WorldWideScience

Sample records for reliable measurement tool

  1. Reliable tool life measurements in turning - an application to cutting fluid efficiency evaluation

    DEFF Research Database (Denmark)

    Axinte, Dragos A.; Belluco, Walter; De Chiffre, Leonardo

    2001-01-01

    The paper proposes a method to obtain reliable measurements of tool life in turning, discussing some aspects related to experimental procedure and measurement accuracy. The method (i) allows and experimental determination of the extended Taylor's equation, with a limited set of experiments and (ii......) provides efficiency evaluation. Six cutting oils, five of which formulated from vegetable basestock, were evaluated in turning. Experiments were run in a range of cutting parameters. according to a 2, 3-1 factorial design, machining AISI 316L stainless steel with coated carbide tools. Tool life...

  2. Reliability and reproducibility analysis of the Cobb angle and assessing sagittal plane by computer-assisted and manual measurement tools.

    Science.gov (United States)

    Wu, Weifei; Liang, Jie; Du, Yuanli; Tan, Xiaoyi; Xiang, Xuanping; Wang, Wanhong; Ru, Neng; Le, Jinbo

    2014-02-06

    Although many studies on reliability and reproducibility of measurement have been performed on coronal Cobb angle, few results about reliability and reproducibility are reported on sagittal alignment measurement including the pelvis. We usually use SurgimapSpine software to measure the Cobb angle in our studies; however, there are no reports till date on its reliability and reproducible measurements. Sixty-eight standard standing posteroanterior whole-spine radiographs were reviewed. Three examiners carried out the measurements independently under the settings of manual measurement on X-ray radiographies and SurgimapSpine software on the computer. Parameters measured included pelvic incidence, sacral slope, pelvic tilt, Lumbar lordosis (LL), thoracic kyphosis, and coronal Cobb angle. SPSS 16.0 software was used for statistical analyses. The means, standard deviations, intraclass and interclass correlation coefficient (ICC), and 95% confidence intervals (CI) were calculated. There was no notable difference between the two tools (P = 0.21) for the coronal Cobb angle. In the sagittal plane parameters, the ICC of intraobserver reliability for the manual measures varied from 0.65 (T2-T5 angle) to 0.95 (LL angle). Further, for SurgimapSpine tool, the ICC ranged from 0.75 to 0.98. No significant difference in intraobserver reliability was found between the two measurements (P > 0.05). As for the interobserver reliability, measurements with SurgimapSpine tool had better ICC (0.71 to 0.98 vs 0.59 to 0.96) and Pearson's coefficient (0.76 to 0.99 vs 0.60 to 0.97). The reliability of SurgimapSpine measures was significantly higher in all parameters except for the coronal Cobb angle where the difference was not significant (P > 0.05). Although the differences between the two methods are very small, the results of this study indicate that the SurgimapSpine measurement is an equivalent measuring tool to the traditional manual in coronal Cobb angle, but is advantageous in spino

  3. Reliability of the ECHOWS Tool for Assessment of Patient Interviewing Skills.

    Science.gov (United States)

    Boissonnault, Jill S; Evans, Kerrie; Tuttle, Neil; Hetzel, Scott J; Boissonnault, William G

    2016-04-01

    History taking is an important component of patient/client management. Assessment of student history-taking competency can be achieved via a standardized tool. The ECHOWS tool has been shown to be valid with modest intrarater reliability in a previous study but did not demonstrate sufficient power to definitively prove its stability. The purposes of this study were: (1) to assess the reliability of the ECHOWS tool for student assessment of patient interviewing skills and (2) to determine whether the tool discerns between novice and experienced skill levels. A reliability and construct validity assessment was conducted. Three faculty members from the United States and Australia scored videotaped histories from standardized patients taken by students and experienced clinicians from each of these countries. The tapes were scored twice, 3 to 6 weeks apart. Reliability was assessed using interclass correlation coefficients (ICCs) and repeated measures. Analysis of variance models assessed the ability of the tool to discern between novice and experienced skill levels. The ECHOWS tool showed excellent intrarater reliability (ICC [3,1]=.74-.89) and good interrater reliability (ICC [2,1]=.55) as a whole. The summary of performance (S) section showed poor interrater reliability (ICC [2,1]=.27). There was no statistical difference in performance on the tool between novice and experienced clinicians. A possible ceiling effect may occur when standardized patients are not coached to provide complex and obtuse responses to interviewer questions. Variation in familiarity with the ECHOWS tool and in use of the online training may have influenced scoring of the S section. The ECHOWS tool demonstrates excellent intrarater reliability and moderate interrater reliability. Sufficient training with the tool prior to student assessment is recommended. The S section must evolve in order to provide a more discerning measure of interviewing skills. © 2016 American Physical Therapy

  4. Is a sphygmomanometer a valid and reliable tool to measure the isometric strength of hip muscles? A systematic review.

    Science.gov (United States)

    Toohey, Liam Anthony; De Noronha, Marcos; Taylor, Carolyn; Thomas, James

    2015-02-01

    Muscle strength measurement is a key component of physiotherapists' assessment and is frequently used as an outcome measure. A sphygmomanometer is an instrument commonly used to measure blood pressure that can be potentially used as a tool to assess isometric muscle strength. To systematically review the evidence on the reliability and validity of a sphygmomanometer for measuring isometric strength of hip muscles. A literature search was conducted across four databases. Studies were eligible if they presented data on reliability and/or validity, used a sphygmomanometer to measure isometric muscle strength of the hip region, and were peer reviewed. The individual studies were evaluated for quality using a standardized critical appraisal tool. A total of 644 articles were screened for eligibility, with five articles chosen for inclusion. The use of a sphygmomanometer to objectively assess isometric muscle strength of the hip muscles appears to be reliable with intraclass correlation coefficient values ranging from 0.66 to 0.94 in elderly and young populations. No studies were identified that have assessed the validity of a sphygmomanometer. The sphygmomanometer appears to be reliable for assessment of isometric muscle strength around the hip joint, but further research is warranted to establish its validity.

  5. A clinical tool to measure plagiocephaly in infants using a flexicurve: a reliability study

    Directory of Open Access Journals (Sweden)

    Leung A

    2013-10-01

    % CI 0.897–0.983; and for interrater reliability, ICCdf17 = 0.874 (95% CI 0.696–0.951. Conclusion: The modified cranial vault asymmetry index using flexicurve in measuring plagiocephaly is a reliable assessment tool. It is economical and efficient for use in clinical settings. Keywords: plagiocephaly, modified cranial vault asymmetry index, infant, community health, reliability

  6. A clinical assessment tool used for physiotherapy students--is it reliable?

    Science.gov (United States)

    Lewis, Lucy K; Stiller, Kathy; Hardy, Frances

    2008-01-01

    Educational institutions providing professional programs such as physiotherapy must provide high-quality student assessment procedures. To ensure that assessment is consistent, assessment tools should have an acceptable level of reliability. There is a paucity of research evaluating the reliability of clinical assessment tools used for physiotherapy students. This study evaluated the inter- and intrarater reliability of an assessment tool used for physiotherapy students during a clinical placement. Five clinical educators and one academic participated in the study. Each rater independently marked 22 student written assessments that had been completed by students after viewing a videotaped patient physiotherapy assessment. The raters repeated the marking process 7 weeks later, with the assessments provided in a randomised order. The interrater reliability (Intraclass Correlation Coefficient) for the total scores was 0.32, representing a poor level of reliability. A high level of intrarater reliability (percentage agreement) was found for the clinical educators, with a difference in section scores of one mark or less on 93.4% of occasions. Further research should be undertaken to reevaluate the reliability of this clinical assessment tool following training. The reliability of clinical assessment tools used in other areas of physiotherapy education should be formally measured rather than assumed.

  7. Suprahyoid Muscle Complex: A Reliable Neural Assessment Tool For Dysphagia?

    DEFF Research Database (Denmark)

    Kothari, Mohit; Stubbs, Peter William; Pedersen, Asger Roer

    be a non-invasive reliable neural assessment tool for patients with dysphagia. Objective: To investigate the possibility of using the suprahyoid muscle complex (SMC) using surface electromyography (sEMG) to assess changes to neural pathways by determining the reliability of measurements in healthy...

  8. Reliability concepts applied to cutting tool change time

    Energy Technology Data Exchange (ETDEWEB)

    Patino Rodriguez, Carmen Elena, E-mail: cpatino@udea.edu.c [Department of Industrial Engineering, University of Antioquia, Medellin (Colombia); Department of Mechatronics and Mechanical Systems, Polytechnic School, University of Sao Paulo, Sao Paulo (Brazil); Francisco Martha de Souza, Gilberto [Department of Mechatronics and Mechanical Systems, Polytechnic School, University of Sao Paulo, Sao Paulo (Brazil)

    2010-08-15

    This paper presents a reliability-based analysis for calculating critical tool life in machining processes. It is possible to determine the running time for each tool involved in the process by obtaining the operations sequence for the machining procedure. Usually, the reliability of an operation depends on three independent factors: operator, machine-tool and cutting tool. The reliability of a part manufacturing process is mainly determined by the cutting time for each job and by the sequence of operations, defined by the series configuration. An algorithm is presented to define when the cutting tool must be changed. The proposed algorithm is used to evaluate the reliability of a manufacturing process composed of turning and drilling operations. The reliability of the turning operation is modeled based on data presented in the literature, and from experimental results, a statistical distribution of drilling tool wear was defined, and the reliability of the drilling process was modeled.

  9. Reliability concepts applied to cutting tool change time

    International Nuclear Information System (INIS)

    Patino Rodriguez, Carmen Elena; Francisco Martha de Souza, Gilberto

    2010-01-01

    This paper presents a reliability-based analysis for calculating critical tool life in machining processes. It is possible to determine the running time for each tool involved in the process by obtaining the operations sequence for the machining procedure. Usually, the reliability of an operation depends on three independent factors: operator, machine-tool and cutting tool. The reliability of a part manufacturing process is mainly determined by the cutting time for each job and by the sequence of operations, defined by the series configuration. An algorithm is presented to define when the cutting tool must be changed. The proposed algorithm is used to evaluate the reliability of a manufacturing process composed of turning and drilling operations. The reliability of the turning operation is modeled based on data presented in the literature, and from experimental results, a statistical distribution of drilling tool wear was defined, and the reliability of the drilling process was modeled.

  10. Measurement properties of tools measuring mental health knowledge: a systematic review.

    Science.gov (United States)

    Wei, Yifeng; McGrath, Patrick J; Hayden, Jill; Kutcher, Stan

    2016-08-23

    Mental health literacy has received great attention recently to improve mental health knowledge, decrease stigma and enhance help-seeking behaviors. We conducted a systematic review to critically appraise the qualities of studies evaluating the measurement properties of mental health knowledge tools and the quality of included measurement properties. We searched PubMed, PsycINFO, EMBASE, CINAHL, the Cochrane Library, and ERIC for studies addressing psychometrics of mental health knowledge tools and published in English. We applied the COSMIN checklist to assess the methodological quality of each study as "excellent", "good", "fair", or "indeterminate". We ranked the level of evidence of the overall quality of each measurement property across studies as "strong", "moderate", "limited", "conflicting", or "unknown". We identified 16 mental health knowledge tools in 17 studies, addressing reliability, validity, responsiveness or measurement errors. The methodological quality of included studies ranged from "poor" to "excellent" including 6 studies addressing the content validity, internal consistency or structural validity demonstrating "excellent" quality. We found strong evidence of the content validity or internal consistency of 6 tools; moderate evidence of the internal consistency, the content validity or the reliability of 8 tools; and limited evidence of the reliability, the structural validity, the criterion validity, or the construct validity of 12 tools. Both the methodological qualities of included studies and the overall evidence of measurement properties are mixed. Based on the current evidence, we recommend that researchers consider using tools with measurement properties of strong or moderate evidence that also reached the threshold for positive ratings according to COSMIN checklist.

  11. Reliability of Lactation Assessment Tools Applied to Overweight and Obese Women.

    Science.gov (United States)

    Chapman, Donna J; Doughty, Katherine; Mullin, Elizabeth M; Pérez-Escamilla, Rafael

    2016-05-01

    The interrater reliability of lactation assessment tools has not been evaluated in overweight/obese women. This study aimed to compare the interrater reliability of 4 lactation assessment tools in this population. A convenience sample of 45 women (body mass index > 27.0) was videotaped while breastfeeding (twice daily on days 2, 4, and 7 postpartum). Three International Board Certified Lactation Consultants independently rated each videotaped session using 4 tools (Infant Breastfeeding Assessment Tool [IBFAT], modified LATCH [mLATCH], modified Via Christi [mVC], and Riordan's Tool [RT]). For each day and tool, we evaluated interrater reliability with 1-way repeated-measures analyses of variance, intraclass correlation coefficients (ICCs), and percentage absolute agreement between raters. Analyses of variance showed significant differences between raters' scores on day 2 (all scales) and day 7 (RT). Intraclass correlation coefficient values reflected good (mLATCH) to excellent reliability (IBFAT, mVC, and RT) on days 2 and 7. All day 4 ICCs reflected good reliability. The ICC for mLATCH was significantly lower than all others on day 2 and was significantly lower than IBFAT (day 7). Percentage absolute interrater agreement for scale components ranged from 31% (day 2: observable swallowing, RT) to 92% (day 7: IBFAT, fixing; and mVC, latch time). Swallowing scores on all scales had the lowest levels of interrater agreement (31%-64%). We demonstrated differences in the interrater reliability of 4 lactation assessment tools when applied to overweight/obese women, with the lowest values observed on day 4. Swallowing assessment was particularly unreliable. Researchers and clinicians using these scales should be aware of the differences in their psychometric behavior. © The Author(s) 2015.

  12. The reliability analysis of cutting tools in the HSM processes

    OpenAIRE

    W.S. Lin

    2008-01-01

    Purpose: This article mainly describe the reliability of the cutting tools in the high speed turning by normaldistribution model.Design/methodology/approach: A series of experimental tests have been done to evaluate the reliabilityvariation of the cutting tools. From experimental results, the tool wear distribution and the tool life are determined,and the tool life distribution and the reliability function of cutting tools are derived. Further, the reliability ofcutting tools at anytime for h...

  13. A tale of two tools: Reliability and feasibility of social media measurement tools examining e-cigarette twitter mentions

    Directory of Open Access Journals (Sweden)

    Amelia Burke-Garcia

    Full Text Available Given 70% of Americans are seeking health information online, social media are becoming main sources of health-related information and discussions. Specifically, compounding rising trends in use of e-cigarettes in the US, there has been a rapid rise in e-cigarette marketing – much of which is happening on social media. Public health professionals seeking to understand consumer knowledge, attitudes and beliefs about e-cigarettes should consider analyzing social media data and to do so, there are numerous free and paid tools available. However, each uses different sources and processes, which makes data validation challenging. This exploratory study sought to understand the reliability and feasibility of two social media data tools analyzing e-cigarette tweets. Twitter mentions were pulled from two different industry standard tools (GNIP and Radian6 and data were evaluated on six measures, e.g. Cost, Feasibility, Ease of Use, Poster Type (individual/organization, Context (tweet content analysis, and Valence (positive/negative. Findings included similarities amongst the data sets in terms of the content themes but differences in cost and ease of use of the tools themselves. These findings align with prior research, notably that e-cigarette marketing tweets are most common and public health-related content is noticeably absent. Findings from this exploratory study can inform future social media studies as well as communication campaigns seeking to address the emerging issue of e-cigarette use. Keywords: E-cigarettes, Vaping, Twitter, Tweets, Social media

  14. A reliability analysis tool for SpaceWire network

    Science.gov (United States)

    Zhou, Qiang; Zhu, Longjiang; Fei, Haidong; Wang, Xingyou

    2017-04-01

    A SpaceWire is a standard for on-board satellite networks as the basis for future data-handling architectures. It is becoming more and more popular in space applications due to its technical advantages, including reliability, low power and fault protection, etc. High reliability is the vital issue for spacecraft. Therefore, it is very important to analyze and improve the reliability performance of the SpaceWire network. This paper deals with the problem of reliability modeling and analysis with SpaceWire network. According to the function division of distributed network, a reliability analysis method based on a task is proposed, the reliability analysis of every task can lead to the system reliability matrix, the reliability result of the network system can be deduced by integrating these entire reliability indexes in the matrix. With the method, we develop a reliability analysis tool for SpaceWire Network based on VC, where the computation schemes for reliability matrix and the multi-path-task reliability are also implemented. By using this tool, we analyze several cases on typical architectures. And the analytic results indicate that redundancy architecture has better reliability performance than basic one. In practical, the dual redundancy scheme has been adopted for some key unit, to improve the reliability index of the system or task. Finally, this reliability analysis tool will has a directive influence on both task division and topology selection in the phase of SpaceWire network system design.

  15. Towards early software reliability prediction for computer forensic tools (case study).

    Science.gov (United States)

    Abu Talib, Manar

    2016-01-01

    Versatility, flexibility and robustness are essential requirements for software forensic tools. Researchers and practitioners need to put more effort into assessing this type of tool. A Markov model is a robust means for analyzing and anticipating the functioning of an advanced component based system. It is used, for instance, to analyze the reliability of the state machines of real time reactive systems. This research extends the architecture-based software reliability prediction model for computer forensic tools, which is based on Markov chains and COSMIC-FFP. Basically, every part of the computer forensic tool is linked to a discrete time Markov chain. If this can be done, then a probabilistic analysis by Markov chains can be performed to analyze the reliability of the components and of the whole tool. The purposes of the proposed reliability assessment method are to evaluate the tool's reliability in the early phases of its development, to improve the reliability assessment process for large computer forensic tools over time, and to compare alternative tool designs. The reliability analysis can assist designers in choosing the most reliable topology for the components, which can maximize the reliability of the tool and meet the expected reliability level specified by the end-user. The approach of assessing component-based tool reliability in the COSMIC-FFP context is illustrated with the Forensic Toolkit Imager case study.

  16. TWO CRITERIA FOR GOOD MEASUREMENTS IN RESEARCH: VALIDITY AND RELIABILITY

    Directory of Open Access Journals (Sweden)

    Haradhan Kumar Mohajan

    2017-12-01

    Full Text Available Reliability and validity are two most important and fundamental features in the evaluation of any measurement instrument or toll for a good research. The purpose of this research is to discuss the validity and reliability of measurement instruments that are used in research. Validity concerns what an instrument measures, and how well it does so. Reliability concerns the faith that one can have in the data obtained from use of an instrument, that is, the degree to which any measuring tool controls for random error. An attempt has been taken here to review the reliability and validity, and threat to them in some details.

  17. Reliability of a computer software angle tool for measuring spine and pelvic flexibility during the sit-and-reach test.

    Science.gov (United States)

    Mier, Constance M; Shapiro, Belinda S

    2013-02-01

    The purpose of this study was to determine the reliability of a computer software angle tool that measures thoracic (T), lumbar (L), and pelvic (P) angles as a means of evaluating spine and pelvic flexibility during the sit-and-reach (SR) test. Thirty adults performed the SR twice on separate days. The SR test was captured on video and later analyzed for T, L, and P angles using the computer software angle tool. During the test, 3 markers were placed over T1, T12, and L5 vertebrae to identify T, L, and P angles. Intraclass correlation coefficient (ICC) indicated a very high internal consistency (between trials) for T, L, and P angles (0.95-0.99); thus, the average of trials was used for test-retest (between days) reliability. Mean (±SD) values did not differ between days for T (51.0 ± 14.3 vs. 52.3 ± 16.2°), L (23.9 ± 7.1 vs. 23.0 ± 6.9°), or P (98.4 ± 15.6 vs. 98.3 ± 14.7°) angles. Test-retest reliability (ICC) was high for T (0.96) and P (0.97) angles and moderate for L angle (0.84). Both intrarater and interrater reliabilities were high for T (0.95, 0.94) and P (0.97, 0.97) angles and moderate for L angle (0.87, 0.82). Thus, the computer software angle tool is a highly objective method for assessing spine and pelvic flexibility during a video-captured SR test.

  18. Reliability and criterion validity of measurements using a smart phone-based measurement tool for the transverse rotation angle of the pelvis during single-leg lifting.

    Science.gov (United States)

    Jung, Sung-Hoon; Kwon, Oh-Yun; Jeon, In-Cheol; Hwang, Ui-Jae; Weon, Jong-Hyuck

    2018-01-01

    The purposes of this study were to determine the intra-rater test-retest reliability of a smart phone-based measurement tool (SBMT) and a three-dimensional (3D) motion analysis system for measuring the transverse rotation angle of the pelvis during single-leg lifting (SLL) and the criterion validity of the transverse rotation angle of the pelvis measurement using SBMT compared with a 3D motion analysis system (3DMAS). Seventeen healthy volunteers performed SLL with their dominant leg without bending the knee until they reached a target placed 20 cm above the table. This study used a 3DMAS, considered the gold standard, to measure the transverse rotation angle of the pelvis to assess the criterion validity of the SBMT measurement. Intra-rater test-retest reliability was determined using the SBMT and 3DMAS using intra-class correlation coefficient (ICC) [3,1] values. The criterion validity of the SBMT was assessed with ICC [3,1] values. Both the 3DMAS (ICC = 0.77) and SBMT (ICC = 0.83) showed excellent intra-rater test-retest reliability in the measurement of the transverse rotation angle of the pelvis during SLL in a supine position. Moreover, the SBMT showed an excellent correlation with the 3DMAS (ICC = 0.99). Measurement of the transverse rotation angle of the pelvis using the SBMT showed excellent reliability and criterion validity compared with the 3DMAS.

  19. STARS software tool for analysis of reliability and safety

    International Nuclear Information System (INIS)

    Poucet, A.; Guagnini, E.

    1989-01-01

    This paper reports on the STARS (Software Tool for the Analysis of Reliability and Safety) project aims at developing an integrated set of Computer Aided Reliability Analysis tools for the various tasks involved in systems safety and reliability analysis including hazard identification, qualitative analysis, logic model construction and evaluation. The expert system technology offers the most promising perspective for developing a Computer Aided Reliability Analysis tool. Combined with graphics and analysis capabilities, it can provide a natural engineering oriented environment for computer assisted reliability and safety modelling and analysis. For hazard identification and fault tree construction, a frame/rule based expert system is used, in which the deductive (goal driven) reasoning and the heuristic, applied during manual fault tree construction, is modelled. Expert system can explain their reasoning so that the analyst can become aware of the why and the how results are being obtained. Hence, the learning aspect involved in manual reliability and safety analysis can be maintained and improved

  20. Validity and reliability of food security measures.

    Science.gov (United States)

    Cafiero, Carlo; Melgar-Quiñonez, Hugo R; Ballard, Terri J; Kepple, Anne W

    2014-12-01

    This paper reviews some of the existing food security indicators, discussing the validity of the underlying concept and the expected reliability of measures under reasonably feasible conditions. The main objective of the paper is to raise awareness on existing trade-offs between different qualities of possible food security measurement tools that must be taken into account when such tools are proposed for practical application, especially for use within an international monitoring framework. The hope is to provide a timely, useful contribution to the process leading to the definition of a food security goal and the associated monitoring framework within the post-2015 Development Agenda. © 2014 New York Academy of Sciences.

  1. Development, Construct Validity, and Reliability of the Questionnaire on Infant Feeding: A Tool for Measuring Contemporary Infant-Feeding Behaviors.

    Science.gov (United States)

    O'Sullivan, Elizabeth J; Rasmussen, Kathleen M

    2017-12-01

    The breastfeeding surveillance tool in the United States, the National Immunization Survey, considers the maternal-infant dyad to be breastfeeding for as long as the infant consumes human milk (HM). However, many infants consume at least some HM from a bottle, which can lead to health outcomes different from those for at-the-breast feeding. Our aim was to develop a construct-valid questionnaire that categorizes infants by nutrition source, that is, own mother's HM, another mother's HM, infant formula, or other and feeding mode, that is, at the breast or from a bottle, and test the reliability of this questionnaire. The Questionnaire on Infant Feeding was developed through a literature review and modified based on qualitative research. Construct validity was assessed through cognitive interviews and a test-retest reliability study was conducted among mothers who completed the questionnaire twice, 1 month apart. Cognitive interviews were conducted with ten mothers from upstate New York between September and December 2014. A test-retest reliability study was conducted among 44 mothers from across the United States between March and May 2015. Equivalence of questions with continuous responses about the timing of starting and stopping various behaviors and the agreement between responses to questions with categorical responses on the two questionnaires completed 1 month apart. Reliability was assessed using paired-equivalence tests for questions about the timing of starting and stopping behaviors and weighted Cohen's κ for questions about the frequency and intensity of behaviors. Reliability of the Questionnaire on Infant Feeding was moderately high among mothers of infants aged 19 to 35 months, with most questions about the timing of starting and stopping behaviors equivalent to within 1 month. Weighted Cohen's κ for categorical questions indicated substantial agreement. The Questionnaire on Infant Feeding is a construct-valid tool to measure duration, intensity

  2. Quantitative measurement of hypertrophic scar: interrater reliability and concurrent validity.

    Science.gov (United States)

    Nedelec, Bernadette; Correa, José A; Rachelska, Grazyna; Armour, Alexis; LaSalle, Léo

    2008-01-01

    Research into the pathophysiology and treatment of hypertrophic scar (HSc) remains limited by the heterogeneity of scar and the imprecision with which its severity is measured. The objective of this study was to test the interrater reliability and concurrent validity of the Cutometer measurement of elasticity, the Mexameter measurement of erythema and pigmentation, and total thickness measure of the DermaScan C relative to the modified Vancouver Scar Scale (mVSS) in patient-matched normal skin, normal scar, and HSc. Three independent investigators evaluated 128 sites (severe HSc, moderate or mild HSc, donor site, and normal skin) on 32 burn survivors using all of the above measurement tools. The intraclass correlation coefficient, which was used to measure interrater reliability, reflects the inherent amount of error in the measure and is considered acceptable when it is >0.75. Interrater reliability of the totals of the height, pliability, and vascularity subscales of the mVSS fell below the acceptable limit ( congruent with0.50). The individual subscales of the mVSS fell well below the acceptable level (0.89) for each study site with the exception of severe scar. Mexameter and DermaScan C reliability measurements were acceptable for all sites (>0.82). Concurrent validity correlations with the mVSS were significant except for the comparison of the mVSS pliability subscale and the Cutometer maximum deformation measure comparison in severe scar. In conclusion, the Mexameter and DermaScan C measurements of scar color and thickness of all sites, as well as the Cutometer measurement of elasticity in all but the most severe scars shows high interrater reliability. Their significant concurrent validity with the mVSS confirms that these tools are measuring the same traits as the mVSS, and in a more objective way.

  3. Seeking high reliability in primary care: Leadership, tools, and organization.

    Science.gov (United States)

    Weaver, Robert R

    2015-01-01

    Leaders in health care increasingly recognize that improving health care quality and safety requires developing an organizational culture that fosters high reliability and continuous process improvement. For various reasons, a reliability-seeking culture is lacking in most health care settings. Developing a reliability-seeking culture requires leaders' sustained commitment to reliability principles using key mechanisms to embed those principles widely in the organization. The aim of this study was to examine how key mechanisms used by a primary care practice (PCP) might foster a reliability-seeking, system-oriented organizational culture. A case study approach was used to investigate the PCP's reliability culture. The study examined four cultural artifacts used to embed reliability-seeking principles across the organization: leadership statements, decision support tools, and two organizational processes. To decipher their effects on reliability, the study relied on observations of work patterns and the tools' use, interactions during morning huddles and process improvement meetings, interviews with clinical and office staff, and a "collective mindfulness" questionnaire. The five reliability principles framed the data analysis. Leadership statements articulated principles that oriented the PCP toward a reliability-seeking culture of care. Reliability principles became embedded in the everyday discourse and actions through the use of "problem knowledge coupler" decision support tools and daily "huddles." Practitioners and staff were encouraged to report unexpected events or close calls that arose and which often initiated a formal "process change" used to adjust routines and prevent adverse events from recurring. Activities that foster reliable patient care became part of the taken-for-granted routine at the PCP. The analysis illustrates the role leadership, tools, and organizational processes play in developing and embedding a reliable-seeking culture across an

  4. TheClinical Research Tool: a high-performance microdialysis-based system for reliably measuring interstitial fluid glucose concentration.

    Science.gov (United States)

    Ocvirk, Gregor; Hajnsek, Martin; Gillen, Ralph; Guenther, Arnfried; Hochmuth, Gernot; Kamecke, Ulrike; Koelker, Karl-Heinz; Kraemer, Peter; Obermaier, Karin; Reinheimer, Cornelia; Jendrike, Nina; Freckmann, Guido

    2009-05-01

    A novel microdialysis-based continuous glucose monitoring system, the so-called Clinical Research Tool (CRT), is presented. The CRT was designed exclusively for investigational use to offer high analytical accuracy and reliability. The CRT was built to avoid signal artifacts due to catheter clogging, flow obstruction by air bubbles, and flow variation caused by inconstant pumping. For differentiation between physiological events and system artifacts, the sensor current, counter electrode and polarization voltage, battery voltage, sensor temperature, and flow rate are recorded at a rate of 1 Hz. In vitro characterization with buffered glucose solutions (c(glucose) = 0 - 26 x 10(-3) mol liter(-1)) over 120 h yielded a mean absolute relative error (MARE) of 2.9 +/- 0.9% and a recorded mean flow rate of 330 +/- 48 nl/min with periodic flow rate variation amounting to 24 +/- 7%. The first 120 h in vivo testing was conducted with five type 1 diabetes subjects wearing two systems each. A mean flow rate of 350 +/- 59 nl/min and a periodic variation of 22 +/- 6% were recorded. Utilizing 3 blood glucose measurements per day and a physical lag time of 1980 s, retrospective calibration of the 10 in vivo experiments yielded a MARE value of 12.4 +/- 5.7. Clarke error grid analysis resulted in 81.0%, 16.6%, 0.8%, 1.6%, and 0% in regions A, B, C, D, and E, respectively. The CRT demonstrates exceptional reliability of system operation and very good measurement performance. The ability to differentiate between artifacts and physiological effects suggests the use of the CRT as a reference tool in clinical investigations. 2009 Diabetes Technology Society.

  5. The PRECIS-2 tool has good interrater reliability and modest discriminant validity.

    Science.gov (United States)

    Loudon, Kirsty; Zwarenstein, Merrick; Sullivan, Frank M; Donnan, Peter T; Gágyor, Ildikó; Hobbelen, Hans J S M; Althabe, Fernando; Krishnan, Jerry A; Treweek, Shaun

    2017-08-01

    PRagmatic Explanatory Continuum Indicator Summary (PRECIS)-2 is a tool that could improve design insight for trialists. Our aim was to validate the PRECIS-2 tool, unlike its predecessor, testing the discriminant validity and interrater reliability. Over 80 international trialists, methodologists, clinicians, and policymakers created PRECIS-2 helping to ensure face validity and content validity. The interrater reliability of PRECIS-2 was measured using 19 experienced trialists who used PRECIS-2 to score a diverse sample of 15 randomized controlled trial protocols. Discriminant validity was tested with two raters to independently determine if the trial protocols were more pragmatic or more explanatory, with scores from the 19 raters for the 15 trials as predictors of pragmatism. Interrater reliability was generally good, with seven of nine domains having an intraclass correlation coefficient over 0.65. Flexibility (adherence) and recruitment had wide confidence intervals, but raters found these difficult to rate and wanted more information. Each of the nine PRECIS-2 domains could be used to differentiate between trials taking more pragmatic or more explanatory approaches with better than chance discrimination for all domains. We have assessed the validity and reliability of PRECIS-2. An elaboration study and web site provide guidance to help future users of the tool which is continuing to be tested by trial teams, systematic reviewers, and funders. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. A Turkish Version of the Critical-Care Pain Observation Tool: Reliability and Validity Assessment.

    Science.gov (United States)

    Aktaş, Yeşim Yaman; Karabulut, Neziha

    2017-08-01

    The study aim was to evaluate the validity and reliability of the Critical-Care Pain Observation Tool in critically ill patients. A repeated measures design was used for the study. A convenience sample of 66 patients who had undergone open-heart surgery in the cardiovascular surgery intensive care unit in Ordu, Turkey, was recruited for the study. The patients were evaluated by using the Critical-Care Pain Observation Tool at rest, during a nociceptive procedure (suctioning), and 20 minutes after the procedure while they were conscious and intubated after surgery. The Turkish version of the Critical-Care Pain Observation Tool has shown statistically acceptable levels of validity and reliability. Inter-rater reliability was supported by moderate-to-high-weighted κ coefficients (weighted κ coefficient = 0.55 to 1.00). For concurrent validity, significant associations were found between the scores on the Critical-Care Pain Observation Tool and the Behavioral Pain Scale scores. Discriminant validity was also supported by higher scores during suctioning (a nociceptive procedure) versus non-nociceptive procedures. The internal consistency of the Critical-Care Pain Observation Tool was 0.72 during a nociceptive procedure and 0.71 during a non-nociceptive procedure. The validity and reliability of the Turkish version of the Critical-Care Pain Observation Tool was determined to be acceptable for pain assessment in critical care, especially for patients who cannot communicate verbally. Copyright © 2016 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  7. Reliability and criterion-related validity testing (construct) of the Endotracheal Suction Assessment Tool (ESAT©).

    Science.gov (United States)

    Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne

    2018-05-01

    To establish criterion-related construct validity and test-retest reliability for the Endotracheal Suction Assessment Tool© (ESAT©). Endotracheal tube suction performed in children can significantly affect clinical stability. Previously identified clinical indicators for endotracheal tube suction were used as criteria when designing the ESAT©. Content validity was reported previously. The final stages of psychometric testing are presented. Observational testing was used to measure construct validity and determine whether the ESAT© could guide "inexperienced" paediatric intensive care nurses' decision-making regarding endotracheal tube suction. Test-retest reliability of the ESAT© was performed at two time points. The researchers and paediatric intensive care nurse "experts" developed 10 hypothetical clinical scenarios with predetermined endotracheal tube suction outcomes. "Experienced" (n = 12) and "inexperienced" (n = 14) paediatric intensive care nurses were presented with the scenarios and the ESAT© guiding decision-making about whether to perform endotracheal tube suction for each scenario. Outcomes were compared with those predetermined by the "experts" (n = 9). Test-retest reliability of the ESAT© was measured at two consecutive time points (4 weeks apart) with "experienced" and "inexperienced" paediatric intensive care nurses using the same scenarios and tool to guide decision-making. No differences were observed between endotracheal tube suction decisions made by "experts" (n = 9), "inexperienced" (n = 14) and "experienced" (n = 12) nurses confirming the tool's construct validity. No differences were observed between groups for endotracheal tube suction decisions at T1 and T2. Criterion-related construct validity and test-retest reliability of the ESAT© were demonstrated. Further testing is recommended to confirm reliability in the clinical setting with the "inexperienced" nurse to guide decision-making related to endotracheal tube

  8. Application-Driven Reliability Measures and Evaluation Tool for Fault-Tolerant Real-Time Systems

    National Research Council Canada - National Science Library

    Krishna, C

    2001-01-01

    .... The measure combines graphic-theoretic concepts in evaluating the underlying reliability of the network and other means to evaluate the ability of the network to support interprocessor traffic...

  9. Measuring maternal satisfaction with maternity care: A systematic integrative review: What is the most appropriate, reliable and valid tool that can be used to measure maternal satisfaction with continuity of maternity care?

    Science.gov (United States)

    Perriman, Noelyn; Davis, Deborah

    2016-06-01

    The objective of this systematic integrative review is to identify, summarise and communicate the findings of research relating to tools that measure maternal satisfaction with continuity of maternity care models. In so doing the most appropriate, reliable and valid tool that can be used to measure maternal satisfaction with continuity of maternity care will be determined. A systematic integrative review of published and unpublished literature was undertaken using selected databases. Research papers were included if they measured maternal satisfaction in a continuity model of maternity care, were published in English after 1999 and if they included (or made available) the instrument used to measure satisfaction. Six hundred and thirty two unique papers were identified and after applying the selection criteria, four papers were included in the review. Three of these originated in Australia and one in Canada. The primary focus of all papers was not on the development of a tool to measure maternal satisfaction but on the comparison of outcomes in different models of care. The instruments developed varied in terms of the degree to which they were tested for validity and reliability. Women's satisfaction with maternity services is an important measure of quality. Most satisfaction surveys in maternity appear to reflect fragmented models of care though continuity of care models are increasing in line with the evidence demonstrating their effectiveness. It is important that robust tools are developed for this context and that there is some consistency in the way this is measured and reported for the purposes of benchmarking and quality improvement. Copyright © 2016 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  10. Evaluating the reliability of an injury prevention screening tool: Test-retest study.

    Science.gov (United States)

    Gittelman, Michael A; Kincaid, Madeline; Denny, Sarah; Wervey Arnold, Melissa; FitzGerald, Michael; Carle, Adam C; Mara, Constance A

    2016-10-01

    A standardized injury prevention (IP) screening tool can identify family risks and allow pediatricians to address behaviors. To assess behavior changes on later screens, the tool must be reliable for an individual and ideally between household members. Little research has examined the reliability of safety screening tool questions. This study utilized test-retest reliability of parent responses on an existing IP questionnaire and also compared responses between household parents. Investigators recruited parents of children 0 to 1 year of age during admission to a tertiary care children's hospital. When both parents were present, one was chosen as the "primary" respondent. Primary respondents completed the 30-question IP screening tool after consent, and they were re-screened approximately 4 hours later to test individual reliability. The "second" parent, when present, only completed the tool once. All participants received a 10-dollar gift card. Cohen's Kappa was used to estimate test-retest reliability and inter-rater agreement. Standard test-retest criteria consider Kappa values: 0.0 to 0.40 poor to fair, 0.41 to 0.60 moderate, 0.61 to 0.80 substantial, and 0.81 to 1.00 as almost perfect reliability. One hundred five families participated, with five lost to follow-up. Thirty-two (30.5%) parent dyads completed the tool. Primary respondents were generally mothers (88%) and Caucasian (72%). Test-retest of the primary respondents showed their responses to be almost perfect; average 0.82 (SD = 0.13, range 0.49-1.00). Seventeen questions had almost perfect test-retest reliability and 11 had substantial reliability. However, inter-rater agreement between household members for 12 objective questions showed little agreement between responses; inter-rater agreement averaged 0.35 (SD = 0.34, range -0.19-1.00). One question had almost perfect inter-rater agreement and two had substantial inter-rater agreement. The IP screening tool used by a single individual had excellent

  11. Enhancement of the reliability of automated ultrasonic inspections using tools of quantitative NDT

    International Nuclear Information System (INIS)

    Kappes, W.; Baehr, W.; Kroening, M.; Schmitz, V.

    1994-01-01

    To achieve reliable test results from automated ultrasonic inspection of safety related components, optimization and integral consideration of the various inspection stages - inspection planning, inspection performance and evaluation of results - are indispensable. For this purpose, a large potential of methods is available: advanced measurement techniques, mathematical-numerical modelling processes, artificial intelligence tools, data bases and CAD systems. The potential inherent in these methods to enhance inspection reliability is outlined by way of different applications. (orig.) [de

  12. The Outdoor MEDIA DOT: The development and inter-rater reliability of a tool designed to measure food and beverage outlets and outdoor advertising.

    Science.gov (United States)

    Poulos, Natalie S; Pasch, Keryn E

    2015-07-01

    Few studies of the food environment have collected primary data, and even fewer have reported reliability of the tool used. This study focused on the development of an innovative electronic data collection tool used to document outdoor food and beverage (FB) advertising and establishments near 43 middle and high schools in the Outdoor MEDIA Study. Tool development used GIS based mapping, an electronic data collection form on handheld devices, and an easily adaptable interface to efficiently collect primary data within the food environment. For the reliability study, two teams of data collectors documented all FB advertising and establishments within one half-mile of six middle schools. Inter-rater reliability was calculated overall and by advertisement or establishment category using percent agreement. A total of 824 advertisements (n=233), establishment advertisements (n=499), and establishments (n=92) were documented (range=8-229 per school). Overall inter-rater reliability of the developed tool ranged from 69-89% for advertisements and establishments. Results suggest that the developed tool is highly reliable and effective for documenting the outdoor FB environment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Visual-Haptic Integration: Cue Weights are Varied Appropriately, to Account for Changes in Haptic Reliability Introduced by Using a Tool

    Directory of Open Access Journals (Sweden)

    Chie Takahashi

    2011-10-01

    Full Text Available Tools such as pliers systematically change the relationship between an object's size and the hand opening required to grasp it. Previous work suggests the brain takes this into account, integrating visual and haptic size information that refers to the same object, independent of the similarity of the ‘raw’ visual and haptic signals (Takahashi et al., VSS 2009. Variations in tool geometry also affect the reliability (precision of haptic size estimates, however, because they alter the change in hand opening caused by a given change in object size. Here, we examine whether the brain appropriately adjusts the weights given to visual and haptic size signals when tool geometry changes. We first estimated each cue's reliability by measuring size-discrimination thresholds in vision-alone and haptics-alone conditions. We varied haptic reliability using tools with different object-size:hand-opening ratios (1:1, 0.7:1, and 1.4:1. We then measured the weights given to vision and haptics with each tool, using a cue-conflict paradigm. The weight given to haptics varied with tool type in a manner that was well predicted by the single-cue reliabilities (MLE model; Ernst and Banks, 2002. This suggests that the process of visual-haptic integration appropriately accounts for variations in haptic reliability introduced by different tool geometries.

  14. A Valid and Reliable Tool to Assess Nursing Students` Clinical Performance

    OpenAIRE

    Mehrnoosh Pazargadi; Tahereh Ashktorab; Sharareh Khosravi; Hamid Alavi majd

    2013-01-01

    Background: The necessity of a valid and reliable assessment tool is one of the most repeated issues in nursing students` clinical evaluation. But it is believed that present tools are not mostly valid and can not assess students` performance properly.Objectives: This study was conducted to design a valid and reliable assessment tool for evaluating nursing students` performance in clinical education.Methods: In this methodological study considering nursing students` performance definition; th...

  15. A Reliable Method to Measure Lip Height Using Photogrammetry in Unilateral Cleft Lip Patients.

    Science.gov (United States)

    van der Zeeuw, Frederique; Murabit, Amera; Volcano, Johnny; Torensma, Bart; Patel, Brijesh; Hay, Norman; Thorburn, Guy; Morris, Paul; Sommerlad, Brian; Gnarra, Maria; van der Horst, Chantal; Kangesu, Loshan

    2015-09-01

    There is still no reliable tool to determine the outcome of the repaired unilateral cleft lip (UCL). The aim of this study was therefore to develop an accurate, reliable tool to measure vertical lip height from photographs. The authors measured the vertical height of the cutaneous and vermilion parts of the lip in 72 anterior-posterior view photographs of 17 patients with repairs to a UCL. Points on the lip's white roll and vermillion were marked on both the cleft and the noncleft sides on each image. Two new concepts were tested. First, photographs were standardized using the horizontal (medial to lateral) eye fissure width (EFW) for calibration. Second, the authors tested the interpupillary line (IPL) and the alar base line (ABL) for their reliability as horizontal lines of reference. Measurements were taken by 2 independent researchers, at 2 different time points each. Overall 2304 data points were obtained and analyzed. Results showed that the method was very effective in measuring the height of the lip on the cleft side with the noncleft side. When using the IPL, inter- and intra-rater reliability was 0.99 to 1.0, with the ABL it varied from 0.91 to 0.99 with one exception at 0.84. The IPL was easier to define because in some subjects the overhanging nasal tip obscured the alar base and gave more consistent measurements possibly because the reconstructed alar base was sometimes indistinct. However, measurements from the IPL can only give the percentage difference between the left and right sides of the lip, whereas those from the ABL can also give exact measurements. Patient examples were given that show how the measurements correlate with clinical assessment. The authors propose this method of photogrammetry with the innovative use of the IPL as a reliable horizontal plane and use of the EFW for calibration as a useful and reliable tool to assess the outcome of UCL repair.

  16. OSS reliability measurement and assessment

    CERN Document Server

    Yamada, Shigeru

    2016-01-01

    This book analyses quantitative open source software (OSS) reliability assessment and its applications, focusing on three major topic areas: the Fundamentals of OSS Quality/Reliability Measurement and Assessment; the Practical Applications of OSS Reliability Modelling; and Recent Developments in OSS Reliability Modelling. Offering an ideal reference guide for graduate students and researchers in reliability for open source software (OSS) and modelling, the book introduces several methods of reliability assessment for OSS including component-oriented reliability analysis based on analytic hierarchy process (AHP), analytic network process (ANP), and non-homogeneous Poisson process (NHPP) models, the stochastic differential equation models and hazard rate models. These measurement and management technologies are essential to producing and maintaining quality/reliable systems using OSS.

  17. RADYBAN: A tool for reliability analysis of dynamic fault trees through conversion into dynamic Bayesian networks

    International Nuclear Information System (INIS)

    Montani, S.; Portinale, L.; Bobbio, A.; Codetta-Raiteri, D.

    2008-01-01

    In this paper, we present RADYBAN (Reliability Analysis with DYnamic BAyesian Networks), a software tool which allows to analyze a dynamic fault tree relying on its conversion into a dynamic Bayesian network. The tool implements a modular algorithm for automatically translating a dynamic fault tree into the corresponding dynamic Bayesian network and exploits classical algorithms for the inference on dynamic Bayesian networks, in order to compute reliability measures. After having described the basic features of the tool, we show how it operates on a real world example and we compare the unreliability results it generates with those returned by other methodologies, in order to verify the correctness and the consistency of the results obtained

  18. Assessing communication skills in dietetic consultations: the development of the reliable and valid DIET-COMMS tool.

    Science.gov (United States)

    Whitehead, K A; Langley-Evans, S C; Tischler, V A; Swift, J A

    2014-04-01

    There is an increasing emphasis on the development of communication skills for dietitians but few evidence-based assessment tools available. The present study aimed to develop a dietetic-specific, short, reliable and valid assessment tool for measuring communication skills in patient consultations: DIET-COMMS. A literature review and feedback from 15 qualified dietitians were used to establish face and content validity during the development of DIET-COMMS. In total, 113 dietetic students and qualified dietitians were video-recorded undertaking mock consultations, assessed using DIET-COMMS by the lead author, and used to establish intra-rater reliability, as well as construct and predictive validity. Twenty recorded consultations were reassessed by nine qualified dietitians to assess inter-rater reliability: eight of these assessors were interviewed to determine user evaluation. Significant improvements in DIET-COMMS scores were achieved as students and qualified staff progressed through their training and gained experience, demonstrating construct validity, and also by qualified staff attending a training course, indicating predictive validity (P skills in practice was questioned. DIET-COMMS is a short, user-friendly, reliable and valid tool for measuring communication skills in patient consultations with both pre- and post-registration dietitians. Additional work is required to develop a training package for assessors and to identify how DIET-COMMS assessment can acceptably be incorporated into practice. © 2013 The British Dietetic Association Ltd.

  19. The risk of bias in systematic reviews tool showed fair reliability and good construct validity.

    Science.gov (United States)

    Bühn, Stefanie; Mathes, Tim; Prengel, Peggy; Wegewitz, Uta; Ostermann, Thomas; Robens, Sibylle; Pieper, Dawid

    2017-11-01

    There is a movement from generic quality checklists toward a more domain-based approach in critical appraisal tools. This study aimed to report on a first experience with the newly developed risk of bias in systematic reviews (ROBIS) tool and compare it with A Measurement Tool to Assess Systematic Reviews (AMSTAR), that is, the most common used tool to assess methodological quality of systematic reviews while assessing validity, reliability, and applicability. Validation study with four reviewers based on 16 systematic reviews in the field of occupational health. Interrater reliability (IRR) of all four raters was highest for domain 2 (Fleiss' kappa κ = 0.56) and lowest for domain 4 (κ = 0.04). For ROBIS, median IRR was κ = 0.52 (range 0.13-0.88) for the experienced pair of raters compared to κ = 0.32 (range 0.12-0.76) for the less experienced pair of raters. The percentage of "yes" scores of each review of ROBIS ratings was strongly correlated with the AMSTAR ratings (r s  = 0.76; P = 0.01). ROBIS has fair reliability and good construct validity to assess the risk of bias in systematic reviews. More validation studies are needed to investigate reliability and applicability, in particular. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Endoscopy nurse-administered propofol sedation performance. Development of an assessment tool and a reliability testing model

    DEFF Research Database (Denmark)

    Jensen, Jeppe Thue; Konge, Lars; Møller, Ann

    2014-01-01

    of training and for future certification. The aim of this study was to develop an assessment tool for measuring competency in propofol sedation and to explore the reliability and validity of the tool. MATERIAL AND METHODS: The nurse-administered propofol assessment tool (NAPSAT) was developed in a Delphi...... and good construct validity. This makes NAPSAT fit for formative assessment and proficiency feedback; however, high stakes and summative assessment cannot be advised....

  1. Inter-rater reliability of shoulder measurements in middle-aged women.

    Science.gov (United States)

    De Groef, A; Van Kampen, M; Vervloesem, N; Clabau, E; Christiaens, M-R; Neven, P; Geraerts, I; Struyf, F; Devoogdt, N

    2017-06-01

    To investigate inter-rater reliability of a set of shoulder measurements including inclinometry [shoulder range of motion (ROM)], acromion-table distance and pectoralis minor muscle length (static scapular positioning), upward rotation with two inclinometers (scapular kinematics) and pain pressure thresholds (muscle tenderness) in middle-aged women. Observational study. Thirty symptom-free middle-aged women (first cohort) were measured by two raters. All measurements with an intraclass correlation coefficient (ICC) below 0.75 were retested after an additional training period in a second cohort of 30 symptom-free middle-aged women. Inter-rater reliability of all variables was measured with the ICC (95% confidence interval) and standard error of measurement (SEM). Acromion-table distance (ICC=0.91, SEM 0.22 to 0.28% of body length), pectoralis minor muscle length (ICC=0.91, SEM 0.16% of body length), pain pressure thresholds (ICC=0.78 to 0.85, SEM 0.39 to 0.70kg) and abduction ROM (ICC=0.77, SEM 5°) showed good to excellent inter-rater reliability in the first cohort. After an additional training period, forward flexion ROM showed good inter-rater reliability (ICC=0.83, SEM 5°), scapular upward rotation in resting position showed moderate reliability (ICC=0.52, SEM 2°), and other scaption angles showed weak reliability (ICC=0.26 to 0.43, SEM 3 to 8°). In a battery of clinical tools to evaluate factors contributing to shoulder pain, static scapular positioning and pressure pain thresholds were found to have good to excellent inter-rater reliability in middle-aged women. Additional training is recommended for measurements with a gravity inclinometer. Copyright © 2016 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  2. The Myotonometer: Not a Valid Measurement Tool for Active Hamstring Musculotendinous Stiffness.

    Science.gov (United States)

    Pamukoff, Derek N; Bell, Sarah E; Ryan, Eric D; Blackburn, J Troy

    2016-05-01

    Hamstring musculotendinous stiffness (MTS) is associated with lower-extremity injury risk (ie, hamstring strain, anterior cruciate ligament injury) and is commonly assessed using the damped oscillatory technique. However, despite a preponderance of studies that measure MTS reliably in laboratory settings, there are no valid clinical measurement tools. A valid clinical measurement technique is needed to assess MTS and permit identification of individuals at heightened risk of injury and track rehabilitation progress. To determine the validity and reliability of the Myotonometer for measuring active hamstring MTS. Descriptive laboratory study. Laboratory. 33 healthy participants (15 men, age 21.33 ± 2.94 y, height 172.03 ± 16.36 cm, mass 74.21 ± 16.36 kg). Hamstring MTS was assessed using the damped oscillatory technique and the Myotonometer. Intraclass correlations were used to determine the intrasession, intersession, and interrater reliability of the Myotonometer. Criterion validity was assessed via Pearson product-moment correlation between MTS measures obtained from the Myotonometer and from the damped oscillatory technique. The Myotonometer demonstrated good intrasession (ICC3,1 = .807) and interrater reliability (ICC2,k = .830) and moderate intersession reliability (ICC2,k = .693). However, it did not provide a valid measurement of MTS compared with the damped oscillatory technique (r = .346, P = .061). The Myotonometer does not provide a valid measure of active hamstring MTS. Although the Myotonometer does not measure active MTS, it possesses good reliability and portability and could be used clinically to measure tissue compliance, muscle tone, or spasticity associated with multiple musculoskeletal disorders. Future research should focus on portable and clinically applicable tools to measure active hamstring MTS in efforts to prevent and monitor injuries.

  3. Traceability of On-Machine Tool Measurement: A Review

    Science.gov (United States)

    Gomez-Acedo, Eneko; Kortaberria, Gorka; Olarra, Aitor

    2017-01-01

    Nowadays, errors during the manufacturing process of high value components are not acceptable in driving industries such as energy and transportation. Sectors such as aerospace, automotive, shipbuilding, nuclear power, large science facilities or wind power need complex and accurate components that demand close measurements and fast feedback into their manufacturing processes. New measuring technologies are already available in machine tools, including integrated touch probes and fast interface capabilities. They provide the possibility to measure the workpiece in-machine during or after its manufacture, maintaining the original setup of the workpiece and avoiding the manufacturing process from being interrupted to transport the workpiece to a measuring position. However, the traceability of the measurement process on a machine tool is not ensured yet and measurement data is still not fully reliable enough for process control or product validation. The scientific objective is to determine the uncertainty on a machine tool measurement and, therefore, convert it into a machine integrated traceable measuring process. For that purpose, an error budget should consider error sources such as the machine tools, components under measurement and the interactions between both of them. This paper reviews all those uncertainty sources, being mainly focused on those related to the machine tool, either on the process of geometric error assessment of the machine or on the technology employed to probe the measurand. PMID:28696358

  4. Traceability of On-Machine Tool Measurement: A Review.

    Science.gov (United States)

    Mutilba, Unai; Gomez-Acedo, Eneko; Kortaberria, Gorka; Olarra, Aitor; Yagüe-Fabra, Jose A

    2017-07-11

    Nowadays, errors during the manufacturing process of high value components are not acceptable in driving industries such as energy and transportation. Sectors such as aerospace, automotive, shipbuilding, nuclear power, large science facilities or wind power need complex and accurate components that demand close measurements and fast feedback into their manufacturing processes. New measuring technologies are already available in machine tools, including integrated touch probes and fast interface capabilities. They provide the possibility to measure the workpiece in-machine during or after its manufacture, maintaining the original setup of the workpiece and avoiding the manufacturing process from being interrupted to transport the workpiece to a measuring position. However, the traceability of the measurement process on a machine tool is not ensured yet and measurement data is still not fully reliable enough for process control or product validation. The scientific objective is to determine the uncertainty on a machine tool measurement and, therefore, convert it into a machine integrated traceable measuring process. For that purpose, an error budget should consider error sources such as the machine tools, components under measurement and the interactions between both of them. This paper reviews all those uncertainty sources, being mainly focused on those related to the machine tool, either on the process of geometric error assessment of the machine or on the technology employed to probe the measurand.

  5. A Study on the Reliability of Sasang Constitutional Body Trunk Measurement

    Directory of Open Access Journals (Sweden)

    Eunsu Jang

    2012-01-01

    Full Text Available Objective. Body trunk measurement for human plays an important diagnostic role not only in conventional medicine but also in Sasang constitutional medicine (SCM. The Sasang constitutional body trunk measurement (SCBTM consists of the 5-widths and the 8-circumferences which are standard locations currently employed in the SCM society. This study suggests to what extent a comprehensive training can improve the reliability of the SCBTM. Methods. We recruited 10 male subjects and 5 male observers with no experience of anthropometric measurement. We conducted measurements twice before and after a comprehensive training. Relative technical error of measurement (%TEMs was produced to assess intra and inter observer reliabilities. Results. Post-training intra-observer %TEMs of the SCBTM were 0.27% to 1.85% reduced from 0.27% to 6.26% in pre-training, respectively. Post-training inter-observer %TEMs of those were 0.56% to 1.66% reduced from 1.00% to 9.60% in pre-training, respectively. Post-training % total TEMs which represent the whole reliability were 0.68% to 2.18% reduced from maximum value of 10.18%. Conclusion. A comprehensive training makes the SCBTM more reliable, hence giving a sufficiently confident diagnostic tool. It is strongly recommended to give a comprehensive training in advance to take the SCBTM.

  6. A study on the reliability of sasang constitutional body trunk measurement.

    Science.gov (United States)

    Jang, Eunsu; Kim, Jong Yeol; Lee, Haejung; Kim, Honggie; Baek, Younghwa; Lee, Siwoo

    2012-01-01

    Objective. Body trunk measurement for human plays an important diagnostic role not only in conventional medicine but also in Sasang constitutional medicine (SCM). The Sasang constitutional body trunk measurement (SCBTM) consists of the 5-widths and the 8-circumferences which are standard locations currently employed in the SCM society. This study suggests to what extent a comprehensive training can improve the reliability of the SCBTM. Methods. We recruited 10 male subjects and 5 male observers with no experience of anthropometric measurement. We conducted measurements twice before and after a comprehensive training. Relative technical error of measurement (%TEMs) was produced to assess intra and inter observer reliabilities. Results. Post-training intra-observer %TEMs of the SCBTM were 0.27% to 1.85% reduced from 0.27% to 6.26% in pre-training, respectively. Post-training inter-observer %TEMs of those were 0.56% to 1.66% reduced from 1.00% to 9.60% in pre-training, respectively. Post-training % total TEMs which represent the whole reliability were 0.68% to 2.18% reduced from maximum value of 10.18%. Conclusion. A comprehensive training makes the SCBTM more reliable, hence giving a sufficiently confident diagnostic tool. It is strongly recommended to give a comprehensive training in advance to take the SCBTM.

  7. Assessing Households Preparedness for Earthquakes: An Exploratory Study in the Development of a Valid and Reliable Persian-version Tool.

    Science.gov (United States)

    Ardalan, Ali; Sohrabizadeh, Sanaz

    2016-02-25

    Iran is placed among countries suffering from the highest number of earthquake casualties. Household preparedness, as one component of risk reduction efforts, is often supported in quake-prone areas. In Iran, lack of a valid and reliable household preparedness tool was reported by previous disaster studies. This study is aimed to fill this gap by developing a valid and reliable tool for assessing household preparedness in the event of an earthquake.  This survey was conducted through three phases including literature review and focus group discussions with the participation of eight key informants, validity measurements and reliability measurements. Field investigation was completed with the participation of 450 households within three provinces of Iran. Content validity, construct validity, the use of factor analysis; internal consistency using Cronbach's alpha coefficient, and test-retest reliability were carried out to develop the tool.  Based on the CVIs, ranging from 0.80 to 0.100, and exploratory factor analysis with factor loading of more than 0.5, all items were valid. The amount of Cronbach's alpha (0.7) and test-retest examination by Spearman correlations indicated that the scale was also reliable. The final instrument consisted of six categories and 18 questions including actions at the time of earthquakes, nonstructural safety, structural safety, hazard map, communications, drill, and safety skills.  Using a Persian-version tool that is adjusted to the socio-cultural determinants and native language may result in more trustful information on earthquake preparedness. It is suggested that disaster managers and researchers apply this tool in their future household preparedness projects. Further research is needed to make effective policies and plans for transforming preparedness knowledge into behavior.

  8. Reliability and Validity Study of a Tool to Measure Cancer Stigma: Patient Version.

    Science.gov (United States)

    Yılmaz, Medine; Dişsiz, Gülçin; Demir, Filiz; Irız, Sibel; Alacacioglu, Ahmet

    2017-01-01

    The aim of this methodological study is to establish the validity and reliability of the Turkish version of "A Questionnaire for Measuring Attitudes toward Cancer (Cancer Stigma) - Patient version." The sample comprised oncology patients who had active cancer treatment. The construct validity was assessed using the confirmatory and exploratory factor analysis. The mean age of the participants was 54.9±12.3 years. In the confirmatory factor analysis, fit values were determined as comparative fit index = 0.93, goodness of fit index = 0.91, normed-fit index=0.91, and root mean square error of approximation RMSEA = 0.09 ( P Kaiser-Meyer-Olkin = 0.88, χ 2 = 1084.41, Df = 66, and Barletta's test P <0.000). The first factor was "impossibility of recovery and experience of social discrimination" and the second factor was "stereotypes of cancer patients." The two-factor structure accounted for 56.74% of the variance. The Cronbach's alpha value was determined as 0.88 for the two-factor scale. "A questionnaire for measuring attitudes toward cancer (cancer stigma) - Patient version" is a reliable and valid questionnaire to assess stigmatization of cancer in cancer patients.

  9. Development of a quality-assessment tool for experimental bruxism studies: reliability and validity.

    Science.gov (United States)

    Dawson, Andreas; Raphael, Karen G; Glaros, Alan; Axelsson, Susanna; Arima, Taro; Ernberg, Malin; Farella, Mauro; Lobbezoo, Frank; Manfredini, Daniele; Michelotti, Ambra; Svensson, Peter; List, Thomas

    2013-01-01

    To combine empirical evidence and expert opinion in a formal consensus method in order to develop a quality-assessment tool for experimental bruxism studies in systematic reviews. Tool development comprised five steps: (1) preliminary decisions, (2) item generation, (3) face-validity assessment, (4) reliability and discriminitive validity assessment, and (5) instrument refinement. The kappa value and phi-coefficient were calculated to assess inter-observer reliability and discriminative ability, respectively. Following preliminary decisions and a literature review, a list of 52 items to be considered for inclusion in the tool was compiled. Eleven experts were invited to join a Delphi panel and 10 accepted. Four Delphi rounds reduced the preliminary tool-Quality-Assessment Tool for Experimental Bruxism Studies (Qu-ATEBS)- to 8 items: study aim, study sample, control condition or group, study design, experimental bruxism task, statistics, interpretation of results, and conflict of interest statement. Consensus among the Delphi panelists yielded good face validity. Inter-observer reliability was acceptable (k = 0.77). Discriminative validity was excellent (phi coefficient 1.0; P reviews of experimental bruxism studies, exhibits face validity, excellent discriminative validity, and acceptable inter-observer reliability. Development of quality assessment tools for many other topics in the orofacial pain literature is needed and may follow the described procedure.

  10. Perceptual attraction in tool use: evidence for a reliability-based weighting mechanism.

    Science.gov (United States)

    Debats, Nienke B; Ernst, Marc O; Heuer, Herbert

    2017-04-01

    Humans are well able to operate tools whereby their hand movement is linked, via a kinematic transformation, to a spatially distant object moving in a separate plane of motion. An everyday example is controlling a cursor on a computer monitor. Despite these separate reference frames, the perceived positions of the hand and the object were found to be biased toward each other. We propose that this perceptual attraction is based on the principles by which the brain integrates redundant sensory information of single objects or events, known as optimal multisensory integration. That is, 1 ) sensory information about the hand and the tool are weighted according to their relative reliability (i.e., inverse variances), and 2 ) the unisensory reliabilities sum up in the integrated estimate. We assessed whether perceptual attraction is consistent with optimal multisensory integration model predictions. We used a cursor-control tool-use task in which we manipulated the relative reliability of the unisensory hand and cursor position estimates. The perceptual biases shifted according to these relative reliabilities, with an additional bias due to contextual factors that were present in experiment 1 but not in experiment 2 The biased position judgments' variances were, however, systematically larger than the predicted optimal variances. Our findings suggest that the perceptual attraction in tool use results from a reliability-based weighting mechanism similar to optimal multisensory integration, but that certain boundary conditions for optimality might not be satisfied. NEW & NOTEWORTHY Kinematic tool use is associated with a perceptual attraction between the spatially separated hand and the effective part of the tool. We provide a formal account for this phenomenon, thereby showing that the process behind it is similar to optimal integration of sensory information relating to single objects. Copyright © 2017 the American Physiological Society.

  11. Designing a clinical audit tool to measure processes of pregnancy care

    Directory of Open Access Journals (Sweden)

    Wallace EM

    2011-12-01

    Full Text Available Suzanne V Sinni1, Wendy M Cross2, Euan M Wallace1,31Department of Obstetrics and Gynaecology, Monash University and Southern Health, Monash Medical Centre, Clayton, Victoria, 2School of Nursing and Midwifery, Monash University, Clayton, Victoria, 3The Ritchie Centre, Monash Institute of Medical Research, Monash University, Clayton, Victoria, AustraliaAbstract: This paper reports the development of a clinical audit tool as part of a larger project to evaluate a new maternity service, underpinned by a patient safety framework.Aim: The aim of this work is to describe the development of a clinical audit tool that measures the process of pregnancy care, and its application.Background: There are many reports about outcomes of healthcare provision, however there are limited studies examining the process of care. There is also limited evidence linking clinical audit with improvements in care delivery. Pregnancy care was chosen because there are well defined and agreed clinical standards against which to measure the delivery of pregnancy care. A clinical audit using these standards addresses both gaps in the literature.Methods: Standard methodological processes were used to develop the audit tool. Literature informed the processes. Data were collected in 2009–2010 using the tool described in the paper. Reliability testing was completed in September 2011.Results: An audit tool to measure pregnancy care was developed and applied to 354 health records to enable analysis of adherence to organizational expectations of care. Reliability testing of the tool achieved an overall kappa of 0.896.Conclusion: Developing an audit tool based on processes described in the literature is labor intensive and resource dependent, however it results in a robust, reliable, valid tool that can be used in diverse maternity services. Stakeholder participation from the outset ensures ongoing engagement for the duration of a clinically based project spanning several years

  12. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 1: HARP introduction and user's guide

    Science.gov (United States)

    Bavuso, Salvatore J.; Rothmann, Elizabeth; Dugan, Joanne Bechta; Trivedi, Kishor S.; Mittal, Nitin; Boyd, Mark A.; Geist, Robert M.; Smotherman, Mark D.

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed to be compatible with most computing platforms and operating systems, and some programs have been beta tested, within the aerospace community for over 8 years. Volume 1 provides an introduction to the HARP program. Comprehensive information on HARP mathematical models can be found in the references.

  13. Facial Angiofibroma Severity Index (FASI): reliability assessment of a new tool developed to measure severity and responsiveness to therapy in tuberous sclerosis-associated facial angiofibroma.

    Science.gov (United States)

    Salido-Vallejo, R; Ruano, J; Garnacho-Saucedo, G; Godoy-Gijón, E; Llorca, D; Gómez-Fernández, C; Moreno-Giménez, J C

    2014-12-01

    Tuberous sclerosis complex (TSC) is an autosomal dominant neurocutaneous disorder characterized by the development of multisystem hamartomatous tumours. Topical sirolimus has recently been suggested as a potential treatment for TSC-associated facial angiofibroma (FA). To validate a reproducible scale created for the assessment of clinical severity and treatment response in these patients. We developed a new tool, the Facial Angiofibroma Severity Index (FASI) to evaluate the grade of erythema and the size and extent of FAs. In total, 30 different photographs of patients with TSC were shown to 56 dermatologists at each evaluation. Three evaluations using the same photographs but in a different random order were performed 1 week apart. Test and retest reliability and interobserver reproducibility were determined. There was good agreement between the investigators. Inter-rater reliability showed strong correlations (> 0.98; range 0.97-0.99) with inter-rater correlation coefficients (ICCs) for the FASI. The global estimated kappa coefficient for the degree of intra-rater agreement (test-retest) was 0.94 (range 0.91-0.97). The FASI is a valid and reliable tool for measuring the clinical severity of TSC-associated FAs, which can be applied in clinical practice to evaluate the response to treatment in these patients. © 2014 British Association of Dermatologists.

  14. Reliability and responsiveness of a goniometric device for measuring the range of motion in the dart-throwing motion plane.

    Science.gov (United States)

    Kasubuchi, Kenji; Dohi, Yoshihiro; Fujita, Hiroyuki; Fukumoto, Takahiko

    2018-02-26

    Dart-throwing motion (DTM) is an important component of wrist function and, consequently, has the potential to become an evaluation tool in rehabilitation. However, no measurement method is currently available to reliably measure range of motion (ROM) of the wrist in the DTM plane. To determine the reliability and responsiveness of a goniometric device to measure wrist ROM in the DTM plane. ROM of the wrist in the DTM plane was measured in 70 healthy participants. The intra-class correlation coefficient (ICC) was used to evaluate the relative reliability of measurement, and a Bland-Altman analysis conducted to establish its absolute reliability, including the 95% limits of agreement (95% LOA). The standard error of the measurement (SEM) and minimal detectable change at the 95% confidence level (MDC 95 ) were calculated as measures of responsiveness. The intra-rater ICC was 0.87, and an inter-rater ICC of 0.71. There was no evidence of a fixed or proportional bias. For intra- and inter-rater reliability, 95% LOA ranged from -13.83 to 11.12 and from -17.75 to 16.19, respectively. The SEM and MDC 95 were 4.5° and 12.4°, respectively, for intra-rater reliability, and 6.0° and 16.6°, respectively, for inter-rater reliability. The ROM of the wrist in the DTM plane was measured with fair-to-good reliability and responsiveness and, therefore, has the potential to become an evaluation tool for rehabilitation.

  15. Testing the reliability of the Fall Risk Screening Tool in an elderly ambulatory population.

    Science.gov (United States)

    Fielding, Susan J; McKay, Michael; Hyrkas, Kristiina

    2013-11-01

    To identify and test the reliability of a fall risk screening tool in an ambulatory outpatient clinic. The Fall Risk Screening Tool (Albert Lea Medical Center, MN, USA) was scripted for an interview format. Two interviewers separately screened a convenience sample of 111 patients (age ≥ 65 years) in an ambulatory outpatient clinic in a northeastern US city. The interviewers' scoring of fall risk categories was similar. There was good internal consistency (Cronbach's α = 0.834-0.889) and inter-rater reliability [intra-class correlation coefficients (ICC) = 0.824-0.881] for total, Risk Factor and Client's Health Status subscales. The Physical Environment scores indicated acceptable internal consistency (Cronbach's α = 0.742) and adequate reliability (ICC = 0.688). Two Physical Environment items (furniture and medical equipment condition) had low reliabilities [Kappa (K) = 0.323, P = 0.08; K = -0.078, P = 0.648), respectively. The scripted Fall Risk Screening Tool demonstrated good reliability in this sample. Rewording two Physical Environment items will be considered. A reliable instrument such as the scripted Fall Risk Screening Tool provides a standardised assessment for identifying high fall risk patients. This tool is especially useful because it assesses personal, behavioural and environmental factors specific to community-dwelling patients; the interview format also facilitates patient-provider interaction. © 2013 John Wiley & Sons Ltd.

  16. The cognitive environment simulation as a tool for modeling human performance and reliability

    International Nuclear Information System (INIS)

    Woods, D.D.; Pople, H. Jr.; Roth, E.M.

    1990-01-01

    The US Nuclear Regulatory Commission is sponsoring a research program to develop improved methods to model the cognitive behavior of nuclear power plant (NPP) personnel. Under this program, a tool for simulating how people form intentions to act in NPP emergency situations was developed using artificial intelligence (AI) techniques. This tool is called Cognitive Environment Simulation (CES). The Cognitive Reliability Assessment Technique (or CREATE) was also developed to specify how CBS can be used to enhance the measurement of the human contribution to risk in probabilistic risk assessment (PRA) studies. The next step in the research program was to evaluate the modeling tool and the method for using the tool for Human Reliability Analysis (HRA) in PRAs. Three evaluation activities were conducted. First, a panel of highly distinguished experts in cognitive modeling, AI, PRA and HRA provided a technical review of the simulation development work. Second, based on panel recommendations, CES was exercised on a family of steam generator tube rupture incidents where empirical data on operator performance already existed. Third, a workshop with HRA practitioners was held to analyze a worked example of the CREATE method to evaluate the role of CES/CREATE in HRA. The results of all three evaluations indicate that CES/CREATE represents a promising approach to modeling operator intention formation during emergency operations

  17. Reliability and validity study of a tool to measure cancer stigma: Patient version

    Directory of Open Access Journals (Sweden)

    Medine Yilmaz

    2017-01-01

    Full Text Available Objective: The aim of this methodological study is to establish the validity and reliability of the Turkish version of “A Questionnaire for Measuring Attitudes toward Cancer (Cancer Stigma - Patient version.” Methods: The sample comprised oncology patients who had active cancer treatment. The construct validity was assessed using the confirmatory and exploratory factor analysis. Results: The mean age of the participants was 54.9±12.3 years. In the confirmatory factor analysis, fit values were determined as comparative fit index = 0.93, goodness of fit index = 0.91, normed-fit index=0.91, and root mean square error of approximation RMSEA = 0.09 (P<0.05 (Kaiser–Meyer–Olkin = 0.88, χ2 = 1084.41, Df = 66, and Barletta's test P<0.000. The first factor was “impossibility of recovery and experience of social discrimination” and the second factor was “stereotypes of cancer patients.” The two-factor structure accounted for 56.74% of the variance. The Cronbach's alpha value was determined as 0.88 for the two-factor scale. Conclusions: “A questionnaire for measuring attitudes toward cancer (cancer stigma - Patient version” is a reliable and valid questionnaire to assess stigmatization of cancer in cancer patients.

  18. Allied health clinicians using translational research in action to develop a reliable stroke audit tool.

    Science.gov (United States)

    Abery, Philip; Kuys, Suzanne; Lynch, Mary; Low Choy, Nancy

    2018-05-23

    To design and establish reliability of a local stroke audit tool by engaging allied health clinicians within a privately funded hospital. Design: Two-stage study involving a modified Delphi process to inform stroke audit tool development and inter-tester reliability. Allied health clinicians. A modified Delphi process to select stroke guideline recommendations for inclusion in the audit tool. Reliability study: 1 allied health representative from each discipline audited 10 clinical records with sequential admissions to acute and rehabilitation services. Recommendations were admitted to the audit tool when 70% agreement was reached, with 50% set as the reserve agreement. Inter-tester reliability was determined using intra-class correlation coefficients (ICCs) across 10 clinical records. Twenty-two participants (92% female, 50% physiotherapists, 17% occupational therapists) completed the modified Delphi process. Across 6 voting rounds, 8 recommendations reached 70% agreement and 2 reached 50% agreement. Two recommendations (nutrition/hydration; goal setting) were added to ensure representation for all disciplines. Substantial consistency across raters was established for the audit tool applied in acute stroke (ICC .71; range .48 to .90) and rehabilitation (ICC.78; range .60 to .93) services. Allied health clinicians within a privately funded hospital generally agreed in an audit process to develop a reliable stroke audit tool. Allied health clinicians agreed on stroke guideline recommendations to inform a stroke audit tool. The stroke audit tool demonstrated substantial consistency supporting future use for service development. This process, which engages local clinicians, could be adopted by other facilities to design reliable audit tools to identify local service gaps to inform changes to clinical practice. © 2018 John Wiley & Sons, Ltd.

  19. The reliability of commonly used electrophysiology measures.

    Science.gov (United States)

    Brown, K E; Lohse, K R; Mayer, I M S; Strigaro, G; Desikan, M; Casula, E P; Meunier, S; Popa, T; Lamy, J-C; Odish, O; Leavitt, B R; Durr, A; Roos, R A C; Tabrizi, S J; Rothwell, J C; Boyd, L A; Orth, M

    Electrophysiological measures can help understand brain function both in healthy individuals and in the context of a disease. Given the amount of information that can be extracted from these measures and their frequent use, it is essential to know more about their inherent reliability. To understand the reliability of electrophysiology measures in healthy individuals. We hypothesized that measures of threshold and latency would be the most reliable and least susceptible to methodological differences between study sites. Somatosensory evoked potentials from 112 control participants; long-latency reflexes, transcranial magnetic stimulation with resting and active motor thresholds, motor evoked potential latencies, input/output curves, and short-latency sensory afferent inhibition and facilitation from 84 controls were collected at 3 visits over 24 months at 4 Track-On HD study sites. Reliability was assessed using intra-class correlation coefficients for absolute agreement, and the effects of reliability on statistical power are demonstrated for different sample sizes and study designs. Measures quantifying latencies, thresholds, and evoked responses at high stimulator intensities had the highest reliability, and required the smallest sample sizes to adequately power a study. Very few between-site differences were detected. Reliability and susceptibility to between-site differences should be evaluated for electrophysiological measures before including them in study designs. Levels of reliability vary substantially across electrophysiological measures, though there are few between-site differences. To address this, reliability should be used in conjunction with theoretical calculations to inform sample size and ensure studies are adequately powered to detect true change in measures of interest. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Reliability of Eustachian tube function measurements in a hypobaric and hyperbaric pressure chamber.

    Science.gov (United States)

    Meyer, M F; Jansen, S; Mordkovich, O; Hüttenbrink, K-B; Beutner, D

    2017-12-01

    Measurement of the Eustachian tube (ET) function is a challenge. The demand for a precise and meaningful diagnostic tool increases-especially because more and more operative therapies are being offered without objective evidence. The measurement of the ET function by continuous impedance recording in a pressure chamber is an established method, although the reliability of the measurements is still unclear. Twenty-five participants (50 ears) were exposed to phases of compression and decompression in a hypo- and hyperbaric pressure chamber. The ET function reflecting parameters-ET opening pressure (ETOP), ET opening duration (ETOD) and ET opening frequency (ETOF)-were determined under exactly the same preconditions three times in a row. The intraclass correlation coefficient (ICC) and Bland and Altman plot were used to assess test-retest reliability. ICCs revealed a high correlation for ETOP and ETOF in phases of decompression (passive equalisation) as well as ETOD and ETOP in phases of compression (active induced equalisation). Very high correlation could be shown for ETOD in decompression and ETOF in compression phases. The Bland and Altman graphs could show that measurements provide results within a 95 % confidence interval in compression and decompression phases. We conclude that measurements in a pressure chamber are a very valuable tool in terms of estimating the ET opening and closing function. Measurements show some variance comparing participants, but provide reliable results within a 95 % confidence interval in retest. This study is the basis for enabling efficacy measurements of ET treatment modalities. © 2017 John Wiley & Sons Ltd.

  1. Cross-cultural adaptation, reliability, and validity of the Persian version of the Cumberland Ankle Instability Tool.

    Science.gov (United States)

    Hadadi, Mohammad; Ebrahimi Takamjani, Ismail; Ebrahim Mosavi, Mohammad; Aminian, Gholamreza; Fardipour, Shima; Abbasi, Faeze

    2017-08-01

    The purpose of the present study was to translate and to cross-culturally adapt the Cumberland Ankle Instability Tool (CAIT) into Persian language and to evaluate its psychometric properties. The International Quality of Life Assessment process was pursued to translate CAIT into Persian. Two groups of Persian-speaking individuals, 105 participants with a history of ankle sprain and 30 participants with no history of ankle sprain, were asked to fill out Persian version of CAIT (CAIT-P), Foot and Ankle Ability Measure (FAAM), and Visual Analog Scale (VAS). Data obtained from the first administration of CAIT were used to evaluate floor and ceiling effects, internal consistency, dimensionality, and criterion validity. To determine the test-retest reliability, 45 individuals re-filled CAIT 5-7 days after the first session. Cronbach's alpha was over the cutoff point of 0.70 for both ankles and in both groups. The intra-class correlation coefficient was high for right (0.95) and left (0.91) ankles. There was a strong correlation between each item and the total score of the CAIT-P. Although the CAIT-P had strong correlation with VAS, its correlation with both subscales of FAAM was moderate. The CAIT-P has good validity and reliability and it can be used by clinicians and researchers for identification and investigation of functional ankle instability. Implications for Rehabilitation Chronic ankle instability is one of the most common consequences of acute ankle sprain. Cumberland Ankle Instability Tool is an acceptable measure to determine functional ankle instability and its severity. The Persian version of Cumberland Ankle Instability Tool is a valid and reliable tool for clinical and research purpose in Persian-speaking individuals.

  2. Evaluation of tools used to measure critical thinking development in nursing and midwifery undergraduate students: a systematic review.

    Science.gov (United States)

    Carter, Amanda G; Creedy, Debra K; Sidebotham, Mary

    2015-07-01

    Well developed critical thinking skills are essential for nursing and midwifery practices. The development of students' higher-order cognitive abilities, such as critical thinking, is also well recognised in nursing and midwifery education. Measurement of critical thinking development is important to demonstrate change over time and effectiveness of teaching strategies. To evaluate tools designed to measure critical thinking in nursing and midwifery undergraduate students. The following six databases were searched and resulted in the retrieval of 1191 papers: CINAHL, Ovid Medline, ERIC, Informit, PsycINFO and Scopus. After screening for inclusion, each paper was evaluated using the Critical Appraisal Skills Programme Tool. Thirty-four studies met the inclusion criteria and quality appraisal. Sixteen different tools that measure critical thinking were reviewed for reliability and validity and extent to which the domains of critical thinking were evident. Sixty percent of studies utilised one of four standardised commercially available measures of critical thinking. Reliability and validity were not consistently reported and there was a variation in reliability across studies that used the same measure. Of the remaining studies using different tools, there was also limited reporting of reliability making it difficult to assess internal consistency and potential applicability of measures across settings. Discipline specific instruments to measure critical thinking in nursing and midwifery are required, specifically tools that measure the application of critical thinking to practise. Given that critical thinking development occurs over an extended period, measurement needs to be repeated and multiple methods of measurement used over time. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  3. Cross-cultural validation of health literacy measurement tools in Italian oncology patients.

    Science.gov (United States)

    Zotti, Paola; Cocchi, Simone; Polesel, Jerry; Cipolat Mis, Chiara; Bragatto, Donato; Cavuto, Silvio; Conficconi, Alice; Costanzo, Carla; De Giorgi, Melissa; Drace, Christina A; Fiorini, Federica; Gangeri, Laura; Lisi, Andrea; Martino, Rosalba; Mosconi, Paola; Paradiso, Angelo; Ravaioli, Valentina; Truccolo, Ivana; De Paoli, Paolo

    2017-06-19

    The aim of this study was to assess the psychometric characteristics of four Health Literacy (HL) measurement tools, viz. Newest Vital Sign (NVS), Short Test of Functional Health Literacy in Adults (STOFHLA), Single Item Literacy Screener (SILS) and Single question on Self-rated Reading Ability (SrRA) among Italian oncology patients. The original version of the tools were translated from the English language into Italian using a standard forward-backward procedure and according to internationally recognized good practices. Their internal consistency (reliability) and validity (construct, convergent and discriminative) were tested in a sample of 245 consecutive cancer patients recruited from seven Italian health care centers. The internal consistency of the STOFHLA-I was Chronbach's α=0.96 and that of NVS-I was α=0.74. The STOFHLA-I, NVS-I, SILS-I and SrRA-I scores were in a good relative correlation and in all tools the discriminative known-group validity was confirmed. The reliability and validity values were similar to those obtained from other cultural context studies. The psychometric characteristics of the Italian version of NVS, STHOFLA, SILS and SrRA were found to be good, with satisfactory reliability and validity. This indicates that they could be used as a screening tool in Italian patients. Moreover, the use of the same cross-cultural tools, validated in different languages, is essential for implementing multicenter studies to measure and compare the functional HL levels across countries.

  4. Are current psychometric tools suitable for measuring outcomes of diabetes education?

    DEFF Research Database (Denmark)

    Eigenmann, C. A.; Colagiuri, R.; Skinner, T. C.

    2009-01-01

    Aims To critically appraise the suitability, validity, reliability, feasibility and sensitivity to change of available psychometric tools for measuring the education outcomes identified in the (Australian) National Consensus on Outcomes and Indicators for Diabetes Patient Education. Methods Poten...

  5. Inter- and intra-observer reliability of masking in plantar pressure measurement analysis.

    Science.gov (United States)

    Deschamps, K; Birch, I; Mc Innes, J; Desloovere, K; Matricali, G A

    2009-10-01

    Plantar pressure measurement is an important tool in gait analysis. Manual placement of small masks (masking) is increasingly used to calculate plantar pressure characteristics. Little is known concerning the reliability of manual masking. The aim of this study was to determine the reliability of masking on 2D plantar pressure footprints, in a population with forefoot deformity (i.e. hallux valgus). Using a random repeated-measure design, four observers identified the third metatarsal head on a peak-pressure barefoot footprint, using a small mask. Subsequently, the location of all five metatarsal heads was identified, using the same size of masks and the same protocol. The 2D positional variation of the masks and the peak pressure (PP) and pressure time integral (PTI) values of each mask were calculated. For single-masking the lowest inter-observer reliability was found for the distal-proximal direction, causing a clear, adverse impact on the reliability of the pressure characteristics (PP and PTI). In the medial-lateral direction the inter-observer reliability could be scored as high. Intra-observer reliability was better and could be scored as high or good for both directions, with a correlated improved reliability of the pressure characteristics. Reliability of multi-masking showed a similar pattern, but overall values tended to be lower. Therefore, small sized masking in order to define pressure characteristics in the forefoot should be done with care.

  6. Reliability of Instruments Measuring At-Risk and Problem Gambling Among Young Individuals

    DEFF Research Database (Denmark)

    Edgren, Robert; Castrén, Sari; Mäkelä, Marjukka

    2016-01-01

    This review aims to clarify which instruments measuring at-risk and problem gambling (ARPG) among youth are reliable and valid in light of reported estimates of internal consistency, classification accuracy, and psychometric properties. A systematic search was conducted in PubMed, Medline, and Psyc......Info covering the years 2009–2015. In total, 50 original research articles fulfilled the inclusion criteria: target age under 29 years, using an instrument designed for youth, and reporting a reliability estimate. Articles were evaluated with the revised Quality Assessment of Diagnostic Accuracy Studies tool....... Reliability estimates were reported for five ARPG instruments. Most studies (66%) evaluated the South Oaks Gambling Screen Revised for Adolescents. The Gambling Addictive Behavior Scale for Adolescents was the only novel instrument. In general, the evaluation of instrument reliability was superficial. Despite...

  7. Reliability of Two Smartphone Applications for Radiographic Measurements of Hallux Valgus Angles.

    Science.gov (United States)

    Mattos E Dinato, Mauro Cesar; Freitas, Marcio de Faria; Milano, Cristiano; Valloto, Elcio; Ninomiya, André Felipe; Pagnano, Rodrigo Gonçalves

    The objective of the present study was to assess the reliability of 2 smartphone applications compared with the traditional goniometer technique for measurement of radiographic angles in hallux valgus and the time required for analysis with the different methods. The radiographs of 31 patients (52 feet) with a diagnosis of hallux valgus were analyzed. Four observers, 2 with >10 years' experience in foot and ankle surgery and 2 in-training surgeons, measured the hallux valgus angle and intermetatarsal angle using a manual goniometer technique and 2 smartphone applications (Hallux Angles and iPinPoint). The interobserver and intermethod reliability were estimated using intraclass correlation coefficients (ICCs), and the time required for measurement of the angles among the 3 methods was compared using the Friedman test. A very good or good interobserver reliability was found among the 4 observers measuring the hallux valgus angle and intermetatarsal angle using the goniometer (ICC 0.913 and 0.821, respectively) and iPinPoint (ICC 0.866 and 0.638, respectively). Using the Hallux Angles application, a very good interobserver reliability was found for measurements of the hallux valgus angle (ICC 0.962) and intermetatarsal angle (ICC 0.935) only among the more experienced observers. The time required for the measurements was significantly shorter for the measurements using both smartphone applications compared with the goniometer method. One smartphone application (iPinPoint) was reliable for measurements of the hallux valgus angles by either experienced or nonexperienced observers. The use of these tools might save time in the evaluation of radiographic angles in the hallux valgus. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Measuring awareness of financial skills: reliability and validity of a new measure.

    Science.gov (United States)

    Cramer, K; Tuokko, H A; Mateer, C A; Hultsch, D F

    2004-03-01

    This paper examines the psychometric properties of a three-part (participant, informant, and performance) Measure for assessing Awareness of Financial Skills (MAFS). The MAFS was administered to 10 seniors with dementia and 25 well-functioning seniors, and their informants. Measures of cognitive functioning, social desirability, neuroticism, and perceived control were administered to each participant to allow for an assessment of validity. Internal consistency estimates for the participant and informant questionnaires were found to be 0.92 and 0.97, respectively. Convergent validity analysis indicated that performance on this measure was related to level of cognitive functioning, with higher level of unawareness associated with decreased cognitive ability. Discriminant validity analysis showed that performance on this measure was not related to social desirability or neuroticism. This study provides evidence that the MAFS is a reliable and valid tool for assessing awareness of financial skills in older adults.

  9. Development and evaluation of a patient-centred measurement tool for surgeons' non-technical skills.

    Science.gov (United States)

    Yule, J; Hill, K; Yule, S

    2018-06-01

    Non-technical skills are essential for safe and effective surgery. Several tools to assess surgeons' non-technical skills from the clinician's perspective have been developed. However, a reliable measurement tool using a patient-centred approach does not currently exist. The aim of this study was to translate the existing Non-Technical Skills for Surgeons (NOTSS) tool into a patient-centred evaluation tool. Data were gathered from four cohorts of patients using an iterative four-stage mixed-methods research design. Exploratory and confirmatory factor analyses were performed to establish the psychometric properties of the tool, focusing on validity, reliability, usability and parsimony. Some 534 patients were recruited to the study. A total of 24 patient-centred non-technical skill items were developed in stage 1, and reduced to nine items in stage 2 using exploratory factor analysis. In stage 3, confirmatory factor analysis demonstrated that these nine items each loaded on to one of three factors, with excellent internal consistency: decision-making, leadership, and communication and teamwork. In stage 4, validity testing established that the new tool was independent of physician empathy and predictive of surgical quality. Surgical leadership emerged as the most dominant skill that patients could recognize and evaluate. A novel nine-item assessment tool has been developed. The Patients' Evaluation of Non-Technical Skills (PENTS) tool allows valid and reliable measurement of surgeons' non-technical skills from the patient perspective. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.

  10. Validating a tool to measure auxiliary nurse midwife and nurse motivation in rural Nepal.

    Science.gov (United States)

    Morrison, Joanna; Batura, Neha; Thapa, Rita; Basnyat, Regina; Skordis-Worrall, Jolene

    2015-05-12

    A global shortage of health workers in rural areas increases the salience of motivating and supporting existing health workers. Understandings of motivation may vary in different settings, and it is important to use measurement methods that are contextually appropriate. We identified a measurement tool, previously used in Kenya, and explored its validity and reliability to measure the motivation of auxiliary nurse midwives (ANM) and staff nurses (SN) in rural Nepal. Qualitative and quantitative methods were used to assess the content validity, the construct validity, the internal consistency and the reliability of the tool. We translated the tool into Nepali and it was administered to 137 ANMs and SNs in three districts. We collected qualitative data from 78 nursing personnel and district- and central-level stakeholders using interviews and focus group discussions. We calculated motivation scores for ANMs and SNs using the quantitative data and conducted statistical tests for validity and reliability. Motivation scores were compared with qualitative data. Descriptive exploratory analysis compared mean motivation scores by ANM and SN sociodemographic characteristics. The concept of self-efficacy was added to the tool before data collection. Motivation was revealed through conscientiousness. Teamwork and the exertion of extra effort were not adequately captured by the tool, but important in illustrating motivation. The statement on punctuality was problematic in quantitative analysis, and attendance was more expressive of motivation. The calculated motivation scores usually reflected ANM and SN interview data, with some variation in other stakeholder responses. The tool scored within acceptable limits in validity and reliability testing and was able to distinguish motivation of nursing personnel with different sociodemographic characteristics. We found that with minor modifications, the tool provided valid and internally consistent measures of motivation among ANMs

  11. PredicForex. A tool for a reliable market. Playing with currencies.

    Directory of Open Access Journals (Sweden)

    C. Cortés Velasco

    2009-12-01

    Full Text Available The Forex market is a very interesting market. Finding a suitable tool to forecast currency behavior will be of great interest. It is almost impossible to find a 100 % reliable tool. This market is like any other one, unpredictable. However we developed a very interesting tool that makes use of WebCrawler, data mining and web services to offer and forecast an advice to any user or broker.

  12. Design for Reliability and Robustness Tool Platform for Power Electronic Systems – Study Case on Motor Drive Applications

    DEFF Research Database (Denmark)

    Vernica, Ionut; Wang, Huai; Blaabjerg, Frede

    2018-01-01

    conventional approach, mainly based on failure statistics from the field, the reliability evaluation of the power devices is still a challenging task. In order to address the given problem, a MATLAB based reliability assessment tool has been developed. The Design for Reliability and Robustness (DfR2) tool...... allows the user to easily investigate the reliability performance of the power electronic components (or sub-systems) under given input mission profiles and operating conditions. The main concept of the tool and its framework are introduced, highlighting the reliability assessment procedure for power...... semiconductor devices. Finally, a motor drive application is implemented and the reliability performance of the power devices is investigated with the help of the DfR2 tool, and the resulting reliability metrics are presented....

  13. A Reliable Measure of Information Security Awareness and the Identification of Bias in Responses

    Directory of Open Access Journals (Sweden)

    Agata McCormac

    2017-11-01

    Full Text Available The Human Aspects of Information Security Questionnaire (HAIS-Q is designed to measure Information Security Awareness. More specifically, the tool measures an individual’s knowledge, attitude, and self-reported behaviour relating to information security in the workplace. This paper reports on the reliability of the HAIS-Q, including test-retest reliability and internal consistency. The paper also assesses the reliability of three preliminary over-claiming items, designed specifically to complement the HAIS-Q, and identify those individuals who provide socially desirable responses. A total of 197 working Australians completed two iterations of the HAIS-Q and the over-claiming items, approximately 4 weeks apart. Results of the analysis showed that the HAIS-Q was externally reliable and internally consistent. Therefore, the HAIS-Q can be used to reliably measure information security awareness. Reliability testing on the preliminary over-claiming items was not as robust and further development is required and recommended. The implications of these findings mean that organisations can confidently use the HAIS-Q to not only measure the current state of employee information security awareness within their organisation, but they can also measure the effectiveness and impacts of training interventions, information security awareness programs and campaigns. The influence of cultural changes and the effect of security incidents can also be assessed.

  14. The design and use of reliability data base with analysis tool

    Energy Technology Data Exchange (ETDEWEB)

    Doorepall, J.; Cooke, R.; Paulsen, J.; Hokstadt, P.

    1996-06-01

    With the advent of sophisticated computer tools, it is possible to give a distributed population of users direct access to reliability component operational histories. This allows the user a greater freedom in defining statistical populations of components and selecting failure modes. However, the reliability data analyst`s current analytical instrumentarium is not adequate for this purpose. The terminology used in organizing and gathering reliability data is standardized, and the statistical methods used in analyzing this data are not always suitably chosen. This report attempts to establish a baseline with regard to terminology and analysis methods, to support the use of a new analysis tool. It builds on results obtained in several projects for the ESTEC and SKI on the design of reliability databases. Starting with component socket time histories, we identify a sequence of questions which should be answered prior to the employment of analytical methods. These questions concern the homogeneity and stationarity of (possible dependent) competing failure modes and the independence of competing failure modes. Statistical tests, some of them new, are proposed for answering these questions. Attention is given to issues of non-identifiability of competing risk and clustering of failure-repair events. These ideas have been implemented in an analysis tool for grazing component socket time histories, and illustrative results are presented. The appendix provides background on statistical tests and competing failure modes. (au) 4 tabs., 17 ills., 61 refs.

  15. The design and use of reliability data base with analysis tool

    International Nuclear Information System (INIS)

    Doorepall, J.; Cooke, R.; Paulsen, J.; Hokstadt, P.

    1996-06-01

    With the advent of sophisticated computer tools, it is possible to give a distributed population of users direct access to reliability component operational histories. This allows the user a greater freedom in defining statistical populations of components and selecting failure modes. However, the reliability data analyst's current analytical instrumentarium is not adequate for this purpose. The terminology used in organizing and gathering reliability data is standardized, and the statistical methods used in analyzing this data are not always suitably chosen. This report attempts to establish a baseline with regard to terminology and analysis methods, to support the use of a new analysis tool. It builds on results obtained in several projects for the ESTEC and SKI on the design of reliability databases. Starting with component socket time histories, we identify a sequence of questions which should be answered prior to the employment of analytical methods. These questions concern the homogeneity and stationarity of (possible dependent) competing failure modes and the independence of competing failure modes. Statistical tests, some of them new, are proposed for answering these questions. Attention is given to issues of non-identifiability of competing risk and clustering of failure-repair events. These ideas have been implemented in an analysis tool for grazing component socket time histories, and illustrative results are presented. The appendix provides background on statistical tests and competing failure modes. (au) 4 tabs., 17 ills., 61 refs

  16. Relative and Absolute Reliability of the Professionalism in Physical Therapy Core Values Self-Assessment Tool.

    Science.gov (United States)

    Furgal, Karen E; Norris, Elizabeth S; Young, Sonia N; Wallmann, Harvey W

    2018-01-01

    Development of professional behaviors in Doctor of Physical Therapy (DPT) students is an important part of professional education. The American Physical Therapy Association (APTA) has developed the Professionalism in Physical Therapy Core Values Self-Assessment (PPTCV-SA) tool to increase awareness of personal values in practice. The PPTCV-SA has been used to measure growth in professionalism following a clinical or educational experience. There are few studies reporting psychometric properties of the PPTCV-SA. The purpose of this study was to establish properties of relative reliability (intraclass correlation coefficient, iCC) and absolute reliability (standard error of measurement, SEM; minimal detectable change, MDC) of the PPTCV-SA. in this project, 29 first-year students in a DPT program were administered the PPTCVA-SA on two occasions, 2 weeks apart. Paired t-tests were used to examine stability in PPTCV-SA scores on the two occasions. iCCs were calculated as a measure of relative reliability and for use in the calculation of the absolute reliability measures of SEM and MDC. Results of paired t-tests indicated differences in the subscale scores between times 1 and 2 were non-significant, except for three subscales: Altruism (p=0.01), Excellence (p=0.05), and Social Responsibility (p=0.02). iCCs for test-retest reliability were moderate-to-good for all subscales, with SEMs ranging from 0.30 to 0.62, and MDC95 ranging from 0.83 to 1.71. These results can guide educators and researchers when determining the likelihood of true change in professionalism following a professional development activity.

  17. Reliability and validity of non-radiographic methods of thoracic kyphosis measurement: a systematic review.

    Science.gov (United States)

    Barrett, Eva; McCreesh, Karen; Lewis, Jeremy

    2014-02-01

    A wide array of instruments are available for non-invasive thoracic kyphosis measurement. Guidelines for selecting outcome measures for use in clinical and research practice recommend that properties such as validity and reliability are considered. This systematic review reports on the reliability and validity of non-invasive methods for measuring thoracic kyphosis. A systematic search of 11 electronic databases located studies assessing reliability and/or validity of non-invasive thoracic kyphosis measurement techniques. Two independent reviewers used a critical appraisal tool to assess the quality of retrieved studies. Data was extracted by the primary reviewer. The results were synthesized qualitatively using a level of evidence approach. 27 studies satisfied the eligibility criteria and were included in the review. The reliability, validity and both reliability and validity were investigated by sixteen, two and nine studies respectively. 17/27 studies were deemed to be of high quality. In total, 15 methods of thoracic kyphosis were evaluated in retrieved studies. All investigated methods showed high (ICC ≥ .7) to very high (ICC ≥ .9) levels of reliability. The validity of the methods ranged from low to very high. The strongest levels of evidence for reliability exists in support of the Debrunner kyphometer, Spinal Mouse and Flexicurve index, and for validity supports the arcometer and Flexicurve index. Further reliability and validity studies are required to strengthen the level of evidence for the remaining methods of measurement. This should be addressed by future research. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Sensitivity, reliability and the effects of diurnal variation on a test battery of field usable upper limb fatigue measures.

    Science.gov (United States)

    Yung, Marcus; Wells, Richard P

    2017-07-01

    Fatigue has been linked to deficits in production quality and productivity and, if of long duration, work-related musculoskeletal disorders. It may thus be a useful risk indicator and design and evaluation tool. However, there is limited information on the test-retest reliability, the sensitivity and the effects of diurnal fluctuation on field usable fatigue measures. This study reports on an evaluation of 11 measurement tools and their 14 parameters. Eight measures were found to have test-retest ICC values greater than 0.8. Four measures were particularly responsive during an intermittent fatiguing condition. However, two responsive measures demonstrated rhythmic behaviour, with significant time effects from 08:00 to mid-afternoon and early evening. Action tremor, muscle mechanomyography and perceived fatigue were found to be most reliable and most responsive; but additional analytical considerations might be required when interpreting daylong responses of MMG and action tremor. Practitioner Summary: This paper presents findings from test-retest and daylong reliability and responsiveness evaluations of 11 fatigue measures. This paper suggests that action tremor, muscle mechanomyography and perceived fatigue were most reliable and most responsive. However, mechanomyography and action tremor may be susceptible to diurnal changes.

  19. Knowledge modelling and reliability processing: presentation of the Figaro language and associated tools

    International Nuclear Information System (INIS)

    Bouissou, M.; Villatte, N.; Bouhadana, H.; Bannelier, M.

    1991-12-01

    EDF has been developing for several years an integrated set of knowledge-based and algorithmic tools for automation of reliability assessment of complex (especially sequential) systems. In this environment, the reliability expert has at his disposal all the powerful software tools for qualitative and quantitative processing, besides he gets various means to generate automatically the inputs for these tools, through the acquisition of graphical data. The development of these tools has been based on FIGARO, a specific language, which was built to get an homogeneous system modelling. Various compilers and interpreters get a FIGARO model into conventional models, such as fault-trees, Markov chains, Petri Networks. In this report, we introduce the main basics of FIGARO language, illustrating them with examples

  20. Preliminary testing of the reliability and feasibility of SAGE: a system to measure and score engagement with and use of research in health policies and programs.

    Science.gov (United States)

    Makkar, Steve R; Williamson, Anna; D'Este, Catherine; Redman, Sally

    2017-12-19

    Few measures of research use in health policymaking are available, and the reliability of such measures has yet to be evaluated. A new measure called the Staff Assessment of Engagement with Evidence (SAGE) incorporates an interview that explores policymakers' research use within discrete policy documents and a scoring tool that quantifies the extent of policymakers' research use based on the interview transcript and analysis of the policy document itself. We aimed to conduct a preliminary investigation of the usability, sensitivity, and reliability of the scoring tool in measuring research use by policymakers. Nine experts in health policy research and two independent coders were recruited. Each expert used the scoring tool to rate a random selection of 20 interview transcripts, and each independent coder rated 60 transcripts. The distribution of scores among experts was examined, and then, interrater reliability was tested within and between the experts and independent coders. Average- and single-measure reliability coefficients were computed for each SAGE subscales. Experts' scores ranged from the limited to extensive scoring bracket for all subscales. Experts as a group also exhibited at least a fair level of interrater agreement across all subscales. Single-measure reliability was at least fair except for three subscales: Relevance Appraisal, Conceptual Use, and Instrumental Use. Average- and single-measure reliability among independent coders was good to excellent for all subscales. Finally, reliability between experts and independent coders was fair to excellent for all subscales. Among experts, the scoring tool was comprehensible, usable, and sensitive to discriminate between documents with varying degrees of research use. Secondly, the scoring tool yielded scores with good reliability among the independent coders. There was greater variability among experts, although as a group, the tool was fairly reliable. The alignment between experts' and independent

  1. The Managing Emergencies in Paediatric Anaesthesia global rating scale is a reliable tool for simulation-based assessment in pediatric anesthesia crisis management.

    Science.gov (United States)

    Everett, Tobias C; Ng, Elaine; Power, Daniel; Marsh, Christopher; Tolchard, Stephen; Shadrina, Anna; Bould, Matthew D

    2013-12-01

    The use of simulation-based assessments for high-stakes physician examinations remains controversial. The Managing Emergencies in Paediatric Anaesthesia course uses simulation to teach evidence-based management of anesthesia crises to trainee anesthetists in the United Kingdom (UK) and Canada. In this study, we investigated the feasibility and reliability of custom-designed scenario-specific performance checklists and a global rating scale (GRS) assessing readiness for independent practice. After research ethics board approval, subjects were videoed managing simulated pediatric anesthesia crises in a single Canadian teaching hospital. Each subject was randomized to two of six different scenarios. All 60 scenarios were subsequently rated by four blinded raters (two in the UK, two in Canada) using the checklists and GRS. The actual and predicted reliability of the tools was calculated for different numbers of raters using the intraclass correlation coefficient (ICC) and the Spearman-Brown prophecy formula. Average measures ICCs ranged from 'substantial' to 'near perfect' (P ≤ 0.001). The reliability of the checklists and the GRS was similar. Single measures ICCs showed more variability than average measures ICC. At least two raters would be required to achieve acceptable reliability. We have established the reliability of a GRS to assess the management of simulated crisis scenarios in pediatric anesthesia, and this tool is feasible within the setting of a research study. The global rating scale allows raters to make a judgement regarding a participant's readiness for independent practice. These tools may be used in the future research examining simulation-based assessment. © 2013 John Wiley & Sons Ltd.

  2. Systematic Review of the Measurement Properties of Tools Used to Measure Behaviour Problems in Young Children with Autism.

    Science.gov (United States)

    Hanratty, Jennifer; Livingstone, Nuala; Robalino, Shannon; Terwee, Caroline B; Glod, Magdalena; Oono, Inalegwu P; Rodgers, Jacqui; Macdonald, Geraldine; McConachie, Helen

    2015-01-01

    Behaviour problems are common in young children with autism spectrum disorder (ASD). There are many different tools used to measure behavior problems but little is known about their validity for the population. To evaluate the measurement properties of behaviour problems tools used in evaluation of intervention or observational research studies with children with ASD up to the age of six years. Behaviour measurement tools were identified as part of a larger, two stage, systematic review. First, sixteen major electronic databases, as well as grey literature and research registers were searched, and tools used listed and categorized. Second, using methodological filters, we searched for articles examining the measurement properties of the tools in use with young children with ASD in ERIC, MEDLINE, EMBASE, CINAHL, and PsycINFO. The quality of these papers was then evaluated using the COSMIN checklist. We identified twelve tools which had been used to measure behaviour problems in young children with ASD, and fifteen studies which investigated the measurement properties of six of these tools. There was no evidence available for the remaining six tools. Two questionnaires were found to be the most robust in their measurement properties, the Child Behavior Checklist and the Home Situations Questionnaire-Pervasive Developmental Disorders version. We found patchy evidence on reliability and validity, for only a few of the tools used to measure behaviour problems in young children with ASD. More systematic research is required on measurement properties of tools for use in this population, in particular to establish responsiveness to change which is essential in measurement of outcomes of intervention. CRD42012002223.

  3. Reliability of cervical lordosis and global sagittal spinal balance measurements in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Vidal, Christophe; Ilharreborde, Brice; Azoulay, Robin; Sebag, Guy; Mazda, Keyvan

    2013-06-01

    Radiological reproducibility study. To assess intra and interobserver reliability of radiographic measurements for global sagittal balance parameters and sagittal spine curves, including cervical spine. Sagittal spine balance in adolescent idiopathic scoliosis (AIS) is a main issue and many studies have been reported, showing that coronal and sagittal deformities often involve sagittal cervical unbalance. Global sagittal balance aims to obtain a horizontal gaze and gravity line at top of hips when subject is in a static position, involving adjustment of each spine curvature in the sagittal plane. To our knowledge, no study did use a methodologically validated imaging analysis tool able to appreciate sagittal spine contours and distances in AIS and especially in the cervical region. Lateral full-spine low-dose EOS radiographs were performed in 75 patients divided in three groups (control subjects, AIS, operated AIS). Three observers digitally analyzed twice each radiograph and 11 sagittal measures were collected for each image. Reliability was assessed calculating intraobserver Pearson's r correlation coefficient, interobserver intra-class correlation coefficient (ICC) completed with a two-by-two Bland-Altman plot analysis. This measurement method has shown excellent intra and interobserver reliability in all parameters, sagittal curvatures, pelvic parameters and global sagittal balance. This study validated a simple and efficient tool in AIS sagittal contour analysis. It defined new relevant landmarks allowing to characterize cervical segmental curvatures and cervical involvement in global balance.

  4. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 4: HARP Output (HARPO) graphics display user's guide

    Science.gov (United States)

    Sproles, Darrell W.; Bavuso, Salvatore J.

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical postprocessor program HARPO (HARP Output). HARPO reads ASCII files generated by HARP. It provides an interactive plotting capability that can be used to display alternate model data for trade-off analyses. File data can also be imported to other commercial software programs.

  5. Assessing physiotherapists' communication skills for promoting patient autonomy for self-management: reliability and validity of the communication evaluation in rehabilitation tool.

    Science.gov (United States)

    Murray, Aileen; Hall, Amanda; Williams, Geoffrey C; McDonough, Suzanne M; Ntoumanis, Nikos; Taylor, Ian; Jackson, Ben; Copsey, Bethan; Hurley, Deirdre A; Matthews, James

    2018-02-27

    To assess the inter-rater reliability and concurrent validity of the Communication Evaluation in Rehabilitation Tool, which aims to externally assess physiotherapists competency in using Self-Determination Theory-based communication strategies in practice. Audio recordings of initial consultations between 24 physiotherapists and 24 patients with chronic low back pain in four hospitals in Ireland were obtained as part of a larger randomised controlled trial. Three raters, all of whom had Ph.Ds in psychology and expertise in motivation and physical activity, independently listened to the 24 audio recordings and completed the 18-item Communication Evaluation in Rehabilitation Tool. Inter-rater reliability between all three raters was assessed using intraclass correlation coefficients. Concurrent validity was assessed using Pearson's r correlations with a reference standard, the Health Care Climate Questionnaire. The total score for the Communication Evaluation in Rehabilitation Tool is an average of all 18 items. Total scores demonstrated good inter-rater reliability (Intraclass Correlation Coefficient (ICC) = 0.8) and concurrent validity with the Health Care Climate Questionnaire total score (range: r = 0.7-0.88). Item-level scores of the Communication Evaluation in Rehabilitation Tool identified five items that need improvement. Results provide preliminary evidence to support future use and testing of the Communication Evaluation in Rehabilitation Tool. Implications for Rehabilitation Promoting patient autonomy is a learned skill and while interventions exist to train clinicians in these skills there are no tools to assess how well clinicians use these skills when interacting with a patient. The lack of robust assessment has severe implications regarding both the fidelity of clinician training packages and resulting outcomes for promoting patient autonomy. This study has developed a novel measurement tool Communication Evaluation in Rehabilitation Tool and a

  6. Reliability of smartphone-based gait measurements for quantification of physical activity/inactivity levels.

    Science.gov (United States)

    Ebara, Takeshi; Azuma, Ryohei; Shoji, Naoto; Matsukawa, Tsuyoshi; Yamada, Yasuyuki; Akiyama, Tomohiro; Kurihara, Takahiro; Yamada, Shota

    2017-11-25

    Objective measurements using built-in smartphone sensors that can measure physical activity/inactivity in daily working life have the potential to provide a new approach to assessing workers' health effects. The aim of this study was to elucidate the characteristics and reliability of built-in step counting sensors on smartphones for development of an easy-to-use objective measurement tool that can be applied in ergonomics or epidemiological research. To evaluate the reliability of step counting sensors embedded in seven major smartphone models, the 6-minute walk test was conducted and the following analyses of sensor precision and accuracy were performed: 1) relationship between actual step count and step count detected by sensors, 2) reliability between smartphones of the same model, and 3) false detection rates when sitting during office work, while riding the subway, and driving. On five of the seven models, the inter-class correlations coefficient (ICC (3,1) ) showed high reliability with a range of 0.956-0.993. The other two models, however, had ranges of 0.443-0.504 and the relative error ratios of the sensor-detected step count to the actual step count were ±48.7%-49.4%. The level of agreement between the same models was ICC (3,1) : 0.992-0.998. The false detection rates differed between the sitting conditions. These results suggest the need for appropriate regulation of step counts measured by sensors, through means such as correction or calibration with a predictive model formula, in order to obtain the highly reliable measurement results that are sought in scientific investigation.

  7. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 3: HARP Graphics Oriented (GO) input user's guide

    Science.gov (United States)

    Bavuso, Salvatore J.; Rothmann, Elizabeth; Mittal, Nitin; Koppen, Sandra Howell

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems, and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical preprocessor Graphics Oriented (GO) program. GO is a graphical user interface for the HARP engine that enables the drawing of reliability/availability models on a monitor. A mouse is used to select fault tree gates or Markov graphical symbols from a menu for drawing.

  8. Quantitative measurement of hypertrophic scar: intrarater reliability, sensitivity, and specificity.

    Science.gov (United States)

    Nedelec, Bernadette; Correa, José A; Rachelska, Grazyna; Armour, Alexis; LaSalle, Léo

    2008-01-01

    The comparison of scar evaluation over time requires measurement tools with acceptable intrarater reliability and the ability to discriminate skin characteristics of interest. The objective of this study was to evaluate the intrarater reliability and sensitivity and specificity of the Cutometer, the Mexameter, and the DermaScan C relative to the modified Vancouver Scar Scale (mVSS) in patient-matched normal skin, normal scar (donor sites), and hypertrophic scar (HSc). A single investigator evaluated four tissue types (severe HSc, less severe HSc, donor site, and normal skin) in 30 burn survivors with all four measurement tools. The intraclass correlation coefficient (ICC) for the Cutometer was acceptable (> or =0.75) for the maximum deformation measure for the donor site and normal skin (>0.78) but was below the acceptable range for the HSc sites and all other parameters. The ICC for the Mexameter erythema (>0.75) and melanin index (>0.89) and the DermaScan C total thickness measurement (>0.82) were acceptable for all sites. The ICC for the total of the height, pliability, and vascularity subscales of the mVSS was acceptable (0.81) for normal scar but below the acceptable range for the scar sites. The DermaScan C was clearly able to discriminate HSc from normal scar and normal skin based on the total thickness measure. The Cutometer was less discriminating but was still able to discriminate HSc from normal scar and normal skin. The Mexameter erythema index was not a good discriminator of HSc and normal scar. Receiver operating characteristic curves were generated to establish the best cutoff point for the DermaScan C total thickness and the Cutometer maximum deformation, which were 2.034 and 0.387 mm, respectively. This study showed that although the Cutometer, the DermaScan C, and the Mexameter have measurement properties that make them attractive substitutes for the mVSS, caution must be used when interpreting results since the Cutometer has a ceiling effect when

  9. Reliability measures in managing GI bleeding.

    Science.gov (United States)

    Sonnenberg, Amnon

    2012-06-01

    Multiple procedures and devices are used in a complex interplay to diagnose and treat GI bleeding. To model how a large variety of diagnostic and therapeutic components interact in the successful management of GI bleeding. The analysis uses the concept of reliability block diagrams from probability theory to model management outcome. Separate components of the management process are arranged in a serial or parallel fashion. If the outcome depends on the function of each component individually, such components are modeled to be arranged in series. If components complement each other and can mutually compensate for each of their failures, such components are arranged in a parallel fashion. General endoscopy practice. Patients with GI bleeding of unknown etiology. All available endoscopic and radiographic means to diagnose and treat GI bleeding. Process reliability in achieving hemostasis. Serial arrangements tend to reduce process reliability, whereas parallel arrangements increase it. Whenever possible, serial components should be bridged and complemented by additional alternative (parallel) routes of operation. Parallel components with low individual reliability can still contribute to overall process reliability as long as they function independently of other pre-existing alternatives. Probability of success associated with individual components is partly unknown. Modeling management of GI bleeding by a reliability block diagram provides a useful tool in assessing the impact of individual endoscopic techniques and administrative structures on the overall outcome. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  10. Reliability Of Kraus-Weber Exercise Test As An Evaluation Tool In ...

    African Journals Online (AJOL)

    Reliability Of Kraus-Weber Exercise Test As An Evaluation Tool In Low Back ... strength and flexibility of the back, abdominal, psoas and hamstring muscles. ... Keywords: Kraus-Weber test, low back pain, muscle flexibility, muscle strength.

  11. Reliability of biceps femoris and semitendinosus muscle architecture measurements obtained with ultrasonography

    Directory of Open Access Journals (Sweden)

    Viviane Bastos de Oliveira

    Full Text Available Introduction Currently, little attention is given to the muscle architecture reliability studies of the hamstring using a robust statistical. Our purpose was to determine the reliability of ultrasound measurements of muscle thickness, fascicle length and pennation angle of the biceps femoris and semitendinosus muscles, including heteroskedasticity and internal consistency analyses. Methods Two images of biceps femoris and semitendinosus at 50% of the thigh length were acquired from 21 volunteers, in two visits. The parameters were measured three times in each image, and for each muscle. The reliability was analyzed by the intraclass correlation coefficient (ICC and Cronbach’s alpha (αCronbach. The relative standard error of the measurements (%SEM were calculated and Bland-Altman plots were generated. Results All parameters presented excellent ICC for the three repeated measurements (ICC from 0.93 ‒ 0.99 and moderate to excellent reliability intraday (ICC from 0.70 ‒ 0.95 for both muscles. The present study indicates that ultrasound is a reliable tool to estimate the biceps femoris fascicle length (ICC = 0.97, αCronbach = 0.98, %SEM = 7.86 and semitendinosus (ICC = 0.90, αCronbach = 0.95, %SEM = 7.55, as well as the biceps femoris muscle thickness (ICC = 0.89, αCronbach = 0.94, %SEM = 10.23 and semitendinosus muscle thickness (ICC = 0.87, αCronbach = 0.93, %SEM = 1.35. At last, biceps femoris pennation angle (ICC = 0.93, αCronbach = 0.96 and %SEM = 4.36 and semitendinosus (ICC = 0.96, αCronbach = 0.98 and %SEM = 4.25 also had good repeatability. Conclusion Ultrasonography show good repeatability in estimating of muscle architecture parameters.

  12. Systematic Review of the Measurement Properties of Tools Used to Measure Behaviour Problems in Young Children with Autism

    Science.gov (United States)

    Hanratty, Jennifer; Livingstone, Nuala; Robalino, Shannon; Terwee, Caroline B.; Glod, Magdalena; Oono, Inalegwu P.; Rodgers, Jacqui; Macdonald, Geraldine; McConachie, Helen

    2015-01-01

    Background Behaviour problems are common in young children with autism spectrum disorder (ASD). There are many different tools used to measure behavior problems but little is known about their validity for the population. Objectives To evaluate the measurement properties of behaviour problems tools used in evaluation of intervention or observational research studies with children with ASD up to the age of six years. Methods Behaviour measurement tools were identified as part of a larger, two stage, systematic review. First, sixteen major electronic databases, as well as grey literature and research registers were searched, and tools used listed and categorized. Second, using methodological filters, we searched for articles examining the measurement properties of the tools in use with young children with ASD in ERIC, MEDLINE, EMBASE, CINAHL, and PsycINFO. The quality of these papers was then evaluated using the COSMIN checklist. Results We identified twelve tools which had been used to measure behaviour problems in young children with ASD, and fifteen studies which investigated the measurement properties of six of these tools. There was no evidence available for the remaining six tools. Two questionnaires were found to be the most robust in their measurement properties, the Child Behavior Checklist and the Home Situations Questionnaire—Pervasive Developmental Disorders version. Conclusions We found patchy evidence on reliability and validity, for only a few of the tools used to measure behaviour problems in young children with ASD. More systematic research is required on measurement properties of tools for use in this population, in particular to establish responsiveness to change which is essential in measurement of outcomes of intervention. PROSPERO Registration Number CRD42012002223 PMID:26659821

  13. The Surgical Safety Checklist and Teamwork Coaching Tools: a study of inter-rater reliability.

    Science.gov (United States)

    Huang, Lyen C; Conley, Dante; Lipsitz, Stu; Wright, Christopher C; Diller, Thomas W; Edmondson, Lizabeth; Berry, William R; Singer, Sara J

    2014-08-01

    To assess the inter-rater reliability (IRR) of two novel observation tools for measuring surgical safety checklist performance and teamwork. Data surgical safety checklists can promote adherence to standards of care and improve teamwork in the operating room. Their use has been associated with reductions in mortality and other postoperative complications. However, checklist effectiveness depends on how well they are performed. Authors from the Safe Surgery 2015 initiative developed a pair of novel observation tools through literature review, expert consultation and end-user testing. In one South Carolina hospital participating in the initiative, two observers jointly attended 50 surgical cases and independently rated surgical teams using both tools. We used descriptive statistics to measure checklist performance and teamwork at the hospital. We assessed IRR by measuring percent agreement, Cohen's κ, and weighted κ scores. The overall percent agreement and κ between the two observers was 93% and 0.74 (95% CI 0.66 to 0.79), respectively, for the Checklist Coaching Tool and 86% and 0.84 (95% CI 0.77 to 0.90) for the Surgical Teamwork Tool. Percent agreement for individual sections of both tools was 79% or higher. Additionally, κ scores for six of eight sections on the Checklist Coaching Tool and for two of five domains on the Surgical Teamwork Tool achieved the desired 0.7 threshold. However, teamwork scores were high and variation was limited. There were no significant changes in the percent agreement or κ scores between the first 10 and last 10 cases observed. Both tools demonstrated substantial IRR and required limited training to use. These instruments may be used to observe checklist performance and teamwork in the operating room. However, further refinement and calibration of observer expectations, particularly in rating teamwork, could improve the utility of the tools. Published by the BMJ Publishing Group Limited. For permission to use (where not already

  14. Reliability of risk assessment measures used in sexually violent predator proceedings.

    Science.gov (United States)

    Miller, Cailey S; Kimonis, Eva R; Otto, Randy K; Kline, Suzonne M; Wasserman, Adam L

    2012-12-01

    The field interrater reliability of three assessment tools frequently used by mental health professionals when evaluating sex offenders' risk for reoffending--the Psychopathy Checklist-Revised (PCL-R), the Minnesota Sex Offender Screening Tool-Revised (MnSOST-R) and the Static-99-was examined within the context of sexually violent predator program proceedings. Rater agreement was highest for the Static--99 (intraclass correlation coefficient [ICC₁] = .78) and lowest for the PCL-R (ICC₁ = .60; MnSOST-R ICC₁ = .74), although all instruments demonstrated lower field reliability than that reported in their test manuals. Findings raise concerns about the reliability of risk assessment tools that are used to inform judgments of risk in high-stake sexually violent predator proceedings. Implications for future research and suggestions for improving evaluator training to increase accuracy when informing legal decision making are discussed.

  15. MEASUREMENT: ACCOUNTING FOR RELIABILITY IN PERFORMANCE ESTIMATES.

    Science.gov (United States)

    Waterman, Brian; Sutter, Robert; Burroughs, Thomas; Dunagan, W Claiborne

    2014-01-01

    When evaluating physician performance measures, physician leaders are faced with the quandary of determining whether departures from expected physician performance measurements represent a true signal or random error. This uncertainty impedes the physician leader's ability and confidence to take appropriate performance improvement actions based on physician performance measurements. Incorporating reliability adjustment into physician performance measurement is a valuable way of reducing the impact of random error in the measurements, such as those caused by small sample sizes. Consequently, the physician executive has more confidence that the results represent true performance and is positioned to make better physician performance improvement decisions. Applying reliability adjustment to physician-level performance data is relatively new. As others have noted previously, it's important to keep in mind that reliability adjustment adds significant complexity to the production, interpretation and utilization of results. Furthermore, the methods explored in this case study only scratch the surface of the range of available Bayesian methods that can be used for reliability adjustment; further study is needed to test and compare these methods in practice and to examine important extensions for handling specialty-specific concerns (e.g., average case volumes, which have been shown to be important in cardiac surgery outcomes). Moreover, it's important to note that the provider group average as a basis for shrinkage is one of several possible choices that could be employed in practice and deserves further exploration in future research. With these caveats, our results demonstrate that incorporating reliability adjustment into physician performance measurements is feasible and can notably reduce the incidence of "real" signals relative to what one would expect to see using more traditional approaches. A physician leader who is interested in catalyzing performance improvement

  16. Raising Reliability of Web Search Tool Research through Replication and Chaos Theory

    OpenAIRE

    Nicholson, Scott

    1999-01-01

    Because the World Wide Web is a dynamic collection of information, the Web search tools (or "search engines") that index the Web are dynamic. Traditional information retrieval evaluation techniques may not provide reliable results when applied to the Web search tools. This study is the result of ten replications of the classic 1996 Ding and Marchionini Web search tool research. It explores the effects that replication can have on transforming unreliable results from one iteration into replica...

  17. Reliability of Using Motion Sensors to Measure Children’s Physical Activity Levels in Exergaming

    Directory of Open Access Journals (Sweden)

    Nan Zeng

    2018-05-01

    Full Text Available Objectives: This study examined the reliability of two objective measurement tools in assessing children’s physical activity (PA levels in an exergaming setting. Methods: A total of 377 children (190 girls, Mage = 8.39, SD = 1.55 attended the 30-min exergaming class every other day for 18 weeks. Children’s PA levels were concurrently measured by NL-1000 pedometer and ActiGraph GT3X accelerometer, while children’s steps per min and time engaged in sedentary, light, and moderate-to-vigorous PA were estimated, respectively. Results: The results of intraclass correlation coefficient (ICC indicated a low degree of reliability (single measures ICC = 0.03 in accelerometers. ANOVA did detect a possible learning effect for 27 classes (p < 0.01, and the single measures ICC was 0.20 for pedometers. Moreover, there was no significant positive relationship between steps per min and time spent in moderate-to-vigorous physical activity (MVPA. Finally, only 1.3% variance was explained by pedometer as a predictor using Hierarchical Linear Modeling to further explore the relationship between pedometer and accelerometer data. Conclusions: The NL-1000 pedometers and ActiGraph GT3X accelerometers have low reliability in assessing elementary school children’s PA levels during exergaming. More research is warranted in determining the reliable and accurate measurement information regarding the use of modern devices in exergaming setting.

  18. Factor Structure, Reliability and Measurement Invariance of the Alberta Context Tool and the Conceptual Research Utilization Scale, for German Residential Long Term Care

    Science.gov (United States)

    Hoben, Matthias; Estabrooks, Carole A.; Squires, Janet E.; Behrens, Johann

    2016-01-01

    We translated the Canadian residential long term care versions of the Alberta Context Tool (ACT) and the Conceptual Research Utilization (CRU) Scale into German, to study the association between organizational context factors and research utilization in German nursing homes. The rigorous translation process was based on best practice guidelines for tool translation, and we previously published methods and results of this process in two papers. Both instruments are self-report questionnaires used with care providers working in nursing homes. The aim of this study was to assess the factor structure, reliability, and measurement invariance (MI) between care provider groups responding to these instruments. In a stratified random sample of 38 nursing homes in one German region (Metropolregion Rhein-Neckar), we collected questionnaires from 273 care aides, 196 regulated nurses, 152 allied health providers, 6 quality improvement specialists, 129 clinical leaders, and 65 nursing students. The factor structure was assessed using confirmatory factor models. The first model included all 10 ACT concepts. We also decided a priori to run two separate models for the scale-based and the count-based ACT concepts as suggested by the instrument developers. The fourth model included the five CRU Scale items. Reliability scores were calculated based on the parameters of the best-fitting factor models. Multiple-group confirmatory factor models were used to assess MI between provider groups. Rather than the hypothesized ten-factor structure of the ACT, confirmatory factor models suggested 13 factors. The one-factor solution of the CRU Scale was confirmed. The reliability was acceptable (>0.7 in the entire sample and in all provider groups) for 10 of 13 ACT concepts, and high (0.90–0.96) for the CRU Scale. We could demonstrate partial strong MI for both ACT models and partial strict MI for the CRU Scale. Our results suggest that the scores of the German ACT and the CRU Scale for nursing

  19. Reliability and validity of the Performance Recorder 1 for measuring isometric knee flexor and extensor strength.

    Science.gov (United States)

    Neil, Sarah E; Myring, Alec; Peeters, Mon Jef; Pirie, Ian; Jacobs, Rachel; Hunt, Michael A; Garland, S Jayne; Campbell, Kristin L

    2013-11-01

    Muscular strength is a key parameter of rehabilitation programs and a strong predictor of functional capacity. Traditional methods to measure strength, such as manual muscle testing (MMT) and hand-held dynamometry (HHD), are limited by the strength and experience of the tester. The Performance Recorder 1 (PR1) is a strength assessment tool attached to resistance training equipment and may be a time- and cost-effective tool to measure strength in clinical practice that overcomes some limitations of MMT and HHD. However, reliability and validity of the PR1 have not been reported. Test-retest and inter-rater reliability was assessed using the PR1 in healthy adults (n  =  15) during isometric knee flexion and extension. Criterion-related validity was assessed through comparison of values obtained from the PR1 and Biodex® isokinetic dynamometer. Test-retest reliability was excellent for peak knee flexion (intra-class correlation coefficient [ICC] of 0.96, 95% CI: 0.85, 0.99) and knee extension (ICC  =  0.96, 95% CI: 0.87, 0.99). Inter-rater reliability was also excellent for peak knee flexion (ICC  =  0.95, 95% CI: 0.85, 0.99) and peak knee extension (ICC  =  0.97, 95% CI: 0.91, 0.99). Validity was moderate for peak knee flexion (ICC  =  0.75, 95% CI: 0.38, 0.92) but poor for peak knee extension (ICC  =  0.37, 95% CI: 0, 0.73). The PR1 provides a reliable measure of isometric knee flexor and extensor strength in healthy adults that could be used in the clinical setting, but absolute values may not be comparable to strength assessment by gold-standard measures.

  20. Reliability and validity of a tool to assess airway management skills in anesthesia trainees

    Directory of Open Access Journals (Sweden)

    Aliya Ahmed

    2016-01-01

    Conclusion: The tool designed to assess bag-mask ventilation and tracheal intubation skills in anesthesia trainees demonstrated excellent inter-rater reliability, fair test-retest reliability, and good construct validity. The authors recommend its use for formative and summative assessment of junior anesthesia trainees.

  1. Developing the School Physical Activity and Nutrition Environment Tool to Measure Qualities of the Obesogenic Context

    Science.gov (United States)

    John, Deborah H.; Gunter, Katherine; Jackson, Jennifer A.; Manore, Melinda

    2016-01-01

    Background: Practical tools are needed that reliably measure the complex physical activity (PA) and nutrition environments of elementary schools that influence children's health and learning behaviors for obesity prevention. The School Physical Activity and Nutrition-Environment Tool (SPAN-ET) was developed and beta tested in 6 rural Oregon…

  2. The Takei Handheld Dynamometer: An Effective Clinical Outcome Measure Tool for Hand and Wrist Function in Boxing.

    Science.gov (United States)

    Gatt, Ian; Smith-Moore, Sophie; Steggles, Charlie; Loosemore, Mike

    2018-05-01

    The aim of this article was to explore retrospectively the Takei dynamometer as a valid and reliable outcome measure tool for hand and wrist pathology in the Great Britain amateur boxing squad between 2010 and 2014. Longitudinal retrospective injury surveillance of the Great Britain boxing squad was performed from 2010 to 2014. The location, region affected, description, and duration of each injury were recorded by the team doctor and team physiotherapists. For each significant injury, we recorded hand grip scores using the Takei handheld dynamometer and compared the scores with baseline measures. At the hand, fractures and dislocations were highly detected with an average difference of 40.2% ( P 20% should be highly considered for significant pathology. The Takei dynamometer is a valid and reliable outcome measure tool for hand and wrist pathologies in boxing. Our study highlights the importance of appropriate clinical tools to guide injury management in this sport.

  3. Reliability and validity of the Pragmatics Observational Measure (POM): a new observational measure of pragmatic language for children.

    Science.gov (United States)

    Cordier, Reinie; Munro, Natalie; Wilkes-Gillan, Sarah; Speyer, Renée; Pearce, Wendy M

    2014-07-01

    There is a need for a reliable and valid assessment of childhood pragmatic language skills during peer-peer interactions. This study aimed to evaluate the psychometric properties of a newly developed pragmatic assessment, the Pragmatic Observational Measure (POM). The psychometric properties of the POM were investigated from observational data of two studies - study 1 involved 342 children aged 5-11 years (108 children with ADHD; 108 typically developing playmates; 126 children in the control group), and study 2 involved 9 children with ADHD who attended a 7-week play-based intervention. The psychometric properties of the POM were determined based on the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) taxonomy of psychometric properties and definitions for health-related outcomes; the Pragmatic Protocol was used as the reference tool against which the POM was evaluated. The POM demonstrated sound psychometric properties in all the reliability, validity and interpretability criteria against which it was assessed. The findings showed that the POM is a reliable and valid measure of pragmatic language skills of children with ADHD between the age of 5 and 11 years and has clinical utility in identifying children with pragmatic language difficulty. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Risk Management and Viability of Public Organizations. Development of a Risk Measurement Tool: The Case of Greece

    Directory of Open Access Journals (Sweden)

    Iordanis Eleftheriadis

    2017-03-01

    Full Text Available Purpose: This paper provides an important contribution towards the development of a valid, reliable and cost-effective instrument that reduces operational and economic risk levels in public sector organizations. Design/methodology/approach: A quantitative methodology based on the collection of primary data via a questionnaire has been adopted in this research. Findings: The research results showed that the measurement tool selected, applied, presented and proposed is comprised of three (3 scales. The reliability analysis proved that all three scales are reliable; therefore, they are suitable for use as a risk measurement instrument. Research limitations/implications: The study's academic contribution is the application and testing of the aforementioned measurement instruments, which can now be utilised by researchers in the field of risk management, to further advance the study of risk management in public organizations in Greece. On the empirical level, the implementation of these three measurement instruments can assist public organizations in Greece via an easy and fast assessment of economic and operational risks. Originality/value: This tool can help public organizations gain insight into the level of risk they face at any given point in time in order plan their actions accordingly. At the same time, central state administration will have the necessary tools to monitor and support the organizations it evaluates.

  5. Validity and reliability of a new tool to evaluate handwriting difficulties in Parkinson's disease.

    Directory of Open Access Journals (Sweden)

    Evelien Nackaerts

    Full Text Available Handwriting in Parkinson's disease (PD features specific abnormalities which are difficult to assess in clinical practice since no specific tool for evaluation of spontaneous movement is currently available.This study aims to validate the 'Systematic Screening of Handwriting Difficulties' (SOS-test in patients with PD.Handwriting performance of 87 patients and 26 healthy age-matched controls was examined using the SOS-test. Sixty-seven patients were tested a second time within a period of one month. Participants were asked to copy as much as possible of a text within 5 minutes with the instruction to write as neatly and quickly as in daily life. Writing speed (letters in 5 minutes, size (mm and quality of handwriting were compared. Correlation analysis was performed between SOS outcomes and other fine motor skill measurements and disease characteristics. Intrarater, interrater and test-retest reliability were assessed using the intraclass correlation coefficient (ICC and Spearman correlation coefficient.Patients with PD had a smaller (p = 0.043 and slower (p 0.769 for both groups.The SOS-test is a short and effective tool to detect handwriting problems in PD with excellent reliability. It can therefore be recommended as a clinical instrument for standardized screening of handwriting deficits in PD.

  6. Assessing functional mobility in survivors of lower-extremity sarcoma: reliability and validity of a new assessment tool.

    Science.gov (United States)

    Marchese, Victoria G; Rai, Shesh N; Carlson, Claire A; Hinds, Pamela S; Spearing, Elena M; Zhang, Lijun; Callaway, Lulie; Neel, Michael D; Rao, Bhaskar N; Ginsberg, Jill P

    2007-08-01

    Reliability and validity of a new tool, Functional Mobility Assessment (FMA), were examined in patients with lower-extremity sarcoma. FMA requires the patients to physically perform the functional mobility measures, unlike patient self-report or clinician administered measures. A sample of 114 subjects participated, 20 healthy volunteers and 94 patients with lower-extremity sarcoma after amputation, limb-sparing, or rotationplasty surgery. Reliability of the FMA was examined by three raters testing 20 healthy volunteers and 23 subjects with lower-extremity sarcoma. Concurrent validity was examined using data from 94 subjects with lower-extremity sarcoma who completed the FMA, Musculoskeletal Tumor Society (MSTS), Short-Form 36 (SF-36v2), and Toronto Extremity Salvage Scale (TESS) scores. Construct validity was measured by the ability of the FMA to discriminate between subjects with and without functional mobility deficits. FMA demonstrated excellent reliability (ICC [2,1] >or=0.97). Moderate correlations were found between FMA and SF-36v2 (r = 0.60, P < 0.01), FMA and MSTS (r = 0.68, P < 0.01), and FMA and TESS (r = 0.62, P < 0.01). The patients with lower-extremity sarcoma scored lower on the FMA as compared to healthy controls (P < 0.01). The FMA is a reliable and valid functional outcome measure for patients with lower-extremity sarcoma. This study supports the ability of the FMA to discriminate between patients with varying functional abilities and supports the need to include measures of objective functional mobility in examination of patients with lower-extremity sarcoma.

  7. Reliability Oriented Design Tool For the New Generation of Grid Connected PV-Inverters

    DEFF Research Database (Denmark)

    Sintamarean, Nicolae Cristian; Blaabjerg, Frede; Wang, Huai

    2015-01-01

    is achieved and is further used as an input to the lifetime model. The proposed reliability-oriented design tool is used to study the impact of mission profile (MP) variation and device degradation (aging) in the PV inverter lifetime. The obtained results indicate that the MP of the field where the PV...... inverter is operating has an important impact (up to 70%) on the converter lifetime expectation, and it should be considered in the design stage to better optimize the converter design margin. In order to have correct lifetime estimation, it is crucial to consider also the device degradation feedback (in......This paper introduces a reliability-oriented design tool for a new generation of grid-connected photovoltaic (PV) inverters. The proposed design tool consists of a real field mission profile (RFMP) model (for two operating regions: USA and Denmark), a PV panel model, a grid-connected PV inverter...

  8. Limits of reliability for the measurement of integral count

    International Nuclear Information System (INIS)

    Erbeszkorn, L.

    1979-01-01

    A method is presented for exact and approximate calculation of reliability limits of measured nuclear integral count. The formulae are applicable in measuring conditions which assure the Poisson distribution of the counts. The coefficients of the approximate formulae for 90, 95, 98 and 99 per cent reliability levels are given. The exact reliability limits for 90 per cent reliability level are calculated up to 80 integral counts. (R.J.)

  9. Reliability of four experimental mechanical pain tests in children

    DEFF Research Database (Denmark)

    Søe, Ann-Britt Langager; Thomsen, Lise L; Tornoe, Birte

    2013-01-01

    In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT) in healthy children. Furthermore, the aim was a...... was also to study the intersession reliability of the following four tests: (1) Total Tenderness Score; (2) PPT; (3) Visual Analog Scale score at suprapressure pain threshold; and (4) area under the curve (stimulus-response functions for pressure versus pain).......In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT) in healthy children. Furthermore, the aim...

  10. Measures of differences in reliability

    International Nuclear Information System (INIS)

    Doksum, K.A.

    1975-01-01

    Measures of differences in reliability of two systems are considered in the scale model, location-scale model, and a nonparametric model. In each model, estimates and confidence intervals are given and some of their properties discussed

  11. The role of quality tools in assessing reliability of the internet for health information.

    Science.gov (United States)

    Hanif, Faisal; Read, Janet C; Goodacre, John A; Chaudhry, Afzal; Gibbs, Paul

    2009-12-01

    The Internet has made it possible for patients and their families to access vast quantities of information that previously would have been difficult for anyone but a physician or librarian to obtain. Health information websites, however, are recognised to differ widely in quality and reliability of their content. This has led to the development of various codes of conduct or quality rating tools to assess the quality of health websites. However, the validity and reliability of these quality tools and their applicability to different health websites also varies. In principle, rating tools should be available to consumers, require a limited number of elements to be assessed, be assessable in all elements, be readable and be able to gauge the readability and consistency of information provided from a patient's view point. This article reviews the literature on the trends of the Internet use for health and analyses various codes of conduct/ethics or 'quality tools' available to monitor the quality of health websites from a patient perspective.

  12. Use of reliability engineering tools in safety and risk assessment of nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Raso, Amanda Laureano; Vasconcelos, Vanderley de; Marques, Raíssa Oliveira; Soares, Wellington Antonio; Mesquita, Amir Zacarias, E-mail: amandaraso@hotmail.com, E-mail: vasconv@cdtn.br, E-mail: raissaomarques@gmail.com, E-mail: soaresw@cdtn.br, E-mail: amir@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Serviço de Tecnologia de Reatores

    2017-07-01

    Safety, reliability and availability are fundamental criteria in design, construction and operation of nuclear facilities, as nuclear power plants. Deterministic and probabilistic risk assessments of such facilities are required by regulatory authorities in order to meet licensing regulations, contributing to assure safety, as well as reduce costs and environmental impacts. Probabilistic Risk Assessment has become an important part of licensing requirements of the nuclear power plants in Brazil and in the world. Risk can be defined as a qualitative and/or quantitative assessment of accident sequence frequencies (or probabilities) and their consequences. Risk management is a systematic application of management policies, procedures and practices to identify, analyze, plan, implement, control, communicate and document risks. Several tools and computer codes must be combined, in order to estimate both probabilities and consequences of accidents. Event Tree Analysis (ETA), Fault Tree Analysis (FTA), Reliability Block Diagrams (RBD), and Markov models are examples of evaluation tools that can support the safety and risk assessment for analyzing process systems, identifying potential accidents, and estimating consequences. Because of complexity of such analyzes, specialized computer codes are required, such as the reliability engineering software develop by Reliasoft® Corporation. BlockSim (FTA, RBD and Markov models), RENO (ETA and consequence assessment), Weibull++ (life data and uncertainty analysis), and Xfmea (qualitative risk assessment) are some codes that can be highlighted. This work describes an integrated approach using these tools and software to carry out reliability, safety, and risk assessment of nuclear facilities, as well as, and application example. (author)

  13. Use of reliability engineering tools in safety and risk assessment of nuclear facilities

    International Nuclear Information System (INIS)

    Raso, Amanda Laureano; Vasconcelos, Vanderley de; Marques, Raíssa Oliveira; Soares, Wellington Antonio; Mesquita, Amir Zacarias

    2017-01-01

    Safety, reliability and availability are fundamental criteria in design, construction and operation of nuclear facilities, as nuclear power plants. Deterministic and probabilistic risk assessments of such facilities are required by regulatory authorities in order to meet licensing regulations, contributing to assure safety, as well as reduce costs and environmental impacts. Probabilistic Risk Assessment has become an important part of licensing requirements of the nuclear power plants in Brazil and in the world. Risk can be defined as a qualitative and/or quantitative assessment of accident sequence frequencies (or probabilities) and their consequences. Risk management is a systematic application of management policies, procedures and practices to identify, analyze, plan, implement, control, communicate and document risks. Several tools and computer codes must be combined, in order to estimate both probabilities and consequences of accidents. Event Tree Analysis (ETA), Fault Tree Analysis (FTA), Reliability Block Diagrams (RBD), and Markov models are examples of evaluation tools that can support the safety and risk assessment for analyzing process systems, identifying potential accidents, and estimating consequences. Because of complexity of such analyzes, specialized computer codes are required, such as the reliability engineering software develop by Reliasoft® Corporation. BlockSim (FTA, RBD and Markov models), RENO (ETA and consequence assessment), Weibull++ (life data and uncertainty analysis), and Xfmea (qualitative risk assessment) are some codes that can be highlighted. This work describes an integrated approach using these tools and software to carry out reliability, safety, and risk assessment of nuclear facilities, as well as, and application example. (author)

  14. 3D photography is a reliable burn wound area assessment tool compared to digital planimetry in very young children.

    Science.gov (United States)

    Gee Kee, E L; Kimble, R M; Stockton, K A

    2015-09-01

    Reliability and validity of 3D photography (3D LifeViz™ System) compared to digital planimetry (Visitrak™) has been established in a compliant cohort of children with acute burns. Further research is required to investigate these assessment tools in children representative of the general pediatric burns population, specifically children under the age of three years. To determine if 3D photography is a reliable wound assessment tool compared to Visitrak™ in children of all ages with acute burns ≤10% TBSA. Ninety-six children (median age 1 year 9 months) who presented to the Royal Children's Hospital Brisbane with an acute burn ≤10% TBSA were recruited into the study. Wounds were measured at the first dressing change using the Visitrak™ system and 3D photography. All measurements were completed by one investigator and level of agreement between wound surface area measurements was calculated. Wound surface area measurements were complete (i.e. participants had measurements from both techniques) for 75 participants. Level of agreement between wound surface area measurements calculated using an intra-class correlation coefficient (ICC) was excellent (ICC 0.96, 95% CI 0.93, 0.97). Visitrak™ tracings could not be completed in 19 participants with 16 aged less than two years. 3D photography could not be completed for one participant. Barriers to completing tracings were: excessive movement, pain, young age or wound location (e.g. face or perineum). This study has confirmed 3D photography as a reliable alternative to digital planimetry in children of all ages with acute burns ≤10% TBSA. In addition, 3D photography is more suitable for very young children given its non-invasive nature. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  15. MEASURING SPORT-SPECIFIC PHYSICAL ABILITIES IN MALE GYMNASTS: THE MEN'S GYMNASTICS FUNCTIONAL MEASUREMENT TOOL

    Science.gov (United States)

    Kenyon, Lisa K.; Elliott, James M; Cheng, M. Samuel

    2016-01-01

    Purpose/Background Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. Methods A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts’ USA-Gymnastics competitive level to calculate the coefficient of determination (r2). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. Results The relationship between total MGFMT scores and subjects’ current USA-Gymnastics competitive level was found to be good (r2 = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). Conclusions The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level of Evidence Level 3 PMID:27999723

  16. Reliability, precision, and measurement in the context of data from ability tests, surveys, and assessments

    International Nuclear Information System (INIS)

    Fisher, W P Jr; Elbaum, B; Coulter, A

    2010-01-01

    Reliability coefficients indicate the proportion of total variance attributable to differences among measures separated along a quantitative continuum by a testing, survey, or assessment instrument. Reliability is usually considered to be influenced by both the internal consistency of a data set and the number of items, though textbooks and research papers rarely evaluate the extent to which these factors independently affect the data in question. Probabilistic formulations of the requirements for unidimensional measurement separate consistency from error by modelling individual response processes instead of group-level variation. The utility of this separation is illustrated via analyses of small sets of simulated data, and of subsets of data from a 78-item survey of over 2,500 parents of children with disabilities. Measurement reliability ultimately concerns the structural invariance specified in models requiring sufficient statistics, parameter separation, unidimensionality, and other qualities that historically have made quantification simple, practical, and convenient for end users. The paper concludes with suggestions for a research program aimed at focusing measurement research more on the calibration and wide dissemination of tools applicable to individuals, and less on the statistical study of inter-variable relations in large data sets.

  17. Test-Retest Reliability of Isokinetic Knee Strength Measurements in Children Aged 8 to 10 Years.

    Science.gov (United States)

    Fagher, Kristina; Fritzson, Annelie; Drake, Anna Maria

    Isokinetic dynamometry is a useful tool to objectively assess muscle strength of children and adults in athletic and rehabilitative settings. This study examined test-retest reliability of isokinetic knee strength measurements in children aged 8 to 10 years and defined limits for the minimum difference (MD) in strength that indicates a clinically important change. Isokinetic knee strength measurements (using the Biodex System 4) in children will provide reliable results. Descriptive laboratory study. In 22 healthy children, 5 maximal concentric (CON) knee extensor (KE) and knee flexor (KF) contractions at 2 angular velocities (60 deg/s and 180 deg/s) and 5 maximal eccentric (ECC) KE/KF contractions at 60 deg/s were assessed 7 days apart. The intraclass correlation coefficient (ICC 2.1 ) was used to examine relative reliability, and the MD was calculated on the basis of standard error of measurement. ICCs for CON KE/KF peak torque measurements were fair to excellent (range, 0.49-0.81). The MD% values for CON KE and KF ranged from 31% to 37% at 60 deg/s and from 34% to 39% at 180 deg/s. ICCs in the ECC mode were good (range, 0.60-0.70), but associated MD% values were high (>50%). There was no systematic error for CON KE/KF and ECC KE strength measurements at 60 deg/s, but systematic error was found for all other measurements. The dynamometer provides a reliable analysis of isokinetic CON knee strength measurements at 60 deg/s in children aged 8 to 10 years. Measurements at 180 deg/s and in the ECC mode were not reliable, indicating a need for more familiarization prior to testing. The MD values may help clinicians to determine whether a change in knee strength is due to error or intervention.

  18. How to Measure the Onset of Babbling Reliably?

    Science.gov (United States)

    Molemans, Inge; van den Berg, Renate; van Severen, Lieve; Gillis, Steven

    2012-01-01

    Various measures for identifying the onset of babbling have been proposed in the literature, but a formal definition of the exact procedure and a thorough validation of the sample size required for reliably establishing babbling onset is lacking. In this paper the reliability of five commonly used measures is assessed using a large longitudinal…

  19. Toward a Common Language for Measuring Patient Mobility in the Hospital: Reliability and Construct Validity of Interprofessional Mobility Measures.

    Science.gov (United States)

    Hoyer, Erik H; Young, Daniel L; Klein, Lisa M; Kreif, Julie; Shumock, Kara; Hiser, Stephanie; Friedman, Michael; Lavezza, Annette; Jette, Alan; Chan, Kitty S; Needham, Dale M

    2018-02-01

    The lack of common language among interprofessional inpatient clinical teams is an important barrier to achieving inpatient mobilization. In The Johns Hopkins Hospital, the Activity Measure for Post-Acute Care (AM-PAC) Inpatient Mobility Short Form (IMSF), also called "6-Clicks," and the Johns Hopkins Highest Level of Mobility (JH-HLM) are part of routine clinical practice. The measurement characteristics of these tools when used by both nurses and physical therapists for interprofessional communication or assessment are unknown. The purposes of this study were to evaluate the reliability and minimal detectable change of AM-PAC IMSF and JH-HLM when completed by nurses and physical therapists and to evaluate the construct validity of both measures when used by nurses. A prospective evaluation of a convenience sample was used. The test-retest reliability and the interrater reliability of AM-PAC IMSF and JH-HLM for inpatients in the neuroscience department (n = 118) of an academic medical center were evaluated. Each participant was independently scored twice by a team of 2 nurses and 1 physical therapist; a total of 4 physical therapists and 8 nurses participated in reliability testing. In a separate inpatient study protocol (n = 69), construct validity was evaluated via an assessment of convergent validity with other measures of function (grip strength, Katz Activities of Daily Living Scale, 2-minute walk test, 5-times sit-to-stand test) used by 5 nurses. The test-retest reliability values (intraclass correlation coefficients) for physical therapists and nurses were 0.91 and 0.97, respectively, for AM-PAC IMSF and 0.94 and 0.95, respectively, for JH-HLM. The interrater reliability values (intraclass correlation coefficients) between physical therapists and nurses were 0.96 for AM-PAC IMSF and 0.99 for JH-HLM. Construct validity (Spearman correlations) ranged from 0.25 between JH-HLM and right-hand grip strength to 0.80 between AM-PAC IMSF and the Katz Activities of

  20. The Reliability of Anthropometric Measurements Used Preoperatively in Aesthetic Breast Surgery.

    Science.gov (United States)

    Isaac, Kathryn V; Murphy, Blake D; Beber, Brett; Brown, Mitchell

    2016-04-01

    Patient outcomes in aesthetic breast surgery are highly dependent on breast measurements used in preoperative planning. The purpose of this study is to determine the reliability of anthropometric breast measurements. Four raters measured 28 women using 7 measurements: sternal notch to nipple distance (Sn-N), nipple to midline (N-M), nipple to inframammary-fold distance under maximal stretch (N-IMF), breast base width (BW), soft tissue pinch thickness of the upper pole (STPT:UP), STPT at the inframammary fold (STPT:IMF), and anterior pull skin stretch (APSS). Reliability was assessed using intra-class correlation coefficients (ICCs). Inter-rater reliability was excellent for Sn-N, N-M, and BW (ICC = 0.94, 0.90, and 0.76, respectively) and was good for N-IMF (ICC = 0.70). The STPT:UP, STPT:IMF, and APSS measurements were not reliable between raters (ICC reliability was excellent for Sn-N, N-M, and BW for all raters (all ICC > 0.75). The N-IMF intra-rater reliability was excellent in senior raters (ICC > 0.75) and good in junior raters (ICC > 0.6). The STPT:UP, STPT:IMF, and APSS measurements showed fair or poor reliability for most raters (ICC reliable. Dynamic measurements including APSS, STPT:UP, and STUP:IMF are unreliable. N-IMF is the only reliable dynamic measurement, and its reliability improves with increasing clinical experience. The variable reliability of preoperative measurements must be considered in the planning of aesthetic breast surgery. 4 Diagnostic. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  1. Reliability Centered Maintenance - Methodologies

    Science.gov (United States)

    Kammerer, Catherine C.

    2009-01-01

    Journal article about Reliability Centered Maintenance (RCM) methodologies used by United Space Alliance, LLC (USA) in support of the Space Shuttle Program at Kennedy Space Center. The USA Reliability Centered Maintenance program differs from traditional RCM programs because various methodologies are utilized to take advantage of their respective strengths for each application. Based on operational experience, USA has customized the traditional RCM methodology into a streamlined lean logic path and has implemented the use of statistical tools to drive the process. USA RCM has integrated many of the L6S tools into both RCM methodologies. The tools utilized in the Measure, Analyze, and Improve phases of a Lean Six Sigma project lend themselves to application in the RCM process. All USA RCM methodologies meet the requirements defined in SAE JA 1011, Evaluation Criteria for Reliability-Centered Maintenance (RCM) Processes. The proposed article explores these methodologies.

  2. Extented second moment algebra as an efficient tool in structural reliability

    International Nuclear Information System (INIS)

    Ditlevsen, O.

    1982-01-01

    During the seventies, second moment structural reliability analysis was extensively discussed with respect to philosophy and method. One recent clarification into a consistent formalism is represented by the extended second moment reliability theory with the generalized reliability index as its measure of safety. Its methods of formal failure probability calculations are useful independent of the opinion that one may adopt about the philosophy of the second moment reliability formalism. After an introduction of the historical development of the philosphy the paper gives a short introductory review of the extended second moment structural reliability theory. (orig.)

  3. Criteria and tools for scientific software quality measurements

    Energy Technology Data Exchange (ETDEWEB)

    Tseng, M Y [Previse Inc., Willowdale ON (Canada)

    1995-12-01

    Not all software used in the nuclear industry needs the rigorous formal verification, reliability testing and quality assessment that are being applied to safety critical software. Recently, however, there is increasing recognition that systematic and objective quality assessment of the scientific software used in design and safety analyses of nuclear facilities is necessary to support safety and licensing decisions. Because of the complexity and large size of these programs and the resource constraints faced by the AECB reviewer, it is desirable that appropriate automated tools are used wherever practical. To objectively assess the quality of software, a set of attributes of a software product by which its quality is described and evaluated must be established. These attributes must be relevant to the application domain of software under evaluation. To effectively assess the quality of software, metrics defining quantitative scale and method appropriate to determine the value of attributes need to be applied. To cost-effectively perform the evaluation, use of suitable automated tools is desirable. In this project, criteria for evaluating the quality of scientific software are presented; metrics for which those criteria can be evaluated are identified; a survey of automated tools to measure those metrics was conducted and the most appropriate tool (QA Fortran) was acquired; and the tool usage was demonstrated on three sample programs. (author) 5 refs.

  4. Criteria and tools for scientific software quality measurements

    International Nuclear Information System (INIS)

    Tseng, M.Y.

    1995-12-01

    Not all software used in the nuclear industry needs the rigorous formal verification, reliability testing and quality assessment that are being applied to safety critical software. Recently, however, there is increasing recognition that systematic and objective quality assessment of the scientific software used in design and safety analyses of nuclear facilities is necessary to support safety and licensing decisions. Because of the complexity and large size of these programs and the resource constraints faced by the AECB reviewer, it is desirable that appropriate automated tools are used wherever practical. To objectively assess the quality of software, a set of attributes of a software product by which its quality is described and evaluated must be established. These attributes must be relevant to the application domain of software under evaluation. To effectively assess the quality of software, metrics defining quantitative scale and method appropriate to determine the value of attributes need to be applied. To cost-effectively perform the evaluation, use of suitable automated tools is desirable. In this project, criteria for evaluating the quality of scientific software are presented; metrics for which those criteria can be evaluated are identified; a survey of automated tools to measure those metrics was conducted and the most appropriate tool (QA Fortran) was acquired; and the tool usage was demonstrated on three sample programs. (author) 5 refs

  5. ImageJ: A Free, Easy, and Reliable Method to Measure Leg Ulcers Using Digital Pictures.

    Science.gov (United States)

    Aragón-Sánchez, Javier; Quintana-Marrero, Yurena; Aragón-Hernández, Cristina; Hernández-Herero, María José

    2017-12-01

    Wound measurement to document the healing course of chronic leg ulcers has an important role in the management of these patients. Digital cameras in smartphones are readily available and easy to use, and taking pictures of wounds is becoming a routine in specialized departments. Analyzing digital pictures with appropriate software provides clinicians a quick, clean, and easy-to-use tool for measuring wound area. A set of 25 digital pictures of plain foot and leg ulcers was the basis of this study. Photographs were taken placing a ruler next to the wound in parallel with the healthy skin with the iPhone 6S (Apple Inc, Cupertino, CA), which has a camera of 12 megapixels using the flash. The digital photographs were visualized with ImageJ 1.45s freeware (National Institutes of Health, Rockville, MD; http://imagej.net/ImageJ ). Wound area measurement was carried out by 4 raters: head of the department, wound care nurse, physician, and medical student. We assessed intra- and interrater reliability using the interclass correlation coefficient. To determine intraobserver reliability, 2 of the raters repeated the measurement of the set 1 week after the first reading. The interrater model displayed an interclass correlation coefficient of 0.99 with 95% confidence interval of 0.999 to 1.000, showing excellent reliability. The intrarater model of both examiners showed excellent reliability. In conclusion, analyzing digital images of leg ulcers with ImageJ estimates wound area with excellent reliability. This method provides a free, rapid, and accurate way to measure wounds and could routinely be used to document wound healing in daily clinical practice.

  6. Communicative Access Measures for Stroke: Development and Evaluation of a Quality Improvement Tool.

    Science.gov (United States)

    Kagan, Aura; Simmons-Mackie, Nina; Victor, J Charles; Chan, Melodie T

    2017-11-01

    To (1) develop a systems-level quality improvement tool targeting communicative access to information and decision-making for stroke patients with language disorders; and (2) evaluate the resulting tool-the Communicative Access Measures for Stroke (CAMS). Survey development and evaluation was in line with accepted guidelines and included item generation and reduction, survey formatting and composition, pretesting, pilot testing, and reliability assessment. Development and evaluation were carried out in hospital and community agency settings. The project used a convenience sample of 31 participants for the survey development, and 63 participants for the CAMS reliability study (broken down into 6 administrators/managers, 32 frontline staff, 25 participants with aphasia). Eligible participants invited to the reliability study included individuals from 45 community-based organizations in Ontario as well as 4400 individuals from communities of practice. Not applicable. Data were analyzed using kappa statistics and intraclass correlations for each item score on all surveys. A tool, the CAMS, comprising 3 surveys, was developed for health facilities from the perspectives of (1) administrators/policymakers, (2) staff/frontline health care providers, and (3) patients with aphasia (using a communicatively accessible version). Reliability for items on the CAMS-Administrator and CAMS-Staff surveys was moderate to high (kappa/intraclass correlation coefficients [ICCs], .54-1.00). As expected, reliability was lower for the CAMS-Patient survey, with most items having ICCs between 0.4 and 0.6. These findings suggest that CAMS may provide useful quality improvement information for health care facilities with an interest in improving care for patients with stroke and aphasia. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. Test-retest reliability for aerodynamic measures of voice.

    Science.gov (United States)

    Awan, Shaheen N; Novaleski, Carolyn K; Yingling, Julie R

    2013-11-01

    The purpose of this study was to investigate the intrasubject reliability of aerodynamic characteristics of the voice within typical/normal speakers across testing sessions using the Phonatory Aerodynamic System (PAS 6600; KayPENTAX, Montvale, NJ). Participants were 60 healthy young adults (30 males and 30 females) between the ages 18 and 31 years with perceptually typical voice. Participants were tested using the PAS 6600 (Phonatory Aerodynamic System) on two separate days with approximately 1 week between each session at approximately the same time of day. Four PAS protocols were conducted (vital capacity, maximum sustained phonation, comfortable sustained phonation, and voicing efficiency) and measures of expiratory volume, maximum phonation time, mean expiratory airflow (during vowel production) and target airflow (obtained via syllable repetition), peak air pressure, aerodynamic power, aerodynamic resistance, and aerodynamic efficiency were obtained during each testing session. Associated acoustic measures of vocal intensity and frequency were also collected. All phonations were elicited at comfortable pitch and loudness. All aerodynamic and associated variables evaluated in this study showed useable test-retest reliability (ie, intraclass correlation coefficients [ICCs] ≥ 0.60). A high degree of mean test-retest reliability was found across all subjects for aerodynamic and associated acoustic measurements of vital capacity, maximum sustained phonation, glottal resistance, and vocal intensity (all with ICCs > 0.75). Although strong ICCs were observed for measures of glottal power and mean expiratory airflow in males, weaker overall results for these measures (ICC range: 0.60-0.67) were observed in females subjects and sizable coefficients of variation were observed for measures of power, resistance, and efficiency in both men and women. Differences in degree of reliability from measure to measure were revealed in greater detail using methods such as ICCs and

  8. Analytic tools for investigating the structure of network reliability measures with regard to observation correlations

    Science.gov (United States)

    Prószyński, W.; Kwaśniak, M.

    2018-03-01

    A global measure of observation correlations in a network is proposed, together with the auxiliary indices related to non-diagonal elements of the correlation matrix. Based on the above global measure, a specific representation of the correlation matrix is presented, being the result of rigorously proven theorem formulated within the present research. According to the theorem, each positive definite correlation matrix can be expressed by a scale factor and a so-called internal weight matrix. Such a representation made it possible to investigate the structure of the basic reliability measures with regard to observation correlations. Numerical examples carried out for two test networks illustrate the structure of those measures that proved to be dependent on global correlation index. Also, the levels of global correlation are proposed. It is shown that one can readily find an approximate value of the global correlation index, and hence the correlation level, for the expected values of auxiliary indices being the only knowledge about a correlation matrix of interest. The paper is an extended continuation of the previous study of authors that was confined to the elementary case termed uniform correlation. The extension covers arbitrary correlation matrices and a structure of correlation effect.

  9. Reliability of infrared thermometric measurements of skin temperature in the hand.

    Science.gov (United States)

    Packham, Tara L; Fok, Diana; Frederiksen, Karen; Thabane, Lehana; Buckley, Norman

    2012-01-01

    Clinical measurement study. Skin temperature asymmetries (STAs) are used in the diagnosis of complex regional pain syndrome (CRPS), but little evidence exists for reliability of the equipment and methods. This study examined the reliability of an inexpensive infrared (IR) thermometer and measurement points in the hand for the study of STA. ST was measured three times at five points on both hands with an IR thermometer by two raters in 20 volunteers (12 normals and 8 CRPS). ST measurement results using IR thermometers support inter-rater reliability: intraclass correlation coefficient (ICC) estimate for single measures 0.80; all ST measurement points were also highly reliable (ICC single measures, 0.83-0.91). The equipment demonstrated excellent reliability, with little difference in the reliability of the five measurement sites. These preliminary findings support their use in future CRPS research. Not applicable. Copyright © 2012 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  10. The reliability of the Extra Load Index as a measure of relative load carriage economy.

    Science.gov (United States)

    Hudson, Sean; Cooke, Carlton; Lloyd, Ray

    2017-09-01

    The aim of this study was to measure the reliability of the extra load index (ELI) as a method for assessing relative load carriage economy. Seventeen volunteers (12 males, 5 females) performed walking trials at 3 km·h -1 , 6 km·h -1 and a self-selected speed. Trial conditions were repeated 7 days later to assess test-retest reliability. Trials involved four 4-minute periods of walking, each separated by 5 min of rest. The initial stage was performed unloaded followed in a randomised order by a second unloaded period and walking with backpacks of 7 and 20 kg. Results show ELI values did not differ significantly between trials for any of the speeds (p = 0.46) with either of the additional loads (p = 0.297). The systematic bias, limits of agreement and coefficients of variation were small in all trial conditions. We conclude the ELI appears to be a reliable measure of relative load carriage economy. Practitioner Summary: This paper demonstrates that the ELI is a reliable measure of load carriage economy at a range of walking speeds with both a light and heavy load. The ELI, therefore, represents a useful tool for comparing the relative economy associated with different load carriage systems.

  11. Inter- and intrarater reliability of two proprioception tests using clinical applicable measurement tools in subjects with and without knee osteoarthritis.

    Science.gov (United States)

    Baert, Isabel A C; Lluch, Enrique; Struyf, Thomas; Peeters, Greta; Van Oosterwijck, Sophie; Tuynman, Joanna; Rufai, Salim; Struyf, Filip

    2018-06-01

    The therapeutic value of proprioceptive-based exercises in knee osteoarthritis (KOA) management warrants investigation of proprioceptive testing methods easily accessible in clinical practice. To estimate inter- and intrarater reliability of the knee joint position sense (KJPS) test and knee force sense (KFS) test in subjects with and without KOA. Cross-sectional test-retest design. Two blinded raters performed independently repeated measures of the KJPS and KFS test, using an analogue inclinometer and handheld dynamometer, respectively, in eight KOA patients (12 symptomatic knees) and 26 healthy controls (52 asymptomatic knees). Intraclass correlation coefficients (ICCs; model 2,1), standard error of measurement (SEM) and minimal detectable change with 95% confidence bounds (MDC 95 ) were calculated. For KJPS, results showed good to excellent test-retest agreement (ICCs 0.70-0.95 in KOA patients; ICCs 0.65-0.85 in healthy controls). A 2° measurement error (SEM 1°) was reported when measuring KJPS in multiple test positions and calculating mean repositioning error. Testing KOA patients pre and post therapy a repositioning error larger than 4° (MDC 95 ) is needed to consider true change. Measuring KFS using handheld dynamometry showed poor to fair interrater and poor to excellent intrarater reliability in subjects with and without KOA. Measuring KJPS in multiple test positions using an analogue inclinometer and calculating mean repositioning error is reliable and can be used in clinical practice. We do not recommend the use of the KFS test to clinicians. Further research is required to establish diagnostic accuracy and validity of our KJPS test in larger knee pain populations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. The Mental Disability Military Assessment Tool : A Reliable Tool for Determining Disability in Veterans with Post-traumatic Stress Disorder

    NARCIS (Netherlands)

    Fokkens, Andrea S.; Groothoff, Johan W.; van der Klink, Jac J. L.; Popping, Roel; Stewart, Roy E.; van de Ven, Lex; Brouwer, Sandra; Tuinstra, Jolanda

    Purpose An assessment tool was developed to assess disability in veterans who suffer from post-traumatic stress disorder (PTSD) due to a military mission. The objective of this study was to determine the reliability, intra-rater and inter-rater variation of the Mental Disability Military (MDM)

  13. The Mental Disability Military Assessment Tool : A reliable tool for determining disability in veterans with post-traumatic stress disorder

    NARCIS (Netherlands)

    Fokkens, A.S.; Groothoff, J.W.; van der Klink, J.J.L.; Popping, R.; Stewart, S.E.; van de Ven, L.; Brouwer, S.; Tuinstra, J.

    2015-01-01

    Purpose An assessment tool was developed to assess disability in veterans who suffer from post-traumatic stress disorder (PTSD) due to a military mission. The objective of this study was to determine the reliability, intra-rater and inter-rater variation of the Mental Disability Military (MDM)

  14. Developing safety performance functions incorporating reliability-based risk measures.

    Science.gov (United States)

    Ibrahim, Shewkar El-Bassiouni; Sayed, Tarek

    2011-11-01

    Current geometric design guides provide deterministic standards where the safety margin of the design output is generally unknown and there is little knowledge of the safety implications of deviating from these standards. Several studies have advocated probabilistic geometric design where reliability analysis can be used to account for the uncertainty in the design parameters and to provide a risk measure of the implication of deviation from design standards. However, there is currently no link between measures of design reliability and the quantification of safety using collision frequency. The analysis presented in this paper attempts to bridge this gap by incorporating a reliability-based quantitative risk measure such as the probability of non-compliance (P(nc)) in safety performance functions (SPFs). Establishing this link will allow admitting reliability-based design into traditional benefit-cost analysis and should lead to a wider application of the reliability technique in road design. The present application is concerned with the design of horizontal curves, where the limit state function is defined in terms of the available (supply) and stopping (demand) sight distances. A comprehensive collision and geometric design database of two-lane rural highways is used to investigate the effect of the probability of non-compliance on safety. The reliability analysis was carried out using the First Order Reliability Method (FORM). Two Negative Binomial (NB) SPFs were developed to compare models with and without the reliability-based risk measures. It was found that models incorporating the P(nc) provided a better fit to the data set than the traditional (without risk) NB SPFs for total, injury and fatality (I+F) and property damage only (PDO) collisions. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Measuring Passenger Travel Time Reliability using Smartcard Data

    NARCIS (Netherlands)

    Bagherian, M.; Cats, O.; van Oort, N.; Hickman, M

    2016-01-01

    Service reliability is a key performance measure for transit agencies in increasing their service quality and thus ridership. Conventional reliability metrics are established based on vehicle movements and thus do not adequately reflect passenger’s experience. In the past few years, the growing

  16. Reliability importance measures and their calculation

    International Nuclear Information System (INIS)

    Andsten, R.; Vaurio, J.K.

    1989-01-01

    The importance of a component to the system reliability or availability and to the system failure rate can be measured by a number of importance measures. Such measures can be used to guide the system design improvement actions as well as the diagnostic and repair actions. This report develops relationships between several importance measures, illustrates their meaning with interpretations and applications, and describes the computer program called IMPO that calculates importance measures when the system minimum cat sets and component parameters are given. A user's manual is included with illustrative examples

  17. Monte Carlo simulation - a powerful tool to support experimental activities in structure reliability

    International Nuclear Information System (INIS)

    Yuritzinn, T.; Chapuliot, S.; Eid, M.; Masson, R.; Dahl, A.; Moinereau, D.

    2003-01-01

    Monte-Carlo Simulation (MCS) can have different uses in supporting structure reliability investigations and assessments. In this paper we focus our interest on the use of MCS as a numerical tool to support the fitting of the experimental data related to toughness experiments. (authors)

  18. Evidence of Reliability for Persian Version of the “Cumberland Ankle Instability Tool (CAIT” in Iranian Athletes with lateral Ankle Sprain

    Directory of Open Access Journals (Sweden)

    Mitra Haji-Maghsoudi

    2016-01-01

    Full Text Available Objectives: The purpose of the present study was to evaluate the reliability of persian version of the “Cumberland Ankle Instability Tool (CAIT” in Iranian athletes with lateral ankle sprain. Matterials & Methods: The present study is a methodological and non-experimental study. After forward and backward translation of CAIT, 46 athletes were selected with convenient nonprobably sampling from Physical Education Faculty of Tehran university and Taekwondo Club. Questionnaire was given to participants who experienced at least one lateral ankle sprain based on doctor’s diagnosis. In the second phase (one week later the questionnaire was distributed among the participants again to test the reliability of the measured between the two tests. After collecting the data, the test-retest reliability of  Persian version of the questionnaire was evaluated by calculating the intraclass correlation coefficient, standard error of measurement, smallest detectable change and Cronbach’s alpha coefficients were calculated to assess the internal consistency of the questionnaire’s items. Results Cronbach’s alpha was 0.64, which is close to acceptable level of internal consistency (0.7-0.95. Factor analysis showed that questionnaires’ items can be classified  in 4 categories with maximum of 72% variance cover. The test-retest correlation coefficient ICC for the total score of CAIT was 0.95 (P>100.0, indicating excellent reproducibility of the Persian version of the questionnaire. The standard error of measurement (SEM was 1 and the smallest acceptable change (SDC was 2.76 with 95% confidence. Conclusion: The results show that the Persian version of the CAIT can be used in athletes with functional ankle instability as a reliable tool to detect instability and assess changes caused by therapeutic interventions.

  19. Children's Physical Activity While Gardening: Development of a Valid and Reliable Direct Observation Tool.

    Science.gov (United States)

    Myers, Beth M; Wells, Nancy M

    2015-04-01

    Gardens are a promising intervention to promote physical activity (PA) and foster health. However, because of the unique characteristics of gardening, no extant tool can capture PA, postures, and motions that take place in a garden. The Physical Activity Research and Assessment tool for Garden Observation (PARAGON) was developed to assess children's PA levels, tasks, postures, and motions, associations, and interactions while gardening. PARAGON uses momentary time sampling in which a trained observer watches a focal child for 15 seconds and then records behavior for 15 seconds. Sixty-five children (38 girls, 27 boys) at 4 elementary schools in New York State were observed over 8 days. During the observation, children simultaneously wore Actigraph GT3X+ accelerometers. The overall interrater reliability was 88% agreement, and Ebel was .97. Percent agreement values for activity level (93%), garden tasks (93%), motions (80%), associations (95%), and interactions (91%) also met acceptable criteria. Validity was established by previously validated PA codes and by expected convergent validity with accelerometry. PARAGON is a valid and reliable observation tool for assessing children's PA in the context of gardening.

  20. The order progress diagram : A supportive tool for diagnosing delivery reliability performance in make-to-order companies

    NARCIS (Netherlands)

    Soepenberg, G.D.; Land, M.J.; Gaalman, G.J.C.

    This paper describes the development of a new tool for facilitating the diagnosis of logistic improvement opportunities in make-to-order (MTO) companies. Competitiveness of these companies increasingly imposes needs upon delivery reliability. In order to achieve high delivery reliability, both the

  1. Hospital process orientation from an operations management perspective: development of a measurement tool and practical testing in three ophthalmic practices.

    Science.gov (United States)

    Gonçalves, Pedro D; Hagenbeek, Marie Louise; Vissers, Jan M H

    2013-11-13

    Although research interest in hospital process orientation (HPO) is growing, the development of a measurement tool to assess process orientation (PO) has not been very successful yet. To view a hospital as a series of processes organized around patients with a similar demand seems to be an attractive proposition, but it is hard to operationalize this idea in a measurement tool that can actually measure the level of PO. This research contributes to HPO from an operations management (OM) perspective by addressing the alignment, integration and coordination of activities within patient care processes. The objective of this study was to develop and practically test a new measurement tool for assessing the degree of PO within hospitals using existing tools. Through a literature search we identified a number of constructs to measure PO in hospital settings. These constructs were further operationalized, using an OM perspective. Based on five dimensions of an existing questionnaire a new HPO-measurement tool was developed to measure the degree of PO within hospitals on the basis of respondents' perception. The HPO-measurement tool was pre-tested in a non-participating hospital and discussed with experts in a focus group. The multicentre exploratory case study was conducted in the ophthalmic practices of three different types of Dutch hospitals. In total 26 employees from three disciplines participated. After filling in the questionnaire an interview was held with each participant to check the validity and the reliability of the measurement tool. The application of the HPO-measurement tool, analysis of the scores and interviews with the participants resulted in the possibility to identify differences of PO performance and the areas of improvement--from a PO point of view--within each hospital. The result of refinement of the items of the measurement tool after practical testing is a set of 41 items to assess the degree of PO from an OM perspective within hospitals. The

  2. Measuring Outcomes for Dysphagia: Validity and Reliability of the European Portuguese Eating Assessment Tool (P-EAT-10).

    Science.gov (United States)

    Nogueira, Dália Santos; Ferreira, Pedro Lopes; Reis, Elizabeth Azevedo; Lopes, Inês Sousa

    2015-10-01

    The purpose of this study was to evaluate the validity and the reliability of the European Portuguese version of the EAT-10 (P-EAT-10). This research was conducted in three phases: (i) cultural and linguistic adaptation; (ii) feasibility and reliability test; and (iii) validity tests. The final sample was formed by a cohort of 520 subjects. The P-EAT-10 index was compared for socio-demographic and clinic variables. It was also compared for both dysphagic and non-dysphagic groups as well as for the results of the 3Oz wst. Lastly, the P-EAT-10 scores were correlated with the EuroQol Group Portuguese EQ-5D index. The Cronbach's α obtained for the P-EAT-10 scale was 0.952 and it remained excellent even if any item was deleted. The item-total and the intraclass correlation coefficients were very good. The P-EAT-10 mean of the non-dysphagic cohort was 0.56 and that of the dysphagic cohort was 14.26, the mean comparison between the 3Oz wst groups and the P-EAT-10 scores were significant. A significant higher perception of QoL was also found among the non-dysphagic subjects. P-EAT-10 is a valid and reliable measure that may be used to document dysphagia which makes it useful both for screening in clinical practice and in research.

  3. Validation and inter-rater reliability of a three item falls risk screening tool

    Directory of Open Access Journals (Sweden)

    Catherine Maree Said

    2017-11-01

    Full Text Available Abstract Background Falls screening tools are routinely used in hospital settings and the psychometric properties of tools should be examined in the setting in which they are used. The aim of this study was to explore the concurrent and predictive validity of the Austin Health Falls Risk Screening Tool (AHFRST, compared with The Northern Hospital Modified St Thomas’s Risk Assessment Tool (TNH-STRATIFY, and the inter-rater reliability of the AHFRST. Methods A research physiotherapist used the AHFRST and TNH-STRATIFY to classify 130 participants admitted to Austin Health (five acute wards, n = 115 two subacute wards n = 15; median length of stay 6 days IQR 3–12 as ‘High’ or ‘Low’ falls risk. The AHFRST was also completed by nursing staff on patient admission. Falls data was collected from the hospital incident reporting system. Results Six falls occurred during the study period (fall rate of 4.6 falls per 1000 bed days. There was substantial agreement between the AHFRST and the TNH-STRATIFY (Kappa = 0.68, 95% CI 0.52–0.78. Both tools had poor predictive validity, with low specificity (AHFRST 46.0%, 95% CI 37.0–55.1; TNH-STRATIFY 34.7%, 95% CI 26.4–43.7 and positive predictive values (AHFRST 5.6%, 95% CI 1.6–13.8; TNH-STRATIFY 6.9%, 95% CI 2.6–14.4. The AHFRST showed moderate inter-rater reliability (Kappa = 0.54, 95% CI = 0.36–0.67, p < 0.001 although 18 patients did not have the AHFRST completed by nursing staff. Conclusions There was an acceptable level of agreement between the 3 item AHFRST classification of falls risk and the longer, 9 item TNH-STRATIFY classification. However, both tools demonstrated limited predictive validity in the Austin Health population. The results highlight the importance of evaluating the validity of falls screening tools, and the clinical utility of these tools should be reconsidered.

  4. Intrarater and interrater reliability for measurements in videofluoroscopy of swallowing

    International Nuclear Information System (INIS)

    Baijens, Laura; Barikroo, Ali; Pilz, Walmari

    2013-01-01

    Objective: Intrarater and interrater reliability is crucial to the quality of diagnostic and therapy-effect studies. This paper reports on a systematic review of studies on intrarater and interrater reliability for measurements in videofluoroscopy of swallowing. The aim of this review was to summarize and qualitatively analyze published studies on that topic. Materials and methods: Those published up to March 2013 were found through a comprehensive electronic database search using PubMed, Embase, and The Cochrane Library. Two reviewers independently assessed the studies using strict inclusion criteria. Results: Nineteen studies were included and then qualitatively analyzed. In several of these, methodological problems were found. Moreover, intrarater and interrater reliability varied with the measure applied. A meta-analysis was not carried out as studies were not of sufficient quality to warrant doing so. Conclusion: In order to achieve reliable measurements in videofluoroscopy of swallowing, it is recommended that raters use well-defined guidelines for the levels of ordinal visuoperceptual variables. Furthermore, in order to make the measurements reliable (intrarater and interrater) it is recommended that, following protocolled pre-experimental training, the raters should have maximum consensus about the definition of the measured variables

  5. Intrarater and interrater reliability for measurements in videofluoroscopy of swallowing

    Energy Technology Data Exchange (ETDEWEB)

    Baijens, Laura, E-mail: laura.baijens@mumc.nl [Department of Otorhinolaryngology, Head and Neck Surgery, Maastricht University Medical Center, Maastricht (Netherlands); Barikroo, Ali, E-mail: a.Barikroo@ufl.edu [Swallowing Research Laboratory, Department of Speech, Language and Hearing Sciences, College of Public Health and Health Professions, University of Florida, Gainesville, FL (United States); Pilz, Walmari, E-mail: walmari.pilz@mumc.nl [Department of Otorhinolaryngology, Head and Neck Surgery, Maastricht University Medical Center, Maastricht (Netherlands)

    2013-10-01

    Objective: Intrarater and interrater reliability is crucial to the quality of diagnostic and therapy-effect studies. This paper reports on a systematic review of studies on intrarater and interrater reliability for measurements in videofluoroscopy of swallowing. The aim of this review was to summarize and qualitatively analyze published studies on that topic. Materials and methods: Those published up to March 2013 were found through a comprehensive electronic database search using PubMed, Embase, and The Cochrane Library. Two reviewers independently assessed the studies using strict inclusion criteria. Results: Nineteen studies were included and then qualitatively analyzed. In several of these, methodological problems were found. Moreover, intrarater and interrater reliability varied with the measure applied. A meta-analysis was not carried out as studies were not of sufficient quality to warrant doing so. Conclusion: In order to achieve reliable measurements in videofluoroscopy of swallowing, it is recommended that raters use well-defined guidelines for the levels of ordinal visuoperceptual variables. Furthermore, in order to make the measurements reliable (intrarater and interrater) it is recommended that, following protocolled pre-experimental training, the raters should have maximum consensus about the definition of the measured variables.

  6. Development, validity and reliability testing of the East Midlands Evaluation Tool (EMET) for measuring impacts on trainees' confidence and competence following end of life care training.

    Science.gov (United States)

    Whittaker, B; Parry, R; Bird, L; Watson, S; Faull, C

    2017-02-02

    To develop, test and validate a versatile questionnaire, the East Midlands Evaluation Tool (EMET), for measuring effects of end of life care training events on trainees' self-reported confidence and competence. A paper-based questionnaire was designed on the basis of the English Department of Health's core competences for end of life care, with sections for completion pretraining, immediately post-training and also for longer term follow-up. Preliminary versions were field tested at 55 training events delivered by 13 organisations to 1793 trainees working in diverse health and social care backgrounds. Iterative rounds of development aimed to maximise relevance to events and trainees. Internal consistency was assessed by calculating interitem correlations on questionnaire responses during field testing. Content validity was assessed via qualitative content analysis of (1) responses to questionnaires completed by field tester trainers and (2) field notes from a workshop with a separate cohort of experienced trainers. Test-retest reliability was assessed via repeat administration to a cohort of student nurses. The EMET comprises 27 items with Likert-scaled responses supplemented with questions seeking free-text responses. It measures changes in self-assessed confidence and competence on 5 subscales: communication skills; assessment and care planning; symptom management; advance care planning; overarching values and knowledge. Test-retest reliability was found to be good, as was internal consistency: the questions successfully assess different aspects of the same underlying concept. The EMET provides a time-efficient, reliable and flexible means of evaluating effects of training on self-reported confidence and competence in the key elements of end of life care. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Reliability of radiographic measurement of lateral capitellohumeral angle in healthy children.

    Science.gov (United States)

    Hasegawa, Masaki; Suzuki, Taku; Kuroiwa, Takashi; Oka, Yusuke; Maeda, Atsushi; Takeda, Hiroki; Shizu, Kanae; Tsuji, Takashi; Suzuki, Katsuji; Yamada, Harumoto

    2018-04-01

    This retrospective cohort study was designed to validate the reliability of measurement of the lateral capitellohumeral angle (LCHA), an index of sagittal angulation of the elbow, in healthy children. The results were compared to the Baumann angle (BA), which is a similar concept to LCHA.Sixty-two radiographs of the elbow in healthy children (range, 2-11 years) were reviewed by 6 examiners at 2 sessions. The mean value and reliability of the measurement of LCHA and BA were assessed. Intraobserver reliability and interobserver reliability were calculated using intraclass correlation coefficients (ICCs).The mean LCHA value was 45° (range, 22° to 70°) and the mean BA was 71° (range, 56° to 86°). The ICCs for intraobserver reliability of the LCHA measurements were almost perfect for 2 examiners, substantial for 3 examiners, and moderate for 1 examiner with a mean value of 0.77 (range, 0.57-0.95). For BA measurements, the ICCs were almost perfect for 1 examiner and substantial for 5 examiners with a mean value of 0.74 (range, 0.66-0.83). The ICCs for interobserver reliability between the first and second measurements were both moderate for LCHA (0.56 and 0.51) and for BA (0.52 and 0.50).LCHA showed almost the same reliability in measurement as BA, which is the gold standard assessment for coronal alignment of the elbow. LCHA showed moderate-to-good reliability in the evaluation of sagittal plane elbow alignment.

  8. Photogrammetry: an accurate and reliable tool to detect thoracic musculoskeletal abnormalities in preterm infants.

    Science.gov (United States)

    Davidson, Josy; dos Santos, Amelia Miyashiro N; Garcia, Kessey Maria B; Yi, Liu C; João, Priscila C; Miyoshi, Milton H; Goulart, Ana Lucia

    2012-09-01

    To analyse the accuracy and reproducibility of photogrammetry in detecting thoracic abnormalities in infants born prematurely. Cross-sectional study. The Premature Clinic at the Federal University of São Paolo. Fifty-eight infants born prematurely in their first year of life. Measurement of the manubrium/acromion/trapezius angle (degrees) and the deepest thoracic retraction (cm). Digitised photographs were analysed by two blinded physiotherapists using a computer program (SAPO; http://SAPO.incubadora.fapesp.br) to detect shoulder elevation and thoracic retraction. Physical examinations performed independently by two physiotherapists were used to assess the accuracy of the new tool. Thoracic alterations were detected in 39 (67%) and in 40 (69%) infants by Physiotherapists 1 and 2, respectively (kappa coefficient=0.80). Using a receiver operating characteristic curve, measurement of the manubrium/acromion/trapezius angle and the deepest thoracic retraction indicated accuracy of 0.79 and 0.91, respectively. For measurement of the manubrium/acromion/trapezius angle, the Bland and Altman limits of agreement were -6.22 to 7.22° [mean difference (d)=0.5] for repeated measures by one physiotherapist, and -5.29 to 5.79° (d=0.75) between two physiotherapists. For thoracic retraction, the intra-rater limits of agreement were -0.14 to 0.18cm (d=0.02) and the inter-rater limits of agreement were -0.20 to -0.17cm (d=0.02). SAPO provided an accurate and reliable tool for the detection of thoracic abnormalities in preterm infants. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  9. Sliding into happiness: A new tool for measuring affective responses to words

    Science.gov (United States)

    Warriner, Amy Beth; Shore, David I.; Schmidt, Louis A.; Imbault, Constance L.; Kuperman, Victor

    2016-01-01

    Reliable measurement of affective responses is critical for research into human emotion. Affective evaluation of words is most commonly gauged on multiple dimensions—including valence (positivity) and arousal—using a rating scale. Despite its popularity, this scale is open to criticism: it generates ordinal data that is often misinterpreted as interval, it does not provide the fine resolution that is essential by recent theoretical accounts of emotion, and its extremes may not be properly calibrated. In five experiments, we introduce a new slider tool for affective evaluation of words on a continuous, well-calibrated and high-resolution scale. In Experiment 1, participants were shown a word and asked to move a manikin representing themselves closer to or farther away from the word. The manikin’s distance from the word strongly correlated with the word’s valence. In Experiment 2, individual differences in shyness and sociability elicited reliable differences in distance from the words. Experiment 3 validated the results of Experiments 1 and 2 using a demographically more diverse population of responders. Finally, Experiment 4 (along with Experiment 2) suggested that task demand is not a potential cause for scale recalibration. In Experiment 5, men and women placed a manikin closer or farther from words that showed sex differences in valence, highlighting the sensitivity of this measure to group differences. These findings shed a new light on interactions among affect, language, and individual differences, and demonstrate the utility of a new tool for measuring word affect. PMID:28252996

  10. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity

    Directory of Open Access Journals (Sweden)

    Adebisi Bisi-Balogun

    2016-04-01

    Full Text Available This study aimed to determine the relative and absolute reliability of ultrasound (US measurements of the thickness and echogenicity of the plantar fascia (PF at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.

  11. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity.

    Science.gov (United States)

    Bisi-Balogun, Adebisi; Cassel, Michael; Mayer, Frank

    2016-04-13

    This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.

  12. Measuring the quality of Patients’ goals and action plans: development and validation of a novel tool

    Directory of Open Access Journals (Sweden)

    Teal Cayla R

    2012-12-01

    Full Text Available Abstract Background The purpose of this study is to develop and test reliability, validity, and utility of the Goal-Setting Evaluation Tool for Diabetes (GET-D. The effectiveness of diabetes self-management is predicated on goal-setting and action planning strategies. Evaluation of self-management interventions is hampered by the absence of tools to assess quality of goals and action plans. To address this gap, we developed the GET-D, a criteria-based, observer rating scale that measures the quality of patients’ diabetes goals and action plans. Methods We conducted 3-stage development of GET-D, including identification of criteria for observer ratings of goals and action plans, rater training and pilot testing; and then performed psychometric testing of the GET-D. Results Trained raters could effectively rate the quality of patient-generated goals and action plans using the GET-D. Ratings performed by trained evaluators demonstrated good raw agreement (94.4% and inter-rater reliability (Kappa = 0.66. Scores on the GET-D correlated well with measures theoretically associated with goal-setting, including patient activation (r=.252, P Conclusions The GET-D can reliably and validly rate the quality of goals and action plans. It holds promise as a measure of intervention fidelity for clinical interventions that promote diabetes self-management behaviors to improve clinical outcomes. Trial registration Clinicaltrials.gov Identifier: NCT00481286

  13. Effect of standardized training on the reliability of the Cochrane risk of bias assessment tool: a prospective study.

    Science.gov (United States)

    da Costa, Bruno R; Beckett, Brooke; Diaz, Alison; Resta, Nina M; Johnston, Bradley C; Egger, Matthias; Jüni, Peter; Armijo-Olivo, Susan

    2017-03-03

    The Cochrane risk of bias tool is commonly criticized for having a low reliability. We aimed to investigate whether training of raters, with objective and standardized instructions on how to assess risk of bias, can improve the reliability of the Cochrane risk of bias tool. In this pilot study, four raters inexperienced in risk of bias assessment were randomly allocated to minimal or intensive standardized training for risk of bias assessment of randomized trials of physical therapy treatments for patients with knee osteoarthritis pain. Two raters were experienced risk of bias assessors who served as reference. The primary outcome of our study was between-group reliability, defined as the agreement of the risk of bias assessments of inexperienced raters with the reference assessments of experienced raters. Consensus-based assessments were used for this purpose. The secondary outcome was within-group reliability, defined as the agreement of assessments within pairs of inexperienced raters. We calculated the chance-corrected weighted Kappa to quantify agreement within and between groups of raters for each of the domains of the risk of bias tool. A total of 56 trials were included in our analysis. The Kappa for the agreement of inexperienced raters with reference across items of the risk of bias tool ranged from 0.10 to 0.81 for the minimal training group and from 0.41 to 0.90 for the standardized training group. The Kappa values for the agreement within pairs of inexperienced raters across the items of the risk of bias tool ranged from 0 to 0.38 for the minimal training group and from 0.93 to 1 for the standardized training group. Between-group differences in Kappa for the agreement of inexperienced raters with reference always favored the standardized training group and was most pronounced for incomplete outcome data (difference in Kappa 0.52, p training on risk of bias assessment may significantly improve the reliability of the Cochrane risk of bias tool.

  14. Developing a Tool for Measuring the Decision-Making Competence of Older Adults

    Science.gov (United States)

    Finucane, Melissa L.; Gullion, Christina M.

    2010-01-01

    The authors evaluated the reliability and validity of a tool for measuring older adults’ decision-making competence (DMC). Two-hundred-five younger adults (25-45 years), 208 young-older adults (65-74 years), and 198 old-older adults (75-97 years) made judgments and decisions related to health, finance, and nutrition. Reliable indices of comprehension, dimension weighting, and cognitive reflection were developed. Unlike previous research, the authors were able to compare old-older with young-older adults’ performance. As hypothesized, old-older adults performed more poorly than young-older adults; both groups of older adults performed more poorly than younger adults. Hierarchical regression analyses showed that a large amount of variance in decision performance across age groups (including mean trends) could be accounted for by social variables, health measures, basic cognitive skills, attitudinal measures, and numeracy. Structural equation modeling revealed significant pathways from three exogenous latent factors (crystallized intelligence, other cognitive abilities, and age) to the endogenous DMC latent factor. Further research is needed to validate the meaning of performance on these tasks for real-life decision making. PMID:20545413

  15. Response process and test–retest reliability of the Context Assessment for Community Health tool in Vietnam

    Directory of Open Access Journals (Sweden)

    Duong M. Duc

    2016-06-01

    Full Text Available Background: The recently developed Context Assessment for Community Health (COACH tool aims to measure aspects of the local healthcare context perceived to influence knowledge translation in low- and middle-income countries. The tool measures eight dimensions (organizational resources , community engagement, monitoring services for action, sources of knowledge, commitment to work, work culture, leadership, and informal payment through 49 items. Objective: The study aimed to explore the understanding and stability of the COACH tool among health providers in Vietnam. Designs: To investigate the response process, think-aloud interviews were undertaken with five community health workers, six nurses and midwives, and five physicians. Identified problems were classified according to Conrad and Blair's taxonomy and grouped according to an estimation of the magnitude of the problem's effect on the response data. Further, the stability of the tool was examined using a test–retest survey among 77 respondents. The reliability was analyzed for items (intraclass correlation coefficient (ICC and percent agreement and dimensions (ICC and Bland–Altman plots. Results: In general, the think-aloud interviews revealed that the COACH tool was perceived as clear, well organized, and easy to answer. Most items were understood as intended. However, seven prominent problems in the items were identified and the content of three dimensions was perceived to be of a sensitive nature. In the test–retest survey, two-thirds of the items and seven of eight dimensions were found to have an ICC agreement ranging from moderate to substantial (0.5–0.7, demonstrating that the instrument has an acceptable level of stability. Conclusions: This study provides evidence that the Vietnamese translation of the COACH tool is generally perceived to be clear and easy to understand and has acceptable stability. There is, however, a need to rephrase and add generic examples to clarify

  16. Response process and test-retest reliability of the Context Assessment for Community Health tool in Vietnam.

    Science.gov (United States)

    Duc, Duong M; Bergström, Anna; Eriksson, Leif; Selling, Katarina; Thi Thu Ha, Bui; Wallin, Lars

    2016-01-01

    The recently developed Context Assessment for Community Health (COACH) tool aims to measure aspects of the local healthcare context perceived to influence knowledge translation in low- and middle-income countries. The tool measures eight dimensions (organizational resources, community engagement, monitoring services for action, sources of knowledge, commitment to work, work culture, leadership, and informal payment) through 49 items. The study aimed to explore the understanding and stability of the COACH tool among health providers in Vietnam. To investigate the response process, think-aloud interviews were undertaken with five community health workers, six nurses and midwives, and five physicians. Identified problems were classified according to Conrad and Blair's taxonomy and grouped according to an estimation of the magnitude of the problem's effect on the response data. Further, the stability of the tool was examined using a test-retest survey among 77 respondents. The reliability was analyzed for items (intraclass correlation coefficient (ICC) and percent agreement) and dimensions (ICC and Bland-Altman plots). In general, the think-aloud interviews revealed that the COACH tool was perceived as clear, well organized, and easy to answer. Most items were understood as intended. However, seven prominent problems in the items were identified and the content of three dimensions was perceived to be of a sensitive nature. In the test-retest survey, two-thirds of the items and seven of eight dimensions were found to have an ICC agreement ranging from moderate to substantial (0.5-0.7), demonstrating that the instrument has an acceptable level of stability. This study provides evidence that the Vietnamese translation of the COACH tool is generally perceived to be clear and easy to understand and has acceptable stability. There is, however, a need to rephrase and add generic examples to clarify some items and to further review items with low ICC.

  17. Intra- and interobserver reliability of quantitative ultrasound measurement of the plantar fascia.

    Science.gov (United States)

    Rathleff, Michael Skovdal; Moelgaard, Carsten; Lykkegaard Olesen, Jens

    2011-01-01

    To determine intra- and interobserver reliability and measurement precision of sonographic assessment of plantar fascia thickness when using one, the mean of two, or the mean of three measurements. Two experienced observers scanned 20 healthy subjects twice with 60 minutes between test and retest. A GE LOGIQe ultrasound scanner was used in the study. The built-in software in the scanner was used to measure the thickness of the plantar fascia (PF). Reliability was calculated using intraclass correlation coefficient (ICC) and limits of agreement (LOA). Intraobserver reliability (ICC) using one measurement was 0.50 for one observer and 0.52 for the other, and using the mean of three measurements intraobserver reliability increased up to 0.77 and 0.67, respectively. Interobserver reliability (ICC) when using one measurement was 0.62 and increased to 0.82 when using the average of three measurements. LOA showed that when using the average of three measurements, LOA decreased to 0.6 mm, corresponding to 17.5% of the mean thickness of the PF. The results showed that reliability increases when using the mean of three measurements compared with one. Limits of agreement based on intratester reliability shows that changes in thickness that are larger than 0.6 mm can be considered actual changes in thickness and not a result of measurement error. Copyright © 2011 Wiley Periodicals, Inc.

  18. Reliable and valid assessment of performance in thoracoscopy

    DEFF Research Database (Denmark)

    Konge, Lars; Lehnert, Per; Hansen, Henrik Jessen

    2012-01-01

    BACKGROUND: As we move toward competency-based education in medicine, we have lagged in developing competency-based evaluation methods. In the era of minimally invasive surgery, there is a need for a reliable and valid tool dedicated to measure competence in video-assisted thoracoscopic surgery....... The purpose of this study is to create such an assessment tool, and to explore its reliability and validity. METHODS: An expert group of physicians created an assessment tool consisting of 10 items rated on a five-point rating scale. The following factors were included: economy and confidence of movement...

  19. Reliability of an e-PRO Tool of EORTC QLQ-C30 for Measurement of Health-Related Quality of Life in Patients With Breast Cancer: Prospective Randomized Trial.

    Science.gov (United States)

    Wallwiener, Markus; Matthies, Lina; Simoes, Elisabeth; Keilmann, Lucia; Hartkopf, Andreas D; Sokolov, Alexander N; Walter, Christina B; Sickenberger, Nina; Wallwiener, Stephanie; Feisst, Manuel; Gass, Paul; Fasching, Peter A; Lux, Michael P; Wallwiener, Diethelm; Taran, Florin-Andrei; Rom, Joachim; Schneeweiss, Andreas; Graf, Joachim; Brucker, Sara Y

    2017-09-14

    Breast cancer represents the most common malignant disease in women worldwide. As currently systematic palliative treatment only has a limited effect on survival rates, the concept of health-related quality of life (HRQoL) is gaining more and more importance in the therapy setting of metastatic breast cancer. One of the major patient-reported outcomes (PROs) for measuring HRQoL in patients with breast cancer is provided by the European Organization for Research and Treatment of Cancer (EORTC). Currently, paper-based surveys still predominate, as only a few reliable and validated electronic-based questionnaires are available. Facing the possibilities associated with evolving digitalization in medicine, validation of electronic versions of well-established PRO is essential in order to contribute to comprehensive and holistic oncological care and to ensure high quality in cancer research. The aim of this study was to analyze the reliability of a tablet-based measuring application for EORTC QLQ-C30 in German language in patients with adjuvant and (curative) metastatic breast cancer. Paper- and tablet-based questionnaires were completed by a total of 106 female patients with adjuvant and metastatic breast cancer recruited as part of the e-PROCOM study. All patients were required to complete the electronic- (e-PRO) and paper-based versions of the HRQoL EORTC QLQ-C30 questionnaire. A frequency analysis was performed to determine descriptive sociodemographic characteristics. Both dimensions of reliability (parallel forms reliability [Wilcoxon test] and test of internal consistency [Spearman rho and agreement rates for single items, Pearson correlation and Kendall tau for each scale]) were analyzed. High correlations were shown for both dimensions of reliability (parallel forms reliability and internal consistency) in the patient's response behavior between paper- and electronic-based questionnaires. Regarding the test of parallel forms reliability, no significant

  20. Reliability of Wearable Inertial Measurement Units to Measure Physical Activity in Team Handball.

    Science.gov (United States)

    Luteberget, Live S; Holme, Benjamin R; Spencer, Matt

    2018-04-01

    To assess the reliability and sensitivity of commercially available inertial measurement units to measure physical activity in team handball. Twenty-two handball players were instrumented with 2 inertial measurement units (OptimEye S5; Catapult Sports, Melbourne, Australia) taped together. They participated in either a laboratory assessment (n = 10) consisting of 7 team handball-specific tasks or field assessment (n = 12) conducted in 12 training sessions. Variables, including PlayerLoad™ and inertial movement analysis (IMA) magnitude and counts, were extracted from the manufacturers' software. IMA counts were divided into intensity bands of low (1.5-2.5 m·s -1 ), medium (2.5-3.5 m·s -1 ), high (>3.5 m·s -1 ), medium/high (>2.5 m·s -1 ), and total (>1.5 m·s -1 ). Reliability between devices and sensitivity was established using coefficient of variation (CV) and smallest worthwhile difference (SWD). Laboratory assessment: IMA magnitude showed a good reliability (CV = 3.1%) in well-controlled tasks. CV increased (4.4-6.7%) in more-complex tasks. Field assessment: Total IMA counts (CV = 1.8% and SWD = 2.5%), PlayerLoad (CV = 0.9% and SWD = 2.1%), and their associated variables (CV = 0.4-1.7%) showed a good reliability, well below the SWD. However, the CV of IMA increased when categorized into intensity bands (2.9-5.6%). The reliability of IMA counts was good when data were displayed as total, high, or medium/high counts. A good reliability for PlayerLoad and associated variables was evident. The CV of the previously mentioned variables was well below the SWD, suggesting that OptimEye's inertial measurement unit and its software are sensitive for use in team handball.

  1. Breast MRI used as a problem-solving tool reliably excludes malignancy

    International Nuclear Information System (INIS)

    Spick, Claudio; Szolar, Dieter H.M.; Preidler, Klaus W.; Tillich, Manfred; Reittner, Pia; Baltzer, Pascal A.

    2015-01-01

    Highlights: • Breast MRI reliably excludes malignancy in conventional BI-RADS 0 cases (NPV: 100%). • Malignancy rate in the BI-RADS 0 population is substantial with 13.5%. • Breast MRI used as a problem-solving tool reliably excludes malignancy. - Abstract: Purpose: To evaluate the diagnostic performance of breast MRI if used as a problem-solving tool in BI-RADS 0 cases. Material and methods: In this IRB-approved, single-center study, 687 women underwent high-resolution-3D, dynamic contrast-enhanced breast magnetic resonance imaging (MRI) between January 2012 and December 2012. Of these, we analyzed 111 consecutive patients (mean age, 51 ± 12 years; range, 20–83 years) categorized as BI-RADS 0. Breast MRI findings were stratified by clinical presentations, conventional imaging findings, and breast density. MRI results were compared to the reference standard, defined as histopathology or an imaging follow-up of at least 1 year. Results: One hundred eleven patients with BI-RADS 0 conventional imaging findings revealed 30 (27%) mammographic masses, 57 (51.4%) mammographic architectural distortions, five (4.5%) mammographic microcalcifications, 17 (15.3%) ultrasound-only findings, and two palpable findings without imaging correlates. There were 15 true-positive, 85 true-negative, 11 false-positive, and zero false-negative breast MRI findings, resulting in a sensitivity, specificity, PPV, and NPV of 100% (15/15), 88.5% (85/96), 57.7% (15/26), and 100% (85/85), respectively. Breast density and reasons for referral had no significant influence on the diagnostic performance of breast MRI (p > 0.05). Conclusion: Breast MRI reliably excludes malignancy in conventional BI-RADS 0 cases resulting in a NPV of 100% (85/85) and a PPV of 57.7% (15/26)

  2. Precision of lumbar intervertebral measurements: does a computer-assisted technique improve reliability?

    Science.gov (United States)

    Pearson, Adam M; Spratt, Kevin F; Genuario, James; McGough, William; Kosman, Katherine; Lurie, Jon; Sengupta, Dilip K

    2011-04-01

    Comparison of intra- and interobserver reliability of digitized manual and computer-assisted intervertebral motion measurements and classification of "instability." To determine if computer-assisted measurement of lumbar intervertebral motion on flexion-extension radiographs improves reliability compared with digitized manual measurements. Many studies have questioned the reliability of manual intervertebral measurements, although few have compared the reliability of computer-assisted and manual measurements on lumbar flexion-extension radiographs. Intervertebral rotation, anterior-posterior (AP) translation, and change in anterior and posterior disc height were measured with a digitized manual technique by three physicians and by three other observers using computer-assisted quantitative motion analysis (QMA) software. Each observer measured 30 sets of digital flexion-extension radiographs (L1-S1) twice. Shrout-Fleiss intraclass correlation coefficients for intra- and interobserver reliabilities were computed. The stability of each level was also classified (instability defined as >4 mm AP translation or 10° rotation), and the intra- and interobserver reliabilities of the two methods were compared using adjusted percent agreement (APA). Intraobserver reliability intraclass correlation coefficients were substantially higher for the QMA technique THAN the digitized manual technique across all measurements: rotation 0.997 versus 0.870, AP translation 0.959 versus 0.557, change in anterior disc height 0.962 versus 0.770, and change in posterior disc height 0.951 versus 0.283. The same pattern was observed for interobserver reliability (rotation 0.962 vs. 0.693, AP translation 0.862 vs. 0.151, change in anterior disc height 0.862 vs. 0.373, and change in posterior disc height 0.730 vs. 0.300). The QMA technique was also more reliable for the classification of "instability." Intraobserver APAs ranged from 87 to 97% for QMA versus 60% to 73% for digitized manual

  3. Reliability of reflectance measures in passive filters

    Science.gov (United States)

    Saldiva de André, Carmen Diva; Afonso de André, Paulo; Rocha, Francisco Marcelo; Saldiva, Paulo Hilário Nascimento; Carvalho de Oliveira, Regiani; Singer, Julio M.

    2014-08-01

    Measurements of optical reflectance in passive filters impregnated with a reactive chemical solution may be transformed to ozone concentrations via a calibration curve and constitute a low cost alternative for environmental monitoring, mainly to estimate human exposure. Given the possibility of errors caused by exposure bias, it is common to consider sets of m filters exposed during a certain period to estimate the latent reflectance on n different sample occasions at a certain location. Mixed models with sample occasions as random effects are useful to analyze data obtained under such setups. The intra-class correlation coefficient of the mean of the m measurements is an indicator of the reliability of the latent reflectance estimates. Our objective is to determine m in order to obtain a pre-specified reliability of the estimates, taking possible outliers into account. To illustrate the procedure, we consider an experiment conducted at the Laboratory of Experimental Air Pollution, University of São Paulo, Brazil (LPAE/FMUSP), where sets of m = 3 filters were exposed during 7 days on n = 9 different occasions at a certain location. The results show that the reliability of the latent reflectance estimates for each occasion obtained under homoskedasticity is km = 0.74. A residual analysis suggests that the within-occasion variance for two of the occasions should be different from the others. A refined model with two within-occasion variance components was considered, yielding km = 0.56 for these occasions and km = 0.87 for the remaining ones. To guarantee that all estimates have a reliability of at least 80% we require measurements on m = 10 filters on each occasion.

  4. Accuracy and Reliability of Cone-Beam Computed Tomography for Linear and Volumetric Mandibular Condyle Measurements. A Human Cadaver Study.

    Science.gov (United States)

    García-Sanz, Verónica; Bellot-Arcís, Carlos; Hernández, Virginia; Serrano-Sánchez, Pedro; Guarinos, Juan; Paredes-Gallardo, Vanessa

    2017-09-20

    The accuracy of Cone-Beam Computed Tomography (CBCT) on linear and volumetric measurements on condyles has only been assessed on dry skulls. The aim of this study was to evaluate the reliability and accuracy of linear and volumetric measurements of mandibular condyles in the presence of soft tissues using CBCT. Six embalmed cadaver heads were used. CBCT scans were taken, followed by the extraction of the condyles. The water displacement technique was used to calculate the volumes of the condyles and three linear measurements were made using a digital caliper, these measurements serving as the gold standard. Surface models of the condyles were obtained using a 3D scanner, and superimposed onto the CBCT images. Condyles were isolated on the CBCT render volume using the surface models as reference and volumes were measured. Linear measurements were made on CBCT slices. The CBCT method was found to be reliable for both volumetric and linear measurements (CV  0.90). Highly accurate values were obtained for the three linear measurements and volume. CBCT is a reliable and accurate method for taking volumetric and linear measurements on mandibular condyles in the presence of soft tissue, and so a valid tool for clinical diagnosis.

  5. Development and reliability of a Motivational Interviewing Scenarios Tool for Eating Disorders (MIST-ED) using a skills-based intervention among caregivers.

    Science.gov (United States)

    Sepulveda, Ana R; Wise, Caroline; Zabala, Maria; Todd, Gill; Treasure, Janet

    2013-12-01

    The aims of this study were to develop an eating disorder scenarios tool to assess the motivational interviewing (MI) skills of caregivers and evaluate the coding reliability of the instrument, and to test the sensitivity to change through a pre/post/follow-up design. The resulting Motivational Interview Scenarios Tool for Eating Disorders (MIST-ED) was administered to caregivers (n = 66) who were asked to provide oral and written responses before and after a skills-based intervention, and at a 3-month follow-up. Raters achieved excellent inter-rater reliability (intra-class correlations of 91.8% on MI adherent and 86.1% for MI non-adherent statements for written scenarios and 89.2%, and 85.3% for oral scenarios). Following the intervention, MI adherent statements increased (baseline = 9.4%, post = 61.5% and follow-up 47.2%) and non-MI adherent statements decreased (baseline = 90.6%, post = 38.5% and follow-up = 52.8%). This instrument can be used as a simple method to measure the acquisition of MI skills to improve coping and both response methods are adequate. The tool shows good sensitivity to improved skills. © 2013.

  6. Measuring Passenger Travel Time Reliability Using Smart Card Data

    NARCIS (Netherlands)

    Bagherian, M.; Cats, O.; van Oort, N.; Hickman, M

    2016-01-01

    Service reliability is a key performance measure for transit agencies in increasing their service quality and thus ridership. Conventional reliability metrics are established based on vehicle movements and thus do not adequately reflect passenger’s experience. In the past few years, the growing

  7. Measuring time and risk preferences: Reliability, stability, domain specificity

    NARCIS (Netherlands)

    Wölbert, E.M.; Riedl, A.M.

    2013-01-01

    To accurately predict behavior economists need reliable measures of individual time preferences and attitudes toward risk and typically need to assume stability of these characteristics over time and across decision domains. We test the reliability of two choice tasks for eliciting discount rates,

  8. Validity and reliability of a low-cost digital dynamometer for measuring isometric strength of lower limb.

    Science.gov (United States)

    Romero-Franco, Natalia; Jiménez-Reyes, Pedro; Montaño-Munuera, Juan A

    2017-11-01

    Lower limb isometric strength is a key parameter to monitor the training process or recognise muscle weakness and injury risk. However, valid and reliable methods to evaluate it often require high-cost tools. The aim of this study was to analyse the concurrent validity and reliability of a low-cost digital dynamometer for measuring isometric strength in lower limb. Eleven physically active and healthy participants performed maximal isometric strength for: flexion and extension of ankle, flexion and extension of knee, flexion, extension, adduction, abduction, internal and external rotation of hip. Data obtained by the digital dynamometer were compared with the isokinetic dynamometer to examine its concurrent validity. Data obtained by the digital dynamometer from 2 different evaluators and 2 different sessions were compared to examine its inter-rater and intra-rater reliability. Intra-class correlation (ICC) for validity was excellent in every movement (ICC > 0.9). Intra and inter-tester reliability was excellent for all the movements assessed (ICC > 0.75). The low-cost digital dynamometer demonstrated strong concurrent validity and excellent intra and inter-tester reliability for assessing isometric strength in the main lower limb movements.

  9. The Korean version of relative and absolute reliability of gait and balance assessment tools for patients with dementia in day care center and nursing home.

    Science.gov (United States)

    Lee, Han Suk; Park, Sun Wook; Chung, Hyung Kuk

    2017-11-01

    [Purpose] This study was aimed to determine the relative and absolute reliability of Korean version tools of the Berg Balance Scale (BBS), the Timed Up and Go (TUG), the Four-Meter Walking Test (4MWT) and the Groningen Meander Walking Test (GMWT) in patients with dementia. [Subjects and Methods] A total of 53 patients with dementia were tested on TUG, BBS, 4MWT and GMWT with a prospective cohort methodological design. Intra-class Correlation Coefficients (ICCs) to assess relative reliability and the standard error of measurement (SEM), minimal detectable change (MDC 95 ) and its percentage (MDC % ) to analyze the absolute reliability were calculated. [Results] Inter-rater reliability (ICC (2,3) ) of TUG, BBS and GMWT was 0.99 and that of 4MWT was 0.82. Inter-rater reliability was high for TUG, BBS and GMWT, with low SEM, MDC 95 , and MDC % . Inter-rater reliability was low for 4MWT, with high SEM, MDC 95 , and MDC % . Test-retest (ICC (2,3) ) of TUG, BBS and GMWT was 0.96-0.99 and Test-retest (ICC (2,3) ) of 4MWT was 0.85. The test-retest was high for TUG, BBS and GMWT, with low SEM, MDC 95 , and MDC % , but it was low for 4MWT, with high SEM, MDC 95 , and MDC % . [Conclusion] The relative reliability was high for all the assessment tools. The absolute reliability has a reasonable level of stability except the 4MWT.

  10. Reliability and concurrent validity of the iPhone® Compass application to measure thoracic rotation range of motion (ROM) in healthy participants

    Science.gov (United States)

    Schram, Ben; Cox, Alistair J.; Anderson, Sarah L.; Keogh, Justin

    2018-01-01

    Background Several water-based sports (swimming, surfing and stand up paddle boarding) require adequate thoracic mobility (specifically rotation) in order to perform the appropriate activity requirements. The measurement of thoracic spine rotation is problematic for clinicians due to a lack of convenient and reliable measurement techniques. More recently, smartphones have been used to quantify movement in various joints in the body; however, there appears to be a paucity of research using smartphones to assess thoracic spine movement. Therefore, the aim of this study is to determine the reliability (intra and inter rater) and validity of the iPhone® app (Compass) when assessing thoracic spine rotation ROM in healthy individuals. Methods A total of thirty participants were recruited for this study. Thoracic spine rotation ROM was measured using both the current clinical gold standard, a universal goniometer (UG) and the Smart Phone Compass app. Intra-rater and inter-rater reliability was determined with a Intraclass Correlation Coefficient (ICC) and associated 95% confidence intervals (CI). Validation of the Compass app in comparison to the UG was measured using Pearson’s correlation coefficient and levels of agreement were identified with Bland–Altman plots and 95% limits of agreement. Results Both the UG and Compass app measurements both had excellent reproducibility for intra-rater (ICC 0.94–0.98) and inter-rater reliability (ICC 0.72–0.89). However, the Compass app measurements had higher intra-rater reliability (ICC = 0.96 − 0.98; 95% CI [0.93–0.99]; vs. ICC = 0.94 − 0.98; 95% CI [0.88–0.99]) and inter-rater reliability (ICC = 0.87 − 0.89; 95% CI [0.74–0.95] vs. ICC = 0.72 − 0.82; 95% CI [0.21–0.94]). A strong and significant correlation was found between the UG and the Compass app, demonstrating good concurrent validity (r = 0.835, p reliable tool for measuring thoracic spine rotation which produces greater

  11. A multisource feedback tool to assess ward round leadership skills of senior paediatric trainees: (2) Testing reliability and practicability.

    Science.gov (United States)

    Goodyear, Helen M; Lakshminarayana, Indumathy; Wall, David; Bindal, Taruna

    2015-05-01

    A five-domain multisource feedback (MSF) tool was previously developed in 2009-2010 by the authors to assess senior paediatric trainees' ward round leadership skills. To determine whether this MSF tool is practicable and reliable, whether individuals' feedback varies over time and trainees' views of the tool. The MSF tool was piloted (April-July 2011) and field tested (September 2011-February 2013) with senior paediatric trainees. A focus group held at the end of field testing obtained trainees' views of the tool. In field testing, 96/115 (84%) trainees returned 633 individual assessments from three different ward rounds over 18 months. The MSF tool had high reliability (Cronbach's α 0.84, G coefficient 0.8 for three raters). In all five domains, data were shifted to the right with scores of 3 (good) and 4 (excellent). Consultants gave significantly lower scores (p<0.001), as did trainees for self-assessment (p<0.001). There was no significant change in MSF scores over 18 months but comments showed that trainees' performance improved. Trainees valued these comments and the MSF tool but had concerns about time taken for feedback and confusion about tool use and the paediatric assessment strategy. A five-domain MSF tool was found to be reliable on pilot and field testing, practicable to use and liked by trainees. Comments on performance were more helpful than scores in giving trainees feedback. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Automated reliability assessment for spectroscopic redshift measurements

    Science.gov (United States)

    Jamal, S.; Le Brun, V.; Le Fèvre, O.; Vibert, D.; Schmitt, A.; Surace, C.; Copin, Y.; Garilli, B.; Moresco, M.; Pozzetti, L.

    2018-03-01

    Context. Future large-scale surveys, such as the ESA Euclid mission, will produce a large set of galaxy redshifts (≥106) that will require fully automated data-processing pipelines to analyze the data, extract crucial information and ensure that all requirements are met. A fundamental element in these pipelines is to associate to each galaxy redshift measurement a quality, or reliability, estimate. Aim. In this work, we introduce a new approach to automate the spectroscopic redshift reliability assessment based on machine learning (ML) and characteristics of the redshift probability density function. Methods: We propose to rephrase the spectroscopic redshift estimation into a Bayesian framework, in order to incorporate all sources of information and uncertainties related to the redshift estimation process and produce a redshift posterior probability density function (PDF). To automate the assessment of a reliability flag, we exploit key features in the redshift posterior PDF and machine learning algorithms. Results: As a working example, public data from the VIMOS VLT Deep Survey is exploited to present and test this new methodology. We first tried to reproduce the existing reliability flags using supervised classification in order to describe different types of redshift PDFs, but due to the subjective definition of these flags (classification accuracy 58%), we soon opted for a new homogeneous partitioning of the data into distinct clusters via unsupervised classification. After assessing the accuracy of the new clusters via resubstitution and test predictions (classification accuracy 98%), we projected unlabeled data from preliminary mock simulations for the Euclid space mission into this mapping to predict their redshift reliability labels. Conclusions: Through the development of a methodology in which a system can build its own experience to assess the quality of a parameter, we are able to set a preliminary basis of an automated reliability assessment for

  13. Measuring the suffering of end-stage dementia: reliability and validity of the Mini-Suffering State Examination.

    Science.gov (United States)

    Aminoff, Bechor Z; Purits, Elena; Noy, Shlomo; Adunsky, Abraham

    2004-01-01

    Assessment of suffering is extremely important in dying end-stage dementia patients (ESDP). We have developed and examined the reliability and validity of the Mini-Suffering State Examination (MSSE), in 103 consecutive bedridden ESDP. Main outcome measures included inter-observer reliability and concurrent validity. Reliability of the MSSE questionnaire was satisfactory, with Cronbach alpha values of 0.735 and 0.718 for the two physicians (Ph-1, Ph-2), respectively. The kappa agreement coefficient was 0.791. There was a high agreement for seven items (kappa 0.882-0.972) and a substantial agreement for the other three items (kappa 0.621-0.682) of the MSSE. MSSE was validated versus the comfort assessment in dying with dementia (CAD-EOLD) scale and resulted in a significant Pearson correlation (r=-0.796, P<0.001). We conclude that the MSSE scale is a reliable and valid clinical tool, recommended for evaluating the severity of the patient's condition and the level of suffering of ESDP. Use of MSSE may improve medical management and facilitate communication between patients and caregivers.

  14. The TiltMeter app is a novel and accurate measurement tool for the weight bearing lunge test.

    Science.gov (United States)

    Williams, Cylie M; Caserta, Antoni J; Haines, Terry P

    2013-09-01

    The weight bearing lunge test is increasing being used by health care clinicians who treat lower limb and foot pathology. This measure is commonly established accurately and reliably with the use of expensive equipment. This study aims to compare the digital inclinometer with a free app, TiltMeter on an Apple iPhone. This was an intra-rater and inter-rater reliability study. Two raters (novice and experienced) conducted the measurements in both a bent knee and straight leg position to determine the intra-rater and inter-rater reliability. Concurrent validity was also established. Allied health practitioners were recruited as participants from the workplace. A preconditioning stretch was conducted and the ankle range of motion was established with the weight bearing lunge test position with firstly the leg straight and secondly with the knee bent. The measurement device and each participant were randomised during measurement. The intra-rater reliability and inter-rater reliability for the devices and in both positions were all over ICC 0.8 except for one intra-rater measure (Digital inclinometer, novice, ICC 0.65). The inter-rater reliability between the digital inclinometer and the tilmeter was near perfect, ICC 0.96 (CI: 0.898-0.983); Concurrent validity ICC between the two devices was 0.83 (CI: -0.740 to 0.445). The use of the Tiltmeter app on the iPhone is a reliable and inexpensive tool to measure the available ankle range of motion. Health practitioners should use caution in applying these findings to other smart phone equipment if surface areas are not comparable. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  15. 3D cutting tool-wear monitoring in the process

    Energy Technology Data Exchange (ETDEWEB)

    Cerce, Luka; Pusavec, Franci; Kopac Janez [University of Ljubljana, Askerceva (Slovenia)

    2015-09-15

    The tool-wear of cutting tools has a very strong impact on the product quality as well as efficiency of the machining processes. Therefore, it in-the process characterization is crucial. This paper presents an innovative and reliable direct measuring procedure for measuring spatial cutting tool-wear with usage of laser profile sensor. The technique provides possibility for determination of 3D wear profiles, as advantage to currently used 2D techniques. The influence of the orientation of measurement head on the accuracy and the amount of captured reliable data was examined and the optimal setup of the measuring system was defined. Further, a special clamping system was designed to mount the measurement device on the machine tool turret. To test the measurement system, tool-life experiment was performed. Additionally, a new tool-life criterion was developed, including spatial characteristics of the tool-wear. The results showed that novel tool-wear and tool-life diagnostic represent objective and robust estimator of the machining process. Additionally, such automation of tool-wear diagnostics on machine tool provides higher productivity and quality of the machining process.

  16. A comparison of manual anthropometric measurements with Kinect-based scanned measurements in terms of precision and reliability.

    Science.gov (United States)

    Bragança, Sara; Arezes, Pedro; Carvalho, Miguel; Ashdown, Susan P; Castellucci, Ignacio; Leão, Celina

    2018-01-01

    Collecting anthropometric data for real-life applications demands a high degree of precision and reliability. It is important to test new equipment that will be used for data collectionOBJECTIVE:Compare two anthropometric data gathering techniques - manual methods and a Kinect-based 3D body scanner - to understand which of them gives more precise and reliable results. The data was collected using a measuring tape and a Kinect-based 3D body scanner. It was evaluated in terms of precision by considering the regular and relative Technical Error of Measurement and in terms of reliability by using the Intraclass Correlation Coefficient, Reliability Coefficient, Standard Error of Measurement and Coefficient of Variation. The results obtained showed that both methods presented better results for reliability than for precision. Both methods showed relatively good results for these two variables, however, manual methods had better results for some body measurements. Despite being considered sufficiently precise and reliable for certain applications (e.g. apparel industry), the 3D scanner tested showed, for almost every anthropometric measurement, a different result than the manual technique. Many companies design their products based on data obtained from 3D scanners, hence, understanding the precision and reliability of the equipment used is essential to obtain feasible results.

  17. Validity and Reliability of Knowledge, Attitude and Behavior Assessment Tool Among Vulnerable Women Concerning Sexually Transmitted Diseases

    Directory of Open Access Journals (Sweden)

    Zahra Boroumandfar

    2016-05-01

    Full Text Available Objective: The study aimed to design and evaluate the content and face validity, and reliability of knowledge, attitude, and behavior questionnaire on preventive behaviors among vulnerable women concerning sexually transmitted diseases (STDs.Materials and methods: This cross-sectional study was carried out in two phases of an action research. In the first phase, to explain STDs preventive domains, 20 semi- structured interviews were conducted with the vulnerable women, residing at women prison and women referred to counseling centers. After analyzing content of interviews, three domains were identified: improve their knowledge, modify their attitude and change their behaviors. In the second phase, the questionnaire was designed and tested in a pilot study. Then, its content validity was evaluated. Face validity and reliability of the questionnaire were assessed by test re- test method and Cronbach alpha respectively.Results: Index of content validity in each three domain of the questionnaire (knowledge, attitude and behavior concerning STDs was obtained over 0.6. Overall content validity index was 0.86 in all three domains of the questionnaire. The Cronbach’s alpha as reliability of questionnaire was 0.80 for knowledge, 0.79 for attitude and 0.85 for behavior.Conclusion: The results showed that the designed questionnaire was a valid and reliable tool to measure knowledge, attitude and behavior of vulnerable women, predisposed to risk of STDs.

  18. The constant failure rate model for fault tree evaluation as a tool for unit protection reliability assessment

    International Nuclear Information System (INIS)

    Vichev, S.; Bogdanov, D.

    2000-01-01

    The purpose of this paper is to introduce the fault tree analysis method as a tool for unit protection reliability estimation. The constant failure rate model applies for making reliability assessment, and especially availability assessment. For that purpose an example for unit primary equipment structure and fault tree example for simplified unit protection system is presented (author)

  19. Validity and Reliability of Persian Version of Johns Hopkins Fall Risk Assessment Tool among Aged People

    Directory of Open Access Journals (Sweden)

    hadi hojati

    2018-04-01

    Full Text Available Background & Aim: It is crucial to identify aged patients in risk of falls in clinical settings. Johns Hopkins Fall Risk Assessment Tool (JHFRAT is one of most applied international instrument to assess elderly patients for the risk of falls. The aim of this study was to evaluate reliability and internal consistency of the JHFRAT. Methods & Materials: In this cross-sectional study for validity assessment of the tool, WHO’s standard protocol was applied for translation-back translation of the tool. Face and content validity of the tool was confirmed by ten person of expert faculty members for its applicability in clinical setting. In this pilot study, the inclusion criteria were being 60 or more years old, hospitalized in the last 8 hours prior to assessment and in proper cognitive condition assessed by MMSE. Subjects of the study were (n=70 elderly patients who were newly hospitalized in Shahroud Emam Hossein Hospital. Data were analyzed using SPSS software- version 16. Internal consistency of the tool was calculated by Cronbach’s alpha. Results: According to the results of the study Persian version of JHFRAT was a valid tool for application on clinical setting. The Persian version of the tool had Cronbach’s alpha equal to 0/733. Conclusion: Based on the findings of the current study, it can be concluded that Persian version of the JHFRAT is a valid and reliable tool to be applied for assessment of elderly senior citizens on admission in any clinical settings.

  20. Reliability of Measuring Lumbar Lordosis, Flexion and Extension Using Dual Inclinometer in Healthy Subjects and Patients with Non-Specific Chronic Low Back Pain

    Directory of Open Access Journals (Sweden)

    Samira Garmabi

    2012-07-01

    Full Text Available Objective: Accurate assessment of lumbar range of motion is of great value for both evaluating lumbar functions and monitoring treatment progress. Recent research indicates that there is no general consensus on the most valid and reliable method of measuring spinal range of motion. The purpose of this study was to determine the intra-rater reliability of lumbar flexion and extension measurements (within-day and between-days using the dual inclinometer technique.   Materials & Methods: Lumbar flexion and extension of 22 women (14 healthy and 8 with low back pain, were measured by the same examiner on three occasions. The first two measurements were taken with half an hour apart on the first occasion to assess the within-day reliability and the third measurement was taken one week later to assess the between-days reliability.  Results: Within-day lumbar lordosis, flexion and extension measurements using dual inclinometer technique were shown to be very reliable with high Intraclass Correlation Coefficients (ICC values (ICC were 98%, 77% and 69% for lordosis, flexion and extension measurements, respectively in healthy subjects and 94%, 95% and 69% for lordosis, flexion and extension measurements, respectively in patients group. Between-Days measurements also demonstrated high reliability with the high values of ICC (ICC were 96%, 70% and 67% for lordosis, flexion and extension measurements, in healthy subjects and 91%, 71% and 66% for lordosis, flexion and extension measurements, respectively in patients group. Conclusion: The results indicated that, the dual inclinometer technique appears to be a highly reliable method for measuring lumbar lordosis, flexion and extension and can be used as a reliable tool in the assessment of lumbar range of motion and monitoring therapeutic interventions.

  1. Reliability of impedance cardiography in measuring central haemodynamics

    DEFF Research Database (Denmark)

    Mehlsen, J; Bonde, J; Stadeager, C

    1991-01-01

    The purpose of the study described here was to investigate the reliability of impedance cardiography (IC) in measuring cardiac output (CO) and central blood volume. Absolute values and changes in these variables obtained by impedance cardiography and by isotope- or thermodilution techniques were...... suitable for repeated measurements in studies on the haemodynamic effects of physiological or pharmacological intervention. Impedance cardiography is sufficiently reliable for comparison of absolute values of CO between different groups of patients. We cannot recommend impedance cardiography...... healthy subjects and in 25 unmedicated patients with ischaemic heart disease. We obtained significant correlations between absolute values (y = 0.68x + 1.48) and changes (y = 1.00x + 0.0003) in CO measured by IC and isotope- or thermodilution. IC significantly overestimated absolute values of CO (P less...

  2. Reliability of the Hazelbaker Assessment Tool for Lingual Frenulum Function

    Directory of Open Access Journals (Sweden)

    James Jennifer P

    2006-03-01

    Full Text Available Abstract Background About 3% of infants are born with a tongue-tie which may lead to breastfeeding problems such as ineffective latch, painful attachment or poor weight gain. The Hazelbaker Assessment Tool for Lingual Frenulum Function (HATLFF has been developed to give a quantitative assessment of the tongue-tie and recommendation about frenotomy (release of the frenulum. The aim of this study was to assess the inter-rater reliability of the HATLFF. Methods Fifty-eight infants referred to the Breastfeeding Education and Support Services (BESS at The Royal Women's Hospital for assessment of tongue-tie and 25 control infants were assessed by two clinicians independently. Results The Appearance items received kappas between about 0.4 to 0.6, which represents "moderate" reliability. The first three Function items (lateralization, lift and extension of tongue had kappa values over 0.65 which indicates "substantial" agreement. The four Function items relating to infant sucking (spread, cupping, peristalsis and snapback received low kappa values with insignificant p values. There was 96% agreement between the two assessors on the recommendation for frenotomy (kappa 0.92, excellent agreement. The study found that the Function Score can be more simply assessed using only the first three function items (ie not scoring the sucking items, with a cut-off of ≤4 for recommendation of frenotomy. Conclusion We found that the HATLFF has a high reliability in a study of infants with tongue-tie and control infants

  3. Reliability of EEG Interactions Differs between Measures and Is Specific for Neurological Diseases

    Directory of Open Access Journals (Sweden)

    Yvonne Höller

    2017-07-01

    Full Text Available Alterations of interaction (connectivity of the EEG reflect pathological processes in patients with neurologic disorders. Nevertheless, it is questionable whether these patterns are reliable over time in different measures of interaction and whether this reliability of the measures is the same across different patient populations. In order to address this topic we examined 22 patients with mild cognitive impairment, five patients with subjective cognitive complaints, six patients with right-lateralized temporal lobe epilepsy, seven patients with left lateralized temporal lobe epilepsy, and 20 healthy controls. We calculated 14 measures of interaction from two EEG-recordings separated by 2 weeks. In order to characterize test-retest reliability, we correlated these measures for each group and compared the correlations between measures and between groups. We found that both measures of interaction as well as groups differed from each other in terms of reliability. The strongest correlation coefficients were found for spectrum, coherence, and full frequency directed transfer function (average rho > 0.9. In the delta (2–4 Hz range, reliability was lower for mild cognitive impairment compared to healthy controls and left lateralized temporal lobe epilepsy. In the beta (13–30 Hz, gamma (31–80 Hz, and high gamma (81–125 Hz frequency ranges we found decreased reliability in subjective cognitive complaints compared to mild cognitive impairment. In the gamma and high gamma range we found increased reliability in left lateralized temporal lobe epilepsy patients compared to healthy controls. Our results emphasize the importance of documenting reliability of measures of interaction, which may vary considerably between measures, but also between patient populations. We suggest that studies claiming clinical usefulness of measures of interaction should provide information on the reliability of the results. In addition, differences between patient

  4. Answering the call: a tool that measures functional breast cancer literacy.

    Science.gov (United States)

    Williams, Karen Patricia; Templin, Thomas N; Hines, Resche D

    2013-01-01

    There is a need for health care providers and health care educators to ensure that the messages they communicate are understood. The purpose of this research was to test the reliability and validity, in a culturally diverse sample of women, of a revised Breast Cancer Literacy Assessment Tool (Breast-CLAT) designed to measure functional understanding of breast cancer in English, Spanish, and Arabic. Community health workers verbally administered the 35-item Breast-CLAT to 543 Black, Latina, and Arab American women. A confirmatory factor analysis using a 2-parameter item response theory model was used to test the proposed 3-factor Breast-CLAT (awareness, screening and knowledge, and prevention and control). The confirmatory factor analysis using a 2-parameter item response theory model had a good fit (TLI = .91, RMSEA = .04) to the proposed 3-factor structure. The total scale reliability ranged from .80 for Black participants to .73 for total culturally diverse sample. The three subscales were differentially predictive of family history of cancer. The revised Breast-CLAT scales demonstrated internal consistency reliability and validity in this multiethnic, community-based sample.

  5. Reliability and relationship of radiographic measurements in hallux valgus.

    Science.gov (United States)

    Lee, Kyoung Min; Ahn, Soyeon; Chung, Chin Youb; Sung, Ki Hyuk; Park, Moon Seok

    2012-09-01

    Although various radiographic measurements have been developed and used for evaluating hallux valgus, not all are universally believed to be necessary and their relationships have not been clearly established. Determining which are related could provide some insight into which might be useful and which would not. We investigated the reliability of eight radiographic measurements used to evaluate hallux valgus, and determined which were correlated and which predicted the hallux valgus angle. We determined eight radiographic indices for 732 patients (mean age, 51 years; SD, 17 years; 107 males and 625 females) with hallux valgus: hallux valgus angle, intermetatarsal angle, hallux interphalangeal angle, distal metatarsal articular angle, proximal phalangeal articular angle, simplified metatarsus adductus angle, first metatarsal protrusion distance, and sesamoid rotation angle. Intraobserver and interobserver reliabilities of each radiographic measurement were analyzed on 36 feet from 36 randomly selected patients. Correlations among the radiographic measurements were analyzed. Radiographic measurements predicting hallux valgus angle were evaluated using multiple regression analysis. Hallux valgus angle had the highest reliability, whereas the distal metatarsal articular angle and simplified metatarsus adductus angle had the lowest. Distal metatarsal articular angle, intermetatarsal angle, and sesamoid rotation angle had the highest correlations with hallux valgus angle. Distal metatarsal articular angle correlated with sesamoid rotation angle. The intermetatarsal angle, interphalangeal angle, distal metatarsal articular angle, first metatarsal protrusion distance, sesamoid rotation angle, and metatarsus adductus angle predicted the hallux valgus angle. We suggest using hallux valgus angle, intermetatarsal angle, interphalangeal angle, sesamoid rotation angle, and first metatarsal protrusion distance considering their reliability and prediction of the deformity.

  6. Reliability Calculations

    DEFF Research Database (Denmark)

    Petersen, Kurt Erling

    1986-01-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety...... and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic...... approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very...

  7. Radiographic measurement reliability of lumbar lordosis in ankylosing spondylitis.

    Science.gov (United States)

    Lee, Jung Sub; Goh, Tae Sik; Park, Shi Hwan; Lee, Hong Seok; Suh, Kuen Tak

    2013-04-01

    Intraobserver and interobserver reliabilities of the several different methods to measure lumbar lordosis have been reported. However, it has not been studied sofar in patients with ankylosing spondylitis (AS). We evaluated the inter and intraobserver reliabilities of six specific measures of global lumbar lordosis in patients with AS. Ninety-one consecutive patients with AS who met the most recently modified New York criteria were enrolled and underwent anteroposterior and lateral radiographs of whole spine. The radiographs were divided into non-ankylosis (no bony bridge in the lumbar spine), incomplete ankylosis (lumbar spines were partially connected by bony bridge) and complete ankylosis groups to evaluate the reliability of the Cobb L1-S1, Cobb L1-L5, centroid, posterior tangent L1-S1, posterior tangent L1-L5, and TRALL methods. The radiographs were composed of 39 non-ankylosis, 27 incomplete ankylosis and 25 complete ankylosis. Intra- and inter-class correlation coefficients (ICCs) of all six methods were generally high. The ICCs were all ≥0.77 (excellent) for the six radiographic methods in the combined group. However, a comparison of the ICCs, 95 % confidence intervals and mean absolute difference (MAD) between groups with varying degrees of ankylosis showed that the reliability of the lordosis measurements decreased in proportion to the severity of ankylosis. The Cobb L1-S1, Cobb L1-L5 and posterior tangent L1-S1 method demonstrated higher ICCs for both inter and intraobserver comparisons and the other methods showed lower ICCs in all groups. The intraobserver MAD was similar in the Cobb L1-S1 and Cobb L1-L5 (2.7°-4.3°), but the other methods showed higher intraobserver MAD. Interobserver MAD of Cobb L1-L5 only showed low in all group. These results are the first to provide a reliability analysis of different global lumbar lordosis measurement methods in AS. The findings in this study demonstrated that the Cobb L1-L5 method is reliable for measuring

  8. Reliability and concurrent validity of the iPhone® Compass application to measure thoracic rotation range of motion (ROM in healthy participants

    Directory of Open Access Journals (Sweden)

    James Furness

    2018-03-01

    .5°, +15.3°. The UG was found to consistently measure higher values than the compass app (mean difference 2.8°, P < 0.001. Conclusion This study reveals that the iPhone® app (Compass is a reliable tool for measuring thoracic spine rotation which produces greater reproducibility of measurements both within and between raters than a UG. As a significant positive correlation exists between the Compass app and UG, this supports the use of either device in clinical practice as a reliable and valid tool to measure thoracic rotation. Considering the levels of agreement are clinically unacceptable, the devices should not be used interchangeably for initial and follow up measurements.

  9. RELIABILITY OF ANKLE-FOOT MORPHOLOGY, MOBILITY, STRENGTH, AND MOTOR PERFORMANCE MEASURES.

    Science.gov (United States)

    Fraser, John J; Koldenhoven, Rachel M; Saliba, Susan A; Hertel, Jay

    2017-12-01

    Assessment of foot posture, morphology, intersegmental mobility, strength and motor control of the ankle-foot complex are commonly used clinically, but measurement properties of many assessments are unclear. To determine test-retest and inter-rater reliability, standard error of measurement, and minimal detectable change of morphology, joint excursion and play, strength, and motor control of the ankle-foot complex. Reliability study. 24 healthy, recreationally-active young adults without history of ankle-foot injury were assessed by two clinicians on two occasions, three to ten days apart. Measurement properties were assessed for foot morphology (foot posture index, total and truncated length, width, arch height), joint excursion (weight-bearing dorsiflexion, rearfoot and hallux goniometry, forefoot inclinometry, 1 st metatarsal displacement) and joint play, strength (handheld dynamometry), and motor control rating during intrinsic foot muscle (IFM) exercises. Clinician order was randomized using a Latin Square. The clinicians performed independent examinations and did not confer on the findings for the duration of the study. Test-retest and inter-tester reliability and agreement was assessed using intraclass correlation coefficients (ICC 2,k ) and weighted kappa ( K w ). Test-retest reliability ICC were as follows: morphology: .80-1.00, joint excursion: .58-.97, joint play: -.67-.84, strength: .67-.92, IFM motor rating: K W -.01-.71. Inter-rater reliability ICC were as follows: morphology: .81-1.00, joint excursion: .32-.97, joint play: -1.06-1.00, strength: .53-.90, and IFM motor rating: K w .02-.56. Measures of ankle-foot posture, morphology, joint excursion, and strength demonstrated fair to excellent test-retest and inter-rater reliability. Test-retest reliability for rating of perceived difficulty and motor performance was good to excellent for short-foot, toe-spread-out, and hallux exercises and poor to fair for lesser toe extension. Joint play measures had

  10. Is the Job Satisfaction Survey a good tool to measure job satisfaction amongst health workers in Nepal? Results of a validation analysis.

    Science.gov (United States)

    Batura, Neha; Skordis-Worrall, Jolene; Thapa, Rita; Basnyat, Regina; Morrison, Joanna

    2016-07-27

    Job satisfaction is an important predictor of an individual's intention to leave the workplace. It is increasingly being used to consider the retention of health workers in low-income countries. However, the determinants of job satisfaction vary in different contexts, and it is important to use measurement methods that are contextually appropriate. We identified a measurement tool developed by Paul Spector, and used mixed methods to assess its validity and reliability in measuring job satisfaction among maternal and newborn health workers (MNHWs) in government facilities in rural Nepal. We administered the tool to 137 MNHWs and collected qualitative data from 78 MNHWs, and district and central level stakeholders to explore definitions of job satisfaction and factors that affected it. We calculated a job satisfaction index for all MNHWs using quantitative data and tested for validity, reliability and sensitivity. We conducted qualitative content analysis and compared the job satisfaction indices with qualitative data. Results from the internal consistency tests offer encouraging evidence of the validity, reliability and sensitivity of the tool. Overall, the job satisfaction indices reflected the qualitative data. The tool was able to distinguish levels of job satisfaction among MNHWs. However, the work environment and promotion dimensions of the tool did not adequately reflect local conditions. Further, community fit was found to impact job satisfaction but was not captured by the tool. The relatively high incidence of missing responses may suggest that responding to some statements was perceived as risky. Our findings indicate that the adapted job satisfaction survey was able to measure job satisfaction in Nepal. However, it did not include key contextual factors affecting job satisfaction of MNHWs, and as such may have been less sensitive than a more inclusive measure. The findings suggest that this tool can be used in similar settings and populations, with the

  11. Reliability of cervical lordosis measurement techniques on long-cassette radiographs.

    Science.gov (United States)

    Janusz, Piotr; Tyrakowski, Marcin; Yu, Hailong; Siemionow, Kris

    2016-11-01

    Lateral radiographs are commonly used to assess cervical sagittal alignment. Three assessment methods have been described and are commonly utilized in clinical practice. These methods are described for perfect lateral cervical radiographs, however in everyday practice radiograph quality varies. The aim of this study was to compare the reliability and reproducibility of 3 cervical lordosis (CL) measurement methods. Forty-four standing lateral radiographs were randomly chosen from a lateral long-cassette radiograph database. Measurements of CL were performed with: Cobb method C2-C7 (CM), C2-C7 posterior tangent method (PTM), sum of posterior tangent method for each segment (SPTM). Three independent orthopaedic surgeons measured CL using the three methods on 44 lateral radiographs. One researcher used the three methods to measured CL three times at 4-week time intervals. Agreement between the methods as well as their intra- and interobserver reliability were tested and quantified by intraclass correlation coefficient (ICC) and median error for a single measurement (SEM). ICC of 0.75 or more reflected an excellent agreement/reliability. The results were compared with repeated ANOVA test, with p  0.05). All three methods appeared to be highly reliable. Although, high agreement between all measurement methods was shown, we do not recommend using Cobb measurement method interchangeably with PTM or SPTM within a single study as this could lead to error, whereas, such a comparison between tangent methods can be considered.

  12. The Construct Validity and Reliability of an Assessment Tool for Competency in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Patorn Piromchai

    2014-01-01

    Full Text Available Introduction. We introduce a rating tool that objectively evaluates the skills of surgical trainees performing cochlear implant surgery. Methods. Seven residents and seven experts performed cochlear implant surgery sessions from mastoidectomy to cochleostomy on a standardized virtual reality temporal bone. A total of twenty-eight assessment videos were recorded and two consultant otolaryngologists evaluated the performance of each participant using these videos. Results. Interrater reliability was calculated using the intraclass correlation coefficient for both the global and checklist components of the assessment instrument. The overall agreement was high. The construct validity of this instrument was strongly supported by the significantly higher scores in the expert group for both components. Conclusion. Our results indicate that the proposed assessment tool for cochlear implant surgery is reliable, accurate, and easy to use. This instrument can thus be used to provide objective feedback on overall and task-specific competency in cochlear implantation.

  13. Measuring reliability under epistemic uncertainty: Review on non-probabilistic reliability metrics

    Directory of Open Access Journals (Sweden)

    Kang Rui

    2016-06-01

    Full Text Available In this paper, a systematic review of non-probabilistic reliability metrics is conducted to assist the selection of appropriate reliability metrics to model the influence of epistemic uncertainty. Five frequently used non-probabilistic reliability metrics are critically reviewed, i.e., evidence-theory-based reliability metrics, interval-analysis-based reliability metrics, fuzzy-interval-analysis-based reliability metrics, possibility-theory-based reliability metrics (posbist reliability and uncertainty-theory-based reliability metrics (belief reliability. It is pointed out that a qualified reliability metric that is able to consider the effect of epistemic uncertainty needs to (1 compensate the conservatism in the estimations of the component-level reliability metrics caused by epistemic uncertainty, and (2 satisfy the duality axiom, otherwise it might lead to paradoxical and confusing results in engineering applications. The five commonly used non-probabilistic reliability metrics are compared in terms of these two properties, and the comparison can serve as a basis for the selection of the appropriate reliability metrics.

  14. Reliability and Normative Reference Values for the Vestibular/Ocular Motor Screening (VOMS) Tool in Youth Athletes.

    Science.gov (United States)

    Moran, Ryan N; Covassin, Tracey; Elbin, R J; Gould, Dan; Nogle, Sally

    2018-05-01

    The Vestibular/Ocular Motor Screening (VOMS) measure is a newly developed vestibular and ocular motor symptom provocation screening tool for sport-related concussions. Baseline data, psychometric properties, and reliability of the VOMS are needed to further understand the applications of this tool, especially in the youth population, where research is scarce. To establish normative data and document the internal consistency and false-positive rate of the VOMS in a sample of nonconcussed youth athletes. Cross-sectional study; Level of evidence, 3. A total of 423 youth athletes (male = 278, female = 145) between the ages of 8 and 14 years completed baseline VOMS screening before the start of their respective sport seasons. Internal consistency was measured with Cronbach α and inter-item correlations. Approximately 60% of youth athletes reported no symptom provocation on baseline VOMS assessment, with 9% to 13% scoring over the cutoff levels (score of ≥2 for any individual VOMS symptom, near point convergence distance of ≥5 cm). The VOMS displayed a high internal consistency (Cronbach α = .97) at baseline among youth athletes. The current findings provide preliminary support for the implementation of VOMS baseline assessment into clinical practice, due to a high internal consistency, strong relationships between VOMS items, and a low false-positive rate at baseline in youth athletes.

  15. Clinical assessment of scapular positioning in musicians: an intertester reliability study.

    Science.gov (United States)

    Struyf, Filip; Nijs, Jo; De Coninck, Kris; Giunta, Marco; Mottram, Sarah; Meeusen, Romain

    2009-01-01

    The reliability of the measurement of the distance between the posterior border of the acromion and the wall and the reliability of the modified lateral scapular slide test have not been studied. Overall, the reliability of the clinical tools used to assess scapular positioning has not been studied in musicians. To examine the intertester reliability of scapular observation and 2 clinical tests for the assessment of scapular positioning in musicians. Intertester reliability study. University research laboratory. Thirty healthy student musicians at a single university. Two assessors performed a standardized observation protocol, the measurement of the distance between the posterior border of the acromion and the wall, and the modified lateral scapular slide test. Each assessor was blinded to the other's findings. The intertester reliability coefficients (kappa) for the observation in relaxed position, during unloaded movement, and during loaded movement were 0.41, 0.63, and 0.36, respectively. The kappa values for the observation of tilting and winging at rest were 0.48 and 0.42, respectively; during unloaded movement, the kappa values were 0.52 and 0.78, respectively; and with a 1-kg load, the kappa values were 0.24 and 0.50, respectively. The intraclass correlation coefficient (ICC) of the measurement of the acromial distance was 0.72 in relaxed position and 0.75 with the participant actively retracting both shoulders. The ICCs for the modified lateral scapular slide test varied between 0.63 and 0.58. Our results demonstrated that the modified lateral scapular slide test was not a reliable tool to assess scapular positioning in these participants. Our data indicated that scapular observation in the relaxed position and during unloaded abduction in the frontal plane was a reliable assessment tool. The reliability of the measurement of the distance between the posterior border of the acromion and the wall in healthy musicians was moderate.

  16. Inter-Rater Reliability of Cyclotorsion Measurements Using Fundus Photography.

    Science.gov (United States)

    Dysli, Muriel; Kanku, Madeleine; Traber, Ghislaine L

    2018-04-01

    The foveo-papillary angle (FPA) on fundus photographs is the accepted standard for the measurement of ocular cyclotorsion. We assessed the inter-rater reliability of this method in healthy subjects and in patients with trochlear nerve palsies. In this methodological study, fundus photographs of healthy subjects and of patients with trochlear nerve palsies were made with a fundus camera (Zeiss Fundus Camera FF 450 plus, Jena, Germany). Three independent observers measured the FPA on the fundus photographs of all subjects in synedra View (synedra View 16, Version 16.0.0.11, Innsbruck, Austria). One hundred and four eyes of 52 subjects (26 healthy controls and 26 patients) were assessed. The mean FPA of the healthy controls was 5.80 degrees (°) [± 0.44 standard error of the mean (SEM)] compared to 11.55° (± 0.80 SEM) for patients with trochlear nerve palsies. The inter-rater reliability of all measured FPAs showed an intraclass correlation coefficient (ICC) of 0.98 (95% CI 0.97 - 0.98). The inter-rater reliability of objective cyclotorsion measurements using fundus photographs was very high. Georg Thieme Verlag KG Stuttgart · New York.

  17. Reliability of radiographic measurements for acute distal radius fractures

    International Nuclear Information System (INIS)

    Watson, Narelle J.; Asadollahi, Saeed; Parrish, Frank; Ridgway, Jacqueline; Tran, Phong; Keating, Jennifer L.

    2016-01-01

    The management of distal radial fractures is guided by the interpretation of radiographic findings. The aim of this investigation was to determine the intra- and inter-observer reliability of eight traditionally reported anatomic radiographic parameters in adults with an acute distal radius fracture. Five observers participated. All were routinely involved in making treatment decisions based on distal radius fracture radiographs. Observers performed independent repeated measurements on 30 radiographs for eight anatomical parameters: dorsal shift (mm), intra-articular gap (mm), intra-articular step (mm), palmar tilt (degrees), radial angle (degrees), radial height (mm), radial shift (mm), ulnar variance (mm). Intraclass correlation coefficients (ICCs) and the magnitude of retest errors were calculated. Measurement reliability was summarised as high (ICC > 0.80), moderate (0.60–0.80) or low (<0.60). Intra-observer reliability was high for dorsal shift and palmar tilt; moderate for radial angle, radial height, ulnar variance and radial shift; and low for intra-articular gap and step. Inter-observer reliability was high for palmar tilt; moderate for dorsal shift, ulnar variance, radial angle and radial height; and low for radial shift, intra-articular gap and step. Error magnitude (95 % confidence interval) was within 1–2 mm for intra-articular gap and step, 2–4 mm for ulnar variance, 4–6 mm for radial shift, dorsal shift and radial height, and 6–8° for radial angle and palmar tilt. Based on previous reports of critical values for palmar tilt, ulnar variance and radial angle, error margins appear small enough for measurements to be useful in guiding treatment decisions. Our findings indicate that clinicians cannot reliably measure values ≤1 mm for intra-articular gap and step when interpreting radiographic parameters using the standardised methods investigated in this study. As a guide for treatment selection, palmar tilt, ulnar variance and radial angle

  18. Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.

    Science.gov (United States)

    Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti

    2017-06-28

    The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.

  19. A study of lip prints and its reliability as a forensic tool

    Science.gov (United States)

    Verma, Yogendra; Einstein, Arouquiaswamy; Gondhalekar, Rajesh; Verma, Anoop K.; George, Jiji; Chandra, Shaleen; Gupta, Shalini; Samadi, Fahad M.

    2015-01-01

    Introduction: Lip prints, like fingerprints, are unique to an individual and can be easily recorded. Therefore, we compared direct and indirect lip print patterns in males and females of different age groups, studied the inter- and intraobserver bias in recording the data, and observed any changes in the lip print patterns over a period of time, thereby, assessing the reliability of lip prints as a forensic tool. Materials and Methods: Fifty females and 50 males in the age group of 15 to 35 years were selected for the study. Lips with any deformity or scars were not included. Lip prints were registered by direct and indirect methods and transferred to a preformed registration sheet. Direct method of lip print registration was repeated after a six-month interval. All the recorded data were analyzed statistically. Results: The predominant patterns were vertical and branched. More females showed the branched pattern and males revealed an equal prevalence of vertical and reticular patterns. There was an interobserver agreement, which was 95%, and there was no change in the lip prints over time. Indirect registration of lip prints correlated with direct method prints. Conclusion: Lip prints can be used as a reliable forensic tool, considering the consistency of lip prints over time and the accurate correlation of indirect prints to direct prints. PMID:26668449

  20. Development of innovative inspection tools for higher reliability of PHWR fuel

    International Nuclear Information System (INIS)

    Kamalesh Kumar, B.; Viswanathan, B.; Laxminarayana, B.; Ganguly, C.

    2003-01-01

    'Full text:' Advent of Computer aided manufacturing systems has led to very high rate of production with greater reliability. The conventional inspection tools and systems, which are often manual based do not complement with output of highly automated production line. In order to overcome the deficiency, a strategic plan was developed for having automated inspection facility for PHWR fuel assembly line. Laser based systems with their inherently high accuracy and quick response times are a favorite for metrology purpose. Non-contact nature of laser-based measurement ensures minimal contamination, low wear and tear and good repeatability. So far two laser-based systems viz. Pellet density measurement systems and triangulation sensors have been developed. Laser based fuel pellet inspection system and PHWR fuel bundle metric station are under development. Machine vision-based systems have been developed to overcome certain limitations when inspection has to be carried out on such a large scale manually. These deficiencies arise from limitations of resolution, accessibility, fatigue and absence of quantification ability. These problems get further compounded in inspection of fuel components because of their relatively small sizes, close tolerances required and the reflective surfaces. PC based vision system has been developed for inspecting components and fuel assemblies. The paper would touch upon the details of the various laser systems and vision systems that have been indigenously developed for PHWR Fuel Metrology and their impact on the assembly production line. (author)

  1. Semi-structured interview is a reliable and feasible tool for selection of doctors for general practice specialist training.

    Science.gov (United States)

    Isaksen, Jesper Hesselbjerg; Hertel, Niels Thomas; Kjær, Niels Kristian

    2013-09-01

    In order to optimise the selection process for admission to specialist training in family medicine, we developed a new design for structured applications and selection interviews. The design contains semi-structured interviews, which combine individualised elements from the applications with standardised behaviour-based questions. This paper describes the design of the tool, and offers reflections concerning its acceptability, reliability and feasibility. We used a combined quantitative and qualitative evaluation method. Ratings obtained by the applicants in two selection rounds were analysed for reliability and generalisability using the GENOVA programme. Applicants and assessors were randomly selected for individual semi-structured in-depth interviews. The qualitative data were analysed in accordance with the grounded theory method. Quantitative analysis yielded a high Cronbach's alpha of 0.97 for the first round and 0.90 for the second round, and a G coefficient of the first round of 0.74 and of the second round of 0.40. Qualitative analysis demonstrated high acceptability and fairness and it improved the assessors' judgment. Applicants reported concerns about loss of personality and some anxiety. The applicants' ability to reflect on their competences was important. The developed selection tool demonstrated an acceptable level of reliability, but only moderate generalisability. The users found that the tool provided a high degree of acceptability; it is a feasible and useful tool for -selection of doctors for specialist training if combined with work-based assessment. Studies on the benefits and drawbacks of this tool compared with other selection models are relevant. not relevant. not relevant.

  2. Systematic evaluation of the teaching qualities of Obstetrics and Gynecology faculty: reliability and validity of the SETQ tools.

    Directory of Open Access Journals (Sweden)

    Renée van der Leeuw

    Full Text Available BACKGROUND: The importance of effective clinical teaching for the quality of future patient care is globally understood. Due to recent changes in graduate medical education, new tools are needed to provide faculty with reliable and individualized feedback on their teaching qualities. This study validates two instruments underlying the System for Evaluation of Teaching Qualities (SETQ aimed at measuring and improving the teaching qualities of obstetrics and gynecology faculty. METHODS AND FINDINGS: This cross-sectional multi-center questionnaire study was set in seven general teaching hospitals and two academic medical centers in the Netherlands. Seventy-seven residents and 114 faculty were invited to complete the SETQ instruments in the duration of one month from September 2008 to September 2009. To assess reliability and validity of the instruments, we used exploratory factor analysis, inter-item correlation, reliability coefficient alpha and inter-scale correlations. We also compared composite scales from factor analysis to global ratings. Finally, the number of residents' evaluations needed per faculty for reliable assessments was calculated. A total of 613 evaluations were completed by 66 residents (85.7% response rate. 99 faculty (86.8% response rate participated in self-evaluation. Factor analysis yielded five scales with high reliability (Cronbach's alpha for residents' and faculty: learning climate (0.86 and 0.75, professional attitude (0.89 and 0.81, communication of learning goals (0.89 and 0.82, evaluation of residents (0.87 and 0.79 and feedback (0.87 and 0.86. Item-total, inter-scale and scale-global rating correlation coefficients were significant (P<0.01. Four to six residents' evaluations are needed per faculty (reliability coefficient 0.60-0.80. CONCLUSIONS: Both SETQ instruments were found reliable and valid for evaluating teaching qualities of obstetrics and gynecology faculty. Future research should examine improvement of

  3. Measurement-based reliability/performability models

    Science.gov (United States)

    Hsueh, Mei-Chen

    1987-01-01

    Measurement-based models based on real error-data collected on a multiprocessor system are described. Model development from the raw error-data to the estimation of cumulative reward is also described. A workload/reliability model is developed based on low-level error and resource usage data collected on an IBM 3081 system during its normal operation in order to evaluate the resource usage/error/recovery process in a large mainframe system. Thus, both normal and erroneous behavior of the system are modeled. The results provide an understanding of the different types of errors and recovery processes. The measured data show that the holding times in key operational and error states are not simple exponentials and that a semi-Markov process is necessary to model the system behavior. A sensitivity analysis is performed to investigate the significance of using a semi-Markov process, as opposed to a Markov process, to model the measured system.

  4. Reliability of Patient-Led Screening with the Malnutrition Screening Tool: Agreement between Patient and Health Care Professional Scores in the Cancer Care Ambulatory Setting.

    Science.gov (United States)

    Di Bella, Alexandra; Blake, Claire; Young, Adrienne; Pelecanos, Anita; Brown, Teresa

    2018-02-01

    The prevalence of malnutrition in patients with cancer is reported as high as 60% to 80%, and malnutrition is associated with lower survival, reduced response to treatment, and poorer functional status. The Malnutrition Screening Tool (MST) is a validated tool when administered by health care professionals; however, it has not been evaluated for patient-led screening. This study aims to assess the reliability of patient-led MST screening through assessment of inter-rater reliability between patient-led and dietitian-researcher-led screening and intra-rater reliability between an initial and a repeat patient screening. This cross-sectional study included 208 adults attending ambulatory cancer care services in a metropolitan teaching hospital in Queensland, Australia, in October 2016 (n=160 inter-rater reliability; n=48 intra-rater reliability measured in a separate sample). Primary outcome measures were MST risk categories (MST 0-1: not at risk, MST ≥2: at risk) as determined by screening completed by patients and a dietitian-researcher, patient test-retest screening, and patient acceptability. Percent and chance-corrected agreement (Cohen's kappa coefficient, κ) were used to determine agreement between patient-MST and dietitian-MST (inter-rater reliability) and MST completed by patient on admission to unit (patient-MSTA) and MST completed by patient 1 to 3 hours after completion of initial MST (patient-MSTB) (intra-rater reliability). High inter-rater reliability and intra-rater reliability were observed. Agreement between patient-MST and dietitian-MST was 96%, with "almost perfect" chance-adjusted agreement (κ=0.92, 95% CI 0.84 to 0.97). Agreement between repeated patient-MSTA and patient-MSTB was 94%, with "almost perfect" chance-adjusted agreement (κ=0.88, 95% CI 0.71 to 1.00). Based on dietitian-MST, 33% (n=53) of patients were identified as being at risk for malnutrition, and 40% of these reported not seeing a dietitian. Of 156 patients who provided

  5. Reliability and Validity of the Korean Cancer Pain Assessment Tool (KCPAT)

    Science.gov (United States)

    Kim, Jeong A; Lee, Juneyoung; Park, Jeanno; Lee, Myung Ah; Yeom, Chang Hwan; Jang, Se Kwon; Yoon, Duck Mi; Kim, Jun Suk

    2005-01-01

    The Korean Cancer Pain Assessment Tool (KCPAT), which was developed in 2003, consists of questions concerning the location of pain, the nature of pain, the present pain intensity, the symptoms associated with the pain, and psychosocial/spiritual pain assessments. This study was carried out to evaluate the reliability and validity of the KCPAT. A stratified, proportional-quota, clustered, systematic sampling procedure was used. The study population (903 cancer patients) was 1% of the target population (90,252 cancer patients). A total of 314 (34.8%) questionnaires were collected. The results showed that the average pain score (5 point on Likert scale) according to the cancer type and the at-present average pain score (VAS, 0-10) were correlated (r=0.56, p<0.0001), and showed moderate agreement (kappa=0.364). The mean satisfaction score was 3.8 (1-5). The average time to complete the questionnaire was 8.9 min. In conclusion, the KCPAT is a reliable and valid instrument for assessing cancer pain in Koreans. PMID:16224166

  6. Nanoscale deformation measurements for reliability assessment of material interfaces

    Science.gov (United States)

    Keller, Jürgen; Gollhardt, Astrid; Vogel, Dietmar; Michel, Bernd

    2006-03-01

    With the development and application of micro/nano electronic mechanical systems (MEMS, NEMS) for a variety of market segments new reliability issues will arise. The understanding of material interfaces is the key for a successful design for reliability of MEMS/NEMS and sensor systems. Furthermore in the field of BIOMEMS newly developed advanced materials and well known engineering materials are combined despite of fully developed reliability concepts for such devices and components. In addition the increasing interface-to volume ratio in highly integrated systems and nanoparticle filled materials are challenges for experimental reliability evaluation. New strategies for reliability assessment on the submicron scale are essential to fulfil the needs of future devices. In this paper a nanoscale resolution experimental method for the measurement of thermo-mechanical deformation at material interfaces is introduced. The determination of displacement fields is based on scanning probe microscopy (SPM) data. In-situ SPM scans of the analyzed object (i.e. material interface) are carried out at different thermo-mechanical load states. The obtained images are compared by grayscale cross correlation algorithms. This allows the tracking of local image patterns of the analyzed surface structure. The measurement results are full-field displacement fields with nanometer resolution. With the obtained data the mixed mode type of loading at material interfaces can be analyzed with highest resolution for future needs in micro system and nanotechnology.

  7. Reliability and validity of a scale to measure consumer attitudes regarding the private food safety certification of restaurants.

    Science.gov (United States)

    Uggioni, Paula Lazzarin; Salay, Elisabete

    2012-04-01

    Validated and reliable instruments for measuring consumer attitudes regarding food quality certifications are lacking, but the measurement of consumer attitude could be an important tool for understanding consumer behavior. Thus the objective of this study was to develop an instrument for measuring consumer attitudes regarding private food safety certifications for commercial restaurants. To this end, the following steps were carried out: development of the interview items; complete pilot testing; item analyses (influence of social desirability and total-item correlation); reliability test (internal consistency and test-retest); and validity assessment (content and discriminative validity and exploratory and confirmatory factor analysis). The subjects, all over the age of 18 and drawn from six non-probabilistic samples (n=7-350) in the city of Campinas, Brazil, were all subjected to an interview. The final scale included 24 items and had a Cronbach's alpha coefficient of 0.79 and a content validation coefficient of 0.99, both within acceptable limits. The confirmatory factor analysis validated a model with five factors and the final instrument discriminated reasonably well between the groups and showed satisfactory reproducibility (r=0.955). Furthermore, the scale validity and reliability were satisfactory, suggesting it could also be applied to future studies. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Validation and Reliability of a Smartphone Application for the International Prostate Symptom Score Questionnaire: A Randomized Repeated Measures Crossover Study

    Science.gov (United States)

    Shim, Sung Ryul; Sun, Hwa Yeon; Ko, Young Myoung; Chun, Dong-Il; Yang, Won Jae

    2014-01-01

    Background Smartphone-based assessment may be a useful diagnostic and monitoring tool for patients. There have been many attempts to create a smartphone diagnostic tool for clinical use in various medical fields but few have demonstrated scientific validity. Objective The purpose of this study was to develop a smartphone application of the International Prostate Symptom Score (IPSS) and to demonstrate its validity and reliability. Methods From June 2012 to May 2013, a total of 1581 male participants (≥40 years old), with or without lower urinary tract symptoms (LUTS), visited our urology clinic via the health improvement center at Soonchunhyang University Hospital (Republic of Korea) and were enrolled in this study. A randomized repeated measures crossover design was employed using a smartphone application of the IPSS and the conventional paper form of the IPSS. Paired t test under a hypothesis of non-inferior trial was conducted. For the reliability test, the intraclass correlation coefficient (ICC) was measured. Results The total score of the IPSS (P=.289) and each item of the IPSS (P=.157-1.000) showed no differences between the paper version and the smartphone version of the IPSS. The mild, moderate, and severe LUTS groups showed no differences between the two versions of the IPSS. A significant correlation was noted in the total group (ICC=.935, Psmartphones could participate. Conclusions The validity and reliability of the smartphone application version were comparable to the conventional paper version of the IPSS. The smartphone application of the IPSS could be an effective method for measuring lower urinary tract symptoms. PMID:24513507

  9. Validity and reliability of Preschool Language Scale 4 for measuring language development in children 48-59 months of age

    Directory of Open Access Journals (Sweden)

    Nuryani Sidarta

    2016-04-01

    Full Text Available Prevalence rates for speech and language delay have been reported across wide ranges. Speech and language delay affects 5% to 8% of preschool children, often persisting into the school years.  A cross-sectional study was conducted in 208 children aged 48-59 months to determine the validity and reliability of the Indonesian edition of the Preschool Language Scale version 4 (PLS4 as a screening tool for the identification of language development disorders. Construct validity was examined by using Pearson correlation coefficient. Internal consistency was tested and repeated measurements were taken to establish the stability coefficient and intraclass correlation coefficients (ICC for test-retest reliability. For construct validity, the Pearson correlation coefficient ranged from 0.151-0.526, indicating that all questions in this instrument were valid for measuring auditory comprehension (AC and expressive communication skills (EC. Cronbach’s alpha level ranged from 0.81-0.95 with standard error of measurement (SEM ranging from 3.1-3.3. Stability coefficients ranged from 0.98-.0.99 with ICC coefficient ranging from 0.97-0.99 both of which showed an excellent reliability. This study found that PLS-4 is a valid and reliable instrument. It is easy to handle and can be recommended for assessing language development in children aged 48-59 months.

  10. Ensuring Structural Integrity through Reliable Residual Stress Measurement: From Crystals to Crankshafts

    International Nuclear Information System (INIS)

    Edwards, Lyndon

    2005-01-01

    Full text: The determination of accurate, reliable stresses is critical to many fields of engineering and, in particular, the structural integrity and hence, safety, of many systems. Neutron stress measurement is a non-destructive technique that uniquely provides insights into stress fields deep within components and structures. As such, it has become an increasingly important tool within the engineering community leading to improved manufacturing processes to reduce stress and distortion as well as to the definition of more precise structural integrity lifting procedures. This talk describes the current state of the art and identifies the key opportunities for improved structural integrity provided by the 2nd generation dedicated engineering stress diffractometers currently being designed and commissioned world-wide. Examples are provided covering a range of industrially relevant problems from the fields. (author)

  11. Measuring patient-provider communication skills in Rwanda: Selection, adaptation and assessment of psychometric properties of the Communication Assessment Tool.

    Science.gov (United States)

    Cubaka, Vincent Kalumire; Schriver, Michael; Vedsted, Peter; Makoul, Gregory; Kallestrup, Per

    2018-04-23

    To identify, adapt and validate a measure for providers' communication and interpersonal skills in Rwanda. After selection, translation and piloting of the measure, structural validity, test-retest reliability, and differential item functioning were assessed. Identification and adaptation: The 14-item Communication Assessment Tool (CAT) was selected and adapted. Content validation found all items highly relevant in the local context except two, which were retained upon understanding the reasoning applied by patients. Eleven providers and 291 patients were involved in the field-testing. Confirmatory factor analysis showed a good fit for the original one factor model. Test-retest reliability assessment revealed a mean quadratic weighted Kappa = 0.81 (range: 0.69-0.89, N = 57). The average proportion of excellent scores was 15.7% (SD: 24.7, range: 9.9-21.8%, N = 180). Differential item functioning was not observed except for item 1, which focuses on greetings, for age groups (p = 0.02, N = 180). The Kinyarwanda version of CAT (K-CAT) is a reliable and valid patient-reported measure of providers' communication and interpersonal skills. K-CAT was validated on nurses and its use on other types of providers may require further validation. K-CAT is expected to be a valuable feedback tool for providers in practice and in training. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Is linear distance measured by panoramic radiography reliable?

    International Nuclear Information System (INIS)

    Nishikawa, Keiichi; Wakoh, Mamoru; Sano, Tsukasa; Suehiro, Atsushi; Sekine, Hideshi; Kousuge, Yuuji

    2010-01-01

    The objective of this study was to re-examine the reliability of distance measurements on clinical panoramic radiographs by comparing them with computed tomography (CT) images, from which the most accurate distance measurement is possible. Twenty pairs of images from patients examined both with panoramic radiography and CT for dental implant treatment planning in the premolar and molar regions of the mandible were used. The vertical linear distance between the alveolar crest and the closest mandibular canal was measured by three experienced oral radiologists on both images. The distances measured on panoramic radiographs were corrected for the magnification factor at the focal plane. Double-oblique cross-sectional images were used for CT. Pearson's correlation coefficient was calculated between distances obtained from both images. The paired t test was performed for statistical comparison. Error levels with the panoramic radiograph versus the CT image were also calculated. Pearson's correlation coefficient showed a significant strong linear correlation (R=0.90; p<0.01). However, the corrected value of distance measured on panoramic radiographs tended to be too small, and a significant difference was observed (p<0.05). The error level was approximately 10% (9.6±7.3%). Distance measurement on clinical panoramic radiographs is less reliable than CT images and cannot be recommended. (author)

  13. Development of a Tool to Measure Youths' Food Allergy Management Facilitators and Barriers.

    Science.gov (United States)

    Herbert, Linda Jones; Lin, Adora; Matsui, Elizabeth; Wood, Robert A; Sharma, Hemant

    2016-04-01

    This study's aims are to identify factors related to allergen avoidance and epinephrine carriage among youth with food allergy, develop a tool to measure food allergy management facilitators and barriers, and investigate its initial reliability and validity.  The Food Allergy Management Perceptions Questionnaire (FAMPQ) was developed based on focus groups with 19 adolescents and young adults with food allergy. Additional youth with food allergy (N = 92; ages: 13-21 years) completed food allergy clinical history and management questionnaires and the FAMPQ.  Internal reliability estimates for the FAMPQ Facilitators and Barriers subscales were acceptable to good. Youth who were adherent to allergen avoidance and epinephrine carriage had higher Facilitator scores. Poor adherence was more likely among youth with higher Barrier scores.  Initial FAMPQ reliability and validity is promising. Additional research is needed to develop FAMPQ clinical guidelines. © The Author 2015. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Reliability and Inequality Measures for the Weimal Distribution ...

    African Journals Online (AJOL)

    ). This article aimed at discussing both reliability and inequality measures from the Weimal distribution. The work has derived and discussed theoretically, expressions for the survival and hazard function of the Weimal distribution. The ordinary ...

  15. Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion.

    Science.gov (United States)

    Charlton, Paula C; Mentiplay, Benjamin F; Pua, Yong-Hao; Clark, Ross A

    2015-05-01

    Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Intra-tester reliability with concurrent validity. Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. The Smartphone demonstrated good to excellent reliability (ICCs>0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC=0.63-0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs>0.88) except one, which displayed moderate to good validity (ICC=0.71). Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  16. Damage preventing measures for wind turbines. Phase 1- Reliability data

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson, Fredrik; Eriksson, Emil; Dahlberg, Magnus

    2010-08-15

    The state of existing reliability and failure data in the public sources has been investigated. The prime goal has been to evaluate the data's usefulness for developing damage preventing measures. Some publicly available databases exist, and the data has been presented in several papers in the literature. The results from the investigation can seem quite negative. Detailed data are lacking and the level of detailed reporting has even been decreasing in recent years. Information on the impact of load condition on failures, which is an important question, are lacking throughout in the statistics. Some components dominate the failure statistics. These are for example the gearboxes, where failures lead to long down times. Failures of the electrical system lead to considerably shorter down times but the failure rate is much higher. Severe rotor failures seem to be rare, but they occur and the consequences can be dramatic. Operators and insurance companies are demanding improved insight in damage collection, maintenance and overall damage preventing measures. Closer cooperation with these parties could be a fruitful way of gathering more useful data. Improvements for future databases are suggested. A structure for damage collection is proposed. Comparing experience of damage preventing measures from other industries, knowledge about the nature of the damage mechanism and current practice in the wind industry will be an important tool in the evaluation of different damage preventing measures. This will be done in the following phases of this project

  17. Is Nottingham Health Profile a reliable tool to measure quality of life of Filipinos with chronic kidney diseases undergoing hemodialysis.

    Science.gov (United States)

    Chuku, Chika Lawson; Valdez, Josephine R; Ajonuma, Louis Chukwuemeka

    2010-12-01

    The quality of life (QOL) of hemodialysis patients is often compromised and many tools have been developed to assess the health-related QOL of chronic kidney disease (CKD) patients undergoing hemodialysis. However, no such tool is currently in use in the Philippines. The objective of this study is to determine if Nottingham Health Profile (NHP) can be a useful tool in the Philippines. Eighty patients undergoing hemodialysis in the dialysis unit of our hospital were enrolled for this study. Sixty-nine patients completed the study. Comparative analysis revealed significant difference in social isolation with favorable result for the Filipino patients. Other measures correlate well although with differences that were not statistically significant. NHP can be successfully applied as a standard QOL tool in the Philippines. However, it should be translated into Filipino to avoid language difficulty. NHP may be recommended for QOL determination in other developing countries.

  18. Reliable and valid assessment of Lichtenstein hernia repair skills

    DEFF Research Database (Denmark)

    Carlsen, C G; Lindorff Larsen, Karen; Funch-Jensen, P

    2014-01-01

    PURPOSE: Lichtenstein hernia repair is a common surgical procedure and one of the first procedures performed by a surgical trainee. However, formal assessment tools developed for this procedure are few and sparsely validated. The aim of this study was to determine the reliability and validity...... of an assessment tool designed to measure surgical skills in Lichtenstein hernia repair. METHODS: Key issues were identified through a focus group interview. On this basis, an assessment tool with eight items was designed. Ten surgeons and surgical trainees were video recorded while performing Lichtenstein hernia...... a significant difference between the three groups which indicates construct validity, p skills can be assessed blindly by a single rater in a reliable and valid fashion with the new procedure-specific assessment tool. We recommend this tool for future assessment...

  19. Development, reliability and use of a food environment assessment tool in supermarkets of four neighbourhoods in Montréal, Canada.

    Science.gov (United States)

    Jalbert-Arsenault, Élise; Robitaille, Éric; Paquette, Marie-Claude

    2017-09-01

    The food environment is a promising arena in which to influence people's dietary habits. This study aimed to develop a comprehensive food environment assessment tool for businesses and characterize the food environment of a low-tomedium income area of Montréal, Canada. We developed a tool, Mesure de l'environnement alimentaire du consommateur dans les supermarchés (MEAC-S), and tested it for reliability. We used the MEAC-S to assess the consumer food environment of 17 supermarkets in four neighbourhoods of Montréal. We measured the shelf length, variety, price, display counts and in-store positions of fruits and vegetables (FV) and ultra-processed food products (UPFPs). We also assessed fresh FV for quality. Store size was estimated using the total measured shelf length for all food categories. We conducted Spearman correlations between these indicators of the food environment. Reliability analyses revealed satisfactory results for most indicators. Characterization of the food environment revealed high variability in shelf length, variety and price of FV between supermarkets and suggested a disproportionate promotion of UPFPs. Display counts of UPFPs outside their normal display location ranged from 7 to 26, and they occupied 8 to 33 strategic in-store positions, whereas the number of display counts of fresh FV outside their normal display location exceeded 1 in only 2 of the 17 stores surveyed, and they occupied a maximum of 2 strategic in-store positions per supermarket. Price of UPFPs was inversely associated with their prominence (p environment between supermarkets and underscores the importance of measuring in-store characteristics to adequately picture the consumer food environment.

  20. Reliability measures in item response theory: manifest versus latent correlation functions.

    Science.gov (United States)

    Milanzi, Elasma; Molenberghs, Geert; Alonso, Ariel; Verbeke, Geert; De Boeck, Paul

    2015-02-01

    For item response theory (IRT) models, which belong to the class of generalized linear or non-linear mixed models, reliability at the scale of observed scores (i.e., manifest correlation) is more difficult to calculate than latent correlation based reliability, but usually of greater scientific interest. This is not least because it cannot be calculated explicitly when the logit link is used in conjunction with normal random effects. As such, approximations such as Fisher's information coefficient, Cronbach's α, or the latent correlation are calculated, allegedly because it is easy to do so. Cronbach's α has well-known and serious drawbacks, Fisher's information is not meaningful under certain circumstances, and there is an important but often overlooked difference between latent and manifest correlations. Here, manifest correlation refers to correlation between observed scores, while latent correlation refers to correlation between scores at the latent (e.g., logit or probit) scale. Thus, using one in place of the other can lead to erroneous conclusions. Taylor series based reliability measures, which are based on manifest correlation functions, are derived and a careful comparison of reliability measures based on latent correlations, Fisher's information, and exact reliability is carried out. The latent correlations are virtually always considerably higher than their manifest counterparts, Fisher's information measure shows no coherent behaviour (it is even negative in some cases), while the newly introduced Taylor series based approximations reflect the exact reliability very closely. Comparisons among the various types of correlations, for various IRT models, are made using algebraic expressions, Monte Carlo simulations, and data analysis. Given the light computational burden and the performance of Taylor series based reliability measures, their use is recommended. © 2014 The British Psychological Society.

  1. Reliability measures of functional magnetic resonance imaging in a longitudinal evaluation of mild cognitive impairment.

    Science.gov (United States)

    Zanto, Theodore P; Pa, Judy; Gazzaley, Adam

    2014-01-01

    As the aging population grows, it has become increasingly important to carefully characterize amnestic mild cognitive impairment (aMCI), a preclinical stage of Alzheimer's disease (AD). Functional magnetic resonance imaging (fMRI) is a valuable tool for monitoring disease progression in selectively vulnerable brain regions associated with AD neuropathology. However, the reliability of fMRI data in longitudinal studies of older adults with aMCI is largely unexplored. To address this, aMCI participants completed two visual working tasks, a Delayed-Recognition task and a One-Back task, on three separate scanning sessions over a three-month period. Test-retest reliability of the fMRI blood oxygen level dependent (BOLD) activity was assessed using an intraclass correlation (ICC) analysis approach. Results indicated that brain regions engaged during the task displayed greater reliability across sessions compared to regions that were not utilized by the task. During task-engagement, differential reliability scores were observed across the brain such that the frontal lobe, medial temporal lobe, and subcortical structures exhibited fair to moderate reliability (ICC=0.3-0.6), while temporal, parietal, and occipital regions exhibited moderate to good reliability (ICC=0.4-0.7). Additionally, reliability across brain regions was more stable when three fMRI sessions were used in the ICC calculation relative to two fMRI sessions. In conclusion, the fMRI BOLD signal is reliable across scanning sessions in this population and thus a useful tool for tracking longitudinal change in observational and interventional studies in aMCI. © 2013.

  2. Reliability of Rehabilitative Ultrasonography to Measure Transverse Abdominis and Multifidus Muscle Dimensions

    International Nuclear Information System (INIS)

    Nabavi, Narjes; Mosallanezhad, Zahra; Haghighatkhah, Hamid Reza; Mohseni Bandpeid, Mohammad Ali

    2014-01-01

    Lumbar paraspinal muscles play an important role in providing both mobility and stability during dynamic tasks. Among paraspinal muscles, transverse abdominis and lumbar multifidus have been of particular interest as active stabilizers of the lumbar spine. These muscles may become dysfunctional in chronic low back pain (CLBP). Low back injury can result in muscle inhibition and control loss that cannot recover spontaneously, and specific exercises are required to stimulate their recovery. The purpose of this study was to test the reliability of ultrasonography to measure muscle dimensions and to present a reliable method for measuring transverse abdominis and lumbar multifidus as stabilizing muscles of the lumbar spine. Fifteen healthy participants (18-55 year olds) were evaluated by a radiologist using ultrasonography (ES500) with two probes (50mm linear 7.5 MHZ and 70 mm curvilinear 3.5 MHz). The muscle thickness of transverse abdominis and the anterior-posterior diameter and cross sectional area of the LMF were measured. To determine within and between days reliabilities, second and third measurements were repeated with half an hour and one week intervals, respectively. Intraclass correlation coefficient for left and right showed good to high reliability for the cross sectional area of lumbar multifidi (0.74 and 0.88, respectively) as well as the anterior-posterior dimensions of lumbar multifidi (0.89 and 0.91, respectively) and transverse abdomini thickness (0.73 and 0.85, respectively). Rehabilitative ultrasonography is a reliable and non-invasive instrument to measure muscle thickness. The method used in this study is a reliable way to measure lumbar stabilizing muscles

  3. Improved radiograph measurement inter-observer reliability by use of statistical shape models

    Energy Technology Data Exchange (ETDEWEB)

    Pegg, E.C., E-mail: elise.pegg@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Mellon, S.J., E-mail: stephen.mellon@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Salmon, G. [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Alvand, A., E-mail: abtin.alvand@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Pandit, H., E-mail: hemant.pandit@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Murray, D.W., E-mail: david.murray@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Gill, H.S., E-mail: richie.gill@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom)

    2012-10-15

    Pre- and post-operative radiographs of patients undergoing joint arthroplasty are often examined for a variety of purposes including preoperative planning and patient assessment. This work examines the feasibility of using active shape models (ASM) to semi-automate measurements from post-operative radiographs for the specific case of the Oxford™ Unicompartmental Knee. Measurements of the proximal tibia and the position of the tibial tray were made using the ASM model and manually. Data were obtained by four observers and one observer took four sets of measurements to allow assessment of the inter- and intra-observer reliability, respectively. The parameters measured were the tibial tray angle, the tray overhang, the tray size, the sagittal cut position, the resection level and the tibial width. Results demonstrated improved reliability (average of 27% and 11.2% increase for intra- and inter-reliability, respectively) and equivalent accuracy (p > 0.05 for compared data values) for all of the measurements using the ASM model, with the exception of the tray overhang (p = 0.0001). Less time (15 s) was required to take measurements using the ASM model compared with manual measurements, which was significant. These encouraging results indicate that semi-automated measurement techniques could improve the reliability of radiographic measurements.

  4. Improved radiograph measurement inter-observer reliability by use of statistical shape models

    International Nuclear Information System (INIS)

    Pegg, E.C.; Mellon, S.J.; Salmon, G.; Alvand, A.; Pandit, H.; Murray, D.W.; Gill, H.S.

    2012-01-01

    Pre- and post-operative radiographs of patients undergoing joint arthroplasty are often examined for a variety of purposes including preoperative planning and patient assessment. This work examines the feasibility of using active shape models (ASM) to semi-automate measurements from post-operative radiographs for the specific case of the Oxford™ Unicompartmental Knee. Measurements of the proximal tibia and the position of the tibial tray were made using the ASM model and manually. Data were obtained by four observers and one observer took four sets of measurements to allow assessment of the inter- and intra-observer reliability, respectively. The parameters measured were the tibial tray angle, the tray overhang, the tray size, the sagittal cut position, the resection level and the tibial width. Results demonstrated improved reliability (average of 27% and 11.2% increase for intra- and inter-reliability, respectively) and equivalent accuracy (p > 0.05 for compared data values) for all of the measurements using the ASM model, with the exception of the tray overhang (p = 0.0001). Less time (15 s) was required to take measurements using the ASM model compared with manual measurements, which was significant. These encouraging results indicate that semi-automated measurement techniques could improve the reliability of radiographic measurements

  5. Measuring Light with Useful Tools

    Science.gov (United States)

    Peek, Gina; Hebert, Paulette; Frazier, Robert Scott; Knag, Mihyun

    2013-01-01

    Lighting, a necessary part of our home and work environment, is often considered as an afterthought. This article describes tools that Extension educators (Agriculture, Family and Consumer Sciences, and 4-H) can use to measure light levels. 4-H youth may also participate. These tools include light meters and Illuminating Engineering Society (IES)…

  6. Improving accuracy and reliability of 186-keV measurements for unattended enrichment monitoring

    International Nuclear Information System (INIS)

    Ianakiev, Kiril D.; Boyer, Brian D.; Swinhoe, Martyn T.; Moss, Cal E.; Goda, Joetta M.; Favalli, Andrea; Lombardi, Marcie; Paffet, Mark T.; Hill, Thomas R.; MacArthur, Duncan W.; Smith, Morag K.

    2010-01-01

    Improving the quality of safeguards measurements at Gas Centrifuge Enrichment Plants (GCEPs), whilst reducing the inspection effort, is an important objective given the number of existing and new plants that need to be safeguarded. A useful tool in many safeguards approaches is the on-line monitoring of enrichment in process pipes. One aspect of this measurement is a simple, reliable and precise passive measurement of the 186-keV line from 235 U. (The other information required is the amount of gas in the pipe. This can be obtained by transmission measurements or pressure measurements). In this paper we describe our research efforts towards such a passive measurement system. The system includes redundant measurements of the 186-keV line from the gas and separately from the wall deposits. The design also includes measures to reduce the effect of the potentially important background. Such an approach would practically eliminate false alarms and can maintain the operation of the system even with a hardware malfunction in one of the channels. The work involves Monte Carlo modeling and the construction of a proof-of-principle prototype. We will carry out experimental tests with UF 6 gas in pipes with and without deposits in order to demonstrate the deposit correction.

  7. Measuring Implicit European and Mediterranean Landscape Identity: A Tool Proposal

    Science.gov (United States)

    Fornara, Ferdinando; Dentale, Francesco; Troffa, Renato; Piras, Simona

    2016-01-01

    This study presents a tool – the Landscape Identity Implicit Association Test (LI-IAT) – devoted to measure the implicit identification with European and Mediterranean landscapes. To this aim, a series of prototypical landscapes was selected as stimulus, following an accurate multi-step procedure. Participants (N = 174), recruited in two Italian cities, performed two LI-IATs devoted to assess their identification with European vs. Not-European and Mediterranean vs. Not-Mediterranean prototypical landscapes. Psychometric properties and criterion validity of these measures were investigated. Two self-report measures, assessing, respectively, European and Mediterranean place identity and pleasantness of the target landscapes, were also administered. Results showed: (1) an adequate level of internal consistency for both LI-IATs; (2) a higher identification with European and Mediterranean landscapes than, respectively, with Not-European and Not-Mediterranean ones; and (3) a significant positive relationship between the European and Mediterranean LI-IATs and the corresponding place identity scores, also when pleasantness of landscapes was controlled for. Overall, these findings provide a first evidence supporting the reliability and criterion validity of the European and Mediterranean LI-IATs. PMID:27642284

  8. Reliability calculations

    International Nuclear Information System (INIS)

    Petersen, K.E.

    1986-03-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very complex systems. In order to increase the applicability of the programs variance reduction techniques can be applied to speed up the calculation process. Variance reduction techniques have been studied and procedures for implementation of importance sampling are suggested. (author)

  9. Measurement Variability of Vertical Scanning Interferometry Tool Used for Orbiter Window Defect Assessment

    Science.gov (United States)

    Padula, Santo, II

    2009-01-01

    The ability to sufficiently measure orbiter window defects to allow for window recertification has been an ongoing challenge for the orbiter vehicle program. The recent Columbia accident has forced even tighter constraints on the criteria that must be met in order to recertify windows for flight. As a result, new techniques are being investigated to improve the reliability, accuracy and resolution of the defect detection process. The methodology devised in this work, which is based on the utilization of a vertical scanning interferometric (VSI) tool, shows great promise for meeting the ever increasing requirements for defect detection. This methodology has the potential of a 10-100 fold greater resolution of the true defect depth than can be obtained from the currently employed micrometer based methodology. An added benefit is that it also produces a digital elevation map of the defect, thereby providing information about the defect morphology which can be utilized to ascertain the type of debris that induced the damage. However, in order to successfully implement such a tool, a greater understanding of the resolution capability and measurement repeatability must be obtained. This work focused on assessing the variability of the VSI-based measurement methodology and revealed that the VSI measurement tool was more repeatable and more precise than the current micrometer based approach, even in situations where operator variation could affect the measurement. The analysis also showed that the VSI technique was relatively insensitive to the hardware and software settings employed, making the technique extremely robust and desirable

  10. Reliability-guided digital image correlation for image deformation measurement

    International Nuclear Information System (INIS)

    Pan Bing

    2009-01-01

    A universally applicable reliability-guided digital image correlation (DIC) method is proposed for reliable image deformation measurement. The zero-mean normalized cross correlation (ZNCC) coefficient is used to identify the reliability of the point computed. The correlation calculation begins with a seed point and is then guided by the ZNCC coefficient. That means the neighbors of the point with the highest ZNCC coefficient in a queue for computed points will be processed first. Thus the calculation path is always along the most reliable direction, and possible error propagation of the conventional DIC method can be avoided. The proposed novel DIC method is universally applicable to the images with shadows, discontinuous areas, and deformation discontinuity. Two image pairs were used to evaluate the performance of the proposed technique, and the successful results clearly demonstrate its robustness and effectiveness

  11. The role of test-retest reliability in measuring individual and group differences in executive functioning.

    Science.gov (United States)

    Paap, Kenneth R; Sawi, Oliver

    2016-12-01

    Studies testing for individual or group differences in executive functioning can be compromised by unknown test-retest reliability. Test-retest reliabilities across an interval of about one week were obtained from performance in the antisaccade, flanker, Simon, and color-shape switching tasks. There is a general trade-off between the greater reliability of single mean RT measures, and the greater process purity of measures based on contrasts between mean RTs in two conditions. The individual differences in RT model recently developed by Miller and Ulrich was used to evaluate the trade-off. Test-retest reliability was statistically significant for 11 of the 12 measures, but was of moderate size, at best, for the difference scores. The test-retest reliabilities for the Simon and flanker interference scores were lower than those for switching costs. Standard practice evaluates the reliability of executive-functioning measures using split-half methods based on data obtained in a single day. Our test-retest measures of reliability are lower, especially for difference scores. These reliability measures must also take into account possible day effects that classical test theory assumes do not occur. Measures based on single mean RTs tend to have acceptable levels of reliability and convergent validity, but are "impure" measures of specific executive functions. The individual differences in RT model shows that the impurity problem is worse than typically assumed. However, the "purer" measures based on difference scores have low convergent validity that is partly caused by deficiencies in test-retest reliability. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. The Reliability of a Novel Mobile 3-dimensional Wound Measurement Device.

    Science.gov (United States)

    Anghel, Ersilia L; Kumar, Anagha; Bigham, Thomas E; Maselli, Kathryn M; Steinberg, John S; Evans, Karen K; Kim, Paul J; Attinger, Christopher E

    2016-11-01

    Objective assessment of wound dimensions is essential for tracking progression and determining treatment effectiveness. A reliability study was designed to establish intrarater and interrater reliability of a novel mobile 3-dimensional wound measurement (3DWM) device. Forty-five wounds were assessed by 2 raters using a 3DWM device to obtain length, width, area, depth, and volume measurements. Wounds were also measured manually, using a disposable ruler and digital planimetry. The intraclass correlation coefficient (ICC) was used to establish intrarater and interrater reliability. High levels of intrarater and interrater agreement were observed for area, length, and width; ICC = 0.998, 0.977, 0.955 and 0.999, 0.997, 0.995, respectively. Moderate levels of intrarater (ICC = 0.888) and interrater (ICC = 0.696) agreement were observed for volume. Lastly, depth yielded an intrarater ICC of 0.360 and an interrater ICC of 0.649. Measures from the 3DWM device were highly correlated with those obtained from scaled photography for length, width, and area (ρ = 0.997, 0.988, 0.997, P device yielded correlations of ρ = 0.990, 0.987, 0.996 with P device was found to be highly reliable for measuring wound areas for a range of wound sizes and types as compared to manual measurement and digital planimetry. The depth and therefore volume measurement using the 3DWM device was found to have a lower ICC, but volume ICC alone was moderate. Overall, this device offers a mobile option for objective wound measurement in the clinical setting.

  13. Reliability and Validity of Finger Strength and Endurance Measurements in Rock Climbing

    Science.gov (United States)

    Michailov, Michail Lubomirov; Baláš, Jirí; Tanev, Stoyan Kolev; Andonov, Hristo Stoyanov; Kodejška, Jan; Brown, Lee

    2018-01-01

    Purpose: An advanced system for the assessment of climbing-specific performance was developed and used to: (a) investigate the effect of arm fixation (AF) on construct validity evidence and reliability of climbing-specific finger-strength measurement; (b) assess reliability of finger-strength and endurance measurements; and (c) evaluate the…

  14. Electronic structure of BN-aromatics: Choice of reliable computational tools

    Science.gov (United States)

    Mazière, Audrey; Chrostowska, Anna; Darrigan, Clovis; Dargelos, Alain; Graciaa, Alain; Chermette, Henry

    2017-10-01

    The importance of having reliable calculation tools to interpret and predict the electronic properties of BN-aromatics is directly linked to the growing interest for these very promising new systems in the field of materials science, biomedical research, or energy sustainability. Ionization energy (IE) is one of the most important parameters to approach the electronic structure of molecules. It can be theoretically estimated, but in order to evaluate their persistence and propose the most reliable tools for the evaluation of different electronic properties of existent or only imagined BN-containing compounds, we took as reference experimental values of ionization energies provided by ultra-violet photoelectron spectroscopy (UV-PES) in gas phase—the only technique giving access to the energy levels of filled molecular orbitals. Thus, a set of 21 aromatic molecules containing B-N bonds and B-N-B patterns has been merged for a comparison between experimental IEs obtained by UV-PES and various theoretical approaches for their estimation. Time-Dependent Density Functional Theory (TD-DFT) methods using B3LYP and long-range corrected CAM-B3LYP functionals are used, combined with the Δ SCF approach, and compared with electron propagator theory such as outer valence Green's function (OVGF, P3) and symmetry adapted cluster-configuration interaction ab initio methods. Direct Kohn-Sham estimation and "corrected" Kohn-Sham estimation are also given. The deviation between experimental and theoretical values is computed for each molecule, and a statistical study is performed over the average and the root mean square for the whole set and sub-sets of molecules. It is shown that (i) Δ SCF+TDDFT(CAM-B3LYP), OVGF, and P3 are the most efficient way for a good agreement with UV-PES values, (ii) a CAM-B3LYP range-separated hybrid functional is significantly better than B3LYP for the purpose, especially for extended conjugated systems, and (iii) the "corrected" Kohn-Sham result is a

  15. Inter-device reliability of an automatic-scoring actigraph for measuring sleep in healthy adults

    Directory of Open Access Journals (Sweden)

    Matthew Driller

    2016-07-01

    Full Text Available Actigraphy has become a common method of measuring sleep due to its non-invasive, cost-effective nature. An actigraph (Readiband™ that utilizes automatic scoring algorithms has been used in the research, but is yet to be evaluated for its inter-device reliability. A total of 77 nights of sleep data from 11 healthy adult participants was collected while participants were concomitantly wearing two Readiband™ actigraphs attached together (ACT1 and ACT2. Sleep indices including total sleep time (TST, sleep latency (SL, sleep efficiency (SE%, wake after sleep onset (WASO, total time in bed (TTB, wake episodes per night (WE, sleep onset variance (SOV and wake variance (WV were assessed between the two devices using mean differences, 95% levels of agreement, intraclass correlation coefficients (ICC, typical error of measurement (TEM and coefficient of variation (CV% analysis. There were no significant differences between devices for any of the measured sleep variables (p>0.05. TST, SE, SL, TTB, SOV and WV all resulted in very high ICC's (>0.90, with WASO and WE resulting in high ICC's between devices (0.85 and 0.80, respectively. Mean differences of −2.1 and 0.2 min for TST and SL were associated with a low TEM between devices (9.5 and 3.8 min, respectively. SE resulted in a 0.3% mean difference between devices. The Readiband™ is a reliable tool for researchers using multiple devices of this brand in sleep studies to assess basic measures of sleep quality and quantity in healthy adult populations.

  16. Statistical Primer for Athletic Trainers: The Essentials of Understanding Measures of Reliability and Minimal Important Change.

    Science.gov (United States)

    Riemann, Bryan L; Lininger, Monica R

    2018-01-01

      To describe the concepts of measurement reliability and minimal important change.   All measurements have some magnitude of error. Because clinical practice involves measurement, clinicians need to understand measurement reliability. The reliability of an instrument is integral in determining if a change in patient status is meaningful.   Measurement reliability is the extent to which a test result is consistent and free of error. Three perspectives of reliability-relative reliability, systematic bias, and absolute reliability-are often reported. However, absolute reliability statistics, such as the minimal detectable difference, are most relevant to clinicians because they provide an expected error estimate. The minimal important difference is the smallest change in a treatment outcome that the patient would identify as important.   Clinicians should use absolute reliability characteristics, preferably the minimal detectable difference, to determine the extent of error around a patient's measurement. The minimal detectable difference, coupled with an appropriately estimated minimal important difference, can assist the practitioner in identifying clinically meaningful changes in patients.

  17. Systematic evaluation of the teaching qualities of Obstetrics and Gynecology faculty: reliability and validity of the SETQ tools.

    Science.gov (United States)

    van der Leeuw, Renée; Lombarts, Kiki; Heineman, Maas Jan; Arah, Onyebuchi

    2011-05-03

    The importance of effective clinical teaching for the quality of future patient care is globally understood. Due to recent changes in graduate medical education, new tools are needed to provide faculty with reliable and individualized feedback on their teaching qualities. This study validates two instruments underlying the System for Evaluation of Teaching Qualities (SETQ) aimed at measuring and improving the teaching qualities of obstetrics and gynecology faculty. This cross-sectional multi-center questionnaire study was set in seven general teaching hospitals and two academic medical centers in the Netherlands. Seventy-seven residents and 114 faculty were invited to complete the SETQ instruments in the duration of one month from September 2008 to September 2009. To assess reliability and validity of the instruments, we used exploratory factor analysis, inter-item correlation, reliability coefficient alpha and inter-scale correlations. We also compared composite scales from factor analysis to global ratings. Finally, the number of residents' evaluations needed per faculty for reliable assessments was calculated. A total of 613 evaluations were completed by 66 residents (85.7% response rate). 99 faculty (86.8% response rate) participated in self-evaluation. Factor analysis yielded five scales with high reliability (Cronbach's alpha for residents' and faculty): learning climate (0.86 and 0.75), professional attitude (0.89 and 0.81), communication of learning goals (0.89 and 0.82), evaluation of residents (0.87 and 0.79) and feedback (0.87 and 0.86). Item-total, inter-scale and scale-global rating correlation coefficients were significant (Pteaching qualities of obstetrics and gynecology faculty. Future research should examine improvement of teaching qualities when using SETQ.

  18. The consultation and relational empathy (CARE) measure: development and preliminary validation and reliability of an empathy-based consultation process measure.

    Science.gov (United States)

    Mercer, Stewart W; Maxwell, Margaret; Heaney, David; Watt, Graham Cm

    2004-12-01

    Empathy is a key aspect of the clinical encounter but there is a lack of patient-assessed measures suitable for general clinical settings. Our aim was to develop a consultation process measure based on a broad definition of empathy, which is meaningful to patients irrespective of their socio-economic background. Qualitative and quantitative approaches were used to develop and validate the new measure, which we have called the consultation and relational empathy (CARE) measure. Concurrent validity was assessed by correlational analysis against other validated measures in a series of three pilot studies in general practice (in areas of high or low socio-economic deprivation). Face and content validity was investigated by 43 interviews with patients from both types of areas, and by feedback from GPs and expert researchers in the field. The initial version of the new measure (pilot 1; high deprivation practice) correlated strongly (r = 0.85) with the Reynolds empathy measure (RES) and the Barrett-Lennard empathy subscale (BLESS) (r = 0.63), but had a highly skewed distribution (skew -1.879, kurtosis 3.563). Statistical analysis, and feedback from the 20 patients interviewed, the GPs and the expert researchers, led to a number of modifications. The revised, second version of the CARE measure, tested in an area of low deprivation (pilot 2) also correlated strongly with the established empathy measures (r = 0.84 versus RES and r = 0.77 versus BLESS) but had a less skewed distribution (skew -0.634, kurtosis -0.067). Internal reliability of the revised version was high (Cronbach's alpha 0.92). Patient feedback at interview (n = 13) led to only minor modification. The final version of the CARE measure, tested in pilot 3 (high deprivation practice) confirmed the validation with the other empathy measures (r = 0.85 versus RES and r = 0.84 versus BLESS) and the face validity (feedback from 10 patients). These preliminary results support the validity and reliability of the CARE

  19. Tactile acuity charts: a reliable measure of spatial acuity.

    Science.gov (United States)

    Bruns, Patrick; Camargo, Carlos J; Campanella, Humberto; Esteve, Jaume; Dinse, Hubert R; Röder, Brigitte

    2014-01-01

    For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds.

  20. Reliability and concurrent validity of postural asymmetry measurement in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Prowse, Ashleigh; Aslaksen, Berit; Kierkegaard, Marie; Furness, James; Gerdhem, Paul; Abbott, Allan

    2017-01-18

    To investigate the reliability and concurrent validity of the Baseline ® Body Level/Scoliosis meter for adolescent idiopathic scoliosis postural assessment in three anatomical planes. This is an observational reliability and concurrent validity study of adolescent referrals to the Orthopaedic department for scoliosis screening at Karolinska University Hospital, Stockholm, Sweden between March-May 2012. A total of 31 adolescents with idiopathic scoliosis (13.6 ± 0.6 years old) of mild-moderate curvatures (25° ± 12°) were consecutively recruited. Measurement of cervical, thoracic and lumbar curvatures, pelvic and shoulder tilt, and axial thoracic rotation (ATR) were performed by two trained physiotherapists in one day. The intraclass correlation coefficient (ICC) was used to determine the inter-examiner reliability (ICC2,1) and the intra-rater reliability (ICC3,3) of the Baseline ® Body Level/Scoliosis meter. Spearman's correlation analyses were used to estimate concurrent validity between the Baseline ® Body Level/Scoliosis meter and Gold Standard Cobb angles from radiographs and the Orthopaedic Systems Inc. Scoliometer. There was excellent reliability between examiners for thoracic kyphosis (ICC2,1 = 0.94), ATR (ICC2,1 = 0.92) and lumbar lordosis (ICC2,1 = 0.79). There was adequate reliability between examiners for cervical lordosis (ICC2,1 = 0.51), however poor reliability for pelvic and shoulder tilt. Both devices were reproducible in the measurement of ATR when repeated by one examiner (ICC3,3 0.98-1.00). The device had a good correlation with the Scoliometer (rho = 0.78). When compared with Cobb angle from radiographs, there was a moderate correlation for ATR (rho = 0.627). The Baseline ® Body Level/Scoliosis meter provides reliable transverse and sagittal cervical, thoracic and lumbar measurements and valid transverse plan measurements of mild-moderate scoliosis deformity.

  1. Self-report measures of prospective memory are reliable but not valid.

    Science.gov (United States)

    Uttl, Bob; Kibreab, Mekale

    2011-03-01

    Are self-report measures of prospective memory (ProM) reliable and valid? To examine this question, 240 undergraduate student volunteers completed several widely used self-report measures of ProM including the Prospective Memory Questionnaire (PMQ), the Prospective and Retrospective Memory Questionnaire (PRMQ), the Comprehensive Assessment of Prospective Memory (CAPM) questionnaire, self-reports of retrospective memory (RetM), objective measures of ProM and RetM, and measures of involvement in activities and events, memory strategies and aids use, personality and verbal intelligence. The results showed that both convergent and divergent validity of ProM self-reports are poor, even though we assessed ProM using a newly developed, reliable continuous measure. Further analyses showed that a substantial proportion of variability in ProM self-report scores was due to verbal intelligence, personality (conscientiousness, neuroticism), activities and event involvement (busyness), and use of memory strategies and aids. ProM self-reports have adequate reliability, but poor validity and should not be interpreted as reflecting ProM ability. (PsycINFO Database Record (c) 2011 APA, all rights reserved).

  2. Improved structural integrity through advances in reliable residual stress measurement: the impact of ENGIN-X

    Science.gov (United States)

    Edwards, L.; Santisteban, J. R.

    The determination of accurate reliable residual stresses is critical to many fields of structural integrity. Neutron stress measurement is a non-destructive technique that uniquely provides insights into stress fields deep within engineering components and structures. As such, it has become an increasingly important tool within engineering, leading to improved manufacturing processes to reduce stress and distortion as well as to the definition of more precise lifing procedures. This paper describes the likely impact of the next generation of dedicated engineering stress diffractometers currently being constructed and the utility of the technique using examples of residual stresses both beneficial and detrimental to structural integrity.

  3. Effect of standardized training on the reliability of the Cochrane risk of bias assessment tool: a study protocol.

    Science.gov (United States)

    da Costa, Bruno R; Resta, Nina M; Beckett, Brooke; Israel-Stahre, Nicholas; Diaz, Alison; Johnston, Bradley C; Egger, Matthias; Jüni, Peter; Armijo-Olivo, Susan

    2014-12-13

    The Cochrane risk of bias (RoB) tool has been widely embraced by the systematic review community, but several studies have reported that its reliability is low. We aim to investigate whether training of raters, including objective and standardized instructions on how to assess risk of bias, can improve the reliability of this tool. We describe the methods that will be used in this investigation and present an intensive standardized training package for risk of bias assessment that could be used by contributors to the Cochrane Collaboration and other reviewers. This is a pilot study. We will first perform a systematic literature review to identify randomized clinical trials (RCTs) that will be used for risk of bias assessment. Using the identified RCTs, we will then do a randomized experiment, where raters will be allocated to two different training schemes: minimal training and intensive standardized training. We will calculate the chance-corrected weighted Kappa with 95% confidence intervals to quantify within- and between-group Kappa agreement for each of the domains of the risk of bias tool. To calculate between-group Kappa agreement, we will use risk of bias assessments from pairs of raters after resolution of disagreements. Between-group Kappa agreement will quantify the agreement between the risk of bias assessment of raters in the training groups and the risk of bias assessment of experienced raters. To compare agreement of raters under different training conditions, we will calculate differences between Kappa values with 95% confidence intervals. This study will investigate whether the reliability of the risk of bias tool can be improved by training raters using standardized instructions for risk of bias assessment. One group of inexperienced raters will receive intensive training on risk of bias assessment and the other will receive minimal training. By including a control group with minimal training, we will attempt to mimic what many review authors

  4. The reliability of language performance measurement in language sample analysis of children aged 5-6 years

    Directory of Open Access Journals (Sweden)

    Zahra Soleymani

    2014-04-01

    Full Text Available Background and Aim: The language sample analysis (LSA is more common in other languages than Persian to study language development and assess language pathology. We studied some psychometric properties of language sample analysis in this research such as content validity of written story and its pictures, test-retest reliability, and inter-rater reliability.Methods: We wrote a story based on Persian culture from Schneider’s study. The validity of written story and drawn pictures was approved by experts. To study test-retest reliability, 30 children looked at the pictures and told their own story twice with 7-10 days interval. Children generated the story themselves and tester did not give any cue about the story. Their audio-taped story was transcribed and analyzed. Sentence and word structures were detected in the analysis.Results: Mean of experts' agreement with the validity of written story was 92.28 percent. Experts scored the quality of pictures high and excellent. There was correlation between variables in sentence and word structure (p<0.05 in test-retest, except complex sentences (p=0.137. The agreement rate was 97.1 percent in inter-rater reliability assessment of transcription. The results of inter-rater reliability of language analysis showed that correlation coefficients were significant.Conclusion: The results confirmed that the tool was valid for eliciting language sample. The consistency of language performance in repeated measurement varied from mild to high in language sample analysis approach.

  5. THE RELIABILITY AND ACCURACY OF THE TRIPLE MEASUREMENTS OF ANALOG PROCESS VARIABLES

    Directory of Open Access Journals (Sweden)

    V. A. Anishchenko

    2017-01-01

    Full Text Available The increase in unit capacity of electric equipment as well as complication of technological processes, devices control and management of the latter in power plants and substations demonstrate the need to improve the reliability and accuracy of measurement information characterizing the state of the objects being managed. The mentioned objective is particularly important for nuclear power plants, where the price of inaccuracy of measurement responsible process variables is particularly high and the error might lead to irreparable consequences. Improving the reliability and accuracy of measurements along with the improvement of the element base is provided by methods of operational validation. These methods are based on the use of information redundancy (structural, topological, temporal. In particular, information redundancy can be achieved by the simultaneous measurement of one analog variable by two (duplication or three devices (triplication i.e., triple redundancy. The problem of operational control of the triple redundant system of measurement of electrical analog variables (currents, voltages, active and reactive power and energy is considered as a special case of signal processing by an orderly sampling on the basis of majority transformation and transformation being close to majority one. Difficulties in monitoring the reliability of measurements are associated with the two tasks. First, one needs to justify the degree of truncation of the distributions of random errors of measurements and allowable residuals of the pairwise differences of the measurement results. The second task consists in formation of the algorithm of joint processing of a set of separate measurements determined as valid. The quality of control is characterized by the reliability, which adopted the synonym of validity, and accuracy of the measuring system. Taken separately, these indicators might lead to opposite results. A compromise solution is therefore proposed

  6. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease.

    Science.gov (United States)

    Strouwen, Carolien; Molenaar, Esther A L M; Keus, Samyra H J; Münks, Liesbeth; Bloem, Bastiaan R; Nieuwboer, Alice

    2016-08-01

    Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains largely unknown. The purpose of this study was to assess the reliability of DT outcome measures in patients with PD. A repeated-measures design was used. Patients with PD ("on" medication, Mini-Mental State Examination score ≥24) performed 2 cognitive tasks (ie, backward digit span task and auditory Stroop task) and 1 functional task (ie, mobile phone task) in combination with walking. Tasks were assessed at 2 time points (same hour) with an interval of 6 weeks. Test-retest reliability was assessed for gait while performing each secondary task (DT gait) for both cognitive tasks while walking (DT cognitive) and for the functional task while walking (DT functional). Sixty-two patients with PD (age=39-89 years, Hoehn and Yahr stages II-III) were included in the study. Intraclass correlation coefficients (ICCs) showed excellent reliability for DT gait measures, ranging between .86 and .95 when combined with the digit span task, between .86 and .95 when combined with the auditory Stroop task, and between .72 and .90 when combined with the mobile phone task. The standard error of measurements for DT gait speed varied between 0.06 and 0.08 m/s, leading to minimal detectable changes between 0.16 and 0.22 m/s. With regard to DT cognitive measures, reaction times showed good-to-excellent reliability (digit span task: ICC=.75; auditory Stroop task: ICC=.82). The results cannot be generalized to patients with advanced disease or to other DT measures. In people with PD, DT measures proved to be reliable for use in clinical studies and look promising for use in clinical practice to assess improvements after DT training. Large effects, however, are needed to obtain meaningful effect sizes.

  8. The Reliability of Lumbar Lordosis Measurements Using a Flexible-Rule.

    Science.gov (United States)

    The purpose of this study was to examine the intra-rater and intra-rater reliability of lumbar lordosis measurements taken with a flexible-rule. Two...coefficients (ICC) were used to determine the degree of agreement between measurements. The results suggest that measurements of lumbar lordosis with a

  9. Reliability and validity of the AutoCAD software method in lumbar lordosis measurement.

    Science.gov (United States)

    Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe

    2011-12-01

    The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis.

  10. Reliability of a Simple Physical Therapist Screening Tool to Assess Errors during Resistance Exercises for Musculoskeletal Pain

    DEFF Research Database (Denmark)

    Andersen, Kenneth Jay; Sundstrup, E.; Andersen, L. L.

    2014-01-01

    The main objective was to investigate the intra- and intertester reliability of a simple screening tool assessing errors in exercise execution by visual observation. 38 participants with no previous resistance exercise experience practiced for two weeks four typical upper limb exercises using ela...

  11. A test chip for automatic reliability measurements of interconnect vias

    NARCIS (Netherlands)

    Lippe, K.; Hasper, A.; Elfrink, G.W.; Niehof, J.; Kerkhoff, Hans G.

    1992-01-01

    A test circuit for electromigration reliability measurements was designed and tested. The device under test (DUT) is a via-hole chain. The test circuit permits simultaneous measurements of a number of DUTs, and a fatal error of one DUT does not influence the measurement results of the other DUTs.

  12. Using LISREL to Evaluate Measurement Models and Scale Reliability.

    Science.gov (United States)

    Fleishman, John; Benson, Jeri

    1987-01-01

    LISREL program was used to examine measurement model assumptions and to assess reliability of Coopersmith Self-Esteem Inventory for Children, Form B. Data on 722 third-sixth graders from over 70 schools in large urban school district were used. LISREL program assessed (1) nature of basic measurement model for scale, (2) scale invariance across…

  13. Tactile acuity charts: a reliable measure of spatial acuity.

    Directory of Open Access Journals (Sweden)

    Patrick Bruns

    Full Text Available For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds.

  14. Reliability of surface EMG measurements from the suprahyoid muscle complex

    DEFF Research Database (Denmark)

    Kothari, Mohit; Stubbs, Peter William; Pedersen, Asger Roer

    2017-01-01

    of using the suprahyoid muscle complex (SMC) using surface electromyography (sEMG) to assess changes to neural pathways by determining the reliability of measurements in healthy participants over days. Methods: Seventeen healthy participants were recruited. Measurements were performed twice with one week...... on stimulus type/intensity) had significantly different MEP values between day 1 and day 2 for single pulse and paired pulse TMS. A large stimulus artefact resulted in MEP responses that could not be assessed in four participants. Conclusions: The assessment of the SMC using sEMG following TMS was poorly...... reliable for ≈50% of participants. Although using sEMG to assess swallowing musculature function is easier to perform clinically and more comfortable to patients than invasive measures, as the measurement of muscle activity using TMS is unreliable, the use of sEMG for this muscle group is not recommended...

  15. Recommendations for certification or measurement of reliability for reliable digital archival repositories with emphasis on access

    Directory of Open Access Journals (Sweden)

    Paula Regina Ventura Amorim Gonçalez

    2017-04-01

    Full Text Available Introduction: Considering the guidelines of ISO 16363: 2012 (Space data and information transfer systems -- Audit and certification of trustworthy digital repositories and the text of CONARQ Resolution 39 for certification of Reliable Digital Archival Repository (RDC-Arq, verify the technical recommendations should be used as the basis for a digital archival repository to be considered reliable. Objective: Identify requirements for the creation of Reliable Digital Archival Repositories with emphasis on access to information from the ISO 16363: 2012 and CONARQ Resolution 39. Methodology: For the development of the study, the methodology consisted of an exploratory, descriptive and documentary theoretical investigation, since it is based on ISO 16363: 2012 and CONARQ Resolution 39. From the perspective of the problem approach, the study is qualitative and quantitative, since the data were collected, tabulated, and analyzed from the interpretation of their contents. Results: We presented a set of Checklist Recommendations for reliability measurement and/or certification for RDC-Arq with a clipping focused on the identification of requirements with emphasis on access to information is presented. Conclusions: The right to information as well as access to reliable information is a premise for Digital Archival Repositories, so the set of recommendations is directed to archivists who work in Digital Repositories and wish to verify the requirements necessary to evaluate the reliability of the Digital Repository or still guide the information professional in collecting requirements for repository reliability certification.

  16. BEAM EMITTANCE MEASUREMENT TOOL FOR CEBAF OPERATIONS

    International Nuclear Information System (INIS)

    Chevtsov, Pavel; Tiefenback, Michael

    2008-01-01

    A new software tool was created at Jefferson Lab to measure the emittance of the CEBAF electron beams. The tool consists of device control and data analysis applications. The device control application handles the work of wire scanners and writes their measurement results as well as the information about accelerator settings during these measurements into wire scanner data files. The data analysis application reads these files and calculates the beam emittance on the basis of a wire scanner data processing model. Both applications are computer platform independent but are mostly used on LINUX PCs recently installed in the accelerator control room. The new tool significantly simplifies beam emittance measurement procedures for accelerator operations and contributes to a very high availability of the CEBAF machine for the nuclear physics program at Jefferson Lab.

  17. Semiconductor measurement technology: reliability technology for cardiac pacemakers 2: a workshop report, 1976

    International Nuclear Information System (INIS)

    Schafft, H.A.

    1977-01-01

    Summaries are presented of 12 invited talks on the following topics: the procurement and assurance of high reliability electronic parts, leak rate and moisture measurements, pacemaker batteries, and pacemaker leads. The workshop, second in a series, was held in response to strong interest expressed by the pacemaker community to address technical questions relevant to the enhancement and assurance of cardiac pacemaker reliability. Discussed at the workshop were a process validation wafer concept for assuring process uniformity in device chips; screen tests for assuring reliable electronic parts; reliability prediction; reliability comparison of semiconductor technologies; mechanisms of short-circuiting dendritic growths; details of helium and radioisotope leak test methods; a study to correlate package leak rates, as measured with test gasses, and actual moisture infusion; battery life prediction; microcalorimetric measurements to nondestructively evaluate batteries for pacemakers; and an engineer's and a physician's view of the present status of pacemaker leads. References are included with most of the reports

  18. A method of bias correction for maximal reliability with dichotomous measures.

    Science.gov (United States)

    Penev, Spiridon; Raykov, Tenko

    2010-02-01

    This paper is concerned with the reliability of weighted combinations of a given set of dichotomous measures. Maximal reliability for such measures has been discussed in the past, but the pertinent estimator exhibits a considerable bias and mean squared error for moderate sample sizes. We examine this bias, propose a procedure for bias correction, and develop a more accurate asymptotic confidence interval for the resulting estimator. In most empirically relevant cases, the bias correction and mean squared error correction can be performed simultaneously. We propose an approximate (asymptotic) confidence interval for the maximal reliability coefficient, discuss the implementation of this estimator, and investigate the mean squared error of the associated asymptotic approximation. We illustrate the proposed methods using a numerical example.

  19. Measuring older adults' sedentary time: reliability, validity, and responsiveness.

    Science.gov (United States)

    Gardiner, Paul A; Clark, Bronwyn K; Healy, Genevieve N; Eakin, Elizabeth G; Winkler, Elisabeth A H; Owen, Neville

    2011-11-01

    With evidence that prolonged sitting has deleterious health consequences, decreasing sedentary time is a potentially important preventive health target. High-quality measures, particularly for use with older adults, who are the most sedentary population group, are needed to evaluate the effect of sedentary behavior interventions. We examined the reliability, validity, and responsiveness to change of a self-report sedentary behavior questionnaire that assessed time spent in behaviors common among older adults: watching television, computer use, reading, socializing, transport and hobbies, and a summary measure (total sedentary time). In the context of a sedentary behavior intervention, nonworking older adults (n = 48, age = 73 ± 8 yr (mean ± SD)) completed the questionnaire on three occasions during a 2-wk period (7 d between administrations) and wore an accelerometer (ActiGraph model GT1M) for two periods of 6 d. Test-retest reliability (for the individual items and the summary measure) and validity (self-reported total sedentary time compared with accelerometer-derived sedentary time) were assessed during the 1-wk preintervention period, using Spearman (ρ) correlations and 95% confidence intervals (CI). Responsiveness to change after the intervention was assessed using the responsiveness statistic (RS). Test-retest reliability was excellent for television viewing time (ρ (95% CI) = 0.78 (0.63-0.89)), computer use (ρ (95% CI) = 0.90 (0.83-0.94)), and reading (ρ (95% CI) = 0.77 (0.62-0.86)); acceptable for hobbies (ρ (95% CI) = 0.61 (0.39-0.76)); and poor for socializing and transport (ρ < 0.45). Total sedentary time had acceptable test-retest reliability (ρ (95% CI) = 0.52 (0.27-0.70)) and validity (ρ (95% CI) = 0.30 (0.02-0.54)). Self-report total sedentary time was similarly responsive to change (RS = 0.47) as accelerometer-derived sedentary time (RS = 0.39). The summary measure of total sedentary time has good repeatability and modest validity and is

  20. Content Validity of a Tool Measuring Medication Errors.

    Science.gov (United States)

    Tabassum, Nishat; Allana, Saleema; Saeed, Tanveer; Dias, Jacqueline Maria

    2015-08-01

    The objective of this study was to determine content and face validity of a tool measuring medication errors among nursing students in baccalaureate nursing education. Data was collected from the Aga Khan University School of Nursing and Midwifery (AKUSoNaM), Karachi, from March to August 2014. The tool was developed utilizing literature and the expertise of the team members, expert in different areas. The developed tool was then sent to five experts from all over Karachi for ensuring the content validity of the tool, which was measured on relevance and clarity of the questions. The Scale Content Validity Index (S-CVI) for clarity and relevance of the questions was found to be 0.94 and 0.98, respectively. The tool measuring medication errors has an excellent content validity. This tool should be used for future studies on medication errors, with different study populations such as medical students, doctors, and nurses.

  1. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease

    NARCIS (Netherlands)

    Strouwen, C.; Molenaar, E.A.; Keus, S.H.; Munks, L.; Bloem, B.R.; Nieuwboer, A.

    2016-01-01

    BACKGROUND: Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains

  2. Reliability analysis for manual radiographic measures of rotatory subluxation or lateral listhesis in adult scoliosis.

    Science.gov (United States)

    Freedman, Brett A; Horton, William C; Rhee, John M; Edwards, Charles C; Kuklo, Timothy R

    2009-03-15

    Retrospective observational study. To define the inter- and intraobserver reliability of 3 measures of rotatory subluxation (RS) in adult scoliosis (AS). RS is a hallmark of AS. To accurately track this measure, one must know its reliability. Reliability testing has not been performed. PA 36" films of 29 AS patients were collected from one surgeon's practice. Three observers on 2 separate occasions measured all levels with >or=3-mm RS (60 levels, 360 measurements) on the convexity of the involved segment using 3 different techniques-midbody (MB), endplate (EP), and centroid (C). These data were then analyzed to determine the intraclass correlation coefficient (ICC) for inter- and intraobserver reliability. The thoracolumbar/lumbar curve (average 58 degrees ) was the major curve for the majority (62%) of patients. RS at L3/4 was most common (35%). The overall inter- and intraobserver reliability was good-excellent for all methods, but the centroid method consistently had the highest ICC. ICC correlated with observer experience. Moderate-severe arthritic change (present in 55%) and poor image quality (52%) decreased ICC, but it still remained good-excellent for each measure. The reproducibility coefficient for each measure was 4 mm for MB and 2.8 mm for C and EP. MB, EP, and C are reliable techniques to measure RS even in elderly arthritic spines, but the methods inherently produce different values for a given level. The centroid method is most reliable and least influenced by experience. The EP method is easy to perform and very reliable. Spine surgeons should pick their preferred method and apply it consistently. Changes >3 mm suggest RS progression. RS may be a useful measure in addition to Cobb angle in AS. Having defined measurement reliability, the role of RS progression in surgical indications and patient outcomes can be evaluated.

  3. Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines

    Directory of Open Access Journals (Sweden)

    Cameron Alyse FM

    2009-11-01

    Full Text Available Abstract Background Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end Philips HD11 Ultrasound machine and clinically orientated Chison 8300 Deluxe Digital Portable Ultrasound System. Methods The abductor hallucis muscle of both the left and right feet of thirty asymptomatic participants was imaged and then measured using both ultrasound machines. Interclass correlation coefficients (ICC with 95% confidence intervals (CI were used to calculate both within and between session intra-tester reliability. Standard error of the measurement (SEM calculations were undertaken to assess difference between the actual measured score across trials and the smallest real difference (SRD was calculated from the SEM to indicate the degree of change that would exceed the expected trial to trial variability. Results The ICCs, SEM and SRD for dorso-plantar thickness and medial-lateral length were shown to have excellent to high within and between-session reliability for both ultrasound machines. The between-session reliability indices for cross-sectional area were acceptable for both ultrasound machines. Conclusion The results of the current study suggest that regardless of the type ultrasound machine, intra-tester reliability for the measurement the abductor hallucis muscle parameters is very high.

  4. Elaboration of reduced versions of Measurement tools: A practical Perspective

    Directory of Open Access Journals (Sweden)

    Nekane Balluerka

    2012-01-01

    Full Text Available The aim of the present study is to show, from a practical perspective, the guidelines that may be followed to create a reduced version of a measurement tool. Therefore, it describes in detail the process of creating the reduced Basque version of the CDS scale (Children's Depression Scale; Lang and Tisher, 1978, which measures depression in children and adolescents. In a first study, the items that make up the reduced version of the CDS (CDS-R are selected from a set of analysis conducted on a sample of 886 children and adolescents who were administered the extensive version of the CDS adapted to the Basque language (Balluerka, Gorostiaga, and Haranburu, 2012. Subsequently, the CDS-R is validated on a sample of 2,165 participants. This second study examines the factorial structure, the internal consistency and the temporal stability of the instrument, as well as the relationship between its dimensions and gender, academic performance, emotional intelligence and attachment. Thus, evidence is obtained on the reliability and validity of the reduced version of the instrument, which guarantees suitable evaluation of the construct the instrument is intended to measure.

  5. Development, initial reliability and validity testing of an observational tool for assessing technical skills of operating room nurses.

    Science.gov (United States)

    Sevdalis, Nick; Undre, Shabnam; Henry, Janet; Sydney, Elaine; Koutantji, Mary; Darzi, Ara; Vincent, Charles A

    2009-09-01

    The recent emergence of the Systems Approach to the safety and quality of surgical care has triggered individual and team skills training modules for surgeons and anaesthetists and relevant observational assessment tools have been developed. To develop an observational tool that captures operating room (OR) nurses' technical skill and can be used for assessment and training. The Imperial College Assessment of Technical Skills for Nurses (ICATS-N) assesses (i) gowning and gloving, (ii) setting up instrumentation, (iii) draping, and (iv) maintaining sterility. Three to five observable behaviours have been identified for each skill and are rated on 1-6 scales. Feasibility and aspects of reliability and validity were assessed in 20 simulation-based crisis management training modules for trainee nurses and doctors, carried out in a Simulated Operating Room. The tool was feasible to use in the context of simulation-based training. Satisfactory reliability (Cronbach alpha) was obtained across trainers' and trainees' scores (analysed jointly and separately). Moreover, trainer nurse's ratings of the four skills correlated positively, thus indicating adequate content validity. Trainer's and trainees' ratings did not correlate. Assessment of OR nurses' technical skill is becoming a training priority. The present evidence suggests that the ICATS-N could be considered for use as an assessment/training tool for junior OR nurses.

  6. Test-Retest Reliability of an Experienced Global Trigger Tool Review Team

    DEFF Research Database (Denmark)

    Bjørn, Brian; Anhøj, Jacob; Østergaard, Mette

    2018-01-01

    and review 2 and between period 1 and period 2. The increase was solely in category E, minor temporary harm. CONCLUSIONS: The very experienced GTT team could not reproduce harm rates found in earlier reviews. We conclude that GTT in its present form is not a reliable measure of harm rate over time....

  7. A new measurement of workload in Web application reliability assessment

    Directory of Open Access Journals (Sweden)

    CUI Xia

    2015-02-01

    Full Text Available Web application has been popular in various fields of social life.It becomes more and more important to study the reliability of Web application.In this paper the definition of Web application failure is firstly brought out,and then the definition of Web application reliability.By analyzing data in the IIS server logs and selecting corresponding usage and information delivery failure data,the paper study the feasibility of Web application reliability assessment from the perspective of Web software system based on IIS server logs.Because the usage for a Web site often has certain regularity,a new measurement of workload in Web application reliability assessment is raised.In this method,the unit is removed by weighted average technique;and the weights are assessed by setting objective function and optimization.Finally an experiment was raised for validation.The experiment result shows the assessment of Web application reliability base on the new workload is better.

  8. Reliability of the Bulb Dynamometer for Assessing Grip Strength

    Directory of Open Access Journals (Sweden)

    Colleen Maher

    2018-04-01

    Full Text Available Background: Hand function is an overall indicator of health and is often measured using grip strength. Handheld dynamometry is the most common method of measuring grip strength. The purpose of this study was to determine the inter-rater and test-retest reliability, the reliability of one trial versus three trials, and the preliminary norms for a young adult population using the Baseline® Pneumatic Squeeze Bulb Dynamometer (30 psi. Methods: This study used a one-group methodological design. One hundred and three healthy adults (30 males and 73 females were recruited. Six measurements were collected for each hand per participant. The data was analyzed using Intraclass Correlation Coefficients (ICC two-way effects model (2,2 and paired-samples t-tests. Results: The ICC for inter-rater reliability ranged from 0.955 to 0.977. Conclusion: The results of this study suggest that the bulb dynamometer is a reliable tool to measure grip strength and should be further explored for reliable and valid use in diverse populations and as an alternative to the Jamar dynamometer.

  9. Development of Reliable and Validated Tools to Evaluate Technical Resuscitation Skills in a Pediatric Simulation Setting: Resuscitation and Emergency Simulation Checklist for Assessment in Pediatrics.

    Science.gov (United States)

    Faudeux, Camille; Tran, Antoine; Dupont, Audrey; Desmontils, Jonathan; Montaudié, Isabelle; Bréaud, Jean; Braun, Marc; Fournier, Jean-Paul; Bérard, Etienne; Berlengi, Noémie; Schweitzer, Cyril; Haas, Hervé; Caci, Hervé; Gatin, Amélie; Giovannini-Chami, Lisa

    2017-09-01

    To develop a reliable and validated tool to evaluate technical resuscitation skills in a pediatric simulation setting. Four Resuscitation and Emergency Simulation Checklist for Assessment in Pediatrics (RESCAPE) evaluation tools were created, following international guidelines: intraosseous needle insertion, bag mask ventilation, endotracheal intubation, and cardiac massage. We applied a modified Delphi methodology evaluation to binary rating items. Reliability was assessed comparing the ratings of 2 observers (1 in real time and 1 after a video-recorded review). The tools were assessed for content, construct, and criterion validity, and for sensitivity to change. Inter-rater reliability, evaluated with Cohen kappa coefficients, was perfect or near-perfect (>0.8) for 92.5% of items and each Cronbach alpha coefficient was ≥0.91. Principal component analyses showed that all 4 tools were unidimensional. Significant increases in median scores with increasing levels of medical expertise were demonstrated for RESCAPE-intraosseous needle insertion (P = .0002), RESCAPE-bag mask ventilation (P = .0002), RESCAPE-endotracheal intubation (P = .0001), and RESCAPE-cardiac massage (P = .0037). Significantly increased median scores over time were also demonstrated during a simulation-based educational program. RESCAPE tools are reliable and validated tools for the evaluation of technical resuscitation skills in pediatric settings during simulation-based educational programs. They might also be used for medical practice performance evaluations. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. A New Tool for Nutrition App Quality Evaluation (AQEL): Development, Validation, and Reliability Testing.

    Science.gov (United States)

    DiFilippo, Kristen Nicole; Huang, Wenhao; Chapman-Novakofski, Karen M

    2017-10-27

    The extensive availability and increasing use of mobile apps for nutrition-based health interventions makes evaluation of the quality of these apps crucial for integration of apps into nutritional counseling. The goal of this research was the development, validation, and reliability testing of the app quality evaluation (AQEL) tool, an instrument for evaluating apps' educational quality and technical functionality. Items for evaluating app quality were adapted from website evaluations, with additional items added to evaluate the specific characteristics of apps, resulting in 79 initial items. Expert panels of nutrition and technology professionals and app users reviewed items for face and content validation. After recommended revisions, nutrition experts completed a second AQEL review to ensure clarity. On the basis of 150 sets of responses using the revised AQEL, principal component analysis was completed, reducing AQEL into 5 factors that underwent reliability testing, including internal consistency, split-half reliability, test-retest reliability, and interrater reliability (IRR). Two additional modifiable constructs for evaluating apps based on the age and needs of the target audience as selected by the evaluator were also tested for construct reliability. IRR testing using intraclass correlations (ICC) with all 7 constructs was conducted, with 15 dietitians evaluating one app. Development and validation resulted in the 51-item AQEL. These were reduced to 25 items in 5 factors after principal component analysis, plus 9 modifiable items in two constructs that were not included in principal component analysis. Internal consistency and split-half reliability of the following constructs derived from principal components analysis was good (Cronbach alpha >.80, Spearman-Brown coefficient >.80): behavior change potential, support of knowledge acquisition, app function, and skill development. App purpose split half-reliability was .65. Test-retest reliability showed no

  11. Reliability of in-Shoe Plantar Pressure Measurements in Rheumatoid Arthritis Patients

    Science.gov (United States)

    Vidmar, Gaj; Novak, Primoz

    2009-01-01

    Plantar pressures measurement is a frequently used method in rehabilitation and related research. Metric characteristics of the F-Scan system have been assessed from different standpoints and in different patients, but not its reliability in rheumatoid arthritis patients. Therefore, our objective was to assess reliability of the F-Scan plantar…

  12. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study

    Science.gov (United States)

    West, Jane; Manchester, Ben; Wright, John; Lawlor, Debbie A; Waiblinger, Dagmar

    2011-01-01

    Summary West J, Manchester B, Wright J, Lawlor DA, Waiblinger D. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study. Paediatric and Perinatal Epidemiology 2011. Assessing neonatal size reliably is important for research and clinical practice. The aim of this study was to examine the reliability of routine clinical measurements of neonatal circumferences and of skinfold thicknesses assessed for research purposes. All measurements were undertaken on the same population of neonates born in a large maternity unit in Bradford, UK. Technical error of measurement (TEM), relative TEM and the coefficient of reliability are reported. Intra-observer TEMs for routine circumference measurements were all below 0.4 cm and were generally within ±2-times the mean. Inter-observer TEM ranged from 0.20 to 0.36 cm for head circumference, 0.19 to 0.39 cm for mid upper arm circumference and from 0.39 to 0.77 cm for abdominal circumference. Intra and inter-observer TEM for triceps skinfold thickness ranged from 0.22 to 0.35 mm and 0.15 to 0.54 mm, respectively. Subscapular skinfold thickness TEM values were 0.14 to 0.25 mm for intra-observer measurements and 0.17 to 0.63 mm for inter-observer measurements. Relative TEM values for routine circumferences were all below 4.00% but varied between 2.88% and 14.23% for research skinfold measurements. Reliability was mostly between 80% and 99% for routine circumference measurements and ≥70% for most research skinfold measurements. Routine clinical measurements of neonatal circumferences are reliably assessed in Bradford. Assessing skinfolds in neonates has variable reliability, but on the whole is good. The greater intra-observer, compared with inter-observer, reliability for both sets of measurements highlights the importance of having a minimal number of assessors whenever possible. PMID:21281329

  13. Validity and Reliability of a Wearable Inertial Sensor to Measure Velocity and Power in the Back Squat and Bench Press.

    Science.gov (United States)

    Orange, Samuel T; Metcalfe, James W; Liefeith, Andreas; Marshall, Phil; Madden, Leigh A; Fewster, Connor R; Vince, Rebecca V

    2018-05-08

    Orange, ST, Metcalfe, JW, Liefeith, A, Marshall, P, Madden, LA, Fewster, CR, and Vince, RV. Validity and reliability of a wearable inertial sensor to measure velocity and power in the back squat and bench press. J Strength Cond Res XX(X): 000-000, 2018-This study examined the validity and reliability of a wearable inertial sensor to measure velocity and power in the free-weight back squat and bench press. Twenty-nine youth rugby league players (18 ± 1 years) completed 2 test-retest sessions for the back squat followed by 2 test-retest sessions for the bench press. Repetitions were performed at 20, 40, 60, 80, and 90% of 1 repetition maximum (1RM) with mean velocity, peak velocity, mean power (MP), and peak power (PP) simultaneously measured using an inertial sensor (PUSH) and a linear position transducer (GymAware PowerTool). The PUSH demonstrated good validity (Pearson's product-moment correlation coefficient [r]) and reliability (intraclass correlation coefficient [ICC]) only for measurements of MP (r = 0.91; ICC = 0.83) and PP (r = 0.90; ICC = 0.80) at 20% of 1RM in the back squat. However, it may be more appropriate for athletes to jump off the ground with this load to optimize power output. Further research should therefore evaluate the usability of inertial sensors in the jump squat exercise. In the bench press, good validity and reliability were evident only for the measurement of MP at 40% of 1RM (r = 0.89; ICC = 0.83). The PUSH was unable to provide a valid and reliable estimate of any other criterion variable in either exercise. Practitioners must be cognizant of the measurement error when using inertial sensor technology to quantify velocity and power during resistance training, particularly with loads other than 20% of 1RM in the back squat and 40% of 1RM in the bench press.

  14. Frequency Response Analysis Tool

    Energy Technology Data Exchange (ETDEWEB)

    Etingov, Pavel V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kosterev, Dmitry [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dai, T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    Frequency response has received a lot of attention in recent years at the national level, which culminated in the development and approval of North American Electricity Reliability Corporation (NERC) BAL-003-1 Frequency Response and Frequency Bias Setting Reliability Standard. This report is prepared to describe the details of the work conducted by Pacific Northwest National Laboratory (PNNL) in collaboration with the Bonneville Power Administration and Western Electricity Coordinating Council (WECC) Joint Synchronized Information Subcommittee (JSIS) to develop a frequency response analysis tool (FRAT). The document provides the details on the methodology and main features of the FRAT. The tool manages the database of under-frequency events and calculates the frequency response baseline. Frequency response calculations are consistent with frequency response measure (FRM) in NERC BAL-003-1 for an interconnection and balancing authority. The FRAT can use both phasor measurement unit (PMU) data, where available, and supervisory control and data acquisition (SCADA) data. The tool is also capable of automatically generating NERC Frequency Response Survey (FRS) forms required by BAL-003-1 Standard.

  15. Construct validity and inter-rater reliability of the Dutch activity measure for post-acute care "6-clicks" basic mobility form to assess the mobility of hospitalized patients.

    Science.gov (United States)

    Geelen, Sven Jacobus Gertruda; Valkenet, Karin; Veenhof, Cindy

    2018-05-12

    To evaluate the construct validity and the inter-rater reliability of the Dutch Activity Measure for Post-Acute Care "6-clicks" Basic Mobility short form measuring the patient's mobility in Dutch hospital care. First, the "6-clicks" was translated by using a forward-backward translation protocol. Next, 64 patients were assessed by the physiotherapist to determine the validity while being admitted to the Internal Medicine wards of a university medical center. Six hypotheses were tested regarding the construct "mobility" which showed that: Better "6-clicks" scores were related to less restrictive pre-admission living situations (p = 0.011), less restrictive discharge locations (p = 0.001), more independence in activities of daily living (p = 0.001) and less physiotherapy visits (p Dutch "6-clicks" shows a good construct validity and moderate-to-excellent inter-rater reliability when used to assess the mobility of hospitalized patients. Implications for Rehabilitation Even though various measurement tools have been developed, it appears the majority of physiotherapists working in a hospital currently do not use these tools as a standard part of their care. The Activity Measure for Post-Acute Care "6-clicks" Basic Mobility is the only tool which is designed to be short, easy to use within usual care and has been validated in the entire hospital population. This study shows that the Dutch version of the Activity Measure for Post-Acute Care "6-clicks" Basic Mobility form is a valid, easy to use, quick tool to assess the basic mobility of Dutch hospitalized patients.

  16. The gothic arch: a reliable measurement for developmental dysplasia of the hip.

    Science.gov (United States)

    Herickhoff, Paul K; O'Brien, Megan K; Dolan, Lori A; Morcuende, Jose A; Peterson, Jonathan B; Weinstein, Stuart L

    2013-01-01

    The "Gothic Arch" is a radio-graphic finding on AP pelvis x-rays postulated to be predictive of hip osteoarthritis. The purpose of this study was to determine the reliability of measurement of the Gothic Arch in patients with no known hip pathology and patients with unilateral developmental dysplasia of the hip (DDH). After obtaining IRB approval, nine skeletally mature patients (18 hips) with no known hip pathology were selected to serve as the control group. The AP pelvis x-rays at skeletal maturity of eight patients (16 hips) with unilateral DDH treated with closed reduction and casting comprised the comparison group. A digitizing program was designed to measure the Gothic Arch based on landmarks identified by the user. Two pediatric orthopaedic surgeons and two orthopaedic residents completed the program on two separate occasions. Intra-and interobserver reliability were determined using intraclass cor-relation coefficients (ICC) for continuous variables. Both the unilateral DDH group and the control group demonstrated excellent inter- and intraobserver reliability (ICC >0.70) for base, height, area, and orientation of the Gothic Arch, but poor reliability (ICC Gothic Arch can be reliably measured on AP pelvis x-rays of patients with normal and dysplastic hips. III, Diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.

  17. A design tool to study the impact of mission-profile on the reliability of SiC-based PV-inverter devices

    DEFF Research Database (Denmark)

    Sintamarean, Nicolae Cristian; Wang, Huai; Blaabjerg, Frede

    2014-01-01

    and is further used as an input to a lifetime model. The proposed reliability oriented design tool is used to study the impact of MP and device degradation (aging) in the PV-inverter lifetime. The obtained results indicate that the MP of the field where the PV-inverter is operating has an important impact......This paper introduces a reliability-oriented design tool for a new generation of grid connected PV-inverters. The proposed design tool consists of a real field mission profile model (for one year operation in USA-Arizona), a PV-panel model, a grid connected PV-inverter model, an electro......-thermal model and the lifetime model of the power semiconductor devices. A simulation model able to consider one year real field operation conditions (solar irradiance and ambient temperature) is developed. Thus, one year estimation of the converter devices thermal loading distribution is achieved...

  18. Measurements of Weight Bearing Asymmetry Using the Nintendo Wii Fit Balance Board Are Not Reliable for Older Adults and Individuals With Stroke.

    Science.gov (United States)

    Liuzzo, Derek M; Peters, Denise M; Middleton, Addie; Lanier, Wes; Chain, Rebecca; Barksdale, Brittany; Fritz, Stacy L

    Clinicians and researchers have used bathroom scales, balance performance monitors with feedback, postural scale analysis, and force platforms to evaluate weight bearing asymmetry (WBA). Now video game consoles offer a novel alternative for assessing this construct. By using specialized software, the Nintendo Wii Fit balance board can provide reliable measurements of WBA in healthy, young adults. However, reliability of measurements obtained using only the factory settings to assess WBA in older adults and individuals with stroke has not been established. To determine whether measurements of WBA obtained using the Nintendo Wii Fit balance board and default settings are reliable in older adults and individuals with stroke. Weight bearing asymmetry was assessed using the Nintendo Wii Fit balance board in 2 groups of participants-individuals older than 65 years (n = 41) and individuals with stroke (n = 41). Participants were given a standardized set of instructions and were not provided auditory or visual feedback. Two trials were performed. Intraclass correlation coefficients (ICC), standard error of measure (SEM), and minimal detectable change (MDC) scores were determined for each group. The ICC for the older adults sample was 0.59 (0.35-0.76) with SEM95 = 6.2% and MDC95 = 8.8%. The ICC for the sample including individuals with stroke was 0.60 (0.47-0.70) with SEM95 = 9.6% and MDC95 = 13.6%. Although measurements of WBA obtained using the Nintendo Wii Fit balance board, and its default factory settings, demonstrate moderate reliability in older adults and individuals with stroke, the relatively high associated SEM and MDC values substantially reduce the clinical utility of the Nintendo Wii Fit balance board as an assessment tool for WBA. Weight bearing asymmetry cannot be measured reliably in older adults and individuals with stroke using the Nintendo Wii Fit balance board without the use of specialized software.

  19. Insightful practice: a reliable measure for medical revalidation

    Science.gov (United States)

    Guthrie, Bruce; Sullivan, Frank M; Mercer, Stewart W; Russell, Andrew; Bruce, David A

    2012-01-01

    Background Medical revalidation decisions need to be reliable if they are to reassure on the quality and safety of professional practice. This study tested an innovative method in which general practitioners (GPs) were assessed on their reflection and response to a set of externally specified feedback. Setting and participants 60 GPs and 12 GP appraisers in the Tayside region of Scotland, UK. Methods A feedback dataset was specified as (1) GP-specific data collected by GPs themselves (patient and colleague opinion; open book self-evaluated knowledge test; complaints) and (2) Externally collected practice-level data provided to GPs (clinical quality and prescribing safety). GPs' perceptions of whether the feedback covered UK General Medical Council specified attributes of a ‘good doctor’ were examined using a mapping exercise. GPs' professionalism was examined in terms of appraiser assessment of GPs' level of insightful practice, defined as: engagement with, insight into and appropriate action on feedback data. The reliability of assessment of insightful practice and subsequent recommendations on GPs' revalidation by face-to-face and anonymous assessors were investigated using Generalisability G-theory. Main outcome measures Coverage of General Medical Council attributes by specified feedback and reliability of assessor recommendations on doctors' suitability for revalidation. Results Face-to-face assessment proved unreliable. Anonymous global assessment by three appraisers of insightful practice was highly reliable (G=0.85), as were revalidation decisions using four anonymous assessors (G=0.83). Conclusions Unlike face-to-face appraisal, anonymous assessment of insightful practice offers a valid and reliable method to decide GP revalidation. Further validity studies are needed. PMID:22653078

  20. Translation, reliability, and clinical utility of the Melbourne Assessment 2.

    Science.gov (United States)

    Gerber, Corinna N; Plebani, Anael; Labruyère, Rob

    2017-10-12

    The aims were to (i) provide a German translation of the Melbourne Assessment 2 (MA2), a quantitative test to measure unilateral upper limb function in children with neurological disabilities and (ii) to evaluate its reliability and aspects of clinical utility. After its translation into German and approval of the back translation by the original authors, the MA2 was performed and videotaped twice with 30 children with neuromotor disorders. For each participant, two raters scored the video of the first test for inter-rater reliability. To determine test-retest reliability, one rater additionally scored the video of the second test while the other rater repeated the scoring of the first video to evaluate intra-rater reliability. Time needed for rater training, test administration, and scoring was recorded. The four subscale scores showed excellent intra-, inter-rater, and test-retest reliability with intraclass correlation coefficients of 0.90-1.00 (95%-confidence intervals 0.78-1.00). Score items revealed substantial to almost perfect intra-rater reliability (weighted kappa k w  = 0.66-1.00) for the more affected side. Score item inter-rater and test-retest reliability of the same extremity were, with one exception, moderate to almost perfect (k w  = 0.42-0.97; k w  = 0.40-0.89). Furthermore, the MA2 was feasible and acceptable for patients and clinicians. The MA2 showed excellent subscale and moderate to almost perfect score item reliability. Implications for Rehabilitation There is a lack of high-quality studies about psychometric properties of upper limb measurement tools in the neuropediatric population. The Melbourne Assessment 2 is a promising tool for reliable measurement of unilateral upper limb movement quality in the neuropediatric population. The Melbourne Assessment 2 is acceptable and practicable to therapists and patients for routine use in clinical care.

  1. Efficiency criteria for high reliability measured system structures

    International Nuclear Information System (INIS)

    Sal'nikov, N.L.

    2012-01-01

    The procedures of structural redundancy are usually used to develop high reliability measured systems. To estimate efficiency of such structures the criteria to compare different systems has been developed. So it is possible to develop more exact system by inspection of redundant system data unit stochastic characteristics in accordance with the developed criteria [ru

  2. Reliability generalization of the Multigroup Ethnic Identity Measure-Revised (MEIM-R).

    Science.gov (United States)

    Herrington, Hayley M; Smith, Timothy B; Feinauer, Erika; Griner, Derek

    2016-10-01

    [Correction Notice: An Erratum for this article was reported in Vol 63(5) of Journal of Counseling Psychology (see record 2016-33161-001). The name of author Erika Feinauer was misspelled as Erika Feinhauer. All versions of this article have been corrected.] Individuals' strength of ethnic identity has been linked with multiple positive indicators, including academic achievement and overall psychological well-being. The measure researchers use most often to assess ethnic identity, the Multigroup Ethnic Identity Measure (MEIM), underwent substantial revision in 2007. To inform scholars investigating ethnic identity, we performed a reliability generalization analysis on data from the revised version (MEIM-R) and compared it with data from the original MEIM. Random-effects weighted models evaluated internal consistency coefficients (Cronbach's alpha). Reliability coefficients for the MEIM-R averaged α = .88 across 37 samples, a statistically significant increase over the average of α = .84 for the MEIM across 75 studies. Reliability coefficients for the MEIM-R did not differ across study and participant characteristics such as sample gender and ethnic composition. However, consistently lower reliability coefficients averaging α = .81 were found among participants with low levels of education, suggesting that greater attention to data reliability is warranted when evaluating the ethnic identity of individuals such as middle-school students. Future research will be needed to ascertain whether data with other measures of aspects of personal identity (e.g., racial identity, gender identity) also differ as a function of participant level of education and associated cognitive or maturation processes. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  3. Reliable identification of deep sulcal pits: the effects of scan session, scanner, and surface extraction tool.

    Directory of Open Access Journals (Sweden)

    Kiho Im

    Full Text Available Sulcal pit analysis has been providing novel insights into brain function and development. The purpose of this study was to evaluate the reliability of sulcal pit extraction with respect to the effects of scan session, scanner, and surface extraction tool. Five subjects were scanned 4 times at 3 MRI centers and other 5 subjects were scanned 3 times at 2 MRI centers, including 1 test-retest session. Sulcal pits were extracted on the white matter surfaces reconstructed with both Montreal Neurological Institute and Freesurfer pipelines. We estimated similarity of the presence of sulcal pits having a maximum value of 1 and their spatial difference within the same subject. The tests showed high similarity of the sulcal pit presence and low spatial difference. The similarity was more than 0.90 and the spatial difference was less than 1.7 mm in most cases according to different scan sessions or scanners, and more than 0.85 and about 2.0 mm across surface extraction tools. The reliability of sulcal pit extraction was more affected by the image processing-related factors than the scan session or scanner factors. Moreover, the similarity of sulcal pit distribution appeared to be largely influenced by the presence or absence of the sulcal pits on the shallow and small folds. We suggest that our sulcal pit extraction from MRI is highly reliable and could be useful for clinical applications as an imaging biomarker.

  4. Reliable identification of deep sulcal pits: the effects of scan session, scanner, and surface extraction tool.

    Science.gov (United States)

    Im, Kiho; Lee, Jong-Min; Jeon, Seun; Kim, Jong-Heon; Seo, Sang Won; Na, Duk L; Grant, P Ellen

    2013-01-01

    Sulcal pit analysis has been providing novel insights into brain function and development. The purpose of this study was to evaluate the reliability of sulcal pit extraction with respect to the effects of scan session, scanner, and surface extraction tool. Five subjects were scanned 4 times at 3 MRI centers and other 5 subjects were scanned 3 times at 2 MRI centers, including 1 test-retest session. Sulcal pits were extracted on the white matter surfaces reconstructed with both Montreal Neurological Institute and Freesurfer pipelines. We estimated similarity of the presence of sulcal pits having a maximum value of 1 and their spatial difference within the same subject. The tests showed high similarity of the sulcal pit presence and low spatial difference. The similarity was more than 0.90 and the spatial difference was less than 1.7 mm in most cases according to different scan sessions or scanners, and more than 0.85 and about 2.0 mm across surface extraction tools. The reliability of sulcal pit extraction was more affected by the image processing-related factors than the scan session or scanner factors. Moreover, the similarity of sulcal pit distribution appeared to be largely influenced by the presence or absence of the sulcal pits on the shallow and small folds. We suggest that our sulcal pit extraction from MRI is highly reliable and could be useful for clinical applications as an imaging biomarker.

  5. Validity and reliability of a tool for determining appropriateness of days of stay: an observational study in the orthopedic intensive rehabilitation facilities in Italy.

    Directory of Open Access Journals (Sweden)

    Aida Bianco

    Full Text Available OBJECTIVES: To test the validity and reliability of a tool specifically developed for the evaluation of appropriateness in rehabilitation facilities and to assess the prevalence of appropriateness of the days of stay. METHODS: The tool underwent a process of cross-cultural translation, content validity, and test-retest validity. Two hospital-based rehabilitation wards providing intensive rehabilitation care located in the Region of Calabria, Southern Italy, were randomly selected. A review of medical records on a random sample of patients aged 18 or more was performed. RESULTS: The process of validation resulted in modifying some of the criteria used for the evaluation of appropriateness. Test-retest reliability showed that the agreement and the k statistic for the assessment of the appropriateness of days of stay were 93.4% and 0.82, respectively. A total of 371 patient days was reviewed, and 22.9% of the days of stay in the sample were judged to be inappropriate. The most frequently selected appropriateness criterion was the evaluation of patients by rehabilitation professionals for at least 3 hours on the index day (40.8%; moreover, the most frequent primary reason accounting for the inappropriate days of stay was social and/or family environment issues (34.1%. CONCLUSIONS: The findings showed that the tool used is reliable and have adequate validity to measure the extent of appropriateness of days of stay in rehabilitation facilities and that the prevalence of inappropriateness is contained in the investigated settings. Further research is needed to expand appropriateness evaluation to other rehabilitation settings, and to investigate more thoroughly internal and external causes of inappropriate use of rehabilitation services.

  6. Characterization of perovskite solar cells: Towards a reliable measurement protocol

    Directory of Open Access Journals (Sweden)

    Eugen Zimmermann

    2016-09-01

    Full Text Available Lead halide perovskite solar cells have shown a tremendous rise in power conversion efficiency with reported record efficiencies of over 20% making this material very promising as a low cost alternative to conventional inorganic solar cells. However, due to a differently severe “hysteretic” behaviour during current density-voltage measurements, which strongly depends on scan rate, device and measurement history, preparation method, device architecture, etc., commonly used solar cell measurements do not give reliable or even reproducible results. For the aspect of commercialization and the possibility to compare results of different devices among different laboratories, it is necessary to establish a measurement protocol which gives reproducible results. Therefore, we compare device characteristics derived from standard current density-voltage measurements with stabilized values obtained from an adaptive tracking of the maximum power point and the open circuit voltage as well as characteristics extracted from time resolved current density-voltage measurements. Our results provide insight into the challenges of a correct determination of device performance and propose a measurement protocol for a reliable characterisation which is easy to implement and has been tested on varying perovskite solar cells fabricated in different laboratories.

  7. Virtual reality as a metric for the assessment of laparoscopic psychomotor skills. Learning curves and reliability measures.

    Science.gov (United States)

    Gallagher, A G; Satava, R M

    2002-12-01

    The objective assessment of the psychomotor skills of surgeons is now a priority; however, this is a difficult task because of measurement difficulties associated with the assessment of surgery in vivo. In this study, virtual reality (VR) was used to overcome these problems. Twelve experienced (>50 minimal-access procedures), 12 inexperienced laparoscopic surgeons (Virtual Reality (MIST VR). Experienced laparoscopic surgeons performed the tasks significantly (p < 0.01) faster, with less error, more economy in the movement of instruments and the use of diathermy, and with greater consistency in performance. The standardized coefficient alpha for performance measures ranged from a = 0.89 to 0.98, showing high internal measurement consistency. Test-retest reliability ranged from r = 0.96 to r = 0.5. VR is a useful tool for evaluating the psychomotor skills needed to perform laparoscopic surgery.

  8. Improving Metrological Reliability of Information-Measuring Systems Using Mathematical Modeling of Their Metrological Characteristics

    Science.gov (United States)

    Kurnosov, R. Yu; Chernyshova, T. I.; Chernyshov, V. N.

    2018-05-01

    The algorithms for improving the metrological reliability of analogue blocks of measuring channels and information-measuring systems are developed. The proposed algorithms ensure the optimum values of their metrological reliability indices for a given analogue circuit block solution.

  9. Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

    Energy Technology Data Exchange (ETDEWEB)

    You, Sung Hye; Son, Gyu Ri; Lee, Nam Joon [Dept. of Radiology, Korea University Anam Hospital, Seoul (Korea, Republic of); Suh, Sangil; Ryoo, In Seon; Seol, Hae Young [Dept. of Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, Young Hen; Seo, Hyung Suk [Dept. of Radiology, Korea University Ansan Hospital, Ansan (Korea, Republic of)

    2017-01-15

    The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL), for measuring the volume of parathyroid glands. Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D) and three-dimensional (3D) methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs) and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism.

  10. Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

    International Nuclear Information System (INIS)

    You, Sung Hye; Son, Gyu Ri; Lee, Nam Joon; Suh, Sangil; Ryoo, In Seon; Seol, Hae Young; Lee, Young Hen; Seo, Hyung Suk

    2017-01-01

    The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL), for measuring the volume of parathyroid glands. Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D) and three-dimensional (3D) methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs) and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism

  11. Measuring standing balance in multiple sclerosis: Further progress towards an automatic and reliable method in clinical practice.

    Science.gov (United States)

    Keune, Philipp M; Young, William R; Paraskevopoulos, Ioannis T; Hansen, Sascha; Muenssinger, Jana; Oschmann, Patrick; Müller, Roy

    2017-08-15

    Balance deficits in multiple sclerosis (MS) are often monitored by means of observer-rated tests. These may provide reliable data, but may also be time-consuming, subject to inter-rater variability, and potentially insensitive to mild fluctuations throughout the clinical course. On the other hand, laboratory assessments are often not available. The Nintendo Wii Balance Board (WBB) may represent a low-cost solution. The purpose of the current study was to examine the methodological quality of WBB data in MS (internal consistency, test-retest reliability), convergent validity with observer-rated tests (Berg Balance Scale, BBS; Timed-Up and Go Test, TUG), and discriminative validity concerning clinical status (Expanded Disability Status Scale, EDSS). Standing balance was assessed with the WBB for 4min in 63 MS patients at two assessment points, four months apart. Additionally, patients were examined with the BBS, TUG and the EDSS. A period of 4min on the WBB provided data characterized by excellent internal consistency and test-retest reliability. Significant correlations between WBB data and results of the BBS and TUG were obtained after merely 2min on the board. An EDSS median-split revealed that higher EDSS values (>3) were associated with significantly increased postural sway on the WBB. WBB measures reflecting postural sway are methodologically robust in MS, involving excellent internal consistency and test-retest reliability. They are also characterized by convergent validity with other considerably lengthier observer-rated balance measures (BBS) and sensitive to broader clinical characteristics (EDSS). The WBB may hence represent an effective, easy-to-use monitoring tool for MS patients in clinical practice. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Comparison of reliability and responsiveness of patient-reported clinical outcome measures in knee osteoarthritis rehabilitation.

    Science.gov (United States)

    Williams, Valerie J; Piva, Sara R; Irrgang, James J; Crossley, Chad; Fitzgerald, G Kelley

    2012-08-01

    Secondary analysis, pretreatment-posttreatment observational study. To compare the reliability and responsiveness of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Knee Outcome Survey activities of daily living subscale (KOS-ADL), and the Lower Extremity Functional Scale (LEFS) in individuals with knee osteoarthritis (OA). The WOMAC is the current standard in patient-reported measures of function in patients with knee OA. The KOS-ADL and LEFS were designed for potential use in patients with knee OA. If the KOS-ADL and LEFS are to be considered viable alternatives to the WOMAC for measuring patient-reported function in individuals with knee OA, they should have measurement properties comparable to the WOMAC. It would also be important to determine whether either of these instruments may be superior to the WOMAC in terms of reliability or responsiveness in this population. Data from 168 subjects with knee OA, who participated in a rehabilitation program, were used in the analyses. Reliability and responsiveness of each outcome measure were estimated at follow-ups of 2, 6, and 12 months. Reliability was estimated by calculating the intraclass correlation coefficient (ICC2,1) for subjects who were unchanged in status from baseline at each follow-up time, based on a global rating of change score. To examine responsiveness, the standard error of the measurement, minimal detectable change, minimal clinically important difference, and the Guyatt responsiveness index were calculated for each outcome measure at each follow-up time. All 3 outcome measures demonstrated reasonable reliability and responsiveness to change. Reliability and responsiveness tended to decrease somewhat with increasing follow-up time. There were no substantial differences between outcome measures for reliability or any of the 3 measures of responsiveness at any follow-up time. The results do not indicate that one outcome measure is more reliable or responsive than

  13. Reliability centered maintenance as an optimization tool for electrical power plants

    International Nuclear Information System (INIS)

    Jacquot, J.P.; Bryla, P.; Martin-Mattei, C.; Meuwisse, C.

    1997-08-01

    Seven years ago, Electricite de France launched a Reliability Centered Maintenance (RCM) pilot project to optimize preventive maintenance for its nuclear power plants. After a feasibility study, a RCM method was standardized. It is now applied on a large scale to the 50 EDF nuclear units. A RCM workstation based on this standardized method has been developed and is now used in each plant. In the next step, it is considered whether a Risk based Approach can be included in this RCM process in order to analyze critical passive components such as pipes and supports. Considering the potential advantages of these optimization techniques, a dedicated process has been also developed for maintenance of future plants, gas turbines, or nuclear units. A survey of these different developments of methods and tools is presented. (author)

  14. Modeling reliability measurement of interface on information system: Towards the forensic of rules

    Science.gov (United States)

    Nasution, M. K. M.; Sitompul, Darwin; Harahap, Marwan

    2018-02-01

    Today almost all machines depend on the software. As a software and hardware system depends also on the rules that are the procedures for its use. If the procedure or program can be reliably characterized by involving the concept of graph, logic, and probability, then regulatory strength can also be measured accordingly. Therefore, this paper initiates an enumeration model to measure the reliability of interfaces based on the case of information systems supported by the rules of use by the relevant agencies. An enumeration model is obtained based on software reliability calculation.

  15. Reliable and valid assessment of Lichtenstein hernia repair skills.

    Science.gov (United States)

    Carlsen, C G; Lindorff-Larsen, K; Funch-Jensen, P; Lund, L; Charles, P; Konge, L

    2014-08-01

    Lichtenstein hernia repair is a common surgical procedure and one of the first procedures performed by a surgical trainee. However, formal assessment tools developed for this procedure are few and sparsely validated. The aim of this study was to determine the reliability and validity of an assessment tool designed to measure surgical skills in Lichtenstein hernia repair. Key issues were identified through a focus group interview. On this basis, an assessment tool with eight items was designed. Ten surgeons and surgical trainees were video recorded while performing Lichtenstein hernia repair, (four experts, three intermediates, and three novices). The videos were blindly and individually assessed by three raters (surgical consultants) using the assessment tool. Based on these assessments, validity and reliability were explored. The internal consistency of the items was high (Cronbach's alpha = 0.97). The inter-rater reliability was very good with an intra-class correlation coefficient (ICC) = 0.93. Generalizability analysis showed a coefficient above 0.8 even with one rater. The coefficient improved to 0.92 if three raters were used. One-way analysis of variance found a significant difference between the three groups which indicates construct validity, p fashion with the new procedure-specific assessment tool. We recommend this tool for future assessment of trainees performing Lichtenstein hernia repair to ensure that the objectives of competency-based surgical training are met.

  16. Reliability assessment for thickness measurements of pipe wall using probability of detection

    International Nuclear Information System (INIS)

    Nakamoto, Hiroyuki; Kojima, Fumio; Kato, Sho

    2013-01-01

    This paper proposes a reliability assessment method for thickness measurements of pipe wall using probability of detection (POD). Thicknesses of pipes are measured by qualified inspectors with ultrasonic thickness gauges. The inspection results are affected by human factors of the inspectors and include some errors, because the inspectors have different experiences and frequency of inspections. In order to ensure reliability for inspection results, first, POD evaluates experimental results of pipe-wall thickness inspection. We verify that the results have differences depending on inspectors including qualified inspectors. Second, two human factors that affect POD are indicated. Finally, it is confirmed that POD can identify the human factors and ensure reliability for pipe-wall thickness inspections. (author)

  17. Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements

    Directory of Open Access Journals (Sweden)

    Natalia M. Martinho

    2015-04-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the intra and inter-rater reliability of pelvic floor muscle (PFM dynamometric measurements for maximum and average strengths, as well as endurance. METHOD: A convenience sample of 18 nulliparous women, without any urogynecological complaints, aged between 19 and 31 (mean age of 25.4±3.9 participated in this study. They were evaluated using a pelvic floor dynamometer based on load cell technology. The dynamometric evaluations were repeated in three successive sessions: two on the same day with a rest period of 30 minutes between them, and the third on the following day. All participants were evaluated twice in each session; first by examiner 1 followed by examiner 2. The vaginal dynamometry data were analyzed using three parameters: maximum strength, average strength, and endurance. The Intraclass Correlation Coefficient (ICC was applied to estimate the PFM dynamometric measurement reliability, considering a good level as being above 0.75. RESULTS: The intra and inter-raters' analyses showed good reliability for maximum strength (ICCintra-rater1=0.96, ICCintra-rater2=0.95, and ICCinter-rater=0.96, average strength (ICCintra-rater1=0.96, ICCintra-rater2=0.94, and ICCinter-rater=0.97, and endurance (ICCintra-rater1=0.88, ICCintra-rater2=0.86, and ICCinter-rater=0.92 dynamometric measurements. CONCLUSIONS: The PFM dynamometric measurements showed good intra- and inter-rater reliability for maximum strength, average strength and endurance, which demonstrates that this is a reliable device that can be used in clinical practice.

  18. Can Reliability of Multiple Component Measuring Instruments Depend on Response Option Presentation Mode?

    Science.gov (United States)

    Menold, Natalja; Raykov, Tenko

    2016-01-01

    This article examines the possible dependency of composite reliability on presentation format of the elements of a multi-item measuring instrument. Using empirical data and a recent method for interval estimation of group differences in reliability, we demonstrate that the reliability of an instrument need not be the same when polarity of the…

  19. Systematic evaluation of the teaching qualities of Obstetrics and Gynecology faculty: reliability and validity of the SETQ tools

    NARCIS (Netherlands)

    van der Leeuw, Renée; Lombarts, Kiki; Heineman, Maas Jan; Arah, Onyebuchi

    2011-01-01

    The importance of effective clinical teaching for the quality of future patient care is globally understood. Due to recent changes in graduate medical education, new tools are needed to provide faculty with reliable and individualized feedback on their teaching qualities. This study validates two

  20. Validity of silhouette showcards as a measure of body size and obesity in a population in the African region: A practical research tool for general-purpose surveys.

    Science.gov (United States)

    Yepes, Maryam; Viswanathan, Barathi; Bovet, Pascal; Maurer, Jürgen

    2015-01-01

    The purpose of this study is to validate the Pulvers silhouette showcard as a measure of weight status in a population in the African region. This tool is particularly beneficial when scarce resources do not allow for direct anthropometric measurements due to limited survey time or lack of measurement technology in face-to-face general-purpose surveys or in mailed, online, or mobile device-based surveys. A cross-sectional study was conducted in the Republic of Seychelles with a sample of 1240 adults. We compared self-reported body sizes measured by Pulvers' silhouette showcards to four measurements of body size and adiposity: body mass index (BMI), body fat percent measured, waist circumference, and waist to height ratio. The accuracy of silhouettes as an obesity indicator was examined using sex-specific receiver operator curve (ROC) analysis and the reliability of this tool to detect socioeconomic gradients in obesity was compared to BMI-based measurements. Our study supports silhouette body size showcards as a valid and reliable survey tool to measure self-reported body size and adiposity in an African population. The mean correlation coefficients of self-reported silhouettes with measured BMI were 0.80 in men and 0.81 in women (P general-purpose surveys of obesity in social sciences, where limited resources do not allow for direct anthropometric measurements.

  1. Reliable Portfolio Selection Problem in Fuzzy Environment: An mλ Measure Based Approach

    Directory of Open Access Journals (Sweden)

    Yuan Feng

    2017-04-01

    Full Text Available This paper investigates a fuzzy portfolio selection problem with guaranteed reliability, in which the fuzzy variables are used to capture the uncertain returns of different securities. To effectively handle the fuzziness in a mathematical way, a new expected value operator and variance of fuzzy variables are defined based on the m λ measure that is a linear combination of the possibility measure and necessity measure to balance the pessimism and optimism in the decision-making process. To formulate the reliable portfolio selection problem, we particularly adopt the expected total return and standard variance of the total return to evaluate the reliability of the investment strategies, producing three risk-guaranteed reliable portfolio selection models. To solve the proposed models, an effective genetic algorithm is designed to generate the approximate optimal solution to the considered problem. Finally, the numerical examples are given to show the performance of the proposed models and algorithm.

  2. Test-retest reliability of behavioral measures of impulsive choice, impulsive action, and inattention.

    Science.gov (United States)

    Weafer, Jessica; Baggott, Matthew J; de Wit, Harriet

    2013-12-01

    Behavioral measures of impulsivity are widely used in substance abuse research, yet relatively little attention has been devoted to establishing their psychometric properties, especially their reliability over repeated administration. The current study examined the test-retest reliability of a battery of standardized behavioral impulsivity tasks, including measures of impulsive choice (i.e., delay discounting, probability discounting, and the Balloon Analogue Risk Task), impulsive action (i.e., the stop signal task, the go/no-go task, and commission errors on the continuous performance task), and inattention (i.e., attention lapses on a simple reaction time task and omission errors on the continuous performance task). Healthy adults (n = 128) performed the battery on two separate occasions. Reliability estimates for the individual tasks ranged from moderate to high, with Pearson correlations within the specific impulsivity domains as follows: impulsive choice (r range: .76-.89, ps reliable measures and thus can be confidently used to assess various facets of impulsivity as intermediate phenotypes for drug abuse.

  3. Relating measurement invariance, cross-level invariance, and multilevel reliability

    NARCIS (Netherlands)

    Jak, S.; Jorgensen, T.D.

    2017-01-01

    Data often have a nested, multilevel structure, for example when data are collected from children in classrooms. This kind of data complicate the evaluation of reliability and measurement invariance, because several properties can be evaluated at both the individual level and the cluster level, as

  4. TEST-RETEST RELIABILITY OF HAND GRIP STRENGTH MEASUREMENT USING A JAMAR HAND DYNAMOMETER IN PATIENTS WITH ACUTE AND CHRONIC CERVICAL RADICULOPATHY

    Directory of Open Access Journals (Sweden)

    Ejazi G

    2017-12-01

    Full Text Available Background: To evaluate the test-retest reliability of Jamar hand held dynamometer for measuring handgrip strength (HGS in patients with acute and chronic cervical radiculopathy and to find out the difference in measurement of the handgrip strength between acute and chronic cervical radiculopathy. Methods: A prospective, observational and non-experimental, the comparative study design was used. A sample of 72 subjects (37 women and 35 men suffering from cervical radiculopathy were divided into two groups i.e., Group A(acute and Group B(chronic, handgrip strength was measured using Jamar hand held dynamometer on two occasions by the same rater with an interval of 7-days. Data collection was based on standard guidelines of American Society of Hand Therapists. Three gripping trials (measured in Kg with patient’s arm in standardized arm position were recorded. The data was analyzed from the mean score obtained from the sample. Result: One-way Analysis of Variance(ANOVA was used to evaluate test-retest reliability and Tukey-Kramer Multiple Comparison Test used to find the difference between handgrip strength among acute and chronic Cervical radiculopathy cases. Greater P-value (>0.05 in both testing session, as well as 95% of the confidence interval, shows the reliability of the instrument and lesser p-value (0.05 in female subjects shows no significant difference in handgrip strength between the two groups. Conclusion: Excellent test-retest reliability for hand grip strength measurement was measured in patients with acute and chronic cervical radiculopathy shows that the equipment could be used as an assessment tool for this patient and significant difference exists among male handgrip strength between acute and chronic cervical radiculopathy cases whereas no difference exists among female handgrip strength between acute and chronic cervical radiculopathy cases.

  5. Demonstration of the test-retest reliability and sensitivity of the Lower Limb Functional Index-10 as a measure of functional recovery post burn injury: a cross-sectional repeated measures study design.

    Science.gov (United States)

    Ryland, Margaret E; Grisbrook, Tiffany L; Wood, Fiona M; Phillips, Michael; Edgar, Dale W

    2016-01-01

    Lower limb burns can significantly delay recovery of function. Measuring lower limb functional outcomes is challenging in the unique burn patient population and necessitates the use of reliable and valid tools. The aims of this study were to examine the test-retest reliability, sensitivity, and internal consistency of Sections 1 and 3 of the Lower Limb Functional Index-10 (LLFI-10) questionnaire for measuring functional ability in patients with lower limb burns over time. Twenty-nine adult patients who had sustained a lower limb burn injury in the previous 12 months completed the test-retest procedure of the study. In addition, the minimal detectable change (MDC) was calculated for Section 1 and 3 of the LLFI-10. Section 1 is focused on the activity limitations experienced by patients with a lower limb disorder whereas Section 3 involves patients indicating their current percentage of pre-injury duties. Section 1 of the LLFI-10 demonstrated excellent test-retest reliability (intra-class correlation coefficient (ICC) 0.98, 95 % CI 0.96-0.99) whilst Section 3 demonstrated high test-retest reliability (ICC 0.88, 95 % CI 0.79-0.94). MDC scores for Sections 1 and 3 were 1.27 points and 30.22 %, respectively. Internal consistency was demonstrated with a significant negative association (r s  = -0.83) between Sections 1 and 3 of the LLFI-10 (p reliable for measuring functional ability in patients who have sustained lower limb burns in the previous 12 months, and furthermore, Section 1 is sensitive to changes in patient function over time.

  6. Anatomy education environment measurement inventory: A valid tool to measure the anatomy learning environment.

    Science.gov (United States)

    Hadie, Siti Nurma Hanim; Hassan, Asma'; Ismail, Zul Izhar Mohd; Asari, Mohd Asnizam; Khan, Aaijaz Ahmed; Kasim, Fazlina; Yusof, Nurul Aiman Mohd; Manan Sulong, Husnaida Abdul; Tg Muda, Tg Fatimah Murniwati; Arifin, Wan Nor; Yusoff, Muhamad Saiful Bahri

    2017-09-01

    Students' perceptions of the education environment influence their learning. Ever since the major medical curriculum reform, anatomy education has undergone several changes in terms of its curriculum, teaching modalities, learning resources, and assessment methods. By measuring students' perceptions concerning anatomy education environment, valuable information can be obtained to facilitate improvements in teaching and learning. Hence, it is important to use a valid inventory that specifically measures attributes of the anatomy education environment. In this study, a new 11-factor, 132-items Anatomy Education Environment Measurement Inventory (AEEMI) was developed using Delphi technique and was validated in a Malaysian public medical school. The inventory was found to have satisfactory content evidence (scale-level content validity index [total] = 0.646); good response process evidence (scale-level face validity index [total] = 0.867); and acceptable to high internal consistency, with the Raykov composite reliability estimates of the six factors are in the range of 0.604-0.876. The best fit model of the AEEMI is achieved with six domains and 25 items (X 2  = 415.67, P education environment in Malaysia. A concerted collaboration should be initiated toward developing a valid universal tool that, using the methods outlined in this study, measures the anatomy education environment across different institutions and countries. Anat Sci Educ 10: 423-432. © 2017 American Association of Anatomists. © 2017 American Association of Anatomists.

  7. Development, reliability and use of a food environment assessment tool in supermarkets of four neighbourhoods in Montréal, Canada

    Directory of Open Access Journals (Sweden)

    Élise Jalbert-Arsenault

    2017-09-01

    Full Text Available Introduction: The food environment is a promising arena in which to influence people’s dietary habits. This study aimed to develop a comprehensive food environment assessment tool for businesses and characterize the food environment of a low-tomedium income area of Montréal, Canada. Methods: We developed a tool, Mesure de l’environnement alimentaire du consommateur dans les supermarchés (MEAC-S, and tested it for reliability. We used the MEAC-S to assess the consumer food environment of 17 supermarkets in four neighbourhoods of Montréal. We measured the shelf length, variety, price, display counts and in-store positions of fruits and vegetables (FV and ultra-processed food products (UPFPs. We also assessed fresh FV for quality. Store size was estimated using the total measured shelf length for all food categories. We conducted Spearman correlations between these indicators of the food environment. Results: Reliability analyses revealed satisfactory results for most indicators. Characterization of the food environment revealed high variability in shelf length, variety and price of FV between supermarkets and suggested a disproportionate promotion of UPFPs. Display counts of UPFPs outside their normal display location ranged from 7 to 26, and they occupied 8 to 33 strategic in-store positions, whereas the number of display counts of fresh FV outside their normal display location exceeded 1 in only 2 of the 17 stores surveyed, and they occupied a maximum of 2 strategic in-store positions per supermarket. Price of UPFPs was inversely associated with their prominence (p $lt .005 and promotion (p $lt .003. Store size was associated with display counts and strategic in-store positioning of UPFPs (p $lt .001, but not FV, and was inversely associated with the price of soft drinks (p $lt .003. Conclusion: This study illustrates the variability of the food environment between supermarkets and underscores the importance of measuring in

  8. Indicators and Measurement Tools for Health Systems Integration: A Knowledge Synthesis

    Directory of Open Access Journals (Sweden)

    Esther Suter

    2017-11-01

    Full Text Available Background: Despite far reaching support for integrated care, conceptualizing and measuring integrated care remains challenging. This knowledge synthesis aimed to identify indicator domains and tools to measure progress towards integrated care. Methods: We used an established framework and a Delphi survey with integration experts to identify relevant measurement domains. For each domain, we searched and reviewed the literature for relevant tools. Findings: From 7,133 abstracts, we retrieved 114 unique tools. We found many quality tools to measure care coordination, patient engagement and team effectiveness/performance. In contrast, there were few tools in the domains of performance measurement and information systems, alignment of organizational goals and resource allocation. The search yielded 12 tools that measure overall integration or three or more indicator domains. Discussion: Our findings highlight a continued gap in tools to measure foundational components that support integrated care. In the absence of such targeted tools, “overall integration” tools may be useful for a broad assessment of the overall state of a system. Conclusions: Continued progress towards integrated care depends on our ability to evaluate the success of strategies across different levels and context. This study has identified 114 tools that measure integrated care across 16 domains, supporting efforts towards a unified measurement framework.

  9. Indicators and Measurement Tools for Health Systems Integration: A Knowledge Synthesis

    Science.gov (United States)

    Oelke, Nelly D.; da Silva Lima, Maria Alice Dias; Stiphout, Michelle; Janke, Robert; Witt, Regina Rigatto; Van Vliet-Brown, Cheryl; Schill, Kaela; Rostami, Mahnoush; Hepp, Shelanne; Birney, Arden; Al-Roubaiai, Fatima; Marques, Giselda Quintana

    2017-01-01

    Background: Despite far reaching support for integrated care, conceptualizing and measuring integrated care remains challenging. This knowledge synthesis aimed to identify indicator domains and tools to measure progress towards integrated care. Methods: We used an established framework and a Delphi survey with integration experts to identify relevant measurement domains. For each domain, we searched and reviewed the literature for relevant tools. Findings: From 7,133 abstracts, we retrieved 114 unique tools. We found many quality tools to measure care coordination, patient engagement and team effectiveness/performance. In contrast, there were few tools in the domains of performance measurement and information systems, alignment of organizational goals and resource allocation. The search yielded 12 tools that measure overall integration or three or more indicator domains. Discussion: Our findings highlight a continued gap in tools to measure foundational components that support integrated care. In the absence of such targeted tools, “overall integration” tools may be useful for a broad assessment of the overall state of a system. Conclusions: Continued progress towards integrated care depends on our ability to evaluate the success of strategies across different levels and context. This study has identified 114 tools that measure integrated care across 16 domains, supporting efforts towards a unified measurement framework. PMID:29588637

  10. Reliability and Minimum Detectable Change of Temporal-Spatial, Kinematic, and Dynamic Stability Measures during Perturbed Gait.

    Directory of Open Access Journals (Sweden)

    Christopher A Rábago

    Full Text Available Temporal-spatial, kinematic variability, and dynamic stability measures collected during perturbation-based assessment paradigms are often used to identify dysfunction associated with gait instability. However, it remains unclear which measures are most reliable for detecting and tracking responses to perturbations. This study systematically determined the between-session reliability and minimum detectable change values of temporal-spatial, kinematic variability, and dynamic stability measures during three types of perturbed gait. Twenty young healthy adults completed two identical testing sessions two weeks apart, comprised of an unperturbed and three perturbed (cognitive, physical, and visual walking conditions in a virtual reality environment. Within each session, perturbation responses were compared to unperturbed walking using paired t-tests. Between-session reliability and minimum detectable change values were also calculated for each measure and condition. All temporal-spatial, kinematic variability and dynamic stability measures demonstrated fair to excellent between-session reliability. Minimal detectable change values, normalized to mean values ranged from 1-50%. Step width mean and variability measures demonstrated the greatest response to perturbations with excellent between-session reliability and low minimum detectable change values. Orbital stability measures demonstrated specificity to perturbation direction and sensitivity with excellent between-session reliability and low minimum detectable change values. We observed substantially greater between-session reliability and lower minimum detectable change values for local stability measures than previously described which may be the result of averaging across trials within a session and using velocity versus acceleration data for reconstruction of state spaces. Across all perturbation types, temporal-spatial, orbital and local measures were the most reliable measures with the

  11. Measuring walking within and outside the neighborhood in Chinese elders: reliability and validity

    Directory of Open Access Journals (Sweden)

    Cerin Ester

    2011-11-01

    Full Text Available Abstract Background Walking is a preferred, prevalent and recommended activity for aging populations and is influenced by the neighborhood built environment. To study this influence it is necessary to differentiate whether walking occurs within or outside of the neighborhood. The Neighborhood Physical Activity Questionnaire (NPAQ collects information on setting-specific physical activity, including walking, inside and outside one's neighborhood. While the NPAQ has shown to be a reliable measure in adults, its reliability in older adults is unknown. Additionally its validity and the influence of type of neighborhood on reliability and validity have yet to be explored. Methods The NPAQ walking component was adapted for Chinese speaking elders (NWQ-CS. Ninety-six Chinese elders, stratified by social economic status and neighborhood walkability, wore an accelerometer and completed a log of walks for 7 days. Following the collection of valid data the NWQ-CS was interviewer-administered. Fourteen to 20 days (average of 17 days later the NWQ-CS was re-administered. Test-retest reliability and validity of the NWQ-CS were assessed. Results Reliability and validity estimates did not differ with type of neighborhood. NWQ-CS measures of walking showed moderate to excellent reliability. Reliability was generally higher for estimates of weekly frequency than minutes of walking. Total weekly minutes of walking were moderately related to all accelerometry measures. Moderate-to-strong associations were found between the NWQ-CS and log-of-walks variables. The NWQ-CS yielded statistically significantly lower mean values of total walking, weekly minutes of walking for transportation and weekly frequency of walking for transportation outside the neighborhood than the log-of-walks. Conclusions The NWQ-CS showed measurement invariance across types of neighborhoods. It is a valid measure of walking for recreation and frequency of walking for transport. However, it may

  12. Development of Cognitive Bias Modification (CBM) Tools to Promote Adjustment During Reintegration Following Deployment

    Science.gov (United States)

    2016-11-01

    14. ABSTRACT The overarching goal of the grant is to develop valid and reliable computerized tools to measure and modify anger-related cognitive...plasticity in threat processing may confer risk for military performance and psychological adjustment both in theatre and upon reintegration back to...civilian environments. The overarching goal of the current grant is to develop valid and reliable computerized tools to measure and modify anger

  13. Techniques, processes, and measures for software safety and reliability

    International Nuclear Information System (INIS)

    Sparkman, D.

    1992-01-01

    The purpose of this report is to provide a detailed survey of current recommended practices and measurement techniques for the development of reliable and safe software-based systems. This report is intended to assist the United States Nuclear Reaction Regulation (NRR) in determining the importance and maturity of the available techniques and in assessing the relevance of individual standards for application to instrumentation and control systems in nuclear power generating stations. Lawrence Livermore National Laboratory (LLNL) provides technical support for the Instrumentation and Control System Branch (ICSB) of NRRin advanced instrumentation and control systems, distributed digital systems, software reliability, and the application of verificafion and validafion for the development of software

  14. Teamwork Assessment Tools in Obstetric Emergencies: A Systematic Review.

    Science.gov (United States)

    Onwochei, Desire N; Halpern, Stephen; Balki, Mrinalini

    2017-06-01

    Team-based training and simulation can improve patient safety, by improving communication, decision making, and performance of team members. Currently, there is no general consensus on whether or not a specific assessment tool is better adapted to evaluate teamwork in obstetric emergencies. The purpose of this qualitative systematic review was to find the tools available to assess team effectiveness in obstetric emergencies. We searched Embase, Medline, PubMed, Web of Science, PsycINFO, CINAHL, and Google Scholar for prospective studies that evaluated nontechnical skills in multidisciplinary teams involving obstetric emergencies. The search included studies from 1944 until January 11, 2016. Data on reliability and validity measures were collected and used for interpretation. A descriptive analysis was performed on the data. Thirteen studies were included in the final qualitative synthesis. All the studies assessed teams in the context of obstetric simulation scenarios, but only six included anesthetists in the simulations. One study evaluated their teamwork tool using just validity measures, five using just reliability measures, and one used both. The most reliable tools identified were the Clinical Teamwork Scale, the Global Assessment of Obstetric Team Performance, and the Global Rating Scale of performance. However, they were still lacking in terms of quality and validity. More work needs to be conducted to establish the validity of teamwork tools for nontechnical skills, and the development of an ideal tool is warranted. Further studies are required to assess how outcomes, such as performance and patient safety, are influenced when using these tools.

  15. Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer.

    Science.gov (United States)

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-01-01

    To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.

  16. Developing a tool to measure health worker motivation in district hospitals in Kenya

    Directory of Open Access Journals (Sweden)

    Gilson Lucy

    2009-05-01

    Full Text Available Abstract Background We wanted to try to account for worker motivation as a key factor that might affect the success of an intervention to improve implementation of health worker practices in eight district hospitals in Kenya. In the absence of available tools, we therefore aimed to develop a tool that could enable a rapid measurement of motivation at baseline and at subsequent points during the 18-month intervention study. Methods After a literature review, a self-administered questionnaire was developed to assess the outcomes and determinants of motivation of Kenyan government hospital staff. The initial questionnaire included 23 questions (from seven underlying constructs related to motivational outcomes that were then used to construct a simpler tool to measure motivation. Parallel qualitative work was undertaken to assess the relevance of the questions chosen and the face validity of the tool. Results Six hundred eighty-four health workers completed the questionnaires at baseline. Reliability analysis and factor analysis were used to produce the simplified motivational index, which consisted of 10 equally-weighted items from three underlying factors. Scores on the 10-item index were closely correlated with scores for the 23-item index, indicating that in future rapid assessments might be based on the 10 questions alone. The 10-item motivation index was also able to identify statistically significant differences in mean health worker motivation scores between the study hospitals (p Conclusion The 10-item score developed may be useful to monitor changes in motivation over time within our study or be used for more extensive rapid assessments of health worker motivation in Kenya.

  17. Inter-rater and intra-rater reliability of a clinical protocol for measuring turnout in collegiate dancers.

    Science.gov (United States)

    Greene, Amanda; Lasner, Andrea; Deu, Rajwinder; Oliphant, Seth; Johnson, Kenneth

    2018-02-02

    Reliable methods of measuring turnout in dancers and comparing active turnout (used in class) with functional (uncompensated) turnout are needed. Authors have suggested measurement techniques but there is no clinically useful, easily reproducible technique with established inter-rater and intra-rater reliability. We adapted a technique based on previous research, which is easily reproducible. We hypothesized excellent inter-rater and intra-rater reliability between experienced physical therapists (PTs) and a briefly trained faculty member from a university's department of dance. Thirty-two participants were recruited from the same dance department. Dancers' active and functional turnout was measured by each rater. We found that our technique for measuring active and functional turnout has excellent inter-rater and intra-rater reliability when performed by two experienced PTs and by one briefly trained university-level dance faculty member. For active turnout, inter-rater reliability was 0.78 among all raters and 0.82 among only the PT raters; intra-rater reliability was 0.82 among all raters and 0.85 among only the PT raters. For functional turnout, inter-rater reliability was 0.86 among all raters and 0.88 among only the PT raters; intra-rater reliability was 0.87 among all raters and 0.88 among only the PT raters. The measurement technique described provides a standardized protocol with excellent inter-rater and intra-rater reliability when performed by experienced PTs or by a briefly trained university-level dance faculty member.

  18. Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

    Directory of Open Access Journals (Sweden)

    Sung-Hye You

    2017-01-01

    Full Text Available Purpose The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL, for measuring the volume of parathyroid glands. Methods Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D and three-dimensional (3D methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. Results The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. Conclusion The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism.

  19. Reliability and Validity of the Work and Well-Being Inventory (WBI) for Employees.

    Science.gov (United States)

    Vendrig, A A; Schaafsma, F G

    2018-06-01

    Purpose The purpose of this study is to measure the psychometric properties of the Work and Wellbeing Inventory (WBI) (in Dutch: VAR-2), a screening tool that is used within occupational health care and rehabilitation. Our research question focused on the reliability and validity of this inventory. Methods Over the years seven different samples of workers, patients and sick listed workers varying in size between 89 and 912 participants (total: 2514), were used to measure the test-retest reliability, the internal consistency, the construct and concurrent validity, and the criterion and predictive validity. Results The 13 scales displayed good internal consistency and test-retest reliability. The constructive validity of the WBI could clearly be demonstrated in both patients and healthy workers. Confirmative factor analyses revealed a CFI >.90 for all scales. The depression scale predicted future work absenteeism (>6 weeks) because of a common mental disorder in healthy workers. The job strain scale and the illness behavior scale predicted long term absenteeism (>3 months) in workers with short-term absenteeism. The illness behavior scale moderately predicted return to work in rehab patients attending an intensive multidisciplinary program. Conclusions The WBI is a valid and reliable tool for occupational health practitioners to screen for risk factors for prolonged or future sickness absence. With this tool they will have reliable indications for further advice and interventions to restore the work ability.

  20. Reliability of Phase Velocity Measurements of Flexural Acoustic Waves in the Human Tibia In-Vivo.

    Science.gov (United States)

    Vogl, Florian; Schnüriger, Karin; Gerber, Hans; Taylor, William R

    2016-01-01

    Axial-transmission acoustics have shown to be a promising technique to measure individual bone properties and detect bone pathologies. With the ultimate goal being the in-vivo application of such systems, quantification of the key aspects governing the reliability is crucial to bring this method towards clinical use. This work presents a systematic reliability study quantifying the sources of variability and their magnitudes of in-vivo measurements using axial-transmission acoustics. 42 healthy subjects were measured by an experienced operator twice per week, over a four-month period, resulting in over 150000 wave measurements. In a complementary study to assess the influence of different operators performing the measurements, 10 novice operators were trained, and each measured 5 subjects on a single occasion, using the same measurement protocol as in the first part of the study. The estimated standard error for the measurement protocol used to collect the study data was ∼ 17 m/s (∼ 4% of the grand mean) and the index of dependability, as a measure of reliability, was Φ = 0.81. It was shown that the method is suitable for multi-operator use and that the reliability can be improved efficiently by additional measurements with device repositioning, while additional measurements without repositioning cannot improve the reliability substantially. Phase velocity values were found to be significantly higher in males than in females (p < 10-5) and an intra-class correlation coefficient of r = 0.70 was found between the legs of each subject. The high reliability of this non-invasive approach and its intrinsic sensitivity to mechanical properties opens perspectives for the rapid and inexpensive clinical assessment of bone pathologies, as well as for monitoring programmes without any radiation exposure for the patient.

  1. Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength.

    Science.gov (United States)

    Douma, K W; Regterschot, G R H; Krijnen, W P; Slager, G E C; van der Schans, C P; Zijlstra, W

    2016-01-01

    The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various degrees of extension. Measurements between 110 and 130° extension present the highest values and the most significant increase after training. The objective of this study is to determine the test-retest reliability of muscle strength measurements by the Q Force in older adults in 110° extension. Forty-one healthy older adults, 13 males and 28 females were included in the study. Mean (SD) age was 81.9 (4.89) years. Isometric muscle strength of the Quadriceps muscle was assessed with the Q Force at 110° of knee extension. Participants were measured at two sessions with a three to eight day interval between sessions. To determine relative reliability, the intraclass correlation coefficient (ICC) was calculated. To determine absolute reliability, Bland and Altman Limits of Agreement (LOA) were calculated and t-tests were performed. Relative reliability of the Q Force is good to excellent as all ICC coefficients are higher than 0.75. Generally a large 95 % LOA, reflecting only moderate absolute reliability, is found as exemplified for the peak torque left leg of -18.6 N to 33.8 N and the right leg of -9.2 N to 26.4 N was between 15.7 and 23.6 Newton representing 25.2 % to 39.9 % of the size of the mean. Small systematic differences in mean were found between measurement session 1 and 2. The present study shows that the Q Force has excellent relative test-retest reliability, but limited absolute test-retest reliability. Since the Q Force is relatively cheap and mobile it is suitable for

  2. Interrater Reliability of mHealth App Rating Measures: Analysis of Top Depression and Smoking Cessation Apps.

    Science.gov (United States)

    Powell, Adam C; Torous, John; Chan, Steven; Raynor, Geoffrey Stephen; Shwarts, Erik; Shanahan, Meghan; Landman, Adam B

    2016-02-10

    There are over 165,000 mHealth apps currently available to patients, but few have undergone an external quality review. Furthermore, no standardized review method exists, and little has been done to examine the consistency of the evaluation systems themselves. We sought to determine which measures for evaluating the quality of mHealth apps have the greatest interrater reliability. We identified 22 measures for evaluating the quality of apps from the literature. A panel of 6 reviewers reviewed the top 10 depression apps and 10 smoking cessation apps from the Apple iTunes App Store on these measures. Krippendorff's alpha was calculated for each of the measures and reported by app category and in aggregate. The measure for interactiveness and feedback was found to have the greatest overall interrater reliability (alpha=.69). Presence of password protection (alpha=.65), whether the app was uploaded by a health care agency (alpha=.63), the number of consumer ratings (alpha=.59), and several other measures had moderate interrater reliability (alphas>.5). There was the least agreement over whether apps had errors or performance issues (alpha=.15), stated advertising policies (alpha=.16), and were easy to use (alpha=.18). There were substantial differences in the interrater reliabilities of a number of measures when they were applied to depression versus smoking apps. We found wide variation in the interrater reliability of measures used to evaluate apps, and some measures are more robust across categories of apps than others. The measures with the highest degree of interrater reliability tended to be those that involved the least rater discretion. Clinical quality measures such as effectiveness, ease of use, and performance had relatively poor interrater reliability. Subsequent research is needed to determine consistent means for evaluating the performance of apps. Patients and clinicians should consider conducting their own assessments of apps, in conjunction with

  3. Development and validation of a short form of the self-efficacy measurement tool for Iranian patients with myocardial infarction

    Directory of Open Access Journals (Sweden)

    Soleiman Zand

    2017-09-01

    Full Text Available To assess efficacy in patients with heart failure need to have a scientific tool based on psychometric features is evident. The researchers developed a scientific tool based on psychometric principles for assessing self-efficacy beliefs in patients with Myocardial Infarction (MI as the only tool of its kind; however, Due to the large number of questions in the questionnaire, respondents may not desire to complete it accuracy. The present study was conducted to develop and validate a short form of this tool. This study was conducted on a sample of 311 patients diagnosed with MI by a cardiologist and selected through convenience sampling. The 80-20 rule was used for evaluating the 60 items of the short-form MI Self-Efficacy Measurement Tool (SF-SEMT and for eliminating items without an adequate sensitivity and accuracy. The factor analysis revealed 5 factors that explained a total of 87.92% the variance; the kaiser-meyer-olkin index was calculated as 0.915 with a probable significance level of 0.001. A total of 22 items and 5 factors were extracted for this short-form tool. The reliability of the tool was confirmed with Cronbach’s alpha coefficients of 0.96 to 0.97 for the factors and 0.97 for the entire tool. The short-form MI self-efficacy measurement tool has better psychometric features than the original long form, as the former was found to have a better factor structure compared to the latter

  4. Reliability and accuracy analysis of a new semiautomatic radiographic measurement software in adult scoliosis.

    Science.gov (United States)

    Aubin, Carl-Eric; Bellefleur, Christian; Joncas, Julie; de Lanauze, Dominic; Kadoury, Samuel; Blanke, Kathy; Parent, Stefan; Labelle, Hubert

    2011-05-20

    Radiographic software measurement analysis in adult scoliosis. To assess the accuracy as well as the intra- and interobserver reliability of measuring different indices on preoperative adult scoliosis radiographs using a novel measurement software that includes a calibration procedure and semiautomatic features to facilitate the measurement process. Scoliosis requires a careful radiographic evaluation to assess the deformity. Manual and computer radiographic process measures have been studied extensively to determine the reliability and reproducibility in adolescent idiopathic scoliosis. Most studies rely on comparing given measurements, which are repeated by the same user or by an expert user. A given measure with a small intra- or interobserver error might be deemed as good repeatability, but all measurements might not be truly accurate because the ground-truth value is often unknown. Thorough accuracy assessment of radiographic measures is necessary to assess scoliotic deformities, compare these measures at different stages or to permit valid multicenter studies. Thirty-four sets of adult scoliosis digital radiographs were measured two times by three independent observers using a novel radiographic measurement software that includes semiautomatic features to facilitate the measurement process. Twenty different measures taken from the Spinal Deformity Study Group radiographic measurement manual were performed on the coronal and sagittal images. Intra- and intermeasurer reliability for each measure was assessed. The accuracy of the measurement software was also assessed using a physical spine model in six different scoliotic configurations as a true reference. The majority of the measures demonstrated good to excellent intra- and intermeasurer reliability, except for sacral obliquity. The standard variation of all the measures was very small: ≤ 4.2° for Cobb angles, ≤ 4.2° for the kyphosis, ≤ 5.7° for the lordosis, ≤ 3.9° for the pelvic angles, and

  5. Image based method for aberration measurement of lithographic tools

    Science.gov (United States)

    Xu, Shuang; Tao, Bo; Guo, Yongxing; Li, Gongfa

    2018-01-01

    Information of lens aberration of lithographic tools is important as it directly affects the intensity distribution in the image plane. Zernike polynomials are commonly used for a mathematical description of lens aberrations. Due to the advantage of lower cost and easier implementation of tools, image based measurement techniques have been widely used. Lithographic tools are typically partially coherent systems that can be described by a bilinear model, which entails time consuming calculations and does not lend a simple and intuitive relationship between lens aberrations and the resulted images. Previous methods for retrieving lens aberrations in such partially coherent systems involve through-focus image measurements and time-consuming iterative algorithms. In this work, we propose a method for aberration measurement in lithographic tools, which only requires measuring two images of intensity distribution. Two linear formulations are derived in matrix forms that directly relate the measured images to the unknown Zernike coefficients. Consequently, an efficient non-iterative solution is obtained.

  6. Reliability and validity of a tool to measure the severity of tongue thrust in children: the Tongue Thrust Rating Scale.

    Science.gov (United States)

    Serel Arslan, S; Demir, N; Karaduman, A A

    2017-02-01

    This study aimed to develop a scale called Tongue Thrust Rating Scale (TTRS), which categorised tongue thrust in children in terms of its severity during swallowing, and to investigate its validity and reliability. The study describes the developmental phase of the TTRS and presented its content and criterion-based validity and interobserver and intra-observer reliability. For content validation, seven experts assessed the steps in the scale over two Delphi rounds. Two physical therapists evaluated videos of 50 children with cerebral palsy (mean age, 57·9 ± 16·8 months), using the TTRS to test criterion-based validity, interobserver and intra-observer reliability. The Karaduman Chewing Performance Scale (KCPS) and Drooling Severity and Frequency Scale (DSFS) were used for criterion-based validity. All the TTRS steps were deemed necessary. The content validity index was 0·857. A very strong positive correlation was found between two examinations by one physical therapist, which indicated intra-observer reliability (r = 0·938, P reliability (r = 0·892, P validity of the TTRS. The TTRS is a valid, reliable and clinically easy-to-use functional instrument to document the severity of tongue thrust in children. © 2016 John Wiley & Sons Ltd.

  7. [The reliability of a questionnaire regarding Colombian children's physical activity].

    Science.gov (United States)

    Herazo-Beltrán, Aliz Y; Domínguez-Anaya, Regina

    2012-10-01

    Reporting the Physical Activity Questionnaire for school children's (PAQ-C) test-retest reliability and internal consistency. This was a descriptive study of 100 school-aged children aged 9 to 11 years old attending a school in Cartagena, Colombia. The sample was randomly selected. The PAQ-C was given twice, one week apart, after the informed consent forms had been signing by the children's parents and school officials. Cronbach's alpha coefficient of reliability was used for assessing internal consistency and an intra-class correlation coefficient for test-retest reliability SPSS (version 17.0) was used for statistical analysis. The questionnaire scored 0.73 internal consistencies during the first measurement and 0.78 on the second; intra-class correlation coefficient was 0.60. There were differences between boys and girls regarding both measurements. The PAQ-C had acceptable internal consistency and test-retest reliability, thereby making it useful for measuring children's self-reported physical activity and a valuable tool for population studies in Colombia.

  8. Influence of Contrast Media on Bone Mineral Density (BMD) Measurements from Routine Contrast-Enhanced MDCT Datasets using a Phantom-less BMD Measurement Tool.

    Science.gov (United States)

    Toelly, Andrea; Bardach, Constanze; Weber, Michael; Gong, Rui; Lai, Yanbo; Wang, Pei; Guo, Yulin; Kirschke, Jan; Baum, Thomas; Gruber, Michael

    2017-06-01

    Aim  To evaluate the differences in phantom-less bone mineral density (BMD) measurements in contrast-enhanced routine MDCT scans at different contrast phases, and to develop an algorithm for calculating a reliable BMD value. Materials and Methods  112 postmenopausal women from the age of 40 to 77 years (mean age: 57.31 years; SD 9.61) who underwent a clinically indicated MDCT scan, consisting of an unenhanced, an arterial, and a venous phase, were included. A retrospective analysis of the BMD values of the Th12 to L4 vertebrae in each phase was performed using a commercially available phantom-less measurement tool. Results  The mean BMD value in the unenhanced MDCT scans was 79.76 mg/cm³ (SD 31.20), in the arterial phase it was 85.09 mg/cm³ (SD 31.61), and in the venous phase it was 86.18 mg/cm³ (SD 31.30). A significant difference (p Influence of Contrast Media on Bone Mineral Density (BMD) Measurements from Routine Contrast-Enhanced MDCT Datasets using a Phantom-less BMD Measurement Tool. Fortschr Röntgenstr 2017; 189: 537 - 543. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Accuracy and Reliability of the Kinect Version 2 for Clinical Measurement of Motor Function.

    Directory of Open Access Journals (Sweden)

    Karen Otte

    Full Text Available The introduction of low cost optical 3D motion tracking sensors provides new options for effective quantification of motor dysfunction.The present study aimed to evaluate the Kinect V2 sensor against a gold standard motion capture system with respect to accuracy of tracked landmark movements and accuracy and repeatability of derived clinical parameters.Nineteen healthy subjects were concurrently recorded with a Kinect V2 sensor and an optical motion tracking system (Vicon. Six different movement tasks were recorded with 3D full-body kinematics from both systems. Tasks included walking in different conditions, balance and adaptive postural control. After temporal and spatial alignment, agreement of movements signals was described by Pearson's correlation coefficient and signal to noise ratios per dimension. From these movement signals, 45 clinical parameters were calculated, including ranges of motions, torso sway, movement velocities and cadence. Accuracy of parameters was described as absolute agreement, consistency agreement and limits of agreement. Intra-session reliability of 3 to 5 measurement repetitions was described as repeatability coefficient and standard error of measurement for each system.Accuracy of Kinect V2 landmark movements was moderate to excellent and depended on movement dimension, landmark location and performed task. Signal to noise ratio provided information about Kinect V2 landmark stability and indicated larger noise behaviour in feet and ankles. Most of the derived clinical parameters showed good to excellent absolute agreement (30 parameters showed ICC(3,1 > 0.7 and consistency (38 parameters showed r > 0.7 between both systems.Given that this system is low-cost, portable and does not require any sensors to be attached to the body, it could provide numerous advantages when compared to established marker- or wearable sensor based system. The Kinect V2 has the potential to be used as a reliable and valid clinical

  10. The validity and reliability of the four square step test in different adult populations: a systematic review.

    Science.gov (United States)

    Moore, Martha; Barker, Karen

    2017-09-11

    The four square step test (FSST) was first validated in healthy older adults to provide a measure of dynamic standing balance and mobility. The FSST has since been used in a variety of patient populations. The purpose of this systematic review is to determine the validity and reliability of the FSST in these different adult patient populations. The literature search was conducted to highlight all the studies that measured validity and reliability of the FSST. Six electronic databases were searched including AMED, CINAHL, MEDLINE, PEDro, Web of Science and Google Scholar. Grey literature was also searched for any documents relevant to the review. Two independent reviewers carried out study selection and quality assessment. The methodological quality was assessed using the QUADAS-2 tool, which is a validated tool for the quality assessment of diagnostic accuracy studies, and the COSMIN four-point checklist, which contains standards for evaluating reliability studies on the measurement properties of health instruments. Fifteen studies were reviewed studying community-dwelling older adults, Parkinson's disease, Huntington's disease, multiple sclerosis, vestibular disorders, post stroke, post unilateral transtibial amputation, knee pain and hip osteoarthritis. Three of the studies were of moderate methodological quality scoring low in risk of bias and applicability for all domains in the QUADAS-2 tool. Three studies scored "fair" on the COSMIN four-point checklist for the reliability components. The concurrent validity of the FSST was measured in nine of the studies with moderate to strong correlations being found. Excellent Intraclass Correlation Coefficients were found between physiotherapists carrying out the tests (ICC = .99) with good to excellent test-retest reliability shown in nine of the studies (ICC = .73-.98). The FSST may be an effective and valid tool for measuring dynamic balance and a participants' falls risk. It has been shown to have strong

  11. Feasibility and Inter-Rater Reliability of Physical Performance Measures in Acutely Admitted Older Medical Patients

    DEFF Research Database (Denmark)

    Bodilsen, Ann Christine; Juul-Larsen, Helle Gybel; Petersen, Janne

    2015-01-01

    OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter-rater reliabi......OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter......-rater reliability of four simple measures of physical performance in acutely admitted older medical patients. DESIGN: During the first 24 hours of hospitalization, the following were assessed twice by different raters in 52 (≥ 65 years) patients admitted for acute medical illness: isometric hand grip strength, 4......, and 30-s chair stand were 8%, 7%, and 18%, and the SRD95% values were 22%, 17%, and 49%. CONCLUSION: In acutely admitted older medical patients, grip strength, gait speed, and the Cumulated Ambulation Score measurements were feasible and showed high inter-rater reliability when administered by different...

  12. Measuring attitudes towards the dying process: A systematic review of tools.

    Science.gov (United States)

    Groebe, Bernadette; Strupp, Julia; Eisenmann, Yvonne; Schmidt, Holger; Schlomann, Anna; Rietz, Christian; Voltz, Raymond

    2018-04-01

    At the end of life, anxious attitudes concerning the dying process are common in patients in Palliative Care. Measurement tools can identify vulnerabilities, resources and the need for subsequent treatment to relieve suffering and support well-being. To systematically review available tools measuring attitudes towards dying, their operationalization, the method of measurement and the methodological quality including generalizability to different contexts. Systematic review according to the PRISMA Statement. Methodological quality of tools assessed by standardized review criteria. MEDLINE, PsycINFO, PsyndexTests and the Health and Psychosocial Instruments were searched from their inception to April 2017. A total of 94 identified studies reported the development and/or validation of 44 tools. Of these, 37 were questionnaires and 7 alternative measurement methods (e.g. projective measures). In 34 of 37 questionnaires, the emotional evaluation (e.g. anxiety) towards dying is measured. Dying is operationalized in general items ( n = 20), in several specific aspects of dying ( n = 34) and as dying of others ( n = 14). Methodological quality of tools was reported inconsistently. Nine tools reported good internal consistency. Of 37 tools, 4 were validated in a clinical sample (e.g. terminal cancer; Huntington disease), indicating questionable generalizability to clinical contexts for most tools. Many tools exist to measure attitudes towards the dying process using different endpoints. This overview can serve as decision framework on which tool to apply in which contexts. For clinical application, only few tools were available. Further validation of existing tools and potential alternative methods in various populations is needed.

  13. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 2. Technical Report #1201

    Science.gov (United States)

    Lai, Cheng-Fei; Irvin, P. Shawn; Alonzo, Julie; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the second-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  14. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 3. Technical Report #1202

    Science.gov (United States)

    Lai, Cheng-Fei; Irvin, P. Shawn; Park, Bitnara Jasmine; Alonzo, Julie; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the third-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  15. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 5. Technical Report #1204

    Science.gov (United States)

    Park, Bitnara Jasmine; Irvin, P. Shawn; Lai, Cheng-Fei; Alonzo, Julie; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the fifth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  16. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 4. Technical Report #1203

    Science.gov (United States)

    Park, Bitnara Jasmine; Irvin, P. Shawn; Alonzo, Julie; Lai, Cheng-Fei; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the fourth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  17. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 6. Technical Report #1205

    Science.gov (United States)

    Irvin, P. Shawn; Alonzo, Julie; Park, Bitnara Jasmine; Lai, Cheng-Fei; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the sixth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  18. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 7. Technical Report #1206

    Science.gov (United States)

    Irvin, P. Shawn; Alonzo, Julie; Lai, Cheng-Fei; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the seventh-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  19. Confiabilidade de medidas volumétricas de estruturas temporais mesiais Reliability of mesial temporal lobe volumetric measures

    Directory of Open Access Journals (Sweden)

    Renato L. Marchetti

    2002-06-01

    Full Text Available MOTIVO DO ESTUDO: O desenvolvimento de técnicas confiáveis para a realização de medidas volumétricas de estruturas temporais mesiais (amígdala, hipocampo e giro para-hipocampal em exames de ressonância magnética (RM pode fornecer dados para o estudo de vários transtornos neuropsiquiátricos, particularmente epilepsia do lobo temporal, doença de Alzheimer e esquizofrenia. MÉTODO: Investigamos essas técnicas realizando estudo de confiabilidade intra-observador (IO e entre-observador (EO, envolvendo controles normais, pacientes com epilepsia e pacientes com doença de Alzheimer, através do coeficiente de correlação intra-classe (CCI. RESULTADOS: A confiabilidade IO para as estruturas analisadas variou de 0,93 a 0,99 (pRATIONALE: The development of reliable techniques for volumetric measurement of mesial temporal structures (amygdala, hypocampus and parahypocampal gyrus on magnetic resonance imaging (MRI can provide data for the study of neuropsychiatric disorders, mainly temporal lobe epilepsy, Alzheimer´s disease and schizophrenia. METHOD: We investigated these techniques performing intraobserver and interobserver reliability study concerning normal controls, epilepsy and Alzheimer's disease patients using the intra-class correlation coefficient. RESULTS: Intra-observer reliability of evaluated structures ranged from 0.93 to 0.99 (p<0.001. Inter-observer reliability ranged from 0.70 to 0.95 (p <= 0.001. CONCLUSION: The results suggest that the technique of MRI morphometry of mesial temporal regions can be considered a reliable tool which may help in the investigation of neuropsychiatric disorders, since used by adequately trained clinicians and researchers.

  20. The use and reliability of SymNose for quantitative measurement of the nose and lip in unilateral cleft lip and palate patients.

    Science.gov (United States)

    Mosmuller, David; Tan, Robin; Mulder, Frans; Bachour, Yara; de Vet, Henrica; Don Griot, Peter

    2016-10-01

    It is essential to have a reliable assessment method in order to compare the results of cleft lip and palate surgery. In this study the computer-based program SymNose, a method for quantitative assessment of the nose and lip, will be assessed on usability and reliability. The symmetry of the nose and lip was measured twice in 50 six-year-old complete and incomplete unilateral cleft lip and palate patients by four observers. For the frontal view the asymmetry level of the nose and upper lip were evaluated and for the basal view the asymmetry level of the nose and nostrils were evaluated. A mean inter-observer reliability when tracing each image once or twice was 0.70 and 0.75, respectively. Tracing the photographs with 2 observers and 4 observers gave a mean inter-observer score of 0.86 and 0.92, respectively. The mean intra-observer reliability varied between 0.80 and 0.84. SymNose is a practical and reliable tool for the retrospective assessment of large caseloads of 2D photographs of cleft patients for research purposes. Moderate to high single inter-observer reliability was found. For future research with SymNose reliable outcomes can be achieved by using the average outcomes of single tracings of two observers. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Reliability improvement methods for sapphire fiber temperature sensors

    Science.gov (United States)

    Schietinger, C.; Adams, B.

    1991-08-01

    Mechanical, optical, electrical, and software design improvements can be brought to bear in the enhancement of fiber-optic sapphire-fiber temperature measurement tool reliability in harsh environments. The optical fiber thermometry (OFT) equipment discussed is used in numerous process industries and generally involves a sapphire sensor, an optical transmission cable, and a microprocessor-based signal analyzer. OFT technology incorporating sensors for corrosive environments, hybrid sensors, and two-wavelength measurements, are discussed.

  2. Night-to-night arousal variability and interscorer reliability of arousal measurements.

    Science.gov (United States)

    Loredo, J S; Clausen, J L; Ancoli-Israel, S; Dimsdale, J E

    1999-11-01

    Measurement of arousals from sleep is clinically important, however, their definition is not well standardized, and little data exist on reliability. The purpose of this study is to determine factors that affect arousal scoring reliability and night-to-night arousal variability. The night-to-night arousal variability and interscorer reliability was assessed in 20 subjects with and without obstructive sleep apnea undergoing attended polysomnography during two consecutive nights. Five definitions of arousal were studied, assessing duration of electroencephalographic (EEG) frequency changes, increases in electromyographic (EMG) activity and leg movement, association with respiratory events, as well as the American Sleep Disorders Association (ASDA) definition of arousals. NA. NA. NA. Interscorer reliability varied with the definition of arousal and ranged from an Intraclass correlation (ICC) of 0.19 to 0.92. Arousals that included increases in EMG activity or leg movement had the greatest reliability, especially when associated with respiratory events (ICC 0.76 to 0.92). The ASDA arousal definition had high interscorer reliability (ICC 0.84). Reliability was lowest for arousals consisting of EEG changes lasting <3 seconds (ICC 0.19 to 0.37). The within subjects night-to-night arousal variability was low for all arousal definitions In a heterogeneous population, interscorer arousal reliability is enhanced by increases in EMG activity, leg movements, and respiratory events and decreased by short duration EEG arousals. The arousal index night-to-night variability was low for all definitions.

  3. Reliability of rehabilitative ultrasonographic imaging for muscle thickness measurement of the rhomboid major.

    Science.gov (United States)

    Jeong, Ju Ri; Ko, Young Jun; Ha, Hyun Geun; Lee, Wan Hee

    2016-03-01

    This study was to establish inter-rater and intrarater reliability of the rehabilitative ultrasonographic imaging (RUSI) technique for muscle thickness measurement of the rhomboid major at rest and with the shoulder abducted to 90°. Twenty-four young adults (eight men, 16 women; right-handed; mean age [±SD], 24·4 years [±2·6]) with no history of neck, shoulder, or arm pain were recruited. Rhomboid major muscle images were obtained in the resting position and with shoulder in 90° abduction using an ultrasonography system with a 7·5-MHz linear transducer. In these two positions, the examiners found the site at which the transducer could be placed. Two examiners obtained the images of all participants in three test sessions at random. Intraclass correlation coefficients (ICC) were used to estimate reliability. All ICCs (95% CI) were >0·75, ranging from 0·93 to 0·98, which indicates good reliability. The ICCs for inter-rater reliability ranged from 0·75 to 0·94. For the absolute value of the difference in the intra-examiner reliability between the right and left ratios, the ICCs ranged from 0·58 to 0·91. In this study, the intra- and interexaminer reliability of muscle thickness measurements of the rhomboid major were good. Therefore, we suggest that muscle thickness measurements of the rhomboid major obtained with the RUSI technique would be useful for clinical rehabilitative assessment. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  4. Low-Budget Instrumentation of a Conventional Leg Press to Measure Reliable Isometric-Strength Capacity.

    Science.gov (United States)

    Baur, Heiner; Groppa, Alessia Severina; Limacher, Regula; Radlinger, Lorenz

    2016-02-02

    Maximum strength and rate of force development (RFD) are 2 important strength characteristics for everyday tasks and athletic performance. Measurements of both parameters must be reliable. Expensive isokinetic devices with isometric modes are often used. The possibility of cost-effective measurements in a practical setting would facilitate quality control. The purpose of this study was to assess the reliability of measurements of maximum isometric strength (Fmax) and RFD on a conventional leg press. Sixteen subjects (23 ± 2 y, 1.68 ± 0.05 m, 59 ± 5 kg) were tested twice within 1 session. After warm-up, subjects performed 2 times 5 trials eliciting maximum voluntary isometric contractions on an instrumented leg press (1- and 2-legged randomized). Fmax (N) and RFD (N/s) were extracted from force-time curves. Reliability was determined for Fmax and RFD by calculating the intraclass correlation coefficient (ICC), the test-retest variability (TRV), and the bias and limits of agreement. Reliability measures revealed good to excellent ICCs of .80-.93. TRV showed mean differences between measurement sessions of 0.4-6.9%. The systematic error was low compared with the absolute mean values (Fmax 5-6%, RFD 1-4%). The implementation of a force transducer into a conventional leg press provides a viable procedure to assess Fmax and RFD. Both performance parameters can be assessed with good to excellent reliability allowing quality control of interventions.

  5. Best of the lot : engineered measurement-while-drilling tool improves efficiency of operations

    Energy Technology Data Exchange (ETDEWEB)

    Mahony, J.

    2010-10-15

    NuEra Oilfield Services Inc. combines various technologies, including advanced bearing assemblies and compact wireless decoders that interface with downhole directional tools, to engineer unique, purpose-built measurement-while-drilling (MWD) tool string packages. The 9-metre-long MWD tool string is lowered into the drill pipe from the surface. The directional module monitors the position of the drill bit, which the driller can monitor using an electronic drilling recorder at the surface. The directional drillstring uses a mud motor with adjustable bent housing to correct the direction of the well, as the system cannot steer while drilling. At bottomhole, mud circulation continues after the rotation of the drillstring has been stopped, driving the mud motor, which in turn drives the drill bit, permitting a new direction to be taken even though the drillstring is not turning. The operator points the bent housing in a new direction and slides the bit along before restarting the rotation of the drillstring. The NuEra drillstring uses a new bearing pack that makes the mud motor more robust and longer-lived, preventing costly down time for operators. The bearing pack is designed to distribute the load geometrically so that only one-third of the weight-on-bit is on the bearings at any point in time, which extends bearing life and reduces repair costs. The custom selection and mating of superior components made by different tool manufacturers has resulted in the MWD tool string that is reliable and able to pump more and carry more weight. 1 ref., 2 figs.

  6. The reliability of WorkWell Systems Functional Capacity Evaluation: a systematic review

    Science.gov (United States)

    2014-01-01

    Background Functional capacity evaluation (FCE) determines a person’s ability to perform work-related tasks and is a major component of the rehabilitation process. The WorkWell Systems (WWS) FCE (formerly known as Isernhagen Work Systems FCE) is currently the most commonly used FCE tool in German rehabilitation centres. Our systematic review investigated the inter-rater, intra-rater and test-retest reliability of the WWS FCE. Methods We performed a systematic literature search of studies on the reliability of the WWS FCE and extracted item-specific measures of inter-rater, intra-rater and test-retest reliability from the identified studies. Intraclass correlation coefficients ≥ 0.75, percentages of agreement ≥ 80%, and kappa coefficients ≥ 0.60 were categorised as acceptable, otherwise they were considered non-acceptable. The extracted values were summarised for the five performance categories of the WWS FCE, and the results were classified as either consistent or inconsistent. Results From 11 identified studies, 150 item-specific reliability measures were extracted. 89% of the extracted inter-rater reliability measures, all of the intra-rater reliability measures and 96% of the test-retest reliability measures of the weight handling and strength tests had an acceptable level of reliability, compared to only 67% of the test-retest reliability measures of the posture/mobility tests and 56% of the test-retest reliability measures of the locomotion tests. Both of the extracted test-retest reliability measures of the balance test were acceptable. Conclusions Weight handling and strength tests were found to have consistently acceptable reliability. Further research is needed to explore the reliability of the other tests as inconsistent findings or a lack of data prevented definitive conclusions. PMID:24674029

  7. Reliability and measurement error of sagittal spinal motion parameters in 220 patients with chronic low back pain using a three-dimensional measurement device.

    Science.gov (United States)

    Mieritz, Rune M; Bronfort, Gert; Jakobsen, Markus D; Aagaard, Per; Hartvigsen, Jan

    2014-09-01

    A basic premise for any instrument measuring spinal motion is that reliable outcomes can be obtained on a relevant sample under standardized conditions. The purpose of this study was to assess the overall reliability and measurement error of regional spinal sagittal plane motion in patients with chronic low back pain (LBP), and then to evaluate the influence of body mass index, examiner, gender, stability of pain, and pain distribution on reliability and measurement error. This study comprises a test-retest design separated by 7 to 14 days. The patient cohort consisted of 220 individuals with chronic LBP. Kinematics of the lumbar spine were sampled during standardized spinal extension-flexion testing using a 6-df instrumented spatial linkage system. Test-retest reliability and measurement error were evaluated using interclass correlation coefficients (ICC(1,1)) and Bland-Altman limits of agreement (LOAs). The overall test-retest reliability (ICC(1,1)) for various motion parameters ranged from 0.51 to 0.70, and relatively wide LOAs were observed for all parameters. Reliability measures in patient subgroups (ICC(1,1)) ranged between 0.34 and 0.77. In general, greater (ICC(1,1)) coefficients and smaller LOAs were found in subgroups with patients examined by the same examiner, patients with a stable pain level, patients with a body mass index less than below 30 kg/m(2), patients who were men, and patients in the Quebec Task Force classifications Group 1. This study shows that sagittal plane kinematic data from patients with chronic LBP may be sufficiently reliable in measurements of groups of patients. However, because of the large LOAs, this test procedure appears unusable at the individual patient level. Furthermore, reliability and measurement error varies substantially among subgroups of patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. The reliability of repeated TMS measures in older adults and in patients with subacute and chronic stroke

    Directory of Open Access Journals (Sweden)

    Heidi M. Schambra

    2015-09-01

    Full Text Available The reliability of transcranial magnetic stimulation (TMS measures in healthy older adults and stroke patients has been insufficiently characterized. We determined whether common TMS measures could reliably evaluate change in individuals and in groups using the smallest detectable change (SDC, or could tell subjects apart using the intraclass correlation coefficient (ICC. We used a single-rater test-retest design in older healthy, subacute stroke, and chronic stroke subjects. At twice daily sessions on two consecutive days, we recorded resting motor threshold, test stimulus intensity, recruitment curves, short-interval intracortical inhibition and facilitation, and long-interval intracortical inhibition. Using variances estimated from a random effects model, we calculated the SDC and ICC for each TMS measure. For all TMS measures in all groups, SDCs for single subjects were large; only with modest group sizes did the SDCs become low. Thus, while these TMS measures cannot be reliably used as a biomarker to detect individual change, they can reliably detect change exceeding measurement noise in moderate-sized groups. For several of the TMS measures, ICCs were universally high, suggesting that they can reliably discriminate between subjects. Though most TMS measures have sufficient reliability in particular contexts, work establishing their validity, responsiveness, and clinical relevance is still needed.

  9. CCTop: An Intuitive, Flexible and Reliable CRISPR/Cas9 Target Prediction Tool.

    Directory of Open Access Journals (Sweden)

    Manuel Stemmer

    Full Text Available Engineering of the CRISPR/Cas9 system has opened a plethora of new opportunities for site-directed mutagenesis and targeted genome modification. Fundamental to this is a stretch of twenty nucleotides at the 5' end of a guide RNA that provides specificity to the bound Cas9 endonuclease. Since a sequence of twenty nucleotides can occur multiple times in a given genome and some mismatches seem to be accepted by the CRISPR/Cas9 complex, an efficient and reliable in silico selection and evaluation of the targeting site is key prerequisite for the experimental success. Here we present the CRISPR/Cas9 target online predictor (CCTop, http://crispr.cos.uni-heidelberg.de to overcome limitations of already available tools. CCTop provides an intuitive user interface with reasonable default parameters that can easily be tuned by the user. From a given query sequence, CCTop identifies and ranks all candidate sgRNA target sites according to their off-target quality and displays full documentation. CCTop was experimentally validated for gene inactivation, non-homologous end-joining as well as homology directed repair. Thus, CCTop provides the bench biologist with a tool for the rapid and efficient identification of high quality target sites.

  10. Reliable intraocular pressure measurement using automated radio-wave telemetry.

    Science.gov (United States)

    Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B

    2014-01-01

    To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.

  11. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Science.gov (United States)

    Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B

    2014-01-01

    Purpose To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. Methods The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. Results On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. Conclusion IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results. PMID:24531415

  12. Reliability and validity of the ultrasound technique to measure the rectus femoris muscle diameter in older CAD-patients

    Directory of Open Access Journals (Sweden)

    Thomaes Tom

    2012-04-01

    Full Text Available Abstract Background The increasing age of coronary artery disease (CAD patients and the occurrence of sarcopenia in the elderly population accompanied by 'fear of moving' and hospitalization in these patients often results in a substantial loss of skeletal muscle mass and muscle strength. Cardiac rehabilitation can improve exercise tolerance and muscle strength in CAD patients but less data describe eventual morphological muscular changes possibly by more difficult access to imaging techniques. Therefore the aim of this study is to assess and quantify the reliability and validity of an easy applicable method, the ultrasound (US technique, to measure the diameter of rectus femoris muscle in comparison to the muscle dimensions measured with CT scans. Methods 45 older CAD patients without cardiac event during the last 9 months were included in this study. 25 patients were tested twice with ultrasound with a two day interval to assess test-retest reliability and 20 patients were tested twice (once with US and once with CT on the same day to assess the validity of the US technique compared to CT as the gold standard. Isometric and isokinetic muscle testing was performed to test potential zero-order correlations between muscle diameter, muscle volume and muscle force. Results An intraclass correlation coefficient (ICC of 0.97 ((95%CL: 0.92 - 0.99 was found for the test-retest reliability of US and the ICC computed between US and CT was 0.92 (95%CL: 0.81 - 0.97. The absolute difference between both techniques was 0.01 ± 0.12 cm (p = 0.66 resulting in a typical percentage error of 4.4%. Significant zero-order correlations were found between local muscle volume and muscle diameter assessed with CT (r = 0.67, p = 0.001 and assessed with US (r = 0.49, p Conclusions Ultrasound imaging can be used as a valid and reliable measurement tool to assess the rectus femoris muscle diameter in older CAD patients.

  13. Reliability and Validity of the Behavioral Addiction Measure for Video Gaming.

    Science.gov (United States)

    Sanders, James L; Williams, Robert J

    2016-01-01

    Most tests of video game addiction have weak construct validity and limited ability to correctly identify people in denial. The purpose of the present research was to investigate the reliability and validity of a new test of video game addiction (Behavioral Addiction Measure-Video Gaming [BAM-VG]) that was developed in part to address these deficiencies. Regular adult video gamers (n = 506) were recruited from a Canadian online panel and completed a survey containing three measures of excessive video gaming (BAM-VG; DSM-5 criteria for Internet Gaming Disorder [IGD]; and the IGD-20), as well as questions concerning extensiveness of video game involvement and self-report of problems associated with video gaming. One month later, they were reassessed for the purposes of establishing test-retest reliability. The BAM-VG demonstrated good internal consistency as well as 1 month test-retest reliability. Criterion-related validity was demonstrated by significant correlations with the following: time spent playing, self-identification of video game problems, and scores on other instruments designed to assess video game addiction (DSM-5 IGD, IGD-20). Consistent with the theory, principal component analysis identified two components underlying the BAM-VG that roughly correspond with impaired control and significant negative consequences deriving from this impaired control. Together with its excellent construct validity and other technical features, the BAM-VG represents a reliable and valid test of video game addiction.

  14. The reliability and validity of hand-held refractometry water content measures of hydrogel lenses.

    Science.gov (United States)

    Nichols, Jason J; Mitchell, G Lynn; Good, Gregory W

    2003-06-01

    To investigate within- and between-examiner reliability and validity of hand-held refractometry water content measures of hydrogel lenses. Nineteen lenses of various nominal water contents were examined by two examiners on two occasions separated by 1 hour. An Atago N2 hand-held refractometer was used for all water content measures. Lenses were presented in a random order to each examiner by a third party, and examiners were masked to any potential lens identifiers. Intraclass correlation coefficients (ICC), 95% limits of agreement, and Wilcoxon signed rank test were used to characterize the within- and between-examiner reliability and validity of lens water content measures. Within-examiner reliability was excellent (ICC, 0.97; 95% limits of agreement, -3.6% to +5.7%), and the inter-visit mean difference of 1.1 +/- 2.4% was not biased (p = 0.08). Between-examiner reliability was also excellent (ICC, 0.98; 95% limits of agreement, -4.1% to +3.9%). The mean difference between examiners was -0.1 +/- 2.1% (p = 0.83). The mean difference between the nominally reported water content and our water content measures was -2.1 +/- 1.7% (p refractometry and is material dependent. Therefore, investigators may need to account for bias when measuring hydrogel lens water content via hand-held refractometry.

  15. The Impact of a Mechanical Press on the Accuracy of Products and the Reliability of Tools in Cold Forging

    DEFF Research Database (Denmark)

    Krusic, V.; Arentoft, Mogens; Rodic, T.

    2005-01-01

    Cold extrusion is an economic production process for the production of elements of complex forms and accurate dimensions. The first part of the article is about the impact that mechanical press has on the accuracy of products and reliability of tools. There is a description of the mechanical pres...

  16. Autism detection in early childhood (ADEC): reliability and validity data for a Level 2 screening tool for autistic disorder.

    Science.gov (United States)

    Nah, Yong-Hwee; Young, Robyn L; Brewer, Neil; Berlingeri, Genna

    2014-03-01

    The Autism Detection in Early Childhood (ADEC; Young, 2007) was developed as a Level 2 clinician-administered autistic disorder (AD) screening tool that was time-efficient, suitable for children under 3 years, easy to administer, and suitable for persons with minimal training and experience with AD. A best estimate clinical Diagnostic and Statistical Manual of Mental Disorders (4th ed., text rev.; DSM-IV-TR; American Psychiatric Association, 2000) diagnosis of AD was made for 70 children using all available information and assessment results, except for the ADEC data. A screening study compared these children on the ADEC with 57 children with other developmental disorders and 64 typically developing children. Results indicated high internal consistency (α = .91). Interrater reliability and test-retest reliability of the ADEC were also adequate. ADEC scores reliably discriminated different diagnostic groups after controlling for nonverbal IQ and Vineland Adaptive Behavior Composite scores. Construct validity (using exploratory factor analysis) and concurrent validity using performance on the Autism Diagnostic Observation Schedule (Lord et al., 2000), the Autism Diagnostic Interview-Revised (Le Couteur, Lord, & Rutter, 2003), and DSM-IV-TR criteria were also demonstrated. Signal detection analysis identified the optimal ADEC cutoff score, with the ADEC identifying all children who had an AD (N = 70, sensitivity = 1.0) but overincluding children with other disabilities (N = 13, specificity ranging from .74 to .90). Together, the reliability and validity data indicate that the ADEC has potential to be established as a suitable and efficient screening tool for infants with AD. 2014 APA

  17. Smartphone photography utilized to measure wrist range of motion.

    Science.gov (United States)

    Wagner, Eric R; Conti Mica, Megan; Shin, Alexander Y

    2018-02-01

    The purpose was to determine if smartphone photography is a reliable tool in measuring wrist movement. Smartphones were used to take digital photos of both wrists in 32 normal participants (64 wrists) at extremes of wrist motion. The smartphone measurements were compared with clinical goniometry measurements. There was a very high correlation between the clinical goniometry and smartphone measurements, as the concordance coefficients were high for radial deviation, ulnar deviation, wrist extension and wrist flexion. The Pearson coefficients also demonstrated the high precision of the smartphone measurements. The Bland-Altman plots demonstrated 29-31 of 32 smartphone measurements were within the 95% confidence interval of the clinical measurements for all positions of the wrists. There was high reliability between the photography taken by the volunteer and researcher, as well as high inter-observer reliability. Smartphone digital photography is a reliable and accurate tool for measuring wrist range of motion. II.

  18. Visual-Haptic Integration: Cue Weights are Varied Appropriately, to Account for Changes in Haptic Reliability Introduced by Using a Tool

    OpenAIRE

    Chie Takahashi; Simon J Watt

    2011-01-01

    Tools such as pliers systematically change the relationship between an object's size and the hand opening required to grasp it. Previous work suggests the brain takes this into account, integrating visual and haptic size information that refers to the same object, independent of the similarity of the ‘raw’ visual and haptic signals (Takahashi et al., VSS 2009). Variations in tool geometry also affect the reliability (precision) of haptic size estimates, however, because they alter the change ...

  19. Reliability and Accuracy of Brain Volume Measurement on MR Imaging

    DEFF Research Database (Denmark)

    Yamagchii, Kechiro; Lassen, Anders; Ring, Poul

    1998-01-01

    Yamaguchi, K., Lassen, A. And Ring, P. Reliability and Accuracy of Brain Volume Measurement on MR Imaging. Abstract at ESMRMB98 European Society for Magnetic Resonance in Medicine and Biology, Geneva, Sept 17-20, 1998 Danish Research Center for Magnetic Resonance, Hvidovre University Hospital...

  20. Reliability of the craniocervical posture assessment: visual and angular measurements using photographs and radiographs.

    Science.gov (United States)

    Gadotti, Inae C; Armijo-Olivo, Susan; Silveira, Anelise; Magee, David

    2013-01-01

    The purposes of this study were to determine the intrarater and interrater reliability of the craniocervical posture in a sagittal view using quantitative measurements on photographs and radiographs and to determine the agreement of the visual assessment of posture between raters. One photograph and 1 radiograph of the sagittal craniocervical posture were simultaneously taken from 39 healthy female subjects. Three angles were measured on the photographs and 10 angles on the radiographs of 22 subjects using Alcimage software (Alcimage; Uberlândia, MG, Brazil). Two repeated measurements were performed by 2 raters. The measurements were compared within and between raters to test the intrarater and interrater reliability, respectively. Intraclass correlation coefficient and SEM were used. κ Agreement was calculated for the visual assessment of 39 subjects using photographs and radiographs between 2 raters. Good to excellent intrarater and interrater intraclass correlation coefficient values were found on both photographs and radiographs. Interrater SEM was large and clinically significant for cervical lordosis photogrammetry and for 1 angle measuring cervical lordosis on radiographs. Interrater κ agreement for the visual assessment using photographs was poor (κ = 0.37). The raters were reliable to measure angles in photographs and radiographs to quantify craniocervical posture with exception of 2 angles measuring lordosis of the cervical spine when compared between raters. The visual assessment of posture between raters was not reliable. © 2013. Published by National University of Health Sciences All rights reserved.

  1. Reliability Measure Model for Assistive Care Loop Framework Using Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Venki Balasubramanian

    2010-01-01

    Full Text Available Body area wireless sensor networks (BAWSNs are time-critical systems that rely on the collective data of a group of sensor nodes. Reliable data received at the sink is based on the collective data provided by all the source sensor nodes and not on individual data. Unlike conventional reliability, the definition of retransmission is inapplicable in a BAWSN and would only lead to an elapsed data arrival that is not acceptable for time-critical application. Time-driven applications require high data reliability to maintain detection and responses. Hence, the transmission reliability for the BAWSN should be based on the critical time. In this paper, we develop a theoretical model to measure a BAWSN's transmission reliability, based on the critical time. The proposed model is evaluated through simulation and then compared with the experimental results conducted in our existing Active Care Loop Framework (ACLF. We further show the effect of the sink buffer in transmission reliability after a detailed study of various other co-existing parameters.

  2. Creation of complexity assessment tool for patients receiving home care

    Directory of Open Access Journals (Sweden)

    Maria Leopoldina de Castro Villas Bôas

    2016-06-01

    Full Text Available Abstract OBJECTIVE To create and validate a complexity assessment tool for patients receiving home care from a public health service. METHOD A diagnostic accuracy study, with estimates for the tool's validity and reliability. Measurements of sensitivity and specificity were considered when producing validity estimates. The resulting tool was used for testing. Assessment by a specialized team of home care professionals was used as the gold standard. In the tool's reliability study, the authors used the Kappa statistic. The tool's sensitivity and specificity were analyzed using various cut-off points. RESULTS On the best cut-off point-21-with the gold standard, a sensitivity of 75.5% was obtained, with the limits of confidence interval (95% at 68.3% and 82.8% and specificity of 53.2%, with the limits of confidence interval (95% at 43.8% and 62.7%. CONCLUSION The tool presented evidence of validity and reliability, possibly helping in service organization at patient admission, care type change, or support during the creation of care plans.

  3. Towards higher reliability of CMS computing facilities

    International Nuclear Information System (INIS)

    Bagliesi, G; Bloom, K; Brew, C; Flix, J; Kreuzer, P; Sciabà, A

    2012-01-01

    The CMS experiment has adopted a computing system where resources are distributed worldwide in more than 50 sites. The operation of the system requires a stable and reliable behaviour of the underlying infrastructure. CMS has established procedures to extensively test all relevant aspects of a site and their capability to sustain the various CMS computing workflows at the required scale. The Site Readiness monitoring infrastructure has been instrumental in understanding how the system as a whole was improving towards LHC operations, measuring the reliability of sites when running CMS activities, and providing sites with the information they need to troubleshoot any problem. This contribution reviews the complete automation of the Site Readiness program, with the description of monitoring tools and their inclusion into the Site Status Board (SSB), the performance checks, the use of tools like HammerCloud, and the impact in improving the overall reliability of the Grid from the point of view of the CMS computing system. These results are used by CMS to select good sites to conduct workflows, in order to maximize workflows efficiencies. The performance against these tests seen at the sites during the first years of LHC running is as well reviewed.

  4. Reliability of isometric lower-extremity muscle strength measurements in children with cerebral palsy: implications for measurement design

    NARCIS (Netherlands)

    Willemse, Lydia; Brehm, Merel A.; Scholtes, Vanessa A.; Jansen, Laura; Woudenberg-Vos, Hester; Dallmeijer, Annet J.

    2013-01-01

    Children with cerebral palsy (CP) typically show muscle weakness of the lower extremities, which can be measured with the use of handheld dynamometry (HHD). The purposes of this study were: (1) to determine test-retest reliability and measurement error of isometric lower-extremity strength

  5. A heuristic-based approach for reliability importance assessment of energy producers

    International Nuclear Information System (INIS)

    Akhavein, A.; Fotuhi Firuzabad, M.

    2011-01-01

    Reliability of energy supply is one of the most important issues of service quality. On one hand, customers usually have different expectations for service reliability and price. On the other hand, providing different level of reliability at load points is a challenge for system operators. In order to take reasonable decisions and obviate reliability implementation difficulties, market players need to know impacts of their assets on system and load-point reliabilities. One tool to specify reliability impacts of assets is the criticality or reliability importance measure by which system components can be ranked based on their effect on reliability. Conventional methods for determination of reliability importance are essentially on the basis of risk sensitivity analysis and hence, impose prohibitive calculation burden in large power systems. An approach is proposed in this paper to determine reliability importance of energy producers from perspective of consumers or distribution companies in a composite generation and transmission system. In the presented method, while avoiding immense computational burden, the energy producers are ranked based on their rating, unavailability and impact on power flows in the lines connecting to the considered load points. Study results on the IEEE reliability test system show successful application of the proposed method. - Research highlights: → Required reliability level at load points is a concern in modern power systems. → It is important to assess reliability importance of energy producers or generators. → Generators can be ranked based on their impacts on power flow to a selected area. → Ranking of generators is an efficient tool to assess their reliability importance.

  6. Strategy for continuous improvement in IC manufacturability, yield, and reliability

    Science.gov (United States)

    Dreier, Dean J.; Berry, Mark; Schani, Phil; Phillips, Michael; Steinberg, Joe; DePinto, Gary

    1993-01-01

    Continual improvements in yield, reliability and manufacturability measure a fab and ultimately result in Total Customer Satisfaction. A new organizational and technical methodology for continuous defect reduction has been established in a formal feedback loop, which relies on yield and reliability, failed bit map analysis, analytical tools, inline monitoring, cross functional teams and a defect engineering group. The strategy requires the fastest detection, identification and implementation of possible corrective actions. Feedback cycle time is minimized at all points to improve yield and reliability and reduce costs, essential for competitiveness in the memory business. Payoff was a 9.4X reduction in defectivity and a 6.2X improvement in reliability of 256 K fast SRAMs over 20 months.

  7. Development and preliminary validation of the EASE: a tool to measure perceived singing voice function.

    Science.gov (United States)

    Phyland, Debra J; Pallant, Julie F; Benninger, Michael S; Thibeault, Susan L; Greenwood, Ken M; Smith, Julian A; Vallance, Neil

    2013-07-01

    Most voice self-rating tools are disease-specific measures and are not suitable for use with healthy voice users. There is a need for a tool that is sensitive to the subtleties of a singer's voice and to perceived physical changes in the singing voice mechanism as a function of load. The aim of this study was to devise and validate a scale to assess singer's perceptions of the current status of their singing voice. Ninety-five vocal health descriptors were collected from focus group interviews of singers. These were reviewed by 25 currently performing music theater (MT) singers. Based on a consensus technique, the number of descriptors was decreased to 42 items. These were administered to a sample of 284 professional MT singers using an online survey to evaluate their perception of current singing voice status. Principal component analysis identified two subsets of items. Rasch analysis was used to evaluate and refine these sets of items to form two 10-item subscales. Both subscales demonstrated good overall fit to the Rasch model, no differential item functioning by sex or age, and good internal consistency reliability. The two subscales were strongly correlated and subsequent Rasch analysis supported their combination to form a single 20-item scale with good psychometric properties. The Evaluation of the Ability to Sing Easily (EASE) is a concise clinical tool to assess singer's perceptions of the current status of their singing voice with good measurement properties. EASE may prove a useful tool to measure changes in the singing voice as indicators of the effect of vocal load. Furthermore, it may offer a valuable means for the prediction or screening of singers "at risk" of developing voice disorders. Copyright © 2013 The Voice Foundation. All rights reserved.

  8. Measurement properties of screening and diagnostic tools for autism spectrum adults of mean normal intelligence: A systematic review.

    Science.gov (United States)

    Baghdadli, A; Russet, F; Mottron, L

    2017-07-01

    The autism spectrum (AS) is a multifaceted neurodevelopmental variant associated with lifelong challenges. Despite the relevant importance of identifying AS in adults for epidemiological, public health, and quality of life issues, the measurement properties of the tools currently used to screen and diagnose adults without intellectual disabilities (ID) have not been assessed. This systematic review addresses the accuracy, reliability, and validity of the reported AS screening and diagnostic tools used in adults without ID. Electronic databases and bibliographies were searched, and identified papers evaluated against inclusion criteria. The PRISMA statement was used for reporting the review. We evaluated the quality of the papers using the COSMIN Checklist for psychometric data, and QUADAS-2 for diagnostic data. For the COSMIN assessment, evidence was considered to be strong when several methodologically good articles, or one excellent article, reported consistent evidence for or against a measurement property. For the QUADAS ratings, evidence was considered to be "satisfactory" if at least one study was rated with a low risk of bias and low concern about applicability. We included 38 articles comprising 32 studies, five reviews, and one book chapter and assessed nine tools (three diagnostic and six screening, including eight of their short versions). Among screening tools, only AQ-50, AQ-S, and RAADS-R and RAADS-14 were found to provide satisfactory or intermediate values for their psychometric properties, supported by strong or moderate evidence. Nevertheless, risks of bias and concerns on the applicability of these tools limit the evidence on their diagnostic properties. We found that none of the gold standard diagnostic tools used for children had satisfactory measurement properties. There is limited evidence for the measurement properties of the screening and diagnostic tools used for AS adults with a mean normal range of measured intelligence. This may lessen

  9. Test-retest reliability of Antonovsky's 13-item sense of coherence scale in patients with hand-related disorders

    DEFF Research Database (Denmark)

    Hansen, Alice Ørts; Kristensen, Hanne Kaae; Cederlund, Ragnhild

    2017-01-01

    to be a powerful tool to measure the ICF component personal factors, which could have an impact on patients' rehabilitation outcomes. Implications for rehabilitation Antonovsky's SOC-13 scale showed test-retest reliability for patients with hand-related disorders. The SOC-13 scale could be a suitable tool to help...... measure personal factors....

  10. Measuring the Performance of Attention Networks with the Dalhousie Computerized Attention Battery (DalCAB): Methodology and Reliability in Healthy Adults.

    Science.gov (United States)

    Jones, Stephanie A H; Butler, Beverly C; Kintzel, Franziska; Johnson, Anne; Klein, Raymond M; Eskes, Gail A

    2016-01-01

    Attention is an important, multifaceted cognitive domain that has been linked to three distinct, yet interacting, networks: alerting, orienting, and executive control. The measurement of attention and deficits of attention within these networks is critical to the assessment of many neurological and psychiatric conditions in both research and clinical settings. The Dalhousie Computerized Attention Battery (DalCAB) was created to assess attentional functions related to the three attention networks using a range of tasks including: simple reaction time, go/no-go, choice reaction time, dual task, flanker, item and location working memory, and visual search. The current study provides preliminary normative data, test-retest reliability (intraclass correlations) and practice effects in DalCAB performance 24-h after baseline for healthy young adults (n = 96, 18-31 years). Performance on the DalCAB tasks demonstrated Good to Very Good test-retest reliability for mean reaction time, while accuracy and difference measures (e.g., switch costs, interference effects, and working memory load effects) were most reliable for tasks that require more extensive cognitive processing (e.g., choice reaction time, flanker, dual task, and conjunction search). Practice effects were common and pronounced at the 24-h interval. In addition, performance related to specific within-task parameters of the DalCAB sub-tests provides preliminary support for future formal assessment of the convergent validity of our interpretation of the DalCAB as a potential clinical and research assessment tool for measuring aspects of attention related to the alerting, orienting, and executive control networks.

  11. Measuring the performance of attention networks with the Dalhousie Computerized Attention Battery (DalCAB: Methodology and reliability in healthy adults

    Directory of Open Access Journals (Sweden)

    Stephanie Anne Holland Jones

    2016-06-01

    Full Text Available Attention is an important, multifaceted cognitive domain that has been linked to three distinct, yet interacting, networks: alerting, orienting, and executive control. The measurement of attention and deficits of attention within these networks is critical to the assessment of many neurological and psychiatric conditions in both research and clinical settings. The Dalhousie Computerized Attention Battery (DalCAB was created to assess attentional functions related to the three attention networks using a range of tasks including: simple reaction time, go/no-go, choice reaction time, dual task, flanker, item and location working memory and visual search. The current study provides preliminary normative data, test-retest reliability (intraclass correlations and practice effects in DalCAB performance 24-hours after baseline for healthy young adults (n = 96, 18-31 years. Performance on the DalCAB tasks demonstrated Good to Excellent test-retest reliability for mean reaction time, while accuracy and difference measures (e.g., switch costs, interference effects and working memory load effects were most reliable for tasks that require more extensive cognitive processing (e.g., choice reaction time, flanker, dual task, and conjunction search. Practice effects were common and pronounced at the 24-hour interval. In addition, performance related to specific within-task parameters of the DalCAB sub-tests provides preliminary support for future formal assessment of the convergent validity of our interpretation of the DalCAB as a potential clinical and research assessment tool for measuring aspects of attention related to the alerting, orienting and executive control networks.Keywords: computerized assessment; attention; orienting; alerting; executive function

  12. The reliability of workplace-based assessment in postgraduate medical education and training: a national evaluation in general practice in the United Kingdom.

    Science.gov (United States)

    Murphy, Douglas J; Bruce, David A; Mercer, Stewart W; Eva, Kevin W

    2009-05-01

    To investigate the reliability and feasibility of six potential workplace-based assessment methods in general practice training: criterion audit, multi-source feedback from clinical and non-clinical colleagues, patient feedback (the CARE Measure), referral letters, significant event analysis, and video analysis of consultations. Performance of GP registrars (trainees) was evaluated with each tool to assess the reliabilities of the tools and feasibility, given raters and number of assessments needed. Participant experience of process determined by questionnaire. 171 GP registrars and their trainers, drawn from nine deaneries (representing all four countries in the UK), participated. The ability of each tool to differentiate between doctors (reliability) was assessed using generalisability theory. Decision studies were then conducted to determine the number of observations required to achieve an acceptably high reliability for "high-stakes assessment" using each instrument. Finally, descriptive statistics were used to summarise participants' ratings of their experience using these tools. Multi-source feedback from colleagues and patient feedback on consultations emerged as the two methods most likely to offer a reliable and feasible opinion of workplace performance. Reliability co-efficients of 0.8 were attainable with 41 CARE Measure patient questionnaires and six clinical and/or five non-clinical colleagues per doctor when assessed on two occasions. For the other four methods tested, 10 or more assessors were required per doctor in order to achieve a reliable assessment, making the feasibility of their use in high-stakes assessment extremely low. Participant feedback did not raise any major concerns regarding the acceptability, feasibility, or educational impact of the tools. The combination of patient and colleague views of doctors' performance, coupled with reliable competence measures, may offer a suitable evidence-base on which to monitor progress and

  13. Semi-structured interview is a reliable and feasible tool for selection of doctors for general practice specialist training

    DEFF Research Database (Denmark)

    Isaksen, Jesper; Hertel, Niels Thomas; Kjær, Niels Kristian

    2013-01-01

    In order to optimise the selection process for admission to specialist training in family medicine, we developed a new design for structured applications and selection interviews. The design contains semi-structured interviews, which combine individualised elements from the applications...... with standardised behaviour-based questions. This paper describes the design of the tool, and offers reflections concerning its acceptability, reliability and feasibility....

  14. Is the Scale for Measuring Motivational Interviewing Skills a valid and reliable instrument for measuring the primary care professionals motivational skills?: EVEM study protocol.

    Science.gov (United States)

    Pérula, Luis Á; Campiñez, Manuel; Bosch, Josep M; Barragán Brun, Nieves; Arboniés, Juan C; Bóveda Fontán, Julia; Martín Alvarez, Remedios; Prados, Jose A; Martín-Rioboó, Enrique; Massons, Josep; Criado, Margarita; Fernández, José Á; Parras, Juan M; Ruiz-Moral, Roger; Novo, Jesús M

    2012-11-22

    Lifestyle is one of the main determinants of people's health. It is essential to find the most effective prevention strategies to be used to encourage behavioral changes in their patients. Many theories are available that explain change or adherence to specific health behaviors in subjects. In this sense the named Motivational Interviewing has increasingly gained relevance. Few well-validated instruments are available for measuring doctors' communication skills, and more specifically the Motivational Interviewing. The hypothesis of this study is that the Scale for Measuring Motivational Interviewing Skills (EVEM questionnaire) is a valid and reliable instrument for measuring the primary care professionals skills to get behavior change in patients. To test the hypothesis we have designed a prospective, observational, multi-center study to validate a measuring instrument. - Thirty-two primary care centers in Spain. -Sampling and Size: a) face and consensual validity: A group composed of 15 experts in Motivational Interviewing. b) Assessment of the psychometric properties of the scale; 50 physician- patient encounters will be videoed; a total of 162 interviews will be conducted with six standardized patients, and another 200 interviews will be conducted with 50 real patients (n=362). Four physicians will be specially trained to assess 30 interviews randomly selected to test the scale reproducibility. -Measurements for to test the hypothesis: a) Face validity: development of a draft questionnaire based on a theoretical model, by using Delphi-type methodology with experts. b) Scale psychometric properties: intraobservers will evaluate video recorded interviews: content-scalability validity (Exploratory Factor Analysis), internal consistency (Cronbach alpha), intra-/inter-observer reliability (Kappa index, intraclass correlation coefficient, Bland & Altman methodology), generalizability, construct validity and sensitivity to change (Pearson product-moment correlation

  15. Is the Scale for Measuring Motivational Interviewing Skills a valid and reliable instrument for measuring the primary care professionals motivational skills?: EVEM study protocol

    Directory of Open Access Journals (Sweden)

    Pérula Luis Á

    2012-11-01

    Full Text Available Abstract Background Lifestyle is one of the main determinants of people’s health. It is essential to find the most effective prevention strategies to be used to encourage behavioral changes in their patients. Many theories are available that explain change or adherence to specific health behaviors in subjects. In this sense the named Motivational Interviewing has increasingly gained relevance. Few well-validated instruments are available for measuring doctors’ communication skills, and more specifically the Motivational Interviewing. Methods/Design The hypothesis of this study is that the Scale for Measuring Motivational Interviewing Skills (EVEM questionnaire is a valid and reliable instrument for measuring the primary care professionals skills to get behavior change in patients. To test the hypothesis we have designed a prospective, observational, multi-center study to validate a measuring instrument. –Scope: Thirty-two primary care centers in Spain. -Sampling and Size: a face and consensual validity: A group composed of 15 experts in Motivational Interviewing. b Assessment of the psychometric properties of the scale; 50 physician- patient encounters will be videoed; a total of 162 interviews will be conducted with six standardized patients, and another 200 interviews will be conducted with 50 real patients (n=362. Four physicians will be specially trained to assess 30 interviews randomly selected to test the scale reproducibility. -Measurements for to test the hypothesis: a Face validity: development of a draft questionnaire based on a theoretical model, by using Delphi-type methodology with experts. b Scale psychometric properties: intraobservers will evaluate video recorded interviews: content-scalability validity (Exploratory Factor Analysis, internal consistency (Cronbach alpha, intra-/inter-observer reliability (Kappa index, intraclass correlation coefficient, Bland & Altman methodology, generalizability, construct validity and

  16. The FLIR ONE thermal imager for the assessment of burn wounds: Reliability and validity study.

    Science.gov (United States)

    Jaspers, M E H; Carrière, M E; Meij-de Vries, A; Klaessens, J H G M; van Zuijlen, P P M

    2017-11-01

    Objective measurement tools may be of great value to provide early and reliable burn wound assessment. Thermal imaging is an easy, accessible and objective technique, which measures skin temperature as an indicator of tissue perfusion. These thermal images might be helpful in the assessment of burn wounds. However, before implementation of a novel measurement tool into clinical practice is considered, it is appropriate to test its clinimetric properties (i.e. reliability and validity). The objective of this study was to assess the reliability and validity of the recently introduced FLIR ONE thermal imager. Two observers obtained thermal images of burn wounds in adult patients at day 1-3, 4-7 and 8-10 after burn. Subsequently, temperature differences between the burn wound and healthy skin (ΔT) were calculated on an iPad mini containing the FLIR Tools app. To assess reliability, ΔT values of both observers were compared by calculating the intraclass correlation coefficient (ICC) and measurement error parameters. To assess validity, the ΔT values of the first observer were compared to the registered healing time of the burn wounds, which was specified into three categories: (I) ≤14 days, (II) 15-21 days and (III) >21 days. The ability of the FLIR ONE to discriminate between healing ≤21 days and >21 days was evaluated by means of a receiver operating characteristic curve and an optimal ΔT cut-off value. Reliability: ICCs were 0.99 for each time point, indicating excellent reliability up to 10 days after burn. The standard error of measurement varied between 0.17-0.22°C. the area under the curve was calculated at 0.69 (95% CI 0.54-0.84). A cut-off value of -1.15°C shows a moderate discrimination between burn wound healing ≤21 days and >21 days (46% sensitivity; 82% specificity). Our results show that the FLIR ONE thermal imager is highly reliable, but the moderate validity calls for additional research. However, the FLIR ONE is pre-eminently feasible

  17. The reliability of vertical jump tests between the Vertec and My Jump phone application.

    Science.gov (United States)

    Yingling, Vanessa R; Castro, Dimitri A; Duong, Justin T; Malpartida, Fiorella J; Usher, Justin R; O, Jenny

    2018-01-01

    The vertical jump is used to estimate sports performance capabilities and physical fitness in children, elderly, non-athletic and injured individuals. Different jump techniques and measurement tools are available to assess vertical jump height and peak power; however, their use is limited by access to laboratory settings, excessive cost and/or time constraints thus making these tools oftentimes unsuitable for field assessment. A popular field test uses the Vertec and the Sargent vertical jump with countermovement; however, new low cost, easy to use tools are becoming available, including the My Jump iOS mobile application (app). The purpose of this study was to assess the reliability of the My Jump relative to values obtained by the Vertec for the Sargent stand and reach vertical jump (VJ) test. One hundred and thirty-five healthy participants aged 18-39 years (94 males, 41 females) completed three maximal Sargent VJ with countermovement that were simultaneously measured using the Vertec and the My Jump . Jump heights were quantified for each jump and peak power was calculated using the Sayers equation. Four separate ICC estimates and their 95% confidence intervals were used to assess reliability. Two analyses (with jump height and calculated peak power as the dependent variables, respectively) were based on a single rater, consistency, two-way mixed-effects model, while two others (with jump height and calculated peak power as the dependent variables, respectively) were based on a single rater, absolute agreement, two-way mixed-effects model. Moderate to excellent reliability relative to the degree of consistency between the Vertec and My Jump values was found for jump height (ICC = 0.813; 95% CI [0.747-0.863]) and calculated peak power (ICC = 0.926; 95% CI [0.897-0.947]). However, poor to good reliability relative to absolute agreement for VJ height (ICC = 0.665; 95% CI [0.050-0.859]) and poor to excellent reliability relative to absolute agreement for peak power

  18. Supersonic shear imaging provides a reliable measurement of resting muscle shear elastic modulus

    International Nuclear Information System (INIS)

    Lacourpaille, Lilian; Hug, François; Bouillard, Killian; Nordez, Antoine; Hogrel, Jean-Yves

    2012-01-01

    The aim of the present study was to assess the reliability of shear elastic modulus measurements performed using supersonic shear imaging (SSI) in nine resting muscles (i.e. gastrocnemius medialis, tibialis anterior, vastus lateralis, rectus femoris, triceps brachii, biceps brachii, brachioradialis, adductor pollicis obliquus and abductor digiti minimi) of different architectures and typologies. Thirty healthy subjects were randomly assigned to the intra-session reliability (n = 20), inter-day reliability (n = 21) and the inter-observer reliability (n = 16) experiments. Muscle shear elastic modulus ranged from 2.99 (gastrocnemius medialis) to 4.50 kPa (adductor digiti minimi and tibialis anterior). On the whole, very good reliability was observed, with a coefficient of variation (CV) ranging from 4.6% to 8%, except for the inter-operator reliability of adductor pollicis obliquus (CV = 11.5%). The intraclass correlation coefficients were good (0.871 ± 0.045 for the intra-session reliability, 0.815 ± 0.065 for the inter-day reliability and 0.709 ± 0.141 for the inter-observer reliability). Both the reliability and the ease of use of SSI make it a potentially interesting technique that would be of benefit to fundamental, applied and clinical research projects that need an accurate assessment of muscle mechanical properties. (note)

  19. Reliability and Validity Assessment of a Linear Position Transducer

    Science.gov (United States)

    Garnacho-Castaño, Manuel V.; López-Lastra, Silvia; Maté-Muñoz, José L.

    2015-01-01

    The objectives of the study were to determine the validity and reliability of peak velocity (PV), average velocity (AV), peak power (PP) and average power (AP) measurements were made using a linear position transducer. Validity was assessed by comparing measurements simultaneously obtained using the Tendo Weightlifting Analyzer Systemi and T-Force Dynamic Measurement Systemr (Ergotech, Murcia, Spain) during two resistance exercises, bench press (BP) and full back squat (BS), performed by 71 trained male subjects. For the reliability study, a further 32 men completed both lifts using the Tendo Weightlifting Analyzer Systemz in two identical testing sessions one week apart (session 1 vs. session 2). Intraclass correlation coefficients (ICCs) indicating the validity of the Tendo Weightlifting Analyzer Systemi were high, with values ranging from 0.853 to 0.989. Systematic biases and random errors were low to moderate for almost all variables, being higher in the case of PP (bias ±157.56 W; error ±131.84 W). Proportional biases were identified for almost all variables. Test-retest reliability was strong with ICCs ranging from 0.922 to 0.988. Reliability results also showed minimal systematic biases and random errors, which were only significant for PP (bias -19.19 W; error ±67.57 W). Only PV recorded in the BS showed no significant proportional bias. The Tendo Weightlifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and estimating power in resistance exercises. The low biases and random errors observed here (mainly AV, AP) make this device a useful tool for monitoring resistance training. Key points This study determined the validity and reliability of peak velocity, average velocity, peak power and average power measurements made using a linear position transducer The Tendo Weight-lifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and power. PMID:25729300

  20. Smartphones as a Light Measurement Tool: Case of Study

    Directory of Open Access Journals (Sweden)

    Jose-Maria Gutierrez-Martinez

    2017-06-01

    Full Text Available In recent years, smartphones have become the main computing tool for most of the population, making them an ideal tool in many areas. Most of these smartphones are equipped with cutting-edge hardware on their digital cameras, sensors and processors. For this reason, this paper discusses the possibility of using smartphones as an accessible and accurate tool, focusing on the measurement of light, which is an element that has a high impact on human behavior, which promotes conformance and safety, or alters human physiology when it is inappropriate. To carry out this study, three different ways to measure light through smartphones have been checked: the ambient light sensor, the digital camera and an external Bluetooth luxmeter connected with the smartphone. As a result, the accuracy of these methods has been compared to check if they can be used as accurate measurement tools.

  1. Comparative reliability of structured versus unstructured interviews in the admission process of a residency program.

    Science.gov (United States)

    Blouin, Danielle; Day, Andrew G; Pavlov, Andrey

    2011-12-01

    Although never directly compared, structured interviews are reported as being more reliable than unstructured interviews. This study compared the reliability of both types of interview when applied to a common pool of applicants for positions in an emergency medicine residency program. In 2008, one structured interview was added to the two unstructured interviews traditionally used in our resident selection process. A formal job analysis using the critical incident technique guided the development of the structured interview tool. This tool consisted of 7 scenarios assessing 4 of the domains deemed essential for success as a resident in this program. The traditional interview tool assessed 5 general criteria. In addition to these criteria, the unstructured panel members were asked to rate each candidate on the same 4 essential domains rated by the structured panel members. All 3 panels interviewed all candidates. Main outcomes were the overall, interitem, and interrater reliabilities, the correlations between interview panels, and the dimensionality of each interview tool. Thirty candidates were interviewed. The overall reliability reached 0.43 for the structured interview, and 0.81 and 0.71 for the unstructured interviews. Analyses of the variance components showed a high interrater, low interitem reliability for the structured interview, and a high interrater, high interitem reliability for the unstructured interviews. The summary measures from the 2 unstructured interviews were significantly correlated, but neither was correlated with the structured interview. Only the structured interview was multidimensional. A structured interview did not yield a higher overall reliability than both unstructured interviews. The lower reliability is explained by a lower interitem reliability, which in turn is due to the multidimensionality of the interview tool. Both unstructured panels consistently rated a single dimension, even when prompted to assess the 4 specific domains

  2. The interrater and test-retest reliability of the Home Falls and Accidents Screening Tool (HOME FAST) in Malaysia: Using raters with a range of professional backgrounds.

    Science.gov (United States)

    Romli, Muhammad Hibatullah; Mackenzie, Lynette; Lovarini, Meryl; Tan, Maw Pin; Clemson, Lindy

    2017-06-01

    Falls can be a devastating issue for older people living in the community, including those living in Malaysia. Health professionals and community members have a responsibility to ensure that older people have a safe home environment to reduce the risk of falls. Using a standardised screening tool is beneficial to intervene early with this group. The Home Falls and Accidents Screening Tool (HOME FAST) should be considered for this purpose; however, its use in Malaysia has not been studied. Therefore, the aim of this study was to evaluate the interrater and test-retest reliability of the HOME FAST with multiple professionals in the Malaysian context. A cross-sectional design was used to evaluate interrater reliability where the HOME FAST was used simultaneously in the homes of older people by 2 raters and a prospective design was used to evaluate test-retest reliability with a separate group of older people at different times in their homes. Both studies took place in an urban area of Kuala Lumpur. Professionals from 9 professional backgrounds participated as raters in this study, and a group of 51 community older people were recruited for the interrater reliability study and another group of 30 for the test-retest reliability study. The overall agreement was moderate for interrater reliability and good for test-retest reliability. The HOME FAST was consistently rated by different professionals, and no bias was found among the multiple raters. The HOME FAST can be used with confidence by a variety of professionals across different settings. The HOME FAST can become a universal tool to screen for home hazards related to falls. © 2017 John Wiley & Sons, Ltd.

  3. Reliability and Validity Measurement of Sagittal Lumbosacral Quiet Standing Posture with a Smartphone Application in a Mixed Population of 183 College Students and Personnel

    Directory of Open Access Journals (Sweden)

    George A. Koumantakis

    2016-01-01

    Full Text Available Accurate recording of spinal posture with simple and accessible measurement devices in clinical practice may lead to spinal loading optimization in occupations related to prolonged sitting and standing postures. Therefore, the purpose of this study was to establish the level of reliability of sagittal lumbosacral posture in quiet standing and the validity of the method in differentiating between male and female subjects, establishing in parallel a normative database. 183 participants (83 males and 100 females, with no current low back or pelvic pain, were assessed using the “iHandy Level” smartphone application. Intrarater reliability (3 same-day sequential measurements was high for both the lumbar curve (ICC2,1: 0.96, SEM: 2.13°, and MDC95%: 5.9° and the sacral slope (ICC2,1: 0.97, SEM: 1.61°, and MDC95%: 4.46° sagittal alignment. Data analysis for each gender separately confirmed equally high reliability for both male and female participants. Correlation between lumbar curve and sacral slope was high (Pearson’s r=0.86, p<0.001. Between-gender comparisons confirmed the validity of the method to differentiate between male and female lumbar curve and sacral slope angles, with females generally demonstrating greater lumbosacral values (p<0.001. The “iHandy Level” application is a reliable and valid tool in the measurement of lumbosacral quiet standing spinal posture in the sagittal plane.

  4. How to measure distinct components of visual attention fast and reliably

    DEFF Research Database (Denmark)

    Vangkilde, Signe Allerup; Kyllingsbæk, Søren; Habekost, Thomas

    2009-01-01

    Measuring different attentional processes in a fast and reliable way is important in both clinical and experimental settings. However, most tests of visual attention are either lengthy or lack sensitivity, specificity, and reliability. To address this we developed a ten minute test procedure...... for the Swedish Betula-project, a longitudinal study investigating changes in cognitive functions over the adult life span (Nilsson et al., 2004). The test consists of a computer-based letter recognition task with stimulus displays of varied durations followed by pattern masks or a blank screen. The temporal...

  5. About my Child: measuring 'Complexity' in neurodisability. Evidence of reliability and validity.

    Science.gov (United States)

    Ritzema, A M; Lach, L M; Rosenbaum, P; Nicholas, D

    2016-05-01

    About my Child, 26-item version (AMC-26) was developed as a measure of child health 'complexity' and has been proposed as a tool for understanding the functional needs of children and the priorities of families. The current study investigated the reliability and validity of AMC-26 with a sample of caregivers of children with neurodevelopmental disorders (NDD; n = 258) who completed AMC-26 as part of a larger study on parenting children with NDD. A subsample of children from the larger study (n = 49) were assessed using standardized measures of cognitive and adaptive functioning. Factor analysis revealed that a four-component model explained 51.12% of the variance. Cronbach's alpha was calculated for each of the four factors and for the scale as a whole, and ranged from 0.75 to 0.85, suggesting a high level of internal consistency. Construct validity was tested through comparisons with the results of standardized measures of child functioning. Predicted relationships for factors one, two and three were statistically significant and in the expected directions. Predictions for factor four were partially supported. AMC-26 was also expected to serve as an indicator of caregiver distress. Drawing on a sample of caregivers from the larger study (n = 251) the model was found to be significant and explained 23% of the variance in caregiver depressive symptoms (R(2)  = .053, F (1, 249) = 14.06, P child function and child health complexity. Such a measure may help elucidate the relationships between child complexity and family well-being. This is an important avenue for further investigation. © 2016 John Wiley & Sons Ltd.

  6. Reliability and responsiveness of algometry for measuring pressure pain threshold in patients with knee osteoarthritis.

    Science.gov (United States)

    Mutlu, Ebru Kaya; Ozdincler, Arzu Razak

    2015-06-01

    [Purpose] This study aimed to establish the intrarater reliability and responsiveness of a clinically available algometer in patients with knee osteoarthritis as well as to determine the minimum-detectable-change and standard error of measurement of testing to facilitate clinical interpretation of temporal changes. [Subjects] Seventy-three patients with knee osteoarthritis were included. [Methods] Pressure pain threshold measured by algometry was evaluated 3 times at 2-min intervals over 2 clinically relevant sites-mediolateral to the medial femoral tubercle (distal) and lateral to the medial malleolus (local)-on the same day. Intrarater reliability was estimated by intraclass correlation coefficients. The minimum-detectable-change and standard error of measurement were calculated. As a measure of responsiveness, the effect size was calculated for the results at baseline and after treatment. [Results] The intrarater reliability was almost perfect (intraclass correlation coefficient = 0.93-0.97). The standard error of measurement and minimum-detectable-change were 0.70-0.66 and 1.62-1.53, respectively. The pressure pain threshold over the distal site was inadequately responsive in knee osteoarthritis, but the local site was responsive. The effect size was 0.70. [Conclusion] Algometry is reliable and responsive to assess measures of pressure pain threshold for evaluating pain patients with knee osteoarthritis.

  7. Magnetic resonance imaging of shoulders with idiopathic adhesive capsulitis: reliability of measures

    Energy Technology Data Exchange (ETDEWEB)

    Lefevre-Colau, Marie-Martine; Fayad, Fouad; Rannou, Francois; Demaille-Wlodyka, Samantha; Mayoux-Benhamou, Marie-Anne; Poiraudeau, Serge; Revel, Michel [Universite Rene Descartes, Department of Physical and Rehabilitation Medicine, Hopital Cochin (AP-HP), Paris (France); Drape, Jean-Luc; Diche, Thierry; Minvielle, Francois [Hopital Cochin (AP-HP), Department of Radiology B, Paris (France); Fermanian, Jacques [Universite Rene Descartes, Department of Biostatistics, Hopital Necker (AP-HP), Paris (France)

    2005-12-01

    The magnetic resonance imaging (MRI) findings in idiopathic adhesive capsulitis (AC) were compared with those of contralateral healthy shoulders and the reliability of measures assessed. Twenty-six consecutive patients (26 AC and 14 healthy shoulders) were prospectively assessed. The main measurements were thickness of the joint capsule and synovial membrane in the axillary recess and rotator interval in T1-weighted spin-echo sequence enhanced with intravenous (IV) gadolinium chelate (Gd-chelate). Reliability was studied by use of the intraclass correlation coefficient (ICC). The mean thickness of the axillary recess on the coronal plane was 9.0{+-}2.2 mm in AC shoulders and 0.4{+-}0.7 mm in healthy shoulders. The mean thickness of the rotator interval on the sagittal plane was 8.4{+-}2.8 in AC shoulders and 0.6{+-}0.8 mm in healthy shoulders. Interobserver reliability was good for the axillary recess, with ICC values of 0.84 for the coronal plane, and good for the rotator interval, with ICC values of 0.80 for the sagittal plane. MRI with IV Gd-chelate injection can show, with acceptable reliability, signal and thickness abnormalities of the shoulder joint capsule and synovial membrane in AC. (orig.)

  8. Magnetic resonance imaging of shoulders with idiopathic adhesive capsulitis: reliability of measures

    International Nuclear Information System (INIS)

    Lefevre-Colau, Marie-Martine; Fayad, Fouad; Rannou, Francois; Demaille-Wlodyka, Samantha; Mayoux-Benhamou, Marie-Anne; Poiraudeau, Serge; Revel, Michel; Drape, Jean-Luc; Diche, Thierry; Minvielle, Francois; Fermanian, Jacques

    2005-01-01

    The magnetic resonance imaging (MRI) findings in idiopathic adhesive capsulitis (AC) were compared with those of contralateral healthy shoulders and the reliability of measures assessed. Twenty-six consecutive patients (26 AC and 14 healthy shoulders) were prospectively assessed. The main measurements were thickness of the joint capsule and synovial membrane in the axillary recess and rotator interval in T1-weighted spin-echo sequence enhanced with intravenous (IV) gadolinium chelate (Gd-chelate). Reliability was studied by use of the intraclass correlation coefficient (ICC). The mean thickness of the axillary recess on the coronal plane was 9.0±2.2 mm in AC shoulders and 0.4±0.7 mm in healthy shoulders. The mean thickness of the rotator interval on the sagittal plane was 8.4±2.8 in AC shoulders and 0.6±0.8 mm in healthy shoulders. Interobserver reliability was good for the axillary recess, with ICC values of 0.84 for the coronal plane, and good for the rotator interval, with ICC values of 0.80 for the sagittal plane. MRI with IV Gd-chelate injection can show, with acceptable reliability, signal and thickness abnormalities of the shoulder joint capsule and synovial membrane in AC. (orig.)

  9. The development of an online decision support tool for organizational readiness for change.

    Science.gov (United States)

    Khan, Sobia; Timmings, Caitlyn; Moore, Julia E; Marquez, Christine; Pyka, Kasha; Gheihman, Galina; Straus, Sharon E

    2014-05-10

    Much importance has been placed on assessing readiness for change as one of the earliest steps of implementation, but measuring it can be a complex and daunting task. Organizations and individuals struggle with how to reliably and accurately measure readiness for change. Several measures have been developed to help organizations assess readiness, but these are often underused due to the difficulty of selecting the right measure. In response to this challenge, we will develop and test a prototype of a decision support tool that is designed to guide individuals interested in implementation in the selection of an appropriate readiness assessment measure for their setting. A multi-phase approach will be used to develop the decision support tool. First, we will identify key measures for assessing organizational readiness for change from a recently completed systematic review. Included measures will be those developed for healthcare settings (e.g., acute care, public health, mental health) and that have been deemed valid and reliable. Second, study investigators and field experts will engage in a mapping exercise to categorize individual items of included measures according to key readiness constructs from an existing framework. Third, a stakeholder panel will be recruited and consulted to determine the feasibility and relevance of the selected measures using a modified Delphi process. Fourth, findings from the mapping exercise and stakeholder consultation will inform the development of a decision support tool that will guide users in appropriately selecting change readiness measures. Fifth, the tool will undergo usability testing. Our proposed decision support tool will address current challenges in the field of organizational change readiness by aiding individuals in selecting a valid and reliable assessment measure that is relevant to user needs and practice settings. We anticipate that implementers and researchers who use our tool will be more likely to conduct

  10. Reliability of ultrasound for measurement of selected foot structures.

    Science.gov (United States)

    Crofts, G; Angin, S; Mickle, K J; Hill, S; Nester, C J

    2014-01-01

    Understanding the relationship between the lower leg muscles, foot structures and function is essential to explain how disease or injury may relate to changes in foot function and clinical pathology. The aim of this study was to investigate the inter-operator reliability of an ultrasound protocol to quantify features of: rear, mid and forefoot sections of the plantar fascia (PF); flexor hallucis brevis (FHB); flexor digitorum brevis (FDB); abductor hallucis (AbH); flexor digitorum longus (FDL); flexor hallucis longus (FHL); tibialis anterior (TA); and peroneus longus and brevis (PER). A sample of 6 females and 4 males (mean age 29.1 ± 7.2 years, mean BMI 25.5 ± 4.8) was recruited from a university student and staff population. Scans were obtained using a portable Venue 40 musculoskeletal ultrasound system (GE Healthcare UK) with a 5-13 MHz wideband linear array probe with a 12.7 mm × 47.1mm footprint by two operators in the same scanning session. Intraclass Correlation Coefficients (ICC) values for muscle thickness (ICC range 0.90-0.97), plantar fascia thickness (ICC range 0.94-0.98) and cross sectional muscle measurements (ICC range 0.91-0.98) revealed excellent inter-operator reliability. The limits of agreement, relative to structure size, ranged from 9.0% to 17.5% for muscle thickness, 11.0-18.0% for plantar fascia, and 11.0-26.0% for cross sectional area measurements. The ultrasound protocol implemented in this work has been shown to be reliable. It therefore offers the opportunity to quantify the structures concerned and better understand their contributions to foot function. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  11. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    Science.gov (United States)

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  12. Magnetic particle separation technique: a reliable and simple tool for RIA/IRMA and quantitative PCR assay

    International Nuclear Information System (INIS)

    Shen Rongsen; Shen Decun

    1998-01-01

    Five types of magnetic particles without or with aldehyde, amino and carboxyl functional groups, respectively were used to immobilize first or second antibody by three models, i. e. physical adsorption, chemical coupling and immuno-affinity, forming four types of magnetic particle antibodies. The second antibody immobilized on polyacrolein magnetic particles through aldehyde functional groups and the first antibodies immobilized on carboxylic polystyrene magnetic particles through carboxyl functional groups were recommended to apply to RIAs and/or IRMAs. Streptavidin immobilized on commercial magnetic particles through amino functional groups was successfully applied to separating specific PCR product for quantification of human cytomegalovirus. In the paper typical data on reliability of these magnetic particle ligands were reported and simplicity of the magnetic particle separation technique was discussed. The results showed that the technique was a reliable and simple tool for RIA/IRMA and quantitative PCR assay. (author)

  13. Turkish Metalinguistic Awareness Scale: A Validity and Reliability Study

    Science.gov (United States)

    Varisoglu, Behice

    2018-01-01

    The aim of this study is to develop a useful, valid and reliable measurement tool that will help teacher candidates determine their Turkish metalinguistic awareness. During the development of the scale, a pool of items was created by scanning the relevant literature and examining other awareness scales. The materials prepared were re-examined…

  14. How to measure wisdom: content, reliability, and validity of five measures

    Science.gov (United States)

    Glück, Judith; König, Susanne; Naschenweng, Katja; Redzanowski, Uwe; Dorner, Lara; Straßer, Irene; Wiedermann, Wolfgang

    2013-01-01

    Wisdom is a field of growing interest both inside and outside academic psychology, and researchers are increasingly interested in using measures of wisdom in their work. However, wisdom is a highly complex construct, and its various operationalizations are based on quite different definitions. Which measure a researcher chooses for a particular research project may have a strong influence on the results. This study compares four well-established measures of wisdom—the Self-Assessed Wisdom Scale (Webster, 2003, 2007), the Three-Dimensional Wisdom Scale (Ardelt, 2003), the Adult Self-Transcendence Inventory (Levenson et al., 2005), and the Berlin Wisdom Paradigm (Baltes and Smith, 1990; Baltes and Staudinger, 2000)—with respect to content, reliability, factorial structure, and construct validity (relationships to wisdom nomination, interview-based wisdom ratings, and correlates of wisdom). The sample consisted of 47 wisdom nominees and 123 control participants. While none of the measures performed “better” than the others by absolute standards, recommendations are given for researchers to select the most suitable measure for their substantive interests. In addition, a “Brief Wisdom Screening Scale” is introduced that contains those 20 items from the three self-report scales that were most highly correlated with the common factor across the scales. PMID:23874310

  15. Reliability and Measurement Error of Tensiomyography to Assess Mechanical Muscle Function: A Systematic Review.

    Science.gov (United States)

    Martín-Rodríguez, Saúl; Loturco, Irineu; Hunter, Angus M; Rodríguez-Ruiz, David; Munguia-Izquierdo, Diego

    2017-12-01

    Martín-Rodríguez, S, Loturco, I, Hunter, AM, Rodríguez-Ruiz, D, and Munguia-Izquierdo, D. Reliability and measurement error of tensiomyography to assess mechanical muscle function: A systematic review. J Strength Cond Res 31(12): 3524-3536, 2017-Interest in studying mechanical skeletal muscle function through tensiomyography (TMG) has increased in recent years. This systematic review aimed to (a) report the reliability and measurement error of all TMG parameters (i.e., maximum radial displacement of the muscle belly [Dm], contraction time [Tc], delay time [Td], half-relaxation time [½ Tr], and sustained contraction time [Ts]) and (b) to provide critical reflection on how to perform accurate and appropriate measurements for informing clinicians, exercise professionals, and researchers. A comprehensive literature search was performed of the Pubmed, Scopus, Science Direct, and Cochrane databases up to July 2017. Eight studies were included in this systematic review. Meta-analysis could not be performed because of the low quality of the evidence of some studies evaluated. Overall, the review of the 9 studies involving 158 participants revealed high relative reliability (intraclass correlation coefficient [ICC]) for Dm (0.91-0.99); moderate-to-high ICC for Ts (0.80-0.96), Tc (0.70-0.98), and ½ Tr (0.77-0.93); and low-to-high ICC for Td (0.60-0.98), independently of the evaluated muscles. In addition, absolute reliability (coefficient of variation [CV]) was low for all TMG parameters except for ½ Tr (CV = >20%), whereas measurement error indexes were high for this parameter. In conclusion, this study indicates that 3 of the TMG parameters (Dm, Td, and Tc) are highly reliable, whereas ½ Tr demonstrate insufficient reliability, and thus should not be used in future studies.

  16. Evaluation of structural reliability using simulation methods

    Directory of Open Access Journals (Sweden)

    Baballëku Markel

    2015-01-01

    Full Text Available Eurocode describes the 'index of reliability' as a measure of structural reliability, related to the 'probability of failure'. This paper is focused on the assessment of this index for a reinforced concrete bridge pier. It is rare to explicitly use reliability concepts for design of structures, but the problems of structural engineering are better known through them. Some of the main methods for the estimation of the probability of failure are the exact analytical integration, numerical integration, approximate analytical methods and simulation methods. Monte Carlo Simulation is used in this paper, because it offers a very good tool for the estimation of probability in multivariate functions. Complicated probability and statistics problems are solved through computer aided simulations of a large number of tests. The procedures of structural reliability assessment for the bridge pier and the comparison with the partial factor method of the Eurocodes have been demonstrated in this paper.

  17. The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals

    Energy Technology Data Exchange (ETDEWEB)

    Fuller, Joel T.; Buckley, Jonathan D.; Tsiros, Margarita D.; Thewlis, Dominic [University of South Australia, Alliance for Research in Exercise, Nutrition and Activity (ARENA), Sansom Institute for Health Research, GPO Box 2471, Adelaide, South Australia (Australia); Archer, Jane [University of South Australia, Medical Radiation, School of Health Sciences, Adelaide (Australia)

    2016-01-15

    To investigate the reliability of a simple, efficient technique for measuring bone mineral density (BMD) in the metatarsals using dual-energy X-ray absorptiometry (DXA). BMD of the right foot of 32 trained male distance runners was measured using a DXA scanner with the foot in the plantar position. Separate regions of interest (ROI) were used to assess the BMD of each metatarsal shaft (1st-5th) for each participant. ROI analysis was repeated by the same investigator to determine within-scan intra-rater reliability and by a different investigator to determine within-scan inter-rater reliability. Repeat DXA scans were undertaken for ten participants to assess between-scan intra-rater reliability. Assessment of BMD was consistently most reliable for the first metatarsal across all domains of reliability assessed (intra-class correlation coefficient [ICC] ≥0.97; coefficient of variation [CV] ≤1.5 %; limits of agreement [LOA] ≤4.2 %). Reasonable levels of intra-rater reliability were also achieved for the second and fifth metatarsals (ICC ≥0.90; CV ≤4.2 %; LOA ≤11.9 %). Poorer levels of reliability were demonstrated for the third (ICC ≥0.64; CV ≤8.2 %; LOA ≤23.6 %) and fourth metatarsals (ICC ≥0.67; CV ≤9.6 %; LOA ≤27.5 %). BMD was greatest in the first and second metatarsals (P < 0.01). Reliable measurements of BMD were achieved for the first, second and fifth metatarsals. (orig.)

  18. The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals

    International Nuclear Information System (INIS)

    Fuller, Joel T.; Buckley, Jonathan D.; Tsiros, Margarita D.; Thewlis, Dominic; Archer, Jane

    2016-01-01

    To investigate the reliability of a simple, efficient technique for measuring bone mineral density (BMD) in the metatarsals using dual-energy X-ray absorptiometry (DXA). BMD of the right foot of 32 trained male distance runners was measured using a DXA scanner with the foot in the plantar position. Separate regions of interest (ROI) were used to assess the BMD of each metatarsal shaft (1st-5th) for each participant. ROI analysis was repeated by the same investigator to determine within-scan intra-rater reliability and by a different investigator to determine within-scan inter-rater reliability. Repeat DXA scans were undertaken for ten participants to assess between-scan intra-rater reliability. Assessment of BMD was consistently most reliable for the first metatarsal across all domains of reliability assessed (intra-class correlation coefficient [ICC] ≥0.97; coefficient of variation [CV] ≤1.5 %; limits of agreement [LOA] ≤4.2 %). Reasonable levels of intra-rater reliability were also achieved for the second and fifth metatarsals (ICC ≥0.90; CV ≤4.2 %; LOA ≤11.9 %). Poorer levels of reliability were demonstrated for the third (ICC ≥0.64; CV ≤8.2 %; LOA ≤23.6 %) and fourth metatarsals (ICC ≥0.67; CV ≤9.6 %; LOA ≤27.5 %). BMD was greatest in the first and second metatarsals (P < 0.01). Reliable measurements of BMD were achieved for the first, second and fifth metatarsals. (orig.)

  19. The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals.

    Science.gov (United States)

    Fuller, Joel T; Archer, Jane; Buckley, Jonathan D; Tsiros, Margarita D; Thewlis, Dominic

    2016-01-01

    To investigate the reliability of a simple, efficient technique for measuring bone mineral density (BMD) in the metatarsals using dual-energy X-ray absorptiometry (DXA). BMD of the right foot of 32 trained male distance runners was measured using a DXA scanner with the foot in the plantar position. Separate regions of interest (ROI) were used to assess the BMD of each metatarsal shaft (1st-5th) for each participant. ROI analysis was repeated by the same investigator to determine within-scan intra-rater reliability and by a different investigator to determine within-scan inter-rater reliability. Repeat DXA scans were undertaken for ten participants to assess between-scan intra-rater reliability. Assessment of BMD was consistently most reliable for the first metatarsal across all domains of reliability assessed (intra-class correlation coefficient [ICC] ≥0.97; coefficient of variation [CV] ≤1.5%; limits of agreement [LOA] ≤4.2%). Reasonable levels of intra-rater reliability were also achieved for the second and fifth metatarsals (ICC ≥0.90; CV ≤4.2%; LOA ≤11.9%). Poorer levels of reliability were demonstrated for the third (ICC ≥0.64; CV ≤8.2%; LOA ≤23.6%) and fourth metatarsals (ICC ≥0.67; CV ≤9.6%; LOA ≤27.5%). BMD was greatest in the first and second metatarsals (P Reliable measurements of BMD were achieved for the first, second and fifth metatarsals.

  20. Ovarian and cervical cancer awareness: development of two validated measurement tools.

    Science.gov (United States)

    Simon, Alice E; Wardle, Jane; Grimmett, Chloe; Power, Emily; Corker, Elizabeth; Menon, Usha; Matheson, Lauren; Waller, Jo

    2012-07-01

    The aim of the study was to develop and validate measures of awareness of symptoms and risk factors for ovarian and cervical cancer (Ovarian and Cervical Cancer Awareness Measures). Potentially relevant items were extracted from the literature and generated by experts. Four validation studies were carried out to establish reliability and validity. Women aged 21-67 years (n=146) and ovarian and cervical cancer experts (n=32) were included in the studies. Internal reliability was assessed psychometrically. Test-retest reliability was assessed over a 1-week interval. To establish construct validity, Cancer Awareness Measure (CAM) scores of cancer experts were compared with equally well-educated comparison groups. Sensitivity to change was tested by randomly assigning participants to read either a leaflet giving information about ovarian/cervical cancer or a leaflet with control information, and then completing the ovarian/cervical CAM. Internal reliability (Cronbach's α=0.88 for the ovarian CAM and α=0.84 for the cervical CAM) and test-retest reliability (r=0.84 and r=0.77 for the ovarian and cervical CAMs, respectively) were both high. Validity was demonstrated with cancer experts achieving higher scores than controls [ovarian CAM: t(36)= -5.6, pcancer leaflet scored higher than those who received a control leaflet [ovarian CAM: t(49)=7.5, pcancer awareness in the general population.

  1. Assessing Reliability and Validity of the "GroPromo" Audit Tool for Evaluation of Grocery Store Marketing and Promotional Environments

    Science.gov (United States)

    Kerr, Jacqueline; Sallis, James F.; Bromby, Erica; Glanz, Karen

    2012-01-01

    Objective: To evaluate reliability and validity of a new tool for assessing the placement and promotional environment in grocery stores. Methods: Trained observers used the "GroPromo" instrument in 40 stores to code the placement of 7 products in 9 locations within a store, along with other promotional characteristics. To test construct validity,…

  2. Research on reliability measures of the main transformer and GIS equipment manufacturing process

    International Nuclear Information System (INIS)

    Wu Honglong

    2014-01-01

    Based on the accidents of the main transformer GIS equipment and the accidents of the high voltage switch equipment, combined with the main transformer switch equipment maintenance experience and electrical theory, the reliability measures of the main transformer GIS equipment during manufacturing stage are studied and improved. Six successful reliability measures are identified: 1) design properly and check the ability of transformer for anti short circuit; 2) choose mature and reliable main transformer HV bushing; 3) choose GIS switch operation mechanism of high quality and reliability; 4) ensure that the insulation margin through tests piece by piece on withstand voltage and partial discharge of the GIS equipment insulation; 5) take test measures such as GIS conductor, shell polishing witness process and full form lightning impulse, to find out and eliminate the defects of abnormal electric field distribution; 6) Anti VFTO design for the main transformer connected with GIS with the voltage of 500 kV should be considered, and its anti VFTO ability to meet the safe operation under VFTO requirements should be checked. This paper proposed 2 new measures: 1) the main transformer insulation material quality standard is determined not only by its high dielectric strength, but more importantly by the homogeneous dielectric electric strength. Insulating Materials with a high and also uniform dielectric strength should be chosen. 2) During the silver-coating stage of the GIS equipment conductor, QC group activities should be organized to ensure that the plating layer quality, and the current lap surface DC resistance measurements should be supervised and witnessed to ensure the quality of the conductor contact surface. These measures are verified in Fuqing project of GIS main transformer equipment manufacturing process, and their effectiveness is proven. (author)

  3. The victorian institute of sports assessment - achilles questionnaire (visa-a) - a reliable tool for measuring achilles tendinopathy

    DEFF Research Database (Denmark)

    Iversen, Jonas Vestergård; Bartels, Else Marie; Langberg, Henning

    2012-01-01

    Achilles tendinopathy (AT) is a common pathology and the aetiology is unknown. For valid and reliable assessment The Victorian Institute of Sports Assessment has designed a self-administered Achilles questionnaire, the VISA-A. The aim of the present study was to evaluate VISA-A as an outcome...

  4. Comparing the performance of three digital forensic tools

    Directory of Open Access Journals (Sweden)

    Brian Cusack

    Full Text Available Software used for digital forensic investigations requires to be verified against reliability and validity criteria. In this paper, three well known tools are tested against the mandatory features of digital forensic tools published by the National Institute of Standards (NIST. It was found that a variation in performance existed between the tools, with all having measureable areas of non performance. The findings have an impact on the professional use of the tools and illustrate the need for benchmarking and testing of the tools before use.

  5. Reliability and Validity of Selected PROMIS Measures in People with Rheumatoid Arthritis.

    Directory of Open Access Journals (Sweden)

    Susan J Bartlett

    Full Text Available To evaluate the reliability and validity of 11 PROMIS measures to assess symptoms and impacts identified as important by people with rheumatoid arthritis (RA.Consecutive patients (N = 177 in an observational study completed PROMIS computer adapted tests (CATs and a short form (SF assessing pain, fatigue, physical function, mood, sleep, and participation. We assessed test-test reliability and internal consistency using correlation and Cronbach's alpha. We assessed convergent validity by examining Pearson correlations between PROMIS measures and existing measures of similar domains and known groups validity by comparing scores across disease activity levels using ANOVA.Participants were mostly female (82% and white (83% with mean (SD age of 56 (13 years; 24% had ≤ high school, 29% had RA ≤ 5 years with 13% ≤ 2 years, and 22% were disabled. PROMIS Physical Function, Pain Interference and Fatigue instruments correlated moderately to strongly (rho's ≥ 0.68 with corresponding PROs. Test-retest reliability ranged from .725-.883, and Cronbach's alpha from .906-.991. A dose-response relationship with disease activity was evident in Physical Function with similar trends in other scales except Anger.These data provide preliminary evidence of reliability and construct validity of PROMIS CATs to assess RA symptoms and impacts, and feasibility of use in clinical care. PROMIS instruments captured the experiences of RA patients across the broad continuum of RA symptoms and function, especially at low disease activity levels. Future research is needed to evaluate performance in relevant subgroups, assess responsiveness and identify clinically meaningful changes.

  6. Assessment of intra-interobserver reliability of the sonographic optic nerve sheath diameter measurement

    Directory of Open Access Journals (Sweden)

    Tuba Cimilli Ozturk

    2015-08-01

    Full Text Available Diagnosis and measuring the level of increase in intracranial pressure (ICP is critical, especially for the management of trauma patients in the emergency department and intensive care unit. However, measurements are operator-dependent as in all of the sonographic diagnoses. The aim of this study is to assess the operator variations in the measurement of optic nerve sheath diameter (ONSD. There were four emergency medicine specialists involved in the study. Each had at least 1 year of experience of ultrasound scans and performed at least 25 prior ocular scans examining the ONSD. Two measurements were made 1 week apart from both axial and longitudinal planes. Sixty healthy adults were involved in the study and every investigator obtained four measurements from each. Intra-interobserver reliabilities were tested. The investigators performed 60 ocular ultrasounds on individual healthy adults and obtained two measurements in axial and longitudinal planes 1 week apart. Therefore, 960 measurements were analyzed. The levels of compatibilities for most of the measurements were found at acceptable levels statistically. However, it is not possible to say that there was a perfect compatibility among the sonographers according to the previously conducted reliability studies of ultrasound measurements. According to our results, it is hard to say that sonographic measurement of the ONSD is a highly reliable method both in longitudinal and transverse planes.

  7. Wii Balance Board: Reliability and Clinical Use in Assessment of Balance in Healthy Elderly Women.

    Science.gov (United States)

    Monteiro-Junior, Renato Sobral; Ferreira, Arthur Sá; Puell, Vivian Neiva; Lattari, Eduardo; Machado, Sérgio; Otero Vaghetti, César Augusto; da Silva, Elirez Bezerra

    2015-01-01

    Force plate is considered gold standard tool to assess body balance. However the Wii Balance Board (WBB) platform is a trustworthy equipment to assess stabilometric components in young people. Thus, we aim to examine the reliability of measures of center of pressure with WBB in healthy elderly women. Twenty one healthy and physically active women were enrolled in the study (age: 64 ± 7 years; body mass index: 29 ± 5 kg/m2. The WBB was used to assess the center of pressure measures in the individuals. Pressure was linearly applied to different points to test the platform precision. Three assessments were performed, with two of them being held on the same day at a 5- to 10-minute interval, and the third one was performed 48 h later. A linear regression analysis was used to find out linearity, while the intraclass correlation coefficient was used to assess reliability. The platform precision was adequate (R2 = 0.997, P = 0.01). Center of pressure measures showed an excellent reliability (all intraclass correlation coefficient values were > 0.90; p < 0.01). The WBB is a precise and reliable tool of body stability quantitative measure in healthy active elderly women and its use should be encouraged in clinical settings.

  8. Workplace spirituality in indian organisations: construction of reliable and valid measurement scale

    Directory of Open Access Journals (Sweden)

    Rabindra Kumar Pradhan

    2017-05-01

    Full Text Available The purpose of the paper was to develop and validate a comprehensive tool for measuring workplace spirituality. On the basis of literature, feedback from academic and industry professionals, a heuristic framework along with a scale on workplace spirituality was proposed and a questionnaire was developed. The instrument obtained empirical views from experts on its dimensions and statements. Content validity ratio (CVR of the instrument was carried out and the retained items were taken for field survey. Three hundred and sixty one executive respondents employed in manufacturing and service organisations in Indian subcontinent responded to the 44 items scale assessing different facets of spirituality at workplace. This helped to validate the factors of workplace spirituality and optimize the contents of the proposed instrument with the help of structural equation modelling. Exploratory factor analysis revealed four distinct factors that constitute the new instrument of workplace spirituality: spiritual orientation, compassion, meaningful work, and alignment of values. Reliability analysis reported high level of internal consistency of the total scale (α = .78 and the five subscales (α’s ranging from .75 to .87. Finally, 30 items were retained with four important factors of Workplace Spirituality Scale.

  9. Travel reliability inventory for Chicago.

    Science.gov (United States)

    2013-04-01

    The overarching goal of this research project is to enable state DOTs to document and monitor the reliability performance : of their highway networks. To this end, a computer tool, TRIC, was developed to produce travel reliability inventories from : ...

  10. Reliability of Pressure Ulcer Rates: How Precisely Can We Differentiate Among Hospital Units, and Does the Standard Signal‐Noise Reliability Measure Reflect This Precision?

    Science.gov (United States)

    Cramer, Emily

    2016-01-01

    Abstract Hospital performance reports often include rankings of unit pressure ulcer rates. Differentiating among units on the basis of quality requires reliable measurement. Our objectives were to describe and apply methods for assessing reliability of hospital‐acquired pressure ulcer rates and evaluate a standard signal‐noise reliability measure as an indicator of precision of differentiation among units. Quarterly pressure ulcer data from 8,199 critical care, step‐down, medical, surgical, and medical‐surgical nursing units from 1,299 US hospitals were analyzed. Using beta‐binomial models, we estimated between‐unit variability (signal) and within‐unit variability (noise) in annual unit pressure ulcer rates. Signal‐noise reliability was computed as the ratio of between‐unit variability to the total of between‐ and within‐unit variability. To assess precision of differentiation among units based on ranked pressure ulcer rates, we simulated data to estimate the probabilities of a unit's observed pressure ulcer rate rank in a given sample falling within five and ten percentiles of its true rank, and the probabilities of units with ulcer rates in the highest quartile and highest decile being identified as such. We assessed the signal‐noise measure as an indicator of differentiation precision by computing its correlations with these probabilities. Pressure ulcer rates based on a single year of quarterly or weekly prevalence surveys were too susceptible to noise to allow for precise differentiation among units, and signal‐noise reliability was a poor indicator of precision of differentiation. To ensure precise differentiation on the basis of true differences, alternative methods of assessing reliability should be applied to measures purported to differentiate among providers or units based on quality. © 2016 The Authors. Research in Nursing & Health published by Wiley Periodicals, Inc. PMID:27223598

  11. Image fusion tool: Validation by phantom measurements

    International Nuclear Information System (INIS)

    Zander, A.; Geworski, L.; Richter, M.; Ivancevic, V.; Munz, D.L.; Muehler, M.; Ditt, H.

    2002-01-01

    Aim: Validation of a new image fusion tool with regard to handling, application in a clinical environment and fusion precision under different acquisition and registration settings. Methods: The image fusion tool investigated allows fusion of imaging modalities such as PET, CT, MRI. In order to investigate fusion precision, PET and MRI measurements were performed using a cylinder and a body contour-shaped phantom. The cylinder phantom (diameter and length 20 cm each) contained spheres (10 to 40 mm in diameter) which represented 'cold' or 'hot' lesions in PET measurements. The body contour-shaped phantom was equipped with a heart model containing two 'cold' lesions. Measurements were done with and without four external markers placed on the phantoms. The markers were made of plexiglass (2 cm diameter and 1 cm thickness) and contained a Ga-Ge-68 core for PET and Vitamin E for MRI measurements. Comparison of fusion results with and without markers was done visually and by computer assistance. This algorithm was applied to the different fusion parameters and phantoms. Results: Image fusion of PET and MRI data without external markers yielded a measured error of 0 resulting in a shift at the matrix border of 1.5 mm. Conclusion: The image fusion tool investigated allows a precise fusion of PET and MRI data with a translation error acceptable for clinical use. The error is further minimized by using external markers, especially in the case of missing anatomical orientation. Using PET the registration error depends almost only on the low resolution of the data

  12. Testing the reliability and efficiency of the pilot Mixed Methods Appraisal Tool (MMAT) for systematic mixed studies review.

    Science.gov (United States)

    Pace, Romina; Pluye, Pierre; Bartlett, Gillian; Macaulay, Ann C; Salsberg, Jon; Jagosh, Justin; Seller, Robbyn

    2012-01-01

    Systematic literature reviews identify, select, appraise, and synthesize relevant literature on a particular topic. Typically, these reviews examine primary studies based on similar methods, e.g., experimental trials. In contrast, interest in a new form of review, known as mixed studies review (MSR), which includes qualitative, quantitative, and mixed methods studies, is growing. In MSRs, reviewers appraise studies that use different methods allowing them to obtain in-depth answers to complex research questions. However, appraising the quality of studies with different methods remains challenging. To facilitate systematic MSRs, a pilot Mixed Methods Appraisal Tool (MMAT) has been developed at McGill University (a checklist and a tutorial), which can be used to concurrently appraise the methodological quality of qualitative, quantitative, and mixed methods studies. The purpose of the present study is to test the reliability and efficiency of a pilot version of the MMAT. The Center for Participatory Research at McGill conducted a systematic MSR on the benefits of Participatory Research (PR). Thirty-two PR evaluation studies were appraised by two independent reviewers using the pilot MMAT. Among these, 11 (34%) involved nurses as researchers or research partners. Appraisal time was measured to assess efficiency. Inter-rater reliability was assessed by calculating a kappa statistic based on dichotomized responses for each criterion. An appraisal score was determined for each study, which allowed the calculation of an overall intra-class correlation. On average, it took 14 min to appraise a study (excluding the initial reading of articles). Agreement between reviewers was moderate to perfect with regards to MMAT criteria, and substantial with respect to the overall quality score of appraised studies. The MMAT is unique, thus the reliability of the pilot MMAT is promising, and encourages further development. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  14. Web-based tools can be used reliably to detect patients with major depressive disorder and subsyndromal depressive symptoms

    Directory of Open Access Journals (Sweden)

    Tsai Shih-Jen

    2007-04-01

    Full Text Available Abstract Background Although depression has been regarded as a major public health problem, many individuals with depression still remain undetected or untreated. Despite the potential for Internet-based tools to greatly improve the success rate of screening for depression, their reliability and validity has not been well studied. Therefore the aim of this study was to evaluate the test-retest reliability and criterion validity of a Web-based system, the Internet-based Self-assessment Program for Depression (ISP-D. Methods The ISP-D to screen for major depressive disorder (MDD, minor depressive disorder (MinD, and subsyndromal depressive symptoms (SSD was developed in traditional Chinese. Volunteers, 18 years and older, were recruited via the Internet and then assessed twice on the online ISP-D system to investigate the test-retest reliability of the test. They were subsequently prompted to schedule face-to-face interviews. The interviews were performed by the research psychiatrists using the Mini-International Neuropsychiatric Interview and the diagnoses made according to DSM-IV diagnostic criteria were used for the statistics of criterion validity. Kappa (κ values were calculated to assess test-retest reliability. Results A total of 579 volunteer subjects were administered the test. Most of the subjects were young (mean age: 26.2 ± 6.6 years, female (77.7%, single (81.6%, and well educated (61.9% college or higher. The distributions of MDD, MinD, SSD and no depression specified were 30.9%, 7.4%, 15.2%, and 46.5%, respectively. The mean time to complete the ISP-D was 8.89 ± 6.77 min. One hundred and eighty-four of the respondents completed the retest (response rate: 31.8%. Our analysis revealed that the 2-week test-retest reliability for ISP-D was excellent (weighted κ = 0.801. Fifty-five participants completed the face-to-face interview for the validity study. The sensitivity, specificity, positive, and negative predictive values for major

  15. Measuring the airway in 3 dimensions: a reliability and accuracy study.

    Science.gov (United States)

    El, Hakan; Palomo, Juan Martin

    2010-04-01

    The aim of the study was to compare the reliability and accuracy of 3 commercially available digital imaging and communications in medicine (DICOM) viewers for measuring upper airway volumes. Thirty cone-beam computed tomography scans were randomly selected, and the upper airway volumes were calculated for both oropharynx and nasal passage. Dolphin3D (version 11, Dolphin Imaging & Management Solutions, Chatsworth, Calif), InVivoDental (version 4.0.70, Anatomage, San Jose, Calif), and OnDemand3D (version 1.0.1.8407, CyberMed, Seoul, Korea) were compared with a previously tested manual segmentation program called OrthoSegment (OS) (developed at the Department of Orthodontics at Case Western Reserve University, Cleveland, Ohio). The measurements were repeated after 2 weeks, and the ICC was used for the reliability tests. All commercially available programs were compared with the OS program by using regression analysis. The Pearson correlation was used to evaluate the correlation between the OS and the automatic segmentation programs. The reliability was high for all programs. The highest correlation found was between the OS and Dolphin3D for the oropharynx, and between the OS and InVivoDental for nasal passage volume. A high correlation was found for all programs, but the results also showed statistically significant differences compared with the OS program. The programs also had inconsistencies among themselves. The 3 commercially available DICOM viewers are highly reliable in their airway volume calculations and showed high correlation of results but poor accuracy, suggesting systematic errors. Copyright 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  16. Reliability and responsiveness of the Self-Efficacy in Assessing, Training and Spotting wheelchair skills (SEATS) outcome measure.

    Science.gov (United States)

    Rushton, Paula W; Smith, Emma M; Miller, William C; Kirby, R Lee; Daoust, Geneviève

    2018-01-31

    The aim of this study was to evaluate the internal consistency, test-retest reliability and responsiveness of the Self-Efficacy in Assessing, Training and Spotting manual wheelchair skills (SEATS-M) and Self-Efficacy in Assessing, Training and Spotting power wheelchair skills (SEATS-P). A 2-week test-retest design was used with a convenience sample of occupational and physical therapists who worked at a provincial rehabilitation centre (inpatient and outpatient services). Sixteen participants completed the SEATS-M and 18 participants completed the SEATS-P. For the SEATS-M assessment, training, spotting and documentation sections, Cronbach's alpha coefficients ranged from 0.90 to 0.97, the 2-week intraclass correlation coefficients (ICC 1,1 ) ranged from 0.81 to 0.95, the standard error of measurements (SEM) ranged from 5.06 to 8.70 and the smallest real differences (SRD) ranged from 6.24 to 8.18. For the SEATS-P assessment, training, spotting and documentation sections, Cronbach's alpha coefficients ranged from 0.83 to 0.92, the ICCs ranged from 0.72 to 0.86, the SEMs ranged from 4.54 to 8.91 and the SRDs ranged from 5.90 to 8.27. There is preliminary evidence that both the SEATS-M and the SEATS-P have high internal consistency, good test-retest reliability and support for responsiveness. These tools can be used in evaluating clinician self-efficacy with assessing, training, spotting and documenting wheelchair skills included on the Wheelchair Skills Test. Implications for Rehabilitation There is preliminary evidence that the SEATS-M and SEATS-P are reliable and responsive outcome measures that can be used to evaluate the self-efficacy of clinicians to administer the Wheelchair Skills Program. Measurement of clinicians' self-efficacy in this area of practice may enable an enhanced understanding of the areas in which clinicians lack self-efficacy, thereby informing the development of improved knowledge translation interventions.

  17. Human factor reliability program

    International Nuclear Information System (INIS)

    Knoblochova, L.

    2017-01-01

    The human factor's reliability program was at Slovenske elektrarne, a.s. (SE) nuclear power plants. introduced as one of the components Initiatives of Excellent Performance in 2011. The initiative's goal was to increase the reliability of both people and facilities, in response to 3 major areas of improvement - Need for improvement of the results, Troubleshooting support, Supporting the achievement of the company's goals. The human agent's reliability program is in practice included: - Tools to prevent human error; - Managerial observation and coaching; - Human factor analysis; -Quick information about the event with a human agent; -Human reliability timeline and performance indicators; - Basic, periodic and extraordinary training in human factor reliability(authors)

  18. Reliability of agriculture universal joint shafts based on temperature measuring in universal joint bearing assemblies

    Directory of Open Access Journals (Sweden)

    Аleksandar Asonja

    2015-03-01

    Full Text Available This paper presents a research into reliability calculations of agriculture double universal joint shafts based on temperature measuring in cardan-type universal joint bearing assemblies. Special laboratory equipment was developed for this research which is presented in the paper. The objective of this research was to test the real life span of universal joint shafts in the laboratory and in field, to obtain the results which can be used to improve the reliability of universal joint shafts. If the presented research were used along with maintenance measures recommended in the paper and with proper use, the level of reliability of the shafts would be 2.1 times higher. The presented results of the research showed that needle bearings, i.e. bearing assemblies of the joints, are the most critical elements on universal joint shafts and are possible causes of their lower reliability. The second universal joint is the part with the lowest reliability in the observed technical system.

  19. Harmonization process and reliability assessment of anthropometric measurements in the elderly EXERNET multi-centre study.

    Directory of Open Access Journals (Sweden)

    Alba Gómez-Cabello

    Full Text Available BACKGROUND: The elderly EXERNET multi-centre study aims to collect normative anthropometric data for old functionally independent adults living in Spain. PURPOSE: To describe the standardization process and reliability of the anthropometric measurements carried out in the pilot study and during the final workshop, examining both intra- and inter-rater errors for measurements. MATERIALS AND METHODS: A total of 98 elderly from five different regions participated in the intra-rater error assessment, and 10 different seniors living in the city of Toledo (Spain participated in the inter-rater assessment. We examined both intra- and inter-rater errors for heights and circumferences. RESULTS: For height, intra-rater technical errors of measurement (TEMs were smaller than 0.25 cm. For circumferences and knee height, TEMs were smaller than 1 cm, except for waist circumference in the city of Cáceres. Reliability for heights and circumferences was greater than 98% in all cases. Inter-rater TEMs were 0.61 cm for height, 0.75 cm for knee-height and ranged between 2.70 and 3.09 cm for the circumferences measured. Inter-rater reliabilities for anthropometric measurements were always higher than 90%. CONCLUSION: The harmonization process, including the workshop and pilot study, guarantee the quality of the anthropometric measurements in the elderly EXERNET multi-centre study. High reliability and low TEM may be expected when assessing anthropometry in elderly population.

  20. Validity and inter-observer reliability of subjective hand-arm vibration assessments

    NARCIS (Netherlands)

    Coenen, P.; Formanoy, M.; Douwes, M.; Bosch, T.; Kraker, H. de

    2014-01-01

    Exposure to mechanical vibrations at work (e.g., due to handling powered tools) is a potential occupational risk as it may cause upper extremity complaints. However, reliable and valid assessment methods for vibration exposure at work are lacking. Measuring hand-arm vibration objectively is often

  1. Validity and Reliability of Dynamic Visual Acuity (DVA) Measurement During Walking

    Science.gov (United States)

    Deshpande, Nandini; Peters, Brian T.; Bloomberg, Jacob J.

    2014-01-01

    DVA is primarily subserved by the vestibulo-ocular reflex mechanism. Individuals with vestibular hypofunction commonly experience highly debilitating illusory movement or blurring of visual images during daily activities possibly, due to impaired DVA. Even without pathologies, gradual age-related morphological deterioration is evident in all components of the vestibular system. We examined the construct validity to detect age-related differences and test-retest reliability of DVA measurements performed during walking. METHODS: Healthy adults were recruited into 3 groups: 1. young (20-39years, n=18), 2. middle-aged (40-59years, n=14), and 3. older adults (60-80years, n=15). Randomly selected seven participants from each group (n=21) participated in retesting. Participants were excluded if they had a history of vestibular or neuromuscular pathologies, dizziness/vertigo or >1 falls in the past year. Older persons with MMSE scores reliability. RESULTS: The three age groups were not different in their height, weight and normal walking speed (p>0.05). The post hoc analyses for DVA measurements demonstrated that each group was significantly different from the other two groups for Near as well as FarDVA (preliability. FarDVA at 0.8 m/s and 1.0 m/s demonstrated good test-retest reliability (ICCs 0.71 and 0.77, respectively).

  2. The Reliability of Isometer 2 Device in Measuring of Cervical Flexor and Extensor Muscles Strength

    Directory of Open Access Journals (Sweden)

    Asghar Reza Soltan-Zadeh

    2006-07-01

    Full Text Available Objective: The strength of a group of muscles can be measured by muscle strength test, employing a force measuring instrument. In order to monitor the effectiveness of a therapeutic or training programs we need a reliable technique which is also accurate in repeated measurements. The purpose of this study was to examine the reliability of an isometric neck muscle force measurement device.  Materials & Methods: Thirty seven healthy non athlete subjects (18 males and 19 females, aged 18-25 participated in this analytical study. The maximal isometric contractions of the neck extensor and flexor muscles were measured in different times and different days and by two different testers. A new sensitive “load cell” was applied to our previously designed neck muscle force measurement apparatus. Results: The results of the inter-trail, test retest, and inter rater reliability (0.86 < ICC < 0.98 , 2.2< Sw <5.1 N indicated that the neck muscle force measurements were highly repeatable and less variable between measurements. There were no statistically significant differences in neck muscle force measurements, between times, between days and between retsters. Maximum isometric contractions were significantly higher in males than in the females (p < 0.001. Women’s neck muscle strengths were 30.8% and 46.1% of men in cervical extension and cervical flexion. Conclusion: In this study we used a new model (Isometer 2 of our previous apparatus (Isometer. The isometric strength of neck flexor and extensor muscles which was measured by Isometer 2 appeared to be a reliable and useful method for measuring the force of the neck extensor and flexor muscles.

  3. Reliability of four experimental mechanical pain tests in children

    Directory of Open Access Journals (Sweden)

    Soee AL

    2013-02-01

    Full Text Available Ann-Britt L Soee,1 Lise L Thomsen,2 Birte Tornoe,1,3 Liselotte Skov11Department of Pediatrics, Children’s Headache Clinic, Copenhagen University Hospital Herlev, Copenhagen, Denmark; 2Department of Neuropediatrics, Juliane Marie Centre, Copenhagen University Hospital Rigshospitalet, København Ø, Denmark; 3Department of Physiotherapy, Medical Department O, Copenhagen University Hospital Herlev, Herlev, DenmarkPurpose: In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT in healthy children. Furthermore, the aim was also to study the intersession reliability of the following four tests: (1 Total Tenderness Score; (2 PPT; (3 Visual Analog Scale score at suprapressure pain threshold; and (4 area under the curve (stimulus–response functions for pressure versus pain.Participants and methods: Twenty-five healthy school children, 8–14 years of age, participated. Test 2, PPT, was repeated three times at 2 minute intervals on the same day to estimate PPT intrasession reliability using Cronbach’s alpha. Tests 1–4 were repeated after median 21 (interquartile range 10.5–22 days, and Pearson’s correlation coefficient was used to describe the intersession reliability.Results: The PPT test was precise and reliable (Cronbach’s alpha ≥ 0.92. All tests showed a good to excellent correlation between days (intersessions r = 0.66–0.81. There were no indications of significant systematic differences found in any of the four tests between days.Conclusion: All tests seemed to be reliable measurements in pain evaluation in healthy children aged 8–14 years. Given the small sample size, this conclusion needs to be confirmed in future studies.Keywords: repeatability, intraindividual reliability, pressure pain threshold, pain measurement, algometer

  4. Fatigue is a reliable, sensitive and unique outcome measure in rheumatoid arthritis.

    LENUS (Irish Health Repository)

    Minnock, Patricia

    2009-12-01

    Fatigue is an important symptom in patients with RA. Measurement of fatigue in clinical trials and in clinical practice requires scales that are reproducible, sensitive to change and practical. This study examined the reliability and sensitivity to change of fatigue and its relative independence as an outcome measure in RA.

  5. A new reliability measure based on specified minimum distances before the locations of random variables in a finite interval

    International Nuclear Information System (INIS)

    Todinov, M.T.

    2004-01-01

    A new reliability measure is proposed and equations are derived which determine the probability of existence of a specified set of minimum gaps between random variables following a homogeneous Poisson process in a finite interval. Using the derived equations, a method is proposed for specifying the upper bound of the random variables' number density which guarantees that the probability of clustering of two or more random variables in a finite interval remains below a maximum acceptable level. It is demonstrated that even for moderate number densities the probability of clustering is substantial and should not be neglected in reliability calculations. In the important special case where the random variables are failure times, models have been proposed for determining the upper bound of the hazard rate which guarantees a set of minimum failure-free operating intervals before the random failures, with a specified probability. A model has also been proposed for determining the upper bound of the hazard rate which guarantees a minimum availability target. Using the models proposed, a new strategy, models and reliability tools have been developed for setting quantitative reliability requirements which consist of determining the intersection of the hazard rate envelopes (hazard rate upper bounds) which deliver a minimum failure-free operating period before random failures, a risk of premature failure below a maximum acceptable level and a minimum required availability. It is demonstrated that setting reliability requirements solely based on an availability target does not necessarily mean a low risk of premature failure. Even at a high availability level, the probability of premature failure can be substantial. For industries characterised by a high cost of failure, the reliability requirements should involve a hazard rate envelope limiting the risk of failure below a maximum acceptable level

  6. Reliability and validity of an internet-based questionnaire measuring lifetime physical activity.

    Science.gov (United States)

    De Vera, Mary A; Ratzlaff, Charles; Doerfling, Paul; Kopec, Jacek

    2010-11-15

    Lifetime exposure to physical activity is an important construct for evaluating associations between physical activity and disease outcomes, given the long induction periods in many chronic diseases. The authors' objective in this study was to evaluate the measurement properties of the Lifetime Physical Activity Questionnaire (L-PAQ), a novel Internet-based, self-administered instrument measuring lifetime physical activity, among Canadian men and women in 2005-2006. Reliability was examined using a test-retest study. Validity was examined in a 2-part study consisting of 1) comparisons with previously validated instruments measuring similar constructs, the Lifetime Total Physical Activity Questionnaire (LT-PAQ) and the Chasan-Taber Physical Activity Questionnaire (CT-PAQ), and 2) a priori hypothesis tests of constructs measured by the L-PAQ. The L-PAQ demonstrated good reliability, with intraclass correlation coefficients ranging from 0.67 (household activity) to 0.89 (sports/recreation). Comparison between the L-PAQ and the LT-PAQ resulted in Spearman correlation coefficients ranging from 0.41 (total activity) to 0.71 (household activity); comparison between the L-PAQ and the CT-PAQ yielded coefficients of 0.58 (sports/recreation), 0.56 (household activity), and 0.50 (total activity). L-PAQ validity was further supported by observed relations between the L-PAQ and sociodemographic variables, consistent with a priori hypotheses. Overall, the L-PAQ is a useful instrument for assessing multiple domains of lifetime physical activity with acceptable reliability and validity.

  7. The Attitude Determination Scale for Value Acquisition: A Validity and Reliability Study

    Science.gov (United States)

    Cetin, Saban

    2017-01-01

    This study aims to develop a measurement tool having measurement reliability with the aim of determining attitudes for values acquisition of secondary school students. The study was conducted on totally 325 high school senior students as 200 female and 125 male students in spring semester of 2014-2015 educational year. In the study, expert opinion…

  8. The reliability of a severity rating scale to measure stuttering in an unfamiliar language.

    Science.gov (United States)

    Hoffman, Laura; Wilson, Linda; Copley, Anna; Hewat, Sally; Lim, Valerie

    2014-06-01

    With increasing multiculturalism, speech-language pathologists (SLPs) are likely to work with stuttering clients from linguistic backgrounds that differ from their own. No research to date has estimated SLPs' reliability when measuring severity of stuttering in an unfamiliar language. Therefore, this study was undertaken to estimate the reliability of SLPs' use of a 9-point severity rating (SR) scale, to measure severity of stuttering in a language that was different from their own. Twenty-six Australian SLPs rated 20 speech samples (10 Australian English [AE] and 10 Mandarin) of adults who stutter using a 9-point SR scale on two separate occasions. Judges showed poor agreement when using the scale to measure stuttering in Mandarin samples. Results also indicated that 50% of individual judges were unable to reliably measure the severity of stuttering in AE. The results highlight the need for (a) SLPs to develop intra- and inter-judge agreement when using the 9-point SR scale to measure severity of stuttering in their native language (in this case AE) and in unfamiliar languages; and (b) research into the development and evaluation of practice and/or training packages to assist SLPs to do so.

  9. The Turkish adaptation of scale to measure patient perceptions of the quality of nursing care and related hospital services: A validity and reliability study.

    Science.gov (United States)

    Oren, Besey; Zengin, Neriman; Yildiz, Nebahat

    2016-01-01

    This study aimed to test the validity and reliability of a version of the tool developed in Sri Lanka in 2011 to assess patient perceptions of the quality of nursing care and related hospital services created for use with Turkish patients. This methodological study was conducted between November 2013 and November 2014 after obtaining ethical approval and organizational permission. Data was collected during discharge from 180 adult patients who were hospitalized for at least 3 days at a medical school hospital located in Istanbul. After language validation, validity and reliability analyses of the scale were conducted. Content validity, content validity index (CVI), construct validity, and exploratory factor analysis were assessed and examined, and reliability was tested using the Cronbach's alpha coefficient and item-total correlations. Mean CVI was found to be 0.95, which is above expected value. Exploratory factor analysis revealed 4 factors with eigenvalues above 1, which explained 82.4% of total variance in the Turkish version of the tool to measure patient perceptions of nursing care and other hospital services. Factor loading for each item was ≥.40. Cronbach's alpha coefficient of sub-dimensions and total scale were found to be 0.84-0.98 and 0.98, respectively. Item-total correlations ranged from 0.56 to 0.83 for the entire group, which was above expected values. The Turkish version of the scale to assess patient perceptions of the quality of nursing care and related hospital services, which comprised 4 sub-dimensions and 36 items, was found to be valid and reliable for use with the Turkish population.

  10. Clinical assessment of dysphagia in neurodegeneration (CADN): development, validity and reliability of a bedside tool for dysphagia assessment.

    Science.gov (United States)

    Vogel, Adam P; Rommel, Natalie; Sauer, Carina; Horger, Marius; Krumm, Patrick; Himmelbach, Marc; Synofzik, Matthis

    2017-06-01

    Screening assessments for dysphagia are essential in neurodegenerative disease. Yet there are no purpose-built tools to quantify swallowing deficits at bedside or in clinical trials. A quantifiable, brief, easy to administer assessment that measures the impact of dysphagia and predicts the presence or absence of aspiration is needed. The Clinical Assessment of Dysphagia in Neurodegeneration (CADN) was designed by a multidisciplinary team (neurology, neuropsychology, speech pathology) validated against strict methodological criteria in two neurodegenerative diseases, Parkinson's disease (PD) and degenerative ataxia (DA). CADN comprises two parts, an anamnesis (part one) and consumption (part two). Two-thirds of patients were assessed using reference tests, the SWAL-QOL symptoms subscale (part one) and videofluoroscopic assessment of swallowing (part two). CADN has 11 items and can be administered and scored in an average of 7 min. Test-retest reliability was established using correlation and Bland-Altman plots. 125 patients with a neurodegenerative disease were recruited; 60 PD and 65 DA. Validity was established using ROC graphs and correlations. CADN has sensitivity of 79 and 84% and specificity 71 and 69% for parts one and two, respectively. Significant correlations with disease severity were also observed (p dysphagia symptomatology and risk of aspiration. The CADN is a reliable, valid, brief, quantifiable, and easily deployed assessment of swallowing in neurodegenerative disease. It is thus ideally suited for both clinical bedside assessment and future multicentre clinical trials in neurodegenerative disease.

  11. Relating measurement invariance, cross-level invariance, and multilevel reliability

    OpenAIRE

    Jak, S.; Jorgensen, T.D.

    2017-01-01

    Data often have a nested, multilevel structure, for example when data are collected from children in classrooms. This kind of data complicate the evaluation of reliability and measurement invariance, because several properties can be evaluated at both the individual level and the cluster level, as well as across levels. For example, cross-level invariance implies equal factor loadings across levels, which is needed to give latent variables at the two levels a similar interpretation. Reliabili...

  12. The Children's Play Therapy Instrument (CPTI). Description, development, and reliability studies.

    Science.gov (United States)

    Kernberg, P F; Chazan, S E; Normandin, L

    1998-01-01

    The Children's Play Therapy Instrument (CPTI), its development, and reliability studies are described. The CPTI is a new instrument to examine a child's play activity in individual psychotherapy. Three independent raters used the CPTI to rate eight videotaped play therapy vignettes. Results were compared with the authors' consensual scores from a preliminary study. Generally good to excellent levels of interrater reliability were obtained for the independent raters on intraclass correlation coefficients for ordinal categories of the CPTI. Likewise, kappa levels were acceptable to excellent for nominal categories of the scale. The CPTI holds promise to become a reliable measure of play activity in child psychotherapy. Further research is needed to assess discriminant validity of the CPTI for use as a diagnostic tool and as a measure of process and outcome.

  13. Contact pressure measurement in hand tool evaluation studies

    NARCIS (Netherlands)

    Kuijt-Evers, L.F.M.; Bosch, T.

    2006-01-01

    In hand tool evaluation studies, several objective measurements are used. Grip force distribution and grip force are important as they give feedback about the force which has to be performed with the hand on the handle. A measurement technique -which is related to grip force measurement- is contact

  14. Telecommunications system reliability engineering theory and practice

    CERN Document Server

    Ayers, Mark L

    2012-01-01

    "Increasing system complexity require new, more sophisticated tools for system modeling and metric calculation. Bringing the field up to date, this book provides telecommunications engineers with practical tools for analyzing, calculating, and reporting availability, reliability, and maintainability metrics. It gives the background in system reliability theory and covers in-depth applications in fiber optic networks, microwave networks, satellite networks, power systems, and facilities management. Computer programming tools for simulating the approaches presented, using the Matlab software suite, are also provided"

  15. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Directory of Open Access Journals (Sweden)

    Paschalis EI

    2014-01-01

    Full Text Available Eleftherios I Paschalis,* Fabiano Cade,* Samir Melki, Louis R Pasquale, Claes H Dohlman, Joseph B CiolinoMassachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA*These authors contributed equally to this workPurpose: To present an autonomous intraocular pressure (IOP measurement technique using a wireless implantable transducer (WIT and a motion sensor.Methods: The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline IOP.Results: On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg and mean vehicle IOP (13.27±2.1 mmHg (P=0.45, suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001, and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001. Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001. Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute, during which the IOP is not expected to change.Conclusion: IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.Keywords: IOP, pressure transducer, wireless, MEMS, implant, intraocular

  16. Validation of the Australian Midwifery Standards Assessment Tool (AMSAT): A tool to assess midwifery competence.

    Science.gov (United States)

    Sweet, Linda; Bazargan, Maryam; McKellar, Lois; Gray, Joanne; Henderson, Amanda

    2018-02-01

    There is no current validated clinical assessment tool to measure the attainment of midwifery student competence in the midwifery practice setting. The lack of a valid assessment tool has led to a proliferation of tools and inconsistency in assessment of, and feedback on student learning. This research aimed to develop and validate a tool to assess competence of midwifery students in practice-based settings. A mixed-methods approach was used and the study implemented in two phases. Phase one involved the development of the AMSAT tool with qualitative feedback from midwifery academics, midwife assessors of students, and midwifery students. In phase two the newly developed AMSAT tool was piloted across a range of midwifery practice settings and ANOVA was used to compare scores across year levels, with feedback being obtained from assessors. Analysis of 150 AMSAT forms indicate the AMSAT as: reliable (Cronbach alpha greater than 0.9); valid-data extraction loaded predominantly onto one factor; and sensitivity scores indicating level of proficiency increased across the three years. Feedback evaluation forms (n=83) suggest acceptance of this tool for the purpose of both assessing and providing feedback on midwifery student's practice performance and competence. The AMSAT is a valid, reliable and acceptable midwifery assessment tool enables consistent assessment of midwifery student competence. This assists benchmarking across midwifery education programs. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  17. The Reliability and Validity of Discrete and Continuous Measures of Psychopathology: A Quantitative Review

    Science.gov (United States)

    Markon, Kristian E.; Chmielewski, Michael; Miller, Christopher J.

    2011-01-01

    In 2 meta-analyses involving 58 studies and 59,575 participants, we quantitatively summarized the relative reliability and validity of continuous (i.e., dimensional) and discrete (i.e., categorical) measures of psychopathology. Overall, results suggest an expected 15% increase in reliability and 37% increase in validity through adoption of a…

  18. Reliability of a structured interview for admission to an emergency medicine residency program.

    Science.gov (United States)

    Blouin, Danielle

    2010-10-01

    Interviews are most important in resident selection. Structured interviews are more reliable than unstructured ones. We sought to measure the interrater reliability of a newly designed structured interview during the selection process to an Emergency Medicine residency program. The critical incident technique was used to extract the desired dimensions of performance. The interview tool consisted of 7 clinical scenarios and 1 global rating. Three trained interviewers marked each candidate on all scenarios without discussing candidates' responses. Interitem consistency and estimates of variance were computed. Twenty-eight candidates were interviewed. The generalizability coefficient was 0.67. Removing the central tendency ratings increased the coefficient to 0.74. Coefficients of interitem consistency ranged from 0.64 to 0.74. The structured interview tool provided good although suboptimal interrater reliability. Increasing the number of scenarios improves reliability as does applying differential weights to the rating scale anchors. The latter would also facilitate the identification of those candidates with extreme ratings.

  19. COMPI Fertility Problem Stress Scales is a brief, valid and reliable tool for assessing stress in patients seeking treatment

    DEFF Research Database (Denmark)

    Sobral, Maria P.; Costa, Maria E.; Schmidt, Lone

    2017-01-01

    comparability of fertility-related stress across genders and countries. STUDY DESIGN SIZE, DURATION Cross-sectional study. First, we tested the structure of the COMPI-FPSS. Then, reliability and validity (convergent and discriminant) were examined for the final model. Finally, measurement invariance both across...... genders and cultures was tested. PARTICIPANTS/MATERIALS, SETTING, METHODS Our final sample had 3923 fertility patients (1691 men and 2232 women) recruited in clinical settings from seven different countries: Denmark, China, Croatia, Germany, Greece, Hungary and Sweden. Participants had a mean age of 34......STUDY QUESTION Are the Copenhagen Multi‐Centre Psychosocial Infertility research program Fertility Problem Stress Scales (COMPI-FPSS) a reliable and valid measure across gender and culture? SUMMARY ANSWER The COMPI-FPSS is a valid and reliable measure, presenting excellent or good fit...

  20. Strength Measurements in Acute Hamstring Injuries: Intertester Reliability and Prognostic Value of Handheld Dynamometry.

    Science.gov (United States)

    Reurink, Gustaaf; Goudswaard, Gert Jan; Moen, Maarten H; Tol, Johannes L; Verhaar, Jan A N; Weir, Adam

    2016-08-01

    Study Design Cohort study, repeated measures. Background Although hamstring strength measurements are used for assessing prognosis and monitoring recovery after hamstring injury, their actual clinical relevance has not been established. Handheld dynamometry (HHD) is a commonly used method of measuring muscle strength. The reliability of HHD has not been determined in athletes with acute hamstring injuries. Objectives To determine the intertester reliability and the prognostic value of hamstring HHD strength measurement in acute hamstring injuries. Methods We measured knee flexion strength with HHD in 75 athletes at 2 visits, at baseline (within 5 days of hamstring injury) and follow-up (5 to 7 days after the baseline measurement). We assessed isometric hamstring strength in 15° and 90° of knee flexion. Reliability analysis testing was performed by 2 testers independently at the follow-up visit. We recorded the time needed to return to play (RTP) up to 6 months following baseline. Results The intraclass correlation coefficients of the strength measurements in injured hamstrings were between 0.75 and 0.83. There was a statistically significant but weak correlation between the time to RTP and the strength deficit at 15° of knee flexion measured at baseline (Spearman r = 0.25, P = .045) and at the follow-up visit (Spearman r = 0.26, P = .034). Up to 7% of the variance in time to RTP is explained by this strength deficit. None of the other strength variables were significantly correlated with time to RTP. Conclusion Hamstring strength can be reliably measured with HHD in athletes with acute hamstring injuries. The prognostic value of strength measurements is limited, as there is only a weak association between the time to RTP and hamstring strength deficit after acute injury. Level of Evidence Prognosis, level 4. J Orthop Sports Phys Ther 2016;46(8):689-696. Epub 12 May 2016. doi:10.2519/jospt.2016.6363.

  1. Reliability and Validity of the Turkish Version of the Voice-Related Quality of Life Measure.

    Science.gov (United States)

    Tezcaner, Zahide Çiler; Aksoy, Songül

    2017-03-01

    This study aims to test the validity and reliability of the Turkish version of the Voice-Related Quality of Life (V-RQOL) questionnaire. This is a nonrandomized, prospective study with control group. The questionnaire was administered to 249 individuals-130 with vocal complaint and 119 without-with a mean age of 37.8 ± 12.3 years. The Turkish version of the Voice Handicap Index (VHI) and perceptual voice evaluation measures were also administered at 2-14 days for retest reliability. The instrument was submitted to validity and reliability evaluation. The V-RQOL measure showed a strong internal consistency and test-retest reliability; the Cronbach's alpha coefficient for the overall V-RQOL was 0.969, the physical functioning domain was 0.949, and the social-emotional domain was 0.940. In the test-retest reliability test, the overall V-RQOL was found to be 0.989. The construct validity of the V-RQOL was determined based on the strength and direction of its relation to the VHI and the perceptual voice evaluation measure. The higher the VHI level, the lower the physical functioning, social-emotional, and overall score levels of the V-RQOL (r = -0.927, r = -0.912, r = -0.944, respectively; P reliability and validity and may play a crucial role in evaluating Turkish-speaking patients with voice disorders. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  2. The reliability of the Hendrich Fall Risk Model in a geriatric hospital.

    Science.gov (United States)

    Heinze, Cornelia; Halfens, Ruud; Dassen, Theo

    2008-12-01

    Aims and objectives.  The purpose of this study was to test the interrater reliability of the Hendrich Fall Risk Model, an instrument to identify patients in a hospital setting with a high risk of falling. Background.  Falls are a serious problem in older patients. Valid and reliable fall risk assessment tools are required to identify high-risk patients and to take adequate preventive measures. Methods.  Seventy older patients were independently and simultaneously assessed by six pairs of raters made up of nursing staff members. Consensus estimates were calculated using simple percentage agreement and consistency estimates using Spearman's rho and intra class coefficient. Results.  Percentage agreement ranged from 0.70 to 0.92 between the six pairs of raters. Spearman's rho coefficients were between 0.54 and 0.80 and the intra class coefficients were between 0.46 and 0.92. Conclusions.  Whereas some pairs of raters obtained considerable interobserver agreement and internal consistency, the others did not. Therefore, it is concluded that the Hendrich Fall Risk Model is not a reliable instrument. The use of more unambiguous operationalized items is preferred. Relevance to clinical practice.  In practice, well operationalized fall risk assessment tools are necessary. Observer agreement should always be investigated after introducing a standardized measurement tool. © 2008 The Authors. Journal compilation © 2008 Blackwell Publishing Ltd.

  3. Reliability of BOD POD Measurements Remains High After a Short-Duration Low-Carbohydrate Diet.

    Science.gov (United States)

    Greer, Beau Kjerulf; Edsall, Kathleen M; Greer, Anna E

    2016-04-01

    The purpose of the current study was to determine whether expected changes in body weight via a 3-day low-carbohydrate (LC) diet will disrupt the reliability of air displacement plethysmography measurements via BOD POD. Twenty-four subjects recorded their typical diets for 3 days before BOD POD and 7-site skinfold analyses. Subjects were matched for lean body mass and divided into low-CHO (LC) and control (CON) groups. The LC group was given instruction intended to prevent more than 50 grams/day of carbohydrate consumption for 3 consecutive days, and the CON group replicated their previously recorded diet. Body composition measurements were repeated after dietary intervention. Test-retest reliability measures were significant (p fat percentage in both the LC and the CON groups (rs = .993 and .965, respectively). Likewise, skinfold analysis for body fat percentage reliability was high in both groups (rs = .996 and .997, respectively). There were significant differences between 1st and 2nd BOD POD measurements for body mass (72.9 ± 13.3 vs. 72.1 ± 13.0 kg [M ± SD]) and body volume (69.0 ± 12.7-68.1 ± 12.2 L) in the LC group (p .05) in BOD POD-determined body fat percentage, lean body mass, or fat mass between the 1st and 2nd trial in either group. Body composition measures via BOD POD and 7-site skinfolds remain reliable after 3 days of an LC diet despite significant decreases in body mass.

  4. Measuring general surgery residents' communication skills from the patient's perspective using the Communication Assessment Tool (CAT).

    Science.gov (United States)

    Stausmire, Julie M; Cashen, Constance P; Myerholtz, Linda; Buderer, Nancy

    2015-01-01

    The Communication Assessment Tool (CAT) has been used and validated to assess Family and Emergency Medicine resident communication skills from the patient's perspective. However, it has not been previously reported as an outcome measure for general surgery residents. The purpose of this study is to establish initial benchmarking data for the use of the CAT as an evaluation tool in an osteopathic general surgery residency program. Results are analyzed quarterly and used by the program director to provide meaningful feedback and targeted goal setting for residents to demonstrate progressive achievement of interpersonal and communication skills with patients. The 14-item paper version of the CAT (developed by Makoul et al. for residency programs) asks patients to anonymously rate surgery residents on discrete communication skills using a 5-point rating scale immediately after the clinical encounter. Results are reported as the percentage of items rated as "excellent" (5) by the patient. The setting is a hospital-affiliated ambulatory urban surgery office staffed by the residency program. Participants are representative of adult patients of both sexes across all ages with diverse ethnic backgrounds. They include preoperative and postoperative patients, as well as those needing diagnostic testing and follow-up. Data have been collected on 17 general surgery residents from a single residency program representing 5 postgraduate year levels and 448 patient encounters since March 2012. The reliability (Cronbach α) of the tool for surgery residents was 0.98. The overall mean percentage of items rated as excellent was 70% (standard deviations = 42%), with a median of 100%. The CAT is a useful tool for measuring 1 facet of resident communication skills-the patient's perception of the physician-patient encounter. The tool provides a unique and personalized outcome measure for identifying communication strengths and improvement opportunities, allowing residents to receive

  5. FURAX: assistance tools for the qualitative and quantitative analysis of systems reliability

    International Nuclear Information System (INIS)

    Moureau, R.

    1995-01-01

    FURAX is a set of tools for the qualitative and quantitative safety analysis of systems functioning. It is particularly well adapted to the study of networks (fluids, electrical..), i.e. systems in which importance is functionally given to a flux. The analysis is based on modeling which privileges these fluxes (skeleton representation of the system for a network, functional diagram for a non single-flux system) and on the representation of components support systems. Qualitative analyses are based on the research for possible flux ways and on the technical domain knowledge. The results obtained correspond to a simplified failure mode analysis, to fault-trees relative to the events expected by the user and to minimum sections. The possible calculations on these models are: tree calculations, Markov diagram calculations of the system reliability, and probabilistic calculation of a section viewed as a tree, as a well-ordered sequence of failures, or as the absorbing state of a Markov diagram. (J.S.). 6 refs

  6. Tools for Measuring and Improving Performance.

    Science.gov (United States)

    Jurow, Susan

    1993-01-01

    Explains the need for meaningful performance measures in libraries and the Total Quality Management (TQM) approach to data collection. Five tools representing different stages of a TQM inquiry are covered (i.e., the Shewhart Cycle, flowcharts, cause-and-effect diagrams, Pareto charts, and control charts), and benchmarking is addressed. (Contains…

  7. Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program

    Science.gov (United States)

    Sled, Elizabeth A.; Sheehy, Lisa M.; Felson, David T.; Costigan, Patrick A.; Lam, Miu; Cooke, T. Derek V.

    2010-01-01

    The objective of the study was to evaluate the reliability of frontal plane lower limb alignment measures using a landmark-based method by (1) comparing inter- and intra-reader reliability between measurements of alignment obtained manually with those using a computer program, and (2) determining inter- and intra-reader reliability of computer-assisted alignment measures from full-limb radiographs. An established method for measuring alignment was used, involving selection of 10 femoral and tibial bone landmarks. 1) To compare manual and computer methods, we used digital images and matching paper copies of five alignment patterns simulating healthy and malaligned limbs drawn using AutoCAD. Seven readers were trained in each system. Paper copies were measured manually and repeat measurements were performed daily for 3 days, followed by a similar routine with the digital images using the computer. 2) To examine the reliability of computer-assisted measures from full-limb radiographs, 100 images (200 limbs) were selected as a random sample from 1,500 full-limb digital radiographs which were part of the Multicenter Osteoarthritis (MOST) Study. Three trained readers used the software program to measure alignment twice from the batch of 100 images, with two or more weeks between batch handling. Manual and computer measures of alignment showed excellent agreement (intraclass correlations [ICCs] 0.977 – 0.999 for computer analysis; 0.820 – 0.995 for manual measures). The computer program applied to full-limb radiographs produced alignment measurements with high inter- and intra-reader reliability (ICCs 0.839 – 0.998). In conclusion, alignment measures using a bone landmark-based approach and a computer program were highly reliable between multiple readers. PMID:19882339

  8. Validity and reliability of smartphone magnetometer-based goniometer evaluation of shoulder abduction--A pilot study.

    Science.gov (United States)

    Johnson, Linda B; Sumner, Sean; Duong, Tina; Yan, Posu; Bajcsy, Ruzena; Abresch, R Ted; de Bie, Evan; Han, Jay J

    2015-12-01

    Goniometers are commonly used by physical therapists to measure range-of-motion (ROM) in the musculoskeletal system. These measurements are used to assist in diagnosis and to help monitor treatment efficacy. With newly emerging technologies, smartphone-based applications are being explored for measuring joint angles and movement. This pilot study investigates the intra- and inter-rater reliability as well as concurrent validity of a newly-developed smartphone magnetometer-based goniometer (MG) application for measuring passive shoulder abduction in both sitting and supine positions, and compare against the traditional universal goniometer (UG). This is a comparative study with repeated measurement design. Three physical therapists utilized both the smartphone MG and a traditional UG to measure various angles of passive shoulder abduction in a healthy subject, whose shoulder was positioned in eight different positions with pre-determined degree of abduction while seated or supine. Each therapist was blinded to the measured angles. Concordance correlation coefficients (CCCs), Bland-Altman plotting methods, and Analysis of Variance (ANOVA) were used for statistical analyses. Both traditional UG and smartphone MG were reliable in repeated measures of standardized joint angle positions (average CCC > 0.997) with similar variability in both measurement tools (standard deviation (SD) ± 4°). Agreement between the UG and MG measurements was greater than 0.99 in all positions. Our results show that the smartphone MG has equivalent reliability compared to the traditional UG when measuring passive shoulder abduction ROM. With concordant measures and comparable reliability to the UG, the newly developed MG application shows potential as a useful tool to assess joint angles. Published by Elsevier Ltd.

  9. Screening for Psychosocial Risk in Dutch Families of a Child With Cancer: Reliability, Validity, and Usability of the Psychosocial Assessment Tool

    NARCIS (Netherlands)

    Sint Nicolaas, Simone M.; Schepers, Sasja A.; Hoogerbrugge, Peter M.; Caron, Huib N.; Kaspers, Gertjan J. L.; van den Heuvel-Eibrink, Marry M.; Grootenhuis, Martha A.; Verhaak, Chris M.

    2016-01-01

    The Psychosocial Assessment Tool (PAT) was developed to screen for psychosocial risk in families of a child diagnosed with cancer. The current study is the first describing the cross-cultural adaptation, reliability, validity, and usability of the PAT in an European country (Dutch translation).   A

  10. Reliability of a single objective measure in assessing sleepiness.

    Science.gov (United States)

    Sunwoo, Bernie Y; Jackson, Nicholas; Maislin, Greg; Gurubhagavatula, Indira; George, Charles F; Pack, Allan I

    2012-01-01

    To evaluate reliability of single objective tests in assessing sleepiness. Subjects who completed polysomnography underwent a 4-nap multiple sleep latency test (MSLT) the following day. Prior to each nap opportunity on MSLT, subjects performed the psychomotor vigilance test (PVT) and divided attention driving task (DADT). Results of single versus multiple test administrations were compared using the intraclass correlation coefficient (ICC) and adjusted for test administration order effects to explore time of day effects. Measures were explored as continuous and binary (i.e., impaired or not impaired). Community-based sample evaluated at a tertiary, university-based sleep center. 372 adult commercial vehicle operators oversampled for increased obstructive sleep apnea risk. N/A. AS CONTINUOUS MEASURES, ICC WERE AS FOLLOWS: MSLT 0.45, PVT median response time 0.69, PVT number of lapses 0.51, 10-min DADT tracking error 0.87, 20-min DADT tracking error 0.90. Based on binary outcomes, ICC were: MSLT 0.63, PVT number of lapses 0.85, 10-min DADT 0.95, 20-min DADT 0.96. Statistically significant time of day effects were seen in both the MSLT and PVT but not the DADT. Correlation between ESS and different objective tests was strongest for MSLT, range [-0.270 to -0.195] and persisted across all time points. Single DADT and PVT administrations are reliable measures of sleepiness. A single MSLT administration can reasonably discriminate individuals with MSL < 8 minutes. These results support the use of a single administration of some objective tests of sleepiness when performed under controlled conditions in routine clinical care.

  11. Inter-rater reliability of kinesthetic measurements with the KINARM robotic exoskeleton.

    Science.gov (United States)

    Semrau, Jennifer A; Herter, Troy M; Scott, Stephen H; Dukelow, Sean P

    2017-05-22

    Kinesthesia (sense of limb movement) has been extremely difficult to measure objectively, especially in individuals who have survived a stroke. The development of valid and reliable measurements for proprioception is important to developing a better understanding of proprioceptive impairments after stroke and their impact on the ability to perform daily activities. We recently developed a robotic task to evaluate kinesthetic deficits after stroke and found that the majority (~60%) of stroke survivors exhibit significant deficits in kinesthesia within the first 10 days post-stroke. Here we aim to determine the inter-rater reliability of this robotic kinesthetic matching task. Twenty-five neurologically intact control subjects and 15 individuals with first-time stroke were evaluated on a robotic kinesthetic matching task (KIN). Subjects sat in a robotic exoskeleton with their arms supported against gravity. In the KIN task, the robot moved the subjects' stroke-affected arm at a preset speed, direction and distance. As soon as subjects felt the robot begin to move their affected arm, they matched the robot movement with the unaffected arm. Subjects were tested in two sessions on the KIN task: initial session and then a second session (within an average of 18.2 ± 13.8 h of the initial session for stroke subjects), which were supervised by different technicians. The task was performed both with and without the use of vision in both sessions. We evaluated intra-class correlations of spatial and temporal parameters derived from the KIN task to determine the reliability of the robotic task. We evaluated 8 spatial and temporal parameters that quantify kinesthetic behavior. We found that the parameters exhibited moderate to high intra-class correlations between the initial and retest conditions (Range, r-value = [0.53-0.97]). The robotic KIN task exhibited good inter-rater reliability. This validates the KIN task as a reliable, objective method for quantifying

  12. Measuring functional, interactive and critical health literacy of Chinese secondary school students: reliable, valid and feasible?

    Science.gov (United States)

    Guo, Shuaijun; Davis, Elise; Yu, Xiaoming; Naccarella, Lucio; Armstrong, Rebecca; Abel, Thomas; Browne, Geoffrey; Shi, Yanqin

    2018-04-01

    Health literacy is an increasingly important topic in the global context. In mainland China, health literacy measures mainly focus on health knowledge and practices or on the functional domain for adolescents. However, little is known about interactive and critical domains. This study aimed to adopt a skills-based and three-domain (functional, interactive and critical) instrument to measure health literacy in Chinese adolescents and to examine the status and determinants of each domain. Using a systematic review, the eight-item Health Literacy Assessment Tool (HLAT-8) was selected and translated from English to Chinese (c-HLAT-8). Following the translation process, a cross-sectional study was conducted in four secondary schools in Beijing, China. A total of 650 students in Years 7-9 were recruited to complete a self-administered questionnaire that assessed socio-demographics, self-efficacy, social support, school environment, community environment and health literacy. Results showed that the c-HLAT-8 had satisfactory reliability (Cronbach's α = 0.79; intra-class correlation coefficient = 0.72) and strong validity (translation validity index (TVI) ≥0.95; χ 2 / df = 3.388, p students had an average score of 26.37 (±5.89) for the c-HLAT-8. When the determinants of each domain of health literacy were examined, social support was the strongest predictor of interactive and critical health literacy. On the contrary, self-efficacy and school environment played more dominant roles in predicting functional health literacy. The c-HLAT-8 was demonstrated to be a reliable, valid and feasible instrument for measuring functional, interactive and critical health literacy among Chinese students. The current findings indicate that increasing self-efficacy, social support and creating supportive environments are important for promoting health literacy in secondary school settings in China.

  13. Computational area measurement of orbital floor fractures: Reliability, accuracy and rapidity

    International Nuclear Information System (INIS)

    Schouman, Thomas; Courvoisier, Delphine S.; Imholz, Benoit; Van Issum, Christopher; Scolozzi, Paolo

    2012-01-01

    Objective: To evaluate the reliability, accuracy and rapidity of a specific computational method for assessing the orbital floor fracture area on a CT scan. Method: A computer assessment of the area of the fracture, as well as that of the total orbital floor, was determined on CT scans taken from ten patients. The ratio of the fracture's area to the orbital floor area was also calculated. The test–retest precision of measurement calculations was estimated using the Intraclass Correlation Coefficient (ICC) and Dahlberg's formula to assess the agreement across observers and across measures. The time needed for the complete assessment was also evaluated. Results: The Intraclass Correlation Coefficient across observers was 0.92 [0.85;0.96], and the precision of the measures across observers was 4.9%, according to Dahlberg's formula .The mean time needed to make one measurement was 2 min and 39 s (range, 1 min and 32 s to 4 min and 37 s). Conclusion: This study demonstrated that (1) the area of the orbital floor fracture can be rapidly and reliably assessed by using a specific computer system directly on CT scan images; (2) this method has the potential of being routinely used to standardize the post-traumatic evaluation of orbital fractures

  14. [Validity and reliability of the spanish EQ-5D-Y proxy version].

    Science.gov (United States)

    Gusi, N; Perez-Sousa, M A; Gozalo-Delgado, M; Olivares, P R

    2014-10-01

    A proxy version of the EQ-5D-Y, a questionnaire to evaluate the Health Related Quality of Life (HRQoL) in children and adolescents, has recently been developed. There are currently no data on the validity and reliability of this tool. The objective of this study was to analyze the validity and reliability of the EQ-5D-Y proxy version. A core set of self-report tools, including the Spanish version of the EQ-5D-Y were administered to a group of Spanish children and adolescents drawn from the general population. A similar core set of internationally standardized proxy tools, including the EQ-5D-Y proxy version were administered to their parents. Test-retest reliability was determined, and correlations with other generic measurements of HRQoL were calculated. Additionally, known group validity was examined by comparing groups with a priori expected differences in HRQoL. The agreement between the self-report and proxy version responses was also calculated. A total of 477 children and adolescents and their parents participated in the study. One week later, 158 participants completed the EQ-5D-Y/EQ-5D-Y proxy to facilitate reliability analysis. Agreement between the test-retest scores was higher than 88% for EQ-5D-Y self-report, and proxy version. Correlations with other health measurements showed similar convergent validity to that observed in the international EQ-5D-Y. Agreement between the self-report and proxy versions ranged from 72.9% to 97.1%. The results provide preliminary evidence of the reliability and validity of the EQ-5D-Y proxy version. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  15. Reliability of measuring pelvic floor elevation with a diagnostic ultrasonic imaging device

    OpenAIRE

    Ubukata, Hitomi; Maruyama, Hitoshi; Huo, Ming

    2015-01-01

    [Purpose] The purpose of this study was to investigate the reliability of measuring the amount of pelvic floor elevation during pelvic and abdominal muscle contraction with a diagnostic ultrasonic imaging device. [Subjects] The study group comprised 11 healthy women without urinary incontinence or previous birth experience. [Methods] We measured the displacement elevation of the bladder base during contraction of the abdominal and pelvic floor muscles was measured using a diagnostic ultrasoni...

  16. Load Control System Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Trudnowski, Daniel [Montana Tech of the Univ. of Montana, Butte, MT (United States)

    2015-04-03

    This report summarizes the results of the Load Control System Reliability project (DOE Award DE-FC26-06NT42750). The original grant was awarded to Montana Tech April 2006. Follow-on DOE awards and expansions to the project scope occurred August 2007, January 2009, April 2011, and April 2013. In addition to the DOE monies, the project also consisted of matching funds from the states of Montana and Wyoming. Project participants included Montana Tech; the University of Wyoming; Montana State University; NorthWestern Energy, Inc., and MSE. Research focused on two areas: real-time power-system load control methodologies; and, power-system measurement-based stability-assessment operation and control tools. The majority of effort was focused on area 2. Results from the research includes: development of fundamental power-system dynamic concepts, control schemes, and signal-processing algorithms; many papers (including two prize papers) in leading journals and conferences and leadership of IEEE activities; one patent; participation in major actual-system testing in the western North American power system; prototype power-system operation and control software installed and tested at three major North American control centers; and, the incubation of a new commercial-grade operation and control software tool. Work under this grant certainly supported the DOE-OE goals in the area of “Real Time Grid Reliability Management.”

  17. An improved model for the oPtImal Measurement Probes Allocation tool

    International Nuclear Information System (INIS)

    Sterle, C.; Neto, A.C.; De Tommasi, G.

    2015-01-01

    Highlights: • The problem of optimally allocating the probes of a diagnostic system is tackled. • The problem is decomposed in two consecutive optimization problems. • Two original ILP models are proposed and sequentially solved to optimality. • The proposed ILP models improve and extend the previous work present in literature. • Real size instances have been optimally solved with very low computation time. - Abstract: The oPtImal Measurement Probes Allocation (PIMPA) tool has been recently proposed in [1] to maximize the reliability of a tokamak diagnostic system against the failure of one or more of the processing nodes. PIMPA is based on the solution of integer linear programming (ILP) problems, and it minimizes the effect of the failure of a data acquisition component. The first formulation of the PIMPA model did not support the concept of individual slots. This work presents an improved ILP model that addresses the above mentioned problem, by taking into account all the individual probes.

  18. An improved model for the oPtImal Measurement Probes Allocation tool

    Energy Technology Data Exchange (ETDEWEB)

    Sterle, C., E-mail: claudio.sterle@unina.it [Consorzio CREATE/Dipartimento di Ingegneria Elettrica e delle Tecnologie dell’Informazione, Università degli Studi di Napoli Federico II, Via Claudio 21, 80125 Napoli (Italy); Neto, A.C. [Fusion for Energy, 08019 Barcelona (Spain); De Tommasi, G. [Consorzio CREATE/Dipartimento di Ingegneria Elettrica e delle Tecnologie dell’Informazione, Università degli Studi di Napoli Federico II, Via Claudio 21, 80125 Napoli (Italy)

    2015-10-15

    Highlights: • The problem of optimally allocating the probes of a diagnostic system is tackled. • The problem is decomposed in two consecutive optimization problems. • Two original ILP models are proposed and sequentially solved to optimality. • The proposed ILP models improve and extend the previous work present in literature. • Real size instances have been optimally solved with very low computation time. - Abstract: The oPtImal Measurement Probes Allocation (PIMPA) tool has been recently proposed in [1] to maximize the reliability of a tokamak diagnostic system against the failure of one or more of the processing nodes. PIMPA is based on the solution of integer linear programming (ILP) problems, and it minimizes the effect of the failure of a data acquisition component. The first formulation of the PIMPA model did not support the concept of individual slots. This work presents an improved ILP model that addresses the above mentioned problem, by taking into account all the individual probes.

  19. Reliability of pelvic floor measurements on three- and four-dimensional ultrasound during and after first pregnancy: implications for training.

    Science.gov (United States)

    van Veelen, G A; Schweitzer, K J; van der Vaart, C H

    2013-11-01

    To evaluate the reliability of measurements of the levator hiatus and levator-urethra gap (LUG) using three/four-dimensional (3D/4D) transperineal ultrasound in women during their first pregnancy and 6 months postpartum, and to assess the learning process for these measurements. An inexperienced observer was taught to perform measurements of the levator hiatus and LUG by an experienced observer. After training, 3D/4D ultrasound volume datasets of 40 women in the first trimester were analyzed by these two observers. Another training session then took place and both observers repeated the analyses of the same volume datasets. Finally, analyses of 40 volume datasets of the women 6 months postpartum were performed by both observers. Intra- and interobserver reliability were determined by intraclass correlation coefficients (ICC) with 95% CIs. For levator hiatal measurements, in the women during their first pregnancy the interobserver reliability was substantial to almost perfect after both the first and second training session (ICC, 0.62-0.83 and 0.71-0.89, respectively, for anteroposterior diameter, transverse diameter and area at rest, on contraction and on Valsalva) and the intraobserver reliability was substantial to almost perfect for both observers. For these measurements performed once the women had delivered, interobserver reliability was moderate to almost perfect. For LUG measurements performed during pregnancy, interobserver reliability was slight to moderate after the first training session (ICC, 0.14-0.54), but improved after the second training session (ICC, 0.38-0.71), and intraobserver reliability was moderate to substantial for the experienced observer and slight to moderate for the inexperienced observer. For these measurements performed when the women had delivered, interobserver reliability was fair to moderate. The levator hiatus and LUG can be measured reliably using 3D/4D ultrasound in primigravid and primiparous women. The technique to measure

  20. Is Google Trends a reliable tool for digital epidemiology? Insights from different clinical settings.

    Science.gov (United States)

    Cervellin, Gianfranco; Comelli, Ivan; Lippi, Giuseppe

    2017-09-01

    Internet-derived information has been recently recognized as a valuable tool for epidemiological investigation. Google Trends, a Google Inc. portal, generates data on geographical and temporal patterns according to specified keywords. The aim of this study was to compare the reliability of Google Trends in different clinical settings, for both common diseases with lower media coverage, and for less common diseases attracting major media coverage. We carried out a search in Google Trends using the keywords "renal colic", "epistaxis", and "mushroom poisoning", selected on the basis of available and reliable epidemiological data. Besides this search, we carried out a second search for three clinical conditions (i.e., "meningitis", "Legionella Pneumophila pneumonia", and "Ebola fever"), which recently received major focus by the Italian media. In our analysis, no correlation was found between data captured from Google Trends and epidemiology of renal colics, epistaxis and mushroom poisoning. Only when searching for the term "mushroom" alone the Google Trends search generated a seasonal pattern which almost overlaps with the epidemiological profile, but this was probably mostly due to searches for harvesting and cooking rather than to for poisoning. The Google Trends data also failed to reflect the geographical and temporary patterns of disease for meningitis, Legionella Pneumophila pneumonia and Ebola fever. The results of our study confirm that Google Trends has modest reliability for defining the epidemiology of relatively common diseases with minor media coverage, or relatively rare diseases with higher audience. Overall, Google Trends seems to be more influenced by the media clamor than by true epidemiological burden. Copyright © 2017 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.

  1. Reliability measures for indexed semi-Markov chains applied to wind energy production

    International Nuclear Information System (INIS)

    D'Amico, Guglielmo; Petroni, Filippo; Prattico, Flavio

    2015-01-01

    The computation of the dependability measures is a crucial point in many engineering problems as well as in the planning and development of a wind farm. In this paper we address the issue of energy production by wind turbines by using an indexed semi-Markov chain as a model of wind speed. We present the mathematical model, the data and technical characteristics of a commercial wind turbine (Aircon HAWT-10kW). We show how to compute some of the main dependability measures such as reliability, availability and maintainability functions. We compare the results of the model with real energy production obtained from data available in the Lastem station (Italy) and sampled every 10 min. - Highlights: • Semi-Markov models. • Time series generation of wind speed. • Computation of availability, reliability and maintainability.

  2. Cyber Physical Systems for User Reliability Measurements in a Sharing Economy Environment.

    Science.gov (United States)

    Seo, Aria; Jeong, Junho; Kim, Yeichang

    2017-08-13

    As the sharing economic market grows, the number of users is also increasing but many problems arise in terms of reliability between providers and users in the processing of services. The existing methods provide shared economic systems that judge the reliability of the provider from the viewpoint of the user. In this paper, we have developed a system for establishing mutual trust between providers and users in a shared economic environment to solve existing problems. In order to implement a system that can measure and control users' situation in a shared economic environment, we analyzed the necessary factors in a cyber physical system (CPS). In addition, a user measurement system based on a CPS structure in a sharing economic environment is implemented through analysis of the factors to consider when constructing a CPS.

  3. Development of a tool to measure person-centered maternity care in developing settings: validation in a rural and urban Kenyan population.

    Science.gov (United States)

    Afulani, Patience A; Diamond-Smith, Nadia; Golub, Ginger; Sudhinaraset, May

    2017-09-22

    Person-centered reproductive health care is recognized as critical to improving reproductive health outcomes. Yet, little research exists on how to operationalize it. We extend the literature in this area by developing and validating a tool to measure person-centered maternity care. We describe the process of developing the tool and present the results of psychometric analyses to assess its validity and reliability in a rural and urban setting in Kenya. We followed standard procedures for scale development. First, we reviewed the literature to define our construct and identify domains, and developed items to measure each domain. Next, we conducted expert reviews to assess content validity; and cognitive interviews with potential respondents to assess clarity, appropriateness, and relevance of the questions. The questions were then refined and administered in surveys; and survey results used to assess construct and criterion validity and reliability. The exploratory factor analysis yielded one dominant factor in both the rural and urban settings. Three factors with eigenvalues greater than one were identified for the rural sample and four factors identified for the urban sample. Thirty of the 38 items administered in the survey were retained based on the factors loadings and correlation between the items. Twenty-five items load very well onto a single factor in both the rural and urban sample, with five items loading well in either the rural or urban sample, but not in both samples. These 30 items also load on three sub-scales that we created to measure dignified and respectful care, communication and autonomy, and supportive care. The Chronbach alpha for the main scale is greater than 0.8 in both samples, and that for the sub-scales are between 0.6 and 0.8. The main scale and sub-scales are correlated with global measures of satisfaction with maternity services, suggesting criterion validity. We present a 30-item scale with three sub-scales to measure person

  4. Pneumothorax size measurements on digital chest radiographs: Intra- and inter- rater reliability.

    Science.gov (United States)

    Thelle, Andreas; Gjerdevik, Miriam; Grydeland, Thomas; Skorge, Trude D; Wentzel-Larsen, Tore; Bakke, Per S

    2015-10-01

    Detailed and reliable methods may be important for discussions on the importance of pneumothorax size in clinical decision-making. Rhea's method is widely used to estimate pneumothorax size in percent based on chest X-rays (CXRs) from three measure points. Choi's addendum is used for anterioposterior projections. The aim of this study was to examine the intrarater and interrater reliability of the Rhea and Choi method using digital CXR in the ward based PACS monitors. Three physicians examined a retrospective series of 80 digital CXRs showing pneumothorax, using Rhea and Choi's method, then repeated in a random order two weeks later. We used the analysis of variance technique by Eliasziw et al. to assess the intrarater and interrater reliability in altogether 480 estimations of pneumothorax size. Estimated pneumothorax sizes ranged between 5% and 100%. The intrarater reliability coefficient was 0.98 (95% one-sided lower-limit confidence interval C 0.96), and the interrater reliability coefficient was 0.95 (95% one-sided lower-limit confidence interval 0.93). This study has shown that the Rhea and Choi method for calculating pneumothorax size has high intrarater and interrater reliability. These results are valid across gender, side of pneumothorax and whether the patient is diagnosed with primary or secondary pneumothorax. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Systematic review of measurement tools to assess surgeons' intraoperative cognitive workload.

    Science.gov (United States)

    Dias, R D; Ngo-Howard, M C; Boskovski, M T; Zenati, M A; Yule, S J

    2018-04-01

    Surgeons in the operating theatre deal constantly with high-demand tasks that require simultaneous processing of a large amount of information. In certain situations, high cognitive load occurs, which may impact negatively on a surgeon's performance. This systematic review aims to provide a comprehensive understanding of the different methods used to assess surgeons' cognitive load, and a critique of the reliability and validity of current assessment metrics. A search strategy encompassing MEDLINE, Embase, Web of Science, PsycINFO, ACM Digital Library, IEEE Xplore, PROSPERO and the Cochrane database was developed to identify peer-reviewed articles published from inception to November 2016. Quality was assessed by using the Medical Education Research Study Quality Instrument (MERSQI). A summary table was created to describe study design, setting, specialty, participants, cognitive load measures and MERSQI score. Of 391 articles retrieved, 84 met the inclusion criteria, totalling 2053 unique participants. Most studies were carried out in a simulated setting (59 studies, 70 per cent). Sixty studies (71 per cent) used self-reporting methods, of which the NASA Task Load Index (NASA-TLX) was the most commonly applied tool (44 studies, 52 per cent). Heart rate variability analysis was the most used real-time method (11 studies, 13 per cent). Self-report instruments are valuable when the aim is to assess the overall cognitive load in different surgical procedures and assess learning curves within competence-based surgical education. When the aim is to assess cognitive load related to specific operative stages, real-time tools should be used, as they allow capture of cognitive load fluctuation. A combination of both subjective and objective methods might provide optimal measurement of surgeons' cognition. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.

  6. The concurrent validity and reliability of the Leg Motion system for measuring ankle dorsiflexion range of motion in older adults

    Directory of Open Access Journals (Sweden)

    Carlos Romero Morales

    2017-01-01

    .50° ± 5.54 and inclinometer app (right 46.53° ± 4.79; left 45.27° ± 5.19. The paired t-test showed no significant differences between the limbs or between the test and re-test values. The test re-test reliability results for Leg Motion were as follows: the standard error of the measurement ranged from 0.29 to 0.43 cm, the minimal detectable difference ranged from 0.79 to 1.19 cm, and the intraclass correlation coefficients (ICC values ranged from 0.97 to 0.98. Conclusions The results of the present study indicated that the Leg Motion device is a valid, reliable, accessible and portable tool as an alternative to the classic weight-bearing lunge test for measuring ankle dorsiflexion ROM in older adults.

  7. Evaluating test-retest reliability in patient-reported outcome measures for older people: A systematic review.

    Science.gov (United States)

    Park, Myung Sook; Kang, Kyung Ja; Jang, Sun Joo; Lee, Joo Yun; Chang, Sun Ju

    2018-03-01

    This study aimed to evaluate the components of test-retest reliability including time interval, sample size, and statistical methods used in patient-reported outcome measures in older people and to provide suggestions on the methodology for calculating test-retest reliability for patient-reported outcomes in older people. This was a systematic literature review. MEDLINE, Embase, CINAHL, and PsycINFO were searched from January 1, 2000 to August 10, 2017 by an information specialist. This systematic review was guided by both the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist and the guideline for systematic review published by the National Evidence-based Healthcare Collaborating Agency in Korea. The methodological quality was assessed by the Consensus-based Standards for the selection of health Measurement Instruments checklist box B. Ninety-five out of 12,641 studies were selected for the analysis. The median time interval for test-retest reliability was 14days, and the ratio of sample size for test-retest reliability to the number of items in each measure ranged from 1:1 to 1:4. The most frequently used statistical methods for continuous scores was intraclass correlation coefficients (ICCs). Among the 63 studies that used ICCs, 21 studies presented models for ICC calculations and 30 studies reported 95% confidence intervals of the ICCs. Additional analyses using 17 studies that reported a strong ICC (>0.09) showed that the mean time interval was 12.88days and the mean ratio of the number of items to sample size was 1:5.37. When researchers plan to assess the test-retest reliability of patient-reported outcome measures for older people, they need to consider an adequate time interval of approximately 13days and the sample size of about 5 times the number of items. Particularly, statistical methods should not only be selected based on the types of scores of the patient-reported outcome measures, but should also be described clearly in

  8. Measuring Certified Registered Nurse Anesthetist Organizational Climate: Instrument Adaptation.

    Science.gov (United States)

    Boyd, Donald; Poghosyan, Lusine

    2017-08-01

    No tool exists measuring certified registered nurse anesthetist (CRNA) organizational climate. The study's purpose is to adapt a validated tool to measure CRNA organizational climate. Content validity of the Certified Registered Nurse Anesthetist Organizational Climate Questionnaire (CRNA-OCQ) was established. Pilot testing was conducted to determine internal reliability consistency of the subscales. Experts rated the tool as content valid. The subscales had high internal consistency reliability (with respective Cronbach's alphas): CRNA-Anesthesiologist Relations (.753), CRNA-Physician Relations (.833), CRNA-Administration Relations (.895), Independent Practice (.830), Support for CRNA Practice (.683), and Professional Visibility (.772). Further refinement of the CRNA-OCQ is necessary. Measurement and assessment of CRNA organizational climate may produce evidence needed to improve provider and patient outcomes.

  9. Smartphone Photography as a Tool to Measure Knee Range of Motion.

    Science.gov (United States)

    Mica, Megan Conti; Wagner, Eric R; Shin, Alexander Y

    2018-01-01

    The objective of this study was to validate measuring knee range of motion (ROM) from smartphone photography. Thirty-two participants (64 knees) obtained smartphone photographs of knee flexion and extension. Surgeons obtained the same photographs and goniometric measurement of ROM. ROM was measured using Adobe Photoshop. Goniometer versus digital measurements, participant versus surgeon photographs, and interobserver measurements were analyzed. The average difference in goniometer and digital photograph measurements was 5°. The interclass correlation was .642(L) and .656(R). The Bland-Altman plots demonstrated that 29/32 digital measurements were within the 95% confidence interval (CI). Participants' versus researchers' photographs averaged a 2° difference. The interclass correlation was .924(L) and .91(R). Bland-Altman plots demonstrated that 31/32 measurements were within the 95% CI. Interobserver reliability averaged aROMdifference of 5°. The concordance coefficients were .647(L) and .723(R). Bland-Altman plots demonstrated that 30 of 32 digital measurements were within the 95% CI. Measuring knee ROM using smartphone digital photography is valid and reliable. (Journal of Surgical Orthopaedic Advances 27(1):52-57, 2018).

  10. Reliability and Validity of Computerized Force Platform Measures of Balance Function in Healthy Older Adults.

    Science.gov (United States)

    Harro, Cathy C; Garascia, Chelsea

    2018-01-10

    Postural control declines with aging and is an independent risk factor for falls in older adults. Objective examination of balance function is warranted to direct fall prevention strategies. Force platform (FP) systems provide quantitative measures of postural control and analysis of different aspects of balance. The purpose of this study was to examine the reliability and validity of FP measures in healthy older adults. This study enrolled 46 healthy elderly adults, mean age 67.67 (5.1) years, who had no history of falls. They were assessed on 3 standardized tests on the NeuroCom Equitest FP system: limits of stability (LOS), motor control test (MCT), and sensory organization test (SOT). The test battery was administered twice within a 10-day period for test-retest reliability; intraclass correlation coefficients (ICCs), standard error of measurement (SEM), and minimal detectable change based on a 95% confidence interval (MDC95) were calculated. FP measures were compared with criterion clinical balance (Mini-BESTest and Functional Gait Assessment) and gait (10-m walk and 6-minute walk) measures to examine concurrent validity using Pearson correlation coefficients. Multiple linear regression analysis examined whether age and activity level were associated with FP performance. The α level was set at P point excursion measures all demonstrated excellent test-retest reliability (ICC = 0.90, 0.85, and 0.77, respectively), whereas moderate to good reliability was found for SOT vestibular ratio score (ICC = 0.71). There was large variability in performance in this healthy elderly cohort, resulting in relatively large MDC95 for these measures, especially for the LOS test. Fair correlations were found between LOS end point excursion and clinical balance and gait measures (r = 0.31-0.49), and between MCT average latency and gait measures only (r = -0.32). No correlations were found between SOT measures and clinical balance and gait measures. Age was only marginally

  11. RTE - Reliability report 2016

    International Nuclear Information System (INIS)

    2017-06-01

    (AMELIE, Ampacite, iTesla, APOGEE, etc.) designed to predict constraints on the future power system and develop new tools to tackle them. And the Winter Packet, unveiled by the European Commission at the end of 2016, which features numerous provisions designed to increase the reliability of the power system and which has a bearing on the role played by transmission system operators. RTE will ensure that it sheds light on the political issues which underlie the technical provisions put forward and that appropriate measures are adopted for reaching the objectives associated with the energy transition

  12. Measuring couple relationship quality in a rural African population: Validation of a Couple Functionality Assessment Tool in Malawi.

    Directory of Open Access Journals (Sweden)

    Allison Ruark

    Full Text Available Available data suggest that individual and family well-being are linked to the quality of women's and men's couple relationships, but few tools exist to assess couple relationship functioning in low- and middle-income countries. In response to this gap, Catholic Relief Services has developed a Couple Functionality Assessment Tool (CFAT to capture valid and reliable data on various domains of relationship quality. This tool is designed to be used by interventions which aim to improve couple and family well-being as a means of measuring the effectiveness of these interventions, particularly related to couple relationship quality. We carried out a validation study of the CFAT among 401 married and cohabiting adults (203 women and 198 men in rural Chikhwawa District, Malawi. Using psychometric scales, the CFAT addressed six domains of couple relationship quality (intimacy, partner support, sexual satisfaction, gender roles, decision-making, and communication and conflict management, and included questions on intimate partner violence. We used exploratory factor analysis to assess scale performance of each domain and produce a shortened Relationship Quality Index (RQI composed of items from five relationship quality domains. This article reports the performance of the RQI. Internal reliability and validity of the RQI were found to be good. Regression analyses examined the relationship of the RQI to outcomes important to health and development: intra-household cooperation, positive health behaviors, intimate partner violence, and gender-equitable norms. We found many significant correlations between RQI scores and these couple- and family-level development issues. There is a need to further validate the tool with use in other populations as well as to continue to explore whether the observed linkages between couple functionality and development outcomes are causal relationships.

  13. Study on highly reliable digital communication technology of reactor nuclear measuring equipment

    International Nuclear Information System (INIS)

    Gu Pengfei; Huang Xiaojin

    2007-01-01

    To meet the need of highly reliable of reactor nuclear measuring equipment, in allusion to the idiographic request of nuclear measuring equipment, the actual technical development and the application in industrial field, we design a kind of redundancy communication net based on PROFIBUS, and a kind of communication interface module based on redundancy PROFIBUS communication, which link the nuclear measuring equipment and PROFIBUS communication net, and also lay a foundation for advanced research. (authors)

  14. Reliability and validity in measurement of true humeral retroversion by a three-dimensional cylinder fitting method.

    Science.gov (United States)

    Saka, Masayuki; Yamauchi, Hiroki; Hoshi, Kenji; Yoshioka, Toru; Hamada, Hidetoshi; Gamada, Kazuyoshi

    2015-05-01

    Humeral retroversion is defined as the orientation of the humeral head relative to the distal humerus. Because none of the previous methods used to measure humeral retroversion strictly follow this definition, values obtained by these techniques vary and may be biased by morphologic variations of the humerus. The purpose of this study was 2-fold: to validate a method to define the axis of the distal humerus with a virtual cylinder and to establish the reliability of 3-dimensional (3D) measurement of humeral retroversion by this cylinder fitting method. Humeral retroversion in 14 baseball players (28 humeri) was measured by the 3D cylinder fitting method. The root mean square error was calculated to compare values obtained by a single tester and by 2 different testers using the embedded coordinate system. To establish the reliability, intraclass correlation coefficient (ICC) and precision (standard error of measurement [SEM]) were calculated. The root mean square errors for the humeral coordinate system were reliability and precision of the 3D measurement of retroversion yielded an intratester ICC of 0.99 (SEM, 1.0°) and intertester ICC of 0.96 (SEM, 2.8°). The error in measurements obtained by a distal humerus cylinder fitting method was small enough not to affect retroversion measurement. The 3D measurement of retroversion by this method provides excellent intratester and intertester reliability. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  15. Reliability and reference values of two clinical measurements of dynamic and static knee position in healthy children

    DEFF Research Database (Denmark)

    Ortqvist, Maria; Moström, Eva B; Roos, Ewa M.

    2011-01-01

    PURPOSE: The purposes of this study were to evaluate reliability of the Single-limb mini squat test (a dynamic measure of medio-lateral knee position) and the Quadriceps-angle (Q-angle) (a static measure of medio-lateral knee position), present paediatric reference values of the Q......-angle measurements was found. Reference values for the Q-angle (mean 13.5° (1.9)-15.3° (2.8)) varies with age and gender. No associations were found between dynamic and static measures. CONCLUSIONS: The Single-limb mini squat test showed a moderate reliability and the Q-angle showed a fair to moderate reliability......-angle, and evaluate the association between the tests. METHODS: Two hundred and forty-six healthy children (9-16 years) were included (intra/inter-rater reliability for Q-angle (n = 37/85) and for Single-limb mini squat test (n = 33/28)). Dynamic medio-lateral knee position was assessed by the Single-limb mini squat...

  16. Balance Assessment in Sports-Related Concussion: Evaluating Test-Retest Reliability of the Equilibrate System.

    Science.gov (United States)

    Odom, Mitchell J; Lee, Young M; Zuckerman, Scott L; Apple, Rachel P; Germanos, Theodore; Solomon, Gary S; Sills, Allen K

    2016-01-01

    This study evaluated the test-retest reliability of a novel computer-based, portable balance assessment tool, the Equilibrate System (ES), used to diagnose sports-related concussion. Twenty-seven students participated in ES testing consisting of three sessions over 4 weeks. The modified Balance Error Scoring System was performed. For each participant, test-retest reliability was established using the intraclass correlation coefficient (ICC). The ES test-retest reliability from baseline to week 2 produced an ICC value of 0.495 (95% CI, 0.123-0.745). Week 2 testing produced ICC values of 0.602 (95% CI, 0.279-0.803) and 0.610 (95% CI, 0.299-0.804), respectively. All other single measures test-retest reliability values produced poor ICC values. Same-day ES testing showed fair to good test-retest reliability while interweek measures displayed poor to fair test-retest reliability. Testing conditions should be controlled when using computerized balance assessment methods. ES testing should only be used as a part of a comprehensive assessment.

  17. Test-retest and interrater reliability of the functional lower extremity evaluation.

    Science.gov (United States)

    Haitz, Karyn; Shultz, Rebecca; Hodgins, Melissa; Matheson, Gordon O

    2014-12-01

    Repeated-measures clinical measurement reliability study. To establish the reliability and face validity of the Functional Lower Extremity Evaluation (FLEE). The FLEE is a 45-minute battery of 8 standardized functional performance tests that measures 3 components of lower extremity function: control, power, and endurance. The reliability and normative values for the FLEE in healthy athletes are unknown. A face validity survey for the FLEE was sent to sports medicine personnel to evaluate the level of importance and frequency of clinical usage of each test included in the FLEE. The FLEE was then administered and rated for 40 uninjured athletes. To assess test-retest reliability, each athlete was tested twice, 1 week apart, by the same rater. To assess interrater reliability, 3 raters scored each athlete during 1 of the testing sessions. Intraclass correlation coefficients were used to assess the test-retest and interrater reliability of each of the FLEE tests. In the face validity survey, the FLEE tests were rated as highly important by 58% to 71% of respondents but frequently used by only 26% to 45% of respondents. Interrater reliability intraclass correlation coefficients ranged from 0.83 to 1.00, and test-retest reliability ranged from 0.71 to 0.95. The FLEE tests are considered clinically important for assessing lower extremity function by sports medicine personnel but are underused. The FLEE also is a reliable assessment tool. Future studies are required to determine if use of the FLEE to make return-to-play decisions may reduce reinjury rates.

  18. Reliability of widefield capillary microscopy to measure nailfold capillary density in systemic sclerosis.

    Science.gov (United States)

    Hudson, M; Masetto, A; Steele, R; Arthurs, E; Baron, M

    2010-01-01

    To determine intra- and inter-observer reliability of widefield microscopy to measure nailfold capillary density in patients with systemic sclerosis (SSc). Five SSc patients were examined with a STEMV-8 Zeiss biomicroscope with 50x magnification. The nailfold of the second, third, fourth and fifth fingers of both hands of each patient were photographed twice by each of two observers, once in the morning and again in the afternoon (total of 32 pictures). Two raters reviewed the photographs to produce capillary density readings. Intra- and inter-rater reliability of the readings were computed using intra-class correlations (ICC). Additional analyses were undertaken to determine the impact of other sources of variability in the data, namely patient, finger, technician and time. Intra-and inter-rater reliability were substantial (ICC 0.72-0.84) when raters were reading the same photographs or photographs taken at the same time of day. Agreement was only fair between morning and afternoon density readings (ICC 0.30-0.37). Patients, individual fingers and technician accounted for a large part of the variability in the data (combined variance component of 7.69 out of the total 12.23). The coefficient of variation of widefield microscopy was 24%. Although intra- and inter-rater reliability of nailfold capillary density measurements using widefield microscopy are good, proper standardisation of the conditions under which capillaroscopy is done and better imaging of nailfold capillary abnormalities should be considered if nailfold capillary density is to be used as an outcome measure in multi-centre clinical trials in SSc.

  19. Validity and reliability of an in-training evaluation report to measure the CanMEDS roles in emergency medicine residents.

    Science.gov (United States)

    Kassam, Aliya; Donnon, Tyrone; Rigby, Ian

    2014-03-01

    There is a question of whether a single assessment tool can assess the key competencies of residents as mandated by the Royal College of Physicians and Surgeons of Canada CanMEDS roles framework. The objective of the present study was to investigate the reliability and validity of an emergency medicine (EM) in-training evaluation report (ITER). ITER data from 2009 to 2011 were combined for residents across the 5 years of the EM residency training program. An exploratory factor analysis with varimax rotation was used to explore the construct validity of the ITER. A total of 172 ITERs were completed on residents across their first to fifth year of training. A combined, 24-item ITER yielded a five-factor solution measuring the CanMEDs role Medical Expert/Scholar, Communicator/Collaborator, Professional, Health Advocate and Manager subscales. The factor solution accounted for 79% of the variance, and reliability coefficients (Cronbach alpha) ranged from α  =  0.90 to 0.95 for each subscale and α  =  0.97 overall. The combined, 24-item ITER used to assess residents' competencies in the EM residency program showed strong reliability and evidence of construct validity for assessment of the CanMEDS roles. Further research is needed to develop and test ITER items that will differentiate each CanMEDS role exclusively.

  20. Reliability and maintainability

    International Nuclear Information System (INIS)

    1994-01-01

    Several communications in this conference are concerned with nuclear plant reliability and maintainability; their titles are: maintenance optimization of stand-by Diesels of 900 MW nuclear power plants; CLAIRE: an event-based simulation tool for software testing; reliability as one important issue within the periodic safety review of nuclear power plants; design of nuclear building ventilation by the means of functional analysis; operation characteristic analysis for a power industry plant park, as a function of influence parameters

  1. Carrier-interleaved orthogonal multi-electrode multi-carrier resistivity-measurement tool

    International Nuclear Information System (INIS)

    Cai, Yu; Sha, Shuang

    2016-01-01

    This paper proposes a new carrier-interleaved orthogonal multi-electrode multi-carrier resistivity-measurement tool used in a cylindrical borehole environment during oil-based mud drilling processes. The new tool is an orthogonal frequency division multiplexing access-based contactless multi-measurand detection tool. The tool can measure formation resistivity in different azimuthal angles and elevational depths. It can measure many more measurands simultaneously in a specified bandwidth than the legacy frequency division multiplexing multi-measurand tool without a channel-select filter while avoiding inter-carrier interference. The paper also shows that formation resistivity is not sensitive to frequency in certain frequency bands. The average resistivity collected from N subcarriers can increase the measurement of the signal-to-noise ratio (SNR) by N times given no amplitude clipping in the current-injection electrode. If the clipping limit is taken into account, with the phase rotation of each single carrier, the amplitude peak-to-average ratio can be reduced by 3 times, and the SNR can achieve a 9/ N times gain over the single-carrier system. The carrier-interleaving technique is also introduced to counter the carrier frequency offset (CFO) effect, where the CFO will cause inter-pad interference. A qualitative analysis and simulations demonstrate that block-interleaving performs better than tone-interleaving when coping with a large CFO. The theoretical analysis also suggests that increasing the subcarrier number can increase the measurement speed or enhance elevational resolution without sacrificing receiver performance. The complex orthogonal multi-pad multi-carrier resistivity logging tool, in which all subcarriers are complex signals, can provide a larger available subcarrier pool than other types of transceivers. (paper)

  2. A Systematic Review of Statistical Methods Used to Test for Reliability of Medical Instruments Measuring Continuous Variables

    Directory of Open Access Journals (Sweden)

    Rafdzah Zaki

    2013-06-01

    Full Text Available   Objective(s: Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice.   Materials and Methods: In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. Results: The Intra-class Correlation Coefficient (ICC is the most popular method with 25 (60% studies having used this method followed by the comparing means (8 or 19%. Out of 25 studies using the ICC, only 7 (28% reported the confidence intervals and types of ICC used. Most studies (71% also tested the agreement of instruments. Conclusion: This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  3. Social Media Addiction Scale-Student Form: The Reliability and Validity Study

    Science.gov (United States)

    Sahin, Cengiz

    2018-01-01

    The purpose of this study is to develop a valid and reliable measurement tool to determine the social media addictions of secondary school, high school and university students. 998 students participated in the study. 476 students from secondary schools, high schools and universities participated in the first application during which the…

  4. Determining Reliability and Validity of the Persian Version of Software Usability Measurements Inventory (SUMI) Questionnaire

    OpenAIRE

    seyed abolfazl zakerian; Roya Azizi; Mehdi Rahgozar

    2013-01-01

    The term usability refers to a special index for success of an operating system. This study aimed to determine the reliability and validity of the Software Usability Measurements Inventory (SUMI) questionnaire as one of the valid and common questionnaires about usability evaluation. The back translation method was used to translate the questionnaire from English to Persian back to English. Moreover, repeatability or test-retest reliability was practically used to determine the reliability of ...

  5. Reliability and Validity Assessment of a Linear Position Transducer

    Directory of Open Access Journals (Sweden)

    Manuel V. Garnacho-Castaño

    2015-03-01

    Full Text Available The objectives of the study were to determine the validity and reliability of peak velocity (PV, average velocity (AV, peak power (PP and average power (AP measurements were made using a linear position transducer. Validity was assessed by comparing measurements simultaneously obtained using the Tendo Weightlifting Analyzer Systemi and T-Force Dynamic Measurement Systemr (Ergotech, Murcia, Spain during two resistance exercises, bench press (BP and full back squat (BS, performed by 71 trained male subjects. For the reliability study, a further 32 men completed both lifts using the Tendo Weightlifting Analyzer Systemz in two identical testing sessions one week apart (session 1 vs. session 2. Intraclass correlation coefficients (ICCs indicating the validity of the Tendo Weightlifting Analyzer Systemi were high, with values ranging from 0.853 to 0.989. Systematic biases and random errors were low to moderate for almost all variables, being higher in the case of PP (bias ±157.56 W; error ±131.84 W. Proportional biases were identified for almost all variables. Test-retest reliability was strong with ICCs ranging from 0.922 to 0.988. Reliability results also showed minimal systematic biases and random errors, which were only significant for PP (bias -19.19 W; error ±67.57 W. Only PV recorded in the BS showed no significant proportional bias. The Tendo Weightlifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and estimating power in resistance exercises. The low biases and random errors observed here (mainly AV, AP make this device a useful tool for monitoring resistance training.

  6. The Mayo Dysphagia Questionnaire-30: documentation of reliability and validity of a tool for interventional trials in adults with esophageal disease.

    Science.gov (United States)

    McElhiney, Judith; Lohse, Matthew R; Arora, Amindra S; Peloquin, Joanna M; Geno, Debra M; Kuntz, Melissa M; Enders, Felicity B; Fredericksen, Mary; Abdalla, Adil A; Khan, Yulia; Talley, Nicholas J; Diehl, Nancy N; Beebe, Timothy J; Harris, Ann M; Farrugia, Gianrico; Graner, Darlene E; Murray, Joseph A; Locke, G Richard; Grothe, Rayna M; Crowell, Michael D; Francis, Dawn L; Grudell, April M B; Dabade, Tushar; Ramirez, Angelica; Alkhatib, MhdMaan; Alexander, Jeffrey A; Kimber, Jessica; Prasad, Ganapathy; Zinsmeister, Alan R; Romero, Yvonne

    2010-09-01

    The aim of this study was to develop the Mayo Dysphagia Questionnaire-30 Day (MDQ-30), a tool to measure esophageal dysphagia, by adapting items from validated instruments for use in clinical trials, and assess its feasibility, reproducibility, and concurrent validity. Outpatients referred to endoscopy for dysphagia or seen in a specialty clinic were recruited. Feasibility testing was done to identify problematic items. Reproducibility was measured by test-retest format. Concurrent validity reflects agreement between information gathered in a structured interview versus the patients' written responses. The MDQ-30, a 28-item instrument, took 10 min (range = 5-30 min) to complete. Four hundred thirty-one outpatients [210 (49%) men; mean age = 61 years] participated. Overall, most concurrent validity kappa values for dysphagia were very good to excellent with a median of 0.78 (min 0.28, max 0.95). The majority of reproducibility kappa values for dysphagia were moderate to excellent with a median kappa value of 0.66 (min 0.07, max 1.0). Overall, concurrent validity and reproducibility kappa values for gastroesophageal reflux disease (GERD) symptoms were 0.81 (95% CI = 0.72, 0.91) and 0.66 (95% CI = 0.55, 0.77), respectively. Individual item percent agreement was generally very good to excellent. Internal consistency was excellent. We conclude that the MDQ-30 is an easy-to-complete tool to evaluate reliably dysphagia symptoms over the last 30 days.

  7. Failure database and tools for wind turbine availability and reliability analyses. The application of reliability data for selected wind turbines

    DEFF Research Database (Denmark)

    Kozine, Igor; Christensen, P.; Winther-Jensen, M.

    2000-01-01

    The objective of this project was to develop and establish a database for collecting reliability and reliability-related data, for assessing the reliability of wind turbine components and subsystems and wind turbines as a whole, as well as for assessingwind turbine availability while ranking the ...... similar safety systems. The database was established with Microsoft Access DatabaseManagement System, the software for reliability and availability assessments was created with Visual Basic....... the contributions at both the component and system levels. The project resulted in a software package combining a failure database with programs for predicting WTB availability and the reliability of all thecomponents and systems, especially the safety system. The report consists of a description of the theoretical......The objective of this project was to develop and establish a database for collecting reliability and reliability-related data, for assessing the reliability of wind turbine components and subsystems and wind turbines as a whole, as well as for assessingwind turbine availability while ranking...

  8. Development and evaluation of the British English coordinate response measure speech-in-noise test as an occupational hearing assessment tool.

    Science.gov (United States)

    Semeraro, Hannah D; Rowan, Daniel; van Besouw, Rachel M; Allsopp, Adrian A

    2017-10-01

    The studies described in this article outline the design and development of a British English version of the coordinate response measure (CRM) speech-in-noise (SiN) test. Our interest in the CRM is as a SiN test with high face validity for occupational auditory fitness for duty (AFFD) assessment. Study 1 used the method of constant stimuli to measure and adjust the psychometric functions of each target word, producing a speech corpus with equal intelligibility. After ensuring all the target words had similar intelligibility, for Studies 2 and 3, the CRM was presented in an adaptive procedure in stationary speech-spectrum noise to measure speech reception thresholds and evaluate the test-retest reliability of the CRM SiN test. Studies 1 (n = 20) and 2 (n = 30) were completed by normal-hearing civilians. Study 3 (n = 22) was completed by hearing impaired military personnel. The results display good test-retest reliability (95% confidence interval (CI) hearing impairment. The British English CRM using stationary speech-spectrum noise is a "ready to use" SiN test, suitable for investigation as an AFFD assessment tool for military personnel.

  9. Software for Use with Optoelectronic Measuring Tool

    Science.gov (United States)

    Ballard, Kim C.

    2004-01-01

    A computer program has been written to facilitate and accelerate the process of measurement by use of the apparatus described in "Optoelectronic Tool Adds Scale Marks to Photographic Images" (KSC-12201). The tool contains four laser diodes that generate parallel beams of light spaced apart at a known distance. The beams of light are used to project bright spots that serve as scale marks that become incorporated into photographic images (including film and electronic images). The sizes of objects depicted in the images can readily be measured by reference to the scale marks. The computer program is applicable to a scene that contains the laser spots and that has been imaged in a square pixel format that can be imported into a graphical user interface (GUI) generated by the program. It is assumed that the laser spots and the distance(s) to be measured all lie in the same plane and that the plane is perpendicular to the line of sight of the camera used to record the image

  10. Reliability of conditioned pain modulation: a systematic review

    Science.gov (United States)

    Kennedy, Donna L.; Kemp, Harriet I.; Ridout, Deborah; Yarnitsky, David; Rice, Andrew S.C.

    2016-01-01

    Abstract A systematic literature review was undertaken to determine if conditioned pain modulation (CPM) is reliable. Longitudinal, English language observational studies of the repeatability of a CPM test paradigm in adult humans were included. Two independent reviewers assessed the risk of bias in 6 domains; study participation; study attrition; prognostic factor measurement; outcome measurement; confounding and analysis using the Quality in Prognosis Studies (QUIPS) critical assessment tool. Intraclass correlation coefficients (ICCs) less than 0.4 were considered to be poor; 0.4 and 0.59 to be fair; 0.6 and 0.75 good and greater than 0.75 excellent. Ten studies were included in the final review. Meta-analysis was not appropriate because of differences between studies. The intersession reliability of the CPM effect was investigated in 8 studies and reported as good (ICC = 0.6-0.75) in 3 studies and excellent (ICC > 0.75) in subgroups in 2 of those 3. The assessment of risk of bias demonstrated that reporting is not comprehensive for the description of sample demographics, recruitment strategy, and study attrition. The absence of blinding, a lack of control for confounding factors, and lack of standardisation in statistical analysis are common. Conditioned pain modulation is a reliable measure; however, the degree of reliability is heavily dependent on stimulation parameters and study methodology and this warrants consideration for investigators. The validation of CPM as a robust prognostic factor in experimental and clinical pain studies may be facilitated by improvements in the reporting of CPM reliability studies. PMID:27559835

  11. A reliable measure of frailty for a community dwelling older population

    Directory of Open Access Journals (Sweden)

    Fletcher Astrid

    2010-10-01

    Full Text Available Abstract Background Frailty remains an elusive concept despite many efforts to define and measure it. The difficulty in translating the clinical profile of frail elderly people into a quantifiable assessment tool is due to the complex and heterogeneous nature of their health problems. Viewing frailty as a 'latent vulnerability' in older people this study aims to derive a model based measurement of frailty and examines its internal reliability in community dwelling elderly. Method The British Women's Heart and Health Study (BWHHS cohort of 4286 women aged 60-79 years from 23 towns in Britain provided 35 frailty indicators expressed as binary categorical variables. These indicators were corrected for measurement error and assigned relative weights in its association with frailty. Exploratory factor analysis (EFA reduced the data to a smaller number of factors and was subjected to confirmatory factor analysis (CFAwhich restricted the model by fitting the EFA-driven structure to observed data. Cox regression analysis compared the hazard ratios for adverse outcomes of the newly developed British frailty index (FI with a widely known FI. This process was replicated in the MRC Assessment study of older people, a larger cohort drawn from 106 general practices in Britain. Results Seven factors explained the association between frailty indicators: physical ability, cardiac symptoms/disease, respiratory symptoms/disease, physiological measures, psychological problems, co-morbidities and visual impairment. Based on existing concepts and statistical indices of fit, frailty was best described using a General Specific Model. The British FI would serve as a better population metric than the FI as it enables people with varying degrees of frailty to be better distinguished over a wider range of scores. The British FI was a better independent predictor of all-cause mortality, hospitalization and institutionalization than the FI in both cohorts. Conclusions

  12. Measurement methods to assess diastasis of the rectus abdominis muscle (DRAM): A systematic review of their measurement properties and meta-analytic reliability generalisation.

    Science.gov (United States)

    van de Water, A T M; Benjamin, D R

    2016-02-01

    Systematic literature review. Diastasis of the rectus abdominis muscle (DRAM) has been linked with low back pain, abdominal and pelvic dysfunction. Measurement is used to either screen or to monitor DRAM width. Determining which methods are suitable for screening and monitoring DRAM is of clinical value. To identify the best methods to screen for DRAM presence and monitor DRAM width. AMED, Embase, Medline, PubMed and CINAHL databases were searched for measurement property studies of DRAM measurement methods. Population characteristics, measurement methods/procedures and measurement information were extracted from included studies. Quality of all studies was evaluated using 'quality rating criteria'. When possible, reliability generalisation was conducted to provide combined reliability estimations. Thirteen studies evaluated measurement properties of the 'finger width'-method, tape measure, calipers, ultrasound, CT and MRI. Ultrasound was most evaluated. Methodological quality of these studies varied widely. Pearson's correlations of r = 0.66-0.79 were found between calipers and ultrasound measurements. Calipers and ultrasound had Intraclass Correlation Coefficients (ICC) of 0.78-0.97 for test-retest, inter- and intra-rater reliability. The 'finger width'-method had weighted Kappa's of 0.73-0.77 for test-retest reliability, but moderate agreement (63%; weighted Kappa = 0.53) between raters. Comparing calipers and ultrasound, low measurement error was found (above the umbilicus), and the methods had good agreement (83%; weighted Kappa = 0.66) for discriminative purposes. The available information support ultrasound and calipers as adequate methods to assess DRAM. For other methods limited measurement information of low to moderate quality is available and further evaluation of their measurement properties is required. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.

    Directory of Open Access Journals (Sweden)

    Xiangjun Chen

    Full Text Available PURPOSE: To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK eyes and compare the results between these two groups. METHODS: Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs were calculated. Univariate analysis of covariance (ANCOVA was used to compare measured parameters between virgin and post-PRK eyes. RESULTS: The intraocular pressure (IOP, central corneal thickness (CCT and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90 in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88. The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05 and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05 in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05 and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05. CONCLUSIONS: CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.

  14. Reliability and validity of a novel tool to comprehensively assess food and beverage marketing in recreational sport settings.

    Science.gov (United States)

    Prowse, Rachel J L; Naylor, Patti-Jean; Olstad, Dana Lee; Carson, Valerie; Mâsse, Louise C; Storey, Kate; Kirk, Sara F L; Raine, Kim D

    2018-05-31

    Current methods for evaluating food marketing to children often study a single marketing channel or approach. As the World Health Organization urges the removal of unhealthy food marketing in children's settings, methods that comprehensively explore the exposure and power of food marketing within a setting from multiple marketing channels and approaches are needed. The purpose of this study was to test the inter-rater reliability and the validity of a novel settings-based food marketing audit tool. The Food and beverage Marketing Assessment Tool for Settings (FoodMATS) was developed and its psychometric properties evaluated in five public recreation and sport facilities (sites) and subsequently used in 51 sites across Canada for a cross-sectional analysis of food marketing. Raters recorded the count of food marketing occasions, presence of child-targeted and sports-related marketing techniques, and the physical size of marketing occasions. Marketing occasions were classified by healthfulness. Inter-rater reliability was tested using Cohen's kappa (κ) and intra-class correlations (ICC). FoodMATS scores for each site were calculated using an algorithm that represented the theoretical impact of the marketing environment on food preferences, purchases, and consumption. Higher FoodMATS scores represented sites with higher exposure to, and more powerful (unhealthy, child-targeted, sports-related, large) food marketing. Validity of the scoring algorithm was tested through (1) Pearson's correlations between FoodMATS scores and facility sponsorship dollars, and (2) sequential multiple regression for predicting "Least Healthy" food sales from FoodMATS scores. Inter-rater reliability was very good to excellent (κ = 0.88-1.00, p marketing in recreation facilities, the FoodMATS provides a novel means to comprehensively track changes in food marketing environments that can assist in developing and monitoring the impact of policies and interventions.

  15. An integrated approach to human reliability analysis -- decision analytic dynamic reliability model

    International Nuclear Information System (INIS)

    Holmberg, J.; Hukki, K.; Norros, L.; Pulkkinen, U.; Pyy, P.

    1999-01-01

    The reliability of human operators in process control is sensitive to the context. In many contemporary human reliability analysis (HRA) methods, this is not sufficiently taken into account. The aim of this article is that integration between probabilistic and psychological approaches in human reliability should be attempted. This is achieved first, by adopting such methods that adequately reflect the essential features of the process control activity, and secondly, by carrying out an interactive HRA process. Description of the activity context, probabilistic modeling, and psychological analysis form an iterative interdisciplinary sequence of analysis in which the results of one sub-task maybe input to another. The analysis of the context is carried out first with the help of a common set of conceptual tools. The resulting descriptions of the context promote the probabilistic modeling, through which new results regarding the probabilistic dynamics can be achieved. These can be incorporated in the context descriptions used as reference in the psychological analysis of actual performance. The results also provide new knowledge of the constraints of activity, by providing information of the premises of the operator's actions. Finally, the stochastic marked point process model gives a tool, by which psychological methodology may be interpreted and utilized for reliability analysis

  16. Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength.

    Science.gov (United States)

    Vannebo, Katrine Tranaas; Iversen, Vegard Moe; Fimland, Marius Steiro; Mork, Paul Jarle

    2018-03-02

    There is a lack of test-retest reliability studies of measurements of cervical muscle strength, taking into account gender and possible learning effects. To investigate test-retest reliability of measurement of maximal isometric cervical muscle strength by handheld dynamometry. Thirty women (age 20-58 years) and 28 men (age 20-60 years) participated in the study. Maximal isometric strength (neck flexion, neck extension, and right/left lateral flexion) was measured on three separate days at least five days apart by one evaluator. Intra-rater consistency tended to improve from day 1-2 measurements to day 2-3 measurements in both women and men. In women, the intra-class correlation coefficients (ICC) for day 2 to day 3 measurements were 0.91 (95% confidence interval [CI], 0.82-0.95) for neck flexion, 0.88 (95% CI, 0.76-0.94) for neck extension, 0.84 (95% CI, 0.68-0.92) for right lateral flexion, and 0.89 (95% CI, 0.78-0.95) for left lateral flexion. The corresponding ICCs among men were 0.86 (95% CI, 0.72-0.93) for neck flexion, 0.93 (95% CI, 0.85-0.97) for neck extension, 0.82 (95% CI, 0.65-0.91) for right lateral flexion and 0.73 (95% CI, 0.50-0.87) for left lateral flexion. This study describes a reliable and easy-to-administer test for assessing maximal isometric cervical muscle strength.

  17. Intra-rater reliability of hallux flexor strength measures using the Nintendo Wii Balance Board.

    Science.gov (United States)

    Quek, June; Treleaven, Julia; Brauer, Sandra G; O'Leary, Shaun; Clark, Ross A

    2015-01-01

    The purpose of this study was to investigate the intra-rater reliability of a new method in combination with the Nintendo Wii Balance Board (NWBB) to measure the strength of hallux flexor muscle. Thirty healthy individuals (age: 34.9 ± 12.9 years, height: 170.4 ± 10.5 cm, weight: 69.3 ± 15.3 kg, female = 15) participated. Repeated testing was completed within 7 days. Participants performed strength testing in sitting using a wooden platform in combination with the NWBB. This new method was set up to selectively recruit an intrinsic muscle of the foot, specifically the flexor hallucis brevis muscle. Statistical analysis was performed using intra-class coefficients and ordinary least product analysis. To estimate measurement error, standard error of measurement (SEM), minimal detectable change (MDC) and percentage error were calculated. Results indicate excellent intra-rater reliability (ICC = 0.982, CI = 0.96-0.99) with an absence of systematic bias. SEM, MDC and percentage error value were 0.5, 1.4 and 12 % respectively. This study demonstrates that a new method in combination with the NWBB application is reliable to measure hallux flexor strength and has potential to be used for future research and clinical application.

  18. Visual-haptic integration with pliers and tongs: signal ‘weights’ take account of changes in haptic sensitivity caused by different tools

    Directory of Open Access Journals (Sweden)

    Chie eTakahashi

    2014-02-01

    Full Text Available When we hold an object while looking at it, estimates from visual and haptic cues to size are combined in a statistically optimal fashion, whereby the ‘weight’ given to each signal reflects their relative reliabilities. This allows object properties to be estimated more precisely than would otherwise be possible. Tools such as pliers and tongs systematically perturb the mapping between object size and the hand opening. This could complicate visual-haptic integration because it may alter the reliability of the haptic signal, thereby disrupting the determination of appropriate signal weights. To investigate this we first measured the reliability of haptic size estimates made with virtual pliers-like tools (created using a stereoscopic display and force-feedback robots with different ‘gains’ between hand opening and object size. Haptic reliability in tool use was straightforwardly determined by a combination of sensitivity to changes in hand opening and the effects of tool geometry. The precise pattern of sensitivity to hand opening, which violated Weber’s law, meant that haptic reliability changed with tool gain. We then examined whether the visuo-motor system accounts for these reliability changes. We measured the weight given to visual and haptic stimuli when both were available, again with different tool gains, by measuring the perceived size of stimuli in which visual and haptic sizes were varied independently. The weight given to each sensory cue changed with tool gain in a manner that closely resembled the predictions of optimal sensory integration. The results are consistent with the idea that different tool geometries are modelled by the brain, allowing it to calculate not only the distal properties of objects felt with tools, but also the certainty with which those properties are known. These findings highlight the flexibility of human sensory integration and tool-use, and potentially provide an approach for optimising the

  19. [Reliability study in the measurement of the cusp inclination angle of a chairside digital model].

    Science.gov (United States)

    Xinggang, Liu; Xiaoxian, Chen

    2018-02-01

    This study aims to evaluate the reliability of the software Picpick in the measurement of the cusp inclination angle of a digital model. Twenty-one trimmed models were used as experimental objects. The chairside digital impression was then used for the acquisition of 3D digital models, and the software Picpick was employed for the measurement of the cusp inclination of these models. The measurements were repeated three times, and the results were compared with a gold standard, which was a manually measured experimental model cusp angle. The intraclass correlation coefficient (ICC) was calculated. The paired t test value of the two measurement methods was 0.91. The ICCs between the two measurement methods and three repeated measurements were greater than 0.9. The digital model achieved a smaller coefficient of variation (9.9%). The software Picpick is reliable in measuring the cusp inclination of a digital model.

  20. Reliability of perceived neighbourhood conditions and the effects of measurement error on self-rated health across urban and rural neighbourhoods.

    Science.gov (United States)

    Pruitt, Sandi L; Jeffe, Donna B; Yan, Yan; Schootman, Mario

    2012-04-01

    Limited psychometric research has examined the reliability of self-reported measures of neighbourhood conditions, the effect of measurement error on associations between neighbourhood conditions and health, and potential differences in the reliabilities between neighbourhood strata (urban vs rural and low vs high poverty). We assessed overall and stratified reliability of self-reported perceived neighbourhood conditions using five scales (social and physical disorder, social control, social cohesion, fear) and four single items (multidimensional neighbouring). We also assessed measurement error-corrected associations of these conditions with self-rated health. Using random-digit dialling, 367 women without breast cancer (matched controls from a larger study) were interviewed twice, 2-3 weeks apart. Test-retest (intraclass correlation coefficients (ICC)/weighted κ) and internal consistency reliability (Cronbach's α) were assessed. Differences in reliability across neighbourhood strata were tested using bootstrap methods. Regression calibration corrected estimates for measurement error. All measures demonstrated satisfactory internal consistency (α ≥ 0.70) and either moderate (ICC/κ=0.41-0.60) or substantial (ICC/κ=0.61-0.80) test-retest reliability in the full sample. Internal consistency did not differ by neighbourhood strata. Test-retest reliability was significantly lower among rural (vs urban) residents for two scales (social control, physical disorder) and two multidimensional neighbouring items; test-retest reliability was higher for physical disorder and lower for one multidimensional neighbouring item among the high (vs low) poverty strata. After measurement error correction, the magnitude of associations between neighbourhood conditions and self-rated health were larger, particularly in the rural population. Research is needed to develop and test reliable measures of perceived neighbourhood conditions relevant to the health of rural populations.