Dutreix, J.; Tubiana, M.; Pierquin, B.

    1998-01-01

    The discovery of radium by Pierre and Marie Curie in December 1898 opened a new era in science and within a few years provided medicine with a new means of tumor treatment. Their personal contribution to the start and early development of clinical applications should not be overlooked. The Curies did not limit their support to providing radium sources to medical pioneers but took a deep interest in the horizons of radiumtherapy. Pierre was one of the first to search for and demonstrate a biological effect of radium radiation. He investigated the radioactivity of the waters of hydrotherapeutic resorts. Marie took care of the measurement of the medical sources personally, convinced that the result of the treatment depends on the precise knowledge of the amount of radium applied. Her perseverance resulted in the establishment of the Institut du Radium (1909) in which, besides the physico-chemical laboratory, a biological department was set up. The latter became the Fondation Curie (1920), a leading medical center of treatment and training, with an integrated team of physicists, radiobiologists and clinicians led by Regaud. One hundred years after the discovery of radium, patients benefit today from the extensive clinical experience that has been collected over the years and from sophisticated developments in application techniques, dosimetry and quality assurance; the professional risk has been precisely assessed and the improvements in material and procedure have enabled the medical personnel to work in hazard-free conditions. This outcome results from the continuous progress that the pioneers gave impulse to. This paper intends to recall their efforts and achievements, as well as the difficulties and the problems they encountered during the first 2 decades when the sturdy foundations of brachytherapy were built. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  3. Dosimetric model for intravascular brachytherapy

    International Nuclear Information System (INIS)

    Flower, E.E.; Stroud, D.B.

    2000-01-01

    Full text: Intravascular brachytherapy has been shown to be a prophylaxis for restenosis. Adventitial macrophages, which are extremely radiosensitive, initiate neointima formation. A model of the dose levels of the treatment range is developed, assuming that the adventitia is the target tissue. If the adventitia receives a dose of less than 10 Gy, it is assumed the treatment will be ineffective. If the dose to any part of the wall is above 30 Gy, it is assumed that the treatment could be detrimental. Hence the treatment range is between 10 and 30 Gy, with 20 Gy being the optimum dosage to the adventitia. An algorithm using numerical integration of published dose kernels calculates the dose at any point surrounding a beta ( 32 P) line source of finite length. Dose profiles were obtained to demonstrate edge effects. For long lesions, the source is often stepped along the artery. Dose changes due to separation or overlapping of sources during source stepping procedures were also determined. Isodose curves were superimposed on intravascular ultrasound images to demonstrate dose levels. For an exposure time of 60 seconds with a 200mCi source, the optimum dose of 20 Gy occurs at a distance 1.94mm from the centre of the source. The upper limit of the treatment dose range (30 Gy) occurs at 1.59mm. The lower limit of the treatment dose range (10 Gy) occurs at 2.7mm. Significant perturbations to the treatment dose range can be caused by non-centering of the source, edge effects and separation or overlapping of sources in stepping procedures. Despite these concerns, many successful procedures have been reported and this implies that the model is over simplified and requires modifications. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  4. Prostate brachytherapy in Ghana: our initial experience

    Directory of Open Access Journals (Sweden)

    James Edward Mensah

    2016-10-01

    Full Text Available Purpose: This study presents the experience of a brachytherapy team in Ghana with a focus on technology transfer and outcome. The team was initially proctored by experienced physicians from Europe and South Africa. Material and methods : A total of 90 consecutive patients underwent either brachytherapy alone or brachytherapy in combination with external beam radiotherapy for prostate carcinoma between July 2008 and February 2014 at Korle Bu Teaching Hospital, Accra, Ghana. Patients were classified as low-risk, intermediate, and high-risk according to the National Comprehensive Cancer Network (NCCN criteria. All low-risk and some intermediate risk group patients were treated with seed implantation alone. Some intermediate and all high-risk group patients received brachytherapy combined with external beam radiotherapy. Results: The median patient age was 64.0 years (range 46-78 years. The median follow-up was 58 months (range 18-74 months. Twelve patients experienced biochemical failure including one patient who had evidence of metastatic disease and died of prostate cancer. Freedom from biochemical failure rates for low, intermediate, and high-risk cases were 95.4%, 90.9%, and 70.8%, respectively. Clinical parameters predictive of biochemical outcome included: clinical stage, Gleason score, and risk group. Pre-treatment prostate specific antigen (PSA was not a statistically significant predictor of biochemical failure. Sixty-nine patients (76.6% experienced grade 1 urinary symptoms in the form of frequency, urgency, and poor stream. These symptoms were mostly self-limiting. Four patients needed catheterization for urinary retention (grade 2. One patient developed a recto urethral fistula (grade 3 following banding for hemorrhoids. Conclusions : Our results compare favorably with those reported by other institutions with more extensive experience. We believe therefore that, interstitial permanent brachytherapy can be safely and effectively

  5. Automated intraoperative calibration for prostate cancer brachytherapy

    International Nuclear Information System (INIS)

    Kuiran Chen, Thomas; Heffter, Tamas; Lasso, Andras; Pinter, Csaba; Abolmaesumi, Purang; Burdette, E. Clif; Fichtinger, Gabor

    2011-01-01

    Purpose: Prostate cancer brachytherapy relies on an accurate spatial registration between the implant needles and the TRUS image, called ''calibration''. The authors propose a new device and a fast, automatic method to calibrate the brachytherapy system in the operating room, with instant error feedback. Methods: A device was CAD-designed and precision-engineered, which mechanically couples a calibration phantom with an exact replica of the standard brachytherapy template. From real-time TRUS images acquired from the calibration device and processed by the calibration system, the coordinate transformation between the brachytherapy template and the TRUS images was computed automatically. The system instantly generated a report of the target reconstruction accuracy based on the current calibration outcome. Results: Four types of validation tests were conducted. First, 50 independent, real-time calibration trials yielded an average of 0.57 ± 0.13 mm line reconstruction error (LRE) relative to ground truth. Second, the averaged LRE was 0.37 ± 0.25 mm relative to ground truth in tests with six different commercial TRUS scanners operating at similar imaging settings. Furthermore, testing with five different commercial stepper systems yielded an average of 0.29 ± 0.16 mm LRE relative to ground truth. Finally, the system achieved an average of 0.56 ± 0.27 mm target registration error (TRE) relative to ground truth in needle insertion tests through the template in a water tank. Conclusions: The proposed automatic, intraoperative calibration system for prostate cancer brachytherapy has achieved high accuracy, precision, and robustness.

  6. Image Guided Cervical Brachytherapy: 2014 Survey of the American Brachytherapy Society

    Energy Technology Data Exchange (ETDEWEB)

    Grover, Surbhi, E-mail: Surbhi.grover@uphs.upenn.edu [Department of Radiation Oncology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Harkenrider, Matthew M. [Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Chicago, Illinois (United States); Cho, Linda P. [Department of Radiation Oncology, Brigham & Women' s Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts (United States); Erickson, Beth [Department Radiation Oncology, Froedtert Hospital and Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Small, Christina [Department of Public Health Sciences, Stritch School of Medicine, Loyola University Chicago, Chicago, Illinois (United States); Small, William [Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Chicago, Illinois (United States); Viswanathan, Akila N. [Department of Radiation Oncology, Brigham & Women' s Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts (United States)

    2016-03-01

    Purpose: To provide an update of the 2007 American brachytherapy survey on image-based brachytherapy, which showed that in the setting of treatment planning for gynecologic brachytherapy, although computed tomography (CT) was often used for treatment planning, most brachytherapists used point A for dose specification. Methods and Materials: A 45-question electronic survey on cervical cancer brachytherapy practice patterns was sent to all American Brachytherapy Society members and additional radiation oncologists and physicists based in the United States between January and September 2014. Responses from the 2007 survey and the present survey were compared using the χ{sup 2} test. Results: There were 370 respondents. Of those, only respondents, not in training, who treat more than 1 cervical cancer patient per year and practice in the United States, were included in the analysis (219). For dose specification to the target (cervix and tumor), 95% always use CT, and 34% always use MRI. However, 46% use point A only for dose specification to the target. There was a lot of variation in parameters used for dose evaluation of target volume and normal tissues. Compared with the 2007 survey, use of MRI has increased from 2% to 34% (P<.0001) for dose specification to the target. Use of volume-based dose delineation to the target has increased from 14% to 52% (P<.0001). Conclusion: Although use of image-based brachytherapy has increased in the United States since the 2007 survey, there is room for further growth, particularly with the use of MRI. This increase may be in part due to educational initiatives. However, there is still significant heterogeneity in brachytherapy practice in the United States, and future efforts should be geared toward standardizing treatment.

  7. Low dose rate Ir-192 interstitial brachytherapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oki, Yosuke; Dokiya, Takushi; Yorozu, Atsunori; Suzuki, Takayuki; Saito, Shiro; Monma, Tetsuo; Ohki, Takahiro [National Tokyo Medical Center (Japan); Murai, Masaru; Kubo, Atsushi

    2000-04-01

    From December 1997 through January 1999, fifteen prostatic cancer patients were treated with low dose rate Ir-192 interstitial brachytherapy using TRUS and perineal template guidance without external radiotherapy. Up to now, as no apparent side effects were found, the safety of this treatment is suggested. In the future, in order to treat prostatic cancer patients with interstitial brachytherapy using I-125 or Pd-103, more investigation for this low dose rate Ir-192 interstitial brachytherapy is needed. (author)

  8. A comparison of complications between ultrasound-guided prostate brachytherapy and open prostate brachytherapy

    International Nuclear Information System (INIS)

    Benoit, Ronald M.; Naslund, Michael J.; Cohen, Jeffrey K.

    2000-01-01

    Purpose: Prostate brachytherapy has reemerged during the 1990s as a treatment for clinically localized prostate cancer. The renewed popularity of prostate brachytherapy is largely due to the use of transrectal ultrasound of the prostate, which allows for more accurate isotope placement within the prostate when compared to the open approach. The present study investigates whether this improved cancer control is at the expense of increased morbidity by comparing the morbidity after transrectal ultrasound-guided prostate brachytherapy to the morbidity after prostate brachytherapy performed via an open approach. Methods and Materials: All men in the Medicare population who underwent prostate brachytherapy in the year 1991 were identified. These men were further stratified into those men who underwent prostate brachytherapy via an open approach and the men who underwent prostate brachytherapy with ultrasound guidance. All subsequent inpatient, outpatient, and physician (Part B) Medicare claims for these men from the years 1991-1993 were then analyzed to determine outcomes. Results: In the year 1991, 2124 men in the Medicare population underwent prostate brachytherapy. An open approach was used in 715 men (33.7%), and ultrasound guidance was used in 1409 men (66.3%). Mean age for both cohorts was 73.7 years with a range of 50.7-92.8 years for the ultrasound group and 60.6-92.1 years for the open group. A surgical procedure for the relief of bladder outlet obstruction was performed in 122 men (8.6%) in the ultrasound group and in 54 men (7.6%) in the open group. An artificial urinary sphincter was placed in 2 men (0.14%) in the ultrasound group and in 2 men (0.28%) in the open group. A penile prosthesis was implanted in 10 men (0.71%) in the ultrasound group and in 4 men (0.56%) in the open group. A diagnosis code for urinary incontinence was carried by 95 men (6.7%) in the ultrasound group and by 45 men (6.3%) in the open group. A diagnosis code for erectile dysfunction

  9. Rectal fistulas after prostate brachytherapy

    International Nuclear Information System (INIS)

    Tran, Audrey; Wallner, Kent; Merrick, Gregory; Seeberger, Jergen M.S.; Armstrong, Julius R.T.T.; Mueller, Amy; Cavanagh, William M.S.; Lin, Daniel; Butler, Wayne

    2005-01-01

    Purpose: To compare the rectal and prostatic radiation doses for a prospective series of 503 patients, 44 of whom developed persistent rectal bleeding, and 2 of whom developed rectal-prostatic fistulas. Methods and Materials: The 503 patients were randomized and treated by implantation with 125 I vs. 103 Pd alone (n = 290) or to 103 Pd with 20 Gy vs. 44 Gy supplemental external beam radiotherapy (n = 213) and treated at the Puget Sound Veterans Affairs Medical Center (n = 227), Schiffler Cancer Center (n 242) or University of Washington (n = 34). Patients were treated between September 1998 and October 2001 and had a minimum of 24 months of follow-up. The patient groups were treated concurrently. Treatment-related morbidity was monitored by mailed questionnaires, using standard American Urological Association and Radiation Therapy Oncology Group criteria, at 1, 3, 6, 12, 18, and 24 months. Patients who reported Grade 1 or greater Radiation Therapy Oncology Group rectal morbidity were interviewed by telephone to clarify details regarding their rectal bleeding. Those who reported persistent bleeding, lasting for >1 month were included as having Grade 2 toxicity. Three of the patients with rectal bleeding required a colostomy, two of whom developed a fistula. No patient was lost to follow-up. The rectal doses were defined as the rectal volume in cubic centimeters that received >50%, 100%, 200%, or 300% of the prescription dose. The rectum was considered as a solid structure defined by the outer wall, without attempting to differentiate the inner wall or contents. Results: Persistent rectal bleeding occurred in 44 of the 502 patients, 32 of whom (73%) underwent confirmatory endoscopy. In univariate analysis, multiple parameters were associated with late rectal bleeding, including all rectal brachytherapy indexes. In multivariate analysis, however, only the rectal volume that received >100% of the dose was significantly predictive of bleeding. Rectal fistulas occurred

  10. Remote Research

    CERN Document Server

    Tulathimutte, Tony

    2011-01-01

    Remote studies allow you to recruit subjects quickly, cheaply, and immediately, and give you the opportunity to observe users as they behave naturally in their own environment. In Remote Research, Nate Bolt and Tony Tulathimutte teach you how to design and conduct remote research studies, top to bottom, with little more than a phone and a laptop.

  11. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy.

    Directory of Open Access Journals (Sweden)

    Luciana Tourinho Campos

    Full Text Available The use of high-dose-rate brachytherapy is currently a widespread practice worldwide. The most common isotope source is 192Ir, but 60Co is also becoming available for HDR. One of main advantages of 60Co compared to 192Ir is the economic and practical benefit because of its longer half-live, which is 5.27 years. Recently, Eckert & Ziegler BEBIG, Germany, introduced a new afterloading brachytherapy machine (MultiSource®; it has the option to use either the 60Co or 192Ir HDR source. The source for the Monte Carlo calculations is the new 60Co source (model Co0.A86, which is referred to as the new BEBIG 60Co HDR source and is a modified version of the 60Co source (model GK60M21, which is also from BEBIG.The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy to investigate the required treatment-planning parameters. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. To validate the source geometry, a few dosimetry parameters had to be calculated according to the AAPM TG-43U1 formalism. The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The spectrum to simulate 60Co was composed of two photon energies, 1.17 and 1.33 MeV. Only the gamma part of the spectrum was used; the contribution of the electrons to the dose is negligible because of the full absorption by the stainless-steel wall around the metallic 60Co. The XCOM photon cross-section library was used in subsequent simulations, and the photoelectric effect, pair

  12. Remote Sensing

    CERN Document Server

    Khorram, Siamak; Koch, Frank H; van der Wiele, Cynthia F

    2012-01-01

    Remote Sensing provides information on how remote sensing relates to the natural resources inventory, management, and monitoring, as well as environmental concerns. It explains the role of this new technology in current global challenges. "Remote Sensing" will discuss remotely sensed data application payloads and platforms, along with the methodologies involving image processing techniques as applied to remotely sensed data. This title provides information on image classification techniques and image registration, data integration, and data fusion techniques. How this technology applies to natural resources and environmental concerns will also be discussed.

  13. Sexual function after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Galbreath, R.W.; Merrick, G.S.; Butler, W.M.; Stipetich, R.L.; Abel, L.J.; Lief, J.H.

    2001-01-01

    Purpose: To determine the incidence of potency preservation following permanent prostate brachytherapy and to evaluate the effect of multiple clinical and treatment parameters on penile erectile function. Materials and Methods: 425 patients underwent permanent prostate brachytherapy from April 1995 to October 1999. 209 patients who were potent prior to brachytherapy and currently not receiving hormonal manipulation were mailed an International Index of Erectile Function (IIEF) questionnaire with a pre-addressed stamped envelope. 180 patients completed and returned the questionnaire. Median patient follow-up was 39 months (range 18-74 months). Pre-implant erectile function was assigned using a three-tiered scoring system (2 = erections always or nearly always sufficient for vaginal penetration; 1 = erections sufficient for vaginal penetration but considered suboptimal; 0 = the inability to obtain erections and/or erections inadequate for vaginal penetration). Post-implant potency was defined as an IIEF score >11. Clinical parameters evaluated for sexual function included patient age, clinical T stage, elapsed time since implantation, hypertension, diabetes mellitus, and tobacco consumption. Evaluated treatment parameters included the utilization of neoadjuvant hormonal manipulation and the choice of isotope. The efficacy of sildenafil citrate in brachytherapy induced erectile dysfunction (ED) was also evaluated. Results: A pre-treatment erectile function score of 2 and 1 were assigned to 126 and 54 patients respectively. With 6 year follow up, 39% of patients maintained potency following prostate brachytherapy with a plateau on the curve. Post-implant preservation of potency (IIEF>11) correlated with pre-implant erectile function (50% versus 14% for pre-implant scores of 2 and 1 respectively, p≤0.0001), patient age (56%, 38%, and 23% for patients <60 years of age, 60-69 years of age, and ≥70 years of age respectively, p=0.012) and a history of diabetes mellitus

  14. The evolution of brachytherapy treatment planning

    International Nuclear Information System (INIS)

    Rivard, Mark J.; Venselaar, Jack L. M.; Beaulieu, Luc

    2009-01-01

    Brachytherapy is a mature treatment modality that has benefited from technological advances. Treatment planning has advanced from simple lookup tables to complex, computer-based dose-calculation algorithms. The current approach is based on the AAPM TG-43 formalism with recent advances in acquiring single-source dose distributions. However, this formalism has clinically relevant limitations for calculating patient dose. Dose-calculation algorithms are being developed based on Monte Carlo methods, collapsed cone, and solving the linear Boltzmann transport equation. In addition to improved dose-calculation tools, planning systems and brachytherapy treatment planning will account for material heterogeneities, scatter conditions, radiobiology, and image guidance. The AAPM, ESTRO, and other professional societies are working to coordinate clinical integration of these advancements. This Vision 20/20 article provides insight into these endeavors.

  15. Radiochromic dye film studies for brachytherapy applications

    International Nuclear Information System (INIS)

    Martinez-Davalos, A.; Rodriguez-Villafuerte, M.; Diaz-Perches, R.; Arzamendi-Perez, S.

    2002-01-01

    Commercial radiochromic dye films have been used in recent years to quantify absorbed dose in several medical applications. In this study we present the characterisation of the GafChromic MD-55-2 dye film, a double sensitive layer film suitable for photon irradiation in brachytherapy applications. Dose measurements were carried out with a low dose rate 137 Cs brachytherapy source, which produces very steep dose gradients in its vicinity, and therefore requires the capability of producing high spatial resolution isodose curves. Quantification of the dose rate in water per unit air kerma strength was obtained using a high-resolution transmission commercial scanner (Agfa DuoScan T1200) with the capability of digitising up to 600 x 1200 pixels per inch using 36 bits per pixel, together with optical density measurements. The Monte Carlo calculations and experimental measurements compared well in the 0-50 Gy dose interval used in this study. (author)

  16. ENT COBRA (Consortium for Brachytherapy Data Analysis: interdisciplinary standardized data collection system for head and neck patients treated with interventional radiotherapy (brachytherapy

    Directory of Open Access Journals (Sweden)

    Luca Tagliaferri

    2016-08-01

    Full Text Available Purpose : Aim of the COBRA (Consortium for Brachytherapy Data Analysis project is to create a multicenter group (consortium and a web-based system for standardized data collection. Material and methods: GEC-ESTRO (Groupe Européen de Curiethérapie – European Society for Radiotherapy & Oncology Head and Neck (H&N Working Group participated in the project and in the implementation of the consortium agreement, the ontology (data-set and the necessary COBRA software services as well as the peer reviewing of the general anatomic site-specific COBRA protocol. The ontology was defined by a multicenter task-group. Results : Eleven centers from 6 countries signed an agreement and the consortium approved the ontology. We identified 3 tiers for the data set: Registry (epidemiology analysis, Procedures (prediction models and DSS, and Research (radiomics. The COBRA-Storage System (C-SS is not time-consuming as, thanks to the use of “brokers”, data can be extracted directly from the single center’s storage systems through a connection with “structured query language database” (SQL-DB, Microsoft Access®, FileMaker Pro®, or Microsoft Excel®. The system is also structured to perform automatic archiving directly from the treatment planning system or afterloading machine. The architecture is based on the concept of “on-purpose data projection”. The C-SS architecture is privacy protecting because it will never make visible data that could identify an individual patient. This C-SS can also benefit from the so called “distributed learning” approaches, in which data never leave the collecting institution, while learning algorithms and proposed predictive models are commonly shared. Conclusions : Setting up a consortium is a feasible and practicable tool in the creation of an international and multi-system data sharing system. COBRA C-SS seems to be well accepted by all involved parties, primarily because it does not influence the center’s own

  17. Brachytherapy needle deflection evaluation and correction

    International Nuclear Information System (INIS)

    Wan Gang; Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-01-01

    In prostate brachytherapy, an 18-gauge needle is used to implant radioactive seeds. This thin needle can be deflected from the preplanned trajectory in the prostate, potentially resulting in a suboptimum dose pattern and at times requiring repeated needle insertion to achieve optimal dosimetry. In this paper, we report on the evaluation of brachytherapy needle deflection and bending in test phantoms and two approaches to overcome the problem. First we tested the relationship between needle deflection and insertion depth as well as whether needle bending occurred. Targeting accuracy was tested by inserting a brachytherapy needle to target 16 points in chicken tissue phantoms. By implanting dummy seeds into chicken tissue phantoms under 3D ultrasound guidance, the overall accuracy of seed implantation was determined. We evaluated methods to overcome brachytherapy needle deflection with three different insertion methods: constant orientation, constant rotation, and orientation reversal at half of the insertion depth. Our results showed that needle deflection is linear with needle insertion depth, and that no noticeable bending occurs with needle insertion into the tissue and agar phantoms. A 3D principal component analysis was performed to obtain the population distribution of needle tip and seed position relative to the target positions. Our results showed that with the constant orientation insertion method, the mean needle targeting error was 2.8 mm and the mean seed implantation error was 2.9 mm. Using the constant rotation and orientation reversal at half insertion depth methods, the deflection error was reduced. The mean needle targeting errors were 0.8 and 1.2 mm for the constant rotation and orientation reversal methods, respectively, and the seed implantation errors were 0.9 and 1.5 mm for constant rotation insertion and orientation reversal methods, respectively

  18. Erectile Function Durability Following Permanent Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Taira, Al V.; Merrick, Gregory S.; Galbreath, Robert W.; Butler, Wayne M.; Wallner, Kent E.; Kurko, Brian S.; Anderson, Richard; Lief, Jonathan H.

    2009-01-01

    Purpose: To evaluate long-term changes in erectile function following prostate brachytherapy. Methods and Materials: This study included 226 patients with prostate cancer and preimplant erectile function assessed by the International Index of Erectile Function-6 (IIEF-6) who underwent brachytherapy in two prospective randomized trials between February 2001 and January 2003. Median follow-up was 6.4 years. Pre- and postbrachytherapy potency was defined as IIEF-6 ≥ 13 without pharmacologic or mechanical support. The relationship among clinical, treatment, and dosimetric parameters and erectile function was examined. Results: The 7-year actuarial rate of potency preservation was 55.6% with median postimplant IIEF of 22 in potent patients. Potent patients were statistically younger (p = 0.014), had a higher preimplant IIEF (p < 0.001), were less likely to be diabetic (p = 0.002), and were more likely to report nocturnal erections (p = 0.008). Potency preservation in men with baseline IIEF scores of 29-30, 24-28, 18-23, and 13-17 were 75.5% vs. 73.6%, 51.7% vs. 44.8%, 48.0% vs. 40.0%, and 23.5% vs. 23.5% in 2004 vs. 2008. In multivariate Cox regression analysis, preimplant IIEF, hypertension, diabetes, prostate size, and brachytherapy dose to proximal penis strongly predicted for potency preservation. Impact of proximal penile dose was most pronounced for men with IIEF of 18-23 and aged 60-69. A significant minority of men who developed postimplant impotence ultimately regained erectile function. Conclusion: Potency preservation and median IIEF scores following brachytherapy are durable. Thoughtful dose sparing of proximal penile structures and early penile rehabilitation may further improve these results.

  19. Design and optimization of a brachytherapy robot

    Science.gov (United States)

    Meltsner, Michael A.

    Trans-rectal ultrasound guided (TRUS) low dose rate (LDR) interstitial brachytherapy has become a popular procedure for the treatment of prostate cancer, the most common type of non-skin cancer among men. The current TRUS technique of LDR implantation may result in less than ideal coverage of the tumor with increased risk of negative response such as rectal toxicity and urinary retention. This technique is limited by the skill of the physician performing the implant, the accuracy of needle localization, and the inherent weaknesses of the procedure itself. The treatment may require 100 or more sources and 25 needles, compounding the inaccuracy of the needle localization procedure. A robot designed for prostate brachytherapy may increase the accuracy of needle placement while minimizing the effect of physician technique in the TRUS procedure. Furthermore, a robot may improve associated toxicities by utilizing angled insertions and freeing implantations from constraints applied by the 0.5 cm-spaced template used in the TRUS method. Within our group, Lin et al. have designed a new type of LDR source. The "directional" source is a seed designed to be partially shielded. Thus, a directional, or anisotropic, source does not emit radiation in all directions. The source can be oriented to irradiate cancerous tissues while sparing normal ones. This type of source necessitates a new, highly accurate method for localization in 6 degrees of freedom. A robot is the best way to accomplish this task accurately. The following presentation of work describes the invention and optimization of a new prostate brachytherapy robot that fulfills these goals. Furthermore, some research has been dedicated to the use of the robot to perform needle insertion tasks (brachytherapy, biopsy, RF ablation, etc.) in nearly any other soft tissue in the body. This can be accomplished with the robot combined with automatic, magnetic tracking.

  20. Dosimetry in high dose rate endoluminal brachytherapy

    International Nuclear Information System (INIS)

    Uno, Takashi; Kotaka, Kikuo; Itami, Jun

    1994-01-01

    In endoluminal brachytherapy for the tracheobronchial tree, esophagus, and bile duct, a reference point for dose calculation has been often settled at 1 cm outside from the middle of source travel path. In the current study, a change in the ratio of the reference point dose on the convex to concave side (Dq/Dp) was calculated, provided the source travel path bends as is the case in most endoluminal brachytherapies. Point source was presumed to move stepwise at 1 cm interval from 4 to 13 locations. Retention time at each location was calculated by personal computer so as to deliver equal dose at 1 cm from the linear travel path. With the retention time remaining constant, the change of Dq/Dp was assessed by bending the source travel path. Results indicated that the length of the source travel path and radius of its curve influenced the pattern of change in Dq/Dp. Therefore, it was concluded that the difference in reference dose on the convex and concave side of the curved path is not negligible under certain conditions in endoluminal brachytherapy. In order to maintain the ratio more than 0.9, relatively greater radius was required when the source travel path was decreased. (author)

  1. Radioactive seed immobilization techniques for interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yan, K.; Podder, T.; Buzurovic, I.; Hu, Y.; Dicker, A.; Valicenti, R.; Yu, Y.; Messing, E.; Rubens, D.; Sarkar, N.; Ng, W.

    2008-01-01

    In prostate brachytherapy, seeds can detach from their deposited sites and move locally in the pelvis or migrate to distant sites including the pulmonary and cardiac regions. Undesirable consequences of seed migration include inadequate dose coverage of the prostate and tissue irradiation effects at the site of migration. Thus, it is clinically important to develop seed immobilization techniques. We first analyze the possible causes for seed movement, and propose three potential techniques for seed immobilization: (1) surgical glue, (2) laser coagulation and (3) diathermy coagulation. The feasibility of each method is explored. Experiments were carried out using fresh bovine livers to investigate the efficacy of seed immobilization using surgical glue. Results have shown that the surgical glue can effectively immobilize the seeds. Evaluation of the radiation dose distribution revealed that the non-immobilized seed movement would change the planned isodose distribution considerably; while by using surgical glue method to immobilize the seeds, the changes were negligible. Prostate brachytherapy seed immobilization is necessary and three alternative mechanisms are promising for addressing this issue. Experiments for exploring the efficacy of the other two proposed methods are ongoing. Devices compatible with the brachytherapy procedure will be designed in future. (orig.)

  2. A fibre optic dosimeter customised for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Suchowerska, N. [Department of Radiation Oncology, Royal Prince Alfred Hospital, Camperdown, NSW 2050 (Australia); School of Physics, University of Sydney, NSW 2006 (Australia)], E-mail: Natalka@email.cs.nsw.gov.au; Lambert, J.; Nakano, T. [Department of Radiation Oncology, Royal Prince Alfred Hospital, Camperdown, NSW 2050 (Australia); School of Physics, University of Sydney, NSW 2006 (Australia); Law, S. [School of Physics, University of Sydney, NSW 2006 (Australia); Optical Fibre Technology Centre, University of Sydney, 206 National Innovation Centre, Australian Technology Park, Eveleigh, NSW 1430 (Australia); Elsey, J. [Bandwidth Foundry Pty Ltd, Australian Technology Park, NSW, 1430 (Australia); McKenzie, D.R. [School of Physics, University of Sydney, NSW 2006 (Australia)

    2007-04-15

    In-vivo dosimetry for brachytherapy cancer treatment requires a small dosimeter with a real time readout capability that can be inserted into the patient to determine the dose to critical organs. Fibre optic scintillation dosimeters, consisting of a plastic scintillator coupled to an optical fibre, are a promising dosimeter for this application. We have implemented specific design features to optimise the performance of the dosimeter for specific in-vivo dosimetry during brachytherapy. Two sizes of the BrachyFOD{sup TM} scintillation dosimeter have been developed, with external diameters of approximately 2 and 1 mm. We have determined their important dosimetric characteristics (depth dose relation, angular dependence, energy dependence). We have shown that the background signal created by Cerenkov and fibre fluorescence does not significantly affect the performance in most clinical geometries. The dosimeter design enables readout at less than 0.5 s intervals. The clinical demands of real time in-vivo brachytherapy dosimetry can uniquely be satisfied by the BrachyFOD{sup TM}.

  3. Permanent Prostate Brachytherapy in Prostate Glands 3

    International Nuclear Information System (INIS)

    Mayadev, Jyoti; Merrick, Gregory S.; Reed, Joshua R.; Butler, Wayne M.; Galbreath, Robert W.; Allen, Zachariah A.; Wallner, Kent E.

    2010-01-01

    Purpose: To investigate the dosimetry, treatment-related morbidity, and biochemical outcomes for brachytherapy in patients with prostate glands 3 . Methods and Materials: From November 1996 to October 2006, 104 patients with prostate glands 3 underwent brachytherapy. Multiple prostate, urethral, and rectal dosimetric parameters were evaluated. Treatment-related urinary and rectal morbidity were assessed from patient questionnaires. Cause-specific survival, biochemical progression-free survival, and overall survival were recorded. Results: The median patient age, follow up, and pre-treatment ultrasound volume was 64 years, 5.0 years and 17.6cm 3 , respectively. Median day 0 dosimetry was significant for the following: V100 98.5%, D90 126.1% and R100 <0.5% of prescription dose. The mean urethral and maximum urethral doses were 119.6% and 133.8% of prescription. The median time to International Prostate Symptom Score resolution was 4 months. There were no RTOG grade III or IV rectal complications. The cause-specific survival, biochemical progression-free survival, and overall survival rates were 100%, 92.5%, and 77.8% at 9 years. For biochemically disease-free patients, the median most recent postbrachytherapy PSA value was 0.02 ng/mL. Conclusion: Our results demonstrate that brachytherapy for small prostate glands is highly effective, with an acceptable morbidity profile, excellent postimplant dosimetry, acceptable treatment-related morbidity, and favorable biochemical outcomes.

  4. Brachytherapy treatment with high dose rate

    International Nuclear Information System (INIS)

    Santana Rodriguez, Sergio Marcelino; Rodriguez Rodriguez, Lissi Lisbet; Ciscal Chiclana, Onelio Alberto

    2009-01-01

    Retrospectively analyze results and prognostic factors of cervical cancer patients treated with radio concomitant cisplatin-based chemotherapy, radiation therapy combined modality. Methods: From January 2003 to December 2007, 198 patients with invasive cervical cancer were treated at the Oncology Department of Hospital Robau Celestino Hernandez (brachytherapy performed at INOR). The most common age group was 31 to 40 years. The histology in squamous cell carcinoma accounted for 84.3% of cases. The treatment consisted of external pelvic irradiation and vaginal brachytherapy, high dose rate. Concomitant chemotherapy consisted of cisplatin 40 mg/m2 weekly with a maximum of 70 mg for 5 weeks. Results: 66.2% of patients completed 5 cycles of chemotherapy. The median overall survival was 39 months, overall survival, disease-free survival and survival free of locoregional recurrence at 5 years of 78%, 76% and 78.6% respectively .. We found that clinical stage, histological type (adenocarcinoma worst outcome) were statistically related to level of response. Conclusions: Treatment with external pelvic radiation, brachytherapy and concurrent weekly cisplatin in patients with stage IIIB cervical cancer is feasible in the Chilean public health system, well tolerated and results comparable to international literature. (Author)

  5. Image based brachytherapy planning with special reference to gynaecological cancers

    International Nuclear Information System (INIS)

    Kirisits, C.

    2008-01-01

    Cervical cancer is the most common cancer among women in India and one of the most frequent malignancies in Europe and in North America. In addition endometrium, vagina and vulva cancer are treated with brachytherapy. Especially for locally advanced cervix cancer the integration of image based brachytherapy planning into clinical routine is becoming a new standard for the future

  6. A robotic device for MRI-guided prostate brachytherapy

    NARCIS (Netherlands)

    Lagerburg, V.

    2008-01-01

    One of the treatment options for prostate cancer is brachytherapy with iodine-125 sources. In prostate brachytherapy a high radiation dose is delivered to the prostate with a steep dose fall off to critical surrounding organs. The implantation of the iodine sources is currently performed under

  7. Brachytherapy in the treatment of cervical cancer: a review

    Directory of Open Access Journals (Sweden)

    Banerjee R

    2014-05-01

    Full Text Available Robyn Banerjee,1 Mitchell Kamrava21Department of Radiation Oncology, Tom Baker Cancer Centre, Calgary, Alberta, Canada; 2Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA, USAAbstract: Dramatic advances have been made in brachytherapy for cervical cancer. Radiation treatment planning has evolved from two-dimensional to three-dimensional, incorporating magnetic resonance imaging and/or computed tomography into the treatment paradigm. This allows for better delineation and coverage of the tumor, as well as improved avoidance of surrounding organs. Consequently, advanced brachytherapy can achieve very high rates of local control with a reduction in morbidity, compared with historic approaches. This review provides an overview of state-of-the-art gynecologic brachytherapy, with a focus on recent advances and their implications for women with cervical cancer.Keywords: cervical cancer, brachytherapy, image-guided brachytherapy

  8. Accelerated partial breast irradiation utilizing balloon brachytherapy techniques

    International Nuclear Information System (INIS)

    Strauss, Jonathan B.; Dickler, Adam

    2009-01-01

    To overcome the barriers to BCT, methods of PBI in the setting of breast conservation have been explored. The method of PBI with the longest published follow-up is multi-catheter interstitial brachytherapy. Balloon-based brachytherapy with the MammoSite brachytherapy applicator was designed to simplify the brachytherapy procedure for PBI, enhance the reproducibility of the dosimetry, and improve patient comfort. The rates of local recurrence following PBI with the MammoSite applicator have been low, but there are few published reports and follow-up has been relatively short. The cosmetic outcomes and toxicity of MammoSite PBI are comparable to those seen after multicatheter-based PBI. Additional methods of balloon brachytherapy, including Xoft and SenoRx Contura have been developed. Finally, long-term follow-up after PBI is important for the welfare of individual patients and in order to establish the efficacy, late toxicity and cosmetic outcomes of this technique.

  9. Brachytherapy in the treatment of head and neck cancer

    International Nuclear Information System (INIS)

    Yoo, Seong Yul

    1999-01-01

    Brachytherapy has been proved to be an effective method for the purpose of increasing radiation dose to the tumor and reducing the dose to the surrounding normal tissue. In head and neck cancer, the rationale of brachytherapy is as follows; Firstly, early small lesion is radiocurative and the major cause of failure is local recurrence. Secondly, it can diminish evidently the dose to the normal tissue especially masseteric muscle and salivary gland. Thirdly, the anatomy of head and neck is suitable to various technique of brachytherapy. On background of accumulated experience of LDR iridium brachytherapy of head and neck cancer for the last 15 years, the author reviewed the history of radioisotope therapy, the characteristics of radionuclides, and some important things in the method, clinical technique and treatment planning. The author analyzed the clinical result of 185 cases of head and neck cancer treated in the Korea Cancer Center Hospital. Finally the future prospect of brachytherapy of head and neck cancer is discussed

  10. Dosimetry of iridium-192 sources used in brachytherapy

    International Nuclear Information System (INIS)

    Henn, Keli Cristina

    1999-09-01

    The use of high dose rate brachytherapy (HDR) has been increasing in recent years, due to several advantages relative to conventional low dose rate brachytherapy, such as: shorter treatment times, the ability to fractionate treatment (and thus perform many treatments on an outpatient basis) and reduced worker exposures. Most HDR equipment uses small, high activity 192 Ir sources, which are introduced into the patient using a remote system. The dose distribution around these sources is strongly dependent on the size and shape of the active volume and on the encapsulation of the source. The objective of this work is to compare two methods of calibrating sources of 192 Ir, mamely, measurements in air with an ionization thimble chamber or with a well-type ionization chamber. In addition, we measured the anisotropy of the sources and made comparisons with values supplied by the manufacturer, since this factor is taken into account in the planning system algorithm when dose distributions are calculated. The dose was also evaluated at points of clinical interest (i.e. in the rectum and bladder) and compared to values obtained with the Nucletron PLATO-BPS planning system. The use of lead for rectal protection was evaluated in a cylindrical applicator, aiming the further development of a gynecological applicator. The results of the calibration of seven sources showed that the uncertainty in the calibration in a 'jig' system is smaller than 1%, compared to the value supplied by the source manufacturer. The differences between the results obtained with the well-type ionization camera and the 'jig' system were around 2%. The anisotropy showed good agreement with the values supplied by the manufacturer. The results show that the anisotropy factors, in air and water, are approximately constant and equal to 1.0, for angles between 70 deg and 150 deg. For angles smaller than 70 deg the anisotropy factor in water is larger than in air. Results are also presented for 180 deg, which

  11. Directional interstitial brachytherapy from simulation to application

    Science.gov (United States)

    Lin, Liyong

    Organs at risk (OAR) are sometimes adjacent to or embedded in or overlap with the clinical target volume (CTV) to be treated. The purpose of this PhD study is to develop directionally low energy gamma-emitting interstitial brachytherapy sources. These sources can be applied between OAR to selectively reduce hot spots in the OARs and normal tissues. The reduction of dose over undesired regions can expand patient eligibility or reduce toxicities for the treatment by conventional interstitial brachytherapy. This study covers the development of a directional source from design optimization to construction of the first prototype source. The Monte Carlo code MCNP was used to simulate the radiation transport for the designs of directional sources. We have made a special construction kit to assemble radioactive and gold-shield components precisely into D-shaped titanium containers of the first directional source. Directional sources have a similar dose distribution as conventional sources on the treated side but greatly reduced dose on the shielded side, with a sharp dose gradient between them. A three-dimensional dose deposition kernel for the 125I directional source has been calculated. Treatment plans can use both directional and conventional 125I sources at the same source strength for low-dose-rate (LDR) implants to optimize the dose distributions. For prostate tumors, directional 125I LDR brachytherapy can potentially reduce genitourinary and gastrointestinal toxicities and improve potency preservation for low risk patients. The combination of better dose distribution of directional implants and better therapeutic ratio between tumor response and late reactions enables a novel temporary LDR treatment, as opposed to permanent or high-dose-rate (HDR) brachytherapy for the intermediate risk T2b and high risk T2c tumors. Supplemental external-beam treatments can be shortened with a better brachytherapy boost for T3 tumors. In conclusion, we have successfully finished the

  12. Penile brachytherapy: Results for 49 patients

    International Nuclear Information System (INIS)

    Crook, Juanita M.; Jezioranski, John; Grimard, Laval; Esche, Bernd; Pond, G.

    2005-01-01

    Purpose: To report results for 49 men with squamous cell carcinoma (SCC) of the penis treated with primary penile interstitial brachytherapy at one of two institutions: the Ottawa Regional Cancer Center, Ottawa, and the Princess Margaret Hospital, Toronto, Ontario, Canada. Methods and Materials: From September 1989 to September 2003, 49 men (mean age, 58 years; range, 22-93 years) had brachytherapy for penile SCC. Fifty-one percent of tumors were T1, 33% T2, and 8% T3; 4% were in situ and 4% Tx. Grade was well differentiated in 31%, moderate in 45%, and poor in 2%; grade was unspecified for 20%. One tumor was verrucous. All tumors in Toronto had pulsed dose rate (PDR) brachytherapy (n = 23), whereas those in Ottawa had either Iridium wire (n 22) or seeds (n = 4). Four patients had a single plane implant with a plastic tube technique, and all others had a volume implant with predrilled acrylic templates and two or three parallel planes of needles (median, six needles). Mean needle spacing was 13.5 mm (range, 10-18 mm), mean dose rate was 65 cGy/h (range, 33-160 cGy/h), and mean duration was 98.8 h (range, 36-188 h). Dose rates for PDR brachytherapy were 50-61.2 cGy/h, with no correction in total dose, which was 60 Gy in all cases. Results: Median follow-up was 33.4 months (range, 4-140 months). At 5 years, actuarial overall survival was 78.3% and cause-specific survival 90.0%. Four men died of penile cancer, and 6 died of other causes with no evidence of recurrence. The cumulative incidence rate for never having experienced any type of failure at 5 years was 64.4% and for local failure was 85.3%. All 5 patients with local failure were successfully salvaged by surgery; 2 other men required penectomy for necrosis. The soft tissue necrosis rate was 16% and the urethral stenosis rate 12%. Of 8 men with regional failure, 5 were salvaged by lymph node dissection with or without external radiation. All 4 men with distant failure died of disease. Of 49 men, 42 had an intact

  13. Erectile function after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Galbreath, Robert W.; Stipetich, Robin L.; Abel, Laurie J.; Lief, Jonathan H.

    2002-01-01

    Purpose: To determine the incidence of potency preservation after permanent prostate brachytherapy using a validated patient-administered questionnaire and to evaluate the effect of multiple clinical and treatment parameters on penile erectile function. Methods and Materials: Four hundred twenty-five patients underwent permanent prostate brachytherapy from April 1995 to October 1999. Two hundred nine patients who were potent before brachytherapy and who at the time of the survey were not receiving hormonal therapy were mailed the specific erectile questions of the International Index of Erectile Function (IIEF) questionnaire with a self-addressed stamped envelope. The questionnaire consisted of 5 questions, with a maximal score of 25. Of the 209 patients, 181 (87%) completed and returned the questionnaire. The mean and median follow-up was 40.4±14.9 and 40.6 months, respectively (range 19-75). Preimplant erectile function was assigned using a three-tiered scoring system (2 = erections always or nearly always sufficient for vaginal penetration; 1 = erections sufficient for vaginal penetration but considered suboptimal; 0 = the inability to obtain erections and/or erections inadequate for vaginal penetration). Postimplant potency was defined as an IIEF score ≥11. The clinical parameters evaluated for erectile function included patient age, preimplant potency, clinical T-stage, pretreatment prostate-specific antigen level, Gleason score, elapsed time after implantation, hypertension, diabetes mellitus, and tobacco consumption. Treatment parameters included radiation dose to the prostate gland, use of hormonal manipulation, use of supplemental external beam radiotherapy (EBRT), choice of isotope, prostate volume, and planning volume. The efficacy of sildenafil citrate in brachytherapy-induced erectile dysfunction (ED) was also evaluated. Results: Pretreatment erectile function scores of 2 and 1 were assigned to 125 and 56 patients, respectively. With a 6-year follow

  14. The american brachytherapy society recommendations for permanent prostate brachytherapy postimplant dosimetric analysis

    International Nuclear Information System (INIS)

    Nag, Subir; Bice, William; Wyngaert, Keith de; Prestidge, Bradley; Stock, Richard; Yu Yan

    2000-01-01

    Purpose: The purpose of this report is to establish guidelines for postimplant dosimetric analysis of permanent prostate brachytherapy. Methods: Members of the American Brachytherapy Society (ABS) with expertise in prostate dosimetry evaluation performed a literature review and supplemented with their clinical experience formulated guidelines for performing and analyzing postimplant dosimetry of permanent prostate brachytherapy. Results: The ABS recommends that postimplant dosimetry should be performed on all patients undergoing permanent prostate brachytherapy for optimal patient care. At present, computed tomography (CT)-based dosimetry is recommended, based on availability cost and the ability to image the prostate as well as the seeds. Additional plane radiographs should be obtained to verify the seed count. Until the ideal postoperative interval for CT scanning has been determined, each center should perform dosimetric evaluation of prostate implants at a consistent postoperative interval. This interval should be reported. Isodose displays should be obtained at 50%, 80%, 90%, 100%, 150%, and 200% of the prescription dose and displayed on multiple cross-sectional images of the prostate. A dose-volume histogram (DVH) of the prostate should be performed and the D 90 (dose to 90% of the prostate gland) reported by all centers. Additionally, the D 80, D 100, the fractional V 80, V 90, V 100, V 150, and V 200, (i.e., the percentage of prostate volume receiving 80%, 90%, 100%, 150%, and 200% of the prescribed dose, respectively), the rectal, and urethral doses should be reported and ultimately correlated with clinical outcome in the research environment. On-line real-time dosimetry, the effects of dose heterogeneity, and the effects of tissue heterogeneity need further investigation. Conclusion: It is essential that postimplant dosimetry should be performed on all patients undergoing permanent prostate brachytherapy. Guidelines were established for the performance

  15. Biology of dose rate in brachytherapy

    International Nuclear Information System (INIS)

    Brenner, David J.

    1995-01-01

    Purpose: This course is designed for practitioners and beginners in brachytherapy. The aim is to review biological principles underlying brachytherapy, to understand why current treatment regimes are the way they are, and to discuss what the future may hold in store. Brachytherapy has a long history. It was suggested as long ago as 1903 by Alexander Graham Bell, and the optimal application of this technique has been a subject of debate ever since. 'Brachy' means 'short', and the essential features of conventional brachytherapy are: positioning of the source a short distance from, or in, the tumor, allowing good dose distributions; short overall treatment times, to counter tumor repopulation; low dose rate, enabling a good therapeutic advantage between tumor control and damage to late-responding tissue. The advantages of good dose distributions speak for themselves; in some situations, as we shall see, computer-based dose optimization can be used to improve them still further. The advantages of short overall times stem from the fact that accelerated repopulation of the tumor typically begins a few weeks after the start of a radiation treatment. If all the radiation can be crammed in before that time, the risks of tumor repopulation can be considerably reduced. In fact even external-beam radiotherapy is moving in this direction, with the use of highly accelerated protocols. The advantages of low dose rate stem from the differential response to fractionation of early- and late-responding tissues. Essentially, lowering the dose rate spares late-responding tissue more than it does early-responding tissue such as tumors. We shall also discuss some recent innovations in the context of the general principles that have been outlined. For example, High dose rate brachytherapy, particularly for the uterine cervix: Does it work? If so, when and why? Use of Ir-192 sources, with a half life of 70 days: Should corrections be made for changing biological effectiveness as the dose

  16. Multihelix rotating shield brachytherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Dadkhah, Hossein [Department of Biomedical Engineering, University of Iowa, 1402 Seamans Center for the Engineering Arts and Sciences, Iowa City, Iowa 52242 (United States); Kim, Yusung; Flynn, Ryan T., E-mail: ryan-flynn@uiowa.edu [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States); Wu, Xiaodong [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 and Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center for the Engineering Arts and Sciences, Iowa City, Iowa 52242 (United States)

    2015-11-15

    Purpose: To present a novel brachytherapy technique, called multihelix rotating shield brachytherapy (H-RSBT), for the precise angular and linear positioning of a partial shield in a curved applicator. H-RSBT mechanically enables the dose delivery using only linear translational motion of the radiation source/shield combination. The previously proposed approach of serial rotating shield brachytherapy (S-RSBT), in which the partial shield is rotated to several angular positions at each source dwell position [W. Yang et al., “Rotating-shield brachytherapy for cervical cancer,” Phys. Med. Biol. 58, 3931–3941 (2013)], is mechanically challenging to implement in a curved applicator, and H-RSBT is proposed as a feasible solution. Methods: A Henschke-type applicator, designed for an electronic brachytherapy source (Xoft Axxent™) and a 0.5 mm thick tungsten partial shield with 180° or 45° azimuthal emission angles and 116° asymmetric zenith angle, is proposed. The interior wall of the applicator contains six evenly spaced helical keyways that rigidly define the emission direction of the partial radiation shield as a function of depth in the applicator. The shield contains three uniformly distributed protruding keys on its exterior wall and is attached to the source such that it rotates freely, thus longitudinal translational motion of the source is transferred to rotational motion of the shield. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients with a diverse range of high-risk target volume (HR-CTV) shapes and applicator positions. For each patient, the total number of emission angles was held nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. Treatment delivery time and tumor coverage (D{sub 90} of HR-CTV) were the two metrics used as the basis for evaluation and

  17. Caudal epidural anesthesia during intracavitary brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Isoyama-Shirakawa, Yuko; Abe, Madoka; Nakamura, Katsumasa

    2015-01-01

    It has been suggested that pain control during intracavitary brachytherapy for cervical cancer is insufficient in most hospitals in Japan. Our hospital began using caudal epidural anesthesia during high-dose-rate (HDR) intracavitary brachytherapy in 2011. The purpose of the present study was to retrospectively investigate the effects of caudal epidural anesthesia during HDR intracavitary brachytherapy for cervical cancer patients. Caudal epidural anesthesia for 34 cervical cancer patients was performed during HDR intracavitary brachytherapy between October 2011 and August 2013. We used the patients' self-reported Numeric Rating Scale (NRS) score at the first session of HDR intracavitary brachytherapy as a subjective evaluation of pain. We compared NRS scores of the patients with anesthesia with those of 30 patients who underwent HDR intracavitary brachytherapy without sacral epidural anesthesia at our hospital between May 2010 and August 2011. Caudal epidural anesthesia succeeded in 33 patients (97%), and the NRS score was recorded in 30 patients. The mean NRS score of the anesthesia group was 5.17 ± 2.97, significantly lower than that of the control group's 6.80 ± 2.59 (P = 0.035). The caudal epidural block resulted in no side-effects. Caudal epidural anesthesia is an effective and safe anesthesia option during HDR intracavitary brachytherapy for cervical cancer. (author)

  18. Iridium-192 sources production for brachytherapy use

    International Nuclear Information System (INIS)

    Rostelato, Maria Elisa Chuery Martins

    1997-01-01

    The incidence of cancer increases every year in Brazil and turns out to be one of the most important causes of mortality. Some of the patients are treated with brachytherapy, a form of lesion treatment which is based on the insertion of sources into tumors, in this particular case, activated iridium wires. During this process, the ionizing radiation efficiently destroys the malignant cells. These iridium wires have a nucleus made out of an iridium-platinum alloy 20-30/70-80 of 0,1 mm in diameter either coated by platinum or encased in a platinum tube. The technique consists in irradiating the wire in the reactor neutron flux in order to produce iridium-192. The linear activity goes from 1 mCi/cm to 4 mCi/cm and the basic characteristic, which is required, is the homogeneity of the activation along the wire. It should not present a dispersion exceeding 5% on a wire measuring 50 cm in length, 0.5 mm or 0.3 mm in diameter. Several experiments were carried out in order to define the activation parameters. Wires from different origins were analyzed. It was concluded that United States of America and France wires were found to be perfectly adequate for brachytherapy purposes and have therefore been sent to specialized hospitals and successfully applied to cancer patients. Considering that the major purpose of this work is to make this product more accessible in Brazil, at a cost reflecting the Brazilian reality, the IPEN is promoting the preparation of iridium-192 sources to be used in brachytherapy, on a national level. (author)

  19. Perioperative interstitial brachytherapy for recurrent keloid scars

    International Nuclear Information System (INIS)

    Rio, E.; Bardet, E.; Peuvrel, P.; Martinet, L.; Perrot, P.; Baraer, F.; Loirat, Y.; Sartre, J.Y.; Malard, O.; Ferron, C.; Dreno, B.

    2010-01-01

    Purpose: Evaluation of the results of perioperative interstitial brachytherapy with low dose-rate (L.D.R.) Ir-192 in the treatment of keloid scars. Patients and methods: We performed a retrospective analysis of 73 histologically confirmed keloids (from 58 patients) resistant to medico surgical treated by surgical excision plus early perioperative brachytherapy. All lesions were initially symptomatic. Local control was evaluated by clinical evaluation. Functional and cosmetic results were assessed in terms of patient responses to a self-administered questionnaire. Results: Median age was 28 years (range 13-71 years). Scars were located as follows: 37% on the face, 32% on the trunk or abdomen, 16% on the neck, and 15% on the arms or legs. The mean delay before loading was four hours (range, 1-6 h). The median dose was 20 Gy (range, 15-40 Gy). Sixty-four scars (from 53 patients) were evaluated. Local control was 86% (follow-up, 44.5 months; range, 14-150 months). All relapses occurred early within 2 years posttreatment. At 20 months, survival without recurrence was significantly lower when treated lengths were more than 6 cm long. The rate was 100% for treated scars below 4.5 cm in length, 95% (95% CI: 55-96) for those 4.5-6 cm long, and 75% (95% CI: 56-88) beyond 6 cm (p = 0.038). Of the 35 scars (28 patients) whose results were reassessed, six remained symptomatic and the esthetic results were considered to be good in 51% (18/35) and average in 37% (13/35) (median follow-up, 70 months; range, 16-181 months). Conclusion: Early perioperative L.D.R. brachytherapy delivering 20 Gy at 5 mm reduced the rate of recurrent keloids resistant to other treatments and gave good functional results. (authors)

  20. High dose rate endobronchial brachytherapy - treatment technique

    International Nuclear Information System (INIS)

    Carvalho, Heloisa de Andrade; Aisen, Salim; Haddad, Cecilia Maria Kalil; Nadalin, Wladimir; Pedreira Junior, Wilson Leite; Chavantes, Maria Cristina

    1998-01-01

    High dose rate endobronchial brachytherapy is efficient in symptom relief due to obstructive endobronchial malignancies. However, it's role in survival improvement for patients with lung cancer is not yet established. The use of this treatment in increasing, specially in the developing countries. The purpose of this paper is to present the treatment technique used in the Radiotherapy Department of the Hospital da Clinicas, University of Sao Paulo, based on an experience of 60 cases treated with 180 procedures. Some practical suggestions and rules adopted in the Department are described. The severe complications rate is 6.7%, demonstrating an adequate patient selection associated with the technique utilized. (author)

  1. A study of Brachytherapy for Intraocular Tumor

    International Nuclear Information System (INIS)

    Ji, Kwang Soo; Yoo, Dae Hyun; Lee, Sung Goo; Kim, Jae Hu; Ji, Young Hun

    1996-01-01

    The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models. The result were as followed. 1. Eye model was determined as a 25 mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15 mm, 17 mm and 20 mm in diameter, and 1.5 mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5 mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ±10% and distance deviations are within 0.4 mm Maximum error is -11.3% and 0.8 mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192

  2. Development of a TLD mailed system for remote dosimetry audit for 192Ir HDR and PDR sources

    International Nuclear Information System (INIS)

    Roue, Amelie; Venselaar, Jack L.M.; Ferreira, Ivaldo H.; Bridier, Andre; Dam, Jan van

    2007-01-01

    Background and purpose: In the framework of an ESTRO ESQUIRE project, the BRAPHYQS Physics Network and the EQUAL-ESTRO laboratory have developed a procedure for checking the absorbed dose to water in the vicinity of HDR or PDR sources using a mailed TLD system. The methodology and the materials used in the procedure are based on the existing EQUAL-ESTRO external radiotherapy dose checks. Materials and methods: A phantom for TLD postal dose assurance service, adapted to accept catheters from different HDR afterloaders, has been developed. The phantom consists of three PMMA tubes supporting catheters placed at 120 degrees around a central TLD holder. A study on the use of LiF powder type DTL 937 (Philitech) has been performed in order to establish the TLD calibration in dose-to-water at a given distance from 192 Ir source, as well as to determine all correction factors to convert the TLD reading into absorbed dose to water. The dosimetric audit is based on the comparison between the dose to water measured with the TL dosimeter and the dose calculated by the clinical TPS. Results of the audits are classified in four different levels depending on the ratio of the measured dose to the stated dose. The total uncertainty budget in the measurement of the absorbed dose to water using TLD near an 192 Ir HDR source, including TLD reading, correction factors and TLD calibration coefficient, is determined as 3.27% (1 s). Results: To validate the procedures, the external audit was first tested among the members of the BRAPHYQS Network. Since November 2004, the test has been made available for use by all European brachytherapy centres. To date, 11 centres have participated in the checks and the results obtained are very encouraging. Nevertheless, one error detected has shown the usefulness of this audit. Conclusion: A method of absorbed dose to water determination in the vicinity of an 192 Ir brachytherapy source was developed for the purpose of a mailed TL dosimetry system. The

  3. Development of a TLD mailed system for remote dosimetry audit for (192)Ir HDR and PDR sources.

    Science.gov (United States)

    Roué, Amélie; Venselaar, Jack L M; Ferreira, Ivaldo H; Bridier, André; Van Dam, Jan

    2007-04-01

    In the framework of an ESTRO ESQUIRE project, the BRAPHYQS Physics Network and the EQUAL-ESTRO laboratory have developed a procedure for checking the absorbed dose to water in the vicinity of HDR or PDR sources using a mailed TLD system. The methodology and the materials used in the procedure are based on the existing EQUAL-ESTRO external radiotherapy dose checks. A phantom for TLD postal dose assurance service, adapted to accept catheters from different HDR afterloaders, has been developed. The phantom consists of three PMMA tubes supporting catheters placed at 120 degrees around a central TLD holder. A study on the use of LiF powder type DTL 937 (Philitech) has been performed in order to establish the TLD calibration in dose-to-water at a given distance from (192)Ir source, as well as to determine all correction factors to convert the TLD reading into absorbed dose to water. The dosimetric audit is based on the comparison between the dose to water measured with the TL dosimeter and the dose calculated by the clinical TPS. Results of the audits are classified in four different levels depending on the ratio of the measured dose to the stated dose. The total uncertainty budget in the measurement of the absorbed dose to water using TLD near an (192)Ir HDR source, including TLD reading, correction factors and TLD calibration coefficient, is determined as 3.27% (1s). To validate the procedures, the external audit was first tested among the members of the BRAPHYQS Network. Since November 2004, the test has been made available for use by all European brachytherapy centres. To date, 11 centres have participated in the checks and the results obtained are very encouraging. Nevertheless, one error detected has shown the usefulness of this audit. A method of absorbed dose to water determination in the vicinity of an (192)Ir brachytherapy source was developed for the purpose of a mailed TL dosimetry system. The accuracy of the procedure was determined. This method allows a

  4. High dose rate brachytherapy for superficial cancer of the esophagus

    International Nuclear Information System (INIS)

    Maingon, Philippe; D'Hombres, Anne; Truc, Gilles; Barillot, Isabelle; Michiels, Christophe; Bedenne, Laurent; Horiot, Jean Claude

    2000-01-01

    Purpose: We analyzed our experience with external radiotherapy, combined modality treatment, or HDR brachytherapy alone to limited esophageal cancers. Methods and Materials: From 1991 to 1996, 25 patients with limited superficial esophagus carcinomas were treated by high dose rate brachytherapy. The mean age was 63 years (43-86 years). Five patients showed superficial local recurrence after external radiotherapy. Eleven patients without invasion of the basal membrane were staged as Tis. Fourteen patients with tumors involving the submucosa without spreading to the muscle were staged as T1. Treatment consisted of HDR brachytherapy alone in 13 patients, external radiotherapy and brachytherapy in 8 cases, and concomitant chemo- and radiotherapy in 4 cases. External beam radiation was administered to a total dose of 50 Gy using 2 Gy daily fractions in 5 weeks. In cases of HDR brachytherapy alone (13 patients), 6 applications were performed once a week. Results: The mean follow-up is 31 months (range 24-96 months). Twelve patients received 2 applications and 13 patients received 6 applications. Twelve patients experienced a failure (48%), 11/12 located in the esophagus, all of them in the treated volume. One patient presented an isolated distant metastasis. In the patients treated for superficial recurrence, 4/5 were locally controlled (80%) by brachytherapy alone. After brachytherapy alone, 8/13 patients were controlled (61%). The mean disease-free survival is 14 months (1-36 months). Overall survival is 76% at 1 year, 37% at 2 years, and 14% at 3 years. Overall survival for Tis patients is 24% vs. 20% for T1 (p 0.83). Overall survival for patients treated by HDR brachytherapy alone is 43%. One patient presented with a fistula with local failure after external radiotherapy and brachytherapy. Four stenosis were registered, two were diagnosed on barium swallowing without symptoms, and two required dilatations. Conclusion: High dose rate brachytherapy permits the treating

  5. How to optimize therapeutic ratio in brachytherapy of head and neck squamous cell carcinoma?

    International Nuclear Information System (INIS)

    Mazeron, J.J.; Simon, J.M.; Hardiman, C.; Gerbaulet, A.

    1998-01-01

    Considerable experience has been accumulated with low dose rate (LDR) brachytherapy in the treatment of squamous cell carcinoma of the oral cavity and oropharynx, 4 cm or less in diameter. Recent analysis of large clinical series provided data indicating that modalities of LDR brachytherapy should be optimized in treating these tumours for increasing therapeutic ratio. LDR brachytherapy is now challenged by high dose rate (HDR) brachytherapy and pulsed dose rate (PDR) brachytherapy. Preliminary results obtained with the last two modalities are discussed in comparison with those achieved with LDR brachytherapy. (orig.)

  6. Coatings of nanoparticles applied to brachytherapy treatments

    International Nuclear Information System (INIS)

    Gonzalez, Andreza A.D.C.C.; Rostelato, Maria Elisa C.M.; Souza, Carla D.; Rodrigues, Bruna T.; Souza, Daiane C.B.; Zeituni, Carlos A.; Nogueira, Beatriz R.

    2017-01-01

    Brachytherapy is a treatment for cancer in which the radiation is placed close or in contact with the region to be treated saving the surrounding healthy tissues. Nanotechnology is the science that studies the properties of nanometric materials. Nanobrachytherapy in a new field that unites the advantages of brachytherapy with the small size in the nanoparticle, resulting in an even less invasive treatment. In view of the synthesis of the nanoparticles and their use, there is a fundamental role that is made by the coatings, which not only have the function of avoiding the aggregation of particles, but also stabilize and control their functional properties. Among the range of coatings, the most outstanding are polyethylene glycol (PEG) and gum arabica (GA). PEG improves the surface properties of nanoparticles and presents high stability under biomedical conditions. After the synthesis of gold nanoparticles was developed, PEG and gum arabica were successfully incorporated into the surface. In a vial of pyrex, 1 ml of coating agent and 1 ml of nanoparticles was left under gentle shaking for 2 hours. Incorporation was confirmed by DLS and HRTEM. GA requires further study. (author)

  7. Evaluation of resins for use in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Luiz Claudio F.M. Garcia; Ferraz, Wilmar Barbosa; Chrcanovic, Bruno Ramos; Santos, Ana Maria M., E-mail: ferrazw@cdtn.b, E-mail: amms@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Brachytherapy is an advanced cancer treatment where radioactive seeds or sources are placed near or directly into the tumor thus reducing the radiation exposure in the surrounding healthy tissues. Prostate cancer can be treated with interstitial brachytherapy in initial stage of the disease in which tiny radioactive seeds with cylindrical geometry are used. Several kinds of seeds have been developed in order to obtain a better dose distribution around them and with a lower cost manufacturing. These seeds consist of an encapsulation, a radionuclide carrier, and X-ray marker. Among the materials that have potential for innovation in the construction of seeds, biocompatible resins appear as an important option. In this paper, we present some characterization results with Fourier transform infrared spectroscopic (FTIR) and ultraviolet-visible spectroscopy (UV-vis) performed on two types of resins in which curing temperatures for each one were varied as also the results of coatings with these resins under titanium substrates. Interactions of these resins in contact with the simulated body fluid were evaluated by atomic force microscopy, scanning electron microscopy, and energy dispersive X-ray spectroscopy. (author)

  8. A study of brachytherapy for intraocular tumor

    International Nuclear Information System (INIS)

    Ji, Yung Hoon; Lee, Dong Han; Ko, Kyung Hwan; Lee, Tae Won; Lee, Sung Koo; Choi, Moon Sik

    1994-12-01

    Our purpose of this study is to perform brachytherapy for intraocular tumor. The result were as followed. 1. Eye model was determined as a 25 mm diameter sphere. Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15 mm, 17 mm and 20 mm in diameter, and 1.5 mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5 mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ±10% and distance deviations are within 0.4 mm. Maximum error is -11.3% and 0.8 mm, respectively. 7 figs, 2 tabs, 28 refs. (Author)

  9. Coatings of nanoparticles applied to brachytherapy treatments

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Andreza A.D.C.C.; Rostelato, Maria Elisa C.M.; Souza, Carla D.; Rodrigues, Bruna T.; Souza, Daiane C.B.; Zeituni, Carlos A.; Nogueira, Beatriz R., E-mail: ccg.andreza@gmail.com, E-mail: elisaros@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Brachytherapy is a treatment for cancer in which the radiation is placed close or in contact with the region to be treated saving the surrounding healthy tissues. Nanotechnology is the science that studies the properties of nanometric materials. Nanobrachytherapy in a new field that unites the advantages of brachytherapy with the small size in the nanoparticle, resulting in an even less invasive treatment. In view of the synthesis of the nanoparticles and their use, there is a fundamental role that is made by the coatings, which not only have the function of avoiding the aggregation of particles, but also stabilize and control their functional properties. Among the range of coatings, the most outstanding are polyethylene glycol (PEG) and gum arabica (GA). PEG improves the surface properties of nanoparticles and presents high stability under biomedical conditions. After the synthesis of gold nanoparticles was developed, PEG and gum arabica were successfully incorporated into the surface. In a vial of pyrex, 1 ml of coating agent and 1 ml of nanoparticles was left under gentle shaking for 2 hours. Incorporation was confirmed by DLS and HRTEM. GA requires further study. (author)

  10. The Activity Check of Brachytherapy Isotope

    International Nuclear Information System (INIS)

    Kim, Gun Oh; Lee, Byung Koo; Kwon, Young Ho

    2004-01-01

    An isotope Ir-192, which is used in brachytherapy depends on import in whole quantities. There are a few ways for its activity. measurement using Welltype chamber or the way to rely on authentic decay table of manufacturer. In-air dosimetry using Farmer Chamber, etc. In this paper, let me introduce the way using Farmer chamber which is easier and simple. With the Farmer chamber and source calibration jig, take a measurement the activity of an isotope Ir-192 and compare the value with the value from decay table of manufacturer and check the activity of source. The result of measurement, compared the value from decay table, by ±2.1. (which belongs to recommendable value for AAPM ±5% as difference of error range). It is possible to use on clinical medicine. With the increase in use of brachytherapy, the increase of import is essential. And an accurate activity check of source is compulsory. For the activity check of source, it was possible to use Farmer chamber and source calibration jig without additional purchase of Well type chamber.

  11. Problems of radiation protection and their solution in afterloading therapy performed in a X-ray deep therapy chamber of the Radiological Clinic of the Martin-Luther-University Halle

    International Nuclear Information System (INIS)

    Rauh, G.

    1982-01-01

    The Radiological Clinic of the Martin-Luther-University Halle got the first afterloading therapy unit DECATRON in December 1973. After preceding physical measurements the first patient was irradiated in August 1974. At this time there was no experience with the afterloading therapy in the GDR. The afterloading therapy was performed in a former X-ray deep therapy chamber. The occuring problems of radiation protection are considered and the ways of solution are described. Radiation protection calculations were carried out, values of local dose measurements are given, interpreted and compared with the values of personal dosimetry. Also the terms 'incorporated activity' and 'threading out activity' ('effective activity') are discussed, which led to differences in dose measurements formerly. The special situation required to discuss radiation protection problems of X-ray deep therapy simultaneously. (author)

  12. Radiotherapy and Brachytherapy : Proceedings of the NATO Advanced Study Institute on Physics of Modern Radiotherapy & Brachytherapy

    CERN Document Server

    Lemoigne, Yves

    2009-01-01

    This volume collects a series of lectures presented at the tenth ESI School held at Archamps (FR) in November 2007 and dedicated to radiotherapy and brachytherapy. The lectures focus on the multiple facets of radiotherapy in general, including external radiotherapy (often called teletherapy) as well as internal radiotherapy (called brachytherapy). Radiotherapy strategy and dose management as well as the decisive role of digital imaging in the associated clinical practice are developed in several articles. Grouped under the discipline of Conformal Radiotherapy (CRT), numerous modern techniques, from Multi-Leaf Collimators (MLC) to Intensity Modulated RadioTherapy (IMRT), are explained in detail. The importance of treatment planning based upon patient data from digital imaging (Computed Tomography) is also underlined. Finally, despite the quasi- totality of patients being presently treated with gamma and X-rays, novel powerful tools are emerging using proton and light ions (like carbon ions) beams, bound to bec...

  13. Brachytherapy. High dose rate brachytherapy - Radiation protection: medical sheet ED 4287

    International Nuclear Information System (INIS)

    Celier, D.; Aubert, B.; Vidal, J.P.; Biau, A.; Lahaye, T.; Gauron, C.; Barret, C.; Boisserie, G.; Branchet, E.; Gambini, D.; Gondran, C.; Le Guen, B.; Guerin, C.; Nguyen, S.; Pierrat, N.; Sarrazin, T.; Donnarieix, D.

    2010-02-01

    After having indicated the required authorization to implement brachytherapy techniques, this document presents the various aspects and measures related to radiation protection when performing high-dose-rate brachytherapy treatments. It presents the concerned personnel, describes the operational process, indicates the associated hazards and the risk related to ionizing radiation, and describes how the risk is to be assessed and how exposure levels are to be determined (elements of risk assessment, delimitation of controlled and monitored areas, personnel classification, and choice of the dose monitoring method). It describes the various components of a risk management strategy (risk reduction, technical measures regarding the installation and the personnel, training and information, prevention and medical monitoring). It briefly presents how risk management is to be assessed, and mentions other related risks (biological risk, handling and posture, handling of heavy loads, mental workload, chemical risk)

  14. Brachytherapy. Pulsed dose rate brachytherapy - Radiation protection: medical sheet ED 4250

    International Nuclear Information System (INIS)

    Celier, D.; Aubert, B.; Vidal, J.P.; Biau, A.; Lahaye, T.; Gauron, C.; Barret, C.; Boisserie, G.; Branchet, E.; Gambini, D.; Gondran, C.; Le Guen, B.; Guerin, C.; Nguyen, S.; Pierrat, N.; Sarrazin, T.; Donnarieix, D.

    2009-06-01

    After having indicated the required authorization to implement brachytherapy techniques, this document presents the various aspects and measures related to radiation protection when performing pulsed-dose-rate brachytherapy treatments. It presents the concerned personnel, describes the operational process, indicates the associated hazards and the risk related to ionizing radiation, and describes how the risk is to be assessed and how exposure levels are to be determined (elements of risk assessment, delimitation of controlled and monitored areas, personnel classification, and choice of the dose monitoring method). It describes the various components of a risk management strategy (risk reduction, technical measures regarding the installation and the personnel, training and information, prevention and medical monitoring). It briefly presents how risk management is to be assessed, and mentions other related risks (biological risk, handling and posture, handling of heavy loads, mental workload, chemical risk)

  15. Treatment of the prostate cancer with high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Martinez, Alvaro; Torres Silva, Felipe

    2002-01-01

    The prostate cancer treatment in early stages is controversial. The high dose rate brachytherapy has been used like monotherapy or boost with external beam radiotherapy in advanced disease. This paper describes the technique and the advantages over other modalities

  16. Manual on brachytherapy. Incorporating: Applications guide, procedures guide, basics guide

    International Nuclear Information System (INIS)

    1992-01-01

    In addition to a basic guide to the principles of the production of ionizing radiation and to methods of radiation protection and dosimetry, this booklet includes information about radiation protection procedures for brachytherapy

  17. Intra-luminal brachytherapy of bile duct tumors

    International Nuclear Information System (INIS)

    Udaya Kumar Maiya, M.; Bhat, Naresh; Praveen, L.S.

    2000-01-01

    The objective of this study has been to assess the feasibility of intraluminal brachytherapy of the biliary ductal system. The technique of the procedure with its attendant problems and how to overcome the same will be discussed in detail

  18. American Brachytherapy Society consensus report for accelerated partial breast irradiation using interstitial multicatheter brachytherapy.

    Science.gov (United States)

    Hepel, Jaroslaw T; Arthur, Douglas; Shaitelman, Simona; Polgár, Csaba; Todor, Dorin; Zoberi, Imran; Kamrava, Mitchell; Major, Tibor; Yashar, Catheryn; Wazer, David E

    To develop a consensus report for the quality practice of accelerated partial breast irradiation (APBI) using interstitial multicatheter brachytherapy (IMB). The American Brachytherapy Society Board appointed an expert panel with clinical and research experience with breast brachytherapy to provide guidance for the current practice of IMB. This report is based on a comprehensive literature review with emphasis on randomized data and expertise of the panel. Randomized trials have demonstrated equivalent efficacy of APBI using IMB compared with whole breast irradiation for select patients with early-stage breast cancer. Several techniques for placement of interstitial catheters are described, and importance of three-dimensional planning with appropriate optimization is reviewed. Optimal target definition is outlined. Commonly used dosing schemas include 50 Gy delivered in pulses of 0.6-0.8 Gy/h using pulsed-dose-rate technique and 34 Gy in 10 fractions, 32 Gy in eight fractions, or 30 Gy in seven fractions using high-dose-rate technique. Potential toxicities and strategies for toxicity avoidance are described in detail. Dosimetric constraints include limiting whole breast volume that receives ≥50% of prescription dose to 0.75 (>0.85 preferred), V 150  < 45 cc, and V 200  < 14 cc. Using an optimal implant technique coupled with optimal planning and appropriate dose constraints, a low rate of toxicity and a good-to-excellent cosmetic outcome of ≥90% is expected. IMB is an effective technique to deliver APBI for appropriately selected women with early-stage breast cancer. This consensus report has been created to assist clinicians in the appropriate practice of APBI using IMB. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  19. Resolving the brachytherapy challenges with government funded hospital.

    Science.gov (United States)

    Nikam, D S; Jagtap, A S; Vinothraj, R

    2016-01-01

    The objective of this study is to rationalize the feasibility and cost-effectiveness of high dose rate (HDR) cobalt 60 (Co-60) source versus 192-Iridium (192-Ir) source brachytherapy in government funded hospitals and treatment interruption gap because of exchange of sources. A retrospective study of gynecological cancer patients, treated by radiotherapy with curative intent between April 2005 and September 2012 was conducted. We analyzed the total number of patients treated for external beam radiotherapy (EBRT) and brachytherapy (Intracavitary brachytherapy or cylindrical vaginal source). The dates for 192-Ir sources installation and the last date and first date of brachytherapy procedure before and after source installation respectively were also analyzed and calculated the gap in days for brachytherapy interruptions. The study was analyzed the records of 2005 to September 2012 year where eight 192-Ir sources were installed. The mean gap between treatment interruptions was 123.12 days (range 1-647 days). The Institutional incidence of gynecological cancer where radiotherapy was treatment modality (except ovary) is 34.9 percent. Around 52.25 percent of patients who received EBRT at this institute were referred to outside hospital for brachytherapy because of unavailability of Iridium source. The cost for 5 year duration for single cobalt source is approximately 20-22 lakhs while for 15 Iridium sources is approximately 52-53 lakhs. The combined HDR Co-60 brachytherapy and EBRT provide a useful modality in the treatment of gynecological cancer where radiotherapy is indicated, the treatment interruption because of source exchange is longer and can be minimized by using cobalt source as it is cost-effective and has 5 year working life. Thus, Co-60 source for brachytherapy is a feasible option for government funded hospitals in developing countries.

  20. Review of advanced catheter technologies in radiation oncology brachytherapy procedures

    OpenAIRE

    Zhou J; Zamdborg L; Sebastian E

    2015-01-01

    Jun Zhou,1,2 Leonid Zamdborg,1 Evelyn Sebastian1 1Department of Radiation Oncology, Beaumont Health System, 2Oakland University William Beaumont School of Medicine, Royal Oak, MI, USA Abstract: The development of new catheter and applicator technologies in recent years has significantly improved treatment accuracy, efficiency, and outcomes in brachytherapy. In this paper, we review these advances, focusing on the performance of catheter imaging and reconstruction techniques in brachytherapy ...

  1. High versus low-dose rate brachytherapy for cervical cancer.

    Science.gov (United States)

    Patankar, Sonali S; Tergas, Ana I; Deutsch, Israel; Burke, William M; Hou, June Y; Ananth, Cande V; Huang, Yongmei; Neugut, Alfred I; Hershman, Dawn L; Wright, Jason D

    2015-03-01

    Brachytherapy plays an important role in the treatment of cervical cancer. While small trials have shown comparable survival outcomes between high (HDR) and low-dose rate (LDR) brachytherapy, little data is available in the US. We examined the utilization of HDR brachytherapy and analyzed the impact of type of brachytherapy on survival for cervical cancer. Women with stages IB2-IVA cervical cancer treated with primary (external beam and brachytherapy) radiotherapy between 2003-2011 and recorded in the National Cancer Database (NCDB) were analyzed. Generalized linear mixed models and Cox proportional hazards regression were used to examine predictors of HDR brachytherapy use and the association between HDR use and survival. A total of 10,564 women including 2681 (25.4%) who received LDR and 7883 (74.6%) that received HDR were identified. Use of HDR increased from 50.2% in 2003 to 83.9% in 2011 (Puse of HDR. While patients in the Northeast were more likely to receive HDR therapy, there were no other clinical or socioeconomic characteristics associated with receipt of HDR. In a multivariable Cox model, survival was similar between the HDR and LDR groups (HR=0.93; 95% CI 0.83-1.03). Similar findings were noted in analyses stratified by stage and histology. Kaplan-Meier analyses demonstrated no difference in survival based on type of brachytherapy for stage IIB (P=0.68), IIIB (P=0.17), or IVA (P=0.16) tumors. The use of HDR therapy has increased rapidly. Overall survival is similar for LDR and HDR brachytherapy. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Image-robot coupling for the prostate brachytherapy

    International Nuclear Information System (INIS)

    Coelen, V.; Lartigau, E.; Merzouki, R.

    2009-01-01

    The results allows to contemplate a robot use in the prostate brachytherapy but equally in other applications such prostate biopsy. The tests to come are going to be directed towards on the use of a prostate phantom in order to calibrate the ultrasonography. thereafter, we contemplate the conception of an intelligent gripping system placed on the robot arm and allowing a good control in closed loop of the brachytherapy needle placement and allowing the setting up of an online monitoring. (N.C.)

  3. MO-B-BRC-01: Introduction [Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Prisciandaro, J. [University of Michigan (United States)

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  4. Electronic brachytherapy management of atypical fibroxanthoma: report of 8 lesions

    Directory of Open Access Journals (Sweden)

    Stephen Doggett

    2017-01-01

    Full Text Available Purpose : To evaluate the suitability of treating atypical fibroxanthoma (AFX, an uncommon skin malignancy, with electronic brachytherapy. Material and methods : From Feb 2013 to Sep 2014, we were referred a total of 8 cases of AFX in 7 patients, all involving the scalp. All of them were treated with electronic brachytherapy 50 Kev radiations (Xoft Axxent®, Fremont, California. All lesions received 40 Gy in two fractions per week with 5mm margins. Results : At a median follow-up of 23.7 months, the local recurrence rate is 12.5%. The single lesion that failed was not debulked surgically prior to electronic brachytherapy. Conclusions : To our knowledge, this is the first report in the literature on the use of radiation therapy as curative primary treatment for AFX. No contraindication to the use of radiations is found in the literature, with surgery being the sole treatment for AFX noted. Our recurrence rate is 0% for debulked lesions. Risk of recurrence is mitigated with surgical debulking prior to brachytherapy. Electronic brachytherapy appears to be a safe and effective treatment for debulked AFX. Multiple excisions, skin grafting, and wound care can be avoided in elderly patients by the use of electronic brachytherapy.

  5. Role of brachytherapy in the treatment of localized prostate cancer

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2015-01-01

    Full Text Available The review is devoted to application of brachytherapy for treating the localized prostate cancer (PC. Statistics for incidence and detectability of this pathology and its dynamics for recent years are represented. Brief analysis of other methods which are conveniently used for treatment of PC, such as radical prostatectomy and external-beam radiotherapy, was performed. Advantages and disadvantages of these methods have been discussed. Brief history about the development of brachytherapy from first experience to wide-spread use in clinical practice is reported. The detailed review of series of large trials from Russia and other countries for efficiency and safety of brachytherapy in patients with prostate cancer for recent 15 years is also represented. Two types of brachytherapy in current clinical oncology i.e. low-dose technique with permanent implantation of microsources and high-dose temporary isotope implantation, specifics of its application in different groups of patients have been described. The procedure of brachytherapy and its three main steps i.e. planning, implantation and control assessment after implantation have been characterized in details. The conclusion about benefits of using of brachytherapy in the treatment of prostate cancer as minimally invasive and efficient method was made. 

  6. Overview of brachytherapy resources in Europe: A survey of patterns of care study for brachytherapy in Europe

    International Nuclear Information System (INIS)

    Guedea, Ferran; Ellison, Tracey; Venselaar, Jack; Borras, Josep Maria; Hoskin, Peter; Poetter, Richard; Heeren, Germaine; Nisin, Roselinne; Francois, Guy; Mazeron, Jean Jacques; Limbergen, Erik Van; Ventura, Montserrat; Taillet, Michel; Cottier, Brian

    2007-01-01

    Background and purpose: The Patterns of Care for Brachytherapy in Europe (PCBE) study is aimed at establishing a detailed information system on brachytherapy throughout Europe. Materials and methods: The questionnaire was web-based and the analysis used data from each radiotherapy department with brachytherapy. There were three groups: Group I with 19 countries (15 initial European Community (EC) countries plus Iceland, Monaco, Norway and Switzerland -EC+4-), Group II with 10 countries (New European Community countries -NEC-) and Group III with 14 countries (Other European Countries -OEC-). Results: In the European area there are 36 of 43 countries (85%) which achieved data collection from at least 50% of centres, and were included in the analysis. The tumour site that had the largest number of treated patients was gynaecological tumours. Several variations have been found in the mean number of patients treated per consultant radiation oncologist and physicist; and in the proportion of brachytherapy patients with gynaecology, prostate and breast tumours, by country and by European area. The provided data showed that the average number of brachytherapy patients per centre increased by 10% between 1997 and 2002. Conclusions: A European wide evaluation of brachytherapy practice using a web-based questionnaire is feasible and that there is considerable variation in both patterns of practice and available resources

  7. Influence of Distal Resistance and Proximal Stiffness on Hemodynamics and RV Afterload in Progression and Treatments of Pulmonary Hypertension: A Computational Study with Validation Using Animal Models

    Directory of Open Access Journals (Sweden)

    Zhenbi Su

    2013-01-01

    Full Text Available We develop a simple computational model based on measurements from a hypoxic neonatal calf model of pulmonary hypertension (PH to investigate the interplay between vascular and ventricular measures in the setting of progressive PH. Model parameters were obtained directly from in vivo and ex vivo measurements of neonatal calves. Seventeen sets of model-predicted impedance and mean pulmonary arterial pressure (mPAP show good agreement with the animal measurements, thereby validating the model. Next, we considered a predictive model in which three parameters, PVR, elastic modulus (EM, and arterial thickness, were varied singly from one simulation to the next to study their individual roles in PH progression. Finally, we used the model to predict the individual impacts of clinical (vasodilatory and theoretical (compliance increasing PH treatments on improving pulmonary hemodynamics. Our model (1 displayed excellent patient-specific agreement with measured global pulmonary parameters; (2 quantified relationships between PVR and mean pressure and PVS and pulse pressure, as well as studiying the right ventricular (RV afterload, which could be measured as a hydraulic load calculated from spectral analysis of pulmonary artery pressure and flow waves; (3 qualitatively confirmed the derangement of vascular wall shear stress in progressive PH; and (4 established that decreasing proximal vascular stiffness through a theoretical treatment of reversing proximal vascular remodeling could decrease RV afterload.

  8. Remote viewing.

    Science.gov (United States)

    Scott, C

    1988-04-15

    Remote viewing is the supposed faculty which enables a percipient, sited in a closed room, to describe the perceptions of a remote agent visiting an unknown target site. To provide convincing demonstration of such a faculty poses a range of experimental and practical problems, especially if feedback to the percipient is allowed after each trial. The precautions needed are elaborate and troublesome; many potential loopholes have to be plugged and there will be strong temptations to relax standards, requiring exceptional discipline and dedication by the experimenters. Most reports of remote viewing experiments are rather superficial and do not permit assessment of the experimental procedures with confidence; in many cases there is clear evidence of particular loopholes left unclosed. Any serious appraisal of the evidence would have to go beyond the reports. Meanwhile the published evidence is far from compelling, and certainly insufficient to justify overthrow of well-established scientific principles.

  9. Paddle-based rotating-shield brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yunlong; Xu, Weiyu [Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center, Iowa City, Iowa 52242 (United States); Flynn, Ryan T.; Kim, Yusung; Bhatia, Sudershan K.; Buatti, John M. [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States); Dadkhah, Hossein [Department of Biomedical Engineering, University of Iowa, 1402 Seamans Center, Iowa City, Iowa 52242 (United States); Wu, Xiaodong, E-mail: xiaodong-wu@uiowa.edu [Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center, Iowa City, Iowa 52242 and Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States)

    2015-10-15

    Purpose: The authors present a novel paddle-based rotating-shield brachytherapy (P-RSBT) method, whose radiation-attenuating shields are formed with a multileaf collimator (MLC), consisting of retractable paddles, to achieve intensity modulation in high-dose-rate brachytherapy. Methods: Five cervical cancer patients using an intrauterine tandem applicator were considered to assess the potential benefit of the P-RSBT method. The P-RSBT source used was a 50 kV electronic brachytherapy source (Xoft Axxent™). The paddles can be retracted independently to form multiple emission windows around the source for radiation delivery. The MLC was assumed to be rotatable. P-RSBT treatment plans were generated using the asymmetric dose–volume optimization with smoothness control method [Liu et al., Med. Phys. 41(11), 111709 (11pp.) (2014)] with a delivery time constraint, different paddle sizes, and different rotation strides. The number of treatment fractions (fx) was assumed to be five. As brachytherapy is delivered as a boost for cervical cancer, the dose distribution for each case includes the dose from external beam radiotherapy as well, which is 45 Gy in 25 fx. The high-risk clinical target volume (HR-CTV) doses were escalated until the minimum dose to the hottest 2 cm{sup 3} (D{sub 2cm{sup 3}}) of either the rectum, sigmoid colon, or bladder reached their tolerance doses of 75, 75, and 90 Gy{sub 3}, respectively, expressed as equivalent doses in 2 Gy fractions (EQD2 with α/β = 3 Gy). Results: P-RSBT outperformed the two other RSBT delivery techniques, single-shield RSBT (S-RSBT) and dynamic-shield RSBT (D-RSBT), with a properly selected paddle size. If the paddle size was angled at 60°, the average D{sub 90} increases for the delivery plans by P-RSBT on the five cases, compared to S-RSBT, were 2.2, 8.3, 12.6, 11.9, and 9.1 Gy{sub 10}, respectively, with delivery times of 10, 15, 20, 25, and 30 min/fx. The increases in HR-CTV D{sub 90}, compared to D-RSBT, were 16

  10. An overview of interstitial brachytherapy and hyperthermia

    International Nuclear Information System (INIS)

    Brandt, B.B.; Harney, J.

    1989-01-01

    Interstitial thermoradiotherapy, an experimental cancer treatment that combines interstitial radiation implants (brachytherapy) and interstitial hyperthermia, is in the early stages of investigation. In accordance with the procedure used in a current national trial protocol, a 60-minute hyperthermia treatment is administered after catheters are placed into the tumor area while the patient is under general anesthesia. This is immediately followed by loading of radioactive Iridium-192 seeds into the catheters for a defined period of time. Once the prescribed radiation dose is delivered, the radioactive sources are removed and a second, 60-minute hyperthermia treatment is administered. Clinical trials with hyperthermia in combination with radiation have increased in recent years. Nurses caring for these patients need to become more knowledgeable about this investigational therapy. This paper provides an overview of the biologic rationale for this therapy, as well as a description of the delivery method and clinical application. Specific related nursing interventions are defined in a nursing protocol.23 references

  11. Epoxy resins used to seal brachytherapy seed

    International Nuclear Information System (INIS)

    Ferreira, Natalia Carolina Camargos; Ferraz, Wilmar Barbosa; Reis, Sergio Carneiro dos; Santos, Ana Maria Matildes dos

    2013-01-01

    Prostate cancer treatment with brachytherapy is recommended for patients with cancer at an early stage. In this treatment, small radioactive seeds are implanted directly in the prostate gland. These seeds are composed at least of one radionuclide carrier and an X-ray marker enclosed within a metallic tube usually sealed by laser process. This process is expensive and, furthermore, it can provoke a partial volatilization of the radionuclide and change the isotropy in dose distribution around the seed. In this paper, we present a new sealing process using epoxy resin. Three kinds of resins were utilized and characterized by scanning electron microscopy (SEM), energy dispersive X ray (EDS) and by differential scanning calorimetry (DSC) after immersion in simulated body fluid (SBF) and in sodium iodine solution (NaI). The sealing process showed excellent potential to replace the sealing laser usually employed. (author)

  12. Calibration of Photon Sources for Brachytherapy

    Science.gov (United States)

    Rijnders, Alex

    Source calibration has to be considered an essential part of the quality assurance program in a brachytherapy department. Not only it will ensure that the source strength value used for dose calculation agrees within some predetermined limits to the value stated on the source certificate, but also it will ensure traceability to international standards. At present calibration is most often still given in terms of reference air kerma rate, although calibration in terms of absorbed dose to water would be closer to the users interest. It can be expected that in a near future several standard laboratories will be able to offer this latter service, and dosimetry protocols will have to be adapted in this way. In-air measurement using ionization chambers (e.g. a Baldwin—Farmer ionization chamber for 192Ir high dose rate HDR or pulsed dose rate PDR sources) is still considered the method of choice for high energy source calibration, but because of their ease of use and reliability well type chambers are becoming more popular and are nowadays often recommended as the standard equipment. For low energy sources well type chambers are in practice the only equipment available for calibration. Care should be taken that the chamber is calibrated at the standard laboratory for the same source type and model as used in the clinic, and using the same measurement conditions and setup. Several standard laboratories have difficulties to provide these calibration facilities, especially for the low energy seed sources (125I and 103Pd). Should a user not be able to obtain properly calibrated equipment to verify the brachytherapy sources used in his department, then at least for sources that are replaced on a regular basis, a consistency check program should be set up to ensure a minimal level of quality control before these sources are used for patient treatment.

  13. Methods for prostate stabilization during transperineal LDR brachytherapy

    International Nuclear Information System (INIS)

    Podder, Tarun; Yu Yan; Sherman, Jason; Rubens, Deborah; Strang, John; Messing, Edward; Ng, Wan-Sing

    2008-01-01

    In traditional prostate brachytherapy procedures for a low-dose-rate (LDR) radiation seed implant, stabilizing needles are first inserted to provide some rigidity and support to the prostate. Ideally this will provide better seed placement and an overall improved treatment. However, there is much speculation regarding the effectiveness of using regular brachytherapy needles as stabilizers. In this study, we explored the efficacy of two types of needle geometries (regular brachytherapy needle and hooked needle) and several clinically feasible configurations of the stabilization needles. To understand and assess the prostate movement during seed implantation, we collected in vivo data from patients during actual brachytherapy procedures. In vitro experimentation with tissue-equivalent phantoms allowed us to further understand the mechanics behind prostate stabilization. We observed superior stabilization with the hooked needles compared to the regular brachytherapy needles (more than 40% in bilateral parallel needle configuration). Prostate movement was also reduced significantly when regular brachytherapy needles were in an angulated configuration as compared to the parallel configuration (more than 60%). When the hooked needles were angulated for stabilization, further reduction in prostate displacement was observed. In general, for convenience of dosimetric planning and to avoid needle collision, all needles are desired to be in a parallel configuration. In this configuration, hooked needles provide improved stabilization of the prostate. On the other hand, both regular and hooked needles appear to be equally effective in reducing prostate movement when they are in angulated configurations, which will be useful in seed implantation using a robotic system. We have developed nonlinear spring-damper model for the prostate movement which can be used for adapting dosimetric planning during brachytherapy as well as for developing more realistic haptic devices and

  14. National audit of a system for rectal contact brachytherapy

    Directory of Open Access Journals (Sweden)

    Laia Humbert-Vidan

    2017-01-01

    Full Text Available Background and purpose: Contact brachytherapy is used for the treatment of early rectal cancer. An overview of the current status of quality assurance of the rectal contact brachytherapy systems in the UK, based on a national audit, was undertaken in order to assist users in optimising their own practices. Material and methods: Four UK centres using the Papillon 50 contact brachytherapy system were audited. Measurements included beam quality, output and radiation field size and uniformity. Test frequencies and tolerances were reviewed and compared to both existing recommendations and published reviews on other kV and electronic brachytherapy systems. External validation of dosimetric measurements was provided by the National Physical Laboratory. Results: The maximum host/audit discrepancy in beam quality determination was 6.5%; this resulted in absorbed dose variations of 0.2%. The host/audit agreement in absorbed dose determination was within 2.2%. The median of the radiation field uniformity measurements was 2.7% and the host/audit agreement in field size was within 1 mm. Test tolerances and frequencies were within the national recommendations for kV units. Conclusions: The dosimetric characterisation of the Papillon 50 was validated by the audit measurements for all participating centres, thus providing reassurance that the implementation had been performed within the standards stated in previously published audit work and recommendations for kV and electronic brachytherapy units. However, optimised and standardised quality assurance testing could be achieved by reducing some methodological differences observed. Keywords: Contact brachytherapy, Electronic brachytherapy, Audit

  15. Methods for prostate stabilization during transperineal LDR brachytherapy.

    Science.gov (United States)

    Podder, Tarun; Sherman, Jason; Rubens, Deborah; Messing, Edward; Strang, John; Ng, Wan-Sing; Yu, Yan

    2008-03-21

    In traditional prostate brachytherapy procedures for a low-dose-rate (LDR) radiation seed implant, stabilizing needles are first inserted to provide some rigidity and support to the prostate. Ideally this will provide better seed placement and an overall improved treatment. However, there is much speculation regarding the effectiveness of using regular brachytherapy needles as stabilizers. In this study, we explored the efficacy of two types of needle geometries (regular brachytherapy needle and hooked needle) and several clinically feasible configurations of the stabilization needles. To understand and assess the prostate movement during seed implantation, we collected in vivo data from patients during actual brachytherapy procedures. In vitro experimentation with tissue-equivalent phantoms allowed us to further understand the mechanics behind prostate stabilization. We observed superior stabilization with the hooked needles compared to the regular brachytherapy needles (more than 40% in bilateral parallel needle configuration). Prostate movement was also reduced significantly when regular brachytherapy needles were in an angulated configuration as compared to the parallel configuration (more than 60%). When the hooked needles were angulated for stabilization, further reduction in prostate displacement was observed. In general, for convenience of dosimetric planning and to avoid needle collision, all needles are desired to be in a parallel configuration. In this configuration, hooked needles provide improved stabilization of the prostate. On the other hand, both regular and hooked needles appear to be equally effective in reducing prostate movement when they are in angulated configurations, which will be useful in seed implantation using a robotic system. We have developed nonlinear spring-damper model for the prostate movement which can be used for adapting dosimetric planning during brachytherapy as well as for developing more realistic haptic devices and

  16. The American brachytherapy society survey of brachytherapy practice for carcinoma of the cervix in the United States.

    Science.gov (United States)

    Nag, S; Orton, C; Young, D; Erickson, B

    1999-04-01

    The purpose of this study was to survey the brachytherapy practice for cervical cancer in the United States. The Clinical Research Committee of the American Brachytherapy Society (ABS) performed a retrospective survey of individual physicians of the ABS and American Society of Therapeutic Radiologists and Oncologists regarding the details of the brachytherapy techniques they personally used in the treatment of cervical cancer patients for the year 1995. The replies (some of which may have been an estimate only) were tabulated. The scope of this survey did not allow us to verify the data by chart audits. A total of about 3500 questionnaires were mailed out; 521 responses were received. Of these responders, 206 (40%) did not perform any brachytherapy for carcinoma of the cervix in 1995. Of the other 315 responders reporting a total of 4892 patients treated in 1995, 88% used low dose rate (LDR) while 24% used high dose rate (HDR). There was a wide variation in the doses used. For LDR treatments, the median total external beam radiation therapy (EBRT) dose was 45 and 50 Gy and the LDR dose was 42 and 45 Gy for early and advanced cancers, respectively. For HDR treatments, the median EBRT dose was 48 and 50 Gy and the median HDR dose was 29 and 30 Gy for early and advanced cancers, respectively. The median dose per fraction was 6 Gy for a median of five fractions. Interstitial brachytherapy was used as a component of the treatment in 6% of the patients by 21% of responders. Very few responders treated with pulsed or medium dose rates. This retrospective survey showed the current brachytherapy practice pattern in the treatment of cervical cancer in the United States and can serve as a basis for future prospective national brachytherapy data registry. There was wide variation in the practice pattern, emphasizing the urgent need for consensus on these issues. Copyright 1999 Academic Press.

  17. Utilization and Outcomes of Breast Brachytherapy in Younger Women

    International Nuclear Information System (INIS)

    Smith, Grace L.; Huo, Jinhai; Giordano, Sharon H.; Hunt, Kelly K.; Buchholz, Thomas A.; Smith, Benjamin D.

    2015-01-01

    Purpose: To directly compare (1) radiation treatment utilization patterns; (2) risks of subsequent mastectomy; and (3) costs of radiation treatment in patients treated with brachytherapy versus whole-breast irradiation (WBI), in a national, contemporary cohort of women with incident breast cancer, aged 64 years and younger. Methods and Materials: Using MarketScan health care claims data, we identified 45,884 invasive breast cancer patients (aged 18-64 years), treated from 2003 to 2010 with lumpectomy, followed by brachytherapy (n=3134) or whole-breast irradiation (n=42,750). We stratified patients into risk groups according to age (Age<50 vs Age≥50) and endocrine therapy status (Endocrine− vs Endocrine+). “Endocrine+” patients filled an endocrine therapy prescription within 1 year after lumpectomy. Pathologic hormone receptor status was not available in this dataset. In brachytherapy versus WBI patients, utilization trends and 5-year subsequent mastectomy risks were compared. Stratified, adjusted subsequent mastectomy risks were calculated using proportional hazards regression. Results: Brachytherapy utilization increased from 2003 to 2010: in patients Age<50, from 0.6% to 4.9%; patients Age≥50 from 2.2% to 11.3%; Endocrine− patients, 1.3% to 9.4%; Endocrine+ patients, 1.9% to 9.7%. Age influenced treatment selection more than endocrine status: 17% of brachytherapy patients were Age<50 versus 32% of WBI patients (P<.001); whereas 41% of brachytherapy patients were Endocrine–versus 44% of WBI patients (P=.003). Highest absolute 5-year subsequent mastectomy risks occurred in Endocrine−/Age<50 patients (24.4% after brachytherapy vs 9.0% after WBI (hazard ratio [HR] 2.18, 95% confidence interval [CI] 1.37-3.47); intermediate risks in Endocrine−/Age≥50 patients (8.6% vs 4.9%; HR 1.76, 95% CI 1.26-2.46); and lowest risks in Endocrine+ patients of any age: Endocrine+/Age<50 (5.5% vs 4.5%; HR 1.18, 95% CI 0.61-2.31); Endocrine+/Age≥50 (4.2% vs 2

  18. Utilization and Outcomes of Breast Brachytherapy in Younger Women

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Grace L. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Huo, Jinhai [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Giordano, Sharon H. [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Hunt, Kelly K. [Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Buchholz, Thomas A. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Smith, Benjamin D., E-mail: bsmith3@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2015-09-01

    Purpose: To directly compare (1) radiation treatment utilization patterns; (2) risks of subsequent mastectomy; and (3) costs of radiation treatment in patients treated with brachytherapy versus whole-breast irradiation (WBI), in a national, contemporary cohort of women with incident breast cancer, aged 64 years and younger. Methods and Materials: Using MarketScan health care claims data, we identified 45,884 invasive breast cancer patients (aged 18-64 years), treated from 2003 to 2010 with lumpectomy, followed by brachytherapy (n=3134) or whole-breast irradiation (n=42,750). We stratified patients into risk groups according to age (Age<50 vs Age≥50) and endocrine therapy status (Endocrine− vs Endocrine+). “Endocrine+” patients filled an endocrine therapy prescription within 1 year after lumpectomy. Pathologic hormone receptor status was not available in this dataset. In brachytherapy versus WBI patients, utilization trends and 5-year subsequent mastectomy risks were compared. Stratified, adjusted subsequent mastectomy risks were calculated using proportional hazards regression. Results: Brachytherapy utilization increased from 2003 to 2010: in patients Age<50, from 0.6% to 4.9%; patients Age≥50 from 2.2% to 11.3%; Endocrine− patients, 1.3% to 9.4%; Endocrine+ patients, 1.9% to 9.7%. Age influenced treatment selection more than endocrine status: 17% of brachytherapy patients were Age<50 versus 32% of WBI patients (P<.001); whereas 41% of brachytherapy patients were Endocrine–versus 44% of WBI patients (P=.003). Highest absolute 5-year subsequent mastectomy risks occurred in Endocrine−/Age<50 patients (24.4% after brachytherapy vs 9.0% after WBI (hazard ratio [HR] 2.18, 95% confidence interval [CI] 1.37-3.47); intermediate risks in Endocrine−/Age≥50 patients (8.6% vs 4.9%; HR 1.76, 95% CI 1.26-2.46); and lowest risks in Endocrine+ patients of any age: Endocrine+/Age<50 (5.5% vs 4.5%; HR 1.18, 95% CI 0.61-2.31); Endocrine+/Age≥50 (4.2% vs 2

  19. Construction balance analysis of dose rate medium brachytherapy TDS

    International Nuclear Information System (INIS)

    Sandi Parapak

    2011-01-01

    One of the most important part of brachytherapy instrument design activities is analyze by determining the centroid point of construction in order to maintain the balance of brachytherapy instrument, either during operation as well as when transported. Operation of brachytherapy is not only done in one place so it is necessary to balance the analysis of the forces at the time did not move, moved on the horizontal floor and sloping floor. Calculation approach who is done to calculate the weight of mechanical components on each module, and then calculate the centroid of each module, for the balance of forces analysis performed with the assumption at the time of brachytherapy in the position of not moving on a horizontal floor, moved from a place to another on the horizontal floor and on the floor with sloping angle 30°. Base on the results of this analysis are expected to balance the four wheels can move without slipping at the time of decline or incline. Also, results of analysis can be used in designing a mobile construction brachytherapy taking into consideration the aesthetic ideal, easy to operate, ensure the safety of equipment, operator and patient. (author)

  20. High dose rate brachytherapy for the palliation of malignant dysphagia

    International Nuclear Information System (INIS)

    Homs, Marjolein Y.V.; Eijkenboom, Wilhelmina M.H.; Coen, Veronique L.M.A.; Haringsma, Jelle; Blankenstein, Mark van; Kuipers, Ernst J.; Siersema, Peter D.

    2003-01-01

    Background and purpose: High dose rate (HDR) brachytherapy is a commonly used palliative treatment for esophageal carcinoma. We evaluated the outcome of HDR brachytherapy in patients with malignant dysphagia. Material and methods: A retrospective analysis over a 10-year period was performed of 149 patients treated with HDR brachytherapy, administered in one or two sessions, at a median dose of 15 Gy. Patients were evaluated for functional outcome, complications, recurrent dysphagia, and survival. Results: At 6 weeks after HDR brachytherapy, dysphagia scores had improved from a median of 3 to 2 (n=104; P<0.001), however, dysphagia had not improved in 51 (49%) patients. Procedure-related complications occurred in seven (5%) patients. Late complications, including fistula formation or bleeding, occurred in 11 (7%) patients. Twelve (8%) patients experienced minor retrosternal pain. Median survival of the patients was 160 days with a 1-year survival rate of 15%. Procedure-related mortality was 2%. At follow-up, 55 (37%) patients experienced recurrent dysphagia. In 34 (23%) patients a metal stent was placed to relieve persistent or recurrent dysphagia. Conclusion: HDR brachytherapy is a moderately effective treatment for the palliation of malignant dysphagia. The incidence of early major complications is low, however, persistent and recurrent dysphagia occur frequently, and require often additional treatment

  1. Brachytherapy - not pulsed and low rate brachytherapy. Medical radiation protection - ED 4248

    International Nuclear Information System (INIS)

    2008-06-01

    After an indication of authorizations required to perform brachytherapy, this sheet indicates the concerned personnel, indicates the different treatment steps, briefly describes the risk related to ionizing radiations, indicates the various aspects of risk assessment and of determination of exposure levels (definition of controlled and monitored areas, personnel classification, possible methods for dose monitoring), presents the strategy for risk management (rules regarding risk reduction, technical measures regarding the installation, individual technical measures, training and information, prevention and medical monitoring) and how this risk management can be assessed

  2. The monetary value of the man.rem and optimization in radiation therapy (brachytherapy)

    International Nuclear Information System (INIS)

    Ennow, K.R.; Jessen, K.A.

    1979-01-01

    The personnel exposed by sources used for intracavitary radiation therapy in Denmark receive more than 40% of the collective dose recorded by personal dosemeters in Denmark. As the application of after-loading technique has become generally accepted by the medical profession in Denmark as a replacement to a considerable degree for manual radium therapy, the most promising suggestion for reduction of radiation doses is the introduction of after-loading facilities in all radiation therapy centres. Such facilities are now being planned in Denmark but their realization will entail great expense and therefore the financial aspects of these plans will be very important. At present the advantage of after-loading cannot be simply demonstrated to the politicians holding the purse strings, i.e. in terms of improved therapeutical gain, e.g. increased survival, although the incidence of complications has been shown to be lower, but the reduction in personnel radiation doses by the change to after-loading will be evident and be an important part of the cost-benefit analysis. By detailed investigation of all expenditures and savings, cost-benefit analysis has been carried out in order to isolate the relationship between expense and the collective dose reduction. If after-loading facilities are established in Denmark today with the intention of reducing the risk for employees and without any expectation of improvements in treatment, the monetary value of the man.rem implied is 10,000 kr. or 2000 US dollars. (author)

  3. A survey of current clinical practice in permanent and temporary prostate brachytherapy: 2010 update.

    Science.gov (United States)

    Buyyounouski, Mark K; Davis, Brian J; Prestidge, Bradley R; Shanahan, Thomas G; Stock, Richard G; Grimm, Peter D; Demanes, D Jeffrey; Zaider, Marco; Horwitz, Eric M

    2012-01-01

    To help establish patterns of care and standards of care of interstitial permanent low-dose-rate (LDR) and temporary high-dose-rate brachytherapy for prostate cancer and to compare the results with a similar 1998 American Brachytherapy Society (ABS) survey. A comprehensive questionnaire intended to survey specific details of current clinical brachytherapy practice was provided to the participants of the seventh ABS Prostate Brachytherapy School. Responses were tabulated and descriptive statistics are reported. Sixty-five brachytherapy practitioners responded to the survey. Eighty-nine percent (89%) of respondents performed LDR and 49% perform high-dose-rate brachytherapy. The median number of years of experience for LDR brachytherapists increased from 5 to 10 years over the course of the 12 years since the preceding survey. Compared with the first ABS, a smaller proportion of respondents received formal brachytherapy residency training (43% vs. 56%) or formal "hands-on" brachytherapy training (15% vs. 63%). There has been a marked decline in the utilization of the Mick applicator (Mick Radio-Nuclear Instruments, Inc., Mount Vernon, NY, USA) (60% vs. 28%) and an increase in the use of stranded seeds (40% vs. 11%). Compliance with postimplant dosimetry was higher in the 2010 survey. This survey does suggest an evolution in the practice of LDR brachytherapy since 1998 and aids in identifying aspects that require further progress or investigation. ABS guidelines and other practice recommendations appear to impact the practice of brachytherapy. Copyright © 2012 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  4. Standardization of prostate brachytherapy treatment plans

    International Nuclear Information System (INIS)

    Ove, Roger; Wallner, Kent; Badiozamani, Kas; Korjsseon, Tammy; Sutlief, Steven

    2001-01-01

    Purpose: Whereas custom-designed plans are the norm for prostate brachytherapy, the relationship between linear prostate dimensions and volume calls into question the routine need for customized treatment planning. With the goal of streamlining the treatment-planning process, we have compared the treatment margins (TMs) achieved with one standard plan applied to patients with a wide range of prostate volumes. Methods and Materials: Preimplant transrectal ultrasound (TRUS) images of 50 unselected University of Washington patients with T1-T2 cancer and a prostate volume between 20 cc and 50 cc were studied. Patients were arbitrarily grouped into categories of 20-30 cc, 30-40 cc, and 40-50 cc. A standard 19-needle plan was devised for patients in the 30- to 40-cc range, using an arbitrary minimum margin of 5 mm around the gross tumor volume (GTV), making use of inverse planning technology to achieve 100% coverage of the target volume with accentuation of dose at the periphery and sparing of the central region. The idealized plan was applied to each patient's TRUS study. The distances (TMs) between the prostatic edge (GTV) and treated volume (TV) were determined perpendicular to the prostatic margin. Results: Averaged over the entire patient group, the ratio of thickness to width was 1.4, whereas the ratio of length to width was 1.3. These values were fairly constant over the range of volumes, emphasizing that the prostate retains its general shape as volume increases. The idealized standard plan was overlaid on the ultrasound images of the 17 patients in the 30- to 40-cc group and the V100, the percentage of target volume receiving 100% or more of the prescription dose, was 98% or greater for 15 of the 17 patients. The lateral and posterior TMs fell within a narrow range, most being within 2 mm of the idealized 5-mm TM. To estimate whether a 10-cc volume-interval stratification was reasonable, the standard plan generated from the 30- to 40-cc prostate model was

  5. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: an electronic brachytherapy source.

    Science.gov (United States)

    Rivard, Mark J; Davis, Stephen D; DeWerd, Larry A; Rusch, Thomas W; Axelrod, Steve

    2006-11-01

    A new x-ray source, the model S700 Axxent X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, S700 Source exhibited depth dose behavior similar to low-energy photon-emitting low dose rate sources 125I and l03Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages.

  6. Interstitial rotating shield brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Adams, Quentin E.; Xu, Jinghzu; Breitbach, Elizabeth K.; Li, Xing; Rockey, William R.; Kim, Yusung; Wu, Xiaodong; Flynn, Ryan T.; Enger, Shirin A.

    2014-01-01

    Purpose: To present a novel needle, catheter, and radiation source system for interstitial rotating shield brachytherapy (I-RSBT) of the prostate. I-RSBT is a promising technique for reducing urethra, rectum, and bladder dose relative to conventional interstitial high-dose-rate brachytherapy (HDR-BT). Methods: A wire-mounted 62 GBq 153 Gd source is proposed with an encapsulated diameter of 0.59 mm, active diameter of 0.44 mm, and active length of 10 mm. A concept model I-RSBT needle/catheter pair was constructed using concentric 50 and 75 μm thick nickel-titanium alloy (nitinol) tubes. The needle is 16-gauge (1.651 mm) in outer diameter and the catheter contains a 535 μm thick platinum shield. I-RSBT and conventional HDR-BT treatment plans for a prostate cancer patient were generated based on Monte Carlo dose calculations. In order to minimize urethral dose, urethral dose gradient volumes within 0–5 mm of the urethra surface were allowed to receive doses less than the prescribed dose of 100%. Results: The platinum shield reduced the dose rate on the shielded side of the source at 1 cm off-axis to 6.4% of the dose rate on the unshielded side. For the case considered, for the same minimum dose to the hottest 98% of the clinical target volume (D 98% ), I-RSBT reduced urethral D 0.1cc below that of conventional HDR-BT by 29%, 33%, 38%, and 44% for urethral dose gradient volumes within 0, 1, 3, and 5 mm of the urethra surface, respectively. Percentages are expressed relative to the prescription dose of 100%. For the case considered, for the same urethral dose gradient volumes, rectum D 1cc was reduced by 7%, 6%, 6%, and 6%, respectively, and bladder D 1cc was reduced by 4%, 5%, 5%, and 6%, respectively. Treatment time to deliver 20 Gy with I-RSBT was 154 min with ten 62 GBq 153 Gd sources. Conclusions: For the case considered, the proposed 153 Gd-based I-RSBT system has the potential to lower the urethral dose relative to HDR-BT by 29%–44% if the clinician allows

  7. Auger Electron Therapy And Brachytherapy Tumor Treatment

    International Nuclear Information System (INIS)

    Laster, B.H.; Shani, G.

    2002-01-01

    Auger Electron Therapy (AET) is a binary approach for improving cancer radiotherapy. It involves the selective targeting of an atom to tumor cells using physiological pathway. The atom is then irradiated by a specific radiation that produces secondary radiation called Auger electrons. One of the problems associated with the clinical application of AET, is that the energy of the photons required for stimulating photoelectric absorption in most of the available high Z target atoms, is too low to achieve penetration through normal surrounding tissues to the depth of the tumor, when an external source is used. The solution is therefore the use of a brachytherapy technique. There are two other problems associated with the use of radiation as a cancer treatment. The first is the limitation on radiation dose to the normal tissue within the treatment volume. The second problem is the limitation imposed by the miniscule size of the critical target of the cell, namely the DNA (0.25% of the cell mass). The solution to the first problem can be achieved by using the brachytherapy technique. The second problem can be resolved by placing the radiation source in close position to the DNA. AET, as we apply it, provides the two solutions to the two problems. When a photon is absorbed by an electron in the K or L shell of an high Z atom, the electron is ejected from the atom, creating a vacancy in the shell. This vacancy is immediately filled with an electron from an upper shell. The energy difference between the two shells is sometimes emitted as an x-ray, however, frequently the energy is transferred to an outer shell electron that is emitted as an Auger electron. These electrons are emitted at energies of up to ∼30 keV and therefore have a very short range in the cell. They will deposit all their energy within 20-30 nm from the point of emission. i.e. all the energy is deposited in the DNA. In our work indium is used as the high Z atom

  8. The needs for brachytherapy source calibrations in the United States

    International Nuclear Information System (INIS)

    Coursey, B.M.; Goodman, L.J.; Hoppes, D.D.; Loevinger, R.; McLaughlin, W.L.; Soares, C.G.; Weaver, J.T.

    1992-01-01

    Brachytherapy sources of beta and gamma radiation ('brachy' is from the Greek, meaning 'near') have a long history of use in interstitial, intracavitary, intraluminal, and ocular radiation therapy. In the past the US national standards for these sources were often specified in activity or milligram radium equivalent. With the introduction of new radionuclide sources to replace radium, source strength calibrations are now expressed as air kerma rate at a meter. In this paper, we review the NIST standards for brachytherapy sources, list some of the common radionuclides and source encapsulations in use in the US radiology community, and describe the latest NIST work, in collaboration with several US medical institutions, on a method of two- and three-dimensional dose mapping of brachytherapy sources using radiochromic films. (orig.)

  9. Effects of brachytherapy on gene expressions of elastin and elastase

    International Nuclear Information System (INIS)

    Li Junming; Zhou Jingqun; Hu Bin; Li Shuguo

    2004-01-01

    Objective: To study the effects of brachytherapy on the gene expressions of elastin and elastase in cultured rat vascular smooth muscle cells (VSMCs). Methods: Rat VSMCs cultured in DMEM containing 10% FBS were irradiated by 60 Co γ-rays at 0, 7, 14, 28 Gy respectively. Then mRNA levels of elastin and elastase were determined by reverse transcription competitive PCR(RT-PCR). Results: Brachytherapy inhibited the expressions of elastase. Elastase mRNA decreased 25.3% and 50.1% in VSMC irradiated with 14, 28 Gy, respectively (P<0.05). The elastin mRNA level increased 80.7% and 102.3% in VSMC irradiated with 14, 25 Gy, respectively (P<0.05). Conclusion: Brachytherapy inhabits the expressions of elastase and increased elastin in VSMC cells

  10. Indication of brachytherapy of prostate with permanent implants

    International Nuclear Information System (INIS)

    Chauveinc, L.; Solignac, S.; Rosenwald, J.C.; Firmin, F.; Cosset, J.M.; Flam, T.; Thiounn, N.

    2002-01-01

    In the last decade, brachytherapy emerged as a particularly appealing new way of treating localized prostate cancer. Recently published 10-12 years biochemical control results appear to be superimposable to the best percentages achieved by surgery or conformal radiotherapy, with a small percentage of complications. This applied to severely patients. Only patients with T1/T2, PSA 60 g, hip mobility limitations, a urinary obstructive syndrome and previous trans-urethral resection lead to difficulties in technical implantation and therefore must be taken into account when discussing brachytherapy. In conclusion, for adequately selected patients, brachytherapy offers a particularly applied alternative to surgery and external radiotherapy, with satisfactory long term biochemical control rates and limited complications. (author)

  11. Algorithms for the process management of sealed source brachytherapy

    International Nuclear Information System (INIS)

    Engler, M.J.; Ulin, K.; Sternick, E.S.

    1996-01-01

    Incidents and misadministrations suggest that brachytherapy may benefit form clarification of the quality management program and other mandates of the US Nuclear Regulatory Commission. To that end, flowcharts of step by step subprocesses were developed and formatted with dedicated software. The overall process was similarly organized in a complex flowchart termed a general process map. Procedural and structural indicators associated with each flowchart and map were critiqued and pre-existing documentation was revised. open-quotes Step-regulation tablesclose quotes were created to refer steps and subprocesses to Nuclear Regulatory Commission rules and recommendations in their sequences of applicability. Brachytherapy algorithms were specified as programmable, recursive processes, including therapeutic dose determination and monitoring doses to the public. These algorithms are embodied in flowcharts and step-regulation tables. A general algorithm is suggested as a template form which other facilities may derive tools to facilitate process management of sealed source brachytherapy. 11 refs., 9 figs., 2 tabs

  12. Brachytherapy for elderly patients with stage II tongue cancer

    International Nuclear Information System (INIS)

    Kimura, Tomoki; Hirokawa, Yutaka; Fujita, Minoru; Murakami, Yuji; Kenjo, Masahiro; Kaneyasu, Yuko; Ito, Katsuhide

    2003-01-01

    In treatment choices of stage II (T2N0M0) tongue cancer, brachytherapy is less invasive and superior in function preservation, therefore its role is more important in elderly patients. The aim of this study was to evaluate treatment results and morbidity of brachytherapy for elderly patients with stage II tongue cancer. Between 1980 and 2001, 198 patients with stage II tongue cancer were treated with brachytherapy at Hiroshima University Hospital. Patient ages ranged from 21 to 89 years old (median: 62 years old). Patients were divided into three groups as follows: 119 patients younger than 65 years old (Non-Elderly group), 53 patients between 65 and 75 years old (Junior Elderly group), and 26 patients 75 years or older (Senior Elderly group). Radiotherapy was performed in 101 patients with brachytherapy alone, and in 97 patients with brachytherapy and external radiotherapy. Chemotherapy was also performed in 77 patients. Follow-up period ranged from 4 to 243 months (median: 55 months). The 5-year local control rate was 85% in the Non-Elderly group, 85% in the Junior Elderly group and 81% in the Senior Elderly group. There was no significant difference among these groups. The 5-year cause-specific survival rate was 85%, 81% and 70% respectively. The Senior Elderly group showed poorer cause-specific survival rate than the other two groups (p=0.03). There was also a tendency of higher incidence of neck metastasis and low salvage rate by neck dissection in the Senior Elderly group. Although the Senior Elderly group showed poorer cause-specific survival rate, the local control rate was similar to those of the other two groups. Brachytherapy is an effective treatment option for elderly patients with stage II tongue cancer. (author)

  13. A Cs-137 afterloading device. Preliminary results of cell kinetic effects of low dose-rate irradiation in an experimental tumour

    International Nuclear Information System (INIS)

    Rutgers, D.H.

    1988-01-01

    A Cs-137 afterloading technique is described which can be used in experimental tumours. Preliminary results, obtained with the human cervical carcinoma ME-180 xenografted to nude athymic mice, demonstrated that 20 Gy of low dose-rate irradiation induced an important redistribution of cells over cell cycle. The proportion of cells in G2-phase increased from 14.4% to 44.2% at 140 hours after irradiation. This method allows an accurate calculation of the dose-rate distribution in the tumour. Investigations of the cell kinetic effects of low dose-rate irradiation, at different dose-rates and different total doses, are therefore facilitated by the technique. (orig.) [de

  14. Brachytherapy in vulvar cancer: analysis of 18 patients

    International Nuclear Information System (INIS)

    Frezza, G.; Baldissera, A.; Bernardi, L.; Bunkheila, F.; Galuppi, A.; Salvi, F.

    1996-01-01

    INTRODUCTION: Vulvar cancer is a rather common neoplasm in elderly patients. Surgery, followed eventually by postoperative radiotherapy, is the treatment of choice. The results of exclusive radiotherapy (external beam irradiation and/or brachytherapy) are not well defined and in the recent literature only small series are reported. Radiotherapy however is the only therapeutic option in patients who are not fit for radical surgery. It is thus necessary to review its indications and its modalities. PATIENTS METHODS AND RESULTS: From 1990 to 1994 18 pts with a diagnosis of squamous cell carcinoma of the vulva have been submitted to brachytherapy. Age ranged from 60 to 92 years (mean age 76, 1 ys). 14 pts were treated at diagnosis (11 pts) or for recurrent disease after surgery (3 pts). In 8 of them brachytherapy (total dose 35-45 Gy, dose rate: 0,4-0,78 Gy/h) was preceded by external beam irradiation (Co60 or electron beam, 40-50 Gy to primary and inguinal nodes); 6 pts were treated with brachytherapy alone (58-60 Gy; dose rate 0,44-0,63 Gy/h). 4 pts underwent to brachytherapy alone for local recurrence after surgery and postoperative radiotherapy (total dose 45-60 Gy; dose rate 0,37-0,49 Gy/h). Brachytherapy was always performed with 192 Ir. Plastic tubes (2 to 5 lines) were used for single plane implantation of small exophytic lesions limited to the labia (8 cases); a perineal template (10 cases) was employed in lesions extended to the vaginal mucosa or involving the clitoris or the area of the perineum. (10(14)) pts treated at diagnosis are alive and free from local recurrence after 11-48 mos. 3 of them, treated with brachytherapy alone, have presented a nodal recurrence in the groin after 14, 15 and 27 mos. respectively. All of them are alive and free from disease after surgery and external radiotherapy. None of the pts treated for recurrent disease after surgery + external beam radiotherapy has achieved a local control. CONCLUSION: Brachytherapy alone or

  15. Volume correction factor in time dose relationships in brachytherapy

    International Nuclear Information System (INIS)

    Supe, S.J.; Sasane, J.B.

    1987-01-01

    Paterson's clinical data about the maximum tolerance doses for various volumes of interstitial implants with Ra-226 delivered in seven days was made use of in deriving volume correction factors for TDF and CRE concepts respectively for brachytherapy. The derived volume correction factors for TDF and for CRE differ fromthe one assumed for CRE by Kirk et al. and implied for TDF by Goitein. A normalising volume of 70 cc has been suggested for both CRE and TDF concepts for brachytherapy. A table showing the volume corrected TDF is presented for various volumes and dose rates for continuous irradiation. The use of this table is illustrated with examples. (orig.) [de

  16. Complications of esophageal stenting after radiotherapy and brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yorozu, Atsunori; Dokiya, Takushi; Ogita, Mikio; Kutuki, Shoji; Oki, Yosuke [National Second Hospital of Tokyo (Japan)

    1997-11-01

    The purpose of our study was to evaluate safety and complications of stenting after radiotherapy and brachytherapy. Fifteen of 21 patients showed improvement of dysphagia by stenting. But 6 of 21 patients had perforation or massive bleeding relating to stents. The risk for perforation or hemorrhage appears to be even higher in patients who have previously undergone radical radiotherapy and brachytherapy within one month before stenting. Stenting at 6 months or more after radical radiotherapy seems to be an effective and safe method of long-lasting palliation for severe dysphagia with recurrent esophageal cancer. (author)

  17. Australian high-dose-rate brachytherapy protocols for gynaecological malignancy

    International Nuclear Information System (INIS)

    MacLeod, C.; Dally, M.; Stevens, M.; Thornton, D.; Carruthers, S.; Jeal, P.

    2001-01-01

    There is no consensus over the optimal dose fractionation schedules for high-dose-rate (HDR) brachytherapy used for gynaecological malignancy. In Australian public hospital departments of radiation oncology, HDR brachytherapy for gynaecological cancer is being more commonly used. A survey of public departments that are using this technology, or that plan to introduce this technology, was performed. Their current protocols are presented. In general, protocols are similar biologically; however, the practical aspects such as the number of fractions given do vary and may reflect resource restrictions or, alternatively, differences in interpretations of the literature and of the best protocols by clinicians. Copyright (2001) Blackwell Science Pty Ltd

  18. SU-E-T-375: Evaluation of a MapCHECK2(tm) Planar 2-D Diode Array for High-Dose-Rate Brachytherapy Treatment Delivery Verifications

    Energy Technology Data Exchange (ETDEWEB)

    Macey, N; Siebert, M; Shvydka, D; Parsai, E [University of Toledo Medical Center, Toledo, OH (United States)

    2015-06-15

    Purpose: Despite improvements of HDR brachytherapy delivery systems, verification of source position is still typically based on the length of the wire reeled out relative to the parked position. Yet, the majority of errors leading to medical events in HDR treatments continue to be classified as missed targets or wrong treatment sites. We investigate the feasibility of using dose maps acquired with a two-dimensional diode array to independently verify the source locations, dwell times, and dose during an HDR treatment. Methods: Custom correction factors were integrated into frame-by-frame raw counts recorded for a Varian VariSource™ HDR afterloader Ir-192 source located at various distances in air and in solid water from a MapCHECK2™ diode array. The resultant corrected counts were analyzed to determine the dwell position locations and doses delivered. The local maxima of polynomial equations fitted to the extracted dwell dose profiles provided the X and Y coordinates while the distance to the source was determined from evaluation of the full width at half maximum (FWHM). To verify the approach, the experiment was repeated as the source was moved through dwell positions at various distances along an inclined plane, mimicking a vaginal cylinder treatment. Results: Dose map analysis was utilized to provide the coordinates of the source and dose delivered over each dwell position. The accuracy in determining source dwell positions was found to be +/−1.0 mm of the preset values, and doses within +/−3% of those calculated by the BrachyVision™ treatment planning system for all measured distances. Conclusion: Frame-by-frame data furnished by a 2 -D diode array can be used to verify the dwell positions and doses delivered by the HDR source over the course of treatment. Our studies have verified that measurements provided by the MapCHECK2™ can be used as a routine QA tool for HDR treatment delivery verification.

  19. Radiographic Control of 137-Cs Brachytherapy Sources

    International Nuclear Information System (INIS)

    Bistrovic, M.; Viculin, T.; Jurkovic, S.

    2003-01-01

    1 37C s brachytherapy sources are practical for the intracavitary application due to their relatively long lifetime (T 1/2 = 30 y). On the other hand, due to the relatively low energy (0.66 MeV) of the emitted photons, they are suitable for an efficient radiation protection. The dose distribution around the sources is usually calculated by a specific program. However this program requires the knowledge of the position of sources within the applicator as well as the distribution of activity along them. The only way to learn these data is to make an X-ray picture of applicators and sources superimposed to the autoradiography of every source. It is difficult to achieve satisfactory radiographs with high dose rate sources with standard X-ray film material because autoradiography covers the structure of the radiographic shadow. The problem can be overcome either by applying a high intensity X-ray or gamma beam (originating from a radiotherapeutic machine), or by using photographic material of very low sensitivity, for example photographic paper. Combining both possibilities one can obtain satisfactory images. (author)

  20. Endovascular brachytherapy to prevent restenosis after angioplasty

    International Nuclear Information System (INIS)

    Wohlgemuth, W.A.; Bohndorf, K.

    2003-01-01

    Endovascular radiotherapy is the first effective prophylaxis of restenosis after percutaneous transluminal angioplasty (PTA) and stenting. The FDA recently approved two devices for the delivery of intracoronary radiation following coronary artery stenting. Published multicenter, double-blind, randomized trials of intracoronary radiation therapy report good results for preventing in-stent restenosis, while the data for the peripheral circulation are still inconclusive. Beta-emitters are easier applicable and probably also safer, whereas gamma-emitters have been more extensively evaluated clinically so far. Primary indication for endovascular brachytherapy are patients at high risk for restenosis, such as previous restenoses, in-stent hyperplasia, long stented segment, long PTA lesion, narrow residual vascular lumen and diabetes. Data from coronary circulation suggest a safety margin of at least 4 to 10 mm at both ends of the angioplastic segment to avoid edge restenosis. To prevent late thrombosis of the treated coronary segment, antiplatelet therapy with clopidogrel and aspirin are recommended for at least 6 months after PTA and for 12 months after a newly implanted stent. An established medication regimen after radiotherapy of peripheral arteries is still lacking. (orig.) [de

  1. A quality management program in intravascular brachytherapy

    International Nuclear Information System (INIS)

    Chakri, Abderrahim; Thomadsen, Bruce

    2002-01-01

    While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to deliver the correct dose, to the correct location, safety. To develop an effective and comprehensive quality management (QM) program for IVB, a physicist should utilize proven risk assessment techniques rather than simply thinking of things to check, and follow guidances such as ISO9001:2000. The proposed QM program includes the following: Procedures designed to assure the safety of the patient: Identification of the patient; tests of the integrity and patency for the delivery catheter, operation of the source train, and patency of the catheter in the treatment position; a check for recovery preparations; and verification of source recovery. Procedures to assure positional accuracy of the treatment: Verification of the positioning the catheter in the artery and of the sources in the catheter. Procedures to assure dosimetry accuracy: Acceptance testing of the device, including verification of the source strength and uniformity, and of the treatment duration tables; verification of the treatment prescription and duration for each patient; and control measures that minimize the likelihood of errors removing the source at the correct time

  2. Radiation safety parameters following prostate brachytherapy

    International Nuclear Information System (INIS)

    Smathers, Sesalie; Wallner, Kent; Korssjoen, Tammy; Bergsagel, Carl; Hudson, Rick H.; Sutlief, Steven; Blasko, John

    1999-01-01

    Purpose: To determine the degree and variability of radiation exposure to the general public from patients after I-125 or Pd-103 prostate brachytherapy. Methods and Materials: Radiation exposure measurements were made from 38 consecutive, unselected patients with stage T1 or T2 prostatic carcinoma who had trans perineal I-125 or Pd-103 implants at the University of Washington in 1998. Results: The exposure rate at the anterior skin surface following a I-125 implant ranged from 2.2 to 8.9 mrem/hour (average: 5.0). The exposure rate at the anterior skin surface from a Pd-103 implant ranged from 0.5 to 4.9 mrem/hour (average: 1.7). Based on the current Nuclear Regulatory Commission (NRC) regulations the time required to reach the annual limit at the anterior skin surface would be 20 hours for I-125 and 59 hours for Pd-103. For exposure at the lateral skin surface, the times would exceed 500 hours for either isotope. Conclusions: This data suggest that patients need not be concerned about being a radiation risk to the general public following their procedure

  3. Radiation Protection Training in Intracoronary Brachytherapy

    International Nuclear Information System (INIS)

    Prieto, C.; Vano, E.; Fernandez, J. M.; Sabate, M.; Galvan, C.; Meiggs, L.; Corral, J. M.

    2003-01-01

    To report the educational objectives and contents on Radiation Protection (RP) for the practice of Intracoronary Brachytherapy (ICB) procedures. The wide international experience on training programs for ICB as well as our own experience organizing several courses aimed at Cardiologists, Radio therapists and Medical Physicists has been used to elaborate specific RP objectives and contents. The objectives, differentiated for Cardiologists, Radio therapists, Medical Physicists, Nurses and Technicians, pretend to guarantee the safety and RP of both patient and staff in the procedures of ICB. The objectives are necessarily different because their RP formation and their role in the procedure are different. The general topics included in RP training programmes for ICB could be: general topics on RP (Interaction of radiation and matter, RP principles, radiobiology, etc), principles of operation of ICB and interventional X-ray equipment, quantification of radiation dose and risks, optimisation of protection of staff and patients, accidents and emergencies, regulations, responsibilities, quality assurance program, handling of ICB sources, installation and commissioning. Training programs based on the objectives presented in this paper would encourage positive safety culture in ICB and can also be used as a starting point by the Regulatory Authority for the authorization of new Installations and credentialing of professionals involved in this technique as well as for the continuous education of the staff involved. (Author) 10 refs

  4. Dose assessment for brachytherapy with Henschke applicator

    International Nuclear Information System (INIS)

    Yu, Pei-Chieh; Chao, Tsi-Chian; Tung, Chuan-Jong; Wu, Ching-Jung; Lee, Chung-Chi

    2011-01-01

    Dose perturbation caused by the Henschke applicator is a major concern for the brachytherapy planning system (BPS) in recent years. To investigate dose impact owing to neglect of the metal shielding effect, Monte Carlo (MC) simulation, BPS calculation, and film measurement have been performed for dose assessment in a water phantom. Additionally, a cylindrical air cavity representing the rectum was added into the MC simulation to study its effect on dose distribution. Monte Carlo N-Particle Transport Code (MCNP) was used in this study to simulate the dose distribution using a mesh tally. This Monte Carlo simulation has been validated using the TG-43 data in a previous report. For the measurement, the Henschke applicator was placed in a specially-designed phantom, and Gafchromic films were inserted in the center plane for 2D dose assessment. Isodose distributions with and without the Henschke applicator by the MC simulation show significant deviation from those by the BPS. For MC simulation, the isodose curves shrank more significantly when the metal applicator was applied. For the impact of the added air cavity, the results indicate that it is hard to distinguish between with and without the cavity. Thus, the rectum cavity has little impact on the dose distribution around the Henschke applicator.

  5. Dose optimisation in single plane interstitial brachytherapy

    DEFF Research Database (Denmark)

    Tanderup, Kari; Hellebust, Taran Paulsen; Honoré, Henriette Benedicte

    2006-01-01

    patients,       treated for recurrent rectal and cervical cancer, flexible catheters were       sutured intra-operatively to the tumour bed in areas with compromised       surgical margin. Both non-optimised, geometrically and graphically       optimised CT -based dose plans were made. The overdose index...... on the       regularity of the implant, such that the benefit of optimisation was       larger for irregular implants. OI and HI correlated strongly with target       volume limiting the usability of these parameters for comparison of dose       plans between patients. CONCLUSIONS: Dwell time optimisation significantly......BACKGROUND AND PURPOSE: Brachytherapy dose distributions can be optimised       by modulation of source dwell times. In this study dose optimisation in       single planar interstitial implants was evaluated in order to quantify the       potential benefit in patients. MATERIAL AND METHODS: In 14...

  6. Halo's production in vitro on brachytherapy experiments

    International Nuclear Information System (INIS)

    Cuperschmid, Ethel M.; Sarmento, Eduardo V.; Campos, Tarcisio P.R.

    2011-01-01

    Since earlier of 1960, one of the most significant contributions of radiation biology has been the theory of cell killing as a function of increasing doses of a cytotoxic agent, as well as the demonstration of repair of sublethal or potentially lethal damage after irradiation. The impact of cellular and molecular radiobiology, by exploitation of cellular mechanisms related to apoptosis, may be the cell killing with irradiation by including changes other than unrepaired DNA damage. Based on the understanding of the tumor microenvironment and how growth factors and proteins produced by irradiated cells may alter cellular processes, improved combined-modality strategies may emerge. This effect was show since 1960's, but here we propose to demonstrate this phenomenon in Brachytherapy. The present goal is to verify the macroscopic response through the production and analysis of clonogenic control based on halos generation by radioactive seeds of Ho-165 and Sm-153, aiming to study the effect of this type of irradiation. Confluent cell culture flasks with HeLa cell line were subjected to radiation in a period up to five half-lives of radionuclide, respectively. Devices were introduced which set the polymer-ceramic Ho-165 and Sm-153 seeds in the vials. After a period of exposure, the flasks were stained with violet Gensiana. The results showed the formation of halos control of confluent cancer cells. This paper will describe these experiments in the current stage of the research and report the implications of this new way of therapy for cancer treatment. (author)

  7. High dose rate brachytherapy using custom made superficial mould applicators and Leipzig applicators for non melanoma localized skin cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, A. Cassio A.; Miziara, Daniela; Lima, Flavia Pedroso de; Miziara, Miguel

    2014-07-01

    Purpose: advances in technology and the commercial production of Leipzig applicators allowed High Dose Rate after-load brachytherapy (HDR-BT) to address a number of the challenges associated with the delivery of superficial radiation to treat localized non melanoma skin cancer (NMSK). We reviewed our uni-institutional experience on the treatment of NMSK with HDR-BT. Methods: data were collected retrospectively from patients attending the Radiation Oncology Department at AV Carvalho Insitute, Sao Paulo, Brazil. HDR-BT was done using the stepping source HDR 192Ir Microselectron (Nucletron BV). The planning target volume consisted of the macroscopic lesion plus a 5mm to 10mm margin.The depth of treatment was 0.5 cm in smaller (< 2.0 cm) tumors and 10 to 15 mm for lesions bigger than that. Results: Thirteen patients were treated with HDR-BT from June, 2007 to June 2013. The median age and follow up time were 72 (38-90) years old and 36 (range, 7-73) months, respectively. There a predominance of males (61.5%) and of patients referred for adjuvant treatment due positive surgical margins or because they have had only a excision biopsy without safety margins (61.5%). Six (46.2%) patients presented with squamous cell carcinoma and 7 (53.8%) patients presented with basal cell carcinoma. The median tumor size was 20 (range, 5-42) mm. Patients were treated with a median total dose of 40 Gy (range, 20 -60), given in 10 (range, 2-15) fractions, given daily or twice a week. All patients responded very well to treatment and only one patient has failed locally so far, after 38 months of the end of the irradiation. The crude and actuarial 3-year local control rates were 100% and 80%, respectively. Moist desquamation, grade 2 RTOG, was observed in 4 (30.8%) patients. Severe late complication, radiation-induced dyspigmentation, occurred in 2 patients and 1 of the patients also showed telangiectasia in the irradiated area. The cosmetic result was considered good in 84% (11/13) patients

  8. High dose rate brachytherapy using custom made superficial mould applicators and Leipzig applicators for non melanoma localized skin cancer

    International Nuclear Information System (INIS)

    Pellizzon, A. Cassio A.; Miziara, Daniela; Lima, Flavia Pedroso de; Miziara, Miguel

    2014-01-01

    Purpose: advances in technology and the commercial production of Leipzig applicators allowed High Dose Rate after-load brachytherapy (HDR-BT) to address a number of the challenges associated with the delivery of superficial radiation to treat localized non melanoma skin cancer (NMSK). We reviewed our uni-institutional experience on the treatment of NMSK with HDR-BT. Methods: data were collected retrospectively from patients attending the Radiation Oncology Department at AV Carvalho Insitute, Sao Paulo, Brazil. HDR-BT was done using the stepping source HDR 192Ir Microselectron (Nucletron BV). The planning target volume consisted of the macroscopic lesion plus a 5mm to 10mm margin.The depth of treatment was 0.5 cm in smaller (< 2.0 cm) tumors and 10 to 15 mm for lesions bigger than that. Results: Thirteen patients were treated with HDR-BT from June, 2007 to June 2013. The median age and follow up time were 72 (38-90) years old and 36 (range, 7-73) months, respectively. There a predominance of males (61.5%) and of patients referred for adjuvant treatment due positive surgical margins or because they have had only a excision biopsy without safety margins (61.5%). Six (46.2%) patients presented with squamous cell carcinoma and 7 (53.8%) patients presented with basal cell carcinoma. The median tumor size was 20 (range, 5-42) mm. Patients were treated with a median total dose of 40 Gy (range, 20 -60), given in 10 (range, 2-15) fractions, given daily or twice a week. All patients responded very well to treatment and only one patient has failed locally so far, after 38 months of the end of the irradiation. The crude and actuarial 3-year local control rates were 100% and 80%, respectively. Moist desquamation, grade 2 RTOG, was observed in 4 (30.8%) patients. Severe late complication, radiation-induced dyspigmentation, occurred in 2 patients and 1 of the patients also showed telangiectasia in the irradiated area. The cosmetic result was considered good in 84% (11/13) patients

  9. Underuse of brachytherapy for the treatment of dysphagia owing to esophageal cancer. An Italian survey.

    Science.gov (United States)

    Fuccio, Lorenzo; Guido, Alessandra; Hassan, Cesare; Frazzoni, Leonardo; Arcelli, Alessandra; Farioli, Andrea; Giaccherini, Lucia; Galuppi, Andrea; Mandolesi, Daniele; Cellini, Francesco; Mantello, Giovanna; Macchia, Gabriella; de Bortoli, Nicola; Repici, Alessandro; Valentini, Vincenzo; Bazzoli, Franco; Morganti, Alessio Giuseppe

    2016-10-01

    International guidelines strongly recommend brachytherapy as valid alternative or in addition to stenting in patients with dysphagia owing to esophageal cancer. However, for not well understood reasons, brachytherapy is definitively underused for the palliative treatment of malignant dysphagia. Aim of the current survey was to investigate the use of brachytherapy for the treatment of malignant dysphagia in Italy. A structured questionnaire was submitted to the 1510 members of the Italian Association of Radiation Oncologists (AIRO). These members refer to 177 centres of radiotherapy across Italy and in 68 (38.4%) of them brachytherapy is routinely performed. Of the 1510 invited members, 178 completed the survey (11.7%). The answers provided by the 178 participants allowed to get information on 40 out of 68 brachytherapy centres (58.8%). Seven out of 40 (17.5%) centres perform brachytherapy of the oesophagus, in 3 out of 40 (7.5%) centres brachytherapy represents the first line of treatment. The main reason why brachytherapy is not routinely performed is the lack of experience. Despite the strong recommendations of the international guidelines and the wide diffusion of brachytherapy centres across Italy, only very few of them routinely considered brachytherapy for the treatment of dysphagia due to esophageal cancer. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  10. Current status of brachytherapy in Korea: a national survey of radiation oncologists.

    Science.gov (United States)

    Kim, Haeyoung; Kim, Joo Young; Kim, Juree; Park, Won; Kim, Young Seok; Kim, Hak Jae; Kim, Yong Bae

    2016-07-01

    The aim of the present study was to acquire information on brachytherapy resources in Korea through a national survey of radiation oncologists. Between October 2014 and January 2015, a questionnaire on the current status of brachytherapy was distributed to all 86 radiation oncology departments in Korea. The questionnaire was divided into sections querying general information on human resources, brachytherapy equipment, and suggestions for future directions of brachytherapy policy in Korea. The response rate of the survey was 88.3%. The average number of radiation oncologists per center was 2.3. At the time of survey, 28 centers (36.8%) provided brachytherapy to patients. Among the 28 brachytherapy centers, 15 (53.5%) were located in in the capital Seoul and its surrounding metropolitan areas. All brachytherapy centers had a high-dose rate system using (192)Ir (26 centers) or (60)Co (two centers). Among the 26 centers using (192)Ir sources, 11 treated fewer than 40 patients per year. In the two centers using (60)Co sources, the number of patients per year was 16 and 120, respectively. The most frequently cited difficulties in performing brachytherapy were cost related. A total of 21 centers had a plan to sustain the current brachytherapy system, and four centers noted plans to upgrade their brachytherapy system. Two centers stated that they were considering discontinuation of brachytherapy due to cost burdens of radioisotope source replacement. The present study illustrated the current status of brachytherapy in Korea. Financial difficulties were the major barriers to the practice of brachytherapy.

  11. Vaginal HDR-afterloading in the treatment of endometrial carcinoma - analysis of side effects and relapse rates

    International Nuclear Information System (INIS)

    Weiss, E.; Arnold-Bofinger, H.; Weidner, N.; Hirnle, P.; Bamberg, M.

    1996-01-01

    Introduction: In a retrospective analysis side effects, relapse rates and the value of in vivo dosimetry for vaginal HDR-brachytherapy (BT) in women with endometrial carcinoma are evaluated. Material and Methods: From 1987 to 1993 124 women received vaginal HDR-BT (Ir-192) only for adjuvant treatment of early endometrial carcinoma. The usual fractionation was 1x7 Gy per week applied to the surface of the vaginal cylinder to a total dose of 21 Gy. During BT we performed in vivo dosimetry using bladder and rectal probes. The measured doses per patient in the bladder ranged from 1.5 to 9.8 Gy, 6.7 Gy in the mean. In the rectum the mean dose was 8.2 Gy (1.7 to 13.8 Gy). Results: The analysis of side effects shows that only 23 of 124 women (18 %) reported any problems at all. 13 women (10 %) noticed dysuria or pollakisuria for a maximum of 6 weeks. The average measured bladder dose in those patients was 5.3 Gy, (below the average bladder dose of 6.7 Gy). Diarrhea was reported in 3 patients (2 %), in those the average measured rectal dose was 6.8 Gy (lower than the average rectal dose of 8.2 Gy). 6 women (5 %) received antibiotic treatment because of bacteriuria. Of all patients 10 (8%) had a pelvic relapse, 3 in the vagina only. 5 women showed distant metastases during follow-up (3 of those having also a local relapse). Discussion and Conclusion: With only 2 % vaginal relapses HDR-BT is a save method to reduce the probability of vaginal metastases of endometrial carcinoma in an adjuvant setting. Moreover the incidence of acute side effects is low, no lasting complications were seen in our patients. There existed no correlation between the incidence of side effects and the measured in vivo doses in bladder and rectum, questioning the future usage in the era of well advanced BT-planning systems

  12. Electromagnetic tracking for treatment verification in interstitial brachytherapy

    DEFF Research Database (Denmark)

    Bert, Christoph; Kellermeier, Markus; Tanderup, Kari

    2016-01-01

    Electromagnetic tracking (EMT) is used in several medical fields to determine the position and orientation of dedicated sensors, e.g., attached to surgical tools. Recently, EMT has been introduced to brachytherapy for implant reconstruction and error detection. The manuscript briefly summarizes...

  13. Brachytherapy in Europe: philosophies, current practice and future directions

    International Nuclear Information System (INIS)

    Haworth, A.

    2000-01-01

    Full text: Five months sabbatical leave provided an opportunity to visit six radiotherapy centres in France, Holland and England. While brachytherapy philosophies and practices within each country were similar, there were considerable differences in attitudes between countries. The Institute Gustave Roussy, home of the Paris System and host for the French sector confirmed that the Paris System is still very much the preferred dosimetry method in this part of the world. Though their preference for low dose rate brachytherapy is still evident, high dose rate brachytherapy has found some applications but the rules of the Paris System are never far away and the words 'what about the hyperdose sleeve' are firmly implanted into this visitor's brain. The use of real time dosimetry for I-125 prostate brachytherapy at the Institute Curie (Paris) provided an interesting contrast to the standard pre and post implant dosimetry techniques commonly employed elsewhere. The two Dutch centres on the itinerary, in stark contrast to the traditional techniques seen in France, have applied the power of computers to investigate optimisation of the classic dosimetry systems and called on the analysis techniques (DVH, NTCP, TCP etc) now familiar to us all in external beam therapy. The Cookridge Hospital in England fitted somewhere between the French and Dutch centres. This centre showed how both modern and traditional techniques could be applied in an efficient way for a large variety of treatment sites. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  14. In vivo dosimetry: trends and prospects for brachytherapy

    DEFF Research Database (Denmark)

    Kertzscher, Gustavo; Rosenfeld, A.; Beddar, S.

    2014-01-01

    The error types during brachytherapy (BT) treatments and their occurrence rates are not well known. The limited knowledge is partly attributed to the lack of independent verification systems of the treatment progression in the clinical workflow routine. Within the field of in vivo dosimetry (IVD)...

  15. Source of hope [El Salvador’s only brachytherapy centre

    International Nuclear Information System (INIS)

    Falcon Castro, Nancy

    2010-01-01

    Set up in 2008 with the IAEA’s support, the Cancer Institute 'Dr. Narciso Diaz Bazan' is El Salvador’s only brachytherapy treatment facility for women affected by uterine cancer. To date, over 1000 women affected by cervical cancer have received treatment in the centre

  16. Urethral toxicity after LDR brachytherapy: experience in Japan.

    Science.gov (United States)

    Tanaka, Nobumichi; Asakawa, Isao; Hasegawa, Masatoshi; Fujimoto, Kiyohide

    2015-01-01

    Urinary toxicity is common after low-dose-rate (LDR) brachytherapy, and the resolution of urinary toxicity is a concern. In particular, urinary frequency is the most common adverse event among the urinary toxicities. We have previously reported that approximately 70% of patients experience urinary frequency during the first 6 months after seed implantation. Most urinary adverse events were classified as Grade 1, and Grade 2 or higher adverse events were rare. The incidence of urinary retention was approximately 2-4%. A high International Prostate Symptom Score before seed implantation was an independent predictor of acute urinary toxicity of Grade 2 or higher. Several previous reports from the United States also supported this trend. In Japan, LDR brachytherapy was legally approved in 2003. A nationwide prospective cohort study entitled Japanese Prostate Cancer Outcome Study of Permanent Iodine-125 Seed Implantation was initiated in July 2005. It is an important issue to limit urinary toxicities in patients who undergo LDR brachytherapy. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  17. Endobronchial brachytherapy: the Saint-Louis Hospital experience

    International Nuclear Information System (INIS)

    Hennequin, C.; Durdux, C.; Housset, M.; Maylin, C.; Tredaniel, J.; Zalcman, G.; Hirsch, A.; Dray, M.; Manoux, D.; Perret, M.

    1997-01-01

    During the evolution of lung cancer, bronchial obstruction is often noticed and is sometimes responsible for serious symptoms. Several methods of des-obstruction can be proposed, including brachytherapy. Materials and methods: One hundred forty-nine patients, presenting with endobronchial brachytherapy were included into the study. Seventy-three were treated with curative intent, 47 with palliative intent and 29 with a combination of external irradiation and brachytherapy. We usually delivered a series of two 7-Gy fractions (1 cm from the catheter), the treatment being repeated one, two or three times. Results: When all symptoms were taken into account, respiratory function improvement was present in 79% of the patients. Among the 132 tumors that could be evaluated via a new endoscopy 2 months after treatment, 64 (48.5%) were in complete histological remission. The median survival was 14.4 months for the patients treated with curative intent. Eleven massive hemoptyses and 13 radiation bronchitides were observed. Conclusion: These results confirm the feasibility and good results related to endobronchial brachytherapy, though controlled studies are needed to better define its place in the therapeutic strategy of bronchial carcinomas. (authors)

  18. Brachytherapy in cervix cancers: techniques and concepts evolution

    International Nuclear Information System (INIS)

    Haie-Meder, C.; Crevoisier, R. de; Petrow, P.; Fromm, S.; Delapierre, M.; Albano, M.; Petit, C.; Briot, E.

    2003-01-01

    Brachytherapy plays an important role in the treatment of patients with cervical carcinoma. Technical modalities have evolved during the last years and have benefited from imaging modalities development, specially MRI. Imaging modalities contribute to a better knowledge of tumoral extension and critical organs. Ultrasound during brachytherapy has led to the almost complete eradication of uterine perforation. In the future, a more systematic use of systems allowing optimization may induce a better dose distribution in the tumor as well as in the critical organs. Recent data provided information in favor of a better analysis in the relative role of dose-rate, total dose and treated volume and their influence on the local control and complication incidence. Concomitant radio-chemotherapy represents a standard in the treatment of patients with tumoral size exceeding 4 cm. Some questions still remain: is concomitant chemotherapy of benefit during brachytherapy? Is there any place for complementary surgery, specially in patients with complete response after external irradiation with concomitant chemotherapy and brachytherapy? In order to answer the former question, a phase III randomized trial is going to start, with the Federation Nationale des Centres de Lutte Contre le Cancer as a promoter. (authors)

  19. Radiation exposure of nursing personnel to brachytherapy patients

    International Nuclear Information System (INIS)

    Cobb, P.D.; Kase, K.R.; Bjaerngard, B.E.

    1978-01-01

    The radiation exposure of nursing personnel to brachytherapy patients has been analyzed from data collected during the years 1973-1976, at four different hospitals. The average annual dose per exposed nurse ranged between 25 and 150 mrem. The radiation exposure per nurse was found to be proportional to the total potential exposure and was uncorrelated with the size of the nursing staff. (author)

  20. Dose determination in breast tumor in brachytherapy using Iridium-192

    International Nuclear Information System (INIS)

    Okuno, S.F.

    1984-01-01

    Thermoluminescent dosimetry studies in vivo and in vitro aiming to determing radiation dose in the breast tumor, in brachytherapy using Iridium-192 was done. The correlation between radiation doses in tumor and external surface of the breast was investigated for correcting the time interval of radiation source implantation. (author) [pt

  1. Radiation exposure after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Cattani, Federica; Vavassori, Andrea; Polo, Alfredo; Rondi, Elena; Cambria, Raffaella; Orecchia, Roberto; Tosi, Giampiero

    2006-01-01

    Background and purpose: Limited information is available on the true radiation exposure and associated risks for the relatives of the patients submitted to prostate brachytherapy with permanent implant of radioactive sources and for any other people coming into contact with them. In order to provide appropriate information, we analyzed the radiation exposure data from 216 prostate cancer patients who underwent 125 I or 103 Pd implants at the European Institute of Oncology of Milan, Italy. Patients and methods: Between October 1999 and October 2004, 216 patients with low risk prostate carcinoma were treated with 125 I (200 patients) or 103 Pd (16 patients) permanent seed implantation. One day after the procedure, radiation exposure measurements around the patients were performed using an ionization chamber survey meter (Victoreen RPO-50) calibrated in dose rate at an accredited calibration center (calibration Centre SIT 104). Results: The mean dose rate at the posterior skin surface (gluteal region) following 125 I implants was 41.3 μSv/h (range: 6.2-99.4 μSv/h) and following 103 Pd implants was 18.9 μSv/h (range 5.0-37.3 μSv/h). The dose rate at 50 cm from the skin decreased to the mean value of 6.4 μSv/h for the 125 I implants and to the mean value of 1.7 μSv/h for the 103 Pd implants. Total times required to reach the annual dose limit (1 mSv/year) recommended for the general population by the European Directive 96/29/Euratom and by the Italian law (Decreto Legislativo 241/2000) at a distance of 50 cm from the posterior skin surface of the implanted patient would be 7.7 and 21.6 days for 125 I and for 103 Pd. Good correlation between the measured dose rates and both the total implanted activity and the distance between the most posteriorly implanted seed and the skin surface of the patients was found. Conclusions: Our data show that the dose rates at 50 cm away from the prostate brachytherapy patients are very low and that the doses possibly absorbed by the

  2. Isotope selection for patients undergoing prostate brachytherapy

    International Nuclear Information System (INIS)

    Cha, Christine M.; Potters, Louis; Ashley, Richard; Freeman, Katherine; Wang Xiaohong; Waldbaum, Robert; Leibel, Steven

    1999-01-01

    Purpose: Ultrasound-guided trans perineal interstitial permanent prostate brachytherapy (TIPPB) is generally performed with either 103 Pd or 125 I. The use of 125 I for low Gleason score tumors and 103 Pd for higher Gleason scores has been suggested based on isotope dose rate and cell doubling time observed in in vitro studies. While many centers follow these isotope selection criteria, other centers have elected to use only a single isotope, regardless of Gleason score. No clinical data have been published comparing these isotopes. This study was undertaken to compare outcomes between 125 I and 103 Pd in a matched pair analysis for patients undergoing prostate brachytherapy. Methods and Materials: Six hundred forty-eight consecutively treated patients with clinically confined prostate cancer underwent TIPPB between June 1992 and February 1997. Five hundred thirty-two patients underwent TIPPB alone, whereas 116 received pelvic external beam irradiation and TIPPB. Ninety-three patients received androgen deprivation therapy prior to TIPPB. The prescribed doses for TIPPB were 160 Gy for 125 I (pre-TG43) and 120 Gy for 103 Pd. Patients treated with combination therapy received 41.4 or 45 Gy (1.8 Gy/fraction) external beam irradiation followed by a 3- to 5-week break and then received either a 120-Gy 125 I or a 90-Gy 103 Pd implant. Until November 1994, all patients underwent an 125 I implant after which the isotope selection was based on either Gleason score (Gleason score 2-5: 125 I; Gleason 5-8: 103 Pd) or isotope availability. A matched pair analysis was performed to assess any difference between isotopes. Two hundred twenty-two patients were matched according to Gleason score, prostate-specific antigen (PSA), and stage. PSA relapse-free survival (PSA-RFS) was calculated based on the American Society for Therapeutic Radiology and Oncology (ASTRO) Consensus Group definition of failure. Kaplan-Meier actuarial survival curves were compared to assess differences in

  3. Medical physics aspects of ophthalmic brachytherapy

    International Nuclear Information System (INIS)

    Sharma, S.D.; Shanta, A.; Palani Selvam, T.; Tripathi, U.B.; Bhatt, B.C.

    2004-11-01

    Intraocular melanoma is the most common primary malignancy of the eye. Radiation therapy using ophthalmic plaque has proved successful in the management of various ocular lesions. Although a few centres were using 90 Sr/ 90 Y plaques for shallow turtlours some years ago, eye plaque therapy was not a common practice in India. A revived interest in the use of eye plaque therapy and very high cost of imported sources has led to the development and production of 125 I seed sources by the Radiopharmaceuticals Division, BARC. This report presents a brief description on the clinical, dosimetry and radiation safety aspects of 90 Sr/ 90 Y and 106 Ru/ 106 Rh beta ray and 125 I gamma ray eye plaque applicators. This report has been divided in five Sections. Section I presents general introduction of ophthalmic brachytherapy including the structure of a human eye, types of ophthalmic plaques and characteristics of radioisotopes commonly used in such applications. A brief review of sources, applicators and dosimetry of 90 Sr/ 90 Y and 106 Ru/ 106 Rh beta and 125 I gamma ophthalmic plaques are given in Section II and Section III, respectively. Section IV contains the single seed dosimetry data of BARC OcuProsta 125 I seed as well as dosimetry data of typical eye plaques loaded with BARC OcuProsta 125 I seed. Quality assurance and radiation safety aspects of these eye applicators are described in Section V. A proforma of the application required to be filled in by the user institution for obtaining regulatory consent to start eye plaque therapy has also been appended to this report. (author)

  4. A therapeutic gain model for brachytherapy

    International Nuclear Information System (INIS)

    Wigg, D.R.

    2003-01-01

    When treating with continuous irradiation the potential therapeutic gain or loss depends on several treatment, normal tissue and tumour variables. There are similarities between equations defining tissue effects with fractionated treatment and brachytherapy. The former is sensitive to dose per fraction (and incomplete repair for short intervals between treatments) and the later is sensitive to dose rate and continuous repair factors. Because of these similarities, for typical tumours and normal tissues, dose per fraction and dose rates generally work in similar directions. As the dose per fraction or dose rate increases the therapeutic gain falls. With continuous irradiation the dose rates effects are determined by Beta cell kill and hence the absolute value of Beta . Minimal sensitivity occurs at very low and very high dose rates. The magnitude of cell kill also depends on the Continuous Repair Factor (g) which is a function of the treatment time and the Repair Half Time (in hours) of the tissues (Repair Half Time T 1/2Ln(2)/h, when h the Repair Constant). An interactive optimising model has been written to predict the therapeutic gain or loss as the parameter values are varied. This model includes the tumour and normal tissue parameters alpha and beta Gy (or individual values), their Repair Half Times, dose rates and overall treatment time. The model is based on the Linear-Quadratic equation and the Total Effect (TE) method of Thames and Hendry although the Extrapolated Response Dose (ERD) method of Barendsen produces the same results. The model is written so that the gain or loss may be seen when treatment is always to normal tissue tolerance doses. The magnitude of the therapeutic loss as the dose rate increases and its sensitivity to changes in normal tissue and tumour parameter values is clearly demonstrated

  5. Brachytherapy dose measurements in heterogeneous tissues

    International Nuclear Information System (INIS)

    Paiva F, G.; Luvizotto, J.; Salles C, T.; Guimaraes A, P. C.; Dalledone S, P. de T.; Yoriyaz, H.; Rubo, R.

    2014-08-01

    Recently, Beau lieu et al. published an article providing guidance for Model-Based Dose Calculation Algorithms (MBDCAs), where tissue heterogeneity considerations are addressed. It is well-known that T G-43 formalism which considers only water medium is limited and significant dose differences have been found comparing both methodologies. The aim of the present work is to experimentally quantify dose values in heterogeneous medium using different dose measurement methods and techniques and compare them with those obtained with Monte Carlo simulations. Experiments have been performed using a Nucletron micro Selectron-Hdr Ir-192 brachytherapy source and a heterogeneous phantom composed by PMMA and different tissue equivalent cylinders like bone, lungs and muscle. Several dose measurements were obtained using tissue equivalent materials with height 1.8 cm and 4.3 cm positioned between the radiation source and the detectors. Radiochromic films, TLDs and MOSFET S have been used for the dose measurements. Film dosimetry has been performed using two methodologies: a) linearization for dose-response curve based on calibration curves to create a functional form that linearize s the dose response and b) 177 multichannel analysis dosimetry where the multiple color channels are analyzed allowing to address not only disturbances in the measurements caused by thickness variation in the film layer, but also, separate other external influences in the film response. All experiments have been simulated using the MCNP5 Monte Carlo radiation transport code. Comparison of experimental results are in good agreement with calculated dose values with differences less than 6% for almost all cases. (Author)

  6. Brachytherapy dose measurements in heterogeneous tissues

    Energy Technology Data Exchange (ETDEWEB)

    Paiva F, G.; Luvizotto, J.; Salles C, T.; Guimaraes A, P. C.; Dalledone S, P. de T.; Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Rubo, R., E-mail: gabrielpaivafonseca@gmail.com [Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, 05403-900 Sao Paulo (Brazil)

    2014-08-15

    Recently, Beau lieu et al. published an article providing guidance for Model-Based Dose Calculation Algorithms (MBDCAs), where tissue heterogeneity considerations are addressed. It is well-known that T G-43 formalism which considers only water medium is limited and significant dose differences have been found comparing both methodologies. The aim of the present work is to experimentally quantify dose values in heterogeneous medium using different dose measurement methods and techniques and compare them with those obtained with Monte Carlo simulations. Experiments have been performed using a Nucletron micro Selectron-Hdr Ir-192 brachytherapy source and a heterogeneous phantom composed by PMMA and different tissue equivalent cylinders like bone, lungs and muscle. Several dose measurements were obtained using tissue equivalent materials with height 1.8 cm and 4.3 cm positioned between the radiation source and the detectors. Radiochromic films, TLDs and MOSFET S have been used for the dose measurements. Film dosimetry has been performed using two methodologies: a) linearization for dose-response curve based on calibration curves to create a functional form that linearize s the dose response and b) 177 multichannel analysis dosimetry where the multiple color channels are analyzed allowing to address not only disturbances in the measurements caused by thickness variation in the film layer, but also, separate other external influences in the film response. All experiments have been simulated using the MCNP5 Monte Carlo radiation transport code. Comparison of experimental results are in good agreement with calculated dose values with differences less than 6% for almost all cases. (Author)

  7. Adjuvant high-dose-rate brachytherapy after external beam radiotherapy in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Oezyar, Enis; Yildz, Ferah; Akyol, Fadil H.; Atahan, I. Lale

    2002-01-01

    Purpose: To compare the local control and survival rates obtained with either external beam radiation therapy (ERT) and adjuvant high-dose-rate (HDR) brachytherapy (BRT) or ERT alone in patients with nasopharyngeal cancer. Methods and Materials: Between December 1993 and December 1999, 144 patients (106 male, 38 female) with the diagnosis of nasopharyngeal cancer were treated with either ERT and adjuvant HDR BRT (Group A) or ERT alone (Group B) at our department. BRT was not applied in 38 patients for the following reasons: (1) Unit was unavailable (n=13), (2) Patient was younger than 18 years (n=17), (3) Patient received accelerated hyperfractionated ERT (n=6), and (4) Patient refused BRT (n=2). The median age for whole group was 43 (range: 9-82 years). According to the AJCC-1997 staging system, there were 11 (7.6%), 35 (24.3%), 38 (26.4%), and 60 (41.7%) patients in Stage I, II, III, and IV, respectively. There were 57 (39.6%) patients with T1, 41 (28.5%) with T2, 20 (13.9%) with T3, and 26 (18.1%) with T4 tumors. Histopathologic diagnosis was WHO 2-3 in 137 (95.2%) patients. ERT doses ranged between 58.8 and 74 Gy (median: 66 Gy). There were significantly more patients with young age, N2 status, and Stage III disease in Group B and with Stage II disease in Group A. Significantly more patients received chemotherapy in Group B. BRT with an HDR 192 Ir microSelectron afterloading unit was delivered in 106 patients at the conclusion of ERT using a single-channel nasal applicator. Dose was prescribed at 1 cm from the source, and total dose of 12 Gy in 3 fractions on 3 consecutive days was given immediately after ERT. Besides radiotherapy, 82 (56.9%) patients received cisplatin-based chemotherapy, as well. Follow-up time ranged between 12 and 80 months (median: 32 months). Results: The two groups were comparable in terms of local recurrence, locoregional failure, regional failure, and rate of distant metastasis. Local failure was observed in 11 (10.3%) out of 106

  8. Patient effective dose from endovascular brachytherapy with 192Ir Sources

    International Nuclear Information System (INIS)

    Perna, L.; Bianchi, C.; Novario, R.; Nicolini, G.; Tanzi, F.; Conte, L.

    2002-01-01

    The growing use of endovascular brachytherapy has been accompanied by the publication of a large number of studies in several fields, but few studies on patient dose have been found in the literature. Moreover, these studies were carried out on the basis of Monte Carlo simulation. The aim of the present study was to estimate the effective dose to the patient undergoing endovascular brachytherapy treatment with 192 Ir sources, by means of experimental measurements. Two standard treatments were taken into account: an endovascular brachytherapy of the coronary artery corresponding to the activity x time product of 184 GBq.min and an endovascular brachytherapy of the renal artery (898 GBq.min). Experimental assessment was accomplished by thermoluminescence dosemeters positioned in more than 300 measurement points in a properly adapted Rando phantom. A method has been developed to estimate the mean organ doses for all tissues and organs concerned in order to calculate the effective dose associated with intravascular brachytherapy. The normalised organ doses resulting from coronary treatment were 2.4x10 -2 mSv.GBq -1 .min -1 for lung, 0.9x10 -2 mSv.GBq -1 .min -1 for oesophagus and 0.48x10 -2 mSv.GBq -1 .min -1 for bone marrow. During brachytherapy of the renal artery, the corresponding normalised doses were 4.2x10 -2 mSv.GBq -1 .min -1 for colon, 7.8x10 -2 mSv.GBq -1 .min -1 for stomach and 1.7x10 -2 mSv.GBq -1 .min -1 for liver. Coronary treatment involved an effective dose of 0.046 mSv.GBq -1 .min -1 , whereas the treatment of the renal artery resulted in an effective dose of 0.15 mSv.GBq -1 .min -1 ; there were many similarities with data from former studies. Based on these results it can be concluded that the dose level of patients exposed during brachytherapy treatment is low. (author)

  9. Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Samia de Freitas, E-mail: samiabrandao@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Campos, Tarcisio Passos Ribeiro de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2013-06-15

    Objective: comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and methods: simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results: intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h{sup -1}.p{sup -1}.s, respectively, on the healthy tissue, on the balloon periphery and on the /{sub 1} and /{sub 2} tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h{sup -1}.p{sup -1}.s, respectively on the healthy tissue, on the target tumor and on the /{sub 1} and /{sub 2} infiltration zones. Conclusion: Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones. (author)

  10. Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors

    Directory of Open Access Journals (Sweden)

    Samia de Freitas Brandao

    2013-07-01

    Full Text Available Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones.

  11. Inverse planning and class solutions for brachytherapy treatment planning

    International Nuclear Information System (INIS)

    Trnkova, P.

    2010-01-01

    Brachytherapy or interventional radiooncology is a method of radiation therapy. It is a method, where a small encapsulated radioactive source is placed near to / in the tumour and therefore delivers high doses directly to the target volume. Organs at risk (OARs) are spared due to the inverse square dose fall-off. In the past years there was a slight stagnation in the development of techniques for brachytherapy treatment. While external beam radiotherapy became more and more sophisticated, in brachytherapy traditional methods have been still used. Recently, 3D imaging was considered also as the modality for brachytherapy and more precise brachytherapy could expand. Nowadays, an image guided brachytherapy is state-of-art in many centres. Integration of imaging methods lead to the dose distribution individually tailored for each patient. Treatment plan optimization is mostly performed manually as an adaptation of a standard loading pattern. Recently, inverse planning approaches have been introduced into brachytherapy. The aim of this doctoral thesis was to analyze inverse planning and to develop concepts how to integrate inverse planning into cervical cancer brachytherapy. First part of the thesis analyzes the Hybrid Inverse treatment Planning and Optimization (HIPO) algorithm and proposes a workflow how to safely work with this algorithm. The problem of inverse planning generally is that only the dose and volume parameters are taken into account and spatial dose distribution is neglected. This fact can lead to unwanted high dose regions in a normal tissue. A unique implementation of HIPO into the treatment planning system using additional features enabled to create treatment plans similar to the plans resulting from manual optimization and to shape the high dose regions inside the CTV. In the second part the HIPO algorithm is compared to the Inverse Planning Simulated Annealing (IPSA) algorithm. IPSA is implemented into the commercial treatment planning system. It

  12. Gadolinium neutron capture brachytherapy (GdNCB), a new treatment method for intravascular brachytherapy

    International Nuclear Information System (INIS)

    Enger, Shirin A.; Rezaei, Arash; Munck af Rosenschoeld, Per; Lundqvist, Hans

    2006-01-01

    Restenosis is a major problem after balloon angioplasty and stent implantation. The aim of this study is to introduce gadolinium neutron capture brachytherapy (GdNCB) as a suitable modality for treatment of stenosis. The utility of GdNCB in intravascular brachytherapy (IVBT) of stent stenosis is investigated by using the GEANT4 and MCNP4B Monte Carlo radiation transport codes. To study capture rate, Kerma, absorbed dose and absorbed dose rate around a Gd-containing stent activated with neutrons, a 30 mm long, 5 mm diameter gadolinium foil is chosen. The input data is a neutron spectrum used for clinical neutron capture therapy in Studsvik, Sweden. Thermal neutron capture in gadolinium yields a spectrum of high-energy gamma photons, which due to the build-up effect gives an almost flat dose delivery pattern to the first 4 mm around the stent. The absorbed dose rate is 1.33 Gy/min, 0.25 mm from the stent surface while the dose to normal tissue is in order of 0.22 Gy/min, i.e., a factor of 6 lower. To spare normal tissue further fractionation of the dose is also possible. The capture rate is relatively high at both ends of the foil. The dose distribution from gamma and charge particle radiation at the edges and inside the stent contributes to a nonuniform dose distribution. This will lead to higher doses to the surrounding tissue and may prevent stent edge and in-stent restenosis. The position of the stent can be verified and corrected by the treatment plan prior to activation. Activation of the stent by an external neutron field can be performed days after catherization when the target cells start to proliferate and can be expected to be more radiation sensitive. Another advantage of the nonradioactive gadolinium stent is the possibility to avoid radiation hazard to personnel

  13. Role of TPS in 125I brachytherapy for orbital tumors

    International Nuclear Information System (INIS)

    Ren Ling; Dai Haojie; Li Quan

    2012-01-01

    Objective: To investigate the role of TPS in 125 I brachytherapy for orbital tumors. Methods: Sixty-six patients with orbital tumor treated with 125 I seeds from 2005 to 2009 were retrospectively analyzed. Forty-three patients were treated using TPS guided brachytherapy and the prescribed dose was 140 Gy. Other 23 patients were treated without TPS but simply implanted with 125 I seeds at 1 cm intervals in parallel with each other intraoperatively. CT and TPS quality verification were performed postoperatively in all patients. Also, CT and (or) MRI examination were performed at 3, 6, 12 and 24 months after brachytherapy for follow-up. χ 2 test and Kaplan-Meier survival analysis with log-rank significance test were used with SPSS 17.0. Results: A total of 1070 125 I seeds were implanted in 66 cases, on average, (16.2 ± 7.3) seeds for each patient. The satisfaction rates of postoperative quality verification in patients with and without TPS pre-plans were 79.07% (34/43) and 43.48% (10/23) respectively (χ 2 =8.542, P=0.003). Ten patients were lost in follow-up. Local recurrence rates in patients with favorable postoperative quality verification were 0 (0/37) in 3 months, 6.25% (2/32) in 6 months, 13.64% (3/22) in 12 months and 3/9 in 24 months respectively, which were significantly different from those (5.26% (1/19), 16.67% (3/18), 30.77% (4/13), 6/6) in the patients with inferior postoperative quality verification (χ 2 =9.017, P=0.0003). Conclusions: TPS plays an important role in 125 I brachytherapy for orbital tumors. Also, postoperative quality verification by TPS may help predict the local recurrence after brachytherapy. (authors)

  14. Results of the intestitial brachytherapy and of the combination external radiation-brachytherapy in 150 patients with carcinoma of the oral tongue and floor of the mouth

    International Nuclear Information System (INIS)

    Sannazzari, G.L.; Negri, G.L.; Ozzello, F.

    1986-01-01

    The authors report their experience on the treatment of carcinoma of the oral tongue and floor of the mouth with interstitial brachytherapy, alone or in conbination with external irradiation. One hundred and fifty patients were treated; among these, 116 with brachytherapy alone, 34 with combined treatment. The five years local control in those patients treated with brachytherapy alone was 72.5% in T1, 61.2% in T2 and 35% in T3; in those patients treated with external irradiation and brachytherapy the global five years control was 42.5%. The global five years survival was 64% in the patients treated with brachytherapy alone 48% in the patients treated with combined therapy

  15. Results of the intestitial brachytherapy and of the combination external radiation-brachytherapy in 150 patients with carcinoma of the oral tongue and floor of the mouth

    Energy Technology Data Exchange (ETDEWEB)

    Sannazzari, G L; Negri, G L; Ozzello, F

    1986-01-01

    The authors report their experience on the treatment of carcinoma of the oral tongue and floor of the mouth with interstitial brachytherapy, alone or in conbination with external irradiation. One hundred and fifty patients were treated; among these, 116 with brachytherapy alone, 34 with combined treatment. The five years local control in those patients treated with brachytherapy alone was 72.5% in T1, 61.2% in T2 and 35% in T3; in those patients treated with external irradiation and brachytherapy the global five years control was 42.5%. The global five years survival was 64% in the patients treated with brachytherapy alone 48% in the patients treated with combined therapy. 42 refs.

  16. Brachytherapy in head and neck cancers; Curietherapie des cancers de la sphere ORL

    Energy Technology Data Exchange (ETDEWEB)

    Mazeron, J.J.; Noel, G.; Simon, J.M.; Racadot, S.; Jauffret, E. [Groupe Hospitalier la Pitie-Salpetriere, Centre des Tumeurs, 75 - Paris (France)

    2003-02-01

    Experience accumulated over several decades with radiation of Head and Neck tumours by irradiation has demonstrated the need for a high tumour dose to achieve local control. With external beam irradiation alone, it is difficult to spare adjacent normal tissues, resulting in undesirable late effects on the salivary glands; mandible, and muscles of mastication. Interstitial implantation is ideally suited to deliver a high dose limited to the volume of the primary tumor, thus minimizing sequels. A large experience has been accumulated with low dose rate (LDR) brachytherapy in treatment of carcinoma of oral cavity, oropharynx, and nasopharynx. Recent analysis of large clinical series provided data indicating that modalities of low dose rate brachytherapy should be optimized in treating these tumors for increasing therapeutic ratio. Low dose rate brachytherapy is now challenged by high dose rate (HDR) brachytherapy and pulsed dose rate (PDR) brachytherapy. Preliminary results obtained with these two last modalities are discussed regarding to those of low dose rate brachytherapy. (authors)

  17. Utilization of prostate brachytherapy for low risk prostate cancer: Is the decline overstated?

    OpenAIRE

    Joseph Safdieh; Andrew Wong; Joseph P. Weiner; David Schwartz; David Schreiber

    2016-01-01

    Purpose : Several prior studies have suggested that brachytherapy utilization has markedly decreased, coinciding with the recent increased utilization of intensity modulated radiation therapy, as well as an increase in urologist-owned centers. We sought to investigate the brachytherapy utilization in a large, hospital-based registry. Material and methods: Men with prostate cancer diagnosed between 2004-2012 and treated with either external beam radiation and/or prostate brachytherapy ...

  18. Toward a 'all high rate' brachytherapy: organisation, biology and perspectives after treatment of 192 patients

    International Nuclear Information System (INIS)

    Hannoun-Levi, J.M.; Ferre, M.; Gautier, M.; Marcie, S.

    2007-01-01

    As a result of radiation protection regulations aimed at reducing the exposure to ionizing radiation from care-givers, low dose rate brachytherapy is usually replaced by a pulsed rate brachytherapy. The center Antoine Lacassagne has directed the outset to the use of a high-dose rate brachytherapy. The implications in terms of organization, biology and the prospects for such a change are the principal questions studied. (N.C.)

  19. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: An electronic brachytherapy source

    International Nuclear Information System (INIS)

    Rivard, Mark J.; Davis, Stephen D.; DeWerd, Larry A.; Rusch, Thomas W.; Axelrod, Steve

    2006-01-01

    A new x-ray source, the model S700 Axxent trade mark sign X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, P (5) were 0.20, 0.24, and 0.29 for the 40, 45, and 50 kV voltage settings, respectively. For 1 125 I and 103 Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages

  20. Image guided, adaptive, accelerated, high dose brachytherapy as model for advanced small volume radiotherapy

    International Nuclear Information System (INIS)

    Haie-Meder, Christine; Siebert, Frank-Andre; Poetter, Richard

    2011-01-01

    Brachytherapy has consistently provided a very conformal radiation therapy modality. Over the last two decades this has been associated with significant improvements in imaging for brachytherapy applications (prostate, gynecology), resulting in many positive advances in treatment planning, application techniques and clinical outcome. This is emphasized by the increased use of brachytherapy in Europe with gynecology as continuous basis and prostate and breast as more recently growing fields. Image guidance enables exact knowledge of the applicator together with improved visualization of tumor and target volumes as well as of organs at risk providing the basis for very individualized 3D and 4D treatment planning. In this commentary the most important recent developments in prostate, gynecological and breast brachytherapy are reviewed, with a focus on European recent and current research aiming at the definition of areas for important future research. Moreover the positive impact of GEC-ESTRO recommendations and the highlights of brachytherapy physics are discussed what altogether presents a full overview of modern image guided brachytherapy. An overview is finally provided on past and current international brachytherapy publications focusing on 'Radiotherapy and Oncology'. These data show tremendous increase in almost all research areas over the last three decades strongly influenced recently by translational research in regard to imaging and technology. In order to provide high level clinical evidence for future brachytherapy practice the strong need for comprehensive prospective clinical research addressing brachytherapy issues is high-lighted.

  1. dose in cervical cancer intracavitary brachytherapy

    Directory of Open Access Journals (Sweden)

    Zahra Siavashpour

    2016-04-01

    Full Text Available Purpose: To analyze the optimum organ filling point for organs at risk (OARs dose in cervical cancer high-dose-rate (HDR brachytherapy. Material and methods : In a retrospective study, 32 locally advanced cervical cancer patients (97 insertions who were treated with 3D conformal external beam radiation therapy (EBRT and concurrent chemotherapy during 2010-2013 were included. Rotterdam HDR tandem-ovoid applicators were used and computed tomography (CT scanning was performed after each insertion. The OARs delineation and GEC-ESTRO-based clinical target volumes (CTVs contouring was followed by 3D forward planning. Then, dose volume histogram (DVH parameters of organs were recorded and patients were classified based on their OARs volumes, as well as their inserted tandem length. Results : The absorbed dose to point A ranged between 6.5-7.5 Gy. D 0.1cm ³ and D 2cm ³ of the bladder significantly increased with the bladder volume enlargement (p value < 0.05. By increasing the bladder volume up to about 140 cm3, the rectum dose was also increased. For the cases with bladder volumes higher than 140 cm3, the rectum dose decreased. For bladder volumes lower than 75 cm3, the sigmoid dose decreased; however, for bladder volumes higher than 75 cm3, the sigmoid dose increased. The D 2cm ³ of the bladder and rectum were higher for longer tandems than for shorter ones, respectively. The divergence of the obtained results for different tandem lengths became wider by the extension of the bladder volume. The rectum and sigmoid volume had a direct impact on increasing their D 0.1cm ³ and D 2cm ³, as well as decreasing their D 10 , D 30 , and D 50 . Conclusions : There is a relationship between the volumes of OARs and their received doses. Selecting a bladder with a volume of about 70 cm3 or less proved to be better with regards to the dose to the bladder, rectum, and sigmoid.

  2. Brachytherapy radiation doses to the neurovascular bundles

    International Nuclear Information System (INIS)

    Di Biase, Steven J.; Wallner, Kent; Tralins, Kevin; Sutlief, Steven

    2000-01-01

    Purpose: To investigate the role of radiation dose to the neurovascular bundles (NVB) in brachytherapy-related impotence. Methods and Materials: Fourteen Pd-103 or I-125 implant patients were studied. For patients treated with implant alone, the prostate and margin (clinical target volume [CTV]) received a prescription dose of 144 Gy for I-125 or 115 Gy for Pd-103. Two patients received Pd-103 (90 Gy) with 46 Gy supplemental external beam radiation (EBRT). Axial CT images were acquired 2 to 4 hours postoperatively for postimplant dosimetry. Because the NVBs cannot be visualized on CT, NVB calculation points were determined according to previously published anatomic descriptions. Bilateral NVB points were considered to lie posterior-laterally, approximately 2 mm from the prostatic capsule. NVB doses were recorded bilaterally, at 0.5-cm intervals from the prostatic base. Results: For Pd-103, the average NVB doses ranged from 150 Gy to 260 Gy, or 130% to 226% of the prescription dose. For I-125, the average NVB dose ranged from 200 Gy to 325 Gy, or 140% to 225% of the prescription dose. These was no consistent relationship between the NVB dose and the distance from the prostatic base. To examine the possible effect of minor deviations of our calculation points from the true NVB location, we performed NVB calculations at points 2 mm medial or lateral from the NVB calculation point in 8 patients. Doses at these alternate calculation points were comparable, although there was greater variability with small changes in the calculation point if sources were located outside the capsule, near the NVB calculation point. Three patients who developed early postimplant impotence had maximal NVB doses that far exceeded the average values. Conclusions: In the next few years, we hope to clarify the role of high NVB radiation doses on potency, by correlating NVB dose calculations with a large number of patients enrolled in an ongoing I-125 versus Pd-103 trial for early-stage patients

  3. Conformational episcleral brachytherapy in ocular tumors

    International Nuclear Information System (INIS)

    Goset, Karen; Barriga, Hernan; Guevara, Juan; Zelada, Gabriel; Badinez, Leonardo; Gonzalez, German

    2000-01-01

    Brachytherapy with an episcleral plate is an alternative treatment for choroid melanomas and retinoblastomas that allows the sight to be saved. The most common techniques use a metal applicator with beta or Co-60 transmitters, which have a standard geometry, require surgical installation of the active devices and do not allow optimized dosimetry. In 1997, the Clinica Alemana in Santiago, Chile, developed a new device based on the one described by J.P. Gerard (1988), with plastic material, personalized and with delayed charge. Three cases have been treated. Two retinoblastomas: 1) Primary treatment in unilateral Rb, R.E. group II in a 9 month old boy, 2) External post radiotherapy rescue in oculus ultimus by bilateral Rb in a 10 year old girl, and 3) Choroid melanoma T3N0M0 in a 77 year old woman. A personalized applicator was prepared in each case depending on the size and location of the tumor. The distribution of the vector catheters was designed following the Paris system standards. The applicator was inserted in the operating room, under general anesthesia by a team of trained ophthalmologists. An X-ray and helichoidal simulation scan were taken with fictitious sources. Previsional dosimetry was undertaken, with evaluation of the dosage to the tumor apex, crystalline lens, sclera and optic nerve. Prolonged activation with low level dosage Ir-192 wires was performed in a protected room. When the programmed dosage was completed, the sources and then the inactive applicator were removed. Dosage: A 40 Gy dose was applied in the retinoblastoma to the tumor apex and 60 Gy to the melanoma, over a 2 to 3 day period. Tolerance was excellent, there were no incidents or acute complications. The retinoblastomas fully regressed in 1 to 2 weeks, with no local relapse or after affects after 2, 4 and 6 months of follow-up. The 3 patients have retained their sight. The development of this technique is feasible and with enough resources, relatively easy to implement. It has

  4. Dosimetric comparison between intensity modulated brachytherapy versus external beam intensity modulated radiotherapy for cervix cancer: a treatment planning study

    International Nuclear Information System (INIS)

    Subramani, V.; Sharma, D.N.; Jothy Basu, K.S.; Rath, G.K.; Gopishankar, N.

    2008-01-01

    To evaluate the dosimetric superiority of intensity modulated brachytherapy (IMBT) based on inverse planning optimization technique with classical brachytherapy optimization and also with external beam intensity modulated radiotherapy planning technique in patients of cervical carcinoma

  5. Remote possibilities

    International Nuclear Information System (INIS)

    Fernandes, J.

    1995-01-01

    The impact that wireless communications has had for gas and oil producers was discussed. Wireless communication, which has been replacing the traditional formats of radio and telephone data networks, has proved to be cheaper, smaller, and faster than creating privately owned communication networks. With highly developed supervisory control and data acquisition systems - combined with cellular or satellite technology - information from drill sites can be online at the corporate headquarters instantaneously. Eighty percent of Canada's land mass is beyond reach of traditional wireline and wireless services. Research into advanced communications, including telecommunication and mobile applications, yielded lucrative results for service providers such as BCTel, SaskTel, Bell Mobility and AGT. The latest data transmission technology is the cellular digital packet data (CDPD) which will operate over existing cellular networks. However, unlike circuit-switched cellular, CDPD technology provides an airlink where data is secure. It will be available to the marketplace over the course of the coming year. Among other advantages, CDPD will allow producers to remotely monitor production information and downtime alarms from wells and compressor stations. It will also provide fleet operators with the means to monitor operating vital signs on rolling stock

  6. Trends in the Utilization of Brachytherapy in Cervical Cancer in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Han, Kathy, E-mail: Kathy.Han@rmp.uhn.on.ca [Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, Ontario (Canada); Milosevic, Michael; Fyles, Anthony [Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, Ontario (Canada); Pintilie, Melania [Department of Biostatistics, Princess Margaret Hospital, Toronto, Ontario (Canada); Viswanathan, Akila N. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, Massachusetts (United States)

    2013-09-01

    Purpose: To determine the trends in brachytherapy use in cervical cancer in the United States and to identify factors and survival benefits associated with brachytherapy treatment. Methods and Materials: Using the Surveillance, Epidemiology, and End Results (SEER) database, we identified 7359 patients with stages IB2-IVA cervical cancer treated with external beam radiation therapy (EBRT) between 1988 and 2009. Propensity score matching was used to adjust for differences between patients who received brachytherapy and those who did not from 2000 onward (after the National Cancer Institute alert recommending concurrent chemotherapy). Results: Sixty-three percent of the 7359 women received brachytherapy in combination with EBRT, and 37% received EBRT alone. The brachytherapy utilization rate has decreased from 83% in 1988 to 58% in 2009 (P<.001), with a sharp decline of 23% in 2003 to 43%. Factors associated with higher odds of brachytherapy use include younger age, married (vs single) patients, earlier years of diagnosis, earlier stage and certain SEER regions. In the propensity score-matched cohort, brachytherapy treatment was associated with higher 4-year cause-specific survival (CSS; 64.3% vs 51.5%, P<.001) and overall survival (OS; 58.2% vs 46.2%, P<.001). Brachytherapy treatment was independently associated with better CSS (hazard ratio [HR], 0.64; 95% confidence interval [CI], 0.57-0.71), and OS (HR 0.66; 95% CI, 0.60 to 0.74). Conclusions: This population-based analysis reveals a concerning decline in brachytherapy utilization and significant geographic disparities in the delivery of brachytherapy in the United States. Brachytherapy use is independently associated with significantly higher CSS and OS and should be implemented in all feasible cases.

  7. Perioperative high dose rate (HDR brachytherapy in unresectable locally advanced pancreatic tumors

    Directory of Open Access Journals (Sweden)

    Brygida Białas

    2011-07-01

    Full Text Available Purpose: The aim of the study was to present an original technique of catheter implantation for perioperative HDR-Ir192 brachytherapy in patients after palliative operations of unresectable locally advanced pancreatic tumors and to estimate the influence of perioperative HDR-Ir192 brachytherapy on pain relief in terminal pancreatic cancer patients. Material and methods: Eight patients with pancreatic tumors located in the head of pancreas underwent palliative operations with the use of HDR-Ir192 brachytherapy. All patients qualified for surgery reported pain of high intensity and had received narcotic painkillers prior to operation. During the last phase of the surgery, the Nucletron® catheters were implanted in patients to prepare them for later perioperative brachytherapy. Since the 6th day after surgery HDR brachytherapy was performed. Before each brachytherapy fraction the location of implants were checked using fluoroscopy. A fractional dose was 5 Gy and a total dose was 20 Gy in the area of radiation. A comparative study of two groups of patients (with and without brachytherapy with stage III pancreatic cancer according to the TNM scale was taken in consideration. Results and Conclusions: The authors claim that the modification of catheter implantation using specially designed cannula, facilitates the process of inserting the catheter into the tumor, shortens the time needed for the procedure, and reduces the risk of complications. Mean survival time was 5.7 months. In the group of performed brachytherapy, the mean survival time was 6.7 months, while in the group of no brachytherapy performed – 4.4 months. In the group of brachytherapy, only one patient increased the dose of painkillers in the last month of his life. Remaining patients took constant doses of medicines. Perioperative HDR-Ir192 brachytherapy could be considered as a practical application of adjuvant therapy for pain relief in patients with an advanced pancreatic cancer.

  8. Dependence of early therapy results and complications on radiation dose values and their fractionation in pre-operative ''afterloading'' technique brachyradiotherapy applied to cervix uteri carcinoma patients

    International Nuclear Information System (INIS)

    Kaminska, G.; Kawczynska, M.

    1984-01-01

    The ''afterloading'' technique with use of Curietron (41 cases) or Selectron (43 cases) apparatus was applied in 83 cervix uteri carcinoma patients in phase 1b (79 cases) and 2a (4 cases). The Wertheim-Magis operation was performed after several weeks. Post-operative histologic investigation showed complete destruction of the tumour in 72% cases; persistent cancer cells in cervix uteri were stated in 11 patients (13%), while lymphatic node metastasis was seen in 14 patients (17%). Supplementary teleradiotherapy was performed in those cases. 39 patients (95%) of the 41 observed during 3 years survived without any cancer symptoms. No explicit relationship between dose administered to vaginal disc and cancer persistence frequency in the cervix uteri was stated. However, such relationship was stated for the dose in point A. In the group of 19 patients who received point A dose of the least 6000 rads, with average TDF value of 135, presence of cancer cells in cervix uteri was not stated in any of the cases. In 7 patients (17%) observed for over 3 years light and medium heavy postradiation complications were stated; in that 5 rectum side complications were stated in patients additionally irradiated from external fields, where the dose absorbed by rectum wall exceeded 8000 rads, with TDF - 150. No complications were observed when the dose was less than 5000 rads and TDF below 100. 16 refs., 1 fig. (author)

  9. Routine quality control of high dose rate brachytherapy equipment

    International Nuclear Information System (INIS)

    Guzman Calcina, Carmen S.; Almeida, Adelaide de; Rocha, Jose R. Oliveira

    2001-01-01

    A Quality Assurance program should be installed also for High Dose Rate brachytherapy, in the order to achieve a correct dose administration to the patient and for the safety to those involved directly with the treatment. The work presented here has the following purposes: Analyze the types of equipment tests presented by the official protocols (TG40, TG56 e ARCAL XXX), evaluate the brachytherapy routine tests of protocols from various national and international radiotherapy services and compare the latter with those presented in the official protocols. As a result, we conclude the following: TG56 presents a higher number of tests when compared to the other official protocols and most of the tests presented by the analyzed services are present in TG56. A suggestion for a basic protocol is presented, emphasizing the periodicity and tolerance level of each of the tests. (author)

  10. Brachytherapy: The need for a national metrology lab in Spain

    International Nuclear Information System (INIS)

    Aviles Lucas, P.

    2011-01-01

    Radiotherapy, along with chemotherapy and surgery, is an essential therapeutic technique for treating malignant tumours. Part of the challenge of a suitable radiotherapy treatment lies on the optimisation of the irradiated volume, which must be adapted to the tumour volume as far as possible. Depending on position of the radiation source relative to the patient, the procedure in question could be external radiotherapy, or brachytherapy. In a brachytherapy procedure, relatively small encapsulated radioactive sources are placed close to or in the tumour volume to be treated. This therapeutic treatment has two obvious advantages; on one hand the prescribed dose can be adjusted to the tumour volume, preventing unnecessary exposure of the adjacent healthy tissues, and on the other, it decreases the treatment duration compared to a radiotherapy treatment. (Author) 19 refs.

  11. Dose calculation and isodose curves determination in brachytherapy

    International Nuclear Information System (INIS)

    Maranhao, Frederico B.; Lima, Fernando R.A.; Khoury, Helen J.

    2000-01-01

    Brachytherapy is a form of cancer treatment in which small radioactive sources are placed inside of, or close to small tumors, in order to cause tissue necrosis and, consequently, to interrupt the tumor growth process. A very important aspect to the planning of this therapy is the calculation of dose distributions in the tumor and nearby tissues, to avoid the unnecessary irradiation of healthy tissue. The objective of this work is to develop a computer program that will permit treatment planning for brachytherapy at low dose rates, minimizing the possible errors introduced when such calculations are done manually. Results obtained showed good agreement with those from programs such as BRA, which is widely used in medical practice. (author)

  12. Cervical cancer. Application of MR imaging in brachytherapy

    International Nuclear Information System (INIS)

    Ebe, Kazuyu; Matsunaga, Naofumi

    1996-01-01

    For the purpose of application of MRI in arrangement of brachytherapy of cervical cancer, a method was proposed to see the radiation doses in surrounding tissues by superimposing the dose distribution pattern of the radiation source on the MR image. The applicator for the source was filled with water to get its T2-weighted image and was inserted in the patients. The MRI apparatus was Siemens Magnetom Vision (1.5T) with phased array coil. T2-weighted sagittal and coronary images were taken by turbospin echo and HASTE methods. The section thickness was 5 mm. The dose distribution pattern was superimposed on the frontal and lateral images by Siemens Mevaplan to see the doses in surrounding tissues. In 4 patients, it was possible to estimate the radiation dose in the posterior wall of bladder, anterior wall of rectum and urinary duct. The method is promising for arranging brachytherapy of cervical cancer. (K.H.)

  13. Brachytherapy for coronary restenosis: state of art in 2003

    International Nuclear Information System (INIS)

    Latorzeff, I.; Delannes, M.; Latorzeff, I.; Carrie, D.; Alibelli, M.J.; Bonnet, J.; Duthil, P.

    2003-01-01

    Based on therapeutic approach for benign diseases, vascular brachytherapy decreases smooth vascular muscle cells proliferation and multiplication which lead to the formation of the neo-intima. The radioactive positive action affects arterial recoil due to post angioplasty vessel injury. Randomized studies has shown good angiographic results up to 6 months of follow-up, with 50% in-stent restenosis rate decrease and on the analysed segment as well. Decrease on Mace and TLR show statistically significance. Results don't correlate with emitter and beta emitters had been introduced in France recently. Vascular brachytherapy is actually indicated for in-stent restenosis, there is no evidence to perform this treatment for de novo lesion. Geographic miss, source centering, late thrombosis and pullback procedure may interfere with treatment quality. IVUS allows best target volume determination to a higher quality level. Internationals guidelines such as Eva-Gec-Estro recommendations could increase treatment safety and enable development of an optimal technique. (authors)

  14. Brachytherapy for prostate cancer: Comparative characteristics of procedures

    Directory of Open Access Journals (Sweden)

    S. V. Kanaev

    2015-01-01

    Full Text Available The introduction of interstitial radiation sources is the «youngest» of the radical method of treatment of patients with prostate cancer (PC. The high level of efficiency comparable to prostatectomy at a significantly lower rate of complications causes rapid growth of clinical use of brachytherapy (BT. Depending on the radiation source and the mode of administration into the prostate gland are two types BT – high-dose rate (temporary (HDR-BT and low-dose rate (permanent (LDR-BT brachytherapy. At the heart of these two methods are based on a single principle of direct effect of the quantum gamma radiation on the area of interest. However, the differences between the characteristics of isotopes used and technical aspects of the techniques cause the difference in performance and complication rates for expression HDR-BT and LDR-BT.

  15. Photon energy-fluence correction factor in low energy brachytherapy

    International Nuclear Information System (INIS)

    Antunes, Paula C.G.; Yoriyaz, Hélio; Vijande, Javier; Giménez-Alventosa, Vicent; Ballester, Facundo

    2017-01-01

    The AAPM TG-43 brachytherapy dosimetry formalism has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so that the absorbed dose in the two media can be related by their ratio of mass energy-absorption coefficients. The purpose of this work is to study the influence of photon energy-fluence in different media and to evaluate a proposal for energy-fluence correction factors for the conversion between dose-to-tissue (D tis ) and dose-to-water (D w ). State-of-the art Monte Carlo (MC) calculations are used to score photon fluence differential in energy in water and in various human tissues (muscle, adipose and bone) in two different codes, MCNP and PENELOPE, which in all cases include a realistic modeling of the 125 I low-energy brachytherapy seed in order to benchmark the formalism proposed. A correction is introduced that is based on the ratio of the water-to-tissue photon energy-fluences using the large-cavity theory. In this work, an efficient way to correlate absorbed dose to water and absorbed dose to tissue in brachytherapy calculations at clinically relevant distances for low-energy photon emitting seed is proposed. The energy-fluence based corrections given in this work are able to correlate absorbed dose to tissue and absorbed dose to water with an accuracy better than 0.5% in the most critical cases. (author)

  16. Brachytherapy in Lip Carcinoma: Long-Term Results

    Energy Technology Data Exchange (ETDEWEB)

    Guibert, Mireille, E-mail: mireilleguib@voila.fr [Department of Head and Neck Surgery, Larrey Hospital, Toulouse (France); David, Isabelle [Department of Radiation Oncology, Claudius Regaud Institut, Toulouse (France); Vergez, Sebastien [Department of Head and Neck Surgery, Larrey Hospital, Toulouse (France); Rives, Michel [Department of Radiation Oncology, Claudius Regaud Institut, Toulouse (France); Filleron, Thomas [Department of Epidemiology, Claudius Regaud Institut, Toulouse (France); Bonnet, Jacques; Delannes, Martine [Department of Radiation Oncology, Claudius Regaud Institut, Toulouse (France)

    2011-12-01

    Purpose: The aim of this study was to evaluate the effectiveness of low-dose-rate brachytherapy for local control and relapse-free survival in squamous cell and basal cell carcinomas of the lips. We compared two groups: one with tumors on the skin and the other with tumors on the lip. Patients and methods: All patients had been treated at Claudius Regaud Cancer Centre from 1990 to 2008 for squamous cell or basal cell carcinoma. Low-dose-rate brachytherapy was performed with iridium 192 wires according to the Paris system rules. On average, the dose delivered was 65 Gy. Results: 172 consecutive patients were included in our study; 69 had skin carcinoma (squamous cell or basal cell), and 92 had squamous cell mucosal carcinoma. The average follow-up time was 5.4 years. In the skin cancer group, there were five local recurrences and one lymph node recurrence. In the mucosal cancer group, there were ten local recurrences and five lymph node recurrences. The 8-year relapse-free survival for the entire population was 80%. The 8-year relapse-free survival was 85% for skin carcinoma 75% for mucosal carcinoma, with no significant difference between groups. The functional results were satisfactory for 99% of patients, and the cosmetic results were satisfactory for 92%. Maximal toxicity observed was Grade 2. Conclusions: Low-dose-rate brachytherapy can be used to treat lip carcinomas at Stages T1 and T2 as the only treatment with excellent results for local control and relapse-free survival. The benefits of brachytherapy are also cosmetic and functional, with 91% of patients having no side effects.

  17. Photon energy-fluence correction factor in low energy brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Antunes, Paula C.G.; Yoriyaz, Hélio [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Vijande, Javier; Giménez-Alventosa, Vicent; Ballester, Facundo, E-mail: pacrisguian@gmail.com [Department of Atomic, Molecular, and Nuclear Physics and Instituto de Física Corpuscular (UV-CSIC), University of Valencia (Spain)

    2017-07-01

    The AAPM TG-43 brachytherapy dosimetry formalism has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so that the absorbed dose in the two media can be related by their ratio of mass energy-absorption coefficients. The purpose of this work is to study the influence of photon energy-fluence in different media and to evaluate a proposal for energy-fluence correction factors for the conversion between dose-to-tissue (D{sub tis}) and dose-to-water (D{sub w}). State-of-the art Monte Carlo (MC) calculations are used to score photon fluence differential in energy in water and in various human tissues (muscle, adipose and bone) in two different codes, MCNP and PENELOPE, which in all cases include a realistic modeling of the {sup 125}I low-energy brachytherapy seed in order to benchmark the formalism proposed. A correction is introduced that is based on the ratio of the water-to-tissue photon energy-fluences using the large-cavity theory. In this work, an efficient way to correlate absorbed dose to water and absorbed dose to tissue in brachytherapy calculations at clinically relevant distances for low-energy photon emitting seed is proposed. The energy-fluence based corrections given in this work are able to correlate absorbed dose to tissue and absorbed dose to water with an accuracy better than 0.5% in the most critical cases. (author)

  18. Ocular brachytherapy with a holmium-166 irradiator device

    Energy Technology Data Exchange (ETDEWEB)

    Mourao, Arnaldo P. [Centro Federal de Educacao Tecnoloica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar], e-mail: aprata@des.cefetmg.br; Campos, Tarcisio P.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares], e-mail: campos@nuclear.ufmg.br

    2009-07-01

    The ocular brachytherapy is a method that allows controlling ocular tumors. However, the irradiation of the ocular area in high doses can bring damages mainly to the surrounding healthy tissue, such as lens, retina and bone tissue of the orbital area in growth phase. Brachytherapy in comparison to teletherapy allows a large reduction of the absorbed doses in the adjacent tissues avoiding deleterious effects. Various types of radionuclides can be applied to ocular brachytherapy. Those radionuclides shall be encapsulated and placed juxtaposed to the sclera, back to the tumor. Herein, a new device was developed to encapsulate the radioactive material. It can easily place back of the eyeball. A computational model of the ocular area was developed in order to simulate the spatial dose distribution promoted by the holmium-166 nuclide distributed inside the irradiator device. The simulations addressed a device placed on the surface of the sclera, rotated 90 deg taken at the normal axis forward to the lens. The simulation was carried on the code Monte Carlo MCNP5. The computational simulation generates the spatial dose distribution in the treated volume. All continuous beta and the discrete gamma and X-ray spectra emitted by the holmium-166 were incorporated on simulations. The results allow comparing the space dose distribution to other types of sources used for the same end. The sclera absorbed dose, the maximum apical tumor dose, as well as on the tumor base were investigated. Indeed, the tumor thickness defines the conditions of irradiation. The holmium-166 dose distribution provides a tool to propose a better and optimized protocol for ocular brachytherapy. (author)

  19. Study of two different radioactive sources for prostate brachytherapy treatment

    International Nuclear Information System (INIS)

    Pereira Neves, Lucio; Perini, Ana Paula; Souza Santos, William de; Caldas, Linda V.E.; Belinato, Walmir

    2015-01-01

    In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a 192 Ir and a 125 I radioactive sources. The 192 Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The 125 I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of an adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of 125 I and one of 192 Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the 192 Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the 125 I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)

  20. Study of two different radioactive sources for prostate brachytherapy treatment

    Energy Technology Data Exchange (ETDEWEB)

    Pereira Neves, Lucio; Perini, Ana Paula [Instituto de Fisica, Universidade Federal de Uberlandia, Caixa Postal 593, 38400-902, Uberlandia, MG (Brazil); Souza Santos, William de; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, IPENCNEN/SP, Av. Prof. Lineu Prestes, 2242, Cidade Universitaria, 05508-000 Sao Paulo, SP (Brazil); Belinato, Walmir [Departamento de Ensino, Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia, Campus Vitoria da Conquista, Zabele, Av. Amazonas 3150, 45030-220 Vitoria da Conquista, BA (Brazil)

    2015-07-01

    In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a {sup 192}Ir and a {sup 125}I radioactive sources. The {sup 192}Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The {sup 125}I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of an adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of {sup 125}I and one of {sup 192}Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the {sup 192}Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the {sup 125}I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)

  1. Serum Testosterone Kinetics After Brachytherapy for Clinically Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Taira, Al V.; Merrick, Gregory S.; Galbreath, Robert W.; Butler, Wayne M.; Lief, Jonathan H.; Allen, Zachariah A.; Wallner, Kent E.

    2012-01-01

    Purpose: To evaluate temporal changes in testosterone after prostate brachytherapy and investigate the potential impact of these changes on response to treatment. Methods and Materials: Between January 2008 and March 2009, 221 consecutive patients underwent Pd-103 brachytherapy without androgen deprivation for clinically localized prostate cancer. Prebrachytherapy prostate-specific antigen (PSA) and serum testosterone were obtained for each patient. Repeat levels were obtained 3 months after brachytherapy and at least every 6 months thereafter. Multiple clinical, treatment, and dosimetric parameters were evaluated to determine an association with temporal testosterone changes. In addition, analysis was conducted to determine if there was an association between testosterone changes and treatment outcomes or the occurrence of a PSA spike. Results: There was no significant difference in serum testosterone over time after implant (p = 0.57). 29% of men experienced an increase ≥25%, 23% of men experienced a decrease ≥25%, and the remaining 48% of men had no notable change in testosterone over time. There was no difference in testosterone trends between men who received external beam radiotherapy and those who did not (p = 0.12). On multivariate analysis, preimplant testosterone was the only variable that consistently predicted for changes in testosterone over time. Men with higher than average testosterone tended to experience drop in testosterone (p < 0.001), whereas men with average or below average baseline testosterone had no significant change. There was no association between men who experienced PSA spike and testosterone temporal trends (p = 0.50) nor between initial PSA response and testosterone trends (p = 0.21). Conclusion: Prostate brachytherapy does not appear to impact serum testosterone over time. Changes in serum testosterone do not appear to be associated with PSA spike phenomena nor with initial PSA response to treatment; therefore, PSA response

  2. Fully automated MRI-guided robotics for prostate brachytherapy

    International Nuclear Information System (INIS)

    Stoianovici, D.; Vigaru, B.; Petrisor, D.; Muntener, M.; Patriciu, A.; Song, D.

    2008-01-01

    The uncertainties encountered in the deployment of brachytherapy seeds are related to the commonly used ultrasound imager and the basic instrumentation used for the implant. An alternative solution is under development in which a fully automated robot is used to place the seeds according to the dosimetry plan under direct MRI-guidance. Incorporation of MRI-guidance creates potential for physiological and molecular image-guided therapies. Moreover, MRI-guided brachytherapy is also enabling for re-estimating dosimetry during the procedure, because with the MRI the seeds already implanted can be localised. An MRI compatible robot (MrBot) was developed. The robot is designed for transperineal percutaneous prostate interventions, and customised for fully automated MRI-guided brachytherapy. With different end-effectors, the robot applies to other image-guided interventions of the prostate. The robot is constructed of non-magnetic and dielectric materials and is electricity free using pneumatic actuation and optic sensing. A new motor (PneuStep) was purposely developed to set this robot in motion. The robot fits alongside the patient in closed-bore MRI scanners. It is able to stay fully operational during MR imaging without deteriorating the quality of the scan. In vitro, cadaver, and animal tests showed millimetre needle targeting accuracy, and very precise seed placement. The robot tested without any interference up to 7T. The robot is the first fully automated robot to function in MRI scanners. Its first application is MRI-guided seed brachytherapy. It is capable of automated, highly accurate needle placement. Extensive testing is in progress prior to clinical trials. Preliminary results show that the robot may become a useful image-guided intervention instrument. (author)

  3. Serum Testosterone Kinetics After Brachytherapy for Clinically Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Taira, Al V. [Western Radiation Oncology, Mountain View, CA (United States); Merrick, Gregory S., E-mail: gmerrick@urologicresearchinstitute.org [Schiffler Cancer Center, Wheeling Jesuit University, Wheeling, WV (United States); Galbreath, Robert W.; Butler, Wayne M.; Lief, Jonathan H.; Allen, Zachariah A. [Schiffler Cancer Center, Wheeling Jesuit University, Wheeling, WV (United States); Wallner, Kent E. [Puget Sound Healthcare Corporation Group Health Cooperative, University of Washington, Seattle, WA (United States)

    2012-01-01

    Purpose: To evaluate temporal changes in testosterone after prostate brachytherapy and investigate the potential impact of these changes on response to treatment. Methods and Materials: Between January 2008 and March 2009, 221 consecutive patients underwent Pd-103 brachytherapy without androgen deprivation for clinically localized prostate cancer. Prebrachytherapy prostate-specific antigen (PSA) and serum testosterone were obtained for each patient. Repeat levels were obtained 3 months after brachytherapy and at least every 6 months thereafter. Multiple clinical, treatment, and dosimetric parameters were evaluated to determine an association with temporal testosterone changes. In addition, analysis was conducted to determine if there was an association between testosterone changes and treatment outcomes or the occurrence of a PSA spike. Results: There was no significant difference in serum testosterone over time after implant (p = 0.57). 29% of men experienced an increase {>=}25%, 23% of men experienced a decrease {>=}25%, and the remaining 48% of men had no notable change in testosterone over time. There was no difference in testosterone trends between men who received external beam radiotherapy and those who did not (p = 0.12). On multivariate analysis, preimplant testosterone was the only variable that consistently predicted for changes in testosterone over time. Men with higher than average testosterone tended to experience drop in testosterone (p < 0.001), whereas men with average or below average baseline testosterone had no significant change. There was no association between men who experienced PSA spike and testosterone temporal trends (p = 0.50) nor between initial PSA response and testosterone trends (p = 0.21). Conclusion: Prostate brachytherapy does not appear to impact serum testosterone over time. Changes in serum testosterone do not appear to be associated with PSA spike phenomena nor with initial PSA response to treatment; therefore, PSA response

  4. Manual on brachytherapy. Incorporating: Applications guide, procedures guide, basics guide

    International Nuclear Information System (INIS)

    1996-01-01

    This publication is part of practical radiation safety manual series for different fields of application aimed primarily at persons handling radiation sources on a daily routine basis, which could at same time be used by the competent authorities, supporting their efforts in the radiation protection training of workers or medical assistance personnel or helping on-site management to set up local radiation protection rules. It is dedicated to brachytherapy: its application and procedures guides

  5. HDR brachytherapy for superficial non-melanoma skin cancers

    International Nuclear Information System (INIS)

    Gauden, Ruth; Pracy, Martin; Avery, Anne-Marie; Hodgetts, Ian; Gauden, Stan

    2013-01-01

    Our initial experience using recommended high dose per fraction skin brachytherapy (BT) treatment schedules, resulted in poor cosmesis. This study aimed to assess in a prospective group of patients the use of Leipzig surface applicators for High Dose Rate (HDR) brachytherapy, for the treatment of small non-melanoma skin cancers (NMSC) using a protracted treatment schedule. Treatment was delivered by HDR brachytherapy with Leipzig applicators. 36Gy, prescribed to between 3 to 4mm, was given in daily 3Gy fractions. Acute skin toxicity was evaluated weekly during irradiation using the Radiation Therapy Oncology Group criteria. Local response, late skin effects and cosmetic results were monitored at periodic intervals after treatment completion. From March 2002, 200 patients with 236 lesions were treated. Median follow-up was 66 months (range 25–121 months). A total of 162 lesions were macroscopic, while in 74 cases, BT was given after resection because of positive microscopic margins. There were 121 lesions that were basal cell carcinomas, and 115 were squamous cell carcinomas. Lesions were located on the head and neck (198), the extremities (26) and trunk (12). Local control was 232/236 (98%). Four patients required further surgery to treat recurrence. Grade 1 acute skin toxicity was detected in 168 treated lesions (71%) and grade 2 in 81 (34%). Cosmesis was good or excellent in 208 cases (88%). Late skin hypopigmentation changes were observed in 13 cases (5.5%). Delivering 36Gy over 2 weeks to superficial NMSC using HDR brachytherapy is well tolerated and provides a high local control rate without significant toxicity.

  6. Primary calibration of coiled 103Pd brachytherapy sources

    International Nuclear Information System (INIS)

    Paxton, Adam B.; Culberson, Wesley S.; DeWerd, Larry A.; Micka, John A.

    2008-01-01

    Coiled 103 Pd brachytherapy sources have been developed by RadioMed Corporation for use as low-dose-rate (LDR) interstitial implants. The coiled sources are provided in integer lengths from 1 to 6 cm and address many common issues seen with traditional LDR brachytherapy sources. The current standard for determining the air-kerma strength (S K ) of low-energy LDR brachytherapy sources is the National Institute of Standards and Technology's Wide-Angle Free-Air Chamber (NIST WAFAC). Due to geometric limitations, however, the NIST WAFAC is unable to determine the S K of sources longer than 1 cm. This project utilized the University of Wisconsin's Variable-Aperture Free-Air Chamber (UW VAFAC) to determine the S K of the longer coiled sources. The UW VAFAC has shown agreement in S K values of 1 cm length coils to within 1% of those determined with the NIST WAFAC, but the UW VAFAC does not share the same geometric limitations as the NIST WAFAC. A new source holder was constructed to hold the coiled sources in place during measurements with the UW VAFAC. Correction factors for the increased length of the sources have been determined and applied to the measurements. Using the new source holder and corrections, the S K of 3 and 6 cm coiled sources has been determined. Corrected UW VAFAC data and ionization current measurements from well chambers have been used to determine calibration coefficients for use in the measurement of 3 and 6 cm coiled sources in well chambers. Thus, the UW VAFAC has provided the first transferable, primary measurement of low-energy LDR brachytherapy sources with lengths greater than 1 cm

  7. Ocular brachytherapy with a holmium-166 irradiator device

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.; Campos, Tarcisio P.R.

    2009-01-01

    The ocular brachytherapy is a method that allows controlling ocular tumors. However, the irradiation of the ocular area in high doses can bring damages mainly to the surrounding healthy tissue, such as lens, retina and bone tissue of the orbital area in growth phase. Brachytherapy in comparison to teletherapy allows a large reduction of the absorbed doses in the adjacent tissues avoiding deleterious effects. Various types of radionuclides can be applied to ocular brachytherapy. Those radionuclides shall be encapsulated and placed juxtaposed to the sclera, back to the tumor. Herein, a new device was developed to encapsulate the radioactive material. It can easily place back of the eyeball. A computational model of the ocular area was developed in order to simulate the spatial dose distribution promoted by the holmium-166 nuclide distributed inside the irradiator device. The simulations addressed a device placed on the surface of the sclera, rotated 90 deg taken at the normal axis forward to the lens. The simulation was carried on the code Monte Carlo MCNP5. The computational simulation generates the spatial dose distribution in the treated volume. All continuous beta and the discrete gamma and X-ray spectra emitted by the holmium-166 were incorporated on simulations. The results allow comparing the space dose distribution to other types of sources used for the same end. The sclera absorbed dose, the maximum apical tumor dose, as well as on the tumor base were investigated. Indeed, the tumor thickness defines the conditions of irradiation. The holmium-166 dose distribution provides a tool to propose a better and optimized protocol for ocular brachytherapy. (author)

  8. Proposals for common definitions of reference points in gynecological brachytherapy

    International Nuclear Information System (INIS)

    Chassagne, D.; Horiot, J.C.

    1977-01-01

    In May 1975 the report of European Curietherapy Group recommended in gynecological Dosimetry by computer. Use of reference points = lymphatic trapezoid figure with 6 points, Pelvic wall, all points are refering to bony structures. Use of critical organ reference points = maximum rectum dose, bladder dose mean rectal dose. Use of 6,000 rads reference isodose described by height, width, and thickness dimensions. These proposals are the basis of a common language in gynecological brachytherapy [fr

  9. The status of low dose rate and future of high dose rate Cf-252 brachytherapy

    International Nuclear Information System (INIS)

    Rivard, M.J.; Wierzbicki, J.G.; Van den Heuvel, F.; Chuba, P.J.; Fontanesi, J.

    1997-12-01

    This work describes the current status of the US low dose rate (LDR) Cf-252 brachytherapy program. The efforts undertaken towards development of a high dose rate (HDR) remotely after loaded Cf-252 source, which can accommodate 1 mg or greater Cf-252, are also described. This HDR effort is a collaboration between Oak Ridge National Laboratory (ORNL), commercial remote after loader manufactures, the Gershenson Radiation Oncology Center (ROC), and Wayne State University. To achieve this goal, several advances in isotope chemistry and source preparation at ORNL must be achieved to yield a specific material source loading of greater than or equal 1 mg Cf-252 per mm3. Development work with both radioactive and non-radioactive stand-ins for Cf-252 have indicated the feasibility of fabricating such sources. As a result, the decreased catheter diameter and computer controlled source placement will permit additional sites (e.g. brain, breast, prostate, lung, parotid, etc.) to be treated effectively with Cf-252 sources. Additional work at the Radiochemical Engineering and Development Center (REDC) remains in source fabrication, after loader modification, and safe design. The current LDR Cf-252 Treatment Suite at the ROC is shielded and licensed to hold up to 1 mg of Cf-252. This was designed to maintain cumulative personnel exposure, both external to the room and in direct isotope handling, at less than 20 microSv/hr. However, cumulative exposure may be greatly decreased if a Cf-252 HDR unit is employed which would eliminate direct isotope handling and decrease treatment times from tilde 3 hours to an expected range of 3 to 15 minutes. Such a Cf-252 HDR source will also demonstrate improved dose distributions over current LDR treatments due to the ability to step the point-like source throughout the target volume and weight the dwell time accordingly

  10. Visual acuity after Ruthenium106 brachytherapy of choroidal melanomas

    International Nuclear Information System (INIS)

    Damato, Bertil; Patel, Imran M.; Campbell, Ian R.; Mayles, Helen M.; Errington, R. Douglas

    2005-01-01

    Purpose: To report on conservation of visual acuity after Ruthenium 106 (Ru-106) brachytherapy of choroidal melanoma. Methods and materials: This study was a noncomparative interventional case series of 458 patients with choroidal melanoma treated at a single center between January 1993 and December 2001. The intervention consisted of Ru-106 brachytherapy delivering minimum scleral and apex doses of 300 Gy and 80 Gy, respectively, using a 15-mm or 20-mm plaque. For discrete, posterior tumors, the plaque was positioned eccentrically with its posterior edge aligned with the posterior tumor margin. To ensure correct plaque positioning, any overlying extraocular muscles were dis-inserted, and the locations of both tumor and plaque edges were confirmed by transillumination and indentation. The main outcome measures were conservation of vision of 20/40 or better, 20/200 or better, and Counting Fingers or better, according to baseline variables. Results: The actuarial rate of conservation of 20/40 or better was 55% at 9 years, loss of such vision correlating with posterior tumor extension (p 106 brachytherapy of posterior choroidal melanoma achieves good conservation of vision if the tumor does not extend close to the optic nerve or fovea

  11. Invited review, recent developments in brachytherapy source dosimetry

    International Nuclear Information System (INIS)

    Meigooni, A.S.

    2004-01-01

    Application of radioactive isotopes is the treatment of choice around the globe for many cancer sites. In this technique, the accuracy of the radiation delivery is highly dependent on the accuracy of radiation dosimetry around individual brachytherapy sources. Moreover, in order to have compatible clinical results, an identical method of source dosimetry must be employed across the world. This problem has been recently addressed by task group 43 from the American Association of Medical Physics with a protocol for dosimetric characterization of brachytherapy sources. This new protocol has been further updated using published data from international sources, by a new Task Group from the American Association of Medical Physics. This has resulted in an updated protocol known as TG43U1 that has been published in March 2004 issue of Medical Physics. The goal of this presentation is to review the original Task Group 43 protocol and associated algorithms for brachytherapy source dosimetry. In addition, the shortcomings of the original protocol that has been resolved in the updated recommendation will be highlighted. I am sure that this is not the end of the line and more work is needed to complete this task. I invite the scientists to join this task and complete the project, with the hope of much better clinical results for cancer patients

  12. Brachytherapy for treatment of cervix cancer in Madagascar

    International Nuclear Information System (INIS)

    Pignon, T.; Ratovonarivo, H.; Rafaramino, F.; Ruggieri, S.

    1993-01-01

    From March 1986 to June 1988, 60 patients with carcinoma of the uterine cervix were treated by radiotherapy alone or combined radiotherapy and surgery at the only radiotherapy-oncology department of Madagascar in Antananarivo. There were 20 stage IB, 28 stage II, 5 stage III and 7 cases where initial stage before surgery was unknown. After a limited pre-therapeutic investigation, treatment for stage IB consisted of utero-vaginal brachytherapy followed by a colpo-hysterectomy and external iliac lymphadenectomy. Others received combined external radiotherapy and brachytherapy according to the Fletcher guidelines, although 30 patients also received surgery. An obsolete and inefficient cobalt unit with lack of computerized dosimetry made the management of therapeutic schemas difficult. Nineteen patients (31.6%) were not available for follow-up immediately after the end of the treatment and one patient died from intestinal occlusion during brachytherapy. The overall rate of severe complications was 4.8%. There were 12 recurrences which occurred in stage II or in patients with unknown initial staging. At the time of analysis, 25 patients were alive: 15 stage I and 10 stage II. In this country, cervical carcinomas are the most frequent tumors: only the rehabilitation of radiotherapy facilities will allow results to be improved

  13. Patterns of care for brachytherapy in Europe: Updated results

    International Nuclear Information System (INIS)

    Guedea, Ferran; Venselaar, Jack; Hoskin, Peter; Hellebust, Taran Paulsen; Peiffert, Didier; Londres, Bradley; Ventura, Montse; Mazeron, Jean-Jacques; Van Limbergen, Erik; Poetter, Richard; Kovacs, Gyorgy

    2010-01-01

    Objective: This descriptive survey evaluated brachytherapy (BT) practices and resources in the European area. This was a follow-up study to the original patterns of care for brachytherapy in Europe (PCBE). Materials and methods: A total of 1121 radiotherapy (RT) centres from 41 countries were asked to complete an online questionnaire on BT practices and resources. Countries with fewer than 50% of centres responding were excluded. Participating countries were divided into three groups based on gross domestic product (GDP); group I contained the countries with the highest GDP. Results: The response rate was 56% (633/1121 centres) with 30/41 countries (73%) meeting the inclusion criteria. Sixty percent of reporting centres provided brachytherapy. Responding centres treated an average of 138 (±10, 1 SD) patients with BT; in group I, the mean was 110/centre, an increase of 18% from 2002. CT-dosimetry increased to 61% of centres vs. 33% in 2002. HDR (high-dose rate) BT was the most commonly reported technique (65% of centres). Most BT interventions were for gynaecological tumors (59% of all cases), followed by prostate (17%), breast (9%), lung/bronchus (3%), and esophagus tumors(2%). Conclusion: Gynaecological BT remains the most common application, although both prostate and breast BT have increased. CT-based dosimetry has become increasingly common since 2002. The use of HDR and PDR (pulsed-dose rate) techniques has increased markedly, while both LDR and MDR (medium-dose rate) have declined.

  14. Implication for QOL after I-125 brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Teishima, Jun; Yasumoto, Hiroaki; Inoue, Syogo; Masumoto, Hiroshi; Hasegawa, Yasuhisa; Matsubara, Akio

    2009-01-01

    The aim of this study is to evaluate the quality of life (QOL) of patients following prostate brachytherapy. Between July 2004 and May 2008, 139 patients underwent I-125 permanent brachytherapy. Among those patients, 69 who were followed up for more than one year using the Expanded Prostate Index Composite (EPIC), Japanese version v1 TM , were enrolled in this study. Urinary summary scores became worse temporarily at 1 month after the end of treatment, but then recovered gradually to the level before treatment. Sexual summary scores before treatment were 42.2±16.3. They became worse temporarily at 1 month after treatment but then recovered gradually in patients whose sexual summary scores were more than 40. Urinary morbidity scores after prostate brachytherapy were not so severe and recovered within a short period. Further long-term observation is thought to be required in the future. Sexual function scores of patients before treatment in the present study were lower compared with those recorded in previous studies. (author)

  15. Audits in high dose rate brachytherapy in Brazil

    International Nuclear Information System (INIS)

    Marechal, M.H.; Rosa, L.A.; Velasco, A.; Paiva, E. de; Goncalves, M.; Castelo, L.C.

    2002-01-01

    The lack of well established dosimetry protocols for HDR sources is a point of great concern regarding the uniformity of procedures within a particular country. The main objective of this paper is to report the results of an implementation of the audit program in dosimetry of high dose rate brachytherapy sources used by the radiation therapy centers in Brazil. In Brazil, among 169 radiotherapy centers, 35 have HDR brachytherapy systems. This program started in August 2001 and until now eight radiotherapy services were audited. The audit program consists of the visit in loco to each center and the evaluation of the intensity of the source with a well type chamber specially design for HDR 192 Ir sources. The measurements was carried out with a HDR1000PLUS Brachytherapy Well Type Chamber and a MAX 4000 Electrometer, both manufactured by Standard Imaging Inc. The chamber was calibrated in air kerma strength by the Accredited Dosimetry Calibration Laboratory, Department of Medical Physics, University of Wisconsin in the USA. The same chamber was calibrated in Brazil using a 192 lr high dose rate source whose intensity was determined by 60 Co gamma rays and 250 kV x rays interpolation methodology. The Nk of 60 Co and 250 kV x rays were provided by the Brazilian National Standard Laboratory for Ionizing Radiation (LMNRI)

  16. Does immediate postoperative brachytherapy allow to broaden the indications of conservative treatment in breast cancer?

    International Nuclear Information System (INIS)

    Floiras, J.L.

    1998-01-01

    A 1997 study of long-term outcomes in 109 patients with unilateral stage I or II breast cancer treated by brachytherapy between 1983 and 1985 found significantly lower recurrence rates than in a conservatively-treated group of patients managed at the same institution. The benefits of brachytherapy, of a booster dose after after surgery, and of adjuvant medical therapy are emphasized. (author)

  17. American Brachytherapy Society Task Group Report: Combination of brachytherapy and external beam radiation for high-risk prostate cancer.

    Science.gov (United States)

    Spratt, Daniel E; Soni, Payal D; McLaughlin, Patrick W; Merrick, Gregory S; Stock, Richard G; Blasko, John C; Zelefsky, Michael J

    To review outcomes for high-risk prostate cancer treated with combined modality radiation therapy (CMRT) utilizing external beam radiation therapy (EBRT) with a brachytherapy boost. The available literature for high-risk prostate cancer treated with combined modality radiation therapy was reviewed and summarized. At this time, the literature suggests that the majority of high-risk cancers are curable with multimodal treatment. Several large retrospective studies and three prospective randomized trials comparing CMRT to dose-escalated EBRT have demonstrated superior biochemical control with CMRT. Longer followup of the randomized trials will be required to determine if this will translate to a benefit in metastasis-free survival, disease-specific survival, and overall survival. Although greater toxicity has been associated with CMRT compared to EBRT, recent studies suggest that technological advances that allow better definition and sparing of critical adjacent structures as well as increasing experience with brachytherapy have improved implant quality and the toxicity profile of brachytherapy. The role of androgen deprivation therapy is well established in the external beam literature for high-risk disease, but there is controversy regarding the applicability of these data in the setting of dose escalation. At this time, there is not sufficient evidence for the omission of androgen deprivation therapy with dose escalation in this population. Comparisons with surgery remain limited by differences in patient selection, but the evidence would suggest better disease control with CMRT compared to surgery alone. Due to a series of technological advances, modern combination series have demonstrated unparalleled rates of disease control in the high-risk population. Given the evidence from recent randomized trials, combination therapy may become the standard of care for high-risk cancers. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All

  18. Contemporary Toxicity Profile of Breast Brachytherapy Versus External Beam Radiation After Lumpectomy for Breast Cancer

    International Nuclear Information System (INIS)

    Huo, Jinhai; Giordano, Sharon H.; Smith, Benjamin D.; Shaitelman, Simona F.; Smith, Grace L.

    2016-01-01

    Purpose: We compared toxicities after brachytherapy versus external beam radiation therapy (EBRT) in contemporary breast cancer patients. Methods and Materials: Using MarketScan healthcare claims, we identified 64,112 women treated from 2003 to 2012 with lumpectomy followed by radiation (brachytherapy vs EBRT). Brachytherapy was