WorldWideScience

Sample records for reliable quantitative solubility

  1. The reliability of sickling and solubility tests and peripheral blood ...

    African Journals Online (AJOL)

    The reliability of sickling and solubility tests and peripheral blood film method for sickle cell disease screening at district health centers in Uganda. ... Les 200 prélèvements des enfants ages de 6 mois à 5 ans ont été analysés de façon indépendante en utilisant la méthode des analyses d'hématies falciformes, la solubilité et ...

  2. Quantitative analysis of soluble elements in environmental waters by PIXE

    International Nuclear Information System (INIS)

    Niizeki, T.; Kawasaki, K.; Adachi, M.; Tsuji, M.; Hattori, T.

    1999-01-01

    We have started PIXE research for environmental science at Van de Graaff accelerator facility in Tokyo Institute of Technology. Quantitative measurements of soluble fractions in river waters have been carried out using the preconcentrate method developed in Tohoku University. We reveal that this PIXE target preparation can be also applied to waste water samples. (author)

  3. A quantitative calculation for software reliability evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young-Jun; Lee, Jang-Soo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    To meet these regulatory requirements, the software used in the nuclear safety field has been ensured through the development, validation, safety analysis, and quality assurance activities throughout the entire process life cycle from the planning phase to the installation phase. A variety of activities, such as the quality assurance activities are also required to improve the quality of a software. However, there are limitations to ensure that the quality is improved enough. Therefore, the effort to calculate the reliability of the software continues for a quantitative evaluation instead of a qualitative evaluation. In this paper, we propose a quantitative calculation method for the software to be used for a specific operation of the digital controller in an NPP. After injecting random faults in the internal space of a developed controller and calculating the ability to detect the injected faults using diagnostic software, we can evaluate the software reliability of a digital controller in an NPP. We tried to calculate the software reliability of the controller in an NPP using a new method that differs from a traditional method. It calculates the fault detection coverage after injecting the faults into the software memory space rather than the activity through the life cycle process. We attempt differentiation by creating a new definition of the fault, imitating the software fault using the hardware, and giving a consideration and weights for injection faults.

  4. The quantitative failure of human reliability analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, C.T.

    1995-07-01

    This philosophical treatise argues the merits of Human Reliability Analysis (HRA) in the context of the nuclear power industry. Actually, the author attacks historic and current HRA as having failed in informing policy makers who make decisions based on risk that humans contribute to systems performance. He argues for an HRA based on Bayesian (fact-based) inferential statistics, which advocates a systems analysis process that employs cogent heuristics when using opinion, and tempers itself with a rational debate over the weight given subjective and empirical probabilities.

  5. Review of Quantitative Software Reliability Methods

    Energy Technology Data Exchange (ETDEWEB)

    Chu, T.L.; Yue, M.; Martinez-Guridi, M.; Lehner, J.

    2010-09-17

    The current U.S. Nuclear Regulatory Commission (NRC) licensing process for digital systems rests on deterministic engineering criteria. In its 1995 probabilistic risk assessment (PRA) policy statement, the Commission encouraged the use of PRA technology in all regulatory matters to the extent supported by the state-of-the-art in PRA methods and data. Although many activities have been completed in the area of risk-informed regulation, the risk-informed analysis process for digital systems has not yet been satisfactorily developed. Since digital instrumentation and control (I&C) systems are expected to play an increasingly important role in nuclear power plant (NPP) safety, the NRC established a digital system research plan that defines a coherent set of research programs to support its regulatory needs. One of the research programs included in the NRC's digital system research plan addresses risk assessment methods and data for digital systems. Digital I&C systems have some unique characteristics, such as using software, and may have different failure causes and/or modes than analog I&C systems; hence, their incorporation into NPP PRAs entails special challenges. The objective of the NRC's digital system risk research is to identify and develop methods, analytical tools, and regulatory guidance for (1) including models of digital systems into NPP PRAs, and (2) using information on the risks of digital systems to support the NRC's risk-informed licensing and oversight activities. For several years, Brookhaven National Laboratory (BNL) has worked on NRC projects to investigate methods and tools for the probabilistic modeling of digital systems, as documented mainly in NUREG/CR-6962 and NUREG/CR-6997. However, the scope of this research principally focused on hardware failures, with limited reviews of software failure experience and software reliability methods. NRC also sponsored research at the Ohio State University investigating the modeling of

  6. Quantitative metal magnetic memory reliability modeling for welded joints

    Science.gov (United States)

    Xing, Haiyan; Dang, Yongbin; Wang, Ben; Leng, Jiancheng

    2016-03-01

    Metal magnetic memory(MMM) testing has been widely used to detect welded joints. However, load levels, environmental magnetic field, and measurement noises make the MMM data dispersive and bring difficulty to quantitative evaluation. In order to promote the development of quantitative MMM reliability assessment, a new MMM model is presented for welded joints. Steel Q235 welded specimens are tested along the longitudinal and horizontal lines by TSC-2M-8 instrument in the tensile fatigue experiments. The X-ray testing is carried out synchronously to verify the MMM results. It is found that MMM testing can detect the hidden crack earlier than X-ray testing. Moreover, the MMM gradient vector sum K vs is sensitive to the damage degree, especially at early and hidden damage stages. Considering the dispersion of MMM data, the K vs statistical law is investigated, which shows that K vs obeys Gaussian distribution. So K vs is the suitable MMM parameter to establish reliability model of welded joints. At last, the original quantitative MMM reliability model is first presented based on the improved stress strength interference theory. It is shown that the reliability degree R gradually decreases with the decreasing of the residual life ratio T, and the maximal error between prediction reliability degree R 1 and verification reliability degree R 2 is 9.15%. This presented method provides a novel tool of reliability testing and evaluating in practical engineering for welded joints.

  7. Quantitative reliability assessment for safety critical system software

    International Nuclear Information System (INIS)

    Chung, Dae Won; Kwon, Soon Man

    2005-01-01

    An essential issue in the replacement of the old analogue I and C to computer-based digital systems in nuclear power plants is the quantitative software reliability assessment. Software reliability models have been successfully applied to many industrial applications, but have the unfortunate drawback of requiring data from which one can formulate a model. Software which is developed for safety critical applications is frequently unable to produce such data for at least two reasons. First, the software is frequently one-of-a-kind, and second, it rarely fails. Safety critical software is normally expected to pass every unit test producing precious little failure data. The basic premise of the rare events approach is that well-tested software does not fail under normal routine and input signals, which means that failures must be triggered by unusual input data and computer states. The failure data found under the reasonable testing cases and testing time for these conditions should be considered for the quantitative reliability assessment. We will present the quantitative reliability assessment methodology of safety critical software for rare failure cases in this paper

  8. Reliability of soluble IL-2 receptor measurements obtained with enzyme-linked immunosorbent assay

    International Nuclear Information System (INIS)

    Akiyama, Mitoshi; Takaishi, Masatoshi; Murakami, Yoshie; Ueda, Ryuzo; Yamakido, Michio; Tsubokura, Tokuo.

    1989-09-01

    Using an enzyme-linked immunosorbent assay (ELISA), human soluble interleukin-2 receptors (IL-2R) were measured in the serum of patients with various autoimmune system diseases. To study the sensitivity and specificity of the assay, soluble IL-2Rs were measured in the culture supernatants and in the cell extracts of peripheral blood mononuclear cells activated with phytohemagglutinin (PHA), purified protein derivative of tuberculin, and allogeneic lymphocytes, as well as in the serum of patients with various collagen diseases. The results correlated well with reports from other laboratories. For example, when stimulated by PHA, the greatest amount of soluble IL-2Rs was produced at the fastest rate. In addition, soluble IL-2R levels in the serum of collagen disease patients were significantly higher than those in healthy persons, who themselves exhibited low levels of detectable soluble IL-2Rs. It is hoped that reliable ELISA measurements of soluble IL-2Rs in the serum of atomic bomb survivors will assist in the interpretation of data collected during the work described in RP 2-87, a study of autoimmunity and autoimmune diseases in the Adult Health Study. (author)

  9. Reproducibility and Reliability of Repeated Quantitative Fluorescence Angiography

    DEFF Research Database (Denmark)

    Nerup, Nikolaj; Knudsen, Kristine Bach Korsholm; Ambrus, Rikard

    2017-01-01

    INTRODUCTION: When using fluorescence angiography (FA) in perioperative perfusion assessment, repeated measures with re-injections of fluorescent dye (ICG) may be required. However, repeated injections may cause saturation of dye in the tissue, exceeding the limit of fluorescence intensity...... that the camera can detect. As the emission of fluorescence is dependent of the excitatory light intensity, reduction of this may solve the problem. The aim of the present study was to investigate the reproducibility and reliability of repeated quantitative FA during a reduction of excitatory light....

  10. [Quantitive variation of polysaccharides and alcohol-soluble extracts in F1 generation of Dendrobium officinale].

    Science.gov (United States)

    Zhang, Xiao-Ling; Liu, Jing-Jing; Wu, Ling-Shang; Si, Jin-Ping; Guo, Ying-Ying; Yu, Jie; Wang, Lin-Hua

    2013-11-01

    Using phenol-sulfuric acid method and hot-dip method of alcohol-soluble extracts, the contents of polysaccharides and alcohol-soluble extracts in 11 F1 generations of Dendrobium officinale were determined. The results showed that the polysaccharides contents in samples collected in May and February were 32.89%-43.07% and 25.77%-35.25%, respectively, while the extracts contents were 2.81%-4.85% and 7.90%-17.40%, respectively. They were significantly different among families. The content of polysaccharides in offspring could be significantly improved by hybridization between parents with low and high polysaccharides contents, and the hybrid vigor was obvious. Cross breeding was an effective way for breeding new varieties with higher polysaccharides contents. Harvest time would significantly affect the contents of polysaccharides and alcohol-soluble extracts. The contents of polysaccharides in families collected in May were higher than those of polysaccharides in families collected in February, but the extracts content had the opposite variation. The extents of quantitative variation of polysaccharides and alcohol-soluble extracts were different among families, and each family had its own rules. It would be significant in giving full play to their role as the excellent varieties and increasing effectiveness by studying on the quantitative accumulation regularity of polysaccharides and alcohol-soluble extracts in superior families (varieties) of D. officinale to determine the best harvesting time.

  11. Quantitative radioimmunoassay for membranous and soluble H-Y antigen typing

    Energy Technology Data Exchange (ETDEWEB)

    Casanova-Bettane, M.; Latron, F.; Jakob, H.; Fellous, M.

    1981-01-01

    Two sensitive and quantitative methods for membranous or soluble H-Y antigen typing using rat anti-H-Y immune sera and /sup 125/I labelled protein A were carried out. These techniques were used to study H-Y antigen expression in human cell lines, and to refine the hypothesis that ..beta../sub 2/m serves as an anchorage point for H-Y antigen.

  12. Reliability of a semi-quantitative method for dermal exposure assessment (DREAM)

    NARCIS (Netherlands)

    Wendel de Joode, B. van; Hemmen, J.J. van; Meijster, T.; Major, V.; London, L.; Kromhout, H.

    2005-01-01

    Valid and reliable semi-quantitative dermal exposure assessment methods for epidemiological research and for occupational hygiene practice, applicable for different chemical agents, are practically nonexistent. The aim of this study was to assess the reliability of a recently developed

  13. Quantitative measurement of hypertrophic scar: interrater reliability and concurrent validity.

    Science.gov (United States)

    Nedelec, Bernadette; Correa, José A; Rachelska, Grazyna; Armour, Alexis; LaSalle, Léo

    2008-01-01

    Research into the pathophysiology and treatment of hypertrophic scar (HSc) remains limited by the heterogeneity of scar and the imprecision with which its severity is measured. The objective of this study was to test the interrater reliability and concurrent validity of the Cutometer measurement of elasticity, the Mexameter measurement of erythema and pigmentation, and total thickness measure of the DermaScan C relative to the modified Vancouver Scar Scale (mVSS) in patient-matched normal skin, normal scar, and HSc. Three independent investigators evaluated 128 sites (severe HSc, moderate or mild HSc, donor site, and normal skin) on 32 burn survivors using all of the above measurement tools. The intraclass correlation coefficient, which was used to measure interrater reliability, reflects the inherent amount of error in the measure and is considered acceptable when it is >0.75. Interrater reliability of the totals of the height, pliability, and vascularity subscales of the mVSS fell below the acceptable limit ( congruent with0.50). The individual subscales of the mVSS fell well below the acceptable level (0.89) for each study site with the exception of severe scar. Mexameter and DermaScan C reliability measurements were acceptable for all sites (>0.82). Concurrent validity correlations with the mVSS were significant except for the comparison of the mVSS pliability subscale and the Cutometer maximum deformation measure comparison in severe scar. In conclusion, the Mexameter and DermaScan C measurements of scar color and thickness of all sites, as well as the Cutometer measurement of elasticity in all but the most severe scars shows high interrater reliability. Their significant concurrent validity with the mVSS confirms that these tools are measuring the same traits as the mVSS, and in a more objective way.

  14. Reliability of quantitative echocardiography in adult sheep and goats

    Directory of Open Access Journals (Sweden)

    Hallowell Gayle D

    2012-09-01

    Full Text Available Abstract Background Echocardiography is a non-invasive method for assessment of the ovine and caprine heart. Complete reference ranges for cardiac dimensions and time indices for both species are not currently available and reliability of these measurements has not been evaluated. The objectives for this study are to report reliability, normal cardiac dimensions and time indices in a large group of adult sheep and goats. Fifty-one adult sheep and forty adult goats were recruited. Full echocardiographic examinations were performed in the standing unsedated animal. All animals underwent echocardiography four times in a 72-hour period. Echocardiography was performed three times by one author and once by another. Images were stored and measured offline. Technique and measurement repeatability and reproducibility and any differences due to animal or day were evaluated. Reference ranges (mean ± 2 standard deviations were calculated for both species. Results Majority of the images obtained were of good to excellent quality. Image acquisition was straightforward with 5.4% of animals demonstrating a small scanning window. Reliability was excellent for majority of dimensions and time indices. There was less variation in repeatability when compared with reproducibility and differences were greater for technique than for measurements. Dimensions that were less reliable included those for right ventricular diameter and left ventricular free wall. There were many differences in cardiac dimensions between sheep and goats. Conclusions This study has demonstrated that specific reference ranges are required for these two species. Repeatability and reproducibility were excellent for the majority of cardiac dimensions and time indices suggesting that this technique is reliable and valuable for examination of clinical cases over time and for longitudinal research studies.

  15. Effect of small mapping population sizes on reliability of quantitative ...

    African Journals Online (AJOL)

    A limitation of quantitative trait loci (QTL) mapping is that accuracy of determining QTL position and effects are largely determined by population size. Despite the importance of this concept, known as the "Beavis effect there has generally been a lack of understanding by molecular geneticists and breeders. One possible ...

  16. A quantitative approach to wind farm diversification and reliability

    Energy Technology Data Exchange (ETDEWEB)

    Degeilh, Yannick; Singh, Chanan [Department of Electrical and Computer Engineering, Texas A and M University, College Station, TX 77843 (United States)

    2011-02-15

    This paper proposes a general planning method to minimize the variance of aggregated wind farm power output by optimally distributing a predetermined number of wind turbines over a preselected number of potential wind farming sites. The objective is to facilitate high wind power penetration through the search for steadier overall power output. Another optimization formulation that takes into account the correlations between wind power outputs and load is also presented. Three years of wind data from the recent NREL/3TIER study in the western US provides the statistics for evaluating each site upon their mean power output, variance and correlation with each other so that the best allocations can be determined. The reliability study reported in this paper investigates the impact of wind power output variance reduction on a power system composed of a virtual wind power plant and a load modeled from the 1996 IEEE RTS. Some traditional reliability indices such as the LOLP are calculated and it is eventually shown that configurations featuring minimal global power output variances generally prove the most reliable provided the sites are not significantly correlated with the modeled load. Consequently, the choice of uncorrelated/negatively correlated sites is favored. (author)

  17. A quantitative approach to wind farm diversification and reliability

    International Nuclear Information System (INIS)

    Degeilh, Yannick; Singh, Chanan

    2011-01-01

    This paper proposes a general planning method to minimize the variance of aggregated wind farm power output by optimally distributing a predetermined number of wind turbines over a preselected number of potential wind farming sites. The objective is to facilitate high wind power penetration through the search for steadier overall power output. Another optimization formulation that takes into account the correlations between wind power outputs and load is also presented. Three years of wind data from the recent NREL/3TIER study in the western US provides the statistics for evaluating each site upon their mean power output, variance and correlation with each other so that the best allocations can be determined. The reliability study reported in this paper investigates the impact of wind power output variance reduction on a power system composed of a virtual wind power plant and a load modeled from the 1996 IEEE RTS. Some traditional reliability indices such as the LOLP are calculated and it is eventually shown that configurations featuring minimal global power output variances generally prove the most reliable provided the sites are not significantly correlated with the modeled load. Consequently, the choice of uncorrelated/negatively correlated sites is favored. (author)

  18. Development of a quantitative bead capture assay for soluble IL-7 receptor alpha in human plasma.

    Directory of Open Access Journals (Sweden)

    Sylvie Faucher

    Full Text Available BACKGROUND: IL-7 is an essential cytokine in T-cell development and homeostasis. It binds to the IL-7R receptor, a complex of the IL-7Ralpha (CD127 and common gamma (CD132 chains. There is significant interest in evaluating the expression of CD127 on human T-cells as it often decreased in medical conditions leading to lymphopenia. Previous reports showed the usefulness of CD127 as a prognostic marker in viral infections such as HIV, CMV, EBV and HCV. A soluble CD127 (sCD127 is released in plasma and may contribute to disease pathogenesis through its control on IL-7 activities. Measuring sCD127 is important to define its role and may complement existing markers used in lymphopenic disease management. We describe a new quantitative assay for the measurement of sCD127 in plasma and report sCD127 concentrations in healthy adults. METHODOLOGY/PRINCIPAL FINDINGS: We developed a quantitative bead-based sCD127 capture assay. Polyclonal CD127-specific antibodies were chosen for capture and a biotinylated monoclonal anti-CD127 antibody was selected for detection. The assay can detect native sCD127 and recombinant sCD127 which served as the calibrator. The analytical performance of the assay was characterized and the concentration and stability of plasma sCD127 in healthy adults was determined. The assay's range was 3.2-1000 ng/mL. The concentration of plasma sCD127 was 164+/-104 ng/mL with over a log variation between subjects. Individual sCD127 concentrations remained stable when measured serially during a period of up to one year. CONCLUSIONS/SIGNIFICANCE: This is the first report on the quantification of plasma sCD127 in a population of healthy adults. Soluble CD127 plasma concentrations remained stable over time in a given individual and sCD127 immunoreactivity was resistant to repeated freeze-thaw cycles. This quantitative sCD127 assay is a valuable tool for defining the potential role of sCD127 in lymphopenic diseases.

  19. The Reliability and Validity of Discrete and Continuous Measures of Psychopathology: A Quantitative Review

    Science.gov (United States)

    Markon, Kristian E.; Chmielewski, Michael; Miller, Christopher J.

    2011-01-01

    In 2 meta-analyses involving 58 studies and 59,575 participants, we quantitatively summarized the relative reliability and validity of continuous (i.e., dimensional) and discrete (i.e., categorical) measures of psychopathology. Overall, results suggest an expected 15% increase in reliability and 37% increase in validity through adoption of a…

  20. Quantitative measurement of hypertrophic scar: intrarater reliability, sensitivity, and specificity.

    Science.gov (United States)

    Nedelec, Bernadette; Correa, José A; Rachelska, Grazyna; Armour, Alexis; LaSalle, Léo

    2008-01-01

    The comparison of scar evaluation over time requires measurement tools with acceptable intrarater reliability and the ability to discriminate skin characteristics of interest. The objective of this study was to evaluate the intrarater reliability and sensitivity and specificity of the Cutometer, the Mexameter, and the DermaScan C relative to the modified Vancouver Scar Scale (mVSS) in patient-matched normal skin, normal scar (donor sites), and hypertrophic scar (HSc). A single investigator evaluated four tissue types (severe HSc, less severe HSc, donor site, and normal skin) in 30 burn survivors with all four measurement tools. The intraclass correlation coefficient (ICC) for the Cutometer was acceptable (> or =0.75) for the maximum deformation measure for the donor site and normal skin (>0.78) but was below the acceptable range for the HSc sites and all other parameters. The ICC for the Mexameter erythema (>0.75) and melanin index (>0.89) and the DermaScan C total thickness measurement (>0.82) were acceptable for all sites. The ICC for the total of the height, pliability, and vascularity subscales of the mVSS was acceptable (0.81) for normal scar but below the acceptable range for the scar sites. The DermaScan C was clearly able to discriminate HSc from normal scar and normal skin based on the total thickness measure. The Cutometer was less discriminating but was still able to discriminate HSc from normal scar and normal skin. The Mexameter erythema index was not a good discriminator of HSc and normal scar. Receiver operating characteristic curves were generated to establish the best cutoff point for the DermaScan C total thickness and the Cutometer maximum deformation, which were 2.034 and 0.387 mm, respectively. This study showed that although the Cutometer, the DermaScan C, and the Mexameter have measurement properties that make them attractive substitutes for the mVSS, caution must be used when interpreting results since the Cutometer has a ceiling effect when

  1. Qualitative and quantitative reliability analysis of safety systems

    International Nuclear Information System (INIS)

    Karimi, R.; Rasmussen, N.; Wolf, L.

    1980-05-01

    A code has been developed for the comprehensive analysis of a fault tree. The code designated UNRAC (UNReliability Analysis Code) calculates the following characteristics of an input fault tree: (1) minimal cut sets; (2) top event unavailability as point estimate and/or in time dependent form; (3) quantitative importance of each component involved; and, (4) error bound on the top event unavailability. UNRAC can analyze fault trees, with any kind of gates (EOR, NAND, NOR, AND, OR), up to a maximum of 250 components and/or gates. The code is benchmarked against WAMCUT, MODCUT, KITT, BIT-FRANTIC, and PL-MODT. The results showed that UNRAC produces results more consistent with the KITT results than either BIT-FRANTIC or PL-MODT. Overall it is demonstrated that UNRAC is an efficient easy-to-use code and has the advantage of being able to do a complete fault tree analysis with this single code. Applications of fault tree analysis to safety studies of nuclear reactors are considered

  2. the reliability of sickling and solubility tests and peripheral blood film

    African Journals Online (AJOL)

    Clinics in Mother and Child Health Vol 7, N°1, June 2010. THE RELIABILITY OF ... PERIPHERAL BLOOD FILM METHOD FOR SICKLE CELL DISEASE. SCREENING AT .... used in Jamaica as a confirmatory procedure [4], its use in most of the.

  3. Verification of practicability of quantitative reliability evaluation method (De-BDA) in nuclear power plants

    International Nuclear Information System (INIS)

    Takahashi, Kinshiro; Yukimachi, Takeo.

    1988-01-01

    A variety of methods have been applied to study of reliability analysis in which human factors are included in order to enhance the safety and availability of nuclear power plants. De-BDA (Detailed Block Diagram Analysis) is one of such mehtods developed with the objective of creating a more comprehensive and understandable tool for quantitative analysis of reliability associated with plant operations. The practicability of this method has been verified by applying it to reliability analysis of various phases of plant operation as well as evaluation of enhanced man-machine interface in the central control room. (author)

  4. Quantitative characterization of the reliability of simplex buses and stars to compare their benefits in fieldbuses

    International Nuclear Information System (INIS)

    Barranco, Manuel; Proenza, Julián; Almeida, Luís

    2015-01-01

    Fieldbuses targeted to highly dependable distributed embedded systems are shifting from bus to star topologies. Surprisingly, despite the efforts into this direction, engineers lack of analyses that quantitatively characterize the system reliability achievable by buses and stars. Thus, to guide engineers in developing adequate bus and star fieldbuses, this work models, quantifies and compares the system reliability provided by simplex buses and stars for the case of the Controller Area Network (CAN). It clarifies how relevant dependability-related aspects affect reliability, refuting some intuitive ideas, and revealing some previously unknown bus and star benefits. - Highlights: • SANs models that quantify the reliability of simplex buses/stars in fieldbuses. • Models cover system relevant dependability-related features abstracted in the literature. • Results refute intuitive ideas about buses and stars and show some unexpected effects. • Models and results can guide the design of reliable simplex bus/stars fieldbuses

  5. A Bayesian belief nets based quantitative software reliability assessment for PSA: COTS case study

    International Nuclear Information System (INIS)

    Eom, H. S.; Sung, T. Y.; Jeong, H. S.; Park, J. H.; Kang, H. G.; Lee, K. Y.; Park, J. K

    2002-03-01

    Current reliability assessments of safety critical software embedded in the digital systems in nuclear power plants are based on the rule-based qualitative assessment methods. Then recently practical needs require the quantitative features of software reliability for Probabilistic Safety Assessment (PSA) that is one of important methods being used in assessing the whole safety of nuclear power plant. But conventional quantitative software reliability assessment methods are not enough to get the necessary results in assessing the safety critical software used in nuclear power plants. Thus, current reliability assessment methods for these digital systems exclude the software part or use arbitrary values for the software reliability in the assessment. This reports discusses a Bayesian Belief Nets (BBN) based quantification method that models current qualitative software assessment in formal way and produces quantitative results required for PSA. Commercial Off-The-Shelf (COTS) software dedication process that KAERI developed was applied to the discussed BBN based method for evaluating the plausibility of the proposed method in PSA

  6. Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience

    Directory of Open Access Journals (Sweden)

    Michael O. Harris-Love

    2016-06-01

    Full Text Available Background. Quantitative ultrasound measures are influenced by multiple external factors including examiner scanning force. Force feedback may foster the acquisition of reliable morphometry measures under a variety of scanning conditions. The purpose of this study was to determine the reliability of force-feedback image acquisition and morphometry over a range of examiner-generated forces using a muscle tissue-mimicking ultrasound phantom. Methods. Sixty material thickness measures were acquired from a muscle tissue mimicking phantom using B-mode ultrasound scanning by six examiners with varied experience levels (i.e., experienced, intermediate, and novice. Estimates of interrater reliability and measurement error with force feedback scanning were determined for the examiners. In addition, criterion-based reliability was determined using material deformation values across a range of examiner scanning forces (1–10 Newtons via automated and manually acquired image capture methods using force feedback. Results. All examiners demonstrated acceptable interrater reliability (intraclass correlation coefficient, ICC = .98, p .90, p < .001, independent of their level of experience. The measurement error among all examiners was 1.5%–2.9% across all applied stress conditions. Conclusion. Manual image capture with force feedback may aid the reliability of morphometry measures across a range of examiner scanning forces, and allow for consistent performance among examiners with differing levels of experience.

  7. Regional reliability of quantitative signal targeting with alternating radiofrequency (STAR) labeling of arterial regions (QUASAR).

    Science.gov (United States)

    Tatewaki, Yasuko; Higano, Shuichi; Taki, Yasuyuki; Thyreau, Benjamin; Murata, Takaki; Mugikura, Shunji; Ito, Daisuke; Takase, Kei; Takahashi, Shoki

    2014-01-01

    Quantitative signal targeting with alternating radiofrequency labeling of arterial regions (QUASAR) is a recent spin labeling technique that could improve the reliability of brain perfusion measurements. Although it is considered reliable for measuring gray matter as a whole, it has never been evaluated regionally. Here we assessed this regional reliability. Using a 3-Tesla Philips Achieva whole-body system, we scanned four times 10 healthy volunteers, in two sessions 2 weeks apart, to obtain QUASAR images. We computed perfusion images and ran a voxel-based analysis within all brain structures. We also calculated mean regional cerebral blood flow (rCBF) within regions of interest configured for each arterial territory distribution. The mean CBF over whole gray matter was 37.74 with intraclass correlation coefficient (ICC) of .70. In white matter, it was 13.94 with an ICC of .30. Voxel-wise ICC and coefficient-of-variation maps showed relatively lower reliability in watershed areas and white matter especially in deeper white matter. The absolute mean rCBF values were consistent with the ones reported from PET, as was the relatively low variability in different feeding arteries. Thus, QUASAR reliability for regional perfusion is high within gray matter, but uncertain within white matter. © 2014 The Authors. Journal of Neuroimaging published by the American Society of Neuroimaging.

  8. High pressure liquid chromatographic method for the separation and quantitation of water-soluble radiolabeled benzene metabolites

    International Nuclear Information System (INIS)

    Sabourin, P.J.; Bechtold, W.E.; Henderson, R.F.

    1988-01-01

    The glucuronide and sulfate conjugates of benzene metabolite as well as muconic acid and pre-phenyl- and phenylmercapturic acids were separated by ion-pairing HPLC. The HPLC method developed was suitable for automated analysis of a large number of tissue or excreta samples. p-Nitrophenyl [ 14 C]glucuronide was used as an internal standard for quantitation of these water-soluble metabolites. Quantitation was verified by spiking liver tissue with various amounts of phenylsulfate or glucuronides of phenol, catechol, or hydroquinone and analyzing by HPLC. Values determined by HPLC analysis were within 10% of the actual amount with which the liver was spiked. The amount of metabolite present in urine following exposure to [ 3 H]benzene was determined using p-nitrophenyl [ 14 C]glucuronide as an internal standard. Phenylsulfate was the major water-soluble metabolite in the urine of F344 rats exposed to 50 ppm [ 3 H]benzene for 6 h. Muconic acid and an unknown metabolite which decomposed in acidic media to phenylmercapturic acid were also present. Liver, however, contained a different metabolic profile. This indicates that urinary metabolite profiles may not be a true reflection of what is seen in individual tissues

  9. Solubility behavior of quartz and corundum in supercritical water: A quantitative thermodynamic interpretation

    International Nuclear Information System (INIS)

    Ziemniak, S.E.

    1995-05-01

    Dissolution reaction equilibria for α-quartz (SiO 2 ) and corundum (α-Al 2 0 3 ) in pure, supercritical water are quantified using a density-dependent thermodynamic model. The database of existing solubility literature for α-quartz (0.2-10 kb, 200--575 degrees C) is shown to be consistent with the presence of two hydrolyzed SI(IV) ion forms: Si(OH) 4 (aq) and Si 2 O(OH) 6 (aq); the corundum database (1-20 kb, 400--700 degrees C) is consistent with Al(OH) 3 (aq) and Al(OH) 4 - . A third Si(IV) ion hydroxocomplex, Si 2 O 2 (OH) 5 - , is indicated at lower pressures (0.03-0.10 kb). The characteristic sigmoidal nature of the solubility isobars is explained by dimerization of Si(OH) 4 (aq) (at high densities) or the formation of anionic hydrolysis products, Si 2 0 2 (OH) 5 - and Al(OH) 4 - , in the low density region (p 2 O(OH) 6 (aq) and Si 2 O 2 (OH) 5 - are made available for the first time

  10. HILIC separation and quantitation of water-soluble vitamins using diol column.

    Science.gov (United States)

    Karatapanis, Andreas E; Fiamegos, Yiannis C; Stalikas, Constantine D

    2009-04-01

    Hydrophilic interaction liquid-chromatography (HILIC) in conjunction with diode array detection has been applied for the separation of selected-water-soluble vitamins using an end-capped HILIC-diol column. Vitamins with significant biological importance, such as thiamine (B(1)), riboflavin (B(2)), nicotinic acid (B(3)), nicotinamide (B(3)), pyridoxine (B(6)), folic acid (B(9)), cyanocobalamin (B(12)) and ascorbic acid (vitamin C) were simultaneously separated. Chromatographic conditions including type and percentage of organic modifier in the mobile phase, pH, type and concentration of buffer salt and flow rate were investigated. ACN was shown to offer superior separation for the compounds tested as compared to methanol, isopropanol and THF. Isocratic separation and analysis were achieved for six vitamins (B(1), B(2), nicotinic acid/nicotinamide, B(6) and C) at ACN-H(2)O 90:10, containing ammonium acetate 10 mM, triethylamine 20 mM, pH 5.0, using a flow rate of 0.8 mL/min, while a gradient was necessary to resolve a mixture of all eight water-soluble vitamins. The HILIC method was validated and successfully applied to the analysis of a pharmaceutical formulation and an energy drink negating the need for time consuming clean-up steps.

  11. Test-retest Agreement and Reliability of Quantitative Sensory Testing 1 Year After Breast Cancer Surgery

    DEFF Research Database (Denmark)

    Andersen, Kenneth Geving; Kehlet, Henrik; Aasvang, Eske Kvanner

    2015-01-01

    .5 SD) than within-patient variation (0.23 to 3.55 SD). There were no significant differences between pain and pain-free patients. The individual test-retest variability was higher on the operated side compared with the nonoperated side. DISCUSSION: The QST protocol reliability allows for group......OBJECTIVES: Quantitative sensory testing (QST) is used to assess sensory dysfunction and nerve damage by examining psychophysical responses to controlled, graded stimuli such as mechanical and thermal detection and pain thresholds. In the breast cancer population, 4 studies have used QST to examine...... persistent pain after breast cancer treatment, suggesting neuropathic pain being a prominent pain mechanism. However, the agreement and reliability of QST has not been described in the postsurgical breast cancer population, hindering exact interpretation of QST studies in this population. The aim...

  12. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  13. Quantitative outcome measures for systemic sclerosis-related Microangiopathy - Reliability of image acquisition in Nailfold Capillaroscopy.

    Science.gov (United States)

    Dinsdale, Graham; Moore, Tonia; O'Leary, Neil; Berks, Michael; Roberts, Christopher; Manning, Joanne; Allen, John; Anderson, Marina; Cutolo, Maurizio; Hesselstrand, Roger; Howell, Kevin; Pizzorni, Carmen; Smith, Vanessa; Sulli, Alberto; Wildt, Marie; Taylor, Christopher; Murray, Andrea; Herrick, Ariane L

    2017-09-01

    Nailfold capillaroscopic parameters hold increasing promise as outcome measures for clinical trials in systemic sclerosis (SSc). Their inclusion as outcomes would often naturally require capillaroscopy images to be captured at several time points during any one study. Our objective was to assess repeatability of image acquisition (which has been little studied), as well as of measurement. 41 patients (26 with SSc, 15 with primary Raynaud's phenomenon) and 10 healthy controls returned for repeat high-magnification (300×) videocapillaroscopy mosaic imaging of 10 digits one week after initial imaging (as part of a larger study of reliability). Images were assessed in a random order by an expert blinded observer and 4 outcome measures extracted: (1) overall image grade and then (where possible) distal vessel locations were marked, allowing (2) vessel density (across the whole nailfold) to be calculated (3) apex width measurement and (4) giant vessel count. Intra-rater, intra-visit and intra-rater inter-visit (baseline vs. 1week) reliability were examined in 475 and 392 images respectively. A linear, mixed-effects model was used to estimate variance components, from which intra-class correlation coefficients (ICCs) were determined. Intra-visit and inter-visit reliability estimates (ICCs) were (respectively): overall image grade, 0.97 and 0.90; vessel density, 0.92 and 0.65; mean vessel width, 0.91 and 0.79; presence of giant capillary, 0.68 and 0.56. These estimates were conditional on each parameter being measurable. Within-operator image analysis and acquisition are reproducible. Quantitative nailfold capillaroscopy, at least with a single observer, provides reliable outcome measures for clinical studies including randomised controlled trials. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Reliability of multiparametric prostatic MRI quantitative data in the evaluation of prostate cancer aggressiveness

    Directory of Open Access Journals (Sweden)

    Haisam Atta

    2017-09-01

    Full Text Available Purpose: To compare the quantitative data of multiparametric prostatic MRI with Gleason scores of histopathological analysis. Materials and methods: One hundred twenty-two patients performed Multiparametric MRI of the prostate. Functional MRI quantitative data (including diffusion with mean ADC value and spectroscopic metabolic ratio where the DWI is employing b 50, 400, 800, 1000 and 2000 sec/mm2 and multivoxel MR spectroscopy compared with of Gleason scores of histopathological results. Malignant cases are classified into three groups according to their Gleason score as group I with Gleason score ≤6, group II Gleason score 7, while Gleason score 8–10 stratified as Group III. Results: The histopathological analysis reveals 78 malignant cases and 44 benign Cases. The significant statistical difference between group I and the other two groups (p < 0.001 regarding the quantitative mean ADC value and metabolic spectroscopic ratio. No significant statistical difference between group II and III with p = 0.2 for mean ADC difference and p = 0.8 for the metabolic spectroscopic ratio with a weak negative correlation between ADCand Gleason score [rs = −0.26] and significant positive correlation (p = 0.02 for MRSI metabolic ratio [rs = 0.2]. Conclusion: The quantitative data of functional imaging of the prostate is reliable in evaluating prostatic cancer aggressiveness and proper construction of therapeutic plan. Keywords: mpMRI prostate cancer aggressiveness

  15. Reference gene identification for reliable normalisation of quantitative RT-PCR data in Setaria viridis.

    Science.gov (United States)

    Nguyen, Duc Quan; Eamens, Andrew L; Grof, Christopher P L

    2018-01-01

    Quantitative real-time polymerase chain reaction (RT-qPCR) is the key platform for the quantitative analysis of gene expression in a wide range of experimental systems and conditions. However, the accuracy and reproducibility of gene expression quantification via RT-qPCR is entirely dependent on the identification of reliable reference genes for data normalisation. Green foxtail ( Setaria viridis ) has recently been proposed as a potential experimental model for the study of C 4 photosynthesis and is closely related to many economically important crop species of the Panicoideae subfamily of grasses, including Zea mays (maize), Sorghum bicolor (sorghum) and Sacchurum officinarum (sugarcane). Setaria viridis (Accession 10) possesses a number of key traits as an experimental model, namely; (i) a small sized, sequenced and well annotated genome; (ii) short stature and generation time; (iii) prolific seed production, and; (iv) is amendable to Agrobacterium tumefaciens -mediated transformation. There is currently however, a lack of reference gene expression information for Setaria viridis ( S. viridis ). We therefore aimed to identify a cohort of suitable S. viridis reference genes for accurate and reliable normalisation of S. viridis RT-qPCR expression data. Eleven putative candidate reference genes were identified and examined across thirteen different S. viridis tissues. Of these, the geNorm and NormFinder analysis software identified SERINE / THERONINE - PROTEIN PHOSPHATASE 2A ( PP2A ), 5 '- ADENYLYLSULFATE REDUCTASE 6 ( ASPR6 ) and DUAL SPECIFICITY PHOSPHATASE ( DUSP ) as the most suitable combination of reference genes for the accurate and reliable normalisation of S. viridis RT-qPCR expression data. To demonstrate the suitability of the three selected reference genes, PP2A , ASPR6 and DUSP , were used to normalise the expression of CINNAMYL ALCOHOL DEHYDROGENASE ( CAD ) genes across the same tissues. This approach readily demonstrated the suitably of the three

  16. Survey of bayesian belif nets for quantitative reliability assessment of safety critical software used in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Eom, H.S.; Sung, T.Y.; Jeong, H.S.; Park, J.H.; Kang, H.G.; Lee, K

    2001-03-01

    As part of the Probabilistic Safety Assessment of safety grade digital systems used in Nuclear Power plants research, measures and methodologies applicable to quantitative reliability assessment of safety critical software were surveyed. Among the techniques proposed in the literature we selected those which are in use widely and investigated their limitations in quantitative software reliability assessment. One promising methodology from the survey is Bayesian Belief Nets (BBN) which has a formalism and can combine various disparate evidences relevant to reliability into final decision under uncertainty. Thus we analyzed BBN and its application cases in digital systems assessment area and finally studied the possibility of its application to the quantitative reliability assessment of safety critical software.

  17. Survey of bayesian belif nets for quantitative reliability assessment of safety critical software used in nuclear power plants

    International Nuclear Information System (INIS)

    Eom, H. S.; Sung, T. Y.; Jeong, H. S.; Park, J. H.; Kang, H. G.; Lee, K.

    2001-03-01

    As part of the Probabilistic Safety Assessment of safety grade digital systems used in Nuclear Power plants research, measures and methodologies applicable to quantitative reliability assessment of safety critical software were surveyed. Among the techniques proposed in the literature we selected those which are in use widely and investigated their limitations in quantitative software reliability assessment. One promising methodology from the survey is Bayesian Belief Nets (BBN) which has a formalism and can combine various disparate evidences relevant to reliability into final decision under uncertainty. Thus we analyzed BBN and its application cases in digital systems assessment area and finally studied the possibility of its application to the quantitative reliability assessment of safety critical software

  18. Plutonium chemistry: a synthesis of experimental data and a quantitative model for plutonium oxide solubility

    International Nuclear Information System (INIS)

    Haschke, J.M.; Oversby, V.M.

    2002-01-01

    The chemistry of plutonium is important for assessing potential behavior of radioactive waste under conditions of geologic disposal. This paper reviews experimental data on dissolution of plutonium oxide solids, describes a hybrid kinetic-equilibrium model for predicting steady-state Pu concentrations, and compares laboratory results with predicted Pu concentrations and oxidation-state distributions. The model is based on oxidation of PuO 2 by water to produce PuO 2+x , an oxide that can release Pu(V) to solution. Kinetic relationships between formation of PuO 2+x , dissolution of Pu(V), disproportionation of Pu(V) to Pu(IV) and Pu(VI), and reduction of Pu(VI) are given and used in model calculations. Data from tests of pyrochemical salt wastes in brines are discussed and interpreted using the conceptual model. Essential data for quantitative modeling at conditions relevant to nuclear waste repositories are identified and laboratory experiments to determine rate constants for use in the model are discussed

  19. Quantitative trait loci markers derived from whole genome sequence data increases the reliability of genomic prediction

    DEFF Research Database (Denmark)

    Brøndum, Rasmus Froberg; Su, Guosheng; Janss, Luc

    2015-01-01

    This study investigated the effect on the reliability of genomic prediction when a small number of significant variants from single marker analysis based on whole genome sequence data were added to the regular 54k single nucleotide polymorphism (SNP) array data. The extra markers were selected...... with the aim of augmenting the custom low-density Illumina BovineLD SNP chip (San Diego, CA) used in the Nordic countries. The single-marker analysis was done breed-wise on all 16 index traits included in the breeding goals for Nordic Holstein, Danish Jersey, and Nordic Red cattle plus the total merit index...... itself. Depending on the trait’s economic weight, 15, 10, or 5 quantitative trait loci (QTL) were selected per trait per breed and 3 to 5 markers were selected to tag each QTL. After removing duplicate markers (same marker selected for more than one trait or breed) and filtering for high pairwise linkage...

  20. Quantitative software-reliability analysis of computer codes relevant to nuclear safety

    International Nuclear Information System (INIS)

    Mueller, C.J.

    1981-12-01

    This report presents the results of the first year of an ongoing research program to determine the probability of failure characteristics of computer codes relevant to nuclear safety. An introduction to both qualitative and quantitative aspects of nuclear software is given. A mathematical framework is presented which will enable the a priori prediction of the probability of failure characteristics of a code given the proper specification of its properties. The framework consists of four parts: (1) a classification system for software errors and code failures; (2) probabilistic modeling for selected reliability characteristics; (3) multivariate regression analyses to establish predictive relationships among reliability characteristics and generic code property and development parameters; and (4) the associated information base. Preliminary data of the type needed to support the modeling and the predictions of this program are described. Illustrations of the use of the modeling are given but the results so obtained, as well as all results of code failure probabilities presented herein, are based on data which at this point are preliminary, incomplete, and possibly non-representative of codes relevant to nuclear safety

  1. Reliability and group differences in quantitative cervicothoracic measures among individuals with and without chronic neck pain

    Science.gov (United States)

    2012-01-01

    Background Clinicians frequently rely on subjective categorization of impairments in mobility, strength, and endurance for clinical decision-making; however, these assessments are often unreliable and lack sensitivity to change. The objective of this study was to determine the inter-rater reliability, minimum detectable change (MDC), and group differences in quantitative cervicothoracic measures for individuals with and without chronic neck pain (NP). Methods Nineteen individuals with NP and 20 healthy controls participated in this case control study. Two physical therapists performed a 30-minute examination on separate days. A handheld dynamometer, gravity inclinometer, ruler, and stopwatch were used to quantify cervical range of motion (ROM), cervical muscle strength and endurance, and scapulothoracic muscle length and strength, respectively. Results Intraclass correlation coefficients for inter-rater reliability were significantly greater than zero for most impairment measures, with point estimates ranging from 0.45 to 0.93. The NP group exhibited reduced cervical ROM (P ≤ 0.012) and muscle strength (P ≤ 0.038) in most movement directions, reduced cervical extensor endurance (P = 0.029), and reduced rhomboid and middle trapezius muscle strength (P ≤ 0.049). Conclusions Results demonstrate the feasibility of obtaining objective cervicothoracic impairment measures with acceptable inter-rater agreement across time. The clinical utility of these measures is supported by evidence of impaired mobility, strength, and endurance among patients with NP, with corresponding MDC values that can help establish benchmarks for clinically significant change. PMID:23114092

  2. Three dimensional quantitative coronary angiography can detect reliably ischemic coronary lesions based on fractional flow reserve.

    Science.gov (United States)

    Chung, Woo-Young; Choi, Byoung-Joo; Lim, Seong-Hoon; Matsuo, Yoshiki; Lennon, Ryan J; Gulati, Rajiv; Sandhu, Gurpreet S; Holmes, David R; Rihal, Charanjit S; Lerman, Amir

    2015-06-01

    Conventional coronary angiography (CAG) has limitations in evaluating lesions producing ischemia. Three dimensional quantitative coronary angiography (3D-QCA) shows reconstructed images of CAG using computer based algorithm, the Cardio-op B system (Paieon Medical, Rosh Ha'ayin, Israel). The aim of this study was to evaluate whether 3D-QCA can reliably predict ischemia assessed by myocardial fractional flow reserve (FFR) < 0.80. 3D-QCA images were reconstructed from CAG which also were evaluated with FFR to assess ischemia. Minimal luminal diameter (MLD), percent diameter stenosis (%DS), minimal luminal area (MLA), and percent area stenosis (%AS) were obtained. The results of 3D-QCA and FFR were compared. A total of 266 patients was enrolled for the present study. FFR for all lesions ranged from 0.57 to 1.00 (0.85 ± 0.09). Measurement of MLD, %DS, MLA, and %AS all were significantly correlated with FFR (r = 0.569, 0609, 0.569, 0.670, respectively, all P < 0.001). In lesions with MLA < 4.0 mm(2), %AS of more than 65.5% had a 80% sensitivity and a 83% specificity to predict FFR < 0.80 (area under curve, AUC was 0.878). 3D-QCA can reliably predict coronary lesions producing ischemia and may be used to guide therapeutic approach for coronary artery disease.

  3. Quantitative dynamic reliability evaluation of AP1000 passive safety systems by using FMEA and GO-FLOW methodology

    International Nuclear Information System (INIS)

    Hashim Muhammad; Yoshikawa, Hidekazu; Matsuoka, Takeshi; Yang Ming

    2014-01-01

    The passive safety systems utilized in advanced pressurized water reactor (PWR) design such as AP1000 should be more reliable than that of active safety systems of conventional PWR by less possible opportunities of hardware failures and human errors (less human intervention). The objectives of present study are to evaluate the dynamic reliability of AP1000 plant in order to check the effectiveness of passive safety systems by comparing the reliability-related issues with that of active safety systems in the event of the big accidents. How should the dynamic reliability of passive safety systems properly evaluated? And then what will be the comparison of reliability results of AP1000 passive safety systems with the active safety systems of conventional PWR. For this purpose, a single loop model of AP1000 passive core cooling system (PXS) and passive containment cooling system (PCCS) are assumed separately for quantitative reliability evaluation. The transient behaviors of these passive safety systems are taken under the large break loss-of-coolant accident in the cold leg. The analysis is made by utilizing the qualitative method failure mode and effect analysis in order to identify the potential failure mode and success-oriented reliability analysis tool called GO-FLOW for quantitative reliability evaluation. The GO-FLOW analysis has been conducted separately for PXS and PCCS systems under the same accident. The analysis results show that reliability of AP1000 passive safety systems (PXS and PCCS) is increased due to redundancies and diversity of passive safety subsystems and components, and four stages automatic depressurization system is the key subsystem for successful actuation of PXS and PCCS system. The reliability results of PCCS system of AP1000 are more reliable than that of the containment spray system of conventional PWR. And also GO-FLOW method can be utilized for reliability evaluation of passive safety systems. (author)

  4. Quantitative evaluation of the impact of human reliability in risk assessment for nuclear power plants

    International Nuclear Information System (INIS)

    Samanta, P.K.

    1981-01-01

    The role of human beings in the safe operation of a nuclear power plant has been a matter of concern. This study describes methods for the quantitative description of that role and its impact on the risk from nuclear power plants. The impact of human errors was calculated by observing the changes in risk parameters, such as core melt probability, release category probabilities, accident sequence probabilities and system unavailabilities due to changes in the contribution to unavailablity of human errors, within the framework of risk assessment methodology. It was found that for operational pressurized water reactors the opportunity for reduction in core melt probability by reducing the human error rates without simultaneous reduction of hardware failures is limited, but that core melt probability would significantly increase as human error rates increased. More importantly, most of the dominant accident sequences showed a significant increase in their probabilities with an increase in human error rates. Release categories resulting in high consequences showed a much larger sensitivity to human errors than categories resulting in low consequences. A combination of structural importance and reliability importance measure was used to describe the importance of individual errors

  5. FURAX: assistance tools for the qualitative and quantitative analysis of systems reliability

    International Nuclear Information System (INIS)

    Moureau, R.

    1995-01-01

    FURAX is a set of tools for the qualitative and quantitative safety analysis of systems functioning. It is particularly well adapted to the study of networks (fluids, electrical..), i.e. systems in which importance is functionally given to a flux. The analysis is based on modeling which privileges these fluxes (skeleton representation of the system for a network, functional diagram for a non single-flux system) and on the representation of components support systems. Qualitative analyses are based on the research for possible flux ways and on the technical domain knowledge. The results obtained correspond to a simplified failure mode analysis, to fault-trees relative to the events expected by the user and to minimum sections. The possible calculations on these models are: tree calculations, Markov diagram calculations of the system reliability, and probabilistic calculation of a section viewed as a tree, as a well-ordered sequence of failures, or as the absorbing state of a Markov diagram. (J.S.). 6 refs

  6. Reliability of Reagent Strips for Semi-quantitative Measurement of Glucosuria in a Neonatal Intensive Care Setting

    Directory of Open Access Journals (Sweden)

    Jolita Bekhof

    2014-12-01

    Conclusion: The reliability of the semi-quantitative measurement of glucosuria in newborn infants using reagent strips is good, even under the conditions of a NICU. Changes in the rating of reagent strips of more than one category are most likely to be beyond measurement error.

  7. A study on the quantitative evaluation of the reliability for safety critical software using Bayesian belief nets

    International Nuclear Information System (INIS)

    Eom, H. S.; Jang, S. C.; Ha, J. J.

    2003-01-01

    Despite the efforts to avoid undesirable risks, or at least to bring them under control in the world, new risks that are highly difficult to manage continue to emerge from the use of new technologies, such as the use of digital instrumentation and control (I and C) components in nuclear power plant. Whenever new risk issues came out by now, we have endeavored to find the most effective ways to reduce risks, or to allocate limited resources to do this. One of the major challenges is the reliability analysis of safety-critical software associated with digital safety systems. Though many activities such as testing, verification and validation (V and V) techniques have been carried out in the design stage of software, however, the process of quantitatively evaluating the reliability of safety-critical software has not yet been developed because of the irrelevance of the conventional software reliability techniques to apply for the digital safety systems. This paper focuses on the applicability of Bayesian Belief Net (BBN) techniques to quantitatively estimate the reliability of safety-critical software adopted in digital safety system. In this paper, a typical BBN model was constructed using the dedication process of the Commercial-Off-The-Shelf (COTS) installed by KAERI. In conclusion, the adoption of BBN technique can facilitate the process of evaluating the safety-critical software reliability in nuclear power plant, as well as provide very useful information (e.g., 'what if' analysis) associated with software reliability in the viewpoint of practicality

  8. Reliability of intra-oral quantitative sensory testing (QST) in patients with atypical odontalgia and healthy controls - a multicentre study.

    Science.gov (United States)

    Baad-Hansen, L; Pigg, M; Yang, G; List, T; Svensson, P; Drangsholt, M

    2015-02-01

    The reliability of comprehensive intra-oral quantitative sensory testing (QST) protocol has not been examined systematically in patients with chronic oro-facial pain. The aim of the present multicentre study was to examine test-retest and interexaminer reliability of intra-oral QST measures in terms of absolute values and z-scores as well as within-session coefficients of variation (CV) values in patients with atypical odontalgia (AO) and healthy pain-free controls. Forty-five patients with AO and 68 healthy controls were subjected to bilateral intra-oral gingival QST and unilateral extratrigeminal QST (thenar) on three occasions (twice on 1 day by two different examiners and once approximately 1 week later by one of the examiners). Intra-class correlation coefficients and kappa values for interexaminer and test-retest reliability were computed. Most of the standardised intra-oral QST measures showed fair to excellent interexaminer (9-12 of 13 measures) and test-retest (7-11 of 13 measures) reliability. Furthermore, no robust differences in reliability measures or within-session variability (CV) were detected between patients with AO and the healthy reference group. These reliability results in chronic orofacial pain patients support earlier suggestions based on data from healthy subjects that intra-oral QST is sufficiently reliable for use as a part of a comprehensive evaluation of patients with somatosensory disturbances or neuropathic pain in the trigeminal region. © 2014 John Wiley & Sons Ltd.

  9. A technical survey on issues of the quantitative evaluation of software reliability

    International Nuclear Information System (INIS)

    Park, J. K; Sung, T. Y.; Eom, H. S.; Jeong, H. S.; Park, J. H.; Kang, H. G.; Lee, K. Y.; Park, J. K.

    2000-04-01

    To develop the methodology for evaluating the software reliability included in digital instrumentation and control system (I and C), many kinds of methodologies/techniques that have been proposed from the software reliability engineering fuel are analyzed to identify the strong and week points of them. According to analysis results, methodologies/techniques that can be directly applied for the evaluation of the software reliability are not exist. Thus additional researches to combine the most appropriate methodologies/techniques from existing ones would be needed to evaluate the software reliability. (author)

  10. Intra- and interobserver reliability of quantitative ultrasound measurement of the plantar fascia.

    Science.gov (United States)

    Rathleff, Michael Skovdal; Moelgaard, Carsten; Lykkegaard Olesen, Jens

    2011-01-01

    To determine intra- and interobserver reliability and measurement precision of sonographic assessment of plantar fascia thickness when using one, the mean of two, or the mean of three measurements. Two experienced observers scanned 20 healthy subjects twice with 60 minutes between test and retest. A GE LOGIQe ultrasound scanner was used in the study. The built-in software in the scanner was used to measure the thickness of the plantar fascia (PF). Reliability was calculated using intraclass correlation coefficient (ICC) and limits of agreement (LOA). Intraobserver reliability (ICC) using one measurement was 0.50 for one observer and 0.52 for the other, and using the mean of three measurements intraobserver reliability increased up to 0.77 and 0.67, respectively. Interobserver reliability (ICC) when using one measurement was 0.62 and increased to 0.82 when using the average of three measurements. LOA showed that when using the average of three measurements, LOA decreased to 0.6 mm, corresponding to 17.5% of the mean thickness of the PF. The results showed that reliability increases when using the mean of three measurements compared with one. Limits of agreement based on intratester reliability shows that changes in thickness that are larger than 0.6 mm can be considered actual changes in thickness and not a result of measurement error. Copyright © 2011 Wiley Periodicals, Inc.

  11. Reliable LC-MS quantitative glycomics using iGlycoMab stable isotope labeled glycans as internal standards.

    Science.gov (United States)

    Zhou, Shiyue; Tello, Nadia; Harvey, Alex; Boyes, Barry; Orlando, Ron; Mechref, Yehia

    2016-06-01

    Glycans have numerous functions in various biological processes and participate in the progress of diseases. Reliable quantitative glycomic profiling techniques could contribute to the understanding of the biological functions of glycans, and lead to the discovery of potential glycan biomarkers for diseases. Although LC-MS is a powerful analytical tool for quantitative glycomics, the variation of ionization efficiency and MS intensity bias are influencing quantitation reliability. Internal standards can be utilized for glycomic quantitation by MS-based methods to reduce variability. In this study, we used stable isotope labeled IgG2b monoclonal antibody, iGlycoMab, as an internal standard to reduce potential for errors and to reduce variabililty due to sample digestion, derivatization, and fluctuation of nanoESI efficiency in the LC-MS analysis of permethylated N-glycans released from model glycoproteins, human blood serum, and breast cancer cell line. We observed an unanticipated degradation of isotope labeled glycans, tracked a source of such degradation, and optimized a sample preparation protocol to minimize degradation of the internal standard glycans. All results indicated the effectiveness of using iGlycoMab to minimize errors originating from sample handling and instruments. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Enhancement of the reliability of automated ultrasonic inspections using tools of quantitative NDT

    International Nuclear Information System (INIS)

    Kappes, W.; Baehr, W.; Kroening, M.; Schmitz, V.

    1994-01-01

    To achieve reliable test results from automated ultrasonic inspection of safety related components, optimization and integral consideration of the various inspection stages - inspection planning, inspection performance and evaluation of results - are indispensable. For this purpose, a large potential of methods is available: advanced measurement techniques, mathematical-numerical modelling processes, artificial intelligence tools, data bases and CAD systems. The potential inherent in these methods to enhance inspection reliability is outlined by way of different applications. (orig.) [de

  13. Water-soluble upper GI based on clinical findings is reliable to detect anastomotic leaks after laparoscopic gastric bypass.

    Science.gov (United States)

    Katasani, V G; Leeth, R R; Tishler, D S; Leath, T D; Roy, B P; Canon, C L; Vickers, S M; Clements, R H

    2005-11-01

    Anastomotic leak after laparoscopic Roux-en-Y gastric bypass (LGB) is a major complication that must be recognized and treated early for best results. There is controversy in the literature regarding the reliability of upper GI series (UGI) in diagnosing leaks. LGB was performed in patients meeting NIH criteria for the surgical treatment of morbid obesity. All leaks identified at the time of surgery were repaired with suture and retested. Drains were placed at the surgeon's discretion. Postoperatively, UGI was performed by an experienced radiologist if there was a clinical suspicion of leak. From September 2001 until October 2004, a total of 553 patients (age 40.4 +/- 9.2 years, BMI 48.6 +/- 7.2) underwent LGB at UAB. Seventy-eight per cent (431 of 553) of patients had no clinical evidence suggesting anastomotic leak and were managed expectantly. Twenty-two per cent (122 of 553) of patients met at least one inclusion criteria for leak and underwent UGI. Four of 122 patients (3.2%) had a leak, two from anastomosis and two from the perforation of the stapled end of the Roux limb. No patient returned to the operating room without a positive UGI. High clinical suspicion and selectively performed UGI based on clinical evidence is reliable in detecting leaks.

  14. Reliable reference miRNAs for quantitative gene expression analysis of stress responses in Caenorhabditis elegans

    DEFF Research Database (Denmark)

    Kagias, Konstantinos; Podolska, Agnieszka; Pocock, Roger David John

    2014-01-01

    Quantitative real-time PCR (qPCR) has become the "gold standard" for measuring expression levels of individual miRNAs. However, little is known about the validity of reference miRNAs, the improper use of which can result in misleading interpretation of data.......Quantitative real-time PCR (qPCR) has become the "gold standard" for measuring expression levels of individual miRNAs. However, little is known about the validity of reference miRNAs, the improper use of which can result in misleading interpretation of data....

  15. Quantitative gait analysis under dual-task in older people with mild cognitive impairment: a reliability study

    Directory of Open Access Journals (Sweden)

    Gutmanis Iris

    2009-09-01

    Full Text Available Abstract Background Reliability of quantitative gait assessment while dual-tasking (walking while doing a secondary task such as talking in people with cognitive impairment is unknown. Dual-tasking gait assessment is becoming highly important for mobility research with older adults since better reflects their performance in the basic activities of daily living. Our purpose was to establish the test-retest reliability of assessing quantitative gait variables using an electronic walkway in older adults with mild cognitive impairment (MCI under single and dual-task conditions. Methods The gait performance of 11 elderly individuals with MCI was evaluated using an electronic walkway (GAITRite® System in two sessions, one week apart. Six gait parameters (gait velocity, step length, stride length, step time, stride time, and double support time were assessed under two conditions: single-task (sG: usual walking and dual-task (dG: counting backwards from 100 while walking. Test-retest reliability was determined using intra-class correlation coefficient (ICC. Gait variability was measured using coefficient of variation (CoV. Results Eleven participants (average age = 76.6 years, SD = 7.3 were assessed. They were high functioning (Clinical Dementia Rating Score = 0.5 with a mean Mini-Mental Status Exam (MMSE score of 28 (SD = 1.56, and a mean Montreal Cognitive Assessment (MoCA score of 22.8 (SD = 1.23. Under dual-task conditions, mean gait velocity (GV decreased significantly (sGV = 119.11 ± 20.20 cm/s; dGV = 110.88 ± 19.76 cm/s; p = 0.005. Additionally, under dual-task conditions, higher gait variability was found on stride time, step time, and double support time. Test-retest reliability was high (ICC>0.85 for the six parameters evaluated under both conditions. Conclusion In older people with MCI, variability of time-related gait parameters increased with dual-tasking suggesting cognitive control of gait performance. Assessment of quantitative gait

  16. A Quantitative Risk Analysis Framework for Evaluating and Monitoring Operational Reliability of Cloud Computing

    Science.gov (United States)

    Islam, Muhammad Faysal

    2013-01-01

    Cloud computing offers the advantage of on-demand, reliable and cost efficient computing solutions without the capital investment and management resources to build and maintain in-house data centers and network infrastructures. Scalability of cloud solutions enable consumers to upgrade or downsize their services as needed. In a cloud environment,…

  17. The Hidden Value of Narrative Comments for Assessment: A Quantitative Reliability Analysis of Qualitative Data.

    Science.gov (United States)

    Ginsburg, Shiphra; van der Vleuten, Cees P M; Eva, Kevin W

    2017-11-01

    In-training evaluation reports (ITERs) are ubiquitous in internal medicine (IM) residency. Written comments can provide a rich data source, yet are often overlooked. This study determined the reliability of using variable amounts of commentary to discriminate between residents. ITER comments from two cohorts of PGY-1s in IM at the University of Toronto (graduating 2010 and 2011; n = 46-48) were put into sets containing 15 to 16 residents. Parallel sets were created: one with comments from the full year and one with comments from only the first three assessments. Each set was rank-ordered by four internists external to the program between April 2014 and May 2015 (n = 24). Generalizability analyses and a decision study were performed. For the full year of comments, reliability coefficients averaged across four rankers were G = 0.85 and G = 0.91 for the two cohorts. For a single ranker, G = 0.60 and G = 0.73. Using only the first three assessments, reliabilities remained high at G = 0.66 and G = 0.60 for a single ranker. In a decision study, if two internists ranked the first three assessments, reliability would be G = 0.80 and G = 0.75 for the two cohorts. Using written comments to discriminate between residents can be extremely reliable even after only several reports are collected. This suggests a way to identify residents early on who may require attention. These findings contribute evidence to support the validity argument for using qualitative data for assessment.

  18. Are commercial 99m Tc-DTPA preparations reliable for quantitation of renal function

    International Nuclear Information System (INIS)

    Jeghers, O.; Kinthaert, J.; Georges, B.; Van Gansbeke, B.; Piepsz, A.; Ham, H.R.

    1983-01-01

    Bad labeling and stability of 99m-Tc-DTPA preparations were found on several occasions, resulting in important artefacts in quantitative renal studies. Further studies are needed in order to understand the origin of these inconstant findings. Repeated quality control on Tc-99m-DTPA preparations are mandatory

  19. 76 FR 28819 - NUREG/CR-XXXX, Development of Quantitative Software Reliability Models for Digital Protection...

    Science.gov (United States)

    2011-05-18

    ... NUCLEAR REGULATORY COMMISSION [NRC-2011-0109] NUREG/CR-XXXX, Development of Quantitative Software...: The Nuclear Regulatory Commission has issued for public comment a document entitled: NUREG/CR-XXXX...-XXXX is available electronically under ADAMS Accession Number ML111020087. Federal Rulemaking Web Site...

  20. A Novel HPLC Method for the Concurrent Analysis and Quantitation of Seven Water-Soluble Vitamins in Biological Fluids (Plasma and Urine: A Validation Study and Application

    Directory of Open Access Journals (Sweden)

    Margherita Grotzkyj Giorgi

    2012-01-01

    Full Text Available An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B1, B2, B5, B6, B9, B12 in biological matrices (plasma and urine. Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males. Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%.

  1. A novel HPLC method for the concurrent analysis and quantitation of seven water-soluble vitamins in biological fluids (plasma and urine): a validation study and application.

    Science.gov (United States)

    Giorgi, Margherita Grotzkyj; Howland, Kevin; Martin, Colin; Bonner, Adrian B

    2012-01-01

    An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B(1), B(2), B(5), B(6), B(9), B(12)) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were vitamins. Recovery percentages ranged from 93% to 100%.

  2. Magnetic particle separation technique: a reliable and simple tool for RIA/IRMA and quantitative PCR assay

    International Nuclear Information System (INIS)

    Shen Rongsen; Shen Decun

    1998-01-01

    Five types of magnetic particles without or with aldehyde, amino and carboxyl functional groups, respectively were used to immobilize first or second antibody by three models, i. e. physical adsorption, chemical coupling and immuno-affinity, forming four types of magnetic particle antibodies. The second antibody immobilized on polyacrolein magnetic particles through aldehyde functional groups and the first antibodies immobilized on carboxylic polystyrene magnetic particles through carboxyl functional groups were recommended to apply to RIAs and/or IRMAs. Streptavidin immobilized on commercial magnetic particles through amino functional groups was successfully applied to separating specific PCR product for quantification of human cytomegalovirus. In the paper typical data on reliability of these magnetic particle ligands were reported and simplicity of the magnetic particle separation technique was discussed. The results showed that the technique was a reliable and simple tool for RIA/IRMA and quantitative PCR assay. (author)

  3. Qualification Testing Versus Quantitative Reliability Testing of PV - Gaining Confidence in a Rapidly Changing Technology: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Repins, Ingrid L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hacke, Peter L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jordan, Dirk [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kempe, Michael D [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Whitfield, Kent [Underwriters Laboratories; Phillips, Nancy [DuPont; Sample, Tony [European Commission; Monokroussos, Christos [TUV Rheinland; Hsi, Edward [Swiss RE; Wohlgemuth, John [PowerMark Corporation; Seidel, Peter [First Solar; Jahn, Ulrike [TUV Rheinland; Tanahashi, Tadanori [National Institute of Advanced Industrial Science and Technology; Chen, Yingnan [China General Certification Center; Jaeckel, Bengt [Underwriters Laboratories; Yamamichi, Masaaki [RTS Corporation

    2017-10-05

    Continued growth of PV system deployment would be enhanced by quantitative, low-uncertainty predictions of the degradation and failure rates of PV modules and systems. The intended product lifetime (decades) far exceeds the product development cycle (months), limiting our ability to reduce the uncertainty of the predictions for this rapidly changing technology. Yet, business decisions (setting insurance rates, analyzing return on investment, etc.) require quantitative risk assessment. Moving toward more quantitative assessments requires consideration of many factors, including the intended application, consequence of a possible failure, variability in the manufacturing, installation, and operation, as well as uncertainty in the measured acceleration factors, which provide the basis for predictions based on accelerated tests. As the industry matures, it is useful to periodically assess the overall strategy for standards development and prioritization of research to provide a technical basis both for the standards and the analysis related to the application of those. To this end, this paper suggests a tiered approach to creating risk assessments. Recent and planned potential improvements in international standards are also summarized.

  4. Reliable gene expression analysis by reverse transcription-quantitative PCR: reporting and minimizing the uncertainty in data accuracy.

    Science.gov (United States)

    Remans, Tony; Keunen, Els; Bex, Geert Jan; Smeets, Karen; Vangronsveld, Jaco; Cuypers, Ann

    2014-10-01

    Reverse transcription-quantitative PCR (RT-qPCR) has been widely adopted to measure differences in mRNA levels; however, biological and technical variation strongly affects the accuracy of the reported differences. RT-qPCR specialists have warned that, unless researchers minimize this variability, they may report inaccurate differences and draw incorrect biological conclusions. The Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines describe procedures for conducting and reporting RT-qPCR experiments. The MIQE guidelines enable others to judge the reliability of reported results; however, a recent literature survey found low adherence to these guidelines. Additionally, even experiments that use appropriate procedures remain subject to individual variation that statistical methods cannot correct. For example, since ideal reference genes do not exist, the widely used method of normalizing RT-qPCR data to reference genes generates background noise that affects the accuracy of measured changes in mRNA levels. However, current RT-qPCR data reporting styles ignore this source of variation. In this commentary, we direct researchers to appropriate procedures, outline a method to present the remaining uncertainty in data accuracy, and propose an intuitive way to select reference genes to minimize uncertainty. Reporting the uncertainty in data accuracy also serves for quality assessment, enabling researchers and peer reviewers to confidently evaluate the reliability of gene expression data. © 2014 American Society of Plant Biologists. All rights reserved.

  5. A quantitative assessment of alkaptonuria: testing the reliability of two disease severity scoring systems.

    Science.gov (United States)

    Cox, Trevor F; Ranganath, Lakshminarayan

    2011-12-01

    Alkaptonuria (AKU) is due to excessive homogentisic acid accumulation in body fluids due to lack of enzyme homogentisate dioxygenase leading in turn to varied clinical manifestations mainly by a process of conversion of HGA to a polymeric melanin-like pigment known as ochronosis. A potential treatment, a drug called nitisinone, to decrease formation of HGA is available. However, successful demonstration of its efficacy in modifying the natural history of AKU requires an effective quantitative assessment tool. We have described two potential tools that could be used to quantitate disease burden in AKU. One tool describes scoring the clinical features that includes clinical assessments, investigations and questionnaires in 15 patients with AKU. The second tool describes a scoring system that only includes items obtained from questionnaires used in 44 people with AKU. Statistical analyses were carried out on the two patient datasets to assess the AKU tools; these included the calculation of Chronbach's alpha, multidimensional scaling and simple linear regression analysis. The conclusion was that there was good evidence that the tools could be adopted as AKU assessment tools, but perhaps with further refinement before being used in the practical setting of a clinical trial.

  6. Relative validity and reliability of a quantitative food frequency questionnaire for adults in Guam

    Directory of Open Access Journals (Sweden)

    Rachael T. Leon Guerrero

    2015-05-01

    Full Text Available Background: Guam is a US territory in the western Pacific with a diverse population that includes understudied ethnic groups such as Chamorros and Filipinos. A food frequency questionnaire (FFQ to estimate dietary intake was needed to facilitate studies of diet and health among adults living in Guam. Objective: To develop and validate an FFQ to assess dietary intake over a 1-year period among adult Guam residents. Design: A three-part study was conducted: 1 an initial cross-sectional study using 24-h recalls to identify a food and beverage list for the FFQ and resulting in a final FFQ containing 142 food and drink items; 2 to test reliability, 56 different individuals completed the FFQ twice; and 3 to test relative validity, self-administered FFQs and up to 2 days of food record data from an additional 109 individuals were collected, and daily nutrient intake from the two methods was compared. Results: The reliability of the FFQ was very good (ρ range=0.65–0.75, and the relative validity of the FFQ was good for women (median Spearman's correlation [ρ] between instruments of 0.45 across 20 nutrients and an interquartile range [IQR] of 0.42–0.58 and generally adequate for men (median ρ=0.31, IQR=0.23–0.55. Validity was also good for Chamorros (median ρ=0.47, IQR=0.38–0.53 and generally adequate for Filipinos (median ρ=0.42, IQR=0.20–0.62. Correlations after energy adjustment were lower (overall median ρ=0.20, IQR=0.14–0.26. Conclusions: The FFQ can be used to rank nutrient intake for adults in Guam and may be helpful in the analysis of relationships between diet and chronic disease in Guam.

  7. Quantitative assessment of probability of failing safely for the safety instrumented system using reliability block diagram method

    International Nuclear Information System (INIS)

    Jin, Jianghong; Pang, Lei; Zhao, Shoutang; Hu, Bin

    2015-01-01

    Highlights: • Models of PFS for SIS were established by using the reliability block diagram. • The more accurate calculation of PFS for SIS can be acquired by using SL. • Degraded operation of complex SIS does not affect the availability of SIS. • The safe undetected failure is the largest contribution to the PFS of SIS. - Abstract: The spurious trip of safety instrumented system (SIS) brings great economic losses to production. How to ensure the safety instrumented system is reliable and available has been put on the schedule. But the existing models on spurious trip rate (STR) or probability of failing safely (PFS) are too simplified and not accurate, in-depth studies of availability to obtain more accurate PFS for SIS are required. Based on the analysis of factors that influence the PFS for the SIS, using reliability block diagram method (RBD), the quantitative study of PFS for the SIS is carried out, and gives some application examples. The results show that, the common cause failure will increase the PFS; degraded operation does not affect the availability of the SIS; if the equipment was tested and repaired one by one, the unavailability of the SIS can be ignored; the corresponding occurrence time of independent safe undetected failure should be the system lifecycle (SL) rather than the proof test interval and the independent safe undetected failure is the largest contribution to the PFS for the SIS

  8. The search for reliable aqueous solubility (Sw) and octanol-water partition coefficient (Kow) data for hydrophobic organic compounds; DDT and DDE as a case study

    Science.gov (United States)

    Pontolillo, James; Eganhouse, R.P.

    2001-01-01

    The accurate determination of an organic contaminant?s physico-chemical properties is essential for predicting its environmental impact and fate. Approximately 700 publications (1944?2001) were reviewed and all known aqueous solubilities (Sw) and octanol-water partition coefficients (Kow) for the organochlorine pesticide, DDT, and its persistent metabolite, DDE were compiled and examined. Two problems are evident with the available database: 1) egregious errors in reporting data and references, and 2) poor data quality and/or inadequate documentation of procedures. The published literature (particularly the collative literature such as compilation articles and handbooks) is characterized by a preponderance of unnecessary data duplication. Numerous data and citation errors are also present in the literature. The percentage of original Sw and Kow data in compilations has decreased with time, and in the most recent publications (1994?97) it composes only 6?26 percent of the reported data. The variability of original DDT/DDE Sw and Kow data spans 2?4 orders of magnitude, and there is little indication that the uncertainty in these properties has declined over the last 5 decades. A criteria-based evaluation of DDT/DDE Sw and Kow data sources shows that 95?100 percent of the database literature is of poor or unevaluatable quality. The accuracy and reliability of the vast majority of the data are unknown due to inadequate documentation of the methods of determination used by the authors. [For example, estimates of precision have been reported for only 20 percent of experimental Sw data and 10 percent of experimental Kow data.] Computational methods for estimating these parameters have been increasingly substituted for direct or indirect experimental determination despite the fact that the data used for model development and validation may be of unknown reliability. Because of the prevalence of errors, the lack of methodological documentation, and unsatisfactory data

  9. Total protein analysis as a reliable loading control for quantitative fluorescent Western blotting.

    Directory of Open Access Journals (Sweden)

    Samantha L Eaton

    Full Text Available Western blotting has been a key technique for determining the relative expression of proteins within complex biological samples since the first publications in 1979. Recent developments in sensitive fluorescent labels, with truly quantifiable linear ranges and greater limits of detection, have allowed biologists to probe tissue specific pathways and processes with higher resolution than ever before. However, the application of quantitative Western blotting (QWB to a range of healthy tissues and those from degenerative models has highlighted a problem with significant consequences for quantitative protein analysis: how can researchers conduct comparative expression analyses when many of the commonly used reference proteins (e.g. loading controls are differentially expressed? Here we demonstrate that common controls, including actin and tubulin, are differentially expressed in tissues from a wide range of animal models of neurodegeneration. We highlight the prevalence of such alterations through examination of published "-omics" data, and demonstrate similar responses in sensitive QWB experiments. For example, QWB analysis of spinal cord from a murine model of Spinal Muscular Atrophy using an Odyssey scanner revealed that beta-actin expression was decreased by 19.3±2% compared to healthy littermate controls. Thus, normalising QWB data to β-actin in these circumstances could result in 'skewing' of all data by ∼20%. We further demonstrate that differential expression of commonly used loading controls was not restricted to the nervous system, but was also detectable across multiple tissues, including bone, fat and internal organs. Moreover, expression of these "control" proteins was not consistent between different portions of the same tissue, highlighting the importance of careful and consistent tissue sampling for QWB experiments. Finally, having illustrated the problem of selecting appropriate single protein loading controls, we demonstrate

  10. Intra-rater reliability of motor unit number estimation and quantitative motor unit analysis in subjects with amyotrophic lateral sclerosis.

    Science.gov (United States)

    Ives, Colleen T; Doherty, Timothy J

    2014-01-01

    To assess the intra-rater reliability of decomposition-enhanced spike-triggered averaging (DE-STA) motor unit number estimation (MUNE) and quantitative motor unit potential analysis in the upper trapezius (UT) and biceps brachii (BB) of subjects with amyotrophic lateral sclerosis (ALS) and to compare the results from the UT to control data. Patients diagnosed with clinically probable or definite ALS completed the experimental protocol twice with the same evaluator for the UT (n=10) and BB (n=9). Intra-rater reliability for the UT was good for the maximum compound muscle action potential (CMAP) (ICC=0.88), mean surface-detected motor unit potential (S-MUP) (ICC=0.87) and MUNE (ICC=0.88), and for the BB was moderate for maximum CMAP (ICC=0.61), and excellent for mean S-MUP (ICC=0.94) and MUNE (ICC=0.93). A significant difference between tests was found for UT MUNE. Comparing subjects with ALS to control subjects, UT maximum CMAP (p<0.01) and MUNE (p<0.001) values were significantly lower, and mean S-MUP values significantly greater (p<0.05) in subjects with ALS. This study has demonstrated the ability of the DE-STA MUNE technique to collect highly reliable data from two separate muscle groups and to detect the underlying pathophysiology of the disease. This was the first study to examine the reliability of this technique in subjects with ALS, and demonstrates its potential for future use as an outcome measure in ALS clinical trials and studies of ALS disease severity and natural history. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Comparison of the THERP quantitative tables with the human reliability analysis techniques of second generation

    International Nuclear Information System (INIS)

    Alvarenga, Marco Antonio Bayout; Fonseca, Renato Alves

    2009-01-01

    The methodology THERP is classified as a Human Reliability Analysis (HRA) technique of first generation and its emergence was an important initial step for the development of HRA techniques in the industry. Due to the fact of being a first generation technique, THERP quantification tables of human errors are based on a taxonomy that does not take into account the human errors mechanisms. Concerning the three cognitive levels in the Rasmussen framework for the cognitive information processing in human beings, THERP deals in most cases with errors that happen in the perceptual-motor level (stimulus-response). In the rules level, this technique can work better using the time dependent probabilities curves of diagnosis errors, obtained in nuclear power plants simulators. Nevertheless, this is done without processing any error mechanisms. Another deficiency is the fact that the performance shaping factors are in limited number. Furthermore, the influences (predictable or not) of operational context, arising from operational deviations of the most probable (in terms of occurrence probabilities) standard scenarios beside the consequent operational tendencies (operator actions) are not estimated. This work makes a critical analysis of these deficiencies and it points out possible solutions in order to modify the THERP tables, seeking a realistic quantification, that does not underestimate or overestimate the human errors probabilities when applying the HRA techniques to nuclear power plants. The critical analysis is accomplished through a qualitative comparison between THERP, a HRA technique of first generation, with CREAM, as well as ATHEANA, which are HRA techniques of second generation. (author)

  12. Comparison of macro and micro Raman measurement for reliable quantitative analysis of pharmaceutical polymorphs.

    Science.gov (United States)

    Paiva, Eduardo M; da Silva, Vitor H; Poppi, Ronei J; Pereira, Claudete F; Rohwedder, Jarbas J R

    2018-05-12

    This work reports on the use of micro- and macro-Raman measurements for quantification of mebendazole (MBZ) polymorphs A, B, and C in mixtures. Three Raman spectrophotometers were studied with a laser spot size of 3, 80 and 100 μm and spectral resolutions of 3.9, 9 and 4 cm -1 , respectively. The samples studied were ternary mixtures varying the MBZ polymorphs A and C from 0 to 100% and polymorph B from 0 to 30%. Partial Least Squares (PLS) regression models were developed using the pre-processing spectra (2nd derivative) of the ternary mixtures. The best performance was obtained when the macro-Raman configuration was applied, obtaining RMSEP values of 1.68%, 1.24% and 2.03% w/w for polymorphs A, B, and C, respectively. In general, micro-Raman presented worst results for MBZ polymorphs prediction because the spectra obtained with this configuration does not represent the bulk proportion of mixtures, which have different particle morphologies and sizes. In addition, the influence of these particle features on micro-Raman measurements was also studied. Finally, the results demonstrated that reliable analytical quantifying of MBZ polymorphs can be reached using a laser with wider area illuminated, thus enabling acquisition of more reproductive and representative spectra of the mixtures. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Comparison of the THERP quantitative tables with the human reliability analysis techniques of second generation

    Energy Technology Data Exchange (ETDEWEB)

    Alvarenga, Marco Antonio Bayout; Fonseca, Renato Alves [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)], e-mail: bayout@cnen.gov.br, e-mail: rfonseca@cnen.gov.br

    2009-07-01

    The methodology THERP is classified as a Human Reliability Analysis (HRA) technique of first generation and its emergence was an important initial step for the development of HRA techniques in the industry. Due to the fact of being a first generation technique, THERP quantification tables of human errors are based on a taxonomy that does not take into account the human errors mechanisms. Concerning the three cognitive levels in the Rasmussen framework for the cognitive information processing in human beings, THERP deals in most cases with errors that happen in the perceptual-motor level (stimulus-response). In the rules level, this technique can work better using the time dependent probabilities curves of diagnosis errors, obtained in nuclear power plants simulators. Nevertheless, this is done without processing any error mechanisms. Another deficiency is the fact that the performance shaping factors are in limited number. Furthermore, the influences (predictable or not) of operational context, arising from operational deviations of the most probable (in terms of occurrence probabilities) standard scenarios beside the consequent operational tendencies (operator actions) are not estimated. This work makes a critical analysis of these deficiencies and it points out possible solutions in order to modify the THERP tables, seeking a realistic quantification, that does not underestimate or overestimate the human errors probabilities when applying the HRA techniques to nuclear power plants. The critical analysis is accomplished through a qualitative comparison between THERP, a HRA technique of first generation, with CREAM, as well as ATHEANA, which are HRA techniques of second generation. (author)

  14. Raman spectroscopy of human skin: looking for a quantitative algorithm to reliably estimate human age

    Science.gov (United States)

    Pezzotti, Giuseppe; Boffelli, Marco; Miyamori, Daisuke; Uemura, Takeshi; Marunaka, Yoshinori; Zhu, Wenliang; Ikegaya, Hiroshi

    2015-06-01

    The possibility of examining soft tissues by Raman spectroscopy is challenged in an attempt to probe human age for the changes in biochemical composition of skin that accompany aging. We present a proof-of-concept report for explicating the biophysical links between vibrational characteristics and the specific compositional and chemical changes associated with aging. The actual existence of such links is then phenomenologically proved. In an attempt to foster the basics for a quantitative use of Raman spectroscopy in assessing aging from human skin samples, a precise spectral deconvolution is performed as a function of donors' ages on five cadaveric samples, which emphasizes the physical significance and the morphological modifications of the Raman bands. The outputs suggest the presence of spectral markers for age identification from skin samples. Some of them appeared as authentic "biological clocks" for the apparent exactness with which they are related to age. Our spectroscopic approach yields clear compositional information of protein folding and crystallization of lipid structures, which can lead to a precise identification of age from infants to adults. Once statistically validated, these parameters might be used to link vibrational aspects at the molecular scale for practical forensic purposes.

  15. Selection and validation of a set of reliable reference genes for quantitative sod gene expression analysis in C. elegans

    Directory of Open Access Journals (Sweden)

    Vandesompele Jo

    2008-01-01

    Full Text Available Abstract Background In the nematode Caenorhabditis elegans the conserved Ins/IGF-1 signaling pathway regulates many biological processes including life span, stress response, dauer diapause and metabolism. Detection of differentially expressed genes may contribute to a better understanding of the mechanism by which the Ins/IGF-1 signaling pathway regulates these processes. Appropriate normalization is an essential prerequisite for obtaining accurate and reproducible quantification of gene expression levels. The aim of this study was to establish a reliable set of reference genes for gene expression analysis in C. elegans. Results Real-time quantitative PCR was used to evaluate the expression stability of 12 candidate reference genes (act-1, ama-1, cdc-42, csq-1, eif-3.C, mdh-1, gpd-2, pmp-3, tba-1, Y45F10D.4, rgs-6 and unc-16 in wild-type, three Ins/IGF-1 pathway mutants, dauers and L3 stage larvae. After geNorm analysis, cdc-42, pmp-3 and Y45F10D.4 showed the most stable expression pattern and were used to normalize 5 sod expression levels. Significant differences in mRNA levels were observed for sod-1 and sod-3 in daf-2 relative to wild-type animals, whereas in dauers sod-1, sod-3, sod-4 and sod-5 are differentially expressed relative to third stage larvae. Conclusion Our findings emphasize the importance of accurate normalization using stably expressed reference genes. The methodology used in this study is generally applicable to reliably quantify gene expression levels in the nematode C. elegans using quantitative PCR.

  16. A fast and reliable readout method for quantitative analysis of surface-enhanced Raman scattering nanoprobes on chip surface

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Hyejin; Jeong, Sinyoung; Ko, Eunbyeol; Jeong, Dae Hong, E-mail: yslee@snu.ac.kr, E-mail: debobkr@gmail.com, E-mail: jeongdh@snu.ac.kr [Department of Chemistry Education, Seoul National University, Seoul 151-742 (Korea, Republic of); Kang, Homan [Interdisciplinary Program in Nano-Science and Technology, Seoul National University, Seoul 151-742 (Korea, Republic of); Lee, Yoon-Sik, E-mail: yslee@snu.ac.kr, E-mail: debobkr@gmail.com, E-mail: jeongdh@snu.ac.kr [Interdisciplinary Program in Nano-Science and Technology, Seoul National University, Seoul 151-742 (Korea, Republic of); School of Chemical and Biological Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Lee, Ho-Young, E-mail: yslee@snu.ac.kr, E-mail: debobkr@gmail.com, E-mail: jeongdh@snu.ac.kr [Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of)

    2015-05-15

    Surface-enhanced Raman scattering techniques have been widely used for bioanalysis due to its high sensitivity and multiplex capacity. However, the point-scanning method using a micro-Raman system, which is the most common method in the literature, has a disadvantage of extremely long measurement time for on-chip immunoassay adopting a large chip area of approximately 1-mm scale and confocal beam point of ca. 1-μm size. Alternative methods such as sampled spot scan with high confocality and large-area scan method with enlarged field of view and low confocality have been utilized in order to minimize the measurement time practically. In this study, we analyzed the two methods in respect of signal-to-noise ratio and sampling-led signal fluctuations to obtain insights into a fast and reliable readout strategy. On this basis, we proposed a methodology for fast and reliable quantitative measurement of the whole chip area. The proposed method adopted a raster scan covering a full area of 100 μm × 100 μm region as a proof-of-concept experiment while accumulating signals in the CCD detector for single spectrum per frame. One single scan with 10 s over 100 μm × 100 μm area yielded much higher sensitivity compared to sampled spot scanning measurements and no signal fluctuations attributed to sampled spot scan. This readout method is able to serve as one of key technologies that will bring quantitative multiplexed detection and analysis into practice.

  17. Reliability and short-term intra-individual variability of telomere length measurement using monochrome multiplexing quantitative PCR.

    Directory of Open Access Journals (Sweden)

    Sangmi Kim

    Full Text Available Studies examining the association between telomere length and cancer risk have often relied on measurement of telomere length from a single blood draw using a real-time PCR technique. We examined the reliability of telomere length measurement using sequential samples collected over a 9-month period.Relative telomere length in peripheral blood was estimated using a single tube monochrome multiplex quantitative PCR assay in blood DNA samples from 27 non-pregnant adult women (aged 35 to 74 years collected in 7 visits over a 9-month period. A linear mixed model was used to estimate the components of variance for telomere length measurements attributed to variation among women and variation between time points within women. Mean telomere length measurement at any single visit was not significantly different from the average of 7 visits. Plates had a significant systematic influence on telomere length measurements, although measurements between different plates were highly correlated. After controlling for plate effects, 64% of the remaining variance was estimated to be accounted for by variance due to subject. Variance explained by time of visit within a subject was minor, contributing 5% of the remaining variance.Our data demonstrate good short-term reliability of telomere length measurement using blood from a single draw. However, the existence of technical variability, particularly plate effects, reinforces the need for technical replicates and balancing of case and control samples across plates.

  18. reliability reliability

    African Journals Online (AJOL)

    eobe

    Corresponding author, Tel: +234-703. RELIABILITY .... V , , given by the code of practice. However, checks must .... an optimization procedure over the failure domain F corresponding .... of Concrete Members based on Utility Theory,. Technical ...

  19. A guide on the elicitation of expert knowledge in constructing BBN for quantitative reliability assessment of safety critical software

    International Nuclear Information System (INIS)

    Eom, H. S.; Kang, H. G.; Chang, S. C.; Ha, J. J.

    2003-08-01

    This report describes the methodology which could elicit probabilistic representation from the experts' knowledge or qualitative data. It is necessary to elicit expert's knowledge while we quantitatively assess the reliability of safety critical software using Bayesian Belief Nets(BBNs). Especially in composing the node probability table and in making out the input data for BBN model, experts' qualitative judgment or qualitative data should be converted into probabilistic representation. This conversion process is vulnerable to bias or error. The purpose of the report is to provide the guideline to avoid the occurrence of this kinds of bias/error or to eliminate them which is included in the existing data prepared by experts. The contents of the report are: o The types and the explanation of bias and error The types of bias and error which might be occur in the process of eliciting the expert's knowledge. o The procedure of expert's judgment elicitation. The process and techniques to avoid bias and error in eliciting the expert's judgments. o The examples of expert's knowledge appeared in the BBNs The examples of expert's knowledge (probability values) appeared in the BBNs for assessing the safety of digital system

  20. Selection of reliable reference genes for quantitative real-time PCR in human T cells and neutrophils

    Directory of Open Access Journals (Sweden)

    Ledderose Carola

    2011-10-01

    Full Text Available Abstract Background The choice of reliable reference genes is a prerequisite for valid results when analyzing gene expression with real-time quantitative PCR (qPCR. This method is frequently applied to study gene expression patterns in immune cells, yet a thorough validation of potential reference genes is still lacking for most leukocyte subtypes and most models of their in vitro stimulation. In the current study, we evaluated the expression stability of common reference genes in two widely used cell culture models-anti-CD3/CD28 activated T cells and lipopolysaccharide stimulated neutrophils-as well as in unselected untreated leukocytes. Results The mRNA expression of 17 (T cells, 7 (neutrophils or 8 (unselected leukocytes potential reference genes was quantified by reverse transcription qPCR, and a ranking of the preselected candidate genes according to their expression stability was calculated using the programs NormFinder, geNorm and BestKeeper. IPO8, RPL13A, TBP and SDHA were identified as suitable reference genes in T cells. TBP, ACTB and SDHA were stably expressed in neutrophils. TBP and SDHA were also the most stable genes in untreated total blood leukocytes. The critical impact of reference gene selection on the estimated target gene expression is demonstrated for IL-2 and FIH expression in T cells. Conclusions The study provides a shortlist of suitable reference genes for normalization of gene expression data in unstimulated and stimulated T cells, unstimulated and stimulated neutrophils and in unselected leukocytes.

  1. Identification and evaluation of reliable reference genes for quantitative real-time PCR analysis in tea plant (Camellia sinensis (L.) O. Kuntze)

    Science.gov (United States)

    Quantitative real-time polymerase chain reaction (qRT-PCR) is a commonly used technique for measuring gene expression levels due to its simplicity, specificity, and sensitivity. Reliable reference selection for the accurate quantification of gene expression under various experimental conditions is a...

  2. The use and reliability of SymNose for quantitative measurement of the nose and lip in unilateral cleft lip and palate patients.

    Science.gov (United States)

    Mosmuller, David; Tan, Robin; Mulder, Frans; Bachour, Yara; de Vet, Henrica; Don Griot, Peter

    2016-10-01

    It is essential to have a reliable assessment method in order to compare the results of cleft lip and palate surgery. In this study the computer-based program SymNose, a method for quantitative assessment of the nose and lip, will be assessed on usability and reliability. The symmetry of the nose and lip was measured twice in 50 six-year-old complete and incomplete unilateral cleft lip and palate patients by four observers. For the frontal view the asymmetry level of the nose and upper lip were evaluated and for the basal view the asymmetry level of the nose and nostrils were evaluated. A mean inter-observer reliability when tracing each image once or twice was 0.70 and 0.75, respectively. Tracing the photographs with 2 observers and 4 observers gave a mean inter-observer score of 0.86 and 0.92, respectively. The mean intra-observer reliability varied between 0.80 and 0.84. SymNose is a practical and reliable tool for the retrospective assessment of large caseloads of 2D photographs of cleft patients for research purposes. Moderate to high single inter-observer reliability was found. For future research with SymNose reliable outcomes can be achieved by using the average outcomes of single tracings of two observers. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Reliability of a novel, semi-quantitative scale for classification of structural brain magnetic resonance imaging in children with cerebral palsy.

    Science.gov (United States)

    Fiori, Simona; Cioni, Giovanni; Klingels, Katrjin; Ortibus, Els; Van Gestel, Leen; Rose, Stephen; Boyd, Roslyn N; Feys, Hilde; Guzzetta, Andrea

    2014-09-01

    To describe the development of a novel rating scale for classification of brain structural magnetic resonance imaging (MRI) in children with cerebral palsy (CP) and to assess its interrater and intrarater reliability. The scale consists of three sections. Section 1 contains descriptive information about the patient and MRI. Section 2 contains the graphical template of brain hemispheres onto which the lesion is transposed. Section 3 contains the scoring system for the quantitative analysis of the lesion characteristics, grouped into different global scores and subscores that assess separately side, regions, and depth. A larger interrater and intrarater reliability study was performed in 34 children with CP (22 males, 12 females; mean age at scan of 9 y 5 mo [SD 3 y 3 mo], range 4 y-16 y 11 mo; Gross Motor Function Classification System level I, [n=22], II [n=10], and level III [n=2]). Very high interrater and intrarater reliability of the total score was found with indices above 0.87. Reliability coefficients of the lobar and hemispheric subscores ranged between 0.53 and 0.95. Global scores for hemispheres, basal ganglia, brain stem, and corpus callosum showed reliability coefficients above 0.65. This study presents the first visual, semi-quantitative scale for classification of brain structural MRI in children with CP. The high degree of reliability of the scale supports its potential application for investigating the relationship between brain structure and function and examining treatment response according to brain lesion severity in children with CP. © 2014 Mac Keith Press.

  4. Quantitative developments in the cognitive reliability and error analysis method (CREAM) for the assessment of human performance

    International Nuclear Information System (INIS)

    Marseguerra, Marzio; Zio, Enrico; Librizzi, Massimo

    2006-01-01

    The current 'second generation' approaches in human reliability analysis focus their attention on the contextual conditions under which a given action is performed rather than on the notion of inherent human error probabilities, as was done in the earlier 'first generation' techniques. Among the 'second generation' methods, this paper considers the Cognitive Reliability and Error Analysis Method (CREAM) and proposes some developments with respect to a systematic procedure for computing probabilities of action failure. The starting point for the quantification is a previously introduced fuzzy version of the CREAM paradigm which is here further extended to include uncertainty on the qualification of the conditions under which the action is performed and to account for the fact that the effects of the common performance conditions (CPCs) on performance reliability may not all be equal. By the proposed approach, the probability of action failure is estimated by rating the performance conditions in terms of their effect on the action

  5. Plutonium solubilities

    International Nuclear Information System (INIS)

    Puigdomnech, I.; Bruno, J.

    1991-02-01

    Thermochemical data has been selected for plutonium oxide, hydroxide, carbonate and phosphate equilibria. Equilibrium constants have been evaluated in the temperature range 0 to 300 degrees C at a pressure of 1 bar to T≤100 degrees C and at the steam saturated pressure at higher temperatures. Measured solubilities of plutonium that are reported in the literature for laboratory experiments have been collected. Solubility data on oxides, hydroxides, carbonates and phosphates have been selected. No solubility data were found at temperatures higher than 60 degrees C. The literature solubility data have been compared with plutonium solubilities calculated with the EQ3/6 geochemical modelling programs, using the selected thermodynamic data for plutonium. (authors)

  6. Quantitative and Qualitative Responses to Topical Cold in Healthy Caucasians Show Variance between Individuals but High Test-Retest Reliability.

    Directory of Open Access Journals (Sweden)

    Penny Moss

    Full Text Available Increased sensitivity to cold may be a predictor of persistent pain, but cold pain threshold is often viewed as unreliable. This study aimed to determine the within-subject reliability and between-subject variance of cold response, measured comprehensively as cold pain threshold plus pain intensity and sensation quality at threshold. A test-retest design was used over three sessions, one day apart. Response to cold was assessed at four sites (thenar eminence, volar forearm, tibialis anterior, plantar foot. Cold pain threshold was measured using a Medoc thermode and standard method of limits. Intensity of pain at threshold was rated using a 10cm visual analogue scale. Quality of sensation at threshold was quantified with indices calculated from subjects' selection of descriptors from a standard McGill Pain Questionnaire. Within-subject reliability for each measure was calculated with intra-class correlation coefficients and between-subject variance was evaluated as group coefficient of variation percentage (CV%. Gender and site comparisons were also made. Forty-five healthy adults participated: 20 male, 25 female; mean age 29 (range 18-56 years. All measures at all four test sites showed high within-subject reliability: cold pain thresholds r = 0.92-0.95; pain rating r = 0.93-0.97; McGill pain quality indices r = 0.87-0.85. In contrast, all measures showed wide between-subject variance (CV% between 51.4% and 92.5%. Upper limb sites were consistently more sensitive than lower limb sites, but equally reliable. Females showed elevated cold pain thresholds, although similar pain intensity and quality to males. Females were also more reliable and showed lower variance for all measures. Thus, although there was clear population variation, response to cold for healthy individuals was found to be highly reliable, whether measured as pain threshold, pain intensity or sensation quality. A comprehensive approach to cold response testing therefore may add

  7. Quantitative and Qualitative Responses to Topical Cold in Healthy Caucasians Show Variance between Individuals but High Test-Retest Reliability.

    Science.gov (United States)

    Moss, Penny; Whitnell, Jasmine; Wright, Anthony

    2016-01-01

    Increased sensitivity to cold may be a predictor of persistent pain, but cold pain threshold is often viewed as unreliable. This study aimed to determine the within-subject reliability and between-subject variance of cold response, measured comprehensively as cold pain threshold plus pain intensity and sensation quality at threshold. A test-retest design was used over three sessions, one day apart. Response to cold was assessed at four sites (thenar eminence, volar forearm, tibialis anterior, plantar foot). Cold pain threshold was measured using a Medoc thermode and standard method of limits. Intensity of pain at threshold was rated using a 10cm visual analogue scale. Quality of sensation at threshold was quantified with indices calculated from subjects' selection of descriptors from a standard McGill Pain Questionnaire. Within-subject reliability for each measure was calculated with intra-class correlation coefficients and between-subject variance was evaluated as group coefficient of variation percentage (CV%). Gender and site comparisons were also made. Forty-five healthy adults participated: 20 male, 25 female; mean age 29 (range 18-56) years. All measures at all four test sites showed high within-subject reliability: cold pain thresholds r = 0.92-0.95; pain rating r = 0.93-0.97; McGill pain quality indices r = 0.87-0.85. In contrast, all measures showed wide between-subject variance (CV% between 51.4% and 92.5%). Upper limb sites were consistently more sensitive than lower limb sites, but equally reliable. Females showed elevated cold pain thresholds, although similar pain intensity and quality to males. Females were also more reliable and showed lower variance for all measures. Thus, although there was clear population variation, response to cold for healthy individuals was found to be highly reliable, whether measured as pain threshold, pain intensity or sensation quality. A comprehensive approach to cold response testing therefore may add validity and

  8. [Methods quantitative for determination of water-soluble vitamins in premixes and fortified food products by micellar electrokinetic chromatography on short end of the capillary].

    Science.gov (United States)

    Bogachuk, M N; Bessonov, V V; Perederiaev, O I

    2011-01-01

    It was purposed new technique by micellar electrokinetic chromatography on short end of the capillary (capillary electrophoresis system Agilent 3D CE, DAD, quartz capillary HPCE stndrd cap 56 cm, 50 microm, 50 mM borate buffer pH=9,3, 100 mM sodium dodecil sulfate) for simultaneous determination of water-soluble vitamins (B1, B2, B6, B12, PP, B5, B9, C, B8) in fortified food products and premixes. It was observed on 6 samples of vitamin premixes and 28 samples of fortified food products using this technique. Our findings are consistent with the results of research on certain vitamins, conducted by other methods. The developed technique can be used in analysis of water-soluble vitamins in premixes and fortified food products.

  9. rpb2 is a reliable reference gene for quantitative gene expression analysis in the dermatophyte Trichophyton rubrum.

    Science.gov (United States)

    Jacob, Tiago R; Peres, Nalu T A; Persinoti, Gabriela F; Silva, Larissa G; Mazucato, Mendelson; Rossi, Antonio; Martinez-Rossi, Nilce M

    2012-05-01

    The selection of reference genes used for data normalization to quantify gene expression by real-time PCR amplifications (qRT-PCR) is crucial for the accuracy of this technique. In spite of this, little information regarding such genes for qRT-PCR is available for gene expression analyses in pathogenic fungi. Thus, we investigated the suitability of eight candidate reference genes in isolates of the human dermatophyte Trichophyton rubrum subjected to several environmental challenges, such as drug exposure, interaction with human nail and skin, and heat stress. The stability of these genes was determined by geNorm, NormFinder and Best-Keeper programs. The gene with the most stable expression in the majority of the conditions tested was rpb2 (DNA-dependent RNA polymerase II), which was validated in three T. rubrum strains. Moreover, the combination of rpb2 and chs1 (chitin synthase) genes provided for the most reliable qRT-PCR data normalization in T. rubrum under a broad range of biological conditions. To the best of our knowledge this is the first report on the selection of reference genes for qRT-PCR data normalization in dermatophytes and the results of these studies should permit further analysis of gene expression under several experimental conditions, with improved accuracy and reliability.

  10. PI-RADS version 2: quantitative analysis aids reliable interpretation of diffusion-weighted imaging for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Yoon; Jung, Dae Chul; Oh, Young Taik [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Seoul (Korea, Republic of); Shin, Su-Jin [Yonsei University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Hanyang University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Cho, Nam Hoon [Yonsei University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Choi, Young Deuk; Rha, Koon Ho; Hong, Sung Joon [Yonsei University College of Medicine, Department of Urology, Seoul (Korea, Republic of)

    2017-07-15

    To determine whether apparent diffusion coefficient (ADC) ratio aids reliable interpretation of diffusion-weighted imaging (DWI) for prostate cancer (PCa). Seventy-six consecutive patients with PCa who underwent DWI and surgery were included. Based on pathologic tumour location, two readers independently performed DWI scoring according to the revised Prostate Imaging Reporting and Data System (PI-RADSv2). ADC ratios of benign to cancerous prostatic tissue were then measured independently and compared between cases showing concordant and discordant DWI scores ≥4. Area under the curve (AUC) and threshold of ADC ratio were analyzed for DWI scores ≥4. The rate of inter-reader disagreement for DWI score ≥4 was 11.8% (9/76). ADC ratios were higher in concordant vs. discordant DWI scores ≥4 (median, 1.7 vs. 1.1-1.2; p < 0.001). For DWI scores ≥4, the AUCs of ADC ratios were 0.970 for reader 1 and 0.959 for reader 2. In patients with an ADC ratio >1.3, the rate of inter-reader disagreement for DWI score ≥4 decreased to 5.9-6.0%. An ADC ratio >1.3 yielded 100% (reader 1, 54/54; reader 2, 51/51) positive predictive value for clinically significant cancer. ADC ratios may be useful for reliable interpretation of DWI score ≥4 in PI-RADSv2. (orig.)

  11. Contribution to a quantitative assessment model for reliability-based metrics of electronic and programmable safety-related functions

    International Nuclear Information System (INIS)

    Hamidi, K.

    2005-10-01

    The use of fault-tolerant EP architectures has induced growing constraints, whose influence on reliability-based performance metrics is no more negligible. To face up the growing influence of simultaneous failure, this thesis proposes, for safety-related functions, a new-trend assessment method of reliability, based on a better taking into account of time-aspect. This report introduces the concept of information and uses it to interpret the failure modes of safety-related function as the direct result of the initiation and propagation of erroneous information until the actuator-level. The main idea is to distinguish the apparition and disappearance of erroneous states, which could be defined as intrinsically dependent of HW-characteristic and maintenance policies, and their possible activation, constrained through architectural choices, leading to the failure of safety-related function. This approach is based on a low level on deterministic SED models of the architecture and use non homogeneous Markov chains to depict the time-evolution of probabilities of errors. (author)

  12. Development and application of novelty pretreatment method for the concurrent quantitation of eleven water-soluble B vitamins in ultrafiltrates after renal replacement therapy.

    Science.gov (United States)

    Wirkus, Dorota; Jakubus, Aleksandra; Owczuk, Radosław; Stepnowski, Piotr; Paszkiewicz, Monika

    2017-02-01

    Continous renal replacement therapy (CRRT) is particularly recommended for septic shock patients in intensive care units. The CRRT technique used most frequently is high volume continuous veno-venous haemofiltration. It provides a high rate of clearance of uremic toxins and inflammatory cytokines. However, it should also be taken into account that substances important for homeostasis may be concurrently unintentionally removed. Accordingly, water-soluble vitamins can be removed during continuous renal replacement therapy, and the estimate of the loss is critical to ensure appropriate supplementation. The aim of this work was to develop a simple methodology for a purification step prior to the LC-MS/MS determination of water-soluble vitamins in ultrafiltrate samples. For this purpose, two types of resin and a mix of resins were used as sorbents for the purification step. Moreover, parameters such as the amount of resin and the extraction time were optimized. The LC-MS/MS method was developed and validated for final determination of 11 vitamins. The results demonstrated the high purification capability of DEAE Sephadex resin with recoveries between 65 and 101% for water-soluble vitamins from ultrafiltrate samples. An optimized method was applied to assess the loss of B-group vitamins in patients after 24h of renal replacement therapy. The loss of vitamins B2, B6 pyridoxamine, B6 pyridoxal, B7, B1, and B5 in ultrafiltrates was similar in all patients. In the native ultrafiltrates, vitamins B6 pyridoxine, B9 and B12 were not detected. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Quantitative contrast enhanced ultrasound of the liver for time intensity curves-Reliability and potential sources of errors.

    Science.gov (United States)

    Ignee, Andre; Jedrejczyk, Maciej; Schuessler, Gudrun; Jakubowski, Wieslaw; Dietrich, Christoph F

    2010-01-01

    Time intensity curves for real-time contrast enhanced low MI ultrasound is a promising technique since it adds objective data to the more subjective conventional contrast enhanced technique. Current developments showed that the amount of uptake in modern targeted therapy strategies correlates with therapy response. Nevertheless no basic research has been done concerning the reliability and validity of the method. Videos sequences of 31 consecutive patients for at least 60s were recorded. Parameters analysed: area under the curve, maximum intensity, mean transit time, perfusion index, time to peak, rise time. The influence of depth, lateral shift as well as size and shape of the region of interest was analysed. The parameters time to peak and rise time showed a good stability in different depths. Overall there was a variation >50% for all other parameters. Mean transit time, time to peak and rise time were stable from 3 to 10cm depths, whereas all other parameters showed only satisfying results at 4-6cm. Time to peak and rise time were stable as well against lateral shifting whereas all other parameters had again variations over 50%. Size and shape of the region of interest did not influence the results. (1) It is important to compare regions of interest, e.g. in a tumour vs. representative parenchyma in the same depths. (2) Time intensity curves should not be analysed in a depth of less than 4cm. (3) The parameters area under the curve, perfusion index and maximum intensity should not be analysed in a depth more than 6cm. (4) Size and shape of a region of interest in liver parenchyma do not affect time intensity curves. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  14. Quantitative contrast enhanced ultrasound of the liver for time intensity curves-Reliability and potential sources of errors

    Energy Technology Data Exchange (ETDEWEB)

    Ignee, Andre [Department of Internal Medicine and Diagnostic Imaging, Caritas Hospital, Uhlandstr. 7, 97990 Bad Mergentheim (Germany)], E-mail: andre.ignee@gmx.de; Jedrejczyk, Maciej [Department of Diagnostic Imaging, 2nd Division of Medical Faculty, Medical University, Ul. Kondratowicza 8, 03-242 Warsaw (Poland)], E-mail: mjedrzejczyk@interia.pl; Schuessler, Gudrun [Department of Internal Medicine and Diagnostic Imaging, Caritas Hospital, Uhlandstr. 7, 97990 Bad Mergentheim (Germany)], E-mail: gudrunschuessler@gmx.de; Jakubowski, Wieslaw [Department of Diagnostic Imaging, 2nd Division of Medical Faculty, Medical University, Ul. Kondratowicza 8, 03-242 Warsaw (Poland)], E-mail: ewajbmd@go2.pl; Dietrich, Christoph F. [Department of Internal Medicine and Diagnostic Imaging, Caritas Hospital, Uhlandstr. 7, 97990 Bad Mergentheim (Germany)], E-mail: christoph.dietrich@ckbm.de

    2010-01-15

    Introduction: Time intensity curves for real-time contrast enhanced low MI ultrasound is a promising technique since it adds objective data to the more subjective conventional contrast enhanced technique. Current developments showed that the amount of uptake in modern targeted therapy strategies correlates with therapy response. Nevertheless no basic research has been done concerning the reliability and validity of the method. Patients and methods: Videos sequences of 31 consecutive patients for at least 60 s were recorded. Parameters analysed: area under the curve, maximum intensity, mean transit time, perfusion index, time to peak, rise time. The influence of depth, lateral shift as well as size and shape of the region of interest was analysed. Results: The parameters time to peak and rise time showed a good stability in different depths. Overall there was a variation >50% for all other parameters. Mean transit time, time to peak and rise time were stable from 3 to 10 cm depths, whereas all other parameters showed only satisfying results at 4-6 cm. Time to peak and rise time were stable as well against lateral shifting whereas all other parameters had again variations over 50%. Size and shape of the region of interest did not influence the results. Discussion: (1) It is important to compare regions of interest, e.g. in a tumour vs. representative parenchyma in the same depths. (2) Time intensity curves should not be analysed in a depth of less than 4 cm. (3) The parameters area under the curve, perfusion index and maximum intensity should not be analysed in a depth more than 6 cm. (4) Size and shape of a region of interest in liver parenchyma do not affect time intensity curves.

  15. Quantitative contrast enhanced ultrasound of the liver for time intensity curves-Reliability and potential sources of errors

    International Nuclear Information System (INIS)

    Ignee, Andre; Jedrejczyk, Maciej; Schuessler, Gudrun; Jakubowski, Wieslaw; Dietrich, Christoph F.

    2010-01-01

    Introduction: Time intensity curves for real-time contrast enhanced low MI ultrasound is a promising technique since it adds objective data to the more subjective conventional contrast enhanced technique. Current developments showed that the amount of uptake in modern targeted therapy strategies correlates with therapy response. Nevertheless no basic research has been done concerning the reliability and validity of the method. Patients and methods: Videos sequences of 31 consecutive patients for at least 60 s were recorded. Parameters analysed: area under the curve, maximum intensity, mean transit time, perfusion index, time to peak, rise time. The influence of depth, lateral shift as well as size and shape of the region of interest was analysed. Results: The parameters time to peak and rise time showed a good stability in different depths. Overall there was a variation >50% for all other parameters. Mean transit time, time to peak and rise time were stable from 3 to 10 cm depths, whereas all other parameters showed only satisfying results at 4-6 cm. Time to peak and rise time were stable as well against lateral shifting whereas all other parameters had again variations over 50%. Size and shape of the region of interest did not influence the results. Discussion: (1) It is important to compare regions of interest, e.g. in a tumour vs. representative parenchyma in the same depths. (2) Time intensity curves should not be analysed in a depth of less than 4 cm. (3) The parameters area under the curve, perfusion index and maximum intensity should not be analysed in a depth more than 6 cm. (4) Size and shape of a region of interest in liver parenchyma do not affect time intensity curves.

  16. Test-retest and interobserver reliability of quantitative sensory testing according to the protocol of the German Research Network on Neuropathic Pain (DFNS): a multi-centre study.

    Science.gov (United States)

    Geber, Christian; Klein, Thomas; Azad, Shahnaz; Birklein, Frank; Gierthmühlen, Janne; Huge, Volker; Lauchart, Meike; Nitzsche, Dorothee; Stengel, Maike; Valet, Michael; Baron, Ralf; Maier, Christoph; Tölle, Thomas; Treede, Rolf-Detlef

    2011-03-01

    Quantitative sensory testing (QST) is an instrument to assess positive and negative sensory signs, helping to identify mechanisms underlying pathologic pain conditions. In this study, we evaluated the test-retest reliability (TR-R) and the interobserver reliability (IO-R) of QST in patients with sensory disturbances of different etiologies. In 4 centres, 60 patients (37 male and 23 female, 56.4±1.9years) with lesions or diseases of the somatosensory system were included. QST comprised 13 parameters including detection and pain thresholds for thermal and mechanical stimuli. QST was performed in the clinically most affected test area and a less or unaffected control area in a morning and an afternoon session on 2 consecutive days by examiner pairs (4 QSTs/patient). For both, TR-R and IO-R, there were high correlations (r=0.80-0.93) at the affected test area, except for wind-up ratio (TR-R: r=0.67; IO-R: r=0.56) and paradoxical heat sensations (TR-R: r=0.35; IO-R: r=0.44). Mean IO-R (r=0.83, 31% unexplained variance) was slightly lower than TR-R (r=0.86, 26% unexplained variance, Ptest area (TR-R: r=0.86; IO-R: r=0.83) than in the control area (TR-R: r=0.79; IO-R: r=0.71, each Preliability of QST. We conclude that standardized QST performed by trained examiners is a valuable diagnostic instrument with good test-retest and interobserver reliability within 2days. With standardized training, observer bias is much lower than random variance. Quantitative sensory testing performed by trained examiners is a valuable diagnostic instrument with good interobserver and test-retest reliability for use in patients with sensory disturbances of different etiologies to help identify mechanisms of neuropathic and non-neuropathic pain. Copyright © 2010 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  17. Quantitative LC–MS for water-soluble heterocyclic amines in fine aerosols (PM2.5) at Duke Forest, USA

    Science.gov (United States)

    In this study, a quantitative liquid chromatography-mass spectrometry (LC-MS) technique capable of measuring the concentrations of heterocyclic nitrogen compounds in ambient fine aerosols (PM2.5) has been developed. Quadrupole time-of-flight (Q-TOF) MS technology is used to provi...

  18. Students’ misconceptions on solubility equilibrium

    Science.gov (United States)

    Setiowati, H.; Utomo, S. B.; Ashadi

    2018-05-01

    This study investigated the students’ misconceptions of the solubility equilibrium. The participants of the study consisted of 164 students who were in the science class of second year high school. Instrument used is two-tier diagnostic test consisting of 15 items. Responses were marked and coded into four categories: understanding, misconception, understand little without misconception, and not understanding. Semi-structured interviews were carried out with 45 students according to their written responses which reflected different perspectives, to obtain a more elaborated source of data. Data collected from multiple methods were analyzed qualitatively and quantitatively. Based on the data analysis showed that the students misconceptions in all areas in solubility equilibrium. They had more misconceptions such as in the relation of solubility and solubility product, common-ion effect and pH in solubility, and precipitation concept.

  19. Selection of Reliable Reference Genes for Gene Expression Studies of a Promising Oilseed Crop, Plukenetia volubilis, by Real-Time Quantitative PCR

    Directory of Open Access Journals (Sweden)

    Longjian Niu

    2015-06-01

    Full Text Available Real-time quantitative PCR (RT-qPCR is a reliable and widely used method for gene expression analysis. The accuracy of the determination of a target gene expression level by RT-qPCR demands the use of appropriate reference genes to normalize the mRNA levels among different samples. However, suitable reference genes for RT-qPCR have not been identified in Sacha inchi (Plukenetia volubilis, a promising oilseed crop known for its polyunsaturated fatty acid (PUFA-rich seeds. In this study, using RT-qPCR, twelve candidate reference genes were examined in seedlings and adult plants, during flower and seed development and for the entire growth cycle of Sacha inchi. Four statistical algorithms (delta cycle threshold (ΔCt, BestKeeper, geNorm, and NormFinder were used to assess the expression stabilities of the candidate genes. The results showed that ubiquitin-conjugating enzyme (UCE, actin (ACT and phospholipase A22 (PLA were the most stable genes in Sacha inchi seedlings. For roots, stems, leaves, flowers, and seeds from adult plants, 30S ribosomal protein S13 (RPS13, cyclophilin (CYC and elongation factor-1alpha (EF1α were recommended as reference genes for RT-qPCR. During the development of reproductive organs, PLA, ACT and UCE were the optimal reference genes for flower development, whereas UCE, RPS13 and RNA polymerase II subunit (RPII were optimal for seed development. Considering the entire growth cycle of Sacha inchi, UCE, ACT and EF1α were sufficient for the purpose of normalization. Our results provide useful guidelines for the selection of reliable reference genes for the normalization of RT-qPCR data for seedlings and adult plants, for reproductive organs, and for the entire growth cycle of Sacha inchi.

  20. Selection of Reliable Reference Genes for Gene Expression Studies of a Promising Oilseed Crop, Plukenetia volubilis, by Real-Time Quantitative PCR

    Science.gov (United States)

    Niu, Longjian; Tao, Yan-Bin; Chen, Mao-Sheng; Fu, Qiantang; Li, Chaoqiong; Dong, Yuling; Wang, Xiulan; He, Huiying; Xu, Zeng-Fu

    2015-01-01

    Real-time quantitative PCR (RT-qPCR) is a reliable and widely used method for gene expression analysis. The accuracy of the determination of a target gene expression level by RT-qPCR demands the use of appropriate reference genes to normalize the mRNA levels among different samples. However, suitable reference genes for RT-qPCR have not been identified in Sacha inchi (Plukenetia volubilis), a promising oilseed crop known for its polyunsaturated fatty acid (PUFA)-rich seeds. In this study, using RT-qPCR, twelve candidate reference genes were examined in seedlings and adult plants, during flower and seed development and for the entire growth cycle of Sacha inchi. Four statistical algorithms (delta cycle threshold (ΔCt), BestKeeper, geNorm, and NormFinder) were used to assess the expression stabilities of the candidate genes. The results showed that ubiquitin-conjugating enzyme (UCE), actin (ACT) and phospholipase A22 (PLA) were the most stable genes in Sacha inchi seedlings. For roots, stems, leaves, flowers, and seeds from adult plants, 30S ribosomal protein S13 (RPS13), cyclophilin (CYC) and elongation factor-1alpha (EF1α) were recommended as reference genes for RT-qPCR. During the development of reproductive organs, PLA, ACT and UCE were the optimal reference genes for flower development, whereas UCE, RPS13 and RNA polymerase II subunit (RPII) were optimal for seed development. Considering the entire growth cycle of Sacha inchi, UCE, ACT and EF1α were sufficient for the purpose of normalization. Our results provide useful guidelines for the selection of reliable reference genes for the normalization of RT-qPCR data for seedlings and adult plants, for reproductive organs, and for the entire growth cycle of Sacha inchi. PMID:26047338

  1. Secondary dentine as a sole parameter for age estimation: Comparison and reliability of qualitative and quantitative methods among North Western adult Indians

    Directory of Open Access Journals (Sweden)

    Jasbir Arora

    2016-06-01

    Full Text Available The indestructible nature of teeth against most of the environmental abuses makes its use in disaster victim identification (DVI. The present study has been undertaken to examine the reliability of Gustafson’s qualitative method and Kedici’s quantitative method of measuring secondary dentine for age estimation among North Western adult Indians. 196 (M = 85; F = 111 single rooted teeth were collected from the Department of Oral Health Sciences, PGIMER, Chandigarh. Ground sections were prepared and the amount of secondary dentine formed was scored qualitatively according to Gustafson’s (0–3 scoring system (method 1 and quantitatively following Kedici’s micrometric measurement method (method 2. Out of 196 teeth 180 samples (M = 80; F = 100 were found to be suitable for measuring secondary dentine following Kedici’s method. Absolute mean error of age was calculated by both methodologies. Results clearly showed that in pooled data, method 1 gave an error of ±10.4 years whereas method 2 exhibited an error of approximately ±13 years. A statistically significant difference was noted in absolute mean error of age between two methods of measuring secondary dentine for age estimation. Further, it was also revealed that teeth extracted for periodontal reasons severely decreased the accuracy of Kedici’s method however, the disease had no effect while estimating age by Gustafson’s method. No significant gender differences were noted in the absolute mean error of age by both methods which suggest that there is no need to separate data on the basis of gender.

  2. How stable are quantitative sensory testing measurements over time? Report on 10-week reliability and agreement of results in healthy volunteers

    Directory of Open Access Journals (Sweden)

    Nothnagel H

    2017-08-01

    Full Text Available Helen Nothnagel,1,2,* Christian Puta,1,3,* Thomas Lehmann,4 Philipp Baumbach,5 Martha B Menard,6,7 Brunhild Gabriel,1 Holger H W Gabriel,1 Thomas Weiss,8 Frauke Musial2 1Department of Sports Medicine and Health Promotion, Friedrich Schiller University, Jena, Germany; 2Department of Community Medicine, National Research Center in Complementary and Alternative Medicine, UiT, The Arctic University of Norway, Tromsø, Norway; 3Center for Interdisciplinary Prevention of Diseases Related to Professional Activities, 4Department of Medical Statistics, Computer Sciences and Documentation, Friedrich Schiller University, 5Department of Anesthesiology and Intensive Care Medicine, University Hospital Jena, Germany; 6Crocker Institute, Kiawah Island, SC, 7School of Integrative Medicine and Health Sciences, Saybrook University, Oakland, CA, USA; 8Department of Biological and Clinical Psychology, Friedrich Schiller University, Jena, Germany *These authors contributed equally to this work Background: Quantitative sensory testing (QST is a diagnostic tool for the assessment of the somatosensory system. To establish QST as an outcome measure for clinical trials, the question of how similar the measurements are over time is crucial. Therefore, long-term reliability and limits of agreement of the standardized QST protocol of the German Research Network on Neuropathic Pain were tested. Methods: QST on the lower back and hand dorsum (dominant hand were assessed twice in 22 healthy volunteers (10 males and 12 females; mean age: 46.6±13.0 years, with sessions separated by 10.0±2.9 weeks. All measurements were performed by one investigator. To investigate long-term reliability and agreement of QST, differences between the two measurements, correlation coefficients, intraclass correlation coefficients (ICCs, Bland–Altman plots (limits of agreement, and standard error of measurement were used. Results: Most parameters of the QST were reliable over 10 weeks in

  3. Solubility Products of M(II) - Carbonates

    International Nuclear Information System (INIS)

    Grauer, Rolf; Berner, Urs

    1999-01-01

    Many solubility data for M(II) carbonates commonly compiled in tables are contradictory and sometimes obviously wrong. The quality of such data has been evaluated based on the original publications and reliable solubility constants have been selected for the carbonates of Mn, Fe, Co, Ni, Cu, Zn, Cd and Pb with the help of cross-comparisons. (author)

  4. Reliability engineering

    International Nuclear Information System (INIS)

    Lee, Chi Woo; Kim, Sun Jin; Lee, Seung Woo; Jeong, Sang Yeong

    1993-08-01

    This book start what is reliability? such as origin of reliability problems, definition of reliability and reliability and use of reliability. It also deals with probability and calculation of reliability, reliability function and failure rate, probability distribution of reliability, assumption of MTBF, process of probability distribution, down time, maintainability and availability, break down maintenance and preventive maintenance design of reliability, design of reliability for prediction and statistics, reliability test, reliability data and design and management of reliability.

  5. Development of core technology for KNGR system design; development of quantitative reliability evaluation methodologies of KNGR digital I and C components

    Energy Technology Data Exchange (ETDEWEB)

    Seong, Poong Hyun; Choi, Jong Gyun; Kim, Ung Soo; Kim, Jong Hyun; Kim, Man Cheol; Lee, Seung Jun; Lee, Young Je; Ha, Jun Soo [Korea Advanced Institute of Science and Technology, Taejeon (Korea)

    2002-03-01

    For the digital systems to be applied to the nuclear industry, which has its unique conservertive to safety, reliability assessment of digital systems is a prerequisite. But, because digital systems show different failure modes from compared to existing analog systems, the existing reliability assessment method cannot be applied to digital systems. It means that a new reliability assessment method for digital systems should be developed. The goal of this study is development of reliability assessment method for digital systems on board level and related software tool. To achieve the goal, we have conducted researches on development of a database for hardware components for digital I and C systems, development of a reliability assessment model for the reliability prediction of digital systems on board level, and the applicability to KNGR digital I and C systems. We developed a database for reliability assessment of digital hardware components, a reliability assessment method for digital systems with consideration of software and hardware together, and a software tool for the reliability assessment of digital systems, which is named as RelPredic. We plan to apply the results of this study to the reliability assessment of digital systems in KNGR digital I and C systems. 13 refs., 71 figs., 31 tabs. (Author)

  6. Selection and validation of a set of reliable reference genes for quantitative RT-PCR studies in the brain of the Cephalopod Mollusc Octopus vulgaris

    Directory of Open Access Journals (Sweden)

    Biffali Elio

    2009-07-01

    Full Text Available Abstract Background Quantitative real-time polymerase chain reaction (RT-qPCR is valuable for studying the molecular events underlying physiological and behavioral phenomena. Normalization of real-time PCR data is critical for a reliable mRNA quantification. Here we identify reference genes to be utilized in RT-qPCR experiments to normalize and monitor the expression of target genes in the brain of the cephalopod mollusc Octopus vulgaris, an invertebrate. Such an approach is novel for this taxon and of advantage in future experiments given the complexity of the behavioral repertoire of this species when compared with its relatively simple neural organization. Results We chose 16S, and 18S rRNA, actB, EEF1A, tubA and ubi as candidate reference genes (housekeeping genes, HKG. The expression of 16S and 18S was highly variable and did not meet the requirements of candidate HKG. The expression of the other genes was almost stable and uniform among samples. We analyzed the expression of HKG into two different set of animals using tissues taken from the central nervous system (brain parts and mantle (here considered as control tissue by BestKeeper, geNorm and NormFinder. We found that HKG expressions differed considerably with respect to brain area and octopus samples in an HKG-specific manner. However, when the mantle is treated as control tissue and the entire central nervous system is considered, NormFinder revealed tubA and ubi as the most suitable HKG pair. These two genes were utilized to evaluate the relative expression of the genes FoxP, creb, dat and TH in O. vulgaris. Conclusion We analyzed the expression profiles of some genes here identified for O. vulgaris by applying RT-qPCR analysis for the first time in cephalopods. We validated candidate reference genes and found the expression of ubi and tubA to be the most appropriate to evaluate the expression of target genes in the brain of different octopuses. Our results also underline the

  7. The reliability of the quantitative timed up and go test (QTUG) measured over five consecutive days under single and dual-task conditions in community dwelling older adults.

    Science.gov (United States)

    Smith, Erin; Walsh, Lorcan; Doyle, Julie; Greene, Barry; Blake, Catherine

    2016-01-01

    The timed up and go (TUG) test is a commonly used assessment in older people with variations including the addition of a motor or cognitive dual-task, however in high functioning older adults it is more difficult to assess change. The quantified TUG (QTUG) uses inertial sensors to detect test and gait parameters during the test. If it is to be used in the longitudinal assessment of older adults, it is important that we know which parameters are reliable and under which conditions. This study aims to examine the relative reliability of the QTUG over five consecutive days under single, motor and cognitive dual-task conditions. Twelve community dwelling older adults (10 females, mean age 74.17 (3.88)) performed the QTUG under three conditions for five consecutive days. The relative reliability of each of the gait parameters was assessed using intra-class correlation coefficient (ICC 3,1) and standard error of measurement (SEM). Five of the measures demonstrated excellent reliability (ICC>0.70) under all three conditions (time to complete test, walk time, number of gait cycles, number of steps and return from turn time). Measures of variability and turn derived parameters demonstrated weak reliability under all three conditions (ICC=0.05-0.49). For the most reliable parameters under single-task conditions, the addition of a cognitive task resulted in a reduction in reliability suggesting caution when interpreting results under these conditions. Certain sensor derived parameters during the QTUG test may provide an additional resource in the longitudinal assessment of older people and earlier identification of falls risk. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Solubility Products of M(II) - Carbonates

    Energy Technology Data Exchange (ETDEWEB)

    Grauer, Rolf; Berner, Urs [ed.

    1999-01-01

    Many solubility data for M(II) carbonates commonly compiled in tables are contradictory and sometimes obviously wrong. The quality of such data has been evaluated based on the original publications and reliable solubility constants have been selected for the carbonates of Mn, Fe, Co, Ni, Cu, Zn, Cd and Pb with the help of cross-comparisons. (author) translated from a PSI internal report written in German in 1994 (TM-44-94-05). 5 figs., 1 tab., 68 refs.

  9. Gas solubilities widespread applications

    CERN Document Server

    Gerrard, William

    1980-01-01

    Gas Solubilities: Widespread Applications discusses several topics concerning the various applications of gas solubilities. The first chapter of the book reviews Henr's law, while the second chapter covers the effect of temperature on gas solubility. The third chapter discusses the various gases used by Horiuti, and the following chapters evaluate the data on sulfur dioxide, chlorine data, and solubility data for hydrogen sulfide. Chapter 7 concerns itself with solubility of radon, thoron, and actinon. Chapter 8 tackles the solubilities of diborane and the gaseous hydrides of groups IV, V, and

  10. Pure Phase Solubility Limits: LANL

    International Nuclear Information System (INIS)

    C. Stockman

    2001-01-01

    , complex stability constants, and redox potentials for radionuclides in different oxidation states, form the underlying database to be used for those calculations. The potentially low solubilities of many radionuclides in natural waters constitute the first barrier for their migration from the repository into the environment. Evaluation of this effect requires a knowledge of the site-specific water chemistry and the expected spatial and temporal ranges of its variability. Quantitative determinations of radionuclide solubility in waters within the range of chemistry must be made. Speciation and molecular complexation must be ascertained to interpret and apply solubility results. The solubilities thus determined can be used to assess the effectiveness of solubility in limiting radionuclide migration. These solubilities can also be used to evaluate the effectiveness of other retardation processes expected to occur once dissolution of the source material and migration begin. Understanding the solubility behavior of radionuclides will assist in designing valuable sorption experiments that must be conducted below the solubility limit since only soluble species participate in surface reactions and sorption processes. The present strategy for radionuclide solubility tasks has been to provide a solubility model from bulk-experiments that attempt to bracket the estimate made for this Analysis and Modeling Report (AMR) of water conditions on site. The long-term goal must be to develop a thermodynamic database for solution speciation and solid-state determination as a prerequisite for transport calculations and interpretation of empirical solubility data. The model has to be self-consistent and tested against known solubility studies in order to predict radionuclide solubilities over the continuous distribution ranges of potential water compositions for performance assessment of the site. Solubility studies upper limits for radionuclide concentrations in natural waters. The

  11. Pure Phase Solubility Limits: LANL

    Energy Technology Data Exchange (ETDEWEB)

    C. Stockman

    2001-01-26

    products, complex stability constants, and redox potentials for radionuclides in different oxidation states, form the underlying database to be used for those calculations. The potentially low solubilities of many radionuclides in natural waters constitute the first barrier for their migration from the repository into the environment. Evaluation of this effect requires a knowledge of the site-specific water chemistry and the expected spatial and temporal ranges of its variability. Quantitative determinations of radionuclide solubility in waters within the range of chemistry must be made. Speciation and molecular complexation must be ascertained to interpret and apply solubility results. The solubilities thus determined can be used to assess the effectiveness of solubility in limiting radionuclide migration. These solubilities can also be used to evaluate the effectiveness of other retardation processes expected to occur once dissolution of the source material and migration begin. Understanding the solubility behavior of radionuclides will assist in designing valuable sorption experiments that must be conducted below the solubility limit since only soluble species participate in surface reactions and sorption processes. The present strategy for radionuclide solubility tasks has been to provide a solubility model from bulk-experiments that attempt to bracket the estimate made for this Analysis and Modeling Report (AMR) of water conditions on site. The long-term goal must be to develop a thermodynamic database for solution speciation and solid-state determination as a prerequisite for transport calculations and interpretation of empirical solubility data. The model has to be self-consistent and tested against known solubility studies in order to predict radionuclide solubilities over the continuous distribution ranges of potential water compositions for performance assessment of the site. Solubility studies upper limits for radionuclide concentrations in natural waters. The

  12. Integrated system reliability analysis

    DEFF Research Database (Denmark)

    Gintautas, Tomas; Sørensen, John Dalsgaard

    Specific targets: 1) The report shall describe the state of the art of reliability and risk-based assessment of wind turbine components. 2) Development of methodology for reliability and risk-based assessment of the wind turbine at system level. 3) Describe quantitative and qualitative measures...

  13. Comparison of the reliability of subjective evaluation and quantitative measurements of MR signal intensity in inflammations of the intratemporal facial nerve; Vergleich der Reliabilitaet von subjektiver Beurteilung und quantitativer Messung der MR-Signalintensitaet bei Entzuendungen des intratemporalen N. facialis

    Energy Technology Data Exchange (ETDEWEB)

    Kress, B. [Universitaetsklinikum Heidelberg, Abt. Neuroradiologie (Germany); Abt. Neuroradiologie, Neurologische Klinik, Universitaetsklinik Heidelberg (Germany); Griesbeck, F. [Abt. Neurologie/Psychiatrie, Bundeswehrkrankenhaus Ulm (Germany); Stippich, C.; Sartor, K. [Abt. Neuroradiologie, Neurologische Klinik, Universitaetsklinik Heidelberg (Germany); Baehren, W. [Universitaetsklinikum Heidelberg, Abt. Neuroradiologie (Germany)

    2003-01-01

    Purpose: To compare in a single-blind study the reliability of quantitative measurements and subjective evaluations of contrast enhancement of the facial nerve in patients with idiopathic facial paralysis. Materials and Methods: Magnetic resonance images with a 0.7 mm slice thickness (surface coil) were obtained in patients with idiopathic facial paralysis before and after administration of Gd-DTPA, 0.1 mmol/kg. The five intratemporal segments of the facial nerve were quantitatively measured and subjectively assessed by five radiologists as to the degree of enhancement. The results were compared as to the reliability of both methods. Results: Using the quantitative measuring method, 175 measurements were calculated from a total of 350 regions of interest. At all 35 measured sites, the five quantitative measurements produced identical results. In contrast, the subjective assessment of the five radiologists arrived at a majority consensus in only 16 sites. A complete agreement was not reached for any measured site. Conclusion: The measured quantitative increase in signal intensity after administration of contrast medium is more reliable than subjective assessment. The quantitative method enables reproducible signal intensity measurements even for different window settings and can be easily and swiftly performed at the workstation. (orig.) [German] Untersuchungsziel: In einer einfach geblindeten Untersuchung sollte geprueft werden, wie hoch die Reliabilitaet der quantitativen Messung des Kontrastmittelanstieges im N. facialis bei idiopathischer Fazialisparese im Vergleich zur subjektiven Einschaetzung ist. Methodik: Bei 7 Patienten mit idiopathischer Fazialisparese wurde eine MRT in Duennschichttechnik (0,7 mm, nativ und nach Gabe von 0,1 mmol GdDTPA/kg) unter Verwendung einer Oberflaechenspule durchgefuehrt. 5 intratemporale Abschnitte des N. facialis wurden sowohl quantitativ als auch subjektiv durch 5 Radiologen beurteilt, und die Methoden wurden im Hinblick auf

  14. Is quantitative coronary angiography reliable in assessing the late lumen loss of the everolimus-eluting bioresorbable polylactide scaffold in comparison with the cobalt-chromium metallic stent?

    NARCIS (Netherlands)

    Sotomi, Yohei; Onuma, Yoshinobu; Miyazaki, Yosuke; Asano, Taku; Katagiri, Yuki; Tenekecioglu, Erhan; Jonker, Hans; Dijkstra, Jouke; de Winter, Robbert J.; Wykrzykowska, Joanna J.; Stone, Gregg W.; Popma, Jeffrey J.; Kozuma, Ken; Tanabe, Kengo; Serruys, Patrick W.; Kimura, Takeshi

    2017-01-01

    Aims: Immediately after stent/scaffold implantation, quantitative coronary angiography (QCA) in comparison to optical coherence tomography (OCT) more severely underestimates the lumen diameter (LD) in Absorb than in XIENCE. This OCT-QCA discrepancy has not been evaluated at long-term follow-up. The

  15. Automated approach to quantitative error analysis. [BEAPAC-1T and -3T, for testing reliability of computer codes, in FORTRAN for IBM 370/195 and CDC 6400

    Energy Technology Data Exchange (ETDEWEB)

    Bareiss, E.H.

    1977-04-01

    A method is described how a quantitative measure for the robustness of a given neutron transport theory code for coarse network calculations can be obtained. A code that performs this task automatically and at only nominal cost is described. This code also generates user-oriented benchmark problems which exhibit the analytic behavior at interfaces. 5 figures, 1 table.

  16. Reliability Engineering

    International Nuclear Information System (INIS)

    Lee, Sang Yong

    1992-07-01

    This book is about reliability engineering, which describes definition and importance of reliability, development of reliability engineering, failure rate and failure probability density function about types of it, CFR and index distribution, IFR and normal distribution and Weibull distribution, maintainability and movability, reliability test and reliability assumption in index distribution type, normal distribution type and Weibull distribution type, reliability sampling test, reliability of system, design of reliability and functionality failure analysis by FTA.

  17. Validity and reliability of the semi-quantitative self-report Home Food Availability Inventory Checklist (HFAI-C) in White and South Asian populations.

    Science.gov (United States)

    Bryant, Maria; LeCroy, Madison; Sahota, Pinki; Cai, Jianwen; Stevens, June

    2016-05-04

    Despite interest in the importance of the home food environment and its potential influence on children's diets and social norms, there remain few self-report checklist methods that have been validated against the gold standard of researcher-conducted inventories. This study aimed to assess the criterion validity and reliability of the 'Home Food Availability Inventory Checklist' (HFAI-C), a 39-item checklist including categories of fruit, vegetables, snacks and drinks. The HFAI-C was completed by 97 participants of White and Pakistani origin in the UK. Validity was determined by comparing participant-reported HFAI-C responses to data from researcher observations of home food availability using PABAK and weighted kappa statistics. The validity of measuring the amount of items (in addition to presence/absence) available was also determined. Test-retest reliability compared repeated administrations of the HFAI-C using intra-class correlation coefficients. Validity and reliability was fair to moderate overall. For validity, the average category-level PABAK ranged from 0.31 (95% CI: 0.25, 0.37) for vegetables to 0.44 (95% CI: 0.40, 0.49) for fruits. Assessment of the presence/absence of items demonstrated higher validity compared to quantity measurements. Reliability was increased when the HFAI-C was repeated close to the time of the first administration. For example, ICCs for reliability of the measurement of fruits were 0.52 (95%CI: 0.47, 0.56) if re-administered within 5 months, 0.58 (95% CI: 0.51, 0.64) within 30 days and 0.97 (95%CI: 0.94, 1.00) if re-administered on the same day. Overall, the HFAI-C demonstrated fair to moderate validity and reliability in a population of White and South Asian participants. This evaluation is consistent with previous work on other checklists in less diverse, more affluent populations. Our research supports the use of the HFAI-C as a useful, albeit imperfect, representation of researcher-conducted inventories. The feasibility of

  18. In situ high-pressure measurement of crystal solubility by using neutron diffraction

    Science.gov (United States)

    Chen, Ji; Hu, Qiwei; Fang, Leiming; He, Duanwei; Chen, Xiping; Xie, Lei; Chen, Bo; Li, Xin; Ni, Xiaolin; Fan, Cong; Liang, Akun

    2018-05-01

    Crystal solubility is one of the most important thermo-physical properties and plays a key role in industrial applications, fundamental science, and geoscientific research. However, high-pressure in situ measurements of crystal solubility remain very challenging. Here, we present a method involving high-pressure neutron diffraction for making high-precision in situ measurements of crystal solubility as a function of pressure over a wide range of pressures. For these experiments, we designed a piston-cylinder cell with a large chamber volume for high-pressure neutron diffraction. The solution pressures are continuously monitored in situ based on the equation of state of the sample crystal. The solubility at a high pressure can be obtained by applying a Rietveld quantitative multiphase analysis. To evaluate the proposed method, we measured the high-pressure solubility of NaCl in water up to 610 MPa. At a low pressure, the results are consistent with the previous results measured ex situ. At a higher pressure, more reliable data could be provided by using an in situ high-pressure neutron diffraction method.

  19. Rapid determination of water- and fat-soluble vitamins with microemulsion electrokinetic chromatography.

    Science.gov (United States)

    Yin, Changna; Cao, Yuhua; Ding, Shaodong; Wang, Yun

    2008-06-06

    A rapid, reliable and reproducible method based on microemulsion electrokinetic chromatography (MEEKC) for simultaneous determination of 13 kinds of water- and fat-soluble vitamins has been developed in this work. A novel microemulsion system consisting of 1.2% (w/w) sodium lauryl sulphate (SDS), 21% (v/v) 1-butanol, 18% (v/v) acetonitrile, 0.8% (w/w) n-hexane, 20mM borax buffer (pH 8.7) was applied to improve selectivity and efficiency, as well as shorten analysis time. The composition of microemulsion used as the MEEKC running buffer was investigated thoroughly to obtain stable separation medium, as well as the optimum determination conditions. Acetonitrile as the organic solvent modifier, pH of the running buffer and 1-butanol as the co-surfactant played the most important roles for the separation of the fat-soluble vitamins, water-soluble vitamins and stabilization of system, respectively. The 13 water- and fat-soluble vitamins were baseline separated within 30 min. The system was applied to determine water- and fat-soluble vitamins in commercial multivitamin pharmaceutical formulation, good accuracy and precision were obtained with recoveries between 97% and 105%, relative standard derivations (RSDs) less than 1.8% except vitamin C, and acceptable quantitative results corresponding to label claim.

  20. Experimental studies to validate model calculations and maximum solubility limits for Plutonium and Americium

    International Nuclear Information System (INIS)

    2017-01-01

    This report focuses on studies of KIT-INE to derive a significantly improved description of the chemical behaviour of Americium and Plutonium in saline NaCl, MgCl 2 and CaCl 2 brine systems. The studies are based on new experimental data and aim at deriving reliable Am and Pu solubility limits for the investigated systems as well as deriving comprehensive thermodynamic model descriptions. Both aspects are of high relevance in the context of potential source term estimations for Americium and Plutonium in aqueous brine systems and related scenarios. Americium and Plutonium are long-lived alpha emitting radionuclides which due to their high radiotoxicity need to be accounted for in a reliable and traceable way. The hydrolysis of trivalent actinides and the effect of highly alkaline pH conditions on the solubility of trivalent actinides in calcium chloride rich brine solutions were investigated and a thermodynamic model derived. The solubility of Plutonium in saline brine systems was studied under reducing and non-reducing conditions and is described within a new thermodynamic model. The influence of dissolved carbonate on Americium and Plutonium solubility in MgCl 2 solutions was investigated and quantitative information on Am and Pu solubility limits in these systems derived. Thermodynamic constants and model parameter derived in this work are implemented in the Thermodynamic Reference Database THEREDA owned by BfS. According to the quality assurance approach in THEREDA, is was necessary to publish parts of this work in peer-reviewed scientific journals. The publications are focused on solubility experiments, spectroscopy of aquatic and solid species and thermodynamic data. (Neck et al., Pure Appl. Chem., Vol. 81, (2009), pp. 1555-1568., Altmaier et al., Radiochimica Acta, 97, (2009), pp. 187-192., Altmaier et al., Actinide Research Quarterly, No 2., (2011), pp. 29-32.).

  1. Neptunium (IV) oxalate solubility

    International Nuclear Information System (INIS)

    Luerkens, D.W.

    1983-07-01

    The equilibrium solubility of neptunium (IV) oxalate in nitric/oxalic acid solutions was determined at 22 0 C, 45 0 C, and 60 0 C. The concentrations of nitric/oxalic acid solutions represented a wide range of free oxalate ion concentration. A mathematical solubility model was developed which is based on the formation of the known complexes of neptunium (IV) oxalate. the solubility model uses a simplified concentration parameter which is proportional to the free oxalate ion concentration. The solubility model can be used to estimate the equilibrium solubility of neptunium (IV) oxalate over a wide range of oxalic and nitric acid concentrations at each temperature

  2. Quantitative measurement of vitamin K2 (menaquinones) in various fermented dairy products using a reliable high-performance liquid chromatography method.

    Science.gov (United States)

    Manoury, E; Jourdon, K; Boyaval, P; Fourcassié, P

    2013-03-01

    We evaluated menaquinone contents in a large set of 62 fermented dairy products samples by using a new liquid chromatography method for accurate quantification of lipo-soluble vitamin K(2), including distribution of individual menaquinones. The method used a simple and rapid purification step to remove matrix components in various fermented dairy products 3 times faster than a reference preparation step. Moreover, the chromatography elution time was significantly shortened and resolution and efficiency were optimized. We observed wide diversity of vitamin K(2) contents in the set of fermented dairy products, from undetectable to 1,100 ng/g of product, and a remarkable diversity of menaquinone forms among products. These observations relate to the main microorganism species currently in the different fermented product technologies. The major form in this large set of fermented dairy products was menaquinone (MK)-9, and contents of MK-9 and MK-8 forms were correlated, that of MK-9 being around 4 times that of MK-8, suggesting that microorganisms able to produce MK-9 also produce MK-8. This was not the case for the other menaquinones, which were produced independently of each other. Finally, no obvious link was established between MK-9 content and fat content or pH of the fermented dairy products. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Quantitative research.

    Science.gov (United States)

    Watson, Roger

    2015-04-01

    This article describes the basic tenets of quantitative research. The concepts of dependent and independent variables are addressed and the concept of measurement and its associated issues, such as error, reliability and validity, are explored. Experiments and surveys – the principal research designs in quantitative research – are described and key features explained. The importance of the double-blind randomised controlled trial is emphasised, alongside the importance of longitudinal surveys, as opposed to cross-sectional surveys. Essential features of data storage are covered, with an emphasis on safe, anonymous storage. Finally, the article explores the analysis of quantitative data, considering what may be analysed and the main uses of statistics in analysis.

  4. Contribution to a quantitative assessment model for reliability-based metrics of electronic and programmable safety-related functions; Contribution a un modele d'evaluation quantitative des performances fiabilistes de fonctions electroniques et programmables dediees a la securite

    Energy Technology Data Exchange (ETDEWEB)

    Hamidi, K

    2005-10-15

    The use of fault-tolerant EP architectures has induced growing constraints, whose influence on reliability-based performance metrics is no more negligible. To face up the growing influence of simultaneous failure, this thesis proposes, for safety-related functions, a new-trend assessment method of reliability, based on a better taking into account of time-aspect. This report introduces the concept of information and uses it to interpret the failure modes of safety-related function as the direct result of the initiation and propagation of erroneous information until the actuator-level. The main idea is to distinguish the apparition and disappearance of erroneous states, which could be defined as intrinsically dependent of HW-characteristic and maintenance policies, and their possible activation, constrained through architectural choices, leading to the failure of safety-related function. This approach is based on a low level on deterministic SED models of the architecture and use non homogeneous Markov chains to depict the time-evolution of probabilities of errors. (author)

  5. Contribution to a quantitative assessment model for reliability-based metrics of electronic and programmable safety-related functions; Contribution a un modele d'evaluation quantitative des performances fiabilistes de fonctions electroniques et programmables dediees a la securite

    Energy Technology Data Exchange (ETDEWEB)

    Hamidi, K

    2005-10-15

    The use of fault-tolerant EP architectures has induced growing constraints, whose influence on reliability-based performance metrics is no more negligible. To face up the growing influence of simultaneous failure, this thesis proposes, for safety-related functions, a new-trend assessment method of reliability, based on a better taking into account of time-aspect. This report introduces the concept of information and uses it to interpret the failure modes of safety-related function as the direct result of the initiation and propagation of erroneous information until the actuator-level. The main idea is to distinguish the apparition and disappearance of erroneous states, which could be defined as intrinsically dependent of HW-characteristic and maintenance policies, and their possible activation, constrained through architectural choices, leading to the failure of safety-related function. This approach is based on a low level on deterministic SED models of the architecture and use non homogeneous Markov chains to depict the time-evolution of probabilities of errors. (author)

  6. Identification and Evaluation of Reliable Reference Genes for Quantitative Real-Time PCR Analysis in Tea Plant (Camellia sinensis (L.) O. Kuntze)

    Science.gov (United States)

    Hao, Xinyuan; Horvath, David P.; Chao, Wun S.; Yang, Yajun; Wang, Xinchao; Xiao, Bin

    2014-01-01

    Reliable reference selection for the accurate quantification of gene expression under various experimental conditions is a crucial step in qRT-PCR normalization. To date, only a few housekeeping genes have been identified and used as reference genes in tea plant. The validity of those reference genes are not clear since their expression stabilities have not been rigorously examined. To identify more appropriate reference genes for qRT-PCR studies on tea plant, we examined the expression stability of 11 candidate reference genes from three different sources: the orthologs of Arabidopsis traditional reference genes and stably expressed genes identified from whole-genome GeneChip studies, together with three housekeeping gene commonly used in tea plant research. We evaluated the transcript levels of these genes in 94 experimental samples. The expression stabilities of these 11 genes were ranked using four different computation programs including geNorm, Normfinder, BestKeeper, and the comparative ∆CT method. Results showed that the three commonly used housekeeping genes of CsTUBULIN1, CsACINT1 and Cs18S rRNA1 together with CsUBQ1 were the most unstable genes in all sample ranking order. However, CsPTB1, CsEF1, CsSAND1, CsCLATHRIN1 and CsUBC1 were the top five appropriate reference genes for qRT-PCR analysis in complex experimental conditions. PMID:25474086

  7. Water-soluble vitamins.

    Science.gov (United States)

    Konings, Erik J M

    2006-01-01

    combination of enzymes and reaction conditions may vary depending on the composition of the food. Padrangi and Laborde showed recently that treatment with alpha-amylase had no significant effect on measured folate in spinach, although addition of protease significantly increased the release of folate. LC/MS applications gain increasing attention because of their specificity. Rychlik used stable isotope dilution assays for the determination of the folate content of broccoli and bread. Compared to data in the literature and food data bases, amounts were significantly lower. Pawlosky et al., however, found comparable values for 5-methyltetrahydrofolic acid and folic acid by HPLC analysis with fluorescent detection and HPLC/MS. Among samples analyzed were CRMs and broccoli. Besides folic acid, other water-soluble vitamins were also determined by LC/MS/MS by Leporati et al. The method was applied to the quantitative analysis of the natural content of vitamins in typical Italian pasta samples, as well as in fortified pasta samples produced for the U.S. market. Biotin.-A paper from Staggs et al. included the assertion that existing biotin data in food composition tables are inaccurate because the majority are based on bioassays with all relevant disadvantages. Data in most cases are overestimated with consequences for recommendations for dietary biotin intake. An HPLC/avidin-binding assay was used to analyze 87 foods to support the hypothesis mentioned.

  8. Short-term test-retest-reliability of conditioned pain modulation using the cold-heat-pain method in healthy subjects and its correlation to parameters of standardized quantitative sensory testing.

    Science.gov (United States)

    Gehling, Julia; Mainka, Tina; Vollert, Jan; Pogatzki-Zahn, Esther M; Maier, Christoph; Enax-Krumova, Elena K

    2016-08-05

    Conditioned Pain Modulation (CPM) is often used to assess human descending pain inhibition. Nine different studies on the test-retest-reliability of different CPM paradigms have been published, but none of them has investigated the commonly used heat-cold-pain method. The results vary widely and therefore, reliability measures cannot be extrapolated from one CPM paradigm to another. Aim of the present study was to analyse the test-retest-reliability of the common heat-cold-pain method and its correlation to pain thresholds. We tested the short-term test-retest-reliability within 40 ± 19.9 h using a cold-water immersion (10 °C, left hand) as conditioning stimulus (CS) and heat pain (43-49 °C, pain intensity 60 ± 5 on the 101-point numeric rating scale, right forearm) as test stimulus (TS) in 25 healthy right-handed subjects (12females, 31.6 ± 14.1 years). The TS was applied 30s before (TSbefore), during (TSduring) and after (TSafter) the 60s CS. The difference between the pain ratings for TSbefore and TSduring represents the early CPM-effect, between TSbefore and TSafter the late CPM-effect. Quantitative sensory testing (QST, DFNS protocol) was performed on both sessions before the CPM assessment. paired t-tests, Intraclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD), Pearson's correlation, Bland-Altman analysis, significance level p Pain ratings during CPM correlated significantly (ICC: 0.411…0.962) between both days, though ratings for TSafter were lower on day 2 (p pain thresholds. The short-term test-retest-reliability of the early CPM-effect using the heat-cold-pain method in healthy subjects achieved satisfying results in terms of the ICC. The SRD of the early CPM effect showed that an individual change of > 20 NRS can be attributed to a real change rather than chance. The late CPM-effect was weaker and not reliable.

  9. Selection of Reliable Reference Genes for Gene Expression Studies in the Biofuel Plant Jatropha curcas Using Real-Time Quantitative PCR

    Directory of Open Access Journals (Sweden)

    Lu Zhang

    2013-12-01

    Full Text Available Jatropha curcas is a promising renewable feedstock for biodiesel and bio-jet fuel production. To study gene expression in Jatropha in different tissues throughout development and under stress conditions, we examined a total of 11 typical candidate reference genes using real-time quantitative polymerase chain reaction (RT-qPCR analysis, which is widely used for validating transcript levels in gene expression studies. The expression stability of these candidate reference genes was assessed across a total of 20 samples, including various tissues at vegetative and reproductive stages and under desiccation and cold stress treatments. The results obtained using software qBasePLUS showed that the top-ranked reference genes differed across the sample subsets. The combination of actin, GAPDH, and EF1α would be appropriate as a reference panel for normalizing gene expression data across samples at different developmental stages; the combination of actin, GAPDH, and TUB5 should be used as a reference panel for normalizing gene expression data across samples under various abiotic stress treatments. With regard to different developmental stages, we recommend the use of actin and TUB8 for normalization at the vegetative stage and GAPDH and EF1α for normalization at the reproductive stage. For abiotic stress treatments, we recommend the use of TUB5 and TUB8 for normalization under desiccation stress and GAPDH and actin for normalization under cold stress. These results are valuable for future research on gene expression during development or under abiotic stress in Jatropha. To our knowledge, this is the first report on the stability of reference genes in Jatropha.

  10. Plasma soluble prion protein, a potential biomarker for sport-related concussions: a pilot study.

    Science.gov (United States)

    Pham, Nam; Akonasu, Hungbo; Shishkin, Rhonda; Taghibiglou, Changiz

    2015-01-01

    Sport-related mild traumatic brain injury (mTBI) or concussion is a significant health concern to athletes with potential long-term consequences. The diagnosis of sport concussion and return to sport decision making is one of the greatest challenges facing health care clinicians working in sports. Blood biomarkers have recently demonstrated their potential in assisting the detection of brain injury particularly, in those cases with no obvious physical injury. We have recently discovered plasma soluble cellular prion protein (PrP(C)) as a potential reliable biomarker for blast induced TBI (bTBI) in a rodent animal model. In order to explore the application of this novel TBI biomarker to sport-related concussion, we conducted a pilot study at the University of Saskatchewan (U of S) by recruiting athlete and non-athlete 18 to 30 year-old students. Using a modified quantitative ELISA method, we first established normal values for the plasma soluble PrP(C) in male and female students. The measured plasma soluble PrP(C) in confirmed concussion cases demonstrated a significant elevation of this analyte in post-concussion samples. Data collected from our pilot study indicates that the plasma soluble PrP(C) is a potential biomarker for sport-related concussion, which may be further developed into a clinical diagnostic tool to assist clinicians in the assessment of sport concussion and return-to-play decision making.

  11. Solubility of metallic elements in LBE under extra low oxygen potential. JFY2001 joint research report

    International Nuclear Information System (INIS)

    Sano, Hiroyuki; Fujisawa, Toshiharu

    2002-03-01

    Lead-Bismuth eutectic alloy (LBE) has been considered as a prospective coolant for a fast-breeder reactor. However a corrosion of cooling pipe is anticipated when it is used at the similar temperature as sodium coolant. In this study, solubility of major metallic elements in LBE is to be measured under extra low oxygen potential. The interactive effect of those elements on the solubility is also to be examined. As a first step, measurements of the solubility of iron in LBE at 673 K were conducted where the partial pressure of oxygen was controlled by using equilibrium between iron and its oxide. Several experimental runs were conducted. But relationship between iron content and oxygen content in LBE could not be defined precisely, because chemical reactions proceeded very slowly at such a low temperature and reliable enough data have not been obtained yet until now. Based on the above results, following subjects were extracted for JFY2002 study. (1) To establish the method of quantitative analysis of oxygen content in LBE. (2) To obtain the solubility data at elevated temperature, then approach to lower temperature. (3) To control the oxygen partial pressure in LBE by CO-CO 2 mixed gases supply. (author)

  12. The solubility and diffusivity of hydrogen in well-annealed and deformed iron

    International Nuclear Information System (INIS)

    Kiuchi, K.; McLellan, R.B.

    1983-01-01

    It has been shown that a large volume of data for the solubility of hydrogen in iron is affected by spurious surface conditions. Arrhenius plots of solubility data in the temperature range 300-1750 K, which are free of such effects, exhibit a temperature variation which, despite the low H-solubility in the entire temperature range, is not consistent with regular mixing statistics. This departure from regular behavior is consistent with the thermal activation of H atoms into energetically less favorable octahedral sites as the temperature is increased. The enhancement in H-solubility caused by the cold deformation of iron can be understood in terms of a simple Maxwell-Boltzmann distribution of H atoms between ''normal'' lattice sites and ''trapping'' sites of depth 34 kJ/mol. The 62 currently existing sets of data for the diffusivity of hydrogen through b.c.c. iron exhibit a large degree of mutual inconsistency. Exhaustive statistical analysis of this large data mass has shown that only those data obtained by electrochemical methods and H 2 -gas equilibration methods using UHV techniques and Pd-coated membranes are reliable. The problem of H-diffusion in deformed iron has been analysed using a semi-quantitative model in which the retarding effect of trapping sites on the diffusivity is partially compensated by a ''pipe'' diffusion contribution along dislocations. It is shown that this model is in accord with the diffusivities measured in deformed iron when data not encumbered by spurious surface effects are considered

  13. Plasma soluble prion protein, a potential biomarker for sport-related concussions: a pilot study.

    Directory of Open Access Journals (Sweden)

    Nam Pham

    Full Text Available Sport-related mild traumatic brain injury (mTBI or concussion is a significant health concern to athletes with potential long-term consequences. The diagnosis of sport concussion and return to sport decision making is one of the greatest challenges facing health care clinicians working in sports. Blood biomarkers have recently demonstrated their potential in assisting the detection of brain injury particularly, in those cases with no obvious physical injury. We have recently discovered plasma soluble cellular prion protein (PrP(C as a potential reliable biomarker for blast induced TBI (bTBI in a rodent animal model. In order to explore the application of this novel TBI biomarker to sport-related concussion, we conducted a pilot study at the University of Saskatchewan (U of S by recruiting athlete and non-athlete 18 to 30 year-old students. Using a modified quantitative ELISA method, we first established normal values for the plasma soluble PrP(C in male and female students. The measured plasma soluble PrP(C in confirmed concussion cases demonstrated a significant elevation of this analyte in post-concussion samples. Data collected from our pilot study indicates that the plasma soluble PrP(C is a potential biomarker for sport-related concussion, which may be further developed into a clinical diagnostic tool to assist clinicians in the assessment of sport concussion and return-to-play decision making.

  14. Structural Reliability Methods

    DEFF Research Database (Denmark)

    Ditlevsen, Ove Dalager; Madsen, H. O.

    The structural reliability methods quantitatively treat the uncertainty of predicting the behaviour and properties of a structure given the uncertain properties of its geometry, materials, and the actions it is supposed to withstand. This book addresses the probabilistic methods for evaluation...... of structural reliability, including the theoretical basis for these methods. Partial safety factor codes under current practice are briefly introduced and discussed. A probabilistic code format for obtaining a formal reliability evaluation system that catches the most essential features of the nature...... of the uncertainties and their interplay is the developed, step-by-step. The concepts presented are illustrated by numerous examples throughout the text....

  15. X-radiation effect on soluble proteins of gastric mucosa

    International Nuclear Information System (INIS)

    Sukhomlinov, B.F.; Chajka, Ya.P.; Fedorovich, A.N.

    1979-01-01

    Using the method of electrophoresis in agar gel soluble proteins of gastric mucosa of rats were separated into 11 fractions. Proteins posessing a proteolytic (pH 1.8) and lipase (pH 7.4) activity were localized within the second and third prealbumin fractions. Soluble proteins of gastric mucosa contain glyco- and lipoproteid complexes. Exposure of rats to 1000 R of X-rays induces quantitative redistribution within the electrophoretic spectrum of soluble proteins and a considerable disturbance of the proteolytic activity of total soluble proteins throughout the entire period of observation (from 10 min to 72h)

  16. Software reliability

    CERN Document Server

    Bendell, A

    1986-01-01

    Software Reliability reviews some fundamental issues of software reliability as well as the techniques, models, and metrics used to predict the reliability of software. Topics covered include fault avoidance, fault removal, and fault tolerance, along with statistical methods for the objective assessment of predictive accuracy. Development cost models and life-cycle cost models are also discussed. This book is divided into eight sections and begins with a chapter on adaptive modeling used to predict software reliability, followed by a discussion on failure rate in software reliability growth mo

  17. Enhanced reliability and accuracy for field deployable bioforensic detection and discrimination of Xylella fastidiosa subsp. pauca, causal agent of citrus variegated chlorosis using razor ex technology and TaqMan quantitative PCR.

    Science.gov (United States)

    Ouyang, Ping; Arif, Mohammad; Fletcher, Jacqueline; Melcher, Ulrich; Ochoa Corona, Francisco Manuel

    2013-01-01

    A reliable, accurate and rapid multigene-based assay combining real time quantitative PCR (qPCR) and a Razor Ex BioDetection System (Razor Ex) was validated for detection of Xylella fastidiosa subsp. pauca (Xfp, a xylem-limited bacterium that causes citrus variegated chlorosis [CVC]). CVC, which is exotic to the United States, has spread through South and Central America and could significantly impact U.S. citrus if it arrives. A method for early, accurate and sensitive detection of Xfp in plant tissues is needed by plant health officials for inspection of products from quarantined locations, and by extension specialists for detection, identification and management of disease outbreaks and reservoir hosts. Two sets of specific PCR primers and probes, targeting Xfp genes for fimbrillin and the periplasmic iron-binding protein were designed. A third pair of primers targeting the conserved cobalamin synthesis protein gene was designed to detect all possible X. fastidiosa (Xf) strains. All three primer sets detected as little as 1 fg of plasmid DNA carrying X. fastidiosa target sequences and genomic DNA of Xfp at as little as 1 - 10 fg. The use of Razor Ex facilitates a rapid (about 30 min) in-field assay capability for detection of all Xf strains, and for specific detection of Xfp. Combined use of three primer sets targeting different genes increased the assay accuracy and broadened the range of detection. To our knowledge, this is the first report of a field-deployable rapid and reliable bioforensic detection and discrimination method for a bacterial phytopathogen based on multigene targets.

  18. Human reliability

    International Nuclear Information System (INIS)

    Embrey, D.E.

    1987-01-01

    Concepts and techniques of human reliability have been developed and are used mostly in probabilistic risk assessment. For this, the major application of human reliability assessment has been to identify the human errors which have a significant effect on the overall safety of the system and to quantify the probability of their occurrence. Some of the major issues within human reliability studies are reviewed and it is shown how these are applied to the assessment of human failures in systems. This is done under the following headings; models of human performance used in human reliability assessment, the nature of human error, classification of errors in man-machine systems, practical aspects, human reliability modelling in complex situations, quantification and examination of human reliability, judgement based approaches, holistic techniques and decision analytic approaches. (UK)

  19. Reliability Calculations

    DEFF Research Database (Denmark)

    Petersen, Kurt Erling

    1986-01-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety...... and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic...... approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very...

  20. OSS reliability measurement and assessment

    CERN Document Server

    Yamada, Shigeru

    2016-01-01

    This book analyses quantitative open source software (OSS) reliability assessment and its applications, focusing on three major topic areas: the Fundamentals of OSS Quality/Reliability Measurement and Assessment; the Practical Applications of OSS Reliability Modelling; and Recent Developments in OSS Reliability Modelling. Offering an ideal reference guide for graduate students and researchers in reliability for open source software (OSS) and modelling, the book introduces several methods of reliability assessment for OSS including component-oriented reliability analysis based on analytic hierarchy process (AHP), analytic network process (ANP), and non-homogeneous Poisson process (NHPP) models, the stochastic differential equation models and hazard rate models. These measurement and management technologies are essential to producing and maintaining quality/reliable systems using OSS.

  1. Thermal degradation of organo-soluble polyimides

    Institute of Scientific and Technical Information of China (English)

    黄俐研; 史燚; 金熹高

    1999-01-01

    The thermal degradation behavior of two organo-soluble polyimides was investigated by high resolution pyrolysis-gas chromatography/mass spectrometry. The pyrolyzates of the polymers at various temperatures were identified and characterized quantitatively. The relationship between the polymer structure and pyrolyzate distribution was discussed. The kinetic parameters of the thermal degradation were calculated based on thermogravimetric measurements. Finally, the thermal degradation mechanism for the polymers was suggested.

  2. Quantitative lymphography

    International Nuclear Information System (INIS)

    Mostbeck, A.; Lofferer, O.; Kahn, P.; Partsch, H.; Koehn, H.; Bialonczyk, Ch.; Koenig, B.

    1984-01-01

    Labelled colloids and macromolecules are removed lymphatically. The uptake of tracer in the regional lymphnodes is a parameter of lymphatic flow. Due to great variations in patient shape - obesity, cachexia - and accompanying variations in counting efficiencies quantitative measurements with reasonable accuracy have not been reported to date. A new approach to regional absorption correction is based on the combination of transmission and emission scans for each patient. The transmission scan is used for calculation of an absorption correction matrix. Accurate superposition of the correction matrix and the emission scan is achieved by computing the centers of gravity of point sources and - in the case of aligning opposite views - by cross correlation of binary images. In phantom studies the recovery was high (98.3%) and the coefficient of variation of repeated measurement below 1%. In patient studies a standardized stress is a prerequisite for reliable and comparable results. Discrimination between normals (14.3 +- 4.2D%) and patients with lymphedema (2.05 +- 2.5D%) was highly significant using praefascial lymphography and sc injection. Clearence curve analysis of the activities at the injection site, however, gave no reliable data for this purpose. In normals, the uptake in lymphnodes after im injection is by one order of magnitude lower then the uptake after sc injection. The discrimination between normals and patients with postthromboic syndrome was significant. Lymphography after ic injection was in the normal range in 2/3 of the patients with lymphedema and is therefore of no diagnostic value. The difference in uptake after ic and sc injection demonstrated for the first time by our quantitative method provides new insights into the pathophysiology of lymphedema and needs further investigation. (Author)

  3. Soluble CD163

    DEFF Research Database (Denmark)

    Møller, Holger J

    2012-01-01

    CD163 is an endocytic receptor for haptoglobin-hemoglobin complexes and is expressed solely on macrophages and monocytes. As a result of ectodomain shedding, the extracellular portion of CD163 circulates in blood as a soluble protein (sCD163) at 0.7-3.9 mg/l in healthy individuals. The function o...

  4. Solubility Part 1

    NARCIS (Netherlands)

    Tantra, Ratna; Bolea, Eduardo; Bouwmeester, H.; Rey-Castro, Carlos; David, C.A.A.; Dogné, Jean Michel; Laborda, Francisco; Laloy, Julie; Robinson, Kenneth N.; Undas, A.K.; Zande, van der M.

    2016-01-01

    This chapter gives an overview of different methods that can potentially be used to determine the solubility of nanomaterials. In general, the methods presented can be broadly divided into four categories: separation methods, methods to quantify free ions, methods to quantify total dissolved

  5. Author's reply to 'Comment on 'Plutonium chemistry: a synthesis of experimental data and a quantitative model for plutonium oxide solubility' by J.M. Haschke and V.M. Oversby'

    International Nuclear Information System (INIS)

    Haschke, John M.

    2004-01-01

    In the accompanying letter, Newton and Hobart comment on a recent paper [J. Nucl. Mater. 305 (2002) 187] and conclude that a proposed alternative explanation for self-reduction of Pu(VI) is based on misinterpretation of data. Result of quantitative kinetic modeling contradicts this conclusion and the accepted explanation by showing that self-induced α-particle reduction of 239 Pu(VI) at pH 1.5 does not account for the observed reduction rate of Pu(VI) or for dependence of the rate on [Pu(VI)]. Similar modeling shows that kinetic behavior is consistent with a self-reduction process based on disproportionation of Pu(VI). Validity of the alternative concept is supported by close similarities in the kinetic behavior of Pu(V) and Pu(VI)

  6. The objective of this program is to develop innovative DNA detection technologies to achieve fast microbial community assessment. The specific approaches are (1) to develop inexpensive and reliable sequence-proof hybridization DNA detection technology (2) to develop quantitative DNA hybridization technology for microbial community assessment and (3) to study the microbes which have demonstrated the potential to have nuclear waste bioremediation

    International Nuclear Information System (INIS)

    Chen, Chung H.

    2004-01-01

    The objective of this program is to develop innovative DNA detection technologies to achieve fast microbial community assessment. The specific approaches are (1) to develop inexpensive and reliable sequence-proof hybridization DNA detection technology (2) to develop quantitative DNA hybridization technology for microbial community assessment and (3) to study the microbes which have demonstrated the potential to have nuclear waste bioremediation

  7. Reliability Engineering

    CERN Document Server

    Lazzaroni, Massimo

    2012-01-01

    This book gives a practical guide for designers and users in Information and Communication Technology context. In particular, in the first Section, the definition of the fundamental terms according to the international standards are given. Then, some theoretical concepts and reliability models are presented in Chapters 2 and 3: the aim is to evaluate performance for components and systems and reliability growth. Chapter 4, by introducing the laboratory tests, puts in evidence the reliability concept from the experimental point of view. In ICT context, the failure rate for a given system can be

  8. Reliability training

    Science.gov (United States)

    Lalli, Vincent R. (Editor); Malec, Henry A. (Editor); Dillard, Richard B.; Wong, Kam L.; Barber, Frank J.; Barina, Frank J.

    1992-01-01

    Discussed here is failure physics, the study of how products, hardware, software, and systems fail and what can be done about it. The intent is to impart useful information, to extend the limits of production capability, and to assist in achieving low cost reliable products. A review of reliability for the years 1940 to 2000 is given. Next, a review of mathematics is given as well as a description of what elements contribute to product failures. Basic reliability theory and the disciplines that allow us to control and eliminate failures are elucidated.

  9. WHIM-3D-QSPR APPROACH FOR PREDICTING AQUEOUS SOLUBILITY OF CHLORINATED HYDROCARBONS

    Directory of Open Access Journals (Sweden)

    Oman Zuas

    2010-06-01

    Full Text Available The weighted holistic invariant molecular-three dimensional-quantitative structure property relationship (WHIM-3D-QSPR approach has been applied to the study of the aqueous solubility (- log Sw of chlorinated hydrocarbon compounds (CHC's. The obtained QSPR model is predictive and only requires four WHIM-3D descriptors in the calculation. The correlation equation of the model that is based on a training set of 50 CHC's compound has statistical parameters: standard coefficient correlation (R2 = 0.948; cross-validated correlation coefficients (Q2 = 0.935; Standard Error of Validation (SEV = 0.35; and average absolute error (AAE = 0.31. The application of the best model to a testing set of 50 CHC's demonstrates a reliable result with good predictability. Besides, it was possible to construct new model by applying WHIM-3D-QSPR approach without require any experimental physicochemical properties in the calculation of aqueous solubility.   Keywords: WHIM-3D; QSPR; aqueous solubility; - Log Sw, chlorinated hydrocarbons, CHC's

  10. Solubility of inorganic salts in pure ionic liquids

    International Nuclear Information System (INIS)

    Pereiro, A.B.; Araújo, J.M.M.; Oliveira, F.S.; Esperança, J.M.S.S.; Canongia Lopes, J.N.; Marrucho, I.M.; Rebelo, L.P.N.

    2012-01-01

    Highlights: ► We report the solubility of different conventional salts in several ionic liquids. ► The solubility was initially screened using a visual detection method. ► The most promising mixtures were quantitatively re-measured using an ATR–FTIR. - Abstract: The solubility of different conventional salts in several room-temperature ionic liquids – containing ammonium, phosphonium or imidazolium cations combined with acetate, sulfate, sulfonate, thiocyanate, chloride, tetracyano-borate, tris(pentafluoroethyl)trifluoro-phosphate, L-lactate, bis(trifluoromethylsulfonyl)imide or trifluoromethylsulfonate anions – were screened using a visual detection method. The most promising mixtures were then re-measured using an ATR–FTIR (Attenuated Total Reflection Fourier Transform Infra Red) spectroscopy technique in order to accurately and quantitatively determine the corresponding solubility at 298.15 K.

  11. Thermodynamic data development using the solubility method (Joint research)

    International Nuclear Information System (INIS)

    Rai, Dhanpat; Yui, Mikazu

    2013-05-01

    The solubility method is one of the most powerful tools to obtain reliable thermodynamic data for 1) solubility products of discrete solids and double salts, 2) complexation constants for various ligands, 3) development of data in a wide range of pH values, 4) evaluation of data for metals that form very insoluble solids (e.g. tetravalent actinides), 5) determining solubility-controlling solids in different types of wastes and 6) elevated temperatures for redox sensitive systems. This document is focused on describing various aspects of obtaining thermodynamic data using the solubility method. This manuscript deals with various aspects of conducting solubility studies, including selecting the study topic, modeling to define important variables, selecting the range of variables and experimental parameters, anticipating results, general equipment requirements, conducting experiments, and interpreting experimental data. (author)

  12. Reliability calculations

    International Nuclear Information System (INIS)

    Petersen, K.E.

    1986-03-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very complex systems. In order to increase the applicability of the programs variance reduction techniques can be applied to speed up the calculation process. Variance reduction techniques have been studied and procedures for implementation of importance sampling are suggested. (author)

  13. Systems reliability/structural reliability

    International Nuclear Information System (INIS)

    Green, A.E.

    1980-01-01

    The question of reliability technology using quantified techniques is considered for systems and structures. Systems reliability analysis has progressed to a viable and proven methodology whereas this has yet to be fully achieved for large scale structures. Structural loading variants over the half-time of the plant are considered to be more difficult to analyse than for systems, even though a relatively crude model may be a necessary starting point. Various reliability characteristics and environmental conditions are considered which enter this problem. The rare event situation is briefly mentioned together with aspects of proof testing and normal and upset loading conditions. (orig.)

  14. Uranyl Oxalate Solubility

    Energy Technology Data Exchange (ETDEWEB)

    Leturcq, G.; Costenoble, S.; Grandjean, S. [CEA Marcoule DEN/DRCP/SCPS/LCA - BP17171 - 30207 Bagnols sur Ceze cedex (France)

    2008-07-01

    The solubility of uranyl oxalate was determined at ambient temperature by precipitation in oxalic-nitric solutions, using an initial uranyl concentration of 0.1 mol/L. Oxalic concentration varied from 0.075 to 0.3 mol/L while nitric concentration ranged between 0.75 and 3 mol/L. Dissolution tests, using complementary oxalic-nitric media, were carried out for 550 hours in order to study the kinetic to reach thermodynamic equilibrium. Similar solubility values were reached by dissolution and precipitation. Using the results, it was possible to draw the solubility surface versus oxalic and nitric concentrations and to determine both the apparent solubility constant of UO{sub 2}C{sub 2}O{sub 4}, 3H{sub 2}O (Ks) and the apparent formation constant of the first uranyl-oxalate complex UO{sub 2}C{sub 2}O{sub 4} (log {beta}1), for ionic strengths varying between 1 and 3 mol/L. Ks and log {beta}1 values were found to vary from 1.9 10{sup -8} to 9.2 10{sup -9} and from 5.95 to 6.06, respectively, when ionic strength varied from 1 to 3 mol/L. A second model may fit our data obtained at an ionic strength of 3 mol/L suggesting as reported by Moskvin et al. (1959) that no complexes are formed for [H{sup +}] at 3 M. The Ks value would then be 1.3 10{sup -8}. (authors)

  15. Human reliability

    International Nuclear Information System (INIS)

    Bubb, H.

    1992-01-01

    This book resulted from the activity of Task Force 4.2 - 'Human Reliability'. This group was established on February 27th, 1986, at the plenary meeting of the Technical Reliability Committee of VDI, within the framework of the joint committee of VDI on industrial systems technology - GIS. It is composed of representatives of industry, representatives of research institutes, of technical control boards and universities, whose job it is to study how man fits into the technical side of the world of work and to optimize this interaction. In a total of 17 sessions, information from the part of ergonomy dealing with human reliability in using technical systems at work was exchanged, and different methods for its evaluation were examined and analyzed. The outcome of this work was systematized and compiled in this book. (orig.) [de

  16. Microelectronics Reliability

    Science.gov (United States)

    2017-01-17

    inverters  connected in a chain. ................................................. 5  Figure 3  Typical graph showing frequency versus square root of...developing an experimental  reliability estimating methodology that could both illuminate the  lifetime  reliability of advanced devices,  circuits and...or  FIT of the device. In other words an accurate estimate of the device  lifetime  was found and thus the  reliability  that  can  be  conveniently

  17. Argon solubility in liquid steel

    NARCIS (Netherlands)

    Boom, R; Dankert, O; Van Veen, A; Kamperman, AA

    2000-01-01

    Experiments have been performed to establish the solubility of argon in liquid interstitial-free steel. The solubility appears to be lower than 0.1 at ppb, The results are in line with argon solubilities reported in the literature on liquid iron. Semiempirical theories and calculations based on the

  18. Experimental studies to validate model calculations and maximum solubility limits for Plutonium and Americium; Experimentelle Arbeiten zur Absicherung von Modellrechnungen und Maximalkonzentrationen fuer Plutonium und Americium

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2017-02-16

    This report focuses on studies of KIT-INE to derive a significantly improved description of the chemical behaviour of Americium and Plutonium in saline NaCl, MgCl{sub 2} and CaCl{sub 2} brine systems. The studies are based on new experimental data and aim at deriving reliable Am and Pu solubility limits for the investigated systems as well as deriving comprehensive thermodynamic model descriptions. Both aspects are of high relevance in the context of potential source term estimations for Americium and Plutonium in aqueous brine systems and related scenarios. Americium and Plutonium are long-lived alpha emitting radionuclides which due to their high radiotoxicity need to be accounted for in a reliable and traceable way. The hydrolysis of trivalent actinides and the effect of highly alkaline pH conditions on the solubility of trivalent actinides in calcium chloride rich brine solutions were investigated and a thermodynamic model derived. The solubility of Plutonium in saline brine systems was studied under reducing and non-reducing conditions and is described within a new thermodynamic model. The influence of dissolved carbonate on Americium and Plutonium solubility in MgCl{sub 2} solutions was investigated and quantitative information on Am and Pu solubility limits in these systems derived. Thermodynamic constants and model parameter derived in this work are implemented in the Thermodynamic Reference Database THEREDA owned by BfS. According to the quality assurance approach in THEREDA, is was necessary to publish parts of this work in peer-reviewed scientific journals. The publications are focused on solubility experiments, spectroscopy of aquatic and solid species and thermodynamic data. (Neck et al., Pure Appl. Chem., Vol. 81, (2009), pp. 1555-1568., Altmaier et al., Radiochimica Acta, 97, (2009), pp. 187-192., Altmaier et al., Actinide Research Quarterly, No 2., (2011), pp. 29-32.).

  19. Oral formulation strategies to improve solubility of poorly water-soluble drugs.

    Science.gov (United States)

    Singh, Abhishek; Worku, Zelalem Ayenew; Van den Mooter, Guy

    2011-10-01

    In the past two decades, there has been a spiraling increase in the complexity and specificity of drug-receptor targets. It is possible to design drugs for these diverse targets with advances in combinatorial chemistry and high throughput screening. Unfortunately, but not entirely unexpectedly, these advances have been accompanied by an increase in the structural complexity and a decrease in the solubility of the active pharmaceutical ingredient. Therefore, the importance of formulation strategies to improve the solubility of poorly water-soluble drugs is inevitable, thus making it crucial to understand and explore the recent trends. Drug delivery systems (DDS), such as solid dispersions, soluble complexes, self-emulsifying drug delivery systems (SEDDS), nanocrystals and mesoporous inorganic carriers, are discussed briefly in this review, along with examples of marketed products. This article provides the reader with a concise overview of currently relevant formulation strategies and proposes anticipated future trends. Today, the pharmaceutical industry has at its disposal a series of reliable and scalable formulation strategies for poorly soluble drugs. However, due to a lack of understanding of the basic physical chemistry behind these strategies, formulation development is still driven by trial and error.

  20. Intrinsic solubility estimation and pH-solubility behavior of cosalane (NSC 658586), an extremely hydrophobic diprotic acid.

    Science.gov (United States)

    Venkatesh, S; Li, J; Xu, Y; Vishnuvajjala, R; Anderson, B D

    1996-10-01

    The selection of cosalane (NSC 658586) by the National Cancer Institute for further development as a potential drug candidate for the treatment of AIDS led to the exploration of the solubility behavior of this extremely hydrophobic drug, which has an intrinsic solubility (S0 approaching 1 ng/ml. This study describes attempts to reliably measure the intrinsic solubility of cosalane and examine its pH-solubility behavior. S0 was estimated by 5 different strategies: (a) direct determination in an aqueous suspension: (b) facilitated dissolution; (c) estimation from the octanol/water partition coefficient and octanol solubility (d) application of an empirical equation based on melting point and partition coefficient; and (e) estimation from the hydrocarbon solubility and functional group contributions for transfer from hydrocarbon to water. S0 estimates using these five methods varied over a 5 x 107-fold range Method (a) yielded the highest values, two-orders of magnitude greater than those obtained by method (b) (facilitated dissolution. 1.4 +/- 0.5 ng/ml). Method (c) gave a value 20-fold higher while that from method (d) was in fair agreement with that from facilitated dissolution. Method (e) yielded a value several orders-of-magnitude lower than other methods. A molecular dynamics simulation suggests that folded conformations not accounted for by group contributions may reduce cosalane's effective hydrophobicity. Ionic equilibria calculations for this weak diprotic acid suggested a 100-fold increase in solubility per pH unit increase. The pH-solubility profile of cosalane at 25 degrees C agreed closely with theory. These studies highlight the difficulty in determining solubility of very poorly soluble compounds and the possible advantage of the facilitated dissolution method. The diprotic nature of cosalane enabled a solubility enhancement of > 107-fold by simple pH adjustment.

  1. Soluble porphyrin polymers

    Science.gov (United States)

    Gust, Jr., John Devens; Liddell, Paul Anthony

    2015-07-07

    Porphyrin polymers of Structure 1, where n is an integer (e.g., 1, 2, 3, 4, 5, or greater) ##STR00001## are synthesized by the method shown in FIGS. 2A and 2B. The porphyrin polymers of Structure 1 are soluble in organic solvents such as 2-MeTHF and the like, and can be synthesized in bulk (i.e., in processes other than electropolymerization). These porphyrin polymers have long excited state lifetimes, making the material suitable as an organic semiconductor for organic electronic devices including transistors and memories, as well as solar cells, sensors, light-emitting devices, and other opto-electronic devices.

  2. A novel multi-walled carbon nanotube-based antibody conjugate for quantitative and semi-quantitative lateral flow assays.

    Science.gov (United States)

    Sun, Wenjuan; Hu, Xiaolong; Liu, Jia; Zhang, Yurong; Lu, Jianzhong; Zeng, Libo

    2017-10-01

    In this study, the multi-walled carbon nanotubes (MWCNTs) were applied in lateral flow strips (LFS) for semi-quantitative and quantitative assays. Firstly, the solubility of MWCNTs was improved using various surfactants to enhance their biocompatibility for practical application. The dispersed MWCNTs were conjugated with the methamphetamine (MET) antibody in a non-covalent manner and then manufactured into the LFS for the quantitative detection of MET. The MWCNTs-based lateral flow assay (MWCNTs-LFA) exhibited an excellent linear relationship between the values of test line and MET when its concentration ranges from 62.5 to 1500 ng/mL. The sensitivity of the LFS was evaluated by conjugating MWCNTs with HCG antibody and the MWCNTs conjugated method is 10 times more sensitive than the one conjugated with classical colloidal gold nanoparticles. Taken together, our data demonstrate that MWCNTs-LFA is a more sensitive and reliable assay for semi-quantitative and quantitative detection which can be used in forensic analysis.

  3. Redefining reliability

    International Nuclear Information System (INIS)

    Paulson, S.L.

    1995-01-01

    Want to buy some reliability? The question would have been unthinkable in some markets served by the natural gas business even a few years ago, but in the new gas marketplace, industrial, commercial and even some residential customers have the opportunity to choose from among an array of options about the kind of natural gas service they need--and are willing to pay for. The complexities of this brave new world of restructuring and competition have sent the industry scrambling to find ways to educate and inform its customers about the increased responsibility they will have in determining the level of gas reliability they choose. This article discusses the new options and the new responsibilities of customers, the needed for continuous education, and MidAmerican Energy Company's experiment in direct marketing of natural gas

  4. Radiochemical investigations on the solubility of molybdatophosphate in phosphate determination

    International Nuclear Information System (INIS)

    Noack, S.

    1975-01-01

    The solubility of various molybdatophosphates was determined under the conditions of a gravimetric phosphate determination by radiochemical means by labelling PO 4 3- with P-32. Starting with various conditions for phosphate determination via the molybdatophosphate of quinoline, 8-hydroxyquinoline, dimorpholino ethane, N,N,N',N'-tetrakis-β-hydroxypropyl ethylene diamine and N,N,N',N'-tetrakis-β-hydroxybutyl ethylene diamine, a general working rule was developed to determine the solubility. Taking the example of quinoline molybdatophosphates, a series of influencing factors - work, concentration and measuring parameters - were investigated in order to be able to limit the reliability region of the gravimetric phosphate determination. Depending on the conditions, the measured solubilities were between 10 -10 and 10 -6 Mol/l, the corresponding degrees of precipitation between 99.0 and 99.9999%. Apparent solubility products were calculated for the different molybdatophosphates using computer programmes especially developed for this purpose. (orig./RB) [de

  5. Waste package reliability analysis

    International Nuclear Information System (INIS)

    Pescatore, C.; Sastre, C.

    1983-01-01

    Proof of future performance of a complex system such as a high-level nuclear waste package over a period of hundreds to thousands of years cannot be had in the ordinary sense of the word. The general method of probabilistic reliability analysis could provide an acceptable framework to identify, organize, and convey the information necessary to satisfy the criterion of reasonable assurance of waste package performance according to the regulatory requirements set forth in 10 CFR 60. General principles which may be used to evaluate the qualitative and quantitative reliability of a waste package design are indicated and illustrated with a sample calculation of a repository concept in basalt. 8 references, 1 table

  6. Influencing the solubility of oxalates for the preparation of ceramic powders from mixed precipitates

    International Nuclear Information System (INIS)

    Krueger, C.; Fischer, S.; Fischer, St.; Chebani, M.Kh.

    1991-01-01

    Based on investigations of the solubility of oxalate with 140 Ba, 64 Cu and 59 Fe, techniques for quantitative oxalate coprecipitation were developed. Addition of organic solvents lowers the solubility and leads to a smaller particle size of products. (orig.) [de

  7. Human reliability in complex systems: an overview

    International Nuclear Information System (INIS)

    Embrey, D.E.

    1976-07-01

    A detailed analysis is presented of the main conceptual background underlying the areas of human reliability and human error. The concept of error is examined and generalized to that of human reliability, and some of the practical and methodological difficulties of reconciling the different standpoints of the human factors specialist and the engineer discussed. Following a survey of general reviews available on human reliability, quantitative techniques for prediction of human reliability are considered. An in-depth critical analysis of the various quantitative methods is then presented, together with the data bank requirements for human reliability prediction. Reliability considerations in process control and nuclear plant, and also areas of design, maintenance, testing and emergency situations are discussed. The effects of stress on human reliability are analysed and methods of minimizing these effects discussed. Finally, a summary is presented and proposals for further research are set out. (author)

  8. An Introduction To Reliability

    International Nuclear Information System (INIS)

    Park, Kyoung Su

    1993-08-01

    This book introduces reliability with definition of reliability, requirement of reliability, system of life cycle and reliability, reliability and failure rate such as summary, reliability characteristic, chance failure, failure rate which changes over time, failure mode, replacement, reliability in engineering design, reliability test over assumption of failure rate, and drawing of reliability data, prediction of system reliability, conservation of system, failure such as summary and failure relay and analysis of system safety.

  9. On the americium oxalate solubility

    International Nuclear Information System (INIS)

    Zakolupin, S.A.; Korablin, Eh.V.

    1977-01-01

    The americium oxalate solubility at different nitric (0.0-1 M) and oxalic (0.0-0.4 M) acid concentrations was investigated in the temperature range from 14 to 60 deg C. The dependence of americium oxalate solubility on the oxalic acid concentration was determined. Increasing oxalic acid concentration was found to reduce the americium oxalate solubility. The dependence of americium oxalate solubility on the oxalic acid concentration was noted to be a minimum at low acidity (0.1-0.3 M nitric acid). This is most likely due to Am(C 2 O 4 ) + , Am(C 2 O 4 ) 2 - and Am(C 2 O 4 ) 3 3- complex ion formation which have different unstability constants. On the basis of the data obtained, a preliminary estimate was carried out for the product of americium oxalate solubility in nitric acid medium (10 -29 -10 -31 ) and of the one in water (6.4x10 -20 )

  10. Comparison of leaf gas exchange and stable isotope signature of water-soluble compounds along canopy gradients of co-occurring Douglas-fir and European beech.

    Science.gov (United States)

    Bögelein, Rebekka; Hassdenteufel, Martin; Thomas, Frank M; Werner, Willy

    2012-07-01

    Combined δ(13) C and δ(18) O analyses of water-soluble leaf and twig phloem material were used to determine intrinsic water-use efficiency (iWUE) and variability of stomatal conductance at different crown positions in adult European beech (Fagus sylvatica) and Douglas-fir (Pseudotsuga menziesii) trees. Simultaneous gas exchange measurements allowed evaluation of the differences in calculating iWUE from leaf or phloem water-soluble compounds, and comparison with a semi-quantitative dual isotope model to infer variability of net photosynthesis (A(n) ) between the investigated crown positions. Estimates of iWUE from δ(13) C of leaf water-soluble organic matter (WSOM) outperformed the estimates from phloem compounds. In the beech crown, δ(13) C of leaf WSOM coincided clearly with gas exchange measurements. The relationship was not as reliable in the Douglas-fir. The differences in δ(18) O between leaf and phloem material were found to correlate with stomatal conductance. The semi-quantitative model approach was applicable for comparisons of daily average A(n) between different crown positions and trees. Intracanopy gradients were more pronounced in the beech than in the Douglas-fir, which reached higher values of iWUE at the respective positions, particularly under dry air conditions. © 2012 Blackwell Publishing Ltd.

  11. Uranium solubility and solubility controls in selected Needle's Eye groundwaters

    International Nuclear Information System (INIS)

    Falck, W.E.; Hooker, P.J.

    1991-01-01

    The solubility control of uranium in selected groundwater samples from the cliff and sediments at the Needle's Eye natural analogue site is investigated using the speciation code PHREEQE and the CHEMVAL thermodynamic database (release 3). Alkali-earth bearing uranyl carbonate secondary minerals are likely to exert influence on the solubility . Other candidates are UO 2 and arsenates, depending on the prevailing redox conditions. In the absence of literature data, solubility products for important arsenates have been estimated from analogy with other arsenates and phosphates. Phosphates themselves are unlikely to exert control owing to their comparatively high solubilities. The influence of seawater flooding into the sediments is also discussed. The importance of uranyl arsenates in the retardation of uranium in shallow sediments has been demonstrated in theory, but there are some significant gaps in the thermodynamic databases used. (author)

  12. Noble gases solubility in water

    International Nuclear Information System (INIS)

    Crovetto, Rosa; Fernandez Prini, Roberto.

    1980-07-01

    The available experimental data of solubility of noble gases in water for temperatures smaller than 330 0 C have been critically surveyed. Due to the unique structure of the solvent, the solubility of noble gases in water decreases with temperature passing through a temperature of minimum solubility which is different for each gas, and then increases at higher temperatures. As aresult of the analysis of the experimental data and of the features of the solute-solvent interaction, a generalized equation is proposed which enables thecalculation of Henry's coefficient at different temperatures for all noble gases. (author) [es

  13. Reliability engineering: Old problems and new challenges

    International Nuclear Information System (INIS)

    Zio, E.

    2009-01-01

    The first recorded usage of the word reliability dates back to the 1800s, albeit referred to a person and not a technical system. Since then, the concept of reliability has become a pervasive attribute worth of both qualitative and quantitative connotations. In particular, the revolutionary social, cultural and technological changes that have occurred from the 1800s to the 2000s have contributed to the need for a rational framework and quantitative treatment of the reliability of engineered systems and plants. This has led to the rise of reliability engineering as a scientific discipline. In this paper, some considerations are shared with respect to a number of problems and challenges which researchers and practitioners in reliability engineering are facing when analyzing today's complex systems. The focus will be on the contribution of reliability to system safety and on its role within system risk analysis

  14. Frontiers of reliability

    CERN Document Server

    Basu, Asit P; Basu, Sujit K

    1998-01-01

    This volume presents recent results in reliability theory by leading experts in the world. It will prove valuable for researchers, and users of reliability theory. It consists of refereed invited papers on a broad spectrum of topics in reliability. The subjects covered include Bayesian reliability, Bayesian reliability modeling, confounding in a series system, DF tests, Edgeworth approximation to reliability, estimation under random censoring, fault tree reduction for reliability, inference about changes in hazard rates, information theory and reliability, mixture experiment, mixture of Weibul

  15. Probabilistic risk assessment course documentation. Volume 3. System reliability and analysis techniques, Session A - reliability

    International Nuclear Information System (INIS)

    Lofgren, E.V.

    1985-08-01

    This course in System Reliability and Analysis Techniques focuses on the quantitative estimation of reliability at the systems level. Various methods are reviewed, but the structure provided by the fault tree method is used as the basis for system reliability estimates. The principles of fault tree analysis are briefly reviewed. Contributors to system unreliability and unavailability are reviewed, models are given for quantitative evaluation, and the requirements for both generic and plant-specific data are discussed. Also covered are issues of quantifying component faults that relate to the systems context in which the components are embedded. All reliability terms are carefully defined. 44 figs., 22 tabs

  16. Deterministic quantitative risk assessment development

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, Jane; Colquhoun, Iain [PII Pipeline Solutions Business of GE Oil and Gas, Cramlington Northumberland (United Kingdom)

    2009-07-01

    Current risk assessment practice in pipeline integrity management is to use a semi-quantitative index-based or model based methodology. This approach has been found to be very flexible and provide useful results for identifying high risk areas and for prioritizing physical integrity assessments. However, as pipeline operators progressively adopt an operating strategy of continual risk reduction with a view to minimizing total expenditures within safety, environmental, and reliability constraints, the need for quantitative assessments of risk levels is becoming evident. Whereas reliability based quantitative risk assessments can be and are routinely carried out on a site-specific basis, they require significant amounts of quantitative data for the results to be meaningful. This need for detailed and reliable data tends to make these methods unwieldy for system-wide risk k assessment applications. This paper describes methods for estimating risk quantitatively through the calibration of semi-quantitative estimates to failure rates for peer pipeline systems. The methods involve the analysis of the failure rate distribution, and techniques for mapping the rate to the distribution of likelihoods available from currently available semi-quantitative programs. By applying point value probabilities to the failure rates, deterministic quantitative risk assessment (QRA) provides greater rigor and objectivity than can usually be achieved through the implementation of semi-quantitative risk assessment results. The method permits a fully quantitative approach or a mixture of QRA and semi-QRA to suit the operator's data availability and quality, and analysis needs. For example, consequence analysis can be quantitative or can address qualitative ranges for consequence categories. Likewise, failure likelihoods can be output as classical probabilities or as expected failure frequencies as required. (author)

  17. Quantitative Risks

    Science.gov (United States)

    2015-02-24

    design failure modes and effects analysis (DFMEA), (b) Fault Tree Analysis ( FTA ) for all essential functions listed in the Failure Definition and...subsystem reliability date from Accomplishment 3, completed (a) updated DFMEA, (b) updated FTA , (c) updated reliability and maintainability estimates, (d...www.gao.gov/assets/660/658615.pdf [4] Karen Richey. Update to GAO’s Cost Estimating Assessment Guide and Scheduling Guide (draft). GAO. Mar 2013

  18. System Reliability Engineering

    International Nuclear Information System (INIS)

    Lim, Tae Jin

    2005-02-01

    This book tells of reliability engineering, which includes quality and reliability, reliability data, importance of reliability engineering, reliability and measure, the poisson process like goodness of fit test and the poisson arrival model, reliability estimation like exponential distribution, reliability of systems, availability, preventive maintenance such as replacement policies, minimal repair policy, shock models, spares, group maintenance and periodic inspection, analysis of common cause failure, and analysis model of repair effect.

  19. Solubility is the most important mass transfer factor

    International Nuclear Information System (INIS)

    Slobodov, A.A.; Zarembo, V.I.

    1992-01-01

    The existence of the quantitative correlation between mass transfer and equilibrium solubility of corrosion products of construction materials in water circuits of power plants is shown. Thermodynamic and mathematical methods of modeling and calculating for these processes are developed. The results for iron based materials - aqueous solution systems in a wide range of temperature, pH, oxygen-hydrogen concentrations are presented. The optimization conditions for mass transfer, sedimentation of corrosion products for BWR, PWR reactors, etc. have been obtained

  20. On nitrogen solubility in water

    International Nuclear Information System (INIS)

    Kalajda, Yu.A.; Katkov, Yu.D.; Kuznetsov, V.A.; Lastovtsev, A.Yu.; Lastochkin, A.P.; Susoev, V.S.

    1980-01-01

    Presented are the results of experimental investigations on nitrogen solubility in water under 0-15 MPa pressure, at the temperature of 100-340 deg C and nitrogen concentration of 0-5000 n.ml. N 2 /kg H 2 O. Empiric equations are derived and a diagram of nitrogen solubility in water is developed on the basis of the experimental data, as well as critically evaluated published data. The investigation results can be used in analyzing water-gas regime of a primary heat carrier in stream-generating plants with water-water reactors

  1. Preliminary considerations concerning actinide solubilities

    International Nuclear Information System (INIS)

    Newton, T.W.; Bayhurst, B.P.; Daniels, W.R.; Erdal, B.R.; Ogard, A.E.

    1980-01-01

    Work at the Los Alamos Scientific Laboratory on the fundamental solution chemistry of the actinides has thus far been confined to preliminary considerations of the problems involved in developing an understanding of the precipitation and dissolution behavior of actinide compounds under environmental conditions. Attempts have been made to calculate solubility as a function of Eh and pH using the appropriate thermodynamic data; results have been presented in terms of contour maps showing lines of constant solubility as a function of Eh and pH. Possible methods of control of the redox potential of rock-groundwater systems by the use of Eh buffers (redox couples) is presented

  2. Thorium oxalate solubility and morphology

    International Nuclear Information System (INIS)

    Monson, P.R. Jr.; Hall, R.

    1981-10-01

    Thorium was used as a stand-in for studying the solubility and precipitation of neptunium and plutonium oxalates. Thorium oxalate solubility was determined over a range of 0.001 to 10.0 in the concentration parameter [H 2 C 2 O 4 ]/[HNO 3 ] 2 . Morphology of thorium oxide made from the oxalate precipitates was characterized by scanning electron microscopy. The different morphologies found for oxalate-lean and oxalate-rich precipitations were in agreement with predictions based on precipitation theory

  3. Solubility database for TILA-99

    Energy Technology Data Exchange (ETDEWEB)

    Vuorinen, U.; Carlsson, T. [VTT Chemical Technology, Espoo (Finland); Kulmala, S.; Hakanen, M. [Helsinki Univ. (Finland). Lab. of Radiochemistry; Ahonen, L. [Geological Survey of Finland, Espoo (Finland)

    1998-11-01

    The safety assessment of spent fuel disposal requires solubility values for several elements estimated in Finnish disposal conditions. In Finland four sites (Haestholmen, Kivetty, Olkiluoto and Romuvaara) are investigated for the disposal of spent fuel. Haestholmen and OLkiluoto are onshore sites, while Kivetty and Romuvaara are inland sites. Based on groundwater analysis and classification according to salinity at the planned disposal depth mainly fresh groundwater is encountered at Kivetty and Romuvaara, while brackish and saline water-types are met at Haestholmen and Olkiluoto. Very saline, almost brine-type water ({approx}70 g/l) has been found in the deepest parts of the investigated bedrock at one of the sites (Olkiluoto). The reference waters and conditions were chosen according to the water-types. The considered reference conditions incorporated both the near- and far-field, and both oxidizing and reducing conditions were considered. In the reference conditions, the changes in solubilities were also estimated as caused by possible variations in the pH, carbonate content and redox conditions. Uranium, which is the main component of spent fuel is dealt with in a separate report presenting the solubility of uranium and spent fuel dissolution. In this work the solubilities of all the other elements of concern (Am, Cu, Nb, Np, Pa, Pd, Pu, Ra, Se, Sn, Tc, Zr, Cm, Ni, Sr, Th, C, Cl, Cs, Fe, Ho, I, and Sm) in the safety assessment are considered. Some discussion on the corrosion of the spent fuel canister is also presented. For the estimation of solubilities of the elements in question, literature data was collected that mainly comprised experimentally measured concentrations. The sources used were spent fuel experiments, concentrations measured in solubility measurements, natural concentrations and concentrations from natural analogue sites (especially Palmottu and Hyrkkoelae in Finland) as well as the concentrations measured at the Finnish investigation sites

  4. Solubility database for TILA-99

    International Nuclear Information System (INIS)

    Vuorinen, U.; Carlsson, T.; Kulmala, S.; Hakanen, M.

    1998-11-01

    The safety assessment of spent fuel disposal requires solubility values for several elements estimated in Finnish disposal conditions. In Finland four sites (Haestholmen, Kivetty, Olkiluoto and Romuvaara) are investigated for the disposal of spent fuel. Haestholmen and OLkiluoto are onshore sites, while Kivetty and Romuvaara are inland sites. Based on groundwater analysis and classification according to salinity at the planned disposal depth mainly fresh groundwater is encountered at Kivetty and Romuvaara, while brackish and saline water-types are met at Haestholmen and Olkiluoto. Very saline, almost brine-type water (∼70 g/l) has been found in the deepest parts of the investigated bedrock at one of the sites (Olkiluoto). The reference waters and conditions were chosen according to the water-types. The considered reference conditions incorporated both the near- and far-field, and both oxidizing and reducing conditions were considered. In the reference conditions, the changes in solubilities were also estimated as caused by possible variations in the pH, carbonate content and redox conditions. Uranium, which is the main component of spent fuel is dealt with in a separate report presenting the solubility of uranium and spent fuel dissolution. In this work the solubilities of all the other elements of concern (Am, Cu, Nb, Np, Pa, Pd, Pu, Ra, Se, Sn, Tc, Zr, Cm, Ni, Sr, Th, C, Cl, Cs, Fe, Ho, I, and Sm) in the safety assessment are considered. Some discussion on the corrosion of the spent fuel canister is also presented. For the estimation of solubilities of the elements in question, literature data was collected that mainly comprised experimentally measured concentrations. The sources used were spent fuel experiments, concentrations measured in solubility measurements, natural concentrations and concentrations from natural analogue sites (especially Palmottu and Hyrkkoelae in Finland) as well as the concentrations measured at the Finnish investigation sites. The

  5. Solubility limits on radionuclide dissolution

    Energy Technology Data Exchange (ETDEWEB)

    Kerrisk, J.F.

    1984-12-31

    This paper examines the effects of solubility in limiting dissolution rates of a number of important radionuclides from spent fuel and high-level waste. Two simple dissolution models were used for calculations that would be characteristics of a Yucca Mountain repository. A saturation-limited dissolution model, in which the water flowing through the repository is assumed to be saturated with each waste element, is very conservative in that it overestimates dissolution rates. A diffusion-limited dissolution model, in which element-dissolution rates are limited by diffusion of waste elements into water flowing past the waste, is more realistic, but it is subject to some uncertainty at this time. Dissolution rates of some elements (Pu, Am, Sn, Th, Zr, Sm) are always limited by solubility. Dissolution rates of other elements (Cs, Tc, Np, Sr, C, I) are never solubility limited; their release would be limited by dissolution of the bulk waste form. Still other elements (U, Cm, Ni, Ra) show solubility-limited dissolution under some conditions. 9 references, 3 tables.

  6. Solubility of Nd in brine

    International Nuclear Information System (INIS)

    Khalili, F.I.; Symeopoulos, V.; Chen, J.F.; Choppin, G.R.

    1994-01-01

    The solubility of Nd(III) has been measured at 23±3 C in a synthetic brine at pcH 6.4, 8.4, 10.4 and 12.4. The brine consisted predominantly of (Na+K)Cl and MgCl 2 with an ionic strength of 7.8 M (9.4 m) a solid compound of Nd(III) at each pcH was assigned from X-ray diffraction patterns. The log values of the experimental solubilities decrease fomr -3 at pcH 6.4 to -5.8 at pcH 8.4; at pcH 10.4 and 12.4 the solubility was below the detection limit of -7.5. The experimental solubility does not follow closely the variation with pcH estimated from modeling of the species in solution in equilibrium with the Nd solid using S.I.T. (orig.)

  7. Quantitative habitability.

    Science.gov (United States)

    Shock, Everett L; Holland, Melanie E

    2007-12-01

    A framework is proposed for a quantitative approach to studying habitability. Considerations of environmental supply and organismal demand of energy lead to the conclusions that power units are most appropriate and that the units for habitability become watts per organism. Extreme and plush environments are revealed to be on a habitability continuum, and extreme environments can be quantified as those where power supply only barely exceeds demand. Strategies for laboratory and field experiments are outlined that would quantify power supplies, power demands, and habitability. An example involving a comparison of various metabolisms pursued by halophiles is shown to be well on the way to a quantitative habitability analysis.

  8. AMSAA Reliability Growth Guide

    National Research Council Canada - National Science Library

    Broemm, William

    2000-01-01

    ... has developed reliability growth methodology for all phases of the process, from planning to tracking to projection. The report presents this methodology and associated reliability growth concepts.

  9. Quantitative research

    DEFF Research Database (Denmark)

    Wigram, Anthony Lewis

    2003-01-01

    possible and desirable. It is not just a type of research done in a laboratory, or by PhD students. Some for of reliable measurement can be applied to many clinical situationsto evaluate the effects of therapy over time, or the difference between clients who receive therapy and those who don't. Evaluating...

  10. Inter- and intra-rater reliability of patellofemoral kinematic and contact area quantification by fast spin echo MRI and correlation with cartilage health by quantitative T1ρ MRI.

    Science.gov (United States)

    Lau, Brian C; Thuillier, Daniel U; Pedoia, Valentina; Chen, Ellison Y; Zhang, Zhihong; Feeley, Brian T; Souza, Richard B

    2016-01-01

    Patellar maltracking is a leading cause of patellofemoral pain syndrome (PFPS). The aim of this study was to determine the inter- and intra-rater reliability of a semi-automated program for magnetic resonance imaging (MRI) based patellofemoral kinematics. Sixteen subjects (10 with PFPS [mean age 32.3; SD 5.2; eight females] and six controls without PFPS 19 [mean age 28.6; SD 2.8; three females]) participated in the study. One set of T2-weighted, fat-saturated fast spin-echo (FSE) MRIs were acquired from each subject in full extension and 30° of knee flexion. MRI including axial T1ρ relaxation time mapping sequences was also performed on each knee. Following image acquisitions, regions of interest for kinematic MRI, and patellar and trochlear cartilage were segmented and quantified with in-house designed spline- based MATLAB semi-automated software. Intraclass Correlations Coefficients (ICC) of calculated kinematic parameters were good to excellent, ICC > 0.8 in patellar flexion, rotation, tilt, and translation (anterior -posterior, medial -lateral, and superior -inferior), and contact area translation. Only patellar tilt in the flexed position and motion from extended to flexed state was significantly different between PFPS and control patients (p=0.002 and p=0.006, respectively). No significant correlations were identified between patellofemoral kinematics and contact area with T1ρ relaxation times. A semi-automated, spline-based kinematic MRI technique for patellofemoral kinematic and contact area quantification is highly reproducible with the potential to help better understand the role of patellofemoral maltracking in PFPS and other knee disorders. Level IV. Published by Elsevier B.V.

  11. Inter- and intra-rater reliability of patellofemoral kinematic and contact area quantification by fast spin echo MRI and correlation with cartilage health by quantitative T1ρ MRI☆

    Science.gov (United States)

    Lau, Brian C.; Thuillier, Daniel U.; Pedoia, Valentina; Chen, Ellison Y.; Zhang, Zhihong; Feeley, Brian T.; Souza, Richard B.

    2016-01-01

    Background Patellar maltracking is a leading cause of patellofemoral pain syndrome (PFPS). The aim of this study was to determine the inter- and intra-rater reliability of a semi-automated program for magnetic resonance imaging (MRI) based patellofemoral kinematics. Methods Sixteen subjects (10 with PFPS [mean age 32.3; SD 5.2; eight females] and six controls without PFPS 19 [mean age 28.6; SD 2.8; three females]) participated in the study. One set of T2-weighted, fat-saturated fast spin-echo (FSE) MRIs were acquired from each subject in full extension and 30° of knee flexion. MRI including axial T1ρ relaxation time mapping sequences was also performed on each knee. Following image acquisitions, regions of interest for kinematic MRI, and patellar and trochlear cartilage were segmented and quantified with in-house designed spline- based MATLAB semi-automated software. Results Intraclass Correlations Coefficients (ICC) of calculated kinematic parameters were good to excellent, ICC > 0.8 in patellar flexion, rotation, tilt, and translation (anterior -posterior, medial -lateral, and superior -inferior), and contact area translation. Only patellar tilt in the flexed position and motion from extended to flexed state was significantly different between PFPS and control patients (p = 0.002 and p = 0.006, respectively). No significant correlations were identified between patellofemoral kinematics and contact area with T1ρ relaxation times. Conclusions A semi-automated, spline-based kinematic MRI technique for patellofemoral kinematic and contact area quantification is highly reproducible with the potential to help better understand the role of patellofemoral maltracking in PFPS and other knee disorders. PMID:26746045

  12. The diagnostic reliability of the quantitative pivot-shift evaluation using an electromagnetic measurement system for anterior cruciate ligament deficiency was superior to those of the accelerometer and iPad image analysis.

    Science.gov (United States)

    Tanaka, Toshikazu; Hoshino, Yuichi; Miyaji, Nobuaki; Ibaragi, Kazuyuki; Nishida, Kyohei; Nishizawa, Yuichiro; Araki, Daisuke; Kanzaki, Noriyuki; Matsushita, Takehiko; Kuroda, Ryosuke

    2017-10-14

    Several non-invasive devices have been developed to obtain quantitative assessment of the pivot-shift test in clinical setting using similar but diverse measurement parameters. However, the clinical usability of those measurements has yet to be closely investigated and compared. The purpose of this study was to compare the diagnostic accuracy of three non-invasive measurement devices for the pivot-shift test. Thirty patients with unilateral anterior cruciate ligament (ACL) injury were enrolled. The pivot-shift test was performed under general anaesthesia. Three devices, an accelerometer system (KiRA), an image analysis iPad application (iPad), and electromagnetic measurement system (EMS), were used simultaneously to provide two parameters, namely tibial acceleration monitored using KiRA and EMS, and tibial translation recorded using iPad and EMS. Side-to-side differences in each parameter and correlation between the measurements were tested, and a receiver-operating characteristic (ROC) curve analysis was conducted to compare their measurement accuracy. Significant side-to-side differences were successfully detected using any of the measurements (all p iPad and the EMS for the translation (r = 0.28; p iPad for tibial acceleration and translation, respectively. Although all three measurements were similarly capable of detecting ACL deficiency, the EMS has the advantage of comprehensive evaluation of the pivot-shift test by evaluating both tibial acceleration and translation with higher accuracy than those of KiRA and iPad. It could be suggested that any of those measurement tools might improve the clinical diagnosis of ACL insufficiency. Diagnostic study of consecutive patients with a universally applied gold standard, Level Ib.

  13. Building and integrating reliability models in a Reliability-Centered-Maintenance approach

    International Nuclear Information System (INIS)

    Verite, B.; Villain, B.; Venturini, V.; Hugonnard, S.; Bryla, P.

    1998-03-01

    Electricite de France (EDF) has recently developed its OMF-Structures method, designed to optimize preventive maintenance of passive structures such as pipes and support, based on risk. In particular, reliability performances of components need to be determined; it is a two-step process, consisting of a qualitative sort followed by a quantitative evaluation, involving two types of models. Initially, degradation models are widely used to exclude some components from the field of preventive maintenance. The reliability of the remaining components is then evaluated by means of quantitative reliability models. The results are then included in a risk indicator that is used to directly optimize preventive maintenance tasks. (author)

  14. Solubility of sparingly soluble drug derivatives of anthranilic acid.

    Science.gov (United States)

    Domańska, Urszula; Pobudkowska, Aneta; Pelczarska, Aleksandra

    2011-03-24

    This work is a continuation of our systematic study of the solubility of pharmaceuticals (Pharms). All substances here are derivatives of anthranilic acid, and have an anti-inflammatory direction of action (niflumic acid, flufenamic acid, and diclofenac sodium). The basic thermal properties of pure Pharms, i.e., melting and glass-transition temperatures as well as the enthalpy of melting, have been measured with the differential scanning microcalorimetry technique (DSC). Molar volumes have been calculated with the Barton group contribution method. The equilibrium mole fraction solubilities of three pharmaceuticals were measured in a range of temperatures from 285 to 355 K in three important solvents for Pharm investigations: water, ethanol, and 1-octanol using a dynamic method and spectroscopic UV-vis method. The experimental solubility data have been correlated by means of the commonly known G(E) equation: the NRTL, with the assumption that the systems studied here have revealed simple eutectic mixtures. pK(a) precise measurement values have been investigated with the Bates-Schwarzenbach spectrophotometric method. © 2011 American Chemical Society

  15. A reliability simulation language for reliability analysis

    International Nuclear Information System (INIS)

    Deans, N.D.; Miller, A.J.; Mann, D.P.

    1986-01-01

    The results of work being undertaken to develop a Reliability Description Language (RDL) which will enable reliability analysts to describe complex reliability problems in a simple, clear and unambiguous way are described. Component and system features can be stated in a formal manner and subsequently used, along with control statements to form a structured program. The program can be compiled and executed on a general-purpose computer or special-purpose simulator. (DG)

  16. Status of solubility data for selected elements (U, Mp, Pu, Am, Te, Ni, and Zr)

    International Nuclear Information System (INIS)

    Moll, H.; Brachmann, A.; Wruck, D.; Palmer, C.

    1997-01-01

    This report is an evaluation of solubility data for U, Np, Pu, Am, Tc, Ni and Zr compounds at ambient and elevated temperatures. We review the status of such data in light of the most recently reported experimental results. The focus is on the solid phases that may control solubilities under expected conditions in and near a potential nuclear waste repository at Yucca Mountain, Nevada. Solubility data or reliable predictions over the temperature range 20 to 150 degrees C will be used in geochemical modeling studies of the Yucca Mountain Project [96PAL

  17. Developing Reliable Life Support for Mars

    Science.gov (United States)

    Jones, Harry W.

    2017-01-01

    A human mission to Mars will require highly reliable life support systems. Mars life support systems may recycle water and oxygen using systems similar to those on the International Space Station (ISS). However, achieving sufficient reliability is less difficult for ISS than it will be for Mars. If an ISS system has a serious failure, it is possible to provide spare parts, or directly supply water or oxygen, or if necessary bring the crew back to Earth. Life support for Mars must be designed, tested, and improved as needed to achieve high demonstrated reliability. A quantitative reliability goal should be established and used to guide development t. The designers should select reliable components and minimize interface and integration problems. In theory a system can achieve the component-limited reliability, but testing often reveal unexpected failures due to design mistakes or flawed components. Testing should extend long enough to detect any unexpected failure modes and to verify the expected reliability. Iterated redesign and retest may be required to achieve the reliability goal. If the reliability is less than required, it may be improved by providing spare components or redundant systems. The number of spares required to achieve a given reliability goal depends on the component failure rate. If the failure rate is under estimated, the number of spares will be insufficient and the system may fail. If the design is likely to have undiscovered design or component problems, it is advisable to use dissimilar redundancy, even though this multiplies the design and development cost. In the ideal case, a human tended closed system operational test should be conducted to gain confidence in operations, maintenance, and repair. The difficulty in achieving high reliability in unproven complex systems may require the use of simpler, more mature, intrinsically higher reliability systems. The limitations of budget, schedule, and technology may suggest accepting lower and

  18. Radionuclide solubility control by solid solutions

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, F.; Klinkenberg, M.; Rozov, K.; Bosbach, D. [Forschungszentrum Juelich GmbH (Germany). Inst. of Energy and Climate Research - Nuclear Waste Management and Reactor Safety (IEK-6); Vinograd, V. [Frankfurt Univ. (Germany). Inst. of Geosciences

    2015-07-01

    The migration of radionuclides in the geosphere is to a large extend controlled by sorption processes onto minerals and colloids. On a molecular level, sorption phenomena involve surface complexation, ion exchange as well as solid solution formation. The formation of solid solutions leads to the structural incorporation of radionuclides in a host structure. Such solid solutions are ubiquitous in natural systems - most minerals in nature are atomistic mixtures of elements rather than pure compounds because their formation leads to a thermodynamically more stable situation compared to the formation of pure compounds. However, due to a lack of reliable data for the expected scenario at close-to equilibrium conditions, solid solution systems have so far not been considered in long-term safety assessments for nuclear waste repositories. In recent years, various solid-solution aqueous solution systems have been studied. Here we present state-of-the art results regarding the formation of (Ra,Ba)SO{sub 4} solid solutions. In some scenarios describing a waste repository system for spent nuclear fuel in crystalline rocks {sup 226}Ra dominates the radiological impact to the environment associated with the potential release of radionuclides from the repository in the future. The solubility of Ra in equilibrium with (Ra,Ba)SO{sub 4} is much lower than the one calculated with RaSO{sub 4} as solubility limiting phase. Especially, the available literature data for the interaction parameter W{sub BaRa}, which describes the non-ideality of the solid solution, vary by about one order of magnitude (Zhu, 2004; Curti et al., 2010). The final {sup 226}Ra concentration in this system is extremely sensitive to the amount of barite, the difference in the solubility products of the end-member phases, and the degree of non-ideality of the solid solution phase. Here, we have enhanced the fundamental understanding regarding (1) the thermodynamics of (Ra,Ba)SO{sub 4} solid solutions and (2) the

  19. Near-field solubility studies

    International Nuclear Information System (INIS)

    Thomason, H.P.; Williams, S.J.

    1992-02-01

    Experimental determinations of the solubilities of americium, plutonium, neptunium, protactinium, thorium, radium, lead, tin, palladium and zirconium are reported. These elements have radioactive isotopes of concern in assessments of radioactive waste disposal. All measurements were made under the highly alkaline conditions typical of the near field of a radioactive waste repository which uses cementitious materials for many of the immobilisation matrices, the backfill and the engineered structures. Low redox potentials, typical of those resulting from the corrosion of iron and steel, were simulated for those elements having more than one accessible oxidation state. The dissolved concentrations of the elements were defined using ultrafiltration. In addition, the corrosion of iron and stainless steel was shown to generate low redox potentials in solution and the solubility of iron(II) at high pH was measured and found to be sufficient for it to act as a redox buffer with respect to neptunium and plutonium. (author)

  20. Quantitative Finance

    Science.gov (United States)

    James, Jessica

    2017-01-01

    Quantitative finance is a field that has risen to prominence over the last few decades. It encompasses the complex models and calculations that value financial contracts, particularly those which reference events in the future, and apply probabilities to these events. While adding greatly to the flexibility of the market available to corporations and investors, it has also been blamed for worsening the impact of financial crises. But what exactly does quantitative finance encompass, and where did these ideas and models originate? We show that the mathematics behind finance and behind games of chance have tracked each other closely over the centuries and that many well-known physicists and mathematicians have contributed to the field.

  1. Reliability analysis of Angra I safety systems

    International Nuclear Information System (INIS)

    Oliveira, L.F.S. de; Soto, J.B.; Maciel, C.C.; Gibelli, S.M.O.; Fleming, P.V.; Arrieta, L.A.

    1980-07-01

    An extensive reliability analysis of some safety systems of Angra I, are presented. The fault tree technique, which has been successfully used in most reliability studies of nuclear safety systems performed to date is employed. Results of a quantitative determination of the unvailability of the accumulator and the containment spray injection systems are presented. These results are also compared to those reported in WASH-1400. (E.G.) [pt

  2. The Solubility Parameters of Ionic Liquids

    Science.gov (United States)

    Marciniak, Andrzej

    2010-01-01

    The Hildebrand’s solubility parameters have been calculated for 18 ionic liquids from the inverse gas chromatography measurements of the activity coefficients at infinite dilution. Retention data were used for the calculation. The solubility parameters are helpful for the prediction of the solubility in the binary solvent mixtures. From the solubility parameters, the standard enthalpies of vaporization of ionic liquids were estimated. PMID:20559495

  3. The Solubility Parameters of Ionic Liquids

    Directory of Open Access Journals (Sweden)

    Andrzej Marciniak

    2010-04-01

    Full Text Available The Hildebrand’s solubility parameters have been calculated for 18 ionic liquids from the inverse gas chromatography measurements of the activity coefficients at infinite dilution. Retention data were used for the calculation. The solubility parameters are helpful for the prediction of the solubility in the binary solvent mixtures. From the solubility parameters, the standard enthalpies of vaporization of ionic liquids were estimated.

  4. Solubility of Carbon in Nanocrystalline -Iron

    OpenAIRE

    Alexander Kirchner; Bernd Kieback

    2012-01-01

    A thermodynamic model for nanocrystalline interstitial alloys is presented. The equilibrium solid solubility of carbon in -iron is calculated for given grain size. Inside the strained nanograins local variation of the carbon content is predicted. Due to the nonlinear relation between strain and solubility, the averaged solubility in the grain interior increases with decreasing grain size. The majority of the global solubility enhancement is due to grain boundary enrichment however. Therefor...

  5. Solubilities of some gases in four immidazolium-based ionic liquids

    International Nuclear Information System (INIS)

    Afzal, Waheed; Liu, Xiangyang; Prausnitz, John M.

    2013-01-01

    Graphical abstract: Experimental apparatus based on the synthetic-volumetric method for measuring solubilities of gases in liquids. Highlights: • We constructed an apparatus for measuring solubilities of sparingly-soluble gases. • We measured solubilities of five gases in four immidazolium-based ionic liquids. • We calculated Henry’s constants for gases in the ionic liquids studied in this work. -- Abstract: The synthetic-volumetric method is used for rapidly measuring solubilities of sparingly-soluble gases in monoethylene glycol and in four ionic liquids. Known molar quantities of solute and solvent are charged into an equilibrium vessel. Measured quantities at equilibrium include: temperature, pressure, quantities of fluids, and volumes of the gas and liquid phases in the equilibrium vessel. These measurements enable calculation of equilibrium compositions using material balances. No sampling or chemical analyses are required. Solubilities are reported for carbon dioxide, krypton, oxygen, and hydrogen in monoethylene glycol, l-n-butyl-3-methylimidazolium tetrafluoroborate [BMIM][BF4], l-n-butyl-3-methylimidazolium hexafluorophosphate [BMIM][PF6], 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [EMIM][Tf 2 N], or 1-ethyl-3-methylimidazolium acetate [EMIM][AC]. Solubilities were measured over the temperature range (298 to 355) K and for pressures up to about 7 MPa using two different pieces of equipment, both based on the volumetric method: a low-pressure glass apparatus and a high-pressure stainless-steel apparatus. Special emphasis is given to experimental reliability to assure consistent data

  6. Reliability data banks

    International Nuclear Information System (INIS)

    Cannon, A.G.; Bendell, A.

    1991-01-01

    Following an introductory chapter on Reliability, what is it, why it is needed, how it is achieved and measured, the principles of reliability data bases and analysis methodologies are the subject of the next two chapters. Achievements due to the development of data banks are mentioned for different industries in the next chapter, FACTS, a comprehensive information system for industrial safety and reliability data collection in process plants are covered next. CREDO, the Central Reliability Data Organization is described in the next chapter and is indexed separately, as is the chapter on DANTE, the fabrication reliability Data analysis system. Reliability data banks at Electricite de France and IAEA's experience in compiling a generic component reliability data base are also separately indexed. The European reliability data system, ERDS, and the development of a large data bank come next. The last three chapters look at 'Reliability data banks, - friend foe or a waste of time'? and future developments. (UK)

  7. Suncor maintenance and reliability

    Energy Technology Data Exchange (ETDEWEB)

    Little, S. [Suncor Energy, Calgary, AB (Canada)

    2006-07-01

    Fleet maintenance and reliability at Suncor Energy was discussed in this presentation, with reference to Suncor Energy's primary and support equipment fleets. This paper also discussed Suncor Energy's maintenance and reliability standard involving people, processes and technology. An organizational maturity chart that graphed organizational learning against organizational performance was illustrated. The presentation also reviewed the maintenance and reliability framework; maintenance reliability model; the process overview of the maintenance and reliability standard; a process flow chart of maintenance strategies and programs; and an asset reliability improvement process flow chart. An example of an improvement initiative was included, with reference to a shovel reliability review; a dipper trip reliability investigation; bucket related failures by type and frequency; root cause analysis of the reliability process; and additional actions taken. Last, the presentation provided a graph of the results of the improvement initiative and presented the key lessons learned. tabs., figs.

  8. Reliability technology and nuclear power

    International Nuclear Information System (INIS)

    Garrick, B.J.; Kaplan, S.

    1976-01-01

    This paper reviews some of the history and status of nuclear reliability and the evolution of this subject from art towards science. It shows that that probability theory is the appropriate and essential mathematical language of this subject. The authors emphasize that it is more useful to view probability not as a $prime$frequency$prime$, i.e., not as the result of a statistical experiment, but rather as a measure of state of confidence or a state of knowledge. They also show that the probabilistic, quantitative approach has a considerable history of application in the electric power industry in the area of power system planning. Finally, the authors show that the decision theory notion of utility provides a point of view from which risks, benefits, safety, and reliability can be viewed in a unified way thus facilitating understanding, comparison, and communication. 29 refs

  9. The Accelerator Reliability Forum

    CERN Document Server

    Lüdeke, Andreas; Giachino, R

    2014-01-01

    A high reliability is a very important goal for most particle accelerators. The biennial Accelerator Reliability Workshop covers topics related to the design and operation of particle accelerators with a high reliability. In order to optimize the over-all reliability of an accelerator one needs to gather information on the reliability of many different subsystems. While a biennial workshop can serve as a platform for the exchange of such information, the authors aimed to provide a further channel to allow for a more timely communication: the Particle Accelerator Reliability Forum [1]. This contribution will describe the forum and advertise it’s usage in the community.

  10. Simultaneous determination of eight water-soluble vitamins in supplemented foods by liquid chromatography.

    Science.gov (United States)

    Zafra-Gómez, Alberto; Garballo, Antonio; Morales, Juan C; García-Ayuso, Luis E

    2006-06-28

    A fast, simple, and reliable method for the isolation and determination of the vitamins thiamin, riboflavin, niacin, pantothenic acid, pyridoxine, folic acid, cyanocobalamin, and ascorbic acid in food samples is proposed. The most relevant advantages of the proposed method are the simultaneous determination of the eight more common vitamins in enriched food products and a reduction of the time required for quantitative extraction, because the method consists merely of the addition of a precipitation solution and centrifugation of the sample. Furthermore, this method saves a substantial amount of reagents as compared with official methods, and minimal sample manipulation is achieved due to the few steps required. The chromatographic separation is carried out on a reverse phase C18 column, and the vitamins are detected at different wavelengths by either fluorescence or UV-visible detection. The proposed method was applied to the determination of water-soluble vitamins in supplemented milk, infant nutrition products, and milk powder certified reference material (CRM 421, BCR) with recoveries ranging from 90 to 100%.

  11. The importance of the accuracy of the experimental data for the prediction of solubility

    Directory of Open Access Journals (Sweden)

    SLAVICA ERIĆ

    2010-04-01

    Full Text Available Aqueous solubility is an important factor influencing several aspects of the pharmacokinetic profile of a drug. Numerous publications present different methodologies for the development of reliable computational models for the prediction of solubility from structure. The quality of such models can be significantly affected by the accuracy of the employed experimental solubility data. In this work, the importance of the accuracy of the experimental solubility data used for model training was investigated. Three data sets were used as training sets – data set 1, containing solubility data collected from various literature sources using a few criteria (n = 319, data set 2, created by substituting 28 values from data set 1 with uniformly determined experimental data from one laboratory (n = 319, and data set 3, created by including 56 additional components, for which the solubility was also determined under uniform conditions in the same laboratory, in the data set 2 (n = 375. The selection of the most significant descriptors was performed by the heuristic method, using one-parameter and multi-parameter analysis. The correlations between the most significant descriptors and solubility were established using multi-linear regression analysis (MLR for all three investigated data sets. Notable differences were observed between the equations corresponding to different data sets, suggesting that models updated with new experimental data need to be additionally optimized. It was successfully shown that the inclusion of uniform experimental data consistently leads to an improvement in the correlation coefficients. These findings contribute to an emerging consensus that improving the reliability of solubility prediction requires the inclusion of many diverse compounds for which solubility was measured under standardized conditions in the data set.

  12. The use of isothermal titration calorimetry to assess the solubility enhancement of simvastatin by a range of surfactants

    International Nuclear Information System (INIS)

    Patel, Rajesh; Buckton, Graham; Gaisford, Simon

    2007-01-01

    Surfactants are commonly used to increase the solubility of poorly water soluble drugs but the interactions between drug and surfactant can be complex and quantitative relationships can be hard to derive. One approach is to quantify the thermodynamics of interaction and relate these parameters to known solubility or dissolution rate enhancement data. Isothermal titration calorimetry (ITC) was used to measure the enthalpy and free energy of transfer of a model drug (simvastatin) to a number of surfactant (SDS, HTAB, SDCH and Brij 35) micelles. These data were then compared with the solubility enhancements determined for each surfactant using HPLC assays. As expected, there was correlation between the free energy of transfer for the drug to each surfactant and the solubility enhancement of that surfactant. Although the data set is limited, the results suggest that ITC screening of a range of surfactants against a poorly water soluble drug may allow the selection of the best potential solubilising surfactants

  13. Human Reliability Program Overview

    Energy Technology Data Exchange (ETDEWEB)

    Bodin, Michael

    2012-09-25

    This presentation covers the high points of the Human Reliability Program, including certification/decertification, critical positions, due process, organizational structure, program components, personnel security, an overview of the US DOE reliability program, retirees and academia, and security program integration.

  14. Power electronics reliability analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Mark A.; Atcitty, Stanley

    2009-12-01

    This report provides the DOE and industry with a general process for analyzing power electronics reliability. The analysis can help with understanding the main causes of failures, downtime, and cost and how to reduce them. One approach is to collect field maintenance data and use it directly to calculate reliability metrics related to each cause. Another approach is to model the functional structure of the equipment using a fault tree to derive system reliability from component reliability. Analysis of a fictitious device demonstrates the latter process. Optimization can use the resulting baseline model to decide how to improve reliability and/or lower costs. It is recommended that both electric utilities and equipment manufacturers make provisions to collect and share data in order to lay the groundwork for improving reliability into the future. Reliability analysis helps guide reliability improvements in hardware and software technology including condition monitoring and prognostics and health management.

  15. Reliability of software

    International Nuclear Information System (INIS)

    Kopetz, H.

    1980-01-01

    Common factors and differences in the reliability of hardware and software; reliability increase by means of methods of software redundancy. Maintenance of software for long term operating behavior. (HP) [de

  16. Reliable Design Versus Trust

    Science.gov (United States)

    Berg, Melanie; LaBel, Kenneth A.

    2016-01-01

    This presentation focuses on reliability and trust for the users portion of the FPGA design flow. It is assumed that the manufacturer prior to hand-off to the user tests FPGA internal components. The objective is to present the challenges of creating reliable and trusted designs. The following will be addressed: What makes a design vulnerable to functional flaws (reliability) or attackers (trust)? What are the challenges for verifying a reliable design versus a trusted design?

  17. Pocket Handbook on Reliability

    Science.gov (United States)

    1975-09-01

    exponencial distributions Weibull distribution, -xtimating reliability, confidence intervals, relia- bility growth, 0. P- curves, Bayesian analysis. 20 A S...introduction for those not familiar with reliability and a good refresher for those who are currently working in the area. LEWIS NERI, CHIEF...includes one or both of the following objectives: a) prediction of the current system reliability, b) projection on the system reliability for someI future

  18. Solubility of the Proteinogenic α-Amino Acids in Water, Ethanol, and Ethanol–Water Mixtures

    Science.gov (United States)

    2018-01-01

    The addition of organic solvents to α-amino acids in aqueous solution could be an effective method in crystallization. We reviewed the available data on the solubility of α-amino acids in water, water–ethanol mixtures, and ethanol at 298.15 K and 0.1 MPa. The solubility of l-alanine, l-proline, l-arginine, l-cysteine, and l-lysine in water and ethanol mixtures and the solubility of l-alanine, l-proline, l-arginine, l-cysteine, l-lysine, l-asparagine, l-glutamine, l-histidine, and l-leucine in pure ethanol systems were measured and are published here for the first time. The impact on the solubility of amino acids that can convert in solution, l-glutamic acid and l-cysteine, was studied. At lower concentrations, only the ninhydrin method and the ultraperfomance liquid chromatography (UPLC) method yield reliable results. In the case of α-amino acids that convert in solution, only the UPLC method was able to discern between the different α-amino acids and yields reliable results. Our results demonstrate that α-amino acids with similar physical structures have similar changes in solubility in mixed water/ethanol mixtures. The solubility of l-tryptophan increased at moderate ethanol concentrations. PMID:29545650

  19. Principles of Bridge Reliability

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle; Nowak, Andrzej S.

    The paper gives a brief introduction to the basic principles of structural reliability theory and its application to bridge engineering. Fundamental concepts like failure probability and reliability index are introduced. Ultimate as well as serviceability limit states for bridges are formulated......, and as an example the reliability profile and a sensitivity analyses for a corroded reinforced concrete bridge is shown....

  20. Reliability in engineering '87

    International Nuclear Information System (INIS)

    Tuma, M.

    1987-01-01

    The participants heard 51 papers dealing with the reliability of engineering products. Two of the papers were incorporated in INIS, namely ''Reliability comparison of two designs of low pressure regeneration of the 1000 MW unit at the Temelin nuclear power plant'' and ''Use of probability analysis of reliability in designing nuclear power facilities.''(J.B.)

  1. Quantitative radiography

    International Nuclear Information System (INIS)

    Brase, J.M.; Martz, H.E.; Waltjen, K.E.; Hurd, R.L.; Wieting, M.G.

    1986-01-01

    Radiographic techniques have been used in nondestructive evaluation primarily to develop qualitative information (i.e., defect detection). This project applies and extends the techniques developed in medical x-ray imaging, particularly computed tomography (CT), to develop quantitative information (both spatial dimensions and material quantities) on the three-dimensional (3D) structure of solids. Accomplishments in FY 86 include (1) improvements in experimental equipment - an improved microfocus system that will give 20-μm resolution and has potential for increased imaging speed, and (2) development of a simple new technique for displaying 3D images so as to clearly show the structure of the object. Image reconstruction and data analysis for a series of synchrotron CT experiments conducted by LLNL's Chemistry Department has begun

  2. Solubility Temperature Dependence Predicted from 2D Structure

    Directory of Open Access Journals (Sweden)

    Alex Avdeef

    2015-12-01

    Full Text Available The objective of the study was to find a computational procedure to normalize solubility data determined at various temperatures (e.g., 10 – 50 oC to values at a “reference” temperature (e.g., 25 °C. A simple procedure was devised to predict enthalpies of solution, ΔHsol, from which the temperature dependence of intrinsic (uncharged form solubility, log S0, could be calculated. As dependent variables, values of ΔHsol at 25 °C were subjected to multiple linear regression (MLR analysis, using melting points (mp and Abraham solvation descriptors. Also, the enthalpy data were subjected to random forest regression (RFR and recursive partition tree (RPT analyses. A total of 626 molecules were examined, drawing on 2040 published solubility values measured at various temperatures, along with 77 direct calori    metric measurements. The three different prediction methods (RFR, RPT, MLR all indicated that the estimated standard deviations in the enthalpy data are 11-15 kJ mol-1, which is concordant with the 10 kJ mol-1 propagation error estimated from solubility measurements (assuming 0.05 log S errors, and consistent with the 7 kJ mol-1 average reproducibility in enthalpy values from interlaboratory replicates. According to the MLR model, higher values of mp, H‑bond acidity, polarizability/dipolarity, and dispersion forces relate to more positive (endothermic enthalpy values. However, molecules that are large and have high H-bond basicity are likely to possess negative (exothermic enthalpies of solution. With log S0 values normalized to 25 oC, it was shown that the interlaboratory average standard deviations in solubility measurement are reduced to 0.06 ‑ 0.17 log unit, with higher errors for the least-soluble druglike molecules. Such improvements in data mining are expected to contribute to more reliable in silico prediction models of solubility for use in drug discovery.

  3. Soluble Non-ammonia Nitrogen in Ruminal and Omasal Digesta of Korean Native Steers Supplemented with Soluble Proteins

    Directory of Open Access Journals (Sweden)

    C. W. Choi

    2012-09-01

    Full Text Available An experiment was conducted to study the effect of soluble protein supplements on concentration of soluble non-ammonia nitrogen (SNAN in the liquid phase of ruminal (RD and omasal digesta (OD of Korean native steers, and to investigate diurnal pattern in SNAN concentration in RD and OD. Three ruminally cannulated Korean native steers in a 3×3 Latin square design consumed a basal diet of rice straw and corn-based concentrate (control, and that supplemented (kg/d DM basis with intact casein (0.24; IC or acid hydrolyzed casein (0.46; AHC. Ruminal digesta was sampled using a vacuum pump, whereas OD was collected using an omasal sampling system at 2.0 h intervals after a morning feeding. The SNAN fractions (free amino acid (AA, peptide and soluble protein in RD and OD were assessed using the ninhydrin assay. Concentrations of free AA and total SNAN in RD were significantly (p<0.05 lower than those in OD. Although free AA concentration was relatively high, mean peptide was quantitatively the most important fraction of total SNAN in both RD and OD, indicating that degradation of peptide to AA rather than hydrolysis of soluble protein to peptide or deamination may be the most limiting step in rumen proteolysis of Korean native steers. Diurnal variation in peptide concentration in OD for the soluble protein supplemented diets during the feeding cycle peaked 2 h post-feeding and decreased thereafter whereas that for the control was relatively constant during the entire feeding cycle. Diurnal variation in peptide concentration was rather similar between RD and OD.

  4. Reliable computer systems.

    Science.gov (United States)

    Wear, L L; Pinkert, J R

    1993-11-01

    In this article, we looked at some decisions that apply to the design of reliable computer systems. We began with a discussion of several terms such as testability, then described some systems that call for highly reliable hardware and software. The article concluded with a discussion of methods that can be used to achieve higher reliability in computer systems. Reliability and fault tolerance in computers probably will continue to grow in importance. As more and more systems are computerized, people will want assurances about the reliability of these systems, and their ability to work properly even when sub-systems fail.

  5. Human factor reliability program

    International Nuclear Information System (INIS)

    Knoblochova, L.

    2017-01-01

    The human factor's reliability program was at Slovenske elektrarne, a.s. (SE) nuclear power plants. introduced as one of the components Initiatives of Excellent Performance in 2011. The initiative's goal was to increase the reliability of both people and facilities, in response to 3 major areas of improvement - Need for improvement of the results, Troubleshooting support, Supporting the achievement of the company's goals. The human agent's reliability program is in practice included: - Tools to prevent human error; - Managerial observation and coaching; - Human factor analysis; -Quick information about the event with a human agent; -Human reliability timeline and performance indicators; - Basic, periodic and extraordinary training in human factor reliability(authors)

  6. Training benefits of research on operator reliability

    International Nuclear Information System (INIS)

    Worledge, D.H.

    1989-01-01

    The purpose of the EPRI Operator Reliability Experiments (ORE) Program is to collect data for use in reliability and safety studies of nuclear power plant operation which more realistically take credit for operator performance in preventing core damage. The three objectives in fulfilling this purpose are: to obtain quantitative/qualitative performance data on operating crew responses in the control room for potential accident sequences by using plant simulators; to test the human cognitive reliability (HCR) correlation; and to develop a data collection analysis procedure. This paper discusses the background to this program, data collection and analysis, and the results of quantitative/qualitative insights stemming from initial work. Special attention is paid to how this program impacts upon simulator use and assessment of simulator fidelity. Attention is also paid to the use of data collection procedures to assist training departments in assessing the quality of their training programs

  7. thermal power stations' reliability evaluation in a hydrothermal system

    African Journals Online (AJOL)

    Dr Obe

    A quantitative tool for the evaluation of thermal power stations reliability in a hydrothermal system is presented. ... (solar power); wind (wind power) and the rest, thermal power and ... probability of a system performing its function adequately for ...

  8. Nanosuspension Technology for Solubilizing Poorly Soluble Drugs

    OpenAIRE

    Deoli Mukesh

    2012-01-01

    Poor water solubility for many drugs and drug candidates remains a major obstacle to their development and clinical application. It is estimated that around 40% of drugs in the pipeline cannot be delivered through the preferred route or in some cases, at all owing to poor water solubility. Conventional formulations to improve solubility suffer from low bioavailability and poor pharmacokinetics, with some carriers rendering systemic toxicities (e.g. Cremophor1 EL). To date, nanoscale systems f...

  9. Reliability analysis of software based safety functions

    International Nuclear Information System (INIS)

    Pulkkinen, U.

    1993-05-01

    The methods applicable in the reliability analysis of software based safety functions are described in the report. Although the safety functions also include other components, the main emphasis in the report is on the reliability analysis of software. The check list type qualitative reliability analysis methods, such as failure mode and effects analysis (FMEA), are described, as well as the software fault tree analysis. The safety analysis based on the Petri nets is discussed. The most essential concepts and models of quantitative software reliability analysis are described. The most common software metrics and their combined use with software reliability models are discussed. The application of software reliability models in PSA is evaluated; it is observed that the recent software reliability models do not produce the estimates needed in PSA directly. As a result from the study some recommendations and conclusions are drawn. The need of formal methods in the analysis and development of software based systems, the applicability of qualitative reliability engineering methods in connection to PSA and the need to make more precise the requirements for software based systems and their analyses in the regulatory guides should be mentioned. (orig.). (46 refs., 13 figs., 1 tab.)

  10. Quantitative Thermochronology

    Science.gov (United States)

    Braun, Jean; van der Beek, Peter; Batt, Geoffrey

    2006-05-01

    Thermochronology, the study of the thermal history of rocks, enables us to quantify the nature and timing of tectonic processes. Quantitative Thermochronology is a robust review of isotopic ages, and presents a range of numerical modeling techniques to allow the physical implications of isotopic age data to be explored. The authors provide analytical, semi-analytical, and numerical solutions to the heat transfer equation in a range of tectonic settings and under varying boundary conditions. They then illustrate their modeling approach built around a large number of case studies. The benefits of different thermochronological techniques are also described. Computer programs on an accompanying website at www.cambridge.org/9780521830577 are introduced through the text and provide a means of solving the heat transport equation in the deforming Earth to predict the ages of rocks and compare them directly to geological and geochronological data. Several short tutorials, with hints and solutions, are also included. Numerous case studies help geologists to interpret age data and relate it to Earth processes Essential background material to aid understanding and using thermochronological data Provides a thorough treatise on numerical modeling of heat transport in the Earth's crust Supported by a website hosting relevant computer programs and colour slides of figures from the book for use in teaching

  11. Soluble theory with massive ghosts

    International Nuclear Information System (INIS)

    Pisarski, R.D.

    1983-01-01

    To investigate the unitarity of asymptotically free, higher-derivative theories, like certain models of quantum gravity, I study a prototype in two space-time dimensions. The prototype is a kind of higher-derivative nonlinear sigma model; it is asymptotically free, exhibits dimensional transmutation, and is soluble in a large-N expansion. The S-matrix elements, constructed from the analytic continuation of the Euclidean Green's functions, conserve probability to approx.O(N -1 ), but violate unitarity at approx.O(N -2 ). The model demonstrates that in higher-derivative theories unitarity, or the lack thereof, cannot be decided without explicit control over the infrared limit. Even so, the results suggest that there may exist some (rather special) asymptotically free, higher-derivative theories which are unitary

  12. Issues concerning the determination of solubility products of sparingly soluble crystalline solids. Solubility of HfO2(cr)

    International Nuclear Information System (INIS)

    Rai, Dhanpat; Kitamura, Akira; Rosso, Kevin M.; Sasaki, Takayuki; Kobayashi, Taishi

    2016-01-01

    Solubility studies were conducted with HfO 2 (cr) solid as a function HCl and ionic strength ranging from 2.0 to 0.004 mol kg -1 . These studies involved (1) using two different amounts of the solid phase, (2) acid washing the bulk solid phase, (3) preheating the solid phase to 1400 C, and (4) heating amorphous HfO 2 (am) suspensions to 90 C to ascertain whether the HfO 2 (am) converts to HfO 2 (cr) and to determine the solubility from the oversaturation direction. Based on the results of these treatments it is concluded that the HfO 2 (cr) contains a small fraction of less crystalline, but not amorphous, material [HfO 2 (lcr)] and this, rather than the HfO 2 (cr), is the solubility-controlling phase in the range of experimental variables investigated in this study. The solubility data are interpreted using both the Pitzer and SIT models and they provide log 10 K 0 values of -(59.75±0.35) and -(59.48±0.41), respectively, for the solubility product of HfO 2 (lcr)[HfO 2 (lcr) + 2H 2 O ↔ Hf 4+ + 4OH - ]. The log 10 of the solubility product of HfO 2 (cr) is estimated to be < -63. The observation of a small fraction of less crystalline higher solubility material is consistent with the general picture that mineral surfaces are often structurally and/or compositionally imperfect leading to a higher solubility than the bulk crystalline solid. This study stresses the urgent need, during interpretation of solubility data, of taking precautions to make certain that the observed solubility behavior for sparingly-soluble solids is assigned to the proper solid phase.

  13. Issues concerning the determination of solubility products of sparingly soluble crystalline solids. Solubility of HfO{sub 2}(cr)

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Dhanpat [Rai Enviro-Chem, LLC, Yachats, OR (United States); Kitamura, Akira [Japan Atomic Energy Agency, Ibaraki (Japan); Rosso, Kevin M. [Pacific Northwest National Laboratory, Richland, WA (United States); Sasaki, Takayuki; Kobayashi, Taishi [Kyoto Univ. (Japan)

    2016-11-01

    Solubility studies were conducted with HfO{sub 2}(cr) solid as a function HCl and ionic strength ranging from 2.0 to 0.004 mol kg{sup -1}. These studies involved (1) using two different amounts of the solid phase, (2) acid washing the bulk solid phase, (3) preheating the solid phase to 1400 C, and (4) heating amorphous HfO{sub 2}(am) suspensions to 90 C to ascertain whether the HfO{sub 2}(am) converts to HfO{sub 2}(cr) and to determine the solubility from the oversaturation direction. Based on the results of these treatments it is concluded that the HfO{sub 2}(cr) contains a small fraction of less crystalline, but not amorphous, material [HfO{sub 2}(lcr)] and this, rather than the HfO{sub 2}(cr), is the solubility-controlling phase in the range of experimental variables investigated in this study. The solubility data are interpreted using both the Pitzer and SIT models and they provide log{sub 10} K{sup 0} values of -(59.75±0.35) and -(59.48±0.41), respectively, for the solubility product of HfO{sub 2}(lcr)[HfO{sub 2}(lcr) + 2H{sub 2}O ↔ Hf{sup 4+} + 4OH{sup -}]. The log{sub 10} of the solubility product of HfO{sub 2}(cr) is estimated to be < -63. The observation of a small fraction of less crystalline higher solubility material is consistent with the general picture that mineral surfaces are often structurally and/or compositionally imperfect leading to a higher solubility than the bulk crystalline solid. This study stresses the urgent need, during interpretation of solubility data, of taking precautions to make certain that the observed solubility behavior for sparingly-soluble solids is assigned to the proper solid phase.

  14. Retrograde curves of solidus and solubility

    International Nuclear Information System (INIS)

    Vasil'ev, M.V.

    1979-01-01

    The investigation was concerned with the constitutional diagrams of the eutectic type with ''retrograde solidus'' and ''retrograde solubility curve'' which must be considered as diagrams with degenerate monotectic transformation. The solidus and the solubility curves form a retrograde curve with a common retrograde point representing the solubility maximum. The two branches of the Aetrograde curve can be described with the aid of two similar equations. Presented are corresponding equations for the Cd-Zn system and shown is the possibility of predicting the run of the solubility curve

  15. Solubility limits of importance to leaching

    International Nuclear Information System (INIS)

    Ogard, A.; Bentley, G.; Bryant, E.; Duffy, C.; Grisham, J.; Norris, E.; Orth, C.; Thomas, K.

    1981-01-01

    The solubilities of some radionuclides, especially rare earths and actinides, may be an important and controlling factor in leaching of waste forms. These solubilities should be measured accurately as a function of pH and not as a part of a multicomponent system. Individual solubilities should be measured as a function of temperature to determine if a kinetic effect is being observed in the data. A negative temperature coefficient of solubility for actinides and rare earths in water would have important consequences for nuclear reactor safety and for the management of nuclear wastes

  16. Testing water-soluble carbohydrate QTL effects in perennial ryegrass (Lolium perenne L.) by marker selection

    NARCIS (Netherlands)

    Turner, L.B.; Farrell, M.; Humphreys, M.O.; Dolstra, O.

    2010-01-01

    Water-soluble carbohydrates (WSC) are an important factor determining the nutritional value of grass forage and development of genetic markers for selection of WSC traits in perennial ryegrass would benefit future breeding programmes. Quantitative trait loci (QTLs) for WSC have been published for an

  17. Polyelectrolyte microcapsules for sustained delivery of water-soluble drugs

    Energy Technology Data Exchange (ETDEWEB)

    Anandhakumar, S.; Debapriya, M. [Department of Materials Engineering, Indian Institute of Science, Bangalore, 560012 (India); Nagaraja, V. [Department of Microbiology and Cell Biology, Indian Institute of Science, Bangalore, 560012 (India); Raichur, Ashok M., E-mail: amr@materials.iisc.ernet.in [Department of Materials Engineering, Indian Institute of Science, Bangalore, 560012 (India)

    2011-03-12

    Polyelectrolyte capsules composed of weak polyelectrolytes are introduced as a simple and efficient system for spontaneous encapsulation of low molecular weight water-soluble drugs. Polyelectrolyte capsules were prepared by layer-by-layer (LbL) assembling of weak polyelectrolytes, poly(allylamine hydrochloride) (PAH) and poly(methacrylic acid) (PMA) on polystyrene sulfonate (PSS) doped CaCO{sub 3} particles followed by core removal with ethylene-diaminetetraacetic acid (EDTA). The loading process was observed by confocal laser scanning microscopy (CLSM) using tetramethylrhodamineisothiocyanate labeled dextran (TRITC-dextran) as a fluorescent probe. The intensity of fluorescent probe inside the capsule decreased with increase in cross-linking time. Ciprofloxacin hydrochloride (a model water-soluble drug) was spontaneously deposited into PAH/PMA capsules and their morphological changes were investigated by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The quantitative study of drug loading was also elucidated which showed that drug loading increased with initial drug concentration, but decreased with increase in pH. The loaded drug was released in a sustained manner for 6 h, which could be further extended by cross-linking the capsule wall. The released drug showed significant antibacterial activity against E. coli. These findings indicate that such capsules can be potential carriers for water-soluble drugs in sustained/controlled drug delivery applications.

  18. Polyelectrolyte microcapsules for sustained delivery of water-soluble drugs

    International Nuclear Information System (INIS)

    Anandhakumar, S.; Debapriya, M.; Nagaraja, V.; Raichur, Ashok M.

    2011-01-01

    Polyelectrolyte capsules composed of weak polyelectrolytes are introduced as a simple and efficient system for spontaneous encapsulation of low molecular weight water-soluble drugs. Polyelectrolyte capsules were prepared by layer-by-layer (LbL) assembling of weak polyelectrolytes, poly(allylamine hydrochloride) (PAH) and poly(methacrylic acid) (PMA) on polystyrene sulfonate (PSS) doped CaCO 3 particles followed by core removal with ethylene-diaminetetraacetic acid (EDTA). The loading process was observed by confocal laser scanning microscopy (CLSM) using tetramethylrhodamineisothiocyanate labeled dextran (TRITC-dextran) as a fluorescent probe. The intensity of fluorescent probe inside the capsule decreased with increase in cross-linking time. Ciprofloxacin hydrochloride (a model water-soluble drug) was spontaneously deposited into PAH/PMA capsules and their morphological changes were investigated by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The quantitative study of drug loading was also elucidated which showed that drug loading increased with initial drug concentration, but decreased with increase in pH. The loaded drug was released in a sustained manner for 6 h, which could be further extended by cross-linking the capsule wall. The released drug showed significant antibacterial activity against E. coli. These findings indicate that such capsules can be potential carriers for water-soluble drugs in sustained/controlled drug delivery applications.

  19. The quantitative Morse theorem

    OpenAIRE

    Loi, Ta Le; Phien, Phan

    2013-01-01

    In this paper, we give a proof of the quantitative Morse theorem stated by {Y. Yomdin} in \\cite{Y1}. The proof is based on the quantitative Sard theorem, the quantitative inverse function theorem and the quantitative Morse lemma.

  20. Reliability and safety engineering

    CERN Document Server

    Verma, Ajit Kumar; Karanki, Durga Rao

    2016-01-01

    Reliability and safety are core issues that must be addressed throughout the life cycle of engineering systems. Reliability and Safety Engineering presents an overview of the basic concepts, together with simple and practical illustrations. The authors present reliability terminology in various engineering fields, viz.,electronics engineering, software engineering, mechanical engineering, structural engineering and power systems engineering. The book describes the latest applications in the area of probabilistic safety assessment, such as technical specification optimization, risk monitoring and risk informed in-service inspection. Reliability and safety studies must, inevitably, deal with uncertainty, so the book includes uncertainty propagation methods: Monte Carlo simulation, fuzzy arithmetic, Dempster-Shafer theory and probability bounds. Reliability and Safety Engineering also highlights advances in system reliability and safety assessment including dynamic system modeling and uncertainty management. Cas...

  1. Human reliability analysis

    International Nuclear Information System (INIS)

    Dougherty, E.M.; Fragola, J.R.

    1988-01-01

    The authors present a treatment of human reliability analysis incorporating an introduction to probabilistic risk assessment for nuclear power generating stations. They treat the subject according to the framework established for general systems theory. Draws upon reliability analysis, psychology, human factors engineering, and statistics, integrating elements of these fields within a systems framework. Provides a history of human reliability analysis, and includes examples of the application of the systems approach

  2. Reliability of electronic systems

    International Nuclear Information System (INIS)

    Roca, Jose L.

    2001-01-01

    Reliability techniques have been developed subsequently as a need of the diverse engineering disciplines, nevertheless they are not few those that think they have been work a lot on reliability before the same word was used in the current context. Military, space and nuclear industries were the first ones that have been involved in this topic, however not only in these environments it is that it has been carried out this small great revolution in benefit of the increase of the reliability figures of the products of those industries, but rather it has extended to the whole industry. The fact of the massive production, characteristic of the current industries, drove four decades ago, to the fall of the reliability of its products, on one hand, because the massively itself and, for other, to the recently discovered and even not stabilized industrial techniques. Industry should be changed according to those two new requirements, creating products of medium complexity and assuring an enough reliability appropriated to production costs and controls. Reliability began to be integral part of the manufactured product. Facing this philosophy, the book describes reliability techniques applied to electronics systems and provides a coherent and rigorous framework for these diverse activities providing a unifying scientific basis for the entire subject. It consists of eight chapters plus a lot of statistical tables and an extensive annotated bibliography. Chapters embrace the following topics: 1- Introduction to Reliability; 2- Basic Mathematical Concepts; 3- Catastrophic Failure Models; 4-Parametric Failure Models; 5- Systems Reliability; 6- Reliability in Design and Project; 7- Reliability Tests; 8- Software Reliability. This book is in Spanish language and has a potentially diverse audience as a text book from academic to industrial courses. (author)

  3. An approach for assessing human decision reliability

    International Nuclear Information System (INIS)

    Pyy, P.

    2000-01-01

    This paper presents a method to study human reliability in decision situations related to nuclear power plant disturbances. Decisions often play a significant role in handling of emergency situations. The method may be applied to probabilistic safety assessments (PSAs) in cases where decision making is an important dimension of an accident sequence. Such situations are frequent e.g. in accident management. In this paper, a modelling approach for decision reliability studies is first proposed. Then, a case study with two decision situations with relatively different characteristics is presented. Qualitative and quantitative findings of the study are discussed. In very simple decision cases with time pressure, time reliability correlation proved out to be a feasible reliability modelling method. In all other decision situations, more advanced probabilistic decision models have to be used. Finally, decision probability assessment by using simulator run results and expert judgement is presented

  4. ESCAF - Failure simulation and reliability calculation device

    International Nuclear Information System (INIS)

    Laviron, A.; Berard, C.; Quenee, R.

    1979-01-01

    Reliability studies of nuclear power plant safety functions have, up to now, required the use of large computers. As they are of universal use, these big machines are not very well adapted to deal with reliability problems at low cost. ESCAF has been developed to be substituted for large computers in order to save time and money. ESCAF is a small electronic device which can be used in connection with a minicomputer. It allows to perform complex system reliability analysis (qualitative and quantitative) and to study critical element influences such as common cause failures. In this paper, the device is described and its features and abilities are outlined: easy to implement, swift running, low working cost. Its application range concerns all cases when a good reliability is needed

  5. Weibull distribution in reliability data analysis in nuclear power plant

    International Nuclear Information System (INIS)

    Ma Yingfei; Zhang Zhijian; Zhang Min; Zheng Gangyang

    2015-01-01

    Reliability is an important issue affecting each stage of the life cycle ranging from birth to death of a product or a system. The reliability engineering includes the equipment failure data processing, quantitative assessment of system reliability and maintenance, etc. Reliability data refers to the variety of data that describe the reliability of system or component during its operation. These data may be in the form of numbers, graphics, symbols, texts and curves. Quantitative reliability assessment is the task of the reliability data analysis. It provides the information related to preventing, detect, and correct the defects of the reliability design. Reliability data analysis under proceed with the various stages of product life cycle and reliability activities. Reliability data of Systems Structures and Components (SSCs) in Nuclear Power Plants is the key factor of probabilistic safety assessment (PSA); reliability centered maintenance and life cycle management. The Weibull distribution is widely used in reliability engineering, failure analysis, industrial engineering to represent manufacturing and delivery times. It is commonly used to model time to fail, time to repair and material strength. In this paper, an improved Weibull distribution is introduced to analyze the reliability data of the SSCs in Nuclear Power Plants. An example is given in the paper to present the result of the new method. The Weibull distribution of mechanical equipment for reliability data fitting ability is very strong in nuclear power plant. It's a widely used mathematical model for reliability analysis. The current commonly used methods are two-parameter and three-parameter Weibull distribution. Through comparison and analysis, the three-parameter Weibull distribution fits the data better. It can reflect the reliability characteristics of the equipment and it is more realistic to the actual situation. (author)

  6. A reliability evaluation method for NPP safety DCS application software

    International Nuclear Information System (INIS)

    Li Yunjian; Zhang Lei; Liu Yuan

    2014-01-01

    In the field of nuclear power plant (NPP) digital i and c application, reliability evaluation for safety DCS application software is a key obstacle to be removed. In order to quantitatively evaluate reliability of NPP safety DCS application software, this paper propose a reliability evaluating method based on software development life cycle every stage's v and v defects density characteristics, by which the operating reliability level of the software can be predicted before its delivery, and helps to improve the reliability of NPP safety important software. (authors)

  7. Operational safety reliability research

    International Nuclear Information System (INIS)

    Hall, R.E.; Boccio, J.L.

    1986-01-01

    Operating reactor events such as the TMI accident and the Salem automatic-trip failures raised the concern that during a plant's operating lifetime the reliability of systems could degrade from the design level that was considered in the licensing process. To address this concern, NRC is sponsoring the Operational Safety Reliability Research project. The objectives of this project are to identify the essential tasks of a reliability program and to evaluate the effectiveness and attributes of such a reliability program applicable to maintaining an acceptable level of safety during the operating lifetime at the plant

  8. Circuit design for reliability

    CERN Document Server

    Cao, Yu; Wirth, Gilson

    2015-01-01

    This book presents physical understanding, modeling and simulation, on-chip characterization, layout solutions, and design techniques that are effective to enhance the reliability of various circuit units.  The authors provide readers with techniques for state of the art and future technologies, ranging from technology modeling, fault detection and analysis, circuit hardening, and reliability management. Provides comprehensive review on various reliability mechanisms at sub-45nm nodes; Describes practical modeling and characterization techniques for reliability; Includes thorough presentation of robust design techniques for major VLSI design units; Promotes physical understanding with first-principle simulations.

  9. Soluble FLT-1 rules placental destiny.

    Science.gov (United States)

    Yamashita, Michiko; Kumasawa, Keiichi; Nakamura, Hitomi; Kimura, Tadashi

    2018-02-19

    Placenta previa is an abnormality in which the placenta covers the internal uterine os, and it can cause serious morbidity and mortality in both mother and fetus due to catastrophic hemorrhage. Some pregnant women recover from placenta previa due to a phenomenon called "migration." However, the mechanism of "migration" of the placenta has not been elucidated. Human placentas were collected from patients with placenta previa and those with no abnormal placentation (control). A microarray analysis was performed to detect the genes up- or down-regulated only in the caudal part in the previa group. Specific mRNA expression was evaluated using real-time quantitative reverse transcription PCR (qRT-PCR). Unilateral uterine artery ablation of 8.5 dpc mice was performed to reproduce the reduction of placental blood supply, and weights of the placentas and fetuses were evaluated in 18.5 dpc. Specific mRNA expression was also evaluated in mice placentas. According to the result of the microarray analysis, we focused on soluble fms-like tyrosine kinase-1 (sFLT-1) and hypoxia-inducible factor-1 (HIF-1) alpha. The sFLT-1 expression level is locally high in the caudal part of the human placenta in patients with placenta previa. In mice experiments, the weights of the placentas and fetuses were significantly smaller in the ablation side than those in the control side, and the sFlt-1 expression level was significantly higher in the ablation side than in the control side. Our study suggests that "migration" of the placenta is derived from placental degeneration at the caudal part of the placenta, and sFlt-1 plays a role in this placental degeneration. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Determination of soluble protein contents from RVNRL

    International Nuclear Information System (INIS)

    Wan Manshol Wan Zin; Nurulhuda Othman

    1996-01-01

    This project was carried out to determine the soluble protein contents on RVNRL film vulcanisates, with respect to the RVNRL storage time, gamma irradiation dose absorbed by the latex and the effect of different leaching time and leaching conditions. These three factors are important in the hope to determine the best possible mean of minimizing the soluble protein contents in products made from RVNRL. Within the nine months storage period employed in the study, the results show that, the longer the storage period the less the soluble protein extracted from the film samples. Gamma irradiation dose absorbed by the samples, between 5.3 kGy to 25.2 kGy seems to influence the soluble protein contents of the RVNRL films vulcanisates. The higher the dose the more was the soluble protein extracted from the film samples. At an absorbed dose of 5.3 kGy and 25.2 kGy, the soluble contents were 0. 198 mg/ml and 0.247 mg/ml respectively. At a fixed leaching temperature, the soluble proteins increases with leaching time and at a fixed leaching time, the soluble proteins increases with leaching temperature. ne highest extractable protein contents was determined at a leaching time of 10 minutes and leaching temperature of 90'C The protein analysis were done by using Modified Lowry Method

  11. Solubility Study of Curatives in Various Rubbers

    NARCIS (Netherlands)

    Guo, R.; Talma, Auke; Datta, Rabin; Dierkes, Wilma K.; Noordermeer, Jacobus W.M.

    2008-01-01

    The previous works on solubility of curatives in rubbers were mainly carried out in natural rubber. Not too much information available on dissimilar rubbers and this is important because most of the compounds today are blends of dissimilar rubbers. Although solubility can be expected to certain

  12. Hansen Solubility Parameters for Octahedral Oligomeric Silsesquioxanes

    Science.gov (United States)

    2012-08-28

    1997, 80, 386-&. 5. Hansen, C. M. The three-dimensional solubility parameter -- key to paint component affinities I. J. Paint Technol. 1967, 39, 104...Chai, J.; Zhang, Q. X.; Han, D. X.; Niu, L. Synthesis and Application of Widely Soluble Graphene Sheets. Langmuir 2010, 26, 12314-12320. 12. Hansen, C

  13. A Colorful Solubility Exercise for Organic Chemistry

    Science.gov (United States)

    Shugrue, Christopher R.; Mentzen, Hans H., II; Linton, Brian R.

    2015-01-01

    A discovery chemistry laboratory has been developed for the introductory organic chemistry student to investigate the concepts of polarity, miscibility, solubility, and density. The simple procedure takes advantage of the solubility of two colored dyes in a series of solvents or solvent mixtures, and the diffusion of colors can be easily…

  14. Solubility of ferrocyanide compounds. Ferrocyanide Safety Project, Interim report FY1994

    International Nuclear Information System (INIS)

    Rai, D.; Felmy, A.R.; Smith, S.C.; Ryan, J.L.

    1994-10-01

    The solubility of Cs 2 NiFe(CN) 6 (c) [1] as a function of NaOH and temperature was determined to ascertain whether [1] shows retrograde solubility (i.e., decreasing solubility with increasing temperature), which would have bearing on the possible formation of ''hot spots'' in the tanks and thus the safety of the ferrocyanide tanks. The results show that the aqueous concentrations of Cs in equilibrium with [1] at 25, 60, 75 and 90 C are similar (within the limits of experimental error), indicating that [1] does not show retrograde solubility. To understand general solubility relationships of Ni 2 Fe(CN) 6 (c) [2] and to determine the influence on solubility of high electrolyte concentrations (e.g., NaNO 3 ) that are commonly encountered in the ferrocyanide tanks, the solubility of [2] as a function of CsNO 3 , NiCl 2 , and NaNO 3 was determined. In general, [2] is fairly insoluble and shows slightly increased solubility at high electrolyte concentrations only. For [2] in NiCl 2 , the aqueous Fe concentrations show first a decrease and then an increase with the increase in NiCl 2 concentrations. The increase in Fe concentrations at high Ni concentrations appears to be the result of replacement of Fe by Ni in the [2] structure. For [2] in CsNO 3 and at 0.001 M Na 4 Fe(CN) 6 , the Cs is quantitatively removed from solution at low added Cs concentrations and appears to approach the final solid composition of [1]. The solubility of [2] in NaNO 3 and at 0.001 M Na 4 Fe(CN) 6 shows an increase in Ni concentrations to about 0.5 mg/l at NaNO 3 concentrations > 1.0 M. These increased Ni concentrations may be the result of substitution of Na for Ni in the solid phase

  15. Analysis of information security reliability: A tutorial

    International Nuclear Information System (INIS)

    Kondakci, Suleyman

    2015-01-01

    This article presents a concise reliability analysis of network security abstracted from stochastic modeling, reliability, and queuing theories. Network security analysis is composed of threats, their impacts, and recovery of the failed systems. A unique framework with a collection of the key reliability models is presented here to guide the determination of the system reliability based on the strength of malicious acts and performance of the recovery processes. A unique model, called Attack-obstacle model, is also proposed here for analyzing systems with immunity growth features. Most computer science curricula do not contain courses in reliability modeling applicable to different areas of computer engineering. Hence, the topic of reliability analysis is often too diffuse to most computer engineers and researchers dealing with network security. This work is thus aimed at shedding some light on this issue, which can be useful in identifying models, their assumptions and practical parameters for estimating the reliability of threatened systems and for assessing the performance of recovery facilities. It can also be useful for the classification of processes and states regarding the reliability of information systems. Systems with stochastic behaviors undergoing queue operations and random state transitions can also benefit from the approaches presented here. - Highlights: • A concise survey and tutorial in model-based reliability analysis applicable to information security. • A framework of key modeling approaches for assessing reliability of networked systems. • The framework facilitates quantitative risk assessment tasks guided by stochastic modeling and queuing theory. • Evaluation of approaches and models for modeling threats, failures, impacts, and recovery analysis of information systems

  16. Hawaii Electric System Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Loose, Verne William [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Silva Monroy, Cesar Augusto [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2012-08-01

    This report addresses Hawaii electric system reliability issues; greater emphasis is placed on short-term reliability but resource adequacy is reviewed in reference to electric consumers’ views of reliability “worth” and the reserve capacity required to deliver that value. The report begins with a description of the Hawaii electric system to the extent permitted by publicly available data. Electrical engineering literature in the area of electric reliability is researched and briefly reviewed. North American Electric Reliability Corporation standards and measures for generation and transmission are reviewed and identified as to their appropriateness for various portions of the electric grid and for application in Hawaii. Analysis of frequency data supplied by the State of Hawaii Public Utilities Commission is presented together with comparison and contrast of performance of each of the systems for two years, 2010 and 2011. Literature tracing the development of reliability economics is reviewed and referenced. A method is explained for integrating system cost with outage cost to determine the optimal resource adequacy given customers’ views of the value contributed by reliable electric supply. The report concludes with findings and recommendations for reliability in the State of Hawaii.

  17. Hawaii electric system reliability.

    Energy Technology Data Exchange (ETDEWEB)

    Silva Monroy, Cesar Augusto; Loose, Verne William

    2012-09-01

    This report addresses Hawaii electric system reliability issues; greater emphasis is placed on short-term reliability but resource adequacy is reviewed in reference to electric consumers' views of reliability %E2%80%9Cworth%E2%80%9D and the reserve capacity required to deliver that value. The report begins with a description of the Hawaii electric system to the extent permitted by publicly available data. Electrical engineering literature in the area of electric reliability is researched and briefly reviewed. North American Electric Reliability Corporation standards and measures for generation and transmission are reviewed and identified as to their appropriateness for various portions of the electric grid and for application in Hawaii. Analysis of frequency data supplied by the State of Hawaii Public Utilities Commission is presented together with comparison and contrast of performance of each of the systems for two years, 2010 and 2011. Literature tracing the development of reliability economics is reviewed and referenced. A method is explained for integrating system cost with outage cost to determine the optimal resource adequacy given customers' views of the value contributed by reliable electric supply. The report concludes with findings and recommendations for reliability in the State of Hawaii.

  18. Improving machinery reliability

    CERN Document Server

    Bloch, Heinz P

    1998-01-01

    This totally revised, updated and expanded edition provides proven techniques and procedures that extend machinery life, reduce maintenance costs, and achieve optimum machinery reliability. This essential text clearly describes the reliability improvement and failure avoidance steps practiced by best-of-class process plants in the U.S. and Europe.

  19. LED system reliability

    NARCIS (Netherlands)

    Driel, W.D. van; Yuan, C.A.; Koh, S.; Zhang, G.Q.

    2011-01-01

    This paper presents our effort to predict the system reliability of Solid State Lighting (SSL) applications. A SSL system is composed of a LED engine with micro-electronic driver(s) that supplies power to the optic design. Knowledge of system level reliability is not only a challenging scientific

  20. Reliability of neural encoding

    DEFF Research Database (Denmark)

    Alstrøm, Preben; Beierholm, Ulrik; Nielsen, Carsten Dahl

    2002-01-01

    The reliability with which a neuron is able to create the same firing pattern when presented with the same stimulus is of critical importance to the understanding of neuronal information processing. We show that reliability is closely related to the process of phaselocking. Experimental results f...

  1. Design reliability engineering

    International Nuclear Information System (INIS)

    Buden, D.; Hunt, R.N.M.

    1989-01-01

    Improved design techniques are needed to achieve high reliability at minimum cost. This is especially true of space systems where lifetimes of many years without maintenance are needed and severe mass limitations exist. Reliability must be designed into these systems from the start. Techniques are now being explored to structure a formal design process that will be more complete and less expensive. The intent is to integrate the best features of design, reliability analysis, and expert systems to design highly reliable systems to meet stressing needs. Taken into account are the large uncertainties that exist in materials, design models, and fabrication techniques. Expert systems are a convenient method to integrate into the design process a complete definition of all elements that should be considered and an opportunity to integrate the design process with reliability, safety, test engineering, maintenance and operator training. 1 fig

  2. Bayesian methods in reliability

    Science.gov (United States)

    Sander, P.; Badoux, R.

    1991-11-01

    The present proceedings from a course on Bayesian methods in reliability encompasses Bayesian statistical methods and their computational implementation, models for analyzing censored data from nonrepairable systems, the traits of repairable systems and growth models, the use of expert judgment, and a review of the problem of forecasting software reliability. Specific issues addressed include the use of Bayesian methods to estimate the leak rate of a gas pipeline, approximate analyses under great prior uncertainty, reliability estimation techniques, and a nonhomogeneous Poisson process. Also addressed are the calibration sets and seed variables of expert judgment systems for risk assessment, experimental illustrations of the use of expert judgment for reliability testing, and analyses of the predictive quality of software-reliability growth models such as the Weibull order statistics.

  3. Indomethacin solubility estimation in 1,4-dioxane + water mixtures by the extended hildebrand solubility approach

    Directory of Open Access Journals (Sweden)

    Miller A Ruidiaz

    2011-09-01

    Full Text Available Extended Hildebrand Solubility Approach (EHSA was successfully applied to evaluate the solubility of Indomethacin in 1,4-dioxane + water mixtures at 298.15 K. An acceptable correlation-performance of EHSA was found by using a regular polynomial model in order four of the W interaction parameter vs. solubility parameter of the mixtures (overall deviation was 8.9%. Although the mean deviation obtained was similar to that obtained directly by means of an empiric regression of the experimental solubility vs. mixtures solubility parameters, the advantages of EHSA are evident because it requires physicochemical properties easily available for drugs.

  4. Reliability evaluation programmable logic devices

    International Nuclear Information System (INIS)

    Srivani, L.; Murali, N.; Thirugnana Murthy, D.; Satya Murty, S.A.V.

    2014-01-01

    Programmable Logic Devices (PLD) are widely used as basic building modules in high integrity systems, considering their robust features such as gate density, performance, speed etc. PLDs are used to implement digital design such as bus interface logic, control logic, sequencing logic, glue logic etc. Due to semiconductor evolution, new PLDs with state-of-the-art features are arriving to the market. Since these devices are reliable as per the manufacturer's specification, they were used in the design of safety systems. But due to their reduced market life, the availability of performance data is limited. So evaluating the PLD before deploying in a safety system is very important. This paper presents a survey on the use of PLDs in the nuclear domain and the steps involved in the evaluation of PLD using Quantitative Accelerated Life Testing. (author)

  5. Temperature Dependence of Mineral Solubility in Water. Part 2. Alkaline and Alkaline Earth Bromides

    Science.gov (United States)

    Krumgalz, B. S.

    2018-03-01

    Databases of alkaline and alkaline earth bromide solubilities in water at various temperatures were created using experimental data from publications over about the last two centuries. Statistical critical evaluation of the created databases was produced since there were enough independent data sources to justify such evaluation. The reliable experimental data were adequately described by polynomial expressions over various temperature ranges. Using the Pitzer approach for ionic activity and osmotic coefficients, the thermodynamic solubility products for the discussed bromide minerals have been calculated at various temperature intervals and also represented by polynomial expressions.

  6. Spectroscopy, modeling and computation of metal chelate solubility in supercritical CO2. 1998 annual progress report

    International Nuclear Information System (INIS)

    Brennecke, J.F.; Chateauneuf, J.E.; Stadtherr, M.A.

    1998-01-01

    'This report summarizes work after 1 year and 8 months (9/15/96-5/14/98) of a 3 year project. Thus far, progress has been made in: (1) the measurement of the solubility of metal chelates in SC CO 2 with and without added cosolvents, (2) the spectroscopic determination of preferential solvation of metal chelates by cosolvents in SC CO 2 solutions, and (3) the development of a totally reliable computational technique for phase equilibrium computations. An important factor in the removal of metals from solid matrices with CO 2 /chelate mixtures is the equilibrium solubility of the metal chelate complex in the CO 2 .'

  7. Review of progress in quantitative nondestructive evaluation

    International Nuclear Information System (INIS)

    Thompson, D.O.; Chimenti, D.E.

    1983-01-01

    A comprehensive review of the current state of quantitative nondestructive evaluation (NDE), this volume brings together papers by researchers working in government, private industry, and university laboratories. Their papers cover a wide range of interests and concerns for researchers involved in theoretical and applied aspects of quantitative NDE. Specific topics examined include reliability probability of detection--ultrasonics and eddy currents weldments closure effects in fatigue cracks technology transfer ultrasonic scattering theory acoustic emission ultrasonic scattering, reliability and penetrating radiation metal matrix composites ultrasonic scattering from near-surface flaws ultrasonic multiple scattering

  8. Serum Soluble Corin is Decreased in Stroke.

    Science.gov (United States)

    Peng, Hao; Zhu, Fangfang; Shi, Jijun; Han, Xiujie; Zhou, Dan; Liu, Yan; Zhi, Zhongwen; Zhang, Fuding; Shen, Yun; Ma, Juanjuan; Song, Yulin; Hu, Weidong

    2015-07-01

    Soluble corin was decreased in coronary heart disease. Given the connections between cardiac dysfunction and stroke, circulating corin might be a candidate marker of stroke risk. However, the association between circulating corin and stroke has not yet been studied in humans. Here, we aimed to examine the association in patients wtith stroke and community-based healthy controls. Four hundred eighty-one patients with ischemic stroke, 116 patients with hemorrhagic stroke, and 2498 healthy controls were studied. Serum soluble corin and some conventional risk factors of stroke were examined. Because circulating corin was reported to be varied between men and women, the association between serum soluble corin and stroke was evaluated in men and women, respectively. Patients with ischemic and hemorrhagic stroke had a significantly lower level of serum soluble corin than healthy controls in men and women (all P values, stroke than men in the highest quartile. Women in the lowest quartile of serum soluble corin were also more likely to have ischemic (OR, 3.10; 95% confidence interval, 1.76-5.44) and hemorrhagic (OR, 8.54; 95% confidence interval, 2.35-31.02) stroke than women in the highest quartile. ORs of ischemic and hemorrhagic stroke were significantly increased with the decreasing levels of serum soluble corin in men and women (all P values for trend, stroke compared with healthy controls. Our findings raise the possibility that serum soluble corin may have a pathogenic role in stroke. © 2015 American Heart Association, Inc.

  9. Reliability of construction materials

    International Nuclear Information System (INIS)

    Merz, H.

    1976-01-01

    One can also speak of reliability with respect to materials. While for reliability of components the MTBF (mean time between failures) is regarded as the main criterium, this is replaced with regard to materials by possible failure mechanisms like physical/chemical reaction mechanisms, disturbances of physical or chemical equilibrium, or other interactions or changes of system. The main tasks of the reliability analysis of materials therefore is the prediction of the various failure reasons, the identification of interactions, and the development of nondestructive testing methods. (RW) [de

  10. Reliability and mechanical design

    International Nuclear Information System (INIS)

    Lemaire, Maurice

    1997-01-01

    A lot of results in mechanical design are obtained from a modelisation of physical reality and from a numerical solution which would lead to the evaluation of needs and resources. The goal of the reliability analysis is to evaluate the confidence which it is possible to grant to the chosen design through the calculation of a probability of failure linked to the retained scenario. Two types of analysis are proposed: the sensitivity analysis and the reliability analysis. Approximate methods are applicable to problems related to reliability, availability, maintainability and safety (RAMS)

  11. RTE - 2013 Reliability Report

    International Nuclear Information System (INIS)

    Denis, Anne-Marie

    2014-01-01

    RTE publishes a yearly reliability report based on a standard model to facilitate comparisons and highlight long-term trends. The 2013 report is not only stating the facts of the Significant System Events (ESS), but it moreover underlines the main elements dealing with the reliability of the electrical power system. It highlights the various elements which contribute to present and future reliability and provides an overview of the interaction between the various stakeholders of the Electrical Power System on the scale of the European Interconnected Network. (author)

  12. Solubilities of uranium for TILA-99

    International Nuclear Information System (INIS)

    Ollila, K.; Ahonen, L.

    1998-11-01

    This report presents the evaluation of the uranium solubilities in the reference waters of TILA-99. The behaviour of uranium has been discussed separately in the near-field and far-field conditions. The bentonite/groundwater interactions have been considered in the compositions of the fresh and saline near-field reference waters. The far-field groundwaters' compositions include fresh, brackish, saline and very saline, almost brine-type compositions. The pH and redox conditions, as the main parameters affecting the solubilities, are considered. A literature study was made in order to obtain information on the recent dissolution and leaching experiments of UO 2 and spent fuel. The latest literature includes studies on UO 2 solubility under anoxic conditions, in which the methods for simulating the reducing conditions of deep groundwater have been improved. Studies on natural uraninite and its alteration products give a valuable insight into the long-term behaviour of spent fuel. Also the solubility equilibria for some relevant poorly known uranium minerals have been determined. The solubilities of the selected solubility-limiting phases were calculated using the geochemical code, EQ3/6. The NEA database for uranium was the basis for the modelling. The recently extended and updated SR '97 database was used for comparison. The solubility products for uranophane were taken from the latest literature. The recommended values for solubilities were given after a comparison between the calculated solubilities, experimental information and measured concentrations in natural groundwaters. The experiments include several UO 2 dissolution studies in synthetic groundwaters with compositions close to the reference groundwaters. (author)

  13. Solubilities of uranium for TILA-99

    Energy Technology Data Exchange (ETDEWEB)

    Ollila, K. [VTT Chemical Technology, Espoo (Finland); Ahonen, L. [Geological Survey of Finland, Espoo (Finland)

    1998-11-01

    This report presents the evaluation of the uranium solubilities in the reference waters of TILA-99. The behaviour of uranium has been discussed separately in the near-field and far-field conditions. The bentonite/groundwater interactions have been considered in the compositions of the fresh and saline near-field reference waters. The far-field groundwaters` compositions include fresh, brackish, saline and very saline, almost brine-type compositions. The pH and redox conditions, as the main parameters affecting the solubilities, are considered. A literature study was made in order to obtain information on the recent dissolution and leaching experiments of UO{sub 2} and spent fuel. The latest literature includes studies on UO{sub 2} solubility under anoxic conditions, in which the methods for simulating the reducing conditions of deep groundwater have been improved. Studies on natural uraninite and its alteration products give a valuable insight into the long-term behaviour of spent fuel. Also the solubility equilibria for some relevant poorly known uranium minerals have been determined. The solubilities of the selected solubility-limiting phases were calculated using the geochemical code, EQ3/6. The NEA database for uranium was the basis for the modelling. The recently extended and updated SR `97 database was used for comparison. The solubility products for uranophane were taken from the latest literature. The recommended values for solubilities were given after a comparison between the calculated solubilities, experimental information and measured concentrations in natural groundwaters. The experiments include several UO{sub 2} dissolution studies in synthetic groundwaters with compositions close to the reference groundwaters. (author) 81 refs.

  14. Quantitative approaches in climate change ecology

    DEFF Research Database (Denmark)

    Brown, Christopher J.; Schoeman, David S.; Sydeman, William J.

    2011-01-01

    Contemporary impacts of anthropogenic climate change on ecosystems are increasingly being recognized. Documenting the extent of these impacts requires quantitative tools for analyses of ecological observations to distinguish climate impacts in noisy data and to understand interactions between...... climate variability and other drivers of change. To assist the development of reliable statistical approaches, we review the marine climate change literature and provide suggestions for quantitative approaches in climate change ecology. We compiled 267 peer‐reviewed articles that examined relationships...

  15. Development of quantitative x-ray microtomography

    International Nuclear Information System (INIS)

    Deckman, H.W.; Dunsmuir, J.A.; D'Amico, K.L.; Ferguson, S.R.; Flannery, B.P.

    1990-01-01

    The authors have developed several x-ray microtomography systems which function as quantitative three dimensional x-ray microscopes. In this paper the authors describe the evolutionary path followed from making the first high resolution experimental microscopes to later generations which can be routinely used for investigating materials. Developing the instrumentation for reliable quantitative x-ray microscopy using synchrotron and laboratory based x-ray sources has led to other imaging modalities for obtaining temporal and spatial two dimensional information

  16. Relationship between Molecular Structure Characteristics of Feed Proteins and Protein In vitro Digestibility and Solubility.

    Science.gov (United States)

    Bai, Mingmei; Qin, Guixin; Sun, Zewei; Long, Guohui

    2016-08-01

    The nutritional value of feed proteins and their utilization by livestock are related not only to the chemical composition but also to the structure of feed proteins, but few studies thus far have investigated the relationship between the structure of feed proteins and their solubility as well as digestibility in monogastric animals. To address this question we analyzed soybean meal, fish meal, corn distiller's dried grains with solubles, corn gluten meal, and feather meal by Fourier transform infrared (FTIR) spectroscopy to determine the protein molecular spectral band characteristics for amides I and II as well as α-helices and β-sheets and their ratios. Protein solubility and in vitro digestibility were measured with the Kjeldahl method using 0.2% KOH solution and the pepsin-pancreatin two-step enzymatic method, respectively. We found that all measured spectral band intensities (height and area) of feed proteins were correlated with their the in vitro digestibility and solubility (p≤0.003); moreover, the relatively quantitative amounts of α-helices, random coils, and α-helix to β-sheet ratio in protein secondary structures were positively correlated with protein in vitro digestibility and solubility (p≤0.004). On the other hand, the percentage of β-sheet structures was negatively correlated with protein in vitro digestibility (pdigestibility at 28 h and solubility. Furthermore, the α-helix-to-β-sheet ratio can be used to predict the nutritional value of feed proteins.

  17. Solubilities of gases in ionic liquids using a corresponding-states approach to Kirkwood-Buff solution theory

    DEFF Research Database (Denmark)

    Ellegaard, Martin Dela; Abildskov, Jens; O’Connell, John P.

    2011-01-01

    The solubilities of gases in ionic liquids and compressed liquid densities have been successfully described over a wide range of conditions using a reformulated corresponding-states formulation for direct correlation function integrals. In addition, comparisons with experimental data show reliabl...... prediction of ionic liquid characteristic properties from simple rules.......The solubilities of gases in ionic liquids and compressed liquid densities have been successfully described over a wide range of conditions using a reformulated corresponding-states formulation for direct correlation function integrals. In addition, comparisons with experimental data show reliable...

  18. Solubility limited radionuclide transport through geologic media

    International Nuclear Information System (INIS)

    Muraoka, Susumu; Iwamoto, Fumio; Pigford, T.H.

    1980-11-01

    Prior analyses for the migration of radionuclides neglect solubility limits of resolved radionuclide in geologic media. But actually some of the actinides may appear in chemical forms of very low solubility. In the present report we have proposed the migration model with no decay parents in which concentration of radionuclide is limited in concentration of solubility in ground water. In addition, the analytical solutions of the space-time-dependent concentration are presented in the case of step release, band release and exponential release. (author)

  19. Residual nilpotence and residual solubility of groups

    International Nuclear Information System (INIS)

    Mikhailov, R V

    2005-01-01

    The properties of the residual nilpotence and the residual solubility of groups are studied. The main objects under investigation are the class of residually nilpotent groups such that each central extension of these groups is also residually nilpotent and the class of residually soluble groups such that each Abelian extension of these groups is residually soluble. Various examples of groups not belonging to these classes are constructed by homological methods and methods of the theory of modules over group rings. Several applications of the theory under consideration are presented and problems concerning the residual nilpotence of one-relator groups are considered.

  20. Water Soluble Polymers for Pharmaceutical Applications

    Directory of Open Access Journals (Sweden)

    Veeran Gowda Kadajji

    2011-11-01

    Full Text Available Advances in polymer science have led to the development of novel drug delivery systems. Some polymers are obtained from natural resources and then chemically modified for various applications, while others are chemically synthesized and used. A large number of natural and synthetic polymers are available. In the present paper, only water soluble polymers are described. They have been explained in two categories (1 synthetic and (2 natural. Drug polymer conjugates, block copolymers, hydrogels and other water soluble drug polymer complexes have also been explained. The general properties and applications of different water soluble polymers in the formulation of different dosage forms, novel delivery systems and biomedical applications will be discussed.

  1. Molecular Thermodynamic Modeling of Mixed Solvent Solubility

    DEFF Research Database (Denmark)

    Ellegaard, Martin Dela; Abildskov, Jens; O’Connell, John P.

    2010-01-01

    A method based on statistical mechanical fluctuation solution theory for composition derivatives of activity coefficients is employed for estimating dilute solubilities of 11 solid pharmaceutical solutes in nearly 70 mixed aqueous and nonaqueous solvent systems. The solvent mixtures range from...... nearly ideal to strongly nonideal. The database covers a temperature range from 293 to 323 K. Comparisons with available data and other existing solubility methods show that the method successfully describes a variety of observed mixed solvent solubility behaviors using solute−solvent parameters from...

  2. Smart polyelectrolyte microcapsules as carriers for water-soluble small molecular drug.

    Science.gov (United States)

    Song, Weixing; He, Qiang; Möhwald, Helmuth; Yang, Yang; Li, Junbai

    2009-10-15

    Heat treatment is introduced as a simple method for the encapsulation of low molecular weight water-soluble drugs within layer-by-layer assembled microcapsules. A water-soluble drug, procainamide hydrochloride, could thus be encapsulated in large amount and enriched by more than 2 orders of magnitude in the assembled PDADMAC/PSS capsules. The shrunk capsules could control the unloading rate of drugs, and the drugs could be easily unloaded using ultrasonic treatment. The encapsulated amount could be quantitatively controlled via the drug concentration in the bulk. We also found that smaller capsules possess higher encapsulation capability.

  3. Approach to reliability assessment

    International Nuclear Information System (INIS)

    Green, A.E.; Bourne, A.J.

    1975-01-01

    Experience has shown that reliability assessments can play an important role in the early design and subsequent operation of technological systems where reliability is at a premium. The approaches to and techniques for such assessments, which have been outlined in the paper, have been successfully applied in variety of applications ranging from individual equipments to large and complex systems. The general approach involves the logical and systematic establishment of the purpose, performance requirements and reliability criteria of systems. This is followed by an appraisal of likely system achievment based on the understanding of different types of variational behavior. A fundamental reliability model emerges from the correlation between the appropriate Q and H functions for performance requirement and achievement. This model may cover the complete spectrum of performance behavior in all the system dimensions

  4. Reliability assessment using the concept of possibility

    International Nuclear Information System (INIS)

    Ping, R.; Zhao, G.

    1994-01-01

    The role of the possibility theory in the quantitative approach to the reliability of large scale systems, in particular man-machine systems, is discussed. According to the original idea due to professor L.A. Zadeh, an error rate may be associated with a possibility distribution and a probability distribution. They describe the potentiallity and the actuality for error. This is especially important for the analysis of big accidents

  5. The rating reliability calculator

    Directory of Open Access Journals (Sweden)

    Solomon David J

    2004-04-01

    Full Text Available Abstract Background Rating scales form an important means of gathering evaluation data. Since important decisions are often based on these evaluations, determining the reliability of rating data can be critical. Most commonly used methods of estimating reliability require a complete set of ratings i.e. every subject being rated must be rated by each judge. Over fifty years ago Ebel described an algorithm for estimating the reliability of ratings based on incomplete data. While his article has been widely cited over the years, software based on the algorithm is not readily available. This paper describes an easy-to-use Web-based utility for estimating the reliability of ratings based on incomplete data using Ebel's algorithm. Methods The program is available public use on our server and the source code is freely available under GNU General Public License. The utility is written in PHP, a common open source imbedded scripting language. The rating data can be entered in a convenient format on the user's personal computer that the program will upload to the server for calculating the reliability and other statistics describing the ratings. Results When the program is run it displays the reliability, number of subject rated, harmonic mean number of judges rating each subject, the mean and standard deviation of the averaged ratings per subject. The program also displays the mean, standard deviation and number of ratings for each subject rated. Additionally the program will estimate the reliability of an average of a number of ratings for each subject via the Spearman-Brown prophecy formula. Conclusion This simple web-based program provides a convenient means of estimating the reliability of rating data without the need to conduct special studies in order to provide complete rating data. I would welcome other researchers revising and enhancing the program.

  6. Structural systems reliability analysis

    International Nuclear Information System (INIS)

    Frangopol, D.

    1975-01-01

    For an exact evaluation of the reliability of a structure it appears necessary to determine the distribution densities of the loads and resistances and to calculate the correlation coefficients between loads and between resistances. These statistical characteristics can be obtained only on the basis of a long activity period. In case that such studies are missing the statistical properties formulated here give upper and lower bounds of the reliability. (orig./HP) [de

  7. Reliability and maintainability

    International Nuclear Information System (INIS)

    1994-01-01

    Several communications in this conference are concerned with nuclear plant reliability and maintainability; their titles are: maintenance optimization of stand-by Diesels of 900 MW nuclear power plants; CLAIRE: an event-based simulation tool for software testing; reliability as one important issue within the periodic safety review of nuclear power plants; design of nuclear building ventilation by the means of functional analysis; operation characteristic analysis for a power industry plant park, as a function of influence parameters

  8. Reliability data book

    International Nuclear Information System (INIS)

    Bento, J.P.; Boerje, S.; Ericsson, G.; Hasler, A.; Lyden, C.O.; Wallin, L.; Poern, K.; Aakerlund, O.

    1985-01-01

    The main objective for the report is to improve failure data for reliability calculations as parts of safety analyses for Swedish nuclear power plants. The work is based primarily on evaluations of failure reports as well as information provided by the operation and maintenance staff of each plant. In the report are presented charts of reliability data for: pumps, valves, control rods/rod drives, electrical components, and instruments. (L.E.)

  9. Multidisciplinary System Reliability Analysis

    Science.gov (United States)

    Mahadevan, Sankaran; Han, Song; Chamis, Christos C. (Technical Monitor)

    2001-01-01

    The objective of this study is to develop a new methodology for estimating the reliability of engineering systems that encompass multiple disciplines. The methodology is formulated in the context of the NESSUS probabilistic structural analysis code, developed under the leadership of NASA Glenn Research Center. The NESSUS code has been successfully applied to the reliability estimation of a variety of structural engineering systems. This study examines whether the features of NESSUS could be used to investigate the reliability of systems in other disciplines such as heat transfer, fluid mechanics, electrical circuits etc., without considerable programming effort specific to each discipline. In this study, the mechanical equivalence between system behavior models in different disciplines are investigated to achieve this objective. A new methodology is presented for the analysis of heat transfer, fluid flow, and electrical circuit problems using the structural analysis routines within NESSUS, by utilizing the equivalence between the computational quantities in different disciplines. This technique is integrated with the fast probability integration and system reliability techniques within the NESSUS code, to successfully compute the system reliability of multidisciplinary systems. Traditional as well as progressive failure analysis methods for system reliability estimation are demonstrated, through a numerical example of a heat exchanger system involving failure modes in structural, heat transfer and fluid flow disciplines.

  10. A methodology to incorporate organizational factors into human reliability analysis

    International Nuclear Information System (INIS)

    Li Pengcheng; Chen Guohua; Zhang Li; Xiao Dongsheng

    2010-01-01

    A new holistic methodology for Human Reliability Analysis (HRA) is proposed to model the effects of the organizational factors on the human reliability. Firstly, a conceptual framework is built, which is used to analyze the causal relationships between the organizational factors and human reliability. Then, the inference model for Human Reliability Analysis is built by combining the conceptual framework with Bayesian networks, which is used to execute the causal inference and diagnostic inference of human reliability. Finally, a case example is presented to demonstrate the specific application of the proposed methodology. The results show that the proposed methodology of combining the conceptual model with Bayesian Networks can not only easily model the causal relationship between organizational factors and human reliability, but in a given context, people can quantitatively measure the human operational reliability, and identify the most likely root causes or the prioritization of root causes caused human error. (authors)

  11. Analysis and Application of Reliability

    International Nuclear Information System (INIS)

    Jeong, Hae Seong; Park, Dong Ho; Kim, Jae Ju

    1999-05-01

    This book tells of analysis and application of reliability, which includes definition, importance and historical background of reliability, function of reliability and failure rate, life distribution and assumption of reliability, reliability of unrepaired system, reliability of repairable system, sampling test of reliability, failure analysis like failure analysis by FEMA and FTA, and cases, accelerated life testing such as basic conception, acceleration and acceleration factor, and analysis of accelerated life testing data, maintenance policy about alternation and inspection.

  12. Solubility of carbohydrates in heavy water.

    Science.gov (United States)

    Cardoso, Marcus V C; Carvalho, Larissa V C; Sabadini, Edvaldo

    2012-05-15

    The solubility of several mono-(glucose and xylose), di-(sucrose and maltose), tri-(raffinose) and cyclic (α-cyclodextrin) saccharides in H(2)O and in D(2)O were measured over a range of temperatures. The solution enthalpies for the different carbohydrates in the two solvents were determined using the vant' Hoff equation and the values in D(2)O are presented here for the first time. Our findings indicate that the replacement of H(2)O by D(2)O remarkably decreases the solubilities of the less soluble carbohydrates, such as maltose, raffinose and α-cyclodextrin. On the other hand, the more soluble saccharides, glucose, xylose, and sucrose, are practically insensitive to the H/D replacement in water. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Enhancement of Solubility and Bioavailability of Candesartan ...

    African Journals Online (AJOL)

    Purpose: To enhance the otherwise poor solubility and bioavailability of candesartan cilexetil (CDS). Methods: This ... PEG 6000-based solid dispersions showed 1st order drug release kinetics. ..... the liver due to quercetin's inhibitory effect on.

  14. An Introduction to the Understanding of Solubility.

    Science.gov (United States)

    Letcher, Trevor M.; Battino, Rubin

    2001-01-01

    Explores different solubility processes and related issues, including the second law of thermodynamics and ideal mixtures, real liquids, intermolecular forces, and solids in liquids or gases in liquids. (Contains 22 references.) (ASK)

  15. Progress in the research of neptunium solubility

    International Nuclear Information System (INIS)

    Jiang Tao; Liu Yongye; Yao Jun

    2012-01-01

    237 Np is considered a possible long-term potential threat for environment, because of its long half-life, high toxicity and its mobile nature under aerobic conditions due to the high chemical stability of its pentavalent state. Therefore 237 Np is considered as one of high-level radioactive waste and need to be disposed in deep geologic disposal repository. The dissolution behavior is an important aspect of migration research. The solubility is considered very important for high level waste geological disposal safety and environmental evaluation. The solubility determines the maximum concentration of the discharge, and then it is initial concentration of the radionuclides migration to the environment. The solubility impact directly on radionuclides migration in host rock, and can be used to predict the concentration and speciation of radionuclides in groundwater around disposal sites many years later. This paper focused on research results of the solubility, some proposals for Np dissolution chemistry research were also been suggested. (authors)

  16. Application of mixture experimental design to simvastatin apparent solubility predictions in the microemulsifion formed by self-microemulsifying.

    Science.gov (United States)

    Meng, Jian; Zheng, Liangyuan

    2007-09-01

    Self-microemulsifying drug delivery systems (SMEDDS) are useful to improve the bioavailability of poorly water-soluble drugs by increasing their apparent solubility through solubilization. However, very few studies, to date, have systematically examined the level of drug apparent solubility in o/w microemulsion formed by self-microemulsifying. In this study, a mixture experimental design was used to simulate the influence of the compositions on simvastatin apparent solubility quantitatively through an empirical model. The reduced cubic polynomial equation successfully modeled the evolution of simvastatin apparent solubility. The results were presented using an analysis of response surface showing a scale of possible simvastatin apparent solubility between 0.0024 ~ 29.0 mg/mL. Moreover, this technique showed that simvastatin apparent solubility was mainly influenced by microemulsion concentration and, suggested that the drug would precipitate in the gastrointestinal tract due to dilution by gastrointestinal fluids. Furthermore, the model would help us design the formulation to maximize the drug apparent solubility and avoid precipitation of the drug.

  17. Hydrogen solubility in polycrystalline - and nonocrystalline niobium

    International Nuclear Information System (INIS)

    Ishikawa, T.T.; Silva, J.R.G. da

    1981-01-01

    Hydrogen solubility in polycrystalline and monocrystalline niobium was measured in the range 400 0 C to 1000 0 C at one atmosphere hydrogen partial pressure. The experimental technique consists of saturation of the solvent metal with hydrogen, followed by quenching and analysis of the solid solution. It is presented solubility curves versus reciprocal of the absolute doping temperature, associated with their thermodynamical equation. (Author) [pt

  18. Respiratory carcinogenicity assessment of soluble nickel compounds.

    OpenAIRE

    Oller, Adriana R

    2002-01-01

    The many chemical forms of nickel differ in physicochemical properties and biological effects. Health assessments for each main category of nickel species are needed. The carcinogenicity assessment of water-soluble nickel compounds has proven particularly difficult. Epidemiologic evidence indicates an association between inhalation exposures to nickel refinery dust containing soluble nickel compounds and increased risk of respiratory cancers. However, the nature of this association is unclear...

  19. Correlation of Helium Solubility in Liquid Nitrogen

    Science.gov (United States)

    VanDresar, Neil T.; Zimmerli, Gregory A.

    2012-01-01

    A correlation has been developed for the equilibrium mole fraction of soluble gaseous helium in liquid nitrogen as a function of temperature and pressure. Experimental solubility data was compiled and provided by National Institute of Standards and Technology (NIST). Data from six sources was used to develop a correlation within the range of 0.5 to 9.9 MPa and 72.0 to 119.6 K. The relative standard deviation of the correlation is 6.9 percent.

  20. Hydrothermal solubility of uraninite. Final technical report

    International Nuclear Information System (INIS)

    Parks, G.A.; Pohl, D.C.

    1985-01-01

    Experimental measurements of the solubility of UO 2 from 100 to 300 0 C under 500 bars H 2 , in NaCl solutions at pH from 1 to 8 do not agree with solubilities calculated using existing thermodynamic databases. For pH 2 (hyd) has precipitated and is controlling solubility. For pH > 8, solubilities at all temperatures are much lower than predicted, suggesting that the U(OH)/sub delta/ - complex is much weaker than predicted. Extrapolated to 25 0 C, high pH solubility agrees within experimental error with the upper limit suggested by Ryan and Rai (1983). In the pH range 2 to 6, solubilities are up to three orders of magnitude lower than predicted for temperatures exceeding 200 0 C and up to two orders higher than predicted at lower temperatures. pH dependence in this region is negligible suggesting that U(OH) 4 (aq) predominates, thus the stability of this species is higher than presently estimated at low temperatures, but the enthalpy of solution is smaller. A low maximum observed near pH approx. =3 is presently unexplained. 40 refs., 16 figs., 12 tabs

  1. Uranium solubility and speciation in ground water

    International Nuclear Information System (INIS)

    Ollila, K.

    1985-04-01

    The purpose of this study has been to assess the solubility and possible species of uranium in groundwater at the disposal conditions of spent fuel. The effects of radiolysis and bentonite are considered. The assessment is based on the theoretical calculations found in the literature. The Finnish experimental results are included. The conservative estimate for uranium solubility under the oxidizing conditions caused by alpha radiolysis is based on the oxidation of uranium to the U(VI) state and formation of carbonate complex. For the groundwater with the typical carbonate content of 275 mg/l and the high carbonate content of 485 mg/l due to bentonite, the solubility values of 360 mg u/l and 950 mg U/l, are obtained, respectively. The experimental results predict considerably lower values, 0.5-20 mg U/l. The solubility of uranium under the undisturbed reducing conditions may be calculated based on the hydrolysis, carbonate complexation and redox reactions. The results vary considerably depending on the thermodynamic data used. The wide ranges of the most important groundwater parameters are seen in the solubility values. The experimental results show the same trends. As a conservative value for the solubility in reducing groundwater 50-500 μg U/l is estimated. (author)

  2. Sibutramine characterization and solubility, a theoretical study

    Science.gov (United States)

    Aceves-Hernández, Juan M.; Nicolás Vázquez, Inés; Hinojosa-Torres, Jaime; Penieres Carrillo, Guillermo; Arroyo Razo, Gabriel; Miranda Ruvalcaba, René

    2013-04-01

    Solubility data from sibutramine (SBA) in a family of alcohols were obtained at different temperatures. Sibutramine was characterized by using thermal analysis and X-ray diffraction technique. Solubility data were obtained by the saturation method. The van't Hoff equation was used to obtain the theoretical solubility values and the ideal solvent activity coefficient. No polymorphic phenomena were found from the X-ray diffraction analysis, even though this compound is a racemic mixture of (+) and (-) enantiomers. Theoretical calculations showed that the polarisable continuum model was able to reproduce the solubility and stability of sibutramine molecule in gas phase, water and a family of alcohols at B3LYP/6-311++G (d,p) level of theory. Dielectric constant, dipolar moment and solubility in water values as physical parameters were used in those theoretical calculations for explaining that behavior. Experimental and theoretical results were compared and good agreement was obtained. Sibutramine solubility increased from methanol to 1-octanol in theoretical and experimental results.

  3. Neutron induced prompt gamma-ray technique for investigation the moisture and soluble salt problem in the historical building

    International Nuclear Information System (INIS)

    Lahasen Norman Shah Dahing; Ismail Mustapha; Jaafar Abdullah; Susan Maria Sipaun

    2006-01-01

    The degradation of some building materials such as brick and mortar is a major problem for the preservation of monuments or historic structures, especially where it is desirable to preserve the original fabric of the building. Such degradation often arises from the presence of contaminants in the constituent materials. In building materials, water is a major course of deterioration, both by acting as a solvent for various building materials components and by exerting stresses on the structure during thermal cycle. The soluble salts, notably chlorides, damage the structure either by periodically dissolving and recrystallising within the pores or by promoting corrosion. Knowledge of the presence and distribution of contaminants is needed for effective treatment and preservation. However, most of techniques have been use to evaluate the deterioration of historic building and structure is generally limited to visual observation and destructive tests of core samples. Some non-destructive testing (NDT) methods like electrical conductivity technique and ultrasonic testing, can identify cracks and voids, but cannot provide any information on the possible causes of these problems. To overcome this limitation, a new method, called n eutron-induced prompt gamma-ray technique (NIPGAT) has being developed at MINT for preservation of monuments and historic buildings. This method is useful for analytical techniques for identification both qualitative and quantitative multi-element analysis of major, minor and trace element of present in the sample. For many elements and applications, this technique offers high sensitivity, accuracy and reliability compare to other conventional method. (Author)

  4. Evaluation for nuclear safety-critical software reliability of DCS

    International Nuclear Information System (INIS)

    Liu Ying

    2015-01-01

    With the development of control and information technology at NPPs, software reliability is important because software failure is usually considered as one form of common cause failures in Digital I and C Systems (DCS). The reliability analysis of DCS, particularly qualitative and quantitative evaluation on the nuclear safety-critical software reliability belongs to a great challenge. To solve this problem, not only comprehensive evaluation model and stage evaluation models are built in this paper, but also prediction and sensibility analysis are given to the models. It can make besement for evaluating the reliability and safety of DCS. (author)

  5. Suitability of analytical methods to measure solubility for the purpose of nanoregulation.

    Science.gov (United States)

    Tantra, Ratna; Bouwmeester, Hans; Bolea, Eduardo; Rey-Castro, Carlos; David, Calin A; Dogné, Jean-Michel; Jarman, John; Laborda, Francisco; Laloy, Julie; Robinson, Kenneth N; Undas, Anna K; van der Zande, Meike

    2016-01-01

    Solubility is an important physicochemical parameter in nanoregulation. If nanomaterial is completely soluble, then from a risk assessment point of view, its disposal can be treated much in the same way as "ordinary" chemicals, which will simplify testing and characterisation regimes. This review assesses potential techniques for the measurement of nanomaterial solubility and evaluates the performance against a set of analytical criteria (based on satisfying the requirements as governed by the cosmetic regulation as well as the need to quantify the concentration of free (hydrated) ions). Our findings show that no universal method exists. A complementary approach is thus recommended, to comprise an atomic spectrometry-based method in conjunction with an electrochemical (or colorimetric) method. This article shows that although some techniques are more commonly used than others, a huge research gap remains, related with the need to ensure data reliability.

  6. Software reliability for safety-critical applications

    International Nuclear Information System (INIS)

    Everett, B.; Musa, J.

    1994-01-01

    In this talk, the authors address the question open-quotes Can Software Reliability Engineering measurement and modeling techniques be applied to safety-critical applications?close quotes Quantitative techniques have long been applied in engineering hardware components of safety-critical applications. The authors have seen a growing acceptance and use of quantitative techniques in engineering software systems but a continuing reluctance in using such techniques in safety-critical applications. The general case posed against using quantitative techniques for software components runs along the following lines: safety-critical applications should be engineered such that catastrophic failures occur less frequently than one in a billion hours of operation; current software measurement/modeling techniques rely on using failure history data collected during testing; one would have to accumulate over a billion operational hours to verify failure rate objectives of about one per billion hours

  7. Safety and reliability criteria

    International Nuclear Information System (INIS)

    O'Neil, R.

    1978-01-01

    Nuclear power plants and, in particular, reactor pressure boundary components have unique reliability requirements, in that usually no significant redundancy is possible, and a single failure can give rise to possible widespread core damage and fission product release. Reliability may be required for availability or safety reasons, but in the case of the pressure boundary and certain other systems safety may dominate. Possible Safety and Reliability (S and R) criteria are proposed which would produce acceptable reactor design. Without some S and R requirement the designer has no way of knowing how far he must go in analysing his system or component, or whether his proposed solution is likely to gain acceptance. The paper shows how reliability targets for given components and systems can be individually considered against the derived S and R criteria at the design and construction stage. Since in the case of nuclear pressure boundary components there is often very little direct experience on which to base reliability studies, relevant non-nuclear experience is examined. (author)

  8. Proposed reliability cost model

    Science.gov (United States)

    Delionback, L. M.

    1973-01-01

    The research investigations which were involved in the study include: cost analysis/allocation, reliability and product assurance, forecasting methodology, systems analysis, and model-building. This is a classic example of an interdisciplinary problem, since the model-building requirements include the need for understanding and communication between technical disciplines on one hand, and the financial/accounting skill categories on the other. The systems approach is utilized within this context to establish a clearer and more objective relationship between reliability assurance and the subcategories (or subelements) that provide, or reenforce, the reliability assurance for a system. Subcategories are further subdivided as illustrated by a tree diagram. The reliability assurance elements can be seen to be potential alternative strategies, or approaches, depending on the specific goals/objectives of the trade studies. The scope was limited to the establishment of a proposed reliability cost-model format. The model format/approach is dependent upon the use of a series of subsystem-oriented CER's and sometimes possible CTR's, in devising a suitable cost-effective policy.

  9. Reliable predictions of waste performance in a geologic repository

    International Nuclear Information System (INIS)

    Pigford, T.H.; Chambre, P.L.

    1985-08-01

    Establishing reliable estimates of long-term performance of a waste repository requires emphasis upon valid theories to predict performance. Predicting rates that radionuclides are released from waste packages cannot rest upon empirical extrapolations of laboratory leach data. Reliable predictions can be based on simple bounding theoretical models, such as solubility-limited bulk-flow, if the assumed parameters are reliably known or defensibly conservative. Wherever possible, performance analysis should proceed beyond simple bounding calculations to obtain more realistic - and usually more favorable - estimates of expected performance. Desire for greater realism must be balanced against increasing uncertainties in prediction and loss of reliability. Theoretical predictions of release rate based on mass-transfer analysis are bounding and the theory can be verified. Postulated repository analogues to simulate laboratory leach experiments introduce arbitrary and fictitious repository parameters and are shown not to agree with well-established theory. 34 refs., 3 figs., 2 tabs

  10. pH-metric solubility. 2: correlation between the acid-base titration and the saturation shake-flask solubility-pH methods.

    Science.gov (United States)

    Avdeef, A; Berger, C M; Brownell, C

    2000-01-01

    The objective of this study was to compare the results of a normal saturation shake-flask method to a new potentiometric acid-base titration method for determining the intrinsic solubility and the solubility-pH profiles of ionizable molecules, and to report the solubility constants determined by the latter technique. The solubility-pH profiles of twelve generic drugs (atenolol, diclofenac.Na, famotidine, flurbiprofen, furosemide, hydrochlorothiazide, ibuprofen, ketoprofen, labetolol.HCl, naproxen, phenytoin, and propranolol.HCl), with solubilities spanning over six orders of magnitude, were determined both by the new pH-metric method and by a traditional approach (24 hr shaking of saturated solutions, followed by filtration, then HPLC assaying with UV detection). The 212 separate saturation shake-flask solubility measurements and those derived from 65 potentiometric titrations agreed well. The analysis produced the correlation equation: log(1/S)titration = -0.063(+/- 0.032) + 1.025(+/- 0.011) log(1/S)shake-flask, s = 0.20, r2 = 0.978. The potentiometrically-derived intrinsic solubilities of the drugs were: atenolol 13.5 mg/mL, diclofenac.Na 0.82 microg/mL, famotidine 1.1 mg/ mL, flurbiprofen 10.6 microg/mL, furosemide 5.9 microg/mL, hydrochlorothiazide 0.70 mg/mL, ibuprofen 49 microg/mL, ketoprofen 118 microg/mL, labetolol.HCl 128 microg/mL, naproxen 14 microg/mL, phenytoin 19 microg/mL, and propranolol.HCl 70 microg/mL. The new potentiometric method was shown to be reliable for determining the solubility-pH profiles of uncharged ionizable drug substances. Its speed compared to conventional equilibrium measurements, its sound theoretical basis, its ability to generate the full solubility-pH profile from a single titration, and its dynamic range (currently estimated to be seven orders of magnitude) make the new pH-metric method an attractive addition to traditional approaches used by preformulation and development scientists. It may be useful even to discovery

  11. Maturity index on reliability: covering non-technical aspects of IEC61508 reliability certification

    International Nuclear Information System (INIS)

    Brombacher, A.C.

    1999-01-01

    One of the more recent developments in the field of reliability and safety is the realisation that these aspects are not only a function of the product itself, but also of the organisation realising this product. A second development is a trend from an often predominantly qualitative analysis towards a quantitative analysis. In contrast to the (older) DIN 0801, the (more recent) IEC61508 requires, on product level, also a quantitative analysis and, on organisational level, an assessment of the lifecycle of a product by analysing the (maturity of the) relevant business processes (DIN V VDE 0801. Grundsaetze fuer Rechner in Systemen mit Sicherheitsaufgaben, 1990; DIN V 0801. Grundlegende Sicherheitsbetrachtungen fuer MSR-Schutzeinrichtungen, 1994; DIN V VDE 0801 A1. Grundsaetze fuer Rechner in Systemen mit Sicherheitsaufgaben, Aenderung A1, 1994; IEC 61508 Functional Safety of electrical/electronic/programmable electronic safety-related systems, draft 4.0, 1997). The IEC standard 61508 covers: (i) technical aspects, both on a quantitative and a qualitative level; (ii) organisational aspects, both on aspects of maturity of business processes (quantitative) and on aspects of the definition and application of procedures (qualitative). This paper shows the necessity for an analysis on all aspects in a safety certification process, and presents an overview of the available tools and techniques for the various quadrants. As methods and tools for especially quadrant C are currently unavailable, this paper will propose a method to assess and improve the maturity of an organisation on reliability management: the maturity index on reliability (MIR)

  12. Quantitative image analysis of synovial tissue

    NARCIS (Netherlands)

    van der Hall, Pascal O.; Kraan, Maarten C.; Tak, Paul Peter

    2007-01-01

    Quantitative image analysis is a form of imaging that includes microscopic histological quantification, video microscopy, image analysis, and image processing. Hallmarks are the generation of reliable, reproducible, and efficient measurements via strict calibration and step-by-step control of the

  13. PIQMIe: A web server for semi-quantitative proteomics data management and analysis

    NARCIS (Netherlands)

    A. Kuzniar (Arnold); R. Kanaar (Roland)

    2014-01-01

    textabstractWe present the Proteomics Identifications and Quantitations Data Management and Integration Service or PIQMIe that aids in reliable and scalable data management, analysis and visualization of semi-quantitative mass spectrometry based proteomics experiments. PIQMIe readily integrates

  14. Reliability Centered Maintenance - Methodologies

    Science.gov (United States)

    Kammerer, Catherine C.

    2009-01-01

    Journal article about Reliability Centered Maintenance (RCM) methodologies used by United Space Alliance, LLC (USA) in support of the Space Shuttle Program at Kennedy Space Center. The USA Reliability Centered Maintenance program differs from traditional RCM programs because various methodologies are utilized to take advantage of their respective strengths for each application. Based on operational experience, USA has customized the traditional RCM methodology into a streamlined lean logic path and has implemented the use of statistical tools to drive the process. USA RCM has integrated many of the L6S tools into both RCM methodologies. The tools utilized in the Measure, Analyze, and Improve phases of a Lean Six Sigma project lend themselves to application in the RCM process. All USA RCM methodologies meet the requirements defined in SAE JA 1011, Evaluation Criteria for Reliability-Centered Maintenance (RCM) Processes. The proposed article explores these methodologies.

  15. Issues in cognitive reliability

    International Nuclear Information System (INIS)

    Woods, D.D.; Hitchler, M.J.; Rumancik, J.A.

    1984-01-01

    This chapter examines some problems in current methods to assess reactor operator reliability at cognitive tasks and discusses new approaches to solve these problems. The two types of human failures are errors in the execution of an intention and errors in the formation/selection of an intention. Topics considered include the types of description, error correction, cognitive performance and response time, the speed-accuracy tradeoff function, function based task analysis, and cognitive task analysis. One problem of human reliability analysis (HRA) techniques in general is the question of what are the units of behavior whose reliability are to be determined. A second problem for HRA is that people often detect and correct their errors. The use of function based analysis, which maps the problem space for plant control, is recommended

  16. Reliability issues in PACS

    Science.gov (United States)

    Taira, Ricky K.; Chan, Kelby K.; Stewart, Brent K.; Weinberg, Wolfram S.

    1991-07-01

    Reliability is an increasing concern when moving PACS from the experimental laboratory to the clinical environment. Any system downtime may seriously affect patient care. The authors report on the several classes of errors encountered during the pre-clinical release of the PACS during the past several months and present the solutions implemented to handle them. The reliability issues discussed include: (1) environmental precautions, (2) database backups, (3) monitor routines of critical resources and processes, (4) hardware redundancy (networks, archives), and (5) development of a PACS quality control program.

  17. Reliability Parts Derating Guidelines

    Science.gov (United States)

    1982-06-01

    226-30, October 1974. 66 I, 26. "Reliability of GAAS Injection Lasers", De Loach , B. C., Jr., 1973 IEEE/OSA Conference on Laser Engineering and...Vol. R-23, No. 4, 226-30, October 1974. 28. "Reliability of GAAS Injection Lasers", De Loach , B. C., Jr., 1973 IEEE/OSA Conference on Laser...opnatien ot 󈨊 deg C, mounted on a 4-inach square 0.250~ inch thick al~loy alum~nusi panel.. This mounting technique should be L~ ken into cunoidur~tiou

  18. Recommendations for certification or measurement of reliability for reliable digital archival repositories with emphasis on access

    Directory of Open Access Journals (Sweden)

    Paula Regina Ventura Amorim Gonçalez

    2017-04-01

    Full Text Available Introduction: Considering the guidelines of ISO 16363: 2012 (Space data and information transfer systems -- Audit and certification of trustworthy digital repositories and the text of CONARQ Resolution 39 for certification of Reliable Digital Archival Repository (RDC-Arq, verify the technical recommendations should be used as the basis for a digital archival repository to be considered reliable. Objective: Identify requirements for the creation of Reliable Digital Archival Repositories with emphasis on access to information from the ISO 16363: 2012 and CONARQ Resolution 39. Methodology: For the development of the study, the methodology consisted of an exploratory, descriptive and documentary theoretical investigation, since it is based on ISO 16363: 2012 and CONARQ Resolution 39. From the perspective of the problem approach, the study is qualitative and quantitative, since the data were collected, tabulated, and analyzed from the interpretation of their contents. Results: We presented a set of Checklist Recommendations for reliability measurement and/or certification for RDC-Arq with a clipping focused on the identification of requirements with emphasis on access to information is presented. Conclusions: The right to information as well as access to reliable information is a premise for Digital Archival Repositories, so the set of recommendations is directed to archivists who work in Digital Repositories and wish to verify the requirements necessary to evaluate the reliability of the Digital Repository or still guide the information professional in collecting requirements for repository reliability certification.

  19. IUPAC-NIST Solubility Data Series. 100. Rare Earth Metal Fluorides in Water and Aqueous Systems. Part 3. Heavy Lanthanides (Gd–Lu)

    Energy Technology Data Exchange (ETDEWEB)

    Mioduski, Tomasz [Institute of Nuclear Chemistry and Technology, 03195 Warszawa (Poland); Gumiński, Cezary, E-mail: cegie@chem.uw.edu.pl [Department of Chemistry, University of Warsaw, 02093 Warszawa (Poland); Zeng, Dewen, E-mail: dewen-zeng@hotmail.com [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China)

    2015-06-15

    This is the third part of the volume devoted to solubility data for the rare earth metal (REM) fluorides in water and in aqueous ternary and multicomponent systems. It covers experimental results of trivalent fluorides of Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu (so-called heavy lanthanides), since no quantitative data on solubilities of TbF{sub 4} and YbF{sub 2} (the most stable compounds at these valencies) are available. The related literature has been covered through the end of 2014. Compilations of all available papers with the solubility data are introduced for each REM fluoride with a corresponding critical evaluation. Every such assessment contains a collection of all solubility results in aqueous solution, a selection of suggested solubility data, a solubility equation, and a brief discussion of the multicomponent systems. Only simple fluorides (no complexes or double salts) are treated as the input substances in this report. General features of the systems, such as nature of the equilibrium solid phases, solubility as a function of temperature, influence of ionic strength, solution pH, mixed solvent medium on the solubility, quality of the solubility results, and the solubility as a function of REM atomic number, have already been presented in Part 1 of the volume.

  20. Solubility study of Tc(IV) oxides

    International Nuclear Information System (INIS)

    Liu, D.J.; Fan, X.H.

    2005-01-01

    The deep geological disposal of the high level radioactive wastes is expected to be a safer disposal method in most countries. The long-lived fission product 99 Tc is present in large quantities in nuclear wastes and its chemical behavior in aqueous solution is of considerable interest. Under oxidizing conditions technetium exists as the anionic species TcO 4 - whereas under the reducing conditions, expected to exist in a deep geological repository, it is generally predicted that technetium will be present as TcO 2 ·nH 2 O. Hence, the mobility of Tc(IV) in reducing groundwater may be limited by the solubility of TcO 2 ·nH 2 O under these conditions. Due to this fact it is important to investigate the solubility of TcO 2 ·nH 2 O. The solubility determines the release of radionuclides from waste form and is used as a source term in radionuclide migration analysis in performance assessment of radioactive waste repository. Technetium oxide was prepared by reduction of a technetate solution with Sn 2 + . The solubility of Tc(IV) oxide has been determined in simulated groundwater and redistilled water under aerobic and anaerobic conditions. The effects of pH and CO 3 2- concentration of solution on solubility of Tc(IV) oxide were studied. The concentration of total technetium and Tc(IV) species in the solutions were periodically determined by separating the oxidized and reduced technetium species using a solvent extraction procedure and counting the beta activity of the 99 Tc with a liquid scintillation counter. The experimental results show that the rate of oxidation of Tc(IV) in simulated groundwater and redistilled water is about (1.49-1.86) x 10 -9 mol/(L·d) under aerobic conditions, but Tc(IV) in simulated groundwater and redistilled water is not oxidized under anaerobic conditions. Under aerobic or anaerobic conditions the solubility of Tc(IV) oxide in simulated groundwater and redistilled water is equal on the whole after centrifugation or ultrafiltration. The

  1. Product reliability and thin-film photovoltaics

    Science.gov (United States)

    Gaston, Ryan; Feist, Rebekah; Yeung, Simon; Hus, Mike; Bernius, Mark; Langlois, Marc; Bury, Scott; Granata, Jennifer; Quintana, Michael; Carlson, Carl; Sarakakis, Georgios; Ogden, Douglas; Mettas, Adamantios

    2009-08-01

    Despite significant growth in photovoltaics (PV) over the last few years, only approximately 1.07 billion kWhr of electricity is estimated to have been generated from PV in the US during 2008, or 0.27% of total electrical generation. PV market penetration is set for a paradigm shift, as fluctuating hydrocarbon prices and an acknowledgement of the environmental impacts associated with their use, combined with breakthrough new PV technologies, such as thin-film and BIPV, are driving the cost of energy generated with PV to parity or cost advantage versus more traditional forms of energy generation. In addition to reaching cost parity with grid supplied power, a key to the long-term success of PV as a viable energy alternative is the reliability of systems in the field. New technologies may or may not have the same failure modes as previous technologies. Reliability testing and product lifetime issues continue to be one of the key bottlenecks in the rapid commercialization of PV technologies today. In this paper, we highlight the critical need for moving away from relying on traditional qualification and safety tests as a measure of reliability and focus instead on designing for reliability and its integration into the product development process. A drive towards quantitative predictive accelerated testing is emphasized and an industrial collaboration model addressing reliability challenges is proposed.

  2. Cocrystals to facilitate delivery of poorly soluble compounds beyond-rule-of-5.

    Science.gov (United States)

    Kuminek, Gislaine; Cao, Fengjuan; Bahia de Oliveira da Rocha, Alanny; Gonçalves Cardoso, Simone; Rodríguez-Hornedo, Naír

    2016-06-01

    Besides enhancing aqueous solubilities, cocrystals have the ability to fine-tune solubility advantage over drug, supersaturation index, and bioavailability. This review presents important facts about cocrystals that set them apart from other solid-state forms of drugs, and a quantitative set of rules for the selection of additives and solution/formulation conditions that predict cocrystal solubility, supersaturation index, and transition points. Cocrystal eutectic constants are shown to be the most important cocrystal property that can be measured once a cocrystal is discovered, and simple relationships are presented that allow for prediction of cocrystal behavior as a function of pH and drug solubilizing agents. Cocrystal eutectic constant is a stability or supersatuation index that: (a) reflects how close or far from equilibrium a cocrystal is, (b) establishes transition points, and (c) provides a quantitative scale of cocrystal true solubility changes over drug. The benefit of this strategy is that a single measurement, that requires little material and time, provides a principled basis to tailor cocrystal supersaturation index by the rational selection of cocrystal formulation, dissolution, and processing conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Measurement and ANN prediction of pH-dependent solubility of nitrogen-heterocyclic compounds.

    Science.gov (United States)

    Sun, Feifei; Yu, Qingni; Zhu, Jingke; Lei, Lecheng; Li, Zhongjian; Zhang, Xingwang

    2015-09-01

    Based on the solubility of 25 nitrogen-heterocyclic compounds (NHCs) measured by saturation shake-flask method, artificial neural network (ANN) was employed to the study of the quantitative relationship between the structure and pH-dependent solubility of NHCs. With genetic algorithm-multivariate linear regression (GA-MLR) approach, five out of the 1497 molecular descriptors computed by Dragon software were selected to describe the molecular structures of NHCs. Using the five selected molecular descriptors as well as pH and the partial charge on the nitrogen atom of NHCs (QN) as inputs of ANN, a quantitative structure-property relationship (QSPR) model without using Henderson-Hasselbalch (HH) equation was successfully developed to predict the aqueous solubility of NHCs in different pH water solutions. The prediction model performed well on the 25 model NHCs with an absolute average relative deviation (AARD) of 5.9%, while HH approach gave an AARD of 36.9% for the same model NHCs. It was found that QN played a very important role in the description of NHCs and, with QN, ANN became a potential tool for the prediction of pH-dependent solubility of NHCs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Columbus safety and reliability

    Science.gov (United States)

    Longhurst, F.; Wessels, H.

    1988-10-01

    Analyses carried out to ensure Columbus reliability, availability, and maintainability, and operational and design safety are summarized. Failure modes/effects/criticality is the main qualitative tool used. The main aspects studied are fault tolerance, hazard consequence control, risk minimization, human error effects, restorability, and safe-life design.

  5. Reliability versus reproducibility

    International Nuclear Information System (INIS)

    Lautzenheiser, C.E.

    1976-01-01

    Defect detection and reproducibility of results are two separate but closely related subjects. It is axiomatic that a defect must be detected from examination to examination or reproducibility of results is very poor. On the other hand, a defect can be detected on each of subsequent examinations for higher reliability and still have poor reproducibility of results

  6. Power transformer reliability modelling

    NARCIS (Netherlands)

    Schijndel, van A.

    2010-01-01

    Problem description Electrical power grids serve to transport and distribute electrical power with high reliability and availability at acceptable costs and risks. These grids play a crucial though preferably invisible role in supplying sufficient power in a convenient form. Today’s society has

  7. Designing reliability into accelerators

    International Nuclear Information System (INIS)

    Hutton, A.

    1992-08-01

    For the next generation of high performance, high average luminosity colliders, the ''factories,'' reliability engineering must be introduced right at the inception of the project and maintained as a central theme throughout the project. There are several aspects which will be addressed separately: Concept; design; motivation; management techniques; and fault diagnosis

  8. Proof tests on reliability

    International Nuclear Information System (INIS)

    Mishima, Yoshitsugu

    1983-01-01

    In order to obtain public understanding on nuclear power plants, tests should be carried out to prove the reliability and safety of present LWR plants. For example, the aseismicity of nuclear power plants must be verified by using a large scale earthquake simulator. Reliability test began in fiscal 1975, and the proof tests on steam generators and on PWR support and flexure pins against stress corrosion cracking have already been completed, and the results have been internationally highly appreciated. The capacity factor of the nuclear power plant operation in Japan rose to 80% in the summer of 1983, and considering the period of regular inspection, it means the operation of almost full capacity. Japanese LWR technology has now risen to the top place in the world after having overcome the defects. The significance of the reliability test is to secure the functioning till the age limit is reached, to confirm the correct forecast of deteriorating process, to confirm the effectiveness of the remedy to defects and to confirm the accuracy of predicting the behavior of facilities. The reliability of nuclear valves, fuel assemblies, the heat affected zones in welding, reactor cooling pumps and electric instruments has been tested or is being tested. (Kako, I.)

  9. Reliability and code level

    NARCIS (Netherlands)

    Kasperski, M.; Geurts, C.P.W.

    2005-01-01

    The paper describes the work of the IAWE Working Group WBG - Reliability and Code Level, one of the International Codification Working Groups set up at ICWE10 in Copenhagen. The following topics are covered: sources of uncertainties in the design wind load, appropriate design target values for the

  10. Reliability of Plastic Slabs

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    1989-01-01

    In the paper it is shown how upper and lower bounds for the reliability of plastic slabs can be determined. For the fundamental case it is shown that optimal bounds of a deterministic and a stochastic analysis are obtained on the basis of the same failure mechanisms and the same stress fields....

  11. Reliability based structural design

    NARCIS (Netherlands)

    Vrouwenvelder, A.C.W.M.

    2014-01-01

    According to ISO 2394, structures shall be designed, constructed and maintained in such a way that they are suited for their use during the design working life in an economic way. To fulfil this requirement one needs insight into the risk and reliability under expected and non-expected actions. A

  12. Travel time reliability modeling.

    Science.gov (United States)

    2011-07-01

    This report includes three papers as follows: : 1. Guo F., Rakha H., and Park S. (2010), "A Multi-state Travel Time Reliability Model," : Transportation Research Record: Journal of the Transportation Research Board, n 2188, : pp. 46-54. : 2. Park S.,...

  13. Reliability and Model Fit

    Science.gov (United States)

    Stanley, Leanne M.; Edwards, Michael C.

    2016-01-01

    The purpose of this article is to highlight the distinction between the reliability of test scores and the fit of psychometric measurement models, reminding readers why it is important to consider both when evaluating whether test scores are valid for a proposed interpretation and/or use. It is often the case that an investigator judges both the…

  14. Parametric Mass Reliability Study

    Science.gov (United States)

    Holt, James P.

    2014-01-01

    The International Space Station (ISS) systems are designed based upon having redundant systems with replaceable orbital replacement units (ORUs). These ORUs are designed to be swapped out fairly quickly, but some are very large, and some are made up of many components. When an ORU fails, it is replaced on orbit with a spare; the failed unit is sometimes returned to Earth to be serviced and re-launched. Such a system is not feasible for a 500+ day long-duration mission beyond low Earth orbit. The components that make up these ORUs have mixed reliabilities. Components that make up the most mass-such as computer housings, pump casings, and the silicon board of PCBs-typically are the most reliable. Meanwhile components that tend to fail the earliest-such as seals or gaskets-typically have a small mass. To better understand the problem, my project is to create a parametric model that relates both the mass of ORUs to reliability, as well as the mass of ORU subcomponents to reliability.

  15. Influence of milling process on efavirenz solubility

    Directory of Open Access Journals (Sweden)

    Erizal Zaini

    2017-01-01

    Full Text Available Introduction: The aim of this study was to investigate the influence of the milling process on the solubility of efavirenz. Materials and Methods: Milling process was done using Nanomilling for 30, 60, and 180 min. Intact and milled efavirenz were characterized by powder X-ray diffraction, scanning electron microscopy (SEM, spectroscopy infrared (IR, differential scanning calorimetry (DSC, and solubility test. Results: The X-ray diffractogram showed a decline on peak intensity of milled efavirenz compared to intact efavirenz. The SEM graph depicted the change from crystalline to amorphous habit after milling process. The IR spectrum showed there was no difference between intact and milled efavirenz. Thermal analysis which performed by DSC showed a reduction on endothermic peak after milling process which related to decreasing of crystallinity. Solubility test of intact and milled efavirenz was conducted in distilled water free CO2with 0.25% sodium lauryl sulfate media and measured using high-performance liquid chromatography method with acetonitrile: distilled water (80:20 as mobile phases. The solubility was significantly increased (P < 0.05 after milling processes, which the intact efavirenz was 27.12 ± 2.05, while the milled efavirenz for 30, 60, and 180 min were 75.53 ± 1.59, 82.34 ± 1.23, and 104.75 ± 0.96 μg/mL, respectively. Conclusions: Based on the results, the solubility of efavirenz improved after milling process.

  16. Solubility of lithium deuteride in liquid lithium

    International Nuclear Information System (INIS)

    Veleckis, E.; Yonco, R.M.; Maroni, V.A.

    1977-01-01

    The solubility of LiD in liquid lithium between the eutectic and monotectic temperatures was measured using a direct sampling method. Solubilities were found to range from 0.0154 mol.% LiD at 199 0 C to 3.32 mol.% LiD at 498 0 C. The data were used in the derivation of an expression for the activity coefficient of LiD as a function of temperature and composition and an equation relating deuteride solubility and temperature, thus defining the liquidus curve. Similar equations were also derived for the Li-LiH system using the existing solubility data. Extrapolation of the liquidus curves yielded the eutectic concentrations (0.040 mol.% LiH and 0.035 mol.% LiD) and the freezing point depressions (0.23 0 C for Li-LiH and 0.20 0 C for Li-LiD) at the eutectic point. The results are compared with the literature data for hydrogen and deuterium. The implications of the relatively high solubility of hydrogen isotopes in lithium just above the melting point are discussed with respect to the cold trapping of tritium in fusion reactor blankets. (Auth.)

  17. Solubility studies of Np(IV)

    International Nuclear Information System (INIS)

    Zhang Yingjie; Yao Jun; Jiao Haiyang; Ren Lihong; Zhou Duo; Fan Xianhua

    2001-01-01

    The solubility of Np(IV) in simulated underground water and redistilled water has been measured with the variations of pH(6-12) and storage time (0-100 d) in the presence of reductant (Na 2 S 2 O 4 , metallic Fe). All experiments are performed in a low oxygen concentration glove box containing high purity Ar(99.99%), with an oxygen content of less than 5 x 10 -6 mol/mol. Experimental results show that the variation of pH in solution has little effect on the solubility of Np(IV) in the two kinds of water; the measured solubility of Np(IV) is affected by the composition of solution; with Na 2 S 2 O 4 as a reductant, the solubility of Np(IV) in simulated underground water is (9.23 +- 0.48) x 10 -10 mol/L, and that in redistilled water is (8.31 +- 0.35) x 10 -10 mol/L; with metallic Fe as a reductant, the solubility of Np(IV) in simulated underground water is (1.85 +- 0.56) x 10 -9 mol/L, and that in redistilled water is (1.48 +- 0.66) x 10 -9 mol/L

  18. Solubility of pllutonium in alkaline salt solutions

    International Nuclear Information System (INIS)

    Hobbs, D.T.; Edwards, T.B.

    1993-01-01

    Plutonium solubility data from several studies have been evaluated. For each data set, a predictive model has been developed where appropriate. In addition, a statistical model and corresponding prediction intervals for plutonium solubility as a quadratic function of the hydroxide concentration have been developed. Because of the wide range of solution compositions, the solubility of plutonium can vary by as much as three orders of magnitude for any given hydroxide concentration and still remain within the prediction interval. Any nuclear safety assessments that depend on the maximum amount of plutonium dissolved in alkaline salt solutions should use concentrations at least as great as the upper prediction limits developed in this study. To increase the confidence in the prediction model, it is recommended that additional solubility tests be conducted at low hydroxide concentrations and with all of the other solution components involved. To validate the model for application to actual waste solutions, it is recommended that the plutonium solubilities in actual waste solutions be determined and compared to the values predicted by the quadratic model

  19. Magnetite solubility studies under simulated PWR primary-side conditions, using lithiated, hydrogenated water

    International Nuclear Information System (INIS)

    Hewett, John; Morrison, Jonathan; Cooper, Christopher; Ponton, Clive; Connolly, Brian; Dickinson, Shirley; Henshaw, Jim

    2014-01-01

    As software for modelling dissolution, precipitation, and transport of metallic species and subsequent CRUD deposition within nuclear plant becomes more advanced, there is an increasing need for accurate and reliable thermodynamic data. The solubility behaviour of magnetite is an example of such data, and is central to any treatment of CRUD solubility due to the prevalence of magnetite and nickel ferrites in CRUD. Several workers have shown the most consistent solubility data comes from once-through flowing systems. However, despite a strong consensus between the results in acidic to mildly alkaline solutions, there is disagreement between the results at approximately pH 25C 9 and higher. A programme of experimental work is on-going at the University of Birmingham, focusing on solubility of metal oxides (e.g., magnetite) in conditions relevant to PWR primary coolant. One objective of this programme is to calculate thermodynamic constants from the data obtained. Magnetite solubility from 200 to 300°C, in lithiated, hydrogenated water of pH 25C 9–11 is being studied using a once-through rig constructed of 316L stainless steel. The feedwater is pumped at 100 bar pressure through a heated bed of magnetite granules, and the output solution is collected and analysed for iron and several other metals by ICP-MS. This paper presents results from preliminary tests without magnetite granules, in which the corroding surface of the rig itself was used as the sole source of soluble iron and of dissolved hydrogen. Levels of iron were generally within an order of magnitude of literature solubility values. Comparison of results at different flow rates and temperatures, in conjunction with conclusions drawn from the published literature, suggests that this is likely due to the presence of particulate matter in a greatly under-saturated solution, compensating for the low surface area of oxide in contact with the solution. (author)

  20. Aryl-derivatized, water-soluble functionalized carbon nanotubes for biomedical applications

    International Nuclear Information System (INIS)

    Karousis, N.; Ali-Boucetta, H.; Kostarelos, K.; Tagmatarchis, N.

    2008-01-01

    The functionalization of very-thin multi-walled carbon nanotubes (VT-MWNTs) with an aniline derivative, via the protocol of in situ generated aryl diazonium salts results, upon acidic deprotection of the terminal BOC group, on the formation of the water-soluble positively charged ammonium functionalized VT-MWNTs-NH 3 + material. The new materials have been structurally and morphologically characterized by infra-red (ATR-IR) spectroscopy and transmission electron microscopy (TEM). The quantitative calculation of the grafted aryl units onto the skeleton of VT-MWNTs has been estimated by thermogravimetric analysis (TGA), while the quantitative Kaiser test showed the amine group loaded onto VT-MWNTs-NH 3 + material. The aqueous solubility of this material has allowed the performance of some initial toxicological in vitro investigations

  1. NASA Applications and Lessons Learned in Reliability Engineering

    Science.gov (United States)

    Safie, Fayssal M.; Fuller, Raymond P.

    2011-01-01

    Since the Shuttle Challenger accident in 1986, communities across NASA have been developing and extensively using quantitative reliability and risk assessment methods in their decision making process. This paper discusses several reliability engineering applications that NASA has used over the year to support the design, development, and operation of critical space flight hardware. Specifically, the paper discusses several reliability engineering applications used by NASA in areas such as risk management, inspection policies, components upgrades, reliability growth, integrated failure analysis, and physics based probabilistic engineering analysis. In each of these areas, the paper provides a brief discussion of a case study to demonstrate the value added and the criticality of reliability engineering in supporting NASA project and program decisions to fly safely. Examples of these case studies discussed are reliability based life limit extension of Shuttle Space Main Engine (SSME) hardware, Reliability based inspection policies for Auxiliary Power Unit (APU) turbine disc, probabilistic structural engineering analysis for reliability prediction of the SSME alternate turbo-pump development, impact of ET foam reliability on the Space Shuttle System risk, and reliability based Space Shuttle upgrade for safety. Special attention is given in this paper to the physics based probabilistic engineering analysis applications and their critical role in evaluating the reliability of NASA development hardware including their potential use in a research and technology development environment.

  2. 40 CFR Table 7 to Subpart Vvvvvv... - Partially Soluble HAP

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Partially Soluble HAP 7 Table 7 to... Pt. 63, Subpt. VVVVVV, Table 7 Table 7 to Subpart VVVVVV of Part 63—Partially Soluble HAP As required... partially soluble HAP listed in the following table. Partially soluble HAP name CAS No. 1. 1,1,1...

  3. Interlaboratory validation of small-scale solubility and dissolution measurements of poorly water-soluble drugs

    DEFF Research Database (Denmark)

    Andersson, Sara B. E.; Alvebratt, Caroline; Bevernage, Jan

    2016-01-01

    The purpose of this study was to investigate the interlaboratory variability in determination of apparent solubility (Sapp) and intrinsic dissolution rate (IDR) using a miniaturized dissolution instrument. Three poorly water-soluble compounds were selected as reference compounds and measured at m...

  4. Effect of cyclodextrin complexation on the aqueous solubility and solubility/dose ratio of praziquantel.

    Science.gov (United States)

    Maragos, Stratos; Archontaki, Helen; Macheras, Panos; Valsami, Georgia

    2009-01-01

    Praziquantel (PZQ), the primary drug of choice in the treatment of schistosomiasis, is a highly lipophilic drug that possesses high permeability and low aqueous solubility and is, therefore, classified as a Class II drug according to the Biopharmaceutics Classification System (BCS). In this work, beta-cyclodextrin (beta-CD) and hydroxypropyl-beta-cyclodextrin (HP-beta-CD) were used in order to determine whether increasing the aqueous solubility of a drug by complexation with CDs, a BCS-Class II compound like PZQ could behave as BCS-Class I (highly soluble/highly permeable) drug. Phase solubility and the kneading and lyophilization techniques were used for inclusion complex preparation; solubility was determined by UV spectroscopy. The ability of the water soluble polymer polyvinylpyrolidone (PVP) to increase the complexation and solubilization efficiency of beta-CD and HP-beta-CD for PZQ was examined. Results showed significant improvement of PZQ solubility in the presence of both cyclodextrins but no additional effect in the presence of PVP. The solubility/dose ratios values of PZQ-cyclodextrin complexes calculated considering the low (150 mg) and the high dose (600 mg) of PZQ, used in practice, indicate that PZQ complexation with CDs may result in drug dosage forms that would behave as a BCS-Class I depending on the administered dose.

  5. Reliability Approach of a Compressor System using Reliability Block ...

    African Journals Online (AJOL)

    pc

    2018-03-05

    Mar 5, 2018 ... This paper presents a reliability analysis of such a system using reliability ... Keywords-compressor system, reliability, reliability block diagram, RBD .... the same structure has been kept with the three subsystems: air flow, oil flow and .... and Safety in Engineering Design", Springer, 2009. [3] P. O'Connor ...

  6. Simultaneous quantification of 21 water soluble vitamin circulating forms in human plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Meisser Redeuil, Karine; Longet, Karin; Bénet, Sylvie; Munari, Caroline; Campos-Giménez, Esther

    2015-11-27

    This manuscript reports a validated analytical approach for the quantification of 21 water soluble vitamins and their main circulating forms in human plasma. Isotope dilution-based sample preparation consisted of protein precipitation using acidic methanol enriched with stable isotope labelled internal standards. Separation was achieved by reversed-phase liquid chromatography and detection performed by tandem mass spectrometry in positive electrospray ionization mode. Instrumental lower limits of detection and quantification reached water soluble vitamins in human plasma single donor samples. The present report provides a sensitive and reliable approach for the quantification of water soluble vitamins and main circulating forms in human plasma. In the future, the application of this analytical approach will give more confidence to provide a comprehensive assessment of water soluble vitamins nutritional status and bioavailability studies in humans. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Preliminary investigation on reliability assessment of passive safety system

    International Nuclear Information System (INIS)

    Huang Changfan; Kuang Bo

    2012-01-01

    The reliability evaluation of passive safety system plays an important part in probabilistic safety assessment (PSA) of nuclear power plant applying passive safety design, which depends quantitatively on reliabilities of passive safety system. According to the object of reliability assessment of passive safety system, relevant parameters are identified. Then passive system behavior during accident scenarios are studied. A practical example of this method is given for the case of reliability assessment of AP1000 passive heat removal system in loss of normal feedwater accident. Key and design parameters of PRHRS are identified and functional failure criteria are established. Parameter combinations acquired by Latin hyper~ cube sampling (LHS) in possible parametric ranges are input and calculations of uncertainty propagation through RELAP5/MOD3 code are carried out. Based on the calculations, sensitivity assessment on PRHRS functional criteria and reliability evaluation of the system are presented, which might provide further PSA with PRHR system reliability. (authors)

  8. Reliability and Rankings

    NARCIS (Netherlands)

    K.Y. Lam (Kar Yin)

    2011-01-01

    textabstractQuestionnaires are an important way to gather information about large populations for both qualitative and quantitative research. Hence, the value of a good questionnaire design and the quality of questionnaire data cannot be emphasized enough. This thesis discusses some aspects of the

  9. Molecular dynamics simulations of zinc oxide solubility: From bulk down to nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Escorihuela, Laura; Fernández, Alberto; Rallo, Robert; Martorell, Benjamí

    2018-02-01

    The solubility of metal oxides is one of the key descriptors for the evaluation of their potential toxic effects, both in the bulk form and in nanoparticulated aggregates. Current work presents a new methodology for the in silico assessment of the solubility of metal oxides, which is demonstrated using a well-studied system, ZnO. The calculation of the solubility is based on statistical thermodynamics tools combined with Density Functional Tight Binding theory for the evaluation of the free energy exchange during the dissolution process. Models of small ZnO clusters are used for describing the final dissolved material, since the complete ionic dissolution of ZnO is hindered by the formation of O2- anions in solution, which are highly unstable. Results show very good agreement between the computed solubility values and experimental data for ZnO bulk, up to 0.5 mg·L-1 and equivalents of 50 g·L-1 for the free Zn2+ cation in solution. However, the reference model for solid nanoparticles formed by free space nanoparticles can only give a limited quantitative solubility evaluation for ZnO nanoparticles.

  10. Relationship between Molecular Structure Characteristics of Feed Proteins and Protein Digestibility and Solubility

    Directory of Open Access Journals (Sweden)

    Mingmei Bai

    2016-08-01

    Full Text Available The nutritional value of feed proteins and their utilization by livestock are related not only to the chemical composition but also to the structure of feed proteins, but few studies thus far have investigated the relationship between the structure of feed proteins and their solubility as well as digestibility in monogastric animals. To address this question we analyzed soybean meal, fish meal, corn distiller’s dried grains with solubles, corn gluten meal, and feather meal by Fourier transform infrared (FTIR spectroscopy to determine the protein molecular spectral band characteristics for amides I and II as well as α-helices and β-sheets and their ratios. Protein solubility and in vitro digestibility were measured with the Kjeldahl method using 0.2% KOH solution and the pepsin-pancreatin two-step enzymatic method, respectively. We found that all measured spectral band intensities (height and area of feed proteins were correlated with their the in vitro digestibility and solubility (p≤0.003; moreover, the relatively quantitative amounts of α-helices, random coils, and α-helix to β-sheet ratio in protein secondary structures were positively correlated with protein in vitro digestibility and solubility (p≤0.004. On the other hand, the percentage of β-sheet structures was negatively correlated with protein in vitro digestibility (p<0.001 and solubility (p = 0.002. These results demonstrate that the molecular structure characteristics of feed proteins are closely related to their in vitro digestibility at 28 h and solubility. Furthermore, the α-helix-to-β-sheet ratio can be used to predict the nutritional value of feed proteins.

  11. Solubilities of boric acid in heavy water

    International Nuclear Information System (INIS)

    Nakai, Shigetsugu; Aoi, Hideki; Hayashi, Ken-ichi; Katoh, Taizo; Watanabe, Takashi.

    1988-01-01

    A gravimetric analysis using meta-boric acid (HBO 2 or DBO 2 ) as a weighing form has been developed for solubility measurement. The method gave satisfactory results in preliminary measurement of solubilities of boric acid in light water. By using this method, the solubilities of 10 B enriched D 3 BO 3 in heavy water were measured. The results are as follows; 2.67 (7deg C), 3.52 (15deg C), 5.70 (30deg C), 8.87 (50deg C) and 12.92 (70deg C) w/o, respectively. These values are about 10% lower than those in light water. Thermodynamical consideration based on the data shows that boric acid is the water structure breaker. (author)

  12. Resveratrol cocrystals with enhanced solubility and tabletability.

    Science.gov (United States)

    Zhou, Zhengzheng; Li, Wanying; Sun, Wei-Jhe; Lu, Tongbu; Tong, Henry H Y; Sun, Changquan Calvin; Zheng, Ying

    2016-07-25

    Two new 1:1 cocrystals of resveratrol (RES) with 4-aminobenzamide (RES-4ABZ) and isoniazid (RES-ISN) were synthesized by liquid assisted grinding (LAG) and rapid solvent removal (RSR) methods using ethanol as solvent. Their physiochemical properties were characterized using PXRD, DSC, solid state and solution NMR, FT-IR, and HPLC. Pharmaceutically relevant properties, including tabletability, solubility, intrinsic dissolution rate, and hygroscopicity, were evaluated. Temperature-composition phase diagram for RES-ISN cocrystal system was constructed from DSC data. Both cocrystals show higher solubility than resveratrol over a broad range of pH. They are phase stable and non-hygroscopic even under high humidity conditions. Importantly, both cocrystals exhibit improved solubility and tabletability compared with RES, which make them more suitable candidates for tablet formulation development. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. AW-101 entrained solids - Solubility versus temperature

    International Nuclear Information System (INIS)

    GJ Lumetta; RC Lettau; GF Piepel

    2000-01-01

    This report describes the results of a test conducted by Battelle to assess the solubility of the solids entrained in the diluted AW-101 low-activity waste (LAW) sample. BNFL requested Battelle to dilute the AW-1-1 sample using de-ionized water to mimic expected plant operating conditions. BNFL further requested Battelle to assess the solubility of the solids present in the diluted AW-101 sample versus temperature conditions of 30, 40, and 50 C. BNFL requested these tests to assess the composition of the LAW supernatant and solids versus expected plant-operating conditions. The work was conducted according to test plan BNFL-TP-29953-7, Rev. 0, Determination of the Solubility of LAW Entrained Solids. The test went according to plan, with no deviations from the test plan

  14. Solubility and stability of inorganic carbonates

    International Nuclear Information System (INIS)

    Taylor, P.

    1987-01-01

    The chemistry of inorganic carbonates is reviewed, with emphasis on solubility and hydrolytic stability, in order to identify candidate waste forms for immobilization and disposal of 14 C. At present, CaCO 3 and BaCO 3 are the two most widely favoured wasted forms, primarily because they are the products of proven CO 2 -scrubbing technology. However, they have relatively high solubilities in non-alkaline solutions, necessitating care in selecting and assessing an appropriate disposal environment. Three compounds with better solubility characteristics in near-neutral waters are identified: bismutite, (BiO) 2 CO 3 ; hydrocerussite, Pb 3 (OH) 2 (CO 3 ) 2 ; and rhodochrosite, MnCO 3 . Some of the limitations of each of these alternative waste forms are discussed

  15. A framework for API solubility modelling

    DEFF Research Database (Denmark)

    Conte, Elisa; Gani, Rafiqul; Crafts, Peter

    . In addition, most of the models are not predictive and requires experimental data for the calculation of the needed parameters. This work aims at developing an efficient framework for the solubility modelling of Active Pharmaceutical Ingredients (API) in water and organic solvents. With this framework......-SAFT) are used for solubility calculations when the needed interaction parameters or experimental data are available. The CI-UNIFAC is instead used when the previous models lack interaction parameters or when solubility data are not available. A new GC+ model for APIs solvent selection based...... on the hydrophobicity, hydrophilicity and polarity information of the API and solvent is also developed, for performing fast solvent selection and screening. Eventually, all the previous developments are integrated in a framework for their efficient and integrated use. Two case studies are presented: the first...

  16. Solubility of iron in liquid lead

    International Nuclear Information System (INIS)

    Ali-Khan, I.

    1981-01-01

    The use of liquid lead in high temperature chemical and metallurgical processes is well known. The structural materials applied for the containment of these processes are either iron base alloys or possess iron as an alloying element. Besides that, lead itself is alloyed in some steels to achieve some very useful properties. For understanding the effect of liquid lead in such structural materials, it is important to determine the solubility of iron in liquid lead which would also be indicative of the stability of these alloys. At the institute of reactor materials of KFA Juelich, investigations have been conducted to determine the solubility of iron in liquid lead up to a temperature of about 1000 0 C. In this presentation the data concerning the solubility of iron in liquid lead are brought up to date and discussed including the results of our previous investigations. (orig.)

  17. Equilibrium Solubility of CO2 in Alkanolamines

    DEFF Research Database (Denmark)

    Waseem Arshad, Muhammad; Fosbøl, Philip Loldrup; von Solms, Nicolas

    2014-01-01

    Equilibrium solubility of CO2 were measured in aqueous solutions of Monoethanolamine (MEA) and N,N-diethylethanolamine(DEEA). Equilibrium cells are generally used for these measurements. In this study, the equilibrium data were measured from the calorimetry. For this purpose a reaction calorimeter...... (model CPA 122 from ChemiSens AB, Sweden) was used. The advantage of this method is being the measurement of both heats of absorption and equilibrium solubility data of CO2 at the same time. The measurements were performed for 30 mass % MEA and 5M DEEA solutions as a function of CO2 loading at three...... different temperatures 40, 80 and 120 ºC. The measured 30 mass % MEA and 5M DEEA data were compared with the literature data obtained from different equilibrium cells which validated the use of calorimeters for equilibrium solubility measurements....

  18. Reliability in the utility computing era: Towards reliable Fog computing

    DEFF Research Database (Denmark)

    Madsen, Henrik; Burtschy, Bernard; Albeanu, G.

    2013-01-01

    This paper considers current paradigms in computing and outlines the most important aspects concerning their reliability. The Fog computing paradigm as a non-trivial extension of the Cloud is considered and the reliability of the networks of smart devices are discussed. Combining the reliability...... requirements of grid and cloud paradigms with the reliability requirements of networks of sensor and actuators it follows that designing a reliable Fog computing platform is feasible....

  19. Reliability: How much is it worth? Beyond its estimation or prediction, the (net) present value of reliability

    International Nuclear Information System (INIS)

    Saleh, J.H.; Marais, K.

    2006-01-01

    In this article, we link an engineering concept, reliability, to a financial and managerial concept, net present value, by exploring the impact of a system's reliability on its revenue generation capability. The framework here developed for non-repairable systems quantitatively captures the value of reliability from a financial standpoint. We show that traditional present value calculations of engineering systems do not account for system reliability, thus over-estimate a system's worth and can therefore lead to flawed investment decisions. It is therefore important to involve reliability engineers upfront before investment decisions are made in technical systems. In addition, the analyses here developed help designers identify the optimal level of reliability that maximizes a system's net present value-the financial value reliability provides to the system minus the cost to achieve this level of reliability. Although we recognize that there are numerous considerations driving the specification of an engineering system's reliability, we contend that the financial analysis of reliability here developed should be made available to decision-makers to support in part, or at least be factored into, the system reliability specification

  20. Predictions of flavonoid solubility in ionic liquids by COSMO-RS: experimental verification, structural elucidation, and solvation characterization

    DEFF Research Database (Denmark)

    Guo, Zheng; Lue, Bena-Marie; Thomsen, Kaj

    2007-01-01

    Predictions of the solubility of flavonoids in a large variety of ionic liquids (ILs) with over 1800 available structures were examined based on COSMO-RS computation. The results show that the solubilities of flavonoids are strongly anion-dependent. Experimental measurement of the solubilities...... of esculin and rutin in 12 ILs with varying anions and cations show that predicted and experimental results generally have a good agreement. Based on the sound physical basis of COSMO-RS, the solubility changes of flavonoids were quantitatively associated with solvation interactions and structural...... characteristics of ILs. COSMO-RS derived parameters, i.e. misfit, H-bonding and van der Waals interaction energy, are shown to be capable of characterizing the complicated multiple interactions in the IL system effectively. H-bonding interaction is the most dominant interaction for ILs (followed by misfit and van...

  1. Respiratory carcinogenicity assessment of soluble nickel compounds.

    Science.gov (United States)

    Oller, Adriana R

    2002-10-01

    The many chemical forms of nickel differ in physicochemical properties and biological effects. Health assessments for each main category of nickel species are needed. The carcinogenicity assessment of water-soluble nickel compounds has proven particularly difficult. Epidemiologic evidence indicates an association between inhalation exposures to nickel refinery dust containing soluble nickel compounds and increased risk of respiratory cancers. However, the nature of this association is unclear because of limitations of the exposure data, inconsistent results across cohorts, and the presence of mixed exposures to water-insoluble nickel compounds and other confounders that are known or suspected carcinogens. Moreover, well-conducted animal inhalation studies, where exposures were solely to soluble nickel, failed to demonstrate a carcinogenic potential. Similar negative results were seen in animal oral studies. A model exists that relates respiratory carcinogenic potential to the bioavailability of nickel ion at nuclear sites within respiratory target cells. This model helps reconcile human, animal, and mechanistic data for soluble nickel compounds. For inhalation exposures, the predicted lack of bioavailability of nickel ion at target sites suggests that water-soluble nickel compounds, by themselves, will not be complete human carcinogens. However, if inhaled at concentrations high enough to induce chronic lung inflammation, these compounds may enhance carcinogenic risks associated with inhalation exposure to other substances. Overall, the weight of evidence indicates that inhalation exposure to soluble nickel alone will not cause cancer; moreover, if exposures are kept below levels that cause chronic respiratory toxicity, any possible tumor-enhancing effects (particularly in smokers) would be avoided.

  2. SITE-94. Radionuclide solubilities for SITE-94

    Energy Technology Data Exchange (ETDEWEB)

    Arthur, R.; Apted, M. [QuantiSci, Denver, CO (United States)

    1996-12-01

    In this report, solubility constraints are evaluated on radioelement source-term concentrations supporting the SITE-94 performance assessment. Solubility models are based on heterogeneous-equilibrium, mass- and charge-balance constraints incorporated into the EQ3/6 geochemical software package, which is used to calculate the aqueous speciation behavior and solubilities of U, Th, Pu, Np, Am, Ni, Ra, Se, Sn, Sr, Tc and Zr in site groundwaters and near-field solutions. The chemical evolution of the near field is approximated using EQ3/6 in terms of limiting conditions at equilibrium, or steady state, in three closed systems representing fully saturated bentonite, Fe{sup o} corrosion products of the canister, and spent fuel. The calculations consider both low-temperature (15 deg C) and high-temperature (80 deg C) conditions in the near field, and the existence of either reducing or strongly oxidizing conditions in each of the bentonite, canister, and spent-fuel barriers. Heterogeneities in site characteristics are evaluated through consideration of a range of initial groundwaters and their interactions with engineered barriers. Aqueous speciation models for many radioelements are constrained by thermodynamic data that are estimated with varying degrees of accuracy. An important question, however, is how accurate do these models need to be for purposes of estimating source-term concentrations? For example, it is unrealistic to expect a high degree of accuracy in speciation models if such models predict solubilities that are below the analytical detection limit for a given radioelement. From a practical standpoint, such models are irrelevant if calculated solubilities cannot be tested by direct comparison to experimental data. In the absence of models that are both accurate and relevant for conditions of interest, the detection limit could define a pragmatic upper limit on radioelement solubility 56 refs, 25 tabs, 10 figs

  3. SITE-94. Radionuclide solubilities for SITE-94

    International Nuclear Information System (INIS)

    Arthur, R.; Apted, M.

    1996-12-01

    In this report, solubility constraints are evaluated on radioelement source-term concentrations supporting the SITE-94 performance assessment. Solubility models are based on heterogeneous-equilibrium, mass- and charge-balance constraints incorporated into the EQ3/6 geochemical software package, which is used to calculate the aqueous speciation behavior and solubilities of U, Th, Pu, Np, Am, Ni, Ra, Se, Sn, Sr, Tc and Zr in site groundwaters and near-field solutions. The chemical evolution of the near field is approximated using EQ3/6 in terms of limiting conditions at equilibrium, or steady state, in three closed systems representing fully saturated bentonite, Fe o corrosion products of the canister, and spent fuel. The calculations consider both low-temperature (15 deg C) and high-temperature (80 deg C) conditions in the near field, and the existence of either reducing or strongly oxidizing conditions in each of the bentonite, canister, and spent-fuel barriers. Heterogeneities in site characteristics are evaluated through consideration of a range of initial groundwaters and their interactions with engineered barriers. Aqueous speciation models for many radioelements are constrained by thermodynamic data that are estimated with varying degrees of accuracy. An important question, however, is how accurate do these models need to be for purposes of estimating source-term concentrations? For example, it is unrealistic to expect a high degree of accuracy in speciation models if such models predict solubilities that are below the analytical detection limit for a given radioelement. From a practical standpoint, such models are irrelevant if calculated solubilities cannot be tested by direct comparison to experimental data. In the absence of models that are both accurate and relevant for conditions of interest, the detection limit could define a pragmatic upper limit on radioelement solubility

  4. Methods for Quantitative Creatinine Determination.

    Science.gov (United States)

    Moore, John F; Sharer, J Daniel

    2017-04-06

    Reliable measurement of creatinine is necessary to assess kidney function, and also to quantitate drug levels and diagnostic compounds in urine samples. The most commonly used methods are based on the Jaffe principal of alkaline creatinine-picric acid complex color formation. However, other compounds commonly found in serum and urine may interfere with Jaffe creatinine measurements. Therefore, many laboratories have made modifications to the basic method to remove or account for these interfering substances. This appendix will summarize the basic Jaffe method, as well as a modified, automated version. Also described is a high performance liquid chromatography (HPLC) method that separates creatinine from contaminants prior to direct quantification by UV absorption. Lastly, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is described that uses stable isotope dilution to reliably quantify creatinine in any sample. This last approach has been recommended by experts in the field as a means to standardize all quantitative creatinine methods against an accepted reference. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  5. Hydrogen solubility in austenite of Fe-Ni-Cr alloys

    International Nuclear Information System (INIS)

    Zhirnova, V.V.; Mogutnov, B.M.; Tomilin, I.A.

    1981-01-01

    Hydrogen solubility in Fe-Ni-Cr alloys at 600-1000 deg C is determined. Hydrogen solubility in ternary alloys can not be predicted on the basis of the data on its solubility in binary Fe-Ni, Fe-Cr alloys. Chromium and nickel effect on hydrogen solubility in iron is insignificant in comparison with the effect of these elements on carbon or nitrogen solubility [ru

  6. RTE - Reliability report 2016

    International Nuclear Information System (INIS)

    2017-06-01

    Every year, RTE produces a reliability report for the past year. This document lays out the main factors that affected the electrical power system's operational reliability in 2016 and the initiatives currently under way intended to ensure its reliability in the future. Within a context of the energy transition, changes to the European interconnected network mean that RTE has to adapt on an on-going basis. These changes include the increase in the share of renewables injecting an intermittent power supply into networks, resulting in a need for flexibility, and a diversification in the numbers of stakeholders operating in the energy sector and changes in the ways in which they behave. These changes are dramatically changing the structure of the power system of tomorrow and the way in which it will operate - particularly the way in which voltage and frequency are controlled, as well as the distribution of flows, the power system's stability, the level of reserves needed to ensure supply-demand balance, network studies, assets' operating and control rules, the tools used and the expertise of operators. The results obtained in 2016 are evidence of a globally satisfactory level of reliability for RTE's operations in somewhat demanding circumstances: more complex supply-demand balance management, cross-border schedules at interconnections indicating operation that is closer to its limits and - most noteworthy - having to manage a cold spell just as several nuclear power plants had been shut down. In a drive to keep pace with the changes expected to occur in these circumstances, RTE implemented numerous initiatives to ensure high levels of reliability: - maintaining investment levels of euro 1.5 billion per year; - increasing cross-zonal capacity at borders with our neighbouring countries, thus bolstering the security of our electricity supply; - implementing new mechanisms (demand response, capacity mechanism, interruptibility, etc.); - involvement in tests or projects

  7. A Systematic Study of Molecular Interactions of Anionic Drugs with a Dimethylaminoethyl Methacrylate Copolymer Regarding Solubility Enhancement.

    Science.gov (United States)

    Saal, Wiebke; Ross, Alfred; Wyttenbach, Nicole; Alsenz, Jochem; Kuentz, Martin

    2017-04-03

    The methacrylate-copolymer Eudragit EPO (EPO) has raised interest in solubility enhancement of anionic drugs. Effects on aqueous drug solubility at rather low polymer concentrations are barely known despite their importance upon dissolution and dilution of oral dosage forms. We provide evidence for substantial enhancement (factor 4-230) of aqueous solubility of poorly water-soluble anionic drugs induced by low (0.1-5% (w/w)) concentration of EPO for a panel of seven acidic crystalline drugs. Diffusion data (determined by 1 H nuclear magnetic resonance spectroscopy) indicate that the solubility increasing effect monitored by quantitative ultraperformance liquid chromatography was caused primarily by molecular API polymer interactions in the bulk liquid phase. Residual solid API remained unaltered as tested by X-ray powder diffraction. The solubility enhancement (SE) revealed a significant rank correlation (r Spearman = -0.83) with rDiff API , where SE and rDiff API are defined ratios of solubility and diffusion coefficient in the presence and absence of EPO. SE decreased in the order of indomethacin, mefenamic acid, warfarin, piroxicam, furosemide, bezafibrate, and tolbutamide. The solubilizing effect was attributed to both ionic and hydrophobic interactions between drugs and EPO. The excellent solubilizing properties of EPO are highly promising for pharmaceutical development, and the data set provides first steps toward an understanding of drug-excipient interaction mechanisms.

  8. Hydrogen terminal solubility in Zircaloy-4

    International Nuclear Information System (INIS)

    Vizcaino, Pablo; Banchik, Abrahan D.

    1999-01-01

    Terminal solubility temperature of hydrogen in zirconium and its alloys is an important parameter because hydrides precipitation embrittled these materials making them susceptible to the phenomenon known as retarded hydrogen cracking. This work continues the study presented in the 25 AATN Meeting. Within this framework, a study focused on determining these curves in recrystallized Zircaloy-4, using scanning differential calorimetric technique. Terminal solubility curves for Zircaloy-4 were constructed within a concentration range from 40 to 640 ppm in hydrogen weight and comparisons with results obtained by other authors were made. (author)

  9. Nitrogen solubility in nickel base multicomponent melts

    International Nuclear Information System (INIS)

    Bol'shov, L.A.; Stomakhin, A.Ya.; Sokolov, V.M.; Teterin, V.G.

    1984-01-01

    Applicability of various methods for calculation of nitrogen solubility in high-alloyed nickel base alloys, containing Cr, Fe, W, Mo, Ti, Nb, has been estimated. A possibility is shown to use the formUla, derived for the calculation of nitrogen solubility in iron on the basis of statistical theory for a grid model of solution which does not require limitations for the content of a solvent component. The calculation method has been used for nickel alloys, with the concentration of solvent, iron, being accepted equal to zero, and employing parameters of nitrogen interaction as determined for iron-base alloys

  10. Effect of amides on lithium tetraborate solubility

    Energy Technology Data Exchange (ETDEWEB)

    Tsekhanskij, R S; Skvortsov, V C; Molodkin, A K; Sadetdi-pov, Sh V [Chuvashskij Gosudarstvennyj Pedagogicheskij Inst., Cheboksary (USSR); Universitet Druzhby Narodov, Moscow (USSR))

    1983-03-01

    Using the methods of solubility, densi- and refractometry at 25 deg C, it has been established that the systems lithium tetraborate-formamide (acetamide, dimethyl-formamide)-water are of a simple eutonic type. Amides decrease the salt solubility. Lyotropic effect, as calculated for molar concentrations (-Lsub(M)) relative to the absolute value, increases from formamide to dimethyl-formamide. The sequence is determined by the fact that, when there is one or two hydrophilic methyl groups in amide molecules which are in contact with tetraborate, they decrease the hydration energy of lithium cations.

  11. Effect of amides on sodium tetraborate solubility

    International Nuclear Information System (INIS)

    Tsekhanskij, R.S.; Skvortsov, V.G.; Molodkin, A.K.; Sadetdinov, Sh.V.

    1986-01-01

    Methods of solubility and refractometry at 25 deg C were applied to investigate sodium tetraborate - formamide (dimethylformamide) - water systems. It is stated that they are of simple eutonic type as well as the earlier described sodium tetraborate-acetamide-water system. Amides reduce solubility of the salt. The effect of contact interaction between dissolved substances on salt cation hydration and thus on the value of liotropic amide effect is confirmed. This value is found to be also depend on the number of molecules of coordination water in the initial crystalline hydrate

  12. Effect of amides on lithium tetraborate solubility

    International Nuclear Information System (INIS)

    Tsekhanskij, R.S.; Skvortsov, V.C.; Molodkin, A.K.; Sadetdi- pov, Sh.V.

    1983-01-01

    Using the methods of solubility, densi- and refractometry at 25 deg C, it has been established that the systemS lithium tetraborate-formamide (acetamide, dimethyl-formamide)-water are of a simple eutonic type. Amides decrease the salt solubility. Lyotropic effect, as calculated for molar concentrations (-Lsub(M)) relative to the absolute value, increases from formamide to dimethylformamide. The sequence is determined by the fact that, when there is one or two hydrophilic methyl groups in amide molecules which are in contact with tetraborate, they decrease the hydration energy of lithium cations

  13. Effect of amides on sodium tetraborate solubility

    Energy Technology Data Exchange (ETDEWEB)

    Tsekhanskij, R S; Skvortsov, V G; Molodkin, A K; Sadetdinov, Sh V

    1986-11-01

    Methods of solubility and refractometry at 25 deg C were applied to investigate sodium tetraborate - formamide (dimethylformamide) - water systems. It is stated that they are of simple eutonic type as well as the earlier described sodium tetraborate-acetamide-water system. Amides reduce solubility of the salt. The effect of contact interaction between dissolved substances on salt cation hydration and thus on the value of liotropic amide effect is confirmed. This value is found to be also depend on the number of molecules of coordination water in the initial crystalline hydrate.

  14. Modeling of Salt Solubilities in Mixed Solvents

    DEFF Research Database (Denmark)

    Chiavone-Filho, O.; Rasmussen, Peter

    2000-01-01

    A method to correlate and predict salt solubilities in mixed solvents using a UNIQUAC+Debye-Huckel model is developed. The UNIQUAC equation is applied in a form with temperature-dependent parameters. The Debye-Huckel model is extended to mixed solvents by properly evaluating the dielectric...... constants and the liquid densities of the solvent media. To normalize the activity coefficients, the symmetric convention is adopted. Thermochemical properties of the salt are used to estimate the solubility product. It is shown that the proposed procedure can describe with good accuracy a series of salt...

  15. The contribution of instrumentation and control software to system reliability

    International Nuclear Information System (INIS)

    Fryer, M.O.

    1984-01-01

    Advanced instrumentation and control systems are usually implemented using computers that monitor the instrumentation and issue commands to control elements. The control commands are based on instrument readings and software control logic. The reliability of the total system will be affected by the software design. When comparing software designs, an evaluation of how each design can contribute to the reliability of the system is desirable. Unfortunately, the science of reliability assessment of combined hardware and software systems is in its infancy. Reliability assessment of combined hardware/software systems is often based on over-simplified assumptions about software behavior. A new method of reliability assessment of combined software/hardware systems is presented. The method is based on a procedure called fault tree analysis which determines how component failures can contribute to system failure. Fault tree analysis is a well developed method for reliability assessment of hardware systems and produces quantitative estimates of failure probability based on component failure rates. It is shown how software control logic can be mapped into a fault tree that depicts both software and hardware contributions to system failure. The new method is important because it provides a way for quantitatively evaluating the reliability contribution of software designs. In many applications, this can help guide designers in producing safer and more reliable systems. An application to the nuclear power research industry is discussed

  16. Optimization method for quantitative calculation of clay minerals in soil

    Indian Academy of Sciences (India)

    However, no reliable method for quantitative analysis of clay minerals has been established so far. In this study, an attempt was made to propose an optimization method for the quantitative ... 2. Basic principles. The mineralogical constitution of soil is rather complex. ... K2O, MgO, and TFe as variables for the calculation.

  17. Accelerator reliability workshop

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, L; Duru, Ph; Koch, J M; Revol, J L; Van Vaerenbergh, P; Volpe, A M; Clugnet, K; Dely, A; Goodhew, D

    2002-07-01

    About 80 experts attended this workshop, which brought together all accelerator communities: accelerator driven systems, X-ray sources, medical and industrial accelerators, spallation sources projects (American and European), nuclear physics, etc. With newly proposed accelerator applications such as nuclear waste transmutation, replacement of nuclear power plants and others. Reliability has now become a number one priority for accelerator designers. Every part of an accelerator facility from cryogenic systems to data storage via RF systems are concerned by reliability. This aspect is now taken into account in the design/budget phase, especially for projects whose goal is to reach no more than 10 interruptions per year. This document gathers the slides but not the proceedings of the workshop.

  18. Human Reliability Program Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Landers, John; Rogers, Erin; Gerke, Gretchen

    2014-05-18

    A Human Reliability Program (HRP) is designed to protect national security as well as worker and public safety by continuously evaluating the reliability of those who have access to sensitive materials, facilities, and programs. Some elements of a site HRP include systematic (1) supervisory reviews, (2) medical and psychological assessments, (3) management evaluations, (4) personnel security reviews, and (4) training of HRP staff and critical positions. Over the years of implementing an HRP, the Department of Energy (DOE) has faced various challenges and overcome obstacles. During this 4-day activity, participants will examine programs that mitigate threats to nuclear security and the insider threat to include HRP, Nuclear Security Culture (NSC) Enhancement, and Employee Assistance Programs. The focus will be to develop an understanding of the need for a systematic HRP and to discuss challenges and best practices associated with mitigating the insider threat.

  19. Reliability and construction control

    Directory of Open Access Journals (Sweden)

    Sherif S. AbdelSalam

    2016-06-01

    Full Text Available The goal of this study was to determine the most reliable and efficient combination of design and construction methods required for vibro piles. For a wide range of static and dynamic formulas, the reliability-based resistance factors were calculated using EGYPT database, which houses load test results for 318 piles. The analysis was extended to introduce a construction control factor that determines the variation between the pile nominal capacities calculated using static versus dynamic formulae. From the major outcomes, the lowest coefficient of variation is associated with Davisson’s criterion, and the resistance factors calculated for the AASHTO method are relatively high compared with other methods. Additionally, the CPT-Nottingham and Schmertmann method provided the most economic design. Recommendations related to a pile construction control factor were also presented, and it was found that utilizing the factor can significantly reduce variations between calculated and actual capacities.

  20. Scyllac equipment reliability analysis

    International Nuclear Information System (INIS)

    Gutscher, W.D.; Johnson, K.J.

    1975-01-01

    Most of the failures in Scyllac can be related to crowbar trigger cable faults. A new cable has been designed, procured, and is currently undergoing evaluation. When the new cable has been proven, it will be worked into the system as quickly as possible without causing too much additional down time. The cable-tip problem may not be easy or even desirable to solve. A tightly fastened permanent connection that maximizes contact area would be more reliable than the plug-in type of connection in use now, but it would make system changes and repairs much more difficult. The balance of the failures have such a low occurrence rate that they do not cause much down time and no major effort is underway to eliminate them. Even though Scyllac was built as an experimental system and has many thousands of components, its reliability is very good. Because of this the experiment has been able to progress at a reasonable pace

  1. Improving Power Converter Reliability

    DEFF Research Database (Denmark)

    Ghimire, Pramod; de Vega, Angel Ruiz; Beczkowski, Szymon

    2014-01-01

    of a high-power IGBT module during converter operation, which may play a vital role in improving the reliability of the power converters. The measured voltage is used to estimate the module average junction temperature of the high and low-voltage side of a half-bridge IGBT separately in every fundamental......The real-time junction temperature monitoring of a high-power insulated-gate bipolar transistor (IGBT) module is important to increase the overall reliability of power converters for industrial applications. This article proposes a new method to measure the on-state collector?emitter voltage...... is measured in a wind power converter at a low fundamental frequency. To illustrate more, the test method as well as the performance of the measurement circuit are also presented. This measurement is also useful to indicate failure mechanisms such as bond wire lift-off and solder layer degradation...

  2. Accelerator reliability workshop

    International Nuclear Information System (INIS)

    Hardy, L.; Duru, Ph.; Koch, J.M.; Revol, J.L.; Van Vaerenbergh, P.; Volpe, A.M.; Clugnet, K.; Dely, A.; Goodhew, D.

    2002-01-01

    About 80 experts attended this workshop, which brought together all accelerator communities: accelerator driven systems, X-ray sources, medical and industrial accelerators, spallation sources projects (American and European), nuclear physics, etc. With newly proposed accelerator applications such as nuclear waste transmutation, replacement of nuclear power plants and others. Reliability has now become a number one priority for accelerator designers. Every part of an accelerator facility from cryogenic systems to data storage via RF systems are concerned by reliability. This aspect is now taken into account in the design/budget phase, especially for projects whose goal is to reach no more than 10 interruptions per year. This document gathers the slides but not the proceedings of the workshop

  3. Safety and reliability assessment

    International Nuclear Information System (INIS)

    1979-01-01

    This report contains the papers delivered at the course on safety and reliability assessment held at the CSIR Conference Centre, Scientia, Pretoria. The following topics were discussed: safety standards; licensing; biological effects of radiation; what is a PWR; safety principles in the design of a nuclear reactor; radio-release analysis; quality assurance; the staffing, organisation and training for a nuclear power plant project; event trees, fault trees and probability; Automatic Protective Systems; sources of failure-rate data; interpretation of failure data; synthesis and reliability; quantification of human error in man-machine systems; dispersion of noxious substances through the atmosphere; criticality aspects of enrichment and recovery plants; and risk and hazard analysis. Extensive examples are given as well as case studies

  4. Reliability of Circumplex Axes

    Directory of Open Access Journals (Sweden)

    Micha Strack

    2013-06-01

    Full Text Available We present a confirmatory factor analysis (CFA procedure for computing the reliability of circumplex axes. The tau-equivalent CFA variance decomposition model estimates five variance components: general factor, axes, scale-specificity, block-specificity, and item-specificity. Only the axes variance component is used for reliability estimation. We apply the model to six circumplex types and 13 instruments assessing interpersonal and motivational constructs—Interpersonal Adjective List (IAL, Interpersonal Adjective Scales (revised; IAS-R, Inventory of Interpersonal Problems (IIP, Impact Messages Inventory (IMI, Circumplex Scales of Interpersonal Values (CSIV, Support Action Scale Circumplex (SAS-C, Interaction Problems With Animals (IPI-A, Team Role Circle (TRC, Competing Values Leadership Instrument (CV-LI, Love Styles, Organizational Culture Assessment Instrument (OCAI, Customer Orientation Circle (COC, and System for Multi-Level Observation of Groups (behavioral adjectives; SYMLOG—in 17 German-speaking samples (29 subsamples, grouped by self-report, other report, and metaperception assessments. The general factor accounted for a proportion ranging from 1% to 48% of the item variance, the axes component for 2% to 30%; and scale specificity for 1% to 28%, respectively. Reliability estimates varied considerably from .13 to .92. An application of the Nunnally and Bernstein formula proposed by Markey, Markey, and Tinsley overestimated axes reliabilities in cases of large-scale specificities but otherwise works effectively. Contemporary circumplex evaluations such as Tracey’s RANDALL are sensitive to the ratio of the axes and scale-specificity components. In contrast, the proposed model isolates both components.

  5. The cost of reliability

    International Nuclear Information System (INIS)

    Ilic, M.

    1998-01-01

    In this article the restructuring process under way in the US power industry is being revisited from the point of view of transmission system provision and reliability was rolled into the average cost of electricity to all, it is not so obvious how is this cost managed in the new industry. A new MIT approach to transmission pricing is here suggested as a possible solution [it

  6. Considerations on the elements of quantifying human reliability

    International Nuclear Information System (INIS)

    Straeter, Oliver

    2004-01-01

    This paper attempts to provide a contribution for the discussion of what the term 'data' means and how the qualitative perspective can be linked with the quantitative one. It will argue that the terms 'quantitative data' and 'qualitative data' are not distinct but a continuum that spans over the entire spectrum of the expertise that has to be involved in the HRA process. It elaborates the rational behind any human reliability quantification figure and suggests a scientific way forward to better data for human reliability assessment

  7. Software reliability studies

    Science.gov (United States)

    Hoppa, Mary Ann; Wilson, Larry W.

    1994-01-01

    There are many software reliability models which try to predict future performance of software based on data generated by the debugging process. Our research has shown that by improving the quality of the data one can greatly improve the predictions. We are working on methodologies which control some of the randomness inherent in the standard data generation processes in order to improve the accuracy of predictions. Our contribution is twofold in that we describe an experimental methodology using a data structure called the debugging graph and apply this methodology to assess the robustness of existing models. The debugging graph is used to analyze the effects of various fault recovery orders on the predictive accuracy of several well-known software reliability algorithms. We found that, along a particular debugging path in the graph, the predictive performance of different models can vary greatly. Similarly, just because a model 'fits' a given path's data well does not guarantee that the model would perform well on a different path. Further we observed bug interactions and noted their potential effects on the predictive process. We saw that not only do different faults fail at different rates, but that those rates can be affected by the particular debugging stage at which the rates are evaluated. Based on our experiment, we conjecture that the accuracy of a reliability prediction is affected by the fault recovery order as well as by fault interaction.

  8. Investment in new product reliability

    International Nuclear Information System (INIS)

    Murthy, D.N.P.; Rausand, M.; Virtanen, S.

    2009-01-01

    Product reliability is of great importance to both manufacturers and customers. Building reliability into a new product is costly, but the consequences of inadequate product reliability can be costlier. This implies that manufacturers need to decide on the optimal investment in new product reliability by achieving a suitable trade-off between the two costs. This paper develops a framework and proposes an approach to help manufacturers decide on the investment in new product reliability.

  9. Quantitative investment analysis

    CERN Document Server

    DeFusco, Richard

    2007-01-01

    In the "Second Edition" of "Quantitative Investment Analysis," financial experts Richard DeFusco, Dennis McLeavey, Jerald Pinto, and David Runkle outline the tools and techniques needed to understand and apply quantitative methods to today's investment process.

  10. Rigour in quantitative research.

    Science.gov (United States)

    Claydon, Leica Sarah

    2015-07-22

    This article which forms part of the research series addresses scientific rigour in quantitative research. It explores the basis and use of quantitative research and the nature of scientific rigour. It examines how the reader may determine whether quantitative research results are accurate, the questions that should be asked to determine accuracy and the checklists that may be used in this process. Quantitative research has advantages in nursing, since it can provide numerical data to help answer questions encountered in everyday practice.

  11. Revisiting Hansen Solubility Parameters by Including Thermodynamics

    NARCIS (Netherlands)

    Louwerse, Manuel J; Fernández-Maldonado, Ana María; Rousseau, Simon; Moreau-Masselon, Chloe; Roux, Bernard; Rothenberg, Gadi

    2017-01-01

    The Hansen solubility parameter approach is revisited by implementing the thermodynamics of dissolution and mixing. Hansen's pragmatic approach has earned its spurs in predicting solvents for polymer solutions, but for molecular solutes improvements are needed. By going into the details of entropy

  12. Solubility of hydrogen in delta iron

    International Nuclear Information System (INIS)

    Shapovalov, V.I.; Trofimenko, V.V.

    1979-01-01

    The solubility of hydrogen in iron (less than 0.002 % impurities) at temperatures of 800-1510 deg C and a pressure of 100 atm was measured. The heat of solution of hydrogen in delta-Fe, equal to 73 kJ/g-atom, is by far greater than the corresponding values for α- and γ-Fe

  13. Solubility of ethylene in methyl propionate

    NARCIS (Netherlands)

    Shariati - Sarabi, A.; Florusse, L.J.; Peters, C.J.

    2015-01-01

    In this work, the solubility of ethylene in methyl propionate was measured within a temperature range of 283.5–464.8 K and pressures up to 10.7 MPa. Experiments were carried out using the Cailletet apparatus, which uses a synthetic method for the experiments. The critical points of several isopleths

  14. Radiculography with water-soluble contraste medium

    International Nuclear Information System (INIS)

    Araujo Pinheiro, R.S. de

    1987-01-01

    The etiologic diagnosis of the lumbar pain is discussed. The radiculography with water-soluble contrast medium is used and 250 cases are studied. Some practical criteria of indication executation and interpretation of the examination are reported. (M.A.C.) [pt

  15. Solubility of heavy metals added to MSW

    International Nuclear Information System (INIS)

    Lo, H.M.; Lin, K.C.; Liu, M.H.; Pai, T.Z.; Lin, C.Y.; Liu, W.F.; Fang, G.C.; Lu, C.; Chiang, C.F.; Wang, S.C.; Chen, P.H.; Chen, J.K.; Chiu, H.Y.; Wu, K.C.

    2009-01-01

    This paper aims to investigate the six heavy metal levels (Cd, Cr, Cu, Pb, Ni and Zn) in municipal solid waste (MSW) at different pHs. It intends to provide the baseline information of metals solubility in MSW co-disposed or co-digested with MSW incinerator ashes in landfill or anaerobic bioreactors or heavy metals contaminated in anaerobic digesters. One milliliter (equal to 1 mg) of each metal was added to the 100 ml MSW and the batch reactor test was carried out. The results showed that higher HNO 3 and NaOH were consumed at extreme pH of 1 and 13 compared to those from pH 2 to 11 due to the comparably higher buffer capacity. Pb was found to have the least soluble level, highest metal adsorption (%) and highest partitioning K d (l g -1 ) between pH 3 and 12. In contrast, Ni showed the highest soluble level, lowest metal adsorption (%) and lowest K d (l g -1 ) between pH 4 and 12. Except Ni and Cr, other four metals seemed to show the amphibious properties as comparative higher solubility was found in the acidic and basic conditions

  16. Solubility of heavy metals added to MSW

    Energy Technology Data Exchange (ETDEWEB)

    Lo, H.M. [Department of Environmental Engineering and Management, Chaoyang University of Technology, 168 Gifong E. Road, Wufong, Taichung County 41349, Taiwan (China)], E-mail: hmlo@cyut.edu.tw; Lin, K.C. [Department of Occupational Safety and Health, Chung Shan Medical University, 110, Sec. 1, Jiangguo N. Rd., Taichung 402, Taiwan (China); Liu, M.H.; Pai, T.Z. [Department of Environmental Engineering and Management, Chaoyang University of Technology, 168 Gifong E. Road, Wufong, Taichung County 41349, Taiwan (China); Lin, C.Y. [Department of Soil and Water Conservation, Chung Hsing University, 250 Kuokuang Road, Taichung 402, Taiwan (China); Liu, W.F. [Department of Electronical Engineering, Feng Chia University, 100 Wenhwa Road, Taichung 407, Taiwan (China); Fang, G.C. [Department of Environmental Engineering, Hungkuang University, 34 Chung-Chie Road, Sha Lu, Taichung 433, Taiwan (China); Lu, C. [Department of Environmental Engineering, Chung Hsing University, 250 Kuokuang Road, Taichung 402, Taiwan (China); Chiang, C.F. [Department of Health Risk Management, China Medical University, No. 91 Hsueh-Shih Road, Taichung 40402, Taiwan (China); Wang, S.C.; Chen, P.H.; Chen, J.K.; Chiu, H.Y.; Wu, K.C. [Department of Environmental Engineering and Management, Chaoyang University of Technology, 168 Gifong E. Road, Wufong, Taichung County 41349, Taiwan (China)

    2009-01-15

    This paper aims to investigate the six heavy metal levels (Cd, Cr, Cu, Pb, Ni and Zn) in municipal solid waste (MSW) at different pHs. It intends to provide the baseline information of metals solubility in MSW co-disposed or co-digested with MSW incinerator ashes in landfill or anaerobic bioreactors or heavy metals contaminated in anaerobic digesters. One milliliter (equal to 1 mg) of each metal was added to the 100 ml MSW and the batch reactor test was carried out. The results showed that higher HNO{sub 3} and NaOH were consumed at extreme pH of 1 and 13 compared to those from pH 2 to 11 due to the comparably higher buffer capacity. Pb was found to have the least soluble level, highest metal adsorption (%) and highest partitioning K{sub d} (l g{sup -1}) between pH 3 and 12. In contrast, Ni showed the highest soluble level, lowest metal adsorption (%) and lowest K{sub d} (l g{sup -1}) between pH 4 and 12. Except Ni and Cr, other four metals seemed to show the amphibious properties as comparative higher solubility was found in the acidic and basic conditions.

  17. Anomalous Solubility Behavior of Several Acidic Drugs

    Directory of Open Access Journals (Sweden)

    Alex Avdeef

    2014-04-01

    Full Text Available The “anomalous solubility behavior at higher pH values” of several acidic drugs originally studied by Higuchi et al. in 1953 [1], but hitherto not fully rationalized, has been re-analyzed using a novel solubility-pH analysis computer program, pDISOL-XTM. The program internally derives implicit solubility equations, given a set of proposed equilibria and constants (iteratively refined by weighted nonlinear regression, and does not require explicit Henderson-Hasselbalch equations. The re-analyzed original barbital, phenobarbital, oxytetracycline, and sulfathiazole solubility-pH data of Higuchi et al. is consistent with the presence of dimers in saturated solutions. In the case of barbital, phenobarbital and sulfathiazole, anionic dimers, reaching peak concentrations near pH 8. However, oxytetracycline indicated a pronounced tendency to form a cationic dimer, peaking near pH 2. Under the conditions of the original study, only barbital indicated a slight tendency to form a salt precipitate at pH > 6.8, with a highly unusual stoichiometry (consistent with a slope of 0.55 in the log S – pH plot: K+ + A2H- + 3HA D KA5H4(s. Thus the “anomaly” in the Higuchi data can be rationalized by invoking specific aggregated species.

  18. Changes in protein solubility, fermentative capacity, viscoelasticity ...

    African Journals Online (AJOL)

    Frozen dough should be stored for fewer than 21 days; time in which the loaf volume of bread made from frozen dough was approximately 40.84% smaller than that of fresh bread dough formulation. Keywords: French type bread, frozen dough, protein solubility, baking quality, viscoelasticity. African Journal of Biotechnology ...

  19. Solubility of Tc(IV) oxides

    International Nuclear Information System (INIS)

    Liu, D.J.; Fan, X.H.

    2005-01-01

    Full text of publication follows: The deep geological disposal of the high level radioactive wastes is expected to be a safer disposal method in most countries. The long-lived fission product 99 Tc is present in large quantities in nuclear wastes and its chemical behavior in aqueous solution is of considerable interest. Under the reducing conditions, expected to exist in a deep geological repository, it is generally predicted that technetium will be present as TcO 2 .nH 2 O. The solubility of Tc(IV) is used as a source term in performance assessment of radioactive waste repository. Technetium oxide was prepared by reduction of a technetate solution with Sn 2+ . The solubility of Tc(IV) oxide has been determined in simulated groundwater and re-distilled water under aerobic and anaerobic conditions. The effects of pH and CO 3 2- concentration of solution on solubility of Tc(IV) oxide were studied. The concentration of total technetium and Tc(IV) species in the solutions were periodically determined by separating the oxidized and reduced technetium species using a solvent extraction procedure and counting the beta activity of the 99 Tc with a liquid scintillation counter. The experimental results show that the rate of oxidation of Tc(IV) in simulated groundwater and re-distilled water is about (1.49∼1.86) x 10 -9 mol/(L.d) under aerobic conditions, but Tc(IV) in simulated groundwater and re-distilled water is not oxidized under anaerobic conditions. Under aerobic or anaerobic conditions the solubility of Tc(IV) oxide in simulated groundwater and re-distilled water is equal on the whole after centrifugation or ultrafiltration. The solubility of Tc(IV) oxide decreases with the increase of pH at pH 10 and is pH independent in the range 2 -8 to 10 -9 mol/L at 2 3 2- concentration. These data could be used to estimate the Tc(IV) solubility for cases where solubility limits transport of technetium in reducing environments of high-level waste repositories. (authors)

  20. Quantitation: clinical applications

    International Nuclear Information System (INIS)

    Britton, K.E.

    1982-01-01

    Single photon emission tomography may be used quantitatively if its limitations are recognized and quantitation is made in relation to some reference area on the image. Relative quantitation is discussed in outline in relation to the liver, brain and pituitary, thyroid, adrenals, and heart. (U.K.)

  1. Reprodutibilidade de questionário semiquantitativo de freqüência alimentar elaborado para adolescentes da Região Metropolitana do Rio de Janeiro, Brasil Reliability of a semi-quantitative food frequency questionnaire designed for adolescents from the Rio de Janeiro Metropolitan Area, Brazil

    Directory of Open Access Journals (Sweden)

    Marina Campos Araújo

    2008-12-01

    Full Text Available A reprodutibilidade de questionário semiquantitativo de freqüência alimentar (QSFA para adolescentes do Rio de Janeiro, Brasil, foi analisada entre 108 adolescentes. O intervalo médio entre as duas aplicações do QSFA foi de vinte dias. A lista de alimentos e as porções de referência do QSFA basearam-se em dados de registros alimentares de 430 adolescentes. Estimaram-se coeficientes de correlação intraclasse para itens alimentares e coeficientes de correlação de Pearson para nutrientes. A concordância da classificação em quartis para nutrientes foi estimada pelo kappa ponderado. O método de Bland-Altman avaliou a concordância para nutrientes. Apresentaram-se dados brutos e ajustados pela energia. Para os itens alimentares, a média dos coeficientes de correlação intraclasse foi 0,54. Para dados ajustados, a concordância para o mesmo quartil e quartis adjacentes variou de 72% a 86%. Segundo o método de Bland-Altman, a concordância média variou de 77% a 104% e foram independentes da magnitude do consumo, exceto para vitamina A. Os coeficientes de correlação de Pearson variaram de 0,40 a 0,61. O QSFA demonstrou confiabilidade aceitável para as estimativas de alimentos e nutrientes de adolescentes da área considerada.A test-retest study was carried out to assess the reproducibility of a semi-quantitative food frequency questionnaire (SFFQ designed for adolescents. The study group included 108 individuals. The mean interval between the two interviews was 20 days. Three days of food records from 430 adolescents were used to define the items and portions in the SFFQ. Intraclass correlation coefficients (ICC were estimated to assess the agreement in food item reports. The agreement for energy and nutrient intake was assessed by Pearson's correlation coefficients, weighted kappa (agreement in quartile classification, and the Bland-Altman method. Data for nutrients were adjusted according to energy intake. Mean ICC was 0.54. The

  2. Scoring function to predict solubility mutagenesis

    Directory of Open Access Journals (Sweden)

    Deutsch Christopher

    2010-10-01

    Full Text Available Abstract Background Mutagenesis is commonly used to engineer proteins with desirable properties not present in the wild type (WT protein, such as increased or decreased stability, reactivity, or solubility. Experimentalists often have to choose a small subset of mutations from a large number of candidates to obtain the desired change, and computational techniques are invaluable to make the choices. While several such methods have been proposed to predict stability and reactivity mutagenesis, solubility has not received much attention. Results We use concepts from computational geometry to define a three body scoring function that predicts the change in protein solubility due to mutations. The scoring function captures both sequence and structure information. By exploring the literature, we have assembled a substantial database of 137 single- and multiple-point solubility mutations. Our database is the largest such collection with structural information known so far. We optimize the scoring function using linear programming (LP methods to derive its weights based on training. Starting with default values of 1, we find weights in the range [0,2] so that predictions of increase or decrease in solubility are optimized. We compare the LP method to the standard machine learning techniques of support vector machines (SVM and the Lasso. Using statistics for leave-one-out (LOO, 10-fold, and 3-fold cross validations (CV for training and prediction, we demonstrate that the LP method performs the best overall. For the LOOCV, the LP method has an overall accuracy of 81%. Availability Executables of programs, tables of weights, and datasets of mutants are available from the following web page: http://www.wsu.edu/~kbala/OptSolMut.html.

  3. Molybdenum solubility in aluminium nitrate solutions

    Energy Technology Data Exchange (ETDEWEB)

    Heres, X.; Sans, D.; Bertrand, M.; Eysseric, C. [CEA, Centre de Marcoule, Nuclear Energy Division, DRCP, BP 17171, 30207 Bagnols-sur-Ceze Cedex (France); Brackx, E.; Domenger, R.; Excoffier, E. [CEA, Centre de Marcoule, Nuclear Energy Division, DTEC, BP 17171, 30207 Bagnols-sur-Ceze Cedex (France); Valery, J.F. [AREVA-NC, DOR/RDP, Paris - La Defense (France)

    2016-07-01

    For over 60 years, research reactors (RR or RTR for research testing reactors) have been used as neutron sources for research, radioisotope production ({sup 99}Mo/{sup 99m}Tc), nuclear medicine, materials characterization, etc... Currently, over 240 of these reactors are in operation in 56 countries. They are simpler than power reactors and operate at lower temperature (cooled to below 100 C. degrees). The fuel assemblies are typically plates or cylinders of uranium alloy and aluminium (U-Al) coated with pure aluminium. These fuels can be processed in AREVA La Hague plant after batch dissolution in concentrated nitric acid and mixing with UOX fuel streams. The aim of this study is to accurately measure the solubility of molybdenum in nitric acid solution containing high concentrations of aluminium. The higher the molybdenum solubility is, the more flexible reprocessing operations are, especially when the spent fuels contain high amounts of molybdenum. To be most representative of the dissolution process, uranium-molybdenum alloy and molybdenum metal powder were dissolved in solutions of aluminium nitrate at the nominal dissolution temperature. The experiments showed complete dissolution of metallic elements after 30 minutes long stirring, even if molybdenum metal was added in excess. After an induction period, a slow precipitation of molybdic acid occurs for about 15 hours. The data obtained show the molybdenum solubility decreases with increasing aluminium concentration. The solubility law follows an exponential relation around 40 g/L of aluminium with a high determination coefficient. Molybdenum solubility is not impacted by the presence of gadolinium, or by an increasing concentration of uranium. (authors)

  4. System evaluations by means of reliability analyses

    International Nuclear Information System (INIS)

    Breiling, G.

    1976-01-01

    The objective of this study is to show which analysis requirements are associated with the claim that a reliability analysis, as practised at present, can provide a quantitative risk assessment in absolute terms. The question arises of whether this claim can be substantiated without direct access to the specialist technical departments of a manufacturer and to the multifarious detail information available in these departments. The individual problems arising in the course of such an analysis are discussed on the example of a reliability analysis of a core flooding system. The questions discussed relate to analysis organisation, sequence analysis, fault-tree analysis, and the treatment of operational processes superimposed on the failure and repair processes. (orig.) [de

  5. Reliability assessment using Bayesian networks. Case study on quantative reliability estimation of a software-based motor protection relay

    International Nuclear Information System (INIS)

    Helminen, A.; Pulkkinen, U.

    2003-06-01

    In this report a quantitative reliability assessment of motor protection relay SPAM 150 C has been carried out. The assessment focuses to the methodological analysis of the quantitative reliability assessment using the software-based motor protection relay as a case study. The assessment method is based on Bayesian networks and tries to take the full advantage of the previous work done in a project called Programmable Automation System Safety Integrity assessment (PASSI). From the results and experiences achieved during the work it is justified to claim that the assessment method presented in the work enables a flexible use of qualitative and quantitative elements of reliability related evidence in a single reliability assessment. At the same time the assessment method is a concurrent way of reasoning one's beliefs and references about the reliability of the system. Full advantage of the assessment method is taken when using the method as a way to cultivate the information related to the reliability of software-based systems. The method can also be used as a communicational instrument in a licensing process of software-based systems. (orig.)

  6. Methodology for reliability based condition assessment

    International Nuclear Information System (INIS)

    Mori, Y.; Ellingwood, B.

    1993-08-01

    Structures in nuclear power plants may be exposed to aggressive environmental effects that cause their strength to decrease over an extended period of service. A major concern in evaluating the continued service for such structures is to ensure that in their current condition they are able to withstand future extreme load events during the intended service life with a level of reliability sufficient for public safety. This report describes a methodology to facilitate quantitative assessments of current and future structural reliability and performance of structures in nuclear power plants. This methodology takes into account the nature of past and future loads, and randomness in strength and in degradation resulting from environmental factors. An adaptive Monte Carlo simulation procedure is used to evaluate time-dependent system reliability. The time-dependent reliability is sensitive to the time-varying load characteristics and to the choice of initial strength and strength degradation models but not to correlation in component strengths within a system. Inspection/maintenance strategies are identified that minimize the expected future costs of keeping the failure probability of a structure at or below an established target failure probability during its anticipated service period

  7. Nuclear performance and reliability

    International Nuclear Information System (INIS)

    Rothwell, G.

    1993-01-01

    If fewer forced outages are a sign of improved safety, nuclear power plants have become safer and more productive. There has been a significant improvement in nuclear power plant performance, due largely to a decline in the forced outage rate and a dramatic drop in the average number of forced outages per fuel cycle. If fewer forced outages are a sign of improved safety, nuclear power plants have become safer and more productive over time. To encourage further increases in performance, regulatory incentive schemes should reward reactor operators for improved reliability and safety, as well as for improved performance

  8. [How Reliable is Neuronavigation?].

    Science.gov (United States)

    Stieglitz, Lennart Henning

    2016-02-17

    Neuronavigation plays a central role in modern neurosurgery. It allows visualizing instruments and three-dimensional image data intraoperatively and supports spatial orientation. Thus it allows to reduce surgical risks and speed up complex surgical procedures. The growing availability and importance of neuronavigation makes clear how relevant it is to know about its reliability and accuracy. Different factors may influence the accuracy during the surgery unnoticed, misleading the surgeon. Besides the best possible optimization of the systems themselves, a good knowledge about its weaknesses is mandatory for every neurosurgeon.

  9. The value of reliability

    DEFF Research Database (Denmark)

    Fosgerau, Mogens; Karlström, Anders

    2010-01-01

    We derive the value of reliability in the scheduling of an activity of random duration, such as travel under congested conditions. Using a simple formulation of scheduling utility, we show that the maximal expected utility is linear in the mean and standard deviation of trip duration, regardless...... of the form of the standardised distribution of trip durations. This insight provides a unification of the scheduling model and models that include the standard deviation of trip duration directly as an argument in the cost or utility function. The results generalise approximately to the case where the mean...

  10. Determination of radionuclide solubility limits to be used in SR 97. Uncertainties associated to calculated solubilities

    Energy Technology Data Exchange (ETDEWEB)

    Bruno, J.; Cera, E.; Duro, L.; Jordana, S. [QuantiSci S.L., Barcelona (Spain); Pablo, J. de [DEQ-UPC, Barcelona (Spain); Savage, D. [QuantiSci Ltd., Henley-on-Thames (United Kingdom)

    1997-12-01

    The thermochemical behaviour of 24 critical radionuclides for the forthcoming SR97 PA exercise is discussed. The available databases are reviewed and updated with new data and an extended database for aqueous and solid species of the radionuclides of interest is proposed. We have calculated solubility limits for the radionuclides of interest under different groundwater compositions. A sensitivity analysis of the calculated solubilities with the composition of the groundwater is presented. Besides selecting the most likely solubility limiting phases, in this work we have used coprecipitation approaches in order to calculate more realistic solubility limits for minor radionuclides, such as Ra, Am and Cm. The comparison between the calculated solubilities and the concentrations measured in relevant natural systems (NA) and in spent fuel leaching experiments helps to assess the validity of the methodology used and to derive source term concentrations for the radionuclides studied. The uncertainties associated to the solubilities of the main radionuclides involved in the spent nuclear fuel have also been discussed in this work. The variability of the groundwater chemistry; redox conditions and temperature of the system have been considered the main factors affecting the solubilities. In this case, a sensitivity analysis has been performed in order to study solubility changes as a function of these parameters. The uncertainties have been calculated by including the values found in a major extent in typical granitic groundwaters. The results obtained from this analysis indicate that there are some radionuclides which are not affected by these parameters, i.e. Ag, Cm, Ho, Nb, Ni, Np, Pu, Se, Sm, Sn, Sr, Tc and U

  11. Solubility behavior and biopharmaceutical classification of novel high-solubility ciprofloxacin and norfloxacin pharmaceutical derivatives.

    Science.gov (United States)

    Breda, Susana A; Jimenez-Kairuz, Alvaro F; Manzo, Ruben H; Olivera, María E

    2009-04-17

    The hydrochlorides of the 1:3 aluminum:norfloxacin and aluminum:ciprofloxacin complexes were characterized according to the Biopharmaceutics Classification System (BCS) premises in comparison with their parent compounds. The pH-solubility profiles of the complexes were experimentally determined at 25 and 37 degrees C in the range of pH 1-8 and compared to that of uncomplexed norfloxacin and ciprofloxacin. Both complexes are clearly more soluble than the antibiotics themselves, even at the lowest solubility pHs. The increase in solubility was ascribed to the species controlling solubility, which were analyzed in the solid phases at equilibrium at selected pHs. Additionally, permeability was set as low, based on data reported in the scientific literature regarding oral bioavailability, intestinal and cell cultures permeabilities and also considering the influence of stoichiometric amounts of aluminum. The complexes fulfill the BCS criterion to be classified as class 3 compounds (high solubility/low permeability). Instead, the active pharmaceutical ingredients (APIs) currently used in solid dosage forms, norfloxacin and ciprofloxacin hydrochloride, proved to be BCS class 4 (low solubility/low permeability). The solubility improvement turns the complexes as potential biowaiver candidates from the scientific point of view and may be a good way for developing more dose-efficient formulations. An immediate release tablet showing very rapid dissolution was obtained. Its dissolution profile was compared to that of the commercial ciprofloxacin hydrochloride tablets allowing to dissolution of the complete dose at a critical pH such as 6.8.

  12. Effect of Cyclodextrin Complexation on the Aqueous Solubility and Solubility/Dose Ratio of Praziquantel

    OpenAIRE

    Maragos, Stratos; Archontaki, Helen; Macheras, Panos; Valsami, Georgia

    2009-01-01

    Praziquantel (PZQ), the primary drug of choice in the treatment of schistosomiasis, is a highly lipophilic drug that possesses high permeability and low aqueous solubility and is, therefore, classified as a Class II drug according to the Biopharmaceutics Classification System (BCS). In this work, β-cyclodextrin (β-CD) and hydroxypropyl-β-cyclodextrin (HP-β-CD) were used in order to determine whether increasing the aqueous solubility of a drug by complexation with CDs, a BCS-Class II compound ...

  13. Interactive reliability assessment using an integrated reliability data bank

    International Nuclear Information System (INIS)

    Allan, R.N.; Whitehead, A.M.

    1986-01-01

    The logical structure, techniques and practical application of a computer-aided technique based on a microcomputer using floppy disc Random Access Files is described. This interactive computational technique is efficient if the reliability prediction program is coupled directly to a relevant source of data to create an integrated reliability assessment/reliability data bank system. (DG)

  14. Load Control System Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Trudnowski, Daniel [Montana Tech of the Univ. of Montana, Butte, MT (United States)

    2015-04-03

    This report summarizes the results of the Load Control System Reliability project (DOE Award DE-FC26-06NT42750). The original grant was awarded to Montana Tech April 2006. Follow-on DOE awards and expansions to the project scope occurred August 2007, January 2009, April 2011, and April 2013. In addition to the DOE monies, the project also consisted of matching funds from the states of Montana and Wyoming. Project participants included Montana Tech; the University of Wyoming; Montana State University; NorthWestern Energy, Inc., and MSE. Research focused on two areas: real-time power-system load control methodologies; and, power-system measurement-based stability-assessment operation and control tools. The majority of effort was focused on area 2. Results from the research includes: development of fundamental power-system dynamic concepts, control schemes, and signal-processing algorithms; many papers (including two prize papers) in leading journals and conferences and leadership of IEEE activities; one patent; participation in major actual-system testing in the western North American power system; prototype power-system operation and control software installed and tested at three major North American control centers; and, the incubation of a new commercial-grade operation and control software tool. Work under this grant certainly supported the DOE-OE goals in the area of “Real Time Grid Reliability Management.”

  15. Microprocessor hardware reliability

    Energy Technology Data Exchange (ETDEWEB)

    Wright, R I

    1982-01-01

    Microprocessor-based technology has had an impact in nearly every area of industrial electronics and many applications have important safety implications. Microprocessors are being used for the monitoring and control of hazardous processes in the chemical, oil and power generation industries, for the control and instrumentation of aircraft and other transport systems and for the control of industrial machinery. Even in the field of nuclear reactor protection, where designers are particularly conservative, microprocessors are used to implement certain safety functions and may play increasingly important roles in protection systems in the future. Where microprocessors are simply replacing conventional hard-wired control and instrumentation systems no new hazards are created by their use. In the field of robotics, however, the microprocessor has opened up a totally new technology and with it has created possible new and as yet unknown hazards. The paper discusses some of the design and manufacturing techniques which may be used to enhance the reliability of microprocessor based systems and examines the available reliability data on lsi/vlsi microcircuits. 12 references.

  16. Supply chain reliability modelling

    Directory of Open Access Journals (Sweden)

    Eugen Zaitsev

    2012-03-01

    Full Text Available Background: Today it is virtually impossible to operate alone on the international level in the logistics business. This promotes the establishment and development of new integrated business entities - logistic operators. However, such cooperation within a supply chain creates also many problems related to the supply chain reliability as well as the optimization of the supplies planning. The aim of this paper was to develop and formulate the mathematical model and algorithms to find the optimum plan of supplies by using economic criterion and the model for the probability evaluating of non-failure operation of supply chain. Methods: The mathematical model and algorithms to find the optimum plan of supplies were developed and formulated by using economic criterion and the model for the probability evaluating of non-failure operation of supply chain. Results and conclusions: The problem of ensuring failure-free performance of goods supply channel analyzed in the paper is characteristic of distributed network systems that make active use of business process outsourcing technologies. The complex planning problem occurring in such systems that requires taking into account the consumer's requirements for failure-free performance in terms of supply volumes and correctness can be reduced to a relatively simple linear programming problem through logical analysis of the structures. The sequence of the operations, which should be taken into account during the process of the supply planning with the supplier's functional reliability, was presented.

  17. Optimization of single-walled carbon nanotube solubility by noncovalent PEGylation using experimental design methods

    Directory of Open Access Journals (Sweden)

    Hadidi N

    2011-04-01

    Full Text Available Naghmeh Hadidi1, Farzad Kobarfard2, Nastaran Nafissi-Varcheh3, Reza Aboofazeli11Department of Pharmaceutics, 2Department of Pharmaceutical Chemistry, 3Department of Pharmaceutical Biotechnology, School of Pharmacy, Shaheed Beheshti University of Medical Sciences, Tehran, IranAbstract: In this study, noncovalent functionalization of single-walled carbon nanotubes (SWCNTs with phospholipid-polyethylene glycols (Pl-PEGs was performed to improve the solubility of SWCNTs in aqueous solution. Two kinds of PEG derivatives, ie, Pl-PEG 2000 and Pl-PEG 5000, were used for the PEGylation process. An experimental design technique (D-optimal design and second-order polynomial equations was applied to investigate the effect of variables on PEGylation and the solubility of SWCNTs. The type of PEG derivative was selected as a qualitative parameter, and the PEG/SWCNT weight ratio and sonication time were applied as quantitative variables for the experimental design. Optimization was performed for two responses, aqueous solubility and loading efficiency. The grafting of PEG to the carbon nanostructure was determined by thermogravimetric analysis, Raman spectroscopy, and scanning electron microscopy. Aqueous solubility and loading efficiency were determined by ultraviolet-visible spectrophotometry and measurement of free amine groups, respectively. Results showed that Pl-PEGs were grafted onto SWCNTs. Aqueous solubility of 0.84 mg/mL and loading efficiency of nearly 98% were achieved for the prepared Pl-PEG 5000-SWCNT conjugates. Evaluation of functionalized SWCNTs showed that our noncovalent functionalization protocol could considerably increase aqueous solubility, which is an essential criterion in the design of a carbon nanotube-based drug delivery system and its biodistribution.Keywords: phospholipid-PEG, D-optimal design, loading efficiency, Raman spectroscopy, scanning electron microscopy, theromogravimetric analysis, carbon nanotubes

  18. Novel electrosprayed nanospherules for enhanced aqueous solubility and oral bioavailability of poorly water-soluble fenofibrate.

    Science.gov (United States)

    Yousaf, Abid Mehmood; Mustapha, Omer; Kim, Dong Wuk; Kim, Dong Shik; Kim, Kyeong Soo; Jin, Sung Giu; Yong, Chul Soon; Youn, Yu Seok; Oh, Yu-Kyoung; Kim, Jong Oh; Choi, Han-Gon

    2016-01-01

    The purpose of the present research was to develop a novel electrosprayed nanospherule providing the most optimized aqueous solubility and oral bioavailability for poorly water-soluble fenofibrate. Numerous fenofibrate-loaded electrosprayed nanospherules were prepared with polyvinylpyrrolidone (PVP) and Labrafil(®) M 2125 as carriers using the electrospray technique, and the effect of the carriers on drug solubility and solvation was assessed. The solid state characterization of an optimized formulation was conducted by scanning electron microscopy, powder X-ray diffraction, differential scanning calorimetry, and Fourier transform infrared spectroscopic analyses. Oral bioavailability in rats was also evaluated for the formulation of an optimized nanospherule in comparison with free drug and a conventional fenofibrate-loaded solid dispersion. All of the electrosprayed nanospherule formulations had remarkably enhanced aqueous solubility and dissolution compared with free drug. Moreover, Labrafil M 2125, a surfactant, had a positive influence on the solubility and dissolution of the drug in the electrosprayed nanospherule. Increases were observed as the PVP/drug ratio increased to 4:1, but higher ratios gave no significant increases. In particular, an electrosprayed nanospherule composed of fenofibrate, PVP, and Labrafil M 2125 at the weight ratio of 1:4:0.5 resulted in a particle size of water-soluble fenofibrate.

  19. Transit ridership, reliability, and retention.

    Science.gov (United States)

    2008-10-01

    This project explores two major components that affect transit ridership: travel time reliability and rider : retention. It has been recognized that transit travel time reliability may have a significant impact on : attractiveness of transit to many ...

  20. Travel reliability inventory for Chicago.

    Science.gov (United States)

    2013-04-01

    The overarching goal of this research project is to enable state DOTs to document and monitor the reliability performance : of their highway networks. To this end, a computer tool, TRIC, was developed to produce travel reliability inventories from : ...

  1. A "three-in-one" sample preparation method for simultaneous determination of B-group water-soluble vitamins in infant formula using VitaFast(®) kits.

    Science.gov (United States)

    Zhang, Heng; Lan, Fang; Shi, Yupeng; Wan, Zhi-Gang; Yue, Zhen-Feng; Fan, Fang; Lin, Yan-Kui; Tang, Mu-Jin; Lv, Jing-Zhang; Xiao, Tan; Yi, Changqing

    2014-06-15

    VitaFast(®) test kits designed for the microbiological assay in microtiter plate format can be applied to quantitative determination of B-group water-soluble vitamins such as vitamin B12, folic acid and biotin, et al. Compared to traditional microbiological methods, VitaFast(®) kits significantly reduce sample processing time and provide greater reliability, higher productivity and better accuracy. Recently, simultaneous determination of vitamin B12, folic acid and biotin in one sample is urgently required when evaluating the quality of infant formulae in our practical work. However, the present sample preparation protocols which are developed for individual test systems, are incompatible with simultaneous determination of several analytes. To solve this problem, a novel "three-in-one" sample preparation method is herein developed for simultaneous determination of B-group water-soluble vitamins using VitaFast(®) kits. The performance of this novel "three-in-one" sample preparation method was systematically evaluated through comparing with individual sample preparation protocols. The experimental results of the assays which employed "three-in-one" sample preparation method were in good agreement with those obtained from conventional VitaFast(®) extraction methods, indicating that the proposed "three-in-one" sample preparation method is applicable to the present three VitaFast(®) vitamin test systems, thus offering a promising alternative for the three independent sample preparation methods. The proposed new sample preparation method will significantly improve the efficiency of infant formulae inspection. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Comparison of the thermodynamic databases for radioactive elements in application to the calculation of the solubilities in the porewater

    International Nuclear Information System (INIS)

    Doi, Reisuke; Shibata, Masahiro

    2006-07-01

    To calculate the solubility of radioactive elements which is the important parameter for performance assessment of geological disposal system, the thermodynamic database must be reliable and based on the latest information. In this research, it has been compared in the calculation of the solubilities of the representative radioactive elements in the porewater compositions of the compacted bentonite which were set up in the second progress report (H12) that the thermodynamic database of JNC, OECD/NEA, Nagra/PSI. And the causes of the differences among the results from application of different databases were investigated and discussed. (author)

  3. Levels of soluble delta-like ligand 1 in the serum and cerebrospinal fluid of tuberculous meningitis patients

    Institute of Scientific and Technical Information of China (English)

    Jinghong Li; Jinyi Li; Yanjie Jia

    2012-01-01

    In this study, the levels of soluble delta-like ligand 1 in cerebrospinal fluid and serum of 50 patients with tuberculous meningitis, 30 patients with viral meningitis, 20 patients with purulent meningitis and 40 subjects without central nervous system disease were determined using an enzyme-linked immunosorbent assay. The mean levels of soluble delta-like ligand 1 in both cerebrospinal fluid and serum from patients with tuberculous meningitis were significantly higher compared with those from patients with viral meningitis or purulent meningitis or from subjects without central nervous system disease. Meanwhile, the level of soluble delta-like ligand 1 gradually decreased as tuberculous meningitis patients recovered. If patients deteriorated after treatment, the level of soluble delta-like ligand 1 in cerebrospinal fluid gradually increased. There was no correlation between the level of soluble delta-like ligand 1 and the protein level/cell number in cerebrospinal fluid. Our findings in-dicate that the levels of soluble delta-like ligand 1 in cerebrospinal fluid and serum are reliable markers for the diagnosis of tuberculous meningitis and for monitoring treatment progress. At the same time, this index is not influenced by protein levels or cell numbers in cerebrospinal fluid.

  4. Solubility of cobalt in primary circuit solutions

    International Nuclear Information System (INIS)

    Lambert, I.; Joyer, F.

    1992-01-01

    The solubility of cobalt ferrite (CoFe 2 O 4 ) was measured in PWR primary circuit conditions, in the temperature range 250-350 deg C, and the results were compared with the ones obtained on magnetite and nickel ferrite. As in the former cases, it was found that, in the prevailing primary circuit conditions, the solubility of the cobalt ferrite was minimum at temperatures around 300 deg C, for cobalt as well as for iron. The equilibrium iron concentration is significantly lower than in the case of magnetite. The results are discussed in relation with the POTHY code, based only on thermodynamic laws and data, used for the prediction of the primary circuit chemistry

  5. Biochemical synthesis of water soluble conducting polymers

    Science.gov (United States)

    Bruno, Ferdinando F.; Bernabei, Manuele

    2016-05-01

    An efficient biomimetic route for the synthesis of conducting polymers/copolymers complexed with lignin sulfonate and sodium (polystyrenesulfonate) (SPS) will be presented. This polyelectrolyte assisted PEG-hematin or horseradish peroxidase catalyzed polymerization of pyrrole (PYR), 3,4 ethyldioxithiophene (EDOT) and aniline has provided a route to synthesize water-soluble conducting polymers/copolymers under acidic conditions. The UV-vis, FTIR, conductivity and cyclic voltammetry studies for the polymers/copolymer complex indicated the presence of a thermally stable and electroactive polymers. Moreover, the use of water-soluble templates, used as well as dopants, provided a unique combination of properties such as high electronic conductivity, and processability. These polymers/copolymers are nowadays tested/evaluated for antirust features on airplanes and helicopters. However, other electronic applications, such as photovoltaics, for transparent conductive polyaniline, actuators, for polypyrrole, and antistatic films, for polyEDOT, will be proposed.

  6. Biochemical synthesis of water soluble conducting polymers

    Energy Technology Data Exchange (ETDEWEB)

    Bruno, Ferdinando F., E-mail: Ferdinando-Bruno@uml.edu [US Army Natick Soldier Research, Development and Engineering Center, Natick, MA 01760 (United States); Bernabei, Manuele [ITAF, Test Flight Centre, Chemistry Dept. Pratica di Mare AFB, 00071 Pomezia (Rome), Italy (UE) (Italy)

    2016-05-18

    An efficient biomimetic route for the synthesis of conducting polymers/copolymers complexed with lignin sulfonate and sodium (polystyrenesulfonate) (SPS) will be presented. This polyelectrolyte assisted PEG-hematin or horseradish peroxidase catalyzed polymerization of pyrrole (PYR), 3,4 ethyldioxithiophene (EDOT) and aniline has provided a route to synthesize water-soluble conducting polymers/copolymers under acidic conditions. The UV-vis, FTIR, conductivity and cyclic voltammetry studies for the polymers/copolymer complex indicated the presence of a thermally stable and electroactive polymers. Moreover, the use of water-soluble templates, used as well as dopants, provided a unique combination of properties such as high electronic conductivity, and processability. These polymers/copolymers are nowadays tested/evaluated for antirust features on airplanes and helicopters. However, other electronic applications, such as photovoltaics, for transparent conductive polyaniline, actuators, for polypyrrole, and antistatic films, for polyEDOT, will be proposed.

  7. Biochemical synthesis of water soluble conducting polymers

    International Nuclear Information System (INIS)

    Bruno, Ferdinando F.; Bernabei, Manuele

    2016-01-01

    An efficient biomimetic route for the synthesis of conducting polymers/copolymers complexed with lignin sulfonate and sodium (polystyrenesulfonate) (SPS) will be presented. This polyelectrolyte assisted PEG-hematin or horseradish peroxidase catalyzed polymerization of pyrrole (PYR), 3,4 ethyldioxithiophene (EDOT) and aniline has provided a route to synthesize water-soluble conducting polymers/copolymers under acidic conditions. The UV-vis, FTIR, conductivity and cyclic voltammetry studies for the polymers/copolymer complex indicated the presence of a thermally stable and electroactive polymers. Moreover, the use of water-soluble templates, used as well as dopants, provided a unique combination of properties such as high electronic conductivity, and processability. These polymers/copolymers are nowadays tested/evaluated for antirust features on airplanes and helicopters. However, other electronic applications, such as photovoltaics, for transparent conductive polyaniline, actuators, for polypyrrole, and antistatic films, for polyEDOT, will be proposed.

  8. Soluble organic nanotubes for catalytic systems

    Science.gov (United States)

    Xiong, Linfeng; Yang, Kunran; Zhang, Hui; Liao, Xiaojuan; Huang, Kun

    2016-03-01

    In this paper, we report a novel method for constructing a soluble organic nanotube supported catalyst system based on single-molecule templating of core-shell bottlebrush copolymers. Various organic or metal catalysts, such as sodium prop-2-yne-1-sulfonate (SPS), 1-(2-(prop-2-yn-1-yloxy)ethyl)-1H-imidazole (PEI) and Pd(OAc)2 were anchored onto the tube walls to functionalize the organic nanotubes via copper-catalyzed azide-alkyne cycloaddition (CuAAC) reaction. Depending on the ‘confined effect’ and the accessible cavity microenvironments of tubular structures, the organic nanotube catalysts showed high catalytic efficiency and site-isolation features. We believe that the soluble organic nanotubes will be very useful for the development of high performance catalyst systems due to their high stability of support, facile functionalization and attractive textural properties.

  9. Soluble organic nanotubes for catalytic systems.

    Science.gov (United States)

    Xiong, Linfeng; Yang, Kunran; Zhang, Hui; Liao, Xiaojuan; Huang, Kun

    2016-03-18

    In this paper, we report a novel method for constructing a soluble organic nanotube supported catalyst system based on single-molecule templating of core–shell bottlebrush copolymers. Various organic or metal catalysts, such as sodium prop-2-yne-1-sulfonate (SPS), 1-(2-(prop-2-yn-1-yloxy)ethyl)-1H-imidazole (PEI) and Pd(OAc)2 were anchored onto the tube walls to functionalize the organic nanotubes via copper-catalyzed azide-alkyne cycloaddition (CuAAC) reaction. Depending on the 'confined effect' and the accessible cavity microenvironments of tubular structures, the organic nanotube catalysts showed high catalytic efficiency and site-isolation features. We believe that the soluble organic nanotubes will be very useful for the development of high performance catalyst systems due to their high stability of support, facile functionalization and attractive textural properties.

  10. Investigation of solubility of carbon dioxide in anhydrous milk fat by lab-scale manometric method.

    Science.gov (United States)

    Truong, Tuyen; Palmer, Martin; Bansal, Nidhi; Bhandari, Bhesh

    2017-12-15

    This study aims to examine the solubility of CO 2 in anhydrous milk fat (AMF) as functions of partial pressure, temperature, chemical composition and physical state of AMF. AMF was fractionated at 21°C to obtain stearin and olein fractions. The CO 2 solubility was measured using a home-made experimental apparatus based on changes of CO 2 partial pressures. The apparatus was found to be reliable as the measured and theoretical values based on the ideal gas law were comparable. The dissolved CO 2 concentration in AMF increased with an increase in CO 2 partial pressure (0-101kPa). The apparent CO 2 solubility coefficients (molkg -1 Pa -1 ) in the AMF were 5.75±0.16×10 -7 , 3.9±0.19×10 -7 and 1.19±0.14×10 -7 at 35, 24 and 4°C, respectively. Higher liquid oil proportions resulted in higher CO 2 solubility in the AMF. There was insignificant difference in the dissolved CO 2 concentration among the AMF, stearin and olein fractions in their liquid state at 40°C. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Hydrogen solubility measurements of analyzed tall oil fractions and a solubility model

    International Nuclear Information System (INIS)

    Uusi-Kyyny, Petri; Pakkanen, Minna; Linnekoski, Juha; Alopaeus, Ville

    2017-01-01

    Highlights: • Hydrogen solubility was measured in four tall oil fractions between 373 and 597 K. • Continuous flow synthetic isothermal and isobaric method was used. • A Henry’s law model was developed for the distilled tall oil fractions. • The complex composition of the samples was analyzed and is presented. - Abstract: Knowledge of hydrogen solubility in tall oil fractions is important for designing hydrotreatment processes of these complex nonedible biobased materials. Unfortunately measurements of hydrogen solubility into these fractions are missing in the literature. This work reports hydrogen solubility measured in four tall oil fractions between 373 and 597 K and at pressures from 5 to 10 MPa. Three of the fractions were distilled tall oil fractions their resin acids contents are respectively 2, 20 and 23 in mass-%. Additionally one fraction was a crude tall oil (CTO) sample containing sterols as the main neutral fraction. Measurements were performed using a continuous flow synthetic isothermal and isobaric method based on the visual observation of the bubble point. Composition of the flow was changed step-wise for the bubble point composition determination. We assume that the tall oil fractions did not react during measurements, based on the composition analysis performed before and after the measurements. Additionally the densities of the fractions were measured at atmospheric pressure from 293.15 to 323.15 K. A Henry’s law model was developed for the distilled tall oil fractions describing the solubility with an absolute average deviation of 2.1%. Inputs of the solubility model are temperature, total pressure and the density of the oil at 323.15 K. The solubility of hydrogen in the CTO sample can be described with the developed model with an absolute average deviation of 3.4%. The solubility of hydrogen increases both with increasing pressure and/or increasing temperature. The more dense fractions of the tall oil exhibit lower hydrogen

  12. 2017 NREL Photovoltaic Reliability Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-15

    NREL's Photovoltaic (PV) Reliability Workshop (PVRW) brings together PV reliability experts to share information, leading to the improvement of PV module reliability. Such improvement reduces the cost of solar electricity and promotes investor confidence in the technology -- both critical goals for moving PV technologies deeper into the electricity marketplace.

  13. AECL's reliability and maintainability program

    International Nuclear Information System (INIS)

    Wolfe, W.A.; Nieuwhof, G.W.E.

    1976-05-01

    AECL's reliability and maintainability program for nuclear generating stations is described. How the various resources of the company are organized to design and construct stations that operate reliably and safely is shown. Reliability and maintainability includes not only special mathematically oriented techniques, but also the technical skills and organizational abilities of the company. (author)

  14. Solubility and Permeability Studies of Aceclofenac in Different Oils

    African Journals Online (AJOL)

    The solubility and permeability of aceclofenac were compared with the hydroalcoholic solution of ... the use of lipid based systems such as micro- or .... carriers/vehicles for enhanced solubility and permeability ... modifications: A recent review.

  15. Soluble L-selectin levels predict survival in sepsis

    DEFF Research Database (Denmark)

    Seidelin, Jakob B; Nielsen, Ole H; Strøm, Jens

    2002-01-01

    To evaluate serum soluble L-selectin as a prognostic factor for survival in patients with sepsis.......To evaluate serum soluble L-selectin as a prognostic factor for survival in patients with sepsis....

  16. Soluble polymer conjugates for drug delivery.

    Science.gov (United States)

    Minko, Tamara

    2005-01-01

    The use of water-soluble polymeric conjugates as drug carriers offers several possible advantages. These advantages include: (1) improved drug pharmacokinetics; (2) decreased toxicity to healthy organs; (3) possible facilitation of accumulation and preferential uptake by targeted cells; (4) programmed profile of drug release. In this review, we will consider the main types of useful polymeric conjugates and their role and effectiveness as carriers in drug delivery systems.: © 2005 Elsevier Ltd . All rights reserved.

  17. Measurement of Soluble Biomarkers by Flow Cytometry

    OpenAIRE

    Antal-Szalm?s, P?ter; Nagy, B?la; Debreceni, Ildik? Beke; Kappelmayer, J?nos

    2013-01-01

    Microparticle based flow cytometric assays for determination of the level of soluble biomarkers are widely used in several research applications and in some diagnostic setups. The major advantages of these multiplex systems are that they can measure a large number of analytes (up to 500) at the same time reducing assay time, costs and sample volume. Most of these assays are based on antigen-antibody interactions and work as traditional immunoassays, but nucleic acid alterations ? by using spe...

  18. Water Soluble Polymers for Pharmaceutical Applications

    OpenAIRE

    Veeran Gowda Kadajji; Guru V. Betageri

    2011-01-01

    Advances in polymer science have led to the development of novel drug delivery systems. Some polymers are obtained from natural resources and then chemically modified for various applications, while others are chemically synthesized and used. A large number of natural and synthetic polymers are available. In the present paper, only water soluble polymers are described. They have been explained in two categories (1) synthetic and (2) natural. Drug polymer conjugates, block copolymers, hydrogel...

  19. Solubility of plutonium and waste evaporation

    International Nuclear Information System (INIS)

    Karraker, D.G.

    1993-01-01

    Chemical processing of irradiated reactor elements at the Savannah River Site separates uranium, plutonium and fission products; fission products and process-added chemicals are mixed with an excess of NaOH and discharged as a basic slurry into large underground tanks for temporary storage. The slurry is composed of base-insoluble solids that settle to the bottom of the tank; the liquid supemate contains a mixture of base-soluble chemicals--nitrates, nitrites aluminate, sulfate, etc. To conserve space in the waste tanks, the supemate is concentrated by evaporation. As the evaporation proceeds, the solubilities of some components are exceeded, and these species crystallize from solution. Normally, these components are soluble in the hot solution discharged from the waste tank evaporator and do not crystallize until the solution cools. However, concern was aroused at West Valley over the possibility that plutonium would precipitate and accumulate in the evaporator, conceivably to the point that a nuclear accident was possible. There is also a concern at SRS from evaporation of sludge washes, which arise from washing the base-insoluble solids (open-quote sludge close-quote) with ca. 1M NaOH to reduce the Al and S0 4 -2 content. The sludge washes of necessity extract a low level of Pu from the sludge and are evaporated to reduce their volume, presenting the possibility of precipitating Pu. Measurements of the solubility of Pu in synthetic solutions of similar composition to waste supernate and sludge washes are described in this report

  20. Business of reliability

    Science.gov (United States)

    Engel, Pierre

    1999-12-01

    The presentation is organized around three themes: (1) The decrease of reception equipment costs allows non-Remote Sensing organization to access a technology until recently reserved to scientific elite. What this means is the rise of 'operational' executive agencies considering space-based technology and operations as a viable input to their daily tasks. This is possible thanks to totally dedicated ground receiving entities focusing on one application for themselves, rather than serving a vast community of users. (2) The multiplication of earth observation platforms will form the base for reliable technical and financial solutions. One obstacle to the growth of the earth observation industry is the variety of policies (commercial versus non-commercial) ruling the distribution of the data and value-added products. In particular, the high volume of data sales required for the return on investment does conflict with traditional low-volume data use for most applications. Constant access to data sources supposes monitoring needs as well as technical proficiency. (3) Large volume use of data coupled with low- cost equipment costs is only possible when the technology has proven reliable, in terms of application results, financial risks and data supply. Each of these factors is reviewed. The expectation is that international cooperation between agencies and private ventures will pave the way for future business models. As an illustration, the presentation proposes to use some recent non-traditional monitoring applications, that may lead to significant use of earth observation data, value added products and services: flood monitoring, ship detection, marine oil pollution deterrent systems and rice acreage monitoring.

  1. Aluminum Solubility in Complex Electrolytes - 13011

    Energy Technology Data Exchange (ETDEWEB)

    Agnew, S.F. [Columbia Energy and Environmental Services, Inc., 1806 Terminal Dr., Richland, WA 99354 (United States); Johnston, C.T. [Dept. of Crop, Soil, and Environmental Sciences, Purdue University, West Lafayette, IN 47907 (United States)

    2013-07-01

    Predicting aluminum solubility for Hanford and Savannah River waste liquids is very important for their disposition. It is a key mission goal at each Site to leach as much aluminum as practical from sludges in order to minimize the amount of vitrified high level waste. And it is correspondingly important to assure that any soluble aluminum does not precipitate during subsequent decontamination of the liquid leachates with ion exchange. This report shows a very simple and yet thermodynamic model for aluminum solubility that is consistent with a wide range of Al liquors, from simple mixtures of hydroxide and aluminate to over 300 Hanford concentrates and to a set of 19 Bayer liquors for temperatures from 20-100 deg. C. This dimer-dS{sub mix} (DDS) model incorporates an ideal entropy of mixing along with previous reports for the Al dimer, water activities, gibbsite, and bayerite thermodynamics. We expect this model will have broad application for nuclear wastes as well as the Bayer gibbsite process industry. (authors)

  2. Hydrogen adsorption on and solubility in graphites

    International Nuclear Information System (INIS)

    Kanashenko, S.L.; Wampler, W.R.

    1996-01-01

    The experimental data on adsorption and solubility of hydrogen isotopes in graphite over a wide range of temperatures and pressures are reviewed. Langmuir adsorption isotherms are proposed for the hydrogen-graphite interaction. The entropy and enthalpy of adsorption are estimated, allowing for effects of relaxation of dangling sp 2 bonds. Three kinds of traps are proposed: edge carbon atoms of interstitial loops with an adsorption enthalpy relative to H 2 gas of -4.4 eV/H 2 (unrelaxed, Trap 1), edge carbon atoms at grain surfaces with an adsorption enthalpy of -2.3 eV/H 2 (relaxed, Trap 2), and basal plane adsorption sites with an enthalpy of +2.43 eV/H 2 (Trap 3). The adsorption capacity of different types of graphite depends on the concentration of traps which depends on the crystalline microstructure of the material. The number of potential sites for the 'true solubility' (Trap 3) is assumed to be about one site per carbon atom in all types of graphite, but the endothermic character of this solubility leads to a negligible H inventory compared to the concentration of hydrogen in type 1 and type 2 traps for temperatures and gas pressures used in the experiments. Irradiation with neutrons or carbon atoms increases the concentration of type 1 and type 2 traps from about 20 and 200 appm respectively for unirradiated (POCO AXF-5Q) graphite to about 1500 and 5000 appm, respectively, at damage levels above 1 dpa. (orig.)

  3. Soluble Aβ aggregates can inhibit prion propagation.

    Science.gov (United States)

    Sarell, Claire J; Quarterman, Emma; Yip, Daniel C-M; Terry, Cassandra; Nicoll, Andrew J; Wadsworth, Jonathan D F; Farrow, Mark A; Walsh, Dominic M; Collinge, John

    2017-11-01

    Mammalian prions cause lethal neurodegenerative diseases such as Creutzfeldt-Jakob disease (CJD) and consist of multi-chain assemblies of misfolded cellular prion protein (PrP C ). Ligands that bind to PrP C can inhibit prion propagation and neurotoxicity. Extensive prior work established that certain soluble assemblies of the Alzheimer's disease (AD)-associated amyloid β-protein (Aβ) can tightly bind to PrP C , and that this interaction may be relevant to their toxicity in AD. Here, we investigated whether such soluble Aβ assemblies might, conversely, have an inhibitory effect on prion propagation. Using cellular models of prion infection and propagation and distinct Aβ preparations, we found that the form of Aβ assemblies which most avidly bound to PrP in vitro also inhibited prion infection and propagation. By contrast, forms of Aβ which exhibit little or no binding to PrP were unable to attenuate prion propagation. These data suggest that soluble aggregates of Aβ can compete with prions for binding to PrP C and emphasize the bidirectional nature of the interplay between Aβ and PrP C in Alzheimer's and prion diseases. Such inhibitory effects of Aβ on prion propagation may contribute to the apparent fall-off in the incidence of sporadic CJD at advanced age where cerebral Aβ deposition is common. © 2017 The Authors.

  4. Solubility of plutonium dioxide aerosols, in vitro

    International Nuclear Information System (INIS)

    Newton, G.J.; Kanapilly, G.M.

    1976-01-01

    Solubility of plutonium aerosols is an important parameter in establishing risk estimates for industrial workers who might accidentally inhale these materials and in evaluating environmental health impacts associated with Pu. In vitro solubility of industrial plutonium aerosols in a simulated lung fluid is compared to similar studies with ultrafine aerosols from laser ignition of delta phase plutonium metal and laboratory-produced spherical particles of 238 PuO 2 and 239 PuO 2 . Although relatively insoluble, industrial plutonium-mixed oxide aerosols were much more soluble than laboratory-produced plutonium dioxide particles. Chain agglomerate aerosols from laser ignition of metallic Pu indicated in vitro dissolution half-times of 10 and 50 days for activity median aerodynamic diameter (AMAD) of 0.7 and 2.3 μm, respectively. Plutonium-containing mixed oxide aerosols indicated dissolution half-times of 40 to 500 days for particles formed by industrial powder comminution and blending. Centerless grinding of fuel pellets yielded plutonium-containing aerosols with dissolution half-times of 1200 to 8000 days. All mixed oxide particles were in the size range 1.0 μm to 2.5 μm AMAD

  5. Reliability and Validity of Qualitative and Operational Research Paradigm

    Directory of Open Access Journals (Sweden)

    Muhammad Bashir

    2008-01-01

    Full Text Available Both qualitative and quantitative paradigms try to find the same result; the truth. Qualitative studies are tools used in understanding and describing the world of human experience. Since we maintain our humanity throughout the research process, it is largely impossible to escape the subjective experience, even for the most experienced of researchers. Reliability and Validity are the issue that has been described in great deal by advocates of quantitative researchers. The validity and the norms of rigor that are applied to quantitative research are not entirely applicable to qualitative research. Validity in qualitative research means the extent to which the data is plausible, credible and trustworthy; and thus can be defended when challenged. Reliability and validity remain appropriate concepts for attaining rigor in qualitative research. Qualitative researchers have to salvage responsibility for reliability and validity by implementing verification strategies integral and self-correcting during the conduct of inquiry itself. This ensures the attainment of rigor using strategies inherent within each qualitative design, and moves the responsibility for incorporating and maintaining reliability and validity from external reviewers’ judgments to the investigators themselves. There have different opinions on validity with some suggesting that the concepts of validity is incompatible with qualitative research and should be abandoned while others argue efforts should be made to ensure validity so as to lend credibility to the results. This paper is an attempt to clarify the meaning and use of reliability and validity in the qualitative research paradigm.

  6. The aqueous solubility and speciation analysis for uranium, neptunium and selenium by the geochemical code(EQ3/6)

    International Nuclear Information System (INIS)

    Takeda, Seiji; Shima, Shigeki; Kimura, Hideo; Matsuzuru, Hideo

    1995-11-01

    The geochemical condition of a geologic disposal system of HLW controls the solubility and physicochemical forms of dominant aqueous species for elements, which are one of essential information required for safety assessment. Based on the measured compositions of groundwater, the compositions of groundwater in the disposal system were calculated. The solubility and speciation analyses for the polyvalent elements, uranium, neptunium, and selenium, were performed by the geochemical code EQ3/6. The results obtained were compared with the data appeared in the literatures on the solubilities and speciations. The geochemical behaviors of the elements with respect to the solubility and speciation could quantitatively be elucidated for the compositions of the interstitial waters in an engineered barrier and ground water in a natural barrier. In the pH range of neutral to alkali, the solubilities of U and Np tend to increase with an increase of the carbonate concentration in groundwater. This carbonate concentration dependence of the solubility was also estimated. In the engineered barrier the predominant aqueous species were specified, and in the natural barrier the change of aqueous species was also predicted while the chemical compositions changed from the reducing to oxidizing conditions. The dominant aqueous species for the elements, which migrate in and through the disposal system, were determined by the speciation analysis. (author)

  7. Quantitative analysis chemistry

    International Nuclear Information System (INIS)

    Ko, Wansuk; Lee, Choongyoung; Jun, Kwangsik; Hwang, Taeksung

    1995-02-01

    This book is about quantitative analysis chemistry. It is divided into ten chapters, which deal with the basic conception of material with the meaning of analysis chemistry and SI units, chemical equilibrium, basic preparation for quantitative analysis, introduction of volumetric analysis, acid-base titration of outline and experiment examples, chelate titration, oxidation-reduction titration with introduction, titration curve, and diazotization titration, precipitation titration, electrometric titration and quantitative analysis.

  8. Solubility of Meloxicam in Mixed Solvent Systems | Babu | Ethiopian ...

    African Journals Online (AJOL)

    The solubility of meloxicam is higher in phosphate buffer (pH 7.4) compared to water, probably due to ionization of the drug. The solubility of meloxicam is marginally enhanced in surfactant systems (Tween 80 and Brij 35) at concentrations higher than cmc, proving the micellar solubilization. Meloxicam solubility studies in ...

  9. The Hildebrand Solubility Parameters of Ionic Liquids—Part 2

    Science.gov (United States)

    Marciniak, Andrzej

    2011-01-01

    The Hildebrand solubility parameters have been calculated for eight ionic liquids. Retention data from the inverse gas chromatography measurements of the activity coefficients at infinite dilution were used for the calculation. From the solubility parameters, the enthalpies of vaporization of ionic liquids were estimated. Results are compared with solubility parameters estimated by different methods. PMID:21747694

  10. The Hildebrand solubility parameters of ionic liquids-part 2.

    Science.gov (United States)

    Marciniak, Andrzej

    2011-01-01

    The Hildebrand solubility parameters have been calculated for eight ionic liquids. Retention data from the inverse gas chromatography measurements of the activity coefficients at infinite dilution were used for the calculation. From the solubility parameters, the enthalpies of vaporization of ionic liquids were estimated. Results are compared with solubility parameters estimated by different methods.

  11. The Hildebrand Solubility Parameters of Ionic Liquids—Part 2

    Directory of Open Access Journals (Sweden)

    Andrzej Marciniak

    2011-06-01

    Full Text Available The Hildebrand solubility parameters have been calculated for eight ionic liquids. Retention data from the inverse gas chromatography measurements of the activity coefficients at infinite dilution were used for the calculation. From the solubility parameters, the enthalpies of vaporization of ionic liquids were estimated. Results are compared with solubility parameters estimated by different methods.

  12. Quantitative Algebraic Reasoning

    DEFF Research Database (Denmark)

    Mardare, Radu Iulian; Panangaden, Prakash; Plotkin, Gordon

    2016-01-01

    We develop a quantitative analogue of equational reasoning which we call quantitative algebra. We define an equality relation indexed by rationals: a =ε b which we think of as saying that “a is approximately equal to b up to an error of ε”. We have 4 interesting examples where we have a quantitative...... equational theory whose free algebras correspond to well known structures. In each case we have finitary and continuous versions. The four cases are: Hausdorff metrics from quantitive semilattices; pWasserstein metrics (hence also the Kantorovich metric) from barycentric algebras and also from pointed...

  13. Quantitative autoradiography of neurochemicals

    International Nuclear Information System (INIS)

    Rainbow, T.C.; Biegon, A.; Bleisch, W.V.

    1982-01-01

    Several new methods have been developed that apply quantitative autoradiography to neurochemistry. These methods are derived from the 2-deoxyglucose (2DG) technique of Sokoloff (1), which uses quantitative autoradiography to measure the rate of glucose utilization in brain structures. The new methods allow the measurement of the rate of cerbral protein synthesis and the levels of particular neurotransmitter receptors by quantitative autoradiography. As with the 2DG method, the new techniques can measure molecular levels in micron-sized brain structures; and can be used in conjunction with computerized systems of image processing. It is possible that many neurochemical measurements could be made by computerized analysis of quantitative autoradiograms

  14. Electronics reliability calculation and design

    CERN Document Server

    Dummer, Geoffrey W A; Hiller, N

    1966-01-01

    Electronics Reliability-Calculation and Design provides an introduction to the fundamental concepts of reliability. The increasing complexity of electronic equipment has made problems in designing and manufacturing a reliable product more and more difficult. Specific techniques have been developed that enable designers to integrate reliability into their products, and reliability has become a science in its own right. The book begins with a discussion of basic mathematical and statistical concepts, including arithmetic mean, frequency distribution, median and mode, scatter or dispersion of mea

  15. State of the art report on aging reliability analysis

    International Nuclear Information System (INIS)

    Choi, Sun Yeong; Yang, Joon Eon; Han, Sang Hoon; Ha, Jae Joo

    2002-03-01

    The goal of this report is to describe the state of the art on aging analysis methods to calculate the effects of component aging quantitatively. In this report, we described some aging analysis methods which calculate the increase of Core Damage Frequency (CDF) due to aging by including the influence of aging into PSA. We also described several research topics required for aging analysis for components of domestic NPPs. We have described a statistical model and reliability physics model which calculate the effect of aging quantitatively by using PSA method. It is expected that the practical use of the reliability-physics model will be increased though the process with the reliability-physics model is more complicated than statistical model

  16. Aqueous solubility, dispersibility and toxicity of biodiesels

    International Nuclear Information System (INIS)

    Hollebone, B.P.; Fieldhouse, B.; Lumley, T.C.; Landriault, M.; Doe, K.; Jackman, P.

    2007-01-01

    The renewed interest in the use of biological fuels can be attributed to that fact that feedstocks for fatty-acid ester biodiesels are renewable and can be reclaimed from waste. Although there are significant benefits to using biodiesels, their increased use leaves potential for accidental release to the environment. Therefore, their environmental behaviours and impacts must be evaluated along with the risk associated with their use. Biodiesel fuels may be made from soy oil, canola oil, reclaimed restaurant grease, fish oil and animal fat. The toxicological fate of biofuel depends on the variability of its chemical composition. This study provided an initial assessment of the aqueous fate and effects of biodiesel from a broad range of commonly available feedstocks and their blends with petroleum diesels. The study focused primarily on the fate and impact of these fuels in fresh-water. The use of chemical dispersion as a countermeasure for saltwater was also investigated. The exposure of aquatic ecosystems to biodiesels and petroleum diesel occurs via the transfer of material from the non-aqueous phase liquid (NAPL) into the aqueous phase, as both soluble and dispersed components. The aqueous solubilities of the fuels were determined from the equilibrium water-accommodated fraction concentrations. The acute toxicities of many biodiesels were reported for 3 test species used by Environment Canada for toxicological evaluation, namely rainbow trout, the water flea and a luminescent bacterium. This study also evaluated the natural potential for dispersion of the fuels in the water column in both low and high-energy wave conditions. Chemical dispersion as a potential countermeasure for biodiesel spills was also evaluated using solubility testing, acute toxicity testing, and dispersibility testing. It was shown that biodiesels have much different fates and impacts from petroleum diesels. The compounds partitioning into the water column are also very different for each

  17. Separation of lipoproteins for quantitative analysis of 14C-labeled lipid soluble compounds

    Science.gov (United States)

    Carbon-14 tracer studies using accelerator mass spectrometry (AMS) have provided novel insights into nutrient metabolism and whole body metabolite flux. In addition to a baseline separation of analytes, a critical requirement specific to the AMS analysis was a stable carbon baseline within the anal...

  18. Simulated rat intestinal fluid improves oral exposure prediction for poorly soluble compounds over a wide dose range

    Directory of Open Access Journals (Sweden)

    Joerg Berghausen

    2016-03-01

    Full Text Available Solubility can be the absorption limiting factor for drug candidates and is therefore a very important input parameter for oral exposure prediction of compounds with limited solubility. Biorelevant media of the fasted and fed state have been published for humans, as well as for dogs in the fasted state. In a drug discovery environment, rodents are the most common animal model to assess the oral exposure of drug candidates. In this study a rat simulated intestinal fluid (rSIF is proposed as a more physiologically relevant media to describe drug solubility in rats. Equilibrium solubility in this medium was tested as input parameter for physiologically-based pharmacokinetics (PBPK simulations of oral pharmacokinetics in the rat. Simulations were compared to those obtained using other solubility values as input parameters, like buffer at pH 6.8, human simulated intestinal fluid and a comprehensive dissolution assay based on rSIF. Our study on nine different compounds demonstrates that the incorporation of rSIF equilibrium solubility values into PBPK models of oral drug exposure can significantly improve the reliability of simulations in rats for doses up to 300 mg/kg compared to other media. The comprehensive dissolution assay may help to improve further simulation outcome, but the greater experimental effort as compared to equilibrium solubility may limit its use in a drug discovery environment. Overall, PBPK simulations based on solubility in the proposed rSIF medium can improve prioritizing compounds in drug discovery as well as planning dose escalation studies, e.g. during toxicological investigations.

  19. Mathematical reliability an expository perspective

    CERN Document Server

    Mazzuchi, Thomas; Singpurwalla, Nozer

    2004-01-01

    In this volume consideration was given to more advanced theoretical approaches and novel applications of reliability to ensure that topics having a futuristic impact were specifically included. Topics like finance, forensics, information, and orthopedics, as well as the more traditional reliability topics were purposefully undertaken to make this collection different from the existing books in reliability. The entries have been categorized into seven parts, each emphasizing a theme that seems poised for the future development of reliability as an academic discipline with relevance. The seven parts are networks and systems; recurrent events; information and design; failure rate function and burn-in; software reliability and random environments; reliability in composites and orthopedics, and reliability in finance and forensics. Embedded within the above are some of the other currently active topics such as causality, cascading, exchangeability, expert testimony, hierarchical modeling, optimization and survival...

  20. Poly(aspartic acid) with adjustable pH-dependent solubility.

    Science.gov (United States)

    Németh, Csaba; Gyarmati, Benjámin; Abdullin, Timur; László, Krisztina; Szilágyi, András

    2017-02-01

    Poly(aspartic acid) (PASP) derivatives with adjustable pH-dependent solubility were synthesized and characterized to establish the relationship between their structure and solubility in order to predict their applicability as a basic material for enteric coatings. Polysuccinimide, the precursor of PASP, was modified with short chain alkylamines, and the residual succinimide rings were subsequently opened to prepare the corresponding PASP derivatives. Study of the effect of the type and concentration of the side groups on the pH-dependent solubility of PASP showed that solubility can be adjusted by proper selection of the chemical structure. The Henderson-Hasselbalch (HH) and the extended HH equations were used to describe the pH-dependent solubility of the polymers quantitatively. The estimate provided by the HH equation is poor, but an accurate description of the pH-dependent solubility can be found with the extended HH equation. The dissolution rate of a polymer film prepared from a selected PASP derivative was determined by fluorescence marking. The film dissolved rapidly when the pH was increased above its pK a . Cellular viability tests show that PASP derivatives are non-toxic to a human cell line. These polymers are thus of great interest as starting materials for enteric coatings. Poly(amino acid) type biocompatible polymers were synthesized for future use as pharmaceutical film coatings. To this end, we tailored the pH-dependent solubility of poly(aspartic acid) (PASP). It was found that both the solubility and the pK a values of the modified PASP depended strongly on composition. Fluorescent marking was used to characterize the dissolution of a chosen PASP derivative. In acidic media only a negligible amount of the polymer dissolved, but dissolution was very fast and complete at the pH values that prevail in the small intestine. As a consequence, enteric coatings based on such PASP derivatives may be used for drug delivery in the gastrointestinal tract

  1. Effect of composition of simulated intestinal media on the solubility of poorly soluble compounds investigated by design of experiments

    DEFF Research Database (Denmark)

    Madsen, Cecilie Maria; Feng, Kung-I; Leithead, Andrew

    2018-01-01

    The composition of the human intestinal fluids varies both intra- and inter-individually. This will influence the solubility of orally administered drug compounds, and hence, the absorption and efficacy of compounds displaying solubility limited absorption. The purpose of this study was to assess...... studies feasible compared to single SIF solubility studies. Applying this DoE approach will lead to a better understanding of the impact of intestinal fluid composition on the solubility of a given drug compound....

  2. Of plants and reliability

    International Nuclear Information System (INIS)

    Schneider Horst

    2009-01-01

    Behind the political statements made about the transformer event at the Kruemmel nuclear power station (KKK) in the summer of 2009 there are fundamental issues of atomic law. Pursuant to Articles 20 and 28 of its Basic Law, Germany is a state in which the rule of law applies. Consequently, the aspects of atomic law associated with the incident merit a closer look, all the more so as the items concerned have been known for many years. Important aspects in the debate about the Kruemmel nuclear power plant are the fact that the transformer is considered part of the nuclear power station under atomic law and thus a ''plant'' subject to surveillance by the nuclear regulatory agencies, on the one hand, and the reliability under atomic law of the operator and the executive personnel responsible, on the other hand. Both ''plant'' and ''reliability'' are terms focusing on nuclear safety. Hence the question to what extent safety was affected in the Kruemmel incident. The classification of the event as 0 = no or only a very slight safety impact on the INES scale (INES = International Nuclear Event Scale) should not be used to put aside the safety issue once and for all. Points of fact and their technical significance must be considered prior to any legal assessment. Legal assessments and regulations are associated with facts and circumstances. Any legal examination is based on the facts as determined and elucidated. Any other procedure would be tantamount to an inadmissible legal advance conviction. Now, what is the position of political statements, i.e. political assessments and political responsibility? If everything is done the correct way, they come at the end, after exploration of the facts and evaluation under applicable law. Sometimes things are handled differently, with consequences which are not very helpful. In the light of the provisions about the rule of law as laid down in the Basic Law, the new federal government should be made to observe the proper sequence of

  3. OSMOTIC COEFFICIENTS, SOLUBILITIES, AND DELIQUESCENCE RELATIONS IN MIXED AQUEOUS SALT SOLUTIONS AT ELEVATED TEMPERATURE

    International Nuclear Information System (INIS)

    M.S. Gruszkiewicz; D.A. Palmer

    2006-01-01

    While thermodynamic properties of pure aqueous electrolytes are relatively well known at ambient temperature, there are far fewer data for binary systems extending to elevated temperatures and high concentrations. There is no general theoretically sound basis for prediction of the temperature dependence of ionic activities, and consequently temperature extrapolations based on ambient temperature data and empirical equations are uncertain and require empirical verification. Thermodynamic properties of mixed brines in a wide range of concentrations would enhance the understanding and precise modeling of the effects of deliquescence of initially dry solids in humid air in geological environments and in modeling the composition of waters during heating, cooling, evaporation or condensation processes. These conditions are of interest in the analysis of waters on metal surfaces at the proposed radioactive waste repository at Yucca Mountain, Nevada. The results obtained in this project will be useful for modeling the long-term evolution of the chemical environment, and this in turn is useful for the analysis of the corrosion of waste packages. In particular, there are few reliable experimental data available on the relationship between relative humidity and composition that reveals the eutonic points of the mixtures and the mixture deliquescence RH. The deliquescence RH for multicomponent mixtures is lower than that of pure component or binary solutions, but is not easy to predict quantitatively since the solutions are highly nonideal. In this work we used the ORNL low-temperature and high-temperature isopiestic facilities, capable of precise measurements of vapor pressure between ambient temperature and 250 C for determination of not only osmotic coefficients, but also solubilities and deliquescence points of aqueous mixed solutions in a range of temperatures. In addition to standard solutions of CaCl 2 , LiCl, and NaCl used as references, precise direct

  4. The solubility-permeability interplay and its implications in formulation design and development for poorly soluble drugs.

    Science.gov (United States)

    Dahan, Arik; Miller, Jonathan M

    2012-06-01

    While each of the two key parameters of oral drug absorption, the solubility and the permeability, has been comprehensively studied separately, the relationship and interplay between the two have been largely ignored. For instance, when formulating a low-solubility drug using various solubilization techniques: what are we doing to the apparent permeability when we increase the solubility? Permeability is equal to the drug's diffusion coefficient through the membrane times the membrane/aqueous partition coefficient divided by the membrane thickness. The direct correlation between the intestinal permeability and the membrane/aqueous partitioning, which in turn is dependent on the drug's apparent solubility in the GI milieu, suggests that the solubility and the permeability are closely associated, exhibiting a certain interplay between them, and the current view of treating the one irrespectively of the other may not be sufficient. In this paper, we describe the research that has been done thus far, and present new data, to shed light on this solubility-permeability interplay. It has been shown that decreased apparent permeability accompanies the solubility increase when using different solubilization methods. Overall, the weight of the evidence indicates that the solubility-permeability interplay cannot be ignored when using solubility-enabling formulations; looking solely at the solubility enhancement that the formulation enables may be misleading with regards to predicting the resulting absorption, and hence, the solubility-permeability interplay must be taken into account to strike the optimal solubility-permeability balance, in order to maximize the overall absorption.

  5. Head-To-Head Comparison of Different Solubility-Enabling Formulations of Etoposide and Their Consequent Solubility-Permeability Interplay.

    Science.gov (United States)

    Beig, Avital; Miller, Jonathan M; Lindley, David; Carr, Robert A; Zocharski, Philip; Agbaria, Riad; Dahan, Arik

    2015-09-01

    The purpose of this study was to conduct a head-to-head comparison of different solubility-enabling formulations, and their consequent solubility-permeability interplay. The low-solubility anticancer drug etoposide was formulated in several strengths of four solubility-enabling formulations: hydroxypropyl-β-cyclodextrin, the cosolvent polyethylene glycol 400 (PEG-400), the surfactant sodium lauryl sulfate, and an amorphous solid dispersion formulation. The ability of these formulations to increase the solubility of etoposide was investigated, followed by permeability studies using the parallel artificial membrane permeability assay (PAMPA) and examination of the consequent solubility-permeability interplay. All formulations significantly increased etoposide's apparent solubility. The cyclodextrin-, surfactant-, and cosolvent-based formulations resulted in a concomitant decreased permeability that could be modeled directly from the proportional increase in the apparent solubility. On the contrary, etoposide permeability remained constant when using the ASD formulation, irrespective of the increased apparent solubility provided by the formulation. In conclusion, supersaturation resulting from the amorphous form overcomes the solubility-permeability tradeoff associated with other formulation techniques. Accounting for the solubility-permeability interplay may allow to develop better solubility-enabling formulations, thereby maximizing the overall absorption of lipophilic orally administered drugs. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  6. Multinomial-exponential reliability function: a software reliability model

    International Nuclear Information System (INIS)

    Saiz de Bustamante, Amalio; Saiz de Bustamante, Barbara

    2003-01-01

    The multinomial-exponential reliability function (MERF) was developed during a detailed study of the software failure/correction processes. Later on MERF was approximated by a much simpler exponential reliability function (EARF), which keeps most of MERF mathematical properties, so the two functions together makes up a single reliability model. The reliability model MERF/EARF considers the software failure process as a non-homogeneous Poisson process (NHPP), and the repair (correction) process, a multinomial distribution. The model supposes that both processes are statistically independent. The paper discusses the model's theoretical basis, its mathematical properties and its application to software reliability. Nevertheless it is foreseen model applications to inspection and maintenance of physical systems. The paper includes a complete numerical example of the model application to a software reliability analysis

  7. Estimation of structural reliability under combined loads

    International Nuclear Information System (INIS)

    Shinozuka, M.; Kako, T.; Hwang, H.; Brown, P.; Reich, M.

    1983-01-01

    For the overall safety evaluation of seismic category I structures subjected to various load combinations, a quantitative measure of the structural reliability in terms of a limit state probability can be conveniently used. For this purpose, the reliability analysis method for dynamic loads, which has recently been developed by the authors, was combined with the existing standard reliability analysis procedure for static and quasi-static loads. The significant parameters that enter into the analysis are: the rate at which each load (dead load, accidental internal pressure, earthquake, etc.) will occur, its duration and intensity. All these parameters are basically random variables for most of the loads to be considered. For dynamic loads, the overall intensity is usually characterized not only by their dynamic components but also by their static components. The structure considered in the present paper is a reinforced concrete containment structure subjected to various static and dynamic loads such as dead loads, accidental pressure, earthquake acceleration, etc. Computations are performed to evaluate the limit state probabilities under each load combination separately and also under all possible combinations of such loads

  8. Stochastic models in reliability and maintenance

    CERN Document Server

    2002-01-01

    Our daily lives can be maintained by the high-technology systems. Computer systems are typical examples of such systems. We can enjoy our modern lives by using many computer systems. Much more importantly, we have to maintain such systems without failure, but cannot predict when such systems will fail and how to fix such systems without delay. A stochastic process is a set of outcomes of a random experiment indexed by time, and is one of the key tools needed to analyze the future behavior quantitatively. Reliability and maintainability technologies are of great interest and importance to the maintenance of such systems. Many mathematical models have been and will be proposed to describe reliability and maintainability systems by using the stochastic processes. The theme of this book is "Stochastic Models in Reliability and Main­ tainability. " This book consists of 12 chapters on the theme above from the different viewpoints of stochastic modeling. Chapter 1 is devoted to "Renewal Processes," under which cla...

  9. Data Used in Quantified Reliability Models

    Science.gov (United States)

    DeMott, Diana; Kleinhammer, Roger K.; Kahn, C. J.

    2014-01-01

    Data is the crux to developing quantitative risk and reliability models, without the data there is no quantification. The means to find and identify reliability data or failure numbers to quantify fault tree models during conceptual and design phases is often the quagmire that precludes early decision makers consideration of potential risk drivers that will influence design. The analyst tasked with addressing a system or product reliability depends on the availability of data. But, where is does that data come from and what does it really apply to? Commercial industries, government agencies, and other international sources might have available data similar to what you are looking for. In general, internal and external technical reports and data based on similar and dissimilar equipment is often the first and only place checked. A common philosophy is "I have a number - that is good enough". But, is it? Have you ever considered the difference in reported data from various federal datasets and technical reports when compared to similar sources from national and/or international datasets? Just how well does your data compare? Understanding how the reported data was derived, and interpreting the information and details associated with the data is as important as the data itself.

  10. Quality assurance and reliability

    International Nuclear Information System (INIS)

    Normand, J.; Charon, M.

    1975-01-01

    Concern for obtaining high-quality products which will function properly when required to do so is nothing new - it is one manifestation of a conscientious attitude to work. However, the complexity and cost of equipment and the consequences of even temporary immobilization are such that it has become necessary to make special arrangements for obtaining high-quality products and examining what one has obtained. Each unit within an enterprise must examine its own work or arrange for it to be examined; a unit whose specific task is quality assurance is responsible for overall checking, but does not relieve other units of their responsibility. Quality assurance is a form of mutual assistance within an enterprise, designed to remove the causes of faults as far as possible. It begins very early in a project and continues through the ordering stage, construction, start-up trials and operation. Quality and hence reliability are the direct result of what is done at all stages of a project. They depend on constant attention to detail, for even a minor piece of poor workmanship can, in the case of an essential item of equipment, give rise to serious operational difficulties

  11. Estimation of aqueous solubility of TODGA using group contribution method

    International Nuclear Information System (INIS)

    Balasubramonian, S.; Kumar, Shekhar; Sampath, M.; Sivakumar, D.; Kamachi Mudali, U.

    2017-01-01

    The aqueous solubility of N, N, N', N'-tetraoctyl-3-oxapentanediamide normally referred as TODGA is experimentally measured. The aqueous solubility was also predicted using Marrero and Gani group contribution method. The modification of original Marrero and Gani method was proposed to accurately predict TODGA solubility. The predicted solubility of TODGA using original Marrero and Gani method, Modified Marrero and Gani method and UNIFAC Model was compared. The predicted solubility of TODGA using modified Marrero and Gani method is 0.0237 g/l against the experimentally measured value of 0.0226 g/l. (author)

  12. Study of solubility of some metal cyclohexane carbonates

    International Nuclear Information System (INIS)

    Niyazov, A.N.; Amanov, K.B.; Trapeznikova, V.F.; Kul'maksimov, A.; Kolosova, N.

    1978-01-01

    The solubility of calcium, magnesium, strontium, barium, cabalt, copper and aluminium cyclohexane, carbonates (CHC) in water has been studied at 25 deg C. The salt solubility has been calculated according to the metal ion concentration in saturated solutions. It has been established, that the cobalt and rare earth cyclohexane carbonates are relatively very soluble in water and have solubility products of SP > 1x10 -5 . The solubility of CHC of multivalent metals increases with the decrease of pH values. Each salt has some ''limiting'' pH value of a solution, below which it decomposes completely and can not exist in a solution in the form of solid phase

  13. Comparing monolithic and fused core HPLC columns for fast chromatographic analysis of fat-soluble vitamins.

    Science.gov (United States)

    Kurdi, Said El; Muaileq, Dina Abu; Alhazmi, Hassan A; Bratty, Mohammed Al; Deeb, Sami El

    2017-06-27

    HPLC stationary phases of monolithic and fused core type can be used to achieve fast chromatographic separation as an alternative to UPLC. In this study, monolithic and fused core stationary phases are compared for fast separation of four fat-soluble vitamins. Three new methods on the first and second generation monolithic silica RP-18e columns and a fused core pentafluoro-phenyl propyl column were developed. Application of three fused core columns offered comparable separations of retinyl palmitate, DL-α-tocopheryl acetate, cholecalciferol and menadione in terms of elution speed and separation efficiency. Separation was achieved in approx. 5 min with good resolution (Rs > 5) and precision (RSD ≤ 0.6 %). Monolithic columns showed, however, a higher number of theoretical plates, better precision and lower column backpressure than the fused core column. The three developed methods were successfully applied to separate and quantitate fat-soluble vitamins in commercial products.

  14. Comparing monolithic and fused core HPLC columns for fast chromatographic analysis of fat-soluble vitamins

    Directory of Open Access Journals (Sweden)

    Kurdi Said El

    2017-06-01

    Full Text Available HPLC stationary phases of monolithic and fused core type can be used to achieve fast chromatographic separation as an alternative to UPLC. In this study, monolithic and fused core stationary phases are compared for fast separation of four fat-soluble vitamins. Three new methods on the first and second generation monolithic silica RP-18e columns and a fused core pentafluoro-phenyl propyl column were developed. Application of three fused core columns offered comparable separations of retinyl palmitate, DL-α-tocopheryl acetate, cholecalciferol and menadione in terms of elution speed and separation efficiency. Separation was achieved in approx. 5 min with good resolution (Rs > 5 and precision (RSD ≤ 0.6 %. Monolithic columns showed, however, a higher number of theoretical plates, better precision and lower column backpressure than the fused core column. The three developed methods were successfully applied to separate and quantitate fat-soluble vitamins in commercial products.

  15. Determination of fat- and water-soluble vitamins by supercritical fluid chromatography: A review.

    Science.gov (United States)

    Tyśkiewicz, Katarzyna; Dębczak, Agnieszka; Gieysztor, Roman; Szymczak, Tomasz; Rój, Edward

    2018-01-01

    Vitamins are compounds that take part in all basic functions of an organism but also are subject of number of studies performed by different researchers. Two groups of vitamins are distinguished taking into consideration their solubility. Chromatography with supercritical CO 2 has found application in the determination, separation, and quantitative analyses of both fat- and water-soluble vitamins. The methods of vitamins separation have developed and improved throughout the years. Both groups of compounds were separated using supercritical fluid chromatography with different detection on different stationary phases. The main aim of this review is to provide an overview of the studies of vitamins separation that have been determined so far. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Design of Chemical Literacy Assessment by Using Model of Educational Reconstruction (MER) on Solubility Topic

    Science.gov (United States)

    Yusmaita, E.; Nasra, Edi

    2018-04-01

    This research aims to produce instrument for measuring chemical literacy assessment in basic chemistry courses with solubility topic. The construction of this measuring instrument is adapted to the PISA (Programme for International Student Assessment) problem’s characteristics and the Syllaby of Basic Chemistry in KKNI-IndonesianNational Qualification Framework. The PISA is a cross-country study conducted periodically to monitor the outcomes of learners' achievement in each participating country. So far, studies conducted by PISA include reading literacy, mathematic literacy and scientific literacy. Refered to the scientific competence of the PISA study on science literacy, an assessment designed to measure the chemical literacy of the chemistry department’s students in UNP. The research model used is MER (Model of Educational Reconstruction). The validity and reliability values of discourse questions is measured using the software ANATES. Based on the acquisition of these values is obtained a valid and reliable chemical literacy questions.There are seven question items limited response on the topic of solubility with valid category, the acquisition value of test reliability is 0,86, and has a difficulty index and distinguishing good

  17. Reliability of Oronasal Fistula Classification.

    Science.gov (United States)

    Sitzman, Thomas J; Allori, Alexander C; Matic, Damir B; Beals, Stephen P; Fisher, David M; Samson, Thomas D; Marcus, Jeffrey R; Tse, Raymond W

    2018-01-01

    Objective Oronasal fistula is an important complication of cleft palate repair that is frequently used to evaluate surgical quality, yet reliability of fistula classification has never been examined. The objective of this study was to determine the reliability of oronasal fistula classification both within individual surgeons and between multiple surgeons. Design Using intraoral photographs of children with repaired cleft palate, surgeons rated the location of palatal fistulae using the Pittsburgh Fistula Classification System. Intrarater and interrater reliability scores were calculated for each region of the palate. Participants Eight cleft surgeons rated photographs obtained from 29 children. Results Within individual surgeons reliability for each region of the Pittsburgh classification ranged from moderate to almost perfect (κ = .60-.96). By contrast, reliability between surgeons was lower, ranging from fair to substantial (κ = .23-.70). Between-surgeon reliability was lowest for the junction of the soft and hard palates (κ = .23). Within-surgeon and between-surgeon reliability were almost perfect for the more general classification of fistula in the secondary palate (κ = .95 and κ = .83, respectively). Conclusions This is the first reliability study of fistula classification. We show that the Pittsburgh Fistula Classification System is reliable when used by an individual surgeon, but less reliable when used among multiple surgeons. Comparisons of fistula occurrence among surgeons may be subject to less bias if they use the more general classification of "presence or absence of fistula of the secondary palate" rather than the Pittsburgh Fistula Classification System.

  18. Dependent systems reliability estimation by structural reliability approach

    DEFF Research Database (Denmark)

    Kostandyan, Erik; Sørensen, John Dalsgaard

    2014-01-01

    Estimation of system reliability by classical system reliability methods generally assumes that the components are statistically independent, thus limiting its applicability in many practical situations. A method is proposed for estimation of the system reliability with dependent components, where...... the leading failure mechanism(s) is described by physics of failure model(s). The proposed method is based on structural reliability techniques and accounts for both statistical and failure effect correlations. It is assumed that failure of any component is due to increasing damage (fatigue phenomena...... identification. Application of the proposed method can be found in many real world systems....

  19. Micelles from lipid derivatives of water-soluble polymers as delivery systems for poorly soluble drugs.

    Science.gov (United States)

    Lukyanov, Anatoly N; Torchilin, Vladimir P

    2004-05-07

    Polymeric micelles have a whole set of unique characteristics, which make them very promising drug carriers, in particular, for poorly soluble drugs. Our review article focuses on micelles prepared from conjugates of water-soluble polymers, such as polyethylene glycol (PEG) or polyvinyl pyrrolidone (PVP), with phospholipids or long-chain fatty acids. The preparation of micelles from certain polymer-lipid conjugates and the loading of these micelles with various poorly soluble anticancer agents are discussed. The data on the characterization of micellar preparations in terms of their morphology, stability, longevity in circulation, and ability to spontaneously accumulate in experimental tumors via the enhanced permeability and retention (EPR) effect are presented. The review also considers the preparation of targeted immunomicelles with specific antibodies attached to their surface. Available in vivo results on the efficiency of anticancer drugs incorporated into plain micelles and immunomicelles in animal models are also discussed.

  20. Overcoming the solubility limit with solubility-enhancement tags: successful applications in biomolecular NMR studies

    International Nuclear Information System (INIS)

    Zhou Pei; Wagner, Gerhard

    2010-01-01

    Although the rapid progress of NMR technology has significantly expanded the range of NMR-trackable systems, preparation of NMR-suitable samples that are highly soluble and stable remains a bottleneck for studies of many biological systems. The application of solubility-enhancement tags (SETs) has been highly effective in overcoming solubility and sample stability issues and has enabled structural studies of important biological systems previously deemed unapproachable by solution NMR techniques. In this review, we provide a brief survey of the development and successful applications of the SET strategy in biomolecular NMR. We also comment on the criteria for choosing optimal SETs, such as for differently charged target proteins, and recent new developments on NMR-invisible SETs.

  1. Diagnosing solubility limitations – the example of hydrate formation

    Directory of Open Access Journals (Sweden)

    Joerg Berghausen

    2014-07-01

    Full Text Available Solubility is regarded as one of the key challenges in many drug discovery projects. Thus, it’s essential to support the lead finding and optimization efforts by appropriate solubility data. In silico solubility prediction remains challenging and therefore a screening assay is used as a first filter, followed by selected follow-up assays to reveal what causes the low solubility of a specific compound or chemotype. Results from diagnosing the underlying reason for solubility limitation are discussed. As lipophilicity and crystal lattice forces are regarded as main contributors to limiting solubility, changes in solid state are important to be recognized. Solubility limitation by various factors will be presented and the impact of the solid-state is exemplified by compounds that are able to form hydrates.

  2. Characterization of Soluble Organics in Produced Water

    Energy Technology Data Exchange (ETDEWEB)

    Bostick, D.T.

    2002-01-16

    Soluble organics in produced water and refinery effluents represent treatment problems for the petroleum industry. Neither the chemistry involved in the production of soluble organics nor the impact of these chemicals on total effluent toxicity is well understood. The U.S. Department of Energy provides funding for Oak Ridge National Laboratory (ORNL) to support a collaborative project with Shell, Chevron, Phillips, and Statoil entitled ''Petroleum and Environmental Research Forum project (PERF 9844: Manage Water-Soluble Organics in Produced Water''). The goal of this project, which involves characterization and evaluation of these water-soluble compounds, is aimed at reducing the future production of such contaminants. To determine the effect that various drilling conditions might have on water-soluble organics (WSO) content in produced water, a simulated brine water containing the principal inorganic components normally found in Gulf of Mexico (GOM) brine sources was prepared. The GOM simulant was then contacted with as-received crude oil from a deep well site to study the effects of water cut, produced-water pH, salinity, pressure, temperature, and crude oil sources on the type and content of the WSO in produced water. The identities of individual semivolatile organic compounds (SVOCs) were determined in all as-received crude and actual produced water samples using standard USEPA Method (8270C) protocol. These analyses were supplemented with the more general measurements of total petroleum hydrocarbon (TPH) content in the gas (C{sub 6}-C{sub 10}), diesel (C{sub 10}-C{sub 20}), and oil (C{sub 20}-C{sub 28}) carbon ranges as determined by both gas chromatographic (GC) and infrared (IR) analyses. An open liquid chromatographic procedure was also used to differentiate the saturated hydrocarbon, aromatic hydrocarbon, and polar components within the extractable TPH. Inorganic constituents in the produced water were analyzed by ion

  3. Novel electrosprayed nanospherules for enhanced aqueous solubility and oral bioavailability of poorly water-soluble fenofibrate

    Directory of Open Access Journals (Sweden)

    Yousaf AM

    2016-01-01

    Full Text Available Abid Mehmood Yousaf,1,2 Omer Mustapha,1 Dong Wuk Kim,1 Dong Shik Kim,1 Kyeong Soo Kim,1 Sung Giu Jin,1 Chul Soon Yong,3 Yu Seok Youn,4 Yu-Kyoung Oh,5 Jong Oh Kim,3 Han-Gon Choi1 1College of Pharmacy and Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan, Gyeonggi, South Korea; 2Faculty of Pharmacy, University of Central Punjab, Johar, Lahore, Pakistan; 3College of Pharmacy, Yeungnam University, Gyongsan, North Gyeongsang, 4School of Pharmacy, Sungkyunkwan University, Suwon, Gyeonggi, 5College of Pharmacy, Seoul National University, Seoul, South Korea Purpose: The purpose of the present research was to develop a novel electrosprayed nanospherule providing the most optimized aqueous solubility and oral bioavailability for poorly water-soluble fenofibrate.Methods: Numerous fenofibrate-loaded electrosprayed nanospherules were prepared with polyvinylpyrrolidone (PVP and Labrafil® M 2125 as carriers using the electrospray technique, and the effect of the carriers on drug solubility and solvation was assessed. The solid state characterization of an optimized formulation was conducted by scanning electron microscopy, powder X-ray diffraction, differential scanning calorimetry, and Fourier transform infrared spectroscopic analyses. Oral bioavailability in rats was also evaluated for the formulation of an optimized nanospherule in comparison with free drug and a conventional fenofibrate-loaded solid dispersion.Results: All of the electrosprayed nanospherule formulations had remarkably enhanced aqueous solubility and dissolution compared with free drug. Moreover, Labrafil M 2125, a surfactant, had a positive influence on the solubility and dissolution of the drug in the electrosprayed nanospherule. Increases were observed as the PVP/drug ratio increased to 4:1, but higher ratios gave no significant increases. In particular, an electrosprayed nanospherule composed of fenofibrate, PVP, and Labrafil M 2125 at the weight ratio of 1

  4. Radioimmunological determination of soluble immune complexes

    Energy Technology Data Exchange (ETDEWEB)

    Falck, P; Meffert, H; Diezel, W; Schmidt, E; Soennichsen, N [Humboldt-Universitaet, Berlin (German Democratic Republic). Bereich Medizin (Charite)

    1979-04-01

    Soluble immune complexes were determined in sera from patients with systemic lupus erythematosus, using /sup 125/I-labelled anti-Ig-antibody and plastics-fixed C1q (component of complement). The detection limit of the method is 0.1 ..mu..g of aggregated human IgG and the range is between 0.1 ..mu..g and 10 ..mu..g per 0.5 ml serum. In 58% of the sera tested an increase of the number of immune complexes was found.

  5. Reliability of reactor materials

    International Nuclear Information System (INIS)

    Toerroenen, K.; Aho-Mantila, I.

    1986-05-01

    This report is the final technical report of the fracture mechanics part of the Reliability of Reactor Materials Programme, which was carried out at the Technical Research Centre of Finland (VTT) through the years 1981 to 1983. Research and development work was carried out in five major areas, viz. statistical treatment and modelling of cleavage fracture, crack arrest, ductile fracture, instrumented impact testing as well as comparison of numerical and experimental elastic-plastic fracture mechanics. In the area of cleavage fracture the critical variables affecting the fracture of steels are considered in the frames of a statistical model, so called WST-model. Comparison of fracture toughness values predicted by the model and corresponding experimental values shows excellent agreement for a variety of microstructures. different posibilities for using the model are discussed. The development work in the area of crack arrest testing was concentrated in the crack starter properties, test arrangement and computer control. A computerized elastic-plastic fracture testing method with a variety of test specimen geometries in a large temperature range was developed for a routine stage. Ductile fracture characteristics of reactor pressure vessel steel A533B and comparable weld material are given. The features of a new, patented instrumented impact tester are described. Experimental and theoretical comparisons between the new and conventional testers indicated clearly the improvements achieved with the new tester. A comparison of numerical and experimental elastic-plastic fracture mechanics capabilities at VTT was carried out. The comparison consisted of two-dimensional linear elastic as well as elastic-plastic finite element analysis of four specimen geometries and equivalent experimental tests. (author)

  6. Field reliability of electronic systems

    International Nuclear Information System (INIS)

    Elm, T.

    1984-02-01

    This report investigates, through several examples from the field, the reliability of electronic units in a broader sense. That is, it treats not just random parts failure, but also inadequate reliability design and (externally and internally) induced failures. The report is not meant to be merely an indication of the state of the art for the reliability prediction methods we know, but also as a contribution to the investigation of man-machine interplay in the operation and repair of electronic equipment. The report firmly links electronics reliability to safety and risk analyses approaches with a broader, system oriented view of reliability prediction and with postfailure stress analysis. It is intended to reveal, in a qualitative manner, the existence of symptom and cause patterns. It provides a background for further investigations to identify the detailed mechanisms of the faults and the remedical actions and precautions for achieving cost effective reliability. (author)

  7. Reliability Assessment Of Wind Turbines

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard

    2014-01-01

    Reduction of cost of energy for wind turbines are very important in order to make wind energy competitive compared to other energy sources. Therefore the turbine components should be designed to have sufficient reliability but also not be too costly (and safe). This paper presents models...... for uncertainty modeling and reliability assessment of especially the structural components such as tower, blades, substructure and foundation. But since the function of a wind turbine is highly dependent on many electrical and mechanical components as well as a control system also reliability aspects...... of these components are discussed and it is described how there reliability influences the reliability of the structural components. Two illustrative examples are presented considering uncertainty modeling, reliability assessment and calibration of partial safety factors for structural wind turbine components exposed...

  8. Reliability engineering theory and practice

    CERN Document Server

    Birolini, Alessandro

    2014-01-01

    This book shows how to build in, evaluate, and demonstrate reliability and availability of components, equipment, systems. It presents the state-of-theart of reliability engineering, both in theory and practice, and is based on the author's more than 30 years experience in this field, half in industry and half as Professor of Reliability Engineering at the ETH, Zurich. The structure of the book allows rapid access to practical results. This final edition extend and replace all previous editions. New are, in particular, a strategy to mitigate incomplete coverage, a comprehensive introduction to human reliability with design guidelines and new models, and a refinement of reliability allocation, design guidelines for maintainability, and concepts related to regenerative stochastic processes. The set of problems for homework has been extended. Methods & tools are given in a way that they can be tailored to cover different reliability requirement levels and be used for safety analysis. Because of the Appendice...

  9. Reliability of Wireless Sensor Networks

    Science.gov (United States)

    Dâmaso, Antônio; Rosa, Nelson; Maciel, Paulo

    2014-01-01

    Wireless Sensor Networks (WSNs) consist of hundreds or thousands of sensor nodes with limited processing, storage, and battery capabilities. There are several strategies to reduce the power consumption of WSN nodes (by increasing the network lifetime) and increase the reliability of the network (by improving the WSN Quality of Service). However, there is an inherent conflict between power consumption and reliability: an increase in reliability usually leads to an increase in power consumption. For example, routing algorithms can send the same packet though different paths (multipath strategy), which it is important for reliability, but they significantly increase the WSN power consumption. In this context, this paper proposes a model for evaluating the reliability of WSNs considering the battery level as a key factor. Moreover, this model is based on routing algorithms used by WSNs. In order to evaluate the proposed models, three scenarios were considered to show the impact of the power consumption on the reliability of WSNs. PMID:25157553

  10. The value of service reliability

    OpenAIRE

    Benezech , Vincent; Coulombel , Nicolas

    2013-01-01

    International audience; This paper studies the impact of service frequency and reliability on the choice of departure time and the travel cost of transit users. When the user has (α, β, γ) scheduling preferences, we show that the optimal head start decreases with service reliability, as expected. It does not necessarily decrease with service frequency, however. We derive the value of service headway (VoSH) and the value of service reliability (VoSR), which measure the marginal effect on the e...

  11. Distribution-Independent Reliable Learning

    OpenAIRE

    Kanade, Varun; Thaler, Justin

    2014-01-01

    We study several questions in the reliable agnostic learning framework of Kalai et al. (2009), which captures learning tasks in which one type of error is costlier than others. A positive reliable classifier is one that makes no false positive errors. The goal in the positive reliable agnostic framework is to output a hypothesis with the following properties: (i) its false positive error rate is at most $\\epsilon$, (ii) its false negative error rate is at most $\\epsilon$ more than that of the...

  12. Thermodynamic Stability Analysis of Tolbutamide Polymorphs and Solubility in Organic Solvents.

    Science.gov (United States)

    Svärd, Michael; Valavi, Masood; Khamar, Dikshitkumar; Kuhs, Manuel; Rasmuson, Åke C

    2016-06-01

    Melting temperatures and enthalpies of fusion have been determined by differential scanning calorimetry (DSC) for 2 polymorphs of the drug tolbutamide: FI(H) and FV. Heat capacities have been determined by temperature-modulated DSC for 4 polymorphs: FI(L), FI(H), FII, FV, and for the supercooled melt. The enthalpy of fusion of FII at its melting point has been estimated from the enthalpy of transition of FII into FI(H) through a thermodynamic cycle. Calorimetric data have been used to derive a quantitative polymorphic stability relationship between these 4 polymorphs, showing that FII is the stable polymorph below approximately 333 K, above which temperature FI(H) is the stable form up to its melting point. The relative stability of FV is well below the other polymorphs. The previously reported kinetic reversibility of the transformation between FI(L) and FI(H) has been verified using in situ Raman spectroscopy. The solid-liquid solubility of FII has been gravimetrically determined in 5 pure organic solvents (methanol, 1-propanol, ethyl acetate, acetonitrile, and toluene) over the temperature range 278 to 323 K. The ideal solubility has been estimated from calorimetric data, and solution activity coefficients at saturation in the 5 solvents determined. All solutions show positive deviation from Raoult's law, and all van't Hoff plots of solubility data are nonlinear. The solubility in toluene is well below that observed in the other investigated solvents. Solubility data have been correlated and extrapolated to the melting point using a semiempirical regression model. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  13. Reliability analysis of digital based I and C system

    Energy Technology Data Exchange (ETDEWEB)

    Kang, I. S.; Cho, B. S.; Choi, M. J. [KOPEC, Yongin (Korea, Republic of)

    1999-10-01

    Rapidly, digital technology is being widely applied in replacing analog component installed in existing plant and designing new nuclear power plant for control and monitoring system in Korea as well as in foreign countries. Even though many merits of digital technology, it is being faced with a new problem of reliability assurance. The studies for solving this problem are being performed vigorously in foreign countries. The reliability of KNGR Engineered Safety Features Component Control System (ESF-CCS), digital based I and C system, was analyzed to verify fulfillment of the ALWR EPRI-URD requirement for reliability analysis and eliminate hazards in design applied new technology. The qualitative analysis using FMEA and quantitative analysis using reliability block diagram were performed. The results of analyses are shown in this paper.

  14. OREDA offshore and onshore reliability data volume 1 - topside equipment

    CERN Document Server

    OREDA

    2015-01-01

    This handbook presents high quality reliability data for offshore equipment collected during phase VI to IX (project period 2000 – 2009) of the OREDA project. The intention of the handbook is to provide both quantitative and qualitative information as a basis for Performance Forecasting or RAMS (Reliability, Availability, Maintainability and Safety) analyses. Volume 1 is about Topside Equipment. Compared to earlier editions, there are only minor changes in the reliability data presentation. To obtain a reasonable population for presenting reliability data for topside equipment in the 2015 edition, some data from phases VI and VII already issued in the previous 2009 handbook (5th edition) have also been included. The 2015 topside volume is divided into two parts. Part I describes the OREDA project, different data collection phases and the estimation procedures used to generate the data tables presented in Part II of the handbook. Topside data are in general not covering the whole lifetime of equipment, but ...

  15. RTE - 2015 Reliability Report. Summary

    International Nuclear Information System (INIS)

    2016-01-01

    Every year, RTE produces a reliability report for the past year. This report includes a number of results from previous years so that year-to-year comparisons can be drawn and long-term trends analysed. The 2015 report underlines the major factors that have impacted on the reliability of the electrical power system, without focusing exclusively on Significant System Events (ESS). It describes various factors which contribute to present and future reliability and the numerous actions implemented by RTE to ensure reliability today and in the future, as well as the ways in which the various parties involved in the electrical power system interact across the whole European interconnected network

  16. Evaluated and estimated solubility of some elements for performance assessment of geological disposal of high-level radioactive waste using updated version of thermodynamic database

    International Nuclear Information System (INIS)

    Kitamura, Akira; Doi, Reisuke; Yoshida, Yasushi

    2011-01-01

    Japan Atomic Energy Agency (JAEA) established the thermodynamic database (JAEA-TDB) for performance assessment of geological disposal of high-level radioactive waste (HLW) and TRU waste. Twenty-five elements which were important for the performance assessment of geological disposal were selected for the database. JAEA-TDB enhanced reliability of evaluation and estimation of their solubility through selecting the latest and the most reliable thermodynamic data at present. We evaluated and estimated solubility of the 25 elements in the simulated porewaters established in the 'Second Progress Report for Safety Assessment of Geological Disposal of HLW in Japan' using the JAEA-TDB and compared with those using the previous thermodynamic database (JNC-TDB). It was found that most of the evaluated and estimated solubility values were not changed drastically, but the solubility and speciation of dominant aqueous species for some elements using the JAEA-TDB were different from those using the JNC-TDB. We discussed about how to provide reliable solubility values for the performance assessment. (author)

  17. Near Infrared Spectral Linearisation in Quantifying Soluble Solids Content of Intact Carambola

    Directory of Open Access Journals (Sweden)

    Mohd Zubir MatJafri

    2013-04-01

    Full Text Available This study presents a novel application of near infrared (NIR spectral linearisation for measuring the soluble solids content (SSC of carambola fruits. NIR spectra were measured using reflectance and interactance methods. In this study, only the interactance measurement technique successfully generated a reliable measurement result with a coefficient of determination of (R2 = 0.724 and a root mean square error of prediction for (RMSEP = 0.461° Brix. The results from this technique produced a highly accurate and stable prediction model compared with multiple linear regression techniques.

  18. Near infrared spectral linearisation in quantifying soluble solids content of intact carambola.

    Science.gov (United States)

    Omar, Ahmad Fairuz; MatJafri, Mohd Zubir

    2013-04-12

    This study presents a novel application of near infrared (NIR) spectral linearisation for measuring the soluble solids content (SSC) of carambola fruits. NIR spectra were measured using reflectance and interactance methods. In this study, only the interactance measurement technique successfully generated a reliable measurement result with a coefficient of determination of (R2) = 0.724 and a root mean square error of prediction for (RMSEP) = 0.461° Brix. The results from this technique produced a highly accurate and stable prediction model compared with multiple linear regression techniques.

  19. Solubility of xenon in liquid sodium

    International Nuclear Information System (INIS)

    Veleckis, E.; Cafasso, F.A.; Feder, H.M.

    1976-01-01

    The solubility of xenon in liquid sodium was measured as a function of pressure (2-8 atm) and temperature (350-600 0 C). Henry's law was obeyed with the value of the Henry's law constant, K/sub H/ = N/sub Xe//P, ranging from 1.38 x 10 -10 atm -1 at 350C, to 1.59 x 10 -8 atm -1 at 600 0 C where N/sub Xe/ and P are the atom fraction and the partial pressure of xenon, respectively. The temperature dependence of solubility may be represented by log 10 lambda = (0.663 +- 0.01) - (4500 +- 73) T -1 , where lambda is the Ostwald coefficient (the volume of xenon dissolved per unit volume of sodium at the temperature of the experiment). The heat of solution of xenon in sodium was 20.6 +- 0.7 kcal/mole, where the standard state of xenon is defined as that of 1 mole of an ideal gas, confined to a volume equal to the molar volume of sodium

  20. Solubility and bioavailability improvement of pazopanib hydrochloride.

    Science.gov (United States)

    Herbrink, Maikel; Groenland, Stefanie L; Huitema, Alwin D R; Schellens, Jan H M; Beijnen, Jos H; Steeghs, Neeltje; Nuijen, Bastiaan

    2018-06-10

    The anti-cancer drug pazopanib hydrochloride (PZH) has a very low aqueous solubility and a variable oral bioavailability. A new pharmaceutical formulation with an improved solubility may enhance the bioavailability and reduce the variability. A broad selection of polymer excipients was tested for their compatibility and solubilizing properties by conventional microscopic, thermal and spectrometric techniques. A wet milling and mixing technique was used to produce homogenous powder mixtures. The dissolution properties of the formulation were tested by a pH-switch dissolution model. The final formulation was tested in vivo in cancer patient following a dose escalation design. Of the tested mixture formulations, the one containing the co-block polymer Soluplus® in a 8:1 ratio with PZH performed best in terms of in vitro dissolution properties. The in vivo results indicated that 300 mg of the developed formulation yields similar exposure and a lower variability (379 μg/mL∗h (36.7% CV)) than previously reported values for the standard PZH formulation (Votrient®) at the approved dose of 800 mg. Furthermore, the expected plasma-C through levels (27.2 μg/mL) exceeds the defined therapeutic efficacy threshold of 20 μg/mL. Copyright © 2018 Elsevier B.V. All rights reserved.