WorldWideScience

Sample records for reliable performance criteria

  1. Safety and reliability criteria

    International Nuclear Information System (INIS)

    O'Neil, R.

    1978-01-01

    Nuclear power plants and, in particular, reactor pressure boundary components have unique reliability requirements, in that usually no significant redundancy is possible, and a single failure can give rise to possible widespread core damage and fission product release. Reliability may be required for availability or safety reasons, but in the case of the pressure boundary and certain other systems safety may dominate. Possible Safety and Reliability (S and R) criteria are proposed which would produce acceptable reactor design. Without some S and R requirement the designer has no way of knowing how far he must go in analysing his system or component, or whether his proposed solution is likely to gain acceptance. The paper shows how reliability targets for given components and systems can be individually considered against the derived S and R criteria at the design and construction stage. Since in the case of nuclear pressure boundary components there is often very little direct experience on which to base reliability studies, relevant non-nuclear experience is examined. (author)

  2. Wind turbine performance: Methods and criteria for reliability of measured power curves

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, D.A. [Advanced Wind Turbines Inc., Seattle, WA (United States)

    1996-12-31

    In order to evaluate the performance of prototype turbines, and to quantify incremental changes in performance through field testing, Advanced Wind Turbines (AWT) has been developing methods and requirements for power curve measurement. In this paper, field test data is used to illustrate several issues and trends which have resulted from this work. Averaging and binning processes, data hours per wind-speed bin, wind turbulence levels, and anemometry methods are all shown to have significant impacts on the resulting power curves. Criteria are given by which the AWT power curves show a high degree of repeatability, and these criteria are compared and contrasted with current published standards for power curve measurement. 6 refs., 5 figs., 5 tabs.

  3. Reliability criteria for voltage stability

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Carson W; Silverstein, Brian L [Bonneville Power Administration, Portland, OR (United States)

    1994-12-31

    In face of costs pressures, there is need to allocate scare resources more effectively in order to achieve voltage stability. This naturally leads to development of probabilistic criteria and notions of rick management. In this paper it is presented a discussion about criteria for long term voltage stability limited to the case in which the time frames are topically several minutes. (author) 14 refs., 1 fig.

  4. Reliability criteria selection for integrated resource planning

    International Nuclear Information System (INIS)

    Ruiu, D.; Ye, C.; Billinton, R.; Lakhanpal, D.

    1993-01-01

    A study was conducted on the selection of a generating system reliability criterion that ensures a reasonable continuity of supply while minimizing the total costs to utility customers. The study was conducted using the Institute for Electronic and Electrical Engineers (IEEE) reliability test system as the study system. The study inputs and results for conditions and load forecast data, new supply resources data, demand-side management resource data, resource planning criterion, criterion value selection, supply side development, integrated resource development, and best criterion values, are tabulated and discussed. Preliminary conclusions are drawn as follows. In the case of integrated resource planning, the selection of the best value for a given type of reliability criterion can be done using methods similar to those used for supply side planning. The reliability criteria values previously used for supply side planning may not be economically justified when integrated resource planning is used. Utilities may have to revise and adopt new, and perhaps lower supply reliability criteria for integrated resource planning. More complex reliability criteria, such as energy related indices, which take into account the magnitude, frequency and duration of the expected interruptions are better adapted than the simpler capacity-based reliability criteria such as loss of load expectation. 7 refs., 5 figs., 10 tabs

  5. Reliability Criteria for Thick Bonding Wire.

    Science.gov (United States)

    Dagdelen, Turker; Abdel-Rahman, Eihab; Yavuz, Mustafa

    2018-04-17

    Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire.

  6. Reliability Criteria for Thick Bonding Wire

    Directory of Open Access Journals (Sweden)

    Turker Dagdelen

    2018-04-01

    Full Text Available Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al and aluminum coated copper (CucorAl wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire.

  7. Reliability Criteria for Thick Bonding Wire

    Science.gov (United States)

    Yavuz, Mustafa

    2018-01-01

    Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire. PMID:29673194

  8. Evaluation criteria of structural steel reliability

    International Nuclear Information System (INIS)

    Zav'yalov, A.S.

    1980-01-01

    Different low-carbon and medium-carbon structural steels are investigated. It is stated that steel reliability evaluation criteria depend on the fracture mode, steel suffering from the brittle fracture under the influence of the stresses (despite their great variety) arising in articles during the production and operation. Fibrous steel fracture at the given temperature and article thickness says about its high ductility and toughness and brittle fractures are impossible. Brittle fractures take place in case of a crystalline and mixed fracture with a predominant crystalline component. Evaluation methods of article and sample steel structural strength differing greatly from real articles in a thickness (diameter) or used at temperatures higher than possible operation temperatures cannot be reliability evaluation criteria because at a great thickness (diameter) and lower operation temperatures steel fracture and its strain mode can change resulting in a sharp reliability degradation

  9. Criteria for performance evaluation

    Directory of Open Access Journals (Sweden)

    David J. Weiss

    2009-03-01

    Full Text Available Using a cognitive task (mental calculation and a perceptual-motor task (stylized golf putting, we examined differential proficiency using the CWS index and several other quantitative measures of performance. The CWS index (Weiss and Shanteau, 2003 is a coherence criterion that looks only at internal properties of the data without incorporating an external standard. In Experiment 1, college students (n = 20 carried out 2- and 3-digit addition and multiplication problems under time pressure. In Experiment 2, experienced golfers (n = 12, also college students, putted toward a target from nine different locations. Within each experiment, we analyzed the same responses using different methods. For the arithmetic tasks, accuracy information (mean absolute deviation from the correct answer, MAD using a coherence criterion was available; for golf, accuracy information using a correspondence criterion (mean deviation from the target, also MAD was available. We ranked the performances of the participants according to each measure, then compared the orders using Spearman's rextsubscript{s}. For mental calculation, the CWS order correlated moderately (rextsubscript{s} =.46 with that of MAD. However, a different coherence criterion, degree of model fit, did not correlate with either CWS or accuracy. For putting, the ranking generated by CWS correlated .68 with that generated by MAD. Consensual answers were also available for both experiments, and the rankings they generated correlated highly with those of MAD. The coherence vs. correspondence distinction did not map well onto criteria for performance evaluation.

  10. Nuclear performance and reliability

    International Nuclear Information System (INIS)

    Rothwell, G.

    1993-01-01

    If fewer forced outages are a sign of improved safety, nuclear power plants have become safer and more productive. There has been a significant improvement in nuclear power plant performance, due largely to a decline in the forced outage rate and a dramatic drop in the average number of forced outages per fuel cycle. If fewer forced outages are a sign of improved safety, nuclear power plants have become safer and more productive over time. To encourage further increases in performance, regulatory incentive schemes should reward reactor operators for improved reliability and safety, as well as for improved performance

  11. A comparative study on the reliability criteria determination

    International Nuclear Information System (INIS)

    Jerng, Dong Wook; Ju, Tae Young

    2009-01-01

    There are two methods to determine the reliability criteria for maintenance effectiveness monitoring; using the failure probability, and the importance from PRA. Comparisons of the results from these two methods provides an insight on the relevancy of setting the reliability criteria to improve the maintenance effectiveness. (author)

  12. Efficiency criteria for high reliability measured system structures

    International Nuclear Information System (INIS)

    Sal'nikov, N.L.

    2012-01-01

    The procedures of structural redundancy are usually used to develop high reliability measured systems. To estimate efficiency of such structures the criteria to compare different systems has been developed. So it is possible to develop more exact system by inspection of redundant system data unit stochastic characteristics in accordance with the developed criteria [ru

  13. Performance objectives and criteria for plant evaluations

    International Nuclear Information System (INIS)

    1983-04-01

    Maintenance organization and administration should ensure effective implementation and control of maintenance activities. The criteria are: A. The organizational structure is clearly defined. B. Staffing and resources are sufficient to accomplish assigned tasks. C. Responsibilities and authority of each management, supervisory, and professional position are clearly defined. D. Personnel clearly understand their authority, responsibilities, accountabilities, and interfaces with supporting groups. E. Administrative controls are employed for maintenance activities important to plant safety and reliability. F. Performance appraisals are effectively utilized to enhance individual performance

  14. Photovoltaic performance and reliability workshop

    Energy Technology Data Exchange (ETDEWEB)

    Mrig, L. [ed.

    1993-12-01

    This workshop was the sixth in a series of workshops sponsored by NREL/DOE under the general subject of photovoltaic testing and reliability during the period 1986--1993. PV performance and PV reliability are at least as important as PV cost, if not more. In the US, PV manufacturers, DOE laboratories, electric utilities, and others are engaged in the photovoltaic reliability research and testing. This group of researchers and others interested in the field were brought together to exchange the technical knowledge and field experience as related to current information in this evolving field of PV reliability. The papers presented here reflect this effort since the last workshop held in September, 1992. The topics covered include: cell and module characterization, module and system testing, durability and reliability, system field experience, and standards and codes.

  15. SGHWR fuel performance, safety and reliability

    International Nuclear Information System (INIS)

    Pickman, D.O.; Inglis, G.H.

    1977-05-01

    The design principles involved in fuel pins and elements need to take account of the sometimes conflicting requirements of safety and reliability. The principal factors involved in this optimisation are discussed and it is shown from fuel irradiation experience in the Winfrith SGHWR that the necessary bias towards safety has not resulted in a reliability level lower than that shown by other successful water reactor designs. Reliability has important economic implications. By a detailed evaluation of SGHWR fuel defects it is shown that very few defects can be shown to be related to design, rating, or burn-up. This demonstrates that economic aspects have not over-ridden necessary criteria that most be met to achieve the desirable reliability level. It is possible that large scale experience on SGHWR fuel may eventually demonstrate that the balance is too much in favour of reliability and consideration may be given to whether design changes favouring economy could be achieved without compromising safety. The safety criteria applied to SGHWR fuel are designed to avoid any possibility of a temperature runaway in any credible accident situation. the philosophy and supporting experimental work programme are outlines and the fuel design features which particularly contribute to maximising safety margins are outlined. Reference is made to the new 60-pin fuel element to be used in the commercial SGHWRs and to its comparison in design and performance aspects with the 36-pin element that has been used to date in the Winfrith SGHWR. (author)

  16. SGHWR fuel performance, safety and reliability

    International Nuclear Information System (INIS)

    Pickman, D.O.; Inglis, G.H.

    1977-01-01

    The design principles involved in fuel pins and elements need to take account of the sometimes conflicting requirements of performance, safety and reliability. The principal factors involved in this optimisation are discussed and it is shown from fuel irradiation experience in the Winfrith S.G.H.W.R. that the necessary bias toward safety has not resulted in a reliability level lower than that shown by other successful water reactor designs. Reliability has important economic implications and has to be paid for. By a detailed evaluation of S.G.H.W.R. fuel defects it is shown that very few defects can be shown to be related to design, rating or burn-up. This demonstrates that economic aspects have not over-ridden necessary criteria that must be met to achieve the desirable reliability level. It is possible that large-scale experience with S.G.H.W.R. fuel may eventually demonstrate that the balance is too much in favour of reliability and consideration may be given to whether design changes favouring economy could be achieved without compromising safety. The safety criteria applied to S.G.H.W.R. fuel are designed to avoid any possibility of a temperature runaway in any credible accident situation. The philosophy and supporting experimental work programme are outlined and the fuel design features which particularly contribute to maximising safety margins are outlined. Reference is made to new 60 pin fuel element to be used in the commercial S.G.H.W.R.'s and how it compares in design and performance aspects with the 36 pin element that has been used to date in the Winfrith S.G.H.W.R

  17. Education Criteria for Performance Excellence, 2002.

    Science.gov (United States)

    National Inst. of Standards and Technology, Gaithersburg, MD.

    The education criteria presented in this guide are designed to help organizations use an integrated approach to organizational performance management that results in delivery of ever-improving value to students and stakeholders. Implementation of the criteria will contribute to improvement of education quality, improvement of overall…

  18. Identifying the connective strength between model parameters and performance criteria

    Directory of Open Access Journals (Sweden)

    B. Guse

    2017-11-01

    Full Text Available In hydrological models, parameters are used to represent the time-invariant characteristics of catchments and to capture different aspects of hydrological response. Hence, model parameters need to be identified based on their role in controlling the hydrological behaviour. For the identification of meaningful parameter values, multiple and complementary performance criteria are used that compare modelled and measured discharge time series. The reliability of the identification of hydrologically meaningful model parameter values depends on how distinctly a model parameter can be assigned to one of the performance criteria. To investigate this, we introduce the new concept of connective strength between model parameters and performance criteria. The connective strength assesses the intensity in the interrelationship between model parameters and performance criteria in a bijective way. In our analysis of connective strength, model simulations are carried out based on a latin hypercube sampling. Ten performance criteria including Nash–Sutcliffe efficiency (NSE, Kling–Gupta efficiency (KGE and its three components (alpha, beta and r as well as RSR (the ratio of the root mean square error to the standard deviation for different segments of the flow duration curve (FDC are calculated. With a joint analysis of two regression tree (RT approaches, we derive how a model parameter is connected to different performance criteria. At first, RTs are constructed using each performance criterion as the target variable to detect the most relevant model parameters for each performance criterion. Secondly, RTs are constructed using each parameter as the target variable to detect which performance criteria are impacted by changes in the values of one distinct model parameter. Based on this, appropriate performance criteria are identified for each model parameter. In this study, a high bijective connective strength between model parameters and performance criteria

  19. System Reliability Analysis Considering Correlation of Performances

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Saekyeol; Lee, Tae Hee [Hanyang Univ., Seoul (Korea, Republic of); Lim, Woochul [Mando Corporation, Seongnam (Korea, Republic of)

    2017-04-15

    Reliability analysis of a mechanical system has been developed in order to consider the uncertainties in the product design that may occur from the tolerance of design variables, uncertainties of noise, environmental factors, and material properties. In most of the previous studies, the reliability was calculated independently for each performance of the system. However, the conventional methods cannot consider the correlation between the performances of the system that may lead to a difference between the reliability of the entire system and the reliability of the individual performance. In this paper, the joint probability density function (PDF) of the performances is modeled using a copula which takes into account the correlation between performances of the system. The system reliability is proposed as the integral of joint PDF of performances and is compared with the individual reliability of each performance by mathematical examples and two-bar truss example.

  20. System Reliability Analysis Considering Correlation of Performances

    International Nuclear Information System (INIS)

    Kim, Saekyeol; Lee, Tae Hee; Lim, Woochul

    2017-01-01

    Reliability analysis of a mechanical system has been developed in order to consider the uncertainties in the product design that may occur from the tolerance of design variables, uncertainties of noise, environmental factors, and material properties. In most of the previous studies, the reliability was calculated independently for each performance of the system. However, the conventional methods cannot consider the correlation between the performances of the system that may lead to a difference between the reliability of the entire system and the reliability of the individual performance. In this paper, the joint probability density function (PDF) of the performances is modeled using a copula which takes into account the correlation between performances of the system. The system reliability is proposed as the integral of joint PDF of performances and is compared with the individual reliability of each performance by mathematical examples and two-bar truss example.

  1. TWO CRITERIA FOR GOOD MEASUREMENTS IN RESEARCH: VALIDITY AND RELIABILITY

    Directory of Open Access Journals (Sweden)

    Haradhan Kumar Mohajan

    2017-12-01

    Full Text Available Reliability and validity are two most important and fundamental features in the evaluation of any measurement instrument or toll for a good research. The purpose of this research is to discuss the validity and reliability of measurement instruments that are used in research. Validity concerns what an instrument measures, and how well it does so. Reliability concerns the faith that one can have in the data obtained from use of an instrument, that is, the degree to which any measuring tool controls for random error. An attempt has been taken here to review the reliability and validity, and threat to them in some details.

  2. Interim performance criteria for photovoltaic energy systems. [Glossary included

    Energy Technology Data Exchange (ETDEWEB)

    DeBlasio, R.; Forman, S.; Hogan, S.; Nuss, G.; Post, H.; Ross, R.; Schafft, H.

    1980-12-01

    This document is a response to the Photovoltaic Research, Development, and Demonstration Act of 1978 (P.L. 95-590) which required the generation of performance criteria for photovoltaic energy systems. Since the document is evolutionary and will be updated, the term interim is used. More than 50 experts in the photovoltaic field have contributed in the writing and review of the 179 performance criteria listed in this document. The performance criteria address characteristics of present-day photovoltaic systems that are of interest to manufacturers, government agencies, purchasers, and all others interested in various aspects of photovoltaic system performance and safety. The performance criteria apply to the system as a whole and to its possible subsystems: array, power conditioning, monitor and control, storage, cabling, and power distribution. They are further categorized according to the following performance attributes: electrical, thermal, mechanical/structural, safety, durability/reliability, installation/operation/maintenance, and building/site. Each criterion contains a statement of expected performance (nonprescriptive), a method of evaluation, and a commentary with further information or justification. Over 50 references for background information are also given. A glossary with definitions relevant to photovoltaic systems and a section on test methods are presented in the appendices. Twenty test methods are included to measure performance characteristics of the subsystem elements. These test methods and other parts of the document will be expanded or revised as future experience and needs dictate.

  3. Mobility and reliability performance measurement.

    Science.gov (United States)

    2013-06-01

    This project grew out of the fact that mobility was identified early on as one of the key performance focus areas of NCDOTs : strategic transformation effort. The Transformation Management Team (TMT) established a TMT Mobility Workstream Team : in...

  4. Internet Performance and Reliability Measurements

    International Nuclear Information System (INIS)

    Cottrell, Les

    2003-01-01

    Collaborative HEP research is dependent on good Internet connectivity. Although most local- and wide-area networks are carefully watched, there is little monitoring of connections that cross many networks. This paper describes work in progress at several sites to monitor Internet end-to-end performance between hundreds of HEP sites worldwide. At each collection site, ICMP ping packets are automatically sent periodically to sites of interest. The data is recorded and made available to analysis nodes, which collect the data from multiple collection sites and provide analysis and graphing. Future work includes improving the efficiency and accuracy of ping data collection

  5. Application of STOPP and START criteria: interrater reliability among pharmacists.

    LENUS (Irish Health Repository)

    Ryan, Cristin

    2009-07-01

    Inappropriate prescribing is a well-documented problem in older people. The new screening tools, STOPP (Screening Tool of Older Peoples\\' Prescriptions) and START (Screening Tool to Alert doctors to Right Treatment) have been formulated to identify potentially inappropriate medications (PIMs) and potential errors of omissions (PEOs) in older patients. Consistent, reliable application of STOPP and START is essential for the screening tools to be used effectively by pharmacists.

  6. MHTGR thermal performance envelopes: Reliability by design

    International Nuclear Information System (INIS)

    Etzel, K.T.; Howard, W.W.; Zgliczynski, J.B.

    1992-05-01

    This document discusses thermal performance envelopes which are used to specify steady-state design requirements for the systems of the Modular High Temperature Gas-Cooled Reactor to maximize plant performance reliability with optimized design. The thermal performance envelopes are constructed around the expected operating point accounting for uncertainties in actual plant as-built parameters and plant operation. The components are then designed to perform successfully at all points within the envelope. As a result, plant reliability is maximized by accounting for component thermal performance variation in the design. The design is optimized by providing a means to determine required margins in a disciplined and visible fashion

  7. Delivering high performance BWR fuel reliably

    International Nuclear Information System (INIS)

    Schardt, J.F.

    1998-01-01

    Utilities are under intense pressure to reduce their production costs in order to compete in the increasingly deregulated marketplace. They need fuel, which can deliver high performance to meet demanding operating strategies. GE's latest BWR fuel design, GE14, provides that high performance capability. GE's product introduction process assures that this performance will be delivered reliably, with little risk to the utility. (author)

  8. MEASUREMENT: ACCOUNTING FOR RELIABILITY IN PERFORMANCE ESTIMATES.

    Science.gov (United States)

    Waterman, Brian; Sutter, Robert; Burroughs, Thomas; Dunagan, W Claiborne

    2014-01-01

    When evaluating physician performance measures, physician leaders are faced with the quandary of determining whether departures from expected physician performance measurements represent a true signal or random error. This uncertainty impedes the physician leader's ability and confidence to take appropriate performance improvement actions based on physician performance measurements. Incorporating reliability adjustment into physician performance measurement is a valuable way of reducing the impact of random error in the measurements, such as those caused by small sample sizes. Consequently, the physician executive has more confidence that the results represent true performance and is positioned to make better physician performance improvement decisions. Applying reliability adjustment to physician-level performance data is relatively new. As others have noted previously, it's important to keep in mind that reliability adjustment adds significant complexity to the production, interpretation and utilization of results. Furthermore, the methods explored in this case study only scratch the surface of the range of available Bayesian methods that can be used for reliability adjustment; further study is needed to test and compare these methods in practice and to examine important extensions for handling specialty-specific concerns (e.g., average case volumes, which have been shown to be important in cardiac surgery outcomes). Moreover, it's important to note that the provider group average as a basis for shrinkage is one of several possible choices that could be employed in practice and deserves further exploration in future research. With these caveats, our results demonstrate that incorporating reliability adjustment into physician performance measurements is feasible and can notably reduce the incidence of "real" signals relative to what one would expect to see using more traditional approaches. A physician leader who is interested in catalyzing performance improvement

  9. Delivering high performance BWR fuel reliably

    Energy Technology Data Exchange (ETDEWEB)

    Schardt, J.F. [GE Nuclear Energy, Wilmington, NC (United States)

    1998-07-01

    Utilities are under intense pressure to reduce their production costs in order to compete in the increasingly deregulated marketplace. They need fuel, which can deliver high performance to meet demanding operating strategies. GE's latest BWR fuel design, GE14, provides that high performance capability. GE's product introduction process assures that this performance will be delivered reliably, with little risk to the utility. (author)

  10. Cleanliness criteria to improve steam generator performance

    International Nuclear Information System (INIS)

    Schwarz, T.; Bouecke, R.; Odar, S.

    2005-01-01

    High steam generator performance is a prerequisite for high plant availability and possible life time extension. The major opponent to that is corrosion and fouling of the heating tubes. Such steam generator degradation problems arise from the continuous ingress of non-volatile contaminants, i.e. corrosion products and salt impurities may accumulate in the steam generators. These impurities have their origin in the secondary side systems. The corrosion products generally accumulate in the steam generators and form deposits not only in the flow restricted areas, such as on top of tube sheet and tube support structure, but also build scales on the steam generator heating tubes. In addition, the tube scales in general affect the steam generator thermal performance, which ultimately causes a reduction of power output. The most effective ways of counteracting all these degradation problems, and thus of improving the steam generator performance is to keep them in clean conditions or, if judged necessary, to plan cleaning measures such as mechanical tube sheet lancing or chemical cleaning. This paper presents a methodology how to assess the cleanliness condition of a steam generator by bringing together all available operational and inspection data such as thermal performance and water chemistry data. By means of this all-inclusive approach the cleanliness condition is quantified in terms of a fouling index. The fouling index allows to monitor the condition of a specific steam generator, compare it to other plants and, finally, to serve as criterion for cleaning measures such as chemical cleaning. The application of the cleanliness criteria and the achieved field results with respect to improvements of steam generator performance will be presented. (author)

  11. Models and criteria for waste repository performance

    International Nuclear Information System (INIS)

    Smith, C.F.; Cohen, J.J.

    1981-03-01

    A primary objective of the Waste Management Program is to assure that public health is protected. Predictive modeling, to some extent, will play a role in assuring that this objective is met. This paper considers the requirements and limitations of predictive modeling in providing useful inputs to waste management decision making. Criteria development needs and the relation between criteria and models are also discussed

  12. NWTS program criteria for mined geologic disposal of nuclear wasite: site performance criteria

    International Nuclear Information System (INIS)

    1981-02-01

    This report states ten criteria governing the suitability of sites for mined geologic disposal of high-level radioactive waste. The Department of Energy will use these criteria in its search for sites and will reevaluate their use when the Nuclear Regulatory Commission issues radioactive waste repository rules. These criteria encompass site geometry, geohydrology, geochemistry, geologic characteristics, tectonic environment, human intrusion, surface characteristics, environment, and potential socioeconomic impacts. The contents of this document include background discussion, site performance criteria, and appendices. The background section describes the waste disposal system, the application of the site criteria, and applicable criteria from NWTS-33(1) - Program Objectives, Functional Requirements and System Performance Criteria. Appendix A, entitled Comparison with Other Siting Criteria compares the NWTS criteria with those recommended by other agencies. Appendix B contains DOE responses to public comments received on the January 1980 draft of this document. Appendix C is a glossary

  13. Updated ultrasound criteria for polycystic ovary syndrome: reliable thresholds for elevated follicle population and ovarian volume.

    Science.gov (United States)

    Lujan, Marla E; Jarrett, Brittany Y; Brooks, Eric D; Reines, Jonathan K; Peppin, Andrew K; Muhn, Narry; Haider, Ehsan; Pierson, Roger A; Chizen, Donna R

    2013-05-01

    Do the ultrasonographic criteria for polycystic ovaries supported by the 2003 Rotterdam consensus adequately discriminate between the normal and polycystic ovary syndrome (PCOS) condition in light of recent advancements in imaging technology and reliable methods for estimating follicle populations in PCOS? Using newer ultrasound technology and a reliable grid system approach to count follicles, we concluded that a substantially higher threshold of follicle counts throughout the entire ovary (FNPO)-26 versus 12 follicles-is required to distinguish among women with PCOS and healthy women from the general population. The Rotterdam consensus defined the polycystic ovary as having 12 or more follicles, measuring between 2 and 9 mm (FNPO), and/or an ovarian volume (OV) >10 cm(3). Since their initial proposal in 2003, a heightened prevalence of polycystic ovaries has been described in healthy women with regular menstrual cycles, which has questioned the accuracy of these criteria and marginalized the specificity of polycystic ovaries as a diagnostic criterion for PCOS. A diagnostic test study was performed using cross-sectional data, collected from 2006 to 2011, from 168 women prospectively evaluated by transvaginal ultrasonography. Receiver operating characteristic (ROC) curve analyses were performed to determine the appropriate diagnostic thresholds for: (i) FNPO, (ii) follicle counts in a single cross section (FNPS) and (iii) OV. The levels of intra- and inter-observer reliability when five observers used the proposed criteria on 100 ultrasound cases were also determined. Ninety-eight women diagnosed with PCOS by the National Institutes of Health criteria as having both oligo-amenorrhea and hyperandrogenism and 70 healthy female volunteers recruited from the general population. Participants were evaluated by transvaginal ultrasonography at the Royal University Hospital within the Department of Obstetrics, Gynecology and Reproductive Sciences, University of Saskatchewan

  14. Operational human performance reliability assessment (OHPRA)

    International Nuclear Information System (INIS)

    Haas, P.M.; Swanson, P.J.; Connelly, E.M.

    1993-01-01

    Operational Human Performance Reliability Assessment (OHPRA) is an approach for assessing human performance that is being developed in response to demands from modern process industries for practical and effective tools to assess and improve human performance, and therefore overall system performance and safety. The single most distinguishing feature of the approach is that is defines human performance in open-quotes operationalclose quotes terms. OHPRA is focused not on generation of human error probabilities, but on practical analysis of human performance to aid management in (1) identifying open-quotes fixableclose quotes problems and (2) providing input on the importance and nature of potential improvements. Development of the model in progress uses a unique approach for eliciting expert strategies for assessing performance. A PC-based model incorporating this expertise is planned. A preliminary version of the approach has already been used successfully to identify practical human performance problems in reactor and chemical process plant operations

  15. Models and criteria for LLW disposal performance

    International Nuclear Information System (INIS)

    Smith, C.F.; Cohen, J.J.

    1980-12-01

    A primary objective of the Low Level Waste (LLW) Management Program is to assure that public health is protected. Predictive modeling, to some extent, will play a role in meeting this objective. This paper considers the requirements and limitations of predictive modeling in providing useful inputs to waste mangement decision making. In addition, criteria development needs and the relation between criteria and models are discussed

  16. Models and criteria for LLW disposal performance

    International Nuclear Information System (INIS)

    Smith, C.F.; Cohen, J.J.

    1980-01-01

    A primary objective of the Low Level Waste (LLW) Management Program is to assure that public health is protected. Predictive modeling, to some extent, will play a role in meeting this objective. This paper considers the requirements and limitations of predictive modeling in providing useful inputs to waste management decision making. In addition, criteria development needs and the relation between criteria and models are discussed

  17. Verification criteria on the reliability of personal dosimetric services from x and gamma radiations

    International Nuclear Information System (INIS)

    Borasi, G.; Benco, A.; Kaftal, S.

    1990-07-01

    The paper presents the methods used by Working Group ENEA-EDP (Experts in Personal Dosimetry) to control the reliability of the Dosimetric Services operating in Italy and asking for the above controls on voluntary basis. Testing and irradiation test methods are explained as well as the evaluation criteria. The paper includes suggestions and guide-lines to gain the status of 'Reliable Service'. Technical equipment and operating procedures needed to pass the test are also illustrated. (author)

  18. A Model Of The Underlying Philosophy And Criteria For Effective Implementation Of Performance Management

    Directory of Open Access Journals (Sweden)

    C. M. Whitford

    2006-11-01

    Full Text Available The objective of this study was to develop a model that assists organisations in implementing performance management effectively. A model describing the philosophical paradigm underpinning best practice in performance management and the criteria for effective implementation of performance management was developed. The sample used in this study was a convenience sample of 615 employees. Exploratory factor analysis revealed three reliable philosophical dimensions. Moderate correlations were found between the three dimensions and some of the implementation criteria.

  19. Performance and reliability of LWR fuel

    International Nuclear Information System (INIS)

    Bairiot, H.; Deramaix, P.; Vandenberg, C.

    1977-01-01

    The main requirements for fuel reloads are: good reliability, minimum fuel cycle costs and flexibility of operation. Fulfilling these goals requires a background of experience. The approach to the acquisition of this experience in the particular case of BN has included over the last 15 years a proper development and cross-checking of the design methods and criteria, a continuous updating of the drawings and specifications and the qualification of adequate fabrication plants. This approach can best be outlined on the basis of the gradual implementation of the modern features of the LWR fuel. The first fuel clad with stainless steel was loaded in the BR 3 (11 MWe) in 1969 and later on (since 1974) in the SENA plant (310 MWe). Similarly, Zircaloy 4 cladding was first introduced in a reactor reload in 1969 as autoclaved cladding and later on (in 1971) the autoclaving was suppressed for the further reloads. Zircaloy 2 was loaded in DODEWAARD (51.5 MWe) in 1970. The first demonstration assembly in a PWR was a Pu-island assembly loaded in the BR 3 in 1963. It was followed by an all-Pu assembly in the same reactor in 1965 and by the loading of Pu fuels in four prototype assemblies in GARIGLIANO (160 MWe) in 1968. A full reload incorporating Pu fuel has been experienced by the supply of fuel for GARIGLIANO (BOL: 1975) and for BR 3 (BOL: 1972 and 1976). While in the early sixties the brazed design was still being utilized, the first assembly incorporating grids with springs was introduced in BR 3 in 1963. The first Inconel grids were loaded in the same reactor in 1969 and the first Zircaloy grids in 1972 (the first Zr grid has been loaded in a BWR in 1973). The experience covered successively the shrouded design (BOL: 1963), the shroudless design (BOL: 1969), a BWR assembly (BOL: 1971), a typical RCC assembly first with large diameter fuel rods (1972) and later on with small diameter fuel rods (1974). The experience on the reactivity control covered successively diluted

  20. Education Criteria for Performance Excellence, 2003.

    Science.gov (United States)

    American Society for Quality, Milwaukee, WI.

    The criteria described in this document are the basis for organizational self-assessments, for making awards, and for giving feedback to applicants. They are built upon the following values and concepts: visionary leadership; learning-centered education; organizational and personal learning; valuing faculty, staff, and partners; agility; focus on…

  1. Approaches to Demonstrating the Reliability and Validity of Core Diagnostic Criteria for Chronic Pain.

    Science.gov (United States)

    Bruehl, Stephen; Ohrbach, Richard; Sharma, Sonia; Widerstrom-Noga, Eva; Dworkin, Robert H; Fillingim, Roger B; Turk, Dennis C

    2016-09-01

    The Analgesic, Anesthetic, and Addiction Clinical Trial Translations, Innovations, Opportunities, and Networks-American Pain Society Pain Taxonomy (AAPT) is designed to be an evidence-based multidimensional chronic pain classification system that will facilitate more comprehensive and consistent chronic pain diagnoses, and thereby enhance research, clinical communication, and ultimately patient care. Core diagnostic criteria (dimension 1) for individual chronic pain conditions included in the initial version of AAPT will be the focus of subsequent empirical research to evaluate and provide evidence for their reliability and validity. Challenges to validating diagnostic criteria in the absence of clear and identifiable pathophysiological mechanisms are described. Based in part on previous experience regarding the development of evidence-based diagnostic criteria for psychiatric disorders, headache, and specific chronic pain conditions (fibromyalgia, complex regional pain syndrome, temporomandibular disorders, pain associated with spinal cord injuries), several potential approaches for documentation of the reliability and validity of the AAPT diagnostic criteria are summarized. The AAPT is designed to be an evidence-based multidimensional chronic pain classification system. Conceptual and methodological issues related to demonstrating the reliability and validity of the proposed AAPT chronic pain diagnostic criteria are discussed. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.

  2. Reliability based code calibration of fatigue design criteria of nuclear Class-1 piping

    International Nuclear Information System (INIS)

    Mishra, J.; Balasubramaniyan, V.; Chellapandi, P.

    2016-01-01

    Fatigue design of Class-l piping of NPP is carried out using Section-III of American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel code. The fatigue design criteria of ASME are based on the concept of safety factor, which does not provide means for the management of uncertainties for consistently reliable and economical designs. In this regards, a work is taken up to estimate the implicit reliability level associated with fatigue design criteria of Class-l piping specified by ASME Section III, NB-3650. As ASME fatigue curve is not in the form of analytical expression, the reliability level of pipeline fittings and joints is evaluated using the mean fatigue curve developed by Argonne National Laboratory (ANL). The methodology employed for reliability evaluation is FORM, HORSM and MCS. The limit state function for fatigue damage is found to be sensitive to eight parameters, which are systematically modelled as stochastic variables during reliability estimation. In conclusion a number of important aspects related to reliability of various piping product and joints are discussed. A computational example illustrates the developed procedure for a typical pipeline. (author)

  3. Test-retest reliability of the proposed DSM-5 eating disorder diagnostic criteria

    Science.gov (United States)

    Sysko, Robyn; Roberto, Christina A.; Barnes, Rachel D.; Grilo, Carlos M.; Attia, Evelyn; Walsh, B. Timothy

    2012-01-01

    The proposed DSM-5 classification scheme for eating disorders includes both major and minor changes to the existing DSM-IV diagnostic criteria. It is not known what effect these modifications will have on the ability to make reliable diagnoses. Two studies were conducted to evaluate the short-term test-retest reliability of the proposed DSM-5 eating disorder diagnoses: anorexia nervosa, bulimia nervosa, binge eating disorder, and feeding and eating conditions not elsewhere classified. Participants completed two independent telephone interviews with research assessors (n=70 Study 1; n=55 Study 2). Fair to substantial agreements (κ= 0.80 and 0.54) were observed across eating disorder diagnoses in Study 1 and Study 2, respectively. Acceptable rates of agreement were identified for the individual eating disorder diagnoses, including DSM-5 anorexia nervosa (κ’s of 0.81 to 0.97), bulimia nervosa (κ=0.84), binge eating disorder (κ’s of 0.75 and 0.61), and feeding and eating disorders not elsewhere classified (κ’s of 0.70 and 0.46). Further, improved short-term test-retest reliability was noted when using the DSM-5, in comparison to DSM-IV, criteria for binge eating disorder. Thus, these studies found that trained interviewers can reliably diagnose eating disorders using the proposed DSM-5 criteria; however, additional data from general practice settings and community samples are needed. PMID:22401974

  4. Measurement-based reliability/performability models

    Science.gov (United States)

    Hsueh, Mei-Chen

    1987-01-01

    Measurement-based models based on real error-data collected on a multiprocessor system are described. Model development from the raw error-data to the estimation of cumulative reward is also described. A workload/reliability model is developed based on low-level error and resource usage data collected on an IBM 3081 system during its normal operation in order to evaluate the resource usage/error/recovery process in a large mainframe system. Thus, both normal and erroneous behavior of the system are modeled. The results provide an understanding of the different types of errors and recovery processes. The measured data show that the holding times in key operational and error states are not simple exponentials and that a semi-Markov process is necessary to model the system behavior. A sensitivity analysis is performed to investigate the significance of using a semi-Markov process, as opposed to a Markov process, to model the measured system.

  5. 32 CFR 101.6 - Criteria for satisfactory performance.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Criteria for satisfactory performance. 101.6..., MILITARY AND CIVILIAN PARTICIPATION IN RESERVE TRAINING PROGRAMS § 101.6 Criteria for satisfactory...) Shall require members to: (1) Meet the standards of satisfactory performance of training duty set forth...

  6. 78 FR 7820 - Notice of Intelligent Mail Indicia Performance Criteria

    Science.gov (United States)

    2013-02-04

    ... FURTHER INFORMATION CONTACT: Marlo Kay Ivey, Business Programs Specialist, Payment Technology, U.S. Postal... Performance Criteria and Security Architecture for Open Information Based Indicia (IBI) Postage Evidencing Systems and the Performance Criteria and Security Architecture for Closed Information Based Indicia (IBI...

  7. Influence of organizational factors on performance reliability

    International Nuclear Information System (INIS)

    Haber, S.B.; O'Brien, J.N.; Metlay, D.S.; Crouch, D.A.

    1991-12-01

    This is the first volume of a two-volume report. Volume 2 will be published at a later date. This report presents the results of a research project conducted by Brookhaven National Laboratory for the United States Nuclear Regulatory Commission, Office of Nuclear Regulatory Research. The purpose of the project was to develop a general methodology to be use in the assessment of the organizational factors which affect performance reliability (safety) in a nuclear power plant. The research described in this report includes the development of the Nuclear Organization and Management Analysis Concept (GNOMIC). This concept characterizes the organizational factors that impact safety performance in a nuclear power plant and identifies some methods for systematically measuring and analyzing the influence of these factors on safety performance. This report is divided into two parts; Part 1 presents an overview of the development of the methodology, while Part 2 provides more details and a technical analysis of the methodological development. Specifically, the results of two demonstration studies, the feasibility of the methodology, and a specific applications for which the methodology was developed are presented

  8. Determination of reliability criteria for standby diesel generators at a nuclear power station

    International Nuclear Information System (INIS)

    Evans, M.G.K.

    1987-01-01

    The requirement for standby diesel generators at nuclear power stations is developed and a probabilistic approach used to define the reliability parameters. The present criteria used when ordering a diesel generator are compared with the testing required by the regulatory body and the most likely requirement following an accident. The impact of this on the diesels at a particular station and the root cause of failures are discussed. (orig.)

  9. Once is not enough : Establishing reliability criteria for teacher evaluation based on classroom observations

    NARCIS (Netherlands)

    van der Lans, Rikkert; van de Grift, Wim; van Veen, Klaas

    2016-01-01

    Classroom observation is the most implemented method to evaluate teaching. To ensure reliability, researchers often train observers extensively. However, schools have limited resources to train observers and often lesson observation is performed by limitedly trained or untrained colleagues. In this

  10. State-wide performance criteria for international safeguards

    International Nuclear Information System (INIS)

    Budlong-Sylvester, K.W.; Pilat, Joseph F.; Stanbro, W.D.

    2001-01-01

    Traditionally, the International Atomic Energy Agency (IAEA) has relied upon prescriptive criteria to guide safeguards implementation. The prospect of replacing prescriptive safeguards criteria with more flexible performance criteria would constitute a structural change in safeguards and raises several important questions. Performance criteria imply that while safeguards goals will be fixed, the means of attaining those goals will not be explicitly prescribed. What would the performance objectives be under such a system? How would they be formulated? How would performance be linked to higher level safeguards objectives? How would safeguards performance be measured State-wide? The implementation of safeguards under performance criteria would also signal a dramatic change in the manner the Agency does business. A higher degree of flexibility could, in principle, produce greater effectiveness and efficiency, but would come with a need for increased Agency responsibility in practice. To the extent that reliance on prescriptive criteria decreases, the burden of justifying actions and ensuring their transparency will rise. Would there need to be limits to safeguards implementation? What would be the basis for setting such limits? This paper addresses these and other issues and questions relating to both the formulation and the implementation of performance-based criteria.

  11. Performance Criteria of Nuclear Space Propulsion Systems

    Science.gov (United States)

    Shepherd, L. R.

    Future exploration of the solar system on a major scale will require propulsion systems capable of performance far greater than is achievable with the present generation of rocket engines using chemical propellants. Viable missions going deeper into interstellar space will be even more demanding. Propulsion systems based on nuclear energy sources, fission or (eventually) fusion offer the best prospect for meeting the requirements. The most obvious gain coming from the application of nuclear reactions is the possibility, at least in principle, of obtaining specific impulses a thousandfold greater than can be achieved in chemically energised rockets. However, practical considerations preclude the possibility of exploiting the full potential of nuclear energy sources in any engines conceivable in terms of presently known technology. Achievable propulsive power is a particularly limiting factor, since this determines the acceleration that may be obtained. Conventional chemical rocket engines have specific propulsive powers (power per unit engine mass) in the order of gigawatts per tonne. One cannot envisage the possibility of approaching such a level of performance by orders of magnitude in presently conceivable nuclear propulsive systems. The time taken, under power, to reach a given terminal velocity is proportional to the square of the engine's exhaust velocity and the inverse of its specific power. An assessment of various nuclear propulsion concepts suggests that, even with the most optimistic assumptions, it could take many hundreds of years to attain the velocities necessary to reach the nearest stars. Exploration within a range of the order of a thousand AU, however, would appear to offer viable prospects, even with the low levels of specific power of presently conceivable nuclear engines.

  12. Assessing the reliability of skilled performance

    International Nuclear Information System (INIS)

    Dougherty, E.M.; Collins, E.P.

    1996-01-01

    In some high-hazard military tasks, precision of motor skills is crucial to avoid a risk-sensitive drop or other mishap. Sparse data supports a basic level of reliability for this activity seemingly much lower than typical, individual action, slip-mode errors would yield. A typical occurrence failure rate seems to be of the order of 1 x 10 -5 per opportunity. A speculation is tendered that this represents a difference in kind; that the reliability of skills is a different taxon than previously called out in the typical scheme of human reliability

  13. A methodology and success/failure criteria for determining emergency diesel generator reliability

    Energy Technology Data Exchange (ETDEWEB)

    Wyckoff, H. L. [Electric Power Research Institute, Palo Alto, California (United States)

    1986-02-15

    In the U.S., comprehensive records of nationwide emergency diesel generator (EDG) reliability at nuclear power plants have not been consistently collected. Those surveys that have been undertaken have not always been complete and accurate. Moreover, they have been based On an extremely conservative methodology and success/failure criteria that are specified in U.S. Nuclear Regulatory Commission Reg. Guide 1.108. This Reg. Guide was one of the NRCs earlier efforts and does not yield the caliber of statistically defensible reliability values that are now needed. On behalf of the U.S. utilities, EPRI is taking the lead in organizing, investigating, and compiling a realistic database of EDG operating success/failure experience for the years 1983, 1984 and 1985. These data will be analyzed to provide an overall picture of EDG reliability. This paper describes the statistical methodology and start and run success/- failure criteria that EPRI is using. The survey is scheduled to be completed in March 1986. (author)

  14. A methodology and success/failure criteria for determining emergency diesel generator reliability

    International Nuclear Information System (INIS)

    Wyckoff, H.L.

    1986-01-01

    In the U.S., comprehensive records of nationwide emergency diesel generator (EDG) reliability at nuclear power plants have not been consistently collected. Those surveys that have been undertaken have not always been complete and accurate. Moreover, they have been based On an extremely conservative methodology and success/failure criteria that are specified in U.S. Nuclear Regulatory Commission Reg. Guide 1.108. This Reg. Guide was one of the NRCs earlier efforts and does not yield the caliber of statistically defensible reliability values that are now needed. On behalf of the U.S. utilities, EPRI is taking the lead in organizing, investigating, and compiling a realistic database of EDG operating success/failure experience for the years 1983, 1984 and 1985. These data will be analyzed to provide an overall picture of EDG reliability. This paper describes the statistical methodology and start and run success/- failure criteria that EPRI is using. The survey is scheduled to be completed in March 1986. (author)

  15. Inter-rater reliability of diagnostic criteria for sacroiliac joint-, disc- and facet joint pain.

    Science.gov (United States)

    van Tilburg, Cornelis W J; Groeneweg, Johannes G; Stronks, Dirk L; Huygen, Frank J P M

    2017-01-01

    Several diagnostic criteria sets are described in the literature to identify low back pain subtypes, but very little is known about the inter-rater reliability of these criteria. We conducted a study to determine the reliability of diagnostic tests that point towards SI joint-, disc- or facet joint pain. Inter-rater reliability study alongside three randomized clinical trials. Multidisciplinary pain center of general hospital. Patients aged 18 or more with medical history and physical examination suggestive of sacroiliac joint-, disc- and facet joint pain on lumbar level. Making use of nowadays most common used diagnostic criteria, a physical examination is taken independently by three physicians (two pain physicians and one orthopedic surgeon). Inter-rater reliability (Kappa (κ) measure of agreement) and significance (p) between raters are presented. Strengths of agreement, indicated with κ values above 0,20, are presented in order of agreement. One hundred patients were included. None of the parameters from the physical investigation had κ values of more than 0.21 (fair) in all pairs of raters. Between two raters (C and D), there was an almost perfect agreement on three parameters, more specifically ``Abnormal sensory and motor examination, hyperactive or diminished reflexes'', ``Sitting exam shows no reflex, motor or sensory signs in the legs'' and ``Straight leg raising (Laségue) negative between 30 and 70 degrees of flexion''. The ``Drop test positive'' parameters had moderate strength of agreement between raters A and D and fair strength between raters A and B. The ``Digital interspinous pressure test positive'' had moderate strength of agreement between raters C and D and fair strength of agreement between raters A and B as well as raters B and C. Three other parameters had a fair strength of agreement between two raters, all other parameters had a slight or poor strength of agreement. Inter-rater reliability, confidence intervals and significance of

  16. Reliability of stellar inclination estimated from asteroseismology: analytical criteria, mock simulations and Kepler data analysis

    Science.gov (United States)

    Kamiaka, Shoya; Benomar, Othman; Suto, Yasushi

    2018-05-01

    Advances in asteroseismology of solar-like stars, now provide a unique method to estimate the stellar inclination i⋆. This enables to evaluate the spin-orbit angle of transiting planetary systems, in a complementary fashion to the Rossiter-McLaughlineffect, a well-established method to estimate the projected spin-orbit angle λ. Although the asteroseismic method has been broadly applied to the Kepler data, its reliability has yet to be assessed intensively. In this work, we evaluate the accuracy of i⋆ from asteroseismology of solar-like stars using 3000 simulated power spectra. We find that the low signal-to-noise ratio of the power spectra induces a systematic under-estimate (over-estimate) bias for stars with high (low) inclinations. We derive analytical criteria for the reliable asteroseismic estimate, which indicates that reliable measurements are possible in the range of 20° ≲ i⋆ ≲ 80° only for stars with high signal-to-noise ratio. We also analyse and measure the stellar inclination of 94 Kepler main-sequence solar-like stars, among which 33 are planetary hosts. According to our reliability criteria, a third of them (9 with planets, 22 without) have accurate stellar inclination. Comparison of our asteroseismic estimate of vsin i⋆ against spectroscopic measurements indicates that the latter suffers from a large uncertainty possibly due to the modeling of macro-turbulence, especially for stars with projected rotation speed vsin i⋆ ≲ 5km/s. This reinforces earlier claims, and the stellar inclination estimated from the combination of measurements from spectroscopy and photometric variation for slowly rotating stars needs to be interpreted with caution.

  17. Reliability, Resilience, and Vulnerability criteria for the evaluation of Human Health Risks

    Science.gov (United States)

    Rodak, C. M.; Silliman, S. E.; Bolster, D.

    2011-12-01

    Understanding the impact of water quality on the health of a general population is challenging due high degrees of uncertainty and variability in hydrological, toxicological and human aspects of the system. Assessment of the impact of changes in water quality of a public water supply is critical to management of that water supply. We propose the use of three different system evaluation criteria: Reliability, Resilience and Vulnerability (RRV) as a tool for assessing the impact of uncertainty in the arrival of contaminant mass through time with respect to human health risks on a variable population. These criteria were first introduced to the water resources community by Hashimoto et al (1982). Most simply one can understand these criteria as the following: Reliability is the likelihood of the system being in a state of success; Resilience is the probability that the system will return to a state of success at t+1 if it is in failure at time step t, and Vulnerability is the severity of failure, which here is defined as the maximum health risk. These concepts are applied to a theoretical example where the water quality at a water supply well varies over time: health impact is considered based on sliding, 30-year windows of exposure to water derived from the well. We apply the methodology, in terms of uncertainty in water quality deviations, to eight simulated breakthrough curves of a contaminant at the well: each curve represents equal mass of contaminant arriving at the well over a 70-year lifetime of the well, but different mass distributions over time. These curves are used to investigate the impact of uncertainty in the distribution through time of the contaminant mass at the well, as well as the initial arrival of the contaminant over the 70-year lifetime of the well. In addition to extending the health risk through time with uncertainty in mass distribution, we incorporate variability in the human population to examine the evolution of the three criteria within

  18. Evaluation criteria for enhanced solar–coal hybrid power plant performance

    International Nuclear Information System (INIS)

    Zhao, Yawen; Hong, Hui; Jin, Hongguang

    2014-01-01

    Attention has been directed toward hybridizing solar energy with fossil power plants since the 1990s to improve reliability and efficiency. Appropriate evaluation criteria were important in the design and optimization of solar–fossil hybrid systems. Two new criteria to evaluate the improved thermodynamic performances in a solar hybrid power plant were developed in this study. Correlations determined the main factors influencing the improved thermodynamic performances. The proposed criteria can be used to effectively integrate solar–coal hybridization systems. Typical 100 MW–1000 MW coal-fired power plants hybridized with solar heat at approximately 300 °C, which was used to preheat the feed water before entering the boiler, were evaluated using the criteria. The integration principle of solar–coal hybrid systems was also determined. The proposed evaluation criteria may be simple and reasonable for solar–coal hybrid systems with multi-energy input, thus directing system performance enhancement. - Highlights: • New criteria to evaluate the solar hybrid power plant were developed. • Typical solar–coal hybrid power plants were evaluated using the criteria. • The integration principle of solar–coal hybrid systems was determined. • The benefits of the solar–coal hybrid system are enhanced at lower solar radiation

  19. Operator performance evaluation using multi criteria decision making methods

    Science.gov (United States)

    Rani, Ruzanita Mat; Ismail, Wan Rosmanira; Razali, Siti Fatihah

    2014-06-01

    Operator performance evaluation is a very important operation in labor-intensive manufacturing industry because the company's productivity depends on the performance of its operators. The aims of operator performance evaluation are to give feedback to operators on their performance, to increase company's productivity and to identify strengths and weaknesses of each operator. In this paper, six multi criteria decision making methods; Analytical Hierarchy Process (AHP), fuzzy AHP (FAHP), ELECTRE, PROMETHEE II, Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS) and VlseKriterijumska Optimizacija I Kompromisno Resenje (VIKOR) are used to evaluate the operators' performance and to rank the operators. The performance evaluation is based on six main criteria; competency, experience and skill, teamwork and time punctuality, personal characteristics, capability and outcome. The study was conducted at one of the SME food manufacturing companies in Selangor. From the study, it is found that AHP and FAHP yielded the "outcome" criteria as the most important criteria. The results of operator performance evaluation showed that the same operator is ranked the first using all six methods.

  20. A framework of performance criteria defining sustainable construction technologies

    International Nuclear Information System (INIS)

    Sturges, W.G.

    1992-01-01

    As our global culture encounters accelerating rates of resource depletion, environmental degradation, and societal inequality, it increasingly needs tools to rate building systems by environmental and socioeconomic criteria. By investigating light frame structural systems based on principles of ecological design, it is possible to not only identify the structures' potential impacts on the health of their site and larger community, but also to establish a framework of performance criteria for comparatively evaluating a variety of construction technologies. This paper summarizes the development and application of such a framework, based upon the ecosystems and culture of the Pacific Northwest's Cascadia Bioregion. The framework has been comparatively applied to solid-sawn lumber, trusses, and composite wood I-joists. These three framing technologies together represent traditional, contemporary, and progressive structural systems. Their individual and collective performance, based upon the application of the hypothesized criteria, offer insights into what might be a more ideal framing system of the sustainable future

  1. A Psychometric Evaluation of the DSM-IV Criteria for Antisocial Personality Disorder: Dimensionality, Local Reliability, and Differential Item Functioning Across Gender.

    Science.gov (United States)

    Paap, Muirne C S; Braeken, Johan; Pedersen, Geir; Urnes, Øyvind; Karterud, Sigmund; Wilberg, Theresa; Hummelen, Benjamin

    2017-12-01

    This study aims at evaluating the psychometric properties of the antisocial personality disorder (ASPD) criteria in a large sample of patients, most of whom had one or more personality disorders (PD). PD diagnoses were assessed by experienced clinicians using the Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders, 4th edition, Axis II PDs. Analyses were performed within an item response theory framework. Results of the analyses indicated that ASPD is a unidimensional construct that can be measured reliably at the upper range of the latent trait scale. Differential item functioning across gender was restricted to two criteria and had little impact on the latent ASPD trait level. Patients fulfilling both the adult ASPD criteria and the conduct disorder criteria had similar latent trait distributions as patients fulfilling only the adult ASPD criteria. Overall, the ASPD items fit the purpose of a diagnostic instrument well, that is, distinguishing patients with moderate from those with high antisocial personality scores.

  2. Seismic design and evaluation criteria based on target performance goals

    International Nuclear Information System (INIS)

    Murray, R.C.; Nelson, T.A.; Kennedy, R.P.; Short, S.A.

    1994-04-01

    The Department of Energy utilizes deterministic seismic design/evaluation criteria developed to achieve probabilistic performance goals. These seismic design and evaluation criteria are intended to apply equally to the design of new facilities and to the evaluation of existing facilities. In addition, the criteria are intended to cover design and evaluation of buildings, equipment, piping, and other structures. Four separate sets of seismic design/evaluation criteria have been presented each with a different performance goal. In all these criteria, earthquake loading is selected from seismic hazard curves on a probabilistic basis but seismic response evaluation methods and acceptable behavior limits are deterministic approaches with which design engineers are familiar. For analytical evaluations, conservatism has been introduced through the use of conservative inelastic demand-capacity ratios combined with ductile detailing requirements, through the use of minimum specified material strengths and conservative code capacity equations, and through the use of a seismic scale factor. For evaluation by testing or by experience data, conservatism has been introduced through the use of an increase scale factor which is applied to the prescribed design/evaluation input motion

  3. Catalysis for biorefineries-performance criteria for industrial operation

    NARCIS (Netherlands)

    Lange, Jean Paul

    2016-01-01

    Past analyses of industrial processes for fuel and chemical manufacturing led to a few performance criteria that are critical for viable industrial operation. The present paper reviews these factors and provides a target window for each of them. It then illustrates their relevance for biorefineries

  4. Multivariate performance reliability prediction in real-time

    International Nuclear Information System (INIS)

    Lu, S.; Lu, H.; Kolarik, W.J.

    2001-01-01

    This paper presents a technique for predicting system performance reliability in real-time considering multiple failure modes. The technique includes on-line multivariate monitoring and forecasting of selected performance measures and conditional performance reliability estimates. The performance measures across time are treated as a multivariate time series. A state-space approach is used to model the multivariate time series. Recursive forecasting is performed by adopting Kalman filtering. The predicted mean vectors and covariance matrix of performance measures are used for the assessment of system survival/reliability with respect to the conditional performance reliability. The technique and modeling protocol discussed in this paper provide a means to forecast and evaluate the performance of an individual system in a dynamic environment in real-time. The paper also presents an example to demonstrate the technique

  5. EVALUATION OF SERVICE SUPPLY CHAIN PERFORMANCE CRITERIA WITH DANP METHOD

    OpenAIRE

    ÖZVERİ, Onur; GÜÇLÜ, Pembe; AYCİN, Ejder

    2018-01-01

    Despite the service industry composes large part of the world economy, the academic studies and applications on supply chain are mainly about production industry. Because of the different structure of services, the service supply chain and also performance criteria-metrics differ from the product supply chain. The aim of this paper is to evaluate the supply chain performance metrics for restaurant sector. For this purpose in the first and second part of the paper the service supply chain conc...

  6. Reliability of Left Ventricular Hypertrophy by ECG Criteria in Children with Syncope: Do the Criteria Need to be Revised?

    Science.gov (United States)

    Banerjee, Maalika M; Ramesh Iyer, V; Nandi, Deipanjan; Vetter, Victoria L; Banerjee, Anirban

    2016-04-01

    In the outpatient setting, children who present with syncope routinely undergo electrocardiograms (ECG). Because of concerns for hypertrophic cardiomyopathy, children with syncope meeting ECG criteria for left ventricular hypertrophy (LVH) will frequently undergo an echocardiogram. Our objectives were to determine whether Davignon criteria for ECG waves overestimate LVH in children presenting with syncope, and to study the usefulness of echocardiography in these children. We hypothesize that the Davignon criteria presently used for interpretation of ECGs overestimate LVH, resulting in unnecessary echocardiography in this clinical setting. The clinical database of The Children's Hospital of Philadelphia was evaluated from 2002 to 2012 to identify children between 9 and 16 years of age, who presented with non-exercise-induced, isolated syncope. From this group of patients, only those with clear-cut evidence of LVH (by Davignon criteria), who also underwent an echocardiogram, were selected. A total of 136 children with syncope were identified as having LVH by Davignon ECG criteria. None of these patients manifested any evidence of hypertrophic cardiomyopathy, with normal ventricular septum (average Z-score -0.68 ± 0.84), LV posterior wall (average Z-score -0.66 ± 1.18) and LV mass (average Z-score 0.52 ± 1.29). No significant correlation was found between summed RV6 plus SV1 and LV mass. Correlations between additional ECG parameters and measures of LVH by echocardiography were similarly poor. In children presenting with syncope and LVH by ECG, there was no evidence of true LVH by echocardiography. We propose that the Davignon ECG criteria for interpreting LVH in children overestimate the degree of hypertrophy in these children and the yield of echocardiography is extremely low.

  7. Performance reliability prediction for thermal aging based on kalman filtering

    International Nuclear Information System (INIS)

    Ren Shuhong; Wen Zhenhua; Xue Fei; Zhao Wensheng

    2015-01-01

    The performance reliability of the nuclear power plant main pipeline that failed due to thermal aging was studied by the performance degradation theory. Firstly, through the data obtained from the accelerated thermal aging experiments, the degradation process of the impact strength and fracture toughness of austenitic stainless steel material of the main pipeline was analyzed. The time-varying performance degradation model based on the state space method was built, and the performance trends were predicted by using Kalman filtering. Then, the multi-parameter and real-time performance reliability prediction model for the main pipeline thermal aging was developed by considering the correlation between the impact properties and fracture toughness, and by using the stochastic process theory. Thus, the thermal aging performance reliability and reliability life of the main pipeline with multi-parameter were obtained, which provides the scientific basis for the optimization management of the aging maintenance decision making for nuclear power plant main pipelines. (authors)

  8. Complex proximal humerus fractures: Hertel's criteria reliability to predict head necrosis.

    Science.gov (United States)

    Campochiaro, G; Rebuzzi, M; Baudi, P; Catani, F

    2015-09-01

    The risk of post-traumatic humeral head avascular necrosis (AVN), regardless of the treatment, has a high reported incidence. In 2004, Hertel et al. stated that the most relevant predictors of ischemia after intracapsular fracture treated with osteosynthesis are the calcar length, medial hinge integrity and some specific fracture types. Based on Hertel's model, the purpose of this study is to evaluate both its reliability and weaknesses in our series of 267 fractures, assessing how the anatomical configuration of fracture, the quality of reduction and its maintenance were predictive of osteonecrosis development, and so to suggest a treatment choice algorithm. A retrospective study, level of evidence IV, was conducted to duly assess the radiographic features of 267 fractures treated from 2004 to 2010 following Hertel's criteria treated with open reduction and internal fixation by angular stability plates and screws. The average age was 65.2 years. The average follow-up was 28.3 ± 17.0 months. The percentage of AVN, the quality and maintenance of reduction obtained during surgery were evaluated. The AVN incidence was 3.7 %. No significant correlation with gender, age and fracture type was found. At the last follow-up X-ray, only 30 % presented all Hertel's good predictors in the AVN group, 4.7 % in the non-AVN group (p AVN group, it was poor in 50 %; while in the non-AVN group, it was poor in 3.4 % (p AVN were symptomatic, and three needed a second surgery. Hertel's criteria are important in the surgical planning, but they are not sufficient: an accurate evaluation of the calcar area fracture in three planes is required. All fractures involving calcar area should be studied with CT.

  9. Quality improvement using the Baldrige Criteria for Organizational Performance Excellence.

    Science.gov (United States)

    DeJong, Douglas J

    2009-06-01

    The criteria needed to achieve the Malcolm Baldrige National Quality Award (MBNQA) are described. The MBNQA was created in 1987 to recognize quality and performance and to encourage excellence in American companies. In 2003, Saint Luke's Hospital, the largest hospital in the Saint Luke's Health System, received the MBNQA. In the years since, the hospital has continued to use the Baldrige approach and has pursued the award on the health-system level. The Baldrige Criteria for Organizational Performance Excellence provide a framework that focuses on obtaining the highest levels of organizational excellence. These criteria consist of seven categories-leadership; strategic planning; focus on patients, customers, and markets; measurement, analysis, and knowledge management; work-force focus; process management; and results. At Saint Luke's Hospital, a category leader was designated for each of the seven categories in order to fully apply the criteria to the organization. Pharmacy leaders worked closely with each category leader to ensure that the appropriate format was being followed and to contribute positively to the written application and the site visit conducted by MBNQA examiners. The MBNQA involves its own vernacular and pattern. Effort should be made to fully understand and embrace the path that the organization's leaders have chosen. Departmental activities should be placed in front of an individual's leadership so that he or she can play an active part in demonstrating quality-improvement success stories. The criteria for the MBNQA are structured around seven categories that form a framework by which any organization or department can structure its own pursuit of quality and excellence. Pharmacy leaders can play an important role in the successful pursuit of quality within their organization.

  10. A new set of qualitative reliability criteria to aid inferences on palaeomagnetic dipole moment variations through geological time

    Directory of Open Access Journals (Sweden)

    Andrew John Biggin

    2014-10-01

    Full Text Available Records of reversal frequency support forcing of the geodynamo over geological timescales but obtaining these for earlier times (e.g. the Precambrian is a major challenge. Changes in the measured virtual (axial dipole moment of the Earth, averaged over several millions of years or longer, also have the potential to constrain core and mantle evolution through deep time. There have been a wealth of recent innovations in palaeointensity methods, but there is, as yet, no comprehensive means for assessing the reliability of new and existing dipole moment data. Here we present a new set of largely qualitative reliability criteria for palaeointensity results at the site mean level, which we term QPI in reference to the long-standing Q criteria used for assessing palaeomagnetic poles. These represent the first attempt to capture the range of biasing agents applicable to palaeointensity measurements and to recognise the various approaches employed to obviate them. A total of 8 criteria are proposed and applied to 312 dipole moment estimates recently incorporated into the PINT global database. The number of these criteria fulfilled by a single dipole moment estimate (the QPI value varies between 1 and 6 in the examined dataset and has a median of 3. Success rates for each of the criteria are highly variable, but each criterion was met by at least a few results. The new criteria will be useful for future studies as a means of gauging the reliability of new and published dipole moment estimates.

  11. Reliable predictions of waste performance in a geologic repository

    International Nuclear Information System (INIS)

    Pigford, T.H.; Chambre, P.L.

    1985-08-01

    Establishing reliable estimates of long-term performance of a waste repository requires emphasis upon valid theories to predict performance. Predicting rates that radionuclides are released from waste packages cannot rest upon empirical extrapolations of laboratory leach data. Reliable predictions can be based on simple bounding theoretical models, such as solubility-limited bulk-flow, if the assumed parameters are reliably known or defensibly conservative. Wherever possible, performance analysis should proceed beyond simple bounding calculations to obtain more realistic - and usually more favorable - estimates of expected performance. Desire for greater realism must be balanced against increasing uncertainties in prediction and loss of reliability. Theoretical predictions of release rate based on mass-transfer analysis are bounding and the theory can be verified. Postulated repository analogues to simulate laboratory leach experiments introduce arbitrary and fictitious repository parameters and are shown not to agree with well-established theory. 34 refs., 3 figs., 2 tabs

  12. Does Residency Selection Criteria Predict Performance in Orthopaedic Surgery Residency?

    Science.gov (United States)

    Raman, Tina; Alrabaa, Rami George; Sood, Amit; Maloof, Paul; Benevenia, Joseph; Berberian, Wayne

    2016-04-01

    More than 1000 candidates applied for orthopaedic residency positions in 2014, and the competition is intense; approximately one-third of the candidates failed to secure a position in the match. However, the criteria used in the selection process often are subjective and studies have differed in terms of which criteria predict either objective measures or subjective ratings of resident performance by faculty. Do preresidency selection factors serve as predictors of success in residency? Specifically, we asked which preresidency selection factors are associated or correlated with (1) objective measures of resident knowledge and performance; and (2) subjective ratings by faculty. Charts of 60 orthopaedic residents from our institution were reviewed. Preresidency selection criteria examined included United States Medical Licensing Examination (USMLE) Step 1 and Step 2 scores, Medical College Admission Test (MCAT) scores, number of clinical clerkship honors, number of letters of recommendation, number of away rotations, Alpha Omega Alpha (AOA) honor medical society membership, fourth-year subinternship at our institution, and number of publications. Resident performance was assessed using objective measures including American Board of Orthopaedic Surgery (ABOS) Part I scores and Orthopaedics In-Training Exam (OITE) scores and subjective ratings by faculty including global evaluation scores and faculty rankings of residents. We tested associations between preresidency criteria and the subsequent objective and subjective metrics using linear correlation analysis and Mann-Whitney tests when appropriate. Objective measures of resident performance namely, ABOS Part I scores, had a moderate linear correlation with the USMLE Step 2 scores (r = 0.55, p communication skills" subsection of the global evaluations. We found that USMLE Step 2, number of honors in medical school clerkships, and AOA membership demonstrated the strongest correlations with resident performance. Our

  13. Establishing reliability of performance indicator of sepak takraw ...

    African Journals Online (AJOL)

    The aim of this study is to establish the necessary reliability in the notational analysis of sepak takraw. Two performance analysts were recruited to help in the collection of the data. The performances were analyzed based on the main performance indicators relevant to the demand of the game. Cronbach's alpha and ...

  14. Comparison of two approaches for establishing performance criteria related to Maintenance Rule

    International Nuclear Information System (INIS)

    Jerng, Dong-Wook; Kim, Man Cheol

    2015-01-01

    Probabilistic safety assessment (PSA) serves as a tool for systemically analyzing the safety of nuclear power plants. This paper explains and compares two approaches for the establishment of performance criteria related to the Maintenance Rule: (1) the individual reliability-based approach, and (2) the PSA importance measure-based approach. Different characteristics of the two approaches were compared in a qualitative manner, while a quantitative comparison was performed through application of the two approaches to a nuclear power plant. It was observed that the individual reliability-based approach resulted in more conservative performance criteria, compared to the PSA importance measure-based approach. It is thus expected that the PSA importance measure-based approach will allow for more flexible maintenance policy under conditions of limited resources, while providing for a macroscopic view of overall plant safety. Based on insights derived through this analysis, we emphasize the importance of a balance between reliability and safety significance, and propose a balance measure accordingly. The conclusions of this analysis are likely to be applicable to other types of nuclear power plants. (author)

  15. Criteria and algorithms for constructing reliable databases for statistical analysis of disruptions at ASDEX Upgrade

    International Nuclear Information System (INIS)

    Cannas, B.; Fanni, A.; Pautasso, G.; Sias, G.; Sonato, P.

    2009-01-01

    The present understanding of disruption physics has not gone so far as to provide a mathematical model describing the onset of this instability. A disruption prediction system, based on a statistical analysis of the diagnostic signals recorded during the experiments, would allow estimating the probability of a disruption to take place. A crucial point for a good design of such a prediction system is the appropriateness of the data set. This paper reports the details of the database built to train a disruption predictor based on neural networks for ASDEX Upgrade. The criteria of pulses selection, the analyses performed on plasma parameters and the implemented pre-processing algorithms, are described. As an example of application, a short description of the disruption predictor is reported.

  16. A multi-criteria vertical coordination framework for a reliable aid distribution

    International Nuclear Information System (INIS)

    Regis-Hernández, Fabiola; Mora-Vargas, Jaime; Ruíz, Angel

    2017-01-01

    This study proposes a methodology that translates multiple humanitarian supply chain stakeholders’ preferences from qualitative to quantitative values, enabling these preferences to be integrated into optimization models to ensure their balanced and simultaneous implementation during the decision-making process. Design/methodology/approach: An extensive literature review is used to justify the importance of developing a strategy that minimizes the impact of a lack of coordination on humanitarian logistics decisions. A methodology for a multi-criteria framework is presented that allows humanitarian stakeholders’ interests to be integrated into the humanitarian decision-making process. Findings: The findings suggest that integrating stakeholders’ interests into the humanitarian decision-making process will improve its reliability. Research limitations/implications: To further validate the weights of each stakeholder’s interests obtained from the literature review requires interviews with the corresponding organizations. However, the literature review supports the statements in this paper. Practical implications: The cost of a lack of coordination between stakeholders in humanitarian logistics has been increasing during the last decade. These coordination costs can be minimized if humanitarian logistics’ decision-makers measure and simultaneously consider multiple stakeholders’ preferences. Social implications: When stakeholders’ goals are aligned, the humanitarian logistics response becomes more efficient, increasing the quality of delivered aid and providing timely assistance to the affected population in order to minimize their suffering. This study provides a methodology that translates humanitarian supply chain stakeholders’ interests into quantitative values, enabling them to be integrated into mathematical models to ensure relief distribution based on the stakeholders’ preferences

  17. A multi-criteria vertical coordination framework for a reliable aid distribution

    Energy Technology Data Exchange (ETDEWEB)

    Regis-Hernández, Fabiola; Mora-Vargas, Jaime; Ruíz, Angel

    2017-07-01

    This study proposes a methodology that translates multiple humanitarian supply chain stakeholders’ preferences from qualitative to quantitative values, enabling these preferences to be integrated into optimization models to ensure their balanced and simultaneous implementation during the decision-making process. Design/methodology/approach: An extensive literature review is used to justify the importance of developing a strategy that minimizes the impact of a lack of coordination on humanitarian logistics decisions. A methodology for a multi-criteria framework is presented that allows humanitarian stakeholders’ interests to be integrated into the humanitarian decision-making process. Findings: The findings suggest that integrating stakeholders’ interests into the humanitarian decision-making process will improve its reliability. Research limitations/implications: To further validate the weights of each stakeholder’s interests obtained from the literature review requires interviews with the corresponding organizations. However, the literature review supports the statements in this paper. Practical implications: The cost of a lack of coordination between stakeholders in humanitarian logistics has been increasing during the last decade. These coordination costs can be minimized if humanitarian logistics’ decision-makers measure and simultaneously consider multiple stakeholders’ preferences. Social implications: When stakeholders’ goals are aligned, the humanitarian logistics response becomes more efficient, increasing the quality of delivered aid and providing timely assistance to the affected population in order to minimize their suffering. This study provides a methodology that translates humanitarian supply chain stakeholders’ interests into quantitative values, enabling them to be integrated into mathematical models to ensure relief distribution based on the stakeholders’ preferences.

  18. The strategic selecting criteria and performance by using the multiple criteria method

    Directory of Open Access Journals (Sweden)

    Lisa Y. Chen

    2008-02-01

    Full Text Available As the increasing competitive intensity in the current service market, organizational capabilities have been recognized as the importance of sustaining competitive advantage. The profitable growth for the firms has been fueled a need to systematically assess and renew the organization. The purpose of this study is to analyze the financial performance of the firms to create an effective evaluating structure for the Taiwan's service industry. This study utilized TOPSIS (technique for order preference by similarity to ideal solution method to evaluate the operating performance of 12 companies. TOPSIS is a multiple criteria decision making method to identify solutions from a finite set of alternatives based upon simultaneous minimization of distance from an ideal point and maximization of distance from a nadir point. By using this approach, this study measures the financial performance of firms through two aspects and ten indicators. The result indicated e-life had outstanding performance among the 12 retailers. The findings of this study provided managers to better understand their market position, competition, and profitability for future strategic planning and operational management.

  19. The development of a reliable amateur boxing performance analysis template.

    Science.gov (United States)

    Thomson, Edward; Lamb, Kevin; Nicholas, Ceri

    2013-01-01

    The aim of this study was to devise a valid performance analysis system for the assessment of the movement characteristics associated with competitive amateur boxing and assess its reliability using analysts of varying experience of the sport and performance analysis. Key performance indicators to characterise the demands of an amateur contest (offensive, defensive and feinting) were developed and notated using a computerised notational analysis system. Data were subjected to intra- and inter-observer reliability assessment using median sign tests and calculating the proportion of agreement within predetermined limits of error. For all performance indicators, intra-observer reliability revealed non-significant differences between observations (P > 0.05) and high agreement was established (80-100%) regardless of whether exact or the reference value of ±1 was applied. Inter-observer reliability was less impressive for both analysts (amateur boxer and experienced analyst), with the proportion of agreement ranging from 33-100%. Nonetheless, there was no systematic bias between observations for any indicator (P > 0.05), and the proportion of agreement within the reference range (±1) was 100%. A reliable performance analysis template has been developed for the assessment of amateur boxing performance and is available for use by researchers, coaches and athletes to classify and quantify the movement characteristics of amateur boxing.

  20. Reliability performance of standby equipment with periodic testing

    International Nuclear Information System (INIS)

    Sim, S.H.

    1985-11-01

    In this report, the reliability performance of standby equipment subjected to periodic testing is studied. analytical expressions have been derived for reliability measures, such as the man accumulated operating time to failure, the expected number of tests between two consecutive failures, the mean time to failure following an emergency start-up and the probability of failing to complete an emergency mission of a specified duration. These results are useful for the reliability assessment of standby equipment such as combustion turbine units of the emergency power supply system, and of the Class III power system at a nuclear generating station

  1. Radiation protection - Performance criteria for radiobioassay. Part 1: General principles

    International Nuclear Information System (INIS)

    2001-01-01

    International Standard ISO 12790-1 was prepared by Technical Committee ISO/TC 85, Nuclear energy, Subcommittee SC 2, Radiation protection. ISO 12790 consists of the following parts, under the general title Radiation protection - Performance criteria for radiobioassay: Part 1: General principles; and Part 2: Rationale and specific applications This part of ISO 12790 provides criteria for quality assurance and control, evaluation of performance and the accreditation of radiobioassay service laboratories. Criteria and guidance for direct radiobioassay ( in vivo) and indirect radiobioassay ( in vitro) are given in separate clauses of this part of ISO 12790. This part of ISO 12790 addresses: a) the accuracy of direct ( in vivo) measurements of activity and quantities of selected important radionuclides in test phantoms and indirect ( in vitro) measurements of activity and quantities of selected important radionuclides in test samples; b) methods for determining the minimum detectable amount; c) minimum testing levels and testing ranges; d) requirements for reporting radiobioassay results by service laboratories; e) quality assurance in service laboratories; f) quality control in service laboratories; g) protocol for reporting test evaluations by service laboratories to the testing laboratory; h) default procedures when the service laboratory customer does not specify the performance criteria. The scope of this part of ISO 12790 does not include: a) detailed radiochemical methods for separating radionuclides from biological samples; b) detailed procedures for in vivo and in vitro radioactivity measurements; c) metabolic data and mathematical models for converting radiobioassay results into absorbed dose and dose equivalent; d) procedures for the preparation and distribution of test samples and phantoms by the testing laboratories. Analytical methods for radiobioassay are not currently standardized, but are available in the literature. Guidance for converting

  2. The Effects of Performance-Based Assessment Criteria on Student Performance and Self-Assessment Skills

    Science.gov (United States)

    Fastre, Greet Mia Jos; van der Klink, Marcel R.; van Merrienboer, Jeroen J. G.

    2010-01-01

    This study investigated the effect of performance-based versus competence-based assessment criteria on task performance and self-assessment skills among 39 novice secondary vocational education students in the domain of nursing and care. In a performance-based assessment group students are provided with a preset list of performance-based…

  3. Flash memories economic principles of performance, cost and reliability optimization

    CERN Document Server

    Richter, Detlev

    2014-01-01

    The subject of this book is to introduce a model-based quantitative performance indicator methodology applicable for performance, cost and reliability optimization of non-volatile memories. The complex example of flash memories is used to introduce and apply the methodology. It has been developed by the author based on an industrial 2-bit to 4-bit per cell flash development project. For the first time, design and cost aspects of 3D integration of flash memory are treated in this book. Cell, array, performance and reliability effects of flash memories are introduced and analyzed. Key performance parameters are derived to handle the flash complexity. A performance and array memory model is developed and a set of performance indicators characterizing architecture, cost and durability is defined.   Flash memories are selected to apply the Performance Indicator Methodology to quantify design and technology innovation. A graphical representation based on trend lines is introduced to support a requirement based pr...

  4. Performance Criteria for Capture and/or Immobilization Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Jubin, R. T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bruffey, S. H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Strachan, D. M. [Strata-G, LLC, Knoxville, TN (United States); Soelberg, N. R. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Spencer, B. B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Riley, B. J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-01

    The capture and subsequent immobilization of the four volatile radionuclides (3H, 14C, 85Kr, and 129I) from the off-gas streams of a used nuclear fuel reprocessing facility has been a topic of substantial research interest for the US DOE and international colleagues. Regulations set forth by the US EPA direct that some or all of these radionuclides (based upon fuel burnup, fuel type, cooling time, etc.) will require removal, to some extent, from the plant effluent streams prior to discharge to the environment. Upon removal, the radionuclide, as well as any associated sorbent, is destined for waste. Research of separation and capture methodologies has included a wide range of technologies including liquid caustic scrubbing systems, solid adsorbents, and cryogenic distillation. The studies of waste forms have been correspondingly diverse. In considering the technologies available for future development and implementation of both sorbents and waste forms, it will be necessary to use benchmarked measures of performance to objectively evaluate each sorbent system or waste form. This document is intended to provide initial guidance on the types of performance criteria for capture materials and waste forms intended for use in the recycling removal and disposal of UNF and, where possible, the minimum acceptable values for those criteria.

  5. Performance criteria for emergency medicine residents: a job analysis.

    Science.gov (United States)

    Blouin, Danielle; Dagnone, Jeffrey Damon

    2008-11-01

    A major role of admission interviews is to assess a candidate's suitability for a residency program. Structured interviews have greater reliability and validity than do unstructured ones. The development of content for a structured interview is typically based on the dimensions of performance that are perceived as important to succeed in a particular line of work. A formal job analysis is normally conducted to determine these dimensions. The dimensions essential to succeed as an emergency medicine (EM) resident have not yet been studied. We aimed to analyze the work of EM residents to determine these essential dimensions. The "critical incident technique" was used to generate scenarios of poor and excellent resident performance. Two reviewers independently read each scenario and labelled the performance dimensions that were reflected in each. All labels assigned to a particular scenario were pooled and reviewed again until a consensus was reached. Five faculty members (25% of our total faculty) comprised the subject experts. Fifty-one incidents were generated and 50 different labels were applied. Eleven dimensions of performance applied to at least 5 incidents. "Professionalism" was the most valued performance dimension, represented in 56% of the incidents, followed by "self-confidence" (22%), "experience" (20%) and "knowledge" (20%). "Professionalism," "self-confidence," "experience" and "knowledge" were identified as the performance dimensions essential to succeed as an EM resident based on our formal job analysis using the critical incident technique. Performing a formal job analysis may assist training program directors with developing admission interviews.

  6. Performance and Reliability of Wind Turbines: A Review

    Directory of Open Access Journals (Sweden)

    Sebastian Pfaffel

    2017-11-01

    Full Text Available Performance (availability and yield and reliability of wind turbines can make the difference between success and failure of wind farm projects and these factors are vital to decrease the cost of energy. During the last years, several initiatives started to gather data on the performance and reliability of wind turbines on- and offshore and published findings in different journals and conferences. Even though the scopes of the different initiatives are similar, every initiative follows a different approach and results are therefore difficult to compare. The present paper faces this issue, collects results of different initiatives and harmonizes the results. A short description and assessment of every considered data source is provided. To enable this comparison, the existing reliability characteristics are mapped to a system structure according to the Reference Designation System for Power Plants (RDS-PP®. The review shows a wide variation in the performance and reliability metrics of the individual initiatives. Especially the comparison on onshore wind turbines reveals significant differences between the results. Only a few publications are available on offshore wind turbines and the results show an increasing performance and reliability of offshore wind turbines since the first offshore wind farms were erected and monitored.

  7. Enhancing the role of MC and A through performance criteria

    International Nuclear Information System (INIS)

    Emeigh, C.W.; Smith, B.W.; Ehinger, M.H.

    1987-01-01

    Nuclear material safeguards combines physical protection and material control and accounting (MCandA). Integration of these measures to optimize protection requires defining the role of each in the context of the potential threats. The NRC amended 10 CFR Parts 70 and 74 to reform the MCandA regulations. The Reform Amendments specify insider threats to protect against and the general goals for detection, response and assurance. The Reform Amendments use the graded safeguards concept and are performance oriented. They allow a facility flexibility in determining how to meet the goals. An element of the Reform Amendments is the use of process monitoring data to account for nuclear materials in-process. This paper reviews the evolution of the Reform Amendments and identifies some of the decisions to implement performance criteria

  8. Material and design considerations of FBGA reliability performance

    International Nuclear Information System (INIS)

    Lee, Teck Kheng; Ng, T.C.; Chai, Y.M.

    2004-01-01

    FBGA package reliability is usually assessed through the conventional approaches of die attach and mold compound material optimization. However, with the rapid changes and fast-moving pace of electronic packaging and the introduction of new soldermask and core materials, substrate design has also become a critical factor in determining overall package reliability. The purpose of this paper is to understand the impact design and soldermask material of a rigid substrate on overall package reliability. Three different soldermask patterns with a matrix of different die attach, mold compound, and soldermask materials are assessed using the moisture sensitivity test (MST). Package reliability is also assessed through the use of temperature cycling (T/C) at conditions 'B' and 'C'. For material optimization, three different mold compounds and die attach materials are used. Material adhesion between different die attach materials and soldermask materials are obtained through die shear performed at various temperatures and preset moisture conditions. A study correlating the different packaging material properties and their relative adhesion strengths with overall package reliability in terms of both MST and T/C performance was performed. Soldermask design under the die pads was found to affect package reliability. For example, locating vias at the edge of the die is not desirable because the vias acts as initiation point for delamination and moisture-induced failure. Through die shear testing, soldermask B demonstrated higher adhesion properties compared to soldermask A across several packaging materials and enhanced the overall package reliability in terms of both MST and T/C performance. Both MST JEDEC level 1 and the T/C of 'B' and 'C' at 1000 cycles have been achieved through design and package material optimization

  9. Material and design considerations of FBGA reliability performance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Teck Kheng; Ng, T.C.; Chai, Y.M

    2004-09-01

    FBGA package reliability is usually assessed through the conventional approaches of die attach and mold compound material optimization. However, with the rapid changes and fast-moving pace of electronic packaging and the introduction of new soldermask and core materials, substrate design has also become a critical factor in determining overall package reliability. The purpose of this paper is to understand the impact design and soldermask material of a rigid substrate on overall package reliability. Three different soldermask patterns with a matrix of different die attach, mold compound, and soldermask materials are assessed using the moisture sensitivity test (MST). Package reliability is also assessed through the use of temperature cycling (T/C) at conditions 'B' and 'C'. For material optimization, three different mold compounds and die attach materials are used. Material adhesion between different die attach materials and soldermask materials are obtained through die shear performed at various temperatures and preset moisture conditions. A study correlating the different packaging material properties and their relative adhesion strengths with overall package reliability in terms of both MST and T/C performance was performed. Soldermask design under the die pads was found to affect package reliability. For example, locating vias at the edge of the die is not desirable because the vias acts as initiation point for delamination and moisture-induced failure. Through die shear testing, soldermask B demonstrated higher adhesion properties compared to soldermask A across several packaging materials and enhanced the overall package reliability in terms of both MST and T/C performance. Both MST JEDEC level 1 and the T/C of 'B' and 'C' at 1000 cycles have been achieved through design and package material optimization.

  10. Operators work reliability current control based on the psychological and physiological criteria

    International Nuclear Information System (INIS)

    Karpenko, A.V.; Burov, A.Yu.; Grigorus', A.G.; Kal'nish, V.V.; Kapshuk, A.P.; Grigor'yants, T.N.; Bobko, N.A.

    1984-01-01

    A possibility of developing highly sensitive criteria for assessment of mental working ability at the expense of profound automated analysis of available psychological and physiological criteria is disclosed; it is a precondition for developing operator is woAking ability control system not requiring additional personnel for its operation

  11. Reliability-based performance simulation for optimized pavement maintenance

    International Nuclear Information System (INIS)

    Chou, Jui-Sheng; Le, Thanh-Son

    2011-01-01

    Roadway pavement maintenance is essential for driver safety and highway infrastructure efficiency. However, regular preventive maintenance and rehabilitation (M and R) activities are extremely costly. Unfortunately, the funds available for the M and R of highway pavement are often given lower priority compared to other national development policies, therefore, available funds must be allocated wisely. Maintenance strategies are typically implemented by optimizing only the cost whilst the reliability of facility performance is neglected. This study proposes a novel algorithm using multi-objective particle swarm optimization (MOPSO) technique to evaluate the cost-reliability tradeoff in a flexible maintenance strategy based on non-dominant solutions. Moreover, a probabilistic model for regression parameters is employed to assess reliability-based performance. A numerical example of a highway pavement project is illustrated to demonstrate the efficacy of the proposed MOPSO algorithms. The analytical results show that the proposed approach can help decision makers to optimize roadway maintenance plans. - Highlights: →A novel algorithm using multi-objective particle swarm optimization technique. → Evaluation of the cost-reliability tradeoff in a flexible maintenance strategy. → A probabilistic model for regression parameters is employed to assess reliability-based performance. → The proposed approach can help decision makers to optimize roadway maintenance plans.

  12. Reliability-based performance simulation for optimized pavement maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Jui-Sheng, E-mail: jschou@mail.ntust.edu.tw [Department of Construction Engineering, National Taiwan University of Science and Technology (Taiwan Tech), 43 Sec. 4, Keelung Rd., Taipei 106, Taiwan (China); Le, Thanh-Son [Department of Construction Engineering, National Taiwan University of Science and Technology (Taiwan Tech), 43 Sec. 4, Keelung Rd., Taipei 106, Taiwan (China)

    2011-10-15

    Roadway pavement maintenance is essential for driver safety and highway infrastructure efficiency. However, regular preventive maintenance and rehabilitation (M and R) activities are extremely costly. Unfortunately, the funds available for the M and R of highway pavement are often given lower priority compared to other national development policies, therefore, available funds must be allocated wisely. Maintenance strategies are typically implemented by optimizing only the cost whilst the reliability of facility performance is neglected. This study proposes a novel algorithm using multi-objective particle swarm optimization (MOPSO) technique to evaluate the cost-reliability tradeoff in a flexible maintenance strategy based on non-dominant solutions. Moreover, a probabilistic model for regression parameters is employed to assess reliability-based performance. A numerical example of a highway pavement project is illustrated to demonstrate the efficacy of the proposed MOPSO algorithms. The analytical results show that the proposed approach can help decision makers to optimize roadway maintenance plans. - Highlights: > A novel algorithm using multi-objective particle swarm optimization technique. > Evaluation of the cost-reliability tradeoff in a flexible maintenance strategy. > A probabilistic model for regression parameters is employed to assess reliability-based performance. > The proposed approach can help decision makers to optimize roadway maintenance plans.

  13. NWTS program criteria for mined geologic disposal of nuclear waste: repository performance and development criteria. Public draft

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-07-01

    This document, DOE/NWTS-33(3) is one of a series of documents to establish the National Waste Terminal Storage (NWTS) program criteria for mined geologic disposal of high-level radioactive waste. For both repository performance and repository development it delineates the criteria for design performance, radiological safety, mining safety, long-term containment and isolation, operations, and decommissioning. The US Department of Energy will use these criteria to guide the development of repositories to assist in achieving performance and will reevaluate their use when the US Nuclear Regulatory Commission issues radioactive waste repository rules.

  14. NWTS program criteria for mined geologic disposal of nuclear waste: repository performance and development criteria. Public draft

    International Nuclear Information System (INIS)

    1982-07-01

    This document, DOE/NWTS-33(3) is one of a series of documents to establish the National Waste Terminal Storage (NWTS) program criteria for mined geologic disposal of high-level radioactive waste. For both repository performance and repository development it delineates the criteria for design performance, radiological safety, mining safety, long-term containment and isolation, operations, and decommissioning. The US Department of Energy will use these criteria to guide the development of repositories to assist in achieving performance and will reevaluate their use when the US Nuclear Regulatory Commission issues radioactive waste repository rules

  15. Developing safety performance functions incorporating reliability-based risk measures.

    Science.gov (United States)

    Ibrahim, Shewkar El-Bassiouni; Sayed, Tarek

    2011-11-01

    Current geometric design guides provide deterministic standards where the safety margin of the design output is generally unknown and there is little knowledge of the safety implications of deviating from these standards. Several studies have advocated probabilistic geometric design where reliability analysis can be used to account for the uncertainty in the design parameters and to provide a risk measure of the implication of deviation from design standards. However, there is currently no link between measures of design reliability and the quantification of safety using collision frequency. The analysis presented in this paper attempts to bridge this gap by incorporating a reliability-based quantitative risk measure such as the probability of non-compliance (P(nc)) in safety performance functions (SPFs). Establishing this link will allow admitting reliability-based design into traditional benefit-cost analysis and should lead to a wider application of the reliability technique in road design. The present application is concerned with the design of horizontal curves, where the limit state function is defined in terms of the available (supply) and stopping (demand) sight distances. A comprehensive collision and geometric design database of two-lane rural highways is used to investigate the effect of the probability of non-compliance on safety. The reliability analysis was carried out using the First Order Reliability Method (FORM). Two Negative Binomial (NB) SPFs were developed to compare models with and without the reliability-based risk measures. It was found that models incorporating the P(nc) provided a better fit to the data set than the traditional (without risk) NB SPFs for total, injury and fatality (I+F) and property damage only (PDO) collisions. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Proceedings of the 1998 Photovoltaic Performance and Reliability Workshop

    International Nuclear Information System (INIS)

    Kroposki, B.

    1998-01-01

    This proceedings is the compilation of all papers presented at the 11th PV Performance and Reliability Workshop held at the Doubletree Hotel in Cocoa Beach, Florida, on November 3-5, 1998. The workshop was hosted by the Florida Solar Energy Center. This year's workshop included presentations from 29 speakers and had 110 attendees

  17. Developing a system engineering program to improve performance and reliability

    International Nuclear Information System (INIS)

    Keuter, D.

    1985-01-01

    After several maintenance, operational, and equipment problems last year, Trojan set out on a mission to improve plant performance and reliability by strengthening its on-site engineering organization. This paper presents Trojan's plans in developing an on-site system engineering organization

  18. Human performance for the success of equipment reliability programs

    International Nuclear Information System (INIS)

    Woodcock, J.

    2007-01-01

    Human performance is a critical element of programs directed at equipment reliability. Reliable equipment performance requires broad support from all levels of plant management and throughout all plant departments. Experience at both nuclear power plants and fuel manufacturing plants shows that human performance must be addressed during all phases of program implementation from the beginning through the establishment of a living, on-going process. At the beginning, certain organizational and management actions during the initiation of the program set the stage for successful adoption by station personnel, leading to more rapid benefits. For the long term, equipment reliability is a living process needed throughout the lifetime of a station, a program which must be motivated and measured. Sustained acceptance and participation by the plant personnel is a requirement, and culture is a key ingredient. This paper will provide an overview of key human performance issues to be considered, using the application of the INPO AP-913 Equipment Reliability Guideline as a basis and gives some best practices for training, communicating and implementing programs. The very last part includes ways to tell if the program is effective

  19. Reliable and Valid Assessment of Clinical Bronchoscopy Performance

    DEFF Research Database (Denmark)

    Konge, Lars; Larsen, Klaus Richter; Clementsen, Paul

    2012-01-01

    : The interrater reliability was high, with Cronbach's a = 0.86. Assessment of 3 bronchoscopies by a single rater had a generalizability coefficient of 0.84. The correlation between experience and performance was good (Pearson correlation = 0.76). There were significant differences between the groups for all...

  20. Reliability and performance evaluation of stainless and mild steel ...

    African Journals Online (AJOL)

    Reliability and performance of stainless and mild steel products in methanolic and aqueous sodium chloride media have been investigated. Weight-loss and pre-exposure methods were used. There was a higher rate of weight-loss of mild steels and stainless steels in 1% HCl methanolic solution than in aqueous NaCl ...

  1. Conventional Versus Rosemont Endoscopic Ultrasound Criteria for Chronic Pancreatitis: Comparing Interobserver Reliability and Intertest Agreement

    Directory of Open Access Journals (Sweden)

    Bruce Kalmin

    2011-01-01

    Full Text Available BACKGROUND: The Rosemont criteria (RC were recently proposed by expert consensus to standardize endoscopic ultrasound (EUS features and thresholds for diagnosing chronic pancreatitis (CP; however, they are cumbersome and are not validated.

  2. MHA admission criteria and program performance: do they predict career performance?

    Science.gov (United States)

    Porter, J; Galfano, V J

    1987-01-01

    The purpose of this study was to determine to what extent admission criteria predict graduate school and career performance. The study also analyzed which objective and subjective criteria served as the best predictors. MHA graduates of the University of Minnesota from 1974 to 1977 were surveyed to assess career performance. Student files served as the data base on admission criteria and program performance. Career performance was measured by four variables: total compensation, satisfaction, fiscal responsibility, and level of authority. High levels of MHA program performance were associated with women who had high undergraduate GPAs from highly selective undergraduate colleges, were undergraduate business majors, and participated in extracurricular activities. High levels of compensation were associated with relatively low undergraduate GPAs, high levels of participation in undergraduate extracurricular activities, and being single at admission to graduate school. Admission to MHA programs should be based upon both objective and subjective criteria. Emphasis should be placed upon the selection process for MHA students since admission criteria are shown to explain 30 percent of the variability in graduate program performance, and as much as 65 percent of the variance in level of position authority.

  3. Thermal performance envelopes for MHTGRs - Reliability by design

    International Nuclear Information System (INIS)

    Etzel, K.T.; Howard, W.W.; Zgliczynski, J.

    1992-01-01

    Thermal performance envelopes are used to specify steady-state design requirements for the systems of the modular high-temperature gas-cooled reactor (MHTGR) to maximize plant performance reliability with optimized design. The thermal performance envelopes are constructed around the expected operating point to account for uncertainties in actual plant as-built parameters and plant operation. The components are then designed to perform successfully at all points within the envelope. As a result, plant reliability is maximized by accounting for component thermal performance variation in the design. The design is optimized by providing a means to determine required margins in a disciplined and visible fashion. This is accomplished by coordinating these requirements with the various system and component designers in the early stages of the design, applying the principles of total quality management. The design is challenged by the more complex requirements associated with a range of operating conditions, but in return, high probability of delivering reliable performance throughout the plant life is ensured

  4. Performance Criteria of Spatial Development Projects Based on Interregional Integration

    Directory of Open Access Journals (Sweden)

    Elena Viktorovna Kurushina

    2018-03-01

    Full Text Available The search of efficient ways for the development of regional socio-economic space is a relevant problem. The authors consider the models of spatial organization according to the Spatial Development Strategy of the Russian Federation until 2030. We conduct the comparative analysis of scenarios for the polarized and diversified spatial growth. Many investigations consider the concepts of polarized and endogenous growth. This study proposes a methodology to assess the development of macroregions and to increase the viability of interregional integration projects. To develop this methodology, we formulate scientific principles and indirect criteria of the project performance conforming to the theory of regional integration. In addition to the territorial community and complementarity of the development potentials, regional integration in the country should be based on the principles of security, networking, limited quantity and awareness of the potential project participants. Integration should ensure synergetic effects and take into account cultural and historical closeness, that manifests in the common mentality and existing economic relations among regions. The calculation results regarding the indirect criteria are obtained using the methods of classification and spatial correlation. This study confirms the hypothesis, that the formation of the Western Siberian and Ural macro-regions is appropriate. We have concluded this on the basis of the criteria of economic development, economic integration, the similarity of regional spaces as habitats, and a number of participants for the subjects of the Ural Federal District. The projection of the patterns of international economic integration to the interregional level allows predicting the highest probability for the successful cooperation among the Western Siberian regions with a high level of economic development. The authors’ method has revealed a high synchronization between the economies of

  5. NWTS program criteria for mined geologic disposal of nuclear waste: program objectives, functional requirements, and system performance criteria

    International Nuclear Information System (INIS)

    1982-03-01

    The NWTS-33 series, of which this document is a part, provides guidance for the National Waste Terminal Storage (NWTS) program in the development and implementation of licensed mined geologic disposal systems for solidified high-level and TRU wastes. Program objectives, functional requirements, and system performance criteria are found in this document. At the present time final criteria have not been issued by the Nuclear Regulatory Commission (NRC) and Environmental Protection Agency (EPA). The criteria in these documents have been developed on the basis of DOE's judgment of what is required to protect the health and safety of the public and the quality of the environment. It is expected that these criteria will be consistent with regulatory standards. The criteria will be re-evaluated on a periodic basis to ensure that they remain consistent with national waste management policy and regulatory requirements. A re-evaluation will be made when final criteria are promulgated by the NRC and EPA. A background section that briefly describes the mined geologic disposal system and explains the hierarchy and application of the NWTS criteria is included in Section 2.0. Secton 3.0 presents the program objectives, Section 4.0 functional requirements, Secton 5.0 the system performance criteria, and Section 6.0 quality assurance and standards. A draft of this document was issued for public comment in April 1981. Appendix A contains the DOE responses to the comments received. Appendix B is a glossary

  6. The effects of performance-based assessment criteria on student performance and self-assessment skills

    NARCIS (Netherlands)

    Fastré, Greet; Van der Klink, Marcel; Van Merriënboer, Jeroen

    2010-01-01

    Fastré, G. M. J., Van der Klink, M. R., & Van Merriënboer, J. J. G. (2010). The effects of performance-based assessment criteria on student performance and self-assessment skills. Advances in Health Science Education, 15(4), 517-532.

  7. Labs21 environmental performance criteria Version 2.0

    Energy Technology Data Exchange (ETDEWEB)

    Mathew, Paul A.

    2002-10-01

    Laboratory facilities present a unique challenge for energy efficient and sustainable design, with their inherent complexity of systems, health and safety requirements, long-term flexibility and adaptability needs, energy use intensity, and environmental impacts. The typical laboratory is about five times as energy intensive as a typical office building and costs about three times as much per unit area. The Labs21 Environmental Performance Criteria (EPC) is a rating system for use by laboratory building project stakeholders to assess the environmental performance of laboratory facilities. Currently, the U.S. Green Building Council's LEED{trademark} Rating System is the primary tool used. However, LEED{trademark} was designed for U.S. commercial office buildings and as such, lacks some attributes essential to the sustainable design of this unique and complex building type. To facilitate widespread use and to avoid ''re-inventing the wheel'' this effort builds on the existing LEED{trademark} Rating System 2.0.

  8. Criteria of ‘authenticity’ in traditional Georgian musical performance

    Directory of Open Access Journals (Sweden)

    Gabisonia Tamaz

    2014-01-01

    Full Text Available Today we often use term ‘authentic’ in relation to different appearances of Georgian folk music. Along with the unambiguous meaning ‘real’ this term also has other meanings: ‘ethnic’, ‘rural’, ‘old’, ‘function of usual environment’, ‘traditional-stylistic’, ‘authoritative’, or ‘reproductive’. In spite of some interconnections that arise from the term ‘authentic’ and its other meanings, the most relevant way to apply this popular term for performers and audiences of ‘real folklore’ is traditionality. This factor is manifested in the following contexts: a performer (receiver and distributor of tradition, unobtrusively and orally, b motivation/function (representative and spontaneous function, hereditary, utilitarian and aesthetic-daily motivation, c repertoire (compliance of musical and verbal text’s sample with its social function, eluding canonized versions, d expression (adequate articulation, performing regulation which is not determined by the stage, traditional instrument etc.. The problem of authenticity is more successfully regulated in traditional Georgian church music than in folk music. For the latter, in this regard the special difficulty is caused by identification of modern trends that contain folk motifs. The most popular among them is distinctive, with its stylistic reminiscent layer from the Eastern Georgian Mountains, which we refer as ‘para-folkore’. Notwithstanding the fact that Georgian folklore is not centrally authorized, modernization of folklore samples and also those manifestations of post-folklore that are further away from the traditional motifs attract a wide range of listeners. Essentially, the meaning of ‘authentic’ in the Georgian ethno-musical context is presented as performance of the traditional rural repertoire with traditional articulation. However, we think that it is convenient for the criteria of traditional, usual environment to be added to this

  9. 78 FR 38735 - Autopsy Performance Criteria: Standards, Guidelines and Best Practices

    Science.gov (United States)

    2013-06-27

    ... DEPARTMENT OF JUSTICE Office of Justice Programs [OJP (NIJ) Docket No. 1626] Autopsy Performance Criteria: Standards, Guidelines and Best Practices AGENCY: National Institute of Justice, DOJ. ACTION... entitled, ``Autopsy Performance Criteria: Standards, Guidelines and Best Practices''. The opportunity to...

  10. System reliability, performance and trust in adaptable automation.

    Science.gov (United States)

    Chavaillaz, Alain; Wastell, David; Sauer, Jürgen

    2016-01-01

    The present study examined the effects of reduced system reliability on operator performance and automation management in an adaptable automation environment. 39 operators were randomly assigned to one of three experimental groups: low (60%), medium (80%), and high (100%) reliability of automation support. The support system provided five incremental levels of automation which operators could freely select according to their needs. After 3 h of training on a simulated process control task (AutoCAMS) in which the automation worked infallibly, operator performance and automation management were measured during a 2.5-h testing session. Trust and workload were also assessed through questionnaires. Results showed that although reduced system reliability resulted in lower levels of trust towards automation, there were no corresponding differences in the operators' reliance on automation. While operators showed overall a noteworthy ability to cope with automation failure, there were, however, decrements in diagnostic speed and prospective memory with lower reliability. Copyright © 2015. Published by Elsevier Ltd.

  11. Design Optimization Method for Composite Components Based on Moment Reliability-Sensitivity Criteria

    Science.gov (United States)

    Sun, Zhigang; Wang, Changxi; Niu, Xuming; Song, Yingdong

    2017-08-01

    In this paper, a Reliability-Sensitivity Based Design Optimization (RSBDO) methodology for the design of the ceramic matrix composites (CMCs) components has been proposed. A practical and efficient method for reliability analysis and sensitivity analysis of complex components with arbitrary distribution parameters are investigated by using the perturbation method, the respond surface method, the Edgeworth series and the sensitivity analysis approach. The RSBDO methodology is then established by incorporating sensitivity calculation model into RBDO methodology. Finally, the proposed RSBDO methodology is applied to the design of the CMCs components. By comparing with Monte Carlo simulation, the numerical results demonstrate that the proposed methodology provides an accurate, convergent and computationally efficient method for reliability-analysis based finite element modeling engineering practice.

  12. ACCURACY AND RELIABILITY AS CRITERIA OF INFORMATIVENESS IN THE NEWS STORY

    Directory of Open Access Journals (Sweden)

    Melnikova Ekaterina Aleksandrovna

    2014-12-01

    Full Text Available The article clarifies the meaning of the terms accuracy and reliability of the news story, offers a researcher's approach to obtaining objective data that helps to verify linguistic means of accuracy and reliability presence in the informative structure of the text. The accuracy of the news story is defined as a high relevance degree of event reflection through language representation of its constituents; the reliability is viewed as news story originality that is proved by introducing citations and sources of information considered being trustworthy into the text content. Having based the research on an event nominative density identification method, the author composed nominative charts of 115 news story texts, collected at web-sites of BBC and CNN media corporations; distinguished qualitative and quantitative markers of accuracy and reliability in the news story text; confirmed that the accuracy of the news story is achieved with terminological clearness in nominating event constituents in the text, thematic bind between words, presence of onyms that help deeply identify characteristics of the referent event. The reliability of the text is discovered in eyewitness accounts, quotations, and references to the sources being considered as trustworthy. Accurate revision of associations between accuracy and reliability and informing strategies in digital news nets allowed the author to set two variants of information delivery, that differ in their communicative and pragmatic functions: developing (that informs about major and minor details of an event and truncated (which gives some details thus raising the interest to the event and urging a reader to open a full story.

  13. Performance objectives and criteria for conducting DOE environmental audits

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-01-01

    This document contains the Performance Objectives and Criteria (POC) that have been developed for environmental audits and assessments conducted by the Office of the Assistant Secretary for Environment, Safety and Health. The Environmental POC can serve multiple purposes. Primarily, they are to serve as guidelines for the technical specialists conducted the audits and assessments, and for the team management. The POC can also serve as supporting documents for training of technical discipline specialists and Team Leaders and as bases for DOE programs and field offices and contractors conducting audit or assessment activities or improving environmental protection programs. It must be recognized that not all of the POC will necessarily apply to all DOE facilities. The users of this document must rely upon their knowledge of the facility and their professional judgment, or the judgment of qualified environmental professionals to determine the applicability of each POC. The POC cover eleven technical disciplines: air; surface water and drinking water quality; groundwater; waste management; toxic and chemical materials; radiation; quality assurance; inactive waste sites and releases; ecological and cultural resources; the National Environmental Policy Act (NEPA); and environmental management systems.

  14. Performance objectives and criteria for conducting DOE environmental audits

    International Nuclear Information System (INIS)

    1994-01-01

    This document contains the Performance Objectives and Criteria (POC) that have been developed for environmental audits and assessments conducted by the Office of the Assistant Secretary for Environment, Safety and Health. The Environmental POC can serve multiple purposes. Primarily, they are to serve as guidelines for the technical specialists conducted the audits and assessments, and for the team management. The POC can also serve as supporting documents for training of technical discipline specialists and Team Leaders and as bases for DOE programs and field offices and contractors conducting audit or assessment activities or improving environmental protection programs. It must be recognized that not all of the POC will necessarily apply to all DOE facilities. The users of this document must rely upon their knowledge of the facility and their professional judgment, or the judgment of qualified environmental professionals to determine the applicability of each POC. The POC cover eleven technical disciplines: air; surface water and drinking water quality; groundwater; waste management; toxic and chemical materials; radiation; quality assurance; inactive waste sites and releases; ecological and cultural resources; the National Environmental Policy Act (NEPA); and environmental management systems

  15. Toward Real-time Multi-criteria Decision Making for Bus Service Reliability Optimisation

    DEFF Research Database (Denmark)

    Tran, Vu The; Eklund, Peter; Cook, Chris

    2015-01-01

    factors (such as traffic congestion and bad weather) in high frequency transit operations often cause irregular headway that can result in decreased service reliability. The approach proposed in this paper, which has the capability of handling the uncertainty of transit operations based on Multi...

  16. The impact of multi-criteria performance measurement on business performance improvement

    OpenAIRE

    Kasie, Fentahun Moges; Belay, Alemu Moges

    2013-01-01

    Purpose: The purpose of this paper is to investigate the relationship between multi-criteria performance measurement (MCPM) practice and business performance improvement using the raw data collected from 33 selected manufacturing companies. In addition, it proposes modified MCPM model as an effective approach to improve business performance of manufacturing companies. Design/methodology/approach:Research paper. Primary and secondary data were collected using questionnaire survey, interview an...

  17. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  18. Basic considerations for the preparation of performance testing materials as related to performance evaluation acceptance criteria

    International Nuclear Information System (INIS)

    McCurdy, D.E.; Morton, J.S.

    2001-01-01

    The preparation of performance testing (PT) materials for environmental and radiobioassay applications involves the use of natural matrix materials containing the analyte of interest, the addition (spiking) of the analyte to a desired matrix (followed by blending for certain matrices) or a combination of the two. The distribution of the sample analyte concentration in a batch of PT samples will reflect the degree of heterogeneity of the analyte in the PT material and/or the reproducibility of the sample preparation process. Commercial and government implemented radioanalytical performance evaluation programs have a variety of acceptable performance criteria. The performance criteria should take into consideration many parameters related to the preparation of the PT materials including the within and between sample analyte heterogeneity, the accuracy of the quantification of an analyte in the PT material and to what 'known' value will a laboratory's result be compared. How sample preparation parameters affect the successful participation in performance evaluation (PE) programs having an acceptance criteria established as a percent difference from a 'known' value or in PE programs using other acceptance criteria, such as the guidance provided in ANSI N42.22 and N13.30 is discussed. (author)

  19. Photovoltaic Reliability Performance Model v 2.0

    Energy Technology Data Exchange (ETDEWEB)

    2016-12-16

    PV-RPM is intended to address more “real world” situations by coupling a photovoltaic system performance model with a reliability model so that inverters, modules, combiner boxes, etc. can experience failures and be repaired (or left unrepaired). The model can also include other effects, such as module output degradation over time or disruptions such as electrical grid outages. In addition, PV-RPM is a dynamic probabilistic model that can be used to run many realizations (i.e., possible future outcomes) of a system’s performance using probability distributions to represent uncertain parameter inputs.

  20. A view on the ways design of reliability criteria in structural mechanics

    International Nuclear Information System (INIS)

    Kopecky, M.

    2005-01-01

    Contemporary intensive development of technology puts ever-increasing demands on the reliability of products. The increase in the reliability level is emphasised also in transport machines and equipment. This all requires a further improvement of the method of designing and strength checking of a construction. The methods described in this paper are the ways to reach the solution goals with the maximum use of computer technology. A practical example of loading system analysis in presented which demonstrates use the special instrument to measurement of distribution the force and torsion moment in card an-joint for control purposes and uses the special instrument to generally measurement of distribution random loading parameter. The application of this methodology shortens knowledge of the time to failure of mobile machine components and contributes to the safety and economy of mechanical systems. The results of its application would be presented to mobile facility elements. (authors)

  1. Dynamic Performance Characteristic Tests of Real Scale Lead Rubber Bearing for the Evaluation of Performance Criteria

    International Nuclear Information System (INIS)

    Kim, Min Kyu; Kim, Jung-Han; Choi, In-Kil

    2014-01-01

    Dynamic characteristic tests of full scale lead rubber bearing were performed for the evaluation of performance criteria of isolation system for nuclear power plants. For the dynamic test for a full scale rubber bearing, two 1500mm diameter lead rubber bearings were manufactured. The viewpoints of this dynamic test are determination of an ultimate shear strain level of lead rubber bearing, behavior of rubber bearing according to static and dynamic input motion, sinusoidal and random (earthquake) motion, and 1-dimentional and 2-dimensional input motion. In this study, seismic isolation device tests were performed for the evaluation of performance criteria of isolation system. Through this test, it can be recognized that in the case of considering a mechanical property test, dynamic and multi degree of loading conditions should be determined. But these differences should be examined how much affect to the global structural behavior

  2. The SACADA database for human reliability and human performance

    International Nuclear Information System (INIS)

    James Chang, Y.; Bley, Dennis; Criscione, Lawrence; Kirwan, Barry; Mosleh, Ali; Madary, Todd; Nowell, Rodney; Richards, Robert; Roth, Emilie M.; Sieben, Scott; Zoulis, Antonios

    2014-01-01

    Lack of appropriate and sufficient human performance data has been identified as a key factor affecting human reliability analysis (HRA) quality especially in the estimation of human error probability (HEP). The Scenario Authoring, Characterization, and Debriefing Application (SACADA) database was developed by the U.S. Nuclear Regulatory Commission (NRC) to address this data need. An agreement between NRC and the South Texas Project Nuclear Operating Company (STPNOC) was established to support the SACADA development with aims to make the SACADA tool suitable for implementation in the nuclear power plants' operator training program to collect operator performance information. The collected data would support the STPNOC's operator training program and be shared with the NRC for improving HRA quality. This paper discusses the SACADA data taxonomy, the theoretical foundation, the prospective data to be generated from the SACADA raw data to inform human reliability and human performance, and the considerations on the use of simulator data for HRA. Each SACADA data point consists of two information segments: context and performance results. Context is a characterization of the performance challenges to task success. The performance results are the results of performing the task. The data taxonomy uses a macrocognitive functions model for the framework. At a high level, information is classified according to the macrocognitive functions of detecting the plant abnormality, understanding the abnormality, deciding the response plan, executing the response plan, and team related aspects (i.e., communication, teamwork, and supervision). The data are expected to be useful for analyzing the relations between context, error modes and error causes in human performance

  3. The Spanish version of the 2010 American College of Rheumatology Preliminary Diagnostic Criteria for fibromyalgia: reliability and validity assessment.

    Science.gov (United States)

    Casanueva, Benigno; García-Fructuoso, Ferrán; Belenguer, Rafael; Alegre, Cayetano; Moreno-Muelas, José V; Hernández, José L; Pina, Tinitario; González-Gay, Miguel Á

    2016-01-01

    To investigate the reliability and validity of the Spanish version of the 2010 American College of Rheumatology (ACR) Preliminary Diagnostic Criteria for Fibromyalgia (FM) in patients with chronic pain. The 2010 ACR Preliminary Diagnostic Criteria for FM were adapted to a Spanish version following the guidelines of the Rheumatology Spanish Society Study Group of FM. Based on the 1990 ACR classi cation criteria for FM, patients with chronic pain were initially divided into two groups: a FM group and another group of non-FM individuals. Patients from the FM group were evaluated by tender points (TP) examination, Fibromyalgia Impact Questionnaire (FIQ), Widespread Pain Index (WPI), and Symptom Severity Scale (SSS). The non-FM (control) group included patients with rheumatoid arthritis (RA) and osteoarthritis (OA). They were evaluated by WPI and SSS. We included 1,169 patients divided into two groups: FM group (n=803; 777 women and 26 men) and non-FM group (n= 366; 147 patients with RA, and 219 with OA). The median value of TP and FIQ in the FM group was 16 and 74 respectively. The preliminary 2010 ACR criteria were met by 665 (82.8%) FM patients and by 112 (30.6%) patients from the non-FM group (pFIQ (p<0.0001), WPI (p<0.0001) and SSS (p<0.0001) were observed when FM patients fulfilling the 2010 ACR criteria were compared with the remaining FM patients who did not fulfill these criteria. Sensitivity of the Spanish version of the 2010 ACR criteria was 85.6% (95%CI: 83.1-88.1), speci city 73.2% (95%CI: 68.4-78), positive predictive value 87.7% (95%CI: 85.3-90.1) and negative predictive value 69.4% (95%CI: 64.5-74.2). Our results indicate that the 2010 ACR Preliminary Diagnostic Criteria for FM may be useful to establish a diagnosis of FM in Spanish individuals with chronic pain.

  4. Reliability- and performance-based robust design optimization of MEMS structures considering technological uncertainties

    Science.gov (United States)

    Martowicz, Adam; Uhl, Tadeusz

    2012-10-01

    The paper discusses the applicability of a reliability- and performance-based multi-criteria robust design optimization technique for micro-electromechanical systems, considering their technological uncertainties. Nowadays, micro-devices are commonly applied systems, especially in the automotive industry, taking advantage of utilizing both the mechanical structure and electronic control circuit on one board. Their frequent use motivates the elaboration of virtual prototyping tools that can be applied in design optimization with the introduction of technological uncertainties and reliability. The authors present a procedure for the optimization of micro-devices, which is based on the theory of reliability-based robust design optimization. This takes into consideration the performance of a micro-device and its reliability assessed by means of uncertainty analysis. The procedure assumes that, for each checked design configuration, the assessment of uncertainty propagation is performed with the meta-modeling technique. The described procedure is illustrated with an example of the optimization carried out for a finite element model of a micro-mirror. The multi-physics approach allowed the introduction of several physical phenomena to correctly model the electrostatic actuation and the squeezing effect present between electrodes. The optimization was preceded by sensitivity analysis to establish the design and uncertain domains. The genetic algorithms fulfilled the defined optimization task effectively. The best discovered individuals are characterized by a minimized value of the multi-criteria objective function, simultaneously satisfying the constraint on material strength. The restriction of the maximum equivalent stresses was introduced with the conditionally formulated objective function with a penalty component. The yielded results were successfully verified with a global uniform search through the input design domain.

  5. Numerical simulations of crashworthiness performance of multi-cell structures considering damage evolution criteria

    Directory of Open Access Journals (Sweden)

    Estrada Quirino

    2017-01-01

    Full Text Available In this paper finite element software Abaqus was used to analyse the effect of cross-sectional shape on the crashworthiness performance of multi-cell profiles. An emphasis was placed on the modelling of the damage initiation criteria and its evolution during the crash event. The structures evaluated included square and circular multi-cell cross-sections fabricated with aluminium alloy EN AW-7108 T6. During the crash simulations, the structures were subjected to axial impact loads using a 500-kg rigid body striker with an initial velocity of 10 m/s. Accordingly to our results, profiles with circular cross-section base presented better crashworthiness performance than square profiles. An increase in crush force efficiency to 36.9% and specific energy to 35.4% was observed when a circular cross-section has been reinforced in the transversal and longitudinal directions. Finally, it was corroborated that the addition of the damage initiation criteria allowed for more reliable crash simulations of the structures.

  6. Impact of ANSI 2009 criteria for performance testing in TLD personnel monitoring

    International Nuclear Information System (INIS)

    MeenaI, P.; Rakesh, R.B.; Srivastava, Kshama; KoIambe, D.H.; Sapra, B.K.

    2014-01-01

    External Quality Assurance in TLD Personnel Monitoring Service was initiated in 1985, for periodic performance evaluation of various TLD Laboratories through postal exercise. Presently, all the 16 laboratories involved in Personnel Monitoring Service are covered under QA exercise. Since beginning, American National Standards Institute (ANSI) criteria have been adopted for performance testing in QA exercise. Presently, ANSI 2001 performance criteria along with ISO trumpet curve analysis method are being used for performance evaluation. In 2009, ANSI modified the performance evaluation criteria and this study evaluates its impact and feasibility of implementation of ANSI 2009 criteria in the quality assurance program for personnel monitoring. The performance of some laboratories evaluated using both ANSI 2001 and ANSI 2009 criteria have been discussed. The study shows that the ANSI 2009 criteria is more stringent and encourages even distribution of bias and standard deviation. This can be implemented with suitable modifications for performance evaluation

  7. Reliability performance testing of totally encapsulating chemical protective suits

    International Nuclear Information System (INIS)

    Johnson, J.S.; Swearengen, P.M.

    1991-01-01

    The need to assure a high degree of reliability for totally encapsulating chemical protective (TECP) suits has been recognized by Lawrence Livermore National Laboratory's (LLNL) Hazards Control Department for some time. The following four tests were proposed as necessary to provide complete evaluation of TECP suit performance: 1. Quantitative leak test (ASTM draft), 2. Worst-case chemical exposure test (conceptual), 3. Pressure leak-rate test (complete, ASTM F1057-87), and 4. Chemical leak-rate test (ASTM draft). This paper reports on these tests which should be applied to measuring TECP suit performance in two stages: design qualification tests and field use tests. Test 1, 2, and 3 are used as design qualification tests, and tests 3 and 4 are used as field use tests

  8. A Regulatory Perspective on the Performance and Reliability of Nuclear Passive Safety Systems

    International Nuclear Information System (INIS)

    Quan, Pham Trung; Lee, Sukho

    2016-01-01

    Passive safety systems have been proven to enhance the safety of NPPs. When an accident such as station blackout occurs, these systems can perform the following functions: the decay heat removal, passive safety injection, containment cooling, and the retention of radioactive materials. Following the IAEA definitions, using passive safety systems reduces reliance on active components to achieve proper actuation and not requiring operator intervention in accident conditions. That leads to the deviations in boundary conditions of the critical process or geometric parameters, which activate and operate the system to perform accident prevention and mitigation functions. The main difficulties in evaluation of functional failure of passive systems arise because of (a) lack of plant operational experience; (b) scarcity of adequate experimental data from integral test facilities or from separate effect tests in order to understand the performance characteristics of these passive systems, not only at normal operation but also during accidents and transients; (c) lack of accepted definitions of failure modes for these systems; and (d) difficulty in modeling certain physical behavior of these systems. Reliability assessment of the PSS is still one of the important issues. Several reliability methodologies such as REPAS, RMPS and ASPRA have been applied to the reliability assessments. However, some issues are remained unresolved due to lack of understanding of the treatment of dynamic failure characteristics of components of the PSS, the treatment of dynamic variation of independence process parameters such as ambient temperature and the functional failure criteria of the PSS. Dynamic reliability methodologies should be integrated in the PSS reliability analysis to have a true estimate of system failure probability. The methodology should estimate the physical variation of the parameters and the frequency of the accident sequences when the dynamic effects are considered

  9. Progress towards the specification of embodied energy performance criteria for New Zealand buildings

    Energy Technology Data Exchange (ETDEWEB)

    Baird, G.; Alcorn, A.; Wood, P.; Storey, J. B. [Victoria Univ., Wellington (New Zealand). School of Architecture; Jaques, R. [Building Research Association of New Zealand, Inc. (New Zealand)

    1998-11-01

    Incorporation of embodied energy performance criteria into New Zealand`s recently adopted performance-based building code is discussed. The paper also describes the concept of the Building Code and its energy related clauses and standards, work done to date to update the building materials` energy coefficients, and the progress made in using an embodied energy database. The purpose, desirability and likely pitfalls of such criteria, ways of specifying minimum performance, and relationships with operating energy criteria are also reviewed.

  10. MYRRHA cryogenic system study on performances and reliability requirements

    International Nuclear Information System (INIS)

    Junquera, T.; Chevalier, N.R.; Thermeau, J.P.; Medeiros Romao, L.; Vandeplassche, D.

    2015-01-01

    A precise evaluation of the cryogenic requirements for accelerator-driven system such as the MYRRHA project has been performed. In particular, operation temperature, thermal losses, and required cryogenic power have been evaluated. A preliminary architecture of the cryogenic system including all its major components, as well as the principles for the cryogenic fluids distribution has been proposed. A detailed study on the reliability aspects has also been initiated. This study is based on the reliability of large cryogenic systems used for accelerators like HERA, LHC or SNS Linac. The requirements to guarantee good cryogenic system availability can be summarised as follows: 1) Mean Time Between Maintenance (MTBM) should be > 8 000 hours; 2) Valves, heat exchangers and turbines are particularly sensitive elements to impurities (dust, oil, gases), improvements are necessary to keep a minimal level in these components; 3) Redundancy studies for all elements containing moving/vibrating parts (turbines, compressors, including their respective bearings and seal shafts) are necessary; 4) Periodic maintenance is mandatory: oil checks, control of screw compressors every 10.000-15.000 hours, vibration surveillance programme, etc; 5) Special control and maintenance of utilities equipment (supply of cooling water, compressed air and electrical supply) is necessary; 6) Periodic vacuum checks to identify leakage appearance such as insulation vacuum of transfer lines and distribution boxes are necessary; 7) Easily exchangeable cold compressors are required

  11. Radiation protection - Performance criteria for service laboratories performing biological dosimetry by cytogenetics

    International Nuclear Information System (INIS)

    2004-01-01

    This International Standard provides criteria for quality assurance and quality control, evaluation of the performance and the accreditation of biological dosimetry by cytogenetic service laboratories. This International Standard addresses: a) the confidentiality of personal information, for the customer and the service laboratory, b) the laboratory safety requirements, c) the calibration sources and calibration dose ranges useful for establishing the reference dose-effect curves allowing the dose estimation from chromosome aberration frequency, and the minimum detection levels, d) the scoring procedure for unstable chromosome aberrations used for biological dosimetry, e) the criteria for converting a measured aberration frequency into an estimate of absorbed dose, f) the reporting of results, g) the quality assurance and quality control, h) informative annexes containing examples of a questionnaire, instructions for customers, a data sheet for recording aberrations and a sample report

  12. The Japanese version of the modified ACR preliminary diagnostic criteria for fibromyalgia and the fibromyalgia symptom scale: reliability and validity.

    Science.gov (United States)

    Usui, Chie; Hatta, Kotaro; Aratani, Satoko; Yagishita, Naoko; Nishioka, Kenya; Kanazawa, Teruhisa; Itoh, Kenji; Yamano, Yoshihisa; Nakamura, Hiroyuki; Nakajima, Toshihiro; Nishioka, Kusuki

    2013-09-01

    The aim of this study is to investigate the reliability and validity of the Japanese version of the modified American College of Rheumatology (ACR) Preliminary Diagnostic Criteria for Fibromyalgia (mACR 2010-J) and the Fibromyalgia Symptom Scale (mFS-J). According to the ACR 1990 classification criteria, patients with chronic pain were divided into the fibromyalgia group and nonfibromyalgia group (rheumatoid arthritis and osteoarthritis). Patients in both groups were assessed using mACR 2010-J and mFS-J. 294 of 462 (64 %) patients in the fibromyalgia group met mACR 2010-J, whereas 4 % (9/231) of the nonfibromyalgia group did, with sensitivity of 64 %, specificity of 96 %, positive predictive value of 97 %, negative predictive value of 56 %, and positive likelihood ratio of 16.3. Mean total scores on mFS-J significantly differentiated the fibromyalgia from the nonfibromyalgia group. According to the value of the Youden index, the best cutoff score for the mFS-J was 9/10. Our findings indicate that mACR 2010-J as a positive test and mFS-J as a quantification scale might be suitable for assessing fibromyalgia among Japanese chronic pain populations.

  13. System principles and evaluation criteria of reliability for optimization of technological parameters of coal deposits

    Directory of Open Access Journals (Sweden)

    A.О. Khorolskiy

    2017-12-01

    Full Text Available The article deals with solving the scientific problem of select mining equipment for selection longwall faces of mining venture. The main goal of the paper is to study technology of coal extraction of mining venture. The paper proposes a new approach to solve a problem of mining equipment selection for longwall faces of mining venture. The article describes new method for selection of mining equipment based on theory graph. Special attention is given to technological aspects; they are lenght of longwall faces, depth of coal stratum. Predictions obtained for daily production of mining equipment are compared with design outputs. Conclusions regarding the main reason of instability of longwall faces workings are made. It is found that to be able to use standard algorithms find the shortest path between vertices, you must perform matrix description of the constructed graphs that illustrate the structure of the interaction of different types of control equipment. Using classical optimization of method of discrete mathematics and algorithms for finding the shortest path between two vertices of network models obtained from the formalization of graphs with maximum results of specific types of equipment production chains, solved the problem of rational choice cleaning equipment for the new site with the cost parameters of the mining equipment and cost of mining coal. The authors developed effective and appropriate variants for the mine development for different coal deposits of mining venture.

  14. Application of SAW method for multiple-criteria comparative analysis of the reliability of heat supply organizations

    Science.gov (United States)

    Akhmetova, I. G.; Chichirova, N. D.

    2016-12-01

    and the analysis of heat-supply organizations is performed by the example of the Republic of Tatarstan. The assessment system is based on construction of comparative ratings of heat-supply organizations. A rating is the assessment of reliability of the organization, is characterized by a numerical value, and makes it possible to compare organizations engaged in the same kind of activity between each other.

  15. 77 FR 19391 - Notice of Proposed Intelligent Mail Indicia Performance Criteria With Request for Comments

    Science.gov (United States)

    2012-03-30

    ... POSTAL SERVICE Notice of Proposed Intelligent Mail Indicia Performance Criteria With Request for... replacement of the current Information-Based Indicia Performance Criteria (IBI PC) with new Intelligent Mail... the Payment Technology office. FOR FURTHER INFORMATION CONTACT: Marlo Kay Ivey, Business Programs...

  16. DEVELOPING OF INDIVIDUAL INSTRUMENT PERFORMANCE ANXIETY SCALE: VALIDITY - RELIABILITY STUDY

    Directory of Open Access Journals (Sweden)

    Esra DALKIRAN

    2014-07-01

    Full Text Available The purpose of this study is to develop a scale unique to our culture, concerning  individual instrument performance anxiety of the students  who are getting instrument training  in the Department of Music Education. In the study, the descriptive research model is used and qualitative research techniques are utilized. The study population consists of the students attending the 23 universities which has Music Education Department. The sample of the study consists of 438 girls and 312 boys, totally 750 students  who are studying in the Department of Music Education of randomly selected 10 universities. As a result of the explanatory and confirmatory factor analyses that were performed, a one-dimensional structure consisting of 14 items was obtained. Also, t-scores and  the coefficient scores of total item correlation concerning the distinguishing power of the items, the difference in the scores of the set of lower and upper 27% was calculated, and it was observed that the items are distinguishing as a result of both analyses. Of the scale, Cronbach's alpha coefficient of internal consistency was calculated as .94, and test-retest reliability coefficient was calculated as .93. As a result, a valid and reliable assessment and evaluation instrument that measures the exam performance anxiety of the students studying in the Department of Music Education, has been developed.Extended AbstractsIntroductionAnxiety is a universal phenomenon which people experience once or a few times during lives. It was accepted as concern for the future or as an unpleasant emotional experience regarding probable hitches of the events (Di Tomasso & Gosch, 2002.In general, the occasions on which negative feelings are experienced cause anxiety to arise (Baltaş and Baltaş, 2000. People also feel anxious in dangerous situations. Anxiety may lead a person to be creative, while it may have hindering characteristics. Anxiety is that an individual considers him

  17. Are regulation-driven performance criteria still acceptable? - The German point of view.

    Science.gov (United States)

    Orth, Matthias

    2015-05-01

    Performance criteria should be a challenge for the laboratories to improve their quality. In countries with mandatory proficiency testing, the definition of performance criteria is a particular issue. If the definition of performance criteria is mandated from the regulatory bodies to medico-scientific institutions, scientific approaches (i.e., based on biological variation), the state-of-the-art approach (i.e., based on technical feasibility) as well as medical needs can be used to set up performance criteria such as the Richtlinie der Bundesärztekammer (RiliBÄK; Guideline of the German Medical Association on Quality Assurance in Medical Laboratory Examinations) in Germany. The experiences with RiliBÄK show that these performance criteria have to be revised on an ongoing basis.

  18. The impact of multi-criteria performance measurement on business performance improvement

    Directory of Open Access Journals (Sweden)

    Fentahun Moges Kasie

    2013-06-01

    Full Text Available Purpose: The purpose of this paper is to investigate the relationship between multi-criteria performance measurement (MCPM practice and business performance improvement using the raw data collected from 33 selected manufacturing companies. In addition, it proposes modified MCPM model as an effective approach to improve business performance of manufacturing companies. Design/methodology/approach:Research paper. Primary and secondary data were collected using questionnaire survey, interview and observation of records. The methodology is to evaluate business performances of sampled manufacturing companies and the extent of utilization of crucial non-financial (lagging and non-financial (leading performance measures. The positive correlation between financial business performance and practice of MCPM is clearly shown using Pearson’s correlation coefficient analysis. Findings –This research paper indicates that companies which measure their performance using important financial and non-financial measures achieve better business performance. Even though certain companies are currently using non-financial measures, the researchers have learned that these financial measures were not integrated with each other, financial measures and strategic objectives. Research limitations/implications: The limitation of this paper is that the number of surveyed companies is small to make generalization and they are found in a single country. Further researches which incorporate a large number of companies from various developing nations are suggested to minimize the limitation of this research.Practical Implication: The paper shows that multi-dimensional performance measures with the inclusion of key leading indicator are essential to predict the future environment. But cost-accounting based financial measures are inadequate to do so. These are shown practically using Pearson’s correlation coefficient analysis. Originality/value: The significance of multi

  19. Testing Standard Reliability Criteria

    Science.gov (United States)

    Sherry, David

    2017-01-01

    Maul's paper, "Rethinking Traditional Methods of Survey Validation" (Andrew Maul), contains two stages. First he presents empirical results that cast doubt on traditional methods for validating psychological measurement instruments. These results motivate the second stage, a critique of current conceptions of psychological measurement…

  20. Establishing Pass/Fail Criteria for Bronchoscopy Performance

    DEFF Research Database (Denmark)

    Konge, Lars; Clementsen, Paul; Larsen, Klaus Richter

    2012-01-01

    Background: Several tools have been created to assess competence in bronchoscopy. However, educational guidelines still use an arbitrary number of performed procedures to decide when basic competency is acquired. Objectives: The purpose of this study was to define pass/fail scores for two...... method. In the first we compared bronchoscopy performance scores of 14 novices with the scores of 14 experienced consultants to find the score that best discriminated between the two groups. In the second we asked an expert group of 7 experienced bronchoscopists to judge how a borderline trainee would...

  1. Performance Based Criteria for Ship Collision and Grounding

    DEFF Research Database (Denmark)

    Pedersen, Preben Terndrup

    2009-01-01

    The paper outlines a probabilistic procedure whereby the maritime industry can develop performance based rules to reduce the risk associated with human, environmental and economic costs of collision and grounding events and identify the most economic risk control options associated with prevention...

  2. An Empirical Investigation of MPA Student Performance and Admissions Criteria

    Science.gov (United States)

    Ragothaman, Srinivasan; Carpenter, Jon; Davies, Thomas

    2009-01-01

    The quality of a Master of Professional Accountancy (MPA) program, similar to other undergraduate and graduate programs in business and other disciplines, is typically directly related to the quality of its students. While there is a considerable published scholarly work on MBA student performance, there is very little research to predict student…

  3. Sources and performance criteria of uncertainty of reference measurement procedures.

    Science.gov (United States)

    Mosca, Andrea; Paleari, Renata

    2018-05-29

    This article wants to focus on the today available Reference Measurement Procedures (RMPs) for the determination of various analytes in Laboratory Medicine and the possible tools to evaluate their performance in the laboratories who are currently using them. A brief review on the RMPs has been performed by investigating the Joint Committee for Traceability in Laboratory Medicine (JCTLM) database. In order to evaluate their performances, we have checked the organization of three international ring trials, i.e. those regularly performed by the IFCC External Quality assessment scheme for Reference Laboratories in Laboratory Medicine (RELA), by the Center for Disease Control and Prevention (CDC) cholesterol network and by the IFCC Network for HbA 1c . Several RMPs are available through the JCTLM database, but the best way to collect information about the RMPs and their uncertainties is to look at the reference measurement service providers (RMS). This part of the database and the background on how to listed in the database is very helpful for the assessment of expanded uncertainty (MU) and performance in general of RMPs. Worldwide, 17 RMS are listed in the database, and for most of the measurands more than one RMS is able to run the relative RMPs, with similar expanded uncertainties. As an example, for a-amylase, 4 SP offer their services with MU between 1.6 and 3.3%. In other cases (such as total cholesterol, the U may span over a broader range, i.e. from 0.02 to 3.6%). With regard to the performance evaluation, the approach is often heterogenous, and it is difficult to compare the performance of laboratories running the same RMP for the same measurand if involved in more than one EQAS. The reference measurement services have been created to help laboratory professionals and manufacturers to implement the correct metrological traceability, and the JCTLM database is the only correct way to retrieve all the necessary important information to this end. Copyright © 2018

  4. Development of a valid and reliable test to assess trauma radiograph interpretation performance

    International Nuclear Information System (INIS)

    Neep, M.J.; Steffens, T.; Riley, V.; Eastgate, P.; McPhail, S.M.

    2017-01-01

    new and novel scoring criteria. • Results from this study provide foundational evidence to support the reliability and validity of the IIT. • IIT can be used to assess image interpretation performance of adult trauma radiographs.

  5. Determining Criteria to Predict Repeatability of Performance in Older Adults: Using Coefficients of Variation for Strength and Functional Measures.

    Science.gov (United States)

    Raj, Isaac Selva; Bird, Stephen R; Westfold, Ben A; Shield, Anthony J

    2017-01-01

    Reliable measures of muscle strength and functional capacity in older adults are essential. The aim of this study was to determine whether coefficients of variation (CVs) of individuals obtained at the first session can infer repeatability of performance in a subsequent session. Forty-eight healthy older adults (mean age 68.6 ± 6.1 years; age range 60-80 years) completed two assessment sessions, and on each occasion undertook: dynamometry for isometric and isokinetic quadriceps strength, 6 meter fast walk (6MFWT), timed up and go (TUG), stair climb and descent, and vertical jump. Significant linear relationships were observed between CVs in session 1 and the percentage difference between sessions 1 and 2 for torque at 60, 120, 240 and 360°/s, 6MFWT, TUG, stair climb, and stair descent. The results of this study could be used to establish criteria for determining an acceptably reliable performance in strength and functional tests.

  6. 40 CFR 262.104 - What are the minimum performance criteria?

    Science.gov (United States)

    2010-07-01

    ... words “laboratory waste” or with the chemical name of the contents. If the container is too small to...) SOLID WASTES (CONTINUED) STANDARDS APPLICABLE TO GENERATORS OF HAZARDOUS WASTE University Laboratories... criteria? The Minimum Performance Criteria that each University must meet in managing its Laboratory Waste...

  7. Performance criteria for solidified high-level radioactive wastes. Environmental impact statement. Revision 1

    International Nuclear Information System (INIS)

    1977-09-01

    This draft Environmental Impact Statement on performance criteria for solidified high-level radioactive wastes (PCSHLW) covers: considerations for PCSHLW development, the proposed rulemaking, characteristics of the PCSHLW, environmental impacts of the proposed PCSHLW, alternatives to the PCSHLW criteria, and cost/benefit/risk evaluation. Five appendices are included to support the technical data required in the Environmental Impact Statement

  8. Research on performance-based seismic design criteria

    Institute of Scientific and Technical Information of China (English)

    谢礼立; 马玉宏

    2002-01-01

    The seismic design criterion adopted in the existing seismic design codes is reviewed. It is pointed out that the presently used seismic design criterion is not satisfied with the requirements of nowadays social and economic development. A new performance-based seismic design criterion that is composed of three components is presented in this paper. It can not only effectively control the economic losses and casualty, but also ensure the building(s function in proper operation during earthquakes. The three components are: classification of seismic design for buildings, determination of seismic design intensity and/or seismic design ground motion for controlling seismic economic losses and casualties, and determination of the importance factors in terms of service periods of buildings. For controlling the seismic human losses, the idea of socially acceptable casualty level is presented and the (Optimal Economic Decision Model( and (Optimal Safe Decision Model( are established. Finally, a new method is recommended for calculating the importance factors of structures by adjusting structures service period on the base of more important structure with longer service period than the conventional ones. Therefore, the more important structure with longer service periods will be designed for higher seismic loads, in case the exceedance probability of seismic hazard in different service period is same.

  9. Strong stabilization servo controller with optimization of performance criteria.

    Science.gov (United States)

    Sarjaš, Andrej; Svečko, Rajko; Chowdhury, Amor

    2011-07-01

    Synthesis of a simple robust controller with a pole placement technique and a H(∞) metrics is the method used for control of a servo mechanism with BLDC and BDC electric motors. The method includes solving a polynomial equation on the basis of the chosen characteristic polynomial using the Manabe standard polynomial form and parametric solutions. Parametric solutions are introduced directly into the structure of the servo controller. On the basis of the chosen parametric solutions the robustness of a closed-loop system is assessed through uncertainty models and assessment of the norm ‖•‖(∞). The design procedure and the optimization are performed with a genetic algorithm differential evolution - DE. The DE optimization method determines a suboptimal solution throughout the optimization on the basis of a spectrally square polynomial and Šiljak's absolute stability test. The stability of the designed controller during the optimization is being checked with Lipatov's stability condition. Both utilized approaches: Šiljak's test and Lipatov's condition, check the robustness and stability characteristics on the basis of the polynomial's coefficients, and are very convenient for automated design of closed-loop control and for application in optimization algorithms such as DE. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Understanding organic photovoltaic cells: Electrode, nanostructure, reliability, and performance

    Science.gov (United States)

    Kim, Myung-Su

    My Ph.D. research has focused on alternative renewable energy using organic semiconductors. During my study, first, I have established reliable characterization methods of organic photovoltaic devices. More specifically, less than 5% variation of power conversion efficiency of fabricated organic blend photovoltaic cells (OBPC) was achieved after optimization. The reproducibility of organic photovoltaic cell performance is one of the essential issues that must be clarified before beginning serious investigations of the application of creative and challenging ideas. Second, the relationships between fill factor (FF) and process variables have been demonstrated with series and shunt resistance, and this provided a chance to understand the electrical device behavior. In the blend layer, series resistance (Rs) and shunt resistance (Rsh) were varied by controlling the morphology of the blend layer, the regioregularity of the conjugated polymer, and the thickness of the blend layer. At the interface between the cathode including PEDOT:PSS and the blend layer, cathode conductivity was controlled by varying the structure of the cathode or adding an additive. Third, we thoroughly examined possible characterization mistakes in OPVC. One significant characterization mistake is observed when the crossbar electrode geometry of OPVC using PEDOT:PSS was fabricated and characterized with illumination which is larger than the actual device area. The hypothesis to explain this overestimation was excess photo-current generated from the cell region outside the overlapped electrode area, where PEDOT:PSS plays as anode and this was clearly supported with investigations. Finally, I incorporated a creative idea, which enhances the exciton dissociation efficiency by increasing the interface area between donor and acceptor to improve the power conversion efficiency of organic photovoltaic cells. To achieve this, nanoimprint lithography was applied for interface area increase. To clarify the

  11. 23 CFR 636.205 - Can past performance be used as an evaluation criteria?

    Science.gov (United States)

    2010-04-01

    ... indicator of an offeror's ability to perform the contract successfully. Past performance information may be... performance information regarding predecessor companies, key personnel who have relevant experience, or... 23 Highways 1 2010-04-01 2010-04-01 false Can past performance be used as an evaluation criteria...

  12. Reliable and valid assessment of performance in thoracoscopy

    DEFF Research Database (Denmark)

    Konge, Lars; Lehnert, Per; Hansen, Henrik Jessen

    2012-01-01

    BACKGROUND: As we move toward competency-based education in medicine, we have lagged in developing competency-based evaluation methods. In the era of minimally invasive surgery, there is a need for a reliable and valid tool dedicated to measure competence in video-assisted thoracoscopic surgery....... The purpose of this study is to create such an assessment tool, and to explore its reliability and validity. METHODS: An expert group of physicians created an assessment tool consisting of 10 items rated on a five-point rating scale. The following factors were included: economy and confidence of movement...

  13. Admissions Criteria and Academic Performance in the AFIT Graduate Cost Analysis Program

    National Research Council Canada - National Science Library

    Garwood, Kenneth

    2002-01-01

    .... Using the cumulative graduate grade point average earned at AFIT as the measure of academic performance, comparisons were made between the predictive capability of the current criteria and other potential factors...

  14. Final waste forms project: Performance criteria for phase I treatability studies

    International Nuclear Information System (INIS)

    Gilliam, T.M.; Hutchins, D.A.; Chodak, P. III

    1994-06-01

    This document defines the product performance criteria to be used in Phase I of the Final Waste Forms Project. In Phase I, treatability studies will be performed to provide open-quotes proof-of-principleclose quotes data to establish the viability of stabilization/solidification (S/S) technologies. This information is required by March 1995. In Phase II, further treatability studies, some at the pilot scale, will be performed to provide sufficient data to allow treatment alternatives identified in Phase I to be more fully developed and evaluated, as well as to reduce performance uncertainties for those methods chosen to treat a specific waste. Three main factors influence the development and selection of an optimum waste form formulation and hence affect selection of performance criteria. These factors are regulatory, process-specific, and site-specific waste form standards or requirements. Clearly, the optimum waste form formulation will require consideration of performance criteria constraints from each of the three categories. Phase I will focus only on the regulatory criteria. These criteria may be considered the minimum criteria for an acceptable waste form. In other words, a S/S technology is considered viable only if it meet applicable regulatory criteria. The criteria to be utilized in the Phase I treatability studies were primarily taken from Environmental Protection Agency regulations addressed in 40 CFR 260 through 265 and 268; and Nuclear Regulatory Commission regulations addressed in 10 CFR 61. Thus the majority of the identified criteria are independent of waste form matrix composition (i.e., applicable to cement, glass, organic binders etc.)

  15. Final waste forms project: Performance criteria for phase I treatability studies

    Energy Technology Data Exchange (ETDEWEB)

    Gilliam, T.M. [Oak Ridge National Lab., TN (United States); Hutchins, D.A. [Martin Marietta Energy Systems, Inc., Oak Ridge, TN (United States); Chodak, P. III [Massachusetts Institute of Technology (United States)

    1994-06-01

    This document defines the product performance criteria to be used in Phase I of the Final Waste Forms Project. In Phase I, treatability studies will be performed to provide {open_quotes}proof-of-principle{close_quotes} data to establish the viability of stabilization/solidification (S/S) technologies. This information is required by March 1995. In Phase II, further treatability studies, some at the pilot scale, will be performed to provide sufficient data to allow treatment alternatives identified in Phase I to be more fully developed and evaluated, as well as to reduce performance uncertainties for those methods chosen to treat a specific waste. Three main factors influence the development and selection of an optimum waste form formulation and hence affect selection of performance criteria. These factors are regulatory, process-specific, and site-specific waste form standards or requirements. Clearly, the optimum waste form formulation will require consideration of performance criteria constraints from each of the three categories. Phase I will focus only on the regulatory criteria. These criteria may be considered the minimum criteria for an acceptable waste form. In other words, a S/S technology is considered viable only if it meet applicable regulatory criteria. The criteria to be utilized in the Phase I treatability studies were primarily taken from Environmental Protection Agency regulations addressed in 40 CFR 260 through 265 and 268; and Nuclear Regulatory Commission regulations addressed in 10 CFR 61. Thus the majority of the identified criteria are independent of waste form matrix composition (i.e., applicable to cement, glass, organic binders etc.).

  16. Maintenance personnel performance simulation (MAPPS): a model for predicting maintenance performance reliability in nuclear power plants

    International Nuclear Information System (INIS)

    Knee, H.E.; Krois, P.A.; Haas, P.M.; Siegel, A.I.; Ryan, T.G.

    1983-01-01

    The NRC has developed a structured, quantitative, predictive methodology in the form of a computerized simulation model for assessing maintainer task performance. Objective of the overall program is to develop, validate, and disseminate a practical, useful, and acceptable methodology for the quantitative assessment of NPP maintenance personnel reliability. The program was organized into four phases: (1) scoping study, (2) model development, (3) model evaluation, and (4) model dissemination. The program is currently nearing completion of Phase 2 - Model Development

  17. Technical evaluation of draft ANSI Standard N13.30, ''performance criteria for radiobioassay''

    International Nuclear Information System (INIS)

    MacLellan, J.A.; Traub, R.J.

    1986-03-01

    The Pacific Northwest Laboratory (PNL) is conducting a research program to evaluate the appropriateness of criteria in the ANSI draft Standard N13.30, ''Performance Criteria for Radiobioassay.'' The evaluation has progressed parallel with the preparation of the Standard by evaluating the performance of existing bioassay laboratories against the criteria specified. Recommendations for revision of the Standard and implementation of a testing/accreditation program have been formulated based on study results. The current performance testing program includes both in-vivo counting and in-vitro sample measurements. Test criteria specified in the Standard include relative bias, relative precision, and acceptable minimum detectable activity (AMDA). Results to date have indicated that the acceptance criteria in the Standard are appropriate for the existing state of the industry and are achievable by a majority of the participating laboratories. Specific conclusions are that the AMDA criteria are most difficult for the laboratories to achieve; the relative bias criterion is second in difficulty, and the precision criterion presents no problem for the laboratories; most of the participating laboratories can meet the Standard; and failure rates may decrease as the laboratories become more knowledgeable of the performance criteria. 3 refs., 11 figs., 6 tabs

  18. Reliability of magnetic particle inspection performed through coatings: Final report

    International Nuclear Information System (INIS)

    1988-07-01

    The magnetic particle examination (MT) technique can reliably examine containment welds without removing their protective coatings. This study has investigated a variety of MT methods used in the oil and gas industry for their suitability for nuclear plant applications. 102 figs

  19. Applications of Human Performance Reliability Evaluation Concepts and Demonstration Guidelines

    Science.gov (United States)

    1977-03-15

    ship stops dead in the water and the AN/SQS-26 operator recommends a new heading (000°). At T + 14 minutes, the target ship begins a hard turn to...Various Simulated Conditions 82 9 Hunan Reliability for Each Simulated Operator (Baseline Run) 83 10 Human and Equipment Availabilit / under

  20. Reliability of EP3OS symptom criteria and nasal endoscopy in the assessment of chronic rhinosinusitis - a GA(2) LEN study

    DEFF Research Database (Denmark)

    Tomassen, P; Newson, R B; Hoffmans, R

    2011-01-01

    To cite this article: Tomassen P, Newson RB, Hoffmans R, Lötvall J, Cardell LO, Gunnbjörnsdóttir M, Thilsing T, Matricardi P, Krämer U, Makowska JS, Brozek G, Gjomarkaj M, Howarth P, Loureiro C, Toskala E, Fokkens W, Bachert C, Burney P, Jarvis D. Reliability of EP3OS symptom criteria and nasal...

  1. Computed tomographic angiography criteria in the diagnosis of brain death - comparison of sensitivity and interobserver reliability of different evaluation scales

    International Nuclear Information System (INIS)

    Sawicki, Marcin; Walecka, A.; Bohatyrewicz, R.; Solek-Pastuszka, J.; Safranow, K.; Walecki, J.; Rowinski, O.; Czajkowski, Z.; Guzinski, M.; Burzynska, M.; Wojczal, J.

    2014-01-01

    The standardized diagnostic criteria for computed tomographic angiography (CTA) in diagnosis of brain death (BD) are not yet established. The aim of the study was to compare the sensitivity and interobserver agreement of the three previously used scales of CTA for the diagnosis of BD. Eighty-two clinically brain-dead patients underwent CTA with a delay of 40 s after contrast injection. Catheter angiography was used as the reference standard. CTA results were assessed by two radiologists, and the diagnosis of BD was established according to 10-, 7-, and 4-point scales. Catheter angiography confirmed the diagnosis of BD in all cases. Opacification of certain cerebral vessels as indicator of BD was highly sensitive: cortical segments of the middle cerebral artery (96.3 %), the internal cerebral vein (98.8 %), and the great cerebral vein (98.8 %). Other vessels were less sensitive: the pericallosal artery (74.4 %), cortical segments of the posterior cerebral artery (79.3 %), and the basilar artery (82.9 %). The sensitivities of the 10-, 7-, and 4-point scales were 67.1, 74.4, and 96.3 %, respectively (p < 0.001). Percentage interobserver agreement in diagnosis of BD reached 93 % for the 10-point scale, 89 % for the 7-point scale, and 95 % for the 4-point scale (p = 0.37). In the application of CTA to the diagnosis of BD, reducing the assessment of vascular opacification scale from a 10- to a 4-point scale significantly increases the sensitivity and maintains high interobserver reliability. (orig.)

  2. Computed tomographic angiography criteria in the diagnosis of brain death - comparison of sensitivity and interobserver reliability of different evaluation scales

    Energy Technology Data Exchange (ETDEWEB)

    Sawicki, Marcin; Walecka, A. [Pomeranian Medical University, Department of Diagnostic Imaging and Interventional Radiology, Szczecin (Poland); Bohatyrewicz, R.; Solek-Pastuszka, J. [Pomeranian Medical University, Clinic of Anesthesiology and Intensive Care, Szczecin (Poland); Safranow, K. [Pomeranian Medical University, Department of Biochemistry and Medical Chemistry, Szczecin (Poland); Walecki, J. [The Centre of Postgraduate Medical Education, Warsaw (Poland); Rowinski, O. [Medical University of Warsaw, 2nd Department of Clinical Radiology, Warsaw (Poland); Czajkowski, Z. [Regional Joint Hospital, Szczecin (Poland); Guzinski, M. [Wroclaw Medical University, Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw (Poland); Burzynska, M. [Wroclaw Medical University, Department of Anesthesiology and Intensive Therapy, Wroclaw (Poland); Wojczal, J. [Medical University of Lublin, Department of Neurology, Lublin (Poland)

    2014-08-15

    The standardized diagnostic criteria for computed tomographic angiography (CTA) in diagnosis of brain death (BD) are not yet established. The aim of the study was to compare the sensitivity and interobserver agreement of the three previously used scales of CTA for the diagnosis of BD. Eighty-two clinically brain-dead patients underwent CTA with a delay of 40 s after contrast injection. Catheter angiography was used as the reference standard. CTA results were assessed by two radiologists, and the diagnosis of BD was established according to 10-, 7-, and 4-point scales. Catheter angiography confirmed the diagnosis of BD in all cases. Opacification of certain cerebral vessels as indicator of BD was highly sensitive: cortical segments of the middle cerebral artery (96.3 %), the internal cerebral vein (98.8 %), and the great cerebral vein (98.8 %). Other vessels were less sensitive: the pericallosal artery (74.4 %), cortical segments of the posterior cerebral artery (79.3 %), and the basilar artery (82.9 %). The sensitivities of the 10-, 7-, and 4-point scales were 67.1, 74.4, and 96.3 %, respectively (p < 0.001). Percentage interobserver agreement in diagnosis of BD reached 93 % for the 10-point scale, 89 % for the 7-point scale, and 95 % for the 4-point scale (p = 0.37). In the application of CTA to the diagnosis of BD, reducing the assessment of vascular opacification scale from a 10- to a 4-point scale significantly increases the sensitivity and maintains high interobserver reliability. (orig.)

  3. Comparison between disign criteria and observed structural performance of underground openings at WIPP

    International Nuclear Information System (INIS)

    Cook, R.F.; Francke, C.

    1989-01-01

    This paper discusses the observed structural performance of the underground excavations at the Waste Isolation Pilot Plant (WIPP) in relation to design criteria. The criteria were established at an early stage of the project to define the functional and structural requirements that were to be addressed in the design of the facility. For the underground structural response, the criteria defined the requirements for the shaft and shaft liner design, mine design, waste emplacement, retrievability and instrumentation. The observed structural performance of the underground is determined by the field data that have been collected since excavations were started at the WIPP site. The observations include field measurements of rock and water conditions, as well as maintenance records. The data provide input to design confirmation, performance assessment and form the basis for the design of new underground structures. For this paper, the field data have been compared with the design criteria applicable to ground control to demonstrate that the requirements of the design are met

  4. Evaluation of Flagging Criteria of United States Kidney Transplant Center Performance: How to Best Define Outliers?

    Science.gov (United States)

    Schold, Jesse D; Miller, Charles M; Henry, Mitchell L; Buccini, Laura D; Flechner, Stuart M; Goldfarb, David A; Poggio, Emilio D; Andreoni, Kenneth A

    2017-06-01

    Scientific Registry of Transplant Recipients report cards of US organ transplant center performance are publicly available and used for quality oversight. Low center performance (LP) evaluations are associated with changes in practice including reduced transplant rates and increased waitlist removals. In 2014, Scientific Registry of Transplant Recipients implemented new Bayesian methodology to evaluate performance which was not adopted by Center for Medicare and Medicaid Services (CMS). In May 2016, CMS altered their performance criteria, reducing the likelihood of LP evaluations. Our aims were to evaluate incidence, survival rates, and volume of LP centers with Bayesian, historical (old-CMS) and new-CMS criteria using 6 consecutive program-specific reports (PSR), January 2013 to July 2015 among adult kidney transplant centers. Bayesian, old-CMS and new-CMS criteria identified 13.4%, 8.3%, and 6.1% LP PSRs, respectively. Over the 3-year period, 31.9% (Bayesian), 23.4% (old-CMS), and 19.8% (new-CMS) of centers had 1 or more LP evaluation. For small centers (evaluations (52 vs 13 PSRs) for 1-year mortality with Bayesian versus new-CMS criteria. For large centers (>183 transplants/PSR), there were 3-fold additional LP evaluations for 1-year mortality with Bayesian versus new-CMS criteria with median differences in observed and expected patient survival of -1.6% and -2.2%, respectively. A significant proportion of kidney transplant centers are identified as low performing with relatively small survival differences compared with expected. Bayesian criteria have significantly higher flagging rates and new-CMS criteria modestly reduce flagging. Critical appraisal of performance criteria is needed to assess whether quality oversight is meeting intended goals and whether further modifications could reduce risk aversion, more efficiently allocate resources, and increase transplant opportunities.

  5. Improving Stochastic Communication Network Performance: Reliability vs. Throughput

    Science.gov (United States)

    1991-12-01

    increased to one. 2) arc survivabil.. ities will be increased in increments of one tenths. and 3) the costs to increase- arc si’rvivabilities were equal and...This reliability value is leni used to maximize the associated expected flow. For Net work A. a bIdget of (8)() pro(duces a tradcoff point at (.58.37...Network B for a buidgel of 2000 which allows a nel \\\\ork relial)ilitv of one to be achieved and a bidget of 1200 which allows for ;, maximum 57

  6. Human Performance Modeling for Dynamic Human Reliability Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Boring, Ronald Laurids [Idaho National Laboratory; Joe, Jeffrey Clark [Idaho National Laboratory; Mandelli, Diego [Idaho National Laboratory

    2015-08-01

    Part of the U.S. Department of Energy’s (DOE’s) Light Water Reac- tor Sustainability (LWRS) Program, the Risk-Informed Safety Margin Charac- terization (RISMC) Pathway develops approaches to estimating and managing safety margins. RISMC simulations pair deterministic plant physics models with probabilistic risk models. As human interactions are an essential element of plant risk, it is necessary to integrate human actions into the RISMC risk framework. In this paper, we review simulation based and non simulation based human reliability analysis (HRA) methods. This paper summarizes the founda- tional information needed to develop a feasible approach to modeling human in- teractions in RISMC simulations.

  7. A study on the establishment of component/equipment performance criteria considering Heavy Water Reactor characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Keun Sun; Kwon, Young Chul; Lee, Min Kyu; Lee, Yun Soo [Sunmoon Univ., Asan (Korea, Republic of); Chang, Seong Hoong; Ryo, Chang Hyun [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Kim, Soong Pyung; Hwnag, Jung Rye; Chung, Chul Kee [Chosun Univ., Gwangju (Korea, Republic of)

    2002-03-15

    Foreign and domestic technology trends, regulatory requirements, design and researches for heavy water reactors are analyzed. Safety design guides of Canada industry and regulatory documents and consultative documents of Canada regulatory agency are reviewed. Applicability of MOST guidance 16 Revision 'guidance for technical criteria of nuclear reactor facility' is reviewed. Specific performance criteria are established for components and facilities for heavy water reactor.

  8. Determination of performance criteria of safety systems in a nuclear power plant via simulated annealing optimization method

    International Nuclear Information System (INIS)

    Jung, Woo Sik

    1993-02-01

    This study presents and efficient methodology that derives design alternatives and performance criteria of safety functions/systems in commercial nuclear power plants. Determination of design alternatives and intermediate-level performance criteria is posed as a reliability allocation problem. The reliability allocation is performed for determination of reliabilities of safety functions/systems from top-level performance criteria. The reliability allocation is a very difficult multi objective optimization problem (MOP) as well as a global optimization problem with many local minima. The weighted Chebyshev norm (WCN) approach in combination with an improved Metropolis algorithm of simulated annealing is developed and applied to the reliability allocation problem. The hierarchy of probabilistic safety criteria (PSC) may consist of three levels, which ranges from the overall top level (e.g., core damage frequency, acute fatality and latent cancer fatality) through the interlnediate level (e.g., unavailiability of safety system/function) to the low level (e.g., unavailability of components, component specifications or human error). In order to determine design alternatives of safety functions/systems and the intermediate-level PSC, the reliability allocation is performed from the top-level PSC. The intermediated level corresponds to an objective space and the top level is related to a risk space. The reliability allocation is performed by means of a concept of two-tier noninferior solutions in the objective and risk spaces within the top-level PSC. In this study, two kinds of towtier noninferior solutions are defined: intolerable intermediate-level PSC and desirable design alternatives of safety functions/systems that are determined from Sets 1 and 2, respectively. Set 1 is obtained by maximizing simultaneously not only safety function/system unavailabilities but also risks. Set 1 reflects safety function/system unavailabilities in the worst case. Hence, the

  9. Lean Information Management: Criteria For Selecting Key Performance Indicators At Shop Floor

    Science.gov (United States)

    Iuga, Maria Virginia; Kifor, Claudiu Vasile; Rosca, Liviu-Ion

    2015-07-01

    Most successful organizations worldwide use key performance indicators as an important part of their corporate strategy in order to forecast, measure and plan their businesses. Performance metrics vary in their purpose, definition and content. Therefore, the way organizations select what they think are the optimal indicators for their businesses varies from company to company, sometimes even from department to department. This study aims to answer the question of what is the most suitable way to define and select key performance indicators. More than that, it identifies the right criteria to select key performance indicators at shop floor level. This paper contributes to prior research by analysing and comparing previously researched selection criteria and proposes an original six-criteria-model, which caters towards choosing the most adequate KPIs. Furthermore, the authors take the research a step further by further steps to closed research gaps within this field of study.

  10. Validity and reliability problems with patient global as a component of the ACR/EULAR remission criteria as used in clinical practice.

    Science.gov (United States)

    Masri, Karim R; Shaver, Timothy S; Shahouri, Shadi H; Wang, Shirley; Anderson, James D; Busch, Ruth E; Michaud, Kaleb; Mikuls, Ted R; Caplan, Liron; Wolfe, Frederick

    2012-06-01

    To investigate what factors influence patient global health assessment (PtGlobal), and how those factors and the reliability of PtGlobal affect the rate, reliability, and validity of recently published American College of Rheumatology/European League Against Rheumatism (ACR/EULAR) rheumatoid arthritis (RA) remission criteria when used in clinical practice. We examined consecutive patients with RA in clinical practice and identified 77 who met ACR/EULAR joint criteria for remission (≤ 1 swollen joint and ≤ 1 tender joint). We evaluated factors associated with a PtGlobal > 1, because a PtGlobal ≤ 1 defined ACR/EULAR remission in this group of patients who had already met ACR/EULAR joint criteria. Of the 77 patients examined, only 17 (22.1%) had PtGlobal ≤ 1 and thus fully satisfied ACR/EULAR criteria. A large proportion of patients not in remission by ACR/EULAR criteria had high PtGlobal related to noninflammatory issues, including low back pain, fatigue, and functional limitations, and a number of patients clustered in the range of PtGlobal > 1 and ≤ 2. However, the minimal detectable difference for PtGlobal was 2.3. In addition, compared with a PtGlobal severity score, a PtGlobal activity score was 3.3% less likely to be abnormal (> 1). Noninflammatory factors contribute to the level of PtGlobal and result in the exclusion of many patients who would otherwise be in "true" remission according to the ACR/EULAR definition. Reliability problems associated with PtGlobal can also result in misclassification, and may explain the observation of low longterm remission rates in RA. As currently constituted, the use of the ACR/EULAR remission criteria in clinical practice appears to be problematic.

  11. Multi-criteria decision making under uncertainty in building performance assessment

    NARCIS (Netherlands)

    Hopfe, C.J.; Augenbroe, G.; Hensen, J.L.M.

    2013-01-01

    Building performance assessment is complex, as it has to respond to multiple criteria. Objectives originating from the demands that are put on energy consumption, acoustical performance, thermal occupant comfort, indoor air quality and many other issues must all be reconciled. An assessment requires

  12. The role of human reliability analysis for enhancing crew performance

    International Nuclear Information System (INIS)

    Hannaman, G.W.; Joksimovich, V.; Worledge, D.H.; Spurgin, A.J.

    1986-01-01

    This paper summarizes some aspects of EPRI-sponsored research undertaken in support of improving the PRA technology. In particular, the consideration of how human actions that impact accident sequences can be analyzed in a systematic way to supplement the type of ergonomic studies normally carried out in support of control room design. The HRA/PRA approach described not only identifies the operator information and interface needs, but also helps to identify issues and areas for additional research. The process includes a link to data collections. Preliminary collections of data and analytical benchmark support the idea that such analytical frameworks and models provide support for ranking the importance of various human reliability issues

  13. Carbohydrate ingestion improves performance of a new reliable test of soccer performance.

    Science.gov (United States)

    Currell, Kevin; Conway, Steve; Jeukendrup, Asker E

    2009-02-01

    The aim of the study was to investigate the reliability of a new test of soccer performance and evaluate the effect of carbohydrate (CHO) on soccer performance. Eleven university footballers were recruited and underwent 3 trials in a randomized order. Two of the trials involved ingesting a placebo beverage, and the other, a 7.5% maltodextrin solution. The protocol comprised a series of ten 6-min exercise blocks on an outdoor Astroturf pitch, separated by the performance of 2 of the 4 soccer-specific tests, making the protocol 90 min in duration. The intensity of the exercise was designed to be similar to the typical activity pattern during soccer match play. Participants performed skill tests of dribbling, agility, heading, and shooting throughout the protocol. The coefficients of variation for dribbling, agility, heading, and shooting were 2.2%, 1.2%, 7.0%, and 2.8%, respectively. The mean combined placebo scores were 42.4 +/- 2.7 s, 43.1 +/- 3.7 s, 210 +/- 34 cm, and 212 +/- 17 points for agility, dribbling, heading, and kicking, respectively. CHO ingestion led to a combined agility time of 41.5 +/- 0.8 s, for dribbling 41.7 +/- 3.5 s, 213 +/- 11 cm for heading, and 220 +/- 5 points for kicking accuracy. There was a significant improvement in performance for dribbling, agility, and shooting (p soccer performance, and ingesting CHO leads to an improvement in soccer performance.

  14. Technical evaluation of draft ANSI Standard N13.30, ''Performance Criteria for Radiobioassay''

    International Nuclear Information System (INIS)

    MacLellan, J.A.; Traub, R.J.

    1986-01-01

    To evaluate the appropriateness of the draft Standard, a research program, entitled Technical Evaluation of Draft ANSI Standard N13.30, ''Performance Criteria for Radiobioassay,'' was initiated at the Pacific Northwest Laboratory (PNL). This program incorporates a number of tasks including a nationwide, two-round intercomparison study to test the analytical performance of both in-vitro and in-vivo bioassay laboratories and determine their ability to meet the minimum performance criteria specified in the American National Standards Institute (ANSI) draft Standard, and other tasks related to the establishment of an accreditation laboratory. Based on two rounds of in-vitro testing and the in-vivo pilot study, the project staff has concluded that the criteria selected are appropriate for the existing state of the industry and achievable by most participating laboratories. Specific conclusions are as follows: the AMDA criteria are most difficult for the laboratories to achieve, the relative bias criterion is second in difficulty, and the precision criterion presents no problem for the laboratories, most of the participating laboratories can meet the Standard, and failure rates may decrease as the laboratories become knowledgeable of the performance criteria

  15. Human performance and reliability studies on nuclear power plant

    International Nuclear Information System (INIS)

    Miyaoka, S.

    1988-01-01

    The TMI accident in USA, the Chernobyl accident in USSR and other major accidents overseas have shown that it is necessary to investigate and research human factor problems related to operation, maintenance and others in order to increase the safety and reliability of nuclear power plants. Although a variety of countermeasures have been devised, the accidents and failures due to human factors still occur. So far, the problems related to human factors have not been fundamantally and systematically investigated. Also the data base related to this problem has not been developed. Therefore, the government and electric utility industry began the research on the prevention of the accidents caused by human errors. The basic research is carried out by the government, and the applied research is done by electric utility industry. The Central Research Institute of Electric Power Industry established the Human Factors Research Center on July 1, 1987. The research program in the Human Factors Research Center is divided into the basic research to clarity fundamental human characteristics, the systematic research to apply this information and the analytical research on human error experience. These research activities are reported. (Kako, I.)

  16. Reliability-based econometrics of aerospace structural systems: Design criteria and test options. Ph.D. Thesis - Georgia Inst. of Tech.

    Science.gov (United States)

    Thomas, J. M.; Hanagud, S.

    1974-01-01

    The design criteria and test options for aerospace structural reliability were investigated. A decision methodology was developed for selecting a combination of structural tests and structural design factors. The decision method involves the use of Bayesian statistics and statistical decision theory. Procedures are discussed for obtaining and updating data-based probabilistic strength distributions for aerospace structures when test information is available and for obtaining subjective distributions when data are not available. The techniques used in developing the distributions are explained.

  17. Validity and Reliability of the U.S. National Cancer Institute's Patient-Reported Outcomes Version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE)

    Science.gov (United States)

    Dueck, Amylou C.; Mendoza, Tito R.; Mitchell, Sandra A.; Reeve, Bryce B.; Castro, Kathleen M.; Rogak, Lauren J.; Atkinson, Thomas M.; Bennett, Antonia V.; Denicoff, Andrea M.; O'Mara, Ann M.; Li, Yuelin; Clauser, Steven B.; Bryant, Donna M.; Bearden, James D.; Gillis, Theresa A.; Harness, Jay K.; Siegel, Robert D.; Paul, Diane B.; Cleeland, Charles S.; Schrag, Deborah; Sloan, Jeff A.; Abernethy, Amy P.; Bruner, Deborah W.; Minasian, Lori M.; Basch, Ethan

    2016-01-01

    Importance Symptomatic adverse events (AEs) in cancer trials are currently reported by clinicians using the National Cancer Institute's (NCI) Common Terminology Criteria for Adverse Events (CTCAE). To integrate the patient perspective, the NCI developed a patient-reported outcomes version of the CTCAE (PRO-CTCAE) to capture symptomatic AEs directly from patients. Objective To assess the construct validity, test-retest reliability, and responsiveness of PRO-CTCAE items. Design Participants completed PRO-CTCAE items on tablet computers in clinic waiting rooms at two visits 1-6 weeks apart. A subset completed PRO-CTCAE items during an additional visit one business day after the first visit. Setting Nine U.S. cancer centers and community oncology practices. Participants 975 adult cancer patients undergoing outpatient chemotherapy and/or radiation enrolled between January 2011 and February 2012. Eligibility required participants to read English and be without clinically significant cognitive impairment. Main Outcome(s) and Measure(s) Primary comparators were clinician-reported Eastern Cooperative Oncology Group Performance Status (ECOG PS) and the European Organisation for Research and Treatment of Cancer Core Quality of Life Questionnaire (QLQ-C30). Results 940/975 (96%) and 852/940 (91%) participants completed PRO-CTCAE items at each visit. 938/940 (99.8%) participants (53% female, median age 59, 32% high school education or less, 17% ECOG PS 2-4) reported having at least one symptom. All PRO-CTCAE items had at least one correlation in the expected direction with a QLQ-C30 scale (111/124 P<.05). Stronger correlations were seen between PRO-CTCAE items and conceptually-related QLQ-C30 domains. Scores for 94/124 PRO-CTCAE items were higher in the ECOG PS 2-4 versus 0-1 group (58/124 P<.05). Overall, 119/124 items met at least one construct validity criterion. Test-retest reliability was acceptable for 36/49 pre-specified items (median intra-class correlation coefficient

  18. NWTS program criteria for mined geologic disposal of nuclear waste: program objectives, functional requirements, and system performance criteria

    International Nuclear Information System (INIS)

    1981-04-01

    At the present time, final repository criteria have not been issued by the responsible agencies. This document describes general objectives, requirements, and criteria that the DOE intends to apply in the interim to the National Waste Terminal Storage (NWTS) Program. These objectives, requirements, and criteria have been developed on the basis of DOE's analysis of what is needed to achieve the National objective of safe waste disposal in an environmentally acceptable and economic manner and are expected to be consistent with anticipated regulatory standards. The qualitative statements in this document address the broad issues of public and occupational health and safety, institutional acceptability, engineering feasibility, and economic considerations. A comprehensive set of criteria, general and project specific, of which these are a part, will constitute a portion of the technical basis for preparation and submittal by the DOE of formal documents to support future license applications for nuclear waste repositories

  19. NWTS program criteria for mined geologic disposal of nuclear waste: program objectives, functional requirements, and system performance criteria

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-04-01

    At the present time, final repository criteria have not been issued by the responsible agencies. This document describes general objectives, requirements, and criteria that the DOE intends to apply in the interim to the National Waste Terminal Storage (NWTS) Program. These objectives, requirements, and criteria have been developed on the basis of DOE's analysis of what is needed to achieve the National objective of safe waste disposal in an environmentally acceptable and economic manner and are expected to be consistent with anticipated regulatory standards. The qualitative statements in this document address the broad issues of public and occupational health and safety, institutional acceptability, engineering feasibility, and economic considerations. A comprehensive set of criteria, general and project specific, of which these are a part, will constitute a portion of the technical basis for preparation and submittal by the DOE of formal documents to support future license applications for nuclear waste repositories.

  20. High efficiency motors - performance, economy and reliability, by optimisation

    Energy Technology Data Exchange (ETDEWEB)

    Caselotti, P.; Conchetto, A.; Tavner, P.J.

    2000-07-01

    The challenge of the efficiency initiatives in North America and the European Union is to improve performance without reducing power-weight by adding materials and increasing cost. This has been the subject of other papers, Haataja et al Ref2, where the key area has been identified as reducing loss. This paper suggests that addressing the fundamental problem of heat transfer in the TEFC machine, in addition to reducing loss will make it possible to improve performance and still provide competitive products. (orig.)

  1. Sensitivity of performance assessment of the engineered barriers to nuances of release rate criteria

    International Nuclear Information System (INIS)

    Oliver, D.L.R.

    1987-01-01

    The United States Nuclear Regulatory Commission (NRC) has established criteria for the long-term performance of proposed high-level waste repositories. As with any regulation, the criteria may be interpreted in several ways. Due to the high capital costs and the emotional political climate associated with any high-level radioactive waste repository, it is important that there be an early consensus regarding interpretations of the criteria, and what assumptions may be used to demonstrate compliance with them. This work uses analytic solutions of mass transport theory to demonstrate how sensitive performance analyses are to various nuances of the NRC release rate criterion for the engineered barriers. The analysis is directed at the proposed repository in basalt at the Hanford site in Washington State

  2. The reliability and utility of spirometry performed on people with asthma in community pharmacies.

    Science.gov (United States)

    Lei Burton, Deborah; LeMay, Kate S; Saini, Bandana; Smith, Lorraine; Bosnic-Anticevich, Sinthia; Southwell, Phillipa; Cooke, Julie; Emmerton, Lynne; Stewart, Kay; Krass, Ines; Reddel, Helen; Armour, Carol

    2015-01-01

    To investigate the reliability and the utility of spirometry generated by community pharmacists participating in two large asthma intervention trials of 892 people. The Pharmacy Asthma Care Program (PACP) and the Pharmacy Asthma Management Service (PAMS) involved up to four visits to the pharmacy over 6 months for counseling and goal setting. Pharmacists performed spirometry according to ATS/ERS guidelines to inform management. The proportion of A-E, F quality tests, as per EasyOne QC grades, were recorded. Lung function results between visits and for participants referred/not referred to their general practitioner on the basis of spirometry were compared. Complete data from 2593 spirometry sessions were recorded, 68.5% of spirometry sessions achieved three acceptable tests with between-test repeatability of 150 ml or less (A or B quality), 96% of spirometry sessions included at least one test that met ATS/ERS acceptability criteria. About 39.1% of participants had FEV1/FVC values below the lower limit of normal (LNN), indicating a respiratory obstruction. As a result of the service, there was a significant increase in FEV1 and FEV1/FVC and asthma control. Lung function values were significantly poorer for participants referred to their general practitioner, compared with those not referred, on the basis of spirometry. Community pharmacists are able to reliably achieve spirometry results meeting ATS/ERS guidelines in people with asthma. Significant improvements in airway obstruction were demonstrated with the pharmacy services. Pharmacists interpreted lung function results to identify airway obstruction for referral, making this a useful technique for review of people with asthma in the community.

  3. The impact of revised DSM-5 criteria on the relative distribution and inter-rater reliability of eating disorder diagnoses in a residential treatment setting.

    Science.gov (United States)

    Thomas, Jennifer J; Eddy, Kamryn T; Murray, Helen B; Tromp, Marilou D P; Hartmann, Andrea S; Stone, Melissa T; Levendusky, Philip G; Becker, Anne E

    2015-09-30

    This study evaluated the relative distribution and inter-rater reliability of revised DSM-5 criteria for eating disorders in a residential treatment program. Consecutive adolescent and young adult females (N=150) admitted to a residential eating disorder treatment facility were assigned both DSM-IV and DSM-5 diagnoses by a clinician (n=14) via routine clinical interview and a research assessor (n=4) via structured interview. We compared the frequency of diagnostic assignments under each taxonomy and by type of assessor. We evaluated concordance between clinician and researcher assignment through inter-rater reliability kappa and percent agreement. Significantly fewer patients received either clinician or researcher diagnoses of a residual eating disorder under DSM-5 (clinician-12.0%; researcher-31.3%) versus DSM-IV (clinician-28.7%; researcher-59.3%), with the majority of reassigned DSM-IV residual cases reclassified as DSM-5 anorexia nervosa. Researcher and clinician diagnoses showed moderate inter-rater reliability under DSM-IV (κ=.48) and DSM-5 (κ=.57), though agreement for specific DSM-5 other specified feeding or eating disorder (OSFED) presentations was poor (κ=.05). DSM-5 revisions were associated with significantly less frequent residual eating disorder diagnoses, but not with reduced inter-rater reliability. Findings support specific dimensions of clinical utility for revised DSM-5 criteria for eating disorders. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Towards Reliable Evaluation of Anomaly-Based Intrusion Detection Performance

    Science.gov (United States)

    Viswanathan, Arun

    2012-01-01

    This report describes the results of research into the effects of environment-induced noise on the evaluation process for anomaly detectors in the cyber security domain. This research was conducted during a 10-week summer internship program from the 19th of August, 2012 to the 23rd of August, 2012 at the Jet Propulsion Laboratory in Pasadena, California. The research performed lies within the larger context of the Los Angeles Department of Water and Power (LADWP) Smart Grid cyber security project, a Department of Energy (DoE) funded effort involving the Jet Propulsion Laboratory, California Institute of Technology and the University of Southern California/ Information Sciences Institute. The results of the present effort constitute an important contribution towards building more rigorous evaluation paradigms for anomaly-based intrusion detectors in complex cyber physical systems such as the Smart Grid. Anomaly detection is a key strategy for cyber intrusion detection and operates by identifying deviations from profiles of nominal behavior and are thus conceptually appealing for detecting "novel" attacks. Evaluating the performance of such a detector requires assessing: (a) how well it captures the model of nominal behavior, and (b) how well it detects attacks (deviations from normality). Current evaluation methods produce results that give insufficient insight into the operation of a detector, inevitably resulting in a significantly poor characterization of a detectors performance. In this work, we first describe a preliminary taxonomy of key evaluation constructs that are necessary for establishing rigor in the evaluation regime of an anomaly detector. We then focus on clarifying the impact of the operational environment on the manifestation of attacks in monitored data. We show how dynamic and evolving environments can introduce high variability into the data stream perturbing detector performance. Prior research has focused on understanding the impact of this

  5. Selection criteria for building performance simulation tools : contrasting architects' and engineers' needs

    NARCIS (Netherlands)

    Attia, S.G.; Hensen, J.L.M.; Beltran, L.; De Herde, A.

    2012-01-01

    This article summarises a study undertaken to reveal potential challenges and opportunities for using building performance simulation (BPS) tools. The article reviews current trends in building simulation and outlines major criteria for BPS tool selection and evaluation based on analysing users'

  6. Drawing students' attention to relevant assessment criteria: effects on self-assessment skills and performance

    NARCIS (Netherlands)

    Fastré, Greet; Van der Klink, Marcel; Sluijsmans, Dominique; Van Merriënboer, Jeroen

    2012-01-01

    Fastré, G. M. J., Van der Klink, M. R., Sluijsmans, D., & Van Merriënboer, J. J. G. (2012). Drawing students’ attention to relevant assessment criteria: effects on self-assessment skills and performance. Journal of Vocational Education & Training, 64(2), 185-198. doi:10.1080/13636820.2011.630537

  7. Interpolation in Time Series : An Introductive Overview of Existing Methods, Their Performance Criteria and Uncertainty Assessment

    NARCIS (Netherlands)

    Lepot, M.J.; Aubin, Jean Baptiste; Clemens, F.H.L.R.

    2017-01-01

    A thorough review has been performed on interpolation methods to fill gaps in time-series, efficiency criteria, and uncertainty quantifications. On one hand, there are numerous available methods: interpolation, regression, autoregressive, machine learning methods, etc. On the other hand, there are

  8. 22 CFR 96.6 - Performance criteria for designation as an accrediting entity.

    Science.gov (United States)

    2010-04-01

    ... other similar functions; (f) Except in the case of a public entity, that it operates independently of... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Performance criteria for designation as an accrediting entity. 96.6 Section 96.6 Foreign Relations DEPARTMENT OF STATE LEGAL AND RELATED SERVICES...

  9. 29 CFR 1926.1001 - Minimum performance criteria for rollover protective structures for designated scrapers, loaders...

    Science.gov (United States)

    2010-07-01

    ... loaders, and motor graders. The vehicle and ROPS as a system shall have the structural characteristics... direction of the load application, measured at the ROPS top edge. Should the operator's seat be offcenter... Society of Automotive Engineers Recommended Practices: SAE J320a, Minimum Performance Criteria for Roll...

  10. A Valid and Reliable Tool to Assess Nursing Students` Clinical Performance

    OpenAIRE

    Mehrnoosh Pazargadi; Tahereh Ashktorab; Sharareh Khosravi; Hamid Alavi majd

    2013-01-01

    Background: The necessity of a valid and reliable assessment tool is one of the most repeated issues in nursing students` clinical evaluation. But it is believed that present tools are not mostly valid and can not assess students` performance properly.Objectives: This study was conducted to design a valid and reliable assessment tool for evaluating nursing students` performance in clinical education.Methods: In this methodological study considering nursing students` performance definition; th...

  11. Health system professionals, attitude towards necessary criteria for hospitals managers, performance assessment

    Directory of Open Access Journals (Sweden)

    ali janati

    2012-09-01

    Materials and Methods: This study was a qualitative research with thematic analysis method. By using semi structured questionnaire with 2 health system experts interview was conducted and 20 experts participated in focus group discussion. After each interview and group discussion withdrawals were checked with participants. The initial interviews were analyzed by two faculty members and then were combined. Results: 7 main themes about necessary criteria for hospital managers, performance assessment were obtained from experts, views. These themes are: skills related to planning, organization and staff performance management, leadership, information management, clinical governance and performance indicators. Conclusion: All participants in the study had a history of hospital management therefore their comments will be an effective step in identifying the criteria for making hospital managers, performance assessment tool. In addition to Professionals, perspectives and studies done in other countries, in order to design this kind of tools, it is necessary to adjust the obtained findings according to the local hospital conditions.

  12. Interpolation in Time Series: An Introductive Overview of Existing Methods, Their Performance Criteria and Uncertainty Assessment

    Directory of Open Access Journals (Sweden)

    Mathieu Lepot

    2017-10-01

    Full Text Available A thorough review has been performed on interpolation methods to fill gaps in time-series, efficiency criteria, and uncertainty quantifications. On one hand, there are numerous available methods: interpolation, regression, autoregressive, machine learning methods, etc. On the other hand, there are many methods and criteria to estimate efficiencies of these methods, but uncertainties on the interpolated values are rarely calculated. Furthermore, while they are estimated according to standard methods, the prediction uncertainty is not taken into account: a discussion is thus presented on the uncertainty estimation of interpolated/extrapolated data. Finally, some suggestions for further research and a new method are proposed.

  13. Development of a business plan for women's health services, using Malcolm Baldrige Performance Excellence Criteria.

    Science.gov (United States)

    Caramanica, L; Maxwell, S; Curry, S

    2000-06-01

    A new process for business planning at Hartford Hospital was needed to achieve critical business results. This article describes the Hospital's use of the Malcolm Baldrige Performance Excellence Criteria as a way to standardize and improve business planning. Women's Health Services is one of Hartford Hospital's "centers for excellence" and one of the first to use these criteria to improve its service. Staff learned how to build their business plan upon a set of core values and concepts such as customer-driven quality, leadership that sets high expectations, continuous improvement and learning, valuing employees, faster response to market demands, management by fact, and a long-range view of the future.

  14. Comparison Criteria and Performance Levels for Soundproofing Panels Made in Different Constructive Variants

    Directory of Open Access Journals (Sweden)

    Ana Gheorghe

    2013-09-01

    Full Text Available This paper presents an analysis of the performance lavels and comparison criteria for panels made from different soundproofing materials, in different constructive variants. Setting the performance level, on the basis of normative and regulatory documents, for soundproofing materials contained inside of noise reduction devices, is determined so that it can be defined, tested and established feasible technical solutions for sound absorbing protection, through a dissemination of obtained results as well for ensuring requirements for implementing the technology transfer for manufacturing.

  15. Validity and reliability of tests determining performance-related components of wheelchair basketball

    NARCIS (Netherlands)

    de Groot, Sonja; Balvers, Inge J.M.; Kouwenhoven, Sanne M.; Janssen, Thomas W.J.

    The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players'

  16. Validity and reliability of tests determining performance-related components of wheelchair basketball

    NARCIS (Netherlands)

    De Groot, Sonja; Balvers, Inge J. M.; Kouwenhoven, Sanne M.; Janssen, Thomas W. J.

    2012-01-01

    The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players'

  17. Reliability database development and plant performance improvement effort at Korea Hydro and Nuclear Power Co

    International Nuclear Information System (INIS)

    Oh, S. J.; Hwang, S. W.; Na, J. H.; Lim, H. S.

    2008-01-01

    Nuclear utilities in recent years have focused on improved plant performance and equipment reliability. In U.S., there is a movement toward process integration. Examples are INPO AP-913 equipment reliability program and the standard nuclear performance model developed by NEI. Synergistic effect from an integrated approach can be far greater than as compared to individual effects from each program. In Korea, PSA for all Korean NPPs (Nuclear Power Plants) has been completed. Plant performance monitoring and improvement is an important goal for KHNP (Korea Hydro and Nuclear Power Company) and a risk monitoring system called RIMS has been developed for all nuclear plants. KHNP is in the process of voluntarily implementing maintenance rule program similar to that in U.S. In the future, KHNP would like to expand the effort to equipment reliability program and to achieve highest equipment reliability and improved plant performance. For improving equipment reliability, the current trend is moving toward preventive/predictive maintenance from corrective maintenance. With the emphasis on preventive maintenance, the failure cause and operation history and environment are important. Hence, the development of accurate reliability database is necessary. Furthermore, the database should be updated regularly and maintained as a living program to reflect the current status of equipment reliability. This paper examines the development of reliability database system and its application of maintenance optimization or Risk Informed Application (RIA). (authors)

  18. Comparison of reading performance tests concerning difficulty of sentences and paragraphs and their reliability

    NARCIS (Netherlands)

    Brussee, T.; van Nispen, R.M.A.; Klerkx, E.M.F.J.; Knol, D.L.; van Rens, G.H.M.B.

    2015-01-01

    In research and practice, sentences or paragraphs of reading tests may be randomly chosen to assess reading performance. This means that in addition to test reliability, all sentences or paragraphs should be reliable and equally difficult to read. The sentences and paragraphs of five (un-)

  19. Performance allocation traceable to regulatory criteria as applied to site characterization work at the Basalt Waste Isolation Project

    International Nuclear Information System (INIS)

    Deju, R.A.; Babad, H.; Bensky, M.S.; Jacobs, G.K.

    1983-01-01

    The Basalt Waste Isolation Project has developed a method for defining in detail the work required to demonstrate the feasibility of emplacing and providing for the safe isolation of nuclear wastes in a repository in the deep basalts at the Hanford Site near Richland, Washington. Criteria analysis allows the identification of areas of significant technical uncertainty or controversy that can be highlighted as issues. A preliminary analysis has been conducted, which, by identifying key radionuclides and allocating performance among the multiple barriers in a repository constructed in a basalt, allows the design and development testing activities at the Basalt Waste Isolation Project to be put into perspective. Application of sophisticated uncertainty analysis techniques will allow refinements in the analysis to be made and to further guide characterization and testing activities. Preliminary results suggest that a repository constructed in basalt will provide for the safe isolation of nuclear wastes in a cost-effective and reliable manner with a high degree of confidence

  20. A Framework for Human Performance Criteria for Advanced Reactor Operational Concepts

    Energy Technology Data Exchange (ETDEWEB)

    Jacques V Hugo; David I Gertman; Jeffrey C Joe

    2014-08-01

    This report supports the determination of new Operational Concept models needed in support of the operational design of new reactors. The objective of this research is to establish the technical bases for human performance and human performance criteria frameworks, models, and guidance for operational concepts for advanced reactor designs. The report includes a discussion of operating principles for advanced reactors, the human performance issues and requirements for human performance based upon work domain analysis and current regulatory requirements, and a description of general human performance criteria. The major findings and key observations to date are that there is some operating experience that informs operational concepts for baseline designs for SFR and HGTRs, with the Experimental Breeder Reactor-II (EBR-II) as a best-case predecessor design. This report summarizes the theoretical and operational foundations for the development of a framework and model for human performance criteria that will influence the development of future Operational Concepts. The report also highlights issues associated with advanced reactor design and clarifies and codifies the identified aspects of technology and operating scenarios.

  1. A proposed framework for establishing integrated cost and performance criteria for environmental technologies: A summary report

    International Nuclear Information System (INIS)

    1994-05-01

    This document presents a summary of results of a joint EPA/DOE project aimed at establishing a suite of standard cost and performance criteria for evaluating environmental cleanup technologies for DOE sites. Project findings include: (1) decisionmakers have quite different perspectives with interests and information needs varying among decisionmaker groups, (2) previous criteria development efforts may be too narrowly focused to apply to all decisionmakers, (3) criteria must include social/political/economic interests of decisionmakers as well as site-specific variations, and (4) there are 5 core questions that all decisionmakers are likely to ask when considering a technology for use at a site. The resource developed in the project offers decisionmakers a first-time comprehensive assessment of major technology evaluation issues

  2. Cryogenics system: strategy to achieve nominal performance and reliable operation

    International Nuclear Information System (INIS)

    Bremer, J.; Brodzinski, K.; Casas, J.; Claudet, S.; Delikaris, D.; Delruelle, N.; Ferlin, G.; Fluder, C.; Perin, A.; Perinic, G.; Pezzetti, M.; Pirotte, O.; Tavian, L.; Wagner, U.

    2012-01-01

    During the LHC operation in 2010 and 2011, the cryogenic system has achieved an availability level fulfilling the overall requirement. To reach this level, the cryogenic system has profited like many other beam-dependent systems from the reduced beam parameters. Therefore, impacts of some failures occurred during the LHC operation were mitigated by using the over-capacity margin, the existing built-in redundancy in between adjacent sector cryogenic plants and the 'cannibalization' of spares on two idle cryogenic plants. These two first years of operation were also crucial to identify the weaknesses of the present cryogenic maintenance plan and new issues like SEUs. After the LS1, nominal beam parameters are expected and the mitigated measures will be less effective or not applicable at all. Consequently, a consolidation plan to improve the MTBF and the MTTR of the LHC cryogenic system is under definition. Concerning shutdown periods, the present cryogenic sectorization imposes some restrictions in the type of interventions (e.g. cryo-magnet removal) which can be done without affecting the operating conditions of the adjacent sector. This creates additional constrains and possible extra down-time in the schedule of the shutdowns including the hardware commissioning. This presentation focuses on the consolidation plan foreseen during the LS1 to improve the performance of the LHC cryogenic system in terms of availability and sectorization. (authors)

  3. Reliability and performance experience with flat-plate photovoltaic modules

    Science.gov (United States)

    Ross, R. G., Jr.

    1982-01-01

    Statistical models developed to define the most likely sources of photovoltaic (PV) array failures and the optimum method of allowing for the defects in order to achieve a 20 yr lifetime with acceptable performance degradation are summarized. Significant parameters were the cost of energy, annual power output, initial cost, replacement cost, rate of module replacement, the discount rate, and the plant lifetime. Acceptable degradation allocations were calculated to be 0.0001 cell failures/yr, 0.005 module failures/yr, 0.05 power loss/yr, a 0.01 rate of power loss/yr, and a 25 yr module wear-out length. Circuit redundancy techniques were determined to offset cell failures using fault tolerant designs such as series/parallel and bypass diode arrangements. Screening processes have been devised to eliminate cells that will crack in operation, and multiple electrical contacts at each cell compensate for the cells which escape the screening test and then crack when installed. The 20 yr array lifetime is expected to be achieved in the near-term.

  4. Multiple Criteria and Multiple Periods Performance Analysis: The Comparison of North African Railways

    Science.gov (United States)

    Sabri, Karim; Colson, Gérard E.; Mbangala, Augustin M.

    2008-10-01

    Multi-period differences of technical and financial performances are analysed by comparing five North African railways over the period (1990-2004). A first approach is based on the Malmquist DEA TFP index for measuring the total factors productivity change, decomposed into technical efficiency change and technological changes. A multiple criteria analysis is also performed using the PROMETHEE II method and the software ARGOS. These methods provide complementary detailed information, especially by discriminating the technological and management progresses by Malmquist and the two dimensions of performance by Promethee: that are the service to the community and the enterprises performances, often in conflict.

  5. Benchmarking the Performance of Construction Procurement Methods against Selection Criteria in Nigeria

    Directory of Open Access Journals (Sweden)

    Stephen Okunlola Ojo

    2009-01-01

    Full Text Available The study developed performance indices by the widely used procurement options in Nigeria on selection criteria. The traditional mean and standardized ratio were used to form the utility coefficients. Results revealed that performance by the procurement options depended on the respondents’ categorization and cost categorization of projects. Public clients ranked the lump sum contracts more able to achieve speed for projects up to N100 million (Naira while the private clients believe it is the design-build. As regards quality, public clients rated the Build-Own-Operate-Transfer (BOOT system as most able to achieve the quality criterion whereas private clients rated design-build for projects up to N100 million (Naira. The study then concluded that, in the Nigerian construction industry participants do not agree on the performance of the procurement options on selection criteria.

  6. Social anxiety disorder diagnostic criteria perform equally across age, comorbid diagnosis, and performance/interaction subtypes.

    Science.gov (United States)

    Crome, Erica; Baillie, Andrew

    2015-01-01

    The prevalence of social anxiety disorder (SAD) is frequently higher in younger age groups and people with other anxiety or mood disorders; however, it is unclear whether these groups have a higher risk for developing SAD or are simply more likely to endorse diagnostic criteria than other people with similar levels of social anxiety. Explicitly testing the assumption all people respond to structured diagnostic interviews in comparable ways (measurement invariance) is essential in ensuring systematic response biases do not create spurious group differences. This research aims to systematically test whether age, comorbidity status, or types of social fears affect responses to a structured diagnostic interview. Responses from 1755 participants in a large-scale survey of mental health in Australia screening into the social phobia/SAD section of the Composite International Diagnostic Interview were used. Three series of multigroup confirmatory factor analyses for categorical data systematically tested for increasingly strict levels of measurement invariance. Overall, patterns of responding to diagnostic criteria were comparable across the groups, supporting assumptions of measurement invariance. Establishment of invariance supports the interpretation of differences between age, comorbidity status, and types of social situations feared as genuine differences in experience as opposed to measurement biases.

  7. Forward lunge as a functional performance test in ACL deficient subjects: test-retest reliability

    DEFF Research Database (Denmark)

    Alkjaer, Tine; Henriksen, Marius; Dyhre-Poulsen, Poul

    2009-01-01

    The forward lunge movement may be used as a functional performance test of anterior cruciate ligament (ACL) deficient and reconstructed subjects. The purposes were 1) to determine the test-retest reliability of a forward lunge in healthy subjects and 2) to determine the required numbers...... of repetitions necessary to yield satisfactory reliability. Nineteen healthy subjects performed four trials of a forward lunge on two different days. The movement time, impulses of the ground reaction forces (IFz, IFy), knee joint kinematics and dynamics during the forward lunge were calculated. The relative...... reliability was determined by calculation of Intraclass Correlation Coefficients (ICC). The IFz, IFy and the positive work of the knee extensors showed excellent reliability (ICC >0.75). All other variables demonstrated acceptable reliability (0.4>ICCreliability increased when more than...

  8. Pump performance and reliability follow-up by the French Safety Authorities

    International Nuclear Information System (INIS)

    Clausner, J.P.; De La Ronciere, X.; Scott de Martinville, E.; Courbiere, P.

    1990-12-01

    This paper will present, through actual examples, the methodology of the performance and reliability safety-related pumps evaluation applied by the French Safety Authorities and the lessons drawn from this evaluation

  9. Impact of scaling on the performance and reliability degradation of metal-contacts in NEMS devices

    KAUST Repository

    Dadgour, Hamed F.; Hussain, Muhammad Mustafa; Cassell, Alan M.; Singh, Navab R.; Banerjee, Kaustav

    2011-01-01

    thoroughly investigated in the literature. Such a study is essential because metal contacts play a critical role in determining the overall performance and reliability of NEMS. Therefore, the comprehensive analytical study presented in this paper highlights

  10. Improved Yield, Performance and Reliability of High-Actuator-Count Deformable Mirrors, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The project team will conduct processing and design research aimed at improving yield, performance, and reliability of high-actuator-count micro-electro-mechanical...

  11. Containment design, performance criteria and research needs for advanced reactor designs

    International Nuclear Information System (INIS)

    Bagdi, G.; Ali, S.; Costello, J

    2004-01-01

    This paper points out some important shifts in the basic expectations in the performance requirements for containment structures and discusses the areas where the containment structure design requirements and acceptance criteria can be integrated with ultimate test based insights. Although there has not been any new reactor construction in the United States for over thirty years, several designs of evolutionary and advanced reactors have already been certified. Performance requirements for containment structures under design basis and severe accident conditions and explicit consideration of seismic margins have been used in the design certification process. In the United States, the containment structure design code is the American Society of Mechanical Engineers, Boiler and Pressure Vessel Code, Section III, Division 1, Subsection NE-Class MC for the steel containment and Section III, Division 2 for reinforced and prestressed concrete reactor vessels and containments. This containment design code was based on the early concept of applying design basis internal pressure and associated load combinations that included the operating basis and safe shutdown earthquake ground motion. These early design criteria served the nuclear industry and the regulatory authorities in maintaining public health and safety. However, these early design criteria do not incorporate the performance criteria related to containment function in an integrated fashion. Research in large scale model testing of containment structures to failure from over pressurization and shake table testing using simulated ground motion, have produced insights related to failure modes and material behavior at failure. The results of this research provide the opportunity to integrate these observations into design and acceptance criteria. This integration process would identify 'gaps' in the present knowledge and future research needs. This knowledge base is important for gleaning risk-informed insights into

  12. Analysis of performance reliability of electrical and electronic equipment of car-tractor

    Directory of Open Access Journals (Sweden)

    Kravchenko О.Р.

    2016-08-01

    Full Text Available The analysis of the operational reliability of electrical and electronic equipment of vehicles, trucks Mercedes-Benz Actros 1844 LS and Volvo FH 1242, conducting international cargo transportation is performed. It is established that the equipment is reliable, which meets modern requirements, but where there is a violation of the resolution. The reason for repair work is constructive and operational factors. Distribution of efficiency and overall performance of operational reliability is retrieved. Items with more bounce are found. Common factors of violation of efficiency cars, trucks in operation, are largely different stages in warranty runs are obtained.

  13. A Fast Optimization Method for Reliability and Performance of Cloud Services Composition Application

    Directory of Open Access Journals (Sweden)

    Zhao Wu

    2013-01-01

    Full Text Available At present the cloud computing is one of the newest trends of distributed computation, which is propelling another important revolution of software industry. The cloud services composition is one of the key techniques in software development. The optimization for reliability and performance of cloud services composition application, which is a typical stochastic optimization problem, is confronted with severe challenges due to its randomness and long transaction, as well as the characteristics of the cloud computing resources such as openness and dynamic. The traditional reliability and performance optimization techniques, for example, Markov model and state space analysis and so forth, have some defects such as being too time consuming and easy to cause state space explosion and unsatisfied the assumptions of component execution independence. To overcome these defects, we propose a fast optimization method for reliability and performance of cloud services composition application based on universal generating function and genetic algorithm in this paper. At first, a reliability and performance model for cloud service composition application based on the multiple state system theory is presented. Then the reliability and performance definition based on universal generating function is proposed. Based on this, a fast reliability and performance optimization algorithm is presented. In the end, the illustrative examples are given.

  14. Determination of performance criteria for high-level solidified nuclear waste

    Energy Technology Data Exchange (ETDEWEB)

    Heckman, R.A.; Holdsworth, T.

    1979-05-07

    To minimize radiological risk from the operation of a waste management system, performance limits on volatilization, particulate dispersion, and dissolution characteristics of solidified high level waste must be specified. The results show clearly that the pre-emplacement environs are more limiting in establishing the waste form performance criteria than the post-emplacement environs. Absolute values of expected risk are very sensitive to modeling assumptions. The transportation and interim storage operations appear to be most limiting in determining the performance characteristics required. The expected values of risk do not rely upon the repositories remaining intact over the potentially hazardous lifetime of the waste.

  15. Determination of performance criteria for high-level solidified nuclear waste

    International Nuclear Information System (INIS)

    Heckman, R.A.; Holdsworth, T.

    1979-01-01

    To minimize radiological risk from the operation of a waste management system, performance limits on volatilization, particulate dispersion, and dissolution characteristics of solidified high level waste must be specified. The results show clearly that the pre-emplacement environs are more limiting in establishing the waste form performance criteria than the post-emplacement environs. Absolute values of expected risk are very sensitive to modeling assumptions. The transportation and interim storage operations appear to be most limiting in determining the performance characteristics required. The expected values of risk do not rely upon the repositories remaining intact over the potentially hazardous lifetime of the waste

  16. Proposed waste form performance criteria and testing methods for low-level mixed waste

    International Nuclear Information System (INIS)

    Franz, E.M.; Fuhrmann, M.; Bowerman, B.

    1995-01-01

    Proposed waste form performance criteria and testing methods were developed as guidance in judging the suitability of solidified waste as a physico-chemical barrier to releases of radionuclides and RCRA regulated hazardous components. The criteria follow from the assumption that release of contaminants by leaching is the single most important property for judging the effectiveness of a waste form. A two-tier regimen is proposed. The first tier consists of a leach test designed to determine the net, forward leach rate of the solidified waste and a leach test required by the Environmental Protection Agency (EPA). The second tier of tests is to determine if a set of stresses (i.e., radiation, freeze-thaw, wet-dry cycling) on the waste form adversely impacts its ability to retain contaminants and remain physically intact. In the absence of site-specific performance assessments (PA), two generic modeling exercises are described which were used to calculate proposed acceptable leachates

  17. Reliability and validity of the DSM-IV-TR and proposed DSM-5 criteria for pedophilia: Implications for the ICD-11 and the next DSM.

    Science.gov (United States)

    Seto, Michael C; Fedoroff, J Paul; Bradford, John M; Knack, Natasha; Rodrigues, Nicole C; Curry, Susan; Booth, Brad; Gray, Jonathan; Cameron, Colin; Bourget, Dominique; Messina, Sarina; James, Elizabeth; Watson, Diane; Gulati, Sanjiv; Balmaceda, Rufino; Ahmed, Adekunle G

    We tested the inter-rater reliability and criterion-related validity of the DSM-IV-TR pedophilia diagnosis and proposed DSM-5 pedohebephilia diagnosis in a sample of 79 men who had committed child pornography offenses, contact sexual offenses against children, or who were referred because of concerns about whether they had a sexual interest in children. Participants were evaluated by two independent psychiatrists with an interview and questionnaire regarding demographic characteristics, sexual history, and self-reported sexual interests; they also completed phallometric and visual reaction time testing. Kappa was .59 for ever meeting DSM-IV-TR criteria for pedophilia and .52 for ever meeting the proposed DSM-5 criteria for pedohebephilia. Ever meeting DSM-IV-TR diagnosis was significantly related to self-reported index of sexual interest in children (highest AUC=.81, 95% CI=.70-.91, pDSM-5 "diagnosis" was similarly related to self-report (AUC=.84, 95% CI=.74-.94, pDSM-5 criteria, we believe these results suggest the revision of DSM-5 and development of ICD-11 could benefit from drawing on the current DSM-5 criteria, which are essentially the same as DSM-IV-TR except for a distinction between having a paraphilia (the interest) and a paraphilic disorder (the paraphilia plus clinically significant distress or impairment). Copyright © 2016. Published by Elsevier Ltd.

  18. Abiquiu Dam and Reservoir, Rio Grande Basin, Rio Chama, New Mexico. Embankment Criteria and Performance Report.

    Science.gov (United States)

    1987-04-01

    EMBANKMENT CRITERIA AND PERFORMANCE REPORT PERTINENT DATA 1. General Data. LOCATION: Rio Arriba County, New Mexico, on the Rio Chama at river mile 33. PURPOSE...is located across the Rio Chama, approximately 30 miles upstream from its confluence with the Rio Grande, in Rio Arriba County, New Mexico. The dam is...6600- 4 i ’. 6600 65060- -60 6600- a + v6500s-go FA**v~w -6500 6300- 60 - ~ ~ ~ wo Ala filll------------------ EMBNKEN SECTION62 *LDN WOR SAFEL VAIE

  19. Can Physicians Identify Inappropriate Nuclear Stress Tests? An Examination of Inter-rater Reliability for the 2009 Appropriate Use Criteria for Radionuclide Imaging

    Science.gov (United States)

    Ye, Siqin; Rabbani, LeRoy E.; Kelly, Christopher R.; Kelly, Maureen R.; Lewis, Matthew; Paz, Yehuda; Peck, Clara L.; Rao, Shaline; Bokhari, Sabahat; Weiner, Shepard D.; Einstein, Andrew J.

    2014-01-01

    Background We sought to determine inter-rater reliability of the 2009 Appropriate Use Criteria (AUC) for radionuclide imaging (RNI) and whether physicians at various levels of training can effectively identify nuclear stress tests with inappropriate indications. Methods and Results Four hundred patients were randomly selected from a consecutive cohort of patients undergoing nuclear stress testing at an academic medical center. Raters with different levels of training (including cardiology attending physicians, cardiology fellows, internal medicine hospitalists, and internal medicine interns) classified individual nuclear stress tests using the 2009 AUC. Consensus classification by two cardiologists was considered the operational gold standard, and sensitivity and specificity of individual raters for identifying inappropriate tests was calculated. Inter-rater reliability of the AUC was assessed using Cohen’s kappa statistics for pairs of different raters. The mean age of patients was 61.5 years; 214 (54%) were female. The cardiologists rated 256 (64%) of 400 NSTs as appropriate, 68 (18%) as uncertain, 55 (14%) as inappropriate; 21 (5%) tests were unable to be classified. Inter-rater reliability for non-cardiologist raters was modest (unweighted Cohen’s kappa, 0.51, 95% confidence interval, 0.45 to 0.55). Sensitivity of individual raters for identifying inappropriate tests ranged from 47% to 82%, while specificity ranged from 85% to 97%. Conclusions Inter-rater reliability for the 2009 AUC for RNI is modest, and there is considerable variation in the ability of raters at different levels of training to identify inappropriate tests. PMID:25563660

  20. The 2010 American college of rheumatology fibromyalgia survey diagnostic criteria and symptom severity scale is a valid and reliable tool in a French speaking fibromyalgia cohort

    Directory of Open Access Journals (Sweden)

    Fitzcharles Mary-Ann

    2012-09-01

    Full Text Available Abstract Background Fibromyalgia (FM is a pain condition with associated symptoms contributing to distress. The Fibromyalgia Survey Diagnostic Criteria and Severity Scale (FSDC is a patient-administered questionnaire assessing diagnosis and symptom severity. Locations of body pain measured by the Widespread Pain Index (WPI, and the Symptom Severity scale (SS measuring fatigue, unrefreshing sleep, cognitive and somatic complaints provide a score (0–31, measuring a composite of polysymptomatic distress. The reliability and validity of the translated French version of the FSDC was evaluated. Methods The French FSDC was administered twice to 73 FM patients, and was correlated with measures of symptom status including: Fibromyalgia Impact Questionnaire (FIQ, Health Assessment Questionnaire (HAQ, McGill Pain Questionnaire (MPQ, and a visual analogue scale (VAS for global severity and pain. Test-retest reliability, internal consistency, and construct validity were evaluated. Results Test-retest reliability was between .600 and .888 for the 25 single items of the FSDC, and .912 for the total FSDC, with all correlations significant (p  Conclusions The French FSDC is a valid instrument in French FM patients with reliability and construct validity. It is easily completed, simple to score, and has the potential to become the standard for measurement of polysymptomatic distress in FM.

  1. reliability reliability

    African Journals Online (AJOL)

    eobe

    Corresponding author, Tel: +234-703. RELIABILITY .... V , , given by the code of practice. However, checks must .... an optimization procedure over the failure domain F corresponding .... of Concrete Members based on Utility Theory,. Technical ...

  2. [Analysis of microalbuminuria with immunonephelometry and high performance liquid chromatography. Evaluation of new criteria].

    Science.gov (United States)

    Markó, Lajos; Molnár, Gergo Attila; Wagner, Zoltán; Koszegi, Tamás; Matus, Zoltán; Mohás, Márton; Kuzma, Mónika; Szijártó, István András; Wittmann, István

    2008-01-13

    Hypertension as well as type 2 diabetes mellitus is a major factor in population mortality. Both diseases damage the endothelium, the early sign of which is microalbuminuria, which can be screened by dipstick and can be diagnosed by using immuno-based and high performance liquid chromatography methods. Using high performance liquid chromatography, the non-immunoreactive albumin can be detected as well. The authors aimed at the examination of albuminuria in the case of immunonephelometrically negative patients with high performance liquid chromatography, in diabetic and hypertensive and non-diabetic hypertensive populations. The authors also wanted to compare the present (albumin-creatinine ratio: male: > or =2.5 mg/mmol, female: > or =3.5 mg/mmol) and a new criteria of the Heart Outcomes Prevention Evaluation study (patients without diabetes: immunological method, > or =0.7 mg/mmol; high performance liquid chromatography, > or =3.1 mg/mmol; individuals with diabetes: immunological method, > or =1.4 mg/mmol; high performance liquid chromatography, > or =5.2 mg/mmol) of microalbuminuria. Examination of fresh urines of 469 microalbuminuria negative patients by dipstick were performed by immunonephelometry. Patients, who were microalbuminuria negative by immunonephelometry as well, were further analyzed by high performance liquid chromatography using the Accumintrade mark Kit, based on size-exclusion chromatography. Three times higher albuminuria were found with high performance liquid chromatography than with immunonephelometry. The intraindividual coefficient of variation did not differ in the two methods (37 +/- 31% vs. 40 +/- 31%, p = 0.869; immunonephelometry vs. high performance liquid chromatography; mean +/- standard deviation). Using the present criteria for microalbuminuria, 43% of immunonephelometrically negative patients proved to be microalbuminuric by high performance liquid chromatography. Using the new criteria of the Heart Outcomes Prevention

  3. Performance and reliability of TPE-2 device with pulsed high power source

    International Nuclear Information System (INIS)

    Sato, Y.; Takeda, S.; Kiyama, S.

    1987-01-01

    The performance and the reliability of TPE-2 device with pulsed high power sources are described. To obtain the stable high beta plasma, the reproducibility and the reliability of the pulsed power sources must be maintained. A new power crowbar system with high efficiency and the switches with low jitter time are adopted to the bank system. A monitor system which always watches the operational states of the switches is developed too, and applied for the fast rising capacitor banks of TPE-2 device. The reliable operation for the bank has been realized, based on the data of switch monitor system

  4. Laboratory-performance criteria for in situ waste-stabilization materials

    International Nuclear Information System (INIS)

    Shaw, P.; Weidner, J.

    1996-01-01

    The Department of Energy (DOE) Landfill Stabilization Focus Area is investigating a variety of in situ placement methods, grout materials, and characterization techniques for the stabilization of buried low-level transuranic-contaminated waste at Department of Energy sites. In situ stabilization involves underground injection or placement of substances to isolate, treat, or contain buried contaminants. Performance criteria were developed to evaluate various candidate stabilization materials for both long-term stabilization and interim stabilization or retrieval. The criteria are go/no-go, ready, and preliminary. The criterion go/no-go eliminates technologies that are not applicable for in situ treatment of buried waste. The criterion ready indicates that the technology is sufficiently developed and proven to be field demonstrated full-scale. The criterion preliminary indicates the prospective technologies to be potentially applicable to in situ buried waste stabilization, but further development is needed before the technology is ready for field-scale demonstration

  5. Reliability modeling of degradation of products with multiple performance characteristics based on gamma processes

    International Nuclear Information System (INIS)

    Pan Zhengqiang; Balakrishnan, Narayanaswamy

    2011-01-01

    Many highly reliable products usually have complex structure, with their reliability being evaluated by two or more performance characteristics. In certain physical situations, the degradation of these performance characteristics would be always positive and strictly increasing. In such a case, the gamma process is usually considered as a degradation process due to its independent and non-negative increments properties. In this paper, we suppose that a product has two dependent performance characteristics and that their degradation can be modeled by gamma processes. For such a bivariate degradation involving two performance characteristics, we propose to use a bivariate Birnbaum-Saunders distribution and its marginal distributions to approximate the reliability function. Inferential method for the corresponding model parameters is then developed. Finally, for an illustration of the proposed model and method, a numerical example about fatigue cracks is discussed and some computational results are presented.

  6. Reliability and validity of match performance analysis in soccer : a multidimensional qualitative evaluation of opponent interaction

    OpenAIRE

    Tenga, Albin

    2010-01-01

    Avhandling (doktorgrad) – Norges idrettshøgskole, 2010. Match performance analysis is widely used as a method for studying technical, tactical and physical aspects of player and team performance in a soccer match. Therefore, ensuring the validity and reliability of the collected data is important for match performance analysis to meet its intents and purposes effectively. However, most studies on soccer match performance use unidimensional frequency data based on analyses done ...

  7. Embedded Sensors and Controls to Improve Component Performance and Reliability Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Kisner, R.; Melin, A.; Burress, T.; Fugate, D.; Holcomb, D.; Wilgen, J.; Miller, J.; Wilson, D.; Silva, P.; Whitlow, L.; Peretz, F.

    2012-09-15

    The objective of this project is to demonstrate improved reliability and increased performance made possible by deeply embedding instrumentation and controls (I&C) in nuclear power plant (NPP) components and systems. The project is employing a highly instrumented canned rotor, magnetic bearing, fluoride salt pump as its I&C technology demonstration platform. I&C is intimately part of the basic millisecond-by-millisecond functioning of the system; treating I&C as an integral part of the system design is innovative and will allow significant improvement in capabilities and performance. As systems become more complex and greater performance is required, traditional I&C design techniques become inadequate and more advanced I&C needs to be applied. New I&C techniques enable optimal and reliable performance and tolerance of noise and uncertainties in the system rather than merely monitoring quasistable performance. Traditionally, I&C has been incorporated in NPP components after the design is nearly complete; adequate performance was obtained through over-design. By incorporating I&C at the beginning of the design phase, the control system can provide superior performance and reliability and enable designs that are otherwise impossible. This report describes the progress and status of the project and provides a conceptual design overview for the platform to demonstrate the performance and reliability improvements enabled by advanced embedded I&C.

  8. The Reliability of In-Training Assessment when Performance Improvement Is Taken into Account

    Science.gov (United States)

    van Lohuizen, Mirjam T.; Kuks, Jan B. M.; van Hell, Elisabeth A.; Raat, A. N.; Stewart, Roy E.; Cohen-Schotanus, Janke

    2010-01-01

    During in-training assessment students are frequently assessed over a longer period of time and therefore it can be expected that their performance will improve. We studied whether there really is a measurable performance improvement when students are assessed over an extended period of time and how this improvement affects the reliability of the…

  9. Prevalence and Diagnostic Performance of Isolated and Combined NEXUS Chest CT Decision Criteria.

    Science.gov (United States)

    Raja, Ali S; Mower, William R; Nishijima, Daniel K; Hendey, Gregory W; Baumann, Brigitte M; Medak, Anthony J; Rodriguez, Robert M

    2016-08-01

    The use of chest computed tomography (CT) to evaluate emergency department patients with adult blunt trauma is rising. The NEXUS Chest CT decision instruments are highly sensitive identifiers of adult blunt trauma patients with thoracic injuries. However, many patients without injury exhibit one of more of the criteria so cannot be classified "low risk." We sought to determine screening performance of both individual and combined NEXUS Chest CT criteria as predictors of thoracic injury to inform chest CT imaging decisions in "non-low-risk" patients. This was a secondary analysis of data on patients in the derivation and validation cohorts of the prospective, observational NEXUS Chest CT study, performed September 2011 to May 2014 in 11 Level I trauma centers. Institutional review board approval was obtained at all study sites. Adult blunt trauma patients receiving chest CT were included. The primary outcome was injury and major clinical injury prevalence and screening performance in patients with combinations of one, two, or three of seven individual NEXUS Chest CT criteria. Across the 11 study sites, rates of chest CT performance ranged from 15.5% to 77.2% (median = 43.6%). We found injuries in 1,493/5,169 patients (28.9%) who had chest CT; 269 patients (5.2%) had major clinical injury (e.g., pneumothorax requiring chest tube). With sensitivity of 73.7 (95% confidence interval [CI] = 68.1 to 78.6) and specificity of 83.9 (95% CI = 83.6 to 84.2) for major clinical injury, abnormal chest-x-ray (CXR) was the single most important screening criterion. When patients had only abnormal CXR, injury and major clinical injury prevalences were 60.7% (95% CI = 52.2% to 68.6%) and 12.9% (95% CI = 8.3% to 19.4%), respectively. Injury and major clinical injury prevalences when any other single criterion alone (other than abnormal CXR) was present were 16.8% (95% CI = 15.2% to 18.6%) and 1.1% (95% CI = 0.1% to 1.8%), respectively. Injury and major clinical injury prevalences

  10. On the choice of performance assessment criteria and their impact on the overall system performance

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Green, Torben

    2010-01-01

    capacity gap issue in the supermarket refrigeration systems is used as a case study to elaborate on the problem through employment of both real life field data as well as simulation data. A performance function that can capture the compressor capacity gap problem is presented in the paper and used...... to evaluate both data from the real supermarket system and the data generated by the simulation model....

  11. Reliability of EP3OS symptom criteria and nasal endoscopy in the assessment of chronic rhinosinusitis--a GA² LEN study.

    Science.gov (United States)

    Tomassen, P; Newson, R B; Hoffmans, R; Lötvall, J; Cardell, L O; Gunnbjörnsdóttir, M; Thilsing, T; Matricardi, P; Krämer, U; Makowska, J S; Brozek, G; Gjomarkaj, M; Howarth, P; Loureiro, C; Toskala, E; Fokkens, W; Bachert, C; Burney, P; Jarvis, D

    2011-04-01

    The European Position Paper on Rhinosinusitis and Nasal Polyps (EP3OS) incorporates symptomatic, endoscopic, and radiologic criteria in the clinical diagnosis of chronic rhinosinusitis (CRS), while in epidemiological studies, the definition is based on symptoms only. We aimed to assess the reliability and validity of a symptom-based definition of CRS using data from the GA(2) LEN European survey. On two separate occasions, 1700 subjects from 11 centers provided information on symptoms of CRS, allergic rhinitis, and asthma. CRS was defined by the epidemiological EP3OS symptom criteria. The difference in prevalence of CRS between two study points, the standardized absolute repeatability, and the chance-corrected repeatability (kappa) were determined. In two centers, 342 participants underwent nasal endoscopy. The association of symptom-based CRS with endoscopy and self-reported doctor-diagnosed CRS was assessed. There was a decrease in prevalence of CRS between the two study phases, and this was consistent across all centers (-3.0%, 95% CI: -5.0 to -1.0%, I(2) = 0). There was fair to moderate agreement between the two occasions (kappa = 39.6). Symptom-based CRS was significantly associated with positive endoscopy in nonallergic subjects, and with self-reported doctor-diagnosed CRS in all subjects, irrespective of the presence of allergic rhinitis. Our findings suggest that a symptom-based definition of CRS, according to the epidemiological part of the EP3OS criteria, has a moderate reliability over time, is stable between study centers, is not influenced by the presence of allergic rhinitis, and is suitable for the assessment of geographic variation in prevalence of CRS. © 2010 John Wiley & Sons A/S.

  12. Reliability, resilience and vulnerability criteria for the evaluation of time-dependent health risks: A hypothetical case study of wellhead protection

    Science.gov (United States)

    Rodak, C. M.; Silliman, S. E.; Bolster, D.

    2012-12-01

    A hypothetical case study of groundwater contaminant protection was carried out using time-dependent health risk calculations. The case study focuses on a hypothetical zoning project for parcels of land around a well field in northern Indiana, where the control of cancer risk relative to a mandated cancer risk threshold is of concern in the management strategy. Within our analysis, we include both uncertainty in the subsurface transport and variability in population behavior in the calculation of time-dependent health risks. From these results we introduce risk maps, a visual representation of the probability of an unacceptable health risk as a function of population behavior and the time at which exposure to the contaminant begins. We also evaluate the time-dependent risks with three criteria from water resource literature: reliability, resilience, and vulnerability (RRV). With respect to health risk from a groundwater well, the three criteria determine: the probability that a well produces safe water (reliability), the probability that a contaminated well returns to an uncontaminated state within a specified time interval (resilience), and the overall severity in terms of health impact of the contamination at a well head (vulnerability). The results demonstrate that the distributions of RRV values for each parcel of land are linked to the time-dependent concentration profile of the contaminant at the well, and the toxicological characteristics of the contaminant. The proposed time-dependent risk calculation expands on current techniques to include a continuous exposure start time, capable of reproducing the maximum risk while providing information on the severity and duration of health risks. Overall this study suggests that, especially in light of the inherent complexity of health-groundwater systems, RRV are viable criteria for relatively simple and effective evaluation of time-dependent health risk. It is argued that the RRV approach, as applied to

  13. Iranian Expert Opinion about Necessary Criteria for Hospitals Management Performance Assessments

    Directory of Open Access Journals (Sweden)

    Elham Dadgar

    2012-12-01

    Full Text Available Background: Managers in the hospital should have enough managerial skill to be coordinated with the complex environment. Defining a competency framework assessment for hospital man-agement will help to establish core competencies for hospital managers. The aim of this study was to develop concrete and suitable performance assessment criteria using expert's view.Methods: In this qualitative study in total, 20 professionals participated in the interview and Fo-cus Group Discussions (FGD. Two of informants were interviewed and 18 professionals par-ticipants in three focus group discussions. Discussions and interviews were well planned, the FGD environments were suitable and after interviews completion the notes were checked with participant for completeness. Thematic analysis method was used for the analysis of qualitative data.Results: Findings from 3 FGDs and 2 semi structured interviews done with 20 professionals were categorized accordance to themes. The findings were classified in 7 major and 41 sub themes. The major themes include competency related to planning, organization and staff per-formance management, leadership, information management, and clinical governance and per-formance indicators.Conclusion: All participants had hospital administration experience; so their explanation impor-tant in identifying the criteria and developing hospital managers’ performance assessment tool. In addition to professional perspectives and studies done in other countries, in order to design this kind of tools, it is necessary to adopt the obtained findings to the local hospital conditions.

  14. Reliability and Validity of the Turkish Version of the Job Performance Scale Instrument.

    Science.gov (United States)

    Harmanci Seren, Arzu Kader; Tuna, Rujnan; Eskin Bacaksiz, Feride

    2018-02-01

    Objective measurement of the job performance of nursing staff using valid and reliable instruments is important in the evaluation of healthcare quality. A current, valid, and reliable instrument that specifically measures the performance of nurses is required for this purpose. The aim of this study was to determine the validity and reliability of the Turkish version of the Job Performance Instrument. This study used a methodological design and a sample of 240 nurses working at different units in four hospitals in Istanbul, Turkey. A descriptive data form, the Job Performance Scale, and the Employee Performance Scale were used to collect data. Data were analyzed using IBM SPSS Statistics Version 21.0 and LISREL Version 8.51. On the basis of the data analysis, the instrument was revised. Some items were deleted, and subscales were combined. The Turkish version of the Job Performance Instrument was determined to be valid and reliable to measure the performance of nurses. The instrument is suitable for evaluating current nursing roles.

  15. Design of thermoelectric modules for both mechanical reliability and performance using FE simulation

    DEFF Research Database (Denmark)

    Sarhadi, Ali; Bjørk, Rasmus; Pryds, Nini

    for these two objectives. The current study deals with FE simulation of the TE modules to optimize their geometrical dimension in terms of mechanical reliability and performance. First, FE simulation of a TE module consisting of bismuth telluride alloys is carried out and the induced thermal stresses, output......, the geometrical dimensions of the TE elements for both mechanical reliability and performance are optimized to obtain a compromise design. The present work provides a basis for optimizing the TE modules in terms of their life time and performance.......Thermo-mechanical modeling of the TE modules provides an efficient tool for assessing the mechanical strength of the modules against the induced thermal stresses and subsequently optimizing them in terms of the mechanical reliability. However, the design of TE modules in terms of mechanical...

  16. Integrated shape and material selection for single and multi-performance criteria

    International Nuclear Information System (INIS)

    Singh, Jasveer; Mirjalili, Vahid; Pasini, Damiano

    2011-01-01

    Research highlights: → The method of shape transformers is extended to torsional stiffness and combined load design. → The method is generalized for multi-criteria selection of shape and material. → Performance charts are presented for single and multi-objective selection of cross-section shape and material. → A four quadrant performance chart is presented to visualize the relation between objective function space and design variable space. -- Abstract: A shape and material selection method, based on the concept of shape transformers, has been recently introduced to characterize the mass efficiency of lightweight beams under bending and shear. This paper extends this method to deal with the case of torsional stiffness design, and generalize it to single and multi-crieria selection of lightweight shafts subjected to a combination of bending, shear, and torsional load. The novel feature of the paper is the useful integration of shape and material to model and visualize multi-objective selection problems. The scheme is centered on concept selection in structural design, and hinges on measures that govern the shape properties of a cross-section regardless of its size. These measures, referred as shape transformers, can classify shapes in a way similar to material classification. The procedure is exemplified by considering torsional stiffness as a constraint. The performance charts are developed for single and multi-criteria to visualize in a glance the whole range of cross-sectional shapes for each material. Each design chart is explained with a brief example.

  17. Device Performance and Reliability Improvements of AlGaBN/GaN/Si MOSFET

    Science.gov (United States)

    2016-02-04

    AFRL-AFOSR-JP-TR-2016-0037 Device Performance and Reliablity Improvements of AlGaBN/GaN/Si MOSFET Robert Wallace UNIVERSITY OF TEXAS AT DALLAS Final...GaN/Si MOSFET 5a.  CONTRACT NUMBER 5b.  GRANT NUMBER FA2386-14-1-4069 5c.  PROGRAM ELEMENT NUMBER 61102F 6. AUTHOR(S) Robert Wallace 5d.  PROJECT...AOARD Grant FA2386-14-1-4069 Device Performance and Reliability Improvements of AlGaN/GaN/Si MOSFET US 12 month extension (2014 – 2015) for current

  18. Performance-based ECCS cladding acceptance criteria: A new simulation approach

    International Nuclear Information System (INIS)

    Zoino, A.; Alfonsi, A.; Rabiti, C.; Szilard, R.H.; Giannetti, F.; Caruso, G.

    2017-01-01

    Highlights: • A new methodology to demonstrate compliance with the new ECCS acceptance criteria is described. • A wide spectrum of fuel rod initial burnup states can be analysed in the design phase. • The coupled suite PHISICS/RELAP5-3D has been used in the analyses. • A demo simulation of the equilibrium cycle, load-following and a LOCA analysis has been performed. - Abstract: The U.S. Nuclear Regulatory Commission is currently proposing rulemaking to revise the Loss Of Coolant Accident (LOCA) and therefore the Emergency Core Cooling System (ECCS) acceptance criteria, to include the effects of higher burnup on cladding performance as well as to address other technical issues. As motivated by the new rule, the need to use advanced cladding designs may be a result. A loss of operational margin may result due to the more restrictive cladding embrittlement criteria. Initial and future compliance with the rule may significantly increase vendor workload and licensee cost, as a spectrum of fuel rod initial burnup states may need to be analyzed to demonstrate compliance. Consequently, there will be an increased focus on licensee decision making related to LOCA analysis to minimize cost and impact, and to manage margin. The study here presented has been part of a big project used to investigate technical issues and approaches for future industrial applications within the Risk-Informed Safety Margin Characterization (RISMC) Pathway. Specifically, the primary aim of this study is to lay out a roadmap to demonstrate the application of the new methodology. The present analysis shows a simplified version of the methodology of an industrial application on the Core Design and the Multi-Cycle Analysis.

  19. Human Reliability Assessment and Human Performance Evaluation: Research and Analysis Activities at the U.S. NRC

    International Nuclear Information System (INIS)

    Ramey-Smith, A.M.

    1998-01-01

    The author indicates the themes of the six programs identified by the US NRC mission on human performance and human reliability activities. They aim at developing the technical basis to support human performance, at developing and updating a model of human performance and human reliability, at fostering national and international dialogue and cooperation efforts on human performance evaluation, at conducting operating events analysis and database development, and at providing support to human performance and human reliability inspection

  20. Performance criteria for EM rail launchers with solid or transition armatures and laminated rails

    International Nuclear Information System (INIS)

    James, T.E.

    1991-01-01

    Velocity limitations of EM Rail Launchers with solid armatures due to the velocity skin-effect are assessed for a range of homogeneous materials (copper, aluminium, molybdenum and tungsten). Performance criteria as limited by armature melting in the region adjacent to the rail/armature contact surface and by rail surface melting are deduced analytically based on defined electro-thermal reference conditions. The performance criteria predict the reference transition velocity at which the solid contact surface changes to mainly a melted contact surface which is shown to be a fundamental property of the materials. The paper shows that the critical factors in obtaining a high transition velocity are a relatively high resistivity armature material combined with high temperature rail surface coatings. For example a transition velocity of >2.0 km/s for a molybdenum armature and a tungsten rail surface coating on a copper rail are predicted compared with <0.5 km/s for the aluminium/copper combination frequently used

  1. Correlations between PANCE performance, physician assistant program grade point average, and selection criteria.

    Science.gov (United States)

    Brown, Gina; Imel, Brittany; Nelson, Alyssa; Hale, LaDonna S; Jansen, Nick

    2013-01-01

    The purpose of this study was to examine correlations between first-time Physician Assistant National Certifying Exam (PANCE) scores and pass/fail status, physician assistant (PA) program didactic grade point average (GPA), and specific selection criteria. This retrospective study evaluated graduating classes from 2007, 2008, and 2009 at a single program (N = 119). There was no correlation between PANCE performance and undergraduate grade point average (GPA), science prerequisite GPA, or health care experience. There was a moderate correlation between PANCE pass/fail and where students took science prerequisites (r = 0.27, P = .003) but not with the PANCE score. PANCE scores were correlated with overall PA program GPA (r = 0.67), PA pharmacology grade (r = 0.68), and PA anatomy grade (r = 0.41) but not with PANCE pass/fail. Correlations between selection criteria and PANCE performance were limited, but further research regarding the influence of prerequisite institution type may be warranted and may improve admission decisions. PANCE scores and PA program GPA correlations may guide academic advising and remediation decisions for current students.

  2. A new approach for reliability analysis with time-variant performance characteristics

    International Nuclear Information System (INIS)

    Wang, Zequn; Wang, Pingfeng

    2013-01-01

    Reliability represents safety level in industry practice and may variant due to time-variant operation condition and components deterioration throughout a product life-cycle. Thus, the capability to perform time-variant reliability analysis is of vital importance in practical engineering applications. This paper presents a new approach, referred to as nested extreme response surface (NERS), that can efficiently tackle time dependency issue in time-variant reliability analysis and enable to solve such problem by easily integrating with advanced time-independent tools. The key of the NERS approach is to build a nested response surface of time corresponding to the extreme value of the limit state function by employing Kriging model. To obtain the data for the Kriging model, the efficient global optimization technique is integrated with the NERS to extract the extreme time responses of the limit state function for any given system input. An adaptive response prediction and model maturation mechanism is developed based on mean square error (MSE) to concurrently improve the accuracy and computational efficiency of the proposed approach. With the nested response surface of time, the time-variant reliability analysis can be converted into the time-independent reliability analysis and existing advanced reliability analysis methods can be used. Three case studies are used to demonstrate the efficiency and accuracy of NERS approach

  3. Performance measurement for supply chain management and evaluation criteria determination for reverse supply chain management

    Science.gov (United States)

    Kongar, N. Elif

    2004-12-01

    Today, since customers are able to obtain similar-quality products for similar prices, the lead time has become the only preference criterion for most of the consumers. Therefore, it is crucial that the lead time, i.e., the time spent from the raw material phase till the manufactured good reaches the customer, is minimized. This issue can be investigated under the title of Supply Chain Management (SCM). An efficiently managed supply chain can lead to reduced response time for customers. To achieve this, continuous observation of supply chain efficiency, i.e., a constant performance evaluation of the current SCM is required. Widely used conventional performance measurement methods lack the ability to evaluate a SCM since the supply chain is a dynamic system that requires a more thorough and flexible performance measurement technique. Balanced Scorecard (BS) is an efficient tool for measuring the performance of dynamic systems and has a proven capability of providing the decision makers with the appropriate feedback data. In addition to SCM, a relatively new management field, namely reverse supply chain management (RSCM), also necessitates an appropriate evaluation approach. RSCM differs from SCM in many aspects, i.e., the criteria used for evaluation, the high level of uncertainty involved etc., not allowing the usage of identical evaluation techniques used for SCM. This study proposes a generic Balanced Scorecard to measure the performance of supply chain management while defining the appropriate performance measures for SCM. A scorecard prototype, ESCAPE, is presented to demonstrate the evaluation process.

  4. Performance of Different Diagnostic Criteria for Familial Mediterranean Fever in Children with Periodic Fevers : Results from a Multicenter International Registry

    NARCIS (Netherlands)

    Demirkaya, Erkan; Saglam, Celal; Turker, Turker; Koné-Paut, Isabelle; Woo, Pat; Doglio, Matteo; Amaryan, Gayane; Frenkel, Joost; Uziel, Yosef; Insalaco, Antonella; Cantarini, Luca; Hofer, Michael; Boiu, Sorina; Duzova, Ali; Modesto, Consuelo; Bryant, Annette; Rigante, Donato; Papadopoulou-Alataki, Efimia; Guillaume-Czitrom, Severine; Kuemmerle-Deschner, Jasmine; Neven, Bénédicte; Lachmann, Helen; Martini, Alberto; Ruperto, Nicolino; Gattorno, Marco; Ozen, Seza

    2015-01-01

    OBJECTIVE: Our aims were to validate the pediatric diagnostic criteria in a large international registry and to compare them with the performance of previous criteria for the diagnosis of familial Mediterranean fever (FMF). METHODS: Pediatric patients with FMF from the Eurofever registry were used

  5. APPLICATION OF TRAVEL TIME RELIABILITY FOR PERFORMANCE ORIENTED OPERATIONAL PLANNING OF EXPRESSWAYS

    Science.gov (United States)

    Mehran, Babak; Nakamura, Hideki

    Evaluation of impacts of congestion improvement scheme s on travel time reliability is very significant for road authorities since travel time reliability repr esents operational performance of expressway segments. In this paper, a methodology is presented to estimate travel tim e reliability prior to implementation of congestion relief schemes based on travel time variation modeling as a function of demand, capacity, weather conditions and road accident s. For subject expressway segmen ts, traffic conditions are modeled over a whole year considering demand and capacity as random variables. Patterns of demand and capacity are generated for each five minute interval by appl ying Monte-Carlo simulation technique, and accidents are randomly generated based on a model that links acci dent rate to traffic conditions. A whole year analysis is performed by comparing de mand and available capacity for each scenario and queue length is estimated through shockwave analysis for each time in terval. Travel times are estimated from refined speed-flow relationships developed for intercity expressways and buffer time index is estimated consequently as a measure of travel time reliability. For validation, estimated reliability indices are compared with measured values from empirical data, and it is shown that the proposed method is suitable for operational evaluation and planning purposes.

  6. Reliability issues and solutions for coding social communication performance in classroom settings.

    Science.gov (United States)

    Olswang, Lesley B; Svensson, Liselotte; Coggins, Truman E; Beilinson, Jill S; Donaldson, Amy L

    2006-10-01

    To explore the utility of time-interval analysis for documenting the reliability of coding social communication performance of children in classroom settings. Of particular interest was finding a method for determining whether independent observers could reliably judge both occurrence and duration of ongoing behavioral dimensions for describing social communication performance. Four coders participated in this study. They observed and independently coded 6 social communication behavioral dimensions using handheld computers. The dimensions were mutually exclusive and accounted for all verbal and nonverbal productions during a specified time frame. The technology allowed for coding frequency and duration for each entered code. Data were collected from 20 different 2-min video segments of children in kindergarten through 3rd-grade classrooms. Data were analyzed for interobserver and intraobserver agreements using time-interval sorting and Cohen's kappa. Further, interval size and total observation length were manipulated to determine their influence on reliability. The data revealed interval sorting and kappa to be a suitable method for examining reliability of occurrence and duration of ongoing social communication behavioral dimensions. Nearly all comparisons yielded medium to large kappa values; interval size and length of observation minimally affected results. Implications The analysis procedure described in this research solves a challenge in reliability: comparing coding by independent observers of both occurrence and duration of behaviors. Results indicate the utility of a new coding taxonomy and technology for application in online observations of social communication in a classroom setting.

  7. Advanced control rooms and crew performance issues: Implications for human reliability

    International Nuclear Information System (INIS)

    O'Hara, J.M.; Hall, R.E.

    1991-01-01

    Recent trends in advanced control room (ACR) design are considered with respect to their impact on human performance. It is concluded that potentially negative influences exist, however, a variety of factors make it difficult to model, analyze, and quantify these effects for human reliability analyses (HRAs)

  8. Methodology for performing RF reliability experiments on a generic test structure

    NARCIS (Netherlands)

    Sasse, G.T.; de Vries, Rein J.; Schmitz, Jurriaan

    2007-01-01

    This paper discusses a new technique developed for generating well defined RF large voltage swing signals for on wafer experiments. This technique can be employed for performing a broad range of different RF reliability experiments on one generic test structure. The frequency dependence of a

  9. Influence of test reliability on the screening performance of frequency-doubling perimetry

    NARCIS (Netherlands)

    Heeg, GP; Jansonius, NM

    PURPOSE: To investigate the influence of test reliability on the screening performance of frequency,doubling perimetry (FDT). DESIGN: Cross-sectional study. METHODS: FDT sensitivity and specificity were calculated three times using three different strategies for handling unreliable (that is, > 0

  10. Reliability assessment of serviceability performance of braced retaining walls using a neural network approach

    Science.gov (United States)

    Goh, A. T. C.; Kulhawy, F. H.

    2005-05-01

    In urban environments, one major concern with deep excavations in soft clay is the potentially large ground deformations in and around the excavation. Excessive movements can damage adjacent buildings and utilities. There are many uncertainties associated with the calculation of the ultimate or serviceability performance of a braced excavation system. These include the variabilities of the loadings, geotechnical soil properties, and engineering and geometrical properties of the wall. A risk-based approach to serviceability performance failure is necessary to incorporate systematically the uncertainties associated with the various design parameters. This paper demonstrates the use of an integrated neural network-reliability method to assess the risk of serviceability failure through the calculation of the reliability index. By first performing a series of parametric studies using the finite element method and then approximating the non-linear limit state surface (the boundary separating the safe and failure domains) through a neural network model, the reliability index can be determined with the aid of a spreadsheet. Two illustrative examples are presented to show how the serviceability performance for braced excavation problems can be assessed using the reliability index.

  11. A method to evaluate performance reliability of individual subjects in laboratory research applied to work settings.

    Science.gov (United States)

    1978-10-01

    This report presents a method that may be used to evaluate the reliability of performance of individual subjects, particularly in applied laboratory research. The method is based on analysis of variance of a tasks-by-subjects data matrix, with all sc...

  12. The Effect of Instrument-Specific Rater Training on Interrater Reliability and Counseling Skills Performance Differentiation

    Science.gov (United States)

    Meacham, Paul Douglas, Jr.

    2013-01-01

    The purpose of this study was to explore the effect of instrument-specific rater training on interrater reliability (IRR) and counseling skills performance differentiation. Strong IRR is of primary concern to effective program evaluation (McCullough, Kuhn, Andrews, Valen, Hatch, & Osimo, 2003; Schanche, Nielsen, McCullough, Valen, &…

  13. Performance analysis of irreversible quantum Stirling cryogenic refrigeration cycles and their parametric optimum criteria

    International Nuclear Information System (INIS)

    Lin Bihong; Chen Jincan

    2006-01-01

    The influence of both the quantum degeneracy and the finite-rate heat transfer between the working substance and the heat reservoirs on the optimal performance of an irreversible Stirling cryogenic refrigeration cycle using an ideal Fermi or Bose gas as the working substance is investigated, based on the theory of statistical mechanics and thermodynamic properties of ideal quantum gases. The inherent regeneration losses of the cycle are analysed. Expressions for several important performance parameters such as the coefficient of performance, cooling rate and power input are derived. By using numerical solutions, the cooling rate of the cycle is optimized for a given power input. The maximum cooling rate and the corresponding parameters are calculated numerically. The optimal regions of the coefficient of performance and power input are determined. In particular, the optimal performance of the cycle in the strong and weak gas degeneracy cases and the high temperature limit are discussed in detail. The analytic expressions of some optimized parameters are derived. Some optimum criteria are given. The distinctions and connections between the Stirling refrigeration cycles working with the ideal quantum and classical gases are revealed

  14. Assessment of Equipment Capability to Perform Reliably under Severe Accident Conditions

    International Nuclear Information System (INIS)

    2017-07-01

    The experience from the last 40 years has shown that severe accidents can subject electrical and instrumentation and control (I&C) equipment to environmental conditions exceeding the equipment’s original design basis assumptions. Severe accident conditions can then cause rapid degradation or damage to various degrees up to complete failure of such equipment. This publication provides the technical basis to consider when assessing the capability of electrical and I&C equipment to perform reliably during a severe accident. It provides examples of calculation tools to determine the environmental parameters as well as examples and methods that Member States can apply to assess equipment reliability.

  15. Feasibility and Inter-Rater Reliability of Physical Performance Measures in Acutely Admitted Older Medical Patients

    DEFF Research Database (Denmark)

    Bodilsen, Ann Christine; Juul-Larsen, Helle Gybel; Petersen, Janne

    2015-01-01

    OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter-rater reliabi......OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter......-rater reliability of four simple measures of physical performance in acutely admitted older medical patients. DESIGN: During the first 24 hours of hospitalization, the following were assessed twice by different raters in 52 (≥ 65 years) patients admitted for acute medical illness: isometric hand grip strength, 4......, and 30-s chair stand were 8%, 7%, and 18%, and the SRD95% values were 22%, 17%, and 49%. CONCLUSION: In acutely admitted older medical patients, grip strength, gait speed, and the Cumulated Ambulation Score measurements were feasible and showed high inter-rater reliability when administered by different...

  16. Evidence of Reliability and Validity for a Children’s Auditory Continuous Performance Test

    Directory of Open Access Journals (Sweden)

    Michael J. Lasee

    2013-11-01

    Full Text Available Continuous Performance Tests (CPTs are commonly utilized clinical measures of attention and response inhibition. While there have been many studies of CPTs that utilize a visual format, there is considerably less research employing auditory CPTs. The current study provides initial reliability and validity evidence for the Auditory Vigilance Screening Measure (AVSM, a newly developed CPT. Participants included 105 five- to nine-year-old children selected from two rural Midwestern school districts. Reliability data for the AVSM was collected through retesting of 42 participants. Validity was evaluated through correlation of AVSM scales with subscales from the ADHD Rating Scale–IV. Test–retest reliability coefficients ranged from .62 to .74 for AVSM subscales. A significant (r = .31 correlation was obtained between the AVSM Impulsivity Scale and teacher ratings of inattention. Limitations and implications for future study are discussed.

  17. Assessing the influence of reactor system design criteria on the performance of model colon fermentation units.

    Science.gov (United States)

    Moorthy, Arun S; Eberl, Hermann J

    2014-04-01

    Fermentation reactor systems are a key platform in studying intestinal microflora, specifically with respect to questions surrounding the effects of diet. In this study, we develop computational representations of colon fermentation reactor systems as a way to assess the influence of three design elements (number of reactors, emptying mechanism, and inclusion of microbial immobilization) on three performance measures (total biomass density, biomass composition, and fibre digestion efficiency) using a fractional-factorial experimental design. It was determined that the choice of emptying mechanism showed no effect on any of the performance measures. Additionally, it was determined that none of the design criteria had any measurable effect on reactor performance with respect to biomass composition. It is recommended that model fermentation systems used in the experimenting of dietary effects on intestinal biomass composition be streamlined to only include necessary system design complexities, as the measured performance is not benefited by the addition of microbial immobilization mechanisms or semi-continuous emptying scheme. Additionally, the added complexities significantly increase computational time during simulation experiments. It was also noted that the same factorial experiment could be directly adapted using in vitro colon fermentation systems. Copyright © 2013 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  18. Proposed waste form performance criteria and testing methods for low-level mixed waste

    International Nuclear Information System (INIS)

    Franz, E.M.; Fuhrmann, M.; Bowerman, B.; Bates, S.; Peters, R.

    1994-08-01

    This document describes proposed waste form performance criteria and testing method that could be used as guidance in judging viability of a waste form as a physico-chemical barrier to releases of radionuclides and RCRA regulated hazardous components. It is assumed that release of contaminants by leaching is the single most important property by which the effectiveness of a waste form is judged. A two-tier regimen is proposed. The first tier includes a leach test required by the Environmental Protection Agency and a leach test designed to determine the net forward leach rate for a variety of materials. The second tier of tests are to determine if a set of stresses (i.e., radiation, freeze-thaw, wet-dry cycling) on the waste form adversely impact its ability to retain contaminants and remain physically intact. It is recommended that the first tier tests be performed first to determine acceptability. Only on passing the given specifications for the leach tests should other tests be performed. In the absence of site-specific performance assessments (PA), two generic modeling exercises are described which were used to calculate proposed acceptable leach rates

  19. Chemical Technology Division Comprehensive Self-Assessment and Upgrade Program (CSAUP). Performance Objectives and Criteria

    International Nuclear Information System (INIS)

    1990-05-01

    The U.S. Department of Energy (DOE) has placed strong emphasis on a new way of doing business patterned on the lessons learned in the nuclear power industry after the accident at Three Mile Island Unit 2. The new way relies on strict adherence to policies and procedures, a greatly expanded training program, and much more rigor and formality in operations. Another key element is more visible oversight by upper management and auditability by DOR Although the Chemical Technology Division (Chem Tech) has functioned in a safe manner since its beginning, the policies and methods of the past are no longer appropriate. Therefore, in accordance with these directives, Chem Tech is improving its operational performance by making a transition to greater formality in the observance of policies and procedures and a more deliberate consideration of the interrelationships between organizations at ORNL. This transition to formality is vitally important because both our staff and our facilities are changing with time. For example, some of the inventors and developers of the processes and facilities in use are now ''passing the torch'' to the next generation of Chem Tech staff. Our faculties have also served us well for many years, but the newest of these are now over 20 years old. All have increasing needs of refurbishment and repair, and some of the older ones need to be replaced. The Comprehensive Self-Assessment and Upgrade Program (CSAUP) has been patterned on a similar activity performed at the High Flux Isotope Reactor. Using the Draft DOE Performance Objectives and Criteria for Technical Safety Appraisals (May 1987) as a starting point, it was determined that 14 functional areas for evaluation listed in the report were suitable for Chem Tech use. An additional 5 functional areas were added for completeness since Chem Tech has a broader set of missions than a reactor facility. The Performance Objectives and Criteria (POC) for each functional area in the DOE report were

  20. Key Performance Indicators Evaluation and Performance Measurement in Dry Port-Seaport System: A Multi Criteria Approach

    Directory of Open Access Journals (Sweden)

    Fatimazahra BENTALEB

    2015-12-01

    Full Text Available Dry port-seaport services are key elements of a multimodal transport. They represent the needed infrastructure for its development. In this case, evaluating and improving their performance is necessary to achieve international competitiveness. The purpose of this paper is to develop a new model of performance measurement for the dry port-seaport system. To this aim, we have consolidated available researches and existing studies in order to identify and develop our proposed model framework. In this paper, a multi-criteria hierarchical model framework using MACBETH for dry port-seaport system has been developed. This framework can be used by managers at different levels of the system. The proposed model has been developed by exploring measurement gaps in multimodal transport field and by discovering prospective options from this area. The results and the methodology are practical. We obtain the global performance level of our involved system using our methodology, which can help managers in taken decisions and increase global performance of this system.

  1. Primary display latency criteria based on flying qualities and performance data

    Science.gov (United States)

    Funk, John D., Jr.; Beck, Corin P.; Johns, John B.

    1993-01-01

    With a pilots' increasing use of visual cue augmentation, much requiring extensive pre-processing, there is a need to establish criteria for new avionics/display design. The timeliness and synchronization of the augmented cues is vital to ensure the performance quality required for precision mission task elements (MTEs) where augmented cues are the primary source of information to the pilot. Processing delays incurred while transforming sensor-supplied flight information into visual cues are unavoidable. Relationships between maximum control system delays and associated flying qualities levels are documented in MIL-F-83300 and MIL-F-8785. While cues representing aircraft status may be just as vital to the pilot as prompt control response for operations in instrument meteorological conditions, presently, there are no specification requirements on avionics system latency. To produce data relating avionics system latency to degradations in flying qualities, the Navy conducted two simulation investigations. During the investigations, flying qualities and performance data were recorded as simulated avionics system latency was varied. Correlated results of the investigation indicates that there is a detrimental impact of latency on flying qualities. Analysis of these results and consideration of key factors influencing their application indicate that: (1) Task performance degrades and pilot workload increases as latency is increased. Inconsistency in task performance increases as latency increases. (2) Latency reduces the probability of achieving Level 1 handling qualities with avionics system latency as low as 70 ms. (3) The data suggest that the achievement of desired performance will be ensured only at display latency values below 120 ms. (4) These data also suggest that avoidance of inadequate performance will be ensured only at display latency values below 150 ms.

  2. Different Approaches for Ensuring Performance/Reliability of Plastic Encapsulated Microcircuits (PEMs) in Space Applications

    Science.gov (United States)

    Gerke, R. David; Sandor, Mike; Agarwal, Shri; Moor, Andrew F.; Cooper, Kim A.

    2000-01-01

    Engineers within the commercial and aerospace industries are using trade-off and risk analysis to aid in reducing spacecraft system cost while increasing performance and maintaining high reliability. In many cases, Commercial Off-The-Shelf (COTS) components, which include Plastic Encapsulated Microcircuits (PEMs), are candidate packaging technologies for spacecrafts due to their lower cost, lower weight and enhanced functionality. Establishing and implementing a parts program that effectively and reliably makes use of these potentially less reliable, but state-of-the-art devices, has become a significant portion of the job for the parts engineer. Assembling a reliable high performance electronic system, which includes COTS components, requires that the end user assume a risk. To minimize the risk involved, companies have developed methodologies by which they use accelerated stress testing to assess the product and reduce the risk involved to the total system. Currently, there are no industry standard procedures for accomplishing this risk mitigation. This paper will present the approaches for reducing the risk of using PEMs devices in space flight systems as developed by two independent Laboratories. The JPL procedure involves primarily a tailored screening with accelerated stress philosophy while the APL procedure is primarily, a lot qualification procedure. Both Laboratories successfully have reduced the risk of using the particular devices for their respective systems and mission requirements.

  3. The prone bridge test: Performance, validity, and reliability among older and younger adults.

    Science.gov (United States)

    Bohannon, Richard W; Steffl, Michal; Glenney, Susan S; Green, Michelle; Cashwell, Leah; Prajerova, Kveta; Bunn, Jennifer

    2018-04-01

    The prone bridge maneuver, or plank, has been viewed as a potential alternative to curl-ups for assessing trunk muscle performance. The purpose of this study was to assess prone bridge test performance, validity, and reliability among younger and older adults. Sixty younger (20-35 years old) and 60 older (60-79 years old) participants completed this study. Groups were evenly divided by sex. Participants completed surveys regarding physical activity and abdominal exercise participation. Height, weight, body mass index (BMI), and waist circumference were measured. On two occasions, 5-9 days apart, participants held a prone bridge until volitional exhaustion or until repeated technique failure. Validity was examined using data from the first session: convergent validity by calculating correlations between survey responses, anthropometrics, and prone bridge time, known groups validity by using an ANOVA comparing bridge times of younger and older adults and of men and women. Test-retest reliability was examined by using a paired t-test to compare prone bridge times for Session1 and Session 2. Furthermore, an intraclass correlation coefficient (ICC) was used to characterize relative reliability and minimal detectable change (MDC 95% ) was used to describe absolute reliability. The mean prone bridge time was 145.3 ± 71.5 s, and was positively correlated with physical activity participation (p ≤ 0.001) and negatively correlated with BMI and waist circumference (p ≤ 0.003). Younger participants had significantly longer plank times than older participants (p = 0.003). The ICC between testing sessions was 0.915. The prone bridge test is a valid and reliable measure for evaluating abdominal performance in both younger and older adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. RELIABILITY OF ANKLE-FOOT MORPHOLOGY, MOBILITY, STRENGTH, AND MOTOR PERFORMANCE MEASURES.

    Science.gov (United States)

    Fraser, John J; Koldenhoven, Rachel M; Saliba, Susan A; Hertel, Jay

    2017-12-01

    Assessment of foot posture, morphology, intersegmental mobility, strength and motor control of the ankle-foot complex are commonly used clinically, but measurement properties of many assessments are unclear. To determine test-retest and inter-rater reliability, standard error of measurement, and minimal detectable change of morphology, joint excursion and play, strength, and motor control of the ankle-foot complex. Reliability study. 24 healthy, recreationally-active young adults without history of ankle-foot injury were assessed by two clinicians on two occasions, three to ten days apart. Measurement properties were assessed for foot morphology (foot posture index, total and truncated length, width, arch height), joint excursion (weight-bearing dorsiflexion, rearfoot and hallux goniometry, forefoot inclinometry, 1 st metatarsal displacement) and joint play, strength (handheld dynamometry), and motor control rating during intrinsic foot muscle (IFM) exercises. Clinician order was randomized using a Latin Square. The clinicians performed independent examinations and did not confer on the findings for the duration of the study. Test-retest and inter-tester reliability and agreement was assessed using intraclass correlation coefficients (ICC 2,k ) and weighted kappa ( K w ). Test-retest reliability ICC were as follows: morphology: .80-1.00, joint excursion: .58-.97, joint play: -.67-.84, strength: .67-.92, IFM motor rating: K W -.01-.71. Inter-rater reliability ICC were as follows: morphology: .81-1.00, joint excursion: .32-.97, joint play: -1.06-1.00, strength: .53-.90, and IFM motor rating: K w .02-.56. Measures of ankle-foot posture, morphology, joint excursion, and strength demonstrated fair to excellent test-retest and inter-rater reliability. Test-retest reliability for rating of perceived difficulty and motor performance was good to excellent for short-foot, toe-spread-out, and hallux exercises and poor to fair for lesser toe extension. Joint play measures had

  5. Performance Evaluation of Five Different Disseminated Intravascular Coagulation (DIC) Diagnostic Criteria for Predicting Mortality in Patients with Complicated Sepsis.

    Science.gov (United States)

    Ha, Sang Ook; Park, Sang Hyuk; Hong, Sang Bum; Jang, Seongsoo

    2016-11-01

    Disseminated intravascular coagulation (DIC) is a major complication in sepsis patients. We compared the performance of five DIC diagnostic criteria, focusing on the prediction of mortality. One hundred patients with severe sepsis or septic shock admitted to intensive care unit (ICU) were enrolled. Routine DIC laboratory tests were performed over the first 4 days after admission. The overall ICU and 28-day mortality in DIC patients diagnosed from five criteria (International Society on Thrombosis and Haemostasis [ISTH], the Japanese Association for Acute Medicine [JAAM], the revised JAAM [R-JAAM], the Japanese Ministry of Health and Welfare [JMHW] and the Korean Society on Thrombosis and Hemostasis [KSTH]) were compared. Both KSTH and JMHW criteria showed superior performance than ISTH, JAAM and R-JAAM criteria in the prediction of overall ICU mortality in DIC patients (odds ratio 3.828 and 5.181, P = 0.018 and 0.006, 95% confidence interval 1.256-11.667 and 1.622-16.554, respectively) when applied at day 1 after admission, and survival analysis demonstrated significant prognostic impact of KSTH and JMHW criteria on the prediction of 28-day mortality (P = 0.007 and 0.049, respectively) when applied at day 1 after admission. In conclusion, both KSTH and JMHW criteria would be more useful than other three criteria in predicting prognosis in DIC patients with severe sepsis or septic shock.

  6. Multi-criteria group decision making for evaluating the performance of e-waste recycling programs under uncertainty.

    Science.gov (United States)

    Wibowo, Santoso; Deng, Hepu

    2015-06-01

    This paper presents a multi-criteria group decision making approach for effectively evaluating the performance of e-waste recycling programs under uncertainty in an organization. Intuitionistic fuzzy numbers are used for adequately representing the subjective and imprecise assessments of the decision makers in evaluating the relative importance of evaluation criteria and the performance of individual e-waste recycling programs with respect to individual criteria in a given situation. An interactive fuzzy multi-criteria decision making algorithm is developed for facilitating consensus building in a group decision making environment to ensure that all the interest of individual decision makers have been appropriately considered in evaluating alternative e-waste recycling programs with respect to their corporate sustainability performance. The developed algorithm is then incorporated into a multi-criteria decision support system for making the overall performance evaluation process effectively and simple to use. Such a multi-criteria decision making system adequately provides organizations with a proactive mechanism for incorporating the concept of corporate sustainability into their regular planning decisions and business practices. An example is presented for demonstrating the applicability of the proposed approach in evaluating the performance of e-waste recycling programs in organizations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. An evaluation of the predictive validity and inter-rater reliability of clinical diagnostic criteria for senile dementia of Lewy body type.

    Science.gov (United States)

    McKeith, I G; Fairbairn, A F; Bothwell, R A; Moore, P B; Ferrier, I N; Thompson, P; Perry, R H

    1994-05-01

    Several recent autopsy studies suggest that senile dementia of Lewy body type (SDLT) may be the second most common neuropathologic cause of dementia in the elderly, accounting for 7 to 30% of all cases. Operational criteria for the antemortem clinical diagnosis of SDLT have already been proposed by our group. The performance of these is now examined by randomizing the case notes from a new series of SDLT, Alzheimer, and multi-infarct dementia patients for psychiatric assessment by four raters of varying clinical experience and blind to pathologic diagnosis. Using the SDLT criteria, the two most experienced raters agreed in 94% of cases (kappa = 0.87), with the least experienced rater agreeing in 78% (kappa = 0.50). Diagnostic specificity for SDLT was uniformly high (90.0 to 97.0%), with a mean sensitivity of detection of 74%, and was greater by the experienced (90.0%) than the least experienced (55%) clinician. The antemortem identification of SDLT patients can therefore be achieved with a high degree of diagnostic specificity using such operationalized criteria, although there remains a minority of patients who present with either "typical" Alzheimer-type symptoms or with paranoid or delusional symptoms in the absence of substantial cognitive impairment. Sensitivity to neuroleptics may be a useful diagnostic pointer in these patients.

  8. A decision support system for mission-based ship routing considering multiple performance criteria

    International Nuclear Information System (INIS)

    Dong, You; Frangopol, Dan M.; Sabatino, Samantha

    2016-01-01

    It is crucial to evaluate the risk associated with marine vessels subjected to inclement weather and sea conditions when developing a decision support system for ship routing. The generalized decision making framework developed in this paper performs a variety of tasks, including, but not limited to quantifying the flexural and fatigue performance of ship structures and employing multi-attribute utility theory to evaluate ship mission performance. A structural reliability approach is utilized to compute the probability of failure considering the uncertainties in structural capacity and load effects; specifically, effects of flexural and fatigue damage are investigated. The expected repair cost, cumulative fatigue damage, total travel time, and carbon dioxide emissions associated with ship routing are considered as consequences within the risk assessment procedure adopted in this paper. Additionally, the decision maker’s risk attitude is integrated into the presented approach by employing utility theory. The presented methodology can assist decision makers in making informed decisions concerning ship routing. In order to illustrate its capabilities the approach is applied to the Joint High-speed Sealift Ship. - Highlights: • Multi-attribute utility theory is proposed for the ship routing decision making. • Spectral-based fatigue damage and repair loss are computed. • Travel time and CO_2 emissions are incorporated within the decision making process. • The attitude of the decision maker has significant effects on the utility value.

  9. Impact of nuclear fuel performance and reliability in a deregulated electricity market

    International Nuclear Information System (INIS)

    Barnoski, M.; Kaiser, B.

    1997-01-01

    US nuclear plants are now placing a great deal of importance on fuel performance and reliability because of their direct effect on a plant's capacity factor, availability, operating flexibility, outage duration, and worker exposure. This is reflected by utilities making fuel reliability a principal vendor evaluation criterion and making fuel performance an important bonus/penalty provision. Defect-free fuel, combined with ever improving design features, makes it possible for plants to operate at higher outputs while reducing operating and maintenance costs. Higher electrical output at lower cost is essential for US nuclear plants to meet the expected competition in a deregulated market. Through continued investment in manufacturing improvements and a vigilant, systematic design process, ABB's nuclear fuel has contributed to helping its nuclear utility customers reduce their cost of doing business. (author) 1 fig., 1 tab

  10. Performance and reliability of the Y-Balance TestTM in high school athletes.

    Science.gov (United States)

    Smith, Laura J; Creps, James R; Bean, Ryan; Rodda, Becky; Alsalaheen, Bara

    2017-11-07

    Lower extremity injuries account for 32.9% of the overall injuries in high school athletes. Previous research has suggested that asymmetry greater than 4cm using the Y-Balance TestTM Lower Quarter (YBT-LQ) in the anterior direction is predictive of non- contact injuries in adults and collegiate athletes. The prevalence of asymmetries or abnormal YBT-LQ performance is not well documented for adolescents. The primary purposes of this study are: 1) to characterize the prevalence of YBT-LQ asymmetries and performance in a cross-sectional sample of adolescents, 2) to examine possible differences in performance on the YBT-LQ between male and female adolescents, and 3) to describe the test-retest reliability of the YBT-LQ in a subsample of adolescents. Observational cross-sectional study. High-school athletes completed the YBT-LQ as main outcome measure. 51 male, 59 female high-school athletes participated in this study. Asymmetries greater than 4cm in the posteromedial (PM) reach direction were most prevalent for male (54.9%) and female (50.8%) participants. Females presented with slightly higher composite scores. Good reliability (ICC = 0.89) was found for the anterior (ANT) direction, and moderate reliability with 0.76 for posterolateral (PL) and 0.63 for PM directions. The MDC95 for the ANT direction was 6% and 12% for both the PL and PM directions. The YBT-LQ performance can be beneficial in assessing recovery in an injured extremity compared to the other limb. However, due to the large MDC95, noted in the PM and PL directions, the differences between sequential testing cannot be attributed to true change in balance unless they exceed the MDC95. In this study, 79% of the athletes presented with at least one asymmetry in YBT-LQ reach distances. Moderate reliability in the PL and PM directions warrants reexamination of the definition of asymmetry in these directions.

  11. Reliability of performance velocity for jump squats under feedback and nonfeedback conditions.

    Science.gov (United States)

    Randell, Aaron D; Cronin, John B; Keogh, Justin Wl; Gill, Nicholas D; Pedersen, Murray C

    2011-12-01

    Randell, AD, Cronin, JB, Keogh, JWL, Gill, ND, and Pedersen, MC. Reliability of performance velocity for jump squats under feedback and nonfeedback conditions. J Strength Cond Res 25(12): 3514-3518, 2011-Advancements in the monitoring of kinematic and kinetic variables during resistance training have resulted in the ability to continuously monitor performance and provide feedback during training. If equipment and software can provide reliable instantaneous feedback related to the variable of interest during training, it is thought that this may result in goal-oriented movement tasks that increase the likelihood of transference to on-field performance or at the very least improve the mechanical variable of interest. The purpose of this study was to determine the reliability of performance velocity for jump squats under feedback and nonfeedback conditions over 3 consecutive training sessions. Twenty subjects were randomly allocated to a feedback or nonfeedback group, and each group performed a total of 3 "jump squat" training sessions with the velocity of each repetition measured using a linear position transducer. There was less change in mean velocities between sessions 1-2 and sessions 2-3 (0.07 and 0.02 vs. 0.13 and -0.04 m·s), less random variation (TE = 0.06 and 0.06 vs. 0.10 and 0.07 m·s) and greater consistency (intraclass correlation coefficient = 0.83 and 0.87 vs. 0.53 and 0.74) between sessions for the feedback condition as compared to the nonfeedback condition. It was concluded that there is approximately a 50-50 probability that the provision of feedback was beneficial to the performance in the squat jump over multiple sessions. It is suggested that this has the potential for increasing transference to on-field performance or at the very least improving the mechanical variable of interest.

  12. Criteria for Performing Cranial Computed Tomography for Chinese Patients With Mild Traumatic Brain Injury: Canadian Computed Tomography Head Rule or New Orleans Criteria?

    Science.gov (United States)

    Yang, Xiao-Feng; Meng, Yuan-Yuan; Wen, Liang; Wang, Hao

    2017-09-01

    Computed tomography (CT) provides the primary diagnostic evidence for traumatic brain injury (TBI), but few positive traumatic findings are discovered in patients with mild TBI. In China, there are no existing criteria for selecting patients with mild TBI to undergo CT, and almost all of these patients undergo cranial CT in the emergency department. This retrospective study was performed to evaluate the necessity of cranial CT among patients with mild TBI, as well as the feasibility of 2 popular criteria (Canadian CT head rule [CCHR] and New Orleans Criteria [NOC]) in China. Patients with mild TBI who underwent cranial CT within 24 hours of the trauma were included in our institute. Two neurosurgeons reviewed the CT images independently to identify positive CT findings. The sensitivity and specificity of CCHR and NOC for positive CT findings related to TBI were analyzed. Finally, this study included 625 patients. Positive CT findings related to TBI were discovered in 13.12% (82/625) of these patients on cranial CT, and 6.88% (43/625) of them were admitted to the hospital for further management. Ultimately, 11 patients (1.76%, 11/625) underwent neurosurgery. In this study, the sensitivities of both the CCHR and NOC were 100%, but the specificity of CCHR was 43.36% and that of NOC was 33.12%. Based on our study, both CCHR and NOC have high sensitivity for the detection of positive CT findings related to head trauma in patients with mild TBI.

  13. NWTS program criteria for mined geologic disposal of nuclear waste: functional requirements and performance criteria for waste packages for solidified high-level waste and spent fuel

    International Nuclear Information System (INIS)

    1982-07-01

    The Department of Energy (DOE) has primary federal responsibility for the development and implementation of safe and environmentally acceptable nuclear waste disposal methods. Currently, the principal emphasis in the program is on emplacement of nuclear wastes in mined geologic repositories well beneath the earth's surface. A brief description of the mined geologic disposal system is provided. The National Waste Terminal Storage (NWTS) program was established under DOE's predecessor, the Energy Research and Development Administration, to provide facilities for the mined geologic disposal of radioactive wastes. The NWTS program includes both the development and the implementation of the technology necessary for designing, constructing, licensing, and operating repositories. The program does not include the management of processing radioactive wastes or of transporting the wastes to repositories. The NWTS-33 series, of which this document is a part, provides guidance for the NWTS program in the development and implementation of licensed mined geologic disposal systems for solidified high-level and transuranic (TRU) wastes. This document presents the functional requirements and performance criteria for waste packages for solidified high-level waste and spent fuel. A separate document to be developed, NWTS-33(4b), will present the requirements and criteria for waste packages for TRU wastes. The hierarchy and application of these requirements and criteria are discussed in Section 2.2

  14. The performance shaping factors influence analysis on the human reliability for NPP operation

    International Nuclear Information System (INIS)

    Farcasiu, M.; Nitoi, M.; Apostol, M.; Florescu, G.

    2008-01-01

    The Human Reliability Analysis (HRA) is an important step in Probabilistic Safety Assessment (PSA) studies and offers an advisability for concrete improvement of the man - machine - organization interfaces, reliability and safety. The goals of this analysis are to obtain sufficient details in order to understand and document all-important factors that affect human performance. The purpose of this paper is to estimate the human errors probabilities in view of the negative or positive effect of the human performance shaping factors (PSFs) for the mitigation of the initiating events which could occur in Nuclear Power Plant (NPP). Using THERP and SPAR-H methods, an analysis model of PSFs influence on the human reliability is performed. This model is applied to more important activities, that are necessary to mitigate 'one steam generator tube failure' event at Cernavoda NPP. The results are joint human error probabilities (JHEP) values estimated for the following situations: without regarding to PSFs influence; with PSFs in specific conditions; with PSFs which could have only positive influence and with PSFs which could have only negative influence. In addition, PSFs with negative influence were identified and using the DOE method, the necessary activities for changing negative influence were assigned. (authors)

  15. Reliability assessment of stress concentration performance state for a perforated composite plate under traction

    Directory of Open Access Journals (Sweden)

    Jabbouri A.

    2012-07-01

    Full Text Available Considering a perforated sandwich plate made from two elastic homogenous and isotropic layers, and having a square hole, reliability assessment of stress concentration limit state for which the stress should not exceed a given threshold is performed in this work. Assuming that the plate dimensions and the applied loading are deterministic, focus is done on the square hole centre position and edge length considered to be random variables. The means and the standard deviations of these variables are assumed to be known, but no information is so far available about their densities of probabilities. To assess reliability of the performance state, reliability analysis known methods are applied to a response surface representation of the stress concentration factor of the perforated plate which is obtained through quadratic polynomial regression of finite element results. A parametric study is performed regarding the influence of the distributions of probabilities chosen to model the hole dimensions uncertainties. It is shown that the probability of failure depends largely on the selected densities of probabilities.

  16. ASYMMETRIC PRICE TRANSMISSION MODELING: THE IMPORTANCE OF MODEL COMPLEXITY AND THE PERFORMANCE OF THE SELECTION CRITERIA

    Directory of Open Access Journals (Sweden)

    Henry de-Graft Acquah

    2013-01-01

    Full Text Available Information Criteria provides an attractive basis for selecting the best model from a set of competing asymmetric price transmission models or theories. However, little is understood about the sensitivity of the model selection methods to model complexity. This study therefore fits competing asymmetric price transmission models that differ in complexity to simulated data and evaluates the ability of the model selection methods to recover the true model. The results of Monte Carlo experimentation suggest that in general BIC, CAIC and DIC were superior to AIC when the true data generating process was the standard error correction model, whereas AIC was more successful when the true model was the complex error correction model. It is also shown that the model selection methods performed better in large samples for a complex asymmetric data generating process than with a standard asymmetric data generating process. Except for complex models, AIC's performance did not make substantial gains in recovery rates as sample size increased. The research findings demonstrate the influence of model complexity in asymmetric price transmission model comparison and selection.

  17. Decomposition of the Mean Squared Error and NSE Performance Criteria: Implications for Improving Hydrological Modelling

    Science.gov (United States)

    Gupta, Hoshin V.; Kling, Harald; Yilmaz, Koray K.; Martinez-Baquero, Guillermo F.

    2009-01-01

    The mean squared error (MSE) and the related normalization, the Nash-Sutcliffe efficiency (NSE), are the two criteria most widely used for calibration and evaluation of hydrological models with observed data. Here, we present a diagnostically interesting decomposition of NSE (and hence MSE), which facilitates analysis of the relative importance of its different components in the context of hydrological modelling, and show how model calibration problems can arise due to interactions among these components. The analysis is illustrated by calibrating a simple conceptual precipitation-runoff model to daily data for a number of Austrian basins having a broad range of hydro-meteorological characteristics. Evaluation of the results clearly demonstrates the problems that can be associated with any calibration based on the NSE (or MSE) criterion. While we propose and test an alternative criterion that can help to reduce model calibration problems, the primary purpose of this study is not to present an improved measure of model performance. Instead, we seek to show that there are systematic problems inherent with any optimization based on formulations related to the MSE. The analysis and results have implications to the manner in which we calibrate and evaluate environmental models; we discuss these and suggest possible ways forward that may move us towards an improved and diagnostically meaningful approach to model performance evaluation and identification.

  18. Extrapolating power-ramp performance criteria for current and advanced CANDU fuels

    Energy Technology Data Exchange (ETDEWEB)

    Tayal, M.; Chassie, G.G

    2000-06-01

    To improve the precision and accuracy of power-ramp performance criteria for high-burnup fuel, we have examined in-reactor fuel performance data as well as out-reactor test data. The data are consistent with some of the concepts used in the current formulations for defining fuel failure thresholds, such as size of power-ramp and extent of burnup. Our review indicates that there is a need to modify some other aspects of the current formulations; therefore, a modified formulation is presented in this paper. The improvements mainly concern corrodent concentration and its relationships with threshold stress for failure. The new formulation is consistent with known and expected trends such as strength of Zircaloy in corrosive environment, timing of the release of fission products to the pellet-to-sheath gap, CANLUB coating, and fuel burnup. Because of the increased precision and accuracy, the new formulation is better able to identify operational regimes that are at risk of power-ramp failures; this predictive ability provides enhanced protection to fuel against power-ramp defects. At die same time, by removing unnecessary conservatisms in other areas, the new formulation permits a greater range of defect-free operational envelope as well as larger operating margins in regions that are, in fact, not prone to power-ramp failures. (author)

  19. ANALISIS PENGUKURAN KINERJA PENGADAAN MENGGUNAKAN METODE SINK’S SEVEN PERFORMANCE CRITERIA (Studi Kasus di Universitas Diponegoro Semarang Tahun 2007

    Directory of Open Access Journals (Sweden)

    Purnawan Adi Wicaksono

    2012-02-01

    Full Text Available Pengukuran kinerja pengadaan di Universitas Diponegoro telah dilakukan dengan melihat segi financial. Pengukuran secara finansial memiliki kelemahan yaitu tidak dapat menjelaskan apakah dengan penyerapan anggaran yang semakin besar maka akan semakin baik efisiensi dan kinerjanya. Ukuran kinerja lain yang penting seperti ketepatan waktu pengiriman barang, kecocokan spesifikasi dan jumlah barang, hingga tujuan dan keinginan pengguna apakah sesuai atau tidak, belum terukur dengan jelas. Pengukuran kinerja pengadaan akan dilakukan menggunakan model Sink’s Seven Performance Criteria, yaitu model pengukuran kinerja yang menggambarkan suatu sistem manajemen sebagai suatu mekanisme untuk membangun siklus perbaikan yang lebih efektif. Hasil perancangan pengukuran kinerja terdiri dari 6 kriteria dengan urutan prioritas sebagai berikut: kriteria Kualitas (31%, kriteria Efisiensi (17.2%, kriteria Efektivitas (17.2%, kriteria Kualitas Kehidupan Kerja (13.8%, kriteria Budgetabilitas (11.6%, dan kriteria Inovasi (9.2%. Dari keenam kriteria kinerja tersebut, diperoleh rancangan akhir 32 KPI yang berisi: 17 KPI Kuantitatif dan 15 KPI Kualitatif. Berdasarkan hasil pengukuran kinerja dengan Objective Matrix dan Traffic Light System, menunjukkan bahwa kinerja pengadaan tahun 2007 adalah sebesar 4.564 yang berada dalam kategori warna kuning yang berarti pencapaian kinerjanya ini sudah cukup baik meskipun nilainya mendekati kategori buruk, sehingga masih perlu ditingkatkan lagi. Dari hasil analisis Importance – Performance Matrix, diperoleh indikator-indikator yang berada dalam zona penting tetapi ternyata kinerjanya masih rendah. Indikator tersebut adalah Efisiensi waktu, Efisiensi jumlah personil, Pemborosan waktu, Pemborosan personil, Jumlah lelang gagal/lelang ulang, Jumlah keluhan pengguna, Jumlah penyedia ingkar kontrak, dan Inovasi proses. Oleh karena itu rekomendasi diutamakan untuk indikator-indikator di atas. Kata Kunci: Pengukuran kinerja Pengadaan

  20. Development of a reliable and clinically useful Italian version of the Axis II for the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD

    Directory of Open Access Journals (Sweden)

    Ludovica Antonella Macrì

    2008-06-01

    Full Text Available

    Background: Multiple-language versions of the same psychometric instrument are increasingly needed, but simply translating an English version word-to-word into another language is not adequate to account for linguistic and cultural differences. Our aim was to alidate an Italian version of the Axis II of the Research Diagnostic Criteria for temporomandibular disorders (RDC/TMD and to test its reproducibility in order to use this important diagnostic instrument in Italian patients.

    Methods: The original English-language version was translated and culturally adapted for Italian-speaking people, back-translated to English and then tested on 68 subjects: 34 TMD patients and 34 healthy subjects. Internal consistency was assessed by calculating the Cronbach coefficient alpha for the entire scale in the two samples. The reproducibility of the domains was assessed with the use of the Spearman-Brown test-retest reliability test, Wilcoxon matched pair test, Sign test and 2x2table Chi Square test according to the data types. Correlation of the initial and test-retest scores of the Axis II was measured with the Spearman rank correlation coefficient as an additional measure of reproducibility.

    Results: The Italian version of Axis II has a good eproducibility; the internal consistency (measured with he Cronbach coefficient alpha of the overall final questionnaire was excellent: 0.95.

    Conclusions: The Axis II Italian version appeared reliable and it could be useful to assess TMD patients and to standardize the data acquisition in this relevant and common disease.

  1. Diagnostic Performance of Three Phase Bone Scan for Complex Regional Pain Syndrome Type 1 with Optimally Modified Image Criteria

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyun Woo; Paeng, Jin Chul; Nahm, Francins Sahngun; Kim, Seog Gyun; Zehra, Tanzeel; Oh, So Won; Lee, Hyo Sang; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    2011-12-15

    Although the three phase bone scan (TBPS) is one of the widely used imaging studies for diagnosing complex regional pain syndrome type 1 (CRPS 1), there is some controversy regarding the TPBS image criteria for CRPS 1. In this study, we modified the image criteria using image pattern and quantitative analysis in the patients diagnosed using the most recent consensus clinical diagnostic criteria. The study included 140 patients with suspected CRPS 1 (CRPS 1, n=79; non CRPS, n=61; mean age 39{+-}15 years) who underwent TPBS. The clinical diagnostic criteria for CRPS 1 revised by the Budapest consensus group were used for confirmative diagnosis. Patients were classified according to flow/pool and delayed uptake (DU) image patterns, and the time interval between the initiating event and TPBS (TI{sup eventscan)}. Quantitative analysis for lesion to contralateral ratio (LCR) was performed. Modified TPBS image criteria were created and evaluated for optimal diagnostic performance. Both increased and decreased periarticular DU were significant image findings for CRPS 1 (CRPS 1 positive rate=73% in the increased DU group, 75% in the decreased DU group). The TI{sup eventscand}id not differ significantly between the different image pattern groups. Quantitative analysis revealed an LCR of 1.43 was the optimal cutoff value for CRPS 1 and diagnostic performance was significantly improved in the increased DU group (area under the curve=0.732). Given the modified image criteria, the sensitivity and specificity of TPBS for diagnosing CRPS 1 were 80% and 72%, respectively. Optimally modified TPBS image criteria for CRPS 1 were suggested using image pattern and quantitative analysis. With the criteria, TPBS is an effective imaging study for CRPS 1 even with the most recent consensus clinical diagnostic criteria.

  2. Diagnostic Performance of Three Phase Bone Scan for Complex Regional Pain Syndrome Type 1 with Optimally Modified Image Criteria

    International Nuclear Information System (INIS)

    Kwon, Hyun Woo; Paeng, Jin Chul; Nahm, Francins Sahngun; Kim, Seog Gyun; Zehra, Tanzeel; Oh, So Won; Lee, Hyo Sang; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo

    2011-01-01

    Although the three phase bone scan (TBPS) is one of the widely used imaging studies for diagnosing complex regional pain syndrome type 1 (CRPS 1), there is some controversy regarding the TPBS image criteria for CRPS 1. In this study, we modified the image criteria using image pattern and quantitative analysis in the patients diagnosed using the most recent consensus clinical diagnostic criteria. The study included 140 patients with suspected CRPS 1 (CRPS 1, n=79; non CRPS, n=61; mean age 39±15 years) who underwent TPBS. The clinical diagnostic criteria for CRPS 1 revised by the Budapest consensus group were used for confirmative diagnosis. Patients were classified according to flow/pool and delayed uptake (DU) image patterns, and the time interval between the initiating event and TPBS (TI eventscan) . Quantitative analysis for lesion to contralateral ratio (LCR) was performed. Modified TPBS image criteria were created and evaluated for optimal diagnostic performance. Both increased and decreased periarticular DU were significant image findings for CRPS 1 (CRPS 1 positive rate=73% in the increased DU group, 75% in the decreased DU group). The TI eventscand id not differ significantly between the different image pattern groups. Quantitative analysis revealed an LCR of 1.43 was the optimal cutoff value for CRPS 1 and diagnostic performance was significantly improved in the increased DU group (area under the curve=0.732). Given the modified image criteria, the sensitivity and specificity of TPBS for diagnosing CRPS 1 were 80% and 72%, respectively. Optimally modified TPBS image criteria for CRPS 1 were suggested using image pattern and quantitative analysis. With the criteria, TPBS is an effective imaging study for CRPS 1 even with the most recent consensus clinical diagnostic criteria.

  3. Study on Performance Shaping Factors (PSFs) Quantification Method in Human Reliability Analysis (HRA)

    International Nuclear Information System (INIS)

    Kim, Ar Ryum; Jang, Inseok Jang; Seong, Poong Hyun; Park, Jinkyun; Kim, Jong Hyun

    2015-01-01

    The purpose of HRA implementation is 1) to achieve the human factor engineering (HFE) design goal of providing operator interfaces that will minimize personnel errors and 2) to conduct an integrated activity to support probabilistic risk assessment (PRA). For these purposes, various HRA methods have been developed such as technique for human error rate prediction (THERP), simplified plant analysis risk human reliability assessment (SPAR-H), cognitive reliability and error analysis method (CREAM) and so on. In performing HRA, such conditions that influence human performances have been represented via several context factors called performance shaping factors (PSFs). PSFs are aspects of the human's individual characteristics, environment, organization, or task that specifically decrements or improves human performance, thus respectively increasing or decreasing the likelihood of human errors. Most HRA methods evaluate the weightings of PSFs by expert judgment and explicit guidance for evaluating the weighting is not provided. It has been widely known that the performance of the human operator is one of the critical factors to determine the safe operation of NPPs. HRA methods have been developed to identify the possibility and mechanism of human errors. In performing HRA methods, the effect of PSFs which may increase or decrease human error should be investigated. However, the effect of PSFs were estimated by expert judgment so far. Accordingly, in order to estimate the effect of PSFs objectively, the quantitative framework to estimate PSFs by using PSF profiles is introduced in this paper

  4. Performance of intraclass correlation coefficient (ICC) as a reliability index under various distributions in scale reliability studies.

    Science.gov (United States)

    Mehta, Shraddha; Bastero-Caballero, Rowena F; Sun, Yijun; Zhu, Ray; Murphy, Diane K; Hardas, Bhushan; Koch, Gary

    2018-04-29

    Many published scale validation studies determine inter-rater reliability using the intra-class correlation coefficient (ICC). However, the use of this statistic must consider its advantages, limitations, and applicability. This paper evaluates how interaction of subject distribution, sample size, and levels of rater disagreement affects ICC and provides an approach for obtaining relevant ICC estimates under suboptimal conditions. Simulation results suggest that for a fixed number of subjects, ICC from the convex distribution is smaller than ICC for the uniform distribution, which in turn is smaller than ICC for the concave distribution. The variance component estimates also show that the dissimilarity of ICC among distributions is attributed to the study design (ie, distribution of subjects) component of subject variability and not the scale quality component of rater error variability. The dependency of ICC on the distribution of subjects makes it difficult to compare results across reliability studies. Hence, it is proposed that reliability studies should be designed using a uniform distribution of subjects because of the standardization it provides for representing objective disagreement. In the absence of uniform distribution, a sampling method is proposed to reduce the non-uniformity. In addition, as expected, high levels of disagreement result in low ICC, and when the type of distribution is fixed, any increase in the number of subjects beyond a moderately large specification such as n = 80 does not have a major impact on ICC. Copyright © 2018 John Wiley & Sons, Ltd.

  5. Reliability of cortical lesion detection on double inversion recovery MRI applying the MAGNIMS-Criteria in multiple sclerosis patients within a 16-months period.

    Directory of Open Access Journals (Sweden)

    Tobias Djamsched Faizy

    Full Text Available In patients with multiple sclerosis (MS, Double Inversion Recovery (DIR magnetic resonance imaging (MRI can be used to identify cortical lesions (CL. We sought to evaluate the reliability of CL detection on DIR longitudinally at multiple subsequent time-points applying the MAGNIMs scoring criteria for CLs.26 MS patients received a 3T-MRI (Siemens, Skyra with DIR at 12 time-points (TP within a 16 months period. Scans were assessed in random order by two different raters. Both raters separately marked all CLs on each scan and total lesion numbers were obtained for each scan-TP and patient. After a retrospective re-evaluation, the number of consensus CLs (conL was defined as the total number of CLs, which both raters finally agreed on. CLs volumes, relative signal intensities and CLs localizations were determined. Both ratings (conL vs. non-consensus scoring were compared for further analysis.A total number of n = 334 CLs were identified by both raters in 26 MS patients with a first agreement of both raters on 160 out of 334 of the CLs found (κ = 0.48. After the retrospective re-evaluation, consensus agreement increased to 233 out of 334 CL (κ = 0.69. 93.8% of conL were visible in at least 2 consecutive TP. 74.7% of the conL were visible in all 12 consecutive TP. ConL had greater mean lesion volumes and higher mean signal intensities compared to lesions that were only detected by one of the raters (p<0.05. A higher number of CLs in the frontal, parietal, temporal and occipital lobe were identified by both raters than the number of those only identified by one of the raters (p<0.05.After a first assessment, slightly less than a half of the CL were considered as reliably detectable on longitudinal DIR images. A retrospective re-evaluation notably increased the consensus agreement. However, this finding is narrowed, considering the fact that retrospective evaluation steps might not be practicable in clinical routine. Lesions that were not reliably

  6. Reliability and validity of the Performance Recorder 1 for measuring isometric knee flexor and extensor strength.

    Science.gov (United States)

    Neil, Sarah E; Myring, Alec; Peeters, Mon Jef; Pirie, Ian; Jacobs, Rachel; Hunt, Michael A; Garland, S Jayne; Campbell, Kristin L

    2013-11-01

    Muscular strength is a key parameter of rehabilitation programs and a strong predictor of functional capacity. Traditional methods to measure strength, such as manual muscle testing (MMT) and hand-held dynamometry (HHD), are limited by the strength and experience of the tester. The Performance Recorder 1 (PR1) is a strength assessment tool attached to resistance training equipment and may be a time- and cost-effective tool to measure strength in clinical practice that overcomes some limitations of MMT and HHD. However, reliability and validity of the PR1 have not been reported. Test-retest and inter-rater reliability was assessed using the PR1 in healthy adults (n  =  15) during isometric knee flexion and extension. Criterion-related validity was assessed through comparison of values obtained from the PR1 and Biodex® isokinetic dynamometer. Test-retest reliability was excellent for peak knee flexion (intra-class correlation coefficient [ICC] of 0.96, 95% CI: 0.85, 0.99) and knee extension (ICC  =  0.96, 95% CI: 0.87, 0.99). Inter-rater reliability was also excellent for peak knee flexion (ICC  =  0.95, 95% CI: 0.85, 0.99) and peak knee extension (ICC  =  0.97, 95% CI: 0.91, 0.99). Validity was moderate for peak knee flexion (ICC  =  0.75, 95% CI: 0.38, 0.92) but poor for peak knee extension (ICC  =  0.37, 95% CI: 0, 0.73). The PR1 provides a reliable measure of isometric knee flexor and extensor strength in healthy adults that could be used in the clinical setting, but absolute values may not be comparable to strength assessment by gold-standard measures.

  7. Performance of different diagnostic criteria of overweight and obesity as predictors of metabolic syndrome in adolescents

    Directory of Open Access Journals (Sweden)

    Raphael Gonçalves de Oliveira

    2017-09-01

    Conclusions: Overweight and obesity using BMI showed a moderate association with MetS, regardless of the diagnostic criteria used. However, the IOTF criterion showed better predictive capacity for the presence of MetS than the WHO and the Conde and Monteiro criteria.

  8. Impact of scaling on the performance and reliability degradation of metal-contacts in NEMS devices

    KAUST Repository

    Dadgour, Hamed F.

    2011-04-01

    Nano-electro-mechanical switches (NEMS) offer new possibilities for the design of ultra energy-efficient systems; however, thus far, all the fabricated NEMS devices require high supply voltages that limit their applicability for logic designs. Therefore, research is being conducted to lower the operating voltages by scaling down the physical dimensions of these devices. However, the impact of device scaling on the electrical and mechanical properties of metal contacts in NEMS devices has not been thoroughly investigated in the literature. Such a study is essential because metal contacts play a critical role in determining the overall performance and reliability of NEMS. Therefore, the comprehensive analytical study presented in this paper highlights the performance and reliability degradations of such metal contacts caused by scaling. The proposed modeling environment accurately takes into account the impact of roughness of contact surfaces, elastic/plastic deformation of contacting asperities, and various inter-molecular forces between mating surfaces (such as Van der Waals and capillary forces). The modeling results are validated and calibrated using available measurement data. This scaling analysis indicates that the key contact properties of gold contacts (resistance, stiction and wear-out) deteriorate "exponentially" with scaling. Simulation results demonstrate that reliable (stiction-free) operation of very small contact areas (≈ 6nm x 6nm) will be a daunting task due to the existence of strong surface forces. Hence, contact degradation is identified as a major problem to the scaling of NEMS transistors. © 2011 IEEE.

  9. Verification criteria on the reliability of personal dosimetric services from x and gamma radiations; Criteri per la verifica dell'affidabilita di un servizio di dosimetria personale per radiazioni x e gamma

    Energy Technology Data Exchange (ETDEWEB)

    Borasi, G [Arcisp. S. Maria Nuova, USL 9, Reggio Emilia (Italy); Benco, A [CCE-CCR, Ispra, Varese (Italy); Kaftal, S [CESNEF - Politecnico, Milan (Italy)

    1990-07-15

    The paper presents the methods used by Working Group ENEA-EDP (Experts in Personal Dosimetry) to control the reliability of the Dosimetric Services operating in Italy and asking for the above controls on voluntary basis. Testing and irradiation test methods are explained as well as the evaluation criteria. The paper includes suggestions and guide-lines to gain the status of 'Reliable Service'. Technical equipment and operating procedures needed to pass the test are also illustrated. (author)

  10. Development of performance assessment methodology for establishment of quantitative acceptance criteria of near-surface radioactive waste disposal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, C. R.; Lee, E. Y.; Park, J. W.; Chang, G. M.; Park, H. Y.; Yeom, Y. S. [Korea Hydro and Nuclear Power Co., Ltd., Seoul (Korea, Republic of)

    2002-03-15

    The contents and the scope of this study are as follows : review of state-of-the-art on the establishment of waste acceptance criteria in foreign near-surface radioactive waste disposal facilities, investigation of radiological assessment methodologies and scenarios, investigation of existing models and computer codes used in performance/safety assessment, development of a performance assessment methodology(draft) to derive quantitatively radionuclide acceptance criteria of domestic near-surface disposal facility, preliminary performance/safety assessment in accordance with the developed methodology.

  11. Approach to reliability assessment

    International Nuclear Information System (INIS)

    Green, A.E.; Bourne, A.J.

    1975-01-01

    Experience has shown that reliability assessments can play an important role in the early design and subsequent operation of technological systems where reliability is at a premium. The approaches to and techniques for such assessments, which have been outlined in the paper, have been successfully applied in variety of applications ranging from individual equipments to large and complex systems. The general approach involves the logical and systematic establishment of the purpose, performance requirements and reliability criteria of systems. This is followed by an appraisal of likely system achievment based on the understanding of different types of variational behavior. A fundamental reliability model emerges from the correlation between the appropriate Q and H functions for performance requirement and achievement. This model may cover the complete spectrum of performance behavior in all the system dimensions

  12. Good performance in Japan is proof of continuing safety and reliability improvement practice

    International Nuclear Information System (INIS)

    Sumi, Y.

    1987-01-01

    Nuclear power is a vital energy supply source for both security and economy for such countries as Japan whose sources of energy are dependent on imported materials. This is the very reason why Japan gives her national priority to the improvement of nuclear power safety and reliability. As of the end of 1986, total nuclear power capacity owned and operated by private utility companies in Japan amounted to 24521 MW with 32 units sharing -- 19% of the total generating capacity. Moreover, during 1986 these units scored a remarkably high capacity factor of 76.2% and shared almost 28% of the nationwide electric power production, thereby contributing to a considerable saving of imported sources of energy. This outstanding record has been achieved by the parties concerned who dedicated themselves to furthering nuclear plant safety and reliability improvement. In this connection, this paper summarizes those key factors contributing to the good nuclear power plant performance of the Kansai Electric Power Company

  13. Visual perspective in autobiographical memories: reliability, consistency, and relationship to objective memory performance.

    Science.gov (United States)

    Siedlecki, Karen L

    2015-01-01

    Visual perspective in autobiographical memories was examined in terms of reliability, consistency, and relationship to objective memory performance in a sample of 99 individuals. Autobiographical memories may be recalled from two visual perspectives--a field perspective in which individuals experience the memory through their own eyes, or an observer perspective in which individuals experience the memory from the viewpoint of an observer in which they can see themselves. Participants recalled nine word-cued memories that differed in emotional valence (positive, negative and neutral) and rated their memories on 18 scales. Results indicate that visual perspective was the most reliable memory characteristic overall and is consistently related to emotional intensity at the time of recall and amount of emotion experienced during the memory. Visual perspective is unrelated to memory for words, stories, abstract line drawings or faces.

  14. Thermal Performance and Reliability Characterization of Bonded Interface Materials (BIMs): Preprint

    Energy Technology Data Exchange (ETDEWEB)

    DeVoto, D.; Paret, P.; Mihalic, M.; Narumanchi, S.; Bar-Cohen, A.; Matin, K.

    2014-08-01

    Thermal interface materials are an important enabler for low thermal resistance and reliable electronics packaging for a wide array of applications. There is a trend towards bonded interface materials (BIMs) because of their potential for low thermal resistivity (< 1 mm2K/W). However, BIMs induce thermomechanical stresses in the package and can be prone to failures and integrity risks. Deteriorated interfaces can result in high thermal resistance in the package and degradation and/or failure of the electronics. DARPA's Thermal Management Technologies program has addressed this challenge, supporting the development of mechanically-compliant, low resistivity nano-thermal interface (NTI) materials. In this work, we describe the testing procedure and report the results of NREL's thermal performance and reliability characterization of an initial sample of four different NTI-BIMs.

  15. Performance Based Failure Criteria of the Base Isolation System for Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, Jung Han; Kim, Min Kyu; Choi, In Kil

    2013-01-01

    The realistic approach to evaluate the failure state of the base isolation system is necessary. From this point of view, several concerns are reviewed and discussed in this study. This is the preliminary study for the performance based risk assessment of a base isolated nuclear power plant. The items to evaluate the capacity and response of an individual base isolator and a base isolation system were briefly outlined. However, the methodology to evaluate the realistic fragility of a base isolation system still needs to be specified. For the quantification of the seismic risk for a nuclear power plant structure, the failure probabilities of the structural component for the various seismic intensity levels need to be calculated. The failure probability is evaluated as the probability when the seismic response of a structure exceeds the failure criteria. Accordingly, the failure mode of the structural system caused by an earthquake vibration should be defined first. The type of a base isolator appropriate for a nuclear power plant structure is regarded as an elastometric rubber bearing with a lead core. The failure limit of the lead-rubber bearing (LRB) is not easy to be predicted because of its high nonlinearity and a complex loading condition by an earthquake excitation. Furthermore, the failure mode of the LRB system installed below the nuclear island cannot be simply determined because the basemat can be sufficiently supported if the number of damaged isolator is not much

  16. MAPPS (Maintenance Personnel Performance Simulation): a computer simulation model for human reliability analysis

    International Nuclear Information System (INIS)

    Knee, H.E.; Haas, P.M.

    1985-01-01

    A computer model has been developed, sensitivity tested, and evaluated capable of generating reliable estimates of human performance measures in the nuclear power plant (NPP) maintenance context. The model, entitled MAPPS (Maintenance Personnel Performance Simulation), is of the simulation type and is task-oriented. It addresses a number of person-machine, person-environment, and person-person variables and is capable of providing the user with a rich spectrum of important performance measures including mean time for successful task performance by a maintenance team and maintenance team probability of task success. These two measures are particularly important for input to probabilistic risk assessment (PRA) studies which were the primary impetus for the development of MAPPS. The simulation nature of the model along with its generous input parameters and output variables allows its usefulness to extend beyond its input to PRA

  17. The reliability and validity of a soccer-specific nonmotorised treadmill simulation (intermittent soccer performance test).

    Science.gov (United States)

    Aldous, Jeffrey W F; Akubat, Ibrahim; Chrismas, Bryna C R; Watkins, Samuel L; Mauger, Alexis R; Midgley, Adrian W; Abt, Grant; Taylor, Lee

    2014-07-01

    This study investigated the reliability and validity of a novel nonmotorised treadmill (NMT)-based soccer simulation using a novel activity category called a "variable run" to quantify fatigue during high-speed running. Twelve male University soccer players completed 3 familiarization sessions and 1 peak speed assessment before completing the intermittent soccer performance test (iSPT) twice. The 2 iSPTs were separated by 6-10 days. The total distance, sprint distance, and high-speed running distance (HSD) were 8,968 ± 430 m, 980 ± 75 m and 2,122 ± 140 m, respectively. No significant difference (p > 0.05) was found between repeated trials of the iSPT for all physiological and performance variables. Reliability measures between iSPT1 and iSPT2 showed good agreement (coefficient of variation: 0.80). Furthermore, the variable run phase showed HSD significantly decreased (p ≤ 0.05) in the last 15 minutes (89 ± 6 m) compared with the first 15 minutes (85 ± 7 m), quantifying decrements in high-speed exercise compared with the previous literature. This study validates the iSPT as a NMT-based soccer simulation compared with the previous match-play data and is a reliable tool for assessing and monitoring physiological and performance variables in soccer players. The iSPT could be used in a number of ways including player rehabilitation, understanding the efficacy of nutritional interventions, and also the quantification of environmentally mediated decrements on soccer-specific performance.

  18. An integrated methodology for the dynamic performance and reliability evaluation of fault-tolerant systems

    International Nuclear Information System (INIS)

    Dominguez-Garcia, Alejandro D.; Kassakian, John G.; Schindall, Joel E.; Zinchuk, Jeffrey J.

    2008-01-01

    We propose an integrated methodology for the reliability and dynamic performance analysis of fault-tolerant systems. This methodology uses a behavioral model of the system dynamics, similar to the ones used by control engineers to design the control system, but also incorporates artifacts to model the failure behavior of each component. These artifacts include component failure modes (and associated failure rates) and how those failure modes affect the dynamic behavior of the component. The methodology bases the system evaluation on the analysis of the dynamics of the different configurations the system can reach after component failures occur. For each of the possible system configurations, a performance evaluation of its dynamic behavior is carried out to check whether its properties, e.g., accuracy, overshoot, or settling time, which are called performance metrics, meet system requirements. Markov chains are used to model the stochastic process associated with the different configurations that a system can adopt when failures occur. This methodology not only enables an integrated framework for evaluating dynamic performance and reliability of fault-tolerant systems, but also enables a method for guiding the system design process, and further optimization. To illustrate the methodology, we present a case-study of a lateral-directional flight control system for a fighter aircraft

  19. PERFORMANCE-RELIABILITY – THE MAIN SUBJECT OF THE BANKING ANALYSIS OF THE CREDITED SOCIETIES

    Directory of Open Access Journals (Sweden)

    AVRAM (BOITOŞ CAMELIA

    2013-12-01

    Full Text Available Since the crediting activity occupies the primary role in any banking institution, the necessity of study and its analysis is required by following some steps both at a microeconomic level and at a macroeconomic one. Going over the theme, which aims at the importance of a thorough study of the clients' reliability for highlighting the existing risks in the banking activity in general, and particularly in the crediting activity, becomes as more interesting as their approach at the level of the member states of the European Union tends towards a common theme. Starting from these premises, we have considered as being extremely important the selection of a research theme which aims at the risks in the crediting activity, emphasizing the analysis of the clients' reliability both in the decision of crediting in order to assume the risk of credit and in determining the financial and banking performances. Being given the complexity of the existing risks in the banking activity in general and particularly of the credit risk, the clients' reliability represents an extremely important field, of research and application, bearing in mind both the actual stage of developing the Romanian banking system and the attempts of its alignment to the requirements imposed by the European Union.

  20. Design for High Performance, Low Power, and Reliable 3D Integrated Circuits

    CERN Document Server

    Lim, Sung Kyu

    2013-01-01

    This book describes the design of through-silicon-via (TSV) based three-dimensional integrated circuits.  It includes details of numerous “manufacturing-ready” GDSII-level layouts of TSV-based 3D ICs, developed with tools covered in the book. Readers will benefit from the sign-off level analysis of timing, power, signal integrity, and thermo-mechanical reliability for 3D IC designs.  Coverage also includes various design-for-manufacturability (DFM), design-for-reliability (DFR), and design-for-testability (DFT) techniques that are considered critical to the 3D IC design process. Describes design issues and solutions for high performance and low power 3D ICs, such as the pros/cons of regular and irregular placement of TSVs, Steiner routing, buffer insertion, low power 3D clock routing, power delivery network design and clock design for pre-bond testability. Discusses topics in design-for-electrical-reliability for 3D ICs, such as TSV-to-TSV coupling, current crowding at the wire-to-TSV junction and the e...

  1. Analysis of existing work-zone devices with MASH safety performance criteria.

    Science.gov (United States)

    2009-02-01

    Crashworthy, work-zone, portable sign support systems accepted under NCHRP Report No. 350 were analyzed to : predict their safety peformance according to the TL-3 MASH evaluation criteria. An analysis was conducted to determine : which hardware param...

  2. Performance of classification criteria for gout in early and established disease

    DEFF Research Database (Denmark)

    Taylor, William J; Fransen, Jaap; Dalbeth, Nicola

    2016-01-01

    OBJECTIVES: To compare the sensitivity and specificity of different classification criteria for gout in early and established disease. METHODS: This was a cross-sectional study of consecutive rheumatology clinic patients with joint swelling in which gout was defined by presence or absence...... of monosodium urate crystals as observed by a certified examiner at presentation. Early disease was defined as patient-reported onset of symptoms of 2 years or less. RESULTS: Data from 983 patients were collected and gout was present in 509 (52%). Early disease was present in 144 gout cases and 228 non.......3%/84.4% and 86.4%/63.6%. Criteria not requiring synovial fluid analysis had sensitivity and specificity of less than 80% in early and established disease. CONCLUSIONS: Existing classification criteria for gout have sensitivity of over 80% in early and established disease but currently available criteria that do...

  3. Microgrid Design Analysis Using Technology Management Optimization and the Performance Reliability Model

    Energy Technology Data Exchange (ETDEWEB)

    Stamp, Jason E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Eddy, John P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jensen, Richard P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Munoz-Ramos, Karina [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    Microgrids are a focus of localized energy production that support resiliency, security, local con- trol, and increased access to renewable resources (among other potential benefits). The Smart Power Infrastructure Demonstration for Energy Reliability and Security (SPIDERS) Joint Capa- bility Technology Demonstration (JCTD) program between the Department of Defense (DOD), Department of Energy (DOE), and Department of Homeland Security (DHS) resulted in the pre- liminary design and deployment of three microgrids at military installations. This paper is focused on the analysis process and supporting software used to determine optimal designs for energy surety microgrids (ESMs) in the SPIDERS project. There are two key pieces of software, an ex- isting software application developed by Sandia National Laboratories (SNL) called Technology Management Optimization (TMO) and a new simulation developed for SPIDERS called the per- formance reliability model (PRM). TMO is a decision support tool that performs multi-objective optimization over a mixed discrete/continuous search space for which the performance measures are unrestricted in form. The PRM is able to statistically quantify the performance and reliability of a microgrid operating in islanded mode (disconnected from any utility power source). Together, these two software applications were used as part of the ESM process to generate the preliminary designs presented by SNL-led DOE team to the DOD. Acknowledgements Sandia National Laboratories and the SPIDERS technical team would like to acknowledge the following for help in the project: * Mike Hightower, who has been the key driving force for Energy Surety Microgrids * Juan Torres and Abbas Akhil, who developed the concept of microgrids for military instal- lations * Merrill Smith, U.S. Department of Energy SPIDERS Program Manager * Ross Roley and Rich Trundy from U.S. Pacific Command * Bill Waugaman and Bill Beary from U.S. Northern Command * Tarek Abdallah, Melanie

  4. Clinical Neuropathology practice news 1-2014: Pyrosequencing meets clinical and analytical performance criteria for routine testing of MGMT promoter methylation status in glioblastoma

    Science.gov (United States)

    Preusser, Matthias; Berghoff, Anna S.; Manzl, Claudia; Filipits, Martin; Weinhäusel, Andreas; Pulverer, Walter; Dieckmann, Karin; Widhalm, Georg; Wöhrer, Adelheid; Knosp, Engelbert; Marosi, Christine; Hainfellner, Johannes A.

    2014-01-01

    Testing of the MGMT promoter methylation status in glioblastoma is relevant for clinical decision making and research applications. Two recent and independent phase III therapy trials confirmed a prognostic and predictive value of the MGMT promoter methylation status in elderly glioblastoma patients. Several methods for MGMT promoter methylation testing have been proposed, but seem to be of limited test reliability. Therefore, and also due to feasibility reasons, translation of MGMT methylation testing into routine use has been protracted so far. Pyrosequencing after prior DNA bisulfite modification has emerged as a reliable, accurate, fast and easy-to-use method for MGMT promoter methylation testing in tumor tissues (including formalin-fixed and paraffin-embedded samples). We performed an intra- and inter-laboratory ring trial which demonstrates a high analytical performance of this technique. Thus, pyrosequencing-based assessment of MGMT promoter methylation status in glioblastoma meets the criteria of high analytical test performance and can be recommended for clinical application, provided that strict quality control is performed. Our article summarizes clinical indications, practical instructions and open issues for MGMT promoter methylation testing in glioblastoma using pyrosequencing. PMID:24359605

  5. Managing wind turbine reliability and maintenance via performance-based contract

    DEFF Research Database (Denmark)

    Jin, Tongdan; Ding, Yi; Guo, Huairui

    2012-01-01

    between system cost, reliability and spare parts stocking. This analytical insight into the system performance allows the turbine manufacturer to optimize design, production, and after-sales services. The study aims to create a theoretical basis to facilitate the transition of the maintenance paradigm......Performance-based contracting (PBC) is reshaping the acquisition, operation, and maintenance of capital equipment. Under the PBC scheme, we propose a holistic approach for lowering the cost of wind turbine ownership while meeting the availability requirement. Our effects are focused on integrated...... firms who design and market wind turbines, and also provide maintenance and repair service. PBC differs from conventional service contracts in that the wind farmers compensate the service provider for the system performance, not the spare parts and repair labor. We explore the analytical relationship...

  6. Developing of Individual Instrument Performance Anxiety Scale: ValidityReliability Study

    Directory of Open Access Journals (Sweden)

    Esra DALKIRAN

    2016-07-01

    Full Text Available In this study, it is intended to develop a scale unique to our culture, concerning individual instrument performance anxiety of the students who are getting instrument training in the Department of Music Education. In the study, the descriptive research model is used and qualitative research techniques are utilized. The study population consists of the students attending the 23 universities which has Music Education Department. The sample of the study consists of 438 girls and 312 boys, totally 750 students who are studying in the Department of Music Education of randomly selected 10 universities. As a result of the explanatory and confirmatory factor analyses that were performed, a onedimensional structure consisting of 14 items was obtained. Also, t-scores and the coefficient scores of total item correlation concerning the distinguishing power of the items, the difference in the scores of the set of lower and upper 27% was calculated, and it was observed that the items are distinguishing as a result of both analyses. Of the scale, Cronbach's alpha coefficient of internal consistency was calculated as .94, and test-retest reliability coefficient was calculated as .93. As a result, a valid and reliable assessment and evaluation instrument that measures the exam performance anxiety of the students studying in the Department of Music Education, has been developed.

  7. Track 2- major components reliability and materials issues. Some performance indicators of PWR steam generators

    International Nuclear Information System (INIS)

    Milivojevic, S.; Spasojevic, D.; Riznic, J.

    2001-01-01

    The monitoring of operational performance is a crucial aspect of the management of equipment operation and maintenance in many industries, including nuclear and thermal power plants. Monitoring involves the collection and analysis of data on the operation. In these paper an analysis was made of steam generators in operation, i.e., their malfunctions during the plant life cycle with the aim of studying the characteristics of failure rate and repair rate. These values are necessary parameters if we are to determine the reliability and availability of the steam generator as a basis for the analysis of its effect on the safety and efficiency of the nuclear power plant. We analyzed IAEA available data for period from 1971 to 1998. Each steam generator was monitored individually during plants' lifetime. The data on steam generator failures were presented in uniform format, allowing the consistency in failure classification and data reporting. Operational presence of the analyzed steam generators is given for each calendar year and each lifetime year: the failure rate l and repair rate m with associated boundaries are calculated. The general trends in calendar years performance indicators (μ) of steam generators is investigated. The distributions of lifetime l and m are formed, as a complement to the analysis of calendar years performance indicators. With aspect of steam generators influence on reliability and availability of nuclear power plants, the empirical probability distribution for failure rates and repair rates are also constructed. (author)

  8. Performance and Reliability of Bonded Interfaces for High-temperature Packaging: Annual Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    DeVoto, Douglas J. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-10-19

    As maximum device temperatures approach 200 °Celsius, continuous operation, sintered silver materials promise to maintain bonds at these high temperatures without excessive degradation rates. A detailed characterization of the thermal performance and reliability of sintered silver materials and processes has been initiated for the next year. Future steps in crack modeling include efforts to simulate crack propagation directly using the extended finite element method (X-FEM), a numerical technique that uses the partition of unity method for modeling discontinuities such as cracks in a system.

  9. Performance and Reliability of Bonded Interfaces for High-Temperature Packaging (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Devoto, D.

    2014-11-01

    The thermal performance and reliability of sintered-silver is being evaluated for power electronics packaging applications. This will be experimentally accomplished by the synthesis of large-area bonded interfaces between metalized substrates that will be subsequently subjected to thermal cycles. A finite element model of crack initiation and propagation in these bonded interfaces will allow for the interpretation of degradation rates by a crack-velocity (V)-stress intensity factor (K) analysis. The experiment is outlined, and the modeling approach is discussed.

  10. Reliability and effect of sodium bicarbonate: buffering and 2000-m rowing performance.

    Science.gov (United States)

    Carr, Amelia J; Slater, Gary J; Gore, Christopher J; Dawson, Brian; Burke, Louise M

    2012-06-01

    The aim of this study was to determine the effect and reliability of acute and chronic sodium bicarbonate ingestion for 2000-m rowing ergometer performance (watts) and blood bicarbonate concentration [HCO3-]. In a crossover study, 7 well-trained rowers performed paired 2000-m rowing ergometer trials under 3 double-blinded conditions: (1) 0.3 grams per kilogram of body mass (g/kg BM) acute bicarbonate; (2) 0.5 g/kg BM daily chronic bicarbonate for 3 d; and (3) calcium carbonate placebo, in semi-counterbalanced order. For 2000-m performance and [HCO3-], we examined differences in effects between conditions via pairwise comparisons, with differences interpreted in relation to the likelihood of exceeding smallest worthwhile change thresholds for each variable. We also calculated the within-subject variation (percent typical error). There were only trivial differences in 2000-m performance between placebo (277 ± 60 W), acute bicarbonate (280 ± 65 W) and chronic bicarbonate (282 ± 65 W); however, [HCO3-] was substantially greater after acute bicarbonate, than with chronic loading and placebo. Typical error for 2000-m mean power was 2.1% (90% confidence interval 1.4 to 4.0%) for acute bicarbonate, 3.6% (2.5 to 7.0%) for chronic bicarbonate, and 1.6% (1.1 to 3.0%) for placebo. Postsupplementation [HCO3-] typical error was 7.3% (5.0 to 14.5%) for acute bicarbonate, 2.9% (2.0 to 5.7%) for chronic bicarbonate and 6.0% (1.4 to 11.9%) for placebo. Performance in 2000-m rowing ergometer trials may not substantially improve after acute or chronic bicarbonate loading. However, performances will be reliable with both acute and chronic bicarbonate loading protocols.

  11. Human reliability under sleep deprivation: Derivation of performance shaping factor multipliers from empirical data

    International Nuclear Information System (INIS)

    Griffith, Candice D.; Mahadevan, Sankaran

    2015-01-01

    This paper develops a probabilistic approach that could use empirical data to derive values of performance shaping factor (PSF) multipliers for use in quantitative human reliability analysis (HRA). The proposed approach is illustrated with data on sleep deprivation effects on performance. A review of existing HRA methods reveals that sleep deprivation is not explicitly included at present, and expert opinion is frequently used to inform HRA model multipliers. In this paper, quantitative data from empirical studies regarding the effect of continuous hours of wakefulness on performance measures (reaction time, accuracy, and number of lapses) are used to develop a method to derive PSF multiplier values for sleep deprivation, in the context of the SPAR-H model. Data is extracted from the identified studies according to the meta-analysis research synthesis method and used to investigate performance trends and error probabilities. The error probabilities in test and control conditions are compared, and the resulting probability ratios are suggested for use in informing the selection of PSF multipliers in HRA methods. Although illustrated for sleep deprivation, the proposed methodology is general, and can be applied to other performance shaping factors. - Highlights: • Method proposed to derive performance shaping factor multipliers from empirical data. • Studies reporting the effect of sleep deprivation on performance are analyzed. • Test data using psychomotor vigilance tasks are analyzed. • Error probability multipliers computed for reaction time, lapses, and accuracy measures.

  12. Perform qualify reliability-power tests by shooting common mistakes: practical problems and standard answers per Telcordia/Bellcore requests

    Science.gov (United States)

    Yu, Zheng

    2002-08-01

    Facing the new demands of the optical fiber communications market, almost all the performance and reliability of optical network system are dependent on the qualification of the fiber optics components. So, how to comply with the system requirements, the Telcordia / Bellcore reliability and high-power testing has become the key issue for the fiber optics components manufacturers. The qualification of Telcordia / Bellcore reliability or high-power testing is a crucial issue for the manufacturers. It is relating to who is the outstanding one in the intense competition market. These testing also need maintenances and optimizations. Now, work on the reliability and high-power testing have become the new demands in the market. The way is needed to get the 'Triple-Win' goal expected by the component-makers, the reliability-testers and the system-users. To those who are meeting practical problems for the testing, there are following seven topics that deal with how to shoot the common mistakes to perform qualify reliability and high-power testing: ¸ Qualification maintenance requirements for the reliability testing ¸ Lots control for preparing the reliability testing ¸ Sampling select per the reliability testing ¸ Interim measurements during the reliability testing ¸ Basic referencing factors relating to the high-power testing ¸ Necessity of re-qualification testing for the changing of producing ¸ Understanding the similarity for product family by the definitions

  13. Performance evaluation for epileptic electroencephalogram (EEG) detection by using Neyman-Pearson criteria and a support vector machine

    Science.gov (United States)

    Wang, Chun-mei; Zhang, Chong-ming; Zou, Jun-zhong; Zhang, Jian

    2012-02-01

    The diagnosis of several neurological disorders is based on the detection of typical pathological patterns in electroencephalograms (EEGs). This is a time-consuming task requiring significant training and experience. A lot of effort has been devoted to developing automatic detection techniques which might help not only in accelerating this process but also in avoiding the disagreement among readers of the same record. In this work, Neyman-Pearson criteria and a support vector machine (SVM) are applied for detecting an epileptic EEG. Decision making is performed in two stages: feature extraction by computing the wavelet coefficients and the approximate entropy (ApEn) and detection by using Neyman-Pearson criteria and an SVM. Then the detection performance of the proposed method is evaluated. Simulation results demonstrate that the wavelet coefficients and the ApEn are features that represent the EEG signals well. By comparison with Neyman-Pearson criteria, an SVM applied on these features achieved higher detection accuracies.

  14. SU-F-E-01: Pitfalls: Reliability and Performance of Diagnostic X-Sources

    Energy Technology Data Exchange (ETDEWEB)

    Behling, R [Philips Medical Systems DMC GmbHHamburg (United States)

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. The author is employee of Royal Philips.

  15. SU-F-E-01: Pitfalls: Reliability and Performance of Diagnostic X-Sources

    International Nuclear Information System (INIS)

    Behling, R

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. The author is employee of Royal Philips

  16. Accuracy and Reliability in the Prediction of End-of-Life Performance of Solar Generators

    Science.gov (United States)

    Rapp, Etienne

    2008-09-01

    The end-of-life power analysis of solar arrays is calculated using a combination of arithmetic and root square sums of loss factors. These loss factors are sometimes linked to degradations, sometimes linked to uncertainties. The uncertainties of the degradations are taken into account considering contractual "worst cases". This paper will put the first stones for a move "metrological" evaluation of the probable performance associated with a standard uncertainty. The turn from silicon to triple junction solar cells induces some changes in the degradation parameters of solar arrays: * The triple junction cells are more sensitive to UV darkening than silicon ones. * The cell voltage is higher and the current is lower. Then the cell strings are shorter, and there are more strings in parallel. This induces some changes in the reliability analyses and risk management. * The failure modes and failure rates of these cells have to be compared and discussed. We try to define improved rules to design solar arrays for end of life performance, for a better knowledge of the margins and a better reliability.

  17. A Correlated Model for Evaluating Performance and Energy of Cloud System Given System Reliability

    Directory of Open Access Journals (Sweden)

    Hongli Zhang

    2015-01-01

    Full Text Available The serious issue of energy consumption for high performance computing systems has attracted much attention. Performance and energy-saving have become important measures of a computing system. In the cloud computing environment, the systems usually allocate various resources (such as CPU, Memory, Storage, etc. on multiple virtual machines (VMs for executing tasks. Therefore, the problem of resource allocation for running VMs should have significant influence on both system performance and energy consumption. For different processor utilizations assigned to the VM, there exists the tradeoff between energy consumption and task completion time when a given task is executed by the VMs. Moreover, the hardware failure, software failure and restoration characteristics also have obvious influences on overall performance and energy. In this paper, a correlated model is built to analyze both performance and energy in the VM execution environment given the reliability restriction, and an optimization model is presented to derive the most effective solution of processor utilization for the VM. Then, the tradeoff between energy-saving and task completion time is studied and balanced when the VMs execute given tasks. Numerical examples are illustrated to build the performance-energy correlated model and evaluate the expected values of task completion time and consumed energy.

  18. Measures of small business success/performance: Importance, reliability and usability

    Directory of Open Access Journals (Sweden)

    Leković Božidar

    2015-01-01

    Full Text Available The main objective of this paper is to assess the reliability of selected measures of success/performance of small enterprises taking into account all the advantages and disadvantages of objective (traditional, financial and subjective (personal perception indicators. The realization of the basic objective will enable removal of doubt in different categories of success / performance of small businesses, which would be a secondary objective of the paper. The research methodology involves the use parametric procedures due to the characteristics of the selected variables and the number of observations in the sample. Univariate ANOVA and Pearson's coefficient correlation will be the main methods used. The basis of this study consists of data gathered from e-survey of 260 entrepreneurs/ owners/ managers of small enterprises in administrative sub-region of the Republic of Serbia. The analysis results show the correlation between subjective estimate of success of owners/ entrepreneurs/ managers and objective performance indicators, which can be characterized as complementary, meaning that subjective assessment as well as formally stated performance indicators are realistic. In addition, it is important to emphasize as an important result within the group of objective performance indicators, the differences between two groups, financial and non-financial, performance indicators.

  19. Disappointing performance of literature-derived selective screening criteria for asymptomatic Chlamydia trachomatis infection in an inner-city population

    NARCIS (Netherlands)

    van Valkengoed, I G; Boeke, A J; Morré, S A; van den Brule, A J; Meijer, C J; Devillé, W; Bouter, L M

    2000-01-01

    BACKGROUND: In an inner-city population with a low prevalence of Chlamydia trachomatis infection, selective screening may be indicated to increase the efficiency of screening. GOAL: To evaluate the performance of sets of selective screening criteria for asymptomatic Chlamydia trachomatis infection

  20. Using multiple and specific criteria to assess the predictive validity of the Big Five personality factors on academic performance.

    NARCIS (Netherlands)

    Kappe, F.R.; van der Flier, H.

    2010-01-01

    Multiple and specific academic performance criteria were used to examine the predictive validity of the Big Five personality traits. One hundred thirty-three students in a college of higher learning in The Netherlands participated in a naturally occurring field study. The results of the NEO-FFI were

  1. 77 FR 58607 - Office of Commercial Space Transportation Safety Approval Performance Criteria

    Science.gov (United States)

    2012-09-21

    ...: Notification of criteria used to evaluate the National Aerospace Training and Research (NASTAR) Center safety... approval for the ability of its Falcon 12/4 Altitude Chamber to replicate pressures experienced at altitude...). NASTAR's Falcon 12/4 Altitude Chamber is capable of replicating any pressure experienced at altitudes...

  2. 78 FR 28275 - Office of Commercial Space Transportation; Safety Approval Performance Criteria

    Science.gov (United States)

    2013-05-14

    ... provide as a service, scenario based physiology training, which includes hypobaric chamber training. BST may offer its scenario based physiology altitude training as a service to a prospective launch and...: Notification of criteria used to evaluate the Black Sky Training, Inc. (BST) safety approval application...

  3. Maximizing Energy Savings Reliability in BC Hydro Industrial Demand-side Management Programs: An Assessment of Performance Incentive Models

    Science.gov (United States)

    Gosman, Nathaniel

    of alternative performance incentive program models to manage DSM risk in BC. Three performance incentive program models were assessed and compared to BC Hydro's current large industrial DSM incentive program, Power Smart Partners -- Transmission Project Incentives, itself a performance incentive-based program. Together, the selected program models represent a continuum of program design and implementation in terms of the schedule and level of incentives provided, the duration and rigour of measurement and verification (M&V), energy efficiency measures targeted and involvement of the private sector. A multi criteria assessment framework was developed to rank the capacity of each program model to manage BC large industrial DSM risk factors. DSM risk management rankings were then compared to program costeffectiveness, targeted energy savings potential in BC and survey results from BC industrial firms on the program models. The findings indicate that the reliability of DSM energy savings in the BC large industrial sector can be maximized through performance incentive program models that: (1) offer incentives jointly for capital and low-cost operations and maintenance (O&M) measures, (2) allow flexible lead times for project development, (3) utilize rigorous M&V methods capable of measuring variable load, process-based energy savings, (4) use moderate contract lengths that align with effective measure life, and (5) integrate energy management software tools capable of providing energy performance feedback to customers to maximize the persistence of energy savings. While this study focuses exclusively on the BC large industrial sector, the findings of this research have applicability to all energy utilities serving large, energy intensive industrial sectors.

  4. Novel and conventional working fluid mixtures for solar Rankine cycles: Performance assessment and multi-criteria selection

    International Nuclear Information System (INIS)

    Mavrou, Paschalia; Papadopoulos, Athanasios I.; Stijepovic, Mirko Z.; Seferlis, Panos; Linke, Patrick; Voutetakis, Spyros

    2015-01-01

    This work investigates the performance of working fluid mixtures for use in solar ORC (Organic Rankine Cycle systems) with heat storage employing FPC (Flat Plate Collectors). Several mixtures are considered including conventional choices often utilized in ORC as well as novel mixtures previously designed using advanced computer aided molecular design methods (Papadopoulos et al., 2013). The impact of heat source variability on the ORC performance is assessed for different working fluid mixtures. Solar radiation is represented in detail through actual, hourly averaged data for an entire year. A multi-criteria mixture selection methodology unveils important trade-offs among several important system operating parameters and efficiently highlights optimum operating ranges. Such parameters include the ORC thermal efficiency, the net generated power, the volume ratio across the turbine, the mass flow rate of the ORC working fluid, the evaporator temperature glide, the temperature drop in the storage tank, the ORC total yearly operating duration, the required collector aperture area to generate 1 kW of power and the irreversibility. A mixture of neopentane – 2-fluoromethoxy-2-methylpropane at 70% neopentane is found to be the most efficient in all the considered criteria simultaneously. - Highlights: • Investigation of novel and conventional working fluid mixtures for solar ORCs. • Systematic, multi-criteria assessment methodology for mixture selection. • Simultaneous consideration of multiple important mixture performance criteria. • Effects of year-round solar variability in a solar ORC with heat storage tank

  5. The cognitive environment simulation as a tool for modeling human performance and reliability

    International Nuclear Information System (INIS)

    Woods, D.D.; Pople, H. Jr.; Roth, E.M.

    1990-01-01

    The US Nuclear Regulatory Commission is sponsoring a research program to develop improved methods to model the cognitive behavior of nuclear power plant (NPP) personnel. Under this program, a tool for simulating how people form intentions to act in NPP emergency situations was developed using artificial intelligence (AI) techniques. This tool is called Cognitive Environment Simulation (CES). The Cognitive Reliability Assessment Technique (or CREATE) was also developed to specify how CBS can be used to enhance the measurement of the human contribution to risk in probabilistic risk assessment (PRA) studies. The next step in the research program was to evaluate the modeling tool and the method for using the tool for Human Reliability Analysis (HRA) in PRAs. Three evaluation activities were conducted. First, a panel of highly distinguished experts in cognitive modeling, AI, PRA and HRA provided a technical review of the simulation development work. Second, based on panel recommendations, CES was exercised on a family of steam generator tube rupture incidents where empirical data on operator performance already existed. Third, a workshop with HRA practitioners was held to analyze a worked example of the CREATE method to evaluate the role of CES/CREATE in HRA. The results of all three evaluations indicate that CES/CREATE represents a promising approach to modeling operator intention formation during emergency operations

  6. A conceptual framework for a sports knee injury performance profile (SKIPP) and return to activity criteria (RTAC).

    Science.gov (United States)

    Logerstedt, David; Arundale, Amelia; Lynch, Andrew; Snyder-Mackler, Lynn

    2015-01-01

    Injuries to the knee, including intra-articular fractures, ligamentous ruptures, and meniscal and articular cartilage lesions, are commonplace within sports. Despite advancements in surgical techniques and enhanced rehabilitation, athletes returning to cutting, pivoting, and jumping sports after a knee injury are at greater risk of sustaining a second injury. The clinical utility of objective criteria presents a decision-making challenge to ensure athletes are fully rehabilitated and safe to return to sport. A system centered on specific indicators that can be used to develop a comprehensive profile to monitor rehabilitation progression and to establish return to activity criteria is recommended to clear athletes to begin a progressive and systematic approach to activities and sports. Integration of a sports knee injury performance profile with return to activity criteria can guide clinicians in facilitating an athlete's safe return to sport, prevention of subsequent injury, and life-long knee joint health.

  7. A conceptual framework for a sports knee injury performance profile (SKIPP and return to activity criteria (RTAC

    Directory of Open Access Journals (Sweden)

    David Logerstedt

    2015-10-01

    Full Text Available ABSTRACTInjuries to the knee, including intra-articular fractures, ligamentous ruptures, and meniscal and articular cartilage lesions, are commonplace within sports. Despite advancements in surgical techniques and enhanced rehabilitation, athletes returning to cutting, pivoting, and jumping sports after a knee injury are at greater risk of sustaining a second injury. The clinical utility of objective criteria presents a decision-making challenge to ensure athletes are fully rehabilitated and safe to return to sport. A system centered on specific indicators that can be used to develop a comprehensive profile to monitor rehabilitation progression and to establish return to activity criteria is recommended to clear athletes to begin a progressive and systematic approach to activities and sports. Integration of a sports knee injury performance profile with return to activity criteria can guide clinicians in facilitating an athlete's safe return to sport, prevention of subsequent injury, and life-long knee joint health.

  8. Embedded Sensors and Controls to Improve Component Performance and Reliability: Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Kisner, Roger A [ORNL; Melin, Alexander M [ORNL; Burress, Timothy A [ORNL; Fugate, David L [ORNL; Holcomb, David Eugene [ORNL; Wilgen, John B [ORNL; Miller, John M [ORNL; Wilson, Dane F [ORNL; Silva, Pamela C [ORNL; Whitlow, Lynsie J [ORNL; Peretz, Fred J [ORNL

    2012-10-01

    The overall project objective is to demonstrate improved reliability and increased performance made possible by deeply embedding instrumentation and controls (I&C) in nuclear power plant components. The project is employing a highly instrumented canned rotor, magnetic bearing, fluoride salt pump as its I&C technology demonstration vehicle. The project s focus is not primarily on pump design, but instead is on methods to deeply embed I&C within a pump system. However, because the I&C is intimately part of the basic millisecond-by-millisecond functioning of the pump, the I&C design cannot proceed in isolation from the other aspects of the pump. The pump will not function if the characteristics of the I&C are not embedded within the design because the I&C enables performance of the basic function rather than merely monitoring quasi-stable performance. Traditionally, I&C has been incorporated in nuclear power plant (NPP) components after their design is nearly complete; adequate performance was obtained through over-design. This report describes the progress and status of the project and provides a conceptual design overview for the embedded I&C pump.

  9. Simulation-based Assessment to Reliably Identify Key Resident Performance Attributes.

    Science.gov (United States)

    Blum, Richard H; Muret-Wagstaff, Sharon L; Boulet, John R; Cooper, Jeffrey B; Petrusa, Emil R; Baker, Keith H; Davidyuk, Galina; Dearden, Jennifer L; Feinstein, David M; Jones, Stephanie B; Kimball, William R; Mitchell, John D; Nadelberg, Robert L; Wiser, Sarah H; Albrecht, Meredith A; Anastasi, Amanda K; Bose, Ruma R; Chang, Laura Y; Culley, Deborah J; Fisher, Lauren J; Grover, Meera; Klainer, Suzanne B; Kveraga, Rikante; Martel, Jeffrey P; McKenna, Shannon S; Minehart, Rebecca D; Mitchell, John D; Mountjoy, Jeremi R; Pawlowski, John B; Pilon, Robert N; Shook, Douglas C; Silver, David A; Warfield, Carol A; Zaleski, Katherine L

    2018-04-01

    Obtaining reliable and valid information on resident performance is critical to patient safety and training program improvement. The goals were to characterize important anesthesia resident performance gaps that are not typically evaluated, and to further validate scores from a multiscenario simulation-based assessment. Seven high-fidelity scenarios reflecting core anesthesiology skills were administered to 51 first-year residents (CA-1s) and 16 third-year residents (CA-3s) from three residency programs. Twenty trained attending anesthesiologists rated resident performances using a seven-point behaviorally anchored rating scale for five domains: (1) formulate a clear plan, (2) modify the plan under changing conditions, (3) communicate effectively, (4) identify performance improvement opportunities, and (5) recognize limits. A second rater assessed 10% of encounters. Scores and variances for each domain, each scenario, and the total were compared. Low domain ratings (1, 2) were examined in detail. Interrater agreement was 0.76; reliability of the seven-scenario assessment was r = 0.70. CA-3s had a significantly higher average total score (4.9 ± 1.1 vs. 4.6 ± 1.1, P = 0.01, effect size = 0.33). CA-3s significantly outscored CA-1s for five of seven scenarios and domains 1, 2, and 3. CA-1s had a significantly higher proportion of worrisome ratings than CA-3s (chi-square = 24.1, P < 0.01, effect size = 1.50). Ninety-eight percent of residents rated the simulations more educational than an average day in the operating room. Sensitivity of the assessment to CA-1 versus CA-3 performance differences for most scenarios and domains supports validity. No differences, by experience level, were detected for two domains associated with reflective practice. Smaller score variances for CA-3s likely reflect a training effect; however, worrisome performance scores for both CA-1s and CA-3s suggest room for improvement.

  10. NDE performance demonstration in the US nuclear power industry - applications, costs, lessons learned, and connection to NDE reliability

    International Nuclear Information System (INIS)

    Ammirato, F.

    1997-01-01

    Periodic inservice inspection (ISI) of nuclear power plant components is performed in the United States to satisfy legal commitments and to provide plant owners with reliable information for managing degradation. Performance demonstration provides credible evidence that ISI will fulfill its objectives. This paper examines the technical requirements for inspection and discusses how these technical needs are used to develop effective performance demonstration applications. NDE reliability is discussed with particular reference to its role in structural integrity assessments and its connection with performance demonstration. It is shown that the role of NDE reliability can range from very small to critical depending on the particular application and must be considered carefully in design of inspection techniques and performance demonstration programs used to qualify the inspection. Finally, the costs, benefits, and problems associated with performance demonstration are reviewed along with lessons learned from more than 15 years of performance demonstration experience in the US. (orig.)

  11. TH-F-209-01: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    International Nuclear Information System (INIS)

    Behling, R.

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  12. TH-F-209-00: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    International Nuclear Information System (INIS)

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  13. TH-F-209-01: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Behling, R. [Philips Medical Systems DMC GmbH (United States)

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  14. TH-F-209-00: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  15. The experiences to improve plant performance and reliability of Ko-Ri nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ho Weon [Korea Electric Power Corp. Ko-Ri nuclear power division, Ko-Ri (Korea, Republic of)

    1998-07-01

    This paper provides a discussion of the lessons learned from operational experience and the future plans to improve performance of the Ko-Ri plant. To operate nuclear power plants safely with good performance is the only way to mitigate the negative image of nuclear power generation to the public and to enhance the economical benefit compared to other electrical generation method. Therefore, in a continuous effort to overcome a negative challenge from outside, we have driven an aggressive 'OCTF' campaign as part of safety. As a result of our efforts, the following remarkable achievements have been accomplished. (1) 3 times of OCTF during recent three years (2) Selected twice as a top notch power plant on the list of NEI magazine in terms of plant capacity factor (3) No scram recorded in 1997 for all 4 units at Ko-Ri site. Ko-Ri is now undergoing the large scale plant betterment projects for retaking-off our operating performance to the level of new challenge target. Such improvement of critical components in the reactor coolant system and turbine system greatly contribute to increase the safety and reliability of the plant and to shortening of the planned outage period as well as to reduction of radiation exposure and radwaste. (Cho, G. S.). 5 tabs., 10 figs.

  16. Modeling and Quantification of Team Performance in Human Reliability Analysis for Probabilistic Risk Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey C. JOe; Ronald L. Boring

    2014-06-01

    Probabilistic Risk Assessment (PRA) and Human Reliability Assessment (HRA) are important technical contributors to the United States (U.S.) Nuclear Regulatory Commission’s (NRC) risk-informed and performance based approach to regulating U.S. commercial nuclear activities. Furthermore, all currently operating commercial NPPs in the U.S. are required by federal regulation to be staffed with crews of operators. Yet, aspects of team performance are underspecified in most HRA methods that are widely used in the nuclear industry. There are a variety of "emergent" team cognition and teamwork errors (e.g., communication errors) that are 1) distinct from individual human errors, and 2) important to understand from a PRA perspective. The lack of robust models or quantification of team performance is an issue that affects the accuracy and validity of HRA methods and models, leading to significant uncertainty in estimating HEPs. This paper describes research that has the objective to model and quantify team dynamics and teamwork within NPP control room crews for risk informed applications, thereby improving the technical basis of HRA, which improves the risk-informed approach the NRC uses to regulate the U.S. commercial nuclear industry.

  17. The experiences to improve plant performance and reliability of Ko-Ri nuclear power plants

    International Nuclear Information System (INIS)

    Kang, Ho Weon

    1998-01-01

    This paper provides a discussion of the lessons learned from operational experience and the future plans to improve performance of the Ko-Ri plant. To operate nuclear power plants safely with good performance is the only way to mitigate the negative image of nuclear power generation to the public and to enhance the economical benefit compared to other electrical generation method. Therefore, in a continuous effort to overcome a negative challenge from outside, we have driven an aggressive 'OCTF' campaign as part of safety. As a result of our efforts, the following remarkable achievements have been accomplished. (1) 3 times of OCTF during recent three years (2) Selected twice as a top notch power plant on the list of NEI magazine in terms of plant capacity factor (3) No scram recorded in 1997 for all 4 units at Ko-Ri site. Ko-Ri is now undergoing the large scale plant betterment projects for retaking-off our operating performance to the level of new challenge target. Such improvement of critical components in the reactor coolant system and turbine system greatly contribute to increase the safety and reliability of the plant and to shortening of the planned outage period as well as to reduction of radiation exposure and radwaste. (Cho, G. S.). 5 tabs., 10 figs

  18. Performance and Reliability of Bonded Interfaces for High-Temperature Packaging. Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    DeVoto, Douglas [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-04-01

    Current generation automotive power electronics packages utilize silicon devices and lead-free solder alloys. To meet stringent technical targets for 2020 and beyond (for cost, power density, specific power, efficiency and reliability), wide-bandgap devices are being considered since they offer advantages such as operation at higher frequencies, voltages, and temperatures. Traditional power electronics packages must be redesigned to utilize the full potential of wide-bandgap devices, and the die- and substrate-attach layers are key areas where new material development and validation is required. Present solder alloys do not meet the performance requirements for these new package designs while also meeting cost and hazardous substance restrictions. Sintered silver (Ag) promises to meet the needs for die- and substrate-attach interfaces but synthesis optimization and reliability evaluation must be completed. Sintered Ag material was proposed as an alternative solution in power electronics packages almost 20 years back. However, synthesis pressure requirements up 40 MPa caused a higher complexity in the production process and more stringent flatness specifications for the substrates. Recently, several manufacturers have developed sintered Ag materials that require lower (3-5 MPa) or even no bonding pressures. Degradation mechanisms for these sintered Ag materials are not well known and need to be addressed. We are addressing these aspects to some extent in this project. We are developing generalized (i.e., independent of geometry) stress intensity factor versus cycles-to-failure relations for sintered Ag. Because sintered Ag is a relatively new material for automotive power electronics, the industry currently does not have a good understanding of recommended synthesis parameters or expected reliability under prescribed conditions. It is an important deliverable of this project to transfer findings to industry to eliminate barriers to using sintered Ag as a viable and

  19. Reliability, validity and description of timed performance of the Jebsen-Taylor Test in patients with muscular dystrophies.

    Science.gov (United States)

    Artilheiro, Mariana Cunha; Fávero, Francis Meire; Caromano, Fátima Aparecida; Oliveira, Acary de Souza Bulle; Carvas, Nelson; Voos, Mariana Callil; Sá, Cristina Dos Santos Cardoso de

    2017-12-08

    The Jebsen-Taylor Test evaluates upper limb function by measuring timed performance on everyday activities. The test is used to assess and monitor the progression of patients with Parkinson disease, cerebral palsy, stroke and brain injury. To analyze the reliability, internal consistency and validity of the Jebsen-Taylor Test in people with Muscular Dystrophy and to describe and classify upper limb timed performance of people with Muscular Dystrophy. Fifty patients with Muscular Dystrophy were assessed. Non-dominant and dominant upper limb performances on the Jebsen-Taylor Test were filmed. Two raters evaluated timed performance for inter-rater reliability analysis. Test-retest reliability was investigated by using intraclass correlation coefficients. Internal consistency was assessed using the Cronbach alpha. Construct validity was conducted by comparing the Jebsen-Taylor Test with the Performance of Upper Limb. The internal consistency of Jebsen-Taylor Test was good (Cronbach's α=0.98). A very high inter-rater reliability (0.903-0.999), except for writing with an Intraclass correlation coefficient of 0.772-1.000. Strong correlations between the Jebsen-Taylor Test and the Performance of Upper Limb Module were found (rho=-0.712). The Jebsen-Taylor Test is a reliable and valid measure of timed performance for people with Muscular Dystrophy. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  20. A fuzzy multi criteria approach for evaluating green supplier's performance in green supply chain with linguistic preferences

    DEFF Research Database (Denmark)

    Shen, Lixin; Olfat, Laya; Govindan, Kannan

    2013-01-01

    Today's international business environment has forced many firms to focus on supply chain management to gain a competitive advantage. During recent years, supplier selection process in the supply chain has become a key strategic consideration. With the growing worldwide awareness of environmental...... protection and the corresponding increase in legislation and regulations, green purchasing has become an important issue for companies to gain environmental sustainability. Traditionally, companies consider criteria such as price, quality and lead time, when evaluating supplier performance and do not give...... enough attention to environmental criteria as a means to evaluate suppliers. Now, many companies have begun to implement green supply chain management (GSCM) and to consider environmental issues and the measurement of their suppliers' environmental performance. This paper examines GSCM to propose a fuzzy...

  1. Quantitative developments in the cognitive reliability and error analysis method (CREAM) for the assessment of human performance

    International Nuclear Information System (INIS)

    Marseguerra, Marzio; Zio, Enrico; Librizzi, Massimo

    2006-01-01

    The current 'second generation' approaches in human reliability analysis focus their attention on the contextual conditions under which a given action is performed rather than on the notion of inherent human error probabilities, as was done in the earlier 'first generation' techniques. Among the 'second generation' methods, this paper considers the Cognitive Reliability and Error Analysis Method (CREAM) and proposes some developments with respect to a systematic procedure for computing probabilities of action failure. The starting point for the quantification is a previously introduced fuzzy version of the CREAM paradigm which is here further extended to include uncertainty on the qualification of the conditions under which the action is performed and to account for the fact that the effects of the common performance conditions (CPCs) on performance reliability may not all be equal. By the proposed approach, the probability of action failure is estimated by rating the performance conditions in terms of their effect on the action

  2. Principles of performance and reliability modeling and evaluation essays in honor of Kishor Trivedi on his 70th birthday

    CERN Document Server

    Puliafito, Antonio

    2016-01-01

    This book presents the latest key research into the performance and reliability aspects of dependable fault-tolerant systems and features commentary on the fields studied by Prof. Kishor S. Trivedi during his distinguished career. Analyzing system evaluation as a fundamental tenet in the design of modern systems, this book uses performance and dependability as common measures and covers novel ideas, methods, algorithms, techniques, and tools for the in-depth study of the performance and reliability aspects of dependable fault-tolerant systems. It identifies the current challenges that designers and practitioners must face in order to ensure the reliability, availability, and performance of systems, with special focus on their dynamic behaviors and dependencies, and provides system researchers, performance analysts, and practitioners with the tools to address these challenges in their work. With contributions from Prof. Trivedi's former PhD students and collaborators, many of whom are internationally recognize...

  3. Science-Based Simulation Model of Human Performance for Human Reliability Analysis

    International Nuclear Information System (INIS)

    Kelly, Dana L.; Boring, Ronald L.; Mosleh, Ali; Smidts, Carol

    2011-01-01

    Human reliability analysis (HRA), a component of an integrated probabilistic risk assessment (PRA), is the means by which the human contribution to risk is assessed, both qualitatively and quantitatively. However, among the literally dozens of HRA methods that have been developed, most cannot fully model and quantify the types of errors that occurred at Three Mile Island. Furthermore, all of the methods lack a solid empirical basis, relying heavily on expert judgment or empirical results derived in non-reactor domains. Finally, all of the methods are essentially static, and are thus unable to capture the dynamics of an accident in progress. The objective of this work is to begin exploring a dynamic simulation approach to HRA, one whose models have a basis in psychological theories of human performance, and whose quantitative estimates have an empirical basis. This paper highlights a plan to formalize collaboration among the Idaho National Laboratory (INL), the University of Maryland, and The Ohio State University (OSU) to continue development of a simulation model initially formulated at the University of Maryland. Initial work will focus on enhancing the underlying human performance models with the most recent psychological research, and on planning follow-on studies to establish an empirical basis for the model, based on simulator experiments to be carried out at the INL and at the OSU.

  4. Observer Variability and the Performance between Faculties and Residents: US Criteria for Benign and Malignant Thyroid Nodules

    International Nuclear Information System (INIS)

    Kim, Sung Hun; Park, Chang Suk; Jung, So Lyung

    2010-01-01

    To evaluate the interobserver variability and performance in the interpretation of ultrasonographic (US) findings of thyroid nodules. 72 malignant nodules and 61 benign nodules were enrolled as part of this study. Five faculty radiologists and four residents independently performed a retrospective analysis of the US images. The observers received one training session after the first interpretation and then performed a secondary interpretation. Agreement was analyzed by Cohen's kappa statistic. Degree of performance was analyzed using receiver operating characteristic (ROC) curves. Agreement between the faculties was fair-to-good for all criteria; however, between residents, agreement was poor-to-fair. The area under the ROC curves was 0.72, 0.62, and 0.60 for the faculties, senior residents, and junior residents, respectively. There was a significant difference in performance between the faculties and the residents (p < 0.05). There was a significant increase in the agreement for some criteria in the faculties and the senior residents after the training session, but no significant increase in the junior residents. Independent reporting of thyroid US performed by residents is undesirable. A continuous and specialized resident training is essential to enhance the degree of agreement and performance

  5. A BSC- EFQM method for evaluating and detecting performance measurement criteria: A case study of Malavan Footbal team

    Directory of Open Access Journals (Sweden)

    Heydar Shojaee Vazhnani

    2013-08-01

    Full Text Available This paper presents an empirical investigation to find important criteria for performance measurement based on two methods of balanced score card (BSC as well as European Foundation of Quality Management (EFQM methods. In order to determine the mission, vision, strategy and values we first review different documents including International Federation of football documentations, AFC and Football Federation of the Islamic Republic of Iran and Charter Club. Next, we determine the necessary criteria for performance measurement using interview with decision makers, design a questionnaire and distribute it among 57 players and coaching staff as well as experts, veterans and supporters club. Next, we study the results using t-student test and analyze them. The results are categorized in terms of four criteria of BSC method including internal processes, learning and growth, costumer and financial. In addition, key performance results based on the Excellence Model are classified according to nine areas of leadership, strategy, human resources, partnerships and resources, processes, customer results, human resource results and society.

  6. Validity and Reliability of Surface Electromyography Measurements from a Wearable Athlete Performance System

    Directory of Open Access Journals (Sweden)

    Scott K. Lynn, Casey M. Watkins, Megan A. Wong, Katherine Balfany, Daniel F. Feeney

    2018-06-01

    Full Text Available The Athos ® wearable system integrates surface electromyography (sEMG electrodes into the construction of compression athletic apparel. The Athos system reduces the complexity and increases the portability of collecting EMG data and provides processed data to the end user. The objective of the study was to determine the reliability and validity of Athos as compared with a research grade sEMG system. Twelve healthy subjects performed 7 trials on separate days (1 baseline trial and 6 repeated trials. In each trial subjects wore the wearable sEMG system and had a research grade sEMG system’s electrodes placed just distal on the same muscle, as close as possible to the wearable system’s electrodes. The muscles tested were the vastus lateralis (VL, vastus medialis (VM, and biceps femoris (BF. All testing was done on an isokinetic dynamometer. Baseline testing involved performing isometric 1 repetition maximum tests for the knee extensors and flexors and three repetitions of concentric-concentric knee flexion and extension at MVC for each testing speed: 60, 180, and 300 deg/sec. Repeated trials 2-7 each comprised 9 sets where each set included three repetitions of concentric-concentric knee flexion-extension. Each repeated trial (2-7 comprised one set at each speed and percent MVC (50%, 75%, 100% combination. The wearable system and research grade sEMG data were processed using the same methods and aligned in time. The amplitude metrics calculated from the sEMG for each repetition were the peak amplitude, sum of the linear envelope, and 95th percentile. Validity results comprise two main findings. First, there is not a significant effect of system (Athos or research grade system on the repetition amplitude metrics (95%, peak, or sum. Second, the relationship between torque and sEMG is not significantly different between Athos and the research grade system. For reliability testing, the variation across trials and averaged across speeds was 0.8%, 7

  7. Improving motor reliability in nuclear power plants: Volume 1, Performance evaluation and maintenance practices

    International Nuclear Information System (INIS)

    Subudhi, M.; Gunther, W.E.; Taylor, J.H.; Sugarman, A.C.; Sheets, M.W.

    1987-11-01

    This report constitutes the first of the three volumes under this NUREG. The report presents recommendations for developing a cost-effective program for performance evaluation and maintenance of electric motors in nuclear power plants. These recommendations are based on current industry practices, available techniques for monitoring degradation in motor components, manufacturer's recommendations, operating experience, and results from two laboratory tests on aged motors. Two laboratory test reports on a small and a large motor are presented in separate volumes of this NUREG. These provide the basis for the various functional indicators recommended for maintenance programs in this report. The overall preventive maintenance program is separated into two broad areas of activity aimed at mitigating the potential effects of equipment aging: Performance Evaluation and Equipment Maintenance. The latter involves actually maintaining the condition of the equipment while the former involves those activities undertaken to monitor degradation due to aging. These monitoring methods are further categorized into periodic testing, surveillance testing, continuous monitoring and inspections. This study focuses on the methods and procedures for performing the above activities to maintain the motors operationally ready in a nuclear facility. This includes an assessment of various functional indicators to determine their suitability for trending to monitor motor component condition. The intrusiveness of test methods and the present state-of-the-art for using the test equipment in a plant environment are discussed. In conclusion, implementation of the information provided in this report, will improve motor reliability in nuclear power plants. The study indicates the kinds of tests to conduct, how and when to conduct them, and to which motors the tests should be applied. 44 refs., 12 figs., 13 tabs

  8. Utilizing an ANP framework for prioritizing effective criteria on performance management in cooperative organization

    Directory of Open Access Journals (Sweden)

    Hosein Akhavan Alavi

    2012-09-01

    Full Text Available Performance management plays an essential role on increasing efficiency of business units. It helps find important barriers against a business unit helping us setup better strategies for handling troubles. In this paper, we present an empirical study to find important factors influencing performance management in cooperative organizations. The proposed study uses analytical hierarchy process to rank important factors in three groups of team level, individual and organization levels. The survey is based on receiving feedbacks from decision makers and making a pairwise comparison on measuring the relative importance of each criterion influencing performance management. The results of our survey indicate that setting appropriate standards for performance management is the most important item followed by relationship between organization structure and performance management, performance management based on future events. The other three factors including continuous improvement and updating systems, encouraging employee for change culture and relationship between future outlook and performance management are other important factors.

  9. Development, construct validity and test–retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball

    NARCIS (Netherlands)

    de Witte, AMH; Hoozemans, MJM; Berger, MAM; van der Slikke, R.M.A.; van der Woude, LHV; Veeger, H.E.J.

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation

  10. Development, construct validity and test-retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball

    NARCIS (Netherlands)

    de Witte, Annemarie M. H.; Hoozemans, Marco J. M.; Berger, Monique A. M.; van der Slikke, Rienk M. A.; van der Woude, Lucas H. V.; Veeger, Dirkjan (H. E. J)

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of

  11. Development, construct validity and test–retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball

    NARCIS (Netherlands)

    de Witte, Annemarie M H; Hoozemans, Marco J M; Berger, Monique A M; van der Slikke, Rienk M A; van der Woude, Lucas H V; Veeger, Dirkjan (H E J)

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of

  12. Human reliability analysis of performing tasks in plants based on fuzzy integral

    International Nuclear Information System (INIS)

    Washio, Takashi; Kitamura, Yutaka; Takahashi, Hideaki

    1991-01-01

    The effective improvement of the human working conditions in nuclear power plants might be a solution for the enhancement of the operation safety. The human reliability analysis (HRA) gives a methodological basis of the improvement based on the evaluation of human reliability under various working conditions. This study investigates some difficulties of the human reliability analysis using conventional linear models and recent fuzzy integral models, and provides some solutions to the difficulties. The following practical features of the provided methods are confirmed in comparison with the conventional methods: (1) Applicability to various types of tasks (2) Capability of evaluating complicated dependencies among working condition factors (3) A priori human reliability evaluation based on a systematic task analysis of human action processes (4) A conversion scheme to probability from indices representing human reliability. (author)

  13. A Bayesian reliability approach to the performance assessment of a geological waste repository

    International Nuclear Information System (INIS)

    Flueck, J.A.; Singh, A.K.

    1992-01-01

    This paper discusses the task of selecting a suitable site for a high-level waste disposal repository (HLWR) which certainly is a complex one in that one must address both engineering and economic factors of the proposed facility and site as well as environmental, public health, safety, and sociopolitical factors. Acknowledging the complexity of the siting problem for a HLWR leads one to readily conclude that a formal analysis, including the use of a performance assessment model (PAM), is needed to assist the designated decision makers in their task of selecting a suitable site. The overall goal of a PAM is to aid the decision makers in making the best possible technical siting decision. For a number of reason, the authors believe that the combining of both Bayesian decision theory and reliability methodology provides the best approach to constructing a useful PAM for assisting in the siting of a HLWR. This combination allows one to formally integrate existing relevant information, professional judgement, and component model outputs to produce conditionally estimated probabilities for a decision tree approach to the radionuclide release problem of a proposed HLWR. If loss functions are available, this also allows one to calculate the expected costs or losses from possible radionuclide releases. This latter calculation may be very important in selecting the final site from among a number of alternative sites

  14. The Effect of Patient Characteristics and Sleep Quality on Visual Field Performance Reliability

    Directory of Open Access Journals (Sweden)

    Swarup S. Swaminathan

    2018-01-01

    Full Text Available Purpose. To investigate the association of automated visual field (VF reliability indices (false positive [FP], false negative [FN], and fixation loss [FL] and sleep quality, VF experience, and age. Methods. Prospective, cross-sectional study. Adult patients (age ≥ 18 years completing automated VF testing were invited to participate. Baseline participant characteristics were obtained, and all participants were asked to complete the Pittsburgh Sleep Quality Index (PSQI questionnaire. Nonparametric Spearman correlations and logistical regression models were performed. Results. 63 patients were enrolled. Lower PSQI score was correlated with higher percentage (% FL in the right eye (p=0.03. Fewer prior VF was significantly correlated with higher %FP in the right eye (p=0.008. Older age was significantly correlated with higher %FN in the left eye (p=0.01. Greater mean deviation (MD and pattern standard deviation (PSD were strongly correlated with higher %FN in the right (p=0.02 and 0.002, resp. and left eyes (p=0.01 and 0.02, resp.. Conclusion. In this prospective, cross-sectional study, worse MD and PSD are strongly correlated with increased FN in both eyes. Increased FN in the left eye associated with older age might be attributable to test fatigue. Worse sleep quality is associated with decreased FL in the right eye.

  15. Performance and Reliability of DSRC Vehicular Safety Communication: A Formal Analysis

    Directory of Open Access Journals (Sweden)

    2009-02-01

    Full Text Available IEEE- and ASTM-adopted dedicated short range communications (DSRC standard toward 802.11p is a key enabling technology for the next generation of vehicular safety communication. Broadcasting of safety messages is one of the fundamental services in DSRC. There have been numerous publications addressing design and analysis of such broadcast ad hoc system based on the simulations. For the first time, an analytical model is proposed in this paper to evaluate performance and reliability of IEEE 802.11a-based vehicle-to-vehicle (V2V safety-related broadcast services in DSRC system on highway. The proposed model takes two safety services with different priorities, nonsaturated message arrival, hidden terminal problem, fading transmission channel, transmission range, IEEE 802.11 backoff counter process, and highly mobile vehicles on highway into account. Based on the solutions to the proposed analytic model, closed-form expressions of channel throughput, transmission delay, and packet reception rates are derived. From the obtained numerical results under various offered traffic and network parameters, new insights and enhancement suggestions are given.

  16. IMPROVEMENT OF THE ASSESSMENT CRITERIA FOR SCIENTIFIC RESEARCH PROJECTS - A PREMISE OF INCREASING THE UNIVERSITY SCIENTIFIC RESEARCH PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Cristian Marius TOMA

    2013-10-01

    Full Text Available The National Plan for Research, Development and Innovation 2007 – 2013, called herein the National Plan II, represents the main instrument used to implement the National Strategy for Research, Development and Innovation. Universities play a unique role in the development of the knowledge-based society, through its contribution to knowledge generation, transmission, dissemination and utilization. The essential role of the university is to shape the highly qualified human resource, a process that implies a symbiosis between the education and research, the education system performances contributing in this way to a great extent to the society development. The highly qualified human resource represents an important asset of a nation. This study is dedicated to the analysis of the assessment criteria for the Exploratory Research Projects (ERP handed in the competitions in 2007, 2008, 2011 and 2012 and to highlight the importance of improving the assessment criteria in order to improve their quality.

  17. Admissions Criteria as Predictors of Academic Performance in a Three-Year Pharmacy Program at a Historically Black Institution

    Science.gov (United States)

    Parmar, Jayesh R.; Purnell, Miriam; Lang, Lynn A.

    2016-01-01

    Objective. To determine the ability of University of Maryland Eastern Shore School of Pharmacy’s admissions criteria to predict students’ academic performance in a 3-year pharmacy program and to analyze transferability to African-American students. Methods. Statistical analyses were conducted on retrospective data for 174 students. Didactic and experiential scores were used as measures of academic performance. Results. Pharmacy College Admission Test (PCAT), grade point average (GPA), interview, and observational scores combined with previous pharmacy experience and biochemistry coursework predicted the students' academic performance except second-year (P2) experiential performance. For African-American students, didactic performance positively correlated with PCAT writing subtests, while the experiential performance positively correlated with previous pharmacy experience and observational score. For nonAfrican-American students, didactic performance positively correlated with PCAT multiple-choice subtests, and experiential performance with interview score. The prerequisite GPA positively correlated with both of the student subgroups’ didactic performance. Conclusion. Both PCAT and GPA were predictors of didactic performance, especially in nonAfrican-Americans. Pharmacy experience and observational scores were predictors of experiential performance, especially in African-Americans. PMID:26941432

  18. Reliability and Validity of the Turkish Language Version of the Test of Performance Strategies

    Directory of Open Access Journals (Sweden)

    Miçooğulları Bülent Okan

    2017-03-01

    Full Text Available The aim of the present study was to examine the psychometric properties of the Test of Performance Strategies (TOPS; Thomas et al., 1999 on the Turkish population. The TOPS was designed to assess eight psychological skills and strategies used by athletes in competition (activation, automaticity, emotional control, goal-setting, imagery, relaxation, self-talk, and negative thinking and the same strategies, except negative thinking is replaced by attentional control used in training. The sample of the study included athletes who were training and competing in a wide variety of sports across a broad range of performance standards. The final sample consisted of 433 males (mean ± s: age 22.47 ± 5.30 years and 187 females (mean ± s: age 20.97 ± 4.78 years, 620 athletes in total (mean ± s: age 21.25 ± 4.87 years who voluntarily participated; TOPS was administered to all participants. Afterward, Confirmatory Factor Analysis (CFA was conducted by Analysis Moments of Structures (AMOS 18. Comparative fit index (CFI, non-normed fit index (NNFI and root mean square error of approximation (RMSEA were used to verify whether the model fit the data. Goodness-of-fit statistics were CFI= .91, NNFI= .92 and RMSEA= .056. These values showed that the tested model is coherent at a satisfactory level. Moreover, results of confirmatory factor analyses revealed that a total of four items (two items from competition and two from practice within the subscale of automaticity have been removed. The 28 items within the remaining seven subscales have been validated. In conclusion, Turkish version of TOPS is a valid and reliable instrument to assess the psychological skills and strategies used by athletes in competition and practices.

  19. The diagnostic performance of imaging methods in ARVC using the 2010 Task Force criteria

    DEFF Research Database (Denmark)

    Borgquist, Rasmus; Haugaa, Kristina H; Gilljam, Thomas

    2014-01-01

    , fractional area shortening 31 ± 9 vs. 39 ± 9% (P performance was low; sensitivity 50% and specificity 70%, positive predictive value 80% and negative predictive value 37...... evaluation of subtle structural changes in the right ventricle may be unreliable, and the diagnostic performance of CMR compared with echocardiography should be reflected in the guidelines....

  20. Waste package performance criteria for deepsea disposal of low-level radioactive wastes

    International Nuclear Information System (INIS)

    Colombo, P.; Fuhrmann, M.

    1988-07-01

    Sea disposal of low-level radioactive waste began in the United States in 1946, and was placed under the licensing authority of the Atomic Energy Commission (AEC). The practice stopped completely in 1970. Most of the waste disposed of at sea was packaged in second- hand or reconditioned 55-gallon drums filled with cement so that the average package density was sufficiently greater than that of sea water to ensure sinking. It was assumed that all the contents would eventually be released since the packages were not designed or required to remain intact for sustained periods of time after descent to the ocean bottom. Recently, there has been renewed interest in ocean disposal, both in this country and abroad, as a waste management alternative to land burial. The Marine Protection, Research and Sanctuaries Act of 1972 (PL 92-532) gives EPA the regulatory responsibility for ocean dumping of all materials, including radioactive waste. This act prohibits the ocean disposal of high-level radioactive waste and requires EPA to control the ocean disposal of all other radioactive waste through the issuance of permits. In implementing its permit authorities, EPA issued on initial set of regulations and criteria in 1973 to control the disposal of material into the ocean waters. It was in these regulations that EPA initially introduced the general requirement of isolation and containment of radioactive waste as the basic operating philosophy. 37 refs

  1. Application of objective clinical human reliability analysis (OCHRA) in assessment of technical performance in laparoscopic rectal cancer surgery.

    Science.gov (United States)

    Foster, J D; Miskovic, D; Allison, A S; Conti, J A; Ockrim, J; Cooper, E J; Hanna, G B; Francis, N K

    2016-06-01

    Laparoscopic rectal resection is technically challenging, with outcomes dependent upon technical performance. No robust objective assessment tool exists for laparoscopic rectal resection surgery. This study aimed to investigate the application of the objective clinical human reliability analysis (OCHRA) technique for assessing technical performance of laparoscopic rectal surgery and explore the validity and reliability of this technique. Laparoscopic rectal cancer resection operations were described in the format of a hierarchical task analysis. Potential technical errors were defined. The OCHRA technique was used to identify technical errors enacted in videos of twenty consecutive laparoscopic rectal cancer resection operations from a single site. The procedural task, spatial location, and circumstances of all identified errors were logged. Clinical validity was assessed through correlation with clinical outcomes; reliability was assessed by test-retest. A total of 335 execution errors identified, with a median 15 per operation. More errors were observed during pelvic tasks compared with abdominal tasks (p technical performance of laparoscopic rectal surgery.

  2. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    Science.gov (United States)

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  3. Reliability of EP3OS symptom criteria and nasal endoscopy in the assessment of chronic rhinosinusitis--a GA² LEN study

    NARCIS (Netherlands)

    Tomassen, P.; Newson, R. B.; Hoffmans, R.; Lötvall, J.; Cardell, L. O.; Gunnbjörnsdóttir, M.; Thilsing, T.; Matricardi, P.; Krämer, U.; Makowska, J. S.; Brozek, G.; Gjomarkaj, M.; Howarth, P.; Loureiro, C.; Toskala, E.; Fokkens, W.; Bachert, C.; Burney, P.; Jarvis, D.

    2011-01-01

    The European Position Paper on Rhinosinusitis and Nasal Polyps (EP3OS) incorporates symptomatic, endoscopic, and radiologic criteria in the clinical diagnosis of chronic rhinosinusitis (CRS), while in epidemiological studies, the definition is based on symptoms only. We aimed to assess the

  4. Quality assurance criteria for Waste Isolation Pilot Plant performance assessment modeling

    International Nuclear Information System (INIS)

    1995-07-01

    The US Department of Energy (DOE) is developing the Waste Isolation Pilot Plant (WIPP) as a deep geologic repository for transuranic (TRU) and TRU-mixed wastes generated by DOE Defense Program activities. Regulatory agencies, including the Environmental Protection Agency (EPA) and New Mexico Environment Department, will be forced to rely upon system modeling to determine the potential compliance of the WIPP facility with federal regulations. Specifically, long-term modeling efforts are focused on compliance with 40 CFR Part 268, ''Land Disposal Restrictions,'' and 40 CFR Part 191, ''Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level, and Transuranic Radioactive Wastes.'' DOE plans to use the similar conceptual models and numerical codes to demonstrate compliance under both of these regulations. Sandia National Laboratories (SNL) has been developing a system model that will be used to demonstrate potential waste migration from the WIPP facility. Because the geologic system underlying the WIPP site is not completely understood, the software code to model the system must be developed to exacting standards for its predictions to be reliable and defensible. This is a complex model that consists of many submodules used to describe various migration pathways and processes that affect potential waste migration

  5. PERFORMANCE CRITERIA of RUBBER UKM BASED ON COOPERATIVE USING BALANCED SCORECARD METHOD

    Directory of Open Access Journals (Sweden)

    Dessy Iriani Putri

    2017-01-01

    Full Text Available Small and Medium Enterprises (UKM of Usaha Mandiri is the only UKM in Putri Hijau district, North Bengkulu that carries out its activities based on cooperative principles. The UKM was established in 2010 due to the rubber farmer’s concern about their future. In the last few years, the rubber price has declined, resulting in the decreasing performance of UKM Usaha Mandiri’s.  The objective of this research is to analyze the performance of UKM of Usaha Mandiri.  The method used is balanced scorecard (BSC and Focus Group Discussion (FGD to identify the UKM’s strategic aim and the BSC value. The result of the research shows that the performance of UKM of Usaha Mandiri   started to decline from 2013–2015.  The BSC score from 2011–2015 was 112.93 (excellent, 141.84 (excellent, 95.41 (excellent, 47.42 (average and 81.62 (very good.  The decline of the performance was due to the decline of natural rubber price.  The conclusion for the research is that in 2015 the performance of UKM of Usaha Mandiri   was categorized as very good (BSC method with the most contribution from growth and learning perspective.        Keywords : Balanced scorecard, BSC, cooperation, performance measurement, UKM

  6. The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain

    Science.gov (United States)

    2013-01-01

    Background This study investigates the reliability of muscle performance tests using cost- and time-effective methods similar to those used in clinical practice. When conducting reliability studies, great effort goes into standardising test procedures to facilitate a stable outcome. Therefore, several test trials are often performed. However, when muscle performance tests are applied in the clinical setting, clinicians often only conduct a muscle performance test once as repeated testing may produce fatigue and pain, thus variation in test results. We aimed to investigate whether cervical muscle performance tests, which have shown promising psychometric properties, would remain reliable when examined under conditions similar to those of daily clinical practice. Methods The intra-rater (between-day) and inter-rater (within-day) reliability was assessed for five cervical muscle performance tests in patients with (n = 33) and without neck pain (n = 30). The five tests were joint position error, the cranio-cervical flexion test, the neck flexor muscle endurance test performed in supine and in a 45°-upright position and a new neck extensor test. Results Intra-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.48-0.82), the cranio-cervical flexion test (ICC ≥ 0.69), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.68) and in a 45°-upright position (ICC ≥ 0.41) with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement (ICC = 0.14-0.41). Likewise, inter-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.51-0.75), the cranio-cervical flexion test (ICC ≥ 0.85), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.70) and in a 45°-upright position (ICC ≥ 0.56). However, only slight to fair agreement was found for the neck extensor test (ICC

  7. Correlation Relationship of Performance Shaping Factors (PSFs) for Human Reliability Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bheka, M. Khumalo; Kim, Jonghyun [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2014-10-15

    At TMI-2, operators permitted thousands of gallons of water to escape from the reactor plant before realizing that the coolant pumps were behaving abnormally. The coolant pumps were then turned off, which in turn led to the destruction of the reactor itself as cooling was completely lost within the core. Human also plays a role in many aspects of complex systems e.g. in design and manufacture of hardware, interface between human and system and also in maintaining such systems as well as for coping with unusual events that place the NPP system at a risk. This is why human reliability analysis (HRA) - an aspect of risk assessments which systematically identifies and analyzes the causes and consequences of human decisions and actions - is important in nuclear power plant operations. It either upgrades or degrades human performance; therefore it has an impact on the possibility of error. These PSFs can be used in various HRA methods to estimate Human Error Probabilities (HEPs). There are many current HRA methods who propose sets of PSFs for normal operation mode of NPP. Some of these PSFs in the sets have some degree of dependency and overlap. Overlapping PSFs introduce error in HEP evaluations due to the fact that some elements are counted more than once in data; this skews the relationship amongst PSF and masks the way that the elements interact to affect performance. This study uses a causal model that represents dependencies and relationships amongst PSFs for HEP evaluation during normal NPP operational states. The model is built taking into consideration the dependencies among PSFs and thus eliminating overlap. The use of an interdependent model of PSFs is expected to produce more accurate HEPs compared to other current methods. PSF sets produced in this study can be further used as nodes (variables) and directed arcs (causal influence between nodes) in HEP evaluation methods such as Bayesian belief (BN) networks. This study was done to estimate the relationships

  8. Two non-tracking solar collectors: Design criteria and performance analysis

    International Nuclear Information System (INIS)

    Ratismith, Wattana; Inthongkhum, Anusorn; Briggs, John

    2014-01-01

    Highlights: • A collector module designed to capture solar radiation efficiently is proposed. • Two different compound parabolic trough designs are examined and tested. • A novel design with a flat base trough and vertical absorber operates efficiently in direct and diffuse sunlight. - Abstract: We propose fixed (non-tracking) configurations of solar light collector modules which are designed to operate efficiently throughout the day, i.e. for varying incident angles of direct sunlight, and in conditions of diffuse solar irradiation. We present two trough designs of compound parabolic collector (CPC) type. One, a more conventional double-parabolic trough, has the absorber plate perpendicular to the vertical axis of the trough cross-section. The other, of a new flat-base shape, has the absorber plate parallel. The collectors have two novel features appropriate to non-tracking. The first is a smoothing of the power output over the day by the simple expedient of arranging three troughs tilted at different angles. The second is the original design of the flat-base trough allowing optimal interception of the caustic surfaces of this non-focussing device. By ray-tracing analysis of the different trough shapes and absorber plate orientation, we emphasise the design criteria for achievement of a high intercept factor throughout the day without tracking and demonstrate the superiority of the flat-base collector over the double-parabolic design. In test experiments we show that the high temperatures (≈180 °C) necessary for some industrial process heat applications can be achieved. Also test results of the efficiency of the proposed systems are presented which indicate that the flat-base trough with vertical absorber plate is superior to the double-parabolic trough with horizontal absorber plate

  9. Reliability centered maintenance : a case study of railway transit maintenance to achieve optimal performance.

    Science.gov (United States)

    2010-12-01

    The purpose of this qualitative case study was to identify the types of obstacles and patterns experienced by a single heavy rail transit agency located in North America that embedded a Reliability Centered Maintenance (RCM) Process. The outcome of t...

  10. Fundamental criteria for the design of high-performance Josephson nondestructive readout random access memory cells and experimental confirmation

    International Nuclear Information System (INIS)

    Henkels, W.H.

    1979-01-01

    Fundamental design criteria for Josephson nondestructive readout random access memory (NDRO RAM) cells are presented, within the context of an LSI array environment. Emphasis is placed upon principles which are relevant to high performance. The criteria are elucidated via a specific design which is simulated and then experimentally evaluated in a technology with a smallest critical dimension of 5 μm. The specific cell differs from previously tested Josephson NDRO cells in several respects; namely, the cell stores only approx.8Phi 0 , employs interferometer gates and an external damping resistor, allows switching into device resonances, and eliminates the need for a special initialization cycle. The cell-selection scheme, employing triple coincidence, results in larger operating margins and smaller operating currents than have previously been achieved. The large operating margins and all basic cell design criteria were experimentally verified. The experimental interferometer gate characteristics were analyzed in detail and found to be describable by simple models. In addition, it was discovered that single flux quantum transitions in the interferometer gates could be exploited beneficially in order to enhance the insensitivity of operating margins to fabrication tolerances

  11. Reliability of one-repetition maximum performance in people with chronic heart failure.

    Science.gov (United States)

    Ellis, Rachel; Holland, Anne E; Dodd, Karen; Shields, Nora

    2018-02-24

    Evaluate intra-rater and inter-rater reliability of the one-repetition maximum strength test in people with chronic heart failure. Intra-rater and inter-rater reliability study. A public tertiary hospital in northern metropolitan Melbourne. Twenty-four participants (nine female, mean age 71.8 ± 13.1 years) with mild to moderate heart failure of any aetiology. Lower limb strength was assessed by determining the maximum weight that could be lifted using a leg press. Intra-rater reliability was tested by one assessor on two separate occasions . Inter-rater reliability was tested by two assessors in random order. Intra-class correlation coefficients and 95% confidence intervals were calculated. Bland and Altman analyses were also conducted, including calculation of mean differences between measures ([Formula: see text]) and limits of agreement . Ten intra-rater and 21 inter-rater assessments were completed. Excellent intra-rater (intra-class correlation coefficient 2,1 0.96) and inter-rater (intra-class correlation coefficient 2,1 0.93) reliability was found. Intra-rater assessment showed less variability (mean difference 4.5 kg, limits of agreement -8.11 to 17.11 kg) than inter-rater agreement (mean difference -3.81 kg, limits of agreement -23.39 to 15.77 kg). One-repetition maximum determined using a leg press is a reliable measure in people with heart failure. Given its smaller limits of agreement, intra-rater testing is recommended. Implications for Rehabilitation Using a leg press to determine a one-repetition maximum we were able to demonstrate excellent inter-rater and intra-rater reliability using an intra-class correlation coefficient. The Bland and Altman levels of agreement were wide for inter-rater reliability and so we recommend using one assessor if measuring change in strength within an individual over time.

  12. Evaluating the reliability of multi-body mechanisms: A method considering the uncertainties of dynamic performance

    International Nuclear Information System (INIS)

    Wu, Jianing; Yan, Shaoze; Zuo, Ming J.

    2016-01-01

    Mechanism reliability is defined as the ability of a certain mechanism to maintain output accuracy under specified conditions. Mechanism reliability is generally assessed by the classical direct probability method (DPM) derived from the first order second moment (FOSM) method. The DPM relies strongly on the analytical form of the dynamic solution so it is not applicable to multi-body mechanisms that have only numerical solutions. In this paper, an indirect probability model (IPM) is proposed for mechanism reliability evaluation of multi-body mechanisms. IPM combines the dynamic equation, degradation function and Kaplan–Meier estimator to evaluate mechanism reliability comprehensively. Furthermore, to reduce the amount of computation in practical applications, the IPM is simplified into the indirect probability step model (IPSM). A case study of a crank–slider mechanism with clearance is investigated. Results show that relative errors between the theoretical and experimental results of mechanism reliability are less than 5%, demonstrating the effectiveness of the proposed method. - Highlights: • An indirect probability model (IPM) is proposed for mechanism reliability evaluation. • The dynamic equation, degradation function and Kaplan–Meier estimator are used. • Then the simplified form of indirect probability model is proposed. • The experimental results agree well with the predicted results.

  13. Improving behavioral performance under full attention by adjusting response criteria to changes in stimulus predictability.

    Science.gov (United States)

    Katzner, Steffen; Treue, Stefan; Busse, Laura

    2012-09-04

    One of the key features of active perception is the ability to predict critical sensory events. Humans and animals can implicitly learn statistical regularities in the timing of events and use them to improve behavioral performance. Here, we used a signal detection approach to investigate whether such improvements in performance result from changes of perceptual sensitivity or rather from adjustments of a response criterion. In a regular sequence of briefly presented stimuli, human observers performed a noise-limited motion detection task by monitoring the stimulus stream for the appearance of a designated target direction. We manipulated target predictability through the hazard rate, which specifies the likelihood that a target is about to occur, given it has not occurred so far. Analyses of response accuracy revealed that improvements in performance could be accounted for by adjustments of the response criterion; a growing hazard rate was paralleled by an increasing tendency to report the presence of a target. In contrast, the hazard rate did not affect perceptual sensitivity. Consistent with previous research, we also found that reaction time decreases as the hazard rate grows. A simple rise-to-threshold model could well describe this decrease and attribute predictability effects to threshold adjustments rather than changes in information supply. We conclude that, even under conditions of full attention and constant perceptual sensitivity, behavioral performance can be optimized by dynamically adjusting the response criterion to meet ongoing changes in the likelihood of a target.

  14. The Effect of Epoxy Molding Compound Floor Life to Reliability Performance and mold ability for QFN Package

    Science.gov (United States)

    Peanpunga, Udom; Ugsornrat, Kessararat; Thorlor, Panakamol; Sumithpibul, Chalermsak

    2017-09-01

    This research studied about an epoxy molding compound (EMC) floor life to reliability performance of integrated circuit (IC) package. Molding is the process for protecting the die of IC package form mechanical and chemical reaction from external environment by shaping EMC. From normal manufacturing process, the EMC is stored in the frozen at 5oC and left at around room temperature for aging time or floor life before molding process. The EMC floor life effect to its properties and reliability performance of IC package. Therefore, this work interested in varied the floor life of EMC before molding process to analyze properties of EMC such as spiral flow length, gelation time, and viscosity. In experiment, the floor life of EMC was varied to check the effect of its property to reliability performance. The EMC floor life were varied from 0 hours to 60 hours with a step of 12 hours and observed wire sweep, incomplete EMC, and delamination inside the packages for 3x3, 5x5 and 8x8 mm2 of QFN packages. The evaluation showed about clearly effect of EMC floor life to IC packaging reliability. EMC floor life is not any concern for EMC property, moldabilty, and reliability from 0 hours to 48 hours for molding process of 3x3,5x5 and 8x8 mm2 QFN packaging manufacturing

  15. “Weather” transit is reliable? Using AVL data to explore tram performance in Melbourne, Australia

    Directory of Open Access Journals (Sweden)

    Mahmoud Mesbah

    2015-06-01

    Full Text Available This paper uses automatic vehicle location (AVL records to investigate the effect of weather conditions on the travel time reliability of on-road rail transit, through a case study of the Melbourne streetcar (tram network. The datasets available were an extensive historical AVL dataset as well as weather observations. The sample size used in the analysis included all trips made over a period of five years (2006–2010 inclusive, during the morning peak (7 am–9 am for fifteen randomly selected radial tram routes, all traveling to the Melbourne CBD. Ordinary least square (OLS regression analysis was conducted to create a linear model, with tram travel time being the dependent variable. An alternative formulation of the model is also compared. Travel time was regressed on various weather effects including precipitation, air temperature, sea level pressure and wind speed; as well as indicator variables for weekends, public holidays and route numbers to investigate a correlation between weather condition and the on-time performance of the trams. The results indicate that only precipitation and air temperature are significant in their effect on tram travel time. The model demonstrates that on average, an additional millimeter of precipitation during the peak period adversely affects the average travel time during that period by approximately 8 s, that is, rainfall tends to increase the travel time. The effect of air temperature is less intuitive, with the model indicating that trams adhere more closely to schedule when the temperature is different in absolute terms to the mean operating conditions (taken as 15 °C.

  16. Further Development of the Assessment of Military Multitasking Performance: Iterative Reliability Testing.

    Directory of Open Access Journals (Sweden)

    Margaret M Weightman

    Full Text Available The Assessment of Military Multitasking Performance (AMMP is a battery of functional dual-tasks and multitasks based on military activities that target known sensorimotor, cognitive, and exertional vulnerabilities after concussion/mild traumatic brain injury (mTBI. The AMMP was developed to help address known limitations in post concussive return to duty assessment and decision making. Once validated, the AMMP is intended for use in combination with other metrics to inform duty-readiness decisions in Active Duty Service Members following concussion. This study used an iterative process of repeated interrater reliability testing and feasibility feedback to drive modifications to the 9 tasks of the original AMMP which resulted in a final version of 6 tasks with metrics that demonstrated clinically acceptable ICCs of > 0.92 (range of 0.92-1.0 for the 3 dual tasks and > 0.87 (range 0.87-1.0 for the metrics of the 3 multitasks. Three metrics involved in recording subject errors across 2 tasks did not achieve ICCs above 0.85 set apriori for multitasks (0.64 and above 0.90 set for dual-tasks (0.77 and 0.86 and were not used for further analysis. This iterative process involved 3 phases of testing with between 13 and 26 subjects, ages 18-42 years, tested in each phase from a combined cohort of healthy controls and Service Members with mTBI. Study findings support continued validation of this assessment tool to provide rehabilitation clinicians further return to duty assessment methods robust to ceiling effects with strong face validity to injured Warriors and their leaders.

  17. New design of engineered safety features-component control system to improve performance and reliability

    International Nuclear Information System (INIS)

    Kim, S.T.; Jung, H.W.; Lee, S.J.; Cho, C.H.; Kim, D.H.; Kim, H.

    2006-01-01

    Full text: Full text: The Engineered Safety Features-Component Control System (ESF-CCS) controls the engineered safety features of a Nuclear Power Plant such as Solenoid Operated Valves (SOV), Motor Operated Valves (MOV), pumps, dampers, etc. to mitigate the effects of a Design Basis Accident (DBA) or an abnormal operation. ESF-CCS serves as an interface system between the Plant Protection System (PPS) and remote actuation devices. ESF-CCS is composed of fault tolerant Group Controllers GC, Loop Controllers (LC), ESF-CCS Test and Interface Processor (ETIP) and Cabinet Operator Module (COM) and Control Channel Gateway (CCG) etc. GCs in each division are designed to be fully independent triple configuration, which perform system level NSSS and BOP ESFAS logic (2-out-of-4 logic and l-out-of-2 logic, respectively) making it possible to test each GC individually during normal operation. In the existing configuration, the safety-related plant component control is part of the Plant Control System (PCS) non-safety system. For increased safety and reliability, this design change incorporates this part into the LCs, and is therefore designed according to the safety-critical system procedures. The test and diagnosis capabilities of ETIP and COM are reinforced. By means of an automatic periodic test for all main functions of the system, it is possible to quickly determine an abnormal status of the system, and to decrease the elapsed time for tests, thus effectively increasing availability. ESF-CCS consists of four independent divisions (A, B, C, and D) in the Advanced Power Reactor 1400 (APR1400). One prototype division is being manufactured and will be tested

  18. Missouri River, Gavins Point Dam - Lewis and Clark Lake, Nebraska and South Dakota, Embankment Criteria and Performance Report.

    Science.gov (United States)

    1982-05-01

    PM T.CTIO. 16 8. DIYISIOU AND CLOSE ib tio/ 17 A iaJ,3,"q1tY Cod,: TC-1 A w!-, iaui’,orI D-I ist SPOIa;I K 9. SEEPAGE CONTROL 18 9.1 Relief Wells 18...DonoeCn vIH & COePS OF ENG11NEERS OMAHA NEFIRASKiA ENIBANKMENT CRITERIA AND PERFORMANCE REPORT P LATE A-2 I< _ I I- / LEWIS A CLARK LAKE Is --- 4"- C

  19. FMS Scores Change With Performers' Knowledge of the Grading Criteria-Are General Whole-Body Movement Screens Capturing "Dysfunction"?

    Science.gov (United States)

    Frost, David M; Beach, Tyson A C; Callaghan, Jack P; McGill, Stuart M

    2015-11-01

    Deficits in joint mobility and stability could certainly impact individuals' Functional Movement Screen (FMS) scores; however, it is also plausible that the movement patterns observed are influenced by the performers' knowledge of the grading criteria. Twenty-one firefighters volunteered to participate, and their FMS scores were graded before and immediately after receiving knowledge of the movement patterns required to achieve a perfect score on the FMS. Standardized verbal instructions were used to administer both screens, and the participants were not provided with any coaching or feedback. Time-synchronized sagittal and frontal plane videos were used to grade the FMS. The firefighters significantly (p injury risk.

  20. Designing sustainable concrete on the basis of equivalence performance: assessment criteria for safety

    NARCIS (Netherlands)

    Visser, J.H.M.; Bigaj, A.J.

    2014-01-01

    In order not to hampers innovations, the Dutch National Building Regulations (NBR), allow an alternative approval route for new building materials. It is based on the principles of equivalent performance which states that if the solution proposed can be proven to have the same level of safety,

  1. Key Performance Indicators of Public Universities Based on Quality Assessment Criteria in Thailand

    Science.gov (United States)

    Sukboonyasatit, Kritsana; Thanapaisarn, Chaiwit; Manmar, Lampang

    2011-01-01

    The research objective was to develop public universities' key performance indicators. Qualitative research and interviews were employed with each public university's senior executive and quality assessors. The sample group was selected by the office of the public sector development commission and Thailand's public universities can be separated…

  2. A Multi-Actor Multi-Criteria Analysis of the Performance of Global Cities

    NARCIS (Netherlands)

    Kourtit, K.; Macharis, C.; Nijkamp, P.

    2014-01-01

    The strong world-wide urbanisation trend calls for a repositioning of cities, especially the large cities with a global impact. These cities tend to become economic, logistic and political powerhouses and are increasingly involved in a competition on their integral performance. The present paper

  3. Some Aspects of Psychophysiological Support of Crew Member's Performance Reliability in Space Flight

    Science.gov (United States)

    Nechaev, A. P.; Myasnikov, V. I.; Stepanova, S. I.; Isaev, G. F.; Bronnikov, S. V.

    The history of cosmonautics demonstrates many instances in which only crewmembers' intervention allowed critical situations to be resolved, or catastrophes to be prevented. However, during "crew-spacecraft" system operation human is exposed by influence of numerous flight factors, and beforehand it is very difficult to predict their effects on his functional state and work capacity. So, the incidents are known when unfavorable alterations of crewmember's psychophysiological state (PPS) provoked errors in task performance. The objective of the present investigation was to substantiate the methodological approach directed to increase reliability of a crewmember performance (human error prevention) by means of management of his/her PPS. The specific aims of the investigation were: 1) to evaluate the statistical significance of the interrelation between crew errors (CE) and crewmember's PPS, and 2) to develop the way of PPS management. At present, there is no conventional method to assess combined effect of flight conditions (microgravity, confinement, psychosocial factors, etc.) on crewmembers' PPS. For this purpose experts of the Medical Support Group (psychoneurologists and psychologists) at the Moscow Mission Control Center analyze information received during radio and TV contacts with crew. Peculiarities of behavior, motor activity, sleep, speech, mood, emotional reactions, well-being and sensory sphere, trend of dominant interests and volitional acts, signs of deprivation phenomena are considered as separate indicators of crewmember's PPS. The set of qualitative symptoms reflecting PPS alterations and corresponding to them ratings (in arbitrary units) was empirically stated for each indicator. It is important to emphasize that symptoms characterizing more powerful PPS alterations have higher ratings. Quantitative value of PPS integral parameter is calculating by adding up the ratings of all separate indicators over a day, a week, or other temporal interval (in

  4. A Note on the Validity and Reliability of Multi-Criteria Decision Analysis for the Benefit-Risk Assessment of Medicines.

    Science.gov (United States)

    Garcia-Hernandez, Alberto

    2015-11-01

    The comparative evaluation of benefits and risks is one of the most important tasks during the development, market authorization and post-approval pharmacovigilance of medicinal products. Multi-criteria decision analysis (MCDA) has been recommended to support decision making in the benefit-risk assessment (BRA) of medicines. This paper identifies challenges associated with bias or variability that practitioners may encounter in this field and presents solutions to overcome them. The inclusion of overlapping or preference-complementary criteria, which are frequent violations to the assumptions of this model, should be avoided. For each criterion, a value function translates the original outcomes into preference-related scores. Applying non-linear value functions to criteria defined as the risk of suffering a certain event during the study introduces specific risk behaviours in this prescriptive, rather than descriptive, model and is therefore a questionable practice. MCDA uses weights to compare the importance of the model criteria with each other; during their elicitation a frequent situation where (generally favourable) mild effects are directly traded off against low probabilities of suffering (generally unfavourable) severe effects during the study is known to lead to biased and variable weights and ought to be prevented. The way the outcomes are framed during the elicitation process, positively versus negatively for instance, may also lead to differences in the preference weights, warranting an appropriate justification during each implementation. Finally, extending the weighted-sum MCDA model into a fully inferential tool through a probabilistic sensitivity analysis is desirable. However, this task is troublesome and should not ignore that clinical trial endpoints generally are positively correlated.

  5. Development of a reliable and clinically useful Italian version of the Axis II for the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD)

    OpenAIRE

    Macrì, Ludovica Antonella; Deli, Velria; Deli, Roberto

    2012-01-01

    Background: Multiple-language versions of the same psychometric instrument are increasingly needed, but simply translating an English version word-to-word into another language is not adequate to account for linguistic and cultural differences. Our aim was to alidate an Italian version of the Axis II of the Research Diagnostic Criteria for temporomandibular disorders (RDC/TMD) and to test its reproducibility in order to use this important diagnostic instr...

  6. Model Multi Criteria Decision Making with Fuzzy ANP Method for Performance Measurement Small Medium Enterprise (SME)

    Science.gov (United States)

    Rahmanita, E.; Widyaningrum, V. T.; Kustiyahningsih, Y.; Purnama, J.

    2018-04-01

    SMEs have a very important role in the development of the economy in Indonesia. SMEs assist the government in terms of creating new jobs and can support household income. The number of SMEs in Madura and the number of measurement indicators in the SME mapping so that it requires a method.This research uses Fuzzy Analytic Network Process (FANP) method for performance measurement SME. The FANP method can handle data that contains uncertainty. There is consistency index in determining decisions. Performance measurement in this study is based on a perspective of the Balanced Scorecard. This research approach integrated internal business perspective, learning, and growth perspective and fuzzy Analytic Network Process (FANP). The results of this research areframework a priority weighting of assessment indicators SME.

  7. Optimizing the use of the "state-of-the-art" performance criteria.

    Science.gov (United States)

    Haeckel, Rainer; Wosniok, Werner; Streichert, Thomas

    2015-05-01

    The organizers of the first EFLM Strategic Conference "Defining analytical performance goals" identified three models for defining analytical performance goals in laboratory medicine. Whereas the highest level of model 1 (outcome studies) is difficult to implement, the other levels are more or less based on subjective opinions of experts, with models 2 (based on biological variation) and 3 (defined by the state-of-the-art) being more objective. A working group of the German Society of Clinical Chemistry and Laboratory Medicine (DGKL) proposes a combination of models 2 and 3 to overcome some disadvantages inherent to both models. In the new model, the permissible imprecision is not defined as a constant proportion of biological variation but by a non-linear relationship between permissible analytical and biological variation. Furthermore, the permissible imprecision is referred to the target quantity value. The biological variation is derived from the reference interval, if appropriate, after logarithmic transformation of the reference limits.

  8. Performance evaluation and parametric choice criteria of a Brayton pumped thermal electricity storage system

    International Nuclear Information System (INIS)

    Guo, Juncheng; Cai, Ling; Chen, Jincan; Zhou, Yinghui

    2016-01-01

    A more realistic thermodynamic model of the pumped thermal electricity storage (PTES) system consisting of a Brayton cycle and a reverse Brayton cycle is proposed, where the internal and external irreversible losses are took into account and several important controlling parameters, e.g., the pressure ratio and heat flows of the two isobaric processes in the Brayton cycle, are introduced. Analytic expressions for the round trip efficiency and power output of the PTES system are derived. The general performance characteristics of the PTES system are revealed. The optimal relationship between the round trip efficiency and the power output is obtained. The influences of some important controlling parameters on the performance characteristics of the PTES system are discussed and the optimally operating regions of these parameters are determined. - Highlights: • A cycle model of the Brayton pumped thermal electricity storage system is proposed. • Internal and external irreversible losses are considered. • Maximum power output and efficiency of the system are calculated. • Optimum performance characteristics of the system are revealed. • Rational ranges of key controlling parameters are determined.

  9. Performance of nuclear power plants and analysis of some factors affecting their operational reliability and economy

    International Nuclear Information System (INIS)

    Kozak, M.; Havel, S.

    1989-09-01

    In Czechoslovakia, there are eight WWER 440 type reactors in operation at present. Since their introduction into operation, nuclear power plants in Czechoslovakia have exhibited high reliability. In the paper, total parameters of reliability with an analysis of causes affecting negatively their annual utilization are presented. Existence of a computerized information system for acquisition, recording and evaluation of reliability-significant data from operation and its feedback to designers and manufacturers of nuclear power plant equipment and components is a basic requirement of a systematic assurance of the needed level of nuclear power plant reliability. The information system is used simultaneously also for realistic evaluation of aging of equipment and systems. Analysis of the state of equipment is important mainly in the final stage of the NPP during consideration of further extension of its service life. Environmental effects of the Czechoslovak NPPs are very low (favourable). It follows from comparison of annual dose equivalents of the Czechoslovak NPPs operational personnel with the foreign NPPs that the values recorded in Czechoslovakia belong to the lowest ones. In conclusion, some ways of assurance of operational safety and reliability of the Czechoslovak nuclear power plants including the role of the State regulatory body are briefly discussed. (author). 3 tabs

  10. Long-term pavement performance monitoring and the revision of performance criteria for high modulus asphalt in South Africa

    CSIR Research Space (South Africa)

    Komba, Julius

    2016-09-01

    Full Text Available Enrobé à Module Élevé (EME) technology, a High Modulus Asphalt (HiMA), was originally developed in France. The technology is primarily suitable for construction of heavily trafficked routes, airports and container terminals. The key performance...

  11. EFFECT OF LUBRICANT CONTAMINATION ON THE PERFORMANCE AND RELIABILITY OF HEAT PUMPS CHARGED WITH R-407C.

    Science.gov (United States)

    The report gives results of the development of new data that can be used to determine the effect of mineral oil contamination on the reliability of a heat pump system operating with a new hydrofluorocarbon mixture and polyol ester lubricant, to assess any performance degradation ...

  12. The Validity and Reliability of the Gymaware Linear Position Transducer for Measuring Counter-Movement Jump Performance in Female Athletes

    Science.gov (United States)

    O'Donnell, Shannon; Tavares, Francisco; McMaster, Daniel; Chambers, Samuel; Driller, Matthew

    2018-01-01

    The current study aimed to assess the validity and test-retest reliability of a linear position transducer when compared to a force plate through a counter-movement jump in female participants. Twenty-seven female recreational athletes (19 ± 2 years) performed three counter-movement jumps simultaneously using the linear position transducer and…

  13. Proceedings of the 1998 Photovoltaic Performance and Reliability Workshop; Cocoa Beach, Florida; November 3-5, 1998

    Energy Technology Data Exchange (ETDEWEB)

    Kroposki, B.

    1998-12-17

    This proceedings is the compilation of all papers presented at the 11th PV Performance and Reliability Workshop held at the Doubletree Hotel in Cocoa Beach, Florida, on November 3-5, 1998. The workshop was hosted by the Florida Solar Energy Center. This year's workshop included presentations from 29 speakers and had 110 attendees.

  14. Multi-rate h2 tracking control with mixed continuous-discrete performance criteria

    International Nuclear Information System (INIS)

    Kahane, A.C.; Palmor, Z.J.; Mirkin, L.

    1998-01-01

    Control goals defined both in continuous and discrete time arise naturally in many sampled-data tracking control problems. The design methods found in the literature deal with each kind of those control goals separately, over-emphasizing one kind at the expense of the other. We formulate and solve these tracking control problems as an H2 optimization problem with a mixed continuous/discrete performance criterion. It is argued that the proposed setup enables tradeoff between the various control goals in a natural manner and thus leads to better tracking characteristics

  15. Pilot test of ANSI draft standard N13.29 environmental dosimetry -- Performance criteria for testing

    International Nuclear Information System (INIS)

    Klemic, G.; Shebell, P.; Monetti, M.; Raccah, F.; Sengupta, S.

    1998-09-01

    American National Standards Institute Draft N13.29 describes performance tests for environmental radiation dosimetry providers. If approved it would be the first step toward applying the types of performance testing now required in personnel dosimetry to environmental radiation monitoring. The objective of this study was to pilot test the draft standard, before it undergoes final balloting, on a small group of dosimetry providers that were selected to provide a mix of facility types, thermoluminescent dosimeter designs and monitoring program applications. The first phase of the pilot test involved exposing dosimeters to laboratory photon, beta, and x-ray sources at routine and accident dose levels. In the second phase, dosimeters were subjected to ninety days of simulated environmental conditions in an environmental chamber that cycled through extremes of temperature and humidity. Two out of seven participants passed all categories of the laboratory testing phase, and all seven passed the environmental test phase. While some relatively minor deficiencies were uncovered in the course of the pilot test, the results show that draft N13.29 describes useful tests that could be appropriate for environmental dosimetry providers. An appendix to this report contains recommendations that should be addressed by the N13.29 working group before draft N13.29 is submitted for balloting

  16. A criterion of the performance of thermometric systems of high metrological reliability

    International Nuclear Information System (INIS)

    Sal'nikov, N.L.; Filimonov, E.V.

    1995-01-01

    Monitoring temperature regimes is an important part of ensuring the operational safety of a nuclear power plant. Therefore, high standards are imposed upon the reliability of the primary information on the heat field of the object obtained from different sensors, and it is urgent to develop methods of evaluating the metrological reliability of these sensors. THe main sources of thermometric information at nuclear power plants are contact temperature sensors, the most widely used of these being thermoelectric converters (TEC) and thermal resistance converters (TRC)

  17. An Impact of Thermodynamic Processes in Human Bodies on Performance Reliability of Individuals

    Directory of Open Access Journals (Sweden)

    Smalko Zbigniew

    2015-01-01

    Full Text Available The article presents the problem of the influence of thermodynamic factors on human fallibility in different zones of thermal discomfort. Describes the processes of energy in the human body. Been given a formal description of the energy balance of the human body thermoregulation. Pointed to human reactions to temperature changes of internal and external environment, including reactions associated with exercise. The methodology to estimate and determine the reliability of indicators of human basal acting in different zones of thermal discomfort. The significant effect of thermodynamic factors on the reliability and security ofperson.

  18. 49 CFR 639.27 - Minimum criteria.

    Science.gov (United States)

    2010-10-01

    ... dollar value to any non-financial factors that are considered by using performance-based specifications..., DEPARTMENT OF TRANSPORTATION CAPITAL LEASES Cost-Effectiveness § 639.27 Minimum criteria. In making the... used where possible and appropriate: (a) Operation costs; (b) Reliability of service; (c) Maintenance...

  19. Effects of Differential Item Functioning on Examinees' Test Performance and Reliability of Test

    Science.gov (United States)

    Lee, Yi-Hsuan; Zhang, Jinming

    2017-01-01

    Simulations were conducted to examine the effect of differential item functioning (DIF) on measurement consequences such as total scores, item response theory (IRT) ability estimates, and test reliability in terms of the ratio of true-score variance to observed-score variance and the standard error of estimation for the IRT ability parameter. The…

  20. Physiological, physical and on-ice performance criteria for selection of elite ice hockey teams

    Directory of Open Access Journals (Sweden)

    R Roczniok

    2016-01-01

    Full Text Available The purpose of this study was to examine physiological and physical determinants of ice-hockey performance in order to assess their impact on the result during a selection for ice hockey. A total of 42 ice hockey players took part in the selection camp. At the end of the camp 20 best players were selected by team of expert coaches to the ice hockey team and created group G1, while the second group (G2 consisted of not selected players (non-successful group Evaluation of goodness of fit of the model to the data was based on the Hosmer Lemeshow test Ice hockey players selected to the team were taller 181.95±4.02 cm, had lower % body fat 13.17±3.17%, a shorter time to peak power 2.47±0.35 s , higher relative peak power 21.34±2.41 W • kg-1 and higher relative total work 305.18±28.41 J • kg-1. The results of the aerobic capacity test showed significant differences only in case of two variables. Ice hockey players in the G1 had higher VO2max 4.07±0.31 l • min-1 values than players in the G2 as well as ice hockey players in G1 showed a higher level of relative VO2max 51.75±2.99 ml • min-1 • kg-1 than athletes in G2. Ice hockey players selected to the team (G1 performed better in the 30 m Forwards Sprint 4.28±0.31 s; 6x9 Turns 12.19±0.75 s; 6x9 stops 12.79±0.49 s and Endurance test (6x30 m stops 32.01±0.80 s than players in G2. The logistic regression model showed that the best predictors of success in the recruitment process of top level ice hockey players were time to peak power, relative peak power, VO2max and 30 m sprint forwards on ice. On the basis of the constructed predictive logistic regression model it will be possible to determine the probability of success of the athletes during following the selection processes to the team.

  1. Human reliability

    International Nuclear Information System (INIS)

    Embrey, D.E.

    1987-01-01

    Concepts and techniques of human reliability have been developed and are used mostly in probabilistic risk assessment. For this, the major application of human reliability assessment has been to identify the human errors which have a significant effect on the overall safety of the system and to quantify the probability of their occurrence. Some of the major issues within human reliability studies are reviewed and it is shown how these are applied to the assessment of human failures in systems. This is done under the following headings; models of human performance used in human reliability assessment, the nature of human error, classification of errors in man-machine systems, practical aspects, human reliability modelling in complex situations, quantification and examination of human reliability, judgement based approaches, holistic techniques and decision analytic approaches. (UK)

  2. Reliability Calculations

    DEFF Research Database (Denmark)

    Petersen, Kurt Erling

    1986-01-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety...... and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic...... approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very...

  3. Performance Criteria for Capture and/or Immobilization Technologies - Milestone Report

    Energy Technology Data Exchange (ETDEWEB)

    Bruffey, Stephanie H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jubin, Robert Thomas [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Spencer, Barry B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Soelberg, Nick [Idaho National Lab. (INL), Idaho Falls, ID (United States); Riley, Brian [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-01

    The capture and subsequent immobilization of the four regulated volatile radionuclides (3H, 14C, 85Kr, and 129I) from the off-gas streams of a used nuclear fuel (UNF) reprocessing facility has been a topic of substantial research interest for the US Department of Energy and its international colleagues. Removal of some or all of these radionuclides (e.g., based upon fuel burnup, fuel type, cooling time) from the plant effluent streams prior to discharge to the environment is required to meet regulations set forth by the US Environmental Protection Agency. Upon removal, the radionuclide, as well as associated sorbents that cannot be cost-effectively regenerated, is destined for conversion to a waste form. Research in separation and capture methodologies has included a wide range of technologies, including liquid caustic scrubbing systems, solid adsorbents, and cryogenic distillation. The studies of waste forms have been correspondingly diverse. In considering the technologies available for future development and implementation of both sorbents and waste forms, it is necessary to identify benchmark measures of performance to evaluate objectively each sorbent system or waste form.

  4. An Integrated Multi-Criteria Decision Making Model for Evaluating Wind Farm Performance

    Directory of Open Access Journals (Sweden)

    Mei-Sung Kang

    2011-11-01

    Full Text Available The demands for alternative energy resources have been increasing exponentially in the 21st century due to continuous industrial development, depletion of fossil fuels and emerging environmental consciousness. Renewable energy sources, including wind energy, hydropower energy, geothermal energy, solar energy, biomass energy and ocean power, have received increasing attention as alternative means of meeting global energy demands. After Japan's Fukushima nuclear plant disaster in March 2011, more and more countries are having doubt about the safety of nuclear plants. As a result, safe and renewable energy sources are attracting even more attention these days. Wind energy production, with its relatively safer and positive environmental characteristics, has evolved in the past few decades from a marginal activity into a multi-billion dollar industry. In this research, a comprehensive evaluation model is constructed to select a suitable location for developing a wind farm. The model incorporates interpretive structural modeling (ISM, benefits, opportunities, costs and risks (BOCR and fuzzy analytic network process (FANP. Experts in the field are invited to contribute their expertise in evaluating the importance of the factors and various aspects of the wind farm evaluation problem, and the most suitable wind farm can finally be generated from the model. A case study is carried out in Taiwan in evaluating the expected performance of several potential wind farms, and a recommendation is provided for selecting the most appropriate wind farm for construction.

  5. Performance evaluation of hybrid VLC using device cost and power over data throughput criteria

    Science.gov (United States)

    Lee, C. C.; Tan, C. S.; Wong, H. Y.; Yahya, M. B.

    2013-09-01

    Visible light communication (VLC) technology has attained its attention in both academic and industry lately. It is determined by the development of light emitting diode (LED) technology for solid-state lighting (SSL).It has great potential to gradually replace radio frequency (RF) wireless technology because it offers unregulated and unlicensed bandwidth to withstand future demand of indoor wireless access to real-time bandwidth-demanding applications. However, it was found to provide intrusive uplink channel that give rise to unpleasant irradiance from the user device which could interfere with the downlink channel of VLC and hence limit mobility to users as a result of small coverage (field of view of VLC).To address this potential problem, a Hybrid VLC system which integrates VLC (for downlink) and RF (for uplink) technology is proposed. It offers a non-intrusive RF back channel that provides high throughput VLC and maintains durability with conventional RF devices. To deploy Hybrid VLC system in the market, it must be energy and cost saving to attain its equivalent economical advantage by comparing to existing architecture that employs fluorescent or LED lights with RF technology. In this paper, performance evaluation on the proposed hybrid system was carried out in terms of device cost and power consumption against data throughput. Based on our simulation, Hybrid VLC system was found to reduce device cost by 3% and power consumption by 68% when compares to fluorescent lights with RF technology. Nevertheless, when it is compared to LED lights with RF technology, our proposed hybrid system is found to achieve device cost saving as high as 47% and reduced power consumption by 49%. Such promising results have demonstrated that Hybrid VLC system is a feasible solution and has paved the way for greater cost saving and energy efficient compares with the current RF architecture even with the increasing requirement of indoor area coverage.

  6. Intra-rater reliability and agreement of muscle strength, power and functional performance measures in patients with hip osteoarthritis

    DEFF Research Database (Denmark)

    Bieler, Theresa; Magnusson, S Peter; Kjær, Michael

    2014-01-01

    OBJECTIVE: To investigate the reliability and agreement of measures of lower extremity muscle strength, power and functional performance in patients with hip osteoarthritis at different time intervals, and to compare these with the same measures in healthy peers. DESIGN: Intra-rater test...... extensor power, and functional performance (8-foot Up & Go, stair climbing, chair stand and 6-min walk) were measured in patients, and quadriceps strength, leg extensor power and functional performance were measured in healthy peers. Systematic error, reliability and agreement were calculated. RESULTS......-retest separated by 1, 2, or 2.5 weeks in patients, and 1 week in healthy peers. SUBJECTS: Patients with hip osteoarthritis (age range 61-83 years) with 1 (n = 37), 2 (n = 35), or 2.5 weeks (n = 15) between tests, and 35 healthy peers (age range 63-82 years). METHODS: Maximal isometric hip and thigh strength, leg...

  7. The Functional Test for Agility Performance is a Reliable Quick Decision-Making Test for Skilled Water Polo Players

    Directory of Open Access Journals (Sweden)

    Tucher Guilherme

    2015-06-01

    Full Text Available The reliability of the Functional Test for Agility Performance has only been evaluated in water polo players in a small group of novice athletes. Thus, the aim of this study was to evaluate the reliability of the Functional Test for Agility Performance in skilled water polo players. Forty-two athletes (17.81 ± 3.24 years old with a minimum of 5 years of competitive experience (7.05 ± 2.84 years and playing at the national or international level were evaluated. The Functional Test for Agility Performance is characterized as a specific open decision-making test where a tested player moves as quickly as possible in accordance to a pass made by another player. The time spent in the test was measured by two experienced coaches. Descriptive statistics, repeated measures analysis of variance (ANOVA, 95% limit of agreement (LOA, intraclass correlation coefficient (ICC and standard error of measurements (SEM were used for data analysis. Athletes completed the Functional Test for Agility Performance in 4.15 0.47 s. The ICC value was 0.87 (95% IC = 0.80-0.92. The SEM varied between 0.24 and 0.38 s. The LOA was 1.20 s and the CV average considering each individual trial was 6%. The Functional Test for Agility Performance was shown to be a reliable quick decision-making test for skilled water polo players.

  8. Reliability and validity of videotaped functional performance tests in ACL-injured subjects

    DEFF Research Database (Denmark)

    von Porat, Anette; Holmström, Eva; Roos, Ewa

    2008-01-01

    BACKGROUND AND PURPOSE: In clinical practice, visual observation is often used to determine functional impairment and to evaluate treatment following a knee injury. The aim of this study was to evaluate the reliability and validity of observational assessments of knee movement pattern quality......, crossover hop on one leg and one-leg hop. The videos were observed by four physiotherapists, and the knee movement pattern quality, a feature of the loading strategy of the lower extremity, was scored on an 11-point rating scale. To assess the criterion validity, the observational rating was correlated...... obtained between the observers' assessment and knee flexion angle, r = 0.37-0.61. The crossover hop test or one-leg hop test was ranked as the most useful test in 172 of 192 occasions (90%) when assessing knee function. CONCLUSION: The moderate to good inter-observer reliability and the moderate criterion...

  9. Applying the High Reliability Health Care Maturity Model to Assess Hospital Performance: A VA Case Study.

    Science.gov (United States)

    Sullivan, Jennifer L; Rivard, Peter E; Shin, Marlena H; Rosen, Amy K

    2016-09-01

    The lack of a tool for categorizing and differentiating hospitals according to their high reliability organization (HRO)-related characteristics has hindered progress toward implementing and sustaining evidence-based HRO practices. Hospitals would benefit both from an understanding of the organizational characteristics that support HRO practices and from knowledge about the steps necessary to achieve HRO status to reduce the risk of harm and improve outcomes. The High Reliability Health Care Maturity (HRHCM) model, a model for health care organizations' achievement of high reliability with zero patient harm, incorporates three major domains critical for promoting HROs-Leadership, Safety Culture, and Robust Process Improvement ®. A study was conducted to examine the content validity of the HRHCM model and evaluate whether it can differentiate hospitals' maturity levels for each of the model's components. Staff perceptions of patient safety at six US Department of Veterans Affairs (VA) hospitals were examined to determine whether all 14 HRHCM components were present and to characterize each hospital's level of organizational maturity. Twelve of the 14 components from the HRHCM model were detected; two additional characteristics emerged that are present in the HRO literature but not represented in the model-teamwork culture and system-focused tools for learning and improvement. Each hospital's level of organizational maturity could be characterized for 9 of the 14 components. The findings suggest the HRHCM model has good content validity and that there is differentiation between hospitals on model components. Additional research is needed to understand how these components can be used to build the infrastructure necessary for reaching high reliability.

  10. The Impact of Automation Reliability and Operator Fatigue on Performance and Reliance

    Science.gov (United States)

    2016-09-23

    Cummings et al., 2007). Automation designed to assist operators in overload situations may promote operator disengagement during periods of low...Calhoun et al., 2011). This testbed offers several tasks designed to emulate the cognitive demands that an operator managing multiple UAVs is likely...reliable (Cronbach’s α = 0.94) measure of affective and cognitive components of trust in automation. Items gauge confidence in an automation and

  11. THERMAL AND THERMO-MECHANICAL CHARACTERISTICS OF CRYOGENIC MICROCOOLER FOR OPTIMUM PERFORMANCE AND RELIABILITY

    Science.gov (United States)

    2017-10-19

    reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of...contracted fundamental research deemed exempt from public affairs security and policy review in accordance with SAF/AQR memorandum dated 10 Dec 08 and AFRL...subjected to cryogenic operating conditions was assessed by proposing a hierarchical physics -of-failure-based reliability assessment model. 15. SUBJECT

  12. Application of a Genetic Algorithm to the Optimization of a Missile Autopilot Controller for Performance Criteria with Non-Analytic Solutions

    National Research Council Canada - National Science Library

    Hull, Richard

    1993-01-01

    .... Genetic algorithms (GA's), on the other hand, offer a numerical search method which does not require a statement of the mathematical relationship between the performance criteria and the parameter update rule...

  13. Performance characteristics and parametric optimum criteria of a Brownian micro-refrigerator in a spatially periodic temperature field

    International Nuclear Information System (INIS)

    Lin Bihong; Chen Jincan

    2009-01-01

    It is shown that a microscopic system consisting of Brownian particles moving in a spatially asymmetric but periodic potential (ratchet) and contacting with the alternating hot and cold reservoirs along space coordinate and an external force applying on the particles may work as a refrigerator. In order to clarify the underlying physical pictures of the system, the heat flows via both the potential energy and the kinetic energy of the particles are considered simultaneously. Based on an Arrhenius' factor describing the forward and backward particle currents, expressions for some important performance parameters of the refrigerator, such as the coefficient of performance, cooling rate and power input, are derived analytically. The maximum coefficient of performance and cooling rate are numerically calculated for some given parameters. The influence of the main parameters such as the external force, barrier height of the potential, asymmetry of the potential and temperature ratio of the heat reservoirs on the performance of the Brownian refrigerator is discussed. The optimum criteria of some characteristic parameters are given. It is found that the Brownian refrigerator may be controlled to operate in different regions through the choice of several parameters

  14. Microwave induced plasma for solid fuels and waste processing: A review on affecting factors and performance criteria.

    Science.gov (United States)

    Ho, Guan Sem; Faizal, Hasan Mohd; Ani, Farid Nasir

    2017-11-01

    High temperature thermal plasma has a major drawback which consumes high energy. Therefore, non-thermal plasma which uses comparatively lower energy, for instance, microwave plasma is more attractive to be applied in gasification process. Microwave-induced plasma gasification also carries the advantages in terms of simplicity, compactness, lightweight, uniform heating and the ability to operate under atmospheric pressure that gains attention from researchers. The present paper synthesizes the current knowledge available for microwave plasma gasification on solid fuels and waste, specifically on affecting parameters and their performance. The review starts with a brief outline on microwave plasma setup in general, and followed by the effect of various operating parameters on resulting output. Operating parameters including fuel characteristics, fuel injection position, microwave power, addition of steam, oxygen/fuel ratio and plasma working gas flow rate are discussed along with several performance criteria such as resulting syngas composition, efficiency, carbon conversion, and hydrogen production rate. Based on the present review, fuel retention time is found to be the key parameter that influences the gasification performance. Therefore, emphasis on retention time is necessary in order to improve the performance of microwave plasma gasification of solid fuels and wastes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Analyzing Reliability and Performance Trade-Offs of HLS-Based Designs in SRAM-Based FPGAs Under Soft Errors

    Science.gov (United States)

    Tambara, Lucas Antunes; Tonfat, Jorge; Santos, André; Kastensmidt, Fernanda Lima; Medina, Nilberto H.; Added, Nemitala; Aguiar, Vitor A. P.; Aguirre, Fernando; Silveira, Marcilei A. G.

    2017-02-01

    The increasing system complexity of FPGA-based hardware designs and shortening of time-to-market have motivated the adoption of new designing methodologies focused on addressing the current need for high-performance circuits. High-Level Synthesis (HLS) tools can generate Register Transfer Level (RTL) designs from high-level software programming languages. These tools have evolved significantly in recent years, providing optimized RTL designs, which can serve the needs of safety-critical applications that require both high performance and high reliability levels. However, a reliability evaluation of HLS-based designs under soft errors has not yet been presented. In this work, the trade-offs of different HLS-based designs in terms of reliability, resource utilization, and performance are investigated by analyzing their behavior under soft errors and comparing them to a standard processor-based implementation in an SRAM-based FPGA. Results obtained from fault injection campaigns and radiation experiments show that it is possible to increase the performance of a processor-based system up to 5,000 times by changing its architecture with a small impact in the cross section (increasing up to 8 times), and still increasing the Mean Workload Between Failures (MWBF) of the system.

  16. A fuzzy multi criteria approach for measuring sustainability performance of a supplier based on triple bottom line approach

    DEFF Research Database (Denmark)

    Govindan, Kannan; Khodaverdi, R.; Jafarian, A.

    2013-01-01

    responsibility. Sustainable supply chain initiatives like supplier environmental and social collaboration can play a significant role in achieving the "triple bottom line" of social, environmental, and economic benefits. Supplier selection plays an important role in the management of a supply chain......Sustainable supply chain management has received much attention from practitioners and scholars over the past decade owing to the significant attention given by consumers, profit and not-for-profit organizations, local communities, legislation and regulation to environmental, social and corporate....... Traditionally, organizations consider criteria such as price, quality, flexibility, etc. when evaluating supplier performance. While the articles on the selection and evaluation of suppliers are abundant, those that consider sustainability issues are rather limited. This paper explores sustainable supply chain...

  17. Attentional and visual demands for sprint performance in non-fatigued and fatigued conditions: reliability of a repeated sprint test

    Directory of Open Access Journals (Sweden)

    Diercks Ron L

    2010-05-01

    Full Text Available Abstract Background Physical performance measures are widely used to assess physical function, providing information about physiological and biomechanical aspects of motor performance. However they do not provide insight into the attentional and visual demands for motor performance. A figure-of-eight sprint test was therefore developed to measure the attentional and visual demands for repeated-sprint performance. The aims of the study were: 1 to assess test-retest reliability of the figure-of-eight sprint test, and 2 to study the attentional and visual demands for sprint performance in a non-fatigued and fatigued condition. Methods Twenty-seven healthy athletes were included in the study. To determine test-retest reliability, a subgroup of 19 athletes performed the figure-of-eight sprint test twice. The figure-of-eight sprint test consisted of nine 30-second sprints. The sprint test consisted of three test parts: sprinting without any restriction, with an attention-demanding task, and with restricted vision. Increases in sprint times with the attention-demanding task or restricted vision are reflective of the attentional and visual demands for sprinting. Intraclass correlation coefficients (ICCs and mean difference between test and retest with 95% confidence limits (CL were used to assess test-retest reliability. Repeated-measures ANOVA were used for comparisons between the sprint times and fatigue measurements of the test parts in both a non-fatigued and fatigued condition. Results The figure-of-eight sprint test showed good test-retest reliability, with ICCs ranging from 0.75 to 0.94 (95% CL: 0.40-0.98. Zero lay within the 95% CL of the mean differences, indicating that no bias existed between sprint performance at test and retest. Sprint times during the test parts with attention-demanding task (P = 0.01 and restricted vision (P Conclusions High ICCs and the absence of systematic variation indicate good test-retest reliability of the figure

  18. KETERKAITAN KATEGORI KEPEMIMPINAN DENGAN ENAM KATEGORI LAINNYA DALAM MALCOLM BALDRIGE CRITERIA FOR PERFORMANCE EXCELLENCE (MBCFPE PADA BADAN USAHA MILIK NEGARA

    Directory of Open Access Journals (Sweden)

    Rudjito Rudjito

    2011-08-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 Some State Own Enterprises (SOEs have measured their performance based on Malcolm Baldrige Criteria for Performance Excellence method yearly since 2005 and participated in Indonesia Quality Award (IQA to recognize their performances. The MBCfPE method measures company performance based on seven criterion categories, which Leadership as the first category is stated in the method that must be visionary, motivator and as the driver to lead people and entire organization to achieve performance excellence. The purposes of this study is to analyze the interrelatation of Leadership as first category to category second up to category seventh of MBCfPE.Convenience and purposive (judgmental sampling techniques are used to choose twelve SOEs, which consist of two groups of six SOEs: “Good Performance” and “Below Good Performance”. Two hundred seventy two respondents consist of SOEs’ CEO, management and employees who understand MBCfPE method have participated in this study which selected by judgmental sampling technique. Reseacher used Rank Spearman and Discriminant anlysis for analyzing the interrelation of leadership category to category second up to seventh of MBCfPE. According to rank-spearman correlation analysis results, in overall, most of variables X (areas to address of Laedership category, have relation with variables Y (areas to address of category second up category seventh of MBCfPE, except for variable X4 (Legal and ethical behavior and variable X5 (Societal Responsibility and Support of key communities to variable Y1 (Strategy development process. From Discriminant analysis, it can be concluded that Communication and Company Performance is variable that discriminate between SOEs “Good Performance” and SOEs “Below Good Performance”.

  19. Performance, compliance and reliability of Waste stabilization pond: Effluent discharge quality and environmental protection agency standards in Ghana

    DEFF Research Database (Denmark)

    Owusu-Ansah, Emmanuel de-Graft Johnson; Sampson, Angelina; Amponsah, Samuel K.

    2015-01-01

    function to establish the relationship between the statistical coefficient of variation and the coefficient of reliability based on rth moment about the origin in the moment of generation function to generate the functions of the mean and standard deviation, properties of the standard Z normal distribution...... were used to establish the coefficient of reliability relationship depending on the coefficient of variation influenced by the standard of deviation. Discharge values of Physico-chemical Parameters measured from the WSP were found be performing acceptably based on the EPA standards, whereas only four......Measuring performance has been arguerably, one of the metric with many facets with different school of thoughts, as there exist different approaches of measuring it. Several of the existing approaches measure such metric by comparison with standards esherined in policy documents and as a result...

  20. Effect of Sensors on the Reliability and Control Performance of Power Circuits in the Web of Things (WoT

    Directory of Open Access Journals (Sweden)

    Sungwoo Bae

    2016-09-01

    Full Text Available In order to realize a true WoT environment, a reliable power circuit is required to ensure interconnections among a range of WoT devices. This paper presents research on sensors and their effects on the reliability and response characteristics of power circuits in WoT devices. The presented research can be used in various power circuit applications, such as energy harvesting interfaces, photovoltaic systems, and battery management systems for the WoT devices. As power circuits rely on the feedback from voltage/current sensors, the system performance is likely to be affected by the sensor failure rates, sensor dynamic characteristics, and their interface circuits. This study investigated how the operational availability of the power circuits is affected by the sensor failure rates by performing a quantitative reliability analysis. In the analysis process, this paper also includes the effects of various reconstruction and estimation techniques used in power processing circuits (e.g., energy harvesting circuits and photovoltaic systems. This paper also reports how the transient control performance of power circuits is affected by sensor interface circuits. With the frequency domain stability analysis and circuit simulation, it was verified that the interface circuit dynamics may affect the transient response characteristics of power circuits. The verification results in this paper showed that the reliability and control performance of the power circuits can be affected by the sensor types, fault tolerant approaches against sensor failures, and the response characteristics of the sensor interfaces. The analysis results were also verified by experiments using a power circuit prototype.

  1. "Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia".

    Science.gov (United States)

    Olsen, Cecilie Fromholt; Bergland, Astrid

    2017-06-09

    The purpose of the study was to establish the test-retest reliability of the Norwegian version of the Short Physical Performance Battery (SPPB). This was a cross- sectional reliability study. A convenience sample of 61 older adults with a mean age of 88.4(8.1) was tested by two different physiotherapists at two time points. The mean time interval between tests was 2.5 days. The Intraclass Correlation Coefficient model 3.1 (ICC, 3.1) with 95% confidence intervals as well as the weighted Kappa (K) were used as measures of relative reliability. The Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC) were used to measure absolute reliability. The results were also analyzed for a subgroup of 24 older people with dementia. The ICC reflected high relative reliability for the SPPB summary score and the 4 m walk test (4mwt), both for the total sample (ICC = 0.92, and 0.91 respectively)) and for the subgroup with dementia (ICC = 0.84 and 0.90 respectively). Furthermore, weighted Ks for the SPPB subscales were 0.64 for the chair stand, 0.80 for gait and 0.52 for balance for the total sample and almost identical for the subgroup with dementia. MDC-values at the 95% confidence intervals (MDC95) were calculated at 0.8 for the total score of SPPB and 0.39 m/s for the 4mwt in the total sample. For the subgroup with dementia MDC95 was 1.88 for the total score of SPPB and 0.28 m/s for 4mwt. The SPPB total score and the timed walking test showed overall high relative and absolute reliability for the total sample indicating that the Norwegian version of the SPPB is reliable when used by trained physiotherapists with older people. The reliability of the Norwegian SPPB in older people with dementia seems high, but due to a small sample size this needs further investigation.

  2. Ball-Sport Endurance and Sprint Test (BEAST90): validity and reliability of a 90-minute soccer performance test.

    Science.gov (United States)

    Williams, Jeremy D; Abt, Grant; Kilding, Andrew E

    2010-12-01

    The aim of this study was to determine the validity and reliability of a 90-minute soccer performance test: Ball-sport Endurance and Sprint Test (BEAST90). Fifteen healthy male amateur soccer players participated and attended 5 testing sessions over a 10-day period to perform physiologic and soccer-specific assessments. This included familiarization sessions and 2 full trials of the BEAST90, separated by 7 days. The total 90-minute distance, mean percent peak heart rate (HRpeak), and estimated percent peak oxygen uptake of the BEAST90 were 8,097 ± 458 m, 85 ± 5% and 82 ± 14%, respectively. Measures obtained from trial 1 and trial 2 were not significantly different (p > 0.05). Reliability of measures over 90 minutes ranged from 0.9-25.5% (% typical error). The BEAST90 protocol replicated soccer match play in terms of time, movement patterns, physical demands (volume and intensity), distances, and mean and HRpeak values, as well as having an aerobic load similar to that observed during a soccer match. Reproducibility of key physical measures during the BEAST90 were mostly high, suggesting good reliability. The BEAST90 could be used in studies that wish to determine the effects of training or nutritional interventions on prolonged intermittent physical performance.

  3. Performance and Benchmarking of Multisurface UHF RFID Tags for Readability and Reliability

    Directory of Open Access Journals (Sweden)

    Joshua Bolton

    2017-01-01

    Full Text Available As the price of passive radio frequency identification (RFID tags continues to decrease, more and more companies are considering item-level tagging. Although the use of RFID is simple, its proper application should be studied to achieve maximum efficiency and utilization in the industry. This paper is intended to demonstrate the test results of various multisurface UHF tags from different manufacturers for their readability under varying conditions such as orientation of tags with respect to reader, distance of tag from the reader, and materials used for embedding tags. These conditions could affect the reliability of RFID systems used for varied applications. In this paper, we implement a Design for Six Sigma Research (DFSS-R methodology that allows for reliability testing of RFID systems. In this paper, we have showcased our results about the benchmarking of UHF RFID tags and have put forward an important observation about the blind spots observed at different distances and orientations along different surfaces, which is primarily due to the polarity of the antenna chosen.

  4. Reliability analysis of repairable multi-state system with common bus performance sharing

    International Nuclear Information System (INIS)

    Yu, Huan; Yang, Jun; Mo, Huadong

    2014-01-01

    In this paper, an instantaneous availability model for repairable multi-state system (MSS) with common bus performance sharing is proposed. The repairable MSS consists of some multi-state units and a common bus performance redistribution system. Each unit in the system has several performance levels and must satisfy its individual random demand. A unit can transmit the surplus performance to other units in real time through the common bus performance redistribution system, if it has a performance that exceeds its demand. The entire system fails if the demand of any unit is not satisfied. A new method based on the combination of the stochastic process method and the universal generating function technique is suggested to evaluate the instantaneous availability and the mean instantaneous performance deficiency of the proposed repairable MSS. Two examples are given for applications in the end

  5. Reliability Engineering

    CERN Document Server

    Lazzaroni, Massimo

    2012-01-01

    This book gives a practical guide for designers and users in Information and Communication Technology context. In particular, in the first Section, the definition of the fundamental terms according to the international standards are given. Then, some theoretical concepts and reliability models are presented in Chapters 2 and 3: the aim is to evaluate performance for components and systems and reliability growth. Chapter 4, by introducing the laboratory tests, puts in evidence the reliability concept from the experimental point of view. In ICT context, the failure rate for a given system can be

  6. Performance and Reliability of Bonded Interfaces for High-Temperature Packaging

    Energy Technology Data Exchange (ETDEWEB)

    Paret, Paul P [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-02

    Sintered silver has proven to be a promising candidate for use as a die-attach and substrate-attach material in automotive power electronics components. It holds promise of greater reliability than lead-based and lead-free solders, especially at higher temperatures (>200 degrees C). Accurate predictive lifetime models of sintered silver need to be developed and its failure mechanisms thoroughly characterized before it can be deployed as a die-attach or substrate-attach material in wide-bandgap device-based packages. Mechanical characterization tests that result in stress-strain curves and accelerated tests that produce cycles-to-failure result will be conducted. Also, we present a finite element method (FEM) modeling methodology that can offer greater accuracy in predicting the failure of sintered silver under accelerated thermal cycling. A fracture mechanics-based approach is adopted in the FEM model, and J-integral/thermal cycle values are computed.

  7. Review of the human reliability analysis performed for Empire State Electric Energy Research Corporation

    International Nuclear Information System (INIS)

    Swart, D.; Banz, I.

    1985-01-01

    The Empire State Electric Energy Research Corporation (ESEERCO) commissioned Westinghouse to conduct a human reliability analysis to identify and quantify human error probabilities associated with operator actions for four specific events which may occur in light water reactors: loss of coolant accident, steam generator tube rupture, steam/feed line break, and stuck open pressurizer spray valve. Human Error Probabilities (HEPs) derived from Swain's Technique for Human Error Rate Prediction (THERP) were compared to data obtained from simulator exercises. A correlation was found between the HEPs derived from Swain and the results of the simulator data. The results of this study provide a unique insight into human factors analysis. The HEPs obtained from such probabilistic studies can be used to prioritize scenarios for operator training situations, and thus improve the correlation between simulator exercises and real control room experiences

  8. Demands placed on waste package performance testing and modeling by some general results on reliability analysis

    International Nuclear Information System (INIS)

    Chesnut, D.A.

    1991-09-01

    Waste packages for a US nuclear waste repository are required to provide reasonable assurance of maintaining substantially complete containment of radionuclides for 300 to 1000 years after closure. The waiting time to failure for complex failure processes affecting engineered or manufactured systems is often found to be an exponentially-distributed random variable. Assuming that this simple distribution can be used to describe the behavior of a hypothetical single barrier waste package, calculations presented in this paper show that the mean time to failure (the only parameter needed to completely specify an exponential distribution) would have to be more than 10 7 years in order to provide reasonable assurance of meeting this requirement. With two independent barriers, each would need to have a mean time to failure of only 10 5 years to provide the same reliability. Other examples illustrate how multiple barriers can provide a strategy for not only achieving but demonstrating regulatory compliance

  9. Performance characteristics of seven bilevel mechanical ventilators in pressure-support mode with different cycling criteria: a comparative bench study.

    Science.gov (United States)

    Chen, Yuqing; Cheng, Kewen; Zhou, Xin

    2015-01-26

    Pressure support ventilation from a bilevel device is a standard technique for non-invasive home ventilation. A bench study was designed to compare the performance and patient-ventilator synchronization of 7 bilevel ventilators, in the presence of system leaks. Ventilators were connected to a Hans Rudolph Series 1101 lung simulator (compliance, 50 mL/cmH2O; expiratory resistance, 20 cmH2O/L/s; respiratory rate, 15 breaths/min; inspiratory time, 1.0 s). All ventilators were set at 15 cmH2O pressure support and 5 cmH2O positive end-expiratory pressure. Tests were conducted at 2 system leaks (12-15 and 25-28 L/min). The performance characteristics and patient-ventilator asynchrony were assessed, including flow, airway pressure, time, and workload. The Breas Vivo30 could not synchronize with the simulator (frequent auto-triggering) at a leak of 25-28 L/min, but provided stable assisted ventilation when the leak was 12-15 L/min. Missed efforts and back-up ventilation occurred for the Weinmann VENTImotion and Airox Smartair Plus, requiring adjustment of trigger effort. All ventilators had a short trigger delay time (ventilators, possibly due to software algorithm differences. Adjusting the cycling criteria settings can alter the shape of the inspiratory phase and peak expiratory flow, and improve patient-ventilator synchrony.

  10. The reliability of language performance measurement in language sample analysis of children aged 5-6 years

    Directory of Open Access Journals (Sweden)

    Zahra Soleymani

    2014-04-01

    Full Text Available Background and Aim: The language sample analysis (LSA is more common in other languages than Persian to study language development and assess language pathology. We studied some psychometric properties of language sample analysis in this research such as content validity of written story and its pictures, test-retest reliability, and inter-rater reliability.Methods: We wrote a story based on Persian culture from Schneider’s study. The validity of written story and drawn pictures was approved by experts. To study test-retest reliability, 30 children looked at the pictures and told their own story twice with 7-10 days interval. Children generated the story themselves and tester did not give any cue about the story. Their audio-taped story was transcribed and analyzed. Sentence and word structures were detected in the analysis.Results: Mean of experts' agreement with the validity of written story was 92.28 percent. Experts scored the quality of pictures high and excellent. There was correlation between variables in sentence and word structure (p<0.05 in test-retest, except complex sentences (p=0.137. The agreement rate was 97.1 percent in inter-rater reliability assessment of transcription. The results of inter-rater reliability of language analysis showed that correlation coefficients were significant.Conclusion: The results confirmed that the tool was valid for eliciting language sample. The consistency of language performance in repeated measurement varied from mild to high in language sample analysis approach.

  11. Reliability engineering

    International Nuclear Information System (INIS)

    Lee, Chi Woo; Kim, Sun Jin; Lee, Seung Woo; Jeong, Sang Yeong

    1993-08-01

    This book start what is reliability? such as origin of reliability problems, definition of reliability and reliability and use of reliability. It also deals with probability and calculation of reliability, reliability function and failure rate, probability distribution of reliability, assumption of MTBF, process of probability distribution, down time, maintainability and availability, break down maintenance and preventive maintenance design of reliability, design of reliability for prediction and statistics, reliability test, reliability data and design and management of reliability.

  12. A Malay version of the Child Oral Impacts on Daily Performances (Child-OIDP index: assessing validity and reliability

    Directory of Open Access Journals (Sweden)

    Yusof Zamros YM

    2012-06-01

    Full Text Available Abstract Background The study aimed to develop and test a Malay version of the Child-OIDP index, evaluate its psychometric properties and report on the prevalence of oral impacts on eight daily performances in a sample of 11–12 year old Malaysian schoolchildren. Methods The Child-OIDP index was translated from English into Malay. The Malay version was tested for reliability and validity on a non-random sample of 132, 11–12 year old schoolchildren from two urban schools in Kuala Lumpur. Psychometric analysis of the Malay Child-OIDP involved face, content, criterion and construct validity tests as well as internal and test-retest reliability. Non-parametric statistical methods were used to assess relationships between Child-OIDP scores and other subjective outcome measures. Results The standardised Cronbach’s alpha was 0.80 and the weighted Kappa was 0.84 (intraclass correlation = 0.79. The index showed significant associations with different subjective measures viz. perceived satisfaction with mouth, perceived needs for dental treatment, perceived oral health status and toothache experience in the previous 3 months (p  Conclusion This study indicated that the Malay Child-OIDP index is a valid and reliable instrument to measure the oral impacts of daily performances in 11–12 year old urban schoolchildren in Malaysia.

  13. Radiation protection - Performance criteria for laboratories performing cytogenetic triage for assessment of mass casualties in radiological or nuclear emergencies - General principles and application to dicentric assay

    International Nuclear Information System (INIS)

    2008-01-01

    The potential for nuclear and radiological emergencies involving mass casualties from accidental or malicious acts or terrorism requires generic procedures for emergency dose assessment to help the development of medical response capabilities. A mass-casualties incident is defined here as an event that exceeds the local medical resources. Biological dosimetry, based on cytogenetic analysis using the dicentric assay, typically applied for accidental dose assessment, has been defined in ISO 19238. Cytogenetic triage is the use of chromosome damage to evaluate and assess approximately and rapidly radiation doses received by individuals in order to supplement the clinical categorization of casualties. This International Standard focuses on the use of the dicentric assay for rapid cytogenetic triage involving mass-casualty incidents. The primary purpose of this International Standard is to provide a guideline to all laboratories in order to perform the dicentric-bioassay - cytogenetic triage for dose assessment using documented and validated procedures. Secondly, it can facilitate the application of cytogenetic biodosimetry networks to permit comparison of results obtained in different laboratories. Finally, it is expected that laboratories newly commissioned to carry out the cytogenetic triage conform to this International Standard in order to perform the triage reproducibly and accurately. This International Standard is written in the form of procedures to adopt for dicentric-bioassay - cytogenetic triage biological dosimetry for overexposures involving mass radiological casualties. The criteria required for such measurements usually depend on the application of the results: medical management when appropriate, radiation-protection management, record keeping and medical/legal requirements. For example, selected cases can be analysed to produce a more accurate evaluation of high partial-body exposure; secondly, doses can be estimated for persons exposed below the

  14. Use of performance shaping factors and quantified expert judgment in the evaluation of human reliability: an initial appraisal

    International Nuclear Information System (INIS)

    Embrey, D.E.

    1983-05-01

    The first part of the report considers the nature of human reliability assessment, and the techniques currently employed. It is concluded that most approaches are limited by the availability of data. Approaches to the subjective assessment of error are surveyed. A particular technique which has been developed, the Success Likelihood Index Methodology (SLIM), is described in detail, together with the practical steps for its implementation. The results from a trial application of a questionnaire designed to elicit judges' perceptions of the relative importance of performance shaping factors in determining human reliability are analyzed. A revised form of the questionnaire is presented for future use. A pilot experiment to investigate the relationship between subjectively derived indices of success for six tasks and their objective probability of success is described. The results indicate that the SLIM has potential value as a predictive technique. Some requirements for a program of research to produce a generally applicable methodology are set out

  15. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD

    Directory of Open Access Journals (Sweden)

    Formiga MF

    2018-05-01

    Full Text Available Magno F Formiga,1,2 Kathryn E Roach,1 Isabel Vital,3 Gisel Urdaneta,3 Kira Balestrini,3 Rafael A Calderon-Candelario,3,4 Michael A Campos,3,4,* Lawrence P Cahalin1,* 1Department of Physical Therapy, University of Miami Miller School of Medicine, Coral Gables, FL, USA; 2CAPES Foundation, Ministry of Education of Brazil, Brasilia, Brazil; 3Pulmonary Section, Miami Veterans Administration Medical Center, Miami, FL, USA; 4Division of Pulmonary, Allergy, Critical Care and Sleep Medicine, University of Miami Miller School of Medicine, Miami, FL, USA *These authors contributed equally to this work Purpose: The Test of Incremental Respiratory Endurance (TIRE provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP over time. The integration of MIP over inspiratory duration (ID provides the sustained maximal inspiratory pressure (SMIP. Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Patients and methods: Test–retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. Results: All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test–retest reliability with a nearly perfect intraclass correlation coefficient (ICC of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP

  16. The reliability of in-training assessment when performance improvement is taken into account

    NARCIS (Netherlands)

    van Lohuizen, M.T.; Kuks, J.B.; van Hell, E.A.; Raat, A.N.; Stewart, R.E.; Cohen-Schotanus, J.

    2010-01-01

    During in-training assessment students are frequently assessed over a longer period of time and therefore it can be expected that their performance will improve. We studied whether there really is a measurable performance improvement when students are assessed over an extended period of time and how

  17. Validity and reliability of global operative assessment of laparoscopic skills (GOALS) in novice trainees performing a laparoscopic cholecystectomy.

    Science.gov (United States)

    Kramp, Kelvin H; van Det, Marc J; Hoff, Christiaan; Lamme, Bas; Veeger, Nic J G M; Pierie, Jean-Pierre E N

    2015-01-01

    Global Operative Assessment of Laparoscopic Skills (GOALS) assessment has been designed to evaluate skills in laparoscopic surgery. A longitudinal blinded study of randomized video fragments was conducted to estimate the validity and reliability of GOALS in novice trainees. In total, 10 trainees each performed 6 consecutive laparoscopic cholecystectomies. Sixty procedures were recorded on video. Video fragments of (1) opening of the peritoneum; (2) dissection of Calot's triangle and achievement of critical view of safety; and (3) dissection of the gallbladder from the liver bed were blinded, randomized, and rated by 2 consultant surgeons using GOALS. Also, a grade was given for overall competence. The correlation of GOALS with live observation Objective Structured Assessment of Technical Skills (OSATS) scores was calculated. Construct validity was estimated using the Friedman 2-way analysis of variance by ranks and the Wilcoxon signed-rank test. The interrater reliability was calculated using the absolute and consistency agreement 2-way random-effects model intraclass correlation coefficient. A high correlation was found between mean GOALS score (r = 0.879, p = 0.021) and mean OSATS score. The GOALS score increased significantly across the 6 procedures (p = 0.002). The trainees performed significantly better on their sixth when compared with their first cholecystectomy (p = 0.004). The consistency agreement interrater reliability was 0.37 for the mean GOALS score (p = 0.002) and 0.55 for overall competence (p < 0.001) of the 3 video fragments. The validity observed in this randomized blinded longitudinal study supports the existing evidence that GOALS is a valid tool for assessment of novice trainees. A relatively low reliability was found in this study. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  18. U.S. Army Physical Demands Study: Reliability of Simulations of Physically Demanding Tasks Performed by Combat Arms Soldiers.

    Science.gov (United States)

    Foulis, Stephen A; Redmond, Jan E; Frykman, Peter N; Warr, Bradley J; Zambraski, Edward J; Sharp, Marilyn A

    2017-12-01

    Foulis, SA, Redmond, JE, Frykman, PN, Warr, BJ, Zambraski, EJ, and Sharp, MA. U.S. Army physical demands study: reliability of simulations of physically demanding tasks performed by combat arms soldiers. J Strength Cond Res 31(12): 3245-3252, 2017-Recently, the U.S. Army has mandated that soldiers must successfully complete the physically demanding tasks of their job to graduate from their Initial Military Training. Evaluating individual soldiers in the field is difficult; however, simulations of these tasks may aid in the assessment of soldiers' abilities. The purpose of this study was to determine the reliability of simulated physical soldiering tasks relevant to combat arms soldiers. Three cohorts of ∼50 soldiers repeated a subset of 8 simulated tasks 4 times over 2 weeks. Simulations included: sandbag carry, casualty drag, and casualty evacuation from a vehicle turret, move under direct fire, stow ammunition on a tank, load the main gun of a tank, transferring ammunition with a field artillery supply vehicle, and a 4-mile foot march. Reliability was assessed using intraclass correlation coefficients (ICCs), standard errors of measurement (SEMs), and 95% limits of agreement. Performance of the casualty drag and foot march did not improve across trials (p > 0.05), whereas improvements, suggestive of learning effects, were observed on the remaining 6 tasks (p ≤ 0.05). The ICCs ranged from 0.76 to 0.96, and the SEMs ranged from 3 to 16% of the mean. These 8 simulated tasks show high reliability. Given proper practice, they are suitable for evaluating the ability of Combat Arms Soldiers to complete the physical requirements of their jobs.

  19. Learning process for performing and analyzing 3D/4D transperineal ultrasound imaging and interobserver reliability study.

    Science.gov (United States)

    Siafarikas, F; Staer-Jensen, J; Braekken, I H; Bø, K; Engh, M Ellström

    2013-03-01

    To evaluate the learning process for acquiring three- and four-dimensional (3D/4D) transperineal ultrasound volumes of the levator hiatus (LH) dimensions at rest, during pelvic floor muscle (PFM) contraction and on Valsalva maneuver, and for analyzing the ultrasound volumes, as well as to perform an interobserver reliability study between two independent ultrasound examiners. This was a prospective study including 22 women. We monitored the learning process of an inexperienced examiner (IE) performing 3D/4D transperineal ultrasonography and analyzing the volumes. The examination included acquiring volumes during three PFM contractions and three Valsalva maneuvers. LH dimensions were determined in the axial plane. The learning process was documented by estimating agreement between the IE and an experienced examiner (E) using the intraclass correlation coefficient. Agreement was calculated in blocks of 10 ultrasound examinations and analyzed volumes. After the learning process was complete the interobserver reliability for the technique was calculated between these two independent examiners. For offline analysis of the first 10 ultrasound volumes obtained by E, good to very good agreement between E and IE was achieved for all LH measurements except for the left and right levator-urethra gap and pubic arc. For the next 10 analyzed volumes, agreement improved for all LH measurements. Volumes that had been obtained by IE and E were then re-evaluated by IE, and good to very good agreement was found for all LH measurements indicating consistency in volume acquisition. The interobserver reliability study showed excellent ICC values (ICC, 0.81-0.97) for all LH measurements except the pubic arc (ICC = 0.67). 3D/4D transperineal ultrasound is a reliable technique that can be learned in a short period of time. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  20. On the reliability of steam generator performance at nuclear power plants with WWER type reactors

    International Nuclear Information System (INIS)

    Styrikovich, M.A.; Margulova, T.Kh.

    1974-01-01

    The problem of ensuring reliable operation of steam generators in a nuclear power plant with a water-cooled, water-moderated reactor (WWER) was studied. At a nuclear power plant with a vertical steam generator (specifically, a Westinghouse product) the steam generator tubes were found to have been penetrated. Shutdown was due to corrosion disintegration of the austenitic stainless steel, type 18/8, used as pipe material for the heater surface. The corrosion was the result of the action of chlorine ions concentrated in the moisture contained in the iron oxide films deposited in low parts of the tube bundle, directly at the tube plate. Blowing through did not ensure complete removal of the film, and in some cases the construction features of the steam generator made removal of the film practically impossible. Replacement of type 18/8 stainless steel by other construction material, e.g., Inconel, did not give good results. To ensure reliable operation of vertical steam generators in domestic practice, the generators are designed without a low tube plate (a variant diagram of the vertical steam generator of such construction for the water-cooled, water-moderated reactor 1000 is presented). When low tube plates are used the film deposition is intolerable. For organization of a non-film regime a complex treatment of the feed water is used, in which the amount of complexion is calculated from the stoichmetric ratios with the composition of the feed water. It is noted that, if 100% condensate purification is used with complexon processing of the feed water to the generator, we can calculate the surface of the steam-generator heater without considering the outer placement on the tubes. In this the cost of the steam generator and all the nuclear power plants with WWER type reactors is decreased even with installation of a 100% condensate purification. It is concluded that only simultaneous solution of construction and water-regime problems will ensure relaible operation of

  1. Dataset size and composition impact the reliability of performance benchmarks for peptide-MHC binding predictions

    DEFF Research Database (Denmark)

    Kim, Yohan; Sidney, John; Buus, Søren

    2014-01-01

    Background: It is important to accurately determine the performance of peptide: MHC binding predictions, as this enables users to compare and choose between different prediction methods and provides estimates of the expected error rate. Two common approaches to determine prediction performance...... are cross-validation, in which all available data are iteratively split into training and testing data, and the use of blind sets generated separately from the data used to construct the predictive method. In the present study, we have compared cross-validated prediction performances generated on our last...

  2. Increasing the Performance and Reliability of Power Boiler by Monitoring Thermal and Strength Parameters

    Directory of Open Access Journals (Sweden)

    Sobota Tomasz

    2017-01-01

    Full Text Available The paper presents a method for determination of thermo-flow parameters for steam boilers. This method allows to perform the calculations of the boiler furnace chamber and heat flow rates absorbed by superheater stages. These parameters are important for monitoring the performance of the power unit. Knowledge of these parameters allows determining the degree of the furnace chamber slagging. The calculation can be performed in online mode and use to monitoring of steam boiler. The presented method allows to the operation of steam boiler with high efficiency.

  3. Development of corrosion models to ensure reliable performance of nuclear power plants

    International Nuclear Information System (INIS)

    Kritzky, V.G.; Stjazhkin, P.S.

    1993-01-01

    The safety and reliability of the coolant circuits in nuclear power plants depend much on corrosion and corrosion products transfer processes. Various empirical models have been developed which are applicable to particular sets of operational conditions. In our laboratory a corrosion model has been worked out, which is based on the thermodynamic properties of the compounds, participating in corrosion process and on the assumption, that the corrosion process is controlled by the solubilities of the corrosion products forming the surface oxide layer. The validity of the model has been verified by use of retrospective experimental data, which have been obtained for a series of structural materials such as e.g., carbon and stainless steels, Cu-, Al-, and Zr alloys. With regard for hydriding the model satisfactorily describes stress corrosion cracking process in water-salt environments. This report describes a model based on the thermodynamic properties of the compounds participating in the corrosion process, and on the assumption that the corrosion process is controlled by the solubilities of the corrosion products forming the surface oxide layer

  4. The Maintenance Personnel Performance Simulation (MAPPS) model: A human reliability analysis tool

    International Nuclear Information System (INIS)

    Knee, H.E.

    1985-01-01

    The Maintenance Personnel Performance Simulation (MAPPS) model is a computerized, stochastic, task-oriented human behavioral model developed to provide estimates of nuclear power plant (NPP) maintenance team performance measures. It is capable of addressing person-machine, person-environment, and person-person relationships, and accounts for interdependencies that exist between the subelements that make up the maintenance task of interest. The primary measures of performance estimated by MAPPS are: 1) the probability of successfully completing the task of interest and 2) the task duration time. MAPPS also estimates a host of other performance indices, including the probability of an undetected error, identification of the most- and least-likely error-prone subelements, and maintenance team stress profiles during task execution

  5. Reliability of six physical performance tests in older people with dementia

    NARCIS (Netherlands)

    Blankevoort, C.G.; Heuvelen, M.J.; Scherder, E.J.A.

    2012-01-01

    Background. Physical performance tests are important for assessing the effect of physical activity interventions in older people with dementia, but their psychometric properties have not been systematically established within this specific population. Objective. The purpose of this study was to

  6. Reliability of Six Physical Performance Tests in Older People With Dementia

    NARCIS (Netherlands)

    Blankevoort, Christiaan G.; van Heuvelen, Marieke J. G.; Scherder, Erik J. A.

    Background. Physical performance tests are important for assessing the effect of physical activity interventions in older people with dementia, but their psychometric properties have not been systematically established within this specific population. Objective. The purpose of this study was to

  7. Performance-based maintenance of gas turbines for reliable control of degraded power systems

    Science.gov (United States)

    Mo, Huadong; Sansavini, Giovanni; Xie, Min

    2018-03-01

    Maintenance actions are necessary for ensuring proper operations of control systems under component degradation. However, current condition-based maintenance (CBM) models based on component health indices are not suitable for degraded control systems. Indeed, failures of control systems are only determined by the controller outputs, and the feedback mechanism compensates the control performance loss caused by the component deterioration. Thus, control systems may still operate normally even if the component health indices exceed failure thresholds. This work investigates the CBM model of control systems and employs the reduced control performance as a direct degradation measure for deciding maintenance activities. The reduced control performance depends on the underlying component degradation modelled as a Wiener process and the feedback mechanism. To this aim, the controller features are quantified by developing a dynamic and stochastic control block diagram-based simulation model, consisting of the degraded components and the control mechanism. At each inspection, the system receives a maintenance action if the control performance deterioration exceeds its preventive-maintenance or failure thresholds. Inspired by realistic cases, the component degradation model considers random start time and unit-to-unit variability. The cost analysis of maintenance model is conducted via Monte Carlo simulation. Optimal maintenance strategies are investigated to minimize the expected maintenance costs, which is a direct consequence of the control performance. The proposed framework is able to design preventive maintenance actions on a gas power plant, to ensuring required load frequency control performance against a sudden load increase. The optimization results identify the trade-off between system downtime and maintenance costs as a function of preventive maintenance thresholds and inspection frequency. Finally, the control performance-based maintenance model can reduce

  8. Maintenance Personnel Performance Simulation (MAPPS) model: a human reliability analysis tool

    International Nuclear Information System (INIS)

    Knee, H.E.

    1985-01-01

    The Maintenance Personnel Performance Simulation (MAPPS) model is a computerized, stochastic, task-oriented human behavioral model developed to provide estimates of nuclear power plant (NPP) maintenance team performance measures. It is capable of addressing person-machine, person-environment, and person-person relationships, and accounts for interdependencies that exist between the subelements that make up the maintenance task of interest. The primary measures of performance estimated by MAPPS are: (1) the probability of successfully completing the task of interest; and (2) the task duration time. MAPPS also estimates a host of other performance indices, including the probability of an undetected error, identification of the most- and least-likely error-prone subelements, and maintenance team stress profiles during task execution. The MAPPS model was subjected to a number of evaluation efforts that focused upon its practicality, acceptability, usefulness, and validity. Methods used for these efforts included a case method approach, consensus estimation, and comparison with observed task performance measures at a NPP. Favorable results, such as close agreement between task duration times for two tasks observed in the field (67.0 and 119.8 minutes, respectively), and estimates by MAPPS (72.0 and 124.0 minutes, respectively) enhance the confidence in the future use of MAPPS. 8 refs., 1 fig

  9. Risk and reliability allocation to risk control

    International Nuclear Information System (INIS)

    Vojnovic, D.; Kozuh, M.

    1992-01-01

    The risk allocation procedure is used as an analytical model to support the optimal decision making for reliability/availability improvement planning. Both levels of decision criteria, the plant risk measures and plant performance indices, are used in risk allocation procedure. Decision support system uses the multi objective decision making concept. (author) [sl

  10. The reliability of test results from simple test samples in predicting the fatigue performance of automotive components

    International Nuclear Information System (INIS)

    Fourlaris, G.; Ellwood, R.; Jones, T.B.

    2007-01-01

    The use of high strength steels (HSS) in automotive components is steadily increasing as automotive designers use modern steel grades to improve structural performance, reduce vehicle weight and enhance crash performance. Weight reduction can be achieved by substituting mild steel with a thinner gauge HSS, however, it must be ensured that no deterioration in performance including fatigue capability occurs. In this study, tests have been carried out to determine the effects that gauge and material strength have on the fatigue performance of a fusion welded automotive suspension arm. Current finite element (FE) modelling and fatigue prediction techniques have been evaluated to determine their reliability when used for thin strip steels. Results have shown the fatigue performance of welded components to be independent of the strength of the parent material for the steel grades studied, with material thickness and joining process the key features determining the fatigue performance. The correlation between the fatigue performance of simple welded samples under uniaxial, constant amplitude loading and complex components under biaxial in service road load data, has been shown to be unreliable. This study also indicates that with the application of modern technologies, such as tailor-welded blanks (TWB), significant weight savings can be achieved. This is demonstrated by a 19% weight reduction with no detrimental effect on the fatigue performance

  11. Agreement and Reliability of Functional Performance and Muscle Power in Patients with Advanced Osteoarthritis of the Hip or Knee

    DEFF Research Database (Denmark)

    Villadsen, Allan; Roos, Ewa M; Overgaard, Søren

    2012-01-01

    -time repeated chair stands, and repeated unilateral knee bending). RESULTS: For single-joint and multijoint maximal peak power and functional performance measures, we demonstrated poor (CVws, approximately 25%, single-joint hip extension) and moderate (CVws, approximately 15%, multijoint leg extension press......OBJECTIVE: The purpose of this study was to test the reproducibility and clinical feasibility of three functional performance measures and five single-joint or multijoint muscle power measures. DESIGN: Twenty patients with a mean age of 68.7 ± 7.2 yrs with severe hip or knee osteoarthritis were...... assessed for test-retest reliability and agreement on two occasions 1 wk apart. The outcomes were maximal single-joint muscle power (hip extension/abduction and knee extension/flexion), maximal muscle power during multijoint leg extension press, and functional performance measures (20-m walk, five...

  12. Operational safety performance indicator system - a management tool for the self assessment of safety and reliability of nuclear power plants

    International Nuclear Information System (INIS)

    Anil Kumar; Mandowara, S.L.; Mittal, S.

    2006-01-01

    Operational Safety Performance Indicator system is one of the self assessment tools for station management to monitor safety and reliability of nuclear power plants. It provides information to station management about the performance of various areas of the plants by means of different colours of relevant performance indicators. Such systems have been implemented at many nuclear power plants in the world and have been considered as strength during WANO Peer Review. IAEA had a Coordinated Research Programme (CRP) on this with several countries participating including India. In NPCIL this system has been implemented in KAPS about a year back and found very useful in identifying areas which needs to be given more attention. Based on the KAPS feedback Implementation of this system has been taken up in RAPS-3 and 4 and KGS-l and 2. (author)

  13. Medicalising normality? Using a simulated dataset to assess the performance of different diagnostic criteria of HIV-associated cognitive impairment

    Science.gov (United States)

    De Francesco, Davide; Leech, Robert; Sabin, Caroline A.; Winston, Alan

    2018-01-01

    Objective The reported prevalence of cognitive impairment remains similar to that reported in the pre-antiretroviral therapy era. This may be partially artefactual due to the methods used to diagnose impairment. In this study, we evaluated the diagnostic performance of the HIV-associated neurocognitive disorder (Frascati criteria) and global deficit score (GDS) methods in comparison to a new, multivariate method of diagnosis. Methods Using a simulated ‘normative’ dataset informed by real-world cognitive data from the observational Pharmacokinetic and Clinical Observations in PeoPle Over fiftY (POPPY) cohort study, we evaluated the apparent prevalence of cognitive impairment using the Frascati and GDS definitions, as well as a novel multivariate method based on the Mahalanobis distance. We then quantified the diagnostic properties (including positive and negative predictive values and accuracy) of each method, using bootstrapping with 10,000 replicates, with a separate ‘test’ dataset to which a pre-defined proportion of ‘impaired’ individuals had been added. Results The simulated normative dataset demonstrated that up to ~26% of a normative control population would be diagnosed with cognitive impairment with the Frascati criteria and ~20% with the GDS. In contrast, the multivariate Mahalanobis distance method identified impairment in ~5%. Using the test dataset, diagnostic accuracy [95% confidence intervals] and positive predictive value (PPV) was best for the multivariate method vs. Frascati and GDS (accuracy: 92.8% [90.3–95.2%] vs. 76.1% [72.1–80.0%] and 80.6% [76.6–84.5%] respectively; PPV: 61.2% [48.3–72.2%] vs. 29.4% [22.2–36.8%] and 33.9% [25.6–42.3%] respectively). Increasing the a priori false positive rate for the multivariate Mahalanobis distance method from 5% to 15% resulted in an increase in sensitivity from 77.4% (64.5–89.4%) to 92.2% (83.3–100%) at a cost of specificity from 94.5% (92.8–95.2%) to 85.0% (81.2–88

  14. Reliability in the performance-based concept of fib Model Code 2010

    NARCIS (Netherlands)

    Bigaj-van Vliet, A.; Vrouwenvelder, T.

    2013-01-01

    The design philosophy of the new fib Model Code for Concrete Structures 2010 represents the state of the art with regard to performance-based approach to the design and assessment of concrete structures. Given the random nature of quantities determining structural behaviour, the assessment of

  15. Determination of validity and reliability of performance assessments tasks developed for selected topics in high school chemistry

    Science.gov (United States)

    Zichittella, Gail Eberhardt

    The primary purpose of this study was to validate performance assessments, which can be used as teaching and assessment instruments in high school science classrooms. This study evaluated the classroom usability of these performance instruments and establishes the interrater reliability of the scoring rubrics when used by classroom teachers. The assessment instruments were designed to represent two levels of scientific inquiry. The high level of inquiry tasks are relatively unstructured in terms of student directions; the low inquiry tasks provided more structure for the student. The tasks cover two content topics studied in chemistry (scientific observation and density). Students from a variety of Western New York school districts who were enrolled in chemistry classes and other science courses were involved in completion of the tasks at the two levels of inquiry. The chemistry students completed the NYS Regents Examination in Chemistry. Their classroom teachers were interviewed and completed a questionnaire to aid in the establishment their epistemological view on the inclusion of inquiry based learning in the science classroom. Data showed that the performance assessment tasks were reliable, valid and helpful for obtaining a more complete picture of the students' scientific understanding. The teacher participants reported no difficulty with the usability of the task in the high school chemistry setting. Collected data gave no evidence of gender bias with reference to the performance tasks or the NYS Regents Chemistry Examination. Additionally, it was shown that the instructors' classroom practices do have an effect upon the students' achievement on the performance tasks and the NYS Regents examination. Data also showed that achievement on the performance tasks was influenced by the number of years of science instruction students had received.

  16. Reliable quantification of BOLD fMRI cerebrovascular reactivity despite poor breath-hold performance.

    Science.gov (United States)

    Bright, Molly G; Murphy, Kevin

    2013-12-01

    Cerebrovascular reactivity (CVR) can be mapped using BOLD fMRI to provide a clinical insight into vascular health that can be used to diagnose cerebrovascular disease. Breath-holds are a readily accessible method for producing the required arterial CO2 increases but their implementation into clinical studies is limited by concerns that patients will demonstrate highly variable performance of breath-hold challenges. This study assesses the repeatability of CVR measurements despite poor task performance, to determine if and how robust results could be achieved with breath-holds in patients. Twelve healthy volunteers were scanned at 3 T. Six functional scans were acquired, each consisting of 6 breath-hold challenges (10, 15, or 20 s duration) interleaved with periods of paced breathing. These scans simulated the varying breath-hold consistency and ability levels that may occur in patient data. Uniform ramps, time-scaled ramps, and end-tidal CO2 data were used as regressors in a general linear model in order to measure CVR at the grey matter, regional, and voxelwise level. The intraclass correlation coefficient (ICC) quantified the repeatability of the CVR measurement for each breath-hold regressor type and scale of interest across the variable task performances. The ramp regressors did not fully account for variability in breath-hold performance and did not achieve acceptable repeatability (ICC0.4). Further analysis of intra-subject CVR variability across the brain (ICCspatial and voxelwise correlation) supported the use of end-tidal CO2 data to extract robust whole-brain CVR maps, despite variability in breath-hold performance. We conclude that the incorporation of end-tidal CO2 monitoring into scanning enables robust, repeatable measurement of CVR that makes breath-hold challenges suitable for routine clinical practice. © 2013.

  17. Development of a working set of waste package performance criteria for deepsea disposal of low-level radioactive waste. Final report

    International Nuclear Information System (INIS)

    Columbo, P.; Fuhrmann, M.; Neilson, R.M. Jr; Sailor, V.L.

    1982-11-01

    The United States ocean dumping regulations developed pursuant to PL92-532, the Marine Protection, Research, and Sanctuaries Act of 1972, as amended, provide for a general policy of isolation and containment of low-level radioactive waste after disposal into the ocean. In order to determine whether any particular waste packaging system is adequate to meet this general requirement, it is necessary to establish a set of performance criteria against which to evaluate a particular packaging system. These performance criteria must present requirements for the behavior of the waste in combination with its immobilization agent and outer container in a deepsea environment. This report presents a working set of waste package performance criteria, and includes a glossary of terms, characteristics of low-level radioactive waste, radioisotopes of importance in low-level radioactive waste, and a summary of domestic and international regulations which control the ocean disposal of these wastes

  18. Reliability assessment of Indian Point Unit 3 containment structure

    International Nuclear Information System (INIS)

    Kawakami, J.; Hwang, H.; Chang, M.T.; Reich, M.

    1984-01-01

    In the current design criteria, the load combinations specified for design of concrete containment structures are in the deterministic formats. However, by applying the probability-based reliability method developed by BNL to the concrete containment structures designed according to the criteria, it is possible to evaluate the reliability levels implied in the current design criteria. For this purpose, the reliability analysis is applied to the Indian Point Unit No. 3 containment. The details of the containment structure such as the geometries and the rebar arrangements, etc., are taken from the working drawings and the final safety analysis reports. Three kinds of loads are considered in the reliability analysis. They are, dead load (D), accidental pressure due to a large LOCA (P), and earthquake ground acceleration (E). Reliability analysis of the containment subjected to all combinations of loads is performed. Results are presented in this report

  19. Operating performance and reliability of CANDU PHWR fuel channels in Canada

    International Nuclear Information System (INIS)

    Strachan, B.; Brown, D.R.

    1983-03-01

    CANDU nuclear plants use many small-diameter high-pressure fuel channels. Good operating performance from the CANDU fuel channels has made a major contribution to the world-leading operating record of the CANDU nuclear power plants. As of 1982 December 31, there were 7,480 fuel channels installed in 18 CANDU reactors over 500 MW(e) in size. Eight of these reactors have been declared in-service and have accumulated 24,000 fuel channel-years of operation. The only significant operating problems with fuel channels have been the occurrence of leaking cracks in 70 fuel channels and a larger amount of axial creep on the early reactors than was originally provided for in the design. Both of these problems have been corrected on all CANDU reactors built since the Bruce GS 'A' station and the newer reactors should exhibit even better performance

  20. Embedded Sensors and Controls to Improve Component Performance and Reliability -- Loop-scale Testbed Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Melin, Alexander M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kisner, Roger A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-09-01

    Embedded instrumentation and control systems that can operate in extreme environments are challenging to design and operate. Extreme environments limit the options for sensors and actuators and degrade their performance. Because sensors and actuators are necessary for feedback control, these limitations mean that designing embedded instrumentation and control systems for the challenging environments of nuclear reactors requires advanced technical solutions that are not available commercially. This report details the development of testbed that will be used for cross-cutting embedded instrumentation and control research for nuclear power applications. This research is funded by the Department of Energy's Nuclear Energy Enabling Technology program's Advanced Sensors and Instrumentation topic. The design goal of the loop-scale testbed is to build a low temperature pump that utilizes magnetic bearing that will be incorporated into a water loop to test control system performance and self-sensing techniques. Specifically, this testbed will be used to analyze control system performance in response to nonlinear and cross-coupling fluid effects between the shaft axes of motion, rotordynamics and gyroscopic effects, and impeller disturbances. This testbed will also be used to characterize the performance losses when using self-sensing position measurement techniques. Active magnetic bearings are a technology that can reduce failures and maintenance costs in nuclear power plants. They are particularly relevant to liquid salt reactors that operate at high temperatures (700 C). Pumps used in the extreme environment of liquid salt reactors provide many engineering challenges that can be overcome with magnetic bearings and their associated embedded instrumentation and control. This report will give details of the mechanical design and electromagnetic design of the loop-scale embedded instrumentation and control testbed.

  1. Linking Quality Assurance to Performance Improvement to Produce a High Reliability Organization

    International Nuclear Information System (INIS)

    Silvey, Andrea B.; Warrick, Louise H.

    2008-01-01

    Three basic change management models are currently used in healthcare to produce and sustain quality improvement. We have presented the context to determine where any particular organization stands within these paradigms. We also have introduced a change-management tool used to assess, plan, and monitor leadership effort and commitment to quality improvement and culture change activities, tracked as 'momentum for change.' This 'momentum' is measured at eight discrete levels, from recognizing a performance gap to officially implementing changes intended to improve quality

  2. How reliable are geometry-based building indices as thermal performance indicators?

    International Nuclear Information System (INIS)

    Rodrigues, Eugénio; Amaral, Ana Rita; Gaspar, Adélio Rodrigues; Gomes, Álvaro

    2015-01-01

    Highlights: • Geometry-based building indices are tested in different European climate regions. • Building design programs are used to randomly generate sets of simulation models. • Some indices correlate in specific climates and design programs. • Shape-based Relative Compactness presented the best correlation of all indices. • Window-to-Surface Ratio was the window-based index with best correlation. - Abstract: Architects and urban planners have been relying on geometry-based indices to design more energy efficient buildings for years. The advantage of such indices is their ease of use and capability to capture the relation of a few geometric variables with the building’s performance. However, such relation is usually found using only a few simple building models and considering only a few climate regions. This paper presents the analysis of six geometry-based building indices to determine their adequacy in eight different climate regions in Europe. For each location, three residential building design programs were used as building specifications. Two algorithms were employed to randomly generate and assess the thermal performance of three sets of 500 alternative building models. The results show that geometry-based indices only correlate with the buildings’ thermal performance according to specific climate regions and building design programs

  3. Spatial learning and psychomotor performance of C57BL/6 mice: age sensitivity and reliability of individual differences.

    Science.gov (United States)

    de Fiebre, Nancyellen C; Sumien, Nathalie; Forster, Michael J; de Fiebre, Christopher M

    2006-09-01

    Two tests often used in aging research, the elevated path test and the Morris water maze test, were examined for their application to the study of brain aging in a large sample of C57BL/6JNia mice. Specifically, these studies assessed: (1) sensitivity to age and the degree of interrelatedness among different behavioral measures derived from these tests, (2) the effect of age on variation in the measurements, and (3) the reliability of individual differences in performance on the tests. Both tests detected age-related deficits in group performance that occurred independently of each other. However, analysis of data obtained on the Morris water maze test revealed three relatively independent components of cognitive performance. Performance in initial acquisition of spatial learning in the Morris maze was not highly correlated with performance during reversal learning (when mice were required to learn a new spatial location), whereas performance in both of those phases was independent of spatial performance assessed during a single probe trial administered at the end of acquisition training. Moreover, impaired performance during initial acquisition could be detected at an earlier age than impairments in reversal learning. There were modest but significant age-related increases in the variance of both elevated path test scores and in several measures of learning in the Morris maze test. Analysis of test scores of mice across repeated testing sessions confirmed reliability of the measurements obtained for cognitive and psychomotor function. Power calculations confirmed that there are sufficiently large age-related differences in elevated path test performance, relative to within age variability, to render this test useful for studies into the ability of an intervention to prevent or reverse age-related deficits in psychomotor performance. Power calculations indicated a need for larger sample sizes for detection of intervention effects on cognitive components of the

  4. Development of an Expanded, High Reliability Cost and Performance Database for In Situ Remediation Technologies

    Science.gov (United States)

    2016-03-01

    Biomass (cells/mL) 1.0 E+4 1.8 E+7 5.3 E+6 -- 2.7 E+7 DNA (ug/L) 0.04 72 21 -- 108 Dehalococcoides (cells/L) -- -- -- -- ə.0 E+4 Field Measurements...indicates that bioremediation processes could remain on- going for some time at this site. Total biomass concentrations in the most recent sample...of medium to coarse-grained sand and crushed shells . The Pilot Test was performed with three injection wells and three extraction wells over a 20

  5. Reliability calculations

    International Nuclear Information System (INIS)

    Petersen, K.E.

    1986-03-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very complex systems. In order to increase the applicability of the programs variance reduction techniques can be applied to speed up the calculation process. Variance reduction techniques have been studied and procedures for implementation of importance sampling are suggested. (author)

  6. A dissociation between engagement and learning: Enthusiastic instructions fail to reliably improve performance on a memory task.

    Directory of Open Access Journals (Sweden)

    Benjamin A Motz

    Full Text Available Despite widespread assertions that enthusiasm is an important quality of effective teaching, empirical research on the effect of enthusiasm on learning and memory is mixed and largely inconclusive. To help resolve these inconsistencies, we conducted a carefully-controlled laboratory experiment, investigating whether enthusiastic instructions for a memory task would improve recall accuracy. Scripted videos, either enthusiastic or neutral, were used to manipulate the delivery of task instructions. We also manipulated the sequence of learning items, replicating the spacing effect, a known cognitive technique for memory improvement. Although spaced study reliably improved test performance, we found no reliable effect of enthusiasm on memory performance across two experiments. We did, however, find that enthusiastic instructions caused participants to respond to more item prompts, leaving fewer test questions blank, an outcome typically associated with increased task motivation. We find no support for the popular claim that enthusiastic instruction will improve learning, although it may still improve engagement. This dissociation between motivation and learning is discussed, as well as its implications for education and future research on student learning.

  7. A dissociation between engagement and learning: Enthusiastic instructions fail to reliably improve performance on a memory task.

    Science.gov (United States)

    Motz, Benjamin A; de Leeuw, Joshua R; Carvalho, Paulo F; Liang, Kaley L; Goldstone, Robert L

    2017-01-01

    Despite widespread assertions that enthusiasm is an important quality of effective teaching, empirical research on the effect of enthusiasm on learning and memory is mixed and largely inconclusive. To help resolve these inconsistencies, we conducted a carefully-controlled laboratory experiment, investigating whether enthusiastic instructions for a memory task would improve recall accuracy. Scripted videos, either enthusiastic or neutral, were used to manipulate the delivery of task instructions. We also manipulated the sequence of learning items, replicating the spacing effect, a known cognitive technique for memory improvement. Although spaced study reliably improved test performance, we found no reliable effect of enthusiasm on memory performance across two experiments. We did, however, find that enthusiastic instructions caused participants to respond to more item prompts, leaving fewer test questions blank, an outcome typically associated with increased task motivation. We find no support for the popular claim that enthusiastic instruction will improve learning, although it may still improve engagement. This dissociation between motivation and learning is discussed, as well as its implications for education and future research on student learning.

  8. Intra-system reliability of SICS: video-tracking system (Digital.Stadium®) for performance analysis in football.

    Science.gov (United States)

    Beato, Marco; Jamil, Mikael

    2017-05-09

    The correct evaluation of external load parameters is a key factor in professional football. The instrumentations usually utilised to quantify the external load parameters during official matches are Video-Tracking Systems (VTS). VTS is a technology that records two- dimensional position data (x and y) at high sampling rates (over 25 Hz). The aim of this study was to evaluate the intra-system reliability of Digital.Stadium® VTS. 28 professional male football players taking part in the Italian Serie A (age 24 ± 6 years, body mass 79.5 ± 7.8 kg, stature 1.83 ± 0.05 m) during the 2015/16 season were enrolled in this study (Team A and Team B). Video-analysis was done during an official match and data analysis was performed immediately after the game ended and then replicated a week later. This study reported a near perfect relationship between the initial analysis (analysis 1) and the replicated analysis undertaken a week later (analysis 2). R2 coefficients were highly significant for each of the performance parameters, p power of 9.65 ± 1.64 w kg-1 and 9.58 ± 1.61 w kg-1, in analysis 1 and analysis 2, respectively. The findings reported in this study underlined that all data reported by Digital.Stadium® VTS showed high levels of absolute and relative reliability.

  9. Evaluation and performance of arccheck and film using gamma criteria in pre-treatment quality assurance of stereotactic ablative radiotherapy

    Directory of Open Access Journals (Sweden)

    Prabhakar Ramachandran

    2017-01-01

    Full Text Available Aim: The aim of this study is to assess the use of ArcCHECK (AC as an alternative method to replace film dosimetry for pre-treatment quality assurance (QA of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy (IMRT, and volumetric-modulated arc therapy (VMAT stereotactic ablative radiotherapy (SABR treatment plans. Materials and Methods: Twenty-five patients with a varied diagnosis of lung, spine, sacrum, sternum, ribs, scapula, and femur undergoing SABR were selected for this study. Pre-treatment QA was performed for all the patients using ionization chamber and film dosimetry. Measurements were also carried out on an AC phantom. The planned and measured doses from the AC device and EBT3 films were compared using four different gamma criteria: 2%/2 mm, 3%/2 mm, 3%/1 mm, and 3%/3 mm. Results: The mean gamma passing rates at 3%/3 mm for all non-spine SABR cases were 98.79 ± 0.96 and 99.27 ± 1.03 with AC and films, respectively. The mean passing rates at 3%/2 mm for AC and films were 98.76 ± 0.42 and 99.43 ± 0.27 respectively for spine VMAT SABR, and 87.15 ± 2.45 and 99.79 ± 0.14 respectively for spine IMRT SABR. In the case of spine tumors, the gamma criterion was tightened due to the proximity of spinal cord to the planning target volume. Our results show that AC provides good results for all VMAT SABR plans. Conclusion: The AC results at 3%/3 mm were in good agreement with film dosimetry for most cases. We observed a significant reduction in QA time on using AC for SABR QA. This study showed that AC results are comparable to film dosimetry for all studied sites except for spine IMRT SABR.

  10. Test-retest reliability of maximal leg muscle power and functional performance measures in patients with severe osteoarthritis (OA)

    DEFF Research Database (Denmark)

    Villadsen, Allan; Roos, Ewa M.; Overgaard, Søren

    Abstract : Purpose To evaluate the reliability of single-joint and multi-joint maximal leg muscle power and functional performance measures in patients with severe OA. Background Muscle power, taking both strength and velocity into account, is a more functional measure of lower extremity muscle...... and scheduled for unilateral total hip (n=9) or knee (n=11) replacement. Patients underwent a test battery on two occasions separated by approximately one week (range 7 to 11 days). Muscle power was measured using: 1. A linear encoder, unilateral lower limb isolated single-joint dynamic movement, e.g. knee...... flexion 2. A leg extension press, unilateral multi-joint knee and hip extension Functional performance was measured using: 1. 20 m walk usual pace 2. 20 m walk maximal pace 3. 5 times chair stands 4. Maximal number of knee bends/30sec Pain was measured on a VAS prior to and after conducting the entire...

  11. Performance of the 2012 Systemic Lupus International Collaborating Clinics classification criteria versus the 1997 American College of Rheumatology classification criteria in adult and juvenile systemic lupus erythematosus. A systematic review and meta-analysis.

    Science.gov (United States)

    Hartman, Esther A R; van Royen-Kerkhof, Annet; Jacobs, Johannes W G; Welsing, Paco M J; Fritsch-Stork, Ruth D E

    2018-03-01

    To evaluate the performance in classifying systemic lupus erythematosus by the 2012 Systemic Lupus International Collaborating Clinics criteria (SLICC'12), versus the revised American College of Rheumatology criteria from 1997 (ACR'97) in adult and juvenile SLE patients. A systematic literature search was conducted in PubMed and Embase for studies comparing SLICC'12 and ACR'97 with clinical diagnosis. A meta-analysis was performed to estimate the sensitivity and specificity of SLICC'12 and ACR'97. To assess classification earlier in the disease by either set, sensitivity and specificity were compared for patients with disease duration <5years. Sensitivity and specificity of individual criteria items were also assessed. In adult SLE (nine studies: 5236 patients, 1313 controls), SLICC'12 has higher sensitivity (94.6% vs. 89.6%) and similar specificity (95.5% vs. 98.1%) compared to ACR'97. For juvenile SLE (four studies: 568 patients, 339 controls), SLICC'12 demonstrates higher sensitivity (99.9% vs. 84.3%) than ACR'97, but much lower specificity (82.0% vs. 94.1%). SLICC'12 classifies juvenile SLE patients earlier in disease course. Individual items contributing to diagnostic accuracy are low complement, anti-ds DNA and acute cutaneous lupus in SLICC'12, and the immunologic and hematologic disorder in ACR'97. Based on sensitivity and specificity SLICC'12 is best for adult SLE. Following the view that higher specificity, i.e. avoidance of false positives, is preferable, ACR'97 is best for juvenile SLE even if associated with lower sensitivity. Our results on the contribution of the individual items of SLICC'12 and ACR´97 may be of value in future efforts to update classification criteria. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  12. A Microfabricated Segmented-Involute-Foil Regenerator for Enhancing Reliability and Performance of Stirling Engines

    Science.gov (United States)

    Ibrahim, Mounir; Danila, Daniel; Simon, Terrence; Mantell, Susan; Sun, Liyong; Gadeon, David; Qiu, Songgang; Wood, Gary; Kelly, Kevin; McLean, Jeffrey

    2007-01-01

    An actual-size microfabricated regenerator comprised of a stack of 42 disks, 19 mm diameter and 0.25 mm thick, with layers of microscopic, segmented, involute-shaped flow channels was fabricated and tested. The geometry resembles layers of uniformly-spaced segmented-parallel-plates, except the plates are curved. Each disk was made from electro-plated nickel using the LiGA process. This regenerator had feature sizes close to those required for an actual Stirling engine but the overall regenerator dimensions were sized for the NASA/Sunpower oscillating-flow regenerator test rig. Testing in the oscillating-flow test rig showed the regenerator performed extremely well, significantly better than currently used random-fiber material, producing the highest figures of merit ever recorded for any regenerator tested in that rig over its approximately 20 years of use.

  13. Reliability residual-life prediction method for thermal aging based on performance degradation

    International Nuclear Information System (INIS)

    Ren Shuhong; Xue Fei; Yu Weiwei; Ti Wenxin; Liu Xiaotian

    2013-01-01

    The paper makes the study of the nuclear power plant main pipeline. The residual-life of the main pipeline that failed due to thermal aging has been studied by the use of performance degradation theory and Bayesian updating methods. Firstly, the thermal aging impact property degradation process of the main pipeline austenitic stainless steel has been analyzed by the accelerated thermal aging test data. Then, the thermal aging residual-life prediction model based on the impact property degradation data is built by Bayesian updating methods. Finally, these models are applied in practical situations. It is shown that the proposed methods are feasible and the prediction accuracy meets the needs of the project. Also, it provides a foundation for the scientific management of aging management of the main pipeline. (authors)

  14. Chapter 1: Reliably Measuring the Performance of Emerging Photovoltaic Solar Cells

    Energy Technology Data Exchange (ETDEWEB)

    Rumbles, Garry [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Reese, Matthew O [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Marshall, Ashley [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-08

    Determining the power conversion efficiency of photovoltaic solar cells, especially those from new, emerging areas of technology, is important if advances in performance are to be made. However, although precise measurements are important, it is the accuracy of these types of measurements that can cause issues. Accurate measurements not only promote the development of new technology platforms, but they also enable comparisons with established technologies and allow assessments of advancements within the same field. This chapter provides insights into how measurements can be made with reasonable accuracy using both the components of the measuring system and a good protocol to acquire good data. The chapter discusses how to measure a calibrated lamp spectrum, determine a spectral mismatch factor, identify the correct reference cell and filter, define the illuminated active area, measure J-V curves to avoid any hysteresis effects, take note of sample degradation issues and avoid the temptation to artificially enhance efficiency data.

  15. Performance of synchrotron x-ray monochromators under heat load: How reliable are the predictions?

    International Nuclear Information System (INIS)

    Freund, A.K.; Hoszowska, J.; Migliore, J.-S.; Mocella, V.; Zhang, L.; Ferrero, C.

    2000-01-01

    With the ongoing development of insertion devices with smaller gaps the heat load generated by modern synchrotron sources increases continuously. To predict the overall performance of experiments on beam lines it is of crucial importance to be able to predict the efficiency of x-ray optics and in particular that of crystal monochromators. We report on a detailed comparison between theory and experiment for a water-cooled silicon crystal exposed to bending magnet radiation of up to 237 W total power and 1.3 W/mm2 power density. The thermal deformation has been calculated by the code ANSYS and its output has been injected into a finite difference code based on the Takagi-Taupin diffraction theory for distorted crystals. Several slit settings, filters and reflection orders were used to vary the geometrical conditions and the x-ray penetration depth in the crystal. In general, good agreement has been observed between the calculated and the observed values for the rocking curve width

  16. How do nurses and teachers perform breast self-examination: are they reliable sources of information?

    Directory of Open Access Journals (Sweden)

    Ozvurmaz Safiye

    2007-06-01

    Full Text Available Abstract Background Breast cancer is the most common cause of cancer-related deaths among women worldwide. The aim of the present study was to determine and compare knowledge, behavior and attitudes among female nurses and teachers concerning breast self-examination (BSE. Methods Two-hundred and eighty nine women working in Aydin, Turkey (125 nurses and 164 teachers were included in the study. The data were collected using a questionnaire designed to measure the knowledge, attitudes and behavior of the groups. Analysis involved percentiles, χ2 tests, t tests and factor analysis. Results The knowledge of nurses about BSE was higher than that of teachers (81.5% versus 45.1%; p 0.05, whereas skills in performing self-examination were higher in nurses (p Conclusion We conclude that nurses and teachers should be supported with information enabling them to accomplish their roles in the community. To improve BSE practice, it is crucial to coordinate continuous and planned education.

  17. Charging performance of automotive batteries-An underestimated factor influencing lifetime and reliable battery operation

    Science.gov (United States)

    Sauer, Dirk Uwe; Karden, Eckhard; Fricke, Birger; Blanke, Holger; Thele, Marc; Bohlen, Oliver; Schiffer, Julia; Gerschler, Jochen Bernhard; Kaiser, Rudi

    Dynamic charge acceptance and charge acceptance under constant voltage charging conditions are for two reasons essential for lead-acid battery operation: energy efficiency in applications with limited charging time (e.g. PV systems or regenerative braking in vehicles) and avoidance of accelerated ageing due to sulphation. Laboratory tests often use charge regimes which are beneficial for the battery life, but which differ significantly from the operating conditions in the field. Lead-acid batteries in applications with limited charging time and partial-state-of-charge operation are rarely fully charged due to their limited charge acceptance. Therefore, they suffer from sulphation and early capacity loss. However, when appropriate charging strategies are applied most of the lost capacity and thus performance for the user may be recovered. The paper presents several aspects of charging regimes and charge acceptance. Theoretical and experimental investigations show that temperature is the most critical parameter. Full charging within short times can be achieved only at elevated temperatures. A strong dependency of the charge acceptance during charging pulses on the pre-treatment of the battery can be observed, which is not yet fully understood. But these effects have a significant impact on the fuel efficiency of micro-hybrid electric vehicles.

  18. Embedded Sensors and Controls to Improve Component Performance and Reliability -- Bench-scale Testbed Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Melin, Alexander M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kisner, Roger A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Drira, Anis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Reed, Frederick K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-09-01

    Embedded instrumentation and control systems that can operate in extreme environments are challenging due to restrictions on sensors and materials. As a part of the Department of Energy's Nuclear Energy Enabling Technology cross-cutting technology development programs Advanced Sensors and Instrumentation topic, this report details the design of a bench-scale embedded instrumentation and control testbed. The design goal of the bench-scale testbed is to build a re-configurable system that can rapidly deploy and test advanced control algorithms in a hardware in the loop setup. The bench-scale testbed will be designed as a fluid pump analog that uses active magnetic bearings to support the shaft. The testbed represents an application that would improve the efficiency and performance of high temperature (700 C) pumps for liquid salt reactors that operate in an extreme environment and provide many engineering challenges that can be overcome with embedded instrumentation and control. This report will give details of the mechanical design, electromagnetic design, geometry optimization, power electronics design, and initial control system design.

  19. DJFS: Providing Highly Reliable and High‐Performance File System with Small‐Sized

    Directory of Open Access Journals (Sweden)

    Junghoon Kim

    2017-11-01

    Full Text Available File systems and applications try to implement their own update protocols to guarantee data consistency, which is one of the most crucial aspects of computing systems. However, we found that the storage devices are substantially under‐utilized when preserving data consistency because they generate massive storage write traffic with many disk cache flush operations and force‐unit‐access (FUA commands. In this paper, we present DJFS (Delta‐Journaling File System that provides both a high level of performance and data consistency for different applications. We made three technical contributions to achieve our goal. First, to remove all storage accesses with disk cache flush operations and FUA commands, DJFS uses small‐sized NVRAM for a file system journal. Second, to reduce the access latency and space requirements of NVRAM, DJFS attempts to journal compress the differences in the modified blocks. Finally, to relieve explicit checkpointing overhead, DJFS aggressively reflects the checkpoint transactions to file system area in the unit of the specified region. Our evaluation on TPC‐C SQLite benchmark shows that, using our novel optimization schemes, DJFS outperforms Ext4 by up to 64.2 times with only 128 MB of NVRAM.

  20. GIS-based multicriteria municipal solid waste landfill suitability analysis: a review of the methodologies performed and criteria implemented.

    Science.gov (United States)

    Demesouka, O E; Vavatsikos, A P; Anagnostopoulos, K P

    2014-04-01

    Multicriteria spatial decision support systems (MC-SDSS) have emerged as an integration of the geographical information systems (GIS) and multiple criteria decision analysis (MCDA) methods. GIS-based MCDA allows the incorporation of conflicting objectives and decision maker (DM) preferences into spatial decision models. During recent decades, a variety of research articles have been published regarding the implementation of methods and/or tools in a variety of real-world case studies. The article discusses, in detail, the criteria and methods that are implemented in GIS-based landfill siting suitability analysis and especially the exclusionary and non-exclusionary criteria that can be considered when selecting sites for municipal solid waste (MSW) landfills. This paper reviews 36 seminal articles in which the evaluation of candidate landfill sites is conducted using MCDA methods. After a brief description of the main components of a MC-SDSS and the applied decision rules, the review focuses on the criteria incorporated into the decision models. The review provides a comprehensive guide to the landfill siting analysis criteria, providing details regarding the utilization methods, their decision or exclusionary nature and their monotonicity.

  1. The cognitive environment simulation as a tool for modeling human performance and reliability

    International Nuclear Information System (INIS)

    Woods, D.D.; Pople, H. Jr.

    1989-01-01

    Various studies have shown that intention errors, or cognitive error, are a major contributor to the risk of disaster. Intention formation refers to the cognitive processes by which an agent decides on what actions are appropriate to carry out (information gathering, situation assessment, diagnosis, response selection). Understanding, measuring, predicting and correcting cognitive errors depends on the answers to the question - what are difficult problems? The answer to this question defines what are risky situations from the point of view of what incidents will the human-technical system manage safely and what incidents will the human-technical system manage poorly and evolve towards negative outcomes. The authors have made progress in the development of such measuring devices through an NRC sponsored research program on cognitive modeling of operator performance. The approach is based on the demand-resource match view of human error. In this approach the difficulty of a problem depends on both the nature of the problem itself and on the resources (e.g., knowledge, plans) available to solve the problem. One can test the difficulty posed by a domain incident, given some set of resources by running the incident through a cognitive simulation that carries out the cognitive activities of a limited resource problem solver in a dynamic, uncertain, risky and highly doctrinal (pre-planned routines and procedures) world. The cognitive simulation that they have developed to do this in NPP accidents is called the Cognitive Environment Simulation (CES). They will illustrate the power of this approach by comparing the behavior of operators in variants on a simulated accident to the behavior of CES in the same accidents

  2. A proposed framework for establishing integrated cost and performance criteria for environmental technologies. A summary report to the U.S. Department of Energy

    International Nuclear Information System (INIS)

    1994-05-01

    Through an Interagency Agreement between the US Environmental Protection Agency (EPA) and the US Department of Energy (DOE), EPA directed a project to establish a suite of standard cost and performance criteria to guide the evaluation of environmental cleanup technologies for DOE sites. Ideally, these criteria would be ''generic'' in that they could be used as a basis for evaluating any cleanup technology for any DOE site. To be most useful, however, these criteria would also reflect the interests of diverse decisionmakers who influence DOE technology evaluation. The project was conducted by the National Environmental Technology Applications Center (NETAC), a nonprofit organization specializing in the development and commercialization of new and innovative environmental technologies for national and international markets. To accomplish the project objective, NETAC (1) developed a data gathering questionnaire, (2) interviewed government and industry decisionmakers, (3) identified previous criteria development efforts, (4) conducted a workshop, (5) evaluated workshop discussions, and (6) applied its five years' experience in commercializing environmental technologies to analyze project findings. The project resulted in the development of a unique and comprehensive resource or tool to enhance communication among decisionmakers. This resource, a ''Proposed Framework for Establishing Integrated Cost and Performance Criteria for Evaluating Environmental Cleanup Technologies for DOE Sites,'' offers decisionmakers a first-time comprehensive assessment of major technology evaluation issues by a decisionmaker group

  3. Improved Mechanical Performance Fracture Properties and Reliability of Radical-Cured Thermosets

    Energy Technology Data Exchange (ETDEWEB)

    Redline, Erica Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bolintineanu, Dan S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lane, J. Matthew [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stevens, Mark J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Alam, Todd M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Celina, Mathias C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    The aim of this study was to alter polymerization chemistry to improve network homogeneity in free-radical crosslinked systems. It was hypothesized that a reduction in heterogeneity of the network would lead to improved mechanical performance. Experiments and simulations were carried out to investigate the connection between polymerization chemistry, network structure and mechanical properties. Experiments were conducted on two different monomer systems - the first is a single monomer system, urethane dimethacrylate (UDMA), and the second is a two-monomer system consisting of bisphenol A glycidyl dimethacrylate (BisGMA) and triethylene glycol dimethacrylate (TEGDMA) in a ratio of 70/30 BisGMA/TEGDMA by weight. The methacrylate systems were crosslinked using traditional radical polymeriza- tion (TRP) with azobisisobutyronitrile (AIBN) or benzoyl peroxide (BPO) as an initiator; TRP systems were used as the control. The monomers were also cross-linked using activator regenerated by electron transfer atom transfer radical polymerization (ARGET ATRP) as a type of controlled radical polymerization (CRP). FTIR and DSC were used to monitor reac- tion kinetics of the systems. The networks were analyzed using NMR, DSC, X-ray diffraction (XRD), atomic force microscopy (AFM), and small angle X-ray scattering (SAXS). These techniques were employed in an attempt to quantify differences between the traditional and controlled radical polymerizations. While a quantitative methodology for characterizing net- work morphology was not established, SAXS and AFM have shown some promising initial results. Additionally, differences in mechanical behavior were observed between traditional and controlled radical polymerized thermosets in the BisGMA/TEGDMA system but not in the UDMA materials; this finding may be the result of network ductility variations between the two materials. Coarse-grained molecular dynamics simulations employing a novel model of the CRP reaction were carried out for

  4. The validity and reliability of the my jump 2 app for measuring the reactive strength index and drop jump performance.

    Science.gov (United States)

    Haynes, Tom; Bishop, Chris; Antrobus, Mark; Brazier, Jon

    2018-03-27

    This is the first study to independently assess the concurrent validity and reliability of the My Jump 2 app for measuring drop jump performance. It is also the first to evaluate the app's ability to measure the reactive strength index (RSI). Fourteen male sport science students (age: 29.5 ± 9.9 years) performed three drop jumps from 20 cm and 40 cm (totalling 84 jumps), assessed via a force platform and the My Jump 2 app. Reported metrics included reactive strength index, jump height, ground contact time, and mean power. Measurements from both devices were compared using the intraclass correlation coefficient (ICC), Pearson product moment correlation coefficient (r), Cronbach's alpha (α), coefficient of variation (CV) and BlandAltman plots. Near perfect agreement was seen between devices at 20 cm for RSI (ICC = 0.95) and contact time (ICC = 0.99) and at 40 cm for RSI (ICC = 0.98), jump height (ICC = 0.96) and contact time (ICC = 0.92); with very strong agreement seen at 20 cm for jump height (ICC = 0.80). In comparison with the force plate the app showed good validity for RSI (20 cm: r = 0.94; 40 cm; r = 0.97), jump height (20 cm: r = 0.80; 40 cm; r = 0.96) and contact time (20 cm = 0.96; 40 cm; r = 0.98). The results of the present study show that the My Jump 2 app is a valid and reliable tool for assessing drop jump performance.

  5. A critical assessment of the performance criteria in confirmatory analysis for veterinary drug residue analysis using mass spectrometric detection in selected reaction monitoring mode

    NARCIS (Netherlands)

    Berendsen, Bjorn J.A.; Meijer, Thijs; Wegh, Robin; Mol, Hans G.J.; Smyth, Wesley G.; Armstrong Hewitt, S.; Ginkel, van Leen; Nielen, Michel W.F.

    2016-01-01

    Besides the identification point system to assure adequate set-up of instrumentation, European Commission Decision 2002/657/EC includes performance criteria regarding relative ion abundances in mass spectrometry and chromatographic retention time. In confirmatory analysis, the relative abundance

  6. Alignment of University Information Technology Resources with the Malcolm Baldrige Results Criteria for Performance Excellence in Education: A Balanced Scorecard Approach

    Science.gov (United States)

    Beard, Deborah F.; Humphrey, Roberta L.

    2014-01-01

    The authors suggest using a balanced scorecard (BSC) approach to evaluate information technology (IT) resources in higher education institutions. The BSC approach illustrated is based on the performance criteria of the Malcolm Baldrige National Quality Award in Education. This article suggests areas of potential impact of IT on BSC measures in…

  7. Assessing the performance of commercial Agisoft PhotoScan software to deliver reliable data for accurate3D modelling

    Directory of Open Access Journals (Sweden)

    Jebur Ahmed

    2018-01-01

    Full Text Available 3D models delivered from digital photogrammetric techniques have massively increased and developed to meet the requirements of many applications. The reliability of these models is basically dependent on the data processing cycle and the adopted tool solution in addition to data quality. Agisoft PhotoScan is a professional image-based 3D modelling software, which seeks to create orderly, precise n 3D content from fixed images. It works with arbitrary images those qualified in both controlled and uncontrolled conditions. Following the recommendations of many users all around the globe, Agisoft PhotoScan, has become an important source to generate precise 3D data for different applications. How reliable is this data for accurate 3D modelling applications is the current question that needs an answer. Therefore; in this paper, the performance of the Agisoft PhotoScan software was assessed and analyzed to show the potential of the software for accurate 3D modelling applications. To investigate this, a study was carried out in the University of Baghdad / Al-Jaderia campus using data collected from airborne metric camera with 457m flying height. The Agisoft results show potential according to the research objective and the dataset quality following statistical and validation shape analysis.

  8. Decision making concept of risk control: integration of decision criteria, top level risk indices and plant performance indices

    International Nuclear Information System (INIS)

    Vojnovic, D.; Mavko, B.; Kozuh, M.

    1993-01-01

    A support system for risk monitoring and control is suggested. The following concepts of system elements are briefly discussed: risk curve partitioning, the reliability cost function, the multi-objective optimization model, preference assessment, safety/risk indicators, and knowledge based systems. (Z.S.) 2 figs

  9. Reliability Analysis of Adhesive Bonded Scarf Joints

    DEFF Research Database (Denmark)

    Kimiaeifar, Amin; Toft, Henrik Stensgaard; Lund, Erik

    2012-01-01

    element analysis (FEA). For the reliability analysis a design equation is considered which is related to a deterministic code-based design equation where reliability is secured by partial safety factors together with characteristic values for the material properties and loads. The failure criteria......A probabilistic model for the reliability analysis of adhesive bonded scarfed lap joints subjected to static loading is developed. It is representative for the main laminate in a wind turbine blade subjected to flapwise bending. The structural analysis is based on a three dimensional (3D) finite...... are formulated using a von Mises, a modified von Mises and a maximum stress failure criterion. The reliability level is estimated for the scarfed lap joint and this is compared with the target reliability level implicitly used in the wind turbine standard IEC 61400-1. A convergence study is performed to validate...

  10. AREVA's toolbox for long-term best performance and reliable operation of nuclear steam generators

    International Nuclear Information System (INIS)

    Drexler, Andreas; Weiss, Steffen; Caris, Neil; Stiepani, Christoph

    2015-01-01

    Long-term integrity and high performance of major plant systems and components are of uppermost importance for the successful operation of any power plant. AREVA's experience gathered with water-steam cycle chemistry treatments in more than 40 years yields the conclusion: Accumulation of corrosion products in SGs may result in local overheating and enrichment of impurities up to critical levels. This can lead to several degradation phenomena of the structural materials of the SGs. Therefore, minimization of corrosion product generation and prevention of deposit accumulation is required. The objective of AREVA's asset management program is to support operators by minimizing corrosion damage and performance losses of water-steam cycle systems and components and thereby to maximize the availability and economic performance of the plant. Such asset management program is in principle a closed cycle process. It is based on control, corrective and preventive measures. The objective of control measure is deriving a widespread assessment of the corrosion status of the steam-water cycle which yields to weak points and identifying the best suited corrective and/or preventive measures. In the subsequent steps appropriate measures which improve the current status or counteract on identified issues are identified and applied. Corrective measures, likes mechanical and/or chemical cleaning are targeting the minimization of negative influence on plant performance caused by corrosion in the steam-water cycle. Complementary to corrective measures are preventive ones, like optimization of pH strategy and AREVA's FFA technology could by applied. They are focusing on the origin of corrosion product generation. AREVA is offering a toolbox for long-term best performance and reliable operation of NPPs. (author)

  11. Investment criteria of private equity/venture capital funds and financial performance of companies before initial investment

    Directory of Open Access Journals (Sweden)

    Zbigniew Drewniak

    2013-12-01

    Full Text Available Understanding and recognizing of the investment criteria of private equity/venture capital seems to be crucial for all parties of this market. Entrepreneurs, who are looking for the capital for financing their businesses, can easier find the most proper fund and better formulate their expectations. For the funds, specifying theirs investment criteria is the reflection of the investment strategy leading to its better wording. The fund's investmentcriteriaare also importantfor investors - capital donors. First of allthey wantto knowin whattypes of assetswill be investedtheirfunds. That can help to assess the risk involved in the investment and calculate the expected rate of return. In addition topresentation ofthe investment criteriaof private equity/venture capital funds, thepaper refers to thecompany's financialsituationbefore investments. That draw the company profile, the funds are most interested to invest. The turnover, net profit, profitability ratios and liquidity were analyzed to specify this profile.

  12. A conceptual framework for a sports knee injury performance profile (SKIPP) and return to activity criteria (RTAC)

    OpenAIRE

    Logerstedt, David; Arundale, Amelia; Lynch, Andrew; Snyder-Mackler, Lynn

    2015-01-01

    ABSTRACTInjuries to the knee, including intra-articular fractures, ligamentous ruptures, and meniscal and articular cartilage lesions, are commonplace within sports. Despite advancements in surgical techniques and enhanced rehabilitation, athletes returning to cutting, pivoting, and jumping sports after a knee injury are at greater risk of sustaining a second injury. The clinical utility of objective criteria presents a decision-making challenge to ensure athletes are fully rehabilitated and ...

  13. Performance of Clinical Criteria for Screening of Possible Antiretroviral Related Mitochondrial Toxicity in HIV-Infected Children in Accra.

    Science.gov (United States)

    Langs-Barlow, Allison; Renner, Lorna; Katz, Karol; Northrup, Veronika; Paintsil, Elijah

    2013-01-01

    Mitochondrial damage is implicated in highly active antiretroviral therapy (HAART) toxicity. HIV infection also causes mitochondrial toxicity (MT). Differentiating between the two is critical for HIV management. Our objective was to test the utility of the Mitochondrial Disease Criteria (MDC) and the Enquête Périnatale Française (EPF) to screen for possible HAART related MT in HIV-infected children in Ghana. The EPF and MDC are compilations of clinical symptoms, or criteria, of MT: a (+) score indicates possible MT. We applied these criteria retrospectively to 403 charts of HIV-infected children. Of those studied, 331/403 received HAART. Comparing HAART exposed and HAART naïve children, the difference in EPF score, but not MDC, approached significance (P = 0.1). Young age at HIV diagnosis or at HAART initiation was associated with (+) EPF (P ≤ 0.01). Adherence to HAART trended toward an association with (+) EPF (P = 0.09). Exposure to nevirapine, abacavir, or didanosine increased risk of (+) EPF (OR = 3.55 (CI = 1.99-6.33), 4.76 (2.39-9.43), 4.93 (1.29-18.87)). Neither EPF nor MDC identified a significant difference between HAART exposed or naïve children regarding possible MT. However, as indicators of HAART exposure are associated with (+) EPF, it may be a candidate for prospective study of possible HAART related MT in resource-poor settings.

  14. Performance of Clinical Criteria for Screening of Possible Antiretroviral Related Mitochondrial Toxicity in HIV-Infected Children in Accra

    Directory of Open Access Journals (Sweden)

    Allison Langs-Barlow

    2013-01-01

    Full Text Available Mitochondrial damage is implicated in highly active antiretroviral therapy (HAART toxicity. HIV infection also causes mitochondrial toxicity (MT. Differentiating between the two is critical for HIV management. Our objective was to test the utility of the Mitochondrial Disease Criteria (MDC and the Enquête Périnatale Française (EPF to screen for possible HAART related MT in HIV-infected children in Ghana. The EPF and MDC are compilations of clinical symptoms, or criteria, of MT: a (+ score indicates possible MT. We applied these criteria retrospectively to 403 charts of HIV-infected children. Of those studied, 331/403 received HAART. Comparing HAART exposed and HAART naïve children, the difference in EPF score, but not MDC, approached significance (. Young age at HIV diagnosis or at HAART initiation was associated with (+ EPF (. Adherence to HAART trended toward an association with (+ EPF (. Exposure to nevirapine, abacavir, or didanosine increased risk of (+ EPF (OR = 3.55 (CI = 1.99–6.33, 4.76 (2.39–9.43, 4.93 (1.29–18.87. Neither EPF nor MDC identified a significant difference between HAART exposed or naïve children regarding possible MT. However, as indicators of HAART exposure are associated with (+ EPF, it may be a candidate for prospective study of possible HAART related MT in resource-poor settings.

  15. Reliability Engineering

    International Nuclear Information System (INIS)

    Lee, Sang Yong

    1992-07-01

    This book is about reliability engineering, which describes definition and importance of reliability, development of reliability engineering, failure rate and failure probability density function about types of it, CFR and index distribution, IFR and normal distribution and Weibull distribution, maintainability and movability, reliability test and reliability assumption in index distribution type, normal distribution type and Weibull distribution type, reliability sampling test, reliability of system, design of reliability and functionality failure analysis by FTA.

  16. Uncertainties in the Forecasted Performance of Sediment Diversions Associated with Differences Between "Optimized" Diversion Design Criteria and the Natural Crevasse-Splay Sub-Delta Life-Cycle

    Science.gov (United States)

    Brown, G.

    2017-12-01

    Sediment diversions have been proposed as a crucial component of the restoration of Coastal Louisiana. They are generally characterized as a means of creating land by mimicking natural crevasse-splay sub-delta processes. However, the criteria that are often promoted to optimize the performance of these diversions (i.e. large, sand-rich diversions into existing, degraded wetlands) are at odds with the natural processes that govern the development of crevasse-splay sub-deltas (typically sand-lean or sand-neutral diversions into open water). This is due in large part to the fact that these optimization criteria have been developed in the absence of consideration for the natural constraints associated with fundamental hydraulics: specifically, the conservation of mechanical energy. Although the implementation of the aforementioned optimization criteria have the potential to greatly increase the land-building capacity of a given diversion, the concomitant widespread inundation of the existing wetlands (an unavoidable consequence of diverting into a shallow, vegetated embayment), and the resultant stresses on existing wetland vegetation, have the potential to dramatically accelerate the loss of these existing wetlands. Hence, there are inherent uncertainties in the forecasted performance of sediment diversions that are designed according to the criteria mentioned above. This talk details the reasons for these uncertainties, using analytic and numerical model results, together with evidence from field observations and experiments. The likelihood that, in the foreseeable future, these uncertainties can be reduced, or even rationally bounded, is discussed.

  17. Comparison of performance of various tumour response criteria in assessment of regorafenib activity in advanced gastrointestinal stromal tumours after failure of imatinib and sunitinib.

    Science.gov (United States)

    Shinagare, Atul B; Jagannathan, Jyothi P; Kurra, Vikram; Urban, Trinity; Manola, Judith; Choy, Edwin; Demetri, George D; George, Suzanne; Ramaiya, Nikhil H

    2014-03-01

    To compare performance of various tumour response criteria (TRCs) in assessment of regorafenib activity in patients with advanced gastrointestinal stromal tumour (GIST) with prior failure of imatinib and sunitinib. Twenty participants in a phase II trial received oral regorafenib (median duration 47 weeks; interquartile range (IQR) 24-88) with computed tomography (CT) imaging at baseline and every two months thereafter. Tumour response was prospectively determined on using Response Evaluation Criteria in Solid Tumours (RECIST) 1.1, and retrospectively reassessed for comparison per RECIST 1.0, World Health Organization (WHO) and Choi criteria, using the same target lesions. Clinical benefit rate [CBR; complete or partial response (CR or PR) or stable disease (SD)≥16 weeks] and progression-free survival (PFS) were compared between various TRCs using kappa statistics. Performance of TRCs in predicting overall survival (OS) was compared by comparing OS in groups with progression-free intervals less than or greater than 20 weeks by each TRC using c-statistics. PR was more frequent by Choi (90%) than RECIST 1.1, RECIST 1.0 and WHO (20% each), however, CBR was similar between various TRCs (overall CBR 85-90%, 95-100% agreement between all TRC pairs). PFS per RECIST 1.0 was similar to RECIST 1.1 (median 44 weeks versus 58 weeks), and shorter for WHO (median 34 weeks) and Choi (median 24 weeks). With RECIST 1.1, RECIST 1.0 and WHO, there was moderate concordance between PFS and OS (c-statistics 0.596-0.679). Choi criteria had less favourable concordance (c-statistic 0.506). RECIST 1.1 and WHO performed somewhat better than Choi criteria as TRC for response evaluation in patients with advanced GIST after prior failure on imatinib and sunitinib. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. TheClinical Research Tool: a high-performance microdialysis-based system for reliably measuring interstitial fluid glucose concentration.

    Science.gov (United States)

    Ocvirk, Gregor; Hajnsek, Martin; Gillen, Ralph; Guenther, Arnfried; Hochmuth, Gernot; Kamecke, Ulrike; Koelker, Karl-Heinz; Kraemer, Peter; Obermaier, Karin; Reinheimer, Cornelia; Jendrike, Nina; Freckmann, Guido

    2009-05-01

    A novel microdialysis-based continuous glucose monitoring system, the so-called Clinical Research Tool (CRT), is presented. The CRT was designed exclusively for investigational use to offer high analytical accuracy and reliability. The CRT was built to avoid signal artifacts due to catheter clogging, flow obstruction by air bubbles, and flow variation caused by inconstant pumping. For differentiation between physiological events and system artifacts, the sensor current, counter electrode and polarization voltage, battery voltage, sensor temperature, and flow rate are recorded at a rate of 1 Hz. In vitro characterization with buffered glucose solutions (c(glucose) = 0 - 26 x 10(-3) mol liter(-1)) over 120 h yielded a mean absolute relative error (MARE) of 2.9 +/- 0.9% and a recorded mean flow rate of 330 +/- 48 nl/min with periodic flow rate variation amounting to 24 +/- 7%. The first 120 h in vivo testing was conducted with five type 1 diabetes subjects wearing two systems each. A mean flow rate of 350 +/- 59 nl/min and a periodic variation of 22 +/- 6% were recorded. Utilizing 3 blood glucose measurements per day and a physical lag time of 1980 s, retrospective calibration of the 10 in vivo experiments yielded a MARE value of 12.4 +/- 5.7. Clarke error grid analysis resulted in 81.0%, 16.6%, 0.8%, 1.6%, and 0% in regions A, B, C, D, and E, respectively. The CRT demonstrates exceptional reliability of system operation and very good measurement performance. The ability to differentiate between artifacts and physiological effects suggests the use of the CRT as a reference tool in clinical investigations. 2009 Diabetes Technology Society.

  19. Inter-rater Reliability for Metrics Scored in a Binary Fashion-Performance Assessment for an Arthroscopic Bankart Repair.

    Science.gov (United States)

    Gallagher, Anthony G; Ryu, Richard K N; Pedowitz, Robert A; Henn, Patrick; Angelo, Richard L

    2018-05-02

    To determine the inter-rater reliability (IRR) of a procedure-specific checklist scored in a binary fashion for the evaluation of surgical skill and whether it meets a minimum level of agreement (≥0.8 between 2 raters) required for high-stakes assessment. In a prospective randomized and blinded fashion, and after detailed assessment training, 10 Arthroscopy Association of North America Master/Associate Master faculty arthroscopic surgeons (in 5 pairs) with an average of 21 years of surgical experience assessed the video-recorded 3-anchor arthroscopic Bankart repair performance of 44 postgraduate year 4 or 5 residents from 21 Accreditation Council for Graduate Medical Education orthopaedic residency training programs from across the United States. No paired scores of resident surgeon performance evaluated by the 5 teams of faculty assessors dropped below the 0.8 IRR level (mean = 0.93; range 0.84-0.99; standard deviation = 0.035). A comparison between the 5 assessor groups with 1 factor analysis of variance showed that there was no significant difference between the groups (P = .205). Pearson's product-moment correlation coefficient revealed a strong and statistically significant negative correlation, that is, -0.856 (P fashion meet the need and can show a high (>80%) IRR. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. Support to NPP operation and maintenance technology risk management. A concept for establishing criteria and procedure for the selection of components with respect to their importance. Stage 3.1. NPP equipment reliability management

    International Nuclear Information System (INIS)

    Stvan, F.

    2003-12-01

    A proposal was developed for a procedure using the deterministic approach to the assessment of components from the operational point of view and other aspects that cannot be directly and readily quantified and of the probabilistic approach for the assessment of component importance with respect to nuclear safety. A specific PSA study performed for the Dukovany NPP was employed. The structure of the report is as follows: (1) Aspects of component selection; (2) Introductory procedure; (3) Criteria for the selection of components with respect to their importance (4) Assessing the priority of use of the assets - effect on production, safety, and profit; (5) Assessment of the risk aspect of the assets - effect on major processes; (6) Assessment of the level of use of the assets; (7) Assessment of the structure of the assets - optimal structure for maintenance in relation to the major processes; (8) Assessment of the criteria for estimating the importance of the components; (9) Probabilistic assessment of importance from the safety aspect by means of PSA; and (10) Deterministic assessment of importance from the safety aspect. (P.A.)