WorldWideScience

Sample records for reliable survey instrument

  1. Identifying the Barriers to Using Games and Simulations in Education: Creating a Valid and Reliable Survey Instrument

    Science.gov (United States)

    Justice, Lenora Jean

    2012-01-01

    The purpose of this study was to create a valid and reliable instrument to measure teacher perceived barriers to the adoption of games and simulations in instruction. Previous research, interviews with educators, a focus group, an expert review, and a think aloud protocol were used to design a survey instrument. After finalization, the survey was…

  2. Reliability and Validity of Survey Instruments to Measure Work-Related Fatigue in the Emergency Medical Services Setting: A Systematic Review

    Science.gov (United States)

    2018-01-11

    Background: This study sought to systematically search the literature to identify reliable and valid survey instruments for fatigue measurement in the Emergency Medical Services (EMS) occupational setting. Methods: A systematic review study design wa...

  3. Reliability and Validity of Survey Instruments to Measure Work-Related Fatigue in the Emergency Medical Services Setting: A Systematic Review.

    Science.gov (United States)

    Patterson, P Daniel; Weaver, Matthew D; Fabio, Anthony; Teasley, Ellen M; Renn, Megan L; Curtis, Brett R; Matthews, Margaret E; Kroemer, Andrew J; Xun, Xiaoshuang; Bizhanova, Zhadyra; Weiss, Patricia M; Sequeira, Denisse J; Coppler, Patrick J; Lang, Eddy S; Higgins, J Stephen

    2018-02-15

    This study sought to systematically search the literature to identify reliable and valid survey instruments for fatigue measurement in the Emergency Medical Services (EMS) occupational setting. A systematic review study design was used and searched six databases, including one website. The research question guiding the search was developed a priori and registered with the PROSPERO database of systematic reviews: "Are there reliable and valid instruments for measuring fatigue among EMS personnel?" (2016:CRD42016040097). The primary outcome of interest was criterion-related validity. Important outcomes of interest included reliability (e.g., internal consistency), and indicators of sensitivity and specificity. Members of the research team independently screened records from the databases. Full-text articles were evaluated by adapting the Bolster and Rourke system for categorizing findings of systematic reviews, and the rated data abstracted from the body of literature as favorable, unfavorable, mixed/inconclusive, or no impact. The Grading of Recommendations, Assessment, Development and Evaluation (GRADE) methodology was used to evaluate the quality of evidence. The search strategy yielded 1,257 unique records. Thirty-four unique experimental and non-experimental studies were determined relevant following full-text review. Nineteen studies reported on the reliability and/or validity of ten different fatigue survey instruments. Eighteen different studies evaluated the reliability and/or validity of four different sleepiness survey instruments. None of the retained studies reported sensitivity or specificity. Evidence quality was rated as very low across all outcomes. In this systematic review, limited evidence of the reliability and validity of 14 different survey instruments to assess the fatigue and/or sleepiness status of EMS personnel and related shift worker groups was identified.

  4. A survey on the high reliability software verification and validation technology for instrumentation and control in NPP.

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Lee, Chang Soo; Dong, In Sook [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-01-01

    This document presents the technical status of the software verification and validation (V and V) efforts to support developing and licensing digital instrumentation and control (I and C) systems in nuclear power plants. We have reviewed codes and standards to be concensus criteria among vendor, licensee and licenser. Then we have described the software licensing procedures under 10 CFR 50 and 10 CFR 52 of the United States cope with the licensing barrier. At last, we have surveyed the technical issues related to developing and licensing the high integrity software for digital I and C systems. These technical issues let us know the development direction of our own software V and V methodology. (Author) 13 refs., 2 figs.,.

  5. Operational and reliability experience with reactor instrumentation

    International Nuclear Information System (INIS)

    Dixon, F.; Gow, R.S.

    1978-01-01

    In the last 15 years the CEGB has experienced progressive plant development, integration and changes in operating regime through nine nuclear (gas-cooled reactor) power stations with corresponding instrumentation advances leading towards more refined centralized control. Operation and reliability experience with reactor instrumentation is reported in this paper with reference to the progressive changes related to the early magnox, late magnox and AGR periods. Data on instrumentation reliability in terms of reactor forced outages are presented and show that the instrumentation contributions to loss of generating plant availability are small. Reactor safety circuits, neutron flux and temperature measurements, gas analysis and vibration monitoring are discussed. In reviewing the reactor instrumentation the emphasis is on reporting recent experience, particularly on AGR equipment, but overall performance and changes to magnox equipment are included so that some appreciation can be obtained of instrumentation requirements with respect to plant lifetimes. (author)

  6. Reliability of visual and instrumental color matching.

    Science.gov (United States)

    Igiel, Christopher; Lehmann, Karl Martin; Ghinea, Razvan; Weyhrauch, Michael; Hangx, Ysbrand; Scheller, Herbert; Paravina, Rade D

    2017-09-01

    The aim of this investigation was to evaluate intra-rater and inter-rater reliability of visual and instrumental shade matching. Forty individuals with normal color perception participated in this study. The right maxillary central incisor of a teaching model was prepared and restored with 10 feldspathic all-ceramic crowns of different shades. A shade matching session consisted of the observer (rater) visually selecting the best match by using VITA classical A1-D4 (VC) and VITA Toothguide 3D Master (3D) shade guides and the VITA Easyshade Advance intraoral spectrophotometer (ES) to obtain both VC and 3D matches. Three shade matching sessions were held with 4 to 6 weeks between sessions. Intra-rater reliability was assessed based on the percentage of agreement for the three sessions for the same observer, whereas the inter-rater reliability was calculated as mean percentage of agreement between different observers. The Fleiss' Kappa statistical analysis was used to evaluate visual inter-rater reliability. The mean intra-rater reliability for the visual shade selection was 64(11) for VC and 48(10) for 3D. The corresponding ES values were 96(4) for both VC and 3D. The percentages of observers who matched the same shade with VC and 3D were 55(10) and 43(12), respectively, while corresponding ES values were 88(8) for VC and 92(4) for 3D. The results for visual shade matching exhibited a high to moderate level of inconsistency for both intra-rater and inter-rater comparisons. The VITA Easyshade Advance intraoral spectrophotometer exhibited significantly better reliability compared with visual shade selection. This study evaluates the ability of observers to consistently match the same shade visually and with a dental spectrophotometer in different sessions. The intra-rater and inter-rater reliability (agreement of repeated shade matching) of visual and instrumental tooth color matching strongly suggest the use of color matching instruments as a supplementary tool in

  7. Digital readout alpha survey instrument

    International Nuclear Information System (INIS)

    Jacobs, M.E.

    1976-01-01

    A prototype solid-state digital readout alpha particle survey instrument has been designed and constructed. The meter incorporates a Ludlum alpha scintillator as a detector, digital logic circuits for control and timing, and a Digilin counting module with reflective liquid crystal display. The device is used to monitor alpha radiation from a surface. Sample counts are totalized over 10-second intervals and displayed digitally in counts per minute up to 19,999. Tests over source samples with counts to 15,600 cpm have shown the device to be rapid, versatile and accurate. The instrument can be fabricated in one man-week and requires about $835 in material costs. A complete set of drawings is included

  8. A Survey of Network Reliability.

    Science.gov (United States)

    1983-07-01

    STATEMENT A. Atoyed for public releosel Oo . Distibution Unlimited JULY 1983 ORC 83-5 This research was supported by the Air Force Office of Scientific ...cONTso.oSoo oaoCC NaME ara AOoM It. REPORT DATE United States Air Force July 1983 Air Force Office of Scientific Research IL NUNeen or s Boiling Air Force Base...One node in K is designated the root and the reliability problem is to calculate the probability that the root can comunicate with the remaining K C V

  9. Survey of instruments for micrometeorology

    National Research Council Canada - National Science Library

    Monteith, John Lennox

    1972-01-01

    ... have been developed for micrometeorological measurements. Many of these instruments can be used by ecologists to measure and define the environment of plants and animals and to explore the ways in which organisms modify the environment they are exposed...

  10. An Attitude Scale on Individual Instrument and Individual Instrument Course: Validity-Reliability Research

    Science.gov (United States)

    Kuçukosmanoglu, Hayrettin Onur

    2015-01-01

    The main purpose of this study is to develop a scale to determine students' attitude levels on individual instruments and individual instrument courses in instrument training, which is an important dimension of music education, and to conduct a validity-reliability research of the scale that has been developed. The scale consists of 16 items. The…

  11. The contribution of instrumentation and control software to system reliability

    International Nuclear Information System (INIS)

    Fryer, M.O.

    1984-01-01

    Advanced instrumentation and control systems are usually implemented using computers that monitor the instrumentation and issue commands to control elements. The control commands are based on instrument readings and software control logic. The reliability of the total system will be affected by the software design. When comparing software designs, an evaluation of how each design can contribute to the reliability of the system is desirable. Unfortunately, the science of reliability assessment of combined hardware and software systems is in its infancy. Reliability assessment of combined hardware/software systems is often based on over-simplified assumptions about software behavior. A new method of reliability assessment of combined software/hardware systems is presented. The method is based on a procedure called fault tree analysis which determines how component failures can contribute to system failure. Fault tree analysis is a well developed method for reliability assessment of hardware systems and produces quantitative estimates of failure probability based on component failure rates. It is shown how software control logic can be mapped into a fault tree that depicts both software and hardware contributions to system failure. The new method is important because it provides a way for quantitatively evaluating the reliability contribution of software designs. In many applications, this can help guide designers in producing safer and more reliable systems. An application to the nuclear power research industry is discussed

  12. Reliability Estimation for Digital Instrument/Control System

    International Nuclear Information System (INIS)

    Yang, Yaguang; Sydnor, Russell

    2011-01-01

    Digital instrumentation and controls (DI and C) systems are widely adopted in various industries because of their flexibility and ability to implement various functions that can be used to automatically monitor, analyze, and control complicated systems. It is anticipated that the DI and C will replace the traditional analog instrumentation and controls (AI and C) systems in all future nuclear reactor designs. There is an increasing interest for reliability and risk analyses for safety critical DI and C systems in regulatory organizations, such as The United States Nuclear Regulatory Commission. Developing reliability models and reliability estimation methods for digital reactor control and protection systems will involve every part of the DI and C system, such as sensors, signal conditioning and processing components, transmission lines and digital communication systems, D/A and A/D converters, computer system, signal processing software, control and protection software, power supply system, and actuators. Some of these components are hardware, such as sensors and actuators, their failure mechanisms are well understood, and the traditional reliability model and estimation methods can be directly applied. But many of these components are firmware which has software embedded in the hardware, and software needs special consideration because its failure mechanism is unique, and the reliability estimation method for a software system will be different from the ones used for hardware systems. In this paper, we will propose a reliability estimation method for the entire DI and C system reliability using a recently developed software reliability estimation method and a traditional hardware reliability estimation method

  13. Reliability Estimation for Digital Instrument/Control System

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yaguang; Sydnor, Russell [U.S. Nuclear Regulatory Commission, Washington, D.C. (United States)

    2011-08-15

    Digital instrumentation and controls (DI and C) systems are widely adopted in various industries because of their flexibility and ability to implement various functions that can be used to automatically monitor, analyze, and control complicated systems. It is anticipated that the DI and C will replace the traditional analog instrumentation and controls (AI and C) systems in all future nuclear reactor designs. There is an increasing interest for reliability and risk analyses for safety critical DI and C systems in regulatory organizations, such as The United States Nuclear Regulatory Commission. Developing reliability models and reliability estimation methods for digital reactor control and protection systems will involve every part of the DI and C system, such as sensors, signal conditioning and processing components, transmission lines and digital communication systems, D/A and A/D converters, computer system, signal processing software, control and protection software, power supply system, and actuators. Some of these components are hardware, such as sensors and actuators, their failure mechanisms are well understood, and the traditional reliability model and estimation methods can be directly applied. But many of these components are firmware which has software embedded in the hardware, and software needs special consideration because its failure mechanism is unique, and the reliability estimation method for a software system will be different from the ones used for hardware systems. In this paper, we will propose a reliability estimation method for the entire DI and C system reliability using a recently developed software reliability estimation method and a traditional hardware reliability estimation method.

  14. Survey of beam instrumentation used in SLC

    International Nuclear Information System (INIS)

    Ecklund, S.D.

    1991-03-01

    A survey of beam instruments used at SLAC in the SLC machine is presented. The basic utility and operation of each device is briefly described. The various beam instruments used at the Stanford Linear Collider (SLC), can be classified by the function they perform. Beam intensity, position and size are typical of the parameters of beam which are measured. Each type of parameter is important for adjusting or tuning the machine in order to achieve optimum performance. 39 refs

  15. The Trojan Lifetime Champions Health Survey: Development, Validity, and Reliability

    Science.gov (United States)

    Sorenson, Shawn C.; Romano, Russell; Scholefield, Robin M.; Schroeder, E. Todd; Azen, Stanley P.; Salem, George J.

    2015-01-01

    Context Self-report questionnaires are an important method of evaluating lifespan health, exercise, and health-related quality of life (HRQL) outcomes among elite, competitive athletes. Few instruments, however, have undergone formal characterization of their psychometric properties within this population. Objective To evaluate the validity and reliability of a novel health and exercise questionnaire, the Trojan Lifetime Champions (TLC) Health Survey. Design Descriptive laboratory study. Setting A large National Collegiate Athletic Association Division I university. Patients or Other Participants A total of 63 university alumni (age range, 24 to 84 years), including former varsity collegiate athletes and a control group of nonathletes. Intervention(s) Participants completed the TLC Health Survey twice at a mean interval of 23 days with randomization to the paper or electronic version of the instrument. Main Outcome Measure(s) Content validity, feasibility of administration, test-retest reliability, parallel-form reliability between paper and electronic forms, and estimates of systematic and typical error versus differences of clinical interest were assessed across a broad range of health, exercise, and HRQL measures. Results Correlation coefficients, including intraclass correlation coefficients (ICCs) for continuous variables and κ agreement statistics for ordinal variables, for test-retest reliability averaged 0.86, 0.90, 0.80, and 0.74 for HRQL, lifetime health, recent health, and exercise variables, respectively. Correlation coefficients, again ICCs and κ, for parallel-form reliability (ie, equivalence) between paper and electronic versions averaged 0.90, 0.85, 0.85, and 0.81 for HRQL, lifetime health, recent health, and exercise variables, respectively. Typical measurement error was less than the a priori thresholds of clinical interest, and we found minimal evidence of systematic test-retest error. We found strong evidence of content validity, convergent

  16. RICE: A Reliable and Efficient Remote Instrumentation Collaboration Environment

    Directory of Open Access Journals (Sweden)

    Prasad Calyam

    2008-01-01

    Full Text Available Remote access of scientific instruments over the Internet (i.e., remote instrumentation demand high-resolution (2D and 3D video image transfers with simultaneous real-time mouse and keyboard controls. Consequently, user quality of experience (QoE is highly sensitive to network bottlenecks. Further, improper user control while reacting to impaired video caused due to network bottlenecks could result in physical damages to the expensive instrument equipment. Hence, it is vital to understand the interplay between (a user keyboard/mouse actions toward the instrument, and (b corresponding network reactions for transfer of instrument video images toward the user. In this paper, we first present an analytical model for characterizing user and network interplay during remote instrumentation sessions in terms of demand and supply interplay principles of traditional economics. Next, we describe the trends of the model parameters using subjective and objective measurements obtained from QoE experiments. Thereafter, we describe our Remote Instrumentation Collaboration Environment (RICE software that leverages our experiences from the user and network interplay studies, and has functionalities that facilitate reliable and efficient remote instrumentation such as (a network health awareness to detect network bottleneck periods, and (b collaboration tools for multiple participants to interact during research and training sessions.

  17. Investigation of four self-report instruments (FABT, TSK-HC, Back-PAQ, HC-PAIRS) to measure healthcare practitioners' attitudes and beliefs toward low back pain: Reliability, convergent validity and survey of New Zealand osteopaths and manipulative physiotherapists.

    Science.gov (United States)

    Moran, Robert W; Rushworth, Wendy M; Mason, Jesse

    2017-12-01

    Healthcare practitioner beliefs influence advice and management provided to patients with back pain. Several instruments measuring practitioner beliefs have been developed but psychometric properties for some have not been investigated. To investigate internal consistency, test-retest reliability and convergent validity of the Fear Avoidance Beliefs Tool (FABT), the Tampa Scale of Kinesiophobia for Health Care Providers (TSK-HC), the Back Pain Attitudes Questionnaire (Back-PAQ), and the Health Care Pain and Impairment Relationship Scale (HC-PAIRS). A secondary aim was to explore beliefs of New Zealand osteopaths and physiotherapists regarding low back pain. FABT, TSK-HC, Back-PAQ, and HC-PAIRS were administered twice, 14 days apart. Data from 91 osteopaths and 35 physiotherapists were analysed. The FABT, TSK-HC and Back-PAQ each demonstrated excellent internal consistency, (Cronbach's α = 0.92, 0.91, and 0.91 respectively), and excellent test-retest reliability (lower limit of 95% CI for intraclass correlation coefficient >0.75). Correlations between instruments (Pearson's r = 0.51 to 0.77, p  0.47) for mean differences in scores, for all instruments, between professions. This study found excellent internal consistency, test-retest reliability and good convergent validity for the FABT, TSK-HC, and Back-PAQ. Previously reported internal consistency, test-retest and convergent validity of the HC-PAIRS were confirmed, and test-retest reliability was excellent. There were significant scoring differences on each instrument between professions, and while both groups demonstrated fear avoidant beliefs, physiotherapist respondent scores indicated that as a group, they held fewer fear-avoidant beliefs than osteopath respondents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Survey of industry methods for producing highly reliable software

    International Nuclear Information System (INIS)

    Lawrence, J.D.; Persons, W.L.

    1994-11-01

    The Nuclear Reactor Regulation Office of the US Nuclear Regulatory Commission is charged with assessing the safety of new instrument and control designs for nuclear power plants which may use computer-based reactor protection systems. Lawrence Livermore National Laboratory has evaluated the latest techniques in software reliability for measurement, estimation, error detection, and prediction that can be used during the software life cycle as a means of risk assessment for reactor protection systems. One aspect of this task has been a survey of the software industry to collect information to help identify the design factors used to improve the reliability and safety of software. The intent was to discover what practices really work in industry and what design factors are used by industry to achieve highly reliable software. The results of the survey are documented in this report. Three companies participated in the survey: Computer Sciences Corporation, International Business Machines (Federal Systems Company), and TRW. Discussions were also held with NASA Software Engineering Lab/University of Maryland/CSC, and the AIAA Software Reliability Project

  19. Validity evidence and reliability of a simulated patient feedback instrument.

    Science.gov (United States)

    Schlegel, Claudia; Woermann, Ulrich; Rethans, Jan-Joost; van der Vleuten, Cees

    2012-01-27

    In the training of healthcare professionals, one of the advantages of communication training with simulated patients (SPs) is the SP's ability to provide direct feedback to students after a simulated clinical encounter. The quality of SP feedback must be monitored, especially because it is well known that feedback can have a profound effect on student performance. Due to the current lack of valid and reliable instruments to assess the quality of SP feedback, our study examined the validity and reliability of one potential instrument, the 'modified Quality of Simulated Patient Feedback Form' (mQSF). Content validity of the mQSF was assessed by inviting experts in the area of simulated clinical encounters to rate the importance of the mQSF items. Moreover, generalizability theory was used to examine the reliability of the mQSF. Our data came from videotapes of clinical encounters between six simulated patients and six students and the ensuing feedback from the SPs to the students. Ten faculty members judged the SP feedback according to the items on the mQSF. Three weeks later, this procedure was repeated with the same faculty members and recordings. All but two items of the mQSF received importance ratings of > 2.5 on a four-point rating scale. A generalizability coefficient of 0.77 was established with two judges observing one encounter. The findings for content validity and reliability with two judges suggest that the mQSF is a valid and reliable instrument to assess the quality of feedback provided by simulated patients.

  20. Test-Retest Reliability of a Survey to Measure Transport-Related Physical Activity in Adults

    Science.gov (United States)

    Badland, Hannah; Schofield, Grant

    2006-01-01

    The present research details test-retest reliability of a newly developed, telephone-administered TPA survey for adults. This instrument examines barriers, perceptions, and current travel behaviors to place of work/study and local convenience shops. Demonstrated test-retest reliability of the Active Friendly Environments-Transport-Related Physical…

  1. Regulatory requirements on the calibration and use of survey instruments

    International Nuclear Information System (INIS)

    Domondon, D.B.

    1989-01-01

    Regulatory requirements on the provision, calibration and occasions of use of survey instruments are enumerated for a number of licensed activities. Two methods of calibrating survey instruments are described. Factors that must be taken into consideration in conducting calibrations, contents of calibration reports and of the sticker attached to the instrument which are needed for the correct use of the instrument are discussed. The precautions to be observed in order to insure correct use of survey instruments are described. (Auth.)

  2. Practical implications of neutron survey instrument performance

    International Nuclear Information System (INIS)

    Tanner, R. J.; Bartlett, D. T.; Hager, I. G.; Jones, I. N.; Molinos, C.; Roberts, N. J.; Taylor, G. C.; Thomas, D. J.

    2004-01-01

    Improvements have been made to the Monte Carlo modelling used to calculate the response of the neutron survey instruments most commonly used in the UK, for neutron energies up to 20 MeV. The improved modelling of the devices includes the electronics and battery pack, allowing better calculations of both the energy and angle dependence of response. These data are used to calculate the response of the instruments in rotationally and fully isotropic, as well as unidirectional fields. Experimental measurements with radionuclide sources and monoenergetic neutron fields have been, and continue to be made, to test the calculated response characteristics. The enhancements to the calculations have involved simulation of the sensitivity of the response to variations in instrument manufacture, and will include the influence of the user and floor during measurements. The practical implications of the energy and angle dependence of response, variations in manufacture, and the influence of the user are assessed by folding the response characteristics with workplace energy and direction distributions. (authors)

  3. DEVELOPING OF INDIVIDUAL INSTRUMENT PERFORMANCE ANXIETY SCALE: VALIDITY - RELIABILITY STUDY

    Directory of Open Access Journals (Sweden)

    Esra DALKIRAN

    2014-07-01

    Full Text Available The purpose of this study is to develop a scale unique to our culture, concerning  individual instrument performance anxiety of the students  who are getting instrument training  in the Department of Music Education. In the study, the descriptive research model is used and qualitative research techniques are utilized. The study population consists of the students attending the 23 universities which has Music Education Department. The sample of the study consists of 438 girls and 312 boys, totally 750 students  who are studying in the Department of Music Education of randomly selected 10 universities. As a result of the explanatory and confirmatory factor analyses that were performed, a one-dimensional structure consisting of 14 items was obtained. Also, t-scores and  the coefficient scores of total item correlation concerning the distinguishing power of the items, the difference in the scores of the set of lower and upper 27% was calculated, and it was observed that the items are distinguishing as a result of both analyses. Of the scale, Cronbach's alpha coefficient of internal consistency was calculated as .94, and test-retest reliability coefficient was calculated as .93. As a result, a valid and reliable assessment and evaluation instrument that measures the exam performance anxiety of the students studying in the Department of Music Education, has been developed.Extended AbstractsIntroductionAnxiety is a universal phenomenon which people experience once or a few times during lives. It was accepted as concern for the future or as an unpleasant emotional experience regarding probable hitches of the events (Di Tomasso & Gosch, 2002.In general, the occasions on which negative feelings are experienced cause anxiety to arise (Baltaş and Baltaş, 2000. People also feel anxious in dangerous situations. Anxiety may lead a person to be creative, while it may have hindering characteristics. Anxiety is that an individual considers him

  4. A new design of neutron survey instrument

    International Nuclear Information System (INIS)

    Tanner, R.J.; Eakins, J.S.; Hager, L.G.

    2010-01-01

    A novel design of neutron survey instrument has been developed. The moderator has been modified via the use of 'neutron guides', which help thermal neutrons reach the central proportional counter. This innovation has allowed the variations in the energy dependence of ambient dose equivalent response to be reduced compared to prior single-detector designs, whilst maintaining a relatively light moderator and simple construction. In particular, the design has a relatively small over-response to neutrons with energies around 5 keV, when compared to prior designs. The final optimized design has been verified using MCNP5 calculations to ensure that the response is relatively independent of the energy and direction of the incident neutron. This has required the ends of the guides to be structured so that unidirectional and isotropic neutron fields have closely matched responses, as is necessary in the workplace. The reading of the instrument in workplace fields is calculated via folding and the suitability of the design for use in the workplace discussed.

  5. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. I. INSTRUMENT DESCRIPTION AND FIRST RESULTS

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Veillette, Daniel R.; Shah, Sagar C.; O'Rielly, Grant V.; Baena Galle, Roberto; Van Altena, William F.

    2009-01-01

    First results of a new speckle imaging system, the Differential Speckle Survey Instrument, are reported. The instrument is designed to take speckle data in two filters simultaneously with two independent CCD imagers. This feature results in three advantages over other speckle cameras: (1) twice as many frames can be obtained in the same observation time which can increase the signal-to-noise ratio for astrometric measurements, (2) component colors can be derived from a single observation, and (3) the two colors give substantial leverage over atmospheric dispersion, allowing for subdiffraction-limited separations to be measured reliably. Fifty-four observations are reported from the first use of the instrument at the Wisconsin-Indiana-Yale-NOAO 3.5 m Telescope 9 The WIYN Observatory is a joint facility of the University of Wisconsin-Madison, Indiana University, Yale University, and the National Optical Astronomy Observatories. in 2008 September, including seven components resolved for the first time. These observations are used to judge the basic capabilities of the instrument.

  6. Can Reliability of Multiple Component Measuring Instruments Depend on Response Option Presentation Mode?

    Science.gov (United States)

    Menold, Natalja; Raykov, Tenko

    2016-01-01

    This article examines the possible dependency of composite reliability on presentation format of the elements of a multi-item measuring instrument. Using empirical data and a recent method for interval estimation of group differences in reliability, we demonstrate that the reliability of an instrument need not be the same when polarity of the…

  7. Diagnosing paratonia in the demented elderly: reliability and validity of the Paratonia Assessment Instrument (PAI).

    Science.gov (United States)

    Hobbelen, Johannes S M; Koopmans, Raymond T C M; Verhey, Frans R J; Habraken, Kitty M; de Bie, Rob A

    2008-08-01

    Paratonia is one of the associated movement disorders characteristic of dementia. The aim of this study was to develop an assessment tool (the Paratonia Assessment Instrument, PAI), based on the new consensus definition of paratonia. An additional aim was to investigate the reliability and validity of the PAI. A three-phase cross-sectional survey was conducted. In the first two phases, the PAI was developed and validated. In the third phase, the inter-observer reliability and feasibility of the instrument was tested. The original PAI consisted of five criteria that all needed to be met in order to make the diagnosis. On the basis of a qualitative analysis, one criterion was reformulated and another was removed. Following this, inter-observer reliability between the two assessors resulted in an improvement of Cohen's kappa from 0.532 in the initial phase to 0.677 in the second phase. This improvement was substantiated in the third phase by two independent assessors with Cohen's kappa ranging from 0.625 to 1. The PAI is a reliable and valid assessment tool for diagnosing paratonia in elderly people with dementia that can be applied easily in daily practice.

  8. Lateral Violence in Nursing Survey: Instrument Development and Validation

    Directory of Open Access Journals (Sweden)

    Lynne S. Nemeth

    2017-07-01

    Full Text Available An examination of the psychometric properties of the Lateral Violence in Nursing Survey (LVNS, an instrument previously developed to measure the perceived incidence and severity of lateral violence (LV in the nursing workplace, was carried out. Conceptual clustering and principal components analysis were used with survey responses from 663 registered nurses and ancillary nursing staff in a southeastern tertiary care medical center. Where appropriate, Cronbach’s alpha (α evaluated internal consistency. The prevalence/severity of lateral violence items constitute two distinct subscales (LV by self and others with Cronbach’s alpha of 0.74 and 0.86, respectively. The items asking about potential causes of LV are unidimensional and internally consistent (alpha = 0.77 but there is no conceptually coherent theme underlying the various causes. Respondents rating a potential LV cause as “major” scored higher on both prevalence/severity subscales than those rating it a “minor” cause or not a cause. Subsets of items on the LVNS are internally reliable, supporting construct validity. Revisions of the original LVNS instrument will improve its use in future work.

  9. Reliability Analysis of Public Survey in Satisfaction with Nuclear Safety

    Energy Technology Data Exchange (ETDEWEB)

    Park, Moon Soo; Moon, Joo Hyun; Kang, Chang Sun [Seoul National Univ., Seoul (Korea, Republic of)

    2005-07-01

    Korea Institute of Nuclear Safety (KINS) carried out a questionnaire survey on public's understanding nuclear safety and regulation in order to grasp public acceptance for nuclear energy. The survey was planned to help to analyze public opinion on nuclear energy and provide basic data for advertising strategy and policy development. In this study, based on results of the survey, the reliability of the survey was evaluated according to each nuclear site.

  10. Reliability Analysis of Public Survey in Satisfaction with Nuclear Safety

    International Nuclear Information System (INIS)

    Park, Moon Soo; Moon, Joo Hyun; Kang, Chang Sun

    2005-01-01

    Korea Institute of Nuclear Safety (KINS) carried out a questionnaire survey on public's understanding nuclear safety and regulation in order to grasp public acceptance for nuclear energy. The survey was planned to help to analyze public opinion on nuclear energy and provide basic data for advertising strategy and policy development. In this study, based on results of the survey, the reliability of the survey was evaluated according to each nuclear site

  11. New generation low power radiation survey instruments

    International Nuclear Information System (INIS)

    Waechter, D.A.; Bjarke, G.O.; Trujillo, F.; Umbarger, C.J.; Wolf, M.A.

    1984-01-01

    A number of new, ultra-low-powered radiation instruments have recently been developed at Los Alamos. Among these are two instruments which use a novel power source to eliminate costly batteries. The newly developed gamma detecting radiac, nicknamed the Firefly, and the alpha particle detecting instrument, called the Simple Cordless Alpha Monitor, both use recent advances in miniaturization and powersaving electronics to yield devices which are small, rugged, and very power-frugal. The two instruments consume so little power that the need for batteries to run them is eliminated. They are, instead, powered by a charged capacitor which will operate the instruments for an hour or more. Use of a capacitor as a power source eliminates many problems commonly associated with battery-operated instruments, such as having to open the case to change batteries, battery storage life, availability of batteries in the field, and some savings in weight. Both line power and mechanical sources are used to charge the storage capacitors which power the instruments

  12. An Exploratory Factor Analysis and Reliability Analysis of the Student Online Learning Readiness (SOLR) Instrument

    Science.gov (United States)

    Yu, Taeho; Richardson, Jennifer C.

    2015-01-01

    The purpose of this study was to develop an effective instrument to measure student readiness in online learning with reliable predictors of online learning success factors such as learning outcomes and learner satisfaction. The validity and reliability of the Student Online Learning Readiness (SOLR) instrument were tested using exploratory factor…

  13. Instrument for assessing mobile technology acceptability in diabetes self-management: a validation and reliability study.

    Science.gov (United States)

    Frandes, Mirela; Deiac, Anca V; Timar, Bogdan; Lungeanu, Diana

    2017-01-01

    Nowadays, mobile technologies are part of everyday life, but the lack of instruments to assess their acceptability for the management of chronic diseases makes their actual adoption for this purpose slow. The objective of this study was to develop a survey instrument for assessing patients' attitude toward and intention to use mobile technology for diabetes mellitus (DM) self-management, as well as to identify sociodemographic characteristics and quality of life factors that affect them. We first conducted the documentation and instrument design phases, which were subsequently followed by the pilot study and instrument validation. Afterward, the instrument was administered 103 patients (median age: 37 years; range: 18-65 years) diagnosed with type 1 or type 2 DM, who accepted to participate in the study. The reliability and construct validity were assessed by computing Cronbach's alpha and using factor analysis, respectively. The instrument included statements about the actual use of electronic devices for DM management, interaction between patient and physician, attitude toward using mobile technology, and quality of life evaluation. Cronbach's alpha was 0.9 for attitude toward using mobile technology and 0.97 for attitude toward using mobile device applications for DM self-management. Younger patients (Spearman's ρ =-0.429; P higher education level (Kendall's τ =0.51; P mobile assistive applications for DM control. Moreover, patients with a higher quality of life presented a significantly more positive attitude toward using modern technology (Spearman's ρ =0.466; P mobile technology for DM self-management. Additionally, we found that even if most of the patients showed positive attitude toward mobile applications, only a moderate level of intention to indeed use them was observed. Moreover, the study indicated that barriers were truthfulness and easiness to use.

  14. Reliability of a Retail Food Store Survey and Development of an Accompanying Retail Scoring System to Communicate Survey Findings and Identify Vendors for Healthful Food and Marketing Initiatives

    Science.gov (United States)

    Ghirardelli, Alyssa; Quinn, Valerie; Sugerman, Sharon

    2011-01-01

    Objective: To develop a retail grocery instrument with weighted scoring to be used as an indicator of the food environment. Participants/Setting: Twenty six retail food stores in low-income areas in California. Intervention: Observational. Main Outcome Measure(s): Inter-rater reliability for grocery store survey instrument. Description of store…

  15. Reliability of patient specific instrumentation in total knee arthroplasty.

    Science.gov (United States)

    Jennart, Harold; Ngo Yamben, Marie-Ange; Kyriakidis, Theofylaktos; Zorman, David

    2015-12-01

    The aim of this study was to compare the precision between Patient Specific Instrumentation (PSI) and Conventional Instrumentation (CI) as determined intra-operatively by a pinless navigation system. Eighty patients were included in this prospective comparative study and they were divided into two homogeneous groups. We defined an original score from 6 to 30 points to evaluate the accuracy of the position of the cutting guides. This score is based on 6 objective criteria. The analysis indicated that PSI was not superior to conventional instrumentation in the overall score (p = 0.949). Moreover, no statistically significant difference was observed for any individual criteria of our score. Level of evidence II.

  16. The Assumption of a Reliable Instrument and Other Pitfalls to Avoid When Considering the Reliability of Data

    Science.gov (United States)

    Nimon, Kim; Zientek, Linda Reichwein; Henson, Robin K.

    2012-01-01

    The purpose of this article is to help researchers avoid common pitfalls associated with reliability including incorrectly assuming that (a) measurement error always attenuates observed score correlations, (b) different sources of measurement error originate from the same source, and (c) reliability is a function of instrumentation. To accomplish our purpose, we first describe what reliability is and why researchers should care about it with focus on its impact on effect sizes. Second, we review how reliability is assessed with comment on the consequences of cumulative measurement error. Third, we consider how researchers can use reliability generalization as a prescriptive method when designing their research studies to form hypotheses about whether or not reliability estimates will be acceptable given their sample and testing conditions. Finally, we discuss options that researchers may consider when faced with analyzing unreliable data. PMID:22518107

  17. System 80+ instrumentation and controls - certification of a reliable design

    International Nuclear Information System (INIS)

    Matzie, R.A.; Scarola, K.; Turk, R.S.

    1993-01-01

    ABB Combustion Engineering's (ABB) System 80+ advanced light water plant design includes a modern, fully digitized instrumentation and controls complex, Nuplex 80+. This complex incorporates an evolutionary advanced control room, replacing conventional analog instruments with more capable computer driven components. As a result, Nuplex 80+ results in significant improvements in operator information handling and control to enhance plant safety and availability. The design implements features which the U.S. NRC has determined to be acceptable for addressing the potential for common mode failure in software implemented for protective functions. (author)

  18. Reliability of Instruments Measuring At-Risk and Problem Gambling Among Young Individuals

    DEFF Research Database (Denmark)

    Edgren, Robert; Castrén, Sari; Mäkelä, Marjukka

    2016-01-01

    This review aims to clarify which instruments measuring at-risk and problem gambling (ARPG) among youth are reliable and valid in light of reported estimates of internal consistency, classification accuracy, and psychometric properties. A systematic search was conducted in PubMed, Medline, and Psyc......Info covering the years 2009–2015. In total, 50 original research articles fulfilled the inclusion criteria: target age under 29 years, using an instrument designed for youth, and reporting a reliability estimate. Articles were evaluated with the revised Quality Assessment of Diagnostic Accuracy Studies tool....... Reliability estimates were reported for five ARPG instruments. Most studies (66%) evaluated the South Oaks Gambling Screen Revised for Adolescents. The Gambling Addictive Behavior Scale for Adolescents was the only novel instrument. In general, the evaluation of instrument reliability was superficial. Despite...

  19. Chemical ionisation mass spectrometry: a survey of instrument technology

    International Nuclear Information System (INIS)

    Mather, R.E.; Todd, J.F.J.

    1979-01-01

    The purpose of this review is to survey the innovations and improvements which have been made in both instrumentation and methodology in chemical ionization mass spectrometry in the past ten years. (Auth.)

  20. Instrument reliability for high-level nuclear-waste-repository applications

    International Nuclear Information System (INIS)

    Rogue, F.; Binnall, E.P.; Armantrout, G.A.

    1983-01-01

    Reliable instrumentation will be needed to evaluate the characteristics of proposed high-level nuclear-wasted-repository sites and to monitor the performance of selected sites during the operational period and into repository closure. A study has been done to assess the reliability of instruments used in Department of Energy (DOE) waste repository related experiments and in other similar geological applications. The study included experiences with geotechnical, hydrological, geochemical, environmental, and radiological instrumentation and associated data acquisition equipment. Though this paper includes some findings on the reliability of instruments in each of these categories, the emphasis is on experiences with geotechnical instrumentation in hostile repository-type environments. We review the failure modes, rates, and mechanisms, along with manufacturers modifications and design changes to enhance and improve instrument performance; and include recommendations on areas where further improvements are needed

  1. Inexpensive microwave survey instruments: an evaluation

    International Nuclear Information System (INIS)

    Herman, W.A.; Witters, D.M. Jr.

    1979-11-01

    Instruments were tested. Depending upon the oven modulation and leak location these tests show that the Micromate will yield a warning reading at levels from 0.6 to 1.9 mW/cm 2 , when the effects of modulation sensitivity and polarization ellipticity are considered. It is to be expected, then, that this instrument will yield warning readings even when the oven emission being measured lies well within applicable standards. Its apparent susceptibility to overload damage, however, could decrease its sensitivity with no clue to the user as to what had happened. Given the same considerations and parameters, the tests show that the Guard-Rod will yield a warning reading at levels from 3.7 to 47 mW/cm 2 , depending on which measurement surface is used. This instrument will sometimes yield warnings for oven emissions lying within applicable standards, and sometimes will fail to yield such warnings for emissions 10 times greater than allowable levels. The same considerations show that the Interceptor/Microscan units will light up at levels from as low as 0.7 to 0.8 mW/cm 2 or may require levels of 7 to 9 mW/cm 2 . At levels of 28 to 52 mW/cm 2 or higher, however, the warning LED does not light. If part of the field is cross-polarized, this threshold of extinction may be greater. In any case, there is no apparent way for the user to discern the presence of some potentially hazardous fields, and no way to distinguish such fields from a very low-level field. In summary, instruments of the Interceptor/Microscan design may light up at very low power densities, but fail to light at very high power densities. Clearly, this characteristic is extremely undesirable and potentially dangerous to a user relying on such a device.All of these values assume that the instruments are used in accordance with manufacturer's instructions. Otherwise, results may be worse. Moreover, the range of values given take little or no account of unit-to-unit variation, which may be considerable

  2. Proceedings of the workshop on radiation survey instruments and calibrations

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Vallario, E.J.; Murphy, B.L.

    1985-11-01

    The workshop was held to discuss two topics: first, a performance standard for radiation survey instruments and the potential for a testing program based on that standard; and second, a system of secondary standards laboratories to provide instrument calibrations and related services. Separate abstracts have been prepared for the individual presentations

  3. Validity and Reliability of Turkish Male Breast Self-Examination Instrument.

    Science.gov (United States)

    Erkin, Özüm; Göl, İlknur

    2018-04-01

    This study aims to measure the validity and reliability of Turkish male breast self-examination (MBSE) instrument. The methodological study was performed in 2016 at Ege University, Faculty of Nursing, İzmir, Turkey. The MBSE includes ten steps. For validity studies, face validity, content validity, and construct validity (exploratory factor analysis) were done. For reliability study, Kuder Richardson was calculated. The content validity index was found to be 0.94. Kendall W coefficient was 0.80 (p=0.551). The total variance explained by the two factors was found to be 63.24%. Kuder Richardson 21 was done for reliability study and found to be 0.97 for the instrument. The final instrument included 10 steps and two stages. The Turkish version of MBSE is a valid and reliable instrument for early diagnose. The MBSE can be used in Turkish speaking countries and cultures with two stages and 10 steps.

  4. Calibration of dosemeters and survey instruments for photon

    International Nuclear Information System (INIS)

    Alamares, A.L.; Caseria, E.S.

    1995-01-01

    The Philippine Nuclear Research Institute (PNRI), the country's regulatory agency, through its Radiation Protection Unit of the Nuclear Regulations Licensing and Safeguard Division provides the calibration services of nuclear instruments used by various institutions. The periodic calibration and standardization of radiation and protection survey instruments are done to insure correct and valid radiation readings. It is also a regulatory requirement for radiation workers to use only operable and precalibrated survey instruments for their work with radioactive materials. The PNRI maintains and operates the Secondary Standard Dosimetry Laboratory (SSDL). It provides the periodic calibration and standardization of radiation monitoring and protection survey instruments, and also the radiological hazard and performance evaluation surveys of radiotherapy facilities and others. For the calibration of survey instruments, the standard sources of Cs-137 and Co-60 are used. The calibration procedures for survey meters and pocket dosimeters are explained. The clients served are shown. The personnel dosimetry using film badges, the application of ICRU operational quantities, and the problems encountered and recommendations are reported. (K.I.)

  5. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys.

    Science.gov (United States)

    van den Akker-Scheek, Inge; van Raay, Jos J A M; Reininga, Inge H F; Bulstra, Sjoerd K; Zijlstra, Wiebren; Stevens, Martin

    2010-10-19

    Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting.

  6. The Dark Energy Survey instrument design

    International Nuclear Information System (INIS)

    Flaugher, B.; Fermilab

    2006-01-01

    We describe a new project, the Dark Energy Survey (DES), aimed at measuring the dark energy equation of state parameter, w, to a statistical precision of ∼5%, with four complementary techniques. The survey will use a new 3 sq. deg. mosaic camera (DECam) mounted at the prime focus of the Blanco 4m telescope at the Cerro-Tololo International Observatory (CTIO). DECam includes a large mosaic camera, a five element optical corrector, four filters (g,r,i,z), and the associated infrastructure for operation in the prime focus cage. The focal plane consists of 62 2K x 4K CCD modules (0.27''/pixel) arranged in a hexagon inscribed within the 2.2 deg. diameter field of view. We plan to use the 250 micron thick fully-depleted CCDs that have been developed at the Lawrence Berkeley National Laboratory (LBNL). At Fermilab, we will establish a packaging factory to produce four-side buttable modules for the LBNL devices, as well as to test and grade the CCDs. R and D is underway and delivery of DECam to CTIO is scheduled for 2009

  7. Reliability and validity of instruments measuring job satisfaction - a systematic review

    NARCIS (Netherlands)

    van Saane, N.; Sluiter, J. K.; Verbeek, J. H. A. M.; Frings-Dresen, M. H. W.

    2003-01-01

    Background Although job satisfaction research has been carried out for decades, no recent overview of job satisfaction instruments and their quality is available. Aim The aim of this systematic review is to select job satisfaction instruments of adequate reliability and validity for use as

  8. Intrajudge and Interjudge Reliability of the Stuttering Severity Instrument-Fourth Edition.

    Science.gov (United States)

    Davidow, Jason H; Scott, Kathleen A

    2017-11-08

    The Stuttering Severity Instrument (SSI) is a tool used to measure the severity of stuttering. Previous versions of the instrument have known limitations (e.g., Lewis, 1995). The present study examined the intra- and interjudge reliability of the newest version, the Stuttering Severity Instrument-Fourth Edition (SSI-4) (Riley, 2009). Twelve judges who were trained on the SSI-4 protocol participated. Judges collected SSI-4 data while viewing 4 videos of adults who stutter at Time 1 and 4 weeks later at Time 2. Data were analyzed for intra- and interjudge reliability of the SSI-4 subscores (for Frequency, Duration, and Physical Concomitants), total score, and final severity rating. Intra- and interjudge reliability across the subscores and total score concurred with the manual's reported reliability when reliability was calculated using the methods described in the manual. New calculations of judge agreement produced different values from those in the manual-for the 3 subscores, total score, and final severity rating-and provided data absent from the manual. Clinicians and researchers who use the SSI-4 should carefully consider the limitations of the instrument. Investigation into the multitasking demands of the instrument may provide information on whether separating the collection of data for specific variables will improve intra- and interjudge reliability of those variables.

  9. Instrument evaluation no. 33. Automess Szintomat 6134 radiation survey meter

    International Nuclear Information System (INIS)

    McClure, D.R.

    1986-04-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This instrument evaluation report deals with the Automess Szintomat 6134 Radiation Survey Meter

  10. [Development and reliability evaluation of an instrument to measure health-related quality of life in independent elderly].

    Science.gov (United States)

    Lima, Maria José Barbosa de; Portela, Margareth Crisóstomo

    2010-08-01

    This study presents an instrument, the health-related quality of life (HRQOL) profile for independent elderly, to measure the health-related quality of life of the functionally independent elderly assisted in the outpatient setting, based on the adaptation of four validated scales: Short-Form Health Survey (SF-36), Duke-UNC Health Profile (DUHP), Sickness Impact Profile (SIP), and Nottingham Health Profile (NHP). The study also evaluates the instrument's reliability based on its use by two different observers with a 15-day interval. The instrument includes five dimensions (health perception, symptoms, physical function, psychological function, and social function) and 45 items. Reliability evaluation of the QUASI instrument was based on interviews with 142 elderly outpatients in the city of Rio de Janeiro, Brazil. Prevalence-adjusted kappa statistic was used to assess all 45 items. Correlation was also calculated between overall scores and scores on individual dimensions. In the reliability evaluation, 39 of the 45 items showed prevalence-adjusted kappa greater than 0.60.

  11. [French residents' training in instrumental deliveries: A national survey].

    Science.gov (United States)

    Saunier, C; Raimond, E; Dupont, A; Pelissier, A; Bonneau, S; Gabriel, R; Graesslin, O

    2016-11-01

    To evaluate French residents in Obstetrics and Gynaecology's training in instrumental deliveries in 2015. We conducted a national descriptive survey among 758 residents between December 2014 and January 2015. Respondents were invited by email to specify their University Hospital, their current university term, the number of instrumental deliveries performed by vacuum extractor, forceps or spatulas, and whether they made systematic ultrasound exams before performing the extraction. Response rate was 34.7 % (n=263). There were important differences between regions in terms of type of instruments used. Vacuum extractor was the most commonly used instrument for instrumental deliveries by French residents (56.9 %), more than forceps (25.2 %) and spatulas (17.9 %). At the end of the residency, all the residents had been trained in instrumental deliveries with at least two instruments. The training of difficult techniques as well as their perfect control is required for instrumental deliveries. Yet, we are forced to note that there are substantial differences in the French residents' training in instrumental deliveries depending on their region. So, teaching at least two techniques seems essential as well as improving the training capacities and standardizing practices. A greater systematization of the teaching of the mechanics and obstetric techniques might be a solution to be considered too. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  12. The Nutrition Literacy Assessment Instrument is a Valid and Reliable Measure of Nutrition Literacy in Adults with Chronic Disease.

    Science.gov (United States)

    Gibbs, Heather D; Ellerbeck, Edward F; Gajewski, Byron; Zhang, Chuanwu; Sullivan, Debra K

    2018-03-01

    To test the reliability and validity of the Nutrition Literacy Assessment Instrument (NLit) in adult primary care and identify the relationship between nutrition literacy and diet quality. This instrument validation study included a cross-sectional sample participating in up to 2 visits 1 month apart. A total of 429 adults with nutrition-related chronic disease were recruited from clinics and a patient registry affiliated with a Midwestern university medical center. Nutrition literacy was measured by the NLit, which was composed of 6 subscales: nutrition and health, energy sources in food, food label and numeracy, household food measurement, food groups, and consumer skills. Diet quality was measured by Healthy Eating Index-2010 with nutrient data from Diet History Questionnaire II surveys. The researchers measured factor validity and reliability by using binary confirmatory factor analysis; test-retest reliability was measured by Pearson r and the intraclass correlation coefficient, and relationships between nutrition literacy and diet quality were analyzed by linear regression. The NLit demonstrated substantial factor validity and reliability (0.97; confidence interval, 0.96-0.98) and test-retest reliability (0.88; confidence interval, 0.85-0.90). Nutrition literacy was the most significant predictor of diet quality (β = .17; multivariate coefficient = 0.10; P measuring nutrition literacy in adult primary care patients. Copyright © 2017 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  13. Measuring Workplace Travel Behaviour: Validity and Reliability of Survey Questions

    Directory of Open Access Journals (Sweden)

    Nicholas A. Petrunoff

    2013-01-01

    Full Text Available Background. The purpose of this study was to assess the (previously untested reliability and validity of survey questions commonly used to assess travel mode and travel time. Methods. Sixty-five respondents from a staff survey of travel behaviour conducted in a south-western Sydney hospital agreed to complete a travel diary for a week, wear an accelerometer over the same period, and twice complete an online travel survey an average of 21 days apart. The agreement in travel modes between the self-reported online survey and travel diary was examined with the kappa statistic. Spearman’s correlation coefficient was used to examine agreement of travel time from home to workplace measured between the self-reported online survey and four-day travel diary. Moderate-to-vigorous physical activity (MVPA time of active and nonactive travellers was compared by t-test. Results. There was substantial agreement between travel modes (K=0.62, P<0.0001 and a moderate correlation for travel time (ρ=0.75, P<0.0001 reported in the travel diary and online survey. There was a high level of agreement for travel mode (K=0.82, P<0.0001 and travel time (ρ=0.83, P<0.0001 between the two travel surveys. Accelerometer data indicated that for active travellers, 16% of the journey-to-work time is MVPA, compared with 6% for car drivers. Active travellers were significantly more active across the whole workday. Conclusions. The survey question “How did you travel to work this week? If you used more than one transport mode specify the one you used for the longest (distance portion of your journey” is reliable over 21 days and agrees well with a travel diary.

  14. Reliability and Validity of the Turkish Version of the Job Performance Scale Instrument.

    Science.gov (United States)

    Harmanci Seren, Arzu Kader; Tuna, Rujnan; Eskin Bacaksiz, Feride

    2018-02-01

    Objective measurement of the job performance of nursing staff using valid and reliable instruments is important in the evaluation of healthcare quality. A current, valid, and reliable instrument that specifically measures the performance of nurses is required for this purpose. The aim of this study was to determine the validity and reliability of the Turkish version of the Job Performance Instrument. This study used a methodological design and a sample of 240 nurses working at different units in four hospitals in Istanbul, Turkey. A descriptive data form, the Job Performance Scale, and the Employee Performance Scale were used to collect data. Data were analyzed using IBM SPSS Statistics Version 21.0 and LISREL Version 8.51. On the basis of the data analysis, the instrument was revised. Some items were deleted, and subscales were combined. The Turkish version of the Job Performance Instrument was determined to be valid and reliable to measure the performance of nurses. The instrument is suitable for evaluating current nursing roles.

  15. Applications of Calendar Instruments in Social Surveys: a review

    NARCIS (Netherlands)

    Glasner, T.J.; Vaart, van der W.

    2009-01-01

    Retrospective reports in survey interviews and questionnaires are subject to many types of recall error, which affect completeness, consistency, and dating accuracy. Concerns about this problem have led to the development of so-called calendar instruments, or timeline techniques. These aided recall

  16. Technical evaluation of available state of Nevada survey instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada`s Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC`s work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public.

  17. Technical evaluation of available state of Nevada survey instruments

    International Nuclear Information System (INIS)

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada's Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC's work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public

  18. Test - retest reliability of two instruments for measuring public attitudes towards persons with mental illness

    Directory of Open Access Journals (Sweden)

    Leufstadius Christel

    2011-01-01

    Full Text Available Abstract Background Research has identified stigmatization as a major threat to successful treatment of individuals with mental illness. As a consequence several anti-stigma campaigns have been carried out. The results have been discouraging and the field suffers from lack of evidence about interventions that work. There are few reports on psychometric data for instruments used to assess stigma, which thus complicates research efforts. The aim of the present study was to investigate test-retest reliability of the Swedish versions of the questionnaires: FABI and "Changing Minds" and to examine the internal consistency of the two instruments. Method Two instruments, fear and behavioural intentions (FABI and "Changing Minds", used in earlier studies on public attitudes towards persons with mental illness were translated into Swedish and completed by 51 nursing students on two occasions, with an interval of three weeks. Test-retest reliability was calculated by using weighted kappa coefficient and internal consistency using the Cronbach's alpha coefficient. Results Both instruments attain at best moderate test-retest reliability. For the Changing Minds questionnaire almost one fifth (17.9% of the items present poor test-retest reliability and the alpha coefficient for the subscales ranges between 0.19 - 0.46. All of the items in the FABI reach a fair or a moderate agreement between the test and retest, and the questionnaire displays a high internal consistency, alpha 0.80. Conclusions There is a need for development of psychometrically tested instruments within this field of research.

  19. Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength

    OpenAIRE

    Schans, van der, C.P.; Zijlstra, W.; Regterschot, G.R.H.; Krijnen, W.P.; Douma, K.W.; Slager, G.E.C.

    2016-01-01

    BACKGROUND: The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various d...

  20. A Reliability and Validity of an Instrument to Evaluate the School-Based Assessment System: A Pilot Study

    Science.gov (United States)

    Ghazali, Nor Hasnida Md

    2016-01-01

    A valid, reliable and practical instrument is needed to evaluate the implementation of the school-based assessment (SBA) system. The aim of this study is to develop and assess the validity and reliability of an instrument to measure the perception of teachers towards the SBA implementation in schools. The instrument is developed based on a…

  1. Reliability of instruments in a cooperative, multisite study: employment intervention demonstration program.

    Science.gov (United States)

    Salyers, M P; McHugo, G J; Cook, J A; Razzano, L A; Drake, R E; Mueser, K T

    2001-09-01

    Reliability of well-known instruments was examined in 202 people with severe mental illness participating in a multisite vocational study. We examined interrater reliability of the Positive and Negative Syndrome Scale (PANSS) and the internal consistency and test-retest reliability of the PANSS, the Rosenberg Self-Esteem Scale, the Medical Outcomes Study Short Form-36 (SF-36), and the Quality of Life Interview. Most scales had good levels of reliability, with intraclass correlation coefficients (ICCs) and coefficient alphas above .70. However, the SF-36 scales were generally less stable over time, particularly Social Functioning (ICC = .55). Test-retest reliability was lower among less educated respondents and among ethnic minorities. We recommend close monitoring of psychometric issues in future multisite studies.

  2. Translation, Validation, and Reliability of the Dutch Late-Life Function and Disability Instrument Computer Adaptive Test.

    Science.gov (United States)

    Arensman, Remco M; Pisters, Martijn F; de Man-van Ginkel, Janneke M; Schuurmans, Marieke J; Jette, Alan M; de Bie, Rob A

    2016-09-01

    Adequate and user-friendly instruments for assessing physical function and disability in older adults are vital for estimating and predicting health care needs in clinical practice. The Late-Life Function and Disability Instrument Computer Adaptive Test (LLFDI-CAT) is a promising instrument for assessing physical function and disability in gerontology research and clinical practice. The aims of this study were: (1) to translate the LLFDI-CAT to the Dutch language and (2) to investigate its validity and reliability in a sample of older adults who spoke Dutch and dwelled in the community. For the assessment of validity of the LLFDI-CAT, a cross-sectional design was used. To assess reliability, measurement of the LLFDI-CAT was repeated in the same sample. The item bank of the LLFDI-CAT was translated with a forward-backward procedure. A sample of 54 older adults completed the LLFDI-CAT, World Health Organization Disability Assessment Schedule 2.0, RAND 36-Item Short-Form Health Survey physical functioning scale (10 items), and 10-Meter Walk Test. The LLFDI-CAT was repeated in 2 to 8 days (mean=4.5 days). Pearson's r and the intraclass correlation coefficient (ICC) (2,1) were calculated to assess validity, group-level reliability, and participant-level reliability. A correlation of .74 for the LLFDI-CAT function scale and the RAND 36-Item Short-Form Health Survey physical functioning scale (10 items) was found. The correlations of the LLFDI-CAT disability scale with the World Health Organization Disability Assessment Schedule 2.0 and the 10-Meter Walk Test were -.57 and -.53, respectively. The ICC (2,1) of the LLFDI-CAT function scale was .84, with a group-level reliability score of .85. The ICC (2,1) of the LLFDI-CAT disability scale was .76, with a group-level reliability score of .81. The high percentage of women in the study and the exclusion of older adults with recent joint replacement or hospitalization limit the generalizability of the results. The Dutch LLFDI

  3. Diagnosing paratonia in the demented elderly : reliability and validity of the Paratonia Assessment Instrument (PAI)

    NARCIS (Netherlands)

    Hobbelen, Hans; Koopmans, Raymond T C M; Verhey, Frans R J; Habraken, Kitty M; de Bie, Rob A.

    BACKGROUND: Paratonia is one of the associated movement disorders characteristic of dementia. The aim of this study was to develop an assessment tool (the Paratonia Assessment Instrument, PAI), based on the new consensus definition of paratonia. An additional aim was to investigate the reliability

  4. Diagnosing paratonia in the demented elderly: reliability and validity of the Paratonia Assessment Instrument (PAI).

    NARCIS (Netherlands)

    Hobbelen, J.S.; Koopmans, R.T.C.M.; Verhey, F.R.J.; Habraken, K.M.; Bie, R.A. de

    2008-01-01

    BACKGROUND: Paratonia is one of the associated movement disorders characteristic of dementia. The aim of this study was to develop an assessment tool (the Paratonia Assessment Instrument, PAI), based on the new consensus definition of paratonia. An additional aim was to investigate the reliability

  5. Towards an Operational Definition of Effective Co-Teaching: Instrument Development, Validity, and Reliability

    Science.gov (United States)

    La Monte, Michelle Evonne

    2012-01-01

    This study focused on developing a valid and reliable instrument that can not only identify successful co-teaching, but also the professional development needs of co-teachers and their administrators in public schools. Two general questions about the quality of co-teaching were addressed in this study: (a) How well did descriptors within each of…

  6. Reliability of the Motor Learning Strategy Rating Instrument for Children and Youth with Acquired Brain Injury

    Science.gov (United States)

    Kamath, Trishna; Pfeifer, Megan; Banerjee-Guenette, Priyanka; Hunter, Theresa; Ito, Julia; Salbach, Nancy M.; Wright, Virginia; Levac, Danielle

    2012-01-01

    Purpose: To evaluate reliability and feasibility of the Motor Learning Strategy Rating Instrument (MLSRI) in children with acquired brain injury (ABI). The MLSRI quantifies the extent to which motor learning strategies (MLS) are used within physiotherapy (PT) interventions. Methods: PT sessions conducted by ABI team physiotherapists with a…

  7. The Effect of Instrument-Specific Rater Training on Interrater Reliability and Counseling Skills Performance Differentiation

    Science.gov (United States)

    Meacham, Paul Douglas, Jr.

    2013-01-01

    The purpose of this study was to explore the effect of instrument-specific rater training on interrater reliability (IRR) and counseling skills performance differentiation. Strong IRR is of primary concern to effective program evaluation (McCullough, Kuhn, Andrews, Valen, Hatch, & Osimo, 2003; Schanche, Nielsen, McCullough, Valen, &…

  8. The evaluation of equipment and Instrumentation Reliability Factors on Power Reactor

    International Nuclear Information System (INIS)

    Supriatna, Piping; Karlina, Itjeu; Widagdo, Suharyo; Santosa, Kussigit; Darlis; Sudiyono, Bambang; Yuniyanta, Sasongko; Sudarmin

    1999-01-01

    Equipment and instrumentation reliability on type power reactor control room was determined by its pattern and design. the principle of ergonomy applied on equipment and instrumentation layout in this ABWR type reactor are geometric pattern appropriate with economic body motion, average anthropometry data of operator especially operator hand-reach, range of vision, angle of vision, lighting, color arrangement and harmony as will as operator case in operating the equipment system. Limitation criteria of the parameter mentioned above are based on EPRI NP-3659, NURG 0700, and NUREG/CR-3331 documents. Besides that, the (working) physical environment parameter factor of the control room must be designed in order to fulfil the standard criteria of ergonomic condition based on NUREG-0800. The reliability evaluation of equipment and instrumentation system also occurs observed from man machine interaction side which happen between operator and equipment and instrumentation in the ABWR type power reactor control room. From the MMI analysis can be known the working failure possibility which is caused by the operator. The evaluation result of equipment and instrumentation reliability on ABWR type power reactor control room showed that the design of this ABWR control room is good and fulfils the ergonomy standard criteria have been determined

  9. Reliability assessment of a peer evaluation instrument in a team-based learning course

    Directory of Open Access Journals (Sweden)

    Wahawisan J

    2016-03-01

    Full Text Available Objective: To evaluate the reliability of a peer evaluation instrument in a longitudinal team-based learning setting. Methods: Student pharmacists were instructed to evaluate the contributions of their peers. Evaluations were analyzed for the variance of the scores by identifying low, medium, and high scores. Agreement between performance ratings within each group of students was assessed via intra-class correlation coefficient (ICC. Results: We found little variation in the standard deviation (SD based on the score means among the high, medium, and low scores within each group. The lack of variation in SD of results between groups suggests that the peer evaluation instrument produces precise results. The ICC showed strong concordance among raters. Conclusions: Findings suggest that our student peer evaluation instrument provides a reliable method for peer assessment in team-based learning settings.

  10. Reliability and Validity Study of the Attitude towards Mathematics Instruments Short Form

    Directory of Open Access Journals (Sweden)

    Güney HACIÖMEROĞLU

    2017-05-01

    Full Text Available Purpose of this study was to investigate the reliability and validity of the Turkish form of the Attitude Towards Mathematics Instrument Short Form developed by Lim and Chapman (2013. In this study, data gathered from 310 elementary students were utilized for Exploratory and Confirmatory Factor Analysis to determine the structure of factor loading. The factor loading among the sub-scales were different from original. Confirmatory Factor analysis revealed that the model was acceptable. There were three sub-scales, value, self-confidence, enjoyment and motivation. Cronbach’s alpha coefficient for the overall instrument was calculated as .84, respectively. The adapted instrument includes three sub-scales: value (α=.91, self-confidence (α=.86, enjoyment and motivation (α=.82. Turkish adaptation of the questionnaire is valid and reliable and appropriate to use in Turkish culture.

  11. Using Google Earth to conduct a neighborhood audit: reliability of a virtual audit instrument.

    Science.gov (United States)

    Clarke, Philippa; Ailshire, Jennifer; Melendez, Robert; Bader, Michael; Morenoff, Jeffrey

    2010-11-01

    Over the last two decades, the impact of community characteristics on the physical and mental health of residents has emerged as an important frontier of research in population health and health disparities. However, the development and evaluation of measures to capture community characteristics is still at a relatively early stage. The purpose of this work was to assess the reliability of a neighborhood audit instrument administered in the city of Chicago using Google Street View by comparing these "virtual" data to those obtained from an identical instrument administered "in-person". We find that a virtual audit instrument can provide reliable indicators of recreational facilities, the local food environment, and general land use. However, caution should be exercised when trying to gather more finely detailed observations. Using the internet to conduct a neighborhood audit has the potential to significantly reduce the costs of collecting data objectively and unobtrusively. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. Instrument and Survey Analysis Technical Report: Program Implementation Survey. Technical Report #1112

    Science.gov (United States)

    Alonzo, Julie; Tindal, Gerald

    2011-01-01

    This technical document provides guidance to educators on the creation and interpretation of survey instruments, particularly as they relate to an analysis of program implementation. Illustrative examples are drawn from a survey of educators related to the use of the easyCBM learning system. This document includes specific sections on…

  13. The Children's Play Therapy Instrument (CPTI): Description, Development, and Reliability Studies

    Science.gov (United States)

    Kernberg, Paulina F.; Chazan, Saralea E.; Normandin, Lina

    1998-01-01

    The Children's Play Therapy Instrument (CPTI), its development, and reliability studies are described. The CPTI is a new instrument to examine a child's play activity in individual psychotherapy. Three independent raters used the CPTI to rate eight videotaped play therapy vignettes. Results were compared with the authors' consensual scores from a preliminary study. Generally good to excellent levels of interrater reliability were obtained for the independent raters on intraclass correlation coefficients for ordinal categories of the CPTI. Likewise, kappa levels were acceptable to excellent for nominal categories of the scale. The CPTI holds promise to become a reliable measure of play activity in child psychotherapy. Further research is needed to assess discriminant validity of the CPTI for use as a diagnostic tool and as a measure of process and outcome.(The Journal of Psychotherapy Practice and Research 1998; 7:196–207) PMID:9631341

  14. The Children's Play Therapy Instrument (CPTI). Description, development, and reliability studies.

    Science.gov (United States)

    Kernberg, P F; Chazan, S E; Normandin, L

    1998-01-01

    The Children's Play Therapy Instrument (CPTI), its development, and reliability studies are described. The CPTI is a new instrument to examine a child's play activity in individual psychotherapy. Three independent raters used the CPTI to rate eight videotaped play therapy vignettes. Results were compared with the authors' consensual scores from a preliminary study. Generally good to excellent levels of interrater reliability were obtained for the independent raters on intraclass correlation coefficients for ordinal categories of the CPTI. Likewise, kappa levels were acceptable to excellent for nominal categories of the scale. The CPTI holds promise to become a reliable measure of play activity in child psychotherapy. Further research is needed to assess discriminant validity of the CPTI for use as a diagnostic tool and as a measure of process and outcome.

  15. Validity and reliability of the Turkish version of the pressure ulcer prevention knowledge assessment instrument.

    Science.gov (United States)

    Tulek, Zeliha; Polat, Cansu; Ozkan, Ilknur; Theofanidis, Dimitris; Togrol, Rifat Erdem

    2016-11-01

    Sound knowledge of pressure ulcers is important to enable good prevention. There are limited instruments assessing pressure ulcer knowledge. The Pressure Ulcer Prevention Knowledge Assessment Instrument is among the scales of which psychometric properties have been studied rigorously and reflects the latest evidence. This study aimed to evaluate the validity and reliability of the Turkish version of the Pressure Ulcer Prevention Knowledge Assessment Instrument (PUPKAI-T), an instrument that assesses knowledge of pressure ulcer prevention by using multiple-choice questions. Linguistic validity was verified through front-to-back translation. Psychometric properties of the instrument were studied on a sample of 150 nurses working in a tertiary hospital in Istanbul, Turkey. The content validity index of the translated instrument was 0.94, intra-class correlation coefficients were between 0.37 and 0.80, item difficulty indices were between 0.21 and 0.88, discrimination indices were 0.20-0.78, and the Kuder Richardson for the internal consistency was 0.803. The PUPKAI-T was found to be a valid and reliable tool to evaluate nurses' knowledge on pressure ulcer prevention. The PUPKAI-T may be a useful tool for determining educational needs of nurses on pressure ulcer prevention. Copyright © 2016 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  16. Rater reliability and concurrent validity of the Keyboard Personal Computer Style instrument (K-PeCS).

    Science.gov (United States)

    Baker, Nancy A; Cook, James R; Redfern, Mark S

    2009-01-01

    This paper describes the inter-rater and intra-rater reliability, and the concurrent validity of an observational instrument, the Keyboard Personal Computer Style instrument (K-PeCS), which assesses stereotypical postures and movements associated with computer keyboard use. Three trained raters independently rated the video clips of 45 computer keyboard users to ascertain inter-rater reliability, and then re-rated a sub-sample of 15 video clips to ascertain intra-rater reliability. Concurrent validity was assessed by comparing the ratings obtained using the K-PeCS to scores developed from a 3D motion analysis system. The overall K-PeCS had excellent reliability [inter-rater: intra-class correlation coefficients (ICC)=.90; intra-rater: ICC=.92]. Most individual items on the K-PeCS had from good to excellent reliability, although six items fell below ICC=.75. Those K-PeCS items that were assessed for concurrent validity compared favorably to the motion analysis data for all but two items. These results suggest that most items on the K-PeCS can be used to reliably document computer keyboarding style.

  17. Validity and Reliability of the Clinical Competency Evaluation Instrument for Use among Physiotherapy Students: Pilot study.

    Science.gov (United States)

    Muhamad, Zailani; Ramli, Ayiesah; Amat, Salleh

    2015-05-01

    The aim of this study was to determine the content validity, internal consistency, test-retest reliability and inter-rater reliability of the Clinical Competency Evaluation Instrument (CCEVI) in assessing the clinical performance of physiotherapy students. This study was carried out between June and September 2013 at University Kebangsaan Malaysia (UKM), Kuala Lumpur, Malaysia. A panel of 10 experts were identified to establish content validity by evaluating and rating each of the items used in the CCEVI with regards to their relevance in measuring students' clinical competency. A total of 50 UKM undergraduate physiotherapy students were assessed throughout their clinical placement to determine the construct validity of these items. The instrument's reliability was determined through a cross-sectional study involving a clinical performance assessment of 14 final-year undergraduate physiotherapy students. The content validity index of the entire CCEVI was 0.91, while the proportion of agreement on the content validity indices ranged from 0.83-1.00. The CCEVI construct validity was established with factor loading of ≥0.6, while internal consistency (Cronbach's alpha) overall was 0.97. Test-retest reliability of the CCEVI was confirmed with a Pearson's correlation range of 0.91-0.97 and an intraclass coefficient correlation range of 0.95-0.98. Inter-rater reliability of the CCEVI domains ranged from 0.59 to 0.97 on initial and subsequent assessments. This pilot study confirmed the content validity of the CCEVI. It showed high internal consistency, thereby providing evidence that the CCEVI has moderate to excellent inter-rater reliability. However, additional refinement in the wording of the CCEVI items, particularly in the domains of safety and documentation, is recommended to further improve the validity and reliability of the instrument.

  18. Human factors survey of advanced instrumentation and controls

    International Nuclear Information System (INIS)

    Carter, R.J.

    1989-01-01

    A survey oriented towards identifying the human factors issues in regard to the use of advanced instrumentation and controls (I ampersand C) in the nuclear industry was conducted. A number of United States (US) and Canadian nuclear vendors and utilities were participants in the survey. Human factors items, subsumed under the categories of computer-generated displays (CGD), controls, organizational support, training, and related topics, were discussed. The survey found the industry to be concerned about the human factors issues related to the implementation of advanced I ampersand C. Fifteen potential human factors problems were identified. They include: the need for an advanced I ampersand C guideline equivalent to NUREG-0700; a role change in the control room from operator to supervisor; information overload; adequacy of existing training technology for advanced I ampersand C; and operator acceptance and trust. 11 refs., 1 tab

  19. Measurements with the new PHE neutron survey instrument

    International Nuclear Information System (INIS)

    Eakins, J.S.; Tanner, R.J.; Hager, L.G.

    2014-01-01

    A novel design of survey instrument has been developed to accurately estimate ambient dose equivalent from neutrons with energies in the range from thermal to 20 MeV. The device features moderating and attenuating layers to ease measurement of fast and intermediate energy neutrons, combined with guides that channel low-energy neutrons to the single, central detector. A prototype of this device has been constructed and exposed to a set of calibration fields: the resulting measured responses are presented and discussed here, and compared against Monte Carlo data. A simple simulated workplace neutron field has also been developed to test the device. Measured response data have been determined for a prototype design of neutron survey instrument, using facilities at PHE and NPL. In general, the results demonstrated good directional invariance and agreed well with data obtained by Monte Carlo modelling, raising confidence in the accuracy of the response characteristics expected for the device. A simple simulated workplace field has also been developed and characterised, and the performance of the device assessed in it: agreement between measured and modelled results suggests that the device would behave as anticipated in real workplace fields. These performances will be investigated further in the future, as the design makes the transition from a research prototype to a commercially available instrument. (authors)

  20. Highly Reliable Power and Communication System for Essential Instruments under a Severe Accident of NPPs

    International Nuclear Information System (INIS)

    Yoo, S. J.; Choi, B. H.; Jung, S. Y.; Rim, Chun T.

    2013-01-01

    In this paper, three survivable strategies to overcome the problems listed above are proposed for the essential instruments under the severe accident of NPPs. First, wire/wireless multi power systems are adopted to the essential instruments for continuous power supply. Second, wire/wireless communication systems are proposed for reliable transmission of measuring information among instruments and operators. Third, a physical protection system such as a harness and a heat isolation box is introduced to ensure operable conditions for the proposed systems. In this paper, a highly reliable strategy, which consists of wire/wireless multi power and communication systems and physical protection system is proposed to ensure the survival of the essential instruments under harsh external conditions. The wire/wireless multi power and communication systems are designed to transfer power and data in spite of the failure of conventional wired systems. The physical protection system provides operable environments to the instruments. Therefore, the proposed system can be considered as a candidate of practical and urgent remedy for NPPs under the severe accident. After the Fukushima nuclear accident, survivability of essential instruments has been emphasized for immediate and accurate response. The essential instruments can measure environment conditions such as temperature, pressure, radioactivity and corium behavior inside nuclear power plants (NPPs) under a severe accident. Access to the inside of NPPs is restricted to human beings because of hazardous environment such as high radioactivity, high temperature and high pressure. Thus, monitoring the inside of NPPs is necessary for avoiding damage from the severe accident. Even though there were a number of instruments in Fukushima Daiichi NPP, they failed to obtain exact monitoring information. According to the details of the Fukushima nuclear accident, following problems can be counted as strong candidates of this instruments

  1. Highly Reliable Power and Communication System for Essential Instruments under a Severe Accident of NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, S. J.; Choi, B. H.; Jung, S. Y.; Rim, Chun T. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2013-10-15

    In this paper, three survivable strategies to overcome the problems listed above are proposed for the essential instruments under the severe accident of NPPs. First, wire/wireless multi power systems are adopted to the essential instruments for continuous power supply. Second, wire/wireless communication systems are proposed for reliable transmission of measuring information among instruments and operators. Third, a physical protection system such as a harness and a heat isolation box is introduced to ensure operable conditions for the proposed systems. In this paper, a highly reliable strategy, which consists of wire/wireless multi power and communication systems and physical protection system is proposed to ensure the survival of the essential instruments under harsh external conditions. The wire/wireless multi power and communication systems are designed to transfer power and data in spite of the failure of conventional wired systems. The physical protection system provides operable environments to the instruments. Therefore, the proposed system can be considered as a candidate of practical and urgent remedy for NPPs under the severe accident. After the Fukushima nuclear accident, survivability of essential instruments has been emphasized for immediate and accurate response. The essential instruments can measure environment conditions such as temperature, pressure, radioactivity and corium behavior inside nuclear power plants (NPPs) under a severe accident. Access to the inside of NPPs is restricted to human beings because of hazardous environment such as high radioactivity, high temperature and high pressure. Thus, monitoring the inside of NPPs is necessary for avoiding damage from the severe accident. Even though there were a number of instruments in Fukushima Daiichi NPP, they failed to obtain exact monitoring information. According to the details of the Fukushima nuclear accident, following problems can be counted as strong candidates of this instruments

  2. Establishing Reliability and Construct Validity for an Instrument to Measure Environmental Connectedness

    Science.gov (United States)

    Beery, Thomas H.

    2013-01-01

    The purpose of this preliminary study is to establish a reliable and valid measure of environmental connectedness (EC) to allow for further exploration of the Swedish Outdoor Recreation in Change national survey data. The Nordic concept of friluftsliv (nature-based outdoor recreation) and the environmental psychology concept of EC are explored to…

  3. The control-and-instrumentation system of the IEA zero power reactor and its reliability calculation

    International Nuclear Information System (INIS)

    Peluso, M.A.V.

    1978-01-01

    The control-and instrumentation system for the Instituto de Energia Atomica Zero Power Reactor is described and the design criteria are presented and discussed. The reliability analysis for the reactor protection system was performed using the fault tree method. This was done using a computer code based on the Monte Carlo simulation. That code is an adaptation of the SAFTE-I, for the IBM 360/155 IEA Computer. (Author) [pt

  4. Calibration of the GNU and HSREM neutron survey instruments

    Energy Technology Data Exchange (ETDEWEB)

    Eakins, J.S., E-mail: jonathan.eakins@phe.gov.uk [Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Hager, L.G. [Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Leake, J.W.; Mason, R.S. [Sherwood Nutec Scientific Ltd., Kent (United Kingdom); Tanner, R.J. [Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom)

    2017-04-21

    Two innovative designs of neutron survey instrument have recently been developed to estimate ambient dose equivalent in the workplace: the GNU has an improved energy-independence of response in the meV to TeV range; the HSREM is a comparatively lightweight device covering the meV to 10 MeV range. Both designs offer good detection sensitivity, allowing measurements to be made efficiently and thereby minimizing the exposure to their users. Prototypes of both devices have been constructed and exposed to sets of well-characterized reference fields: the resulting measured responses are presented and discussed here, compared against comprehensive Monte Carlo data.

  5. Calibration of the GNU and HSREM neutron survey instruments

    International Nuclear Information System (INIS)

    Eakins, J.S.; Hager, L.G.; Leake, J.W.; Mason, R.S.; Tanner, R.J.

    2017-01-01

    Two innovative designs of neutron survey instrument have recently been developed to estimate ambient dose equivalent in the workplace: the GNU has an improved energy-independence of response in the meV to TeV range; the HSREM is a comparatively lightweight device covering the meV to 10 MeV range. Both designs offer good detection sensitivity, allowing measurements to be made efficiently and thereby minimizing the exposure to their users. Prototypes of both devices have been constructed and exposed to sets of well-characterized reference fields: the resulting measured responses are presented and discussed here, compared against comprehensive Monte Carlo data.

  6. The modified patient enablement instrument: a Portuguese cross-cultural adaptation, validity and reliability study.

    Science.gov (United States)

    Remelhe, Mafalda; Teixeira, Pedro M; Lopes, Irene; Silva, Luís; Correia de Sousa, Jaime

    2017-01-12

    Enabling patients with asthma to obtain the knowledge, confidence and skills they need in order to assume a major role in the management of their disease is cost effective. It should be an integral part of any plan for long-term control of asthma. The modified Patient Enablement Instrument (mPEI) is an easily administered questionnaire that was adapted in the United Kingdom to measure patient enablement in asthma, but its applicability in Portugal is not known. Validity and reliability of questionnaires should be tested before use in settings different from those of the original version. The purpose of this study was to test the applicability of the mPEI to Portuguese asthma patients after translation and cross-cultural adaptation, and to verify the structural validity, internal consistency and reproducibility of the instrument. The mPEI was translated to Portuguese and back translated to English. Its content validity was assessed by a debriefing interview with 10 asthma patients. The translated instrument was then administered to a random sample of 142 patients with persistent asthma. Structural validity and internal consistency were assessed. For reproducibility analysis, 86 patients completed the instrument again 7 days later. Item-scale correlations and exploratory factor analysis were used to assess structural validity. Cronbach's alpha was used to test internal consistency, and the intra-class correlation coefficient was used for the analysis of reproducibility. All items of the Portuguese version of the mPEI were found to be equivalent to the original English version. There were strong item-scale correlations that confirmed construct validity, with a one component structure and good internal consistency (Cronbach's alpha >0.8) as well as high test-retest reliability (ICC=0.85). The mPEI showed sound psychometric properties for the evaluation of enablement in patients with asthma making it a reliable instrument for use in research and clinical practice in

  7. Validity and reliability of the Mastication Observation and Evaluation (MOE) instrument.

    Science.gov (United States)

    Remijn, Lianne; Speyer, Renée; Groen, Brenda E; van Limbeek, Jacques; Nijhuis-van der Sanden, Maria W G

    2014-07-01

    The Mastication Observation and Evaluation (MOE) instrument was developed to allow objective assessment of a child's mastication process. It contains 14 items and was developed over three Delphi rounds. The present study concerns the further development of the MOE using the COSMIN (Consensus based Standard for the Selection of Measurement Instruments) and investigated the instrument's internal consistency, inter-observer reliability, construct validity and floor and ceiling effects. Consumption of three bites of bread and biscuit was evaluated using the MOE. Data of 59 healthy children (6-48 mths) and 38 children (bread) and 37 children (biscuit) with cerebral palsy (24-72 mths) were used. Four items were excluded before analysis due to zero variance. Principal Components Analysis showed one factor with 8 items. Internal consistency was >0.70 (Chronbach's alpha) for both food consistencies and for both groups of children. Inter-observer reliability varied from 0.51 to 0.98 (weighted Gwet's agreement coefficient). The total MOE scores for both groups showed normal distribution for the population. There were no floor or ceiling effects. The revised MOE now contains 8 items that (a) have a consistent concept for mastication and can be scored on a 4-point scale with sufficient reliability and (b) are sensitive to stages of chewing development in young children. The removed items are retained as part of a criterion referenced list within the MOE. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Validity and reliability of a dental operator posture assessment instrument (PAI).

    Science.gov (United States)

    Branson, Bonnie G; Williams, Karen B; Bray, Kimberly Krust; Mcllnay, Sandy L; Dickey, Diana

    2002-01-01

    Basic operating posture is considered an important occupational health issue for oral health care clinicians. It is generally agreed that the physical posture of the operator, while providing care, should be such that all muscles are in a relaxed, well-balanced, and neutral position. Postures outside of this neutral position are likely to cause musculoskeletal discomfort. To date, the range of the neutral operator position has not been well-defined; nor have any specific instruments been identified that can quantitatively or semi-quantitatively assess dental operator posture. This paper reports on the development of an instrument that can be used to semi-quantitatively evaluate postural components. During the first phase of the study, an expert panel defined the basic parameters for acceptable, compromised, and harmful operator postures and established face validity of a posture assessment instrument (PAI). During the second phase, the PAI was tested for reliability using generalizability theory. Four raters tested the instrument for reliability. Overall, total PAI scores were similar amongst three of the raters, with the fourth rater's scores being slightly greater than the other three. The main effect of the rater on individual postural components was moderate, indicating that rater variance contributed to 11.9% of total variance. The PAI measures posture as it occurs and will have numerous applications when evaluating operator performance in the dental and dental hygiene education setting. Also, the PAI will prove useful when examining the effects of operator posture and musculoskeletal disorders.

  9. Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength.

    Science.gov (United States)

    Douma, K W; Regterschot, G R H; Krijnen, W P; Slager, G E C; van der Schans, C P; Zijlstra, W

    2016-01-01

    The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various degrees of extension. Measurements between 110 and 130° extension present the highest values and the most significant increase after training. The objective of this study is to determine the test-retest reliability of muscle strength measurements by the Q Force in older adults in 110° extension. Forty-one healthy older adults, 13 males and 28 females were included in the study. Mean (SD) age was 81.9 (4.89) years. Isometric muscle strength of the Quadriceps muscle was assessed with the Q Force at 110° of knee extension. Participants were measured at two sessions with a three to eight day interval between sessions. To determine relative reliability, the intraclass correlation coefficient (ICC) was calculated. To determine absolute reliability, Bland and Altman Limits of Agreement (LOA) were calculated and t-tests were performed. Relative reliability of the Q Force is good to excellent as all ICC coefficients are higher than 0.75. Generally a large 95 % LOA, reflecting only moderate absolute reliability, is found as exemplified for the peak torque left leg of -18.6 N to 33.8 N and the right leg of -9.2 N to 26.4 N was between 15.7 and 23.6 Newton representing 25.2 % to 39.9 % of the size of the mean. Small systematic differences in mean were found between measurement session 1 and 2. The present study shows that the Q Force has excellent relative test-retest reliability, but limited absolute test-retest reliability. Since the Q Force is relatively cheap and mobile it is suitable for

  10. Reliability, precision, and measurement in the context of data from ability tests, surveys, and assessments

    International Nuclear Information System (INIS)

    Fisher, W P Jr; Elbaum, B; Coulter, A

    2010-01-01

    Reliability coefficients indicate the proportion of total variance attributable to differences among measures separated along a quantitative continuum by a testing, survey, or assessment instrument. Reliability is usually considered to be influenced by both the internal consistency of a data set and the number of items, though textbooks and research papers rarely evaluate the extent to which these factors independently affect the data in question. Probabilistic formulations of the requirements for unidimensional measurement separate consistency from error by modelling individual response processes instead of group-level variation. The utility of this separation is illustrated via analyses of small sets of simulated data, and of subsets of data from a 78-item survey of over 2,500 parents of children with disabilities. Measurement reliability ultimately concerns the structural invariance specified in models requiring sufficient statistics, parameter separation, unidimensionality, and other qualities that historically have made quantification simple, practical, and convenient for end users. The paper concludes with suggestions for a research program aimed at focusing measurement research more on the calibration and wide dissemination of tools applicable to individuals, and less on the statistical study of inter-variable relations in large data sets.

  11. Study Abroad Survey Instruments: A Comparison of Survey Types and Experiences

    Science.gov (United States)

    Durrant, Marie Bradshaw; Dorius, Cassandra Rasmussen

    2007-01-01

    This study examines different survey instruments used to assess the experiences of U.S. study abroad participants. The intended audience is international and area study practitioners interested in assessing study abroad programs through postprogram interviews. An interview with the top 20 universities for number of students sent on study abroad…

  12. Low-Budget Instrumentation of a Conventional Leg Press to Measure Reliable Isometric-Strength Capacity.

    Science.gov (United States)

    Baur, Heiner; Groppa, Alessia Severina; Limacher, Regula; Radlinger, Lorenz

    2016-02-02

    Maximum strength and rate of force development (RFD) are 2 important strength characteristics for everyday tasks and athletic performance. Measurements of both parameters must be reliable. Expensive isokinetic devices with isometric modes are often used. The possibility of cost-effective measurements in a practical setting would facilitate quality control. The purpose of this study was to assess the reliability of measurements of maximum isometric strength (Fmax) and RFD on a conventional leg press. Sixteen subjects (23 ± 2 y, 1.68 ± 0.05 m, 59 ± 5 kg) were tested twice within 1 session. After warm-up, subjects performed 2 times 5 trials eliciting maximum voluntary isometric contractions on an instrumented leg press (1- and 2-legged randomized). Fmax (N) and RFD (N/s) were extracted from force-time curves. Reliability was determined for Fmax and RFD by calculating the intraclass correlation coefficient (ICC), the test-retest variability (TRV), and the bias and limits of agreement. Reliability measures revealed good to excellent ICCs of .80-.93. TRV showed mean differences between measurement sessions of 0.4-6.9%. The systematic error was low compared with the absolute mean values (Fmax 5-6%, RFD 1-4%). The implementation of a force transducer into a conventional leg press provides a viable procedure to assess Fmax and RFD. Both performance parameters can be assessed with good to excellent reliability allowing quality control of interventions.

  13. The reliability and validity of Cognitive Abilities Screening Instrument C-2.0 in Screening elderly people in Chengdu

    Institute of Scientific and Technical Information of China (English)

    Luo Zhuming; Lu Rong

    2000-01-01

    Background: Cognitive Abilities Screening Instrument C-2.0 (CASI C-2.0) is founded on Chinese culture apply to person with little or no formal education.Objective: In order to assess the reliability and validity of Cognitive Abilities Screening Instrument C-2.0 (CASI C-2.0), we surveyed 807 persons aged from 55 to 100 years and with little or no formal education in the town and country of Chengdu city. Methods: Phase I: 807 persona were assessed by different doctors with CASI C-2.0 and Mini mental State Examination (MMSE). Phase Ⅱ: The positive persons of phase I were assessed by trained field physicians who did not know the CASI C-2.0 and MMSE scores. The physicians assessment included a detail history, a systematic physical examination and a selected group of psychometric tests to ascertain the clinical diagnoses of dementia、 Alzheimer′s disease and vascular dementia utilizing the ICD-10 and NINCDS-ADRAD、 DSM-Ⅳ criteria respectively. Phase Ⅲ: 30 persons were retest with CASI C-2.0 randomly after 3--4 weeks. Results: Among the 807 persons, 55 cases of dementia were identified, including 50 cases of probable Alzheimer′s disease and 5 cases of vascular dementia. Discussion: On reliability, the test-retest reliability coefficient of CASI C-2.0 is 0.97,p<0.001, the person′s correlation coefficient between nine items scores and total scores are all above 0.66, the Cronback a is 0.9056, the split-half reliability coefficient is 0.8355. On validity, using ICD-10 criteria as ”Gold Criteria" and 50 as a cut-offscore, the sensitivity、 specificity、 accuracy of CASI C-2.0 are 94.5%、 89.5%、 89.8% respectively, kappa is 0.5123. Comparing with MMSE, CAS1 C-2.0 has a better specificity, x2 test, p<0.01; a same sensitivity; and a lower refusal answer ratio, x2 test, p<0.005. Conclusion: We consider that CASI C-2.0 has excellent reliability and validity. It is worthy of disseminating and applying for both clinical and epidemiological surveys.

  14. Automatic creation of Markov models for reliability assessment of safety instrumented systems

    International Nuclear Information System (INIS)

    Guo Haitao; Yang Xianhui

    2008-01-01

    After the release of new international functional safety standards like IEC 61508, people care more for the safety and availability of safety instrumented systems. Markov analysis is a powerful and flexible technique to assess the reliability measurements of safety instrumented systems, but it is fallible and time-consuming to create Markov models manually. This paper presents a new technique to automatically create Markov models for reliability assessment of safety instrumented systems. Many safety related factors, such as failure modes, self-diagnostic, restorations, common cause and voting, are included in Markov models. A framework is generated first based on voting, failure modes and self-diagnostic. Then, repairs and common-cause failures are incorporated into the framework to build a complete Markov model. Eventual simplification of Markov models can be done by state merging. Examples given in this paper show how explosively the size of Markov model increases as the system becomes a little more complicated as well as the advancement of automatic creation of Markov models

  15. Developing of Individual Instrument Performance Anxiety Scale: ValidityReliability Study

    Directory of Open Access Journals (Sweden)

    Esra DALKIRAN

    2016-07-01

    Full Text Available In this study, it is intended to develop a scale unique to our culture, concerning individual instrument performance anxiety of the students who are getting instrument training in the Department of Music Education. In the study, the descriptive research model is used and qualitative research techniques are utilized. The study population consists of the students attending the 23 universities which has Music Education Department. The sample of the study consists of 438 girls and 312 boys, totally 750 students who are studying in the Department of Music Education of randomly selected 10 universities. As a result of the explanatory and confirmatory factor analyses that were performed, a onedimensional structure consisting of 14 items was obtained. Also, t-scores and the coefficient scores of total item correlation concerning the distinguishing power of the items, the difference in the scores of the set of lower and upper 27% was calculated, and it was observed that the items are distinguishing as a result of both analyses. Of the scale, Cronbach's alpha coefficient of internal consistency was calculated as .94, and test-retest reliability coefficient was calculated as .93. As a result, a valid and reliable assessment and evaluation instrument that measures the exam performance anxiety of the students studying in the Department of Music Education, has been developed.

  16. Research in radiation monitoring survey instrumentation. Final report

    International Nuclear Information System (INIS)

    Blalock, T.V.; Kennedy, E.J.; Phillips, R.G.; Walker, E.W. Jr.

    1978-01-01

    Two low-power solid-state prototype readout units were developed, an LED display and a LCD display. This display output was in a bar-graph format, covering four-decades of information, with 10-segments per decade. The displays accept a frequency input, which is standardly available from several portable radiation-survey instruments. Both readout units will operate on two D-cell batteries (3.0 Volt), with a typical current drain requirement of 0.3 MA for the LED display and 30μA for the LCD display. A wide-range electrometer circuit was also developed. The circuit covers an input current range from 10 -13 A to 10 -8 A. The output signal is a pulse whose frequency is directly proportional to input current. The circuit requires no high-megohm resistors, and is autoranging. Several candidate input amplifiers were analyzed and evaluated for use with the electrometer circuit

  17. Under sodium reliability tests on core components and in-core instrumentation

    International Nuclear Information System (INIS)

    Ruppert, E.; Stehle, H.; Vinzens, K.

    1977-01-01

    A sodium test facility for fast breeder core components (AKB), built by INTERATOM at Bensberg, has been operating since 1971 to test fuel dummies and blanket elements as well as absorber elements under simulated normal and extreme reactor conditions. Individual full-scale fuel or blanket elements and arrays of seven elements, modelling a section of the SNR-300 reactor core, have been tested under a wide range of sodium mass flow and isothermal test conditions up to 925K as well as under cyclic changed temperature transients. Besides endurance testing of the core components a special sodium and high-temperature instrumentation is provided to investigate thermohydraulic and vibrational behaviour of the test objects. During all test periods the main subassembly characteristics could be reproduced and the reliability of the instrumentation could be proven. (orig.) [de

  18. International Survey on agriculture-climate change policy instruments

    Energy Technology Data Exchange (ETDEWEB)

    Fernagut, M.; Priem, M.; Sorgeloos, L.

    2011-09-15

    The title study provides an international overview of agriculture-climate change policy instruments for the reduction of methane and nitrous oxide emissions. The aim of this study is to clarify how national and/or international agriculture-climate-policies could or should be instrumented during the coming three to five years to achieve significant emission reductions of methane and nitrous oxide in the Dutch agricultural sector by 2020. The study includes an international survey, a quick-scan inventory of useful and inspiring examples of policy and reduction measures to reduce non CO2 greenhouse gases. ERM used an approach consisting out of three phases. In the first phase countries were selected on the basis of emissions and Kyoto protocol targets. In the second phase policy measures of these countries were listed, based on publicly available national and international sources. In a third phase a sub-set of this selection was analyzed in-depth through communications with local focal points and additional review of policy documents, to enhance the understanding of context, impact and results of each of these policies and measures.

  19. Good practices in normal childbirth: reliability analysis of an instrument by Cronbach's Alpha.

    Science.gov (United States)

    Gottems, Leila Bernarda Donato; Carvalho, Elisabete Mesquita Peres De; Guilhem, Dirce; Pires, Maria Raquel Gomes Maia

    2018-01-01

    to analyze the internal consistency of the evaluation instrument of the adherence to the good practices of childbirth and birth care in the professionals, through Cronbach's Alpha Coefficient for each of the dimensions and for the total instrument. this is a descriptive and cross-sectional study performed in obstetric centers of eleven public hospitals in the Federal District, with a questionnaire applied to 261 professionals who worked in the delivery care. The study was attended by 261 professionals, 42.5% (111) nurses and 57.5% (150) physicians. The reliability evaluation of the instrument by the Cronbach Alfa resulted in 0.53, 0.78 and 0.76 for dimensions 1, 2 and 3, after debugging that resulted in the exclusion of 11 items. the instrument obtained Cronbach's alpha of 0.80. There is a need for improvement in the items of dimension 1 that refer to attitudes, knowledge, and practices of the organization of the network of care to gestation, childbirth, and birth. However, it can be applied in the way it is used to evaluate practices based on scientific evidence of childbirth care.

  20. Design, validation, and reliability of survey to measure female athlete triad knowledge among coaches

    Directory of Open Access Journals (Sweden)

    Jillian E. Frideres

    2015-06-01

    Full Text Available The purpose of this study was to design and to test the validity and reliability of an instrument to evaluate coaches' knowledge about the female athlete triad syndrome and their confidence in this knowledge. The instrument collects information regarding: knowledge of the syndrome, components, prevention and intervention; confidence of the coaches in their answers; and coach's characteristics (gender, degree held, years of experience in coaching females, continuing education participation specific to the syndrome and its components, and sport coached. The process of designing the questionnaire and testing the validity and reliability of it was done in four phases: a design and development of the instrument, b content validity, c instrument reliability, and d concurrent validity. The results show that the instrument is suitable for measuring coaches' female athlete triad knowledge. The instrument can contribute to assessing the coaches' knowledge level in relation to this topic.

  1. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  2. Measuring children's self-reported sport participation, risk perception and injury history: development and validation of a survey instrument.

    Science.gov (United States)

    Siesmaa, Emma J; Blitvich, Jennifer D; White, Peta E; Finch, Caroline F

    2011-01-01

    Despite the health benefits associated with children's sport participation, the occurrence of injury in this context is common. The extent to which sport injuries impact children's ongoing involvement in sport is largely unknown. Surveys have been shown to be useful for collecting children's injury and sport participation data; however, there are currently no published instruments which investigate the impact of injury on children's sport participation. This study describes the processes undertaken to assess the validity of two survey instruments for collecting self-reported information about child cricket and netball related participation, injury history and injury risk perceptions, as well as the reliability of the cricket-specific version. Face and content validity were assessed through expert feedback from primary and secondary level teachers and from representatives of peak sporting bodies for cricket and netball. Test-retest reliability was measured using a sample of 59 child cricketers who completed the survey on two occasions, 3-4 weeks apart. Based on expert feedback relating to face and content validity, modification and/or deletion of some survey items was undertaken. Survey items with low test-retest reliability (κ≤0.40) were modified or deleted, items with moderate reliability (κ=0.41-0.60) were modified slightly and items with higher reliability (κ≥0.61) were retained, with some undergoing minor modifications. This is the first survey of its kind which has been successfully administered to cricketers aged 10-16 years to collect information about injury risk perceptions and intentions for continued sport participation. Implications for its generalisation to other child sport participants are discussed. Copyright © 2010 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  3. An instrument measuring prospective mathematics teacher self-regulated learning: validity and reliability

    Science.gov (United States)

    Nugroho, A. A.; Juniati, D.; Siswono, T. Y. E.

    2018-03-01

    Self Regulated Learning (SRL) is an individual's ability to achieve academic goals by controlling behavior, motivate yourself and use cognitive in learning, so it is important for a teacher especially teachers of mathematics related to the ability of management, design, implementation of learning and evaluation of learning outcomes. The purpose of the research is to develop an instrument to describe the SRL of a prospective mathematics teacher. Data were collected by (1) the study of the theory of SRL produced the indicator SRL used to design the questionnaire SRL; (2) analysis of the questionnaire SRL obtained from several References; and (3) development stage of the SRL questionnaire through validity test of content and empirical validation. The study involved 2 content experts in mathematics, 1 linguist, and 92 prospective mathematics teachers. The results of the research on content validity test based on Indonesian expert and 2 content experts indicate that the content can assess the indicator of the SRL and feasible to be used, in the test of legibility of two prospective mathematics teacher concluded that the instrument has a language that can be understood by the prospective teacher of mathematics and on empirical validation involving 92 prospective mathematics teacher generate data that of 65 statements there are 3 invalid statements. Reliability calculation shows high category that values 0,93. The conclusion is the SRL instrument developed for the prospective mathematics teacher.

  4. Test-retest reliability and cross validation of the functioning everyday with a wheelchair instrument.

    Science.gov (United States)

    Mills, Tamara L; Holm, Margo B; Schmeler, Mark

    2007-01-01

    The purpose of this study was to establish the test-retest reliability and content validity of an outcomes tool designed to measure the effectiveness of seating-mobility interventions on the functional performance of individuals who use wheelchairs or scooters as their primary seating-mobility device. The instrument, Functioning Everyday With a Wheelchair (FEW), is a questionnaire designed to measure perceived user function related to wheelchair/scooter use. Using consumer-generated items, FEW Beta Version 1.0 was developed and test-retest reliability was established. Cross-validation of FEW Beta Version 1.0 was then carried out with five samples of seating-mobility users to establish content validity. Based on the content validity study, FEW Version 2.0 was developed and administered to seating-mobility consumers to examine its test-retest reliability. FEW Beta Version 1.0 yielded an intraclass correlation coefficient (ICC) Model (3,k) of .92, p content validity results revealed that FEW Beta Version 1.0 captured 55% of seating-mobility goals reported by consumers across five samples. FEW Version 2.0 yielded ICC(3,k) = .86, p content validity of FEW Version 2.0 was confirmed. FEW Beta Version 1.0 and FEW Version 2.0 were highly stable in their measurement of participants' seating-mobility goals over a 1-week interval.

  5. Development and Reliability Evaluation of the Movement Rating Instrument for Virtual Reality Video Game Play.

    Science.gov (United States)

    Levac, Danielle; Nawrotek, Joanna; Deschenes, Emilie; Giguere, Tia; Serafin, Julie; Bilodeau, Martin; Sveistrup, Heidi

    2016-06-01

    Virtual reality active video games are increasingly popular physical therapy interventions for children with cerebral palsy. However, physical therapists require educational resources to support decision making about game selection to match individual patient goals. Quantifying the movements elicited during virtual reality active video game play can inform individualized game selection in pediatric rehabilitation. The objectives of this study were to develop and evaluate the feasibility and reliability of the Movement Rating Instrument for Virtual Reality Game Play (MRI-VRGP). Item generation occurred through an iterative process of literature review and sample videotape viewing. The MRI-VRGP includes 25 items quantifying upper extremity, lower extremity, and total body movements. A total of 176 videotaped 90-second game play sessions involving 7 typically developing children and 4 children with cerebral palsy were rated by 3 raters trained in MRI-VRGP use. Children played 8 games on 2 virtual reality and active video game systems. Intraclass correlation coefficients (ICCs) determined intra-rater and interrater reliability. Excellent intrarater reliability was evidenced by ICCs of >0.75 for 17 of the 25 items across the 3 raters. Interrater reliability estimates were less precise. Excellent interrater reliability was achieved for far reach upper extremity movements (ICC=0.92 [for right and ICC=0.90 for left) and for squat (ICC=0.80) and jump items (ICC=0.99), with 9 items achieving ICCs of >0.70, 12 items achieving ICCs of between 0.40 and 0.70, and 4 items achieving poor reliability (close-reach upper extremity-ICC=0.14 for right and ICC=0.07 for left) and single-leg stance (ICC=0.55 for right and ICC=0.27 for left). Poor video quality, differing item interpretations between raters, and difficulty quantifying the high-speed movements involved in game play affected reliability. With item definition clarification and further psychometric property evaluation, the MRI

  6. Dental Management Survey Brazil (DMS-BR): creation and validation of a management instrument

    Science.gov (United States)

    Gonzales, Paola Sampaio; Martins, Ismar Eduardo; Biazevic, Maria Gabriela Haye; Silva, Paulo Roberto da; Michel-Crosato, Edgard

    2017-04-10

    Questionnaires for the assessment of knowledge and self-perception can be useful to diagnose what a dentist knows about management and administration. The aim of the present study was to create and validate the Dental Management Survey Brazil (DMS-BR) scale, based on meetings with experts in the field. After having elaborated the first version, 10 audits were performed in dental offices in order to produce the final version, which included nine dimensions: location, patient, finance, marketing, competition, quality, staff, career, and productivity. The accuracy of the instrument was measured by intrarater and interrater reliability. In the validation phase, 247 Brazilian dentists answered a web-based questionnaire. The data were processed using Stata 13.0 and the significance level was set at 95%. The instrument had intrarater and interrater reliability (ICC-0.93 and 0.94). The overall average of respondents for the DMS-BR scale was 3.77 (SD = 0.45). Skewness and kurtosis were below absolute values 3 and 7, respectively. Internal validity measured by Cronbach's alpha was 0.925 and the correlation of each dimension with the final result of the DMS-BR ranged between 0.606 and 0.810. Correlation with the job satisfaction scale was 0.661. The SEM data ranged between 0.80 and 0.56. The questionnaire presented satisfactory indicators of dentists' self-perception about management and administration activities.

  7. A survey of NASA and military standards on fault tolerance and reliability applied to robotics

    Science.gov (United States)

    Cavallaro, Joseph R.; Walker, Ian D.

    1994-01-01

    There is currently increasing interest and activity in the area of reliability and fault tolerance for robotics. This paper discusses the application of Standards in robot reliability, and surveys the literature of relevant existing standards. A bibliography of relevant Military and NASA standards for reliability and fault tolerance is included.

  8. Development of an instrument for direct ozone production rate measurements: measurement reliability and current limitations

    Science.gov (United States)

    Sklaveniti, Sofia; Locoge, Nadine; Stevens, Philip S.; Wood, Ezra; Kundu, Shuvashish; Dusanter, Sébastien

    2018-02-01

    Ground-level ozone (O3) is an important pollutant that affects both global climate change and regional air quality, with the latter linked to detrimental effects on both human health and ecosystems. Ozone is not directly emitted in the atmosphere but is formed from chemical reactions involving volatile organic compounds (VOCs), nitrogen oxides (NOx = NO + NO2) and sunlight. The photochemical nature of ozone makes the implementation of reduction strategies challenging and a good understanding of its formation chemistry is fundamental in order to develop efficient strategies of ozone reduction from mitigation measures of primary VOCs and NOx emissions. An instrument for direct measurements of ozone production rates (OPRs) was developed and deployed in the field as part of the IRRONIC (Indiana Radical, Reactivity and Ozone Production Intercomparison) field campaign. The OPR instrument is based on the principle of the previously published MOPS instrument (Measurement of Ozone Production Sensor) but using a different sampling design made of quartz flow tubes and a different Ox (O3 and NO2) conversion-detection scheme composed of an O3-to-NO2 conversion unit and a cavity attenuated phase shift spectroscopy (CAPS) NO2 monitor. Tests performed in the laboratory and in the field, together with model simulations of the radical chemistry occurring inside the flow tubes, were used to assess (i) the reliability of the measurement principle and (ii) potential biases associated with OPR measurements. This publication reports the first field measurements made using this instrument to illustrate its performance. The results showed that a photo-enhanced loss of ozone inside the sampling flow tubes disturbs the measurements. This issue needs to be solved to be able to perform accurate ambient measurements of ozone production rates with the instrument described in this study. However, an attempt was made to investigate the OPR sensitivity to NOx by adding NO inside the instrument

  9. Investigating the Reliability and Factor Structure of Kalichman's "Survey 2: Research Misconduct" Questionnaire: A Post Hoc Analysis Among Biomedical Doctoral Students in Scandinavia.

    Science.gov (United States)

    Holm, Søren; Hofmann, Bjørn

    2017-10-01

    A precondition for reducing scientific misconduct is evidence about scientists' attitudes. We need reliable survey instruments, and this study investigates the reliability of Kalichman's "Survey 2: research misconduct" questionnaire. The study is a post hoc analysis of data from three surveys among biomedical doctoral students in Scandinavia (2010-2015). We perform reliability analysis, and exploratory and confirmatory factor analysis using a split-sample design as a partial validation. The results indicate that a reliable 13-item scale can be formed (Cronbach's α = .705), and factor analysis indicates that there are four reliable subscales each tapping a different construct: (a) general attitude to misconduct (α = .768), (b) attitude to personal misconduct (α = .784), (c) attitude to whistleblowing (α = .841), and (d) attitude to blameworthiness/punishment (α = .877). A full validation of the questionnaire requires further research. We, nevertheless, hope that the results will facilitate the increased use of the questionnaire in research.

  10. Reliability of the input admittance of bowed-string instruments measured by the hammer method.

    Science.gov (United States)

    Zhang, Ailin; Woodhouse, Jim

    2014-12-01

    The input admittance at the bridge, measured by hammer testing, is often regarded as the most useful and convenient measurement of the vibrational behavior of a bowed string instrument. However, this method has been questioned, due especially to differences between human bowing and hammer impact. The goal of the research presented here is to investigate the reliability and accuracy of this classic hammer method. Experimental studies were carried out on cellos, with three different driving conditions and three different boundary conditions. Results suggest that there is nothing fundamentally different about the hammer method, compared to other kinds of excitation. The third series of experiments offers an opportunity to explore the difference between the input admittance measuring from one bridge corner to another and that of single strings. The classic measurement is found to give a reasonable approximation to that of all four strings. Some possible differences between the hammer method and normal bowing and implications of the acoustical results are also discussed.

  11. Validity and reliability of an instrument for assessing case analyses in bioengineering ethics education.

    Science.gov (United States)

    Goldin, Ilya M; Pinkus, Rosa Lynn; Ashley, Kevin

    2015-06-01

    Assessment in ethics education faces a challenge. From the perspectives of teachers, students, and third-party evaluators like the Accreditation Board for Engineering and Technology and the National Institutes of Health, assessment of student performance is essential. Because of the complexity of ethical case analysis, however, it is difficult to formulate assessment criteria, and to recognize when students fulfill them. Improvement in students' moral reasoning skills can serve as the focus of assessment. In previous work, Rosa Lynn Pinkus and Claire Gloeckner developed a novel instrument for assessing moral reasoning skills in bioengineering ethics. In this paper, we compare that approach to existing assessment techniques, and evaluate its validity and reliability. We find that it is sensitive to knowledge gain and that independent coders agree on how to apply it.

  12. Incorporation of Markov reliability models for digital instrumentation and control systems into existing PRAs

    International Nuclear Information System (INIS)

    Bucci, P.; Mangan, L. A.; Kirschenbaum, J.; Mandelli, D.; Aldemir, T.; Arndt, S. A.

    2006-01-01

    Markov models have the ability to capture the statistical dependence between failure events that can arise in the presence of complex dynamic interactions between components of digital instrumentation and control systems. One obstacle to the use of such models in an existing probabilistic risk assessment (PRA) is that most of the currently available PRA software is based on the static event-tree/fault-tree methodology which often cannot represent such interactions. We present an approach to the integration of Markov reliability models into existing PRAs by describing the Markov model of a digital steam generator feedwater level control system, how dynamic event trees (DETs) can be generated from the model, and how the DETs can be incorporated into an existing PRA with the SAPHIRE software. (authors)

  13. Translation, cross-cultural adaptation to Brazilian- Portuguese and reliability analysis of the instrument Rapid Entire Body Assessment-REBA

    Directory of Open Access Journals (Sweden)

    Andressa M. Lamarão

    2014-06-01

    Full Text Available Background: Observational instruments, such as the Rapid Entire Body Assessment, quickly assess biomechanical risks present in the workplace. However, in order to use these instruments, it is necessary to conduct the translational/cross-cultural adaptation of the instrument and test its measurement properties. Objectives: To perform the translation and the cross-cultural adaptation to Brazilian-Portuguese and test the reliability of the REBA instrument. Method: The procedures of translation and cross-cultural adaptation to Brazilian-Portuguese were conducted following proposed guidelines that involved translation, synthesis of translations, back translation, committee review and testing of the pre-final version. In addition, reliability and the intra- and inter-rater percent agreement were obtained with the Linear Weighted Kappa Coefficient that was associated with the 95% Confidence Interval and the cross tabulation 2×2. Results : The procedures for translation and adaptation were adequate and the necessary adjustments were conducted on the instrument. The intra- and inter-rater reliability showed values of 0.104 to 0.504, respectively, ranging from very poor to moderate. The percentage agreement values ranged from 5.66% to 69.81%. The percentage agreement was closer to 100% at the item 'upper arm' (69.81% for the Intra-rater 1 and at the items 'legs' and 'upper arm' for the Intra-rater 2 (62.26%. Conclusions: The processes of translation and cross-cultural adaptation were conducted on the REBA instrument and the Brazilian version of the instrument was obtained. However, despite the reliability of the tests used to correct the translated and adapted version, the reliability values are unacceptable according to the guidelines standard, indicating that the reliability must be re-evaluated. Therefore, caution in the interpretation of the biomechanical risks measured by this instrument should be taken.

  14. Translation, cross-cultural adaptation to Brazilian- Portuguese and reliability analysis of the instrument Rapid Entire Body Assessment-REBA

    Science.gov (United States)

    Lamarão, Andressa M.; Costa, Lucíola C. M.; Comper, Maria L. C.; Padula, Rosimeire S.

    2014-01-01

    Background: Observational instruments, such as the Rapid Entire Body Assessment, quickly assess biomechanical risks present in the workplace. However, in order to use these instruments, it is necessary to conduct the translational/cross-cultural adaptation of the instrument and test its measurement properties. Objectives: To perform the translation and the cross-cultural adaptation to Brazilian-Portuguese and test the reliability of the REBA instrument. Method: The procedures of translation and cross-cultural adaptation to Brazilian-Portuguese were conducted following proposed guidelines that involved translation, synthesis of translations, back translation, committee review and testing of the pre-final version. In addition, reliability and the intra- and inter-rater percent agreement were obtained with the Linear Weighted Kappa Coefficient that was associated with the 95% Confidence Interval and the cross tabulation 2×2. Results : The procedures for translation and adaptation were adequate and the necessary adjustments were conducted on the instrument. The intra- and inter-rater reliability showed values of 0.104 to 0.504, respectively, ranging from very poor to moderate. The percentage agreement values ranged from 5.66% to 69.81%. The percentage agreement was closer to 100% at the item 'upper arm' (69.81%) for the Intra-rater 1 and at the items 'legs' and 'upper arm' for the Intra-rater 2 (62.26%). Conclusions: The processes of translation and cross-cultural adaptation were conducted on the REBA instrument and the Brazilian version of the instrument was obtained. However, despite the reliability of the tests used to correct the translated and adapted version, the reliability values are unacceptable according to the guidelines standard, indicating that the reliability must be re-evaluated. Therefore, caution in the interpretation of the biomechanical risks measured by this instrument should be taken. PMID:25003273

  15. Development of Highly Reliable Power and Communication System for Essential Instruments Under Severe Accidents in NPP

    Directory of Open Access Journals (Sweden)

    Bo Hwan Choi

    2016-10-01

    Full Text Available This article proposes a highly reliable power and communication system that guarantees the protection of essential instruments in a nuclear power plant under a severe accident. Both power and communication lines are established with not only conventional wired channels, but also the proposed wireless channels for emergency reserve. An inductive power transfer system is selected due to its robust power transfer characteristics under high temperature, high pressure, and highly humid environments with a large amount of scattered debris after a severe accident. A thermal insulation box and a glass-fiber reinforced plastic box are proposed to protect the essential instruments, including vulnerable electronic circuits, from extremely high temperatures of up to 627°C and pressure of up to 5 bar. The proposed wireless power and communication system is experimentally verified by an inductive power transfer system prototype having a dipole coil structure and prototype Zigbee modules over a 7-m distance, where both the thermal insulation box and the glass-fiber reinforced plastic box are fabricated and tested using a high-temperature chamber. Moreover, an experiment on the effects of a high radiation environment on various electronic devices is conducted based on the radiation test having a maximum accumulated dose of 27 Mrad.

  16. Development of highly reliable power and communication system for essential instruments under severe accidents in NPP

    International Nuclear Information System (INIS)

    Choi, Bo Hwan; Jang, Gi Chan; Shin, Sung Min; Kang, Hyun Gook; Rim, Chun Taek; Lee, Soo Ill

    2016-01-01

    This article proposes a highly reliable power and communication system that guarantees the protection of essential instruments in a nuclear power plant under a severe accident. Both power and communication lines are established with not only conventional wired channels, but also the proposed wireless channels for emergency reserve. An inductive power transfer system is selected due to its robust power transfer characteristics under high temperature, high pressure, and highly humid environments with a large amount of scattered debris after a severe accident. A thermal insulation box and a glass-fiber reinforced plastic box are proposed to protect the essential instruments, including vulnerable electronic circuits, from extremely high temperatures of up to 627 .deg. C and pressure of up to 5 bar. The proposed wireless power and communication system is experimentally verified by an inductive power transfer system prototype having a dipole coil structure and prototype Zigbee modules over a 7-m distance, where both the thermal insulation box and the glass-fiber reinforced plastic box are fabricated and tested using a high-temperature chamber. Moreover, an experiment on the effects of a high radiation environment on various electronic devices is conducted based on the radiation test having a maximum accumulated dose of 27 Mrad

  17. Development of highly reliable power and communication system for essential instruments under severe accidents in NPP

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Bo Hwan; Jang, Gi Chan; Shin, Sung Min; Kang, Hyun Gook; Rim, Chun Taek [Dept. of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Lee, Soo Ill [I and C Group, Korea Hydro and Nuclear Power Co., Ltd, Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    This article proposes a highly reliable power and communication system that guarantees the protection of essential instruments in a nuclear power plant under a severe accident. Both power and communication lines are established with not only conventional wired channels, but also the proposed wireless channels for emergency reserve. An inductive power transfer system is selected due to its robust power transfer characteristics under high temperature, high pressure, and highly humid environments with a large amount of scattered debris after a severe accident. A thermal insulation box and a glass-fiber reinforced plastic box are proposed to protect the essential instruments, including vulnerable electronic circuits, from extremely high temperatures of up to 627 .deg. C and pressure of up to 5 bar. The proposed wireless power and communication system is experimentally verified by an inductive power transfer system prototype having a dipole coil structure and prototype Zigbee modules over a 7-m distance, where both the thermal insulation box and the glass-fiber reinforced plastic box are fabricated and tested using a high-temperature chamber. Moreover, an experiment on the effects of a high radiation environment on various electronic devices is conducted based on the radiation test having a maximum accumulated dose of 27 Mrad.

  18. Soft computing approach for reliability optimization: State-of-the-art survey

    International Nuclear Information System (INIS)

    Gen, Mitsuo; Yun, Young Su

    2006-01-01

    In the broadest sense, reliability is a measure of performance of systems. As systems have grown more complex, the consequences of their unreliable behavior have become severe in terms of cost, effort, lives, etc., and the interest in assessing system reliability and the need for improving the reliability of products and systems have become very important. Most solution methods for reliability optimization assume that systems have redundancy components in series and/or parallel systems and alternative designs are available. Reliability optimization problems concentrate on optimal allocation of redundancy components and optimal selection of alternative designs to meet system requirement. In the past two decades, numerous reliability optimization techniques have been proposed. Generally, these techniques can be classified as linear programming, dynamic programming, integer programming, geometric programming, heuristic method, Lagrangean multiplier method and so on. A Genetic Algorithm (GA), as a soft computing approach, is a powerful tool for solving various reliability optimization problems. In this paper, we briefly survey GA-based approach for various reliability optimization problems, such as reliability optimization of redundant system, reliability optimization with alternative design, reliability optimization with time-dependent reliability, reliability optimization with interval coefficients, bicriteria reliability optimization, and reliability optimization with fuzzy goals. We also introduce the hybrid approaches for combining GA with fuzzy logic, neural network and other conventional search techniques. Finally, we have some experiments with an example of various reliability optimization problems using hybrid GA approach

  19. Development of the Human Factors Skills for Healthcare Instrument: a valid and reliable tool for assessing interprofessional learning across healthcare practice settings.

    Science.gov (United States)

    Reedy, Gabriel B; Lavelle, Mary; Simpson, Thomas; Anderson, Janet E

    2017-10-01

    A central feature of clinical simulation training is human factors skills, providing staff with the social and cognitive skills to cope with demanding clinical situations. Although these skills are critical to safe patient care, assessing their learning is challenging. This study aimed to develop, pilot and evaluate a valid and reliable structured instrument to assess human factors skills, which can be used pre- and post-simulation training, and is relevant across a range of healthcare professions. Through consultation with a multi-professional expert group, we developed and piloted a 39-item survey with 272 healthcare professionals attending training courses across two large simulation centres in London, one specialising in acute care and one in mental health, both serving healthcare professionals working across acute and community settings. Following psychometric evaluation, the final 12-item instrument was evaluated with a second sample of 711 trainees. Exploratory factor analysis revealed a 12-item, one-factor solution with good internal consistency (α=0.92). The instrument had discriminant validity, with newly qualified trainees scoring significantly lower than experienced trainees ( t (98)=4.88, pSkills for Healthcare Instrument provides a reliable and valid method of assessing trainees' human factors skills self-efficacy across acute and mental health settings. This instrument has the potential to improve the assessment and evaluation of human factors skills learning in both uniprofessional and interprofessional clinical simulation training.

  20. Validity and reliability of a pictorial instrument for assessing perceived motor competence in Portuguese children.

    Science.gov (United States)

    Lopes, V P; Barnett, L M; Saraiva, L; Gonçalves, C; Bowe, S J; Abbott, G; Rodrigues, L P

    2016-09-01

    It is important to assess young children's perceived Fundamental Movement Skill (FMS) competence in order to examine the role of perceived FMS competence in motivation toward physical activity. Children's perceptions of motor competence may vary according to the culture/country of origin; therefore, it is also important to measure perceptions in different cultural contexts. The purpose was to assess the face validity, internal consistency, test-retest reliability and construct validity of the 12 FMS items in the Pictorial Scale for Perceived Movement Skill Competence for Young Children (PMSC) in a Portuguese sample. Two hundred one Portuguese children (girls, n = 112), 5 to 10 years of age (7.6 ± 1.4), participated. All children completed the PMSC once. Ordinal alpha assessed internal consistency. A random subsamples (n = 47) were reassessed one week later to determine test-retest reliability with Bland-Altman method. Children were asked questions after the second administration to determine face validity. Construct validity was assessed on the whole sample with a Bayesian Structural Equation Modelling (BSEM) approach. The hypothesized theoretical model used the 12 items and two hypothesized factors: object control and locomotor skills. The majority of children correctly identified the skills and could understand most of the pictures. Test-retest reliability analysis was good, with an agreement ration between 0.99 and 1.02. Ordinal alpha values ranged from acceptable (object control 0.73, locomotor 0.68) to good (all FMS 0.81). The hypothesized BSEM model had an adequate fit. The PMSC can be used to investigate perceptions of children's FMS competence. This instrument can also be satisfactorily used among Portuguese children. © 2016 John Wiley & Sons Ltd.

  1. New-generation low-power radiation survey instruments

    International Nuclear Information System (INIS)

    Waechter, D.A.; Bjarke, G.O.; Wolf, M.A.; Trujillo, F.; Umbarger, C.J.

    1983-01-01

    A number of new, ultra-low-powered radiation instruments have recently been developed at Los Alamos. Among these are two instruments which use a novel power source to eliminate costly batteries. The newly developed gamma detecting radiac, nicknamed the Firefly, and the alpha particle detecting instrument, called the Simple Cordless Alpha Monitor, both use recent advances in miniaturization and power-saving electronics to yield devices which are small, rugged, and very power-frugal. The two instruments consume so little power that the need for batteries to run them is eliminated. They are, instead, powered by a charged capacitor which will operate the instruments for an hour or more. Both line power and mechanical sources are used to charge the storage capacitors which power the instruments

  2. Reliability and Validity of Modified Service Quality Instrument (SERVQUAL) in Patients' Motivation to Adhere to Insulin Therapy.

    Science.gov (United States)

    Jakupovic, Vedran; Solakovic, Suajb; Celebic, Nedim; Kulovic, Dzenan

    2018-03-01

    Diabetes is progressive condition which requires various ways of treatment. Adequate therapy prescribed in the right time helps patient to postpone development of complications. Adherence to complicated therapy is challenge for both patients and HCPs and is subject of research in many disciplines. Improvement in communication between HCP and patients is very important in patient's adherence to therapy. Aim of this research was to explore validity and reliability of modified SERVQUAL instrument in attempt to explore ways of motivating diabetic patient to accept prescribed insulin therapy. We used modified SERVQUAL questionnaire as instrument in the research. It was necessary to check validity and reliability of the new modified instrument. Results show that modified Servqual instrument has excellent reliability (α=0.908), so we could say that it measures precisely Expectations, Perceptions and Motivation at patients. Factor analysis (EFA method) with Varimax rotation extracted 4 factors which together explain 52.902% variance of the results on this subscale. Bifactorial solution could be seen on Scree-plot diagram (break at second factor). Results in this research show that modified Servqual instrument which is created in order to measure expectations and perceptions of the patients is valid and reliable. Reliability and validity are proven indeed in additional dimension which was created originally for this research - motivation to accept insulin therapy.

  3. Reliability and Validity of Modified Service Quality Instrument (SERVQUAL) in Patients’ Motivation to Adhere to Insulin Therapy

    Science.gov (United States)

    Jakupovic, Vedran; Solakovic, Suajb; Celebic, Nedim; Kulovic, Dzenan

    2018-01-01

    Introduction: Diabetes is progressive condition which requires various ways of treatment. Adequate therapy prescribed in the right time helps patient to postpone development of complications. Adherence to complicated therapy is challenge for both patients and HCPs and is subject of research in many disciplines. Improvement in communication between HCP and patients is very important in patient’s adherence to therapy. Aim: Aim of this research was to explore validity and reliability of modified SERVQUAL instrument in attempt to explore ways of motivating diabetic patient to accept prescribed insulin therapy. Material and Methods: We used modified SERVQUAL questionnaire as instrument in the research. It was necessary to check validity and reliability of the new modified instrument. Results: Results show that modified Servqual instrument has excellent reliability (α=0.908), so we could say that it measures precisely Expectations, Perceptions and Motivation at patients. Factor analysis (EFA method) with Varimax rotation extracted 4 factors which together explain 52.902% variance of the results on this subscale. Bifactorial solution could be seen on Scree-plot diagram (break at second factor). Conclusion: Results in this research show that modified Servqual instrument which is created in order to measure expectations and perceptions of the patients is valid and reliable. Reliability and validity are proven indeed in additional dimension which was created originally for this research - motivation to accept insulin therapy. PMID:29670478

  4. An Interactive Whiteboard Student Survey: Development, Validity and Reliability

    Science.gov (United States)

    Turel, Yalin Kilic

    2011-01-01

    The interactive whiteboard (IWB) has become a popular technology for instructors over the last decade. Though research asserts that the IWBs facilitate learning in different ways, there is a lack of studies examining actual IWB use in classroom settings based on learners' perspectives by means of valid instruments. The purpose of this study is to…

  5. A Survey of Software Reliability Modeling and Estimation

    Science.gov (United States)

    1983-09-01

    considered include: the Jelinski-Moranda Model, the ,Geometric Model,’ and Musa’s Model. A Monte -Carlo study of the behavior of the ’V"’"*least squares...ceedings Number 261, 1979, pp. 34-1, 34-11. IoelAmrit, AGieboSSukert, Alan and Goel, Ararat , "A Guidebookfor Software Reliability Assessment, 1980

  6. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    Energy Technology Data Exchange (ETDEWEB)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides. (JGB)

  7. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    International Nuclear Information System (INIS)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides

  8. Practical guidelines for developing a smartphone-based survey instrument

    DEFF Research Database (Denmark)

    Ohme, Jakob; de Vreese, Claes Holger; Albæk, Erik

    The increasing relevance of mobile surveys makes it important to gather empirical evidence on designs of such surveys. This research note presents the results of a test study conducted to identify the best set-up for a smartphone-based survey. We base our analysis on a random sample of Danish...

  9. A technical survey on issues of the quantitative evaluation of software reliability

    International Nuclear Information System (INIS)

    Park, J. K; Sung, T. Y.; Eom, H. S.; Jeong, H. S.; Park, J. H.; Kang, H. G.; Lee, K. Y.; Park, J. K.

    2000-04-01

    To develop the methodology for evaluating the software reliability included in digital instrumentation and control system (I and C), many kinds of methodologies/techniques that have been proposed from the software reliability engineering fuel are analyzed to identify the strong and week points of them. According to analysis results, methodologies/techniques that can be directly applied for the evaluation of the software reliability are not exist. Thus additional researches to combine the most appropriate methodologies/techniques from existing ones would be needed to evaluate the software reliability. (author)

  10. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  11. Survey of methods used to asses human reliability in the human factors reliability benchmark exercise

    International Nuclear Information System (INIS)

    Poucet, A.

    1988-01-01

    The Joint Research Centre of the European Commission has organised a Human Factors Reliability Benchmark Exercise (HF-RBE) with the aim to assess the state-of-the-art in human reliability modelling and assessment. Fifteen teams from eleven countries, representing industry, utilities, licensing organisations and research institutes, participate in the HF-RBE, which is organised around two study cases: (1) analysis of routine functional test and maintenance procedures, with the aim to assess the probability of test-induced failures, the probability of failures to remain unrevealed, and the potential to initiate transients because of errors performed in the test; and (2) analysis of human actions during an operational transient, with the aim to assess the probability that the operators will correctly diagnose the malfunctions and take proper corrective action. The paper briefly reports how the HF-RBE was structured and gives an overview of the methods that have been used for predicting human reliability in both study cases. The experience in applying these methods is discussed and the results obtained are compared. (author)

  12. Reliability of a retail food store survey and development of an accompanying retail scoring system to communicate survey findings and identify vendors for healthful food and marketing initiatives.

    Science.gov (United States)

    Ghirardelli, Alyssa; Quinn, Valerie; Sugerman, Sharon

    2011-01-01

    To develop a retail grocery instrument with weighted scoring to be used as an indicator of the food environment. Twenty six retail food stores in low-income areas in California. Observational. Inter-rater reliability for grocery store survey instrument. Description of store scoring methodology weighted to emphasize availability of healthful food. Type A intra-class correlation coefficients (ICC) with absolute agreement definition or a κ test for measures using ranges as categories. Measures of availability and price of fruits and vegetables performed well in reliability testing (κ = 0.681-0.800). Items for vegetable quality were better than for fruit (ICC 0.708 vs 0.528). Kappa scores indicated low to moderate agreement (0.372-0.674) on external store marketing measures and higher scores for internal store marketing. "Next to" the checkout counter was more reliable than "within 6 feet." Health departments using the store scoring system reported it as the most useful communication of neighborhood findings. There was good reliability of the measures among the research pairs. The local store scores can show the need to bring in resources and to provide access to fruits and vegetables and other healthful food. Copyright © 2011 Society for Nutrition Education. Published by Elsevier Inc. All rights reserved.

  13. Validity and reliability of a new instrument for the evaluation of dental collaboration in disabled people

    Directory of Open Access Journals (Sweden)

    Scilla Sparabombe

    2013-10-01

    Full Text Available Background: nowadays, oral health in people with disabilities is an important topic. The phsychological and behavioural problems of these people, their difficulties with environmental adaptations and the absence of any traditional communication determine the compliance needed for treatment The aim of this work was to test the validity and reliability of an original questionnaire that could become an instrument assessing the individual features in people with mental retardation and other developmental disabilities at the time of dental treatment.Methods: it was created a questionnaire with standardised answers regarding four specific areas: neuropsychology, emotional-affect, autonomy and environmental resources. The questionnaire was completed by 63 patients from three different institutes (two rehabilitation institutes and an Institute of Dentistry for patients with special needs. To analyse the answers, each item was transformed into a numeric value. A value of 1 was displayed as the minimum while 4 represented full possession of the considered skills. A total of 17 variables were analysed with descriptive statistics and multivariate analysis. Internal consistency reliability was measured using Cronbach’s alpha. Furthermore, an analysis on convergent/discriminant validity was provided.Results: all variables were positively correlated. The most significant were “guidance”, “communication”, “sociability”, “view”, “hearing” and “feeding”. Items like “self-control”, “equanimity”, “problematic behaviour”, “extroversion” and “autonomy” offered vague and less significant information in identifying the patient’s collaboration level. Variables like “evaluation by the compiler about the patient’s collaboration”, “previous dental experiences” and “attendant” were confirmed. Cronbach’s alpha was 0.77 (standardized result, which meet the a priori criterion of 0.90≥alpha≥0.70.Conclusions

  14. The validity and reliability of the Socioeconomic Status Instrument for assessing prostate cancer patients.

    Science.gov (United States)

    Cyrus-David, Mfon

    2010-08-01

    Because of the lack of consistency in the associations of the socioeconomic status (SES) of prostate cancer (PC) patients from diverse racial and ethnic backgrounds with PC health outcomes, I created the Socioeconomic Status Instrument (SESI) from the Demographic and Health Access components of the Behavioral Risk Factor Surveillance System 2004 Questionnaires and the socioeconomic indices of the subjects' residential counties to better assess the SES of PC patients. The SESI was tested on 220 consecutive subjects with pathologically confirmed PC at the Veterans Affairs Medical Center in Houston, TX. A team that included an epidemiologist, a validation statistician/health services research scientist, and PC survivors assessed the content validity of the SESI. The construct validity of the SESI was assessed with factor analysis by extracting and analyzing 5 principal components based on the subjects' individual responses on the assessment: county socioeconomic characteristics, individual socioeconomic characteristics, financial distress, increased domestic burden with limited earnings, and affluence. The internal consistency reliability of the SESI was assessed with Cronbach's alpha coefficients. Based on the reviews of the SESI, all of the initial 10 items were retained. The correlations between individual responses on the SESI were similar to the results of previous studies. The 5 principal components that I assessed accounted for 71.5% of the variance. Factor loadings ranged from 0.66 to 0.98 and communalities ranged from 0.55 to 0.94. County socioeconomic characteristics accounted for 22.6% of the variance, whereas individual socioeconomic characteristics accounted for 14.6% of the variance. The overall Cronbach's alpha coefficient was 0.78. The SESI is valid and reliable. Accurate measurements of the SES of PC patients would provide better guidance for future research and care deliveries.

  15. Integrating software reliability concepts into risk and reliability modeling of digital instrumentation and control systems used in nuclear power plants

    International Nuclear Information System (INIS)

    Arndt, S. A.

    2006-01-01

    As software-based digital systems are becoming more and more common in all aspects of industrial process control, including the nuclear power industry, it is vital that the current state of the art in quality, reliability, and safety analysis be advanced to support the quantitative review of these systems. Several research groups throughout the world are working on the development and assessment of software-based digital system reliability methods and their applications in the nuclear power, aerospace, transportation, and defense industries. However, these groups are hampered by the fact that software experts and probabilistic safety assessment experts view reliability engineering very differently. This paper discusses the characteristics of a common vocabulary and modeling framework. (authors)

  16. International Energy Agency instrumented facilities survey for solar assisted low energy dwellings

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-02-01

    Compiled are surveys outlining the instrumentation of 38 active and passive solar projects in 9 countries (Denmark, Italy, Japan, Netherlands, Sweden, Switzerland, United Kingdom, United States, and West Germany). After the surveys themselves are presented, the data are rearranged to compare answers from similar survey questions for each of the projects. These questions address building, solar system and instrumentation descriptions and meteorological, solar system and building system instrumentatation capabilities. (LEW)

  17. A Reliable and Valid Survey to Predict a Patient’s Gagging Intensity

    Directory of Open Access Journals (Sweden)

    Casey M. Hearing

    2014-07-01

    Full Text Available Objectives: The aim of this study was to devise a reliable and valid survey to predict the intensity of someone’s gag reflex. Material and Methods: A 10-question Predictive Gagging Survey was created, refined, and tested on 59 undergraduate participants. The questions focused on risk factors and experiences that would indicate the presence and strength of someone’s gag reflex. Reliability was assessed by administering the survey to a group of 17 participants twice, with 3 weeks separating the two administrations. Finally, the survey was given to 25 dental patients. In these cases, patients completed an informed consent form, filled out the survey, and then had a maxillary impression taken while their gagging response was quantified from 1 to 5 on the Fiske and Dickinson Gagging Intensity Index. Results: There was a moderate positive correlation between the Predictive Gagging Survey and Fiske and Dickinson’s Gagging Severity Index, r = +0.64, demonstrating the survey’s validity. Furthermore, the test-retest reliability was r = +0.96, demonstrating the survey’s reliability. Conclusions: The Predictive Gagging Survey is a 10-question survey about gag-related experiences and behaviours. We established that it is a reliable and valid method to assess the strength of someone’s gag reflex.

  18. Assessing the Learning Environment for Medical Students: An Evaluation of a Novel Survey Instrument in Four Medical Schools.

    Science.gov (United States)

    Pololi, Linda H; Evans, Arthur T; Nickell, Leslie; Reboli, Annette C; Coplit, Lisa D; Stuber, Margaret L; Vasiliou, Vasilia; Civian, Janet T; Brennan, Robert T

    2017-06-01

    A practical, reliable, and valid instrument is needed to measure the impact of the learning environment on medical students' well-being and educational experience and to meet medical school accreditation requirements. From 2012 to 2015, medical students were surveyed at the end of their first, second, and third year of studies at four medical schools. The survey assessed students' perceptions of the following nine dimensions of the school culture: vitality, self-efficacy, institutional support, relationships/inclusion, values alignment, ethical/moral distress, work-life integration, gender equity, and ethnic minority equity. The internal reliability of each of the nine dimensions was measured. Construct validity was evaluated by assessing relationships predicted by our conceptual model and prior research. Assessment was made of whether the measurements were sensitive to differences over time and across institutions. Six hundred and eighty-six students completed the survey (49 % women; 9 % underrepresented minorities), with a response rate of 89 % (range over the student cohorts 72-100 %). Internal consistency of each dimension was high (Cronbach's α 0.71-0.86). The instrument was able to detect significant differences in the learning environment across institutions and over time. Construct validity was supported by demonstrating several relationships predicted by our conceptual model. The C-Change Medical Student Survey is a practical, reliable, and valid instrument for assessing the learning environment of medical students. Because it is sensitive to changes over time and differences across institution, results could potentially be used to facilitate and monitor improvements in the learning environment of medical students.

  19. Virtualization of Legacy Instrumentation Control Computers for Improved Reliability, Operational Life, and Management.

    Science.gov (United States)

    Katz, Jonathan E

    2017-01-01

    Laboratories tend to be amenable environments for long-term reliable operation of scientific measurement equipment. Indeed, it is not uncommon to find equipment 5, 10, or even 20+ years old still being routinely used in labs. Unfortunately, the Achilles heel for many of these devices is the control/data acquisition computer. Often these computers run older operating systems (e.g., Windows XP) and, while they might only use standard network, USB or serial ports, they require proprietary software to be installed. Even if the original installation disks can be found, it is a burdensome process to reinstall and is fraught with "gotchas" that can derail the process-lost license keys, incompatible hardware, forgotten configuration settings, etc. If you have running legacy instrumentation, the computer is the ticking time bomb waiting to put a halt to your operation.In this chapter, I describe how to virtualize your currently running control computer. This virtualized computer "image" is easy to maintain, easy to back up and easy to redeploy. I have used this multiple times in my own lab to greatly improve the robustness of my legacy devices.After completing the steps in this chapter, you will have your original control computer as well as a virtual instance of that computer with all the software installed ready to control your hardware should your original computer ever be decommissioned.

  20. Measuring teamwork in health care settings: a review of survey instruments.

    Science.gov (United States)

    Valentine, Melissa A; Nembhard, Ingrid M; Edmondson, Amy C

    2015-04-01

    Teamwork in health care settings is widely recognized as an important factor in providing high-quality patient care. However, the behaviors that comprise effective teamwork, the organizational factors that support teamwork, and the relationship between teamwork and patient outcomes remain empirical questions in need of rigorous study. To identify and review survey instruments used to assess dimensions of teamwork so as to facilitate high-quality research on this topic. We conducted a systematic review of articles published before September 2012 to identify survey instruments used to measure teamwork and to assess their conceptual content, psychometric validity, and relationships to outcomes of interest. We searched the ISI Web of Knowledge database, and identified relevant articles using the search terms team, teamwork, or collaboration in combination with survey, scale, measure, or questionnaire. We found 39 surveys that measured teamwork. Surveys assessed different dimensions of teamwork. The most commonly assessed dimensions were communication, coordination, and respect. Of the 39 surveys, 10 met all of the criteria for psychometric validity, and 14 showed significant relationships to nonself-report outcomes. Evidence of psychometric validity is lacking for many teamwork survey instruments. However, several psychometrically valid instruments are available. Researchers aiming to advance research on teamwork in health care should consider using or adapting one of these instruments before creating a new one. Because instruments vary considerably in the behavioral processes and emergent states of teamwork that they capture, researchers must carefully evaluate the conceptual consistency between instrument, research question, and context.

  1. Validity and reliability of a nutrition knowledge survey for assessment in elementary school children.

    Science.gov (United States)

    Gower, Jared R; Moyer-Mileur, Laurie J; Wilkinson, Robert D; Slater, Hillarie; Jordan, Kristine C

    2010-03-01

    Limited surveys are available to assess the nutrition knowledge of children. The goals of this study were to test the validity and reliability of a computer nutrition knowledge survey for elementary school students and to evaluate the impact of the "Fit Kids 'r' Healthy Kids" nutrition intervention via the knowledge survey. During survey development, a sample (n=12) of health educators, elementary school teachers, and registered dietitians assessed the survey. The target population consisted of first- through fourth-grade students from Salt Lake City, UT, metropolitan area schools. Participants were divided into reliability (n=68), intervention (n=74), and control groups (n=59). The reliability group took the survey twice (2 weeks apart); the intervention and control groups also took the survey twice, but at pre- and post-intervention (4 weeks later). Only students from the intervention group participated in four weekly nutrition classes. Reliability was assessed by Pearson's correlation coefficients for knowledge scores. Results demonstrated appropriate content validity, as indicated by expert peer ratings. Test-retest reliability correlations were found to be significant for the overall survey (r=0.54; PNutrition knowledge was assessed upon program completion with paired samples t tests. Students from the intervention group demonstrated improvement in nutrition knowledge (12.2+/-1.9 to 13.5+/-1.6; Pnutrition survey demonstrated content validity and test-retest reliability for first- through fourth-grade elementary school children. Also, the study results imply that the Fit Kids 'r' Healthy Kids intervention promoted gains in nutrition knowledge. Overall, the computer survey shows promise as an appealing medium for assessing nutrition knowledge in children. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  2. Test-retest Reliability and Agreement of the Satisfaction with the Assistive Technology Services (SATS) Instrument in Two Nordic Countries

    DEFF Research Database (Denmark)

    Sund, Terje; Anttila, Heidi; Iwarsson, Susanne

    2014-01-01

    Purpose: The purpose of this study was to investigate test–retest reliability, agreement, internal consistency, and floor- and ceiling effects of the Danish and Finnish versions of the Satisfaction with the Assistive Technology Services (SATS) instrument among adult users of powered wheelchairs (...

  3. Designing, Testing, and Validating an Attitudinal Survey on an Environmental Topic: A Groundwater Pollution Survey Instrument for Secondary School Students

    Science.gov (United States)

    Lacosta-Gabari, Idoya; Fernandez-Manzanal, Rosario; Sanchez-Gonzalez, Dolores

    2009-01-01

    Research in environmental attitudes' assessment has significantly increased in recent years. The development of specific attitude scales for specific environmental problems has often been proposed. This paper describes the Groundwater Pollution Test (GPT), a 19-item survey instrument using a Likert-type scale. The survey has been used with…

  4. A survey on reliability and safety analysis techniques of robot systems in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Eom, H S; Kim, J H; Lee, J C; Choi, Y R; Moon, S S

    2000-12-01

    The reliability and safety analysis techniques was surveyed for the purpose of overall quality improvement of reactor inspection system which is under development in our current project. The contents of this report are : 1. Reliability and safety analysis techniques suvey - Reviewed reliability and safety analysis techniques are generally accepted techniques in many industries including nuclear industry. And we selected a few techniques which are suitable for our robot system. They are falut tree analysis, failure mode and effect analysis, reliability block diagram, markov model, combinational method, and simulation method. 2. Survey on the characteristics of robot systems which are distinguished from other systems and which are important to the analysis. 3. Survey on the nuclear environmental factors which affect the reliability and safety analysis of robot system 4. Collection of the case studies of robot reliability and safety analysis which are performed in foreign countries. The analysis results of this survey will be applied to the improvement of reliability and safety of our robot system and also will be used for the formal qualification and certification of our reactor inspection system.

  5. A survey on reliability and safety analysis techniques of robot systems in nuclear power plants

    International Nuclear Information System (INIS)

    Eom, H.S.; Kim, J.H.; Lee, J.C.; Choi, Y.R.; Moon, S.S.

    2000-12-01

    The reliability and safety analysis techniques was surveyed for the purpose of overall quality improvement of reactor inspection system which is under development in our current project. The contents of this report are : 1. Reliability and safety analysis techniques suvey - Reviewed reliability and safety analysis techniques are generally accepted techniques in many industries including nuclear industry. And we selected a few techniques which are suitable for our robot system. They are falut tree analysis, failure mode and effect analysis, reliability block diagram, markov model, combinational method, and simulation method. 2. Survey on the characteristics of robot systems which are distinguished from other systems and which are important to the analysis. 3. Survey on the nuclear environmental factors which affect the reliability and safety analysis of robot system 4. Collection of the case studies of robot reliability and safety analysis which are performed in foreign countries. The analysis results of this survey will be applied to the improvement of reliability and safety of our robot system and also will be used for the formal qualification and certification of our reactor inspection system

  6. Psychometric Analysis and Qualitative Review of an Outpatient Radiology-Specific Patient Satisfaction Survey: A Call for Collaboration in Validating a Survey Instrument.

    Science.gov (United States)

    Dibble, Elizabeth H; Baird, Grayson L; Swenson, David W; Healey, Terrance T

    2017-10-01

    The aim of this study was to perform a psychometric analysis of the constructs and reliability of an outpatient radiology-specific patient satisfaction survey and identify factors that drive patient experience so that radiology practices can improve the quality of their diagnostic imaging services. This retrospective study examined responses to eight patient satisfaction questions from a survey originally developed by a nascent marketing team and then administered at five outpatient imaging centers from January 7, 2013, to November 11, 2015. Patients' responses were reviewed to identify factors that affected patient experience, and a psychometric analysis of the survey instrument itself was performed, including exploratory factor analyses and reliability testing. Patient responses were compared among sites, examination types, and questions. Free-text comments were qualitatively categorized and compared by examination type. In total, 6,512 surveys were completed among 137,059 patient encounters. Using exploratory factor analyses of the eight survey questions, three relevant patient experience constructs were derived: (1) front office experience, (2) intake experience, and (3) examination experience. Overall, good scale reliability was observed. Perceived quality of care had the most positive ratings; wait time had the most nonpositive ratings. Of 2,024 free-text comments, 1,859 were positive (most pertaining to staff), and 155 were negative (most pertaining to convenience). MRI patients were most likely to share negative comments, typically regarding the examination experience itself. Psychometric analysis of a patient survey derived three core patient experience constructs: front office experience, intake experience, and examination experience. The survey indicates the need to decrease wait times, streamline the registration process, and improve patient comfort during MRI examinations. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All

  7. Product analysis and initial reliability testing of the total mesorectal excision-quality assessment instrument.

    Science.gov (United States)

    Simunovic, Marko R; DeNardi, Franco G; Coates, Angela J; Szalay, David A; Eva, Kevin W

    2014-07-01

    Product analysis of rectal cancer resection specimens before specimen fixation may provide an immediate and relevant evaluation of surgical performance. We tested the interrater reliability (IRR) of a product analysis tool called the Total Mesorectal Excision-Quality Assessment Instrument (TME-QA). Participants included two gold standard raters, five pathology assistants, and eight pathologists. Domains of the TME-QA reflect total mesorectal excision principles including: (1) completeness of mesorectal margin; (2) completeness of mesorectum; (3) coning of distal mesorectum; (4) physical defects; and (5) overall specimen quality. Specimens were scored independently. We used the generalizability theory to assess the tool's internal consistency and IRR. There were 39 specimens and 120 ratings. Mean overall specimen quality scores for the gold standard raters, pathologists, and assistants were 4.43, 4.43, and 4.50, respectively (p > 0.85). IRR for the first nine items was 0.68 for the full sample, 0.62 for assistants alone, 0.63 for pathologists alone, and 0.74 for gold standard raters alone. IRR for the item overall specimen quality was 0.67 for the full sample, 0.45 for assistants, 0.80 for pathologists, and 0.86 for gold standard raters. IRR increased for all groups when scores were averaged across two raters. Assessment of surgical specimens using the TME-QA may provide rapid and relevant feedback to surgeons about their technical performance. Our results show good internal consistency and IRR when the TME-QA is used by pathologists. However, for pathology assistants, multiple ratings with the averaging of scores may be needed.

  8. John F. Kennedy Space Center, Safety, Reliability, Maintainability and Quality Assurance, Survey and Audit Program

    Science.gov (United States)

    1994-01-01

    This document is the product of the KSC Survey and Audit Working Group composed of civil service and contractor Safety, Reliability, and Quality Assurance (SR&QA) personnel. The program described herein provides standardized terminology, uniformity of survey and audit operations, and emphasizes process assessments rather than a program based solely on compliance. The program establishes minimum training requirements, adopts an auditor certification methodology, and includes survey and audit metrics for the audited organizations as well as the auditing organization.

  9. Satisfactory reliability among nursing students using the instrument PVC ASSESS to evaluate management of peripheral venous catheters.

    Science.gov (United States)

    Ahlqvist, Margary; Berglund, Britta; Nordström, Gun; Klang, Birgitta; Johansson, Eva

    2014-01-01

    Nursing students should be given opportunities to participate in clinical audits during their education. However, audit tools are seldom tested for reliability among nursing students. The aim of this study was to present reliability among nursing students using the instrument PVC assess to assess management of peripheral venous catheters (PVCs) and PVC-related signs of thrombophlebitis. PVC assess was used to assess 67 inserted PVCs in 60 patients at ten wards at a university hospital. One group of nursing students (n=4) assessed PVCs at the bedside (inter-rater reliability) and photographs of these PVCs were taken. Another group of students (n=3) assessed the PVCs in the photographs after 4 weeks (test-retest reliability). To determine reliability, proportion of agreement [P(A)] and Cohen's kappa coefficient (κ) were calculated. For bedside assessment of PVCs, P(A) ranged from good to excellent (0.80-1.0) in 55% of the 26 PVC assess items that were tested. P(A) was poor (satisfactory reliability among nursing students. However, students need training in how to use the instrument before assessing PVCs.

  10. A Systematic Review of Statistical Methods Used to Test for Reliability of Medical Instruments Measuring Continuous Variables

    Directory of Open Access Journals (Sweden)

    Rafdzah Zaki

    2013-06-01

    Full Text Available   Objective(s: Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice.   Materials and Methods: In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. Results: The Intra-class Correlation Coefficient (ICC is the most popular method with 25 (60% studies having used this method followed by the comparing means (8 or 19%. Out of 25 studies using the ICC, only 7 (28% reported the confidence intervals and types of ICC used. Most studies (71% also tested the agreement of instruments. Conclusion: This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  11. Thai SF-36 health survey: tests of data quality, scaling assumptions, reliability and validity in healthy men and women.

    Science.gov (United States)

    Lim, Lynette L-Y; Seubsman, Sam-Ang; Sleigh, Adrian

    2008-07-18

    Since its translation to Thai in 2000, the SF-36 Health Survey has been used extensively in many different clinical settings in Thailand. Its popularity has increased despite the absence of published evidence that the translated instrument satisfies scoring assumptions, the psychometric properties required for valid interpretation of the SF-36 summated ratings scales. The purpose of this paper was to examine these properties and to report on the reliability and validity of the Thai SF-36 in a non-clinical general population. 1345 distance-education university students who live in all areas of Thailand completed a questionnaire comprising the Thai SF-36 (Version 1). Median age was 31 years. Psychometric tests recommended by the International Quality of Life Assessment Project were used. Data quality was satisfactory: questionnaire completion rate was high (97.5%) and missing data rates were low (Vitality scale correlated better with the Mental Health scale than with itself, possibly because a healthy mental state is central to the concept of vitality in Thailand. The summated ratings method can be used for scoring the Thai SF-36. The instrument was found to be reliable and valid for use in a general non-clinical population. Version 2 of the SF-36 could improve ceiling and floor effects in the role functioning scales. Further work is warranted to refine items that measure the concepts of social functioning, vitality and mental health to improve the reliability and discriminant validity of these scales.

  12. Thai SF-36 health survey: tests of data quality, scaling assumptions, reliability and validity in healthy men and women

    Directory of Open Access Journals (Sweden)

    Sleigh Adrian

    2008-07-01

    Full Text Available Abstract Background Since its translation to Thai in 2000, the SF-36 Health Survey has been used extensively in many different clinical settings in Thailand. Its popularity has increased despite the absence of published evidence that the translated instrument satisfies scoring assumptions, the psychometric properties required for valid interpretation of the SF-36 summated ratings scales. The purpose of this paper was to examine these properties and to report on the reliability and validity of the Thai SF-36 in a non-clinical general population. Methods 1345 distance-education university students who live in all areas of Thailand completed a questionnaire comprising the Thai SF-36 (Version 1. Median age was 31 years. Psychometric tests recommended by the International Quality of Life Assessment Project were used. Results Data quality was satisfactory: questionnaire completion rate was high (97.5% and missing data rates were low ( Conclusion The summated ratings method can be used for scoring the Thai SF-36. The instrument was found to be reliable and valid for use in a general non-clinical population. Version 2 of the SF-36 could improve ceiling and floor effects in the role functioning scales. Further work is warranted to refine items that measure the concepts of social functioning, vitality and mental health to improve the reliability and discriminant validity of these scales.

  13. The Study of Factor Structure and Reliability of an Abbreviated School Climate Survey

    Science.gov (United States)

    Ding, Cody; Liu, Ying; Berkowitz, Marvin

    2011-01-01

    The concept of school climate has been an important variable in research on quality of school life and student learning. One of the challenges in such a research effort is to develop instruments that could effectively and efficiently measure the construct. The purpose of the current study was to examine the factor structure and reliability of an…

  14. A Survey Instrument for Measuring the Experiential Value of Employee-Tourist Encounters

    DEFF Research Database (Denmark)

    Mattsson, Jan; Sørensen, Flemming; Jensen, Jens Friis

    In this paper, we develop and test a survey instrument that aims at estimating the experiential value of employee-tourist encounters in destination-based tourism companies, as well as the characteristics of encounters that affect such experiential value. We suggest that such an instrument can...... for their visitors, rather than simply delivering service quality....

  15. ICA Communication Audit Survey Instrument: 1977 Organizational Norms.

    Science.gov (United States)

    Goldhaber, Gerald M.; And Others

    Section one of this paper describes the history and development of the "communicaton audit," a system for assessing communication effectiveness in organizations, by the International Communication Association. Section two describes the 16 audits conducted so far and the overall demographic characteristics of the current survey data bank.…

  16. The Toronto outcome measure for craniofacial prosthetics: reliability and validity of a condition-specific quality-of-life instrument.

    Science.gov (United States)

    Anderson, James D; Johnston, Dennis A; Haugh, Gil S; Kiat-Amnuay, Sudarat; Gettleman, Lawrence

    2013-01-01

    The purpose of this study was to refine the Toronto Outcome Measure for Craniofacial Prosthetics (TOMCP), present evidence for its reliability and validity, and use the instrument to explore differences in quality of life between prostheses made with chlorinated polyethylene (CPE) (experimental) and silicone (control). As part of a multicenter prospective controlled randomized double-blind single-crossover clinical trial of the two materials, the TOMCP was administered at the start and end of two 4-month study arms, during which 42 patients wore prostheses made from one material then the other. Reliability was assessed at the crossover. To determine validity of the TOMCP, the Linear Analogue Self-Assessment (LASA-12) and the Short-Form 8 (SF-8) were also administered with the TOMCP. The TOMCP was reduced by removing items that were unreliable, had poorly distributed answers, showed increased internal consistency after their removal, or were too highly correlated with more than one other item. The tests of reliability and validity were then repeated. Finally, the reduced instrument was used to test for differences in quality of life between prostheses made of the two materials. The item reduction tactics pared the 52-item instrument down to 27 items. The correlations of both TOMCP versions with the LASA-12 and the SF-8 were found to be statistically significant, providing evidence of the validity of the TOMCP. The instrument revealed significantly better quality of life with silicone rather than CPE prostheses. Both versions of the TOMCP were found to be reliable and valid. The instrument was able to show differences in quality of life between two materials.

  17. Survey of instrumentation used for monitoring metals in water

    Energy Technology Data Exchange (ETDEWEB)

    Quinby-Hunt, M.S.

    1978-06-01

    A study was conducted of instrumentation used to determine metals in water. Several of the techniques most commonly used for analysis and routine determinations of metals in water are shown in Table 1. They are atomic absorption spectroscopy, both flame and flameless, atomic emission spectroscopy using conventional flame sources and inductively-coupled plasma sources, and ultraviolet-visible absorption techniques. Other less frequently employed methods are x-ray fluorescence analysis using both photon and charged particle excitation with energy-dispersive and wavelength-dispersive spectral analysis. Also electrochemical techniques and activation analysis are studied.

  18. The Maastricht Clinical Teaching Questionnaire (MCTQ) as a valid and reliable instrument for the evaluation of clinical teachers.

    Science.gov (United States)

    Stalmeijer, Renée E; Dolmans, Diana H J M; Wolfhagen, Ineke H A P; Muijtjens, Arno M M; Scherpbier, Albert J J A

    2010-11-01

    Clinical teaching's importance in the medical curriculum has led to increased interest in its evaluation. Instruments for evaluating clinical teaching must be theory based, reliable, and valid. The Maastricht Clinical Teaching Questionnaire (MCTQ), based on the theoretical constructs of cognitive apprenticeship, elicits evaluations of individual clinical teachers' performance at the workplace. The authors investigated its construct validity and reliability, and they used the underlying factors to test a causal model representing effective clinical teaching. Between March 2007 and December 2008, the authors asked students who had completed clerkship rotations in different departments of two teaching hospitals to use the MCTQ to evaluate their clinical teachers. To establish construct validity, the authors performed a confirmatory factor analysis of the evaluation data, and they estimated reliability by calculating the generalizability coefficient and standard error measurement. Finally, to test a model of the factors, they fitted a structural linear model to the data. Confirmatory factor analysis yielded a five-factor model which fit the data well. Generalizability studies indicated that 7 to 10 student ratings can produce reliable ratings of individual teachers. The hypothesized structural linear model underlined the central roles played by modeling and coaching (mediated by articulation). The MCTQ is a valid and reliable evaluation instrument, thereby demonstrating the usefulness of the cognitive apprenticeship concept for clinical teaching during clerkships. Furthermore, a valuable model of clinical teaching emerged, highlighting modeling, coaching, and stimulating students' articulation and exploration as crucial to effective teaching at the clinical workplace.

  19. Developing the Coach Analysis and Intervention System (CAIS): establishing validity and reliability of a computerised systematic observation instrument.

    Science.gov (United States)

    Cushion, Christopher; Harvey, Stephen; Muir, Bob; Nelson, Lee

    2012-01-01

    We outline the evolution of a computerised systematic observation tool and describe the process for establishing the validity and reliability of this new instrument. The Coach Analysis and Interventions System (CAIS) has 23 primary behaviours related to physical behaviour, feedback/reinforcement, instruction, verbal/non-verbal, questioning and management. The instrument also analyses secondary coach behaviour related to performance states, recipient, timing, content and questioning/silence. The CAIS is a multi-dimensional and multi-level mechanism able to provide detailed and contextualised data about specific coaching behaviours occurring in complex and nuanced coaching interventions and environments that can be applied to both practice sessions and competition.

  20. A survey on the VXIbus and validity analyses for instrumentation and control in NPPs

    International Nuclear Information System (INIS)

    Kwon, Kee Choon; Park, Won Man

    1997-06-01

    This document presents the technical status of the VXIbus system and its interface. VMEbus, while developed as a backplane for Motorola processors, can be used for data acquisition, control and other instrumentation applications. The VXIbus and its associated standard for form, fit, and electrical interface have simplified the process of putting together automated instrumentation systems. The VXIplug and play system alliance was founded in 1993, the alliance's charter to improve the effectiveness of VXI-based solutions by increasing ease-of-use and improving the interoperability of mainframes, computers, instrumentations, and software through open, multivendor standards and practices. This technical report surveys surveys the instrumentation and control in NPPs apply to the VXI-based instruments which are studied expendability, interoperability, maintainability and other features. (author). 10 refs., 4 tabs., 25 figs

  1. Reliability and validity of the Safe Routes to school parent and student surveys

    Directory of Open Access Journals (Sweden)

    Evenson Kelly R

    2011-06-01

    Full Text Available Abstract Background The purpose of this study is to assess the reliability and validity of the U.S. National Center for Safe Routes to School's in-class student travel tallies and written parent surveys. Over 65,000 tallies and 374,000 parent surveys have been completed, but no published studies have examined their measurement properties. Methods Students and parents from two Charlotte, NC (USA elementary schools participated. Tallies were conducted on two consecutive days using a hand-raising protocol; on day two students were also asked to recall the previous days' travel. The recall from day two was compared with day one to assess 24-hour test-retest reliability. Convergent validity was assessed by comparing parent-reports of students' travel mode with student-reports of travel mode. Two-week test-retest reliability of the parent survey was assessed by comparing within-parent responses. Reliability and validity were assessed using kappa statistics. Results A total of 542 students participated in the in-class student travel tally reliability assessment and 262 parent-student dyads participated in the validity assessment. Reliability was high for travel to and from school (kappa > 0.8; convergent validity was lower but still high (kappa > 0.75. There were no differences by student grade level. Two-week test-retest reliability of the parent survey (n = 112 ranged from moderate to very high for objective questions on travel mode and travel times (kappa range: 0.62 - 0.97 but was substantially lower for subjective assessments of barriers to walking to school (kappa range: 0.31 - 0.76. Conclusions The student in-class student travel tally exhibited high reliability and validity at all elementary grades. The parent survey had high reliability on questions related to student travel mode, but lower reliability for attitudinal questions identifying barriers to walking to school. Parent survey design should be improved so that responses clearly indicate

  2. Reliability and validity of the Safe Routes to school parent and student surveys.

    Science.gov (United States)

    McDonald, Noreen C; Dwelley, Amanda E; Combs, Tabitha S; Evenson, Kelly R; Winters, Richard H

    2011-06-08

    The purpose of this study is to assess the reliability and validity of the U.S. National Center for Safe Routes to School's in-class student travel tallies and written parent surveys. Over 65,000 tallies and 374,000 parent surveys have been completed, but no published studies have examined their measurement properties. Students and parents from two Charlotte, NC (USA) elementary schools participated. Tallies were conducted on two consecutive days using a hand-raising protocol; on day two students were also asked to recall the previous days' travel. The recall from day two was compared with day one to assess 24-hour test-retest reliability. Convergent validity was assessed by comparing parent-reports of students' travel mode with student-reports of travel mode. Two-week test-retest reliability of the parent survey was assessed by comparing within-parent responses. Reliability and validity were assessed using kappa statistics. A total of 542 students participated in the in-class student travel tally reliability assessment and 262 parent-student dyads participated in the validity assessment. Reliability was high for travel to and from school (kappa > 0.8); convergent validity was lower but still high (kappa > 0.75). There were no differences by student grade level. Two-week test-retest reliability of the parent survey (n=112) ranged from moderate to very high for objective questions on travel mode and travel times (kappa range: 0.62-0.97) but was substantially lower for subjective assessments of barriers to walking to school (kappa range: 0.31-0.76). The student in-class student travel tally exhibited high reliability and validity at all elementary grades. The parent survey had high reliability on questions related to student travel mode, but lower reliability for attitudinal questions identifying barriers to walking to school. Parent survey design should be improved so that responses clearly indicate issues that influence parental decision making in regards to their

  3. The Development, Validity, and Reliability of a Psychometric Instrument Measuring Competencies in Student Affairs

    Science.gov (United States)

    Sriram, Rishi

    2014-01-01

    The study of competencies in student affairs began more than 4 decades ago, but no instrument currently exists to measure competencies broadly. This study builds upon previous research by developing an instrument to measure student affairs competencies. Results not only validate the competencies espoused by NASPA and ACPA, but also suggest adding…

  4. Probabilistic safety assessment for instrumentation and control systems in nuclear power plants. A literature survey

    International Nuclear Information System (INIS)

    Lu, Lixuan; Jiang, Jin

    2003-01-01

    Deregulation in electricity market will create a great deal of challenges for Nuclear Power Plants (NPP). To stay competitive, NPP will need to find new ways to reduce their operation costs. In NPP, Instrumentation and Control (I and C) systems play an important role in reducing the cost of producing electricity while maintaining and/or enhancing safety. Therefore, it is extremely important that one should manage the I and C systems more efficiently and economically. Meanwhile, obsolescence problem associated with I and C systems encouraged the usage of advanced digital techniques in I and C systems. Thus, new methodologies are needed to analyze the reliability and determine the maintenance strategy for the digital I and C systems. Probabilistic Safety Assessment (PSA) has been probed to be a promising method to deal with this issue. This paper provides a literature survey on the development of digital I and C systems in NPP, followed by a detailed review of PSA including its benefits, limitations and the future direction of its development. Most importantly, potential applications of PSA in various aspects of I and C systems are brought into perspective throughout the paper. Furthermore, the applicability of PSA in the regulation of safety-related I and C systems is demonstrated. Detailed information on PSA applications in 1) the resource allocation for I and C systems: 2) the determination of surveillance testing strategies; and 3) I and C system designs, is provided. (author)

  5. Reliability of patient-reported outcome instruments in US adults with hemophilia: the Pain, Functional Impairment and Quality of life (P-FiQ study

    Directory of Open Access Journals (Sweden)

    Kempton CL

    2017-09-01

    Full Text Available Christine L Kempton,1 Michael Wang,2 Michael Recht,3 Anne Neff,4 Amy D Shapiro,5 Amit Soni,6 Roshni Kulkarni,7 Tyler W Buckner,2 Katharine Batt,8 Neeraj N Iyer,9 David L Cooper9 1Departments of Pediatrics and Hematology and Medical Oncology, Emory University School of Medicine, Atlanta, GA, USA; 2Hemophilia and Thrombosis Center, University of Colorado School of Medicine, Aurora, CO, USA; 3The Hemophilia Center, Oregon Health & Science University, Portland, OR, USA; 4Hematology and Medical Oncology, Cleveland Clinic, Cleveland, OH, USA; 5Indiana Hemophilia & Thrombosis Center, Indianapolis, IN, USA; 6Center for Inherited Blood Disorders and CHOC Children’s Hospital/UC Irvine, Orange, CA, USA; 7MSU Center for Bleeding and Clotting Disorders, Michigan State University, East Lansing, MI, USA; 8Hematology and Oncology, Wake Forest School of Medicine, Winston-Salem, NC, USA; 9Clinical, Medical and Regulatory Affairs, Novo Nordisk Inc., Plainsboro, NJ, USA Background: Hemophilia is marked by frequent joint bleeding, resulting in pain and functional impairment.Objective: This study aimed to assess the reliability of five patient-reported outcome (PRO instruments in people with hemophilia (PWH in a non-bleeding state.Methods: Adult male PWH of any severity and inhibitor status, with a history of joint pain or bleeding, completed a pain history and five PRO instruments (EQ-5D-5L, Brief Pain Inventory v2 [BPI], International Physical Activity Questionnaire [IPAQ], Short Form 36 Health Survey v2 [SF-36v2], and Hemophilia Activities List [HAL] during their routine comprehensive care visit. Patients were approached to complete the PRO instruments again at the end of their visit while in a similar non-bleeding state. Concordance of individual questionnaire items and correlation between domain scores were assessed using intra-class correlation coefficient (ICC.Results: Participants completing the retest (n=164 had a median age of 33.9 years. Median time for

  6. Reliability and validity of the Safe Routes to school parent and student surveys

    OpenAIRE

    McDonald, Noreen C; Dwelley, Amanda E; Combs, Tabitha S; Evenson, Kelly R; Winters, Richard H

    2011-01-01

    Abstract Background The purpose of this study is to assess the reliability and validity of the U.S. National Center for Safe Routes to School's in-class student travel tallies and written parent surveys. Over 65,000 tallies and 374,000 parent surveys have been completed, but no published studies have examined their measurement properties. Methods Students and parents from two Charlotte, NC (USA) elementary schools participated. Tallies were conducted on two consecutive days using a hand-raisi...

  7. Development and reliability testing of the Nordic Housing Enabler – an instrument for accessibility assessment of the physical housing

    DEFF Research Database (Denmark)

    Helle, Tina

    and adapted according to accessibility norms and guidelines for housing design in Sweden, Denmark, Iceland and Finland. This iterative process involved occupational therapists, architects, building engineers and professional translators, resulting in the Nordic Housing Enabler. For reliability testing...... serious deficits when it comes to accessibility. This study addresses development of a content valid cross-Nordic version of the Housing Enabler and investigation of inter-rater reliability, when used in occupational therapy practice. The instrument was translated from the original Swedish version......, the sample strategy and data collection procedures were the same in all countries. In total, twenty voluntary occupational therapists collected data from 106 cases by means of the Nordic Housing Enabler. Inter-rater reliability was calculated by means of percentage agreement and kappa statistics. Overall...

  8. Developing a Survey Instrument for Evaluating the Effectiveness of Data Management Training Materials

    Science.gov (United States)

    Hou, C. Y.; Soyka, H.; Hutchison, V.; Budden, A. E.

    2016-12-01

    Education and training resources that focus on best practices and guidelines for working with data such as: data management, data sharing, quality metadata creation, and maintenance for reuse, have vital importance not only to the users of Data Observation Network for Earth (DataONE), but also to the broader scientific, research, and academic communities. However, creating and maintaining relevant training/educational materials that remain sensitive and responsive to community needs is dependent upon careful evaluations of the current landscape in order to promote and support thoughtful development of new resources. Using DataONE's existing training/educational resources as the basis for this project, the authors have worked to develop an evaluation instrument that can be used to evaluate the effectiveness of data management training/education resources. The evaluation instrument is in the form of a digital questionnaire/survey. The evaluation instrument also includes the structure and content as recommended by the best practices/guidelines of questionnaire/survey design, based on a review of the literature. Additionally, the evaluation instrument can be customized to evaluate various training/education modalities and be implemented using a web-based questionnaire/survey platform. Finally, the evaluation instrument can be used for site-wide evaluation of DataONE teaching materials and resources, and once made publicly available and openly accessible, other organizations may also utilize the instrument. One key outcome of developing the evaluation instrument is to help in increasing the effectiveness of data management training/education resources across the Earth/Geoscience community. Through this presentation, the authors will provide the full background and motivations for creating an instrument for evaluating the effectiveness of data management training/education resources. The presentation will also discuss in detail the process and results of the current

  9. Examining the Reliability and Validity of a Turkish Version of the Community of Inquiry Survey

    Science.gov (United States)

    Olpak, Yusuf Ziya; Kiliç Çakmak, Ebru

    2018-01-01

    The aim of this study was to describe the validity and reliability of a Turkish language version of the CoI survey developed by Arbaugh et al. (2008). Data were obtained from 1150 students enrolled in online courses in various departments in three Turkish state universities. The data were randomly divided into two parts: the first part was…

  10. Surveys Assessing Students' Attitudes toward Statistics: A Systematic Review of Validity and Reliability

    Science.gov (United States)

    Nolan, Meaghan M.; Beran, Tanya; Hecker, Kent G.

    2012-01-01

    Students with positive attitudes toward statistics are likely to show strong academic performance in statistics courses. Multiple surveys measuring students' attitudes toward statistics exist; however, a comparison of the validity and reliability of interpretations based on their scores is needed. A systematic review of relevant electronic…

  11. A Brazilian Portuguese Survey of School Climate: Evidence of Validity and Reliability

    Science.gov (United States)

    Bear, George G.; Holst, Bruna; Lisboa, Carolina; Chen, Dandan; Yang, Chunyan; Chen, Fang Fang

    2016-01-01

    This study presents evidence of the validity and reliability of scores for the newly developed Brazilian Portuguese version of the Delaware School Climate Survey-Student (Brazilian DSCS-S). The sample consisted of 378 students, grades 5 through 9, attending four private and three public schools in southern Brazil. Confirmatory factor analyses…

  12. Examining the Reliability and Validity of the Effective Behavior Support Self-Assessment Survey

    Science.gov (United States)

    Solomon, Benjamin G.; Tobin, Kevin G.; Schutte, Gregory M.

    2015-01-01

    The Effective Behavior Support Self-Assessment Survey (SAS; Sugai, Horner, & Todd, 2003) is designed to measure perceived Positive Behavior Interventions and Supports (PBIS) implementation and identify priorities for improvement. Despite its longevity, little published research exists documenting its reliability or validity for these purposes.…

  13. Reliability and validity of the Attributional Style Questionnaire- Survey in people with multiple sclerosis

    Science.gov (United States)

    Kneebone, Ian I.; Dewar, Sophie J.

    2016-01-01

    Background: The current study aimed to examine the psychometric properties of an attributional style measure that can be administered remotely, to people who have multiple sclerosis (MS). Methods: A total of 495 participants with MS were recruited. Participants completed the Attributional Style Questionnaire-Survey (ASQ-S) and two comparison measures of cognitive variables via postal survey on three occasions, each 12 months apart. Internal reliability, test-retest reliability and congruent validity were considered. Results: The internal reliability of the ASQ-S was good (α > 0.7). The test-retest correlations were significant, but failed to reach the 0.7 set. The congruent validity of the ASQ-S was established relative to the comparisons. Conclusions: The psychometric properties of the ASQ-S indicate that it shows promise as a tool for researchers investigating depression in people with MS and is likely sound to use clinically in this population. PMID:28450893

  14. Face validity and reliability of a pictorial instrument for assessing fundamental movement skill perceived competence in young children.

    Science.gov (United States)

    Barnett, Lisa M; Ridgers, Nicola D; Zask, Avigdor; Salmon, Jo

    2015-01-01

    To determine reliability and face validity of an instrument to assess young children's perceived fundamental movement skill competence. Validation and reliability study. A pictorial instrument based on the Test Gross Motor Development-2 assessed perceived locomotor (six skills) and object control (six skills) competence using the format and item structure from the physical competence subscale of the Pictorial Scale of Perceived Competence and Acceptance for Young Children. Sample 1 completed object control items in May (n=32) and locomotor items in October 2012 (n=23) at two time points seven days apart. Children were asked at the end of the test-retest their understanding of what was happening in each picture to determine face validity. Sample 2 (n=58) completed 12 items in November 2012 on a single occasion to test internal reliability only. Sample 1 children were aged 5-7 years (M=6.0, SD=0.8) at object control assessment and 5-8 years at locomotor assessment (M=6.5, SD=0.9). Sample 2 children were aged 6-8 years (M=7.2, SD=0.73). Intra-class correlations assessed in Sample 1 children were excellent for object control (intra-class correlation=0.78), locomotor (intra-class correlation=0.82) and all 12 skills (intra-class correlations=0.83). Face validity was acceptable. Internal consistency was adequate in both samples for each subscale and all 12 skills (alpha range 0.60-0.81). This study has provided preliminary evidence for instrument reliability and face validity. This enables future alignment between the measurement of perceived and actual fundamental movement skill competence in young children. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  15. Modelling of nuclear power plant control and instrumentation elements for automatic disturbance and reliability analysis

    International Nuclear Information System (INIS)

    Hollo, E.

    1985-08-01

    Present Final Report summarizes results of R/D work done within IAEA-VEIKI (Institute for Electrical Power Research, Budapest, Hungary) Research Contract No. 3210 during 3 years' period of 01.08.1982 - 31.08.1985. Chapter 1 lists main research objectives of the project. Main results obtained are summarized in Chapters 2 and 3. Outcomes from development of failure modelling methodologies and their application for C/I components of WWER-440 units are as follows (Chapter 2): improvement of available ''failure mode and effect analysis'' methods and mini-fault tree structures usable for automatic disturbance (DAS) and reliability (RAS) analysis; general classification and determination of functional failure modes of WWER-440 NPP C/I components; set up of logic models for motor operated control valves and rod control/drive mechanism. Results of development of methods and their application for reliability modelling of NPP components and systems cover (Chapter 3): development of an algorithm (computer code COMPREL) for component-related failure and reliability parameter calculation; reliability analysis of PAKS II NPP diesel system; definition of functional requirements for reliability data bank (RDB) in WWER-440 units. Determination of RDB input/output data structure and data manipulation services. Methods used are a-priori failure mode and effect analysis, combined fault tree/event tree modelling technique, structural computer programming, probability theory application to nuclear field

  16. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  17. ARABIC TRANSLATION AND ADAPTATION OF THE HOSPITAL CONSUMER ASSESSMENT OF HEALTHCARE PROVIDERS AND SYSTEMS (HCAHPS) PATIENT SATISFACTION SURVEY INSTRUMENT.

    Science.gov (United States)

    Dockins, James; Abuzahrieh, Ramzi; Stack, Martin

    2015-01-01

    To translate and adapt an effective, validated, benchmarked, and widely used patient satisfaction measurement tool for use with an Arabic-speaking population. Translation of survey's items, survey administration process development, evaluation of reliability, and international benchmarking Three hundred-bed tertiary care hospital in Jeddah, Saudi Arabia. 645 patients discharged during 2011 from the hospital's inpatient care units. INTERVENTIONS; The Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) instrument was translated into Arabic, a randomized weekly sample of patients was selected, and the survey was administered via telephone during 2011 to patients or their relatives. Scores were compiled for each of the HCAHPS questions and then for each of the six HCAHPS clinical composites, two non-clinical items, and two global items. Clinical composite scores, as well as the two non-clinical and two global items were analyzed for the 645 respondents. Clinical composites were analyzed using Spearman's correlation coefficient and Cronbach's alpha to demonstrate acceptable internal consistency for these items and scales demonstrated acceptable internal consistency for the clinical composites. (Spearman's correlation coefficient = 0.327 - 0.750, P quarterly to US national averages with results that closely paralleled the US benchmarks. . The Arabic translation and adaptation of the HCAHPS is a valid, reliable, and feasible tool for evaluation and benchmarking of inpatient satisfaction in Arabic speaking populations.

  18. Establishing survey validity and reliability for American Indians through "think aloud" and test-retest methods.

    Science.gov (United States)

    Hauge, Cindy Horst; Jacobs-Knight, Jacque; Jensen, Jamie L; Burgess, Katherine M; Puumala, Susan E; Wilton, Georgiana; Hanson, Jessica D

    2015-06-01

    The purpose of this study was to use a mixed-methods approach to determine the validity and reliability of measurements used within an alcohol-exposed pregnancy prevention program for American Indian women. To develop validity, content experts provided input into the survey measures, and a "think aloud" methodology was conducted with 23 American Indian women. After revising the measurements based on this input, a test-retest was conducted with 79 American Indian women who were randomized to complete either the original measurements or the new, modified measurements. The test-retest revealed that some of the questions performed better for the modified version, whereas others appeared to be more reliable for the original version. The mixed-methods approach was a useful methodology for gathering feedback on survey measurements from American Indian participants and in indicating specific survey questions that needed to be modified for this population. © The Author(s) 2015.

  19. Evaluation and Monte Carlo modelling of the response function of the Leake neutron area survey instrument

    International Nuclear Information System (INIS)

    Tagziria, H.; Tanner, R.J.; Bartlett, D.T.; Thomas, D.J.

    2004-01-01

    All available measured data for the response characteristics of the Leake counter have been gathered together. These data, augmented by previously unpublished work, have been compared to Monte Carlo simulations of the instrument's response characteristics in the energy range from thermal to 20 MeV. A response function has been derived, which is recommended as the best currently available for the instrument. Folding this function with workplace energy distributions has enabled an assessment of the impact of this new response function to be made. Similar work, which will be published separately, has been carried out for the NM2 and the Studsvik 2202D neutron area survey instruments

  20. Antisocial personality disorder and psychopathy in women: a literature review on the reliability and validity of assessment instruments.

    Science.gov (United States)

    Dolan, Mairead; Völlm, Birgit

    2009-01-01

    Crime rates are low in women compared to men. The two disorders most commonly associated with offending behaviour, antisocial personality disorder (ASPD) and psychopathy, are also less prevalent in female samples. However, developments in forensic psychiatry have often ignored gender, and the utility of constructs such as psychopathy and their assessment instruments in female samples remains unclear. This article presents a review of studies looking at rates of ASPD and psychopathy and on the reliability and validity of assessment instruments of these disorders in women. Gender differences in symptom patterns will be considered. The literature seems to suggest that DSM-IV criteria for ASPD may lead to an underestimation of the prevalence of the disorder in women due to the requirement of childhood conduct disorder symptoms. The Psychopathy Checklist-Revised (PCL-R) is a valid and reliable instrument to identify psychopathy in women but there are gender differences in the factor structure and item loadings on this measure. Research to date seems to suggest a three-factor model may be most strongly supported in females. Preliminary evidence suggests the PCL-R may have some value in predicting future offending while the PCL:SV may be useful in predicting institutional violence. Clinical implications are discussed.

  1. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  2. Quantitative assessment of probability of failing safely for the safety instrumented system using reliability block diagram method

    International Nuclear Information System (INIS)

    Jin, Jianghong; Pang, Lei; Zhao, Shoutang; Hu, Bin

    2015-01-01

    Highlights: • Models of PFS for SIS were established by using the reliability block diagram. • The more accurate calculation of PFS for SIS can be acquired by using SL. • Degraded operation of complex SIS does not affect the availability of SIS. • The safe undetected failure is the largest contribution to the PFS of SIS. - Abstract: The spurious trip of safety instrumented system (SIS) brings great economic losses to production. How to ensure the safety instrumented system is reliable and available has been put on the schedule. But the existing models on spurious trip rate (STR) or probability of failing safely (PFS) are too simplified and not accurate, in-depth studies of availability to obtain more accurate PFS for SIS are required. Based on the analysis of factors that influence the PFS for the SIS, using reliability block diagram method (RBD), the quantitative study of PFS for the SIS is carried out, and gives some application examples. The results show that, the common cause failure will increase the PFS; degraded operation does not affect the availability of the SIS; if the equipment was tested and repaired one by one, the unavailability of the SIS can be ignored; the corresponding occurrence time of independent safe undetected failure should be the system lifecycle (SL) rather than the proof test interval and the independent safe undetected failure is the largest contribution to the PFS for the SIS

  3. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  4. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  5. Reliability and Validity of the "Decision-Making Skills Instrument for Children"

    Science.gov (United States)

    Pekdogan, Serpil; Ulutas, Ilkay

    2016-01-01

    The purpose of this study is to develop a valid and reliable data collection tool to assess the decision-making skills of children at the age of 5 to 6. The study group is composed of 300 children attending independent pre-schools located in the central district of Amasya province and their parents. In the study, four-factor and 29-item…

  6. The Reliability and Validity of a Campus Caring Instrument Developed for Undergraduate Students in Hong Kong

    Science.gov (United States)

    Ng, Petrus; Su, Xiqing Susan; Chan, Vivien; Leung, Heidi; Cheung, Wendy; Tsun, Angela

    2013-01-01

    This study validated a Perceived Campus Caring Scale with 1,520 university students. Using factor analysis, seven factors namely, Faculty Support, Nonfaculty Support, Peer Relationship, Sense of Detachment, Sense of Belonging, Caring Attitude, and Campus Involvement, are identified with high reliability, validity, and close correlation with the…

  7. Internal consistency reliability and validity of the Arabic translation of the Mathematics Teaching Efficacy Beliefs Instrument.

    Science.gov (United States)

    Alkhateeb, Haitham M

    2004-06-01

    The Arabic translation of the Mathematics Teaching Efficacy Beliefs was completed by 144 undergraduate students (M age=20.6) in Jordan. The findings support the internal reliability of the Arabic translation of the Mathematics Teaching Efficacy Beliefs as well as its construct validity.

  8. Development and testing of the Youth Alcohol Norms Survey (YANS) instrument to measure youth alcohol norms and psychosocial influences.

    Science.gov (United States)

    Burns, Sharyn K; Maycock, Bruce; Hildebrand, Janina; Zhao, Yun; Allsop, Steve; Lobo, Roanna; Howat, Peter

    2018-05-14

    This study aimed to develop and validate an online instrument to: (1) identify common alcohol-related social influences, norms and beliefs among adolescents; (2) clarify the process and pathways through which proalcohol norms are transmitted to adolescents; (3) describe the characteristics of social connections that contribute to the transmission of alcohol norms; and (4) identify the influence of alcohol marketing on adolescent norm development. The online Youth Alcohol Norms Survey (YANS) was administered in secondary schools in Western Australia PARTICIPANTS: Using a 2-week test-retest format, the YANS was administered to secondary school students (n=481, age=13-17 years, female 309, 64.2%). The development of the YANS was guided by social cognitive theory and comprised a systematic multistage process including evaluation of content and face validity. A 2-week test-retest format was employed. Exploratory factor analysis was conducted to determine the underlying factor structure of the instrument. Test-retest reliability was examined using intraclass correlation coefficient (ICC) and Cohen's kappa. A five-factor structure with meaningful components and robust factorial loads was identified, and the five factors were labelled as 'individual attitudes and beliefs', 'peer and community identity', 'sibling influences', 'school and community connectedness' and 'injunctive norms', respectively. The instrument demonstrated stability across the test-retest procedure (ICC=0.68-0.88, Cohen's kappa coefficient=0.69) for most variables. The results support the reliability and factorial validity of this instrument. The YANS presents a promising tool, which enables comprehensive assessment of reciprocal individual, behavioural and environmental factors that influence alcohol-related norms among adolescents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise

  9. Trans-adapted, reliability, and validity of children fear survey schedule-dental subscale in Bahasa Indonesia

    Directory of Open Access Journals (Sweden)

    Arlette Suzy

    2015-03-01

    Full Text Available Background: The most frequently used measuring instrument for determination of dental fear in children nowadays is the children’s fear survey schedule-dental scale (CFSS-DS. Purpose: The purpose of this study was to explore the reliability and validity of the scale with Indonesian trans adapted version of the scale, thus the scale can be reliable to be used in other similar research in Indonesia. Methods: Total of 113 participants, who were parent’s 3 to 12 years old children. Children were divided into two age groups, group I 3-6 year old (83 children and group II 7-12 year old (30 children. Eighty three children from the first group were divided into first dental visit group (30 children and non first dental visit group (53 children. Test-retest approach was applied to 30 first dental visit children aged 3-6 year old. Original scale was translated to Indonesian language. Result: The result showed the high value of the Cronbach’s coefficient of internal consistency α=0.956. Three factors were extracted by screen test method with Eigen values higher than 1, which explained 93.05% variance of results. Conclusion: CFSS-DS scale is reliable and valid psychometric instrument for dental fear evaluation in children in Bahasa Indonesia. The differences between this study and those of others may appear due to many factors. Normal 0 false false false EN-US X-NONE X-NONE

  10. Reliability and validity of self-reported smoking in an anonymous online survey with young adults.

    Science.gov (United States)

    Ramo, Danielle E; Hall, Sharon M; Prochaska, Judith J

    2011-11-01

    The Internet offers many potential benefits to conducting smoking and other health behavior research with young adults. Questions, however, remain regarding the psychometric properties of online self-reported smoking behaviors. The purpose of this study was to examine the reliability and validity of self-reported smoking and smoking-related cognitions obtained from an online survey. Young adults (N = 248) age 18 to 25 who had smoked at least 1 cigarette in the past 30 days were recruited online and completed a survey of tobacco and other substance use. Measures of smoking behavior (quantity and frequency) and smoking-related expectancies demonstrated high internal consistency reliability. Measures of smoking behavior and smoking stage of change demonstrated strong concurrent criterion and divergent validity. Results for convergent validity varied by specific constructs measured. Estimates of smoking quantity, but not frequency, were comparable to those obtained from a nationally representative household interview among young adults. These findings generally support the reliability and validity of online surveys of young adult smokers. Identified limitations may reflect issues specific to the measures rather than the online data collection methodology. Strategies to maximize the psychometric properties of online surveys with young adult smokers are discussed. PsycINFO Database Record (c) 2011 APA, all rights reserved.

  11. Reliability of an instrument to determine lower limb comfort in professional football

    Directory of Open Access Journals (Sweden)

    Michael Kinchington

    2010-06-01

    Full Text Available Michael Kinchington1, Kevin Ball1, Geraldine Naughton21School of Human Movement, Recreation and Performance, Victoria University, Melbourne, Australia; 2The Centre of Physical Activity Across the Lifespan (COPAAL, Australian Catholic University, Victoria, AustraliaAims and Objectives: This study extends previous work in the field of injury awareness using a novel lower limb comfort index (LLCI, which was developed to assess comfort in professional football. Participants rated comfort for designated anatomical segments of the lower limb utilizing a seven point Likert scale. The aims of the study were (i to assess the reliability of the LLCI in a competitive football environment (Australian Rules and Rugby League, and (ii to assess whether LLCI measurements were responsive to changes in lower limb comfort over time.Methods and Results: The reliability of the LLCI was observed in two professional football environments: Training Week (mean difference 0.1 point, intra-class correlation coefficient, ICC 0.99 for n = 41 participants; and Match Day (mean difference 0.2 points, ICC 0.97 for n = 22 players. Measurements of lower limb comfort were responsive to changes in comfort over time. Within-player differences were not significant for periods 0–8 hrs (P > 0.05 but, generally, significant for time periods 0–24 hrs (P < 0.05, and significant between 24–96 hrs (P < 0.01. The results indicate that the LLCI was reliable when tested for repeated measures and indicated how the index measures lower limb comfort changes over time.Conclusion: This study shows that the use of a lower limb comfort index, when used in a competitive football environment, is both reliable and responsive to change during both a training week and under match day conditions.Keywords: lower limb comfort, musculoskeletal, football, injury

  12. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  13. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  14. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  15. Reliable and adequateengineering surveys for construction: the rule of two D

    Directory of Open Access Journals (Sweden)

    Rakitina Natal'ya Nikolaevna

    2014-01-01

    Full Text Available In the article the current state of quality supply of engineering surveys for construction is discussed. The main criteria for improving the design quality of buildings and structures for industrial, civil and other purposes is the reliability and adequacy of the results of engineering-geological surveys. The authors show the examples of inadequate study of engineering-geological conditions in the design of structures that led to emergency situations. Consideration of the reasons of accidents in structures showed that they are caused by lack of research conducted, the underestimation of the complexity of geological conditions. In the process of conducting geotechnical investigations the works were focused directly in the enclosure of a designed building, and the features of geological and hydrogeological conditions of the off-site were much more complex. In the process of construction during the sinking of the pit activation suffusion processes occurred, which led to an accident. Underestimation of the use of these geological funds in this example shows that even in the presence of fund materials, which are currently almost not increased, errors may occur due to the notorious savings for research. The requirements to ensuring the reliability and adequacy of engineering-geological surveys, which the authors call "The Rule of two D" (in Russian — Reliability and Adequacy, lie in the existing legal acts. The practice of fulfilling requirements to a large extend shows that the desire to save money at the stage of design and exploration works results in additional costs for additional design, recovery from accidents and works on a new project. The authors critically evaluated the development of engineering and geotechnical engineering instead of geological survey, which is not methodologically and theoretically substantiated and leads to the excluding from engineering surveys the consideration of the off-site geotechnical conditions directly below

  16. Development and validation of a survey instrument to measure children's advertising literacy

    NARCIS (Netherlands)

    Rozendaal, E.; Opree, S.J.; Buijzen, M.A.

    2016-01-01

    The aim of this study was to develop and validate a survey measurement instrument for children's advertising literacy. Based on the multidimensional conceptualization of advertising literacy by 0056"> Rozendaal, Lapierre, Van Reijmersdal, and Buijzen (2011), 39 items were created to measure two

  17. Development and reliability testing of a self-report instrument to measure the office layout as a correlate of occupational sitting

    Directory of Open Access Journals (Sweden)

    Duncan Mitch J

    2013-02-01

    Full Text Available Abstract Background Spatial configurations of office environments assessed by Space Syntax methodologies are related to employee movement patterns. These methods require analysis of floors plans which are not readily available in large population-based studies or otherwise unavailable. Therefore a self-report instrument to assess spatial configurations of office environments using four scales was developed. Methods The scales are: local connectivity (16 items, overall connectivity (11 items, visibility of co-workers (10 items, and proximity of co-workers (5 items. A panel cohort (N = 1154 completed an online survey, only data from individuals employed in office-based occupations (n = 307 were used to assess scale measurement properties. To assess test-retest reliability a separate sample of 37 office-based workers completed the survey on two occasions 7.7 (±3.2 days apart. Redundant scale items were eliminated using factor analysis; Chronbach’s α was used to evaluate internal consistency and test re-test reliability (retest-ICC. ANOVA was employed to examine differences between office types (Private, Shared, Open as a measure of construct validity. Generalized Linear Models were used to examine relationships between spatial configuration scales and the duration of and frequency of breaks in occupational sitting. Results The number of items on all scales were reduced, Chronbach’s α and ICCs indicated good scale internal consistency and test re-test reliability: local connectivity (5 items; α = 0.70; retest-ICC = 0.84, overall connectivity (6 items; α = 0.86; retest-ICC = 0.87, visibility of co-workers (4 items; α = 0.78; retest-ICC = 0.86, and proximity of co-workers (3 items; α = 0.85; retest-ICC = 0.70. Significant (p ≤ 0.001 differences, in theoretically expected directions, were observed for all scales between office types, except overall connectivity. Significant associations were

  18. Comparing NICU teamwork and safety climate across two commonly used survey instruments.

    Science.gov (United States)

    Profit, Jochen; Lee, Henry C; Sharek, Paul J; Kan, Peggy; Nisbet, Courtney C; Thomas, Eric J; Etchegaray, Jason M; Sexton, Bryan

    2016-12-01

    Measurement and our understanding of safety culture are still evolving. The objectives of this study were to assess variation in safety and teamwork climate and in the neonatal intensive care unit (NICU) setting, and compare measurement of safety culture scales using two different instruments (Safety Attitudes Questionnaire (SAQ) and Hospital Survey on Patient Safety Culture (HSOPSC)). Cross-sectional survey study of a voluntary sample of 2073 (response rate 62.9%) health professionals in 44 NICUs. To compare survey instruments, we used Spearman's rank correlation coefficients. We also compared similar scales and items across the instruments using t tests and changes in quartile-level performance. We found significant variation across NICUs in safety and teamwork climate scales of SAQ and HSOPSC (pteamwork scales (teamwork climate and teamwork within units) of the two instruments correlated strongly (safety r=0.72, pteamwork r=0.67, p<0.001). However, the means and per cent agreements for all scale scores and even seemingly similar item scores were significantly different. In addition, comparisons of scale score quartiles between the two instruments revealed that half of the NICUs fell into different quartiles when translating between the instruments. Large variation and opportunities for improvement in patient safety culture exist across NICUs. Important systematic differences exist between SAQ and HSOPSC such that these instruments should not be used interchangeably. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Ethical issues in palliative care for nursing homes: Development and testing of a survey instrument.

    Science.gov (United States)

    Preshaw, Deborah Hl; McLaughlin, Dorry; Brazil, Kevin

    2018-02-01

    To develop and psychometrically assess a survey instrument identifying ethical issues during palliative care provision in nursing homes. Registered nurses and healthcare assistants have reported ethical issues in everyday palliative care provision. Identifying these issues provides evidence to inform practice development to support healthcare workers. Cross-sectional survey of Registered nurses and healthcare assistants in nursing homes in one region of the UK. A survey instrument, "Ethical issues in Palliative Care for Nursing homes", was developed through the findings of qualitative interviews with Registered nurses and healthcare assistants in nursing homes and a literature review. It was reviewed by an expert panel and piloted prior to implementation in a survey in 2015 with a convenience sample of 596 Registered nurses and healthcare assistants. Descriptive and exploratory factor analyses were used to assess the underlying structure of the Frequency and Distress Scales within the instrument. Analysis of 201 responses (response rate = 33.7%) revealed four factors for the Frequency Scale and five factors for the Distress Scale that comprise the Ethical issues in Palliative Care for Nursing homes. Factors common to both scales included "Processes of care," "Resident autonomy" and "Burdensome treatment." Additionally, the Frequency Scale included "Competency," and the Distress Scale included "Quality of care" and "Communication." The Ethical issues in Palliative Care for Nursing homes instrument has added to the palliative care knowledge base by considering the ethical issues experienced specifically by Registered nurses and healthcare assistants within the nursing home. This research offers preliminary evidence of the psychometric properties of the Ethical issues in Palliative Care for Nursing homes survey instrument. The two largest factors highlight the need to address the organisational aspects of caring and provide training in negotiating conflicting

  20. Survey and analysis on environmental and electromagnetic effect on instrumentation and control equipment of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, In Koo; Lee, Dong Young; Cha, Kyung Ho

    2001-03-01

    As the instrumentation and control (I and C) equipment suppliers tend to provide digital components rather than conventional analog type components for instrumentation and control systems of nuclear power plants(NPPs), it is unavoidable to adopt digital equipment for safety I and C systems as well as non-safety systems. However, the full introduction of digital equipment for I and C systems of nuclear power plants raises several concerns which have not been considered in conventional analog I and C equipment. The two major examples of the issues of digital systems are environmental/electromagnetic compatibility (EMC) and software reliability. This report presents the survey and research results on environmental and electromagnetic effect on I and C equipment of nuclear power plants to give a guideline for aging management and design process. Electromagnetic site surveys were conducted to be used as a part of technical basis to demonstrate that I and C systems are compatible with the ambient electromagnetic noise in Korean nuclear power plants.

  1. New instrument for measuring student beliefs about physics and learning physics: The Colorado Learning Attitudes about Science Survey

    Science.gov (United States)

    Adams, W. K.; Perkins, K. K.; Podolefsky, N. S.; Dubson, M.; Finkelstein, N. D.; Wieman, C. E.

    2006-06-01

    The Colorado Learning Attitudes about Science Survey (CLASS) is a new instrument designed to measure student beliefs about physics and about learning physics. This instrument extends previous work by probing additional aspects of student beliefs and by using wording suitable for students in a wide variety of physics courses. The CLASS has been validated using interviews, reliability studies, and extensive statistical analyses of responses from over 5000 students. In addition, a new methodology for determining useful and statistically robust categories of student beliefs has been developed. This paper serves as the foundation for an extensive study of how student beliefs impact and are impacted by their educational experiences. For example, this survey measures the following: that most teaching practices cause substantial drops in student scores; that a student’s likelihood of becoming a physics major correlates with their “Personal Interest” score; and that, for a majority of student populations, women’s scores in some categories, including “Personal Interest” and “Real World Connections,” are significantly different from men’s scores.

  2. The Modified Abbreviated Math Anxiety Scale: A Valid and Reliable Instrument for Use with Children.

    Science.gov (United States)

    Carey, Emma; Hill, Francesca; Devine, Amy; Szűcs, Dénes

    2017-01-01

    Mathematics anxiety (MA) can be observed in children from primary school age into the teenage years and adulthood, but many MA rating scales are only suitable for use with adults or older adolescents. We have adapted one such rating scale, the Abbreviated Math Anxiety Scale (AMAS), to be used with British children aged 8-13. In this study, we assess the scale's reliability, factor structure, and divergent validity. The modified AMAS (mAMAS) was administered to a very large ( n = 1746) cohort of British children and adolescents. This large sample size meant that as well as conducting confirmatory factor analysis on the scale itself, we were also able to split the sample to conduct exploratory and confirmatory factor analysis of items from the mAMAS alongside items from child test anxiety and general anxiety rating scales. Factor analysis of the mAMAS confirmed that it has the same underlying factor structure as the original AMAS, with subscales measuring anxiety about Learning and Evaluation in math. Furthermore, both exploratory and confirmatory factor analysis of the mAMAS alongside scales measuring test anxiety and general anxiety showed that mAMAS items cluster onto one factor (perceived to represent MA). The mAMAS provides a valid and reliable scale for measuring MA in children and adolescents, from a younger age than is possible with the original AMAS. Results from this study also suggest that MA is truly a unique construct, separate from both test anxiety and general anxiety, even in childhood.

  3. Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors.

    Science.gov (United States)

    Ruschel, Caroline; Haupenthal, Alessandro; Jacomel, Gabriel Fernandes; Fontana, Heiliane de Brito; Santos, Daniela Pacheco dos; Scoz, Robson Dias; Roesler, Helio

    2015-05-20

    Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance. To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force. Validity (concurrent approach) and reliability (test and test-retest approach) study. University laboratory. 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study). Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study). In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles. The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.

  4. Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.

    Science.gov (United States)

    Taylor, Karen; Bulsara, Max; Monterosso, Leanne

    2018-01-01

    Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.

  5. Development of a Conceptual Model and Survey Instrument to Measure Conscientious Objection to Abortion Provision.

    Directory of Open Access Journals (Sweden)

    Laura Florence Harris

    Full Text Available Conscientious objection to abortion, clinicians' refusal to perform legal abortions because of their religious or moral beliefs, has been the subject of increasing debate among bioethicists, policymakers, and public health advocates in recent years. Conscientious objection policies are intended to balance reproductive rights and clinicians' beliefs. However, in practice, clinician objection can act as a barrier to abortion access-impinging on reproductive rights, and increasing unsafe abortion and related morbidity and mortality. There is little information about conscientious objection from a medical or public health perspective. A quantitative instrument is needed to assess prevalence of conscientious objection and to provide insight on its practice. This paper describes the development of a survey instrument to measure conscientious objection to abortion provision.A literature review, and in-depth formative interviews with stakeholders in Colombia were used to develop a conceptual model of conscientious objection. This model led to the development of a survey, which was piloted, and then administered, in Ghana.The model posits three domains of conscientious objection that form the basis for the survey instrument: 1 beliefs about abortion and conscientious objection; 2 actions related to conscientious objection and abortion; and 3 self-identification as a conscientious objector.The instrument is intended to be used to assess prevalence among clinicians trained to provide abortions, and to gain insight on how conscientious objection is practiced in a variety of settings. Its results can inform more effective and appropriate strategies to regulate conscientious objection.

  6. Reliability analysis and computation of computer-based safety instrumentation and control used in German nuclear power plant. Final report

    International Nuclear Information System (INIS)

    Ding, Yongjian; Krause, Ulrich; Gu, Chunlei

    2014-01-01

    The trend of technological advancement in the field of safety instrumentation and control (I and C) leads to increasingly frequent use of computer-based (digital) control systems which consisting of distributed, connected bus communications computers and their functionalities are freely programmable by qualified software. The advantages of the new I and C system over the old I and C system with hard-wired technology are e.g. in the higher flexibility, cost-effective procurement of spare parts, higher hardware reliability (through higher integration density, intelligent self-monitoring mechanisms, etc.). On the other hand, skeptics see the new technology with the computer-based I and C a higher potential by influences of common cause failures (CCF), and the easier manipulation by sabotage (IT Security). In this joint research project funded by the Federal Ministry for Economical Affaires and Energy (BMWi) (2011-2014, FJZ 1501405) the Otto-von-Guericke-University Magdeburg and Magdeburg-Stendal University of Applied Sciences are therefore trying to develop suitable methods for the demonstration of the reliability of the new instrumentation and control systems with the focus on the investigation of CCF. This expertise of both houses shall be extended to this area and a scientific contribution to the sound reliability judgments of the digital safety I and C in domestic and foreign nuclear power plants. First, the state of science and technology will be worked out through the study of national and international standards in the field of functional safety of electrical and I and C systems and accompanying literature. On the basis of the existing nuclear Standards the deterministic requirements on the structure of the new digital I and C system will be determined. The possible methods of reliability modeling will be analyzed and compared. A suitable method called multi class binomial failure rate (MCFBR) which was successfully used in safety valve applications will be

  7. Instruments

    International Nuclear Information System (INIS)

    Buehrer, W.

    1996-01-01

    The present paper mediates a basic knowledge of the most commonly used experimental techniques. We discuss the principles and concepts necessary to understand what one is doing if one performs an experiment on a certain instrument. (author) 29 figs., 1 tab., refs

  8. Development, reliability, and validity of the Posttraumatic Stress Disorder Interview for Vietnamese refugees: a diagnostic instrument for Vietnamese refugees.

    Science.gov (United States)

    Dao, Tam K; Poritz, Julia M P; Moody, Rachel P; Szeto, Kim

    2012-08-01

    The Posttraumatic Stress Disorder Interview for Vietnamese Refugees (PTSD-IVR) was created specifically to assess for the presence of current and lifetime history of premigration, migration, encampment, and postmigration traumas in Vietnamese refugees. The purpose of the present study was to describe the development of and investigate the interrater and test-retest reliability of the PTSD-IVR and its validity in relation to the diagnoses obtained from the Longitudinal, Expert, and All Data (LEAD; Spitzer, 1983) standard. Clinicians conducted the diagnosis process with 127 Vietnamese refugees using the LEAD standard and the PTSD-IVR. Assessment of the reliability and validity of the PTSD-IVR yielded good to excellent AUC (area under the receiver operating characteristic curve; .86, .87) and κ values (.66, .74) indicating the reliability of the PTSD-IVR and the agreement between the LEAD procedure and the PTSD-IVR. The results of the present study suggest that the PTSD-IVR performs successfully as a diagnostic instrument specifically created for Vietnamese refugees in their native language. Copyright © 2012 International Society for Traumatic Stress Studies.

  9. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India.

    Science.gov (United States)

    Patil, Thimmanagowda N; Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-05-01

    The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher's-exact test and the Chi-Square test. Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced with increasing number of re use frequency and with

  10. Job analysis of the maintenance supervisor and instrument and control supervisor positions for the nuclear power plant maintenance personnel reliability model

    International Nuclear Information System (INIS)

    Bartter, W.D.; Siegel, A.I.; Federman, P.J.

    1982-11-01

    The present report presents the results of an analysis of the jobs of maintenance mechanic supervisors and instrument and control technician supervisors in nuclear power plants. Such an analysis was considered to be a necessary step in defining the scope and focus of a model for predicting and analyzing nuclear power maintenance reliability. The model will focus upon tasks and subtasks performed by various job positions. The results of this job analysis, along with the results of a survey of user needs vis-a-vis such a model and the results of parallel analyses of the job of maintenance mechanics and of instrument and control technicians provide the sound foundation on which such a model may be built. Job analysis possesses implications for a number of purposes. It provides insight into selection standards, job structuring and organization, performance analysis, training objective establishment, and training content derivation. Accordingly, the results of the present work possess implications for a variety of interest areas relative to safe and efficient operation of nuclear power plants

  11. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  12. Research on the evaluation model of the software reliability in nuclear safety class digital instrumentation and control system

    International Nuclear Information System (INIS)

    Liu Ying; Yang Ming; Li Fengjun; Ma Zhanguo; Zeng Hai

    2014-01-01

    In order to analyze the software reliability (SR) in nuclear safety class digital instrumentation and control system (D-I and C), firstly, the international software design standards were analyzed, the standards' framework was built, and we found that the D-I and C software standards should follow the NUREG-0800 BTP7-14, according to the NRC NUREG-0800 review of requirements. Secondly, the quantitative evaluation model of SR using Bayesian Belief Network and thirteen sub-model frameworks were established. Thirdly, each sub-models and the weight of corresponding indexes in the evaluation model were analyzed. Finally, the safety case was introduced. The models lay a foundation for review and quantitative evaluation on the SR in nuclear safety class D-I and C. (authors)

  13. Job analysis of the instrument and control technician position for the nuclear power plant maintenance personnel reliability model

    International Nuclear Information System (INIS)

    Siegel, A.I.; Bartter, W.D.; Federman, P.J.

    1983-08-01

    This report is one of a series that is planned to describe the results of a program undertaken by the Oak Ridge National Laboratory (ORNL) for the US Nuclear Regulatory Commission, Office of Nuclear Regulatory Research, to define, develop, validate, and disseminate a methodology for the quantitative prediction of human reliability in the conduct of maintenance tasks in nuclear power plants (NPPs). ORNL has subcontracted portions of this effort to Applied Psychological Services, Inc. This report on the job analysis of the Instrument and Control technician (NUREG/CR-3274) and a report on the job analysis of the electrician position (NUREG/CR-3275) comprise a part of the initial efforts of the development phase of this program. With the publication of the job analysis of the electrician position, the series of job analyses reports addressing nuclear power plant maintenance personnel will be complete. Subsequent reports addressing model development and validation are planned

  14. A 'hybrid' neutron area survey instrument for the determination of neutron dose quantities in the workplace

    International Nuclear Information System (INIS)

    Tanner, R.J.; Jenkins, R.; Lowe, T.; Silvie, J.; Joyce, M.J.; Winsby, A.; Molinos, C.

    2005-01-01

    Full text: Neutron survey instruments are used routinely to determine the dose rates in areas where persons may be occupationally exposed. With a few exceptions, these instruments generally use a proportional counter with a high thermal neutron response located in a moderating sphere of CH 2 . The moderating sphere in such designs contains a thermal neutron absorber to reduce the over-response to thermal and intermediate energy neutrons. However, the commercially available examples of such instruments tend to have strongly energy dependent ambient dose equivalent response characteristics. In particular, they often over-respond in the energy range between 1 eV and 10 keV. A prototype of a novel design has been produced that uses seven detectors located in a moderating sphere of CH 2 , six near the surface to detect thermal and epithermal neutrons, and one in the centre to detect fast neutrons. This has been characterized using a combination of MCNP modelling and measurements to produce an instrument that has improved energy dependence of response characteristics. Additionally, the use of seven detectors offers direction and field hardness information. The design and calibration of the instrument are described and its response in workplaces calculated. (author)

  15. Two new portable survey instruments: the field phoswich detector and the Wee Pee Pee

    International Nuclear Information System (INIS)

    Umbarger, C.J.; Wolf, M.A.

    1978-01-01

    As part of a continuing program to upgrade the health physics survey instrumentation at Los Alamos, we have recently developed two new portable instruments. The first is a fully portable phoswich detector for low energy photons from small amounts of plutonium and americium in the field. The instrument has a background that is 2 to 3 times lower than an equivalent thin NaI detector. The instrument features an aural popper, analogue rate meter, and timer/scaler with liquid crystal display. The second instrument, called the ''Wee Pee Wee,'' is an alpha air proportional probe with complete electronics and readout package mounted on the probe itself. The entire package has a mass of 0.66 kg (1.45 lb) and is carried and operated in one hand. For monitoring shoes and other places where it is difficult to read the count-rate meter, the meter is made detachable for clipping to a shirt pocket, etc. An audio popper, range scales to 100 K cpm, and visual checks for high voltage and battery levels are also included

  16. Hybrid instrument applied to human reliability study in event of loss of external electric power in a nuclear power plant

    International Nuclear Information System (INIS)

    Martins, Eduardo Ferraz

    2015-01-01

    The study projects in highly complex installations involves robust modeling, supported by conceptual and mathematical tools, to carry out systematic research and structured the different risk scenarios that can lead to unwanted events from occurring equipment failures or human errors. In the context of classical modeling, the Probabilistic Safety Analysis (PSA) seeks to provide qualitative and quantitative information about the project particularity and their operational facilities, including the identification of factors or scenarios that contribute to the risk and consequent comparison options for increasing safety. In this context, the aim of the thesis is to develop a hybrid instrument (CPP-HI) innovative, from the integrated modeling techniques of Failure Mode and Effect Analysis (FMEA), concepts of Human Reliability Analysis and Probabilistic Composition of Preferences (PCP). In support of modeling and validation of the CPP-HI, a simulation was performed on a triggering event 'Loss of External Electric Power' - PEEE, in a Nuclear Power plant. The results were simulated in a virtual environment (sensitivity analysis) and are robust to the study of Human Reliability Analysis (HRA) in the context of the PSA. (author)

  17. Test-retest reliability and agreement of the Satisfaction with the Assistive Technology Services (SATS) instrument in two Nordic countries.

    Science.gov (United States)

    Sund, Terje; Iwarsson, Susanne; Anttila, Heidi; Helle, Tina; Brandt, Ase

    2014-07-01

    The purpose of this study was to investigate test-retest reliability, agreement, internal consistency, and floor- and ceiling effects of the Danish and Finnish versions of the Satisfaction with the Assistive Technology Services (SATS) instrument among adult users of powered wheelchairs (PWCs) or powered scooters (scooters). Test-retest design, two telephone interviews 7-18 days apart of 40 informants, with mean age of 67.5 (SD 13.09) years in the Danish; and 54 informants with mean age of 55.6 (SD 12.09) years in the Finnish sample. The intra-class correlation coefficient varied between 0.57 and 0.93 for items in the Danish and between 0.41 and 0.93 in the Finnish sample. The percentage agreement varied between 54.2 and 79.5 for items in the Danish and between 69.2 and 81.1 in the Finnish sample, while the Cronbach's alpha values varied between 0.87 and 0.96 in the two samples. A ceiling effect was found in all items of both samples. This study indicates that the SATS may be reliably administered for telephone interviews among adult PWC and scooter users, and give information about aspects of the service delivery process for quality development improvement purposes. Further psychometric testing of the SATS is required.

  18. Functional leg length discrepancy between theories and reliable instrumental assessment: a study about newly invented NPoS system.

    Science.gov (United States)

    Mahmoud, Asmaa; Abundo, Paolo; Basile, Luisanna; Albensi, Caterina; Marasco, Morena; Bellizzi, Letizia; Galasso, Franco; Foti, Calogero

    2017-01-01

    In spite the instinct social&financial impact of Leg Length Discrepancy (LLD), controversial and conflicting results still exist regarding a reliable assessment/correction method. For proper management it's essential to discriminate between anatomical&functional Leg Length Discrepancy (FLLD). With the newly invented NPoS (New Postural Solution), under the umbrella of the collaboration of PRM Department, Tor Vergata University with Baro Postural Instruments srl, positive results were observed in both measuring& compensating the hemi-pelvic antero-medial rotation in FLLD through personalized bilateral heel raise using two NPoS components: Foot Image System (FIS) and Postural Optimizer System (POS). This led our research interest to test the validity of NPoS as a preliminary step before evaluating its implementations in postural disorders. After clinical evaluation, 4 subjects with FLLD have been assessed by NPoS. Over a period of 2 months, every subject was evaluated 12 times by two different operators, 48 measurements in total, results have been verified in correlation to BTS GaitLab results. Intra-Operator&inter-operator variability analysis showed statistically insignificant differences, while inter-method variability between NPoS and BTS parameters expressed a linear correlation. Results suggest a significant validity of NPoS in assessment&correction of FLLD, with high degree of reproducibility with minimal operator dependency. This can be considered a base for promising clinical implications of NPoS as a reliable cost effective postural assessment/corrective tool. V.

  19. The reliability and validity of the short version of the WHO Quality of Life Instrument in an Arab general population

    International Nuclear Information System (INIS)

    Ohaeri, Jude U; Awadallab, Abdel W

    2009-01-01

    There is rising interest in quality of life (QOL) research in Arabian countries. The aim of this study was to assess in a nationwide sample of Kuwaiti subjects the reliability and validity of the World Health Organization Quality of Life (WHOQOL-BREF), a shorter version of the widely used QOL assessment instrument that comprises 26 items in the domains of physical health, psychological health, social relationships, and the environment. A one-in-three systematic random proportionate sample of consenting Kuwaiti nationals attending large cooperative stores and municipal government offices in the six governorates completed the Arabic translation of the questionnaire. The indices assessed included test-retest reliability, internal consistency, item internal consistency (2C), item discriminant validity (IDV), known-groups and construct validity. There were 3303 participants (44.8% males, 55.2% females, mean age 35.4 years, range 16 to 87 years). The intra-class correlation for the test-retest statistic and the internal consistency values for the full questionnaire and the domains had a Cronbach's alpha > - 0.7. Of the 24 items that constitute the domains, 21 met the 2 C requirement of correlation > - 0.4 with the corresponding domain, while 16 met the IDV criterion of having a higher correlation with their corresponding domain than other domains. Domain scores discriminated significantly between well and sick groups. In the factor analysis, four strong factors emerged with the same construct as in the WHO report. The Arabic translation of the WHOQOL-BREF has impressive reliability and validity indices. The poor IDV findings are due to the multidimensional nature of the questionnaire. The highly significant validity indices should reassure researchers that the questionnaire represents the same constructs across cultures. Negatively worded items possibly need refinement. (author)

  20. Patient experience and satisfaction with inpatient service: development of short form survey instrument measuring the core aspect of inpatient experience.

    Directory of Open Access Journals (Sweden)

    Eliza L Y Wong

    Full Text Available Patient experience reflects quality of care from the patients' perspective; therefore, patients' experiences are important data in the evaluation of the quality of health services. The development of an abbreviated, reliable and valid instrument for measuring inpatients' experience would reflect the key aspect of inpatient care from patients' perspective as well as facilitate quality improvement by cultivating patient engagement and allow the trends in patient satisfaction and experience to be measured regularly. The study developed a short-form inpatient instrument and tested its ability to capture a core set of inpatients' experiences. The Hong Kong Inpatient Experience Questionnaire (HKIEQ was established in 2010; it is an adaptation of the General Inpatient Questionnaire of the Care Quality Commission created by the Picker Institute in United Kingdom. This study used a consensus conference and a cross-sectional validation survey to create and validate a short-form of the Hong Kong Inpatient Experience Questionnaire (SF-HKIEQ. The short-form, the SF-HKIEQ, consisted of 18 items derived from the HKIEQ. The 18 items mainly covered relational aspects of care under four dimensions of the patient's journey: hospital staff, patient care and treatment, information on leaving the hospital, and overall impression. The SF-HKIEQ had a high degree of face validity, construct validity and internal reliability. The validated SF-HKIEQ reflects the relevant core aspects of inpatients' experience in a hospital setting. It provides a quick reference tool for quality improvement purposes and a platform that allows both healthcare staff and patients to monitor the quality of hospital care over time.

  1. Marine oil pollution and beached bird surveys: the development of a sensitive monitoring instrument

    International Nuclear Information System (INIS)

    Camphuysen, C.J.; Heubeck, M.

    2001-01-01

    One of the most obvious adverse effects of (chronic) pollution of the world's oceans and seas with mineral oil is the mortality of seabirds. Systematic surveys of beachcast corpses of birds ('beached bird surveys') have been used in many parts of the world to document the effect of oil pollution, but particularly so in Western Europe and in parts of North America. In this paper, the history, current schemes, methods and possible (future) use of beached bird surveys are described and discussed, because the value of beached bird surveys has been hotly disputed. Oil pollution is known since the late 19 th century, while the first beached bird surveys were conducted in the 1920s. Due to the amount of man-power needed for these surveys, most beached bird survey programs thrived only through the work of a large number of volunteers. However, most programs have resulted in substantial amounts of high quality data, often covering many consecutive years. One of the main shortcomings of many beached bird survey programs was the emphasis on stranded bird numbers rather than on relative measures, such as oil rates (percentage of corpses oiled of all corpses found). Sources of pollution, particularly so in chronically polluted regions such as the North Sea, the Baltic, the Mediterranean and the waters around Newfoundland, are insufficiently known, but could be studied through a sampling program connected to beached bird surveys. Suggestions for standardization of methods are presented, which could lead to a global and highly sensitive monitoring instrument of marine oil pollution. (Author)

  2. Human factors survey of advanced instrumentation and controls technologies in nuclear plants

    International Nuclear Information System (INIS)

    Carter, R.J.

    1992-01-01

    A survey of advanced instrumentation and controls (I ampersand C) technologies and associated human factors issues in the US and Canadian nuclear industries was carried out by a team from Oak Ridge national laboratory to provide background for the development of regulatory policy, criteria, and guides for review of advanced I ampersand C systems as well as human engineering guidelines for evaluating these systems. The survey found those components of the US nuclear industry surveyed to be quite interested in advanced I ampersand C, but very cautious in implementing such systems in nuclear facilities and power plants. The trend in the facilities surveyed is to experiment cautiously when there is an intuitive advantage or short-term payoff. In the control room, the usual practice is direct substitution of digital and microprocessor-based instruments or systems that are functionally identical to the analog instruments or systems being replaced. The most advanced I ampersand C systems were found in the Canadian CANDU plants, where the newest plant has digital system in almost 100% of its control systems and in over 70% of its plant protection system. The hypothesis that properly 'introducing digital systems increases safety' is supported by the Canadian experience. The performance of these digital systems was achieved using an appropriate quality assurance program for the software development. The ability of digital systems to detect impending failures and initiate a fail-safe action, is a significant safety issue that should be of special interest to every US utility as well as to the US Nuclear Regulatory Commission. (orig.)

  3. Instrument evaluation no. 5. Wallac OY universal radiation survey meter type RD-8

    International Nuclear Information System (INIS)

    White, D.F.; Blundell, D.R.; Callowhill, K.; Iles, W.J.

    1976-05-01

    The Wallace RD-8 is a portable, battery-operated survey meter covering an exposure rate range from 0.01 mR/h to 300 R/h. The instrument was designed specifically for military and civil defence applications and is accordingly of particularly rugged construction and claimed to be both waterproof and shockproof. This instrument is unusual in that it has two internally mounted radiation detectors. An end-window GM tube is used to cover the range from 0.01 to 300 mR/h, and a GM tube covers the range from 0.01 to 300 R/h. Both tubes have energy compensation sheaths for the measurement of photon radiation in the forward direction. Only the first tube permits the measurement of β-radiation. The information is given under the following headings; Facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; summary of performance; calibration procedure; conclusions. (U.K.)

  4. Design and use of concrete pads for the calibration of radiometric survey instrumentation

    International Nuclear Information System (INIS)

    Loevborg, L.

    1984-10-01

    A gamma-ray spectrometer for use in geological exploration possesses four stripping ratios and three window sensitivities which must be determined to make the instrumentation applicable for field assay or airborne measurement of potassium, uranium, and thorium contents in the ground. Survey organizations in many parts of the world perform the instrument calibration using large pads of concrete which simulate a plane ground of known radioelement concentration. Calibration and monitoring trials with twelve facilities in ten countries prove that moisture absorption, radon exhalation, and particle-size effects can offset a radiometric grade assigned to concrete whose aggregate contains an embedded radioactive mineral. These and other calibration problems are discussed from a combined theoretical and practical viewpoint

  5. On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang

    2005-11-01

    This report summarizes technical progress April-September 2005 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Due to the difficulties described on the last report, field testing of the BPDI system has not continued to date. However, we have developed an alternative high temperature sensing solution, which is described in this report. The sensing system will be installed and tested at TECO's Polk Power Station. Following a site visit in June 2005, our efforts have been focused on preparing for that field test, including he design of the sensor mechanical packaging, sensor electronics, the data transfer module, and the necessary software codes to accommodate this application.. We are currently ready to start sensor fabrication.

  6. The Italian version of cognitive function instrument (CFI): reliability and validity in a cohort of healthy elderly.

    Science.gov (United States)

    Chipi, Elena; Frattini, Giulia; Eusebi, Paolo; Mollica, Anita; D'Andrea, Katia; Russo, Mirella; Bernardelli, Alice; Montanucci, Chiara; Luchetti, Elisa; Calabresi, Paolo; Parnetti, Lucilla

    2018-01-01

    The Alzheimer's disease Cooperative Study (ADCS)-Cognitive Function Instrument (CFI) is a 14-item questionnaire administered to the subject and the referent, aimed at detecting early changes in cognitive and functional abilities in individuals without clinical impairment. It is used for monitoring annual variations in cognitive functioning in prevention trials. The aim of the present study was to validate the Italian version of the CFI. A consecutive series of 257 functionally independent subjects was recruited among relatives of patients or as volunteers. They were administered CFI and global cognition measurements: Mini-Mental Status Examination (MMSE) and Repeatable Battery for the Assessment of Neuropsychological Status (RBANS). The reliability and criterion validity were comparable to the original in both self- and partner-report. Similarly to what reported in the original version, we found a corrected item-total correlation ranging between 0.38 and 0.54 in self-report and between 0.33 and 0.64 in partner-report. Cronbach's α was 0.77 (95% CI 0.72-0.83) in self-report and 0.78 (95% CI 0.73-0.84) in partner-report. Total partner- and self-report scores were significantly correlated (rS = 0.31, p reliability and validity of the Italian version of CFI. In order to definitely propose the use of CFI for tracking longitudinal changes of cognitive and functional abilities in subjects without clinical impairment, data from the follow-up of this cohort are needed.

  7. The reliability, validity and responsiveness of the Thai version of Systemic Lupus Erythematosus Quality of Life (SLEQOL-TH) instrument.

    Science.gov (United States)

    Kasitanon, N; Wangkaew, S; Puntana, S; Sukitawut, W; Leong, K P; Louthrenoo, W

    2013-03-01

    The English version of the Systemic Lupus Erythematosus Quality of Life Questionnaire (SLEQOL) is a validated disease-specific quality of life instrument. The aim of this study was to evaluate the psychometric properties of the Thai version of the SLEQOL (SLEQOL-TH). Two independent translators translated the SLEQOL into Thai. The back translation of this version was performed by two other independent translators. The final version, SLEQOL-TH, was completed after resolving the discrepancies revealed by the back translation. One hundred and nine patients with SLE were enrolled to test the reliability, construct validity, floor and ceiling effects, and sensitivity to the changes of the SLEQOL-TH at six months. The differential item functioning (DIF) between the Thai and English versions was analyzed using the partial gamma. The internal consistency of the SLEQOL-TH was satisfactory with the overall Cronbach's alpha of 0.86. The test-retest reliability of the SLEQOL-TH was acceptable with the intra-class correlation coefficient of 0.86. Low correlations between the SLEQOL-TH and SLEDAI were observed. The total score of the SLEQOL-TH was moderately responsive to changes in quality of life, with a standardized response mean of 0.50. When comparing the SLEQOL-TH from Thai SLE patients with the original SLEQOL version obtained from Singapore SLE patients, 11 out of 40 items showed a moderate to large DIF. The SLEQOL-TH has acceptable psychometric properties and shows construct validity. In comparison with the English version of SLEQOL, there are some items that showed DIF. The applicability of the SLEQOL-TH in real-life clinical practice and clinical trials needs to be determined.

  8. Report of the Survey on the Design Review of New Reactor Applications. Volume 1 - Instrumentation and Control

    International Nuclear Information System (INIS)

    Downey, Steven

    2014-06-01

    At the tenth meeting of the CNRA Working Group on the Regulation of New Reactors (WGRNR) in March 2013, the members agreed to present the responses to the Second Phase, or Design Phase, of the Licensing Process Survey as a multi-volume text. As such, each report will focus on one of the eleven general technical categories covered in the survey. The general technical categories were selected to conform to the topics covered in the International Atomic Energy Agency (IAEA) Safety Guide GS-G-4.1. This report, which is the first volume, provides a discussion of the survey responses related to Instrumentation and Control (I and C). The Instrumentation and Control category includes the twelve following technical topics: Reactor trip system, actuation systems for Engineered Safety Features (ESF), safe shutdown system, safety-related display instrumentation, information and interlock systems important to safety, controls systems, main control room, supplementary control room, diverse I and C systems, data communication systems, software reliability and cyber-security. For each technical topic, the member countries described the information provided by the applicant, the scope and level of detail of the technical review, the technical basis for granting regulatory authorisation, the skill sets required and the Level of effort needed to perform the review. Based on a comparison of the information provided in response to the survey, the following observations were made: - Among the regulatory organisations that responded to the survey, there are similarities in the design information provided by an applicant. In most countries, the design information provided by an applicant includes, but is not limited to, a description of the I and C system design and functions, a description of the verification and validation programmes, and provisions for analysis, testing, and inspection of various I and C systems. - In addition to the regulations, it is a common practice for countries

  9. Quality of persian addiction websites: a survey based on silberg, discern and wqet instruments (2011).

    Science.gov (United States)

    Zahedi, Razieh; Taheri, Behjat; Shahrzadi, Leila; Tazhibi, Mehdi; Ashrafi-rizi, Hasan

    2013-03-01

    Nowadays, World Wide Web is an accessible and widespread resource to attain medical information. So physicians and health institutions try to inform patients about different domains of medicine through Web. Addiction is a noteworthy subject in medicine and a controversial issue among them. However, quality of health information on the internet is doubtful. The objective of this study is to determine the quality of Persian addiction websites to offer recommendation for their improvement. This was survey and an applied study that the study population was all Persian addiction websites. Sample of this study was 28 Persian addiction website which were chosen by searching Persian equivalences of 7 key terms (addiction, addict, addiction center, drug, treatment of addiction, recovery of addiction, addiction withdrawal) into the Google and Yahoo search engines. Finally, the websites were ranked based on the Silberg, DISCERN and WQET instruments. Data were analyzed with Excel software using descriptive statistics. The overall mean of websites in Silberg, DISCERN and WQET instruments were 1.42, 41.89, 64.57. Also the results showed that "Unit of Substance Abuse Treatment" belonging to Mashhad University of Medical Sciences was ranked first based on the Silberg, DISCERN and WQET instruments. 5 (from total of 9), 60 (from total of 80) and 82 (from total of normalized grade 82) were grades for this website for these instruments respectively. It showed that the quality of Persian websites according to Silberg, DISCERN and WQET instruments was "low", "more than half" and "very good" respectively. Not assigning date of entering data, author names, and references of information (authority) were most important missing characteristics of these websites. In addition, lack of interactive opportunities like chat rooms was another problem that leads to dissatisfaction of users.

  10. Human and organisational factors influencing the reliability of non-destructive testing. An international literary survey

    International Nuclear Information System (INIS)

    Kettunen, J.; Norros, L.

    1996-04-01

    The aim of the study is to chart human and organisational factors influencing the reliability of non-destructive testing (NDT). The emphasis will be in ultrasonic testing (UT) and in the planning and execution of in-service inspections during nuclear power plant maintenance outages. Being a literary survey this study is mainly based on the foreign and domestic research available on the topic. In consequence, the results presented in this report reflect the ideas of international research community. In addition to this, Finnish nuclear power plant operators (Imatran Voima Oy and Teollisuuden Voima Oy), independent inspection organisations and the Finnish Centre for Radiation and Nuclear Safety have provided us with valuable information on NDT theory and practice. Especially, a kind of 'big picture' of non-destructive testing has been pursued in the study. (6 figs., 2 tabs.)

  11. Reliability and construct validity of the Instrument to Measure the Impact of Valve Heart Disease on the Patient's Daily Life.

    Science.gov (United States)

    Anjos, Daniela Brianne Martins Dos; Rodrigues, Roberta Cunha Matheus; Padilha, Kátia Melissa; Pedrosa, Rafaela Batista Dos Santos; Gallani, Maria Cecília Bueno Jayme

    2016-12-19

    evaluate the practicality, acceptability and the floor and ceiling effects, estimate the reliability and verify the convergent construct's validity with the instrument called the Heart Valve Disease Impact on daily life (IDCV) of the valve disease in patients with mitral and or aortic heart valve disease. data was obtained from 86 heart valve disease patients through 3 phases: a face to face interview for a socio-demographic and clinic characterization and then other two done through phone calls of the interviewed patients for application of the instrument (test and repeat test). as for the practicality and acceptability, the instrument was applied with an average time of 9,9 minutes and with 110% of responses, respectively. Ceiling and floor effects observed for all domains, especially floor effect. Reliability was tested using the test - repeating pattern to give evidence of temporal stability of the measurement. Significant negative correlations with moderate to strong magnitude were found between the score of the generic question about the impact of the disease and the scores of IDCV, which points to the validity of the instrument convergent construct. the instrument to measure the impact of valve heart disease on the patient's daily life showed evidence of reliability and validity when applied to patients with heart valve disease. avaliar a praticabilidade, aceitabilidade e os efeitos teto e chão, estimar a confiabilidade e verificar a validade de construto convergente do Instrumento para Mensuração do Impacto da Doença no Cotidiano do Valvopata em pacientes com valvopatia mitral e/ou aórtica. dados foram obtidos junto a 86 pacientes valvopatas por meio de três etapas: uma entrevista presencial para caracterização sociodemográfica e clínica e as duas outras realizadas por meio de contato telefônico para as aplicações do instrumento (Teste e teste de repetição). quanto à praticabilidade e aceitabilidade, o instrumento foi aplicado com tempo m

  12. The Gaia spectrophotometric standard stars survey: II. Instrumental effects of six ground-based observing campaigns

    Science.gov (United States)

    Altavilla, G.; Marinoni, S.; Pancino, E.; Galleti, S.; Ragaini, S.; Bellazzini, M.; Cocozza, G.; Bragaglia, A.; Carrasco, J. M.; Castro, A.; Di Fabrizio, L.; Federici, L.; Figueras, F.; Gebran, M.; Jordi, C.; Masana, E.; Schuster, W.; Valentini, G.; Voss, H.

    2015-08-01

    The Gaia SpectroPhotometric Standard Stars (SPSS) survey started in 2006, was awarded almost 450 observing nights and accumulated almost 100 000 raw data frames with both photometric and spectroscopic observations. Such large observational effort requires careful, homogeneous, and automatic data reduction and quality control procedures. In this paper, we quantitatively evaluate instrumental effects that might have a significant (i.e., ≥ 1 %) impact on the Gaia SPSS flux calibration. The measurements involve six different instruments, monitored over the eight years of observations dedicated to the Gaia flux standards campaigns: DOLORES@TNG in La Palma, EFOSC2@NTT and ROSS@REM in La Silla, CAFOS@2.2 m in Calar Alto, BFOSC@Cassini in Loiano, and LaRuca@1.5 m in San Pedro Mártir. We examine and quantitatively evaluate the following effects: CCD linearity and shutter times, calibration frames stability, lamp flexures, second order contamination, light polarization, and fringing. We present methods to correct for the relevant effects which can be applied to a wide range of observational projects at similar instruments. Based on data obtained with BFOSC@Cassini in Loiano, Italy; EFOSC2@NTT in La Silla, Chile; DOLORES@TNG in La Palma, Spain; CAFOS@2.2 m in Calar Alto, Spain; LaRuca@1.5 m in San Pedro Mártir, Mexico (see acknowledgements for more details).

  13. Validity and reliability of a Malay version of the Lawton instrumental activities of daily living scale among the Malay speaking elderly in Malaysia.

    Science.gov (United States)

    Kadar, Masne; Ibrahim, Suhaili; Razaob, Nor Afifi; Chai, Siaw Chui; Harun, Dzalani

    2018-02-01

    The Lawton Instrumental Activities of Daily Living Scale is a tool often used to assess independence among elderly at home. Its suitability to be used with the elderly population in Malaysia has not been validated. This current study aimed to assess the validity and reliability of the Lawton Instrumental Activities of Daily Living Scale - Malay Version to Malay speaking elderly in Malaysia. This study was divided into three phases: (1) translation and linguistic validity involving both forward and backward translations; (2) establishment of face validity and content validity; and (3) establishment of reliability involving inter-rater, test-retest and internal consistency analyses. Data used for these analyses were obtained by interviewing 65 elderly respondents. Percentages of Content Validity Index for 4 criteria were from 88.89 to 100.0. The Cronbach α coefficient for internal consistency was 0.838. Intra-class Correlation Coefficient of inter-rater reliability and test-retest reliability was 0.957 and 0.950 respectively. The result shows that the Lawton Instrumental Activities of Daily Living Scale - Malay Version has excellent reliability and validity for use with the Malay speaking elderly people in Malaysia. This scale could be used by professionals to assess functional ability of elderly who live independently in community. © 2018 Occupational Therapy Australia.

  14. Reliability of Nationwide Prevalence Estimates of Dementia: A Critical Appraisal Based on Brazilian Surveys.

    Directory of Open Access Journals (Sweden)

    Flávio Chaimowicz

    Full Text Available The nationwide dementia prevalence is usually calculated by applying the results of local surveys to countries' populations. To evaluate the reliability of such estimations in developing countries, we chose Brazil as an example. We carried out a systematic review of dementia surveys, ascertained their risk of bias, and present the best estimate of occurrence of dementia in Brazil.We carried out an electronic search of PubMed, Latin-American databases, and a Brazilian thesis database for surveys focusing on dementia prevalence in Brazil. The systematic review was registered at PROSPERO (CRD42014008815. Among the 35 studies found, 15 analyzed population-based random samples. However, most of them utilized inadequate criteria for diagnostics. Six studies without these limitations were further analyzed to assess the risk of selection, attrition, outcome and population bias as well as several statistical issues. All the studies presented moderate or high risk of bias in at least two domains due to the following features: high non-response, inaccurate cut-offs, and doubtful accuracy of the examiners. Two studies had limited external validity due to high rates of illiteracy or low income. The three studies with adequate generalizability and the lowest risk of bias presented a prevalence of dementia between 7.1% and 8.3% among subjects aged 65 years and older. However, after adjustment for accuracy of screening, the best available evidence points towards a figure between 15.2% and 16.3%.The risk of bias may strongly limit the generalizability of dementia prevalence estimates in developing countries. Extrapolations that have already been made for Brazil and Latin America were based on a prevalence that should have been adjusted for screening accuracy or not used at all due to severe bias. Similar evaluations regarding other developing countries are needed in order to verify the scope of these limitations.

  15. Survey of bayesian belif nets for quantitative reliability assessment of safety critical software used in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Eom, H.S.; Sung, T.Y.; Jeong, H.S.; Park, J.H.; Kang, H.G.; Lee, K

    2001-03-01

    As part of the Probabilistic Safety Assessment of safety grade digital systems used in Nuclear Power plants research, measures and methodologies applicable to quantitative reliability assessment of safety critical software were surveyed. Among the techniques proposed in the literature we selected those which are in use widely and investigated their limitations in quantitative software reliability assessment. One promising methodology from the survey is Bayesian Belief Nets (BBN) which has a formalism and can combine various disparate evidences relevant to reliability into final decision under uncertainty. Thus we analyzed BBN and its application cases in digital systems assessment area and finally studied the possibility of its application to the quantitative reliability assessment of safety critical software.

  16. Survey of bayesian belif nets for quantitative reliability assessment of safety critical software used in nuclear power plants

    International Nuclear Information System (INIS)

    Eom, H. S.; Sung, T. Y.; Jeong, H. S.; Park, J. H.; Kang, H. G.; Lee, K.

    2001-03-01

    As part of the Probabilistic Safety Assessment of safety grade digital systems used in Nuclear Power plants research, measures and methodologies applicable to quantitative reliability assessment of safety critical software were surveyed. Among the techniques proposed in the literature we selected those which are in use widely and investigated their limitations in quantitative software reliability assessment. One promising methodology from the survey is Bayesian Belief Nets (BBN) which has a formalism and can combine various disparate evidences relevant to reliability into final decision under uncertainty. Thus we analyzed BBN and its application cases in digital systems assessment area and finally studied the possibility of its application to the quantitative reliability assessment of safety critical software

  17. On-line instrument for control of water and steam quality at energy production plants - a market survey

    International Nuclear Information System (INIS)

    Fahlgren, N.; Persson, F.

    1988-10-01

    Instruments for on-line measuring are today available for all water analyses that can be of intrerest in power stations. For some of the analyses instruments have been in operation for many years e.g. for determination of silica, sodium and oxygen. For other analyses no instruments or only a few have been in operation. Many instruments are developed under the last years. Operation experiences for many instruments are therefore limited. For mostly all instruments, also for instruments that have been in operation a long time, operation experiences from the same type of instruments differ from plant to plant. The reson is that most of the instruments need daily or weekly maintenance and that has not always been aquainted. The time for necessary maintenance is however not so long that it is deterrent. The time for necessary maintenance for an instrument is normally 1-2 hours a week. On-line measuring, improve supervision and reliability of service and are therefore to recommend in both big and small plants. In small plants it is very important to have a good supervision of pH-value, conductivity, harness and the content of oxygen in feed water. (authors)

  18. The 2010 American college of rheumatology fibromyalgia survey diagnostic criteria and symptom severity scale is a valid and reliable tool in a French speaking fibromyalgia cohort

    Directory of Open Access Journals (Sweden)

    Fitzcharles Mary-Ann

    2012-09-01

    Full Text Available Abstract Background Fibromyalgia (FM is a pain condition with associated symptoms contributing to distress. The Fibromyalgia Survey Diagnostic Criteria and Severity Scale (FSDC is a patient-administered questionnaire assessing diagnosis and symptom severity. Locations of body pain measured by the Widespread Pain Index (WPI, and the Symptom Severity scale (SS measuring fatigue, unrefreshing sleep, cognitive and somatic complaints provide a score (0–31, measuring a composite of polysymptomatic distress. The reliability and validity of the translated French version of the FSDC was evaluated. Methods The French FSDC was administered twice to 73 FM patients, and was correlated with measures of symptom status including: Fibromyalgia Impact Questionnaire (FIQ, Health Assessment Questionnaire (HAQ, McGill Pain Questionnaire (MPQ, and a visual analogue scale (VAS for global severity and pain. Test-retest reliability, internal consistency, and construct validity were evaluated. Results Test-retest reliability was between .600 and .888 for the 25 single items of the FSDC, and .912 for the total FSDC, with all correlations significant (p  Conclusions The French FSDC is a valid instrument in French FM patients with reliability and construct validity. It is easily completed, simple to score, and has the potential to become the standard for measurement of polysymptomatic distress in FM.

  19. Development and evaluation of a new survey instrument to measure the quality of colorectal cancer screening decisions.

    Science.gov (United States)

    Sepucha, Karen R; Feibelmann, Sandra; Cosenza, Carol; Levin, Carrie A; Pignone, Michael

    2014-08-20

    Guidelines for colorectal cancer screening recommend that patients be informed about options and be able to select preferred method of screening; however, there are no existing measures available to assess whether this happens. Colorectal Cancer Screening Decision Quality Instrument (CRC-DQI) includes knowledge items and patients' goals and concerns. Items were generated through literature review and qualitative work with patients and providers. Hypotheses relating to the acceptability, feasibility, discriminant validity and retest reliability of the survey were examined using data from three studies: (1) 2X2 randomized study of participants recruited online, (2) cross-sectional sample of patients recruited in community health clinics, and (3) cross-sectional sample of providers recruited from American Medical Association Master file. 338 participants were recruited online, 94 participants were recruited from community health centers, and 115 physicians were recruited. The CRC-DQI was feasible and acceptable with low missing data and high response rates for both online and paper-based administrations. The knowledge score was able to discriminate between those who had seen a decision aid or not (84% vs. 64%, p quality decisions about colon cancer screening.

  20. reliability reliability

    African Journals Online (AJOL)

    eobe

    Corresponding author, Tel: +234-703. RELIABILITY .... V , , given by the code of practice. However, checks must .... an optimization procedure over the failure domain F corresponding .... of Concrete Members based on Utility Theory,. Technical ...

  1. Measuring determinants of career satisfaction of anesthesiologists: validation of a survey instrument.

    Science.gov (United States)

    Afonso, Anoushka M; Diaz, James H; Scher, Corey S; Beyl, Robbie A; Nair, Singh R; Kaye, Alan David

    2013-06-01

    To measure the parameter of job satisfaction among anesthesiologists. Survey instrument. Academic anesthesiology departments in the United States. 320 anesthesiologists who attended the annual meeting of the ASA in 2009 (95% response rate). The anonymous 50-item survey collected information on 26 independent demographic variables and 24 dependent ranked variables of career satisfaction among practicing anesthesiologists. Mean survey scores were calculated for each demographic variable and tested for statistically significant differences by analysis of variance. Questions within each domain that were internally consistent with each other within domains were identified by Cronbach's alpha ≥ 0.7. P-values ≤ 0.05 were considered statistically significant. Cronbach's alpha analysis showed strong internal consistency for 10 dependent outcome questions in the practice factor-related domain (α = 0.72), 6 dependent outcome questions in the peer factor-related domain (α = 0.71), and 8 dependent outcome questions in the personal factor-related domain (α = 0.81). Although age was not a variable, full-time status, early satisfaction within the first 5 years of practice, working with respected peers, and personal choice factors were all significantly associated with anesthesiologist job satisfaction. Improvements in factors related to job satisfaction among anesthesiologists may lead to higher early and current career satisfaction. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Reliability of a computer and Internet survey (Computer User Profile) used by adults with and without traumatic brain injury (TBI).

    Science.gov (United States)

    Kilov, Andrea M; Togher, Leanne; Power, Emma

    2015-01-01

    To determine test-re-test reliability of the 'Computer User Profile' (CUP) in people with and without TBI. The CUP was administered on two occasions to people with and without TBI. The CUP investigated the nature and frequency of participants' computer and Internet use. Intra-class correlation coefficients and kappa coefficients were conducted to measure reliability of individual CUP items. Descriptive statistics were used to summarize content of responses. Sixteen adults with TBI and 40 adults without TBI were included in the study. All participants were reliable in reporting demographic information, frequency of social communication and leisure activities and computer/Internet habits and usage. Adults with TBI were reliable in 77% of their responses to survey items. Adults without TBI were reliable in 88% of their responses to survey items. The CUP was practical and valuable in capturing information about social, leisure, communication and computer/Internet habits of people with and without TBI. Adults without TBI scored more items with satisfactory reliability overall in their surveys. Future studies may include larger samples and could also include an exploration of how people with/without TBI use other digital communication technologies. This may provide further information on determining technology readiness for people with TBI in therapy programmes.

  3. The Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH): an observational instrument for assessing the physical environment of institutional settings for persons with dementia.

    Science.gov (United States)

    Sloane, Philip D; Mitchell, C Madeline; Weisman, Gerald; Zimmerman, Sheryl; Foley, Kristie M Long; Lynn, Mary; Calkins, Margaret; Lawton, M Powell; Teresi, Jeanne; Grant, Leslie; Lindeman, David; Montgomery, Rhonda

    2002-03-01

    To develop an observational instrument that describes the ability of physical environments of institutional settings to address therapeutic goals for persons with dementia. A National Institute on Aging workgroup identified and subsequently revised items that evaluated exit control, maintenance, cleanliness, safety, orientation/cueing, privacy, unit autonomy, outdoor access, lighting, noise, visual/tactile stimulation, space/seating, and familiarity/homelikeness. The final instrument contains 84 discrete items and one global rating. A summary scale, the Special Care Unit Environmental Quality Scale (SCUEQS), consists of 18 items. Lighting items were validated using portable light meters. Concurrent criterion validation compared SCUEQS scores with the Professional Environmental Assessment Protocol (PEAP). Interrater kappa statistics for 74% of items were above.60. For another 10% of items, kappas could not be calculated due to empty cells, but interrater agreement was above 80%. The SCUEQS demonstrated an interrater reliability of.93, a test--retest reliability of.88, and an internal consistency of.81--.83. Light meter ratings correlated significantly with the Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH) lighting items (r =.29--.38, p =.01--.04), and the SCUEQS correlated significantly with global PEAP ratings (r =.52, p TESS-NH efficiently assesses discrete elements of the physical environment and has strong reliability and validity. The SCUEQS provides a quantitative measure of environmental quality in institutional settings.

  4. A survey on the human reliability analysis methods for the design of Korean next generation reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Hee; Lee, J. W.; Park, J. C.; Kwack, H. Y.; Lee, K. Y.; Park, J. K.; Kim, I. S.; Jung, K. W

    2000-03-01

    Enhanced features through applying recent domestic technologies may characterize the safety and efficiency of KNGR(Korea Next Generation Reactor). Human engineered interface and control room environment are expected to be beneficial to the human aspects of KNGR design. However, since the current method for human reliability analysis is not up to date after THERP/SHARP, it becomes hard to assess the potential of human errors due to both of the positive and negative effect of the design changes in KNGR. This is a state of the art report on the human reliability analysis methods that are potentially available for the application to the KNGR design. We surveyed every technical aspects of existing HRA methods, and compared them in order to obtain the requirements for the assessment of human error potentials within KNGR design. We categorized the more than 10 methods into the first and the second generation according to the suggestion of Dr. Hollnagel. THERP was revisited in detail. ATHEANA proposed by US NRC for an advanced design and CREAM proposed by Dr. Hollnagel were reviewed and compared. We conclude that the key requirements might include the enhancement in the early steps for human error identification and the quantification steps with considerations of more extended error shaping factors over PSFs(performance shaping factors). The utilization of the steps and approaches of ATHEANA and CREAM will be beneficial to the attainment of an appropriate HRA method for KNGR. However, the steps and data from THERP will be still maintained because of the continuity with previous PSA activities in KNGR design.

  5. A survey on the human reliability analysis methods for the design of Korean next generation reactor

    International Nuclear Information System (INIS)

    Lee, Yong Hee; Lee, J. W.; Park, J. C.; Kwack, H. Y.; Lee, K. Y.; Park, J. K.; Kim, I. S.; Jung, K. W.

    2000-03-01

    Enhanced features through applying recent domestic technologies may characterize the safety and efficiency of KNGR(Korea Next Generation Reactor). Human engineered interface and control room environment are expected to be beneficial to the human aspects of KNGR design. However, since the current method for human reliability analysis is not up to date after THERP/SHARP, it becomes hard to assess the potential of human errors due to both of the positive and negative effect of the design changes in KNGR. This is a state of the art report on the human reliability analysis methods that are potentially available for the application to the KNGR design. We surveyed every technical aspects of existing HRA methods, and compared them in order to obtain the requirements for the assessment of human error potentials within KNGR design. We categorized the more than 10 methods into the first and the second generation according to the suggestion of Dr. Hollnagel. THERP was revisited in detail. ATHEANA proposed by US NRC for an advanced design and CREAM proposed by Dr. Hollnagel were reviewed and compared. We conclude that the key requirements might include the enhancement in the early steps for human error identification and the quantification steps with considerations of more extended error shaping factors over PSFs(performance shaping factors). The utilization of the steps and approaches of ATHEANA and CREAM will be beneficial to the attainment of an appropriate HRA method for KNGR. However, the steps and data from THERP will be still maintained because of the continuity with previous PSA activities in KNGR design

  6. Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG Test in Patients with Parkinson's Disease.

    Directory of Open Access Journals (Sweden)

    Rob C van Lummel

    Full Text Available The "Timed Up and Go" (TUG is a widely used measure of physical functioning in older people and in neurological populations, including Parkinson's Disease. When using an inertial sensor measurement system (instrumented TUG [iTUG], the individual components of the iTUG and the trunk kinematics can be measured separately, which may provide relevant additional information.The aim of this study was to determine intra-rater, inter-rater and test-retest reliability of the iTUG in patients with Parkinson's Disease.Twenty eight PD patients, aged 50 years or older, were included. For the iTUG the DynaPort Hybrid (McRoberts, The Hague, The Netherlands was worn at the lower back. The device measured acceleration and angular velocity in three directions at a rate of 100 samples/s. Patients performed the iTUG five times on two consecutive days. Repeated measurements by the same rater on the same day were used to calculate intra-rater reliability. Repeated measurements by different raters on the same day were used to calculate intra-rater and inter-rater reliability. Repeated measurements by the same rater on different days were used to calculate test-retest reliability.Nineteen ICC values (15% were ≥ 0.9 which is considered as excellent reliability. Sixty four ICC values (49% were ≥ 0.70 and < 0.90 which is considered as good reliability. Thirty one ICC values (24% were ≥ 0.50 and < 0.70, indicating moderate reliability. Sixteen ICC values (12% were ≥ 0.30 and < 0.50 indicating poor reliability. Two ICT values (2% were < 0.30 indicating very poor reliability.In conclusion, in patients with Parkinson's disease the intra-rater, inter-rater, and test-retest reliability of the individual components of the instrumented TUG (iTUG was excellent to good for total duration and for turning durations, and good to low for the sub durations and for the kinematics of the SiSt and StSi. The results of this fully automated analysis of instrumented TUG movements

  7. Reliability and validity of a survey to measure bowel function and quality of life in long-term rectal cancer survivors.

    Science.gov (United States)

    Wendel, Christopher S; Grant, Marcia; Herrinton, Lisa; Temple, Larissa K F; Hornbrook, Mark C; McMullen, Carmit K; Bulkley, Joanna E; Altschuler, Andrea; Krouse, Robert S

    2014-12-01

    Examination of reliability and validity of a specialized health-related quality of life questionnaire for rectal cancer (RC) survivors (≥5 years post-diagnosis). We mailed 1,063 Kaiser Permanente (KP) RC survivors (313 ostomy and 750 anastomosis) a questionnaire containing the Modified City of Hope Quality of Life-Ostomy (mCOH-QOL-O), SF-12v2, Duke-UNC Functional Social Support Questionnaire (FSSQ), and Memorial Sloan-Kettering Cancer Center Bowel Function Index (BFI). We adapted certain BFI items for use by subjects with intestinal ostomies. We evaluated reliability for all instruments with inter-item correlations and Cronbach's alpha. We assessed construct validity only for the BFI in the ostomy group, because such use has not been reported. The overall response rate was 60.5 % (577 respondents/953 eligible). Compared with non-responders, participants were on average 2 years younger and more likely non-Hispanic white, resided in educationally non-deprived areas, and had KP membership through a group. The mCOH-QOL-O, SF-12, and FSSQ were found to be highly reliable for RC survivors. In the ostomy group, BFI Urgency/Soilage and Dietary subscales were found to be reliable, but Frequency was not. Factor analysis supported the construct of Urgency/Soilage and Dietary subscales in the ostomy group, although one item had a moderate correlation with all three factors. The BFI also demonstrated good concurrent validity with other instruments in the ostomy group. With possible exception of the BFI Frequency subscale in populations with ostomies, components of our survey can be used for the entire population of RC survivors, no matter whether they received anastomosis or ostomy.

  8. Mechanical Design of NESSI: New Mexico Tech Extrasolar Spectroscopic Survey Instrument

    Science.gov (United States)

    Santoro, Fernando G.; Olivares, Andres M.; Salcido, Christopher D.; Jimenez, Stephen R.; Jurgenson, Colby A.; Hrynevych, Michael A.; Creech-Eakman, Michelle J.; Boston, Penny J.; Schmidt, Luke M.; Bloemhard, Heather; hide

    2011-01-01

    NESSI: the New Mexico Tech Extrasolar Spectroscopic Survey Instrument is a ground-based multi-object spectrograph that operates in the near-infrared. It will be installed on one of the Nasmyth ports of the Magdalena Ridge Observatory (MRO) 2.4-meter Telescope sited in the Magdalena Mountains, about 48 km west of Socorro-NM. NESSI operates stationary to the telescope fork so as not to produce differential flexure between internal opto-mechanical components during or between observations. An appropriate mechanical design allows the instrument alignment to be highly repeatable and stable for both short and long observation timescales, within a wide-range of temperature variation. NESSI is optically composed of a field lens, a field de-rotator, re-imaging optics, an auto-guider and a Dewar spectrograph that operates at LN2 temperature. In this paper we report on NESSI's detailed mechanical and opto-mechanical design, and the planning for mechanical construction, assembly, integration and verification.

  9. Comparing the Psychometric Properties of Two Physical Activity Self-Efficacy Instruments in Urban, Adolescent Girls: Validity, Measurement Invariance, and Reliability

    Science.gov (United States)

    Voskuil, Vicki R.; Pierce, Steven J.; Robbins, Lorraine B.

    2017-01-01

    Aims: This study compared the psychometric properties of two self-efficacy instruments related to physical activity. Factorial validity, cross-group and longitudinal invariance, and composite reliability were examined. Methods: Secondary analysis was conducted on data from a group randomized controlled trial investigating the effect of a 17-week intervention on increasing moderate to vigorous physical activity among 5th–8th grade girls (N = 1,012). Participants completed a 6-item Physical Activity Self-Efficacy Scale (PASE) and a 7-item Self-Efficacy for Exercise Behaviors Scale (SEEB) at baseline and post-intervention. Confirmatory factor analyses for intervention and control groups were conducted with Mplus Version 7.4 using robust weighted least squares estimation. Model fit was evaluated with the chi-square index, comparative fit index, and root mean square error of approximation. Composite reliability for latent factors with ordinal indicators was computed from Mplus output using SAS 9.3. Results: Mean age of the girls was 12.2 years (SD = 0.96). One-third of the girls were obese. Girls represented a diverse sample with over 50% indicating black race and an additional 19% identifying as mixed or other race. Both instruments demonstrated configural invariance for simultaneous analysis of cross-group and longitudinal invariance based on alternative fit indices. However, simultaneous metric invariance was not met for the PASE or the SEEB instruments. Partial metric invariance for the simultaneous analysis was achieved for the PASE with one factor loading identified as non-invariant. Partial metric invariance was not met for the SEEB. Longitudinal scalar invariance was achieved for both instruments in the control group but not the intervention group. Composite reliability for the PASE ranged from 0.772 to 0.842. Reliability for the SEEB ranged from 0.719 to 0.800 indicating higher reliability for the PASE. Reliability was more stable over time in the control

  10. Reliability of the Core Items in the General Social Survey: Estimates from the Three-Wave Panels, 2006–2014

    Directory of Open Access Journals (Sweden)

    Michael Hout

    2016-11-01

    Full Text Available We used standard and multilevel models to assess the reliability of core items in the General Social Survey panel studies spanning 2006 to 2014. Most of the 293 core items scored well on the measure of reliability: 62 items (21 percent had reliability measures greater than 0.85; another 71 (24 percent had reliability measures between 0.70 and 0.85. Objective items, especially facts about demography and religion, were generally more reliable than subjective items. The economic recession of 2007–2009, the slow recovery afterward, and the election of Barack Obama in 2008 altered the social context in ways that may look like unreliability of items. For example, unemployment status, hours worked, and weeks worked have lower reliability than most work-related items, reflecting the consequences of the recession on the facts of peoples lives. Items regarding racial and gender discrimination and racial stereotypes scored as particularly unreliable, accounting for most of the 15 items with reliability coefficients less than 0.40. Our results allow scholars to more easily take measurement reliability into consideration in their own research, while also highlighting the limitations of these approaches.

  11. Preparation of methodology for reliability analysis of selected digital segments of the instrumentation and control systems of NPPs. Pt. 1

    International Nuclear Information System (INIS)

    Hustak, S.; Patrik, M.; Babic, P.

    2000-12-01

    The report is structured as follows: (i) Introduction; (ii) Important notions relating to the safety and dependability of software systems for nuclear power plants (selected notions from IAEA Technical Report No. 397; safety aspects of software application; reliability/dependability aspects of digital systems); (iii) Peculiarities of digital systems and ways to a dependable performance of the required function (failures in the system and principles of defence against them; ensuring resistance of digital systems against failures at various hardware and software levels); (iv) The issue of analytical procedures to assess the safety and reliability of safety-related digital systems (safety and reliability assessment at an early stage of the project; general framework of reliability analysis of complex systems; choice of an appropriate quantitative measure of software reliability); (v) Selected qualitative and quantitative information about the reliability of digital systems; the use of relations between the incidence of various types of faults); and (vi) Conclusions and recommendations. (P.A.)

  12. Reliability of a patient survey assessing cost-related changes in health care use among high deductible health plan enrollees

    Directory of Open Access Journals (Sweden)

    Galbraith Alison A

    2011-05-01

    Full Text Available Abstract Background Recent increases in patient cost-sharing for health care have lent increasing importance to monitoring cost-related changes in health care use. Despite the widespread use of survey questions to measure changes in health care use and related behaviors, scant data exists on the reliability of such questions. Methods We administered a cross-sectional survey to a stratified random sample of families in a New England health plan's high deductible health plan (HDHP with ≥ $500 in annualized out-of-pocket expenditures. Enrollees were asked about their knowledge of their plan, information seeking, behavior change associated with having a deductible, experience of delay in care due in part to cost, and hypothetical delay in care due in part to cost. Initial respondents were mailed a follow-up survey within two weeks of each family returning the original survey. We computed several agreement statistics to measure the test-retest reliability for select questions. We also conducted continuity adjusted chi-square, and McNemar tests in both the original and follow-up samples to measure the degree to which our results could be reproduced. Analyses were stratified by self-reported income. Results The test-retest reliability was moderate for the majority of questions (0.41 - 0.60 and the level of test-retest reliability did not differ substantially across each of the broader domains of questions. The observed proportions of respondents with delayed or foregone pediatric, adult, or any family care were similar when comparing the original and follow-up surveys. In the original survey, respondents in the lower-income group were more likely to delay or forego pediatric care, adult care, or any family care. All of the tests comparing income groups in the follow-up survey produced the same result as in the original survey. Conclusions In this population of HDHP beneficiaries, we found that survey questions concerning plan knowledge, information

  13. Advances in population surveillance for physical activity and sedentary behavior: reliability and validity of time use surveys.

    Science.gov (United States)

    van der Ploeg, Hidde P; Merom, Dafna; Chau, Josephine Y; Bittman, Michael; Trost, Stewart G; Bauman, Adrian E

    2010-11-15

    Many countries conduct regular national time use surveys, some of which date back as far as the 1960s. Time use surveys potentially provide more detailed and accurate national estimates of the prevalence of sedentary and physical activity behavior than more traditional self-report surveillance systems. In this study, the authors determined the reliability and validity of time use surveys for assessing sedentary and physical activity behavior. In 2006 and 2007, participants (n = 134) were recruited from work sites in the Australian state of New South Wales. Participants completed a 2-day time use diary twice, 7 days apart, and wore an accelerometer. The 2 diaries were compared for test-retest reliability, and comparison with the accelerometer determined concurrent validity. Participants with similar activity patterns during the 2 diary periods showed reliability intraclass correlations of 0.74 and 0.73 for nonoccupational sedentary behavior and moderate/vigorous physical activity, respectively. Comparison of the diary with the accelerometer showed Spearman correlations of 0.57-0.59 and 0.45-0.69 for nonoccupational sedentary behavior and moderate/vigorous physical activity, respectively. Time use surveys appear to be more valid for population surveillance of nonoccupational sedentary behavior and health-enhancing physical activity than more traditional surveillance systems. National time use surveys could be used to retrospectively study nonoccupational sedentary and physical activity behavior over the past 5 decades.

  14. Quality of Life among Persons with HIV/AIDS in Iran: Internal Reliability and Validity of an International Instrument and Associated Factors

    Directory of Open Access Journals (Sweden)

    Pedram Razavi

    2012-01-01

    Full Text Available The purpose of this cross-sectional study on 191 HIV/AIDS patient was to prepare the first Persian translation of complete WHOQOL-HIV instrument, evaluate its reliability and validity, and apply it to determine quality of life and its associated factors in Tehran, Iran. Student's t-test was used to compare quality of life between groups. Mean Cronbach’s α of facets in all six domains of instrument were more than 0.6 indicating good reliability. Item/total corrected correlations coefficients had a lower limit of more than 0.5 in all facets except for association between energy and fatigue facet and physical domain. Compared to younger participants, patients older than 35 years had significantly lower scores in overall quality of life (P = 0.003, social relationships (P = 0.021, and spirituality/religion/personal beliefs (P = 0.024. Unemployed patients had significantly lower scores in overall quality of life (P = 0.01, level of independence (P = 0.004, and environment (P = 0.001 compared to employed participants. This study demonstrated that the standard, complete WHOQOL-HIV 120 instrument translated into Farsi and evaluated among Iranian participants provides a reliable and valid basis for future research on quality of life for HIV and other patients in Iran.

  15. Towards the development of an outcome instrument for spinal trauma: an international survey of spinal surgeons.

    Science.gov (United States)

    Oner, F Cumhur; Sadiqi, Said; Lehr, A Mechteld; Dvorak, Marcel F; Aarabi, Bizhan; Chapman, Jens R; Fehlings, Michael G; Kandziora, Frank; Rajasekaran, S; Vaccaro, Alexander R

    2015-01-15

    International web-based survey. To identify the most relevant aspects of human function and health status from the perspective of health care professionals involved in the treatment of spinal trauma patients. There is no universally accepted outcome instrument available that is specifically designed or validated for spinal trauma patients, contributing to controversies related to the optimal treatment and evaluation of many types of spinal injuries. Therefore, the AOSpine Knowledge Forum Trauma aims to develop such an instrument using the International Classification of Functioning, Disability, and Health (ICF) as its basis. Experts from the 5 AOSpine International world regions were asked to give their opinion on the relevance of a compilation of 143 ICF categories for spinal trauma patients on a 3-point scale: "not relevant," "probably relevant," or "definitely relevant." The responses were analyzed using frequency analysis. Possible differences in responses between the 5 world regions were analyzed with the Fisher exact test and descriptive statistics. Of the 895 invited AOSpine International members, 150 (16.8%) participated in this study. A total of 13 (9.1%) ICF categories were identified as definitely relevant by more than 80% of the participants. Most of these categories were related to the ICF component "activities and participation" (n = 8), followed by "body functions" (n = 4), and "body structures" (n = 1). Only some minor regional differences were observed in the pattern of answers. More than 80% of an international group of health care professionals experienced in the clinical care of adult spinal trauma patients indicated 13 of 143 ICF categories as definitely relevant to measure outcomes after spinal trauma. This study creates an evidence base to define a core set of ICF categories for outcome measurement in adult spinal trauma patients.

  16. Validation of the translation of an instrument to measure reliability of written information on treatment choices: a study on attention deficit/hyperactivity disorder (ADHD).

    Science.gov (United States)

    Montoya, A; Llopis, N; Gilaberte, I

    2011-12-01

    DISCERN is an instrument designed to help patients assess the reliability of written information on treatment choices. Originally created in English, there is no validated Spanish version of this instrument. This study seeks to validate the Spanish translation of the DISCERN instrument used as a primary measure on a multicenter study aimed to assess the reliability of web-based information on treatment choices for attention deficit/hyperactivity disorder (ADHD). We used a modified version of a method for validating translated instruments in which the original source-language version is formally compared with the back-translated source-language version. Each item was ranked in terms of comparability of language, similarity of interpretability, and degree of understandability. Responses used Likert scales ranging from 1 to 7, where 1 indicates the best interpretability, language and understandability, and 7 indicates the worst. Assessments were performed by 20 raters fluent in the source language. The Spanish translation of DISCERN, based on ratings of comparability, interpretability and degree of understandability (mean score (SD): 1.8 (1.1), 1.4 (0.9) and 1.6 (1.1), respectively), was considered extremely comparable. All items received a score of less than three, therefore no further revision of the translation was needed. The validation process showed that the quality of DISCERN translation was high, validating the comparable language of the tool translated on assessing written information on treatment choices for ADHD.

  17. A frailty instrument for primary care: findings from the Survey of Health, Ageing and Retirement in Europe (SHARE).

    LENUS (Irish Health Repository)

    Romero-Ortuno, Roman

    2010-01-01

    A frailty paradigm would be useful in primary care to identify older people at risk, but appropriate metrics at that level are lacking. We created and validated a simple instrument for frailty screening in Europeans aged ≥50. Our study is based on the first wave of the Survey of Health, Ageing and Retirement in Europe (SHARE, http:\\/\\/www.share-project.org), a large population-based survey conducted in 2004-2005 in twelve European countries.

  18. Economic instruments for obesity prevention: results of a scoping review and modified delphi survey

    Directory of Open Access Journals (Sweden)

    LaFrance Jeffrey

    2011-10-01

    Full Text Available Abstract Background Comprehensive, multi-level approaches are required to address obesity. One important target for intervention is the economic domain. The purpose of this study was to synthesize existing evidence regarding the impact of economic policies targeting obesity and its causal behaviours (diet, physical activity, and to make specific recommendations for the Canadian context. Methods Arksey and O'Malley's (2005 methodological framework for conducting scoping reviews was adopted for this study and this consisted of two phases: 1 a structured literature search and review, and 2 consultation with experts in the research field through a Delphi survey and an in-person expert panel meeting in April 2010. Results Two key findings from the scoping review included 1 consistent evidence that weight outcomes are responsive to food and beverage prices. The debate on the use of food taxes and subsidies to address obesity should now shift to how best to address practical issues in designing such policies; and 2 very few studies have examined the impact of economic instruments to promote physical activity and clear policy recommendations cannot be made at this time. Delphi survey findings emphasised the relatively modest impact any specific economic instrument would have on obesity independently. Based on empirical evidence and expert opinion, three recommendations were supported. First, to create and implement an effective health filter to review new and current agricultural polices to reduce the possibility that such policies have a deleterious impact on population rates of obesity. Second, to implement a caloric sweetened beverage tax. Third, to examine how to implement fruit and vegetable subsidies targeted at children and low income households. Conclusions In terms of economic interventions, shifting from empirical evidence to policy recommendation remains challenging. Overall, the evidence is not sufficiently strong to provide clear policy

  19. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. III. MEASURES BELOW THE DIFFRACTION LIMIT OF THE WIYN TELESCOPE

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Van Altena, William F.; Howell, Steve B.; Sherry, William H.; Ciardi, David R.

    2011-01-01

    In this paper, we study the ability of CCD- and electron-multiplying-CCD-based speckle imaging to obtain reliable astrometry and photometry of binary stars below the diffraction limit of the WIYN 3.5 m Telescope. We present a total of 120 measures of binary stars, 75 of which are below the diffraction limit. The measures are divided into two groups that have different measurement accuracy and precision. The first group is composed of standard speckle observations, that is, a sequence of speckle images taken in a single filter, while the second group consists of paired observations where the two observations are taken on the same observing run and in different filters. The more recent paired observations were taken simultaneously with the Differential Speckle Survey Instrument, which is a two-channel speckle imaging system. In comparing our results to the ephemeris positions of binaries with known orbits, we find that paired observations provide the opportunity to identify cases of systematic error in separation below the diffraction limit and after removing these from consideration, we obtain a linear measurement uncertainty of 3-4 mas. However, if observations are unpaired or if two observations taken in the same filter are paired, it becomes harder to identify cases of systematic error, presumably because the largest source of this error is residual atmospheric dispersion, which is color dependent. When observations are unpaired, we find that it is unwise to report separations below approximately 20 mas, as these are most susceptible to this effect. Using the final results obtained, we are able to update two older orbits in the literature and present preliminary orbits for three systems that were discovered by Hipparcos.

  20. Chinese version of the Global Youth Tobacco Survey: cross-cultural instrument adaptation

    Directory of Open Access Journals (Sweden)

    Chiou Hung-Yi

    2008-04-01

    Full Text Available Abstract Background Tobacco smoking poses public health concerns because of its high risk for many chronic diseases. Most smokers begin using tobacco in their teens and recent reports indicate that smoking prevalence is climbing among youth. The Global Youth Tobacco Survey (GYTS is a worldwide, school-based, tobacco-specific survey, but cross-cultural differences limit its effectiveness in international studies. Specifically, the GYTS assesses not only the prevalence of smoking, but also tobacco-related attitudes, school curricula, and advertisements, which are culturally influenced. Therefore, we conducted this study to develop a Chinese version of the GYTS for both national surveillance and international comparison. Methods The original English GYTS was translated and back translated using a cross-cultural adaptation process. The comprehensiveness and feasibility of using the Chinese-version GYTS were reviewed by a panel of 6 tobacco-control experts. The understandability and cultural relevance of the Chinese-version GYTS were discussed in a focus group of 5 schoolteachers and 8 students. The expert and focus group feedback was incorporated into a final Chinese version of the GYTS, which was administered to 382 students throughout Taiwan by multi-stage sampling from 10 randomly selected schools. Results The internal consistency (Cronbach's alpha for the GYTS subscales (smoking susceptibility, attitude toward smoking, and media messages about smoking ranged from 0.70 to 0.94. The internal logical agreement of responses ranged from 85.3 to 99.2%. Conclusion The Chinese version of the GYTS has good reliability and validity and can serve as the foundation for international comparison and tobacco control in Chinese-speaking communities.

  1. Upward Transfer in STEM Fields of Study: A New Conceptual Framework and Survey Instrument for Institutional Research

    Science.gov (United States)

    Wang, Xueli

    2016-01-01

    This chapter describes a new conceptual framework that informs research on factors influencing transfer in STEM fields of study from 2-year to 4-year institutions, presents a new survey instrument based on the framework, and offers directions for future research in this area.

  2. The Community College Survey of Men: An Initial Validation of the Instrument's Non-Cognitive Outcomes Construct

    Science.gov (United States)

    Wood, J. \\Luke; Harris, Frank, III.

    2013-01-01

    The purpose of this manuscript is to discuss the utility of the Community College Survey of Men (CCSM[c]), an instrument designed to examine predictors of student success for men in community colleges. The authors highlight initial validation results from a recent pilot of the CCSM[c], with a focus on the non-cognitive outcomes construct employed…

  3. Reliability and Validity of Three Instruments (DSM-IV, CPGI, and PPGM) in the Assessment of Problem Gambling in South Korea.

    Science.gov (United States)

    Back, Ki-Joon; Williams, Robert J; Lee, Choong-Ki

    2015-09-01

    Most research on the assessment, epidemiology, and treatment of problem gambling has occurred in Western jurisdictions. This potentially limits the cross-cultural validity of problem gambling assessment instruments as well as etiological models of problem gambling. The primary objective of the present research was to investigate the reliability and validity of three problem gambling assessment instruments within a South Korean context. A total of 4,330 South Korean adults participated in a comprehensive assessment of their gambling behavior that included the administration of the DSM-IV criteria for pathological gambling (NODS), the Canadian Problem Gambling Index (CPGI), and the Problem and Pathological Gambling Measure (PPGM). Cronbach alpha showed that all three instruments had good internal consistency. Concurrent validity was established by the significant associations observed between scores on the instruments and measures of gambling involvement (number of gambling formats engaged in; frequency of gambling; and gambling expenditure). Most importantly, kappa statistics showed that all instruments have satisfactory classification accuracy against clinical assessment of problem gambling conducted by South Korean clinicians (NODS κ = .66; PPGM κ = .62; CPGI κ = .51). These results confirm that Western-derived operationalizations of problem gambling have applicability in a South Korean setting.

  4. Evaluating the validity and reliability of the V-scale instrument (Turkish version) used to determine nurses' attitudes towards vital sign monitoring.

    Science.gov (United States)

    Ertuğ, Nurcan

    2018-06-01

    The aim of this study was to determine the validity and reliability of the Turkish version of the V-scale, which measures nurses' attitudes towards vital signs monitoring in the detection of clinical deterioration. This validity and reliability study was conducted at a tertiary hospital in Ankara, Turkey, in 2016. A total of 169 ward nurses participated in the study. Exploratory factor analysis, Cronbach's alpha coefficient, and the intraclass correlation coefficient were used to determine the validity and reliability of the scale. A 5-factor, 16-item scale explained 60.823% of the total variance according to the validity analysis. Our version matched the original scale in terms of the number of items and factor structure. Cronbach's alpha coefficient of the Turkish version of the V-scale was 0.764. The test-retest reliability results were 0.855 for the overall intraclass correlation coefficient, and the t-test result was P > 0.05. The V-scale is a reliable and valid instrument to measure Turkish nurses' attitudes towards vital signs monitoring in the detection of clinical deterioration. © 2018 John Wiley & Sons Australia, Ltd.

  5. Personal assistance, income and employment: the spinal injuries survey instrument (SISI) and its application in a sample of people with quadriplegia.

    Science.gov (United States)

    Rowell, D; Connelly, L B

    2008-06-01

    Our aim was to ascertain what effect access to personal care package (PCP) has on the labour market activities of people who have a spinal cord injury (SCI). We developed a new instrument called the spinal injuries survey instrument (SISI). The SISI is a 35-item instrument, which contains items on health, education, employment, along with measures of personal assistance, mobility and psychological attribution style. The SISI was administered, with the Short Form 36 (SF-36) health status instrument, to 250 people with an SCI. The response rate was 72%. A retrospective, matched case-control sampling approach matched individuals who received a PCP, with a cohort who did not. The matching criteria included the site and severity of spinal lesion, age and gender. Although data on the reliability of the instrument are currently lacking, our empirical results are consistent with other studies: (1) mean annual health care costs (AUD$8741) are comparable with Walsh's estimates (2) SF-36 data support Kreuter's contention that mental health is resilient to SCI and (3) a post-injury employment rate of 29.7% corroborates Murphy et al. We present additional data describing income, educational attainment and family support. Our discussion borrows a conceptualization of disability by Sen, that includes both an 'earning handicap' (an impediment to earn income) and a 'conversion handicap' (an impediment to the enjoyment of income). Our application of the SISI provides evidence of both. The labour income of people with quadriplegia is AUD$10,007 per annum, while diminished health status, increased out-of-pocket health expenditure and loss of time suggest a conversion handicap.

  6. The Cognitive Telephone Screening Instrument (COGTEL: A Brief, Reliable, and Valid Tool for Capturing Interindividual Differences in Cognitive Functioning in Epidemiological and Aging Studies

    Directory of Open Access Journals (Sweden)

    Andreas Ihle

    2017-10-01

    Full Text Available Aims: The present study set out to evaluate the psychometric properties of the Cognitive Telephone Screening Instrument (COGTEL in 2 different samples of older adults. Methods: We assessed COGTEL in 116 older adults, with retest after 7 days to evaluate the test-retest reliability. Moreover, we assessed COGTEL in 868 older adults to evaluate convergent validity to the Mini-Mental State Examination (MMSE. Results: Test-retest reliability of the COGTEL total score was good at 0.85 (p < 0.001. Latent variable analyses revealed that COGTEL and MMSE correlated by 0.93 (p < 0.001, indicating convergent validity of the COGTEL. Conclusion: The present analyses suggest COGTEL as a brief, reliable, and valid instrument for capturing interindividual differences in cognitive functioning in epidemiological and aging studies, with the advantage of covering more cognitive domains than traditional screening tools such as the MMSE, as well as differentiating between individual performance levels, in healthy older adults.

  7. The Perceived Personal Control (PPC) questionnaire as an outcome of genetic counseling: reliability and validity of the instrument.

    NARCIS (Netherlands)

    Smets, E.M.A.; Pieterse, A.H.; Aalfs, C.M.; Ausems, M.G.E.M.; Dulmen, A.M. van

    2006-01-01

    The perceived personal control (PPC) questionnaire was developed by Berkenstadt and colleagues as an outcome measure for the evaluation of the process of genetic counseling. The present study aimed to further assess the psychometric properties of a Dutch version of the instrument. Data were used

  8. Inter-rater and test-retest reliability, internal consistency, and factorial structure of the instrument for forensic treatment evaluation

    NARCIS (Netherlands)

    Schuringa, E.; Spreen, M.; Bogaerts, S.

    2014-01-01

    In this study, the Instrument for Forensic Treatment Evaluation (IFTE) is introduced. The IFTE includes 14 dynamic items of the risk assessment scheme HKT-R and eight items specifically related to the treatment of forensic psychiatric patients. The items are divided over three factors: protective

  9. Validity and Reliability of a Parental Self-Efficacy Instrument in the Healthy School Start Prevention Trial of Childhood Obesity

    Science.gov (United States)

    Bohman, Benjamin; Nyberg, Gisela; Sundblom, Elinor; Schäfer Elinder, Liselotte

    2014-01-01

    Introduction: Measures of parental self-efficacy (PSE) for healthy dietary or physical activity (PA) behaviors in children have been used in several studies; however, further psychometric validation of PSE for these behaviors is needed. The purpose of the present study was to evaluate the psychometric properties of a new PSE instrument. Methods:…

  10. A Reliable and Valid Weighted Scoring Instrument for Use in Grading APA-Style Empirical Research Report

    Science.gov (United States)

    Greenberg, Kathleen Puglisi

    2012-01-01

    The scoring instrument described in this article is based on a deconstruction of the seven sections of an American Psychological Association (APA)-style empirical research report into a set of learning outcomes divided into content-, expression-, and format-related categories. A double-weighting scheme used to score the report yields a final grade…

  11. Content Validity and Inter-Rater Reliability of the Halliwick-Concept-Based Instrument "Swimming with Independent Measure"

    Science.gov (United States)

    Srsen, Katja Groleger; Vidmar, Gaj; Pikl, Masa; Vrecar, Irena; Burja, Cirila; Krusec, Klavdija

    2012-01-01

    The Halliwick concept is widely used in different settings to promote joyful movement in water and swimming. To assess the swimming skills and progression of an individual swimmer, a valid and reliable measure should be used. The Halliwick-concept-based Swimming with Independent Measure (SWIM) was introduced for this purpose. We aimed to determine…

  12. NEW INSTRUMENTS FOR SURVEY: ON LINE SOFTWARES FOR 3D RECONTRUCTION FROM IMAGES

    Directory of Open Access Journals (Sweden)

    E. Fratus de Balestrini

    2012-09-01

    Full Text Available 3d scanning technologies had a significant development and have been widely used in documentation of cultural, architectural and archeological heritages. Modern methods of three-dimensional acquiring and modeling allow to represent an object through a digital model that combines visual potentialities of images (normally used for documentation to the accuracy of the survey, becoming at the same time support for the visualization that for metric evaluation of any artefact that have an historical or artistic interest, opening up new possibilities for cultural heritage's fruition, cataloging and study. Despite this development, because of the small catchment area and the 3D laser scanner's sophisticated technologies, the cost of these instruments is very high and beyond the reach of most operators in the field of cultural heritages. This is the reason why they have appeared low-cost technologies or even free, allowing anyone to approach the issues of acquisition and 3D modeling, providing tools that allow to create three-dimensional models in a simple and economical way. The research, conducted by the Laboratory of Photogrammetry of the University IUAV of Venice, of which we present here some results, is intended to figure out whether, with Arc3D, it is possible to obtain results that can be somehow comparable, in therms of overall quality, to those of the laser scanner, and/or whether it is possible to integrate them. They were carried out a series of tests on certain types of objects, models made with Arc3D, from raster images, were compared with those obtained using the point clouds from laser scanner. We have also analyzed the conditions for an optimal use of Arc3D: environmental conditions (lighting, acquisition tools (digital cameras and type and size of objects. After performing the tests described above, we analyzed the patterns generated by Arc3D to check what other graphic representations can be obtained from them: orthophotos and drawings

  13. Item-level psychometrics of the ADL instrument of the Korean National Survey on persons with physical disabilities.

    Science.gov (United States)

    Hong, Ickpyo; Lee, Mi Jung; Kim, Moon Young; Park, Hae Yean

    2017-10-01

    The aim of this study is to investigate the psychometrics of the 12 items of an instrument assessing activities of daily living (ADL) using an item response theory model. A total of 648 adults with physical disabilities and having difficulties in ADLs were retrieved from the 2014 Korean National Survey on People with Disabilities. The psychometric testing included factor analysis, internal consistency, precision, and differential item functioning (DIF) across categories including sex, older age, marital status, and physical impairment area. The sample had a mean age of 69.7 years old (SD = 13.7). The majority of the sample had lower extremity impairments (62.0%) and had at least 2.1 chronic conditions. The instrument demonstrated unidimensional construct and good internal consistency (Cronbach's alpha = 0.95). The instrument precisely estimated person measures within a wide range of theta values (-2.22 logits  5.0%). Our findings indicate that the dressing item would need to be modified to improve its psychometrics. Overall, the ADL instrument demonstrates good psychometrics, and thus, it may be used as a standardized instrument for measuring disability in rehabilitation contexts. However, the findings are limited to adults with physical disabilities. Future studies should replicate psychometric testing for survey respondents with other disorders and for children.

  14. The Validity and Reliability Studies of the Internet Use of Pre-Service English Teachers Survey: A Turkish Context

    Directory of Open Access Journals (Sweden)

    Gülşah Külekçi

    2011-11-01

    Full Text Available As the availability of computers and the Internet in schools and classrooms has grown, so has interest in the extent to which these technologies are being used and for what purposes. Recently there has been many studies on teachers’ use of education technology in their classrooms and schools, the availability of this technology in their classrooms and schools, their training and preparation for their use and the barriers to technology use they encounter. Using the Internet effectively and the success of the Internet utilization is very much related to the users’ attitudes toward the Internet. This study aims at investigating the reliability and the validity of the Internet Use of Pre-service English Teachers Survey modified from the Master Thesis of Sudsuang Yutdhana. The survey contains two subscales as Internet Attitude Scale and Self-perception of Computing Skills. The survey was administered to randomly selected third and fourth year 96 pre – service English Teachers at Dokuz Eylül University Buca, Faculty of Education, Department of English Language Teaching. The results indicated that Internet Use of Pre-service English Teachers Survey (IUPETS is reliable and valid.

  15. [Santa Claus is perceived as reliable and friendly: results of the Danish Christmas 2013 survey].

    Science.gov (United States)

    Amin, Faisal Mohammad; West, Anders Sode; Jørgensen, Carina Sleiborg; Simonsen, Sofie Amalie; Lindberg, Ulrich; Tranum-Jensen, Jørgen; Hougaard, Anders

    2013-12-02

    Several studies have indicated that the population in general perceives doctors as reliable. In the present study perceptions of reliability and kindness attributed to another socially significant archetype, Santa Claus, have been comparatively examined in relation to the doctor. In all, 52 randomly chosen participants were shown a film, where a narrator dressed either as Santa Claus or as a doctor tells an identical story. Structured interviews were then used to assess the subjects' perceptions of reliability and kindness in relation to the narrator's appearance. We found a strong inclination for Santa Claus being perceived as friendlier than the doctor (p = 0.053). However, there was no significant difference in the perception of reliability between Santa Claus and the doctor (p = 0.524). The positive associations attributed to Santa Claus probably cause that he is perceived friendlier than the doctor who may be associated with more serious and unpleasant memories of illness and suffering. Surprisingly, and despite him being an imaginary person, Santa Claus was assessed as being as reliable as the doctor.

  16. Delaware School Climate Survey--Student: Its Factor Structure, Concurrent Validity, and Reliability

    Science.gov (United States)

    Bear, George G.; Gaskins, Clare; Blank, Jessica; Chen, Fang Fang

    2011-01-01

    The Delaware School Climate Survey-Student (DSCS-S) was developed to provide schools with a brief and psychometrically sound student survey for assessing school climate, particularly the dimensions of social support and structure. Confirmatory factor analyses, conducted on a sample of 11,780 students in 85 schools, showed that a bifactor model…

  17. Improving the reliability of Class 1E power distribution to instrumentation and control cabinets on nuclear power plants in the USA. Final report

    International Nuclear Information System (INIS)

    Brennen, M.B.

    1995-09-01

    This study was conducted to explore nontraditional electric power distribution concepts to improve the reliability of uninterruptible power to vital Instrumentation and Control (I and C) cabinets in future US nuclear power plants. The study incorporated comparative technical and economic evaluations of existing and nontraditional uninterruptible power supply (UPS) concepts. All nontraditional distribution concepts were based on available or already emerging components or semiconductor devices. Another purpose of the study was to reduce the cost and complexity of present power distribution and to lower maintenance, replacement, degradation and fault location requirements. The possible reduction of distribution losses, especially during operation under battery power, was also evaluated. The study indicates that direct current distribution at 48 or 125 Vdc levels would have more than an order of magnitude improvement over the reliability of present alternating current supplies at comparable cost. Furthermore, losses under battery power could be reduced significantly with respect to present distribution losses. An inherent advantage of DC distribution is that power transfer from the failed power bus to an operational bus occurs naturally and instantaneously via two simple and reliable semiconductor diodes. AC distribution, on the other hand, requires complex synchronization, decision making and gated semiconductor switching devices for power bus transfer all of which could be eliminated. Some of the concepts presented may also be applied to make existing vital (Class 1E) uninterruptible power supplies in US nuclear plants more reliable

  18. Instrumented static and dynamic balance assessment after stroke using Wii Balance Boards: reliability and association with clinical tests.

    Science.gov (United States)

    Bower, Kelly J; McGinley, Jennifer L; Miller, Kimberly J; Clark, Ross A

    2014-01-01

    The Wii Balance Board (WBB) is a globally accessible device that shows promise as a clinically useful balance assessment tool. Although the WBB has been found to be comparable to a laboratory-grade force platform for obtaining centre of pressure data, it has not been comprehensively studied in clinical populations. The aim of this study was to investigate the measurement properties of tests utilising the WBB in people after stroke. Thirty individuals who were more than three months post-stroke and able to stand unsupported were recruited from a single outpatient rehabilitation facility. Participants performed standardised assessments incorporating the WBB and customised software (static stance with eyes open and closed, static weight-bearing asymmetry, dynamic mediolateral weight shifting and dynamic sit-to-stand) in addition to commonly employed clinical tests (10 Metre Walk Test, Timed Up and Go, Step Test and Functional Reach) on two testing occasions one week apart. Test-retest reliability and construct validity of the WBB tests were investigated. All WBB-based outcomes were found to be highly reliable between testing occasions (ICC  = 0.82 to 0.98). Correlations were poor to moderate between WBB variables and clinical tests, with the strongest associations observed between task-related activities, such as WBB mediolateral weight shifting and the Step Test. The WBB, used with customised software, is a reliable and potentially useful tool for the assessment of balance and weight-bearing asymmetry following stroke. Future research is recommended to further investigate validity and responsiveness.

  19. System reliability worth assessment at a midwest utility-survey results for residential customers

    Energy Technology Data Exchange (ETDEWEB)

    Chowdhury, A.A.; Mielnik, T.C. [Electric System Planning, MidAmerican Energy Company, Davenport, Iowa (United States); Lawton, L.E.; Sullivan, M.J.; Katz, A. [Population Research Systems, San Francisco, CA (United States)

    2005-12-01

    This paper presents the overall results of a residential customer survey conducted in service areas of MidAmerican Energy Company, a Midwest utility. A similar survey was conducted concurrently in the industrial, commercial and institutional sectors and the survey results are presented in a companion paper. The results of this study are compared with the results of other studies performed in the high cost areas of the US east and west coasts. This is the first ever study of this nature performed for the residential customers in the US Midwest region. Methodological differences in the study design compared to coastal surveys are discussed. Customer survey costing techniques can be categorized into three main groups: contingent valuation techniques, direct costing techniques and indirect costing techniques. Most customer surveys conducted by different organizations in the last two decades used a combination of all three techniques. The selection of a technique is mainly dependent on the type of customer being surveyed. In this MidAmerican study, contingent valuation techniques and an indirect costing technique have been used, as most consequences of power outages to residential users are related to inconvenience or disruption of housekeeping and leisure activities that are intangible in nature. The major contribution of this paper is that particulars of Midwest residential customers compared to residential customers of coastal utilities are noted and customer responses on power quality issues that are important to customers are summarized. (author)

  20. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys

    NARCIS (Netherlands)

    van den Akker-Scheek, Inge; van Raay, Jos J. A. M.; Reininga, Inge H. F.; Bulstra, Sjoerd K.; Zijlstra, Wiebren; Stevens, Martin

    2010-01-01

    Background: Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement

  1. Instrumented static and dynamic balance assessment after stroke using Wii Balance Boards: reliability and association with clinical tests.

    Directory of Open Access Journals (Sweden)

    Kelly J Bower

    Full Text Available The Wii Balance Board (WBB is a globally accessible device that shows promise as a clinically useful balance assessment tool. Although the WBB has been found to be comparable to a laboratory-grade force platform for obtaining centre of pressure data, it has not been comprehensively studied in clinical populations. The aim of this study was to investigate the measurement properties of tests utilising the WBB in people after stroke.Thirty individuals who were more than three months post-stroke and able to stand unsupported were recruited from a single outpatient rehabilitation facility. Participants performed standardised assessments incorporating the WBB and customised software (static stance with eyes open and closed, static weight-bearing asymmetry, dynamic mediolateral weight shifting and dynamic sit-to-stand in addition to commonly employed clinical tests (10 Metre Walk Test, Timed Up and Go, Step Test and Functional Reach on two testing occasions one week apart. Test-retest reliability and construct validity of the WBB tests were investigated.All WBB-based outcomes were found to be highly reliable between testing occasions (ICC  = 0.82 to 0.98. Correlations were poor to moderate between WBB variables and clinical tests, with the strongest associations observed between task-related activities, such as WBB mediolateral weight shifting and the Step Test.The WBB, used with customised software, is a reliable and potentially useful tool for the assessment of balance and weight-bearing asymmetry following stroke. Future research is recommended to further investigate validity and responsiveness.

  2. Worldwide distribution of Total Reflection X-ray Fluorescence instrumentation and its different fields of application: A survey

    Energy Technology Data Exchange (ETDEWEB)

    Klockenkämper, Reinhold, E-mail: reinhold.klockenkaemper@isas.de; Bohlen, Alex von

    2014-09-01

    A survey was carried out with users and manufacturers of Total Reflection X-ray Fluorescence instrumentation in order to demonstrate the worldwide distribution of TXRF equipment and the different fields of applications. In general, TXRF users come from universities and scientific institutes, from working places at synchrotron beam-lines, or laboratories in semiconductor fabs. TXRF instrumentation is distributed in more than 50 countries on six continents and is applied at about 200 institutes and laboratories. The number of running desktop instruments amounts to nearly 300 units. About 60 beamlines run working places dedicated to TXRF. About 300 floor-mounted instruments are estimated to be used in about 150 fabs of the semiconductor industry. In total, 13 different fields of applications could be registered statistically from three different aspects. - Highlights: • According to the survey world maps show the distribution of TXRF equipment. • Nearly 700 individual units are running actually in 57 countries of 6 continents. • Users work at 200 universities, 60 synchrotron-beamlines, and 150 semiconductor fabs. • 13 fields of applications (e.g. environmental, chemical) are evaluated statistically. • Manufacturers, conference members and authors lead to 3 different pie-charts.

  3. Residential PV system users' perception of profitability, reliability, and failure risk: An empirical survey in a local Japanese municipality

    International Nuclear Information System (INIS)

    Mukai, Toshihiro; Kawamoto, Shishin; Ueda, Yuzuru; Saijo, Miki; Abe, Naoya

    2011-01-01

    Although previous studies have addressed the reliability of residential PV systems in order to improve the dissemination of the systems among individual users and societies, few have examined users' perception of their own PV systems, which might contain solutions to firmly establish the system into society. First, the present paper examined the extent to which residential PV system users understand specification, reliability, and failure risk of their own systems. Second, causal factors affecting users' satisfaction with PV systems were examined. By analyzing data collected in Kakegawa City, this paper revealed that users did not appropriately understand the basic specifications of their residential PV systems, and in particular, the fact that the systems sometimes failed and therefore needed proper maintenance. Furthermore, a strong causal relationship between users' expectations of financial return from the system and their level of satisfaction was confirmed empirically. These results suggested that excessive focus on profitability and relatively low interest in the systems' reliability and failure risk should be addressed more to avoid problems that could potentially hamper the establishment of this technology into society. - Highlights: → We examined PV users' perception of its specification, reliability, and failure risk. → Data for analysis were collected by questionnaire survey in a Japanese local municipality. → We revealed users did not appropriately understand the basic specifications. → A strong causal relationship between users' expectations of financial return and their level of satisfaction was confirmed empirically.

  4. Validation of a survey instrument to assess home environments for physical activity and healthy eating in overweight children

    Directory of Open Access Journals (Sweden)

    Crane Lori A

    2008-01-01

    Full Text Available Abstract Background Few measures exist to measure the overall home environment for its ability to support physical activity (PA and healthy eating in overweight children. The purpose of this study was to develop and test the reliability and validity of such a measure. Methods The Home Environment Survey (HES was developed to reflect availability, accessibility, parental role modelling, and parental policies related to PA resources, fruits and vegetables (F&V, and sugar sweetened drinks and snacks (SS. Parents of overweight children (n = 219 completed the HES and concurrent behavioural assessments. Children completed the Block Kids survey and wore an accelerometer for one week. A subset of parents (n = 156 completed the HES a second time to determine test-retest reliability. Finally, 41 parent dyads living in the same home (n = 41 completed the survey to determine inter-rater reliability. Initial psychometric analyses were completed to trim items from the measure based on lack of variability in responses, moderate or higher item to scale correlation, or contribution to strong internal consistency. Inter-rater and test-retest reliability were completed using intraclass correlation coefficients. Validity was assessed using Pearson correlations between the HES scores and child and parent nutrition and PA. Results Eight items were removed and acceptable internal consistency was documented for all scales (α = .66–84 with the exception of the F&V accessibility. The F&V accessibility was reduced to a single item because the other two items did not meet reliability standards. Test-retest reliability was high (r > .75 for all scales. Inter-rater reliability varied across scales (r = .22–.89. PA accessibility, parent role modelling, and parental policies were all related significantly to child (r = .14–.21 and parent (r = .15–.31 PA. Similarly, availability of F&V and SS, parental role modelling, and parental policies were related to child (r

  5. An approach based on defense-in-depth and diversity (3D) for the reliability assessment of digital instrument and control systems of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Paulo Adriano da; Saldanha, Pedro L.C., E-mail: pasilva@cnen.gov.b, E-mail: Saldanha@cnen.gov.b [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). Coord. Geral de Reatores Nucleares; Melo, Paulo F. Frutuoso e, E-mail: frutuoso@nuclear.ufrj.b [Universidade Federal do Rio de Janeiro (PEN/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao em Engenharia. Programa de Engenharia Nuclear; Araujo, Ademir L. de [Associacao Brasileira de Ensino Universitario (UNIABEU), Angra dos Reis, RJ (Brazil)

    2011-07-01

    The adoption of instrumentation and control (I and C) digital technology has been slower in nuclear power plants. The reason has been unfruitful efforts to obtain evidence in order to prove that I and C systems can be used in nuclear safety systems, for example, the Reactor Protection System (RPS), ensuring the proper operation of all its functions. This technology offers a potential improvement for safety and reliability. However, there still no consensus about the model to be adopted for digital systems software to be used in reliability studies. This paper presents the 3D methodology approach to assess digital I and C reliability. It is based on the study of operational events occurring in NPPs. It is easy to identify, in general, the level of I and C system reliability, showing its key vulnerabilities, enabling to trace regulatory actions to minimize or avoid them. This approach makes it possible to identify the main types of digital I and C system failure, with the potential for common cause failures as well as evaluating the dominant failure modes. The MAFIC-D software was developed to assist the implementation of the relationships between the reliability criteria, the analysis of relationships and data collection. The results obtained through this tool proved to be satisfactory and complete the process of regulatory decision-making from licensing I and C digital of NPPs and call still be used to monitor the performance of I and C digital post-licensing during the lifetime of the system, providing the basis for the elaboration of checklists of regulatory inspections. (author)

  6. An approach based on defense-in-depth and diversity (3D) for the reliability assessment of digital instrument and control systems of nuclear power plants

    International Nuclear Information System (INIS)

    Silva, Paulo Adriano da; Saldanha, Pedro L.C.

    2011-01-01

    The adoption of instrumentation and control (I and C) digital technology has been slower in nuclear power plants. The reason has been unfruitful efforts to obtain evidence in order to prove that I and C systems can be used in nuclear safety systems, for example, the Reactor Protection System (RPS), ensuring the proper operation of all its functions. This technology offers a potential improvement for safety and reliability. However, there still no consensus about the model to be adopted for digital systems software to be used in reliability studies. This paper presents the 3D methodology approach to assess digital I and C reliability. It is based on the study of operational events occurring in NPPs. It is easy to identify, in general, the level of I and C system reliability, showing its key vulnerabilities, enabling to trace regulatory actions to minimize or avoid them. This approach makes it possible to identify the main types of digital I and C system failure, with the potential for common cause failures as well as evaluating the dominant failure modes. The MAFIC-D software was developed to assist the implementation of the relationships between the reliability criteria, the analysis of relationships and data collection. The results obtained through this tool proved to be satisfactory and complete the process of regulatory decision-making from licensing I and C digital of NPPs and call still be used to monitor the performance of I and C digital post-licensing during the lifetime of the system, providing the basis for the elaboration of checklists of regulatory inspections. (author)

  7. A Survey on the Reliability of Power Electronics in Electro-Mobility Applications

    DEFF Research Database (Denmark)

    Gadalla, Brwene Salah Abdelkarim; Schaltz, Erik; Blaabjerg, Frede

    2015-01-01

    Reliability is an important issue in the field of power electronics since most of the electrical energy is today processed by power electronics. In most of the electro-mobility applications, e.g. electric and hybridelectric vehicles, power electronic are commonly used in very harsh environment...... and extending the service lifetime as well. Research within power electronics is of high interest as it has an important impact in the industry of the electro-mobility applications. According to the aforementioned explanations, this paper will provide an overview of the common factors (thermal cycles, power...... cycles, vibrations, voltage stress and current ripple stress) affecting the reliability of power electronics in electromobility applications. Also, the researchers perspective is summarized from 2001 to 2015....

  8. Corporate Entrepreneurship Assessment Instrument (CEAI): Refinement and Validation of a Survey Measure

    National Research Council Canada - National Science Library

    Cates, Michael S

    2007-01-01

    .... The measurement instrument known as the Corporate Entrepreneurship Assessment Index (CEAI) has been designed to tap the climate-related organizational factors that represent and potentially encourage corporate entrepreneurship...

  9. Validity and reliability testing of two instruments to measure breast cancer patients' concerns and information needs relating to radiation therapy

    Directory of Open Access Journals (Sweden)

    Kristjanson Linda J

    2007-11-01

    Full Text Available Abstract Background It is difficult to determine the most effective approach to patient education or tailor education interventions for patients in radiotherapy without tools that assess patients' specific radiation therapy information needs and concerns. Therefore, the aim of this study was to develop psychometrically sound tools to adequately determine the concerns and information needs of cancer patients during radiation therapy. Patients and Methods Two tools were developed to (1 determine patients concerns about radiation therapy (RT Concerns Scale and (2 ascertain patient's information needs at different time point during their radiation therapy (RT Information Needs Scale. Tools were based on previous research by the authors, published literature on breast cancer and radiation therapy and information behaviour research. Thirty-one breast cancer patients completed the questionnaire on one occasion and thirty participants completed the questionnaire on a second occasion to facilitate test-retest reliability. One participant's responses were removed from the analysis. Results were analysed for content validity, internal consistency and stability over time. Results Both tools demonstrated high internal consistency and adequate stability over time. The nine items in the RT Concerns Scale were retained because they met all pre-set psychometric criteria. Two items were deleted from the RT Information Needs Scale because they did not meet content validity criteria and did not achieve pre-specified criteria for internal consistency. This tool now contains 22 items. Conclusion This paper provides preliminary data suggesting that the two tools presented are reliable and valid and would be suitable for use in trials or in the clinical setting.

  10. Validity and reliability of instruments aimed at measuring Evidence-Based Practice in Physical Therapy: a systematic review of the literature.

    Science.gov (United States)

    Fernández-Domínguez, Juan Carlos; Sesé-Abad, Albert; Morales-Asencio, Jose Miguel; Oliva-Pascual-Vaca, Angel; Salinas-Bueno, Iosune; de Pedro-Gómez, Joan Ernest

    2014-12-01

    Our goal is to compile and analyse the characteristics - especially validity and reliability - of all the existing international tools that have been used to measure evidence-based clinical practice in physiotherapy. A systematic review conducted with data from exclusively quantitative-type studies synthesized in narrative format. An in-depth search of the literature was conducted in two phases: initial, structured, electronic search of databases and also journals with summarized evidence; followed by a residual-directed search in the bibliographical references of the main articles found in the primary search procedure. The studies included were assigned to members of the research team who acted as peer reviewers. Relevant information was extracted from each of the selected articles using a template that included the general characteristics of the instrument as well as an analysis of the quality of the validation processes carried out, by following the criteria of Terwee. Twenty-four instruments were found to comply with the review screening criteria; however, in all cases, they were found to be limited as regards the 'constructs' included. Besides, they can all be seen to be lacking as regards comprehensiveness associated to the validation process of the psychometric tests used. It seems that what constitutes a rigorously developed assessment instrument for EBP in physical therapy continues to be a challenge. © 2014 John Wiley & Sons, Ltd.

  11. Parents' self-efficacy, outcome expectations, and self-reported task performance when managing atopic dermatitis in children: instrument reliability and validity.

    Science.gov (United States)

    Mitchell, Amy E; Fraser, Jennifer A

    2011-02-01

    Support and education for parents faced with managing a child with atopic dermatitis is crucial to the success of current treatments. Interventions aiming to improve parent management of this condition are promising. Unfortunately, evaluation is hampered by lack of precise research tools to measure change. To develop a suite of valid and reliable research instruments to appraise parents' self-efficacy for performing atopic dermatitis management tasks; outcome expectations of performing management tasks; and self-reported task performance in a community sample of parents of children with atopic dermatitis. The Parents' Eczema Management Scale (PEMS) and the Parents' Outcome Expectations of Eczema Management Scale (POEEMS) were developed from an existing self-efficacy scale, the Parental Self-Efficacy with Eczema Care Index (PASECI). Each scale was presented in a single self-administered questionnaire, to measure self-efficacy, outcome expectations, and self-reported task performance related to managing child atopic dermatitis. Each was tested with a community sample of parents of children with atopic dermatitis, and psychometric evaluation of the scales' reliability and validity was conducted. A community-based convenience sample of 120 parents of children with atopic dermatitis completed the self-administered questionnaire. Participants were recruited through schools across Australia. Satisfactory internal consistency and test-retest reliability was demonstrated for all three scales. Construct validity was satisfactory, with positive relationships between self-efficacy for managing atopic dermatitis and general perceived self-efficacy; self-efficacy for managing atopic dermatitis and self-reported task performance; and self-efficacy for managing atopic dermatitis and outcome expectations. Factor analyses revealed two-factor structures for PEMS and PASECI alike, with both scales containing factors related to performing routine management tasks, and managing the

  12. Teaching Confirmatory Factor Analysis to Non-Statisticians: A Case Study for Estimating Composite Reliability of Psychometric Instruments

    Science.gov (United States)

    Gajewski, Byron J.; Jiang, Yu; Yeh, Hung-Wen; Engelman, Kimberly; Teel, Cynthia; Choi, Won S.; Greiner, K. Allen; Daley, Christine Makosky

    2013-01-01

    Texts and software that we are currently using for teaching multivariate analysis to non-statisticians lack in the delivery of confirmatory factor analysis (CFA). The purpose of this paper is to provide educators with a complement to these resources that includes CFA and its computation. We focus on how to use CFA to estimate a “composite reliability” of a psychometric instrument. This paper provides guidance for introducing, via a case-study, the non-statistician to CFA. As a complement to our instruction about the more traditional SPSS, we successfully piloted the software R for estimating CFA on nine non-statisticians. This approach can be used with healthcare graduate students taking a multivariate course, as well as modified for community stakeholders of our Center for American Indian Community Health (e.g. community advisory boards, summer interns, & research team members). The placement of CFA at the end of the class is strategic and gives us an opportunity to do some innovative teaching: (1) build ideas for understanding the case study using previous course work (such as ANOVA); (2) incorporate multi-dimensional scaling (that students already learned) into the selection of a factor structure (new concept); (3) use interactive data from the students (active learning); (4) review matrix algebra and its importance to psychometric evaluation; (5) show students how to do the calculation on their own; and (6) give students access to an actual recent research project. PMID:24772373

  13. Reliability of published data on radionuclide half lives - relevance to the use of reference sources for checking instrument performance

    International Nuclear Information System (INIS)

    Waldock, P.M.

    1999-01-01

    Long-lived calibrated radioisotopes are frequently used for checking of instrumentation used in the measurement of radiation; examples include: radioisotope assay meters, radiation monitors and sample counting equipment. In 1986 we purchased a radioisotope calibrator (Capintec CRC120) which was supplied with a number of long-lived check sources by the manufacturer, one of which was barium-133. The source came with its own calibration certificate and a quoted half life of 10.74 years ± 0.05 years, traceable to the National Bureau of Standards in the USA, and is consistent with data published by the National Nuclear Data Center, Brookhaven National Laboratory in 1985 (Tuli 1985). However, we noted at the time that this is significantly different to the value of 7.2 years quoted in the Radiochemical Manual (Wilson 1966) published by the Radiochemical Centre, Amersham (now Nycomed-Amersham), and more recently we have noted that it is significantly different to the value of 10.53 years currently quoted on various Internet sites including the University of Sheffield Chemistry Department (Winter 1999). Further investigation showed similar or worse variations of published half lives with time for several radioisotopes. Letter-to-the-editor

  14. Is the Scale for Measuring Motivational Interviewing Skills a valid and reliable instrument for measuring the primary care professionals motivational skills?: EVEM study protocol.

    Science.gov (United States)

    Pérula, Luis Á; Campiñez, Manuel; Bosch, Josep M; Barragán Brun, Nieves; Arboniés, Juan C; Bóveda Fontán, Julia; Martín Alvarez, Remedios; Prados, Jose A; Martín-Rioboó, Enrique; Massons, Josep; Criado, Margarita; Fernández, José Á; Parras, Juan M; Ruiz-Moral, Roger; Novo, Jesús M

    2012-11-22

    Lifestyle is one of the main determinants of people's health. It is essential to find the most effective prevention strategies to be used to encourage behavioral changes in their patients. Many theories are available that explain change or adherence to specific health behaviors in subjects. In this sense the named Motivational Interviewing has increasingly gained relevance. Few well-validated instruments are available for measuring doctors' communication skills, and more specifically the Motivational Interviewing. The hypothesis of this study is that the Scale for Measuring Motivational Interviewing Skills (EVEM questionnaire) is a valid and reliable instrument for measuring the primary care professionals skills to get behavior change in patients. To test the hypothesis we have designed a prospective, observational, multi-center study to validate a measuring instrument. - Thirty-two primary care centers in Spain. -Sampling and Size: a) face and consensual validity: A group composed of 15 experts in Motivational Interviewing. b) Assessment of the psychometric properties of the scale; 50 physician- patient encounters will be videoed; a total of 162 interviews will be conducted with six standardized patients, and another 200 interviews will be conducted with 50 real patients (n=362). Four physicians will be specially trained to assess 30 interviews randomly selected to test the scale reproducibility. -Measurements for to test the hypothesis: a) Face validity: development of a draft questionnaire based on a theoretical model, by using Delphi-type methodology with experts. b) Scale psychometric properties: intraobservers will evaluate video recorded interviews: content-scalability validity (Exploratory Factor Analysis), internal consistency (Cronbach alpha), intra-/inter-observer reliability (Kappa index, intraclass correlation coefficient, Bland & Altman methodology), generalizability, construct validity and sensitivity to change (Pearson product-moment correlation

  15. Is the Scale for Measuring Motivational Interviewing Skills a valid and reliable instrument for measuring the primary care professionals motivational skills?: EVEM study protocol

    Directory of Open Access Journals (Sweden)

    Pérula Luis Á

    2012-11-01

    Full Text Available Abstract Background Lifestyle is one of the main determinants of people’s health. It is essential to find the most effective prevention strategies to be used to encourage behavioral changes in their patients. Many theories are available that explain change or adherence to specific health behaviors in subjects. In this sense the named Motivational Interviewing has increasingly gained relevance. Few well-validated instruments are available for measuring doctors’ communication skills, and more specifically the Motivational Interviewing. Methods/Design The hypothesis of this study is that the Scale for Measuring Motivational Interviewing Skills (EVEM questionnaire is a valid and reliable instrument for measuring the primary care professionals skills to get behavior change in patients. To test the hypothesis we have designed a prospective, observational, multi-center study to validate a measuring instrument. –Scope: Thirty-two primary care centers in Spain. -Sampling and Size: a face and consensual validity: A group composed of 15 experts in Motivational Interviewing. b Assessment of the psychometric properties of the scale; 50 physician- patient encounters will be videoed; a total of 162 interviews will be conducted with six standardized patients, and another 200 interviews will be conducted with 50 real patients (n=362. Four physicians will be specially trained to assess 30 interviews randomly selected to test the scale reproducibility. -Measurements for to test the hypothesis: a Face validity: development of a draft questionnaire based on a theoretical model, by using Delphi-type methodology with experts. b Scale psychometric properties: intraobservers will evaluate video recorded interviews: content-scalability validity (Exploratory Factor Analysis, internal consistency (Cronbach alpha, intra-/inter-observer reliability (Kappa index, intraclass correlation coefficient, Bland & Altman methodology, generalizability, construct validity and

  16. Failure mode taxonomy for assessing the reliability of Field Programmable Gate Array based Instrumentation and Control systems

    International Nuclear Information System (INIS)

    McNelles, Phillip; Zeng, Zhao Chang; Renganathan, Guna; Chirila, Marius; Lu, Lixuan

    2017-01-01

    Highlights: • The use FPGAs in I&C systems in Nuclear Power Plants is an important issue (IAEA). • OECD-NEA published a failure mode taxonomy for software-based digital I&C systems. • This paper extends the OECD-NEA taxonomy to model FPGA-based systems. • FPGA failure modes, failure effects, uncovering methods are categorized/described. • Provides an example of modelling an FPGA-Based RTS/ESFAS using the FPGA taxonomy. - Abstract: Field Programmable Gate Arrays (FPGAs) are a form of programmable digital hardware configured to perform digital logic functions. This configuration (programming) is performed using Hardware Description Language (HDL), making FPGAs a form of HDL Programmed Device (HPD). In the nuclear field, FPGAs have seen use in upgrades and replacements of obsolete Instrumentation and Control (I&C) systems. This paper expands upon previous work that resulted in extensive FPGA failure mode data, to allow for the application of the OECD-NEA failure modes taxonomy. The OECD-NEA taxonomy presented a method to model digital (software-based) I&C systems, based on the hardware and software failure modes, failure uncovering effects and levels of abstraction, using a Reactor Trip System/Engineering Safety Feature Actuation System (RTS/ESFAS) as an example system. To create the FPGA taxonomy, this paper presents an additional “sub-component” level of abstraction, to demonstrate the effect of the FPGA failure modes and failure categories on an FPGA-based system. The proposed FPGA taxonomy is based on the FPGA failure modes, failure categories, failure effects and uncovering situations. The FPGA taxonomy is applied to the RTS/ESFAS test system, to demonstrate the effects of the anticipated FPGA failure modes on a digital I&C system, and to provide a modelling example for this proposed taxonomy.

  17. Safari Science: Assessing the reliability of citizen science data for wildlife surveys

    Science.gov (United States)

    Steger, Cara; Butt, Bilal; Hooten, Mevin B.

    2017-01-01

    Protected areas are the cornerstone of global conservation, yet financial support for basic monitoring infrastructure is lacking in 60% of them. Citizen science holds potential to address these shortcomings in wildlife monitoring, particularly for resource-limited conservation initiatives in developing countries – if we can account for the reliability of data produced by volunteer citizen scientists (VCS).This study tests the reliability of VCS data vs. data produced by trained ecologists, presenting a hierarchical framework for integrating diverse datasets to assess extra variability from VCS data.Our results show that while VCS data are likely to be overdispersed for our system, the overdispersion varies widely by species. We contend that citizen science methods, within the context of East African drylands, may be more appropriate for species with large body sizes, which are relatively rare, or those that form small herds. VCS perceptions of the charisma of a species may also influence their enthusiasm for recording it.Tailored programme design (such as incentives for VCS) may mitigate the biases in citizen science data and improve overall participation. However, the cost of designing and implementing high-quality citizen science programmes may be prohibitive for the small protected areas that would most benefit from these approaches.Synthesis and applications. As citizen science methods continue to gain momentum, it is critical that managers remain cautious in their implementation of these programmes while working to ensure methods match data purpose. Context-specific tests of citizen science data quality can improve programme implementation, and separate data models should be used when volunteer citizen scientists' variability differs from trained ecologists' data. Partnerships across protected areas and between protected areas and other conservation institutions could help to cover the costs of citizen science programme design and implementation.

  18. A survey of environmental exposure amongst locoshed workers by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Singh, V.K.N.; Garg, A.N.

    1995-01-01

    Instrumental neutron activation analysis (INAA) has been used for the determination of 16 elements in hair of locoshed workers (n=10) to study environmental exposure. A comparison of mean elemental contents with control (n=11) shows a significant enhancement for Cr, Th, Ca, Se and Na whereas Br and Sb show a declining trend. (author). 4 refs., 1 tab

  19. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. II. HIPPARCOS STARS OBSERVED IN 2010 JANUARY AND JUNE

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Gomez, Shamilia C.; Anderson, Lisa M.; Sherry, William H.; Howell, Steve B.; Ciardi, David R.; Van Altena, William F.

    2011-01-01

    The results of 497 speckle observations of Hipparcos stars and selected other targets are presented. Of these, 367 were resolved into components and 130 were unresolved. The data were obtained using the Differential Speckle Survey Instrument at the WIYN 3.5 m Telescope. (The WIYN Observatory is a joint facility of the University of Wisconsin-Madison, Indiana University, Yale University, and the National Optical Astronomy Observatories.) Since the first paper in this series, the instrument has been upgraded so that it now uses two electron-multiplying CCD cameras. The measurement precision obtained when comparing to ephemeris positions of binaries with very well known orbits is approximately 1-2 mas in separation and better than 0. 0 6 in position angle. Differential photometry is found to be in very good agreement with Hipparcos measures in cases where the comparison is most relevant. We derive preliminary orbits for two systems.

  20. Assessment of Perceived Stress Related to Migration and Acculturation in Patients with Psychiatric Disorders (MIGSTR10)-Development, Reliability, and Dimensionality of a Brief Instrument.

    Science.gov (United States)

    Müller, Matthias J; Zink, Sabrina; Koch, Eckhardt

    2017-09-01

    Assessment of stressors related to migration and acculturation in patients with psychiatric disorder and migration background could help improve culturally sensitive concepts of psychiatry and psychotherapy for diagnosis and treatment. The present overview delineates development and psychometric properties of an instrument (MIGSTR10) for assessment of stressors related to migration and acculturation, particularly for application in patients with psychiatric disorders. Ten migration-related stressors were derived from a qualitative content analysis of case histories of patients with psychiatric disorder and migration background and put into a suitable interview and questionnaire format (MIGSTR10; 10 questions, answer format: categorical yes/no, and dimensional 0-10) for self-assessment and observer ratings in several languages. Reliability (interrater agreement, internal consistency) and dimensionality (multi-dimensional scaling, MDS) were investigated in n = 235 patients with migration background and n = 612 indigenous German patients. Interrater agreement (ICC) for MIGSTR10 single items and sum scores (categorical and dimensional) was sufficiently high (≥.58); internal consistency (Cronbach's α) reached medium to high values (.56-.73). MDS revealed a two-dimensional solution with two item clusters (A: communication, migration history, forced marriage, homesickness, discrimination, other stressors; B: family conflicts, loss of status, feelings of shame, guilt feelings). The MIGSTR10 is a rationally developed, straightforward 10-item screening instrument with satisfactory psychometric properties for the assessment of individual and specific stressors related to migration and acculturation.

  1. Burnout Syndrome Among Medical Students at One University in Serbia: Validity and Reliability of the Maslach Burnout Inventory-Student Survey.

    Science.gov (United States)

    Ilic, Milena; Todorovic, Zeljko; Jovanovic, Milena; Ilic, Irena

    2017-01-01

    The Maslach Burnout Inventory-Student Survey (MBI-SS) contains 15 items that evaluate the following burnout dimensions: Emotional Exhaustion, Cynicism, and Academic Efficacy. The purpose of this study was to evaluate the dimensionality of the MBI-SS on a sample of Serbian medical students (N = 760). The overall Cronbach's α coefficient of the MBI-SS questionnaire was 0.757, while the Cronbach's α coefficients for Emotional Exhaustion, Cynicism, and Academic Efficacy were 0.869, 0.856, and 0.852, respectively. Principal Component Analysis with Oblimin rotation indicated 3 main components that explained 64.9% variance. The confirmatory factor analysis revealed good fit indices (χ 2 /df = 575.74/87, RMSEA = 0.086 (90% Confidence Interval for RMSEA = 0.079 to 0.092), CFI = 0.949, NNFI = 0.939, IFI = 0.949, GFI = 0.904) of the MBI-SS scale. The Serbian version of MBI-SS represents a valid and reliable instrument in the Serbian sample of medical students.

  2. Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, O., E-mail: osierra@sgc.gov.co; Parrado, G., E-mail: gparrado@sgc.gov.co; Cañón, Y.; Porras, A.; Alonso, D.; Herrera, D. C.; Peña, M., E-mail: mlpena@sgc.gov.co; Orozco, J. [Colombian Geological Survey, Nuclear Affairs Technical Division, Neutron Activation Analysis Laboratory, Bogota D. C. (Colombia)

    2016-07-07

    This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

  3. Improving the accuracy and reliability of MWD/magnetic-Wellbore-Directional surveying in the barents sea

    DEFF Research Database (Denmark)

    Edvardsen, I.; Nyrnes, E.; Johnsen, M. G.

    2014-01-01

    of nonmagnetic steel in the bottomhole assembly (BHA). To maintain azimuth uncertaintyat an acceptable level in northern areas, it is crucial that wellbore-directional-surveying requirements are given high priority and considered early during well planning. During the development phase of an oil and gas field...... magnetic-reference stations. The different land and sea configuration, distant offshore oil and gas fields, higher geomagnetic latitude, and different behavior of the magnetic field require the procedures to be reassessed before being applied to the Barents Sea. To reduce drilling delays, procedures must...... be implemented to enable efficient management of magnetic disturbances.In some areas of the Barents Sea, the management requires new equipment to be developed and tested before drilling, such as seabed magnetometer stations. One simple way to reduce drillstring interference is increasing the amount...

  4. The market for process control instrumentation in France. Foreign market survey report

    International Nuclear Information System (INIS)

    1977-04-01

    The market research was undertaken to study the present and potential US share of the market in France for process control instrumentation; to examine growth trends in French end-user industries over the next few years; to identify specific product categories that offer the most promising export potential for US companies; and to provide basic data which will assist US suppliers in determining current and potential sales and marketing opportunities. The trade promotional and marketing techniques were also reviewed

  5. Development of instrumentation for airborne radiometric surveys in the Atomic Minerals Division: Past, present, and future

    International Nuclear Information System (INIS)

    Sreehari, R.

    1993-01-01

    A high-sensitivity airborne gamma-ray spectrometric and magnetic survey system, using Na(Tl) detector volume of 50,000 cc for 4π and 4195 cc for 2π geometry applications, was designed, developed, and fabricated in 1978 and was flown for airborne surveys in various parts of India for over a decade. A compact complementary metal-oxide-semiconductor (CMOS) logic circuit based high-sensitivity airborne gamma-ray spectrometric and magnetic survey system with high noise-immunity using Na(Tl) detector volume of 50,000 cc for 4π and 12,500 cc for 2π geometry applications was developed and interfaced to an Inertial Navigation System in 1988. The system currently in use was flown extensively for airborne surveys in various parts of India for the Atomic Minerals Division, Oil and Natural Gas Commission, and Nuclear Power Corporation. The design aspects of the present system have been discussed. A microprocessor based DDAS and multichannel analysers, having on-line micro terminal and on-line corrections for Compton scatter, and background radiation to obtain corrected analog profiles for the spectrometric data, are currently under development. The design aspects of these units are described and evaluated for future high-sensitivity airborne gamma-ray spectrometric surveys with Nal(Tl) detector volumes similar to those of the present system. (author). 8 refs., 3 figs., 1 tab

  6. Organizational Member Involvement in Physical Activity Coalitions across the United States: Development and Testing of a Novel Survey Instrument for Assessing Coalition Functioning

    Science.gov (United States)

    Bornstein, Daniel B.; Pate, Russell R.; Beets, Michael W.; Saunders, Ruth P.; Blair, Steven N.

    2015-01-01

    Introduction: Coalitions are often composed of member organizations. Member involvement is thought to be associated with coalition success. No instrument currently exists for evaluating organizational member involvement in physical activity coalitions. This study aimed to develop a survey instrument for evaluating organizational member involvement…

  7. Methodological considerations concerning the development of oral dental erosion indexes: literature survey, validity and reliability

    Science.gov (United States)

    Kutschmann, Marcus; Bardehle, Doris

    2008-01-01

    Within the context of preventing non-communicable diseases, the World Health Report (2002) and the WHO Global Oral Health Program (2003) put forward a new strategy of disease prevention and health promotion. Greater emphasis is placed on developing global policies in oral health promotion and oral disease prevention. The Decayed, Missing, Filled Teeth (DMFT) index does not meet new challenges in the field of oral health. Dental erosion seems to be a growing problem, and in some countries, an increase in erosion of teeth is associated with an increase in the consumption of beverages containing acids. Therefore, within a revision of the WHO Oral Health Surveys Basic Methods, new oral disease patterns, e.g. dental erosion, have to be taken into account. Within the last 20 years, many studies on dental erosion have been carried out and published. There has been a rapid growth in the number of indexes quantifying dental erosion process in different age groups. However, these indexes are not comparable. This article discusses quality criteria which an index intended for assessing tooth erosion should possess. PMID:18228060

  8. A within-sample investigation of test–retest reliability in choice experiment surveys with real economic incentives

    DEFF Research Database (Denmark)

    Mørkbak, Morten Raun; Olsen, Søren Bøye

    2015-01-01

    In this paper, we investigate the level of agreement between respondents' choices in identical choice sets in a test-retest choice experiment for a market good with real economic incentives, thus investigating whether the incentivised CE method can be reliable and stable over time. Besides...... comparing choices, we also test for differences in preferences and error variance when a sample of respondents is given the exact same questionnaire twice, with a time lag of 2 weeks in between. Finally, we examine potential reasons and covariates explaining the level of agreement in choices across the 2...... weeks. Across four different tests, we find very good agreement between the two choice experiments - both with respect to overall choices and with respect to preferences. Furthermore, error variances do not differ significantly between the two surveys. The results also show that the larger the utility...

  9. Proposing a survey instrument for measuring operational, formal, information and strategic Internet skills

    NARCIS (Netherlands)

    van Deursen, Alexander Johannes Aloysius Maria; van Dijk, Johannes A.G.M.; Peters, O.

    2012-01-01

    Observational studies prove to be very suitable to provide a realistic view of people's Internet skills. However, their cost and time are a strong limitation for large-scale data gathering. A useful addition to the measurement of Internet skills would be the development of survey questions for

  10. Towards the development of an outcome instrument for spinal trauma : An international survey of spinal surgeons

    NARCIS (Netherlands)

    Oner, F. Cumhur; Sadiqi, Said; Lehr, A. Mechteld; Dvorak, Marcel F.; Aarabi, Bizhan; Chapman, Jens R.; Fehlings, Michael G.; Kandziora, Frank; Rajasekaran, S.; Vaccaro, Alexander R.

    2015-01-01

    STUDY DESIGN.: International web-based survey. OBJECTIVE.: To identify the most relevant aspects of human function and health status from the perspective of health care professionals involved in the treatment of spinal trauma patients. SUMMARY OF BACKGROUND DATA.: There is no universally accepted

  11. Safety instrumented systems in the oil and gas industry : Concepts and methods for safety and reliability assessments in design and operation

    Energy Technology Data Exchange (ETDEWEB)

    Lundteigen, Mary Ann

    2009-07-01

    This thesis proposes new methods and gives new insight to safety and reliability assessments of safety instrumented systems (SISs). These systems play an important role in many industry sectors and are used to detect the onset of hazardous events and mitigate their consequences to humans, the environment, and material assets. The thesis focuses on SIS applications in the oil and gas industry. Here, the SIS must respond to hazardous events such as gas leakages, fires, and over pressurization. Because there are personnel onboard the oil and gas installations, the operations take place in a vulnerable marine environment, and substantial values are associated with the offshore facilities, the reliability of SIS is of great concern to the public, the authorities, and the plant owners. The objective of this project has been to identify some of the key factors that influence the SIS reliability, clarify their effects on reliability, and suggest means to improve the treatment of these factors in safety and reliability assessments in design and operation. The project builds on concepts, methods, and definitions in two key standards for SIS design, construction, and operation: IEC 61508 and IEC 61511. The main contributions from this project are: A product development model that integrates reliability, availability, maintainability, and safety (RAMS) requirements with product development. The contributions have been presented in ten articles, five published in international journals, two submitted for publication, and three presented at conferences and in conference proceedings. The contributions are also directed to the industry and the actors that are involved in SIS design, construction, and operation. Even if the oil and gas industry is the main focus area, the results may be relevant for other industry sectors as well. SIS manufacturers and SIS designers face a large number of requirements from authorities, oil companies, international standards, and so on. At the same

  12. A Survey to Determine the Reliability of Dynamometer and Pinch Gauge Dial Readings Among Certified Hand Therapists

    Directory of Open Access Journals (Sweden)

    Theodore I. King II, Ph.D, L.Ac.

    2013-02-01

    Full Text Available Using a cross-sectional descriptive study design, surveys were mailed to 200 randomly selected certified hand therapists of the American Society of Hand Therapists (ASHT to determine how they document analog dynamometer and pinch gauge dial readings. Three different needle settings for the dynamometer and pinch gauge were presented in picture format. For each instrument, one needle setting was just above a gauge marker, one was just below a gauge marker, and one was set exactly between two gauge markers. A total of 126out of 200 surveys were returned for a participation rate of 63%. For the dynamometer readings, therapists estimated the exact strength reading between the two gauge markers 78.3% of the time. For the pinch gauge readings, therapists rounded to the nearest dial marker 76.5% of the time when the needle was just above or just below a dial marker and 61.9% of the time they estimated the reading when the needle was placed exactly between two dial markers.

  13. Progress in XRCS-Survey plant instrumentation and control design for ITER

    International Nuclear Information System (INIS)

    Varshney, Sanjeev; Jha, Shivakant; Simrock, Stefan; Barnsley, Robin; Martin, Vincent; Mishra, Sapna; Patil, Prabhakant; Patel, Shreyas; Kumar, Vinay

    2016-01-01

    Highlights: • An identification of the major process functions system compliant to Plant Control Design Handbook (PCDH) has been made for XRCS-Survey plant I&C. • I&C Functional Breakdown Structure (FBS) and Operation Procedure (OP) have been drafted using Enterprise architect (EA). • I&C architecture, interface with ITER networks and Plants, configuration of cubicles are discussed towards nine design review deliverables. - Abstract: A real time, plasma impurity survey system based on X-ray Crystal Spectroscopy (XRCS) has been designed for ITER and will be made available in the set of first plasma diagnostics for measuring impurity ion concentrations and their in-flux. For the purpose of developing a component level design of XRCS-Survey plant I&C system that is compliant to the rules and guidelines defined in the Plant Control Design Handbook (PCDH), firstly an identification of the major process functions has been made. The preliminary plant I&C Functional Breakdown Structure (FBS) and Operation Procedure (OP) have been drafted using a system engineering tool, Enterprise Architect (EA). Conceptual I&C architecture, interface with the ITER networks and other Plants have been discussed along with the basic configuration of I&C cubicles aiming towards nine I&C deliverables for the design review.

  14. Progress in XRCS-Survey plant instrumentation and control design for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Varshney, Sanjeev, E-mail: sanjeev.varshney@iter-india.org [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, 382 428 (India); Jha, Shivakant [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, 382 428 (India); Simrock, Stefan; Barnsley, Robin; Martin, Vincent [ITER-Organization, Route de Vinon sur Verdon, CS 90 046, 13067 St. Paul-Lez-Durance, Cedex (France); Mishra, Sapna [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, 382 428 (India); Patil, Prabhakant [ITER-Organization, Route de Vinon sur Verdon, CS 90 046, 13067 St. Paul-Lez-Durance, Cedex (France); Patel, Shreyas; Kumar, Vinay [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, 382 428 (India)

    2016-11-15

    Highlights: • An identification of the major process functions system compliant to Plant Control Design Handbook (PCDH) has been made for XRCS-Survey plant I&C. • I&C Functional Breakdown Structure (FBS) and Operation Procedure (OP) have been drafted using Enterprise architect (EA). • I&C architecture, interface with ITER networks and Plants, configuration of cubicles are discussed towards nine design review deliverables. - Abstract: A real time, plasma impurity survey system based on X-ray Crystal Spectroscopy (XRCS) has been designed for ITER and will be made available in the set of first plasma diagnostics for measuring impurity ion concentrations and their in-flux. For the purpose of developing a component level design of XRCS-Survey plant I&C system that is compliant to the rules and guidelines defined in the Plant Control Design Handbook (PCDH), firstly an identification of the major process functions has been made. The preliminary plant I&C Functional Breakdown Structure (FBS) and Operation Procedure (OP) have been drafted using a system engineering tool, Enterprise Architect (EA). Conceptual I&C architecture, interface with the ITER networks and other Plants have been discussed along with the basic configuration of I&C cubicles aiming towards nine I&C deliverables for the design review.

  15. Reliability and Validity of the Telephone-Based eHealth Literacy Scale Among Older Adults: Cross-Sectional Survey.

    Science.gov (United States)

    Stellefson, Michael; Paige, Samantha R; Tennant, Bethany; Alber, Julia M; Chaney, Beth H; Chaney, Don; Grossman, Suzanne

    2017-10-26

    Only a handful of studies have examined reliability and validity evidence of scores produced by the 8-item eHealth literacy Scale (eHEALS) among older adults. Older adults are generally more comfortable responding to survey items when asked by a real person rather than by completing self-administered paper-and-pencil or online questionnaires. However, no studies have explored the psychometrics of this scale when administered to older adults over the telephone. The objective of our study was to examine the reliability and internal structure of eHEALS data collected from older adults aged 50 years or older responding to items over the telephone. Respondents (N=283) completed eHEALS as part of a cross-sectional landline telephone survey. Exploratory structural equation modeling (E-SEM) analyses examined model fit of eHEALS scores with 1-, 2-, and 3-factor structures. Subsequent analyses based on the partial credit model explored the internal structure of eHEALS data. Compared with 1- and 2-factor models, the 3-factor eHEALS structure showed the best global E-SEM model fit indices (root mean square error of approximation=.07; comparative fit index=1.0; Tucker-Lewis index=1.0). Nonetheless, the 3 factors were highly correlated (r range .36 to .65). Item analyses revealed that eHEALS items 2 through 5 were overfit to a minor degree (mean square infit/outfit values information for respondents at similar points on the latent continuum. Test information curves suggested that eHEALS may capture more information about older adults at the higher end of the latent continuum (ie, those with high eHealth literacy) than at the lower end of the continuum (ie, those with low eHealth literacy). Item reliability (value=.92) and item separation (value=11.31) estimates indicated that eHEALS responses were reliable and stable. Results support administering eHEALS over the telephone when surveying older adults regarding their use of the Internet for health information. eHEALS scores best

  16. High School and Beyond. 1980 Senior Coort. Third-Follow-Up (1986). Data File User's Manual. Volume II: Survey Instruments. Contractor Report.

    Science.gov (United States)

    Sebring, Penny; And Others

    Survey instruments used in the collection of data for the High School and Beyond base year (1980) through the third follow-up surveys (1986) are provided as Volume II of a user's manual for the senior cohort data file. The complete user's manual is designed to provide the extensive documentation necessary for using the cohort data files. Copies of…

  17. Review report: safety and reliability issues on digital instrumentation and control systems in nuclear power plants and United States Nuclear Regulatory Commission`s dispositions

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Norio; Suzudo, Tomoaki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-09-01

    Recently, digital instrumentation and control (I and C) systems have been applied to nuclear power plants (NPPs) in various countries. Introduction of digital I and C systems, however, raises special issues on design, implementation, safety and licensing. Since FY 1997, the Japan Atomic Energy Research Institute (JAERI) has been carrying out a project, Study on Reliability of Digital I and C Systems, which includes extensive reviews of design approaches, technical standards, regulatory processes, especially, in the United States. This report summarizes the results from the study of National Research Council (NRC) and the U.S. Nuclear Regulatory Commission`s (USNRC`s) responses to the recommendations made by the NRC`s study. That study identified six technical key issues (system aspects of digital I and C technology, software quality assurance, common-mode software failure potential, safety and reliability assessment methods, human factors and man-machine interface, dedication of commercial off-the-shelf hardware and software) and two strategic key issues (case-by-case licensing process, adequacy of technical infrastructure) that arise from the introduction of digital I and C technology and then, made recommendations to the USNRC for coping with digital I and C applications. The USNRC responded to each recommendation and showed their own dispositions in which the USNRC agreed with most of the recommendations. In Japan, it is expected that introduction of digital I and C technology is inevitable in NPPs because the vendors are gradually discontinuing support and stocking of analog components. To cope with such situations, there is a need to develop and update the standards and guidelines applicable to digital I and C technology. The key issues and the USNRC`s dispositions provided in this report is believed to be useful for developing and updating them. (J.P.N.)

  18. Review report: safety and reliability issues on digital instrumentation and control systems in nuclear power plants and United States Nuclear Regulatory Commission's dispositions

    International Nuclear Information System (INIS)

    Watanabe, Norio; Suzudo, Tomoaki

    1998-09-01

    Recently, digital instrumentation and control (I and C) systems have been applied to nuclear power plants (NPPs) in various countries. Introduction of digital I and C systems, however, raises special issues on design, implementation, safety and licensing. Since FY 1997, the Japan Atomic Energy Research Institute (JAERI) has been carrying out a project, Study on Reliability of Digital I and C Systems, which includes extensive reviews of design approaches, technical standards, regulatory processes, especially, in the United States. This report summarizes the results from the study of National Research Council (NRC) and the U.S. Nuclear Regulatory Commission's (USNRC's) responses to the recommendations made by the NRC's study. That study identified six technical key issues (system aspects of digital I and C technology, software quality assurance, common-mode software failure potential, safety and reliability assessment methods, human factors and man-machine interface, dedication of commercial off-the-shelf hardware and software) and two strategic key issues (case-by-case licensing process, adequacy of technical infrastructure) that arise from the introduction of digital I and C technology and then, made recommendations to the USNRC for coping with digital I and C applications. The USNRC responded to each recommendation and showed their own dispositions in which the USNRC agreed with most of the recommendations. In Japan, it is expected that introduction of digital I and C technology is inevitable in NPPs because the vendors are gradually discontinuing support and stocking of analog components. To cope with such situations, there is a need to develop and update the standards and guidelines applicable to digital I and C technology. The key issues and the USNRC's dispositions provided in this report is believed to be useful for developing and updating them. (J.P.N.)

  19. Calibrate the aerial surveying instrument by the limited surface source and the single point source that replace the unlimited surface source

    CERN Document Server

    Lu Cun Heng

    1999-01-01

    It is described that the calculating formula and surveying result is found on the basis of the stacking principle of gamma ray and the feature of hexagonal surface source when the limited surface source replaces the unlimited surface source to calibrate the aerial survey instrument on the ground, and that it is found in the light of the exchanged principle of the gamma ray when the single point source replaces the unlimited surface source to calibrate aerial surveying instrument in the air. Meanwhile through the theoretical analysis, the receiving rate of the crystal bottom and side surfaces is calculated when aerial surveying instrument receives gamma ray. The mathematical expression of the gamma ray decaying following height according to the Jinge function regularity is got. According to this regularity, the absorbing coefficient that air absorbs the gamma ray and the detective efficiency coefficient of the crystal is calculated based on the ground and air measuring value of the bottom surface receiving cou...

  20. Instrument specifications and geophysical records for airborne electromagnetic survey of parts of Iron, Baraga, and Dickson Counties, Michigan

    Science.gov (United States)

    Heran, William D.; Smith, Bruce D.

    1980-01-01

    The data presented herein is from an airborne electromagnetic INPUT* survey conducted by Geoterrex Limited of Canada for the U.S. Geological Survey. The survey area is located in the central part of the Upper Peninsula of Michigan, within parts of Iron, Baraga, and Dickinson Counties. The general area covered is between 46°00' and 46°30' latitude and 88°00' and 88°30' longitude (fig. 1).The INPUT survey was flown as part of a U.S. Geological Survey CUSMAP (Conterminous United States Mineral Appraisal Program) project focusing on the Iron River 2° quadrangle. The survey was flown in order to provide geophysical information which will aid in an integrated geological assessment of mineral potentials of this part of the Iron River 2° quadrangle. The flight line spacing was chosen to maximize the areal coverage without a loss of resolution of major lithologic and structural features.East-west flight lines were flown 400 feet above ground at 1/2 mile intervals. Aerial photos were used for navigation, and the flight path was recorded on continuous-strip film. A continuously recording total field ground magnetic station was used to monitor variations in the Earth's magnetic field. One north-south line was flown to provide a tie for the magnetic data, which was recorded simultaneously with the electromagnetic data by a sensor mounted in the tail of the aircraft. This report is one of two open-file reports. The map in the other report Heran and Smith (1980) shows locations of the fiducial points, the flight lines, preliminary locations of anomalies and conductive zones; all plotted on an air photomosaic. The latitude and longitude ticks marked on this map are only approximate due to distortion in air photos used to recover the flight line position. This map is preliminary and is not to be considered a final interpretation. The present report contains a description of the instrument specifications, a copy of the ground station magnetic data, and a record of the

  1. Measuring genetic knowledge: a brief survey instrument for adolescents and adults.

    Science.gov (United States)

    Fitzgerald-Butt, S M; Bodine, A; Fry, K M; Ash, J; Zaidi, A N; Garg, V; Gerhardt, C A; McBride, K L

    2016-02-01

    Basic knowledge of genetics is essential for understanding genetic testing and counseling. The lack of a written, English language, validated, published measure has limited our ability to evaluate genetic knowledge of patients and families. Here, we begin the psychometric analysis of a true/false genetic knowledge measure. The 18-item measure was completed by parents of children with congenital heart defects (CHD) (n = 465) and adolescents and young adults with CHD (age: 15-25, n = 196) with a mean total correct score of 12.6 [standard deviation (SD) = 3.5, range: 0-18]. Utilizing exploratory factor analysis, we determined that one to three correlated factors, or abilities, were captured by our measure. Through confirmatory factor analysis, we determined that the two factor model was the best fit. Although it was necessary to remove two items, the remaining items exhibited adequate psychometric properties in a multidimensional item response theory analysis. Scores for each factor were computed, and a sum-score conversion table was derived. We conclude that this genetic knowledge measure discriminates best at low knowledge levels and is therefore well suited to determine a minimum adequate amount of genetic knowledge. However, further reliability testing and validation in diverse research and clinical settings is needed. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements†

    Science.gov (United States)

    Pröfrock, Daniel; Irrgeher, Johanna; Prohaska, Thomas

    2016-01-01

    The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC, measurement repeatability, within-lab reproducibility and deviation from certified values as well as a study on instrumental isotopic fractionation (IIF) and the calculation of the combined standard measurement uncertainty. Different approaches of correction for IIF applying external intra-elemental IIF correction (aka standard-sample bracketing) using certified S reference materials and internal inter-elemental IIF (aka internal standardization) correction using Si isotope ratios in MC ICP-MS are explained and compared. The resulting combined standard uncertainties of examined ICP-QMS systems were not better than 0.3–0.5% (uc,rel), which is in general insufficient to differentiate natural S isotope variations. Although the performance of the single collector ICP-SFMS is better (single measurement uc,rel = 0.08%), the measurement reproducibility (>0.2%) is the major limit of this system and leaves room for improvement. MC ICP-MS operated in the edge mass resolution mode, applying bracketing for correction of IIF, provided isotope ratio values with the highest quality (relative combined measurement uncertainty: 0.02%; deviation from the certified value: <0.002%). PMID:27812369

  3. Tomographic intensity mapping versus galaxy surveys: observing the Universe in H α emission with new generation instruments

    Science.gov (United States)

    Silva, B. Marta; Zaroubi, Saleem; Kooistra, Robin; Cooray, Asantha

    2018-04-01

    The H α line emission is an important probe for a number of fundamental quantities in galaxies, including their number density, star formation rate (SFR), and overall gas content. A new generation of low-resolution intensity mapping (IM) probes, e.g. SPHEREx and CDIM, will observe galaxies in H α emission over a large fraction of the sky from the local Universe till a redshift of z ˜ 6 - 10, respectively. This will also be the target line for observations by the high-resolution Euclid and WFIRST instruments in the z ˜ 0.7-2 redshift range. In this paper, we estimate the intensity and power spectra of the H α line in the z ˜ 0-5 redshift range using observed line luminosity functions (LFs), when possible, and simulations, otherwise. We estimate the significance of our predictions by accounting for the modelling uncertainties (e.g. SFR, extinction, etc.) and observational contamination. We find that IM surveys can make a statistical detection of the full H α emission between z ˜ 0.8 and 5. Moreover, we find that the high-frequency resolution and the sensitivity of the planned CDIM surveys allow for the separation of H α emission from several interloping lines. We explore ways to use the combination of these line intensities to probe galaxy properties. As expected, our study indicates that galaxy surveys will only detect bright galaxies that contribute up to a few per cent of the overall H α intensity. However, these surveys will provide important constraints on the high end of the H α LF and put strong constraints on the active galactic nucleus LF.

  4. Developing a theoretical model and questionnaire survey instrument to measure the success of electronic health records in residential aged care.

    Science.gov (United States)

    Yu, Ping; Qian, Siyu

    2018-01-01

    Electronic health records (EHR) are introduced into healthcare organizations worldwide to improve patient safety, healthcare quality and efficiency. A rigorous evaluation of this technology is important to reduce potential negative effects on patient and staff, to provide decision makers with accurate information for system improvement and to ensure return on investment. Therefore, this study develops a theoretical model and questionnaire survey instrument to assess the success of organizational EHR in routine use from the viewpoint of nursing staff in residential aged care homes. The proposed research model incorporates six variables in the reformulated DeLone and McLean information systems success model: system quality, information quality, service quality, use, user satisfaction and net benefits. Two variables training and self-efficacy were also incorporated into the model. A questionnaire survey instrument was designed to measure the eight variables in the model. After a pilot test, the measurement scale was used to collect data from 243 nursing staff members in 10 residential aged care homes belonging to three management groups in Australia. Partial least squares path modeling was conducted to validate the model. The validated EHR systems success model predicts the impact of the four antecedent variables-training, self-efficacy, system quality and information quality-on the net benefits, the indicator of EHR systems success, through the intermittent variables use and user satisfaction. A 24-item measurement scale was developed to quantitatively evaluate the performance of an EHR system. The parsimonious EHR systems success model and the measurement scale can be used to benchmark EHR systems success across organizations and units and over time.

  5. Academic Research Equipment in the Physical and Computer Sciences and Engineering. An Analysis of Findings from Phase I of the National Science Foundation's National Survey of Academic Research Instruments and Instrumentation Needs.

    Science.gov (United States)

    Burgdorf, Kenneth; White, Kristine

    This report presents information from phase I of a survey designed to develop quantitative indicators of the current national stock, cost/investment, condition, obsolescence, utilization, and need for major research instruments in academic settings. Data for phase I (which focused on the physical and computer sciences and engineering) were…

  6. Survey of point-of-care instrumentation, analysis, and quality assurance in veterinary practice.

    Science.gov (United States)

    Bell, Regan; Harr, Kendal; Rishniw, Mark; Pion, Paul

    2014-06-01

    While there have been ASVCP meeting discussions regarding quality assurance plans and lack thereof for in-clinic analyzers, there are little published data regarding in-clinic quality assurance and control practices. The purpose of this study was the identification of the common equipment used in hematologic, biochemical, urinalysis, and other testing, and assessment of quality control and assurance programs currently being performed in-clinic. All members of the Veterinary Information Network (VIN) were solicited to participate in an online survey between July and September 2007. In total, 452 complete or partial responses were received. Eighty-nine percent of respondents (361/404) said that veterinary technicians (unlicensed, licensed, and registered) performed the majority of analyses. Eighty-eight percent (366/417) of respondents performed some quality assurance on their laboratory equipment, most commonly on chemistry (91%, 324/357), and hematology (84%, 292/347) analyzers, and least commonly on fecal analyses (57%, 148/260) and ELISA assays (25%, 65/256). Ignorance of how to perform quality assurance was the most commonly stated reason (49%, 25/51) for lack of a quality assurance program. The majority of practices (316/374) utilized manufacturer-provided reference intervals without further adjustment or assessment. Roughly one-third of respondents (126/374) used reference intervals from textbooks, which is discouraged by ASVCP guidelines. This study found that the majority of respondents were not in compliance with ASVCP guidelines, illustrating the need for improved education of technical staff, veterinary students, and veterinarians regarding limitations of in-clinic laboratory equipment and the importance of regular quality control, maintenance, training, and reference interval development. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  7. Reliability and Validity of the Diabetes Eating Problem Survey in Turkish Children and Adolescents with Type 1 Diabetes Mellitus.

    Science.gov (United States)

    Atik Altınok, Yasemin; Özgür, Suriye; Meseri, Reci; Özen, Samim; Darcan, Şükran; Gökşen, Damla

    2017-12-15

    The aim of this study was to show the reliability and validity of a Turkish version of Diabetes Eating Problem Survey-Revised (DEPS-R) in children and adolescents with type 1 diabetes mellitus. A total of 200 children and adolescents with type 1 diabetes, ages 9-18 years, completed the DEPS-R Turkish version. In addition to tests of validity, confirmatory factor analysis was conducted to investigate the factor structure of the 16-item Turkish version of DEPS-R. The Turkish version of DEPS-R demonstrated satisfactory Cronbach's ∝ (0.847) and was significantly correlated with age (r=0.194; p1), hemoglobin A1c levels (r=0.303; p1), and body mass index-standard deviation score (r=0.412; p1) indicating criterion validity. Median DEPS-R scores of Turkish version for the total samples, females, and males were 11.0, 11.5, and 10.5, respectively. Disturbed eating behaviors and insulin restriction were associated with poor metabolic control. A short, self-administered diabetes-specific screening tool for disordered eating behavior can be used routinely in the clinical care of adolescents with type 1 diabetes. The Turkish version of DEPS-R is a valid screening tool for disordered eating behaviors in type 1 diabetes and it is potentially important to early detect disordered eating behaviors.

  8. Systems analysis programs for hands-on integrated reliability evaluations (SAPHIRE) Version 5.0. Fault tree, event tree, and piping ampersand instrumentation diagram (FEP) editors reference manual: Volume 7

    International Nuclear Information System (INIS)

    McKay, M.K.; Skinner, N.L.; Wood, S.T.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. The Fault Tree, Event Tree, and Piping and Instrumentation Diagram (FEP) editors allow the user to graphically build and edit fault trees, and event trees, and piping and instrumentation diagrams (P and IDs). The software is designed to enable the independent use of the graphical-based editors found in the Integrated Reliability and Risk Assessment System (IRRAS). FEP is comprised of three separate editors (Fault Tree, Event Tree, and Piping and Instrumentation Diagram) and a utility module. This reference manual provides a screen-by-screen guide of the entire FEP System

  9. The Mathematical Development Beliefs Survey: Validity and Reliability of a Measure of Preschool Teachers' Beliefs about the Learning and Teaching of Early Mathematics

    Science.gov (United States)

    Platas, Linda M.

    2015-01-01

    The Mathematical Development Beliefs Survey was developed to measure early childhood teachers' beliefs about mathematics teaching and learning in the preschool classroom. This instrument was designed to measure beliefs concerning (a) age-appropriateness of mathematics instruction, (b) classroom locus of generation of mathematical knowledge…

  10. A Reliability Generalization Study on the Survey of Perceived Organizational Support: The Effects of Mean Age and Number of Items on Score Reliability

    Science.gov (United States)

    Hellman, Chan M.; Fuqua, Dale R.; Worley, Jody

    2006-01-01

    The Survey of Perceived Organizational Support (SPOS) is a unidimensional measure of the general belief held by an employee that the organization is committed to him or her, values his or her continued membership, and is generally concerned about the employee's well-being. In the interest of efficiency, researchers are often compelled to use a…

  11. Developing a survey instrument to assess the readiness of primary care data, genetic and disease registries to conduct linked research: TRANSFoRm International Research Readiness (TIRRE survey instrument

    Directory of Open Access Journals (Sweden)

    Emily Leppenwell

    2013-05-01

    Full Text Available Background Clinical data are collected for routine care in family practice; there are also a growing number of genetic and cancer registry data repositories. The Translational Research and Patient Safety in Europe (TRANSFoRm project seeks to facilitate research using linked data from more than one source. We performed a requirements analysis which identified a wide range of data and business process requirements that need to be met before linking primary care and either genetic or disease registry data.Objectives To develop a survey to assess the readiness of data repositories to participate in linked research – the Transform International Research Readiness (TIRRE survey.Method We develop the questionnaire based on our requirement analysis; with questions at micro-, meso- and macro levels of granularity, study-specific questions about diabetes and gastro-oesophageal reflux disease (GORD, and research track record. The scope of the data required was extensive. We piloted this instrument, conducting ten preliminary telephone interviews to evaluate the response to the questionnaire.Results Using feedback gained from these interviews we revised the questionnaire; clarifying questions that were difficult to answer and utilising skip logic to create different series of questions for the various types of data repository. We simplified the questionnaire replacing free-text responses with yes/no or picking list options, wherever possible. We placed the final questionnaire online and encouraged its use (www.clininf.eu/jointirre/info.html.Conclusion Limited field testing suggests that TIRRE is capable of collecting comprehensive and relevant data about the suitability and readiness of data repositories to participate in linked data research.

  12. Failure Modes Taxonomy for Reliability Assessment of Digital Instrumentation and Control Systems for Probabilistic Risk Analysis - Failure modes taxonomy for reliability assessment of digital I and C systems for PRA

    International Nuclear Information System (INIS)

    Amri, A.; Blundell, N.; ); Authen, S.; Betancourt, L.; Coyne, K.; Halverson, D.; Li, M.; Taylor, G.; Bjoerkman, K.; Brinkman, H.; Postma, W.; Bruneliere, H.; Chirila, M.; Gheorge, R.; Chu, L.; Yue, M.; Delache, J.; Georgescu, G.; Deleuze, G.; Quatrain, R.; Thuy, N.; Holmberg, J.-E.; Kim, M.C.; Kondo, K.; Mancini, F.; Piljugin, E.; Stiller, J.; Sedlak, J.; Smidts, C.; Sopira, V.

    2015-01-01

    Digital protection and control systems appear as upgrades in older nuclear power plants (NPP), and are commonplace in new NPPs. To assess the risk of NPP operation and to determine the risk impact of digital systems, there is a need to quantitatively assess the reliability of the digital systems in a justifiable manner. Due to the many unique attributes of digital systems (e.g., functions are implemented by software, units of the system interact in a communication network, faults can be identified and handled online), a number of modelling and data collection challenges exist, and international consensus on the reliability modelling has not yet been reached. The objective of the task group called DIGREL has been to develop a taxonomy of failure modes of digital components for the purposes of probabilistic risk analysis (PRA). An activity focused on the development of a common taxonomy of failure modes is seen as an important step towards standardised digital instrumentation and control (I and C) reliability assessment techniques for PRA. Needs from PRA has guided the work, meaning, e.g., that the I and C system and its failures are studied from the point of view of their functional significance point of view. The taxonomy will be the basis of future modelling and quantification efforts. It will also help to define a structure for data collection and to review PRA studies. The proposed failure modes taxonomy has been developed by first collecting examples of taxonomies provided by the task group organisations. This material showed some variety in the handling of I and C hardware failure modes, depending on the context where the failure modes have been defined. Regarding the software part of I and C, failure modes defined in NPP PRAs have been simple - typically a software CCF failing identical processing units. The DIGREL task group has defined a new failure modes taxonomy based on a hierarchical definition of five levels of abstraction: 1. system level (complete

  13. A Frailty Instrument for primary care: findings from the Survey of Health, Ageing and Retirement in Europe (SHARE

    Directory of Open Access Journals (Sweden)

    Romero-Ortuno Roman

    2010-08-01

    Full Text Available Abstract Background A frailty paradigm would be useful in primary care to identify older people at risk, but appropriate metrics at that level are lacking. We created and validated a simple instrument for frailty screening in Europeans aged ≥50. Our study is based on the first wave of the Survey of Health, Ageing and Retirement in Europe (SHARE, http://www.share-project.org, a large population-based survey conducted in 2004-2005 in twelve European countries. Methods Subjects: SHARE Wave 1 respondents (17,304 females and 13,811 males. Measures: five SHARE variables approximating Fried's frailty definition. Analyses (for each gender: 1 estimation of a discreet factor (DFactor model based on the frailty variables using LatentGOLD®. A single DFactor with three ordered levels or latent classes (i.e. non-frail, pre-frail and frail was modelled; 2 the latent classes were characterised against a biopsychosocial range of Wave 1 variables; 3 the prospective mortality risk (unadjusted and age-adjusted for each frailty class was established on those subjects with known mortality status at Wave 2 (2007-2008 (11,384 females and 9,163 males; 4 two web-based calculators were created for easy retrieval of a subject's frailty class given any five measurements. Results Females: the DFactor model included 15,578 cases (standard R2 = 0.61. All five frailty indicators discriminated well (p N = 10,420; 66.9%, pre-frail (N = 4,025; 25.8%, and frail (N = 1,133; 7.3%. Relative to the non-frail class, the age-adjusted Odds Ratio (with 95% Confidence Interval for mortality at Wave 2 was 2.1 (1.4 - 3.0 in the pre-frail and 4.8 (3.1 - 7.4 in the frail. Males: 12,783 cases (standard R2 = 0.61, all frailty indicators had p N = 10,517; 82.3%, pre-frail (N = 1,871; 14.6%, and frail (N = 395; 3.1%; age-adjusted OR (95% CI for mortality: 3.0 (2.3 - 4.0 in the pre-frail, 6.9 (4.7 - 10.2 in the frail. Conclusions The SHARE Frailty Instrument has sufficient construct and

  14. Techniques, processes, and measures for software safety and reliability

    International Nuclear Information System (INIS)

    Sparkman, D.

    1992-01-01

    The purpose of this report is to provide a detailed survey of current recommended practices and measurement techniques for the development of reliable and safe software-based systems. This report is intended to assist the United States Nuclear Reaction Regulation (NRR) in determining the importance and maturity of the available techniques and in assessing the relevance of individual standards for application to instrumentation and control systems in nuclear power generating stations. Lawrence Livermore National Laboratory (LLNL) provides technical support for the Instrumentation and Control System Branch (ICSB) of NRRin advanced instrumentation and control systems, distributed digital systems, software reliability, and the application of verificafion and validafion for the development of software

  15. Using computer-assisted survey instruments instead of paper and pencil increased completeness of self-administered sexual behavior questionnaires.

    Science.gov (United States)

    Spark, Simone; Lewis, Dyani; Vaisey, Alaina; Smyth, Eris; Wood, Anna; Temple-Smith, Meredith; Lorch, Rebecca; Guy, Rebecca; Hocking, Jane

    2015-01-01

    To compare the data quality, logistics, and cost of a self-administered sexual behavior questionnaire administered either using a computer-assisted survey instrument (CASI) or by paper and pencil in a primary care clinic. A self-administered sexual behavior questionnaire was administered to 16-29 year olds attending general practice. Questionnaires were administered by either paper and pencil (paper) or CASI. A personal digital assistant was used to self-administer the CASI. A total of 4,491 people completed the questionnaire, with 46.9% responses via CASI and 53.2% by paper. Completion of questions was greater for CASI than for paper for sexual behavior questions: number of sexual partners [odds ratio (OR), 6.85; 95% confidence interval (CI): 3.32, 14.11] and ever having had sex with a person of the same gender (OR, 2.89; 95% CI: 1.52, 5.49). The median number of questions answered was higher for CASI than for paper (17.6 vs. 17.2; P questionnaire compared with $11.83 for paper. Electronic devices using CASI are a tool that can increase participants' questionnaire responses and deliver more complete data for a sexual behavior questionnaire in primary care clinics. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Reliability and validity of 12-item Short-Form health survey (SF-12) for the health status of Chinese community elderly population in Xujiahui district of Shanghai.

    Science.gov (United States)

    Shou, Juan; Ren, Limin; Wang, Haitang; Yan, Fei; Cao, Xiaoyun; Wang, Hui; Wang, Zhiliang; Zhu, Shanzhu; Liu, Yao

    2016-04-01

    The 12-item Short-Form Health Survey (SF-12) is the abridged practical version of SF-36. This cross-sectional study was aimed to assess the reliability and validity of SF-12 for the health status of Chinese community elderly population. The Chinese community elderly people in Xujiahui district of Shanghai were investigated. The internal consistency reliability was assessed using Cronbach's alpha and split-half reliability coefficients. Construct validity was analyzed using exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). Spearman's correlation coefficient (ρ) was used for the evaluation of criterion, convergent, and discriminant validity with Spearman's ρ ≥ 0.4 as satisfactory. Comparisons of the SF-12 summary scores among populations that differed in demographics were performed for discriminant validity. Total 1343 individuals aged ≥60 and reliability coefficient (0.812) reflected satisfactory internal consistency reliability of SF-12. EFA extracted a two-factor model (physical and mental health). About 60.7 % of the total variance was explained by the two factors. CFA showed that the two-factor solution provided a good fit to the data. Good convergent validity and discriminant validity of SF-12 were proved by the correction analyses (Spearman's ρ > 0.4) and the comparisons of the SF-12 summary scores among populations (P  0.4, P reliability and validity in measuring health status of Chinese community elderly population in Xujiahui district of Shanghai.

  17. New York City School Survey 2008-2010: Assessing the Reliability and Validity of a Progress Report Measure. Technical Report

    Science.gov (United States)

    Nathanson, Lori; Cole, Rachel; Kemple, James J.; Lent, Jessica; McCormick, Meghan; Segeritz, Micha

    2013-01-01

    The Research Alliance for New York City Schools examined Department of Education (DOE) School Survey data from 2008-2010 to better understand the richness and complexities of the information elicited by the Survey from parents, students, and teachers. This report provides background information on the development of the NYC School Surveys during…

  18. Reliability and prevalence of physical performance examination assessing mobility and balance in older persons in the US: data from the Third National Health and Nutrition Examination Survey.

    Science.gov (United States)

    Ostchega, Y; Harris, T B; Hirsch, R; Parsons, V L; Kington, R; Katzoff, M

    2000-09-01

    This report provides reliability and prevalence estimates by sex, age, and race/ethnicity of an observed physical performance examination (PPE) assessing mobility and balance. The Third National Health and Nutrition Examination Survey (NHANES III) 1988-1994. A cross-sectional nationally representative survey. All persons aged 60 and older (n = 5,403) who performed the PPE either in the mobile examination center (MEC) or in the home during NHANES III (conducted 1988-1994). The PPE included timed chair stand, full tandem stand, and timed 8-foot walk. Timed chair stand and 8-foot timed walk were reliable measurements (Intraclass Correlations > 0.5). Women were significantly slower (P physically limited than men.

  19. Reliability engineering

    International Nuclear Information System (INIS)

    Lee, Chi Woo; Kim, Sun Jin; Lee, Seung Woo; Jeong, Sang Yeong

    1993-08-01

    This book start what is reliability? such as origin of reliability problems, definition of reliability and reliability and use of reliability. It also deals with probability and calculation of reliability, reliability function and failure rate, probability distribution of reliability, assumption of MTBF, process of probability distribution, down time, maintainability and availability, break down maintenance and preventive maintenance design of reliability, design of reliability for prediction and statistics, reliability test, reliability data and design and management of reliability.

  20. ASRDI oxygen technology survey. Volume 5: Density and liquid level measurement instrumentation for the cryogenic fluids oxygen, hydrogen, and nitrogen

    Science.gov (United States)

    Roder, H. M.

    1974-01-01

    Information is presented on instrumentation for density measurement, liquid level measurement, quantity gauging, and phase measurement. Coverage of existing information directly concerned with oxygen was given primary emphasis. A description of the physical principle of measurement for each instrumentation type is included. The basic materials of construction are listed if available from the source document for each instrument discussed. Cleaning requirements, procedures, and verification techniques are included.

  1. Reliability and validity of the Children's Fear Survey Schedule-Dental Subscale for Arabic-speaking children: a cross-sectional study.

    Science.gov (United States)

    El-Housseiny, Azza A; Alsadat, Farah A; Alamoudi, Najlaa M; El Derwi, Douaa A; Farsi, Najat M; Attar, Moaz H; Andijani, Basil M

    2016-04-14

    Early recognition of dental fear is essential for the effective delivery of dental care. This study aimed to test the reliability and validity of the Arabic version of the Children's Fear Survey Schedule-Dental Subscale (CFSS-DS). A school-based sample of 1546 children was randomly recruited. The Arabic version of the CFSS-DS was completed by children during class time. The scale was tested for internal consistency and test-retest reliability. To test criterion validity, children's behavior was assessed using the Frankl scale during dental examination, and results were compared with children's CFSS-DS scores. To test the scale's construct validity, scores on "fear of going to the dentist soon" were correlated with CFSS-DS scores. Factor analysis was also used. The Arabic version of the CFSS-DS showed high reliability regarding both test-retest reliability (intraclass correlation = 0.83, p children with negative behavior had significantly higher fear scores (t = 13.67, p fear of invasive dental procedures," "fear of less invasive dental procedures" and "fear of strangers." The Arabic version of the CFSS-DS is a reliable and valid measure of dental fear in Arabic-speaking children. Pediatric dentists and researchers may use this validated version of the CFSS-DS to measure dental fear in Arabic-speaking children.

  2. Calibrate the aerial surveying instrument by the limited surface source and the single point source that replace the unlimited surface source

    International Nuclear Information System (INIS)

    Lu Cunheng

    1999-01-01

    It is described that the calculating formula and surveying result is found on the basis of the stacking principle of gamma ray and the feature of hexagonal surface source when the limited surface source replaces the unlimited surface source to calibrate the aerial survey instrument on the ground, and that it is found in the light of the exchanged principle of the gamma ray when the single point source replaces the unlimited surface source to calibrate aerial surveying instrument in the air. Meanwhile through the theoretical analysis, the receiving rate of the crystal bottom and side surfaces is calculated when aerial surveying instrument receives gamma ray. The mathematical expression of the gamma ray decaying following height according to the Jinge function regularity is got. According to this regularity, the absorbing coefficient that air absorbs the gamma ray and the detective efficiency coefficient of the crystal is calculated based on the ground and air measuring value of the bottom surface receiving count rate (derived from total receiving count rate of the bottom and side surface). Finally, according to the measuring value, it is proved that imitating the change of total receiving gamma ray exposure rate of the bottom and side surfaces with this regularity in a certain high area is feasible

  3. New York City School Survey 2008-2010: Assessing the Reliability and Validity of a Progress Report Measure. Technical Appendices

    Science.gov (United States)

    Nathanson, Lori; Cole, Rachel; Kemple, James J.; Lent, Jessica; McCormick, Meghan; Segeritz, Micha

    2013-01-01

    The Research Alliance for New York City Schools examined Department of Education (DOE) School Survey data from 2008-2010 to better understand the richness and complexities of the information elicited by the Survey from parents, students, and teachers. This document provides the appendices to the technical report "New York City School Survey…

  4. RELIABLE IDENTIFICATIONS OF ACTIVE GALACTIC NUCLEI FROM THE WISE, 2MASS, AND ROSAT ALL-SKY SURVEYS

    International Nuclear Information System (INIS)

    Edelson, R.; Malkan, M.

    2012-01-01

    We have developed the ''S IX '' statistic to identify bright, highly likely active galactic nucleus (AGN) candidates solely on the basis of Wide-field Infrared Survey Explorer (WISE), Two Micron All-Sky Survey (2MASS), and ROSAT all-sky survey (RASS) data. This statistic was optimized with data from the preliminary WISE survey and the Sloan Digital Sky Survey, and tested with Lick 3 m Kast spectroscopy. We find that sources with S IX 95% likelihood of being an AGN (defined in this paper as a Seyfert 1, quasar, or blazar). This statistic was then applied to the full WISE/2MASS/RASS dataset, including the final WISE data release, to yield the ''W2R'' sample of 4316 sources with S IX 2 , permitting construction of AGN samples in any sufficiently large region of sky.

  5. Test-retest reliability of selected items of Health Behaviour in School-aged Children (HBSC survey questionnaire in Beijing, China

    Directory of Open Access Journals (Sweden)

    Liu Yang

    2010-08-01

    Full Text Available Abstract Background Children's health and health behaviour are essential for their development and it is important to obtain abundant and accurate information to understand young people's health and health behaviour. The Health Behaviour in School-aged Children (HBSC study is among the first large-scale international surveys on adolescent health through self-report questionnaires. So far, more than 40 countries in Europe and North America have been involved in the HBSC study. The purpose of this study is to assess the test-retest reliability of selected items in the Chinese version of the HBSC survey questionnaire in a sample of adolescents in Beijing, China. Methods A sample of 95 male and female students aged 11 or 15 years old participated in a test and retest with a three weeks interval. Student Identity numbers of respondents were utilized to permit matching of test-retest questionnaires. 23 items concerning physical activity, sedentary behaviour, sleep and substance use were evaluated by using the percentage of response shifts and the single measure Intraclass Correlation Coefficients (ICC with 95% confidence interval (CI for all respondents and stratified by gender and age. Items on substance use were only evaluated for school children aged 15 years old. Results The percentage of no response shift between test and retest varied from 32% for the item on computer use at weekends to 92% for the three items on smoking. Of all the 23 items evaluated, 6 items (26% showed a moderate reliability, 12 items (52% displayed a substantial reliability and 4 items (17% indicated almost perfect reliability. No gender and age group difference of the test-retest reliability was found except for a few items on sedentary behaviour. Conclusions The overall findings of this study suggest that most selected indicators in the HBSC survey questionnaire have satisfactory test-retest reliability for the students in Beijing. Further test-retest studies in a large

  6. Are population health surveys reliable for self-reporting conditions and relative well-being for those with asthma?

    Directory of Open Access Journals (Sweden)

    Tony Whiffen

    2018-06-01

    Linkage of survey data can provide useful insights into relative levels of self-reported illnesses and subjective well-being but can also be used effectively to explore the risks that other morbidities present to mental wellbeing.

  7. Identifying depression post-stroke in patients with aphasia : A systematic review of the reliability, validity and feasibility of available instruments

    NARCIS (Netherlands)

    van Dijk, Mariska J; de Man-van Ginkel, Janneke M; Hafsteinsdóttir, Thóra B; Schuurmans, Marieke J

    OBJECTIVE: To identify and critically appraise the evidence for instruments assessing depression in stroke patients with aphasia. METHODS: The PubMed, CINAHL, Web of Science, Psych Info and Cochrane databases were searched from inception until May 2015. RESULTS: Of the 383 titles found in the

  8. Being an Informed Consumer of Health Information and Assessment of Electronic Health Literacy in a National Sample of Internet Users: Validity and Reliability of the e-HLS Instrument.

    Science.gov (United States)

    Seçkin, Gül; Yeatts, Dale; Hughes, Susan; Hudson, Cassie; Bell, Valarie

    2016-07-11

    The Internet, with its capacity to provide information that transcends time and space barriers, continues to transform how people find and apply information to their own lives. With the current explosion in electronic sources of health information, including thousands of websites and hundreds of mobile phone health apps, electronic health literacy is gaining an increasing prominence in health and medical research. An important dimension of electronic health literacy is the ability to appraise the quality of information that will facilitate everyday health care decisions. Health information seekers explore their care options by gathering information from health websites, blogs, Web-based forums, social networking websites, and advertisements, despite the fact that information quality on the Internet varies greatly. Nonetheless, research has lagged behind in establishing multidimensional instruments, in part due to the evolving construct of health literacy itself. The purpose of this study was to examine psychometric properties of a new electronic health literacy (ehealth literacy) measure in a national sample of Internet users with specific attention to older users. Our paper is motivated by the fact that ehealth literacy is an underinvestigated area of inquiry. Our sample was drawn from a panel of more than 55,000 participants maintained by Knowledge Networks, the largest national probability-based research panel for Web-based surveys. We examined the factor structure of a 19-item electronic Health Literacy Scale (e-HLS) through exploratory factor analysis (EFA) and confirmatory factor analysis, internal consistency reliability, and construct validity on sample of adults (n=710) and a subsample of older adults (n=194). The AMOS graphics program 21.0 was used to construct a measurement model, linking latent factors obtained from EFA with 19 indicators to determine whether this factor structure achieved a good fit with our entire sample and the subsample (age ≥ 60

  9. Manual dexterity in hereditary motor and sensory neuropathy type 1a: severity of limitations and feasibility and reliability of two assessment instruments

    NARCIS (Netherlands)

    Videler, Annemieke J.; Beelen, Anita; van Schaik, Ivo N.; de Visser, Marianne; Nollet, Frans

    2008-01-01

    OBJECTIVE: To assess the prevalence and significance of impaired manual dexterity in hereditary motor and sensory neuropathy type 1a (HMSN 1a), with the Sollerman hand function and the Functional Dexterity test, and compare the reliability and agreement of the tests. DESIGN: Descriptive

  10. Survey and analysis of radiation safety management systems at medical institutions. Second report. Radiation measurement, calibration of radiation survey meters, and periodic check of installations, equipment, and protection instruments

    International Nuclear Information System (INIS)

    Ohba, Hisateru; Ogasawara, Katsuhiko; Aburano, Tamio

    2006-01-01

    We carried out a questionnaire survey to determine the actual situation of radiation safety management measures in all medical institutions in Japan that had nuclear medicine facilities. The questionnaire consisted of questions concerning the evaluation of shielding capacity; radiation measurement; periodic checks of installations, equipment, and protection instruments; and the calibration of radiation survey meters. The analysis was undertaken according to region, type of establishment, and number of beds. The overall response rate was 60 percent. For the evaluation of shielding capacity, the outsourcing rate was 53 percent of the total. For the radiation measurements of ''leakage radiation dose and radioactive contamination'' and contamination of radioactive substances in the air'', the outsourcing rates were 28 percent and 35 percent of the total, respectively (p<0.001, according to region and establishment). For the periodic check of radiation protection instruments, the implementation rate was 98 percent, and the outsourcing rate was 32 percent for radiation survey meters and 47 percent for lead aprons. The non-implemented rate for calibration of radiation survey meters was 25 percent of the total (p<0.001, according to region and establishment). The outsourcing rate for calibration of radiation survey meters accounted for 87 percent of the total, and of these medical institutions, 72 percent undertook annual calibration. The implementation rate for patient exposure measurement was 20 percent of the total (p<0.001, according to number of beds), and of these medical institutions 46 percent recorded measurement outcome. (author)

  11. RELIABLE IDENTIFICATIONS OF ACTIVE GALACTIC NUCLEI FROM THE WISE, 2MASS, AND ROSAT ALL-SKY SURVEYS

    Energy Technology Data Exchange (ETDEWEB)

    Edelson, R. [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Malkan, M., E-mail: rickedelson@gmail.com [Department of Physics and Astronomy, University of California Los Angeles, Los Angeles, CA 90095-1547 (United States)

    2012-05-20

    We have developed the ''S{sub IX}'' statistic to identify bright, highly likely active galactic nucleus (AGN) candidates solely on the basis of Wide-field Infrared Survey Explorer (WISE), Two Micron All-Sky Survey (2MASS), and ROSAT all-sky survey (RASS) data. This statistic was optimized with data from the preliminary WISE survey and the Sloan Digital Sky Survey, and tested with Lick 3 m Kast spectroscopy. We find that sources with S{sub IX} < 0 have a {approx}>95% likelihood of being an AGN (defined in this paper as a Seyfert 1, quasar, or blazar). This statistic was then applied to the full WISE/2MASS/RASS dataset, including the final WISE data release, to yield the ''W2R'' sample of 4316 sources with S{sub IX} < 0. Only 2209 of these sources are currently in the Veron-Cetty and Veron (VCV) catalog of spectroscopically confirmed AGNs, indicating that the W2R sample contains nearly 2000 new, relatively bright (J {approx}< 16) AGNs. We utilize the W2R sample to quantify biases and incompleteness in the VCV catalog. We find that it is highly complete for bright (J < 14), northern AGNs, but the completeness drops below 50% for fainter, southern samples and for sources near the Galactic plane. This approach also led to the spectroscopic identification of 10 new AGNs in the Kepler field, more than doubling the number of AGNs being monitored by Kepler. The W2R sample contains better than 1 bright AGN every 10 deg{sup 2}, permitting construction of AGN samples in any sufficiently large region of sky.

  12. Evaluation of the two non-consecutive 24-h recall instrument for pan-European food consumption surveys

    NARCIS (Netherlands)

    Crispim, S.P.

    2011-01-01

    Background: The comparability of food consumption data originating from national nutritional surveys in Europe is currently hampered because of different methodologies used. Therefore, experts in the European Food Consumption Survey Method (EFCOSUM) consortium proposed to use two non-consecutive

  13. Reliability and Validity of a Survey of Cat Caregivers on Their Cats’ Socialization Level in the Cat’s Normal Environment

    Directory of Open Access Journals (Sweden)

    Margaret Slater

    2013-12-01

    Full Text Available Stray cats routinely enter animal welfare organizations each year and shelters are challenged with determining the level of human socialization these cats may possess as quickly as possible. However, there is currently no standard process to guide this determination. This study describes the development and validation of a caregiver survey designed to be filled out by a cat’s caregiver so it accurately describes a cat’s personality, background, and full range of behavior with people when in its normal environment. The results from this survey provided the basis for a socialization score that ranged from unsocialized to well socialized with people. The quality of the survey was evaluated based on inter-rater and test-retest reliability and internal consistency and estimates of construct and criterion validity. In general, our results showed moderate to high levels of inter-rater (median of 0.803, range 0.211–0.957 and test-retest agreement (median 0.92, range 0.211–0.999. Cronbach’s alpha showed high internal consistency (0.962. Estimates of validity did not highlight any major shortcomings. This survey will be used to develop and validate an effective assessment process that accurately differentiates cats by their socialization levels towards humans based on direct observation of cats’ behavior in an animal shelter.

  14. Simplified Asset Indices to Measure Wealth and Equity in Health Programs: A Reliability and Validity Analysis Using Survey Data From 16 Countries.

    Science.gov (United States)

    Chakraborty, Nirali M; Fry, Kenzo; Behl, Rasika; Longfield, Kim

    2016-03-01

    Social franchising programs in low- and middle-income countries have tried using the standard wealth index, based on the Demographic and Health Survey (DHS) questionnaire, in client exit interviews to assess clients' relative wealth compared with the national wealth distribution to ensure equity in service delivery. The large number of survey questions required to capture the wealth index variables have proved cumbersome for programs. Using an adaptation of the Delphi method, we developed shortened wealth indices and in February 2015 consulted 15 stakeholders in equity measurement. Together, we selected the best of 5 alternative indices, accompanied by 2 measures of agreement (percent agreement and Cohen's kappa statistic) comparing wealth quintile assignment in the new indices to the full DHS index. The panel agreed that reducing the number of assets was more important than standardization across countries because a short index would provide strong indication of client wealth and be easier to collect and use in the field. Additionally, the panel agreed that the simplified index should be highly correlated with the DHS for each country (kappa ≥ 0.75) for both national and urban-specific samples. We then revised indices for 16 countries and selected the minimum number of questions and question options required to achieve a kappa statistic ≥ 0.75 for both national and urban populations. After combining the 5 wealth quintiles into 3 groups, which the expert panel deemed more programmatically meaningful, reliability between the standard DHS wealth index and each of 3 simplified indices was high (median kappa = 0.81, 086, and 0.77, respectively, for index B that included only the common questions from the DHS VI questionnaire, index D that included the common questions plus country-specific questions, and index E that found the shortest list of common and country-specific questions that met the minimum reliability criteria of kappa ≥ 0.75). Index E was the

  15. Simplified Asset Indices to Measure Wealth and Equity in Health Programs: A Reliability and Validity Analysis Using Survey Data From 16 Countries

    Science.gov (United States)

    Chakraborty, Nirali M; Fry, Kenzo; Behl, Rasika; Longfield, Kim

    2016-01-01

    ABSTRACT Background: Social franchising programs in low- and middle-income countries have tried using the standard wealth index, based on the Demographic and Health Survey (DHS) questionnaire, in client exit interviews to assess clients’ relative wealth compared with the national wealth distribution to ensure equity in service delivery. The large number of survey questions required to capture the wealth index variables have proved cumbersome for programs. Methods: Using an adaptation of the Delphi method, we developed shortened wealth indices and in February 2015 consulted 15 stakeholders in equity measurement. Together, we selected the best of 5 alternative indices, accompanied by 2 measures of agreement (percent agreement and Cohen’s kappa statistic) comparing wealth quintile assignment in the new indices to the full DHS index. The panel agreed that reducing the number of assets was more important than standardization across countries because a short index would provide strong indication of client wealth and be easier to collect and use in the field. Additionally, the panel agreed that the simplified index should be highly correlated with the DHS for each country (kappa ≥ 0.75) for both national and urban-specific samples. We then revised indices for 16 countries and selected the minimum number of questions and question options required to achieve a kappa statistic ≥ 0.75 for both national and urban populations. Findings: After combining the 5 wealth quintiles into 3 groups, which the expert panel deemed more programmatically meaningful, reliability between the standard DHS wealth index and each of 3 simplified indices was high (median kappa = 0.81, 086, and 0.77, respectively, for index B that included only the common questions from the DHS VI questionnaire, index D that included the common questions plus country-specific questions, and index E that found the shortest list of common and country-specific questions that met the minimum reliability

  16. The Development of a Survey Instrument on South Dakota's School District Leadership Climate as Related to Deming's Fourteen Points.

    Science.gov (United States)

    Holmes, Lawrence W. O.; And Others

    Development of an instrument to measure baseline levels of applied Total Quality Management (TQM) practices in South Dakota before the introduction and dissemination of TQM theory to the state's educational leaders is described. Using the interpretation of Deming's 14 points that was developed by J. J. Bonstigl, a 115-item initial item pool was…

  17. Preliminary Validation and Reliability Testing of the Montreal Instrument for Cat Arthritis Testing, for Use by Veterinarians, in a Colony of Laboratory Cats

    Directory of Open Access Journals (Sweden)

    Mary P. Klinck

    2015-12-01

    Full Text Available Subtle signs and conflicting physical and radiographic findings make feline osteoarthritis (OA challenging to diagnose. A physical examination-based assessment was developed, consisting of eight items: Interaction, Exploration, Posture, Gait, Body Condition, Coat and Claws, (joint Palpation–Findings, and Palpation–Cat Reaction. Content (experts and face (veterinary students validity were excellent. Construct validity, internal consistency, and intra- and inter-rater reliability were assessed via a pilot and main study, using laboratory-housed cats with and without OA. Gait distinguished OA status in the pilot ( p = 0.05 study. In the main study, no scale item achieved statistically significant OA detection. Forelimb peak vertical ground reaction force (PVF correlated inversely with Gait (Rho s = −0.38 ( p = 0.03 to −0.41 ( p = 0.02. Body Posture correlated with Gait, and inversely with forelimb PVF at two of three time points (Rho s = −0.38 ( p = 0.03 to −0.43 ( p = 0.01. Palpation (Findings, Cat Reaction did not distinguish OA from non-OA cats. Palpation—Cat Reaction (Forelimbs correlated inversely with forelimb PVF at two time points (Rho s = −0.41 ( p = 0.02 to −0.41 ( p = 0.01, but scores were highly variable, and poorly reliable. Gait and Posture require improved sensitivity, and Palpation should be interpreted cautiously, in diagnosing feline OA.

  18. Survey of the possibilities to maintain correct measurements through increased reliability of components or through ''operational fault perceptibility''

    International Nuclear Information System (INIS)

    Volkmann, C.U.

    1982-12-01

    Tests and requirements for the pattern approval of mechanical weighing machines are based on long-term experience and detailed regulations, whereas equivalent treatment of electronic devices of weighing machines is a new kind of task. In this field experience is still scarce, and regulations are lacking. While there is some unanimity that the sensitivity of electronic devices to any kind of electromagnetic interferences has to be judged on the grounds of some tests, there is no universally accepted guideline as to how to assure, over a few weeks of pattern approval tests, the measuring stability for a period of years. Two major concepts are being followed to this end: increased reliability of components and ''operational fault perceptibility (OFP)''. After some remarks concerning the terminology to be used, both concepts are discussed and eventually compared. (orig.)

  19. The Cambridge Otology Quality of Life Questionnaire: an otology-specific patient-recorded outcome measure. A paper describing the instrument design and a report of preliminary reliability and validity.

    Science.gov (United States)

    Martin, T P C; Moualed, D; Paul, A; Ronan, N; Tysome, J R; Donnelly, N P; Cook, R; Axon, P R

    2015-04-01

    The Cambridge Otology Quality of Life Questionnaire (COQOL) is a patient-recorded outcome measurement (PROM) designed to quantify the quality of life of patients attending otology clinics. Item-reduction model. A systematically designed long-form version (74 items) was tested with patient focus groups before being presented to adult otology patients (n. 137). Preliminary item analysis tested reliability, reducing the COQOL to 24 questions. This was then presented in conjunction with the SF-36 (V1) questionnaire to a total of 203 patients. Subsequently, these were re-presented at T + 3 months, and patients recorded whether they felt their condition had improved, deteriorated or remained the same. Non-responders were contacted by post. A correlation between COQOL scores and patient perception of change was examined to analyse content validity. Teaching hospital and university psychology department. Adult patients attending otology clinics with a wide range of otological conditions. Item reliability measured by item–total correlation, internal consistency and test– retest reliability. Validity measured by correlation between COQOL scores and patient-reported symptom change. Reliability: the COQOL showed excellent internal consistency at both initial presentation (a = 0.90) and 3 months later (a = 0.93). Validity: One-way analysis of variance showed a significant difference between groups reporting change and those reporting no change in quality of life (F(2, 80) = 5.866, P < 0.01). The COQOL is the first otology-specific PROM. Initial studies demonstrate excellent reliability and encouraging preliminary criterion validity: further studies will allow a deeper validation of the instrument.

  20. An Assessment of the Effectiveness of Air Force Risk Management Practices in Program Acquisition Using Survey Instrument Analysis

    Science.gov (United States)

    2015-06-18

    Engineering Effectiveness Survey. CMU/SEI-2012-SR-009. Carnegie Mellon University. November 2012. Field, Andy. Discovering Statistics Using SPSS , 3rd...enough into the survey to begin answering questions on risk practices. All of the data statistical analysis will be performed using SPSS . Prior to...probabilistically using distributions for likelihood and impact. Statistical methods like Monte Carlo can more comprehensively evaluate the cost and

  1. Physical activity surveillance in the European Union: reliability and validity of the European Health Interview Survey-Physical Activity Questionnaire (EHIS-PAQ).

    Science.gov (United States)

    Baumeister, Sebastian E; Ricci, Cristian; Kohler, Simone; Fischer, Beate; Töpfer, Christine; Finger, Jonas D; Leitzmann, Michael F

    2016-05-23

    The current study examined the reliability and validity of the European Health Interview Survey-Physical Activity Questionnaire (EHIS-PAQ), a novel questionnaire for the surveillance of physical activity (PA) during work, transportation, leisure time, sports, health-enhancing and muscle-strengthening activities over a typical week. Reliability was assessed by administering the 8-item questionnaire twice to a population-based sample of 123 participants aged 15-79 years at a 30-day interval. Concurrent (inter-method) validity was examined in 140 participants by comparisons with self-report (International Physical Activity Questionnaire-Long Form (IPAQ-LF), 7-day Physical Activity Record (PAR), and objective criterion measures (GT3X+ accelerometer, physical work capacity at 75% (PWC(75%)) from submaximal cycle ergometer test, hand grip strength). The EHIS-PAQ showed acceptable reliability, with a median intraclass correlation coefficient across PA domains of 0.55 (range 0.43-0.73). Compared to the GT3X+ (counts/minutes/day), the EHIS-PAQ underestimated moderate-to-vigorous PA (median difference -11.7, p-value = 0.054). Spearman correlation coefficients (ρ) for validity were moderate-to-strong (ρ's > 0.41) for work-related PA (IPAQ = 0.64, GT3X + =0.43, grip strength = 0.48), transportation-related PA (IPAQ = 0.62, GT3X + =0.43), walking (IPAQ = 0.58), and health-enhancing PA (IPAQ = 0.58, PAR = 0.64, GT3X + =0.44, PWC(75%) = 0.48), and fair-to-poor (ρ's PAQ showed good evidence for reliability and validity for the measurement of PA levels at work, during transportation and health-enhancing PA.

  2. Preliminary Validation and Reliability Testing of the Montreal Instrument for Cat Arthritis Testing, for Use by Veterinarians, in a Colony of Laboratory Cats

    Science.gov (United States)

    Klinck, Mary P.; Rialland, Pascale; Guillot, Martin; Moreau, Maxim; Frank, Diane; Troncy, Eric

    2015-01-01

    Simple Summary Feline osteoarthritis (OA) is challenging to diagnose. A pain scale was developed for use by veterinarians, in association with their physical examination, and tested for reliability and validity. The scale items were: Interaction with the examiner, Exploration of the room, Body Posture, Gait, Body Condition, condition of Coat and Claws, and abnormal Findings or Cat Reaction upon joint Palpation. Expert review supported the scale content. Two studies using laboratory-housed cats found the most promising results for Gait and Body Posture, in terms of distinguishing between OA and non-OA cats, repeatability of results, and correlations with objectively measured kinetics (weight-bearing). Abstract Subtle signs and conflicting physical and radiographic findings make feline osteoarthritis (OA) challenging to diagnose. A physical examination-based assessment was developed, consisting of eight items: Interaction, Exploration, Posture, Gait, Body Condition, Coat and Claws, (joint) Palpation–Findings, and Palpation–Cat Reaction. Content (experts) and face (veterinary students) validity were excellent. Construct validity, internal consistency, and intra- and inter-rater reliability were assessed via a pilot and main study, using laboratory-housed cats with and without OA. Gait distinguished OA status in the pilot (p = 0.05) study. In the main study, no scale item achieved statistically significant OA detection. Forelimb peak vertical ground reaction force (PVF) correlated inversely with Gait (Rhos = −0.38 (p = 0.03) to −0.41 (p = 0.02)). Body Posture correlated with Gait, and inversely with forelimb PVF at two of three time points (Rhos = −0.38 (p = 0.03) to −0.43 (p = 0.01)). Palpation (Findings, Cat Reaction) did not distinguish OA from non-OA cats. Palpation—Cat Reaction (Forelimbs) correlated inversely with forelimb PVF at two time points (Rhos = −0.41 (p = 0.02) to −0.41 (p = 0.01)), but scores were highly variable, and poorly reliable

  3. Validity and reliability testing of two instruments to measure breast cancer patients' concerns and information needs relating to radiation therapy

    International Nuclear Information System (INIS)

    Halkett, Georgia KB; Kristjanson, Linda J

    2007-01-01

    It is difficult to determine the most effective approach to patient education or tailor education interventions for patients in radiotherapy without tools that assess patients' specific radiation therapy information needs and concerns. Therefore, the aim of this study was to develop psychometrically sound tools to adequately determine the concerns and information needs of cancer patients during radiation therapy. Two tools were developed to (1) determine patients concerns about radiation therapy (RT Concerns Scale) and (2) ascertain patient's information needs at different time point during their radiation therapy (RT Information Needs Scale). Tools were based on previous research by the authors, published literature on breast cancer and radiation therapy and information behaviour research. Thirty-one breast cancer patients completed the questionnaire on one occasion and thirty participants completed the questionnaire on a second occasion to facilitate test-retest reliability. One participant's responses were removed from the analysis. Results were analysed for content validity, internal consistency and stability over time. Both tools demonstrated high internal consistency and adequate stability over time. The nine items in the RT Concerns Scale were retained because they met all pre-set psychometric criteria. Two items were deleted from the RT Information Needs Scale because they did not meet content validity criteria and did not achieve pre-specified criteria for internal consistency. This tool now contains 22 items. This paper provides preliminary data suggesting that the two tools presented are reliable and valid and would be suitable for use in trials or in the clinical setting

  4. The balanced scorecard as a potential instrument for supporting planning and improvement in accounting education: Comparative survey findings

    Directory of Open Access Journals (Sweden)

    CJ Cronje

    2004-04-01

    Full Text Available This paper is firstly a comparison of the components of a potential balanced scorecard for accounting departments of universities in South Africa and Australia. Secondly, the various suggested measurement criteria of the balanced scorecard components are also compared. The findings of the research paper indicate no significant differences. The conclusion is that the balanced scorecard constitutes a potential instrument for supporting the planning and improvement of the accounting education environment.

  5. Reliability analysis and computation of computer-based safety instrumentation and control used in German nuclear power plant. Final report; Zuverlaessigkeitsuntersuchung und -berechnung rechnerbasierter Sicherheitsleittechnik zum Einsatz in deutschen Kernkraftwerken. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Yongjian [Hochschule Magdeburg-Stendal, Magdeburg (Germany). Inst. fuer Elektrotechnik; Krause, Ulrich [Magdeburg Univ. (Germany). Inst. fuer Apparate- und Umwelttechnik; Gu, Chunlei

    2014-08-21

    The trend of technological advancement in the field of safety instrumentation and control (I and C) leads to increasingly frequent use of computer-based (digital) control systems which consisting of distributed, connected bus communications computers and their functionalities are freely programmable by qualified software. The advantages of the new I and C system over the old I and C system with hard-wired technology are e.g. in the higher flexibility, cost-effective procurement of spare parts, higher hardware reliability (through higher integration density, intelligent self-monitoring mechanisms, etc.). On the other hand, skeptics see the new technology with the computer-based I and C a higher potential by influences of common cause failures (CCF), and the easier manipulation by sabotage (IT Security). In this joint research project funded by the Federal Ministry for Economical Affaires and Energy (BMWi) (2011-2014, FJZ 1501405) the Otto-von-Guericke-University Magdeburg and Magdeburg-Stendal University of Applied Sciences are therefore trying to develop suitable methods for the demonstration of the reliability of the new instrumentation and control systems with the focus on the investigation of CCF. This expertise of both houses shall be extended to this area and a scientific contribution to the sound reliability judgments of the digital safety I and C in domestic and foreign nuclear power plants. First, the state of science and technology will be worked out through the study of national and international standards in the field of functional safety of electrical and I and C systems and accompanying literature. On the basis of the existing nuclear Standards the deterministic requirements on the structure of the new digital I and C system will be determined. The possible methods of reliability modeling will be analyzed and compared. A suitable method called multi class binomial failure rate (MCFBR) which was successfully used in safety valve applications will be

  6. Reliability Engineering

    International Nuclear Information System (INIS)

    Lee, Sang Yong

    1992-07-01

    This book is about reliability engineering, which describes definition and importance of reliability, development of reliability engineering, failure rate and failure probability density function about types of it, CFR and index distribution, IFR and normal distribution and Weibull distribution, maintainability and movability, reliability test and reliability assumption in index distribution type, normal distribution type and Weibull distribution type, reliability sampling test, reliability of system, design of reliability and functionality failure analysis by FTA.

  7. Instruments for Water Quality Monitoring

    Science.gov (United States)

    Ballinger, Dwight G.

    1972-01-01

    Presents information regarding available instruments for industries and agencies who must monitor numerous aquatic parameters. Charts denote examples of parameters sampled, testing methods, range and accuracy of test methods, cost analysis, and reliability of instruments. (BL)

  8. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  9. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1985-01-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  10. Development of a Survey Instrument to Measure TEFL Academics' Perceptions about, Individual and Workplace Characteristics for Conducting Research

    Science.gov (United States)

    Bai, Li; Hudson, Peter; Millwater, Jan; Tones, Megan

    2013-01-01

    A 30-item survey was devised to determine Chinese TEFL (Teaching English as a Foreign Language) academics' potential for conducting research. A five-part Likert scale was used to gather data from 182 academics on four factors: (1) perceptions on teaching-research nexus, (2) personal perspectives for conducting research, (3) predispositions for…

  11. Study to determine the reliability and validity of a needs-assessment instrument used within the mechanical maintenance field of the nuclear electrical-generating industry

    International Nuclear Information System (INIS)

    Russell, L.O.

    1982-01-01

    This study was to determine if task parameter ratings provided by nuclear power plant maintenance mechanics assessed the true task frequency, criticality, and difficulty. This was to measure the data's usefulness as a training needs assessment indicator. A questionnaire entitled Job Task Questionnaire for Maintenance Mechanics was developed and used to collect data from job incumbents. Development was based on plant visits and incumbent interviews. Duties, tasks, parameters, and scales were then compiled to form the questionnaire. The questionnaire was then pilot tested. A random sample was selected from the national population of nuclear power plant maintenance mechanics. This resulted in a sample which was stratified across the job title and random within the job title. The descriptive analysis did not tend to indicate that the mean value of each task parameter provided a true or valid value. The overall conclusion drawn from the data analysis was that the ratings did not provide a substantially valid or reliable indication on which to base task training needs

  12. Human and organisational factors influencing the reliability of non-destructive testing. An international literary survey; Inhimillisten ja organisatoristen tekijoeiden yhteys NDT- tarkastusten luotettavuuteen. Katsaus kansainvaeliseen kirjallisuuteen

    Energy Technology Data Exchange (ETDEWEB)

    Kettunen, J.; Norros, L.

    1996-04-01

    The aim of the study is to chart human and organisational factors influencing the reliability of non-destructive testing (NDT). The emphasis will be in ultrasonic testing (UT) and in the planning and execution of in-service inspections during nuclear power plant maintenance outages. Being a literary survey this study is mainly based on the foreign and domestic research available on the topic. In consequence, the results presented in this report reflect the ideas of international research community. In addition to this, Finnish nuclear power plant operators (Imatran Voima Oy and Teollisuuden Voima Oy), independent inspection organisations and the Finnish Centre for Radiation and Nuclear Safety have provided us with valuable information on NDT theory and practice. Especially, a kind of `big picture` of non-destructive testing has been pursued in the study. (6 figs., 2 tabs.).

  13. The diversity of the human hair colour assessed by visual scales and instrumental measurements. A worldwide survey.

    Science.gov (United States)

    Lozano, I; Saunier, J B; Panhard, S; Loussouarn, G

    2017-02-01

    To study (i) the diversity of the natural colour of the human hair through both visual assessment of hair tone levels and colorimetric measurements of hair strands collected from 2057 human male and female volunteers, from 23 regions of the world and (ii) the correlation between visual assessments and colorimetric measurements. Hair strands were analysed by a spectrocolorimeter under the L*, a*, b* referential system and scored in vivo by experts before sampling, through standardized visual reference scales based on a 1-10 range. Results show that from a typological aspect, black or dark brown hairs largely predominate among studied ethnic groups, whereas Caucasian or derived populations exhibit the widest palette of medium to fair shades, partly explaining some past interbreeding among populations. Instrumental measurements clearly confirm that a given colour of a pigmented hair, at the exclusion of red hairs, is mostly governed by two components, L* and b*, from the L*, a*, b* reference system. The comparisons between visual assessments and instrumental data show that these appear closely linked. Darker hairs show close or subtle variations in L*, a*, b* parameters, making their individual colour differentiation calling for technical improvements in colorimetric measurements. The latter are likely governed by other physical factors such as shape, diameter and shine. © 2016 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  14. a Circleless "2D/3D Total STATION": a Low Cost Instrument for Surveying, Recording Point Clouds, Documentation, Image Acquisition and Visualisation

    Science.gov (United States)

    Scherer, M.

    2013-07-01

    Hardware and software of the universally applicable instrument - referred to as a 2D/3D total station - are described here, as well as its practical use. At its core it consists of a 3D camera - often also called a ToF camera, a pmd camera or a RIM-camera - combined with a common industrial 2D camera. The cameras are rigidly coupled with their optical axes in parallel. A new type of instrument was created mounting this 2D/3D system on a tripod in a specific way. Because of it sharing certain characteristics with a total station and a tacheometer, respectively, the new device was called a 2D/3D total station. It may effectively replace a common total station or a laser scanner in some respects. After a brief overview of the prototype's features this paper then focuses on the methodological characteristics for practical application. Its usability as a universally applicable stand-alone instrument is demonstrated for surveying, recording RGB-coloured point clouds as well as delivering images for documentation and visualisation. Because of its limited range (10m without reflector and 150 m to reflector prisms) and low range accuracy (ca. 2 cm to 3 cm) compared to present-day total stations and laser scanners, the practical usage of the 2D/3D total station is currently limited to acquisition of accidents, forensic purpuses, speleology or facility management, as well as architectural recordings with low requirements regarding accuracy. However, the author is convinced that in the near future advancements in 3D camera technology will allow this type of comparatively low cost instrument to replace the total station as well as the laser scanner in an increasing number of areas.

  15. The role and reliability of the Psychopathy Checklist-Revised in U.S. sexually violent predator evaluations: a case law survey.

    Science.gov (United States)

    DeMatteo, David; Edens, John F; Galloway, Meghann; Cox, Jennifer; Smith, Shannon Toney; Formon, Dana

    2014-06-01

    The civil commitment of offenders as sexually violent predators (SVPs) is a highly contentious area of U.S. mental health law. The Psychopathy Checklist-Revised (PCL-R) is frequently used in mental health evaluations in these cases to aid legal decision making. Although generally perceived to be a useful assessment tool in applied settings, recent research has raised questions about the reliability of PCL-R scores in SVP cases. In this report, we review the use of the PCL-R in SVP trials identified as part of a larger project investigating its role in U.S. case law. After presenting data on how the PCL-R is used in SVP cases, we examine the reliability of scores reported in these cases. We located 214 cases involving the PCL-R, 88 of which included an actual score and 29 of which included multiple scores. In the 29 cases with multiple scores, the intraclass correlation coefficient for a single evaluator for the PCL-R scores was only .58, and only 41.4% of the difference scores were within 1 standard error of measurement unit. The average score reported by prosecution experts was significantly higher than the average score reported by defense-retained experts, and prosecution experts reported PCL-R scores of 30 or above in nearly 50% of the cases, compared with less than 10% of the cases for defense witnesses (κ = .29). In conjunction with other recently published findings demonstrating the unreliability of PCL-R scores in applied settings, our results raise questions as to whether this instrument should be admitted into SVP proceedings.

  16. Survey of the state-of-the-art in aging of electronics with application to nuclear-power-plant instrumentation

    International Nuclear Information System (INIS)

    Johnson, R.T. Jr.; Thome, F.V.; Craft, C.M.

    1983-04-01

    The purpose of this report is to present results of a study to evaluate the state-of-the-art and outline needed research on aging of electronics in nuclear power plants. The emphasis is on aging of electronics (e.g., semiconductors, capacitors, resistors) used in safety-related Class 1E instrumentation, particularly those used in harsh environments. Some attention is also given to encapsulants, printed circuit boards and bonds (e.g., solder joints) since they are integral parts of circuits. Four major tasks were addressed in this study and are the subject of this report. These include (1) selecting candidate electronic components for study and review; (2) defining the aging environment and initiating an effort to determine the state-of-the-art in aging degradation; (3) recommending follow-on investigations and research; and (4) outlining the first steps in defining a program on accelerated aging

  17. Confiabilidade do Instrumento para Classificação de Idosos quanto à Capacidade para o Autocuidado Reliability of the Instrument for Classifying Elderly People's Capacity for Self-care

    Directory of Open Access Journals (Sweden)

    Maria Helena Morgani de Almeida

    2008-04-01

    Full Text Available OBJETIVO: Avaliar a confiabilidade do Instrumento para Classificação de Idosos quanto à Capacidade para o Autocuidado, desenvolvido para auxiliar o terapeuta ocupacional na atenção a idosos em unidades básicas de saúde. MÉTODOS: Foram realizados testes de estabilidade e consistência interna. Para validação do Instrumento, os testes foram aplicados à amostra de 30 indivíduos com 60 anos ou mais, em dois momentos. A análise estatística foi realizada a partir de agrupamentos criteriosos de respostas, o que levou à formulação de uma versão simplificada do Instrumento. A estabilidade desta versão foi avaliada pelo coeficiente kappa e a consistência interna pelo coeficiente alpha de Cronbach. RESULTADOS: A estabilidade variou de moderada a excelente. A consistência interna foi verificada somente para áreas que se mostraram adequadas para o uso da metodologia baseada no cálculo do alpha de Cronbach: três das seis questões da área "perfil social" e os blocos das atividades básicas e instrumentais de vida diária da área "capacidade funcional", respectivamente com nove e oito atividades. CONCLUSÕES: Após os testes de estabilidade e consistência interna, o Instrumento possibilita classificação sucinta e simplificada de idosos quanto à capacidade funcional para atividades básicas e instrumentais e sua caracterização quanto aos demais aspectos do autocuidado. Evidências acerca de sua confiabilidade e validade podem ser ampliadas por meio de novos estudos.OBJECTIVE: To evaluate the reliability of an instrument for classifying elderly people regarding their capacity for self-care, which was developed to assist occupational therapists in attending elderly people at primary healthcare units. METHODS: Stability and internal consistency tests were carried out. To validate the instrument, tests were applied to a sample of 30 individuals aged 60 years and over, on two occasions. The statistical analysis was performed after

  18. Hybrid instrument applied to human reliability study in event of loss of external electric power in a nuclear power plant; Instrumento hibrido aplicado ao estudo da confiabilidade humana em evento de perda de energia eletrica externa em usina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Eduardo Ferraz

    2015-04-01

    The study projects in highly complex installations involves robust modeling, supported by conceptual and mathematical tools, to carry out systematic research and structured the different risk scenarios that can lead to unwanted events from occurring equipment failures or human errors. In the context of classical modeling, the Probabilistic Safety Analysis (PSA) seeks to provide qualitative and quantitative information about the project particularity and their operational facilities, including the identification of factors or scenarios that contribute to the risk and consequent comparison options for increasing safety. In this context, the aim of the thesis is to develop a hybrid instrument (CPP-HI) innovative, from the integrated modeling techniques of Failure Mode and Effect Analysis (FMEA), concepts of Human Reliability Analysis and Probabilistic Composition of Preferences (PCP). In support of modeling and validation of the CPP-HI, a simulation was performed on a triggering event 'Loss of External Electric Power' - PEEE, in a Nuclear Power plant. The results were simulated in a virtual environment (sensitivity analysis) and are robust to the study of Human Reliability Analysis (HRA) in the context of the PSA. (author)

  19. The Swiss Health Literacy Survey: development and psychometric properties of a multidimensional instrument to assess competencies for health

    Science.gov (United States)

    Wang, Jen; Thombs, Brett D.; Schmid, Margareta R.

    2012-01-01

    Abstract Background  Growing recognition of the role of citizens and patients in health and health care has placed a spotlight on health literacy and patient education. Objective  To identify specific competencies for health in definitions of health literacy and patient‐centred concepts and empirically test their dimensionality in the general population. Methods  A thorough review of the literature on health literacy, self‐management, patient empowerment, patient education and shared decision making revealed considerable conceptual overlap as competencies for health and identified a corpus of 30 generic competencies for health. A questionnaire containing 127 items covering the 30 competencies was fielded as a telephone interview in German, French and Italian among 1255 respondents randomly selected from the resident population in Switzerland. Findings  Analyses with the software MPlus to model items with mixed response categories showed that the items do not load onto a single factor. Multifactorial models with good fit could be erected for each of five dimensions defined a priori and their corresponding competencies: information and knowledge (four competencies, 17 items), general cognitive skills (four competencies, 17 items), social roles (two competencies, seven items), medical management (four competencies, 27 items) and healthy lifestyle (two competencies, six items). Multiple indicators and multiple causes models identified problematic differential item functioning for only six items belonging to two competencies. Conclusions  The psychometric analyses of this instrument support broader conceptualization of health literacy not as a single competence but rather as a package of competencies for health. PMID:22390287

  20. The Swiss Health Literacy Survey: development and psychometric properties of a multidimensional instrument to assess competencies for health.

    Science.gov (United States)

    Wang, Jen; Thombs, Brett D; Schmid, Margareta R

    2014-06-01

    Growing recognition of the role of citizens and patients in health and health care has placed a spotlight on health literacy and patient education. To identify specific competencies for health in definitions of health literacy and patient-centred concepts and empirically test their dimensionality in the general population. A thorough review of the literature on health literacy, self-management, patient empowerment, patient education and shared decision making revealed considerable conceptual overlap as competencies for health and identified a corpus of 30 generic competencies for health. A questionnaire containing 127 items covering the 30 competencies was fielded as a telephone interview in German, French and Italian among 1255 respondents randomly selected from the resident population in Switzerland. Analyses with the software MPlus to model items with mixed response categories showed that the items do not load onto a single factor. Multifactorial models with good fit could be erected for each of five dimensions defined a priori and their corresponding competencies: information and knowledge (four competencies, 17 items), general cognitive skills (four competencies, 17 items), social roles (two competencies, seven items), medical management (four competencies, 27 items) and healthy lifestyle (two competencies, six items). Multiple indicators and multiple causes models identified problematic differential item functioning for only six items belonging to two competencies. The psychometric analyses of this instrument support broader conceptualization of health literacy not as a single competence but rather as a package of competencies for health. © 2012 John Wiley & Sons Ltd.

  1. Characteristics of protective instrumentation

    International Nuclear Information System (INIS)

    Reichart, G.

    1982-01-01

    Protective Instrumentation (PI) for Nuclear Power Plants (NPP) is a general term for an highly reliable instrumentation, which provides information for keeping the system within safe limits, for initation of countermeasures in the case of an incident or for mitigation of consequences of an accident. In German NPPs one can find a hierarchical structure of protective instrumentation, wherein the Reactor Protection System (RPS) has the highest priority. To meet the reliability requirements different design principles are used, like - redundancy - diversity - fail safe - decoupling. The presentation gives an overview about the different design principles and characterizes their reliability aspects. As an example for the technical realization the RPS of a German NPP is discussed in some detail. Furthermore some information about other type of PI is given and reliability aspects of the interaction of operating personell with these systems are mentioned. (orig.)

  2. Abnormal condition and events analysis for instrumentation and control systems. Volume 2: Survey and evaluation of industry practices. Final report

    International Nuclear Information System (INIS)

    McKemy, S.; Marcelli, M.; Boehmer, N.; Crandall, D.

    1996-01-01

    The ACES Project was initiated to identify a cost-effective methodology for addressing abnormal conditions and events (ACES) in digital upgrades to nuclear power plant systems, as introduced by IEEE Standard 7-4.3.2-1993. Several methodologies and techniques currently in use in the defense, aerospace, and other communities for the assurance of digital safety systems were surveyed, and although several were shown to possess desirable qualities, none sufficiently met the needs of the nuclear power industry. This report describes a tailorable methodology for performing ACES analysis that is based on the more desirable aspects of the reviewed methodologies and techniques. The methodology is applicable to both safety- and non-safety-grade systems, addresses hardware, software, and system-level concerns, and can be applied in either a lifecycle or post-design timeframe. Employing this methodology for safety systems should facilitate the digital upgrade licensing process

  3. Laser-Scanner Survey of Structural Disorders: AN Instrument to Inspect the History of Parma Cathedral's Central Nave

    Science.gov (United States)

    Bruno, N.; Coïsson, E.; Cotti, M.

    2017-05-01

    This paper presents the use of laser scanner derived data for the study of the structural disorders in the central nave of the Parma Cathedral. An accurate three-dimensional model of the entire nave was realized to investigate deformations, in order to reconstruct the original conformation and the subsequent evolutions, also in comparison with previous surveys. Specifically, for the analysis presented in the paper, seven scans were performed, one for each bay: the results allowed to compare the deformations on the seven vaults, on the transverse and diagonal arches, giving first hints on the possible differences in the behaviour between the different elements. The measures on the levels of floor and pillars bases were analysed in a historical monitoring approach, in order to retrace the evolution of the differential settlements in time, since the construction of the building. Moreover, a structural analysis has been carried out on one transverse arch with distinct element analysis, with two different approaches. In one case, the structure was inserted exactly as surveyed, and then subjected to the actions. In the second case, the original geometry, before the deformation, was retraced through a parametric approach and the structural analysis basically started at the beginning of the building's life, thus trying to model not only the present structural situation, but also the path which led to the current deformation. The results were particularly meaningful as they showed that in the first case, disregarding the footsteps of history, the stress pattern inside the masonry was very different from the one obtained in the second case, which is more likely to represent the present conditions.

  4. A new algorithm to build bridges between two patient-reported health outcome instruments: the MOS SF-36® and the VR-12 Health Survey.

    Science.gov (United States)

    Selim, Alfredo; Rogers, William; Qian, Shirley; Rothendler, James A; Kent, Erin E; Kazis, Lewis E

    2018-04-19

    To develop bridging algorithms to score the Veterans Rand-12 (VR-12) scales for comparability to those of the SF-36® for facilitating multi-cohort studies using data from the National Cancer Institute Surveillance, Epidemiology, and End Results Program (SEER) linked to Medicare Health Outcomes Survey (MHOS), and to provide a model for minimizing non-statistical error in pooled analyses stemming from changes to survey instruments over time. Observational study of MHOS cohorts 1-12 (1998-2011). We modeled 2-year follow-up SF-36 scale scores from cohorts 1-6 based on baseline SF-36 scores, age, and gender, yielding 100 clusters using Classification and Regression Trees. Within each cluster, we averaged follow-up SF-36 scores. Using the same cluster specifications, expected follow-up SF-36 scores, based on cohorts 1-6, were computed for cohorts 7-8 (where the VR-12 was the follow-up survey). We created a new criterion validity measure, termed "extensibility," calculated from the square root of the mean square difference between expected SF-36 scale averages and observed VR-12 item score from cohorts 7-8, weighted by cluster size. VR-12 items were rescored to minimize this quantity. Extensibility of rescored VR-12 items and scales was considerably improved from the "simple" scoring method for comparability to the SF-36 scales. The algorithms are appropriate across a wide range of potential subsamples within the MHOS and provide robust application for future studies that span the SF-36 and VR-12 eras. It is possible that these surveys in a different setting outside the MHOS, especially in younger age groups, could produce somewhat different results.

  5. Reliability data book

    International Nuclear Information System (INIS)

    Bento, J.P.; Boerje, S.; Ericsson, G.; Hasler, A.; Lyden, C.O.; Wallin, L.; Poern, K.; Aakerlund, O.

    1985-01-01

    The main objective for the report is to improve failure data for reliability calculations as parts of safety analyses for Swedish nuclear power plants. The work is based primarily on evaluations of failure reports as well as information provided by the operation and maintenance staff of each plant. In the report are presented charts of reliability data for: pumps, valves, control rods/rod drives, electrical components, and instruments. (L.E.)

  6. Fine-scale environmental effects on Cape hake survey catch rates in the Northern Benguela, using data from a trawl-mounted instrument package

    DEFF Research Database (Denmark)

    Kainge, Paulus Inekela; Wieland, Kai

    2017-01-01

    We investigated fine-scale effects of environmental variables associated with habitat distribution for 4 size groups of Cape hakes, Merluccius capensis and M. paradoxus, using generalized additive models (GAMs) with a negative binominal error distribution. This study took place during the Namibian...... hake trawl survey of 2016, and was made possible for the first time in Namibia by collecting oceanographic information with a trawl-mounted instrument package concurrently with the catch data. Depth, geographical position, bottom oxygen and bottom temperature had the most pronounced effect on the catch...... rates of both hake species, whereas solar zenith angle representing diel effects and surface layer chlorophyll appeared to be less important. The explained deviance for the best models ranged from 71.4% for M. capensis to 92.7% for M. paradoxus between 43 and 57 cm in length. Differences in catch rates...

  7. National Survey on Internal Quality Control for HbA(1c) Analytical Instruments in 331 Hospital Laboratories of China.

    Science.gov (United States)

    Zeng, Rong; Wang, Wei; Zhao, Haijian; Fei, Yang; Wang, Zhiguo

    2015-01-01

    The narrow gap of HbA1 value of mass fraction between "normal" (control of inter-assay standardization, assay precision, and trueness. This survey was initiated to obtain knowledge of the current situation of internal quality control (IQC) practice for HbA(1c) in China and find out the most appropriate quality specifications. Data of IQC for HbA(1c) in 331 institutions participating in the national proficiency testing (PT) programs in China were evaluated using four levels of quality specifications, and the percentages of laboratories meeting the quality requirement were calculated to find out the most appropriate quality specifications for control materials of HbA(1c) in China. The IQC data varied vastly among 331 clinical laboratories in China. The measurement of control materials covered a wide range from 4.52% to 12.24% (inter-quartile range) and there were significant differences among the CVs of different methods, including LPLC, CE-HPLC, AC-HPLC, immunoturbidimetry, and others. Among the four main methods, CE-HPLC and AC-HPLC achieved a better precision. As we can see, the performance of laboratories for HbA(1c) has yet to be improved. Clinical laboratories in China should improve their performance with a stricter imprecision criteria.

  8. A Survey of the Rapidly Emerging Field of Nanotechnology: Potential Applications for Scientific Instruments and Technologies for Atmospheric Entry Probes

    Science.gov (United States)

    Meyyappan, M.; Arnold, J. O.

    2005-01-01

    The field of Nanotechnology is well funded worldwide and innovations applicable to Solar System Exploration are emerging much more rapidly than thought possible just a few years ago. This presentation will survey recent innovations from nanotechnololgy with a focus on novel applications to atmospheric entry science and probe technology, in a fashion similar to that presented by Arnold and Venkatapathy at the previous workshop forum at Lisbon Portugal, October 6-9, 2003. Nanotechnology is a rapidly emerging field that builds systems, devices and materials from the bottom up, atom by atom, and in so doing provides them with novel and remarkable macro-scale performance. This technology has the potential to revolutionize space exploration by reducing mass and simultaneously increasing capability. Thermal, Radiation, Impact Protective Shields: Atmospheric probes and humans on long duration deep space missions involved in Solar System Exploration must safely endure 3 significant hazards: (i) atmospheric entry; (ii) radiation; and (iii) micrometeorite or debris impact. Nanostructured materials could be developed to address all three hazards with a single protective shield, which would involve much less mass than a traditional approach. The concept can be ready in time for incorporation into NASA s Crew Exploration Vehicle, and possible entry probes to fly on the Jupiter Icy Moons

  9. Measuring decision quality: psychometric evaluation of a new instrument for breast cancer surgery

    Directory of Open Access Journals (Sweden)

    Sepucha Karen R

    2012-06-01

    Full Text Available Abstract Background The purpose of this paper is to examine the acceptability, feasibility, reliability and validity of a new decision quality instrument that assesses the extent to which patients are informed and receive treatments that match their goals. Methods Cross-sectional mail survey of recent breast cancer survivors, providers and healthy controls and a retest survey of survivors. The decision quality instrument includes knowledge questions and a set of goals, and results in two scores: a breast cancer surgery knowledge score and a concordance score, which reflects the percentage of patients who received treatments that match their goals. Hypotheses related to acceptability, feasibility, discriminant validity, content validity, predictive validity and retest reliability of the survey instrument were examined. Results We had responses from 440 eligible patients, 88 providers and 35 healthy controls. The decision quality instrument was feasible to implement in this study, with low missing data. The knowledge score had good retest reliability (intraclass correlation coefficient = 0.70 and discriminated between providers and patients (mean difference 35%, p  Conclusions The decision quality instrument met the criteria of feasibility, reliability, discriminant and content validity in this sample. Additional research to examine performance of the instrument in prospective studies and more diverse populations is needed.

  10. Accuracy improvements of gyro-based measurement-while-drilling surveying instruments by a laser testing method

    Science.gov (United States)

    Li, Rong; Zhao, Jianhui; Li, Fan

    2009-07-01

    Gyroscope used as surveying sensor in the oil industry has been proposed as a good technique for measurement-whiledrilling (MWD) to provide real-time monitoring of the position and the orientation of the bottom hole assembly (BHA).However, drifts in the measurements provided by gyroscope might be prohibitive for the long-term utilization of the sensor. Some usual methods such as zero velocity update procedure (ZUPT) introduced to limit these drifts seem to be time-consuming and with limited effect. This study explored an in-drilling dynamic -alignment (IDA) method for MWD which utilizes gyroscope. During a directional drilling process, there are some minutes in the rotary drilling mode when the drill bit combined with drill pipe are rotated about the spin axis in a certain speed. This speed can be measured and used to determine and limit some drifts of the gyroscope which pay great effort to the deterioration in the long-term performance. A novel laser assembly is designed on the wellhead to count the rotating cycles of the drill pipe. With this provided angular velocity of the drill pipe, drifts of gyroscope measurements are translated into another form that can be easy tested and compensated. That allows better and faster alignment and limited drifts during the navigation process both of which can reduce long-term navigation errors, thus improving the overall accuracy in INS-based MWD system. This article concretely explores the novel device on the wellhead designed to test the rotation of the drill pipe. It is based on laser testing which is simple and not expensive by adding a laser emitter to the existing drilling equipment. Theoretical simulations and analytical approximations exploring the IDA idea have shown improvement in the accuracy of overall navigation and reduction in the time required to achieve convergence. Gyroscope accuracy along the axis is mainly improved. It is suggested to use the IDA idea in the rotary mode for alignment. Several other

  11. Validación de un cuestionario para el estudio del comportamiento sexual, social y corporal, de adolescentes escolares Validity and reliability of an instrument for assessing the social, and corporal sexual behaviors among school adolescents

    Directory of Open Access Journals (Sweden)

    Alfredo Hidalgo-San Martín

    2003-01-01

    Full Text Available OBJETIVO: Validar un cuestionario autoadministrado de comportamientos sexuales, sociales y corporales para adolescentes por nivel escolar y género. MATERIAL Y MÉTODOS: Instrumento de 26 preguntas construido según DeVellis, aplicado en un estudio longitudinal prospectivo, hecho en 1994 a 1 243 alumnos y alumnas de secundaria y preparatoria en Guadalajara, Jalisco, México. Validez de constructo establecida por análisis factorial exploratorio y la confiabilidad por la prueba Alfa de Cronbach. RESULTADOS: Aparecen cinco factores en hombres usando valores propios (eigenvalue >1 y cinco en mujeres, forzando la mejor solución. Veinte factores explican entre 59.3 y 70.6% de varianza, con promedio de pesos factoriales de 0.63- 0.75, y con 13 factores diferentes. El promedio de Alfa de Cronbach fue de 0.87-0.93 y en 16 factores hubo valores de Alpha de 0.71 o más. CONCLUSIONES: Cuestionario para poblaciones equivalentes con validez de constructo y confiabilidad interna aceptables.OBJECTIVE: To validate a self-administered questionnaire about social and corporal sexual behaviors among adolescents, by school level and gender. MATERIAL AND METHODS: The data collection instrument was constructed according to DeVellis and consisted of 26 items. It was used in a prospective longitudinal study conducted in 1994 in Guadalajara, Mexico, among 1243 secondary and high school students. The construct validity of the instrument was established using exploratory factorial analysis, and its reliability using the Cronbach's alpha test. RESULTS: Five factors were obtained in males and an equal number in women, using eigenvalues >1 and by forcing the best solution. The explained variance was 59.3-70.6%; the factorial weight average was 0.63-0.75, and 13 different factors were selected. The Cronbach's alpha mean was 0.87-0.93 and 16 factors had Cronbach's alpha over 0.70. CONCLUSIONS: The instrumen has an acceptable validity and reliability for studying the sexual

  12. Validity and reliability of an instrument to measure barriers to bike use in adults. http://dx.doi.org/10.5007/1980-0037.2012v14n6p624

    Directory of Open Access Journals (Sweden)

    Marilson Kienteka

    2012-11-01

    Full Text Available The purpose of this study was to analyze the validity and reliability of an instru­ment to assess the perception of barriers related to bicycling for leisure and transportation in adults. The items composing the instrument were selected from the literature review on the subject. Content validity was analyzed by consulting experts in physical activity field. The reliability was assessed through internal consistency (Cronbach’s alpha and agreement (intraclass correlation coefficient (ICC, kappa coefficient and relative agreement in a sample of 66 adults (18-79 years old selected from three census tracts in Curitiba-PR. Data were analyzed using SPSS 17.0, with a significance level of 5%. Most of the sample consisted of women (60%, aged 40 years (47% and intermediate socioeconomic level (68%. The fre­quency of bicycling in leisure time was higher than for transportation means (15.2 vs 7.6%. The internal consistency (Cronbach’s alpha was significant, both in leisure time (α=0.77 and transportation (α=0.82. The agreement was higher for leisure (80.3 to 93.9% than compared to commuting (76.9 to 90.8%. Kappa values were moderate to high (leisure: 0.41 to 0.82: commuting: 0.53 to 0.82. The ICC sub-scores were 0.93 (CI95%: 0.88 to 0.96 and 0.89 (CI95%: 0.82 to 0.94 for leisure and transport, respectively. It follows that the instru­ment has psychometric quality suitable for measuring the barriers to bicycle use in adults.

  13. Assessing Academic Advising Outcomes Using Social Cognitive Theory: A Validity and Reliability Study

    Science.gov (United States)

    Erlich, Richard J.; Russ-Eft, Darlene F.

    2012-01-01

    The validity and reliability of three instruments, the "Counselor Rubric for Gauging Student Understanding of Academic Planning," micro-analytic questions, and the "Student Survey for Understanding Academic Planning," all based on social cognitive theory, were tested as means to assess self-efficacy and self-regulated learning in college academic…

  14. Discriminant validity, responsiveness and reliability of the arthritis-specific Work Productivity Survey assessing workplace and household productivity in patients with psoriatic arthritis

    Science.gov (United States)

    2014-01-01

    Introduction The novel arthritis-specific Work Productivity Survey (WPS) was developed to estimate patient productivity limitations associated with arthritis within and outside the home, which is an unmet need in psoriatic arthritis (PsA). The WPS has been validated in rheumatoid arthritis. This report assesses the discriminant validity, responsiveness and reliability of the WPS in adult-onset PsA. Methods Psychometric properties were assessed using data from the RAPID-PsA trial (NCT01087788) investigating certolizumab pegol (CZP) efficacy and safety in PsA. WPS was completed at baseline and every 4 weeks until Week 24. Validity was evaluated at baseline via known-groups defined using first and third quartiles of patients’ Disease Activity Score 28 based on C-reactive protein (DAS28(CRP)), Health Assessment Questionnaire-Disability Index (HAQ-DI), Short Form-36 (SF-36) items and PsA Quality of Life (PsAQoL) scores. Responsiveness and reliability were assessed by comparing WPS mean changes at Week 12 in American College of Rheumatology 20% improvement criteria (ACR20) or HAQ-DI Minimal Clinically Important Difference (MCID) 0.3 responders versus non-responders, as well as using standardized response means (SRM). All comparisons were conducted on the observed cases in the Randomized Set, regardless of the randomization group, using a non-parametric bootstrap-t method. Results Compared with patients with a better health state, patients with a worse health state had on average 2 to 6 times more household work days lost, more days with reduced household productivity, more days missed of family/social/leisure activities, more days with outside help hired and a significantly higher interference of arthritis per month. Among employed patients, those with a worse health state had 2 to 4 times more workplace days lost, more days with patient workplace productivity reduced, and a significantly higher interference of arthritis on patient workplace productivity versus

  15. Principles of survey development for telemedicine applications.

    Science.gov (United States)

    Demiris, George

    2006-01-01

    Surveys can be used in the evaluation of telemedicine applications but they must be properly designed, consistent and accurate. The purpose of the survey and the resources available will determine the extent of testing that a survey instrument should undergo prior to its use. The validity of an instrument is the correspondence between what is being measured and what was intended to be measured. The reliability of an instrument describes the 'consistency' or 'repeatability' of the measurements made with it. Survey instruments should be designed and tested following basic principles of survey development. The actual survey administration also requires consideration, for example data collection and processing, as well as the interpretation of the findings. Surveys are of two different types. Either they are self-administered, or they are administered by interview. In the latter case, they may be administered by telephone or in a face-to-face meeting. It is important to design a survey instrument based on a detailed definition of what it intends to measure and to test it before administering it to the larger sample.

  16. Instrumentation for environmental monitoring: biomedical

    International Nuclear Information System (INIS)

    1979-05-01

    An update is presented to Volume four of the six-volume series devoted to a survey of instruments useful for measurements in biomedicine related to environmental research and monitoring. Results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Methods of detection and analysis of gaseous organic pollutants and metals, including Ni and As are presented. Instrument techniques and notes are included on atomic spectrometry and uv and visible absorption instrumentation

  17. Environment for the instruments

    International Nuclear Information System (INIS)

    Ambro, P.

    1992-01-01

    A properly conditioned AC power supply is necessary for reliable functioning of instruments. Electric mains power is produced primarily for industry, workshops, lighting and household uses. Its quality is adjusted to these uses. In areas sand countries with a fast growing demand for electric power, these requirements are far from being met. Electronic instruments and computers, especially in these countries, need protection against disturbances of the mains supply. A clean and dry environment is needed for reliable functioning and long life of instruments. High humidity, specially at higher temperatures, changes the characteristics of electronic components. Moreover, under these conditions fungal growth causes leakage of currents and corrosion causes poor contacts. The presence of dust enhances these effects. They give rise to malfunction of instruments, particularly of high voltage equipment

  18. Environment for the instruments

    Energy Technology Data Exchange (ETDEWEB)

    Ambro, P

    1993-12-31

    A properly conditioned AC power supply is necessary for reliable functioning of instruments. Electric mains power is produced primarily for industry, workshops, lighting and household uses. Its quality is adjusted to these uses. In areas sand countries with a fast growing demand for electric power, these requirements are far from being met. Electronic instruments and computers, especially in these countries, need protection against disturbances of the mains supply. A clean and dry environment is needed for reliable functioning and long life of instruments. High humidity, specially at higher temperatures, changes the characteristics of electronic components. Moreover, under these conditions fungal growth causes leakage of currents and corrosion causes poor contacts. The presence of dust enhances these effects. They give rise to malfunction of instruments, particularly of high voltage equipment

  19. Effect of changes in a food frequency questionnaire: comparing data from two national dietary survey instruments among 12-month-old infants.

    Science.gov (United States)

    Kristiansen, Anne Lene; Laugsand Lillegaard, Inger Therese; Frost Andersen, Lene

    2013-07-24

    National dietary surveys among Norwegian 12-months olds have been conducted twice: in 1999 and 2007. At both time-points diet were assessed by a semi-quantitative food frequency questionnaire (SFFQ) (the SFFQ-1999 and the SFFQ-2007). Modifications in the SFFQ-2007 compared to the SFFQ-1999 have been made; therefore, the objective of the present study has been to explore the comparability of the data obtained by the two questionnaires. Moreover, reliability of maternal recall of infant feeding practices was assessed. Three hundred Norwegian infants born in April 2007 were invited to participate by completing both the SFFQ-1999 and the SFFQ-2007. An invitation letter and one of two questionnaires were sent by mail to the mother/parents about two weeks before the child turned 12 months of age. The study had a cross-over design where half of the sample received the SFFQ-1999 first and then about 2-3 weeks later they received the SFFQ-2007. The second half received the SFFQ-2007 first, and then 2-3 weeks later they received the SFFQ-1999. Ninety three participants completed both questionnaires (SFFQ-1999 and SFFQ-2007). For nutrients, the largest significant differences between the questionnaires were found for intake of vitamin D and added sugar, where added sugar was reported lower and vitamin D was reported higher with the SFFQ-2007 compared to the SFFQ-1999. For food items, lower intake of yoghurt and higher intake of vegetables and fish were observed with the SFFQ-2007 compared to the SFFQ-1999. In addition, reliable answers with regard to breastfeeding status, age for breastfeeding cessation and age for introducing solid foods were found. There was reasonable comparability between the two questionnaires for most nutrients and foods. The differences between the two questionnaires could mainly be explained by modifications that had occurred over time, where changes in the food composition databases used and especially changes in commercial recipes with regard to

  20. Software reliability

    CERN Document Server

    Bendell, A

    1986-01-01

    Software Reliability reviews some fundamental issues of software reliability as well as the techniques, models, and metrics used to predict the reliability of software. Topics covered include fault avoidance, fault removal, and fault tolerance, along with statistical methods for the objective assessment of predictive accuracy. Development cost models and life-cycle cost models are also discussed. This book is divided into eight sections and begins with a chapter on adaptive modeling used to predict software reliability, followed by a discussion on failure rate in software reliability growth mo

  1. Using New Technologies for Time Diary Data Collection: Instrument Design and Data Quality Findings from a Mixed-Mode Pilot Survey.

    Science.gov (United States)

    Chatzitheochari, Stella; Fisher, Kimberly; Gilbert, Emily; Calderwood, Lisa; Huskinson, Tom; Cleary, Andrew; Gershuny, Jonathan

    2018-01-01

    Recent years have witnessed a steady growth of time-use research, driven by the increased research and policy interest in population activity patterns and their associations with long-term outcomes. There is recent interest in moving beyond traditional paper-administered time diaries to use new technologies for data collection in order to reduce respondent burden and administration costs, and to improve data quality. This paper presents two novel diary instruments that were employed by a large-scale multi-disciplinary cohort study in order to obtain information on the time allocation of adolescents in the United Kingdom. A web-administered diary and a smartphone app were created, and a mixed-mode data collection approach was followed: cohort members were asked to choose between these two modes, and those who were unable or refused to use the web/app modes were offered a paper diary. Using data from a pilot survey of 86 participants, we examine diary data quality indicators across the three modes. Results suggest that the web and app modes yield an overall better time diary data quality than the paper mode, with a higher proportion of diaries with complete activity and contextual information. Results also show that the web and app modes yield a comparable number of activity episodes to the paper mode. These results suggest that the use of new technologies can improve diary data quality. Future research using larger samples should systematically investigate selection and measurement effects in mixed-mode time-use survey designs.

  2. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. V. TOWARD AN EMPIRICAL METAL-POOR MASS–LUMINOSITY RELATION

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Van Altena, William F.; Demarque, Pierre; Howell, Steve B.; Everett, Mark E.; Ciardi, David R.; Teske, Johanna K.; Henry, Todd J.; Winters, Jennifer G.

    2015-01-01

    In an effort to better understand the details of the stellar structure and evolution of metal-poor stars, the Gemini North telescope was used on two occasions to take speckle imaging data of a sample of known spectroscopic binary stars and other nearby stars in order to search for and resolve close companions. The observations were obtained using the Differential Speckle Survey Instrument, which takes data in two filters simultaneously. The results presented here are of 90 observations of 23 systems in which one or more companions was detected, and six stars where no companion was detected to the limit of the camera capabilities at Gemini. In the case of the binary and multiple stars, these results are then further analyzed to make first orbit determinations in five cases, and orbit refinements in four other cases. The mass information is derived, and since the systems span a range in metallicity, a study is presented that compares our results with the expected trend in total mass as derived from the most recent Yale isochrones as a function of metal abundance. These data suggest that metal-poor main-sequence stars are less massive at a given color than their solar-metallicity analogues in a manner consistent with that predicted from the theory

  3. [Development of an Instrument to Assess the Quality of Childbirth Care from the Mother's Perspective].

    Science.gov (United States)

    Jeong, Geum Hee; Kim, Hyun Kyoung; Kim, Young Hee; Kim, Sun Hee; Lee, Sun Hee; Kim, Kyung Won

    2018-02-01

    This study aimed to develop an instrument to assess the quality of childbirth care from the perspective of a mother after delivery. The instrument was developed from a literature review, interviews, and item validation. Thirty-eight items were compiled for the instrument. The data for validity and reliability testing were collected using a questionnaire survey conducted on 270 women who had undergone normal vaginal delivery in Korea and analyzed with descriptive statistics, exploratory factor analysis, and reliability coefficients. The exploratory factor analysis reduced the number of items in the instrument to 28 items that were factored into four subscales: family-centered care, personal care, emotional empowerment, and information provision. With respect to convergence validation, there was positive correlation between this instrument and birth satisfaction scale (r=.34, pinstrument could be used as a measure of the quality of nursing care for women who have a normal vaginal delivery. © 2018 Korean Society of Nursing Science.

  4. Human reliability

    International Nuclear Information System (INIS)

    Embrey, D.E.

    1987-01-01

    Concepts and techniques of human reliability have been developed and are used mostly in probabilistic risk assessment. For this, the major application of human reliability assessment has been to identify the human errors which have a significant effect on the overall safety of the system and to quantify the probability of their occurrence. Some of the major issues within human reliability studies are reviewed and it is shown how these are applied to the assessment of human failures in systems. This is done under the following headings; models of human performance used in human reliability assessment, the nature of human error, classification of errors in man-machine systems, practical aspects, human reliability modelling in complex situations, quantification and examination of human reliability, judgement based approaches, holistic techniques and decision analytic approaches. (UK)

  5. Reliability Calculations

    DEFF Research Database (Denmark)

    Petersen, Kurt Erling

    1986-01-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety...... and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic...... approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very...

  6. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  7. Der Fragebogen "SFDP26-German": Ein verlässliches Instrument zur Evaluation des klinischen Unterrichts? [The Questionnaire "SFDP26-German": a reliable tool for evaluation of clinical teaching?

    Directory of Open Access Journals (Sweden)

    Iblher, Peter

    2011-05-01

    Full Text Available [english] Aims: Evaluation of the effectiveness of clinical teaching is an important contribution for the quality control of medical teaching. This should be evaluated using a reliable instrument in order to be able to both gauge the status quo and the effects of instruction. In the Stanford Faculty Development Program (SFDP, seven categories have proven to be appropriate: Since 1998, the SFDP26 questionnaire has established itself as an evaluation tool in English speaking countries. To date there is no equivalent German-language questionnaire available which evaluates the overall effectiveness of teaching.Question: Methods: 19 anaesthetists (7 female, 12 male from the University of Lübeck were evaluated at the end of a teaching seminar on emergency medical care using SFDP-German. The sample consisted of 173 medical students (119 female (68.8% and 54 male (31.2%, mostly from the fifth semester (6.6% and sixth semester (80.3%. The mean age of the students was 23±3 years. Results: The discriminatory power of all items ranged between good and excellent (r=0.48-0.75. All subscales displayed good internal consistency (α=0.69-0.92 and significant positive inter-scale correlations (r=0.40-0.70. The subscales and “overall effectiveness of teaching” showed significant correlation, with the highest correlation for the subscale “communication of goals (p< 0.001; r = 0.61.Conclusion: The analysis of SFDP26-German confirms high internal consistency. Future research should investigate the effectiveness of the individual categories on the overall effectiveness of teaching and validate according to external criteria. [german] Zielsetzung: Die Evaluation klinischer Lehrkompetenz ist ein wichtiger Beitrag zur Qualitätssicherung medizinischer Lehrveranstaltungen. Die Evaluation sollte mit einem verlässlichen Instrument durchgeführt werden, um Status quo sowie Effekte von medizindidaktischen Schulungsmaßnahmen beurteilen zu können. Im

  8. Health physics instrumentation needs

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Kenoyer, J.L.

    1984-10-01

    Deficiencies and desirable improvements can be identified in every technical area in which health physics instruments are employed. The needed improvements cover the full spectrum including long-term reliability, human factors, accuracy, ruggedness, ease of calibration, improved radiation response, and improved mixed field response. Some specific areas of deficiency noted along with needed improvements. 17 references

  9. Testing Standard Reliability Criteria

    Science.gov (United States)

    Sherry, David

    2017-01-01

    Maul's paper, "Rethinking Traditional Methods of Survey Validation" (Andrew Maul), contains two stages. First he presents empirical results that cast doubt on traditional methods for validating psychological measurement instruments. These results motivate the second stage, a critique of current conceptions of psychological measurement…

  10. Assessing quality of maternity care in Hungary: expert validation and testing of the mother-centered prenatal care (MCPC) survey instrument.

    Science.gov (United States)

    Rubashkin, Nicholas; Szebik, Imre; Baji, Petra; Szántó, Zsuzsa; Susánszky, Éva; Vedam, Saraswathi

    2017-11-16

    Instruments to assess quality of maternity care in Central and Eastern European (CEE) region are scarce, despite reports of poor doctor-patient communication, non-evidence-based care, and informal cash payments. We validated and tested an online questionnaire to study maternity care experiences among Hungarian women. Following literature review, we collated validated items and scales from two previous English-language surveys and adapted them to the Hungarian context. An expert panel assessed items for clarity and relevance on a 4-point ordinal scale. We calculated item-level Content Validation Index (CVI) scores. We designed 9 new items concerning informal cash payments, as well as 7 new "model of care" categories based on mode of payment. The final questionnaire (N = 111 items) was tested in two samples of Hungarian women, representative (N = 600) and convenience (N = 657). We conducted bivariate analysis and thematic analysis of open-ended responses. Experts rated pre-existing English-language items as clear and relevant to Hungarian women's maternity care experiences with an average CVI for included questions of 0.97. Significant differences emerged across the model of care categories in terms of informal payments, informed consent practices, and women's perceptions of autonomy. Thematic analysis (N = 1015) of women's responses identified 13 priority areas of the maternity care experience, 9 of which were addressed by the questionnaire. We developed and validated a comprehensive questionnaire that can be used to evaluate respectful maternity care, evidence-based practice, and informal cash payments in CEE region and beyond.

  11. Reliability Engineering

    CERN Document Server

    Lazzaroni, Massimo

    2012-01-01

    This book gives a practical guide for designers and users in Information and Communication Technology context. In particular, in the first Section, the definition of the fundamental terms according to the international standards are given. Then, some theoretical concepts and reliability models are presented in Chapters 2 and 3: the aim is to evaluate performance for components and systems and reliability growth. Chapter 4, by introducing the laboratory tests, puts in evidence the reliability concept from the experimental point of view. In ICT context, the failure rate for a given system can be

  12. Reliability training

    Science.gov (United States)

    Lalli, Vincent R. (Editor); Malec, Henry A. (Editor); Dillard, Richard B.; Wong, Kam L.; Barber, Frank J.; Barina, Frank J.

    1992-01-01

    Discussed here is failure physics, the study of how products, hardware, software, and systems fail and what can be done about it. The intent is to impart useful information, to extend the limits of production capability, and to assist in achieving low cost reliable products. A review of reliability for the years 1940 to 2000 is given. Next, a review of mathematics is given as well as a description of what elements contribute to product failures. Basic reliability theory and the disciplines that allow us to control and eliminate failures are elucidated.

  13. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  14. Instruments and Taxonomy of Workplace Bullying in Health Care Organizations

    Directory of Open Access Journals (Sweden)

    Eun-Jun Park, PhD, RN

    2017-12-01

    Full Text Available Summary: Purpose: This study was aimed to evaluate the methodological issues and comprehensiveness of workplace bullying instruments and to suggest a taxonomy of psychological abuse. Methods: Nineteen instruments applied in health care organizations and 469 questionnaire items mainly regarding psychological abuse were collected through a literature review. Three researchers classified the questionnaire items according to a “taxonomy of psychological abuse in the workplace.” Results: Many instruments of workplace bullying were developed in the 2000s using a reflective measurement model, but their psychometric property was not sufficient and the measurement model is questioned. Based on the questionnaire items, the “taxonomy of psychological abuse in the workplace” was modified by adding two new subcategories (unachievable work and unfair treatment and clarifying some operational definitions. According to the modified taxonomy of 11 (subcategories, the reviewed instruments assessed 6.5 (subcategories on average. No instrument measured all (subcategories. Category 4.2 (disrespect, humiliation, and rejection of the person was measured in all instruments, followed by Categories 5 (professional discredit and denigration and 1.2 (social isolation behaviors. Conclusion: The current instruments are not comprehensive enough. It is suggested that the modified taxonomy is verified and guide more reliable and inclusive instruments in the future. Furthermore, a formative measurement model, which defines a bullying as an inventory of different types of behaviors, should be used. Keywords: aggression, bullying, hostility, mobbing, surveys and questionnaires

  15. Nuclear instrumentation evaluation and analysis

    International Nuclear Information System (INIS)

    Park, Suk Jun; Han, Sang Joon; Chung, Chong Eun; Han, Kwang Soo; Kim, Dong Hwa; Park, Byung Hae; Moon, Je Sun; Lee, Chel Kwon; Song, Ki Sang; Choi, Myung Jin; Kim, Seung Bok; Kim, Jung Bok

    1986-12-01

    This project provides the program for improving instrumentation reliability as well as developing a cost-effective preventive maintenance activity through evaluation and analysis of nuclear instrumentation concerning pilot plants, large-scale test facilities and various laboratories on KAERI site. In addition, it discusses the program for enhancing safe operations and improving facility availability through establishment of maintenance technology. (Author)

  16. Reliability calculations

    International Nuclear Information System (INIS)

    Petersen, K.E.

    1986-03-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very complex systems. In order to increase the applicability of the programs variance reduction techniques can be applied to speed up the calculation process. Variance reduction techniques have been studied and procedures for implementation of importance sampling are suggested. (author)

  17. Surveying the impact of satisfaction and e-reliability on customers' loyalty in e-purchase process: a case in Pars Khodro co

    Directory of Open Access Journals (Sweden)

    Vahid Qaemi

    2012-10-01

    Full Text Available Today, customer return issue in e-purchase process is considered as important topic in companies' marketing and managerial decision making. In this paper, we present an empirical study on measuring the impact of e-loyalty for an Iranian auto-industry called Pars Khodro co. The proposed study measures reliability, responsiveness, design, security/privacy as independent variables, e-confidence and e-satisfaction as mediator variable, and e-loyalty as dependent variable. The preliminary results show that effectiveness of e-satisfaction and e-confidence on loyalty and effectiveness of e-confidence on e-satisfaction are in high level. Reliability/Fulfillment and security variables on e-confidence have significant impacts, and effectiveness level of reliability/Fulfillment and responsiveness and website design on e-satisfaction is high. The results indicate that there is no significant relationship between responsiveness and e-confidence.

  18. Validation of the National Institutes of Health Patient-Reported Outcomes Measurement Information System Survey as a Quality-of-Life Instrument for Patients with Malignant Brain Tumors and Their Caregivers.

    Science.gov (United States)

    Romero, Melissa M; Flood, Lisa Sue; Gasiewicz, Nanci K; Rovin, Richard; Conklin, Samantha

    2015-12-01

    At present there is a lack of well-validated surveys used to measure quality of life in patients with malignant brain tumors and their caregivers. The main objective of this pilot study was to validate the National Institutes of Health Patient-Reported Outcomes Measurement Information System (NIH PROMIS) survey for use as a quality-of-life measure in this population. This article presents the rationale for using the NIH PROMIS instrument as a quality-of-life measure for patients with malignant brain tumors and their caregivers. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Systems reliability/structural reliability

    International Nuclear Information System (INIS)

    Green, A.E.

    1980-01-01

    The question of reliability technology using quantified techniques is considered for systems and structures. Systems reliability analysis has progressed to a viable and proven methodology whereas this has yet to be fully achieved for large scale structures. Structural loading variants over the half-time of the plant are considered to be more difficult to analyse than for systems, even though a relatively crude model may be a necessary starting point. Various reliability characteristics and environmental conditions are considered which enter this problem. The rare event situation is briefly mentioned together with aspects of proof testing and normal and upset loading conditions. (orig.)

  20. How to Conduct Multimethod Field Studies in the Operating Room: The iPad Combined With a Survey App as a Valid and Reliable Data Collection Tool.

    Science.gov (United States)

    Tscholl, David W; Weiss, Mona; Spahn, Donat R; Noethiger, Christoph B

    2016-01-05

    Tablet computers such as the Apple iPad are progressively replacing traditional paper-and-pencil-based data collection. We combined the iPad with the ready-to-use survey software, iSurvey (from Harvestyourdata), to create a straightforward tool for data collection during the Anesthesia Pre-Induction Checklist (APIC) study, a hospital-wide multimethod intervention study involving observation of team performance and team member surveys in the operating room (OR). We aimed to provide an analysis of the factors that led to the use of the iPad- and iSurvey-based tool for data collection, illustrate our experiences with the use of this data collection tool, and report the results of an expert survey about user experience with this tool. We used an iPad- and iSurvey-based tool to observe anesthesia inductions conducted by 205 teams (N=557 team members) in the OR. In Phase 1, expert raters used the iPad- and iSurvey-based tool to rate team performance during anesthesia inductions, and anesthesia team members were asked to indicate their perceptions after the inductions. In Phase 2, we surveyed the expert raters about their perceptions regarding the use of the iPad- and iSurvey-based tool to observe, rate, and survey teams in the ORs. The results of Phase 1 showed that training data collectors on the iPad- and iSurvey-based data collection tool was effortless and there were no serious problems during data collection, upload, download, and export. Interrater agreement of the combined data collection tool was found to be very high for the team observations (median Fleiss' kappa=0.88, 95% CI 0.78-1.00). The results of the follow-up expert rater survey (Phase 2) showed that the raters did not prefer a paper-and-pencil-based data collection method they had used during other earlier studies over the iPad- and iSurvey-based tool (median response 1, IQR 1-1; 1=do not agree, 2=somewhat disagree, 3=neutral, 4=somewhat agree, 5=fully agree). They found the iPad (median 5, IQR 4

  1. Determinación de la confiabilidad del instrumento de efectividad familiar Determinação da confiabilidade do instrumento de efetividade familiar Determining the reliability of the family effectiveness instrument

    Directory of Open Access Journals (Sweden)

    Rosalba Leal Carrillo

    2011-07-01

    , mediante a aplicação do instrumento em 883 famílias da cidade de Villavicencio. A metodologia inclui um desenho de tipo descritivo com abordagem quantitativa, transversal. A confiabilidade foi valorada pelo método de fiabilidade de alfa de Cronbach com cada item. Entre os resultados verificouse que os coeficientes intra-individuais do instrumento estão entre 0,691 y 0,742; encontrouse consistência interna entre os itens. Na efetividade da funcionalidade familiar, a classificação das dimensões e metas das famílias em estudo foi de níveis baixo e médio com as seguintes porcentagens: dimensões de coerência, 46%; individuação, 47,5; manutenção, 29%; mudança no sistema, 52%. Metas de: crescimento, 49%, controle 52% e espiritualidade, 47%. Em conclusão, 49,3% das famílias foi classificada nos níveis baixo e intermédio de efetividade da funcionalidade familiar, o qual é coerente com o obtido nas dimensões e metas, e reflete uma incorporação de conhecimentos deficiente para adquirir novas condutas, problemas na comunicação efetiva, não divisão de experiências e sentimentos, dificuldade de adaptação a novos valores, estilos de vida, ausência de relações com outros sistemas familiares, deficiências em ações coletivas, dificuldade para incorporar novos conhecimentos e se apropriar de condutas para transformar a cultura (morfogênese; causando deterioro na evolução do sistema familiar.Astudy was carried out with the purpose of determining the reiability ofthe Spanish version ofthe Assessment Scale of Family Functionality Familiar, by Marie Luise Friedemann, and to identify the effectiveness of family functionality through the application ofthe instrument in 883 families in the city ofVillavicencio. Methodology included a descriptive design with quantitative approach, cross-cutting. Reliability was assessed through the alpha reliability method by Cronbach, with every item. Results show that the instrument's intra-individual coefficients are

  2. Disability as deprivation of capabilities: Estimation using a large-scale survey in Morocco and Tunisia and an instrumental variable approach.

    Science.gov (United States)

    Trani, Jean-Francois; Bakhshi, Parul; Brown, Derek; Lopez, Dominique; Gall, Fiona

    2018-05-25

    The capability approach pioneered by Amartya Sen and Martha Nussbaum offers a new paradigm to examine disability, poverty and their complex associations. Disability is hence defined as a situation in which a person with an impairment faces various forms of restrictions in functionings and capabilities. Additionally, poverty is not the mere absence of income but a lack of ability to achieve essential functionings; disability is consequently the poverty of capabilities of persons with impairment. It is the lack of opportunities in a given context and agency that leads to persons with disabilities being poorer than other social groups. Consequently, poverty of people with disabilities comprises of complex processes of social exclusion and disempowerment. Despite growing evidence that persons with disabilities face higher levels of poverty, the literature from low and middle-income countries that analyzes the causal link between disability and poverty, remains limited. Drawing on data from a large case control field survey carried out between December 24th , 2013 and February 16th , 2014 in Tunisia and between November 4th , 2013 and June 12th , 2014 in Morocco, we examined the effect of impairment on various basic capabilities, health related quality of life and multidimensional poverty - indicators of poor wellbeing-in Morocco and Tunisia. To demonstrate a causal link between impairment and deprivation of capabilities, we used instrumental variable regression analyses. In both countries, we found lower access to jobs for persons with impairment. Health related quality of life was also lower for this group who also faced a higher risk of multidimensional poverty. There was no significant direct effect of impairment on access to school and acquiring literacy in both countries, and on access to health care and expenses in Tunisia, while having an impairment reduced access to healthcare facilities in Morocco and out of pocket expenditures. These results suggest that

  3. Psychometric Evaluation of a New Instrument to Evaluate School Nurses' Perceptions on Concussion Care Management.

    Science.gov (United States)

    Schneider, Kathleen H

    2017-10-01

    The rate of concussions in adolescents has risen over the last decade, resulting in cognitive and emotional problems. Neurologists recommend cognitive and physical rest during the recovery period, followed by a transitional return-to-classroom protocol. The purpose of the study was to develop and test an instrument that explores the beliefs and roles of school nurses in concussion care management. The instrument was a cross-sectional descriptive survey based on the theory of planned behavior, using Qualtrics®. The psychometric properties of the instrument were assessed through exploratory factor analysis with orthogonal rotation. The reliability of the instrument was assessed for internal consistency reliability using Cronbach's α. Kaiser-Meyer-Olkin for sample adequacy was .8; Cronbach's α strong (.851).

  4. Multilevel Factor Structure, Concurrent Validity, and Test-Retest Reliability of the High School Teacher Version of the Authoritative School Climate Survey

    Science.gov (United States)

    Huang, Francis L.; Cornell, Dewey G.

    2016-01-01

    Although school climate has long been recognized as an important factor in the school improvement process, there are few psychometrically supported measures based on teacher perspectives. The current study replicated and extended the factor structure, concurrent validity, and test-retest reliability of the teacher version of the Authoritative…

  5. Traceability of radiation protection instruments

    Science.gov (United States)

    Hino, Y.; Kurosawa, T.

    2007-08-01

    Radiation protection instruments are used in daily measurement of dose and activities in workplaces and environments for safety management. The requirements for calibration certificates with traceability are increasing for these instruments to ensure the consistency and reliabilities of the measurement results. The present traceability scheme of radiation protection instruments for dose and activity measurements is described with related IEC/ISO requirements. Some examples of desirable future calibration systems with recent new technologies are also discussed to establish the traceability with reasonable costs and reliabilities.

  6. Reliability of Circumplex Axes

    Directory of Open Access Journals (Sweden)

    Micha Strack

    2013-06-01

    Full Text Available We present a confirmatory factor analysis (CFA procedure for computing the reliability of circumplex axes. The tau-equivalent CFA variance decomposition model estimates five variance components: general factor, axes, scale-specificity, block-specificity, and item-specificity. Only the axes variance component is used for reliability estimation. We apply the model to six circumplex types and 13 instruments assessing interpersonal and motivational constructs—Interpersonal Adjective List (IAL, Interpersonal Adjective Scales (revised; IAS-R, Inventory of Interpersonal Problems (IIP, Impact Messages Inventory (IMI, Circumplex Scales of Interpersonal Values (CSIV, Support Action Scale Circumplex (SAS-C, Interaction Problems With Animals (IPI-A, Team Role Circle (TRC, Competing Values Leadership Instrument (CV-LI, Love Styles, Organizational Culture Assessment Instrument (OCAI, Customer Orientation Circle (COC, and System for Multi-Level Observation of Groups (behavioral adjectives; SYMLOG—in 17 German-speaking samples (29 subsamples, grouped by self-report, other report, and metaperception assessments. The general factor accounted for a proportion ranging from 1% to 48% of the item variance, the axes component for 2% to 30%; and scale specificity for 1% to 28%, respectively. Reliability estimates varied considerably from .13 to .92. An application of the Nunnally and Bernstein formula proposed by Markey, Markey, and Tinsley overestimated axes reliabilities in cases of large-scale specificities but otherwise works effectively. Contemporary circumplex evaluations such as Tracey’s RANDALL are sensitive to the ratio of the axes and scale-specificity components. In contrast, the proposed model isolates both components.

  7. Instrumentation requirements for the ESF thermomechanical experiments

    International Nuclear Information System (INIS)

    Pott, J.; Brechtel, C.E.

    1992-01-01

    In situ thermomechanical experiments are planned as part of the Yucca Mountain Site Characterization Project that require instruments to measure stress and displacement at temperatures that exceed the typical specifications of existing geotechnical instruments. A high degree of instrument reliability will also be required to satisfy the objectives of the experiments, therefore a study was undertaken to identify areas where improvement in instrument performance was required. A preliminary list of instruments required for the experiments was developed, based on existing test planning and analysis. Projected temperature requirements were compared to specifications of existing instruments to identify instrumentation development needs. Different instrument technologies, not currently employed in geotechnical instrumentation, were reviewed to identify potential improvements of existing designs for the high temperature environment. Technologies with strong potentials to improve instrument performance with relatively high reliability include graphite fiber composite materials, fiber optics, and video imagery

  8. Human reliability

    International Nuclear Information System (INIS)

    Bubb, H.

    1992-01-01

    This book resulted from the activity of Task Force 4.2 - 'Human Reliability'. This group was established on February 27th, 1986, at the plenary meeting of the Technical Reliability Committee of VDI, within the framework of the joint committee of VDI on industrial systems technology - GIS. It is composed of representatives of industry, representatives of research institutes, of technical control boards and universities, whose job it is to study how man fits into the technical side of the world of work and to optimize this interaction. In a total of 17 sessions, information from the part of ergonomy dealing with human reliability in using technical systems at work was exchanged, and different methods for its evaluation were examined and analyzed. The outcome of this work was systematized and compiled in this book. (orig.) [de

  9. Microelectronics Reliability

    Science.gov (United States)

    2017-01-17

    inverters  connected in a chain. ................................................. 5  Figure 3  Typical graph showing frequency versus square root of...developing an experimental  reliability estimating methodology that could both illuminate the  lifetime  reliability of advanced devices,  circuits and...or  FIT of the device. In other words an accurate estimate of the device  lifetime  was found and thus the  reliability  that  can  be  conveniently

  10. Estimating the costs of consumer-facing cybercrime: A tailored instrument and representative data for six EU countries.

    NARCIS (Netherlands)

    Riek, Markus; Boehme, Rainer; Ciere, M.; Hernandez Ganan, C.; van Eeten, M.J.G.

    2016-01-01

    While cybercrime has existed for many years and is still reported to be a growing problem, reliable estimates of the economic impacts are rare. We develop a survey instrument tailored to measure the costs of consumer-facing cybercrime systematically, by aggregating different cost factors into direct

  11. Automated testing of health physics instruments

    International Nuclear Information System (INIS)

    Swinth, K.L.; Endres, A.W.; Hadley, R.T.; Kenoyer, J.L.

    1983-12-01

    A microcomputer controlled CAMAC system has been adapted for automated testing of health physics survey instruments. Once the survey instrument is positioned, the system automatically performs tests for angular dependence or battery lifetime. Rotation of the instrument is performed by a computer controlled stepping motor while readout is performed by an auto ranging digital volt meter and data stored on computer disks

  12. Instrumentation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Provides instrumentation support for flight tests of prototype weapons systems using a vast array of airborne sensors, transducers, signal conditioning and encoding...

  13. Reliability and validity of the Columbia Impairment Scale (C.I.S. for adolescents: Survey among an Italian sample in Lazio Region.

    Directory of Open Access Journals (Sweden)

    Alessandra Zanon

    2016-03-01

    Full Text Available Objective: Objective of this pilot study was to evaluate the reliability and internal consistency of the Columbia Impairment Scale questionnaire, as a tool to provide a global measure of impairment functioning in an Italian adolescents sample.Methods: The questionnaire is composed by 4 sections of functioning (interpersonal relations, broad psychopathological domains, functioning in schoolwork, use of leisure time for a total of 13 items. It was administered twice in the same sample belonging to a Professional School in Frosinone (Central Italy, to 120 adolescents on the first administration and to 108 on the second time. Reliability analysis was performed and Cronbach’s alpha was used as a measure of internal consistency. Statistical analysis was performed using SPSS 19.0.Results: Considering all 13 items, Cronbach’s alpha amounted to 0,762 on the first time and to 0.826 on the second time, showing a very satisfactory internal validity. In the sample selected, the answers to the questionnaire showed adolescents have a low impairment functioning.Conclusion: The results of the pilot study indicate that the questionnaire presents a good reliability property and in terms of internal consistency and validity shows a good performance. The results are promising and suggest that this tool cood be used in the Italian setting for future research targeted to adequately capture the impaired functioning in adolescents.

  14. Learning Style Scales: a valid and reliable questionnaire

    Directory of Open Access Journals (Sweden)

    Abdolghani Abdollahimohammad

    2014-08-01

    Full Text Available Purpose: Learning-style instruments assist students in developing their own learning strategies and outcomes, in eliminating learning barriers, and in acknowledging peer diversity. Only a few psychometrically validated learning-style instruments are available. This study aimed to develop a valid and reliable learning-style instrument for nursing students. Methods: A cross-sectional survey study was conducted in two nursing schools in two countries. A purposive sample of 156 undergraduate nursing students participated in the study. Face and content validity was obtained from an expert panel. The LSS construct was established using principal axis factoring (PAF with oblimin rotation, a scree plot test, and parallel analysis (PA. The reliability of LSS was tested using Cronbach’s α, corrected item-total correlation, and test-retest. Results: Factor analysis revealed five components, confirmed by PA and a relatively clear curve on the scree plot. Component strength and interpretability were also confirmed. The factors were labeled as perceptive, solitary, analytic, competitive, and imaginative learning styles. Cronbach’s α was > 0.70 for all subscales in both study populations. The corrected item-total correlations were > 0.30 for the items in each component. Conclusion: The LSS is a valid and reliable inventory for evaluating learning style preferences in nursing students in various multicultural environments.

  15. Learning Style Scales: a valid and reliable questionnaire.

    Science.gov (United States)

    Abdollahimohammad, Abdolghani; Ja'afar, Rogayah

    2014-01-01

    Learning-style instruments assist students in developing their own learning strategies and outcomes, in eliminating learning barriers, and in acknowledging peer diversity. Only a few psychometrically validated learning-style instruments are available. This study aimed to develop a valid and reliable learning-style instrument for nursing students. A cross-sectional survey study was conducted in two nursing schools in two countries. A purposive sample of 156 undergraduate nursing students participated in the study. Face and content validity was obtained from an expert panel. The LSS construct was established using principal axis factoring (PAF) with oblimin rotation, a scree plot test, and parallel analysis (PA). The reliability of LSS was tested using Cronbach's α, corrected item-total correlation, and test-retest. Factor analysis revealed five components, confirmed by PA and a relatively clear curve on the scree plot. Component strength and interpretability were also confirmed. The factors were labeled as perceptive, solitary, analytic, competitive, and imaginative learning styles. Cronbach's α was >0.70 for all subscales in both study populations. The corrected item-total correlations were >0.30 for the items in each component. The LSS is a valid and reliable inventory for evaluating learning style preferences in nursing students in various multicultural environments.

  16. Evaluating the Relational Coordination instrument

    DEFF Research Database (Denmark)

    Edwards, Kasper; Lundstrøm, Sanne Lykke

    2014-01-01

    consistency, interrater agreement and reliability, structural validity, content validity. However as relational coordination is being used as a diagnostics tool it is important to examine further if the instrument can measure changes. Indeed we need to know how precise and sensitive the instrument is when....... We distinguish between statistical and clinical significance. Statistical significance is calculated using T-test. Clinical significance is the minimal amount of change in relational coordination score that is not considered noise. Sensitivity of the instrument i.e. the ability of the instrument...

  17. Redefining reliability

    International Nuclear Information System (INIS)

    Paulson, S.L.

    1995-01-01

    Want to buy some reliability? The question would have been unthinkable in some markets served by the natural gas business even a few years ago, but in the new gas marketplace, industrial, commercial and even some residential customers have the opportunity to choose from among an array of options about the kind of natural gas service they need--and are willing to pay for. The complexities of this brave new world of restructuring and competition have sent the industry scrambling to find ways to educate and inform its customers about the increased responsibility they will have in determining the level of gas reliability they choose. This article discusses the new options and the new responsibilities of customers, the needed for continuous education, and MidAmerican Energy Company's experiment in direct marketing of natural gas

  18. Assessing the reliability of the short form 12 (SF-12) health survey in adults with mental health conditions: a report from the wellness incentive and navigation (WIN) study.

    Science.gov (United States)

    Huo, Tianyao; Guo, Yi; Shenkman, Elizabeth; Muller, Keith

    2018-02-13

    Although Short Form (SF)-12 × 2® has been extensively studied and used as a valid measure of health-related quality of life in a variety of population groups, no systematic studies have described the reliability of the measure in patients with behavioral conditions or serious mental illness (SMI). We assessed the internal consistency, split-half reliability and annual test-retest correlations in a sample of 1587 participants with either a combination of physical and behavioral conditions or SMI. The Mosier's alpha was 0.70 for the Physical Composite Scale (PCS) and 0.69 for the Mental Health Composite Scale (MCS), indicating good internal consistency. We observed strong correlations between physical functioning, physical role and body pain scales (r = 0.55-0.56), and between social functioning, emotional role, and mental health (r = 0.53-0.58). We calculated split-half reliabilities to be 0.74 for physical functioning, 0.75 for physical role, 0.73 for emotional role and 0.65 for mental health respectively. We assessed the annual test-retest correlation using intraclass correlation (ICC) and found an ICC of 0.61 for PCS and 0.57 for MCS composite scores, adjusting for age, sex, race/ethnicity, and CRG. We found no decline in the correlations between baseline and the following study years until year 3. Our results encourage using SF-12v2® to assess health-related quality of life in the Medicaid population with combined physical and behavioral conditions or similar cohorts. The WIN study was registered with clinicaltrials.gov on April 22, 2015. NCT02440906 . Retrospectively registered.

  19. Surveying the factor structure and reliability of the Persian version of the Jefferson Scale of Physician Lifelong Learning (JeffSPLL) in staff of medical sciences.

    Science.gov (United States)

    Karimi, Fatemeh Zahra; Alesheikh, Aytay; Pakravan, Soheila; Abdollahi, Mahbubeh; Damough, Mozhdeh; Anbaran, Zahra Khosravi; Farahani, Leila Amiri

    2017-10-01

    In medical sciences, commitment to lifelong learning has been expressed as an important element. Today, due to the rapid development of medical information and technology, lifelong learning is critical for safe medical care and development in medical research. JeffSPLL is one of the scales for measuring lifelong learning among the staff of medical sciences that has never been used in Iran. The aim of the present study was to determine the factor structure and reliability of the Persian version of JeffSPLL among Persian-speaking staff of universities of medical sciences in Iran. This study was a cross-sectional study, methodologically, that was conducted in 2012-2013. In this study, 210 staff members of Birjand University of Medical Sciences were selected. Data collection tool was the Persian version of JeffSPLL. To investigate the factor structure of this tool, confirmatory factor analysis was used and to evaluate the model fit, goodness-of-fit indices, root mean square error of approximation (RMSEA), the ratio of chi-square to the degree of freedom associated with it, comparative fit index (CFI), and root mean square residual (RMR) were used. To investigate the reliability of tool, Cronbach's alpha was employed. Data analysis was conducted using LISREL8.8 and SPSS 20 software. Confirmatory factor analysis showed that RMSEA was close to 0.1, and CFI and GFI were close to one. Therefore, four-factor model was appropriate. Cronbach's alpha was 0.92 for the whole tool and it was between 0.82 and 0.89 for subscales. The present study verified the four-factor structure of the 19-item Persian version of JeffSPLL that included professional learning beliefs and motivation, scholarly activities, attention to learning opportunities, and technical skills in information seeking among the staff. In addition, this tool has acceptable reliability. Therefore, it was appropriate to assess lifelong learning in the Persian-speaking staff population.

  20. Reliability and validity in a nutshell.

    Science.gov (United States)

    Bannigan, Katrina; Watson, Roger

    2009-12-01

    To explore and explain the different concepts of reliability and validity as they are related to measurement instruments in social science and health care. There are different concepts contained in the terms reliability and validity and these are often explained poorly and there is often confusion between them. To develop some clarity about reliability and validity a conceptual framework was built based on the existing literature. The concepts of reliability, validity and utility are explored and explained. Reliability contains the concepts of internal consistency and stability and equivalence. Validity contains the concepts of content, face, criterion, concurrent, predictive, construct, convergent (and divergent), factorial and discriminant. In addition, for clinical practice and research, it is essential to establish the utility of a measurement instrument. To use measurement instruments appropriately in clinical practice, the extent to which they are reliable, valid and usable must be established.

  1. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  2. Aerospace reliability applied to biomedicine.

    Science.gov (United States)

    Lalli, V. R.; Vargo, D. J.

    1972-01-01

    An analysis is presented that indicates that the reliability and quality assurance methodology selected by NASA to minimize failures in aerospace equipment can be applied directly to biomedical devices to improve hospital equipment reliability. The Space Electric Rocket Test project is used as an example of NASA application of reliability and quality assurance (R&QA) methods. By analogy a comparison is made to show how these same methods can be used in the development of transducers, instrumentation, and complex systems for use in medicine.

  3. [How Reliable is Neuronavigation?].

    Science.gov (United States)

    Stieglitz, Lennart Henning

    2016-02-17

    Neuronavigation plays a central role in modern neurosurgery. It allows visualizing instruments and three-dimensional image data intraoperatively and supports spatial orientation. Thus it allows to reduce surgical risks and speed up complex surgical procedures. The growing availability and importance of neuronavigation makes clear how relevant it is to know about its reliability and accuracy. Different factors may influence the accuracy during the surgery unnoticed, misleading the surgeon. Besides the best possible optimization of the systems themselves, a good knowledge about its weaknesses is mandatory for every neurosurgeon.

  4. A Survey of Florida High School Instrumental Music Programs: Rationale for the Inclusion of Jazz Ensemble Experience in Music Teacher Training

    Science.gov (United States)

    Hinkle, Jonathan R.

    2011-01-01

    During the past 60 years, jazz music has slowly become recognized as a genre worthy of study in high school music programs throughout the United States. Only a few researchers have analyzed large samples of jazz-related instruction in instrumental music programs, and of these studies no data were collected to investigate the inclusion of jazz in…

  5. Proof tests on reliability

    International Nuclear Information System (INIS)

    Mishima, Yoshitsugu

    1983-01-01

    In order to obtain public understanding on nuclear power plants, tests should be carried out to prove the reliability and safety of present LWR plants. For example, the aseismicity of nuclear power plants must be verified by using a large scale earthquake simulator. Reliability test began in fiscal 1975, and the proof tests on steam generators and on PWR support and flexure pins against stress corrosion cracking have already been completed, and the results have been internationally highly appreciated. The capacity factor of the nuclear power plant operation in Japan rose to 80% in the summer of 1983, and considering the period of regular inspection, it means the operation of almost full capacity. Japanese LWR technology has now risen to the top place in the world after having overcome the defects. The significance of the reliability test is to secure the functioning till the age limit is reached, to confirm the correct forecast of deteriorating process, to confirm the effectiveness of the remedy to defects and to confirm the accuracy of predicting the behavior of facilities. The reliability of nuclear valves, fuel assemblies, the heat affected zones in welding, reactor cooling pumps and electric instruments has been tested or is being tested. (Kako, I.)

  6. Validity of instruments to assess students' travel and pedestrian safety.

    Science.gov (United States)

    Mendoza, Jason A; Watson, Kathy; Baranowski, Tom; Nicklas, Theresa A; Uscanga, Doris K; Hanfling, Marcus J

    2010-05-18

    Safe Routes to School (SRTS) programs are designed to make walking and bicycling to school safe and accessible for children. Despite their growing popularity, few validated measures exist for assessing important outcomes such as type of student transport or pedestrian safety behaviors. This research validated the SRTS school travel survey and a pedestrian safety behavior checklist. Fourth grade students completed a brief written survey on how they got to school that day with set responses. Test-retest reliability was obtained 3-4 hours apart. Convergent validity of the SRTS travel survey was assessed by comparison to parents' report. For the measure of pedestrian safety behavior, 10 research assistants observed 29 students at a school intersection for completion of 8 selected pedestrian safety behaviors. Reliability was determined in two ways: correlations between the research assistants' ratings to that of the Principal Investigator (PI) and intraclass correlations (ICC) across research assistant ratings. The SRTS travel survey had high test-retest reliability (kappa = 0.97, n = 96, p < 0.001) and convergent validity (kappa = 0.87, n = 81, p < 0.001). The pedestrian safety behavior checklist had moderate reliability across research assistants' ratings (ICC = 0.48) and moderate correlation with the PI (r = 0.55, p = < 0.01). When two raters simultaneously used the instrument, the ICC increased to 0.65. Overall percent agreement (91%), sensitivity (85%) and specificity (83%) were acceptable. These validated instruments can be used to assess SRTS programs. The pedestrian safety behavior checklist may benefit from further formative work.

  7. Reliability of techniques used in the diagnosis of canine visceral leishmaniasis by the national control program in Brazil: A survey in an area of recent transmission.

    Science.gov (United States)

    Belo, Vinícius Silva; Gregório, Eliana Aparecida; Teixeira-Neto, Rafael Gonçalves; da Rocha Lima, Ana Cristina Vianna Mariano; Pereira, Agnes Antônia Sampaio; Marcelino, Andreza Pain; Paz, Gustavo Fontes; da Silva, Eduardo Sérgio

    2017-10-01

    One of the key components of the Brazilian Program for the Control of Visceral Leishmaniasis (PCLV) is the euthanasia of Leishmania-infected canine reservoirs, the detection of which depends on a screening procedure involving a Dual Path Platform ® (DPP) immunoassay and a confirmatory enzyme-linked immunosorbent assay (ELISA). The aims of the present study were to evaluate the reliability of these techniques in a region of recent transmission of canine VL, to follow up the seroconversion 3-4 months after the initial diagnosis of DPP reactive but ELISA indeterminate or non-reactive dogs, and to identify the species of Leishmania in circulation in the area. Each animal was submitted to DPP under field conditions, performed by municipal health workers using peripheral blood (DPP-field), to DPP under laboratory conditions using serum (DPP-lab) and to ELISA using serum. The agreements between the tests were determined using McNemar's χ 2 test, Cohen's kappa coefficient (k) at the 95% confidence interval and prevalence-adjusted bias-adjusted kappa (PABAK). Of the 1130 dogs examined, 74.2% were non-reactive in all three tests applied. Based on the PCLV positive-infection criterion, seroprevalence was 8.9% (101/1130) with 83.2% (84/101) of infected animals showing reactivity in all three tests while 7.8% (8/101) were reactive in DPP-field and ELISA and 8.9% (9/101) in DPP-lab and ELISA. The proportions of disagreements were substantial in all comparisons. Inter-rater reliability between DPP-field and ELISA (k=0.55; PABAK=0.78) and DPP-lab and ELISA (k=0.59; PABAK=0.81) were considered moderate, while that between DPP-field and DPP-lab (k=0.61; PABAK=0.79) was classified as marginally good. The proportion of seroconversions in DPP reactive animals that were initially ELISA indeterminate was significantly higher than in those that were DPP reactive but initially ELISA non-reactive. Restriction fragment length polymorphism analysis revealed the presence of Leishmania

  8. Translation, Assessment and Deployment of Stuttering Instruments into Different Languages: Comments Arising from Bakhtiar et al., "Investigation of the Reliability of the SSI-3 for Preschool Persian-Speaking Children Who Stutter" ["J. Fluency Disord." 35 (2010) 87-91

    Science.gov (United States)

    Karimi, Hamid; Nilipour, Reza; Shafiei, Bijan; Howell, Peter

    2011-01-01

    Bakhtiar, Seifpanahi, Ansari, Ghanadzade and Packman (2010) reported high inter-, and intra-judge agreement of a translation of the Stuttering Severity Instrument (SSI-3) for preschool Persian-speaking children who stutter. Translation of SSI-3 into Persian is desirable as there is no standardised stuttering severity test for that language.…

  9. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-15

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  10. Instrumental analysis

    International Nuclear Information System (INIS)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-01

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  11. LOFT instrumentation

    International Nuclear Information System (INIS)

    Bixby, W.W.

    1979-01-01

    A description of instrumentation used in the Loss-of-Fluid Test (LOFT) large break Loss-of-Coolant Experiments is presented. Emphasis is placed on hydraulic and thermal measurements in the primary system piping and components, reactor vessel, and pressure suppression system. In addition, instrumentation which is being considered for measurement of phenomena during future small break testing is discussed. (orig.) 891 HP/orig. 892 BRE [de

  12. Interfacing to accelerator instrumentation

    International Nuclear Information System (INIS)

    Shea, T.J.

    1995-01-01

    As the sensory system for an accelerator, the beam instrumentation provides a tremendous amount of diagnostic information. Access to this information can vary from periodic spot checks by operators to high bandwidth data acquisition during studies. In this paper, example applications will illustrate the requirements on interfaces between the control system and the instrumentation hardware. A survey of the major accelerator facilities will identify the most popular interface standards. The impact of developments such as isochronous protocols and embedded digital signal processing will also be discussed

  13. Validity of instruments to assess students' travel and pedestrian safety

    Directory of Open Access Journals (Sweden)

    Baranowski Tom

    2010-05-01

    Full Text Available Abstract Background Safe Routes to School (SRTS programs are designed to make walking and bicycling to school safe and accessible for children. Despite their growing popularity, few validated measures exist for assessing important outcomes such as type of student transport or pedestrian safety behaviors. This research validated the SRTS school travel survey and a pedestrian safety behavior checklist. Methods Fourth grade students completed a brief written survey on how they got to school that day with set responses. Test-retest reliability was obtained 3-4 hours apart. Convergent validity of the SRTS travel survey was assessed by comparison to parents' report. For the measure of pedestrian safety behavior, 10 research assistants observed 29 students at a school intersection for completion of 8 selected pedestrian safety behaviors. Reliability was determined in two ways: correlations between the research assistants' ratings to that of the Principal Investigator (PI and intraclass correlations (ICC across research assistant ratings. Results The SRTS travel survey had high test-retest reliability (κ = 0.97, n = 96, p Conclusions These validated instruments can be used to assess SRTS programs. The pedestrian safety behavior checklist may benefit from further formative work.

  14. Can health workers reliably assess their own work? A test-retest study of bias among data collectors conducting a Lot Quality Assurance Sampling survey in Uganda.

    Science.gov (United States)

    Beckworth, Colin A; Davis, Rosemary H; Faragher, Brian; Valadez, Joseph J

    2015-03-01

    Lot Quality Assurance Sampling (LQAS) is a classification method that enables local health staff to assess health programmes for which they are responsible. While LQAS has been favourably reviewed by the World Bank and World Health Organization (WHO), questions remain about whether using local health staff as data collectors can lead to biased data. In this test-retest research, Pallisa Health District in Uganda is subdivided into four administrative units called supervision areas (SA). Data collectors from each SA conducted an LQAS survey. A week later, the data collectors were swapped to a different SA, outside their area of responsibility, to repeat the LQAS survey with the same respondents. The two data sets were analysed for agreement using Cohens' kappa coefficient and disagreements were analysed. Kappa values ranged from 0.19 to 0.97. On average, there was a moderate degree of agreement for knowledge indicators and a substantial level for practice indicators. Respondents were found to be systematically more knowledgeable on retest indicating bias favouring the retest, although no evidence of bias was found for practices indicators. In this initial study, using local health care providers to collect data did not bias data collection. The bias observed in the knowledge indicators is most likely due to the 'practice effect', whereby respondents increased their knowledge as a result of completing the first survey, as no corresponding effect was seen in the practices indicators. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2014; all rights reserved.

  15. Reliability and Validity of a Survey of Cat Caregivers on Their Cats’ Socialization Level in the Cat’s Normal Environment

    OpenAIRE

    Slater, Margaret; Garrison, Laurie; Miller, Katherine; Weiss, Emily; Makolinski, Kathleen; Drain, Natasha

    2013-01-01

    Simple Summary Many animal welfare organizations accept cats with no known behavioral history. It can be difficult to differentiate between a frightened but well-socialized cat and an unsocialized cat in an animal shelter environment. Making this distinction can save lives, yet currently there is no valid tool. Here we measured the quality of a survey designed to determine socialization level using information from the cat’s caregiver about a cat’s usual behavior around people in the cat’s no...

  16. Measuring stakeholder participation in evaluation: an empirical validation of the Participatory Evaluation Measurement Instrument (PEMI).

    Science.gov (United States)

    Daigneault, Pierre-Marc; Jacob, Steve; Tremblay, Joël

    2012-08-01

    Stakeholder participation is an important trend in the field of program evaluation. Although a few measurement instruments have been proposed, they either have not been empirically validated or do not cover the full content of the concept. This study consists of a first empirical validation of a measurement instrument that fully covers the content of participation, namely the Participatory Evaluation Measurement Instrument (PEMI). It specifically examines (1) the intercoder reliability of scores derived by two research assistants on published evaluation cases; (2) the convergence between the scores of coders and those of key respondents (i.e., authors); and (3) the convergence between the authors' scores on the PEMI and the Evaluation Involvement Scale (EIS). A purposive sample of 40 cases drawn from the evaluation literature was used to assess reliability. One author per case in this sample was then invited to participate in a survey; 25 fully usable questionnaires were received. Stakeholder participation was measured on nominal and ordinal scales. Cohen's κ, the intraclass correlation coefficient, and Spearman's ρ were used to assess reliability and convergence. Reliability results ranged from fair to excellent. Convergence between coders' and authors' scores ranged from poor to good. Scores derived from the PEMI and the EIS were moderately associated. Evidence from this study is strong in the case of intercoder reliability and ranges from weak to strong in the case of convergent validation. Globally, this suggests that the PEMI can produce scores that are both reliable and valid.

  17. Considerations in comparing the U.S. Geological Survey one‐year induced‐seismicity hazard models with “Did You Feel It?” and instrumental data

    Science.gov (United States)

    White, Isabel; Liu, Taojun; Luco, Nicolas; Liel, Abbie

    2017-01-01

    The recent steep increase in seismicity rates in Oklahoma, southern Kansas, and other parts of the central United States led the U.S. Geological Survey (USGS) to develop, for the first time, a probabilistic seismic hazard forecast for one year (2016) that incorporates induced seismicity. In this study, we explore a process to ground‐truth the hazard model by comparing it with two databases of observations: modified Mercalli intensity (MMI) data from the “Did You Feel It?” (DYFI) system and peak ground acceleration (PGA) values from instrumental data. Because the 2016 hazard model was heavily based on earthquake catalogs from 2014 to 2015, this initial comparison utilized observations from these years. Annualized exceedance rates were calculated with the DYFI and instrumental data for direct comparison with the model. These comparisons required assessment of the options for converting hazard model results and instrumental data from PGA to MMI for comparison with the DYFI data. In addition, to account for known differences that affect the comparisons, the instrumental PGA and DYFI data were declustered, and the hazard model was adjusted for local site conditions. With these adjustments, examples at sites with the most data show reasonable agreement in the exceedance rates. However, the comparisons were complicated by the spatial and temporal completeness of the instrumental and DYFI observations. Furthermore, most of the DYFI responses are in the MMI II–IV range, whereas the hazard model is oriented toward forecasts at higher ground‐motion intensities, usually above about MMI IV. Nevertheless, the study demonstrates some of the issues that arise in making these comparisons, thereby informing future efforts to ground‐truth and improve hazard modeling for induced‐seismicity applications.

  18. Microprocessor hardware reliability

    Energy Technology Data Exchange (ETDEWEB)

    Wright, R I

    1982-01-01

    Microprocessor-based technology has had an impact in nearly every area of industrial electronics and many applications have important safety implications. Microprocessors are being used for the monitoring and control of hazardous processes in the chemical, oil and power generation industries, for the control and instrumentation of aircraft and other transport systems and for the control of industrial machinery. Even in the field of nuclear reactor protection, where designers are particularly conservative, microprocessors are used to implement certain safety functions and may play increasingly important roles in protection systems in the future. Where microprocessors are simply replacing conventional hard-wired control and instrumentation systems no new hazards are created by their use. In the field of robotics, however, the microprocessor has opened up a totally new technology and with it has created possible new and as yet unknown hazards. The paper discusses some of the design and manufacturing techniques which may be used to enhance the reliability of microprocessor based systems and examines the available reliability data on lsi/vlsi microcircuits. 12 references.

  19. A Practitioner's Instrument for Measuring Secondary Mathematics Teachers' Beliefs Surrounding Learner-Centered Classroom Practice.

    Science.gov (United States)

    Lischka, Alyson E; Garner, Mary

    In this paper we present the development and validation of a Mathematics Teaching Pedagogical and Discourse Beliefs Instrument (MTPDBI), a 20 item partial-credit survey designed and analyzed using Rasch measurement theory. Items on the MTPDBI address beliefs about the nature of mathematics, teaching and learning mathematics, and classroom discourse practices. A Rasch partial credit model (Masters, 1982) was estimated from the pilot study data. Results show that item separation reliability is .96 and person separation reliability is .71. Other analyses indicate the instrument is a viable measure of secondary teachers' beliefs about reform-oriented mathematics teaching and learning. This instrument is proposed as a useful measure of teacher beliefs for those working with pre-service and in-service teacher development.

  20. IAEA safeguards instrumentation: Development, implementation and control

    International Nuclear Information System (INIS)

    Rundquist, D.E.

    1983-01-01

    Extensive development efforts over the last 5 years have produced a number of new instruments to help the IAEA meet its safeguards obligations. Implementation of these new instruments is proceeding at a necessarily slower pace. To optimize the performance and reliability of the instrumentation systems when used in safeguards applications, increasing attention is needed to be spent on performance monitoring and control of the instruments. (author)

  1. A Categorical Instrument for Scoring Second Language Writing Skills.

    Science.gov (United States)

    Brown, James Dean; Bailey, Kathleen M.

    1984-01-01

    Discusses a study of the reliability of a categorical instrument for evaluating compositions written by upper intermediate university English as a second language students. The instrument tests organization, logical development of ideas, grammar, mechanics, and style. Results indicate that the scoring instrument is moderately reliable. (SED)

  2. Maps and plans reliability in tourism activities

    Directory of Open Access Journals (Sweden)

    Олександр Донцов

    2016-10-01

    Full Text Available The paper is devoted to creation of an effective system of mapping at all levels of tourist-excursion functioning that will boost the promotion of tourist product in a domestic and foreign tourist market. The State Scientific - Production Enterprise «Kartographia» actively participates in cartographic tourism provision by producing travel pieces, survey, large-scale, route maps, atlases, travel guides, city plans. They produce maps covering different content of the territory of Ukraine, its individual regions, cities interested in tourist excursions. The list and scope of cartographic products has been prepared for publication and released for the last five years. The development of new types of tourism encourages publishers to create various cartographic products for the needs of tourists guaranteeing high accuracy, reliability of information, ease of use. A variety of scientific and practical problems in tourism and excursion activities that are solved using maps and plans makes it difficult to determine the criteria for assessing their reliability. The author proposes to introduce the concept of «relevance» - as maps suitability to solving specific problems. The basis of the peer review is suitability of maps for the objective results release criteria: appropriateness of the target maps tasks (area, theme, destination; accuracy of given parameters (projection, scale, height interval; year according to the shooting of location or mapping; selection methods, methods of results measurement processing algorithm; availability of assistive devices (instrumentation, computer technology, simulation devices. These criteria provide the reliability and accuracy of the result as acceptable to consumers as possible. The author proposes a set of measures aimed at improving the content, quality and reliability of cartographic production.

  3. NURE aerial gamma-ray and magnetic-reconnaissance survey portions of New Mexico, Arizona, and Texas. Volume I. Instrumentation and data reduction. Final report

    International Nuclear Information System (INIS)

    1981-09-01

    As part of the Department of Energy (DOE) National Uranium Resource Evaluation Program, a rotary-wing high sensitivity radiometric and magnetic survey was flown covering portions of the State of New Mexico, Arizona and Texas. The survey encompassed six 1:250,000 scale quadrangles, Holbrook, El Paso, Las Cruces, Carlsbad, Fort Sumner and Roswell. The survey was flown with a Sikorsky S58T helicopter equipped with a high sensitivity gamma ray spectrometer which was calibrated at the DOE calibration facilities at Walker Field in Grand Junction, Colorado, and the Dynamic Test Range at Lake Mead, Arizona. The radiometric data were processed to compensate for Compton scattering effects and altitude variations. The data were normalized to 400 feet terrain clearance. The reduced data is presented in the form of stacked profiles, standard deviation anomaly plots, histogram plots and microfiche listings. The results of the geologic interpretation of the radiometric data together with the profiles, anomaly maps and histograms are presented in the individual quadrangle reports. The survey was awarded to LKB Resources, Inc. which completed the data acquisition. In April, 1980 Carson Helicopters, Inc. and Carson Geoscience Company agreed to manage the project and complete delivery of this final report

  4. NURE aerial gamma-ray and magnetic-reconnaissance survey portions of New Mexico, Arizona, and Texas. Volume I. Instrumentation and data reduction. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1981-09-01

    As part of the Department of Energy (DOE) National Uranium Resource Evaluation Program, a rotary-wing high sensitivity radiometric and magnetic survey was flown covering portions of the State of New Mexico, Arizona and Texas. The survey encompassed six 1:250,000 scale quadrangles, Holbrook, El Paso, Las Cruces, Carlsbad, Fort Sumner and Roswell. The survey was flown with a Sikorsky S58T helicopter equipped with a high sensitivity gamma ray spectrometer which was calibrated at the DOE calibration facilities at Walker Field in Grand Junction, Colorado, and the Dynamic Test Range at Lake Mead, Arizona. The radiometric data were processed to compensate for Compton scattering effects and altitude variations. The data were normalized to 400 feet terrain clearance. The reduced data is presented in the form of stacked profiles, standard deviation anomaly plots, histogram plots and microfiche listings. The results of the geologic interpretation of the radiometric data together with the profiles, anomaly maps and histograms are presented in the individual quadrangle reports. The survey was awarded to LKB Resources, Inc. which completed the data acquisition. In April, 1980 Carson Helicopters, Inc. and Carson Geoscience Company agreed to manage the project and complete delivery of this final report.

  5. Instrumental Capital

    Directory of Open Access Journals (Sweden)

    Gabriel Valerio

    2007-07-01

    Full Text Available During the history of human kind, since our first ancestors, tools have represented a mean to reach objectives which might otherwise seemed impossibles. In the called New Economy, where tangibles assets appear to be losing the role as the core element to produce value versus knowledge, tools have kept aside man in his dairy work. In this article, the author's objective is to describe, in a simple manner, the importance of managing the organization's group of tools or instruments (Instrumental Capital. The characteristic conditions of this New Economy, the way Knowledge Management deals with these new conditions and the sub-processes that provide support to the management of Instrumental Capital are described.

  6. A practical guide to surveys and questionnaires.

    Science.gov (United States)

    Slattery, Eric L; Voelker, Courtney C J; Nussenbaum, Brian; Rich, Jason T; Paniello, Randal C; Neely, J Gail

    2011-06-01

    Surveys with questionnaires play a vital role in decision and policy making in society. Within medicine, including otolaryngology, surveys with questionnaires may be the only method for gathering data on rare or unusual events. In addition, questionnaires can be developed and validated to be used as outcome measures in clinical trials and other clinical research architecture. Consequently, it is fundamentally important that such tools be properly developed and validated. Just asking questions that have not gone through rigorous design and development may be misleading and unfair at best; at worst, they can result in under- or overtreatment and unnecessary expense. Furthermore, it is important that consumers of the data produced by these instruments understand the principles of questionnaire design to interpret results in an optimal and meaningful way. This article presents a practical guide for understanding the methodologies of survey and questionnaire design, including the concepts of validity and reliability, how surveys are administered and implemented, and, finally, biases and pitfalls of surveys.

  7. Conceptual Software Reliability Prediction Models for Nuclear Power Plant Safety Systems

    International Nuclear Information System (INIS)

    Johnson, G.; Lawrence, D.; Yu, H.

    2000-01-01

    The objective of this project is to develop a method to predict the potential reliability of software to be used in a digital system instrumentation and control system. The reliability prediction is to make use of existing measures of software reliability such as those described in IEEE Std 982 and 982.2. This prediction must be of sufficient accuracy to provide a value for uncertainty that could be used in a nuclear power plant probabilistic risk assessment (PRA). For the purposes of the project, reliability was defined to be the probability that the digital system will successfully perform its intended safety function (for the distribution of conditions under which it is expected to respond) upon demand with no unintended functions that might affect system safety. The ultimate objective is to use the identified measures to develop a method for predicting the potential quantitative reliability of a digital system. The reliability prediction models proposed in this report are conceptual in nature. That is, possible prediction techniques are proposed and trial models are built, but in order to become a useful tool for predicting reliability, the models must be tested, modified according to the results, and validated. Using methods outlined by this project, models could be constructed to develop reliability estimates for elements of software systems. This would require careful review and refinement of the models, development of model parameters from actual experience data or expert elicitation, and careful validation. By combining these reliability estimates (generated from the validated models for the constituent parts) in structural software models, the reliability of the software system could then be predicted. Modeling digital system reliability will also require that methods be developed for combining reliability estimates for hardware and software. System structural models must also be developed in order to predict system reliability based upon the reliability

  8. An Introduction To Reliability

    International Nuclear Information System (INIS)

    Park, Kyoung Su

    1993-08-01

    This book introduces reliability with definition of reliability, requirement of reliability, system of life cycle and reliability, reliability and failure rate such as summary, reliability characteristic, chance failure, failure rate which changes over time, failure mode, replacement, reliability in engineering design, reliability test over assumption of failure rate, and drawing of reliability data, prediction of system reliability, conservation of system, failure such as summary and failure relay and analysis of system safety.

  9. Innovative instrumentation

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all

  10. Innovative instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1983-11-15

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all.

  11. Instrumental aspects

    Directory of Open Access Journals (Sweden)

    Qureshi Navid

    2017-01-01

    Full Text Available Every neutron scattering experiment requires the choice of a suited neutron diffractometer (or spectrometer in the case of inelastic scattering with its optimal configuration in order to accomplish the experimental tasks in the most successful way. Most generally, the compromise between the incident neutron flux and the instrumental resolution has to be considered, which is depending on a number of optical devices which are positioned in the neutron beam path. In this chapter the basic instrumental principles of neutron diffraction will be explained. Examples of different types of experiments and their respective expectable results will be shown. Furthermore, the production and use of polarized neutrons will be stressed.

  12. TWO CRITERIA FOR GOOD MEASUREMENTS IN RESEARCH: VALIDITY AND RELIABILITY

    Directory of Open Access Journals (Sweden)

    Haradhan Kumar Mohajan

    2017-12-01

    Full Text Available Reliability and validity are two most important and fundamental features in the evaluation of any measurement instrument or toll for a good research. The purpose of this research is to discuss the validity and reliability of measurement instruments that are used in research. Validity concerns what an instrument measures, and how well it does so. Reliability concerns the faith that one can have in the data obtained from use of an instrument, that is, the degree to which any measuring tool controls for random error. An attempt has been taken here to review the reliability and validity, and threat to them in some details.

  13. Validation of the Care-Related Quality of Life Instrument in different study settings: findings from The Older Persons and Informal Caregivers Survey Minimum DataSet (TOPICS-MDS).

    Science.gov (United States)

    Lutomski, J E; van Exel, N J A; Kempen, G I J M; Moll van Charante, E P; den Elzen, W P J; Jansen, A P D; Krabbe, P F M; Steunenberg, B; Steyerberg, E W; Olde Rikkert, M G M; Melis, R J F

    2015-05-01

    Validity is a contextual aspect of a scale which may differ across sample populations and study protocols. The objective of our study was to validate the Care-Related Quality of Life Instrument (CarerQol) across two different study design features, sampling framework (general population vs. different care settings) and survey mode (interview vs. written questionnaire). Data were extracted from The Older Persons and Informal Caregivers Minimum DataSet (TOPICS-MDS, www.topics-mds.eu ), a pooled public-access data set with information on >3,000 informal caregivers throughout the Netherlands. Meta-correlations and linear mixed models between the CarerQol's seven dimensions (CarerQol-7D) and caregiver's level of happiness (CarerQol-VAS) and self-rated burden (SRB) were performed. The CarerQol-7D dimensions were correlated to the CarerQol-VAS and SRB in the pooled data set and the subgroups. The strength of correlations between CarerQol-7D dimensions and SRB was weaker among caregivers who were interviewed versus those who completed a written questionnaire. The directionality of associations between the CarerQol-VAS, SRB and the CarerQol-7D dimensions in the multivariate model supported the construct validity of the CarerQol in the pooled population. Significant interaction terms were observed in several dimensions of the CarerQol-7D across sampling frame and survey mode, suggesting meaningful differences in reporting levels. Although good scientific practice emphasises the importance of re-evaluating instrument properties in individual research studies, our findings support the validity and applicability of the CarerQol instrument in a variety of settings. Due to minor differential reporting, pooling CarerQol data collected using mixed administration modes should be interpreted with caution; for TOPICS-MDS, meta-analytic techniques may be warranted.

  14. Reliability of the Arabic Smartphone Addiction Scale and Smartphone Addiction Scale-Short Version in Two Different Moroccan Samples.

    Science.gov (United States)

    Sfendla, Anis; Laita, Meriame; Nejjar, Basma; Souirti, Zouhayr; Touhami, Ahami Ahmed Omar; Senhaji, Meftaha

    2018-05-01

    The extensive accessibility to smartphones in the last decade raises the concerns of addictive behavior patterns toward these technologies worldwide and in developing countries, and Arabic ones in particular. In an area of stigmatized behavior such as Internet and smartphone addiction, the hypothesis extends to whether there is a reliable instrument that can assess smartphone addiction. To our knowledge, no scale in Arabic language is available to assess maladaptive behavior associated with smartphone use. This study aims to assess the factorial validity and internal reliability of the Arabic Smartphone Addiction Scale (SAS) and Smartphone Addiction Scale-Short Version (SAS-SV) in a Moroccan surveyed population. Participants (N = 440 and N = 310) completed an online survey, including SAS, SAS-SV, and questions about sociodemographic status. Factor analysis results showed six factors with factor loading ranging from 0.25 to 0.99 for SAS. Reliability, based on Cronbach's alpha, was excellent (α = 0.94) for this instrument. The SAS-SV showed one factor (unidimensional construct), and internal reliability was in the good range with an alpha coefficient of (α = 0.87). The prevalence of excessive users was 55.8 percent with highest symptom prevalence reported for tolerance and preoccupation. This study proved factor validity of the Arabic SAS and SAS-SV instruments and confirmed their internal reliability.

  15. Study on team evaluation (4). Reliability and validity of questionnaire survey-based team work evaluation method of power plant operator team

    International Nuclear Information System (INIS)

    Sasou, Kunihide; Hirose, Ayako; Misawa, Ryou; Yamaguchi, Hiroyuki

    2006-01-01

    The series of this study describes the necessity of the evaluation of team work from two aspects of operator's behavior and operators' mind. The authors propose Team Work Element Model which consists of necessary elements to build high performance team. This report discusses a method to evaluate team work from the second aspect, that is, competency trust, competition, for-the team spirit, etc. The authors survey the previous studies on psychological measures and organize a set of questions to evaluate 10 team work sub elements that are the parts of Team Work Element Model. The factor analysis shows that this set of questions is consists of 13 factors such as task-oriented leadership, harmony-oriented team atmosphere, etc. Close examination of the questions in each factor shows that 8 of 10 team work sub elements can be evaluated by this questionnaire. In addition, this questionnaire comprises scales additional 8 scales such as job satisfaction, leadership, etc. As a result, it is possible to evaluate team work from more comprehensive view points. (author)

  16. Surgical Instrument

    NARCIS (Netherlands)

    Dankelman, J.; Horeman, T.

    2009-01-01

    The present invention relates to a surgical instrument for minimall-invasive surgery, comprising a handle, a shaft and an actuating part, characterised by a gastight cover surrounding the shaft, wherein the cover is provided with a coupler that has a feed- through opening with a loskable seal,

  17. Weather Instruments.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities to measure various weather phenomena. Directions for constructing a weather station are included. Instruments including rain gauges, thermometers, wind vanes, wind speed devices, humidity devices, barometers, atmospheric observations, a dustfall jar, sticky-tape can, detection of gases in the air, and pH of…

  18. Scale Reliability Evaluation with Heterogeneous Populations

    Science.gov (United States)

    Raykov, Tenko; Marcoulides, George A.

    2015-01-01

    A latent variable modeling approach for scale reliability evaluation in heterogeneous populations is discussed. The method can be used for point and interval estimation of reliability of multicomponent measuring instruments in populations representing mixtures of an unknown number of latent classes or subpopulations. The procedure is helpful also…

  19. The short form of the fear survey schedule for children-revised (FSSC-R-SF): an efficient, reliable, and valid scale for measuring fear in children and adolescents.

    Science.gov (United States)

    Muris, Peter; Ollendick, Thomas H; Roelofs, Jeffrey; Austin, Kristin

    2014-12-01

    The present study examined the psychometric properties of the Short Form of the Fear Survey Schedule for Children-Revised (FSSC-R-SF) in non-clinical and clinically referred children and adolescents from the Netherlands and the United States. Exploratory as well as confirmatory factor analyses of the FSSC-R-SF yielded support for the hypothesized five-factor structure representing fears in the domains of (1) failure and criticism, (2) the unknown, (3) animals, (4) danger and death, and (5) medical affairs. The FSSC-R-SF showed satisfactory reliability and was capable of assessing gender and age differences in youths' fears and fearfulness that have been documented in previous research. Further, the convergent validity of the scale was good as shown by substantial and meaningful correlations with the full-length FSSC-R and alternative childhood anxiety measures. Finally, support was found for the discriminant validity of the scale. That is, clinically referred children and adolescents exhibited higher scores on the FSSC-R-SF total scale and most subscales as compared to their non-clinical counterparts. Moreover, within the clinical sample, children and adolescents with a major anxiety disorder generally displayed higher FSSC-R-SF scores than youths without such a diagnosis. Altogether, these findings indicate that the FSSC-R-SF is a brief, reliable, and valid scale for assessing fear sensitivities in children and adolescents. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Designing an Instrument to Measure the QoS of a Spanish Virtual Store

    Science.gov (United States)

    de Abajo, Beatriz Sainz; de La Torre Díez, Isabel; Salcines, Enrique García; Fernández, Javier Burón; Pernas, Francisco Díaz; Coronado, Miguel López; de Castro Lozano, Carlos

    This article describes the development of an instrument, in the form of a survey, which is distributed to users of a B2C website selling electronic books in order to ascertain their satisfaction. The opinions compiled from a pilot sample and the exploratory factor analysis carried out point to factors that best summarise the quality of the application analysed here. Analysis of the initial survey, with a total of 40 items, shaped the final instrument, encompassing 18 items divided into 6 dimensions, which measure the perceptions of users of the application in order to improve the contents of the website. Subsequently, a confirmatory factorial analysis is performed, ensuring the reliability of the study and which confirms that the structure of the instrument developed truly measures service quality in accordance with the requirements of the website in terms of offering a space that fulfils consumer expectations in the Information Society.

  1. How discriminating are discriminative instruments?

    Science.gov (United States)

    Hankins, Matthew

    2008-05-27

    The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL). The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness), but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta) is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.

  2. How discriminating are discriminative instruments?

    Directory of Open Access Journals (Sweden)

    Hankins Matthew

    2008-05-01

    Full Text Available Abstract The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL. The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness, but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.

  3. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  4. Global impression of perceived difficulties in children and adolescents with attention-deficit/hyperactivity disorder: Reliability and validity of a new instrument assessing perceived difficulties from a patient, parent and physician perspective over the day

    Directory of Open Access Journals (Sweden)

    Dittmann Ralf W

    2008-05-01

    Full Text Available Abstract Background The objective of this analysis was to evaluate the psychometric properties of a brief scale developed to assess the degree of difficulties in children with Attention-Deficit/Hyperactivity Disorder (ADHD. The Global Impression of Perceived Difficulties (GIPD scale reflects overall impairment, psychosocial functioning and Quality of Life (QoL as rated by patient, parents and physician at various times of the day. Methods In two open-label studies, ADHD-patients aged 6–17 years were treated with atomoxetine (target-dose 0.5–1.2 mg/kg/day. ADHD-related difficulties were assessed up to week 24 using the GIPD. Data from both studies were combined to validate the scale. Results Overall, 421 patients received atomoxetine. GIPD scores improved over time. All three GIPD-versions (patient, parent, physician were internally consistent; all items showed at least moderate item-total correlation. The scale showed good test-retest reliability over a two-week period from all three perspectives. Good convergent and discriminant validity was shown. Conclusion GIPD is an internally consistent, reliable and valid measure to assess difficulties in children with ADHD at various times of the day and can be used as indicator for psychosocial impairment and QoL. The scale is sensitive to treatment-related change.

  5. Instrumental analysis, second edition

    International Nuclear Information System (INIS)

    Christian, G.D.; O'Reilly, J.E.

    1988-01-01

    The second edition of Instrumental Analysis is a survey of the major instrument-based methods of chemical analysis. It appears to be aimed at undergraduates but would be equally useful in a graduate course. The volume explores all of the classical quantitative methods and contains sections on techniques that usually are not included in a semester course in instrumentation (such as electron spectroscopy and the kinetic methods). Adequate coverage of all of the methods contained in this book would require several semesters of focused study. The 25 chapters were written by different authors, yet the style throughout the book is more uniform than in the earlier edition. With the exception of a two-chapter course in analog and digital circuits, the book purports to de-emphasize instrumentation, focusing more on the theory behind the methods and the application of the methods to analytical problems. However, a detailed analysis of the instruments used in each method is by no means absent. The book has the favor of a user's guide to analysis

  6. Smart antennas for nuclear instruments

    International Nuclear Information System (INIS)

    Jain, Ranjan Bala; Singhi, B.M.

    2005-01-01

    The advances in the field of computer and communications are leading to the development of smart embedded nuclear instruments. These instruments have highly sophisticated signal-processing algorithms based on FPGA and ASICS, provisions of present day connectivity and user interfaces. The developments in the connectivity, standards and bus technologies have made possible to access these instruments on LAN and WAN with suitable reliability and security. To get rid of wires i.e. in order to access these instruments, without wires at any place, wireless technology has evolved and become integral part of day-to-day activities. The environment monitoring can be done remotely, if smart antennas are incorporated on these instruments

  7. Argonne National Laboratory's thermal plume measurements: instruments and techniques

    International Nuclear Information System (INIS)

    Van Loon, L.S.; Frigo, A.A.; Paddock, R.A.

    1977-12-01

    Instrumentation and techniques were developed at Argonne National Laboratory for measuring the three-dimensional temperature structure of thermal plumes from power plants, along with the limnological, meteorological, and plant operating conditions affecting their behavior. The equipment and procedures were designed to provide field data for use in evaluating predictive models that describe thermal plume behavior, and over 100 sets of these data have been collected. The instrument systems and techniques employed in a typical thermal discharge survey are highly integrated. Continuous monitoring of ambient and plant conditions is coupled with plume mapping from a moving survey boat. The instantaneous location of the boat together with subsurface temperature measurements from a towed thermistor chain provide a quasisynoptic view of the plume structure. Real-time, onboard display of the boat path and vertical temperatures supply feedback to investigators for determining the extent and spatial resolution of measurements required. The unique design, reliability, accuracy, calibration, and historical development of the components of these integrated systems are described. Survey system interfaces with data handling and processing techniques are also explained. Special supportive studies to investigate plume dynamics, values of eddy diffusivities, time-temperature histories of water parcels in thermal plumes, and rapid changes in plume shape are also described along with instrumentation used

  8. A Protocol for Advanced Psychometric Assessment of Surveys

    Science.gov (United States)

    Squires, Janet E.; Hayduk, Leslie; Hutchinson, Alison M.; Cranley, Lisa A.; Gierl, Mark; Cummings, Greta G.; Norton, Peter G.; Estabrooks, Carole A.

    2013-01-01

    Background and Purpose. In this paper, we present a protocol for advanced psychometric assessments of surveys based on the Standards for Educational and Psychological Testing. We use the Alberta Context Tool (ACT) as an exemplar survey to which this protocol can be applied. Methods. Data mapping, acceptability, reliability, and validity are addressed. Acceptability is assessed with missing data frequencies and the time required to complete the survey. Reliability is assessed with internal consistency coefficients and information functions. A unitary approach to validity consisting of accumulating evidence based on instrument content, response processes, internal structure, and relations to other variables is taken. We also address assessing performance of survey data when aggregated to higher levels (e.g., nursing unit). Discussion. In this paper we present a protocol for advanced psychometric assessment of survey data using the Alberta Context Tool (ACT) as an exemplar survey; application of the protocol to the ACT survey is underway. Psychometric assessment of any survey is essential to obtaining reliable and valid research findings. This protocol can be adapted for use with any nursing survey. PMID:23401759

  9. Development and validation of an instrument to measure nurse educator perceived confidence in clinical teaching.

    Science.gov (United States)

    Nguyen, Van N B; Forbes, Helen; Mohebbi, Mohammadreza; Duke, Maxine

    2017-12-01

    Teaching nursing in clinical environments is considered complex and multi-faceted. Little is known about the role of the clinical nurse educator, specifically the challenges related to transition from clinician, or in some cases, from newly-graduated nurse to that of clinical nurse educator, as occurs in developing countries. Confidence in the clinical educator role has been associated with successful transition and the development of role competence. There is currently no valid and reliable instrument to measure clinical nurse educator confidence. This study was conducted to develop and psychometrically test an instrument to measure perceived confidence among clinical nurse educators. A multi-phase, multi-setting survey design was used. A total of 468 surveys were distributed, and 363 were returned. Data were analyzed using exploratory and confirmatory factor analyses. The instrument was successfully tested and modified in phase 1, and factorial validity was subsequently confirmed in phase 2. There was strong evidence of internal consistency, reliability, content, and convergent validity of the Clinical Nurse Educator Skill Acquisition Assessment instrument. The resulting instrument is applicable in similar contexts due to its rigorous development and validation process. © 2017 The Authors. Nursing & Health Sciences published by John Wiley & Sons Australia, Ltd.

  10. Redshift Survey Strategies

    Science.gov (United States)

    Jones, A. W.; Bland-Hawthorn, J.; Kaiser, N.

    1994-12-01

    In the first half of 1995, the Anglo-Australian Observatory is due to commission a wide field (2.1(deg) ), 400-fiber, double spectrograph system (2dF) at the f/3.3 prime focus of the AAT 3.9m bi-national facility. The instrument should be able to measure ~ 4000 galaxy redshifts (assuming a magnitude limit of b_J ~\\ 20) in a single dark night and is therefore ideally suited to studies of large-scale structure. We have carried out simple 3D numerical simulations to judge the relative merits of sparse surveys and contiguous surveys. We generate a survey volume and fill it randomly with particles according to a selection function which mimics a magnitude-limited survey at b_J = 19.7. Each of the particles is perturbed by a gaussian random field according to the dimensionless power spectrum k(3) P(k) / 2pi (2) determined by Feldman, Kaiser & Peacock (1994) from the IRAS QDOT survey. We introduce some redshift-space distortion as described by Kaiser (1987), a `thermal' component measured from pairwise velocities (Davis & Peebles 1983), and `fingers of god' due to rich clusters at random density enhancements. Our particular concern is to understand how the window function W(2(k)) of the survey geometry compromises the accuracy of statistical measures [e.g., P(k), xi (r), xi (r_sigma ,r_pi )] commonly used in the study of large-scale structure. We also examine the reliability of various tools (e.g. genus) for describing the topological structure within a contiguous region of the survey.

  11. Management system of instrument database

    International Nuclear Information System (INIS)

    Zhang Xin

    1997-01-01

    The author introduces a management system of instrument database. This system has been developed using with Foxpro on network. The system has some characters such as clear structure, easy operation, flexible and convenient query, as well as the data safety and reliability

  12. Nuclear instrumentation

    International Nuclear Information System (INIS)

    Weill, Jacky; Fabre, Rene.

    1981-01-01

    This article sums up the Research and Development effort at present being carried out in the five following fields of applications: Health physics and Radioprospection, Control of nuclear reactors, Plant control (preparation and reprocessing of the fuel, testing of nuclear substances, etc.), Research laboratory instrumentation, Detectors. It also sets the place of French industrial activities by means of an estimate of the French market, production and flow of trading with other countries [fr

  13. Divided Instruments

    Science.gov (United States)

    Chapman, A.; Murdin, P.

    2000-11-01

    Although the division of the zodiac into 360° probably derives from Egypt or Assyria around 2000 BC, there is no surviving evidence of Mesopotamian cultures embodying this division into a mathematical instrument. Almost certainly, however, it was from Babylonia that the Greek geometers learned of the 360° circle, and by c. 80 BC they had incorporated it into that remarkably elaborate device gener...

  14. Instrumentation development

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Areas being investigated for instrumentation improvement during low-level pollution monitoring include laser opto-acoustic spectroscopy, x-ray fluorescence spectroscopy, optical fluorescence spectroscopy, liquid crystal gas detectors, advanced forms of atomic absorption spectroscopy, electro-analytical chemistry, and mass spectroscopy. Emphasis is also directed toward development of physical methods, as opposed to conventional chemical analysis techniques for monitoring these trace amounts of pollution related to energy development and utilization

  15. Instrumentation maintenance

    International Nuclear Information System (INIS)

    Mack, D.A.

    1976-09-01

    It is essential to any research activity that accurate and efficient measurements be made for the experimental parameters under consideration for each individual experiment or test. Satisfactory measurements in turn depend upon having the necessary instruments and the capability of ensuring that they are performing within their intended specifications. This latter requirement can only be achieved by providing an adequate maintenance facility, staffed with personnel competent to understand the problems associated with instrument adjustment and repair. The Instrument Repair Shop at the Lawrence Berkeley Laboratory is designed to achieve this end. The organization, staffing and operation of this system is discussed. Maintenance policy should be based on studies of (1) preventive vs. catastrophic maintenance, (2) records indicating when equipment should be replaced rather than repaired and (3) priorities established to indicate the order in which equipment should be repaired. Upon establishing a workable maintenance policy, the staff should be instructed so that they may provide appropriate scheduled preventive maintenance, calibration and corrective procedures, and emergency repairs. The education, training and experience of the maintenance staff is discussed along with the organization for an efficient operation. The layout of the various repair shops is described in the light of laboratory space and financial constraints

  16. Reliability of the Anthropometric Indicators of Acute Malnutrition in Pastoralist Populations: Secondary Analysis of a Recent Survey in Bahr-El-Ghazal, Chad

    International Nuclear Information System (INIS)

    Guesdon, Benjamin; Camara, Facely; Ait Aissa, Myriam

    2014-01-01

    Full text: A cross-sectional survey conducted by ACF among the Gorane pastoralist population of the north Bahr-El-Ghazal region, Chad, in April 2013, confirmed the existence of a massive difference in the diagnosis of acute malnutrition according to Mid Upper Arm Circumference (MUAC) and Weight-for-Height Z-score (WHZ), with WHZ returning much larger estimates of acute malnutrition than MUAC. While both indicators are recommended proxies to identify 6 to 59 months old children suffering from non-oedematous acute malnutrition, a previously formulated hypothesis is that WHZ overestimates the diagnosis of acute malnutrition among pastoralist children because of their assumed slender morphology. An alternative hypothesis is that MUAC underestimates acute malnutrition in the older, male, and non-stunted children. We aimed at testing these hypotheses, as well as evaluating if MUAC could be considered as a suitable stand-alone criterion in this context. Besides anthropometric measurements (including sitting height), statements of the caretaker regarding child’s morbidity, loss of weight and lack of food intake has been collected. We first assessed the association between risk factors such as age, sex, stunting and proportion of legs in total body size, and MUAC- or WHZ-based diagnoses. We then described the cases of moderate or severe acute malnutrition diagnosed by WHZ but not by MUAC in terms of slender morphology (high height-for-age and/or long legs compared to the trunk) and vulnerability (anthropometric deficits and caretaker’s anamnesis). Finally, we defined alternative indicators of acute malnutrition by combining subjective statements of the caretaker and anthropometric deficits (underweight without stunting). We assessed if MUAC diagnosis was, more than WHZ, associated with these indicators, first through sensitivity and specificity calculations, then through logistic regression. Analyses were further stratified by legs proportion. Having a high proportion

  17. Developing and testing the CHORDS: Characteristics of Responsible Drinking Survey.

    Science.gov (United States)

    Barry, Adam E; Goodson, Patricia

    2011-01-01

    Report on the development and psychometric testing of a theoretically and evidence-grounded instrument, the Characteristics of Responsible Drinking Survey (CHORDS). Instrument subjected to four phases of pretesting (cognitive validity, cognitive and motivational qualities, pilot test, and item evaluation) and a final posttest implementation. Large public university in Texas. Randomly selected convenience sample (n  =  729) of currently enrolled students. This 78-item questionnaire measures individuals' responsible drinking beliefs, motivations, intentions, and behaviors. Cronbach α, split-half reliability, principal components analysis and Spearman ρ were conducted to investigate reliability, stability, and validity. Measures in the CHORDS exhibited high internal consistency reliability and strong correlations of split-half reliability. Factor analyses indicated five distinct scales were present, as proposed in the theoretical model. Subscale composite scores also exhibited a correlation to alcohol consumption behaviors, indicating concurrent validity. The CHORDS represents the first instrument specifically designed to assess responsible drinking beliefs and behaviors. It was found to elicit valid and reliable data among a college student sample. This instrument holds much promise for practitioners who desire to empirically investigate dimensions of responsible drinking.

  18. Health-related quality of life: validity, reliability, and responsiveness of SF-36, 15D, EQ-5D RAQoL, and HAQ in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Linde, L.; Sørensen, J.; Østergaard, Morten

    2008-01-01

    OBJECTIVE: To compare validity, reliability, and responsiveness of generic and disease specific health-related quality of life (HRQOL) instruments in rheumatoid arthritis (RA). METHODS: Two samples of patients completed the Medical Outcomes Study Short Form-36 Health Survey (SF-36), EuroQol (EQ)-5D...... and VAS pain were responsive to both improvement and deterioration. CONCLUSION: All instruments were valid measures for HRQOL in RA. The RAQoL and HAQ displayed the best reliability, while the SF-36 bodily pain scale and VAS pain were the most responsive. The choice of instrument should depend......, 15D, Rheumatoid Arthritis Quality of Life Scale (RAQoL), Health Assessment Questionnaire (HAQ), and visual analog scales (VAS) for pain, fatigue, and global RA. Validity (convergent, discriminant, and known-groups) was evaluated in a cross-section of 200 patients. Reliability was evaluated...

  19. Assessment of ambient dose equivalent rate performance of an automatic survey meter as an instrument to quantify the presence of radiation