WorldWideScience

Sample records for reliable mass measurements

  1. Parametric Mass Reliability Study

    Science.gov (United States)

    Holt, James P.

    2014-01-01

    The International Space Station (ISS) systems are designed based upon having redundant systems with replaceable orbital replacement units (ORUs). These ORUs are designed to be swapped out fairly quickly, but some are very large, and some are made up of many components. When an ORU fails, it is replaced on orbit with a spare; the failed unit is sometimes returned to Earth to be serviced and re-launched. Such a system is not feasible for a 500+ day long-duration mission beyond low Earth orbit. The components that make up these ORUs have mixed reliabilities. Components that make up the most mass-such as computer housings, pump casings, and the silicon board of PCBs-typically are the most reliable. Meanwhile components that tend to fail the earliest-such as seals or gaskets-typically have a small mass. To better understand the problem, my project is to create a parametric model that relates both the mass of ORUs to reliability, as well as the mass of ORU subcomponents to reliability.

  2. Mass and Reliability System (MaRS)

    Science.gov (United States)

    Barnes, Sarah

    2016-01-01

    The Safety and Mission Assurance (S&MA) Directorate is responsible for mitigating risk, providing system safety, and lowering risk for space programs from ground to space. The S&MA is divided into 4 divisions: The Space Exploration Division (NC), the International Space Station Division (NE), the Safety & Test Operations Division (NS), and the Quality and Flight Equipment Division (NT). The interns, myself and Arun Aruljothi, will be working with the Risk & Reliability Analysis Branch under the NC Division's. The mission of this division is to identify, characterize, diminish, and communicate risk by implementing an efficient and effective assurance model. The team utilizes Reliability and Maintainability (R&M) and Probabilistic Risk Assessment (PRA) to ensure decisions concerning risks are informed, vehicles are safe and reliable, and program/project requirements are realistic and realized. This project pertains to the Orion mission, so it is geared toward a long duration Human Space Flight Program(s). For space missions, payload is a critical concept; balancing what hardware can be replaced by components verse by Orbital Replacement Units (ORU) or subassemblies is key. For this effort a database was created that combines mass and reliability data, called Mass and Reliability System or MaRS. The U.S. International Space Station (ISS) components are used as reference parts in the MaRS database. Using ISS components as a platform is beneficial because of the historical context and the environment similarities to a space flight mission. MaRS uses a combination of systems: International Space Station PART for failure data, Vehicle Master Database (VMDB) for ORU & components, Maintenance & Analysis Data Set (MADS) for operation hours and other pertinent data, & Hardware History Retrieval System (HHRS) for unit weights. MaRS is populated using a Visual Basic Application. Once populated, the excel spreadsheet is comprised of information on ISS components including

  3. Reliability of BOD POD Measurements Remains High After a Short-Duration Low-Carbohydrate Diet.

    Science.gov (United States)

    Greer, Beau Kjerulf; Edsall, Kathleen M; Greer, Anna E

    2016-04-01

    The purpose of the current study was to determine whether expected changes in body weight via a 3-day low-carbohydrate (LC) diet will disrupt the reliability of air displacement plethysmography measurements via BOD POD. Twenty-four subjects recorded their typical diets for 3 days before BOD POD and 7-site skinfold analyses. Subjects were matched for lean body mass and divided into low-CHO (LC) and control (CON) groups. The LC group was given instruction intended to prevent more than 50 grams/day of carbohydrate consumption for 3 consecutive days, and the CON group replicated their previously recorded diet. Body composition measurements were repeated after dietary intervention. Test-retest reliability measures were significant (p fat percentage in both the LC and the CON groups (rs = .993 and .965, respectively). Likewise, skinfold analysis for body fat percentage reliability was high in both groups (rs = .996 and .997, respectively). There were significant differences between 1st and 2nd BOD POD measurements for body mass (72.9 ± 13.3 vs. 72.1 ± 13.0 kg [M ± SD]) and body volume (69.0 ± 12.7-68.1 ± 12.2 L) in the LC group (p .05) in BOD POD-determined body fat percentage, lean body mass, or fat mass between the 1st and 2nd trial in either group. Body composition measures via BOD POD and 7-site skinfolds remain reliable after 3 days of an LC diet despite significant decreases in body mass.

  4. High-Precision Mass Measurements of Exotic Nuclei with the Triple-Trap Mass Spectrometer Isoltrap

    CERN Multimedia

    Blaum, K; Zuber, K T; Stanja, J

    2002-01-01

    The masses of close to 200 short-lived nuclides have already been measured with the mass spectrometer ISOLTRAP with a relative precision between 1$\\times$10$^{-7}$ and 1$\\times$10^{-8}$. The installatin of a radio-frequency quadrupole trap increased the overall efficiency by two orders of magnitude which is at present about 1%. In a recent upgrade, we installed a carbon cluster laser ion source, which will allow us to use carbon clusters as mass references for absolute mass measurements. Due to these improvements and the high reliability of ISOLTRAP we are now able to perform accurate high-precision mass measurements all over the nuclear chart. We propose therefore mass measurements on light, medium and heavy nuclides on both sides of the valley of stability in the coming four years. ISOLTRAP is presently the only instrument capable of the high precision required for many of the proposed studies.

  5. OSS reliability measurement and assessment

    CERN Document Server

    Yamada, Shigeru

    2016-01-01

    This book analyses quantitative open source software (OSS) reliability assessment and its applications, focusing on three major topic areas: the Fundamentals of OSS Quality/Reliability Measurement and Assessment; the Practical Applications of OSS Reliability Modelling; and Recent Developments in OSS Reliability Modelling. Offering an ideal reference guide for graduate students and researchers in reliability for open source software (OSS) and modelling, the book introduces several methods of reliability assessment for OSS including component-oriented reliability analysis based on analytic hierarchy process (AHP), analytic network process (ANP), and non-homogeneous Poisson process (NHPP) models, the stochastic differential equation models and hazard rate models. These measurement and management technologies are essential to producing and maintaining quality/reliable systems using OSS.

  6. Testing substellar models with dynamical mass measurements

    Directory of Open Access Journals (Sweden)

    Liu M.C.

    2011-07-01

    Full Text Available We have been using Keck laser guide star adaptive optics to monitor the orbits of ultracool binaries, providing dynamical masses at lower luminosities and temperatures than previously available and enabling strong tests of theoretical models. We have identified three specific problems with theory: (1 We find that model color–magnitude diagrams cannot be reliably used to infer masses as they do not accurately reproduce the colors of ultracool dwarfs of known mass. (2 Effective temperatures inferred from evolutionary model radii are typically inconsistent with temperatures derived from fitting atmospheric models to observed spectra by 100–300 K. (3 For the only known pair of field brown dwarfs with a precise mass (3% and age determination (≈25%, the measured luminosities are ~2–3× higher than predicted by model cooling rates (i.e., masses inferred from Lbol and age are 20–30% larger than measured. To make progress in understanding the observed discrepancies, more mass measurements spanning a wide range of luminosity, temperature, and age are needed, along with more accurate age determinations (e.g., via asteroseismology for primary stars with brown dwarf binary companions. Also, resolved optical and infrared spectroscopy are needed to measure lithium depletion and to characterize the atmospheres of binary components in order to better assess model deficiencies.

  7. Twenty-five new mass values from measurements performed with isochronous mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Diwisch, Marcel [Justus-Liebig-Universitaet Giessen (Germany); Knoebel, Ronja; Geissel, Hans; Plass, Wolfgang R.; Scheidenberger, Christoph [Justus-Liebig-Universitaet Giessen (Germany); GSI, Darmstadt (Germany); Patyk, Zygmunt [National Centre for Nuclear Research, NCBJ Swierk, Warszawa (Poland); Weick, Helmut [GSI, Darmstadt (Germany); Collaboration: FRS-ESR-Collaboration

    2016-07-01

    Masses of uranium fission fragments have been measured with the FRS-ESR facility at GSI. In order to increase the mass resolving power and particle identification for non-isochronous particles, Bρ-tagging was applied in one out of two experiments. A new method of data analysis, using a correlation matrix for the combined data set from the two experiments, has provided reliable experimental mass values for 25 different neutron-rich isotopes for the first time. The new masses were obtained for nuclides in the element range from Ge to Ce. The results have been compared with theoretical predictions. At the neutron shell N=82 the comparison of experimental data for tin and cadmium isotopes show both strong shell effects in agreement with spectroscopy experiments and modern shell-model calculations.

  8. Reliability and measurement error of sagittal spinal motion parameters in 220 patients with chronic low back pain using a three-dimensional measurement device.

    Science.gov (United States)

    Mieritz, Rune M; Bronfort, Gert; Jakobsen, Markus D; Aagaard, Per; Hartvigsen, Jan

    2014-09-01

    A basic premise for any instrument measuring spinal motion is that reliable outcomes can be obtained on a relevant sample under standardized conditions. The purpose of this study was to assess the overall reliability and measurement error of regional spinal sagittal plane motion in patients with chronic low back pain (LBP), and then to evaluate the influence of body mass index, examiner, gender, stability of pain, and pain distribution on reliability and measurement error. This study comprises a test-retest design separated by 7 to 14 days. The patient cohort consisted of 220 individuals with chronic LBP. Kinematics of the lumbar spine were sampled during standardized spinal extension-flexion testing using a 6-df instrumented spatial linkage system. Test-retest reliability and measurement error were evaluated using interclass correlation coefficients (ICC(1,1)) and Bland-Altman limits of agreement (LOAs). The overall test-retest reliability (ICC(1,1)) for various motion parameters ranged from 0.51 to 0.70, and relatively wide LOAs were observed for all parameters. Reliability measures in patient subgroups (ICC(1,1)) ranged between 0.34 and 0.77. In general, greater (ICC(1,1)) coefficients and smaller LOAs were found in subgroups with patients examined by the same examiner, patients with a stable pain level, patients with a body mass index less than below 30 kg/m(2), patients who were men, and patients in the Quebec Task Force classifications Group 1. This study shows that sagittal plane kinematic data from patients with chronic LBP may be sufficiently reliable in measurements of groups of patients. However, because of the large LOAs, this test procedure appears unusable at the individual patient level. Furthermore, reliability and measurement error varies substantially among subgroups of patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. The reliability of commonly used electrophysiology measures.

    Science.gov (United States)

    Brown, K E; Lohse, K R; Mayer, I M S; Strigaro, G; Desikan, M; Casula, E P; Meunier, S; Popa, T; Lamy, J-C; Odish, O; Leavitt, B R; Durr, A; Roos, R A C; Tabrizi, S J; Rothwell, J C; Boyd, L A; Orth, M

    Electrophysiological measures can help understand brain function both in healthy individuals and in the context of a disease. Given the amount of information that can be extracted from these measures and their frequent use, it is essential to know more about their inherent reliability. To understand the reliability of electrophysiology measures in healthy individuals. We hypothesized that measures of threshold and latency would be the most reliable and least susceptible to methodological differences between study sites. Somatosensory evoked potentials from 112 control participants; long-latency reflexes, transcranial magnetic stimulation with resting and active motor thresholds, motor evoked potential latencies, input/output curves, and short-latency sensory afferent inhibition and facilitation from 84 controls were collected at 3 visits over 24 months at 4 Track-On HD study sites. Reliability was assessed using intra-class correlation coefficients for absolute agreement, and the effects of reliability on statistical power are demonstrated for different sample sizes and study designs. Measures quantifying latencies, thresholds, and evoked responses at high stimulator intensities had the highest reliability, and required the smallest sample sizes to adequately power a study. Very few between-site differences were detected. Reliability and susceptibility to between-site differences should be evaluated for electrophysiological measures before including them in study designs. Levels of reliability vary substantially across electrophysiological measures, though there are few between-site differences. To address this, reliability should be used in conjunction with theoretical calculations to inform sample size and ensure studies are adequately powered to detect true change in measures of interest. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. History and status of atomic mass measurement and evaluation

    International Nuclear Information System (INIS)

    Huang Wenxue; Zhu Zhichao; Wang Meng; Wang Yue; Tian Yulin; Xu Hushan; Xiao Guoqing

    2010-01-01

    Mass is one of the most fundamental properties that can be obtained about an atomic nucleus. High-accuracy mass values for atoms let us study the atomic and nuclear binding energies that represent the sum of all the atomic and nucleonic interactions. Looking on the history of nuclear masses, it can be found that it is almost as old as that of nuclear physics itself. The experimental methods for masses and the relevant outcomes are so rich that the evaluation is needed to check the consistency among the various results and obtain more reliable data. The atomic mass evaluation is a considerate and complicated process. This paper introduces briefly the history and status of atomic mass measurement and evaluation. (authors)

  11. Mass-balance measurements in Alaska and suggestions for simplified observation programs

    Science.gov (United States)

    Trabant, D.C.; March, R.S.

    1999-01-01

    US Geological Survey glacier fieldwork in Alaska includes repetitious measurements, corrections for leaning or bending stakes, an ability to reliably measure seasonal snow as deep as 10 m, absolute identification of summer surfaces in the accumulation area, and annual evaluation of internal accumulation, internal ablation, and glacier-thickness changes. Prescribed field measurement and note-taking techniques help eliminate field errors and expedite the interpretative process. In the office, field notes are transferred to computerized spread-sheets for analysis, release on the World Wide Web, and archival storage. The spreadsheets have error traps to help eliminate note-taking and transcription errors. Rigorous error analysis ends when mass-balance measurements are extrapolated and integrated with area to determine glacier and basin mass balances. Unassessable errors in the glacier and basin mass-balance data reduce the value of the data set for correlations with climate change indices. The minimum glacier mass-balance program has at least three measurement sites on a glacier and the measurements must include the seasonal components of mass balance as well as the annual balance.

  12. Reliability and mass analysis of dynamic power conversion systems with parallel or standby redundancy

    Science.gov (United States)

    Juhasz, Albert J.; Bloomfield, Harvey S.

    1987-01-01

    A combinatorial reliability approach was used to identify potential dynamic power conversion systems for space mission applications. A reliability and mass analysis was also performed, specifically for a 100-kWe nuclear Brayton power conversion system with parallel redundancy. Although this study was done for a reactor outlet temperature of 1100 K, preliminary system mass estimates are also included for reactor outlet temperatures ranging up to 1500 K.

  13. Reliability and mass analysis of dynamic power conversion systems with parallel of standby redundancy

    Science.gov (United States)

    Juhasz, A. J.; Bloomfield, H. S.

    1985-01-01

    A combinatorial reliability approach is used to identify potential dynamic power conversion systems for space mission applications. A reliability and mass analysis is also performed, specifically for a 100 kWe nuclear Brayton power conversion system with parallel redundancy. Although this study is done for a reactor outlet temperature of 1100K, preliminary system mass estimates are also included for reactor outlet temperatures ranging up to 1500 K.

  14. MEASUREMENT: ACCOUNTING FOR RELIABILITY IN PERFORMANCE ESTIMATES.

    Science.gov (United States)

    Waterman, Brian; Sutter, Robert; Burroughs, Thomas; Dunagan, W Claiborne

    2014-01-01

    When evaluating physician performance measures, physician leaders are faced with the quandary of determining whether departures from expected physician performance measurements represent a true signal or random error. This uncertainty impedes the physician leader's ability and confidence to take appropriate performance improvement actions based on physician performance measurements. Incorporating reliability adjustment into physician performance measurement is a valuable way of reducing the impact of random error in the measurements, such as those caused by small sample sizes. Consequently, the physician executive has more confidence that the results represent true performance and is positioned to make better physician performance improvement decisions. Applying reliability adjustment to physician-level performance data is relatively new. As others have noted previously, it's important to keep in mind that reliability adjustment adds significant complexity to the production, interpretation and utilization of results. Furthermore, the methods explored in this case study only scratch the surface of the range of available Bayesian methods that can be used for reliability adjustment; further study is needed to test and compare these methods in practice and to examine important extensions for handling specialty-specific concerns (e.g., average case volumes, which have been shown to be important in cardiac surgery outcomes). Moreover, it's important to note that the provider group average as a basis for shrinkage is one of several possible choices that could be employed in practice and deserves further exploration in future research. With these caveats, our results demonstrate that incorporating reliability adjustment into physician performance measurements is feasible and can notably reduce the incidence of "real" signals relative to what one would expect to see using more traditional approaches. A physician leader who is interested in catalyzing performance improvement

  15. Calibration measurements using the ORNL fissile mass flow monitor

    International Nuclear Information System (INIS)

    March-Leuba, J.; Uckan, T.; Sumner, J.; Mattingly, J.; Mihalczo, J.

    1998-01-01

    This paper presents a demonstration of fissile-mass-flow measurements using the Oak Ridge National Laboratory (ORNL) Fissile Mass Flow Monitor in the Paducah Gaseous Diffusion Plant (PGDP). This Flow Monitor is part of a Blend Down Monitoring System (BDMS) that will be installed in at least two Russian Federation (R.F.) blending facilities. The key objectives of the demonstration of the ORNL Flow Monitor are two: (a) demonstrate that the ORNL Flow Monitor equipment is capable of reliably monitoring the mass flow rate of 235 UF 6 gas, and (b) provide a demonstration of ORNL Flow Monitor system in operation with UF 6 flow for a visiting R.F. delegation. These two objectives have been met by the PGDP demonstration, as presented in this paper

  16. State of the art and trends of radiometric methods for measuring the mass per unit area

    International Nuclear Information System (INIS)

    Bernhardt, R.

    1984-01-01

    The determination of the mass per unit area by means of transmission or backscattering methods is one of the traditional radioisotope applications. Microelectronics have essentially contributed to the noticeable progress achieved in the development of radiometric instruments for mass per unit area measurements. The use of microcomputers led to both a reliable solution of the main problem of processing the measured data - the correlation of the mass per unit area value with the detector signal under nonlinear calibration conditions - and a considerable increase in the efficiency of the measuring equipment

  17. The W Boson Mass Measurement

    CERN Document Server

    Kotwal, Ashutosh V

    2016-01-01

    The measurement of the W boson mass has been growing in importance as its precision has improved, along with the precision of other electroweak observables and the top quark mass. Over the last decade, the measurement of the W boson mass has been led at hadron colliders. Combined with the precise measurement of the top quark mass at hadron colliders, the W boson mass helped to pin down the mass of the Standard Model Higgs boson through its induced radiative correction on the W boson mass. With the discovery of the Higgs boson and the measurement of its mass, the electroweak sector of the Standard Model is over-constrained. Increasing the precision of the W boson mass probes new physics at the TeV-scale. We summarize an extensive Tevatron (1984–2011) program to measure the W boson mass at the CDF and Dø experiments. We highlight the recent Tevatron measurements and prospects for the final Tevatron measurements.

  18. Limits of reliability for the measurement of integral count

    International Nuclear Information System (INIS)

    Erbeszkorn, L.

    1979-01-01

    A method is presented for exact and approximate calculation of reliability limits of measured nuclear integral count. The formulae are applicable in measuring conditions which assure the Poisson distribution of the counts. The coefficients of the approximate formulae for 90, 95, 98 and 99 per cent reliability levels are given. The exact reliability limits for 90 per cent reliability level are calculated up to 80 integral counts. (R.J.)

  19. Comparison of accelerator mass spectrometric measurement with liquid scintillation counting measurement for the determination of 14C in environmental samples

    International Nuclear Information System (INIS)

    Yasuike, Kaeko; Yamada, Yoshimune; Amano, Hikaru

    2010-01-01

    The concentrations of organically-bound 14 C in tree-ring cellulose of a Japanese Black Pine grown in Shika-machi (37.0 deg. N, 136.8 deg. E) and those of a Japanese Cedar grown in Kanazawa (36.5 deg. N, 136.7 deg. E), Japan, were analyzed for the ring-years from 1989 to 1998 by the accelerator mass spectrometric measurement. The results were compared with those of the same samples analyzed by the liquid scintillation counting measurement to determine the reliability of liquid scintillation counting measurement. An important result of this study is that the sensitivity and reproducibility of accelerator mass spectrometric measurement was almost equal to that of liquid scintillation counting measurement.

  20. Measures of differences in reliability

    International Nuclear Information System (INIS)

    Doksum, K.A.

    1975-01-01

    Measures of differences in reliability of two systems are considered in the scale model, location-scale model, and a nonparametric model. In each model, estimates and confidence intervals are given and some of their properties discussed

  1. Overview of the mass measurements

    International Nuclear Information System (INIS)

    Shull, L.M.

    1991-01-01

    a three-day mass measurement workshop conference sponsored by the INMM was held April 22-24, 1991, in Atlanta, Georgia. DOE Order 5633.3 requires mass measurement control programs for the measurements of nuclear materials but provides little guidance on details for these programs. Measurement principles used for mass are often applicable to other physical property measurements. Westinghouse Savannah River Site (WSRS) personnel organized the workshop conference to facilitate the transfer of mass measurement technology and establish better communications between the calibration laboratories, manufactures, regulators, and scale and balance users in the mass measurement community. Three different formats were used to present the information: a seminar, individual papers, and workshops. The seminar topic was the Process Measurement Assurance Program (PMAP), developed by EG and G Mound Applied Technologies, for determining and controlling measurement errors in manufacturing processes. Paper and workshop topics included: Mass Measurement Techniques and Programs, Selection of equipment and Standards, Standards and Traceability, and Automation in Mass Measurement. The paper gives an overview of the workshop conference, including purpose, participants, and summaries of the seminar, paper, and workshops

  2. Scanning transmission ion microscopy mass measurements for quantitative trace element analysis within biological samples and validation using atomic force microscopy thickness measurements

    Energy Technology Data Exchange (ETDEWEB)

    Deves, Guillaume [Laboratoire de chimie nucleaire analytique et bioenvironnementale, UMR 5084, CNRS-Universite de Bordeaux 1, BP 120 Chemin du solarium, F33175 Gradignan cedex (France)]. E-mail: deves@cenbg.in2p3.fr; Cohen-Bouhacina, Touria [Centre de Physique Moleculaire Optique et Hertzienne, Universite de Bordeaux 1, 351, cours de la Liberation, F33405 Talence cedex (France); Ortega, Richard [Laboratoire de chimie nucleaire analytique et bioenvironnementale, UMR 5084, CNRS-Universite de Bordeaux 1, BP 120 Chemin du solarium, F33175 Gradignan cedex (France)

    2004-10-08

    We used the nuclear microprobe techniques, micro-PIXE (particle-induced X-ray emission), micro-RBS (Rutherford backscattering spectrometry) and scanning transmission ion microscopy (STIM) in order to perform the characterization of trace element content and spatial distribution within biological samples (dehydrated cultured cells, tissues). The normalization of PIXE results was usually expressed in terms of sample dry mass as determined by micro-RBS recorded simultaneously to micro-PIXE. However, the main limit of RBS mass measurement is the sample mass loss occurring during irradiation and which could be up to 30% of the initial sample mass. We present here a new methodology for PIXE normalization and quantitative analysis of trace element within biological samples based on dry mass measurement performed by mean of STIM. The validation of STIM cell mass measurements was obtained in comparison with AFM sample thickness measurements. Results indicated the reliability of STIM mass measurement performed on biological samples and suggested that STIM should be performed for PIXE normalization. Further information deriving from direct confrontation of AFM and STIM analysis could as well be obtained, like in situ measurements of cell specific gravity within cells compartment (nucleolus and cytoplasm)

  3. How to Measure the Onset of Babbling Reliably?

    Science.gov (United States)

    Molemans, Inge; van den Berg, Renate; van Severen, Lieve; Gillis, Steven

    2012-01-01

    Various measures for identifying the onset of babbling have been proposed in the literature, but a formal definition of the exact procedure and a thorough validation of the sample size required for reliably establishing babbling onset is lacking. In this paper the reliability of five commonly used measures is assessed using a large longitudinal…

  4. The Reliability of Anthropometric Measurements Used Preoperatively in Aesthetic Breast Surgery.

    Science.gov (United States)

    Isaac, Kathryn V; Murphy, Blake D; Beber, Brett; Brown, Mitchell

    2016-04-01

    Patient outcomes in aesthetic breast surgery are highly dependent on breast measurements used in preoperative planning. The purpose of this study is to determine the reliability of anthropometric breast measurements. Four raters measured 28 women using 7 measurements: sternal notch to nipple distance (Sn-N), nipple to midline (N-M), nipple to inframammary-fold distance under maximal stretch (N-IMF), breast base width (BW), soft tissue pinch thickness of the upper pole (STPT:UP), STPT at the inframammary fold (STPT:IMF), and anterior pull skin stretch (APSS). Reliability was assessed using intra-class correlation coefficients (ICCs). Inter-rater reliability was excellent for Sn-N, N-M, and BW (ICC = 0.94, 0.90, and 0.76, respectively) and was good for N-IMF (ICC = 0.70). The STPT:UP, STPT:IMF, and APSS measurements were not reliable between raters (ICC reliability was excellent for Sn-N, N-M, and BW for all raters (all ICC > 0.75). The N-IMF intra-rater reliability was excellent in senior raters (ICC > 0.75) and good in junior raters (ICC > 0.6). The STPT:UP, STPT:IMF, and APSS measurements showed fair or poor reliability for most raters (ICC reliable. Dynamic measurements including APSS, STPT:UP, and STUP:IMF are unreliable. N-IMF is the only reliable dynamic measurement, and its reliability improves with increasing clinical experience. The variable reliability of preoperative measurements must be considered in the planning of aesthetic breast surgery. 4 Diagnostic. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  5. Estimatining biases in the stellar dynamical black hole mass measurements in barred galaxies and prospects for measuring SMBH masses with JWST

    Science.gov (United States)

    Valluri, Monica; Vasiliev, Eugene; Bentz, Misty; Shen, Juntai

    2018-04-01

    Although 60% of disk galaxies are barred, stellar dynamical measurements of the masses of supermassive black holes (SMBH) in barred galaxies have always been obtained under the assumption that the bulges are axisymmetric. We use N-body simulations with self-consistently grown SMBHs in barred and unbarred galaxies to create a suite of mock Integral Field Spectrographic (IFS) datasets for galaxies with various observed orientations. We then apply an axisymmetric orbit superposition code to these mock IFS datasets to assess the reliability with which SMBH masses can be recovered. We also assess which disk and bar orientations give rise to biases. We use these simulations to assess whether or not existing SMBH measurements in barred galaxies are likely to be biased. We also present a brief preview of our JWST Early Release Science proposal to study the nuclear dynamics of nearby Seyfert I galaxy NGC 4151 with the NIRSpec Integral Field Spectrograph and describe how simulations of disk galaxies will used to create mock NIRSpec data to prepare for the real data.

  6. Test-retest reliability for aerodynamic measures of voice.

    Science.gov (United States)

    Awan, Shaheen N; Novaleski, Carolyn K; Yingling, Julie R

    2013-11-01

    The purpose of this study was to investigate the intrasubject reliability of aerodynamic characteristics of the voice within typical/normal speakers across testing sessions using the Phonatory Aerodynamic System (PAS 6600; KayPENTAX, Montvale, NJ). Participants were 60 healthy young adults (30 males and 30 females) between the ages 18 and 31 years with perceptually typical voice. Participants were tested using the PAS 6600 (Phonatory Aerodynamic System) on two separate days with approximately 1 week between each session at approximately the same time of day. Four PAS protocols were conducted (vital capacity, maximum sustained phonation, comfortable sustained phonation, and voicing efficiency) and measures of expiratory volume, maximum phonation time, mean expiratory airflow (during vowel production) and target airflow (obtained via syllable repetition), peak air pressure, aerodynamic power, aerodynamic resistance, and aerodynamic efficiency were obtained during each testing session. Associated acoustic measures of vocal intensity and frequency were also collected. All phonations were elicited at comfortable pitch and loudness. All aerodynamic and associated variables evaluated in this study showed useable test-retest reliability (ie, intraclass correlation coefficients [ICCs] ≥ 0.60). A high degree of mean test-retest reliability was found across all subjects for aerodynamic and associated acoustic measurements of vital capacity, maximum sustained phonation, glottal resistance, and vocal intensity (all with ICCs > 0.75). Although strong ICCs were observed for measures of glottal power and mean expiratory airflow in males, weaker overall results for these measures (ICC range: 0.60-0.67) were observed in females subjects and sizable coefficients of variation were observed for measures of power, resistance, and efficiency in both men and women. Differences in degree of reliability from measure to measure were revealed in greater detail using methods such as ICCs and

  7. Some mass measurement problems

    International Nuclear Information System (INIS)

    Merritt, J.S.

    1976-01-01

    Concerning the problem of determining the thickness of a target, an uncomplicated approach is to measure its mass and area and take the quotient. This paper examines the mass measurement aspect of such an approach. (author)

  8. Reliability of infrared thermometric measurements of skin temperature in the hand.

    Science.gov (United States)

    Packham, Tara L; Fok, Diana; Frederiksen, Karen; Thabane, Lehana; Buckley, Norman

    2012-01-01

    Clinical measurement study. Skin temperature asymmetries (STAs) are used in the diagnosis of complex regional pain syndrome (CRPS), but little evidence exists for reliability of the equipment and methods. This study examined the reliability of an inexpensive infrared (IR) thermometer and measurement points in the hand for the study of STA. ST was measured three times at five points on both hands with an IR thermometer by two raters in 20 volunteers (12 normals and 8 CRPS). ST measurement results using IR thermometers support inter-rater reliability: intraclass correlation coefficient (ICC) estimate for single measures 0.80; all ST measurement points were also highly reliable (ICC single measures, 0.83-0.91). The equipment demonstrated excellent reliability, with little difference in the reliability of the five measurement sites. These preliminary findings support their use in future CRPS research. Not applicable. Copyright © 2012 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  9. TWO CRITERIA FOR GOOD MEASUREMENTS IN RESEARCH: VALIDITY AND RELIABILITY

    Directory of Open Access Journals (Sweden)

    Haradhan Kumar Mohajan

    2017-12-01

    Full Text Available Reliability and validity are two most important and fundamental features in the evaluation of any measurement instrument or toll for a good research. The purpose of this research is to discuss the validity and reliability of measurement instruments that are used in research. Validity concerns what an instrument measures, and how well it does so. Reliability concerns the faith that one can have in the data obtained from use of an instrument, that is, the degree to which any measuring tool controls for random error. An attempt has been taken here to review the reliability and validity, and threat to them in some details.

  10. Cortisol production rates measured by liquid chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Esteban, N.V.; Yergey, A.L.

    1990-01-01

    Cortisol production rates (FPRs) in physiologic and pathologic states in humans have been investigated over the past 30 years. However, there has been conflicting evidence concerning the validity of the currently accepted value of FPRs in humans (12 to 15 mg/m2/d) as determined by radiotracer methodology. The present study reviews previous methods proposed for the measurement of FPRs in humans and discusses the applications of the first method for the direct determination of 24-hour plasma FPRs during continuous administration of a stable isotope, using a thermospray high-pressure liquid chromatography-mass spectrometry technique. The technique is fast, sensitive, and, unlike gas chromatography-mass spectrometry methods, does not require derivatization, allowing on-line detection and quantification of plasma cortisol after a simple extraction procedure. The results of determination of plasma FPRs by stable tracer/mass spectrometry are directly in units of mass/time and, unlike radiotracer methods, are independent of any determination of volume of distribution or cortisol concentration. Our methodology offers distinct advantages over radiotracer techniques in simplicity and reliability since only single measurements of isotope ratios are required. The technique was validated in adrenalectomized patients. Circadian variations in daily FRPs were observed in normal volunteers, and, to date, results suggest a lower FRP in normal children and adults than previously believed. 88 references

  11. Developing safety performance functions incorporating reliability-based risk measures.

    Science.gov (United States)

    Ibrahim, Shewkar El-Bassiouni; Sayed, Tarek

    2011-11-01

    Current geometric design guides provide deterministic standards where the safety margin of the design output is generally unknown and there is little knowledge of the safety implications of deviating from these standards. Several studies have advocated probabilistic geometric design where reliability analysis can be used to account for the uncertainty in the design parameters and to provide a risk measure of the implication of deviation from design standards. However, there is currently no link between measures of design reliability and the quantification of safety using collision frequency. The analysis presented in this paper attempts to bridge this gap by incorporating a reliability-based quantitative risk measure such as the probability of non-compliance (P(nc)) in safety performance functions (SPFs). Establishing this link will allow admitting reliability-based design into traditional benefit-cost analysis and should lead to a wider application of the reliability technique in road design. The present application is concerned with the design of horizontal curves, where the limit state function is defined in terms of the available (supply) and stopping (demand) sight distances. A comprehensive collision and geometric design database of two-lane rural highways is used to investigate the effect of the probability of non-compliance on safety. The reliability analysis was carried out using the First Order Reliability Method (FORM). Two Negative Binomial (NB) SPFs were developed to compare models with and without the reliability-based risk measures. It was found that models incorporating the P(nc) provided a better fit to the data set than the traditional (without risk) NB SPFs for total, injury and fatality (I+F) and property damage only (PDO) collisions. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Black-Hole Mass Measurements

    DEFF Research Database (Denmark)

    Vestergaard, Marianne

    2004-01-01

    The applicability and apparent uncertainties of the techniques currently available for measuring or estimating black-hole masses in AGNs are briefly summarized.......The applicability and apparent uncertainties of the techniques currently available for measuring or estimating black-hole masses in AGNs are briefly summarized....

  13. Organ mass measurements

    International Nuclear Information System (INIS)

    Kawamura, H.

    1998-01-01

    The term, anatomical measurements, in the context of this Co-ordinated Research Programme refers to measurements of masses of internal organs, although the human body is composed of internal organs and tissues such as skeleton, muscle, skin and adipose. The mass of an organ containing a radionuclide (source organ), and the mass of a target organ which absorbs energy of the radiation, are essential parameters in the ICRP dosimetric model derived from the MIRD method. Twelve specific organs of interest were proposed at the Coordinated Research Programme Project Formulation Meeting (PFM) in 1988. A slightly different set of thirteen organs with potential significance for radiation protection were selected for study at the Research Co-ordination Meeting held at the Bhabha Atomic Research Centre in 1991. The dimensions of the organs could also be useful information, but were considered unimportant for internal dose assessment. Due to the strong concern about the unified method for collecting organ mass data at the PFM, a guide-line was established stressing the need for organ data from subjects that were healthy and normal, at least until shortly before death, or from sudden death cases, following the Japanese experience. In this report, masses of nine to thirteen organs are presented from seven participating countries. Three participants have also reported the organ masses as fractions of the total body mass

  14. Measuring Passenger Travel Time Reliability using Smartcard Data

    NARCIS (Netherlands)

    Bagherian, M.; Cats, O.; van Oort, N.; Hickman, M

    2016-01-01

    Service reliability is a key performance measure for transit agencies in increasing their service quality and thus ridership. Conventional reliability metrics are established based on vehicle movements and thus do not adequately reflect passenger’s experience. In the past few years, the growing

  15. Reliability importance measures and their calculation

    International Nuclear Information System (INIS)

    Andsten, R.; Vaurio, J.K.

    1989-01-01

    The importance of a component to the system reliability or availability and to the system failure rate can be measured by a number of importance measures. Such measures can be used to guide the system design improvement actions as well as the diagnostic and repair actions. This report develops relationships between several importance measures, illustrates their meaning with interpretations and applications, and describes the computer program called IMPO that calculates importance measures when the system minimum cat sets and component parameters are given. A user's manual is included with illustrative examples

  16. Top quark mass measurements with CMS

    CERN Document Server

    Kovalchuk, Nataliia

    2017-01-01

    Measurements of the top quark mass are presented, obtained from CMS data collected in proton-proton collisions at the LHC at centre-of-mass energies of 7 TeV and 8 TeV. The mass of the top quark is measured using several methods and channels, including the reconstructed invariant mass distribution of the top quark, an analysis of endpoint spectra as well as measurements from shapes of top quark decay distributions. The dependence of the mass measurement on the kinematic phase space is investigated. The results of the various channels are combined and compared to the world average. The top mass and also $\\alpha_{\\textnormal S}$ are extracted from the top pair cross section measured at CMS.

  17. Role of clinical indications of bone mass measurement with bi-photonic X-ray absorptiometry. Interet et indications cliniques des mesures de masse osseuse par absorptiometrie biphotonique a rayons X

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    Bone densitometry by precise, reliable and non-traumatic methods such as X-ray bi-phonon absorptiometry, is the only way to predict osteoporosis fractures risks. The whole epidemiological studies establish that bone mass loss and osteoporosis risk are directly linked. The measurement of the bone mass is the basis of osteoporosis prevention for elderly women, and of other clinical situations. This paper gives, by a critical analysis of available data, advantages and limits of bone mass measurements by X-ray bi-phonon absorptiometry, and essential clinical indications. (A.B.). 181 refs.

  18. Intrarater and interrater reliability for measurements in videofluoroscopy of swallowing

    International Nuclear Information System (INIS)

    Baijens, Laura; Barikroo, Ali; Pilz, Walmari

    2013-01-01

    Objective: Intrarater and interrater reliability is crucial to the quality of diagnostic and therapy-effect studies. This paper reports on a systematic review of studies on intrarater and interrater reliability for measurements in videofluoroscopy of swallowing. The aim of this review was to summarize and qualitatively analyze published studies on that topic. Materials and methods: Those published up to March 2013 were found through a comprehensive electronic database search using PubMed, Embase, and The Cochrane Library. Two reviewers independently assessed the studies using strict inclusion criteria. Results: Nineteen studies were included and then qualitatively analyzed. In several of these, methodological problems were found. Moreover, intrarater and interrater reliability varied with the measure applied. A meta-analysis was not carried out as studies were not of sufficient quality to warrant doing so. Conclusion: In order to achieve reliable measurements in videofluoroscopy of swallowing, it is recommended that raters use well-defined guidelines for the levels of ordinal visuoperceptual variables. Furthermore, in order to make the measurements reliable (intrarater and interrater) it is recommended that, following protocolled pre-experimental training, the raters should have maximum consensus about the definition of the measured variables

  19. Intrarater and interrater reliability for measurements in videofluoroscopy of swallowing

    Energy Technology Data Exchange (ETDEWEB)

    Baijens, Laura, E-mail: laura.baijens@mumc.nl [Department of Otorhinolaryngology, Head and Neck Surgery, Maastricht University Medical Center, Maastricht (Netherlands); Barikroo, Ali, E-mail: a.Barikroo@ufl.edu [Swallowing Research Laboratory, Department of Speech, Language and Hearing Sciences, College of Public Health and Health Professions, University of Florida, Gainesville, FL (United States); Pilz, Walmari, E-mail: walmari.pilz@mumc.nl [Department of Otorhinolaryngology, Head and Neck Surgery, Maastricht University Medical Center, Maastricht (Netherlands)

    2013-10-01

    Objective: Intrarater and interrater reliability is crucial to the quality of diagnostic and therapy-effect studies. This paper reports on a systematic review of studies on intrarater and interrater reliability for measurements in videofluoroscopy of swallowing. The aim of this review was to summarize and qualitatively analyze published studies on that topic. Materials and methods: Those published up to March 2013 were found through a comprehensive electronic database search using PubMed, Embase, and The Cochrane Library. Two reviewers independently assessed the studies using strict inclusion criteria. Results: Nineteen studies were included and then qualitatively analyzed. In several of these, methodological problems were found. Moreover, intrarater and interrater reliability varied with the measure applied. A meta-analysis was not carried out as studies were not of sufficient quality to warrant doing so. Conclusion: In order to achieve reliable measurements in videofluoroscopy of swallowing, it is recommended that raters use well-defined guidelines for the levels of ordinal visuoperceptual variables. Furthermore, in order to make the measurements reliable (intrarater and interrater) it is recommended that, following protocolled pre-experimental training, the raters should have maximum consensus about the definition of the measured variables.

  20. Reliability of radiographic measurement of lateral capitellohumeral angle in healthy children.

    Science.gov (United States)

    Hasegawa, Masaki; Suzuki, Taku; Kuroiwa, Takashi; Oka, Yusuke; Maeda, Atsushi; Takeda, Hiroki; Shizu, Kanae; Tsuji, Takashi; Suzuki, Katsuji; Yamada, Harumoto

    2018-04-01

    This retrospective cohort study was designed to validate the reliability of measurement of the lateral capitellohumeral angle (LCHA), an index of sagittal angulation of the elbow, in healthy children. The results were compared to the Baumann angle (BA), which is a similar concept to LCHA.Sixty-two radiographs of the elbow in healthy children (range, 2-11 years) were reviewed by 6 examiners at 2 sessions. The mean value and reliability of the measurement of LCHA and BA were assessed. Intraobserver reliability and interobserver reliability were calculated using intraclass correlation coefficients (ICCs).The mean LCHA value was 45° (range, 22° to 70°) and the mean BA was 71° (range, 56° to 86°). The ICCs for intraobserver reliability of the LCHA measurements were almost perfect for 2 examiners, substantial for 3 examiners, and moderate for 1 examiner with a mean value of 0.77 (range, 0.57-0.95). For BA measurements, the ICCs were almost perfect for 1 examiner and substantial for 5 examiners with a mean value of 0.74 (range, 0.66-0.83). The ICCs for interobserver reliability between the first and second measurements were both moderate for LCHA (0.56 and 0.51) and for BA (0.52 and 0.50).LCHA showed almost the same reliability in measurement as BA, which is the gold standard assessment for coronal alignment of the elbow. LCHA showed moderate-to-good reliability in the evaluation of sagittal plane elbow alignment.

  1. Mass measurement of radioactive isotopes

    CERN Document Server

    Kluge, H J; Scheidenberger, C

    2004-01-01

    The highest precision in mass measurements on short-lived radionuclides is obtained using trapping and cooling techniques. Here, the experimental storage ring (ESR) at GSI/Darmstadt and the tandem Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN play an important role. Status and recent results on mass measurements of radioactive nuclides with ESR and ISOLTRAP are summarized.

  2. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity

    Directory of Open Access Journals (Sweden)

    Adebisi Bisi-Balogun

    2016-04-01

    Full Text Available This study aimed to determine the relative and absolute reliability of ultrasound (US measurements of the thickness and echogenicity of the plantar fascia (PF at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.

  3. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity.

    Science.gov (United States)

    Bisi-Balogun, Adebisi; Cassel, Michael; Mayer, Frank

    2016-04-13

    This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.

  4. Top quark mass measurement and color effects at the LHC

    International Nuclear Information System (INIS)

    Kovalchuk, Nataliia

    2018-04-01

    The top quark, the heaviest fundamental particle discovered to date, is one of the most peculiar particles that were discovered so far. It plays a crucial role in consistency checks of the Standard Model and in searches for new physics, e.g., supersymmetry, composite Higgs, and many other exotic models. In this thesis, an important property of the top quark is measured: the mass. This analysis is based on the data recorded at a center-of-mass energy of 13 TeV in 2016 with the CMS detector at the CERN LHC, and corresponds to an integrated luminosity of 35.9 fb -1 . The mass of the top quark is measured using the top quark pair event candidate, which corresponds to events with one muon or electron and at least four jets. The corresponding decay products are used in a kinematic fit to perform the jet quark assignment, increase the fraction of correctly reconstructed top quarks and to improve the mass resolution. Using the ideogram method the top quark mass is measured simultaneously with the jet scale factor (JSF), constrained by the jets arising from the W boson decay. The estimated result is calibrated with samples simulated with a next-to-leading order matrix element generator matched to the parton shower. The top quark mass is measured to be m t =172.25±0.08 (stat+JSF)±0.62 (syst) GeV. The results are tested for possible kinematic dependence by performing measurements of the top quark mass in different phase space regions. The residual data-to-simulation calibration of the energy of the jets is also estimated from dijet events with data collected at center-of-mass energy of 13 TeV in 2015 with the CMS detector corresponding to an integrated luminosity of 2.1 fb -1 . The corrections are performed using selected back-to-back dijet events by the MPF and dijet balance methods and are found to differ from unity by less then 3% in the barrel region and up to 17% in the endcap and forward regions of the detector. This result was used in the top mass measurement

  5. A black-hole mass measurement from molecular gas kinematics in NGC4526.

    Science.gov (United States)

    Davis, Timothy A; Bureau, Martin; Cappellari, Michele; Sarzi, Marc; Blitz, Leo

    2013-02-21

    The masses of the supermassive black holes found in galaxy bulges are correlated with a multitude of galaxy properties, leading to suggestions that galaxies and black holes may evolve together. The number of reliably measured black-hole masses is small, and the number of methods for measuring them is limited, holding back attempts to understand this co-evolution. Directly measuring black-hole masses is currently possible with stellar kinematics (in early-type galaxies), ionized-gas kinematics (in some spiral and early-type galaxies) and in rare objects that have central maser emission. Here we report that by modelling the effect of a black hole on the kinematics of molecular gas it is possible to fit interferometric observations of CO emission and thereby accurately estimate black-hole masses. We study the dynamics of the gas in the early-type galaxy NGC 4526, and obtain a best fit that requires the presence of a central dark object of 4.5(+4.2)(-3.1) × 10(8) solar masses (3σ confidence limit). With the next-generation millimetre-wavelength interferometers these observations could be reproduced in galaxies out to 75 megaparsecs in less than 5 hours of observing time. The use of molecular gas as a kinematic tracer should thus allow one to estimate black-hole masses in hundreds of galaxies in the local Universe, many more than are accessible with current techniques.

  6. Inter-rater reliability of shoulder measurements in middle-aged women.

    Science.gov (United States)

    De Groef, A; Van Kampen, M; Vervloesem, N; Clabau, E; Christiaens, M-R; Neven, P; Geraerts, I; Struyf, F; Devoogdt, N

    2017-06-01

    To investigate inter-rater reliability of a set of shoulder measurements including inclinometry [shoulder range of motion (ROM)], acromion-table distance and pectoralis minor muscle length (static scapular positioning), upward rotation with two inclinometers (scapular kinematics) and pain pressure thresholds (muscle tenderness) in middle-aged women. Observational study. Thirty symptom-free middle-aged women (first cohort) were measured by two raters. All measurements with an intraclass correlation coefficient (ICC) below 0.75 were retested after an additional training period in a second cohort of 30 symptom-free middle-aged women. Inter-rater reliability of all variables was measured with the ICC (95% confidence interval) and standard error of measurement (SEM). Acromion-table distance (ICC=0.91, SEM 0.22 to 0.28% of body length), pectoralis minor muscle length (ICC=0.91, SEM 0.16% of body length), pain pressure thresholds (ICC=0.78 to 0.85, SEM 0.39 to 0.70kg) and abduction ROM (ICC=0.77, SEM 5°) showed good to excellent inter-rater reliability in the first cohort. After an additional training period, forward flexion ROM showed good inter-rater reliability (ICC=0.83, SEM 5°), scapular upward rotation in resting position showed moderate reliability (ICC=0.52, SEM 2°), and other scaption angles showed weak reliability (ICC=0.26 to 0.43, SEM 3 to 8°). In a battery of clinical tools to evaluate factors contributing to shoulder pain, static scapular positioning and pressure pain thresholds were found to have good to excellent inter-rater reliability in middle-aged women. Additional training is recommended for measurements with a gravity inclinometer. Copyright © 2016 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  7. Top quark mass measurement

    International Nuclear Information System (INIS)

    Maki, Tuula; Helsinki Inst. of Phys.; Helsinki U. of Tech.

    2008-01-01

    The top quark is the heaviest elementary particle. Its mass is one of the fundamental parameters of the standard model of particle physics, and an important input to precision electroweak tests. This thesis describes three measurements of the top-quark mass in the dilepton decay channel. The dilepton events have two neutrinos in the final state; neutrinos are weakly interacting particles that cannot be detected with a multipurpose experiment. Therefore, the signal of dilepton events consists of a large amount of missing energy and momentum carried off by the neutrinos. The top-quark mass is reconstructed for each event by assuming an additional constraint from a top mass independent distribution. Template distributions are constructed from simulated samples of signal and background events, and parameterized to form continuous probability density functions. The final top-quark mass is derived using a likelihood fit to compare the reconstructed top mass distribution from data to the parameterized templates. One of the analyses uses a novel technique to add top mass information from the observed number of events by including a cross-section-constraint in the likelihood function. All measurements use data samples collected by the CDF II detector

  8. Intra- and interobserver reliability of quantitative ultrasound measurement of the plantar fascia.

    Science.gov (United States)

    Rathleff, Michael Skovdal; Moelgaard, Carsten; Lykkegaard Olesen, Jens

    2011-01-01

    To determine intra- and interobserver reliability and measurement precision of sonographic assessment of plantar fascia thickness when using one, the mean of two, or the mean of three measurements. Two experienced observers scanned 20 healthy subjects twice with 60 minutes between test and retest. A GE LOGIQe ultrasound scanner was used in the study. The built-in software in the scanner was used to measure the thickness of the plantar fascia (PF). Reliability was calculated using intraclass correlation coefficient (ICC) and limits of agreement (LOA). Intraobserver reliability (ICC) using one measurement was 0.50 for one observer and 0.52 for the other, and using the mean of three measurements intraobserver reliability increased up to 0.77 and 0.67, respectively. Interobserver reliability (ICC) when using one measurement was 0.62 and increased to 0.82 when using the average of three measurements. LOA showed that when using the average of three measurements, LOA decreased to 0.6 mm, corresponding to 17.5% of the mean thickness of the PF. The results showed that reliability increases when using the mean of three measurements compared with one. Limits of agreement based on intratester reliability shows that changes in thickness that are larger than 0.6 mm can be considered actual changes in thickness and not a result of measurement error. Copyright © 2011 Wiley Periodicals, Inc.

  9. Reliability of Wearable Inertial Measurement Units to Measure Physical Activity in Team Handball.

    Science.gov (United States)

    Luteberget, Live S; Holme, Benjamin R; Spencer, Matt

    2018-04-01

    To assess the reliability and sensitivity of commercially available inertial measurement units to measure physical activity in team handball. Twenty-two handball players were instrumented with 2 inertial measurement units (OptimEye S5; Catapult Sports, Melbourne, Australia) taped together. They participated in either a laboratory assessment (n = 10) consisting of 7 team handball-specific tasks or field assessment (n = 12) conducted in 12 training sessions. Variables, including PlayerLoad™ and inertial movement analysis (IMA) magnitude and counts, were extracted from the manufacturers' software. IMA counts were divided into intensity bands of low (1.5-2.5 m·s -1 ), medium (2.5-3.5 m·s -1 ), high (>3.5 m·s -1 ), medium/high (>2.5 m·s -1 ), and total (>1.5 m·s -1 ). Reliability between devices and sensitivity was established using coefficient of variation (CV) and smallest worthwhile difference (SWD). Laboratory assessment: IMA magnitude showed a good reliability (CV = 3.1%) in well-controlled tasks. CV increased (4.4-6.7%) in more-complex tasks. Field assessment: Total IMA counts (CV = 1.8% and SWD = 2.5%), PlayerLoad (CV = 0.9% and SWD = 2.1%), and their associated variables (CV = 0.4-1.7%) showed a good reliability, well below the SWD. However, the CV of IMA increased when categorized into intensity bands (2.9-5.6%). The reliability of IMA counts was good when data were displayed as total, high, or medium/high counts. A good reliability for PlayerLoad and associated variables was evident. The CV of the previously mentioned variables was well below the SWD, suggesting that OptimEye's inertial measurement unit and its software are sensitive for use in team handball.

  10. Precision of lumbar intervertebral measurements: does a computer-assisted technique improve reliability?

    Science.gov (United States)

    Pearson, Adam M; Spratt, Kevin F; Genuario, James; McGough, William; Kosman, Katherine; Lurie, Jon; Sengupta, Dilip K

    2011-04-01

    Comparison of intra- and interobserver reliability of digitized manual and computer-assisted intervertebral motion measurements and classification of "instability." To determine if computer-assisted measurement of lumbar intervertebral motion on flexion-extension radiographs improves reliability compared with digitized manual measurements. Many studies have questioned the reliability of manual intervertebral measurements, although few have compared the reliability of computer-assisted and manual measurements on lumbar flexion-extension radiographs. Intervertebral rotation, anterior-posterior (AP) translation, and change in anterior and posterior disc height were measured with a digitized manual technique by three physicians and by three other observers using computer-assisted quantitative motion analysis (QMA) software. Each observer measured 30 sets of digital flexion-extension radiographs (L1-S1) twice. Shrout-Fleiss intraclass correlation coefficients for intra- and interobserver reliabilities were computed. The stability of each level was also classified (instability defined as >4 mm AP translation or 10° rotation), and the intra- and interobserver reliabilities of the two methods were compared using adjusted percent agreement (APA). Intraobserver reliability intraclass correlation coefficients were substantially higher for the QMA technique THAN the digitized manual technique across all measurements: rotation 0.997 versus 0.870, AP translation 0.959 versus 0.557, change in anterior disc height 0.962 versus 0.770, and change in posterior disc height 0.951 versus 0.283. The same pattern was observed for interobserver reliability (rotation 0.962 vs. 0.693, AP translation 0.862 vs. 0.151, change in anterior disc height 0.862 vs. 0.373, and change in posterior disc height 0.730 vs. 0.300). The QMA technique was also more reliable for the classification of "instability." Intraobserver APAs ranged from 87 to 97% for QMA versus 60% to 73% for digitized manual

  11. Reliability of reflectance measures in passive filters

    Science.gov (United States)

    Saldiva de André, Carmen Diva; Afonso de André, Paulo; Rocha, Francisco Marcelo; Saldiva, Paulo Hilário Nascimento; Carvalho de Oliveira, Regiani; Singer, Julio M.

    2014-08-01

    Measurements of optical reflectance in passive filters impregnated with a reactive chemical solution may be transformed to ozone concentrations via a calibration curve and constitute a low cost alternative for environmental monitoring, mainly to estimate human exposure. Given the possibility of errors caused by exposure bias, it is common to consider sets of m filters exposed during a certain period to estimate the latent reflectance on n different sample occasions at a certain location. Mixed models with sample occasions as random effects are useful to analyze data obtained under such setups. The intra-class correlation coefficient of the mean of the m measurements is an indicator of the reliability of the latent reflectance estimates. Our objective is to determine m in order to obtain a pre-specified reliability of the estimates, taking possible outliers into account. To illustrate the procedure, we consider an experiment conducted at the Laboratory of Experimental Air Pollution, University of São Paulo, Brazil (LPAE/FMUSP), where sets of m = 3 filters were exposed during 7 days on n = 9 different occasions at a certain location. The results show that the reliability of the latent reflectance estimates for each occasion obtained under homoskedasticity is km = 0.74. A residual analysis suggests that the within-occasion variance for two of the occasions should be different from the others. A refined model with two within-occasion variance components was considered, yielding km = 0.56 for these occasions and km = 0.87 for the remaining ones. To guarantee that all estimates have a reliability of at least 80% we require measurements on m = 10 filters on each occasion.

  12. Quantitative measurement of hypertrophic scar: interrater reliability and concurrent validity.

    Science.gov (United States)

    Nedelec, Bernadette; Correa, José A; Rachelska, Grazyna; Armour, Alexis; LaSalle, Léo

    2008-01-01

    Research into the pathophysiology and treatment of hypertrophic scar (HSc) remains limited by the heterogeneity of scar and the imprecision with which its severity is measured. The objective of this study was to test the interrater reliability and concurrent validity of the Cutometer measurement of elasticity, the Mexameter measurement of erythema and pigmentation, and total thickness measure of the DermaScan C relative to the modified Vancouver Scar Scale (mVSS) in patient-matched normal skin, normal scar, and HSc. Three independent investigators evaluated 128 sites (severe HSc, moderate or mild HSc, donor site, and normal skin) on 32 burn survivors using all of the above measurement tools. The intraclass correlation coefficient, which was used to measure interrater reliability, reflects the inherent amount of error in the measure and is considered acceptable when it is >0.75. Interrater reliability of the totals of the height, pliability, and vascularity subscales of the mVSS fell below the acceptable limit ( congruent with0.50). The individual subscales of the mVSS fell well below the acceptable level (0.89) for each study site with the exception of severe scar. Mexameter and DermaScan C reliability measurements were acceptable for all sites (>0.82). Concurrent validity correlations with the mVSS were significant except for the comparison of the mVSS pliability subscale and the Cutometer maximum deformation measure comparison in severe scar. In conclusion, the Mexameter and DermaScan C measurements of scar color and thickness of all sites, as well as the Cutometer measurement of elasticity in all but the most severe scars shows high interrater reliability. Their significant concurrent validity with the mVSS confirms that these tools are measuring the same traits as the mVSS, and in a more objective way.

  13. Measurement of the top quark mass

    International Nuclear Information System (INIS)

    Blusk, Steven R.

    1998-01-01

    The first evidence and subsequent discovery of the top quark was reported nearly 4 years ago. Since then, CDF and D0 have analyzed their full Run 1 data samples, and analysis techniques have been refined to make optimal use of the information. In this paper, we report on the most recent measurements of the top quark mass, performed by the CDF and D0 collaborations at the Fermilab Tevatron. The CDF collaboration has performed measurements of the top quark mass in three decay channels from which the top quark mass is measured to be 175.5 ± 6.9 GeV=c 2 . The D0 collaboration combines measurements from two decay channels to obtain a top quark mass of 172.1 ± 7.1 GeV/c 2 . Combining the measurements from the two experiments, assuming a 2 GeV GeV/c 2 correlated systematic uncertainty, the measurement of the top quark mass at the Tevatron is 173.9 ± 5.2 GeV/c 2 . This report presents the measurements of the top quark mass from each of the decay channels which contribute to this measurement

  14. Mass Customization Measurements Metrics

    DEFF Research Database (Denmark)

    Nielsen, Kjeld; Brunø, Thomas Ditlev; Jørgensen, Kaj Asbjørn

    2014-01-01

    A recent survey has indicated that 17 % of companies have ceased mass customizing less than 1 year after initiating the effort. This paper presents measurement for a company’s mass customization performance, utilizing metrics within the three fundamental capabilities: robust process design, choice...... navigation, and solution space development. A mass customizer when assessing performance with these metrics can identify within which areas improvement would increase competitiveness the most and enable more efficient transition to mass customization....

  15. Reliability and Correlation of Static and Dynamic Foot Arch Measurement in a Healthy Pediatric Population.

    Science.gov (United States)

    Scholz, Timo; Zech, Astrid; Wegscheider, Karl; Lezius, Susanne; Braumann, Klaus-Michael; Sehner, Susanne; Hollander, Karsten

    2017-09-01

    Measurement of the medial longitudinal foot arch in children is a controversial topic, as there are many different methods without a definite standard procedure. The purpose of this study was to 1) investigate intraday and interrater reliability regarding dynamic arch index and static arch height, 2) explore the correlation between both arch indices, and 3) examine the variation of the medial longitudinal arch at two different times of the day. Eighty-six children (mean ± SD age, 8.9 ± 1.9 years) participated in the study. Dynamic footprint data were captured with a pedobarographic platform. For static arch measurements, a specially constructed caliper was used to assess heel-to-toe length and dorsum height. A mixed model was established to determine reliability and variation. Reliability was found to be excellent for the static arch height index in sitting (intraday, 0.90; interrater, 0.80) and standing positions (0.88 and 0.85) and for the dynamic arch index (both 1.00). There was poor correlation between static and dynamic assessment of the medial longitudinal arch (standing dynamic arch index, r = -0.138; sitting dynamic arch index, r = -0.070). Static measurements were found to be significantly influenced by the time of day (P body mass index (P mind. For clinical purposes, static and dynamic arch data should be interpreted separately.

  16. Measuring Passenger Travel Time Reliability Using Smart Card Data

    NARCIS (Netherlands)

    Bagherian, M.; Cats, O.; van Oort, N.; Hickman, M

    2016-01-01

    Service reliability is a key performance measure for transit agencies in increasing their service quality and thus ridership. Conventional reliability metrics are established based on vehicle movements and thus do not adequately reflect passenger’s experience. In the past few years, the growing

  17. Measuring time and risk preferences: Reliability, stability, domain specificity

    NARCIS (Netherlands)

    Wölbert, E.M.; Riedl, A.M.

    2013-01-01

    To accurately predict behavior economists need reliable measures of individual time preferences and attitudes toward risk and typically need to assume stability of these characteristics over time and across decision domains. We test the reliability of two choice tasks for eliciting discount rates,

  18. A portable, automated, inexpensive mass and balance calibration system

    International Nuclear Information System (INIS)

    Maxwell, S.L. III; Clark, J.P.

    1987-01-01

    Reliable mass measurements are essential for a nuclear production facility or process control laboratory. DOE Order 5630.2 requires that traceable standards be used to calibrate and monitor equipment used for nuclear material measurements. To ensure the reliability of mass measurements and to comply with DOE traceability requirements, a portable, automated mass and balance calibration system is used at the Savannah River Plant. Automation is achieved using an EPSON HX-20 notebook computer, which can be operated via RS232C interfacing to electronic balances or function with manual data entry if computer interfacing is not feasible. This economical, comprehensive, user-friendly system has three main functions in a mass measurement control program (MMCP): balance certification, calibration of mass standards, and daily measurement of traceable standards. The balance certification program tests for accuracy, precision, sensitivity, linearity, and cornerloading versus specific requirements. The mass calibration program allows rapid calibration of inexpensive mass standards traceable to certified Class S standards. This MMCP permits daily measurement of traceable standards to monitor the reliability of balances during routine use. The automated system verifies balance calibration, stores results for future use, and provides a printed control chart of the stored data. Another feature of the system permits three different weighing routines that accommodate their need for varying degrees of reliability in routine weighing operations

  19. A portable, automated, inexpensive mass and balance calibration system

    International Nuclear Information System (INIS)

    Maxwell, S.L. III; Clark, J.P.

    1987-01-01

    Reliable mass measurements are essential for a nuclear production facility or process control laboratory. DOE Order 5630.2 requires that traceable standards be used to calibrate and monitor equipment used for nuclear material measurements. To ensure the reliability of mass measurements and to comply with DOE traceable requirements, a portable, automated mass and balance calibration system is used at the Savannah River Plant. Automation is achieved using an EPSON HX-20 notebook computer, which can be operated via RS232C interfacing to electronic balances or function with manual data entry if computer interfacing is not feasible. This economical, comprehensive, user-friendly system has three main functions in a mass measurement control program (MMCP): balance certification, calibration of mass standards, and daily measurement of traceable standards. The balance certification program tests for accuracy, precision, sensitivity, linearity, and cornerloading versus specific requirements. The mass calibration program allows rapid calibration of inexpensive mass standards traceable to certified Class S standards. This MMCP permits daily measurement of traceable standards to monitor the reliability of balances during routine use. The automated system verifies balance calibration, stores results for future use, and provides a printed control chart of the stored data. Another feature of the system permits three different weighing routines that accommodate our need for varying degrees of reliability in routine weighing operations. 1 ref

  20. Automated reliability assessment for spectroscopic redshift measurements

    Science.gov (United States)

    Jamal, S.; Le Brun, V.; Le Fèvre, O.; Vibert, D.; Schmitt, A.; Surace, C.; Copin, Y.; Garilli, B.; Moresco, M.; Pozzetti, L.

    2018-03-01

    Context. Future large-scale surveys, such as the ESA Euclid mission, will produce a large set of galaxy redshifts (≥106) that will require fully automated data-processing pipelines to analyze the data, extract crucial information and ensure that all requirements are met. A fundamental element in these pipelines is to associate to each galaxy redshift measurement a quality, or reliability, estimate. Aim. In this work, we introduce a new approach to automate the spectroscopic redshift reliability assessment based on machine learning (ML) and characteristics of the redshift probability density function. Methods: We propose to rephrase the spectroscopic redshift estimation into a Bayesian framework, in order to incorporate all sources of information and uncertainties related to the redshift estimation process and produce a redshift posterior probability density function (PDF). To automate the assessment of a reliability flag, we exploit key features in the redshift posterior PDF and machine learning algorithms. Results: As a working example, public data from the VIMOS VLT Deep Survey is exploited to present and test this new methodology. We first tried to reproduce the existing reliability flags using supervised classification in order to describe different types of redshift PDFs, but due to the subjective definition of these flags (classification accuracy 58%), we soon opted for a new homogeneous partitioning of the data into distinct clusters via unsupervised classification. After assessing the accuracy of the new clusters via resubstitution and test predictions (classification accuracy 98%), we projected unlabeled data from preliminary mock simulations for the Euclid space mission into this mapping to predict their redshift reliability labels. Conclusions: Through the development of a methodology in which a system can build its own experience to assess the quality of a parameter, we are able to set a preliminary basis of an automated reliability assessment for

  1. Precise atomic mass measurements by deflection mass spectrometry

    CERN Document Server

    Barber, R C

    2003-01-01

    Since its inception nearly 90 years ago by J.J. Thomson, the precise determination of atomic masses by the classical technique of deflecting charged particles in electric and magnetic fields has provided a large body of data on naturally occurring nuclides. Currently, such measurements on stable nuclides have frequently achieved a precision of better than two parts in 10 sup 9 of the mass. A review of the technique, together with a brief summary of the important historical developments in the field of precise atomic mass measurements, will be given. The more recent contributions to this field by the deflection mass spectrometer at the University of Manitoba will be provided as illustrations of the culmination of the techniques used and the applications that have been studied. A brief comparison between this and newer techniques using Penning traps will be presented.

  2. Technology on precision measurement of mass

    International Nuclear Information System (INIS)

    2005-10-01

    This book mentions mass and scales about technology for precision measurement, which deal with how to measure mass with scale. So it describes the basic things of mass and scales. It includes translated book of international standard OIML with demand of measurement and technology and form for test report and international original standard OIML with metrological and technical requirements and test report format.

  3. A comparison of manual anthropometric measurements with Kinect-based scanned measurements in terms of precision and reliability.

    Science.gov (United States)

    Bragança, Sara; Arezes, Pedro; Carvalho, Miguel; Ashdown, Susan P; Castellucci, Ignacio; Leão, Celina

    2018-01-01

    Collecting anthropometric data for real-life applications demands a high degree of precision and reliability. It is important to test new equipment that will be used for data collectionOBJECTIVE:Compare two anthropometric data gathering techniques - manual methods and a Kinect-based 3D body scanner - to understand which of them gives more precise and reliable results. The data was collected using a measuring tape and a Kinect-based 3D body scanner. It was evaluated in terms of precision by considering the regular and relative Technical Error of Measurement and in terms of reliability by using the Intraclass Correlation Coefficient, Reliability Coefficient, Standard Error of Measurement and Coefficient of Variation. The results obtained showed that both methods presented better results for reliability than for precision. Both methods showed relatively good results for these two variables, however, manual methods had better results for some body measurements. Despite being considered sufficiently precise and reliable for certain applications (e.g. apparel industry), the 3D scanner tested showed, for almost every anthropometric measurement, a different result than the manual technique. Many companies design their products based on data obtained from 3D scanners, hence, understanding the precision and reliability of the equipment used is essential to obtain feasible results.

  4. Reliability of impedance cardiography in measuring central haemodynamics

    DEFF Research Database (Denmark)

    Mehlsen, J; Bonde, J; Stadeager, C

    1991-01-01

    The purpose of the study described here was to investigate the reliability of impedance cardiography (IC) in measuring cardiac output (CO) and central blood volume. Absolute values and changes in these variables obtained by impedance cardiography and by isotope- or thermodilution techniques were...... suitable for repeated measurements in studies on the haemodynamic effects of physiological or pharmacological intervention. Impedance cardiography is sufficiently reliable for comparison of absolute values of CO between different groups of patients. We cannot recommend impedance cardiography...... healthy subjects and in 25 unmedicated patients with ischaemic heart disease. We obtained significant correlations between absolute values (y = 0.68x + 1.48) and changes (y = 1.00x + 0.0003) in CO measured by IC and isotope- or thermodilution. IC significantly overestimated absolute values of CO (P less...

  5. Handbook of mass measurement

    CERN Document Server

    Jones, Frank E

    2002-01-01

    "How much does it weigh?" seems a simple question. To scientists and engineers, however, the answer is far from simple, and determining the answer demands consideration of an almost overwhelming number of factors.With an intriguing blend of history, fundamentals, and technical details, the Handbook of Mass Measurement sets forth the details of achieving the highest precision in mass measurements. It covers the whole field, from the development, calibration, and maintenance of mass standards to detailed accounts of weighing designs, balances, and uncertainty. It addresses the entire measurement process and provides in-depth examinations of the various factors that introduce error.Much of the material is the authors'' own work and some of it is published here for the first time. Jones and Schoonover are both highly regarded veterans of the U.S. National Institute of Standards and Technology. With this handbook, they have provided a service and resource vital to anyone involved not only in the determination of m...

  6. Evidence for Broad-Line Region Outflows and Their Impact on Black Hole Mass Measurements

    DEFF Research Database (Denmark)

    Denney, K. D.; Assef, R. J.; Horne, K.

    2012-01-01

    could not be fully and accurately interpreted from the 1D velocity-resolved reverberation signal. From the VDM, an outflow component to the emission remains possible but appears to be in addition to an underlying, disk-like BLR structure consistent in size with the measured reverberation lag. The black...... hole (BH) mass derived from this data is therefore secure from any uncertainties possibly derived from gravitationally unbound gas contributing to the emission. Additionally, we demonstrate that BLR emission from the C IV ¿1549 broad emission line can reliably be used as a virial BH mass estimator...

  7. Reliability of EEG Interactions Differs between Measures and Is Specific for Neurological Diseases

    Directory of Open Access Journals (Sweden)

    Yvonne Höller

    2017-07-01

    Full Text Available Alterations of interaction (connectivity of the EEG reflect pathological processes in patients with neurologic disorders. Nevertheless, it is questionable whether these patterns are reliable over time in different measures of interaction and whether this reliability of the measures is the same across different patient populations. In order to address this topic we examined 22 patients with mild cognitive impairment, five patients with subjective cognitive complaints, six patients with right-lateralized temporal lobe epilepsy, seven patients with left lateralized temporal lobe epilepsy, and 20 healthy controls. We calculated 14 measures of interaction from two EEG-recordings separated by 2 weeks. In order to characterize test-retest reliability, we correlated these measures for each group and compared the correlations between measures and between groups. We found that both measures of interaction as well as groups differed from each other in terms of reliability. The strongest correlation coefficients were found for spectrum, coherence, and full frequency directed transfer function (average rho > 0.9. In the delta (2–4 Hz range, reliability was lower for mild cognitive impairment compared to healthy controls and left lateralized temporal lobe epilepsy. In the beta (13–30 Hz, gamma (31–80 Hz, and high gamma (81–125 Hz frequency ranges we found decreased reliability in subjective cognitive complaints compared to mild cognitive impairment. In the gamma and high gamma range we found increased reliability in left lateralized temporal lobe epilepsy patients compared to healthy controls. Our results emphasize the importance of documenting reliability of measures of interaction, which may vary considerably between measures, but also between patient populations. We suggest that studies claiming clinical usefulness of measures of interaction should provide information on the reliability of the results. In addition, differences between patient

  8. Inkjet metrology: high-accuracy mass measurements of microdroplets produced by a drop-on-demand dispenser.

    Science.gov (United States)

    Verkouteren, R Michael; Verkouteren, Jennifer R

    2009-10-15

    We describe gravimetric methods for measuring the mass of droplets generated by a drop-on-demand (DOD) microdispenser. Droplets are deposited, either continuously at a known frequency or as a burst of known number, into a cylinder positioned on a submicrogram balance. Mass measurements are acquired precisely by computer, and results are corrected for evaporation. Capabilities are demonstrated using isobutyl alcohol droplets. For ejection rates greater than 100 Hz, the repeatability of droplet mass measurements was 0.2%, while the combined relative standard uncertainty (u(c)) was 0.9%. When bursts of droplets were dispensed, the limit of quantitation was 72 microg (1490 droplets) with u(c) = 1.0%. Individual droplet size in a burst was evaluated by high-speed videography. Diameters were consistent from the tenth droplet onward, and the mass of an individual droplet was best estimated by the average droplet mass with a combined uncertainty of about 1%. Diameters of the first several droplets were anomalous, but their contribution was accounted for when dispensing bursts. Above the limits of quantitation, the gravimetric methods provided statistically equivalent results and permit detailed study of operational factors that influence droplet mass during dispensing, including the development of reliable microassays and standard materials using DOD technologies.

  9. Reliability and relationship of radiographic measurements in hallux valgus.

    Science.gov (United States)

    Lee, Kyoung Min; Ahn, Soyeon; Chung, Chin Youb; Sung, Ki Hyuk; Park, Moon Seok

    2012-09-01

    Although various radiographic measurements have been developed and used for evaluating hallux valgus, not all are universally believed to be necessary and their relationships have not been clearly established. Determining which are related could provide some insight into which might be useful and which would not. We investigated the reliability of eight radiographic measurements used to evaluate hallux valgus, and determined which were correlated and which predicted the hallux valgus angle. We determined eight radiographic indices for 732 patients (mean age, 51 years; SD, 17 years; 107 males and 625 females) with hallux valgus: hallux valgus angle, intermetatarsal angle, hallux interphalangeal angle, distal metatarsal articular angle, proximal phalangeal articular angle, simplified metatarsus adductus angle, first metatarsal protrusion distance, and sesamoid rotation angle. Intraobserver and interobserver reliabilities of each radiographic measurement were analyzed on 36 feet from 36 randomly selected patients. Correlations among the radiographic measurements were analyzed. Radiographic measurements predicting hallux valgus angle were evaluated using multiple regression analysis. Hallux valgus angle had the highest reliability, whereas the distal metatarsal articular angle and simplified metatarsus adductus angle had the lowest. Distal metatarsal articular angle, intermetatarsal angle, and sesamoid rotation angle had the highest correlations with hallux valgus angle. Distal metatarsal articular angle correlated with sesamoid rotation angle. The intermetatarsal angle, interphalangeal angle, distal metatarsal articular angle, first metatarsal protrusion distance, sesamoid rotation angle, and metatarsus adductus angle predicted the hallux valgus angle. We suggest using hallux valgus angle, intermetatarsal angle, interphalangeal angle, sesamoid rotation angle, and first metatarsal protrusion distance considering their reliability and prediction of the deformity.

  10. Radiographic measurement reliability of lumbar lordosis in ankylosing spondylitis.

    Science.gov (United States)

    Lee, Jung Sub; Goh, Tae Sik; Park, Shi Hwan; Lee, Hong Seok; Suh, Kuen Tak

    2013-04-01

    Intraobserver and interobserver reliabilities of the several different methods to measure lumbar lordosis have been reported. However, it has not been studied sofar in patients with ankylosing spondylitis (AS). We evaluated the inter and intraobserver reliabilities of six specific measures of global lumbar lordosis in patients with AS. Ninety-one consecutive patients with AS who met the most recently modified New York criteria were enrolled and underwent anteroposterior and lateral radiographs of whole spine. The radiographs were divided into non-ankylosis (no bony bridge in the lumbar spine), incomplete ankylosis (lumbar spines were partially connected by bony bridge) and complete ankylosis groups to evaluate the reliability of the Cobb L1-S1, Cobb L1-L5, centroid, posterior tangent L1-S1, posterior tangent L1-L5, and TRALL methods. The radiographs were composed of 39 non-ankylosis, 27 incomplete ankylosis and 25 complete ankylosis. Intra- and inter-class correlation coefficients (ICCs) of all six methods were generally high. The ICCs were all ≥0.77 (excellent) for the six radiographic methods in the combined group. However, a comparison of the ICCs, 95 % confidence intervals and mean absolute difference (MAD) between groups with varying degrees of ankylosis showed that the reliability of the lordosis measurements decreased in proportion to the severity of ankylosis. The Cobb L1-S1, Cobb L1-L5 and posterior tangent L1-S1 method demonstrated higher ICCs for both inter and intraobserver comparisons and the other methods showed lower ICCs in all groups. The intraobserver MAD was similar in the Cobb L1-S1 and Cobb L1-L5 (2.7°-4.3°), but the other methods showed higher intraobserver MAD. Interobserver MAD of Cobb L1-L5 only showed low in all group. These results are the first to provide a reliability analysis of different global lumbar lordosis measurement methods in AS. The findings in this study demonstrated that the Cobb L1-L5 method is reliable for measuring

  11. RELIABILITY OF ANKLE-FOOT MORPHOLOGY, MOBILITY, STRENGTH, AND MOTOR PERFORMANCE MEASURES.

    Science.gov (United States)

    Fraser, John J; Koldenhoven, Rachel M; Saliba, Susan A; Hertel, Jay

    2017-12-01

    Assessment of foot posture, morphology, intersegmental mobility, strength and motor control of the ankle-foot complex are commonly used clinically, but measurement properties of many assessments are unclear. To determine test-retest and inter-rater reliability, standard error of measurement, and minimal detectable change of morphology, joint excursion and play, strength, and motor control of the ankle-foot complex. Reliability study. 24 healthy, recreationally-active young adults without history of ankle-foot injury were assessed by two clinicians on two occasions, three to ten days apart. Measurement properties were assessed for foot morphology (foot posture index, total and truncated length, width, arch height), joint excursion (weight-bearing dorsiflexion, rearfoot and hallux goniometry, forefoot inclinometry, 1 st metatarsal displacement) and joint play, strength (handheld dynamometry), and motor control rating during intrinsic foot muscle (IFM) exercises. Clinician order was randomized using a Latin Square. The clinicians performed independent examinations and did not confer on the findings for the duration of the study. Test-retest and inter-tester reliability and agreement was assessed using intraclass correlation coefficients (ICC 2,k ) and weighted kappa ( K w ). Test-retest reliability ICC were as follows: morphology: .80-1.00, joint excursion: .58-.97, joint play: -.67-.84, strength: .67-.92, IFM motor rating: K W -.01-.71. Inter-rater reliability ICC were as follows: morphology: .81-1.00, joint excursion: .32-.97, joint play: -1.06-1.00, strength: .53-.90, and IFM motor rating: K w .02-.56. Measures of ankle-foot posture, morphology, joint excursion, and strength demonstrated fair to excellent test-retest and inter-rater reliability. Test-retest reliability for rating of perceived difficulty and motor performance was good to excellent for short-foot, toe-spread-out, and hallux exercises and poor to fair for lesser toe extension. Joint play measures had

  12. Reliability of cervical lordosis measurement techniques on long-cassette radiographs.

    Science.gov (United States)

    Janusz, Piotr; Tyrakowski, Marcin; Yu, Hailong; Siemionow, Kris

    2016-11-01

    Lateral radiographs are commonly used to assess cervical sagittal alignment. Three assessment methods have been described and are commonly utilized in clinical practice. These methods are described for perfect lateral cervical radiographs, however in everyday practice radiograph quality varies. The aim of this study was to compare the reliability and reproducibility of 3 cervical lordosis (CL) measurement methods. Forty-four standing lateral radiographs were randomly chosen from a lateral long-cassette radiograph database. Measurements of CL were performed with: Cobb method C2-C7 (CM), C2-C7 posterior tangent method (PTM), sum of posterior tangent method for each segment (SPTM). Three independent orthopaedic surgeons measured CL using the three methods on 44 lateral radiographs. One researcher used the three methods to measured CL three times at 4-week time intervals. Agreement between the methods as well as their intra- and interobserver reliability were tested and quantified by intraclass correlation coefficient (ICC) and median error for a single measurement (SEM). ICC of 0.75 or more reflected an excellent agreement/reliability. The results were compared with repeated ANOVA test, with p  0.05). All three methods appeared to be highly reliable. Although, high agreement between all measurement methods was shown, we do not recommend using Cobb measurement method interchangeably with PTM or SPTM within a single study as this could lead to error, whereas, such a comparison between tangent methods can be considered.

  13. Measuring reliability under epistemic uncertainty: Review on non-probabilistic reliability metrics

    Directory of Open Access Journals (Sweden)

    Kang Rui

    2016-06-01

    Full Text Available In this paper, a systematic review of non-probabilistic reliability metrics is conducted to assist the selection of appropriate reliability metrics to model the influence of epistemic uncertainty. Five frequently used non-probabilistic reliability metrics are critically reviewed, i.e., evidence-theory-based reliability metrics, interval-analysis-based reliability metrics, fuzzy-interval-analysis-based reliability metrics, possibility-theory-based reliability metrics (posbist reliability and uncertainty-theory-based reliability metrics (belief reliability. It is pointed out that a qualified reliability metric that is able to consider the effect of epistemic uncertainty needs to (1 compensate the conservatism in the estimations of the component-level reliability metrics caused by epistemic uncertainty, and (2 satisfy the duality axiom, otherwise it might lead to paradoxical and confusing results in engineering applications. The five commonly used non-probabilistic reliability metrics are compared in terms of these two properties, and the comparison can serve as a basis for the selection of the appropriate reliability metrics.

  14. Top quark mass measurement in dilepton channel

    International Nuclear Information System (INIS)

    Lysak, R.

    2007-01-01

    In this work, we measured the top quark mass in tt'-' events produced in pp'-' interactions at the center-of-mass energy 1.96 TeV using CDF detector. We used dilepton in tt'-' events where both W bosons from top quarks are decaying into leptons. The data sample corresponds to 340 pb -1 . We found there 33 tt'-' candidates while expecting 10.5 ± 1.9 background events. In the measurement, we reconstruct one, representative mass for each event using the assumption about longitudinal momentum of in tt'-' system, in order to be able to kinematically solve the under-constrained system. The mass distributions (templates) are created for simulated signal and background events. Templates are parametrized in order to obtain smooth probability density functions. Likelihood maximization which includes these parametrized templates is then performed on reconstructed masses obtained from data sample in order to obtain final top quark mass estimate. The result of applying this procedure on data events is top quark mass estimate 169.5 +7. 7 - 7.2 (stat.) ± 4.0(syst.) GeV/c 2 for 30 out of 33 candidates, where the solution for top quark mass was found. This measurement was a part of first top quark mass measurement in dilepton channel at CDF in Run II. The top quark mass measured here is consistent with the CDF measurement in dilepton channel from Run I M top = 167.4 ± 10.3(stat.) ± 4.8(syst.) GeV/c 2 . Moreover, the combined result of four top quark mass measurements in dilepton channel from Run II (one of these four measurements is our measurement) M top = 167.9 ± 5.2(stat.) ± 3.7(syst.) GeV/c 2 significantly (by ∼ 40%) improved the precision of top quark mass determination from Run I. It should be also noted, that this combined result is consistent with measurement obtained in 'lepton+jets' channel at CDF in Run II (M top = 173.5 +3.9 -3.8 GeV/c 2 ). So, we don't have yet any indication about new physics beyond the Standard Model. My main contribution in this analysis was

  15. Geoelectrical Measurement of Multi-Scale Mass Transfer Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Day-Lewis, Frederick; Singha, Kamini; Haggerty, Roy; Johnson, Tim; Binley, Andrew; Lane, John

    2014-01-16

    -part research plan involving (1) development of computer codes and techniques to estimate mass-transfer parameters from time-lapse electrical data; (2) bench-scale experiments on synthetic materials and materials from cores from the Hanford 300 Area; and (3) field demonstration experiments at the DOE’s Hanford 300 Area. In a synergistic add-on to our workplan, we analyzed data from field experiments performed at the DOE Naturita Site under a separate DOE SBR grant, on which PI Day-Lewis served as co-PI. Techniques developed for application to Hanford datasets also were applied to data from Naturita. 1. Introduction The Department of Energy (DOE) faces enormous scientific and engineering challenges associated with the remediation of legacy contamination at former nuclear weapons production facilities. Selection, design and optimization of appropriate site remedies (e.g., pump-and-treat, biostimulation, or monitored natural attenuation) requires reliable predictive models of radionuclide fate and transport; however, our current modeling capabilities are limited by an incomplete understanding of multi-scale mass transfer—its rates, scales, and the heterogeneity of controlling parameters. At many DOE sites, long “tailing” behavior, concentration rebound, and slower-than-expected cleanup are observed; these observations are all consistent with multi-scale mass transfer [Haggerty and Gorelick, 1995; Haggerty et al., 2000; 2004], which renders pump-and-treat remediation and biotransformation inefficient and slow [Haggerty and Gorelick, 1994; Harvey et al., 1994; Wilson, 1997]. Despite the importance of mass transfer, there are significant uncertainties associated with controlling parameters, and the prevalence of mass transfer remains a point of debate [e.g., Hill et al., 2006; Molz et al., 2006] for lack of experimental methods to verify and measure it in situ or independently of tracer breakthrough. There is a critical need for new field-experimental techniques to

  16. Validating the absolute reliability of a fat free mass estimate equation in hemodialysis patients using near-infrared spectroscopy.

    Science.gov (United States)

    Kono, Kenichi; Nishida, Yusuke; Moriyama, Yoshihumi; Taoka, Masahiro; Sato, Takashi

    2015-06-01

    The assessment of nutritional states using fat free mass (FFM) measured with near-infrared spectroscopy (NIRS) is clinically useful. This measurement should incorporate the patient's post-dialysis weight ("dry weight"), in order to exclude the effects of any change in water mass. We therefore used NIRS to investigate the regression, independent variables, and absolute reliability of FFM in dry weight. The study included 47 outpatients from the hemodialysis unit. Body weight was measured before dialysis, and FFM was measured using NIRS before and after dialysis treatment. Multiple regression analysis was used to estimate the FFM in dry weight as the dependent variable. The measured FFM before dialysis treatment (Mw-FFM), and the difference between measured and dry weight (Mw-Dw) were independent variables. We performed Bland-Altman analysis to detect errors between the statistically estimated FFM and the measured FFM after dialysis treatment. The multiple regression equation to estimate the FFM in dry weight was: Dw-FFM = 0.038 + (0.984 × Mw-FFM) + (-0.571 × [Mw-Dw]); R(2)  = 0.99). There was no systematic bias between the estimated and the measured values of FFM in dry weight. Using NIRS, FFM in dry weight can be calculated by an equation including FFM in measured weight and the difference between the measured weight and the dry weight. © 2015 The Authors. Therapeutic Apheresis and Dialysis © 2015 International Society for Apheresis.

  17. Inter-Rater Reliability of Cyclotorsion Measurements Using Fundus Photography.

    Science.gov (United States)

    Dysli, Muriel; Kanku, Madeleine; Traber, Ghislaine L

    2018-04-01

    The foveo-papillary angle (FPA) on fundus photographs is the accepted standard for the measurement of ocular cyclotorsion. We assessed the inter-rater reliability of this method in healthy subjects and in patients with trochlear nerve palsies. In this methodological study, fundus photographs of healthy subjects and of patients with trochlear nerve palsies were made with a fundus camera (Zeiss Fundus Camera FF 450 plus, Jena, Germany). Three independent observers measured the FPA on the fundus photographs of all subjects in synedra View (synedra View 16, Version 16.0.0.11, Innsbruck, Austria). One hundred and four eyes of 52 subjects (26 healthy controls and 26 patients) were assessed. The mean FPA of the healthy controls was 5.80 degrees (°) [± 0.44 standard error of the mean (SEM)] compared to 11.55° (± 0.80 SEM) for patients with trochlear nerve palsies. The inter-rater reliability of all measured FPAs showed an intraclass correlation coefficient (ICC) of 0.98 (95% CI 0.97 - 0.98). The inter-rater reliability of objective cyclotorsion measurements using fundus photographs was very high. Georg Thieme Verlag KG Stuttgart · New York.

  18. Reliability of radiographic measurements for acute distal radius fractures

    International Nuclear Information System (INIS)

    Watson, Narelle J.; Asadollahi, Saeed; Parrish, Frank; Ridgway, Jacqueline; Tran, Phong; Keating, Jennifer L.

    2016-01-01

    The management of distal radial fractures is guided by the interpretation of radiographic findings. The aim of this investigation was to determine the intra- and inter-observer reliability of eight traditionally reported anatomic radiographic parameters in adults with an acute distal radius fracture. Five observers participated. All were routinely involved in making treatment decisions based on distal radius fracture radiographs. Observers performed independent repeated measurements on 30 radiographs for eight anatomical parameters: dorsal shift (mm), intra-articular gap (mm), intra-articular step (mm), palmar tilt (degrees), radial angle (degrees), radial height (mm), radial shift (mm), ulnar variance (mm). Intraclass correlation coefficients (ICCs) and the magnitude of retest errors were calculated. Measurement reliability was summarised as high (ICC > 0.80), moderate (0.60–0.80) or low (<0.60). Intra-observer reliability was high for dorsal shift and palmar tilt; moderate for radial angle, radial height, ulnar variance and radial shift; and low for intra-articular gap and step. Inter-observer reliability was high for palmar tilt; moderate for dorsal shift, ulnar variance, radial angle and radial height; and low for radial shift, intra-articular gap and step. Error magnitude (95 % confidence interval) was within 1–2 mm for intra-articular gap and step, 2–4 mm for ulnar variance, 4–6 mm for radial shift, dorsal shift and radial height, and 6–8° for radial angle and palmar tilt. Based on previous reports of critical values for palmar tilt, ulnar variance and radial angle, error margins appear small enough for measurements to be useful in guiding treatment decisions. Our findings indicate that clinicians cannot reliably measure values ≤1 mm for intra-articular gap and step when interpreting radiographic parameters using the standardised methods investigated in this study. As a guide for treatment selection, palmar tilt, ulnar variance and radial angle

  19. Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.

    Science.gov (United States)

    Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti

    2017-06-28

    The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.

  20. Insights from Synthetic Star-forming Regions. II. Verifying Dust Surface Density, Dust Temperature, and Gas Mass Measurements With Modified Blackbody Fitting

    Energy Technology Data Exchange (ETDEWEB)

    Koepferl, Christine M.; Robitaille, Thomas P. [Max Planck Institute for Astronomy, Königstuhl 17, D-69117 Heidelberg (Germany); Dale, James E., E-mail: koepferl@usm.lmu.de [University Observatory Munich, Scheinerstr. 1, D-81679 Munich (Germany)

    2017-11-01

    We use a large data set of realistic synthetic observations (produced in Paper I of this series) to assess how observational techniques affect the measurement physical properties of star-forming regions. In this part of the series (Paper II), we explore the reliability of the measured total gas mass, dust surface density and dust temperature maps derived from modified blackbody fitting of synthetic Herschel observations. We find from our pixel-by-pixel analysis of the measured dust surface density and dust temperature a worrisome error spread especially close to star formation sites and low-density regions, where for those “contaminated” pixels the surface densities can be under/overestimated by up to three orders of magnitude. In light of this, we recommend to treat the pixel-based results from this technique with caution in regions with active star formation. In regions of high background typical in the inner Galactic plane, we are not able to recover reliable surface density maps of individual synthetic regions, since low-mass regions are lost in the far-infrared background. When measuring the total gas mass of regions in moderate background, we find that modified blackbody fitting works well (absolute error: + 9%; −13%) up to 10 kpc distance (errors increase with distance). Commonly, the initial images are convolved to the largest common beam-size, which smears contaminated pixels over large areas. The resulting information loss makes this commonly used technique less verifiable as now χ {sup 2} values cannot be used as a quality indicator of a fitted pixel. Our control measurements of the total gas mass (without the step of convolution to the largest common beam size) produce similar results (absolute error: +20%; −7%) while having much lower median errors especially for the high-mass stellar feedback phase. In upcoming papers (Paper III; Paper IV) of this series we test the reliability of measured star formation rate with direct and indirect

  1. Insights from Synthetic Star-forming Regions. II. Verifying Dust Surface Density, Dust Temperature, and Gas Mass Measurements with Modified Blackbody Fitting

    Science.gov (United States)

    Koepferl, Christine M.; Robitaille, Thomas P.; Dale, James E.

    2017-11-01

    We use a large data set of realistic synthetic observations (produced in Paper I of this series) to assess how observational techniques affect the measurement physical properties of star-forming regions. In this part of the series (Paper II), we explore the reliability of the measured total gas mass, dust surface density and dust temperature maps derived from modified blackbody fitting of synthetic Herschel observations. We find from our pixel-by-pixel analysis of the measured dust surface density and dust temperature a worrisome error spread especially close to star formation sites and low-density regions, where for those “contaminated” pixels the surface densities can be under/overestimated by up to three orders of magnitude. In light of this, we recommend to treat the pixel-based results from this technique with caution in regions with active star formation. In regions of high background typical in the inner Galactic plane, we are not able to recover reliable surface density maps of individual synthetic regions, since low-mass regions are lost in the far-infrared background. When measuring the total gas mass of regions in moderate background, we find that modified blackbody fitting works well (absolute error: + 9%; -13%) up to 10 kpc distance (errors increase with distance). Commonly, the initial images are convolved to the largest common beam-size, which smears contaminated pixels over large areas. The resulting information loss makes this commonly used technique less verifiable as now χ 2 values cannot be used as a quality indicator of a fitted pixel. Our control measurements of the total gas mass (without the step of convolution to the largest common beam size) produce similar results (absolute error: +20%; -7%) while having much lower median errors especially for the high-mass stellar feedback phase. In upcoming papers (Paper III; Paper IV) of this series we test the reliability of measured star formation rate with direct and indirect techniques.

  2. Reliability of footprint geometric and plantar loading measurements in children using the Emed(®) M system.

    Science.gov (United States)

    Tong, Jasper W K; Kong, Pui W

    2013-06-01

    This study investigated the between-day reliability of footprint geometric and plantar loading measurements on children utilising the Emed(®) M pressure measurement device. Bilateral footprints (static and dynamic) and foot loading measurements using the two-step gait method were collected on 21 children two days apart (age = 9.9 ± 1.8 years; mass = 34.6 ± 8.9 kg; height = 1.38 ± 0.12 m). Static and dynamic footprint geometric (lengths, widths and angles) and dynamic loading (pressures, forces, contact areas and contact time) parameters were compared. Intraclass correlation coefficients of static geometric parameters were varied (0.19-0.96), while superior results were achieved with dynamic geometric (0.66-0.98) and loading variables (0.52-0.94), with the exception of left contact time (0.37). Standard error of measurement recorded small absolute disparity for all geometric (length = 0.1-0.3 cm; arch index = 0.00-0.01; subarch angle = 0.6-6.2°; left/right foot progression angle = 0.5°/0.7°) and loading (peak pressure = 2.3-16.2 kPa; maximum force = 0.3-3.0%; total contact area = 0.28-0.49 cm(2); % contact area = 0.1-0.6%; contact time = 32-79 ms) variables. Coefficient of variation displayed widest spread for static geometry (1.1-27.6%) followed by dynamic geometry (0.8-22.5%) and smallest spread for loading (1.3-16.8%) parameters. Limits of agreement (95%) were narrower in dynamic than static geometric parameters. Overall, the reliability of most dynamic geometric and loading parameters was good and excellent. Static electronic footprint measurements on children are not recommended due to their light body mass which results in incomplete footprints. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. The reliability of in-home measures of height and weight in large cohort studies: Evidence from Add Health

    Directory of Open Access Journals (Sweden)

    Jon Hussey

    2015-05-01

    Full Text Available Background: With the emergence of obesity as a global health issue, an increasing number of major demographic surveys are collecting measured anthropometric data. Yet little is known about the characteristics and reliability of these data. Objective: We evaluate the accuracy and reliability of anthropometric data collected in the home during Wave IV of the National Longitudinal Study of Adolescent to Adult Health (Add Health, compare our estimates to national standard, clinic-based estimates from the National Health and Nutrition Examination Survey (NHANES and, using both sources, provide a detailed anthropometric description of young adults in the United States. Methods: The reliability of Add Health in-home anthropometric measures was estimated from repeat examinations of a random subsample of study participants. A digit preference analysis evaluated the quality of anthropometric data recorded by field interviewers. The adjusted odds of obesity and central obesity in Add Health vs. NHANES were estimated with logistic regression. Results: Short-term reliabilities of in-home measures of height, weight, waist and arm circumference - as well as derived body mass index (BMI, kg/m2 - were excellent. Prevalence of obesity (37Š vs. 29Š and central obesity (47Š vs. 38Š was higher in Add Health than in NHANES, while socio-demographic patterns of obesity and central obesity were comparable in the two studies. Conclusions: Properly trained non-medical field interviewers can collect reliable anthropometric data in a nationwide, home visit study. This national cohort of young adults in the United States faces a high risk of early-onset chronic disease and premature mortality.

  4. Comparison of reliability of lateral cephalogram and computed ...

    African Journals Online (AJOL)

    2014-05-07

    May 7, 2014 ... measurements acquired from both the modalities are reliable and reproducible, but .... paint on all the slice of the image stack in the axial plane of ..... between body mass index, age and upper airway measurements in snorers.

  5. Measurement-based reliability/performability models

    Science.gov (United States)

    Hsueh, Mei-Chen

    1987-01-01

    Measurement-based models based on real error-data collected on a multiprocessor system are described. Model development from the raw error-data to the estimation of cumulative reward is also described. A workload/reliability model is developed based on low-level error and resource usage data collected on an IBM 3081 system during its normal operation in order to evaluate the resource usage/error/recovery process in a large mainframe system. Thus, both normal and erroneous behavior of the system are modeled. The results provide an understanding of the different types of errors and recovery processes. The measured data show that the holding times in key operational and error states are not simple exponentials and that a semi-Markov process is necessary to model the system behavior. A sensitivity analysis is performed to investigate the significance of using a semi-Markov process, as opposed to a Markov process, to model the measured system.

  6. Nanoscale deformation measurements for reliability assessment of material interfaces

    Science.gov (United States)

    Keller, Jürgen; Gollhardt, Astrid; Vogel, Dietmar; Michel, Bernd

    2006-03-01

    With the development and application of micro/nano electronic mechanical systems (MEMS, NEMS) for a variety of market segments new reliability issues will arise. The understanding of material interfaces is the key for a successful design for reliability of MEMS/NEMS and sensor systems. Furthermore in the field of BIOMEMS newly developed advanced materials and well known engineering materials are combined despite of fully developed reliability concepts for such devices and components. In addition the increasing interface-to volume ratio in highly integrated systems and nanoparticle filled materials are challenges for experimental reliability evaluation. New strategies for reliability assessment on the submicron scale are essential to fulfil the needs of future devices. In this paper a nanoscale resolution experimental method for the measurement of thermo-mechanical deformation at material interfaces is introduced. The determination of displacement fields is based on scanning probe microscopy (SPM) data. In-situ SPM scans of the analyzed object (i.e. material interface) are carried out at different thermo-mechanical load states. The obtained images are compared by grayscale cross correlation algorithms. This allows the tracking of local image patterns of the analyzed surface structure. The measurement results are full-field displacement fields with nanometer resolution. With the obtained data the mixed mode type of loading at material interfaces can be analyzed with highest resolution for future needs in micro system and nanotechnology.

  7. Precision Mass Measurement of Argon Isotopes

    CERN Multimedia

    Lunney, D

    2002-01-01

    % IS388\\\\ \\\\ A precision mass measurement of the neutron-deficient isotopes $^{32,33,34}$Ar is proposed. Mass values of these isotopes are of importance for: a) a stringent test of the Isobaric-Multiplet- Mass-Equation, b) a verification of the correctness of calculated charge-dependent corrections as used in super-allowed $\\beta$- decay studies aiming at a test of the CVC hypothesis, and c) the determination of the kinematics in electron-neutrino correlation experiments searching for scalar currents in weak interaction. The measurements will be carried out with the ISOLTRAP Penning trap mass spectrometer.

  8. Relationship between body mass, lean mass, fat mass, and limb bone cross-sectional geometry: Implications for estimating body mass and physique from the skeleton.

    Science.gov (United States)

    Pomeroy, Emma; Macintosh, Alison; Wells, Jonathan C K; Cole, Tim J; Stock, Jay T

    2018-05-01

    Estimating body mass from skeletal dimensions is widely practiced, but methods for estimating its components (lean and fat mass) are poorly developed. The ability to estimate these characteristics would offer new insights into the evolution of body composition and its variation relative to past and present health. This study investigates the potential of long bone cross-sectional properties as predictors of body, lean, and fat mass. Humerus, femur and tibia midshaft cross-sectional properties were measured by peripheral quantitative computed tomography in sample of young adult women (n = 105) characterized by a range of activity levels. Body composition was estimated from bioimpedance analysis. Lean mass correlated most strongly with both upper and lower limb bone properties (r values up to 0.74), while fat mass showed weak correlations (r ≤ 0.29). Estimation equations generated from tibial midshaft properties indicated that lean mass could be estimated relatively reliably, with some improvement using logged data and including bone length in the models (minimum standard error of estimate = 8.9%). Body mass prediction was less reliable and fat mass only poorly predicted (standard errors of estimate ≥11.9% and >33%, respectively). Lean mass can be predicted more reliably than body mass from limb bone cross-sectional properties. The results highlight the potential for studying evolutionary trends in lean mass from skeletal remains, and have implications for understanding the relationship between bone morphology and body mass or composition. © 2018 The Authors. American Journal of Physical Anthropology Published by Wiley Periodicals, Inc.

  9. Is linear distance measured by panoramic radiography reliable?

    International Nuclear Information System (INIS)

    Nishikawa, Keiichi; Wakoh, Mamoru; Sano, Tsukasa; Suehiro, Atsushi; Sekine, Hideshi; Kousuge, Yuuji

    2010-01-01

    The objective of this study was to re-examine the reliability of distance measurements on clinical panoramic radiographs by comparing them with computed tomography (CT) images, from which the most accurate distance measurement is possible. Twenty pairs of images from patients examined both with panoramic radiography and CT for dental implant treatment planning in the premolar and molar regions of the mandible were used. The vertical linear distance between the alveolar crest and the closest mandibular canal was measured by three experienced oral radiologists on both images. The distances measured on panoramic radiographs were corrected for the magnification factor at the focal plane. Double-oblique cross-sectional images were used for CT. Pearson's correlation coefficient was calculated between distances obtained from both images. The paired t test was performed for statistical comparison. Error levels with the panoramic radiograph versus the CT image were also calculated. Pearson's correlation coefficient showed a significant strong linear correlation (R=0.90; p<0.01). However, the corrected value of distance measured on panoramic radiographs tended to be too small, and a significant difference was observed (p<0.05). The error level was approximately 10% (9.6±7.3%). Distance measurement on clinical panoramic radiographs is less reliable than CT images and cannot be recommended. (author)

  10. Measuring the running top-quark mass

    International Nuclear Information System (INIS)

    Langenfeld, Ulrich; Uwer, Peter

    2010-06-01

    In this contribution we discuss conceptual issues of current mass measurements performed at the Tevatron. In addition we propose an alternative method which is theoretically much cleaner and to a large extend free from the problems encountered in current measurements. In detail we discuss the direct determination of the top-quark's running mass from the cross section measurements performed at the Tevatron. (orig.)

  11. Reliability and Inequality Measures for the Weimal Distribution ...

    African Journals Online (AJOL)

    ). This article aimed at discussing both reliability and inequality measures from the Weimal distribution. The work has derived and discussed theoretically, expressions for the survival and hazard function of the Weimal distribution. The ordinary ...

  12. The construction of TRIGA-TRAP and direct high-precision Penning trap mass measurements on rare-earth elements and americium

    Energy Technology Data Exchange (ETDEWEB)

    Ketelaer, Jens

    2010-06-14

    The construction of TRIGA-TRAP and direct high-precision Penning trap mass measurements on rare-earth elements and americium: Nuclear masses are an important quantity to study nuclear structure since they reflect the sum of all nucleonic interactions. Many experimental possibilities exist to precisely measure masses, out of which the Penning trap is the tool to reach the highest precision. Moreover, absolute mass measurements can be performed using carbon, the atomic-mass standard, as a reference. The new double-Penning trap mass spectrometer TRIGA-TRAP has been installed and commissioned within this thesis work, which is the very first experimental setup of this kind located at a nuclear reactor. New technical developments have been carried out such as a reliable non-resonant laser ablation ion source for the production of carbon cluster ions and are still continued, like a non-destructive ion detection technique for single-ion measurements. Neutron-rich fission products will be available by the reactor that are important for nuclear astrophysics, especially the r-process. Prior to the on-line coupling to the reactor, TRIGA-TRAP already performed off-line mass measurements on stable and long-lived isotopes and will continue this program. The main focus within this thesis was on certain rare-earth nuclides in the well-established region of deformation around N {proportional_to} 90. Another field of interest are mass measurements on actinoids to test mass models and to provide direct links to the mass standard. Within this thesis, the mass of {sup 241}Am could be measured directly for the first time. (orig.)

  13. The construction of TRIGA-TRAP and direct high-precision Penning trap mass measurements on rare-earth elements and americium

    International Nuclear Information System (INIS)

    Ketelaer, Jens

    2010-01-01

    The construction of TRIGA-TRAP and direct high-precision Penning trap mass measurements on rare-earth elements and americium: Nuclear masses are an important quantity to study nuclear structure since they reflect the sum of all nucleonic interactions. Many experimental possibilities exist to precisely measure masses, out of which the Penning trap is the tool to reach the highest precision. Moreover, absolute mass measurements can be performed using carbon, the atomic-mass standard, as a reference. The new double-Penning trap mass spectrometer TRIGA-TRAP has been installed and commissioned within this thesis work, which is the very first experimental setup of this kind located at a nuclear reactor. New technical developments have been carried out such as a reliable non-resonant laser ablation ion source for the production of carbon cluster ions and are still continued, like a non-destructive ion detection technique for single-ion measurements. Neutron-rich fission products will be available by the reactor that are important for nuclear astrophysics, especially the r-process. Prior to the on-line coupling to the reactor, TRIGA-TRAP already performed off-line mass measurements on stable and long-lived isotopes and will continue this program. The main focus within this thesis was on certain rare-earth nuclides in the well-established region of deformation around N ∝ 90. Another field of interest are mass measurements on actinoids to test mass models and to provide direct links to the mass standard. Within this thesis, the mass of 241 Am could be measured directly for the first time. (orig.)

  14. REVERBERATION MAPPING MEASUREMENTS OF BLACK HOLE MASSES IN SIX LOCAL SEYFERT GALAXIES

    International Nuclear Information System (INIS)

    Denney, K. D.; Peterson, B. M.; Pogge, R. W.; Atlee, D. W.; Bentz, M. C.; Bird, J. C.; Comins, M. L.; Dietrich, M.; Eastman, J. D.; Adair, A.; Au-Yong, K.; Chisholm, E.; Ewald, S.; Ferbey, S.; Jackson, K.; Brokofsky, D. J.; Gaskell, C. M.; Hedrick, C. H.; Doroshenko, V. T.; Efimov, Y. S.

    2010-01-01

    We present the final results from a high sampling rate, multi-month, spectrophotometric reverberation mapping campaign undertaken to obtain either new or improved Hβ reverberation lag measurements for several relatively low-luminosity active galactic nuclei (AGNs). We have reliably measured the time delay between variations in the continuum and Hβ emission line in six local Seyfert 1 galaxies. These measurements are used to calculate the mass of the supermassive black hole at the center of each of these AGNs. We place our results in context to the most current calibration of the broad-line region (BLR) R BLR -L relationship, where our results remove outliers and reduce the scatter at the low-luminosity end of this relationship. We also present velocity-resolved Hβ time-delay measurements for our complete sample, though the clearest velocity-resolved kinematic signatures have already been published.

  15. Mass measurements of {sup 238}U-projectile fragments for the first time with a multiple-reflection time-of-flight mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, Jens

    2016-07-01

    the experience of the first experiment in 2012 and the applied time-resolved calibration method a mass resolving power of 400,000 has been achieved in the experiment in 2014. The achieved mass accuracy in these pilot experiments were about 1 . 10{sup -6}. The contribution of the software and the resulting systematic errors were in the 10{sup -8} range. The reliability of the present analysis method was carefully checked in detailed simulations with a realistic peak shape approximated by an exponentially modified Gaussian distribution. Both list mode data and measured histograms were treated in the data analysis. The analysis method was tested with strongly overlapping mass distributions and low count rates including a variable amount of back ground. In summary, the experimental setup for mass measurements of very rare and short-lived nuclei and the corresponding data analysis have reached with this work and results of the present thesis a great potential for high-resolution measurements in future experiments. There mass measurements with 10 events can be performed with a residual uncertainty of 4.5 . 10{sup -7} at a mass resolving power of 400,000.

  16. Reliability measures in item response theory: manifest versus latent correlation functions.

    Science.gov (United States)

    Milanzi, Elasma; Molenberghs, Geert; Alonso, Ariel; Verbeke, Geert; De Boeck, Paul

    2015-02-01

    For item response theory (IRT) models, which belong to the class of generalized linear or non-linear mixed models, reliability at the scale of observed scores (i.e., manifest correlation) is more difficult to calculate than latent correlation based reliability, but usually of greater scientific interest. This is not least because it cannot be calculated explicitly when the logit link is used in conjunction with normal random effects. As such, approximations such as Fisher's information coefficient, Cronbach's α, or the latent correlation are calculated, allegedly because it is easy to do so. Cronbach's α has well-known and serious drawbacks, Fisher's information is not meaningful under certain circumstances, and there is an important but often overlooked difference between latent and manifest correlations. Here, manifest correlation refers to correlation between observed scores, while latent correlation refers to correlation between scores at the latent (e.g., logit or probit) scale. Thus, using one in place of the other can lead to erroneous conclusions. Taylor series based reliability measures, which are based on manifest correlation functions, are derived and a careful comparison of reliability measures based on latent correlations, Fisher's information, and exact reliability is carried out. The latent correlations are virtually always considerably higher than their manifest counterparts, Fisher's information measure shows no coherent behaviour (it is even negative in some cases), while the newly introduced Taylor series based approximations reflect the exact reliability very closely. Comparisons among the various types of correlations, for various IRT models, are made using algebraic expressions, Monte Carlo simulations, and data analysis. Given the light computational burden and the performance of Taylor series based reliability measures, their use is recommended. © 2014 The British Psychological Society.

  17. Reliability of Rehabilitative Ultrasonography to Measure Transverse Abdominis and Multifidus Muscle Dimensions

    International Nuclear Information System (INIS)

    Nabavi, Narjes; Mosallanezhad, Zahra; Haghighatkhah, Hamid Reza; Mohseni Bandpeid, Mohammad Ali

    2014-01-01

    Lumbar paraspinal muscles play an important role in providing both mobility and stability during dynamic tasks. Among paraspinal muscles, transverse abdominis and lumbar multifidus have been of particular interest as active stabilizers of the lumbar spine. These muscles may become dysfunctional in chronic low back pain (CLBP). Low back injury can result in muscle inhibition and control loss that cannot recover spontaneously, and specific exercises are required to stimulate their recovery. The purpose of this study was to test the reliability of ultrasonography to measure muscle dimensions and to present a reliable method for measuring transverse abdominis and lumbar multifidus as stabilizing muscles of the lumbar spine. Fifteen healthy participants (18-55 year olds) were evaluated by a radiologist using ultrasonography (ES500) with two probes (50mm linear 7.5 MHZ and 70 mm curvilinear 3.5 MHz). The muscle thickness of transverse abdominis and the anterior-posterior diameter and cross sectional area of the LMF were measured. To determine within and between days reliabilities, second and third measurements were repeated with half an hour and one week intervals, respectively. Intraclass correlation coefficient for left and right showed good to high reliability for the cross sectional area of lumbar multifidi (0.74 and 0.88, respectively) as well as the anterior-posterior dimensions of lumbar multifidi (0.89 and 0.91, respectively) and transverse abdomini thickness (0.73 and 0.85, respectively). Rehabilitative ultrasonography is a reliable and non-invasive instrument to measure muscle thickness. The method used in this study is a reliable way to measure lumbar stabilizing muscles

  18. Reliability of Frozen Section Examination in a Large Cohort of Testicular Masses: What Did We Learn?

    Science.gov (United States)

    Matei, Deliu Victor; Vartolomei, Mihai Dorin; Renne, Giuseppe; Tringali, Valeria Maria Lucia; Russo, Andrea; Bianchi, Roberto; Cozzi, Gabriele; Bottero, Danilo; Musi, Gennaro; Mazzarol, Giovanni; Ferro, Matteo; de Cobelli, Ottavio

    2017-08-01

    Frozen section examination (FSE) for testicular masses is gaining popularity because of the possibility of performing testis-sparing surgery (TSS) on the basis of the FSE results. The aim of our study was to investigate the reliability of FSE in the diagnosis of testicular masses. From 1999 to 2016, 144 of 692 patients who underwent surgery in our tertiary center for testicular masses had FSE. The indications for FSE were: masses < 1 cm, nonpalpable, multiple, or with unusual presentation. Mean follow-up for patients was 25.5 months. The algorithm of surgery determined by FSE was: orchiectomy if malignant or nonconclusive pathology; TSS if benign or nontumor pathology. FSE data were analyzed retrospectively. Specificity and sensitivity of the method was calculated for benign, malignant, seminoma, and nonseminoma tumors. Intraoperative FSE was conducted on 21% of candidates for surgery on testicular masses. The sensitivity and specificity of FSE were 93% and 98%, respectively, for malignant tumors, and 90% and 99%, respectively, for benign tumors. The κ agreement coefficient between FSE and final histopathology was statistically significant (0.76). TSS was performed in 57 (40%) patients, including 6 of 23 monorchid patients. FSE correlates well with final histopathological diagnosis of testicular masses. Thus, it reliably identifies patients who might benefit from TSS. FSE should be considered always in small, nonpalpable, multiple, or uncommonly presenting masses in solitary testis or both testes. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. A Study on the Reliability of Sasang Constitutional Body Trunk Measurement

    Directory of Open Access Journals (Sweden)

    Eunsu Jang

    2012-01-01

    Full Text Available Objective. Body trunk measurement for human plays an important diagnostic role not only in conventional medicine but also in Sasang constitutional medicine (SCM. The Sasang constitutional body trunk measurement (SCBTM consists of the 5-widths and the 8-circumferences which are standard locations currently employed in the SCM society. This study suggests to what extent a comprehensive training can improve the reliability of the SCBTM. Methods. We recruited 10 male subjects and 5 male observers with no experience of anthropometric measurement. We conducted measurements twice before and after a comprehensive training. Relative technical error of measurement (%TEMs was produced to assess intra and inter observer reliabilities. Results. Post-training intra-observer %TEMs of the SCBTM were 0.27% to 1.85% reduced from 0.27% to 6.26% in pre-training, respectively. Post-training inter-observer %TEMs of those were 0.56% to 1.66% reduced from 1.00% to 9.60% in pre-training, respectively. Post-training % total TEMs which represent the whole reliability were 0.68% to 2.18% reduced from maximum value of 10.18%. Conclusion. A comprehensive training makes the SCBTM more reliable, hence giving a sufficiently confident diagnostic tool. It is strongly recommended to give a comprehensive training in advance to take the SCBTM.

  20. A study on the reliability of sasang constitutional body trunk measurement.

    Science.gov (United States)

    Jang, Eunsu; Kim, Jong Yeol; Lee, Haejung; Kim, Honggie; Baek, Younghwa; Lee, Siwoo

    2012-01-01

    Objective. Body trunk measurement for human plays an important diagnostic role not only in conventional medicine but also in Sasang constitutional medicine (SCM). The Sasang constitutional body trunk measurement (SCBTM) consists of the 5-widths and the 8-circumferences which are standard locations currently employed in the SCM society. This study suggests to what extent a comprehensive training can improve the reliability of the SCBTM. Methods. We recruited 10 male subjects and 5 male observers with no experience of anthropometric measurement. We conducted measurements twice before and after a comprehensive training. Relative technical error of measurement (%TEMs) was produced to assess intra and inter observer reliabilities. Results. Post-training intra-observer %TEMs of the SCBTM were 0.27% to 1.85% reduced from 0.27% to 6.26% in pre-training, respectively. Post-training inter-observer %TEMs of those were 0.56% to 1.66% reduced from 1.00% to 9.60% in pre-training, respectively. Post-training % total TEMs which represent the whole reliability were 0.68% to 2.18% reduced from maximum value of 10.18%. Conclusion. A comprehensive training makes the SCBTM more reliable, hence giving a sufficiently confident diagnostic tool. It is strongly recommended to give a comprehensive training in advance to take the SCBTM.

  1. Improved radiograph measurement inter-observer reliability by use of statistical shape models

    Energy Technology Data Exchange (ETDEWEB)

    Pegg, E.C., E-mail: elise.pegg@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Mellon, S.J., E-mail: stephen.mellon@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Salmon, G. [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Alvand, A., E-mail: abtin.alvand@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Pandit, H., E-mail: hemant.pandit@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Murray, D.W., E-mail: david.murray@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Gill, H.S., E-mail: richie.gill@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom)

    2012-10-15

    Pre- and post-operative radiographs of patients undergoing joint arthroplasty are often examined for a variety of purposes including preoperative planning and patient assessment. This work examines the feasibility of using active shape models (ASM) to semi-automate measurements from post-operative radiographs for the specific case of the Oxford™ Unicompartmental Knee. Measurements of the proximal tibia and the position of the tibial tray were made using the ASM model and manually. Data were obtained by four observers and one observer took four sets of measurements to allow assessment of the inter- and intra-observer reliability, respectively. The parameters measured were the tibial tray angle, the tray overhang, the tray size, the sagittal cut position, the resection level and the tibial width. Results demonstrated improved reliability (average of 27% and 11.2% increase for intra- and inter-reliability, respectively) and equivalent accuracy (p > 0.05 for compared data values) for all of the measurements using the ASM model, with the exception of the tray overhang (p = 0.0001). Less time (15 s) was required to take measurements using the ASM model compared with manual measurements, which was significant. These encouraging results indicate that semi-automated measurement techniques could improve the reliability of radiographic measurements.

  2. Improved radiograph measurement inter-observer reliability by use of statistical shape models

    International Nuclear Information System (INIS)

    Pegg, E.C.; Mellon, S.J.; Salmon, G.; Alvand, A.; Pandit, H.; Murray, D.W.; Gill, H.S.

    2012-01-01

    Pre- and post-operative radiographs of patients undergoing joint arthroplasty are often examined for a variety of purposes including preoperative planning and patient assessment. This work examines the feasibility of using active shape models (ASM) to semi-automate measurements from post-operative radiographs for the specific case of the Oxford™ Unicompartmental Knee. Measurements of the proximal tibia and the position of the tibial tray were made using the ASM model and manually. Data were obtained by four observers and one observer took four sets of measurements to allow assessment of the inter- and intra-observer reliability, respectively. The parameters measured were the tibial tray angle, the tray overhang, the tray size, the sagittal cut position, the resection level and the tibial width. Results demonstrated improved reliability (average of 27% and 11.2% increase for intra- and inter-reliability, respectively) and equivalent accuracy (p > 0.05 for compared data values) for all of the measurements using the ASM model, with the exception of the tray overhang (p = 0.0001). Less time (15 s) was required to take measurements using the ASM model compared with manual measurements, which was significant. These encouraging results indicate that semi-automated measurement techniques could improve the reliability of radiographic measurements

  3. Volume and mass measurements of liquids

    International Nuclear Information System (INIS)

    Zander, M.

    1987-12-01

    The report comprises the 10 lectures given at the 74th PTB seminar, which represent the state of the art in the field of liquid flow measurement. The lectures deal with the overflow-pipette as the primary volume standard of PTB, gas elimination devices (compulsory in measuring assemblies with volume meters), measuring assemblies for the reception of milk, electromagnetic flowmeters, vortex-shedding meters, indirect mass measurement from volume and density, direct mass measurement (coriolis flowmeters), pipeline-measurements, level measurement at storage tanks with conventional and optical methods and a development aid project for the set up of test rigs in India. (orig.) [de

  4. Accurate mass measurements on neutron-deficient krypton isotopes

    CERN Document Server

    Rodríguez, D.; Äystö, J.; Beck, D.; Blaum, K.; Bollen, G.; Herfurth, F.; Jokinen, A.; Kellerbauer, A.; Kluge, H.-J.; Kolhinen, V.S.; Oinonen, M.; Sauvan, E.; Schwarz, S.

    2006-01-01

    The masses of $^{72–78,80,82,86}$Kr were measured directly with the ISOLTRAP Penning trap mass spectrometer at ISOLDE/CERN. For all these nuclides, the measurements yielded mass uncertainties below 10 keV. The ISOLTRAP mass values for $^{72–75}$Kr being more precise than the previous results obtained by means of other techniques, and thus completely determine the new values in the Atomic-Mass Evaluation. Besides the interest of these masses for nuclear astrophysics, nuclear structure studies, and Standard Model tests, these results constitute a valuable and accurate input to improve mass models. In this paper, we present the mass measurements and discuss the mass evaluation for these Kr isotopes.

  5. Top-quark mass and top-quark pole mass measurements with the ATLAS detector

    CERN Document Server

    Barillari, Teresa; The ATLAS collaboration

    2017-01-01

    Results of top-quark mass measurements in the di-lepton and in the all-jets top-antitop decay channels with the ATLAS detector are presented. The measurements are obtained using proton--proton collisions at a centre-of-mass energy \\sqrt{s} = 8 TeV at the CERN Large Hadron Collider. The data set used corresponds to an integrated luminosity of 20.2 fb-1. The top-quark mass in the di-lepton channel is measured to be 172.99 +/-0.41 (stat.) +/- 0.74 (syst.) GeV. In the all-jets analysis the top-quark mass is measured to be 173.72 +/- 0.55 (stat.)+/- 1.01 (syst.) GeV. In addition, the top-quark pole mass is determined from inclusive cross-section measurements in the top-antitop di-lepton decay channel with the ATLAS detector. The measurements are obtained using data at \\sqrt{s} = 7 TeV and \\sqrt{s} =8 TeV corresponding to an integrated luminosity of 4.6 fb-1 and 20.2 fb-1 respectively. The top-quark pole mass is measured to be 172.9^{+2.5}_{-2.6} GeV.

  6. Reliability-guided digital image correlation for image deformation measurement

    International Nuclear Information System (INIS)

    Pan Bing

    2009-01-01

    A universally applicable reliability-guided digital image correlation (DIC) method is proposed for reliable image deformation measurement. The zero-mean normalized cross correlation (ZNCC) coefficient is used to identify the reliability of the point computed. The correlation calculation begins with a seed point and is then guided by the ZNCC coefficient. That means the neighbors of the point with the highest ZNCC coefficient in a queue for computed points will be processed first. Thus the calculation path is always along the most reliable direction, and possible error propagation of the conventional DIC method can be avoided. The proposed novel DIC method is universally applicable to the images with shadows, discontinuous areas, and deformation discontinuity. Two image pairs were used to evaluate the performance of the proposed technique, and the successful results clearly demonstrate its robustness and effectiveness

  7. The role of test-retest reliability in measuring individual and group differences in executive functioning.

    Science.gov (United States)

    Paap, Kenneth R; Sawi, Oliver

    2016-12-01

    Studies testing for individual or group differences in executive functioning can be compromised by unknown test-retest reliability. Test-retest reliabilities across an interval of about one week were obtained from performance in the antisaccade, flanker, Simon, and color-shape switching tasks. There is a general trade-off between the greater reliability of single mean RT measures, and the greater process purity of measures based on contrasts between mean RTs in two conditions. The individual differences in RT model recently developed by Miller and Ulrich was used to evaluate the trade-off. Test-retest reliability was statistically significant for 11 of the 12 measures, but was of moderate size, at best, for the difference scores. The test-retest reliabilities for the Simon and flanker interference scores were lower than those for switching costs. Standard practice evaluates the reliability of executive-functioning measures using split-half methods based on data obtained in a single day. Our test-retest measures of reliability are lower, especially for difference scores. These reliability measures must also take into account possible day effects that classical test theory assumes do not occur. Measures based on single mean RTs tend to have acceptable levels of reliability and convergent validity, but are "impure" measures of specific executive functions. The individual differences in RT model shows that the impurity problem is worse than typically assumed. However, the "purer" measures based on difference scores have low convergent validity that is partly caused by deficiencies in test-retest reliability. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Reliability impact of RF tube technology for the NPB

    International Nuclear Information System (INIS)

    Bueck, J.C.

    1989-01-01

    Two reliability options, redundancy and operating margin, are examined to determine their effect on power system configurations using RF tube technology (klystron and klystrode) powered Neutral Particle Beam weapons. Redundance is addressed by providing an additional identical RF tube to the tubes required to power an accelerator RF element (DTL section, RFQ, or CCL). RF elements do not share RF power with other RF elements. Operating margin provides increased reliability by sizing the RF tubes such that tube operating levels may be increased compensate for the loss of a tube. It is shown that power system mass is affected by the choice of reliability measures, that higher power tubes coupled with higher power RF elements may mitigate mass increases, and that redundancy appears preferable to operating margin as a method of improving RF system reliability

  9. The Reliability of a Novel Mobile 3-dimensional Wound Measurement Device.

    Science.gov (United States)

    Anghel, Ersilia L; Kumar, Anagha; Bigham, Thomas E; Maselli, Kathryn M; Steinberg, John S; Evans, Karen K; Kim, Paul J; Attinger, Christopher E

    2016-11-01

    Objective assessment of wound dimensions is essential for tracking progression and determining treatment effectiveness. A reliability study was designed to establish intrarater and interrater reliability of a novel mobile 3-dimensional wound measurement (3DWM) device. Forty-five wounds were assessed by 2 raters using a 3DWM device to obtain length, width, area, depth, and volume measurements. Wounds were also measured manually, using a disposable ruler and digital planimetry. The intraclass correlation coefficient (ICC) was used to establish intrarater and interrater reliability. High levels of intrarater and interrater agreement were observed for area, length, and width; ICC = 0.998, 0.977, 0.955 and 0.999, 0.997, 0.995, respectively. Moderate levels of intrarater (ICC = 0.888) and interrater (ICC = 0.696) agreement were observed for volume. Lastly, depth yielded an intrarater ICC of 0.360 and an interrater ICC of 0.649. Measures from the 3DWM device were highly correlated with those obtained from scaled photography for length, width, and area (ρ = 0.997, 0.988, 0.997, P device yielded correlations of ρ = 0.990, 0.987, 0.996 with P device was found to be highly reliable for measuring wound areas for a range of wound sizes and types as compared to manual measurement and digital planimetry. The depth and therefore volume measurement using the 3DWM device was found to have a lower ICC, but volume ICC alone was moderate. Overall, this device offers a mobile option for objective wound measurement in the clinical setting.

  10. Reliability and Validity of Finger Strength and Endurance Measurements in Rock Climbing

    Science.gov (United States)

    Michailov, Michail Lubomirov; Baláš, Jirí; Tanev, Stoyan Kolev; Andonov, Hristo Stoyanov; Kodejška, Jan; Brown, Lee

    2018-01-01

    Purpose: An advanced system for the assessment of climbing-specific performance was developed and used to: (a) investigate the effect of arm fixation (AF) on construct validity evidence and reliability of climbing-specific finger-strength measurement; (b) assess reliability of finger-strength and endurance measurements; and (c) evaluate the…

  11. Measurement of $b$-hadron masses

    CERN Document Server

    Aaij, R; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amhis, Y; Anderson, J; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Arrabito, L; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Bailey, D S; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bates, A; Bauer, C; Bauer, Th; Bay, A; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blanks, C; Blouw, J; Blusk, S; Bobrov, A; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Büchler-Germann, A; Burducea, I; Bursche, A; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Cauet, Ch; Charles, M; Charpentier, Ph; Chiapolini, N; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Collins, P; Comerma-Montells, A; Constantin, F; Contu, A; Cook, A; Coombes, M; Corti, G; Cowan, G A; Currie, R; D'Ambrosio, C; David, P; David, P N Y; De Bonis, I; De Capua, S; De Cian, M; De Lorenzi, F; De Miranda, J M; De Paula, L; De Simone, P; Decamp, D; Deckenhoff, M; Degaudenzi, H; Del Buono, L; Deplano, C; Derkach, D; Deschamps, O; Dettori, F; Dickens, J; Dijkstra, H; Diniz Batista, P; Domingo Bonal, F; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Dziurda, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisele, F; Eisenhardt, S; Ekelhof, R; Eklund, L; Elsasser, Ch; Elsby, D; Esperante Pereira, D; Estève, L; Falabella, A; Fanchini, E; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Fernandez Albor, V; Ferro-Luzzi, M; Filippov, S; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Frank, M; Frei, C; Frosini, M; Furcas, S; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garnier, J-C; Garofoli, J; Garra Tico, J; Garrido, L; Gascon, D; Gaspar, C; Gauvin, N; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Gracianiv Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Haefeli, G; Haen, C; Haines, S C; Hampson, T; Hansmann-Menzemer, S; Harji, R; Harnew, N; Harrison, J; Harrison, P F; Hartmann, T; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Holubyev, K; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Huston, R S; Hutchcroft, D; Hynds, D; Iakovenko, V; Ilten, P; Imong, J; Jacobsson, R; Jaeger, A; Jahjah Hussein, M; Jans, E; Jansen, F; Jaton, P; Jean-Marie, B; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kaballo, M; Kandybei, S; Karacson, M; Karbach, T M; Keaveney, J; Kenyon, I R; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kim, Y M; Knecht, M; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kruzelecki, K; Kucharczyk, M; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Lesiak, T; Li, L; Li Gioi, L; Lieng, M; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; von Loeben, J; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Lu, H; Luisier, J; Mac Raighne, A; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Magnin, J; Malde, S; Mamunur, R M D; Manca, G; Mancinelli, G; Mangiafave, N; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinez Santos, D; Massafferri, A; Mathe, Z; Matteuzzi, C; Matveev, M; Maurice, E; Maynard, B; Mazurov, A; McGregor, G; McNulty, R; Meissner, M; Merk, M; Merkel, J; Messi, R; Miglioranzi, S; Milanes, D A; Minard, M-N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Musy, M; Mylroie-Smith, J; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Nedos, M; Needham, M; Neufeld, N; Nguyen-Mau, C; Nicol, M; Niess, V; Nikitin, N; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Pal, K; Palacios, J; Palano, A; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Paterson, S K; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petrella, A; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pie Valls, B; Pietrzyk, B; Pilař, T; Pinci, D; Plackett, R; Playfer, S; Plo Casasus, M; Polok, G; Poluektov, A; Polycarpo, E; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pugatch, V; Puig Navarro, A; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Rinnert, K; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodrigues, F; Rodriguez Perez, P; Rogers, G J; Roiser, S; Romanovsky, V; Rosello, M; Rouvinet, J; Ruf, T; Ruiz, H; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salzmann, C; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santinelli, R; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schleich, S; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skwarnicki, T; Smith, A C; Smith, N A; Smith, E; Sobczak, K; Soler, F J P; Solomin, A; Soomro, F; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Swientek, S; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Topp-Joergensen, S; Torr, N; Tournefier, E; Tran, M T; Tsaregorodtsev, A; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urquijo, P; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Viaud, B; Videau, I; Vilasis-Cardona, X; Visniakov, J; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Voss, H; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Witzeling, W; Wotton, S A; Wyllie, K; Xie, Y; Xing, F; Xing, Z; Yang, Z; Young, R; Yushchenko, O; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhong, L; Zverev, E; Zvyagin, A

    2012-01-01

    Measurements of $b$-hadron masses are performed with the exclusive decay modes $B^+\\to J/\\psi K^+$, $B^0 \\to J/\\psi K^{*0}$, $B^0 \\to J/\\psi K^0_{\\rm S}$, $B_s^0 \\to J/\\psi\\phi$ and $\\Lambda^0_b\\to J/\\psi\\Lambda$ using an integrated luminosity of 35 pb$^{-1}$ collected in $pp$ collisions at a centre-of-mass energy of 7 TeV by the LHCb experiment. The momentum scale is calibrated with $J/\\psi \\to \\mu^+\\mu^-$ decays and verified to be known to a relative precision of $2 \\times 10^{-4}$ using other two-body decays. The results are more precise than previous measurements, particularly in the case of the $B^0_s$ and $\\Lambda^0_b$ masses.

  12. Statistical Primer for Athletic Trainers: The Essentials of Understanding Measures of Reliability and Minimal Important Change.

    Science.gov (United States)

    Riemann, Bryan L; Lininger, Monica R

    2018-01-01

      To describe the concepts of measurement reliability and minimal important change.   All measurements have some magnitude of error. Because clinical practice involves measurement, clinicians need to understand measurement reliability. The reliability of an instrument is integral in determining if a change in patient status is meaningful.   Measurement reliability is the extent to which a test result is consistent and free of error. Three perspectives of reliability-relative reliability, systematic bias, and absolute reliability-are often reported. However, absolute reliability statistics, such as the minimal detectable difference, are most relevant to clinicians because they provide an expected error estimate. The minimal important difference is the smallest change in a treatment outcome that the patient would identify as important.   Clinicians should use absolute reliability characteristics, preferably the minimal detectable difference, to determine the extent of error around a patient's measurement. The minimal detectable difference, coupled with an appropriately estimated minimal important difference, can assist the practitioner in identifying clinically meaningful changes in patients.

  13. FIRST MEASUREMENTS OF THE MASS OF CORONAL MASS EJECTIONS FROM THE EUV DIMMING OBSERVED WITH STEREO EUVI A+B SPACECRAFT

    International Nuclear Information System (INIS)

    Aschwanden, Markus J.; Nitta, Nariaki V.; Wuelser, Jean-Pierre; Lemen, James R.; Sandman, Anne; Vourlidas, Angelos; Colaninno, Robin C.

    2009-01-01

    The masses of coronal mass ejections (CMEs) have traditionally been determined from white-light coronagraphs (based on Thomson scattering of electrons), as well as from extreme ultraviolet (EUV) dimming observed with one spacecraft. Here we develop an improved method of measuring CME masses based on EUV dimming observed with the dual STEREO/EUVI spacecraft in multiple temperature filters that includes three-dimensional volume and density modeling in the dimming region and background corona. As a test, we investigate eight CME events with previous mass determinations from STEREO/COR2, of which six cases are reliably detected with the Extreme Ultraviolet Imager (EUVI) using our automated multi-wavelength detection code. We find CME masses in the range of m CME = (2-7) x 10 15 g. The agreement between the two EUVI/A and B spacecraft is m A /m B = 1.3 ± 0.6 and the consistency with white-light measurements by COR2 is m EUVI /m COR2 = 1.1 ± 0.3. The consistency between EUVI and COR2 implies no significant mass backflows (or inflows) at r sun and adequate temperature coverage for the bulk of the CME mass in the range of T ∼ 0.5-3.0 MK. The temporal evolution of the EUV dimming allows us to also model the evolution of the CME density n e (t), volume V(t), height-time h(t), and propagation speed v(t) in terms of an adiabatically expanding self-similar geometry. We determine e-folding EUV dimming times of t D = 1.3 ± 1.4 hr. We test the adiabatic expansion model in terms of the predicted detection delay (Δt ∼ 0.7 hr) between EUVI and COR2 for the fastest CME event (2008 March 25) and find good agreement with the observed delay (Δt ∼ 0.8 hr).

  14. Tactile acuity charts: a reliable measure of spatial acuity.

    Science.gov (United States)

    Bruns, Patrick; Camargo, Carlos J; Campanella, Humberto; Esteve, Jaume; Dinse, Hubert R; Röder, Brigitte

    2014-01-01

    For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds.

  15. Reliability and concurrent validity of postural asymmetry measurement in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Prowse, Ashleigh; Aslaksen, Berit; Kierkegaard, Marie; Furness, James; Gerdhem, Paul; Abbott, Allan

    2017-01-18

    To investigate the reliability and concurrent validity of the Baseline ® Body Level/Scoliosis meter for adolescent idiopathic scoliosis postural assessment in three anatomical planes. This is an observational reliability and concurrent validity study of adolescent referrals to the Orthopaedic department for scoliosis screening at Karolinska University Hospital, Stockholm, Sweden between March-May 2012. A total of 31 adolescents with idiopathic scoliosis (13.6 ± 0.6 years old) of mild-moderate curvatures (25° ± 12°) were consecutively recruited. Measurement of cervical, thoracic and lumbar curvatures, pelvic and shoulder tilt, and axial thoracic rotation (ATR) were performed by two trained physiotherapists in one day. The intraclass correlation coefficient (ICC) was used to determine the inter-examiner reliability (ICC2,1) and the intra-rater reliability (ICC3,3) of the Baseline ® Body Level/Scoliosis meter. Spearman's correlation analyses were used to estimate concurrent validity between the Baseline ® Body Level/Scoliosis meter and Gold Standard Cobb angles from radiographs and the Orthopaedic Systems Inc. Scoliometer. There was excellent reliability between examiners for thoracic kyphosis (ICC2,1 = 0.94), ATR (ICC2,1 = 0.92) and lumbar lordosis (ICC2,1 = 0.79). There was adequate reliability between examiners for cervical lordosis (ICC2,1 = 0.51), however poor reliability for pelvic and shoulder tilt. Both devices were reproducible in the measurement of ATR when repeated by one examiner (ICC3,3 0.98-1.00). The device had a good correlation with the Scoliometer (rho = 0.78). When compared with Cobb angle from radiographs, there was a moderate correlation for ATR (rho = 0.627). The Baseline ® Body Level/Scoliosis meter provides reliable transverse and sagittal cervical, thoracic and lumbar measurements and valid transverse plan measurements of mild-moderate scoliosis deformity.

  16. Self-report measures of prospective memory are reliable but not valid.

    Science.gov (United States)

    Uttl, Bob; Kibreab, Mekale

    2011-03-01

    Are self-report measures of prospective memory (ProM) reliable and valid? To examine this question, 240 undergraduate student volunteers completed several widely used self-report measures of ProM including the Prospective Memory Questionnaire (PMQ), the Prospective and Retrospective Memory Questionnaire (PRMQ), the Comprehensive Assessment of Prospective Memory (CAPM) questionnaire, self-reports of retrospective memory (RetM), objective measures of ProM and RetM, and measures of involvement in activities and events, memory strategies and aids use, personality and verbal intelligence. The results showed that both convergent and divergent validity of ProM self-reports are poor, even though we assessed ProM using a newly developed, reliable continuous measure. Further analyses showed that a substantial proportion of variability in ProM self-report scores was due to verbal intelligence, personality (conscientiousness, neuroticism), activities and event involvement (busyness), and use of memory strategies and aids. ProM self-reports have adequate reliability, but poor validity and should not be interpreted as reflecting ProM ability. (PsycINFO Database Record (c) 2011 APA, all rights reserved).

  17. Three-dimensional Mass Measurement of Subsolid Pulmonary Nodules on Chest CT: Intra and Inter-observer Variability

    Directory of Open Access Journals (Sweden)

    Huiting LIU

    2015-05-01

    Full Text Available Background and objective Subsolid pulmonary nodules tend to exhibit considerably slower growth rates than solid lesions, nevertheless, higher malignancy probability. The diagnosis of indeterminate nodules largely depends on the growth evaluation during follow-up. The growth can manifested as an increase in size or the appearance and/or subsequent increase of solid components. The mass reflect the product of volume and density and can be more sensitive in growth evaluation. However, the repeatability needs a further validation. The purpose of this study is to assess the intra and inter-observer variability of mass measurement for subsolid nodules. Methods 80 subsolid nodules in 44 patients were retrospectively enrolled. Both the volume and mass were measured by two radiologists using blind method independently. Intra-observer and inter-observer variability were analyzed and compared by Bland-Altman method intra-class correlation test and Wilcoxon test. Results Software achieved satisfied segmentation for 92.5% nodules. Of them, 35% underwent manual modification. The 95% limits of agreement for intra-observer variability were -11.5%-10.4% for mass and -8.4%-8.8% for volume. The 95% limits of agreement for inter-observer variability were -17.4%-19.3% for mass and -17.9%-19.4% for volume.The intra-class correlation foefficients between volume and mass measument was 0.95 and 0.93 (both P<0.001 and no significant differences (P=0.78, 0.09 was found for intra- and inter-observer variability. Manual modification of the segmentation caused the worse mass measurement repeatability in spite of the reader satisfaction. Conclusion The repeatability of mass measurement has no significant difference with that of volume measurement and may act as a reliable method in the follow-up of subsolid nodules.

  18. Reliability of Two Smartphone Applications for Radiographic Measurements of Hallux Valgus Angles.

    Science.gov (United States)

    Mattos E Dinato, Mauro Cesar; Freitas, Marcio de Faria; Milano, Cristiano; Valloto, Elcio; Ninomiya, André Felipe; Pagnano, Rodrigo Gonçalves

    The objective of the present study was to assess the reliability of 2 smartphone applications compared with the traditional goniometer technique for measurement of radiographic angles in hallux valgus and the time required for analysis with the different methods. The radiographs of 31 patients (52 feet) with a diagnosis of hallux valgus were analyzed. Four observers, 2 with >10 years' experience in foot and ankle surgery and 2 in-training surgeons, measured the hallux valgus angle and intermetatarsal angle using a manual goniometer technique and 2 smartphone applications (Hallux Angles and iPinPoint). The interobserver and intermethod reliability were estimated using intraclass correlation coefficients (ICCs), and the time required for measurement of the angles among the 3 methods was compared using the Friedman test. A very good or good interobserver reliability was found among the 4 observers measuring the hallux valgus angle and intermetatarsal angle using the goniometer (ICC 0.913 and 0.821, respectively) and iPinPoint (ICC 0.866 and 0.638, respectively). Using the Hallux Angles application, a very good interobserver reliability was found for measurements of the hallux valgus angle (ICC 0.962) and intermetatarsal angle (ICC 0.935) only among the more experienced observers. The time required for the measurements was significantly shorter for the measurements using both smartphone applications compared with the goniometer method. One smartphone application (iPinPoint) was reliable for measurements of the hallux valgus angles by either experienced or nonexperienced observers. The use of these tools might save time in the evaluation of radiographic angles in the hallux valgus. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  19. THE RELIABILITY AND ACCURACY OF THE TRIPLE MEASUREMENTS OF ANALOG PROCESS VARIABLES

    Directory of Open Access Journals (Sweden)

    V. A. Anishchenko

    2017-01-01

    Full Text Available The increase in unit capacity of electric equipment as well as complication of technological processes, devices control and management of the latter in power plants and substations demonstrate the need to improve the reliability and accuracy of measurement information characterizing the state of the objects being managed. The mentioned objective is particularly important for nuclear power plants, where the price of inaccuracy of measurement responsible process variables is particularly high and the error might lead to irreparable consequences. Improving the reliability and accuracy of measurements along with the improvement of the element base is provided by methods of operational validation. These methods are based on the use of information redundancy (structural, topological, temporal. In particular, information redundancy can be achieved by the simultaneous measurement of one analog variable by two (duplication or three devices (triplication i.e., triple redundancy. The problem of operational control of the triple redundant system of measurement of electrical analog variables (currents, voltages, active and reactive power and energy is considered as a special case of signal processing by an orderly sampling on the basis of majority transformation and transformation being close to majority one. Difficulties in monitoring the reliability of measurements are associated with the two tasks. First, one needs to justify the degree of truncation of the distributions of random errors of measurements and allowable residuals of the pairwise differences of the measurement results. The second task consists in formation of the algorithm of joint processing of a set of separate measurements determined as valid. The quality of control is characterized by the reliability, which adopted the synonym of validity, and accuracy of the measuring system. Taken separately, these indicators might lead to opposite results. A compromise solution is therefore proposed

  20. Ratio method of measuring W boson mass

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Feng [Stony Brook Univ., NY (United States)

    2010-08-01

    This dissertation describes an alternative method of measuring the W boson mass in DØ experiment. Instead of extracting MW from the fitting of W → ev fast Monte Carlo simulations to W → ev data as in the standard method, we make the direct fit of transverse mass between W → ev data and Z → ee data. One of the two electrons from Z boson is treated as a neutrino in the calculation of transverse mass. In ratio method, the best fitted scale factor corresponds to the ratio of W and Z boson mass (MW/MZ). Given the precisely measured Z boson mass, W mass is directly fitted from W → ev and Z → ee data. This dissertation demonstrates that ratio method is a plausible method of measuring the W boson mass. With the 1 fb-1 DØ Run IIa dataset, ratio method gives MW = 80435 ± 43(stat) ± 26(sys) MeV.

  1. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease.

    Science.gov (United States)

    Strouwen, Carolien; Molenaar, Esther A L M; Keus, Samyra H J; Münks, Liesbeth; Bloem, Bastiaan R; Nieuwboer, Alice

    2016-08-01

    Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains largely unknown. The purpose of this study was to assess the reliability of DT outcome measures in patients with PD. A repeated-measures design was used. Patients with PD ("on" medication, Mini-Mental State Examination score ≥24) performed 2 cognitive tasks (ie, backward digit span task and auditory Stroop task) and 1 functional task (ie, mobile phone task) in combination with walking. Tasks were assessed at 2 time points (same hour) with an interval of 6 weeks. Test-retest reliability was assessed for gait while performing each secondary task (DT gait) for both cognitive tasks while walking (DT cognitive) and for the functional task while walking (DT functional). Sixty-two patients with PD (age=39-89 years, Hoehn and Yahr stages II-III) were included in the study. Intraclass correlation coefficients (ICCs) showed excellent reliability for DT gait measures, ranging between .86 and .95 when combined with the digit span task, between .86 and .95 when combined with the auditory Stroop task, and between .72 and .90 when combined with the mobile phone task. The standard error of measurements for DT gait speed varied between 0.06 and 0.08 m/s, leading to minimal detectable changes between 0.16 and 0.22 m/s. With regard to DT cognitive measures, reaction times showed good-to-excellent reliability (digit span task: ICC=.75; auditory Stroop task: ICC=.82). The results cannot be generalized to patients with advanced disease or to other DT measures. In people with PD, DT measures proved to be reliable for use in clinical studies and look promising for use in clinical practice to assess improvements after DT training. Large effects, however, are needed to obtain meaningful effect sizes.

  3. The Reliability of Lumbar Lordosis Measurements Using a Flexible-Rule.

    Science.gov (United States)

    The purpose of this study was to examine the intra-rater and intra-rater reliability of lumbar lordosis measurements taken with a flexible-rule. Two...coefficients (ICC) were used to determine the degree of agreement between measurements. The results suggest that measurements of lumbar lordosis with a

  4. Reliability and validity of the AutoCAD software method in lumbar lordosis measurement.

    Science.gov (United States)

    Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe

    2011-12-01

    The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis.

  5. The Children's Body Image Scale: reliability and use with international standards for body mass index.

    Science.gov (United States)

    Truby, Helen; Paxton, Susan J

    2008-03-01

    To test the reliability of the Children's Body Image Scale (CBIS) and assess its usefulness in the context of new body size charts for children. Participants were 281 primary schoolchildren with 50% being retested after 3 weeks. The CBIS figure scale was compared with a range of international body mass index (BMI) reference standards. Children had a high degree of body image dissatisfaction. The test-retest reliability of the CBIS was supported. The CBIS is a useful tool for assessing body image in children with sound scale properties. It can also be used to identify the body size of children, which lies outside the healthy weight range of BMI.

  6. A test chip for automatic reliability measurements of interconnect vias

    NARCIS (Netherlands)

    Lippe, K.; Hasper, A.; Elfrink, G.W.; Niehof, J.; Kerkhoff, Hans G.

    1992-01-01

    A test circuit for electromigration reliability measurements was designed and tested. The device under test (DUT) is a via-hole chain. The test circuit permits simultaneous measurements of a number of DUTs, and a fatal error of one DUT does not influence the measurement results of the other DUTs.

  7. Using LISREL to Evaluate Measurement Models and Scale Reliability.

    Science.gov (United States)

    Fleishman, John; Benson, Jeri

    1987-01-01

    LISREL program was used to examine measurement model assumptions and to assess reliability of Coopersmith Self-Esteem Inventory for Children, Form B. Data on 722 third-sixth graders from over 70 schools in large urban school district were used. LISREL program assessed (1) nature of basic measurement model for scale, (2) scale invariance across…

  8. Tactile acuity charts: a reliable measure of spatial acuity.

    Directory of Open Access Journals (Sweden)

    Patrick Bruns

    Full Text Available For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds.

  9. Reliability of surface EMG measurements from the suprahyoid muscle complex

    DEFF Research Database (Denmark)

    Kothari, Mohit; Stubbs, Peter William; Pedersen, Asger Roer

    2017-01-01

    of using the suprahyoid muscle complex (SMC) using surface electromyography (sEMG) to assess changes to neural pathways by determining the reliability of measurements in healthy participants over days. Methods: Seventeen healthy participants were recruited. Measurements were performed twice with one week...... on stimulus type/intensity) had significantly different MEP values between day 1 and day 2 for single pulse and paired pulse TMS. A large stimulus artefact resulted in MEP responses that could not be assessed in four participants. Conclusions: The assessment of the SMC using sEMG following TMS was poorly...... reliable for ≈50% of participants. Although using sEMG to assess swallowing musculature function is easier to perform clinically and more comfortable to patients than invasive measures, as the measurement of muscle activity using TMS is unreliable, the use of sEMG for this muscle group is not recommended...

  10. Recommendations for certification or measurement of reliability for reliable digital archival repositories with emphasis on access

    Directory of Open Access Journals (Sweden)

    Paula Regina Ventura Amorim Gonçalez

    2017-04-01

    Full Text Available Introduction: Considering the guidelines of ISO 16363: 2012 (Space data and information transfer systems -- Audit and certification of trustworthy digital repositories and the text of CONARQ Resolution 39 for certification of Reliable Digital Archival Repository (RDC-Arq, verify the technical recommendations should be used as the basis for a digital archival repository to be considered reliable. Objective: Identify requirements for the creation of Reliable Digital Archival Repositories with emphasis on access to information from the ISO 16363: 2012 and CONARQ Resolution 39. Methodology: For the development of the study, the methodology consisted of an exploratory, descriptive and documentary theoretical investigation, since it is based on ISO 16363: 2012 and CONARQ Resolution 39. From the perspective of the problem approach, the study is qualitative and quantitative, since the data were collected, tabulated, and analyzed from the interpretation of their contents. Results: We presented a set of Checklist Recommendations for reliability measurement and/or certification for RDC-Arq with a clipping focused on the identification of requirements with emphasis on access to information is presented. Conclusions: The right to information as well as access to reliable information is a premise for Digital Archival Repositories, so the set of recommendations is directed to archivists who work in Digital Repositories and wish to verify the requirements necessary to evaluate the reliability of the Digital Repository or still guide the information professional in collecting requirements for repository reliability certification.

  11. Procedure of non-contacting local mass density and mass density distribution measurements

    International Nuclear Information System (INIS)

    Menzel, M.; Winkler, K.

    1985-01-01

    The invention has been aimed at a procedure of non-contacting local mass density and/or mass density distribution measurements i.e. without the interfering influence of sensors or probes. It can be applied to installations, apparatuses and pipings of chemical engineering, to tank constructions and transportation on extreme temperature and/or pressure conditions and aggressive media influences respectively. The procedure has utilized an ionizing quantum radiation whereby its unknown weakening and scattering is compensated by a suitable combination of scattering and transmission counter rate measurements in such a way that the local mass densities and the mass density distribution respectively are determinable

  12. Validity and reliability of GPS and LPS for measuring distances covered and sprint mechanical properties in team sports.

    Science.gov (United States)

    Hoppe, Matthias W; Baumgart, Christian; Polglaze, Ted; Freiwald, Jürgen

    2018-01-01

    This study aimed to investigate the validity and reliability of global (GPS) and local (LPS) positioning systems for measuring distances covered and sprint mechanical properties in team sports. Here, we evaluated two recently released 18 Hz GPS and 20 Hz LPS technologies together with one established 10 Hz GPS technology. Six male athletes (age: 27±2 years; VO2max: 48.8±4.7 ml/min/kg) performed outdoors on 10 trials of a team sport-specific circuit that was equipped with double-light timing gates. The circuit included various walking, jogging, and sprinting sections that were performed either in straight-lines or with changes of direction. During the circuit, athletes wore two devices of each positioning system. From the reported and filtered velocity data, the distances covered and sprint mechanical properties (i.e., the theoretical maximal horizontal velocity, force, and power output) were computed. The sprint mechanical properties were modeled via an inverse dynamic approach applied to the center of mass. The validity was determined by comparing the measured and criterion data via the typical error of estimate (TEE), whereas the reliability was examined by comparing the two devices of each technology (i.e., the between-device reliability) via the coefficient of variation (CV). Outliers due to measurement errors were statistically identified and excluded from validity and reliability analyses. The 18 Hz GPS showed better validity and reliability for determining the distances covered (TEE: 1.6-8.0%; CV: 1.1-5.1%) and sprint mechanical properties (TEE: 4.5-14.3%; CV: 3.1-7.5%) than the 10 Hz GPS (TEE: 3.0-12.9%; CV: 2.5-13.0% and TEE: 4.1-23.1%; CV: 3.3-20.0%). However, the 20 Hz LPS demonstrated superior validity and reliability overall (TEE: 1.0-6.0%; CV: 0.7-5.0% and TEE: 2.1-9.2%; CV: 1.6-7.3%). For the 10 Hz GPS, 18 Hz GPS, and 20 Hz LPS, the relative loss of data sets due to measurement errors was 10.0%, 20.0%, and 15.8%, respectively. This study shows that

  13. Direct neutrino mass measurements

    Energy Technology Data Exchange (ETDEWEB)

    Weinheimer, Christian, E-mail: weinheimer@uni-muenster.de [Westfaelische Wilhelms-Universitaet, Institut fuer Kernphysik (Germany)

    2013-03-15

    Direct neutrino mass experiments are complementary to searches for neutrinoless double {beta}-decay and to analyses of cosmological data. The previous tritium beta decay experiments at Mainz and at Troitsk have achieved upper limits on the neutrino mass of about 2 eV/c{sup 2} . The KATRIN experiment under construction will improve the neutrino mass sensitivity down to 200 meV/c{sup 2} by increasing strongly the statistics and-at the same time-reducing the systematic uncertainties. Huge improvements have been made to operate the system extremely stably and at very low background rate. The latter comprises new methods to reject secondary electrons from the walls as well as to avoid and to eject electrons stored in traps. As an alternative to tritium {beta}-decay experiments cryo-bolometers investigating the endpoint region of {sup 187}Re {beta}-decay or the electron capture of {sup 163}Ho are being developed. This article briefly reviews the current status of the direct neutrino mass measurements.

  14. Semiconductor measurement technology: reliability technology for cardiac pacemakers 2: a workshop report, 1976

    International Nuclear Information System (INIS)

    Schafft, H.A.

    1977-01-01

    Summaries are presented of 12 invited talks on the following topics: the procurement and assurance of high reliability electronic parts, leak rate and moisture measurements, pacemaker batteries, and pacemaker leads. The workshop, second in a series, was held in response to strong interest expressed by the pacemaker community to address technical questions relevant to the enhancement and assurance of cardiac pacemaker reliability. Discussed at the workshop were a process validation wafer concept for assuring process uniformity in device chips; screen tests for assuring reliable electronic parts; reliability prediction; reliability comparison of semiconductor technologies; mechanisms of short-circuiting dendritic growths; details of helium and radioisotope leak test methods; a study to correlate package leak rates, as measured with test gasses, and actual moisture infusion; battery life prediction; microcalorimetric measurements to nondestructively evaluate batteries for pacemakers; and an engineer's and a physician's view of the present status of pacemaker leads. References are included with most of the reports

  15. A method of bias correction for maximal reliability with dichotomous measures.

    Science.gov (United States)

    Penev, Spiridon; Raykov, Tenko

    2010-02-01

    This paper is concerned with the reliability of weighted combinations of a given set of dichotomous measures. Maximal reliability for such measures has been discussed in the past, but the pertinent estimator exhibits a considerable bias and mean squared error for moderate sample sizes. We examine this bias, propose a procedure for bias correction, and develop a more accurate asymptotic confidence interval for the resulting estimator. In most empirically relevant cases, the bias correction and mean squared error correction can be performed simultaneously. We propose an approximate (asymptotic) confidence interval for the maximal reliability coefficient, discuss the implementation of this estimator, and investigate the mean squared error of the associated asymptotic approximation. We illustrate the proposed methods using a numerical example.

  16. Measuring older adults' sedentary time: reliability, validity, and responsiveness.

    Science.gov (United States)

    Gardiner, Paul A; Clark, Bronwyn K; Healy, Genevieve N; Eakin, Elizabeth G; Winkler, Elisabeth A H; Owen, Neville

    2011-11-01

    With evidence that prolonged sitting has deleterious health consequences, decreasing sedentary time is a potentially important preventive health target. High-quality measures, particularly for use with older adults, who are the most sedentary population group, are needed to evaluate the effect of sedentary behavior interventions. We examined the reliability, validity, and responsiveness to change of a self-report sedentary behavior questionnaire that assessed time spent in behaviors common among older adults: watching television, computer use, reading, socializing, transport and hobbies, and a summary measure (total sedentary time). In the context of a sedentary behavior intervention, nonworking older adults (n = 48, age = 73 ± 8 yr (mean ± SD)) completed the questionnaire on three occasions during a 2-wk period (7 d between administrations) and wore an accelerometer (ActiGraph model GT1M) for two periods of 6 d. Test-retest reliability (for the individual items and the summary measure) and validity (self-reported total sedentary time compared with accelerometer-derived sedentary time) were assessed during the 1-wk preintervention period, using Spearman (ρ) correlations and 95% confidence intervals (CI). Responsiveness to change after the intervention was assessed using the responsiveness statistic (RS). Test-retest reliability was excellent for television viewing time (ρ (95% CI) = 0.78 (0.63-0.89)), computer use (ρ (95% CI) = 0.90 (0.83-0.94)), and reading (ρ (95% CI) = 0.77 (0.62-0.86)); acceptable for hobbies (ρ (95% CI) = 0.61 (0.39-0.76)); and poor for socializing and transport (ρ < 0.45). Total sedentary time had acceptable test-retest reliability (ρ (95% CI) = 0.52 (0.27-0.70)) and validity (ρ (95% CI) = 0.30 (0.02-0.54)). Self-report total sedentary time was similarly responsive to change (RS = 0.47) as accelerometer-derived sedentary time (RS = 0.39). The summary measure of total sedentary time has good repeatability and modest validity and is

  17. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease

    NARCIS (Netherlands)

    Strouwen, C.; Molenaar, E.A.; Keus, S.H.; Munks, L.; Bloem, B.R.; Nieuwboer, A.

    2016-01-01

    BACKGROUND: Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains

  18. Reliability analysis for manual radiographic measures of rotatory subluxation or lateral listhesis in adult scoliosis.

    Science.gov (United States)

    Freedman, Brett A; Horton, William C; Rhee, John M; Edwards, Charles C; Kuklo, Timothy R

    2009-03-15

    Retrospective observational study. To define the inter- and intraobserver reliability of 3 measures of rotatory subluxation (RS) in adult scoliosis (AS). RS is a hallmark of AS. To accurately track this measure, one must know its reliability. Reliability testing has not been performed. PA 36" films of 29 AS patients were collected from one surgeon's practice. Three observers on 2 separate occasions measured all levels with >or=3-mm RS (60 levels, 360 measurements) on the convexity of the involved segment using 3 different techniques-midbody (MB), endplate (EP), and centroid (C). These data were then analyzed to determine the intraclass correlation coefficient (ICC) for inter- and intraobserver reliability. The thoracolumbar/lumbar curve (average 58 degrees ) was the major curve for the majority (62%) of patients. RS at L3/4 was most common (35%). The overall inter- and intraobserver reliability was good-excellent for all methods, but the centroid method consistently had the highest ICC. ICC correlated with observer experience. Moderate-severe arthritic change (present in 55%) and poor image quality (52%) decreased ICC, but it still remained good-excellent for each measure. The reproducibility coefficient for each measure was 4 mm for MB and 2.8 mm for C and EP. MB, EP, and C are reliable techniques to measure RS even in elderly arthritic spines, but the methods inherently produce different values for a given level. The centroid method is most reliable and least influenced by experience. The EP method is easy to perform and very reliable. Spine surgeons should pick their preferred method and apply it consistently. Changes >3 mm suggest RS progression. RS may be a useful measure in addition to Cobb angle in AS. Having defined measurement reliability, the role of RS progression in surgical indications and patient outcomes can be evaluated.

  19. Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines

    Directory of Open Access Journals (Sweden)

    Cameron Alyse FM

    2009-11-01

    Full Text Available Abstract Background Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end Philips HD11 Ultrasound machine and clinically orientated Chison 8300 Deluxe Digital Portable Ultrasound System. Methods The abductor hallucis muscle of both the left and right feet of thirty asymptomatic participants was imaged and then measured using both ultrasound machines. Interclass correlation coefficients (ICC with 95% confidence intervals (CI were used to calculate both within and between session intra-tester reliability. Standard error of the measurement (SEM calculations were undertaken to assess difference between the actual measured score across trials and the smallest real difference (SRD was calculated from the SEM to indicate the degree of change that would exceed the expected trial to trial variability. Results The ICCs, SEM and SRD for dorso-plantar thickness and medial-lateral length were shown to have excellent to high within and between-session reliability for both ultrasound machines. The between-session reliability indices for cross-sectional area were acceptable for both ultrasound machines. Conclusion The results of the current study suggest that regardless of the type ultrasound machine, intra-tester reliability for the measurement the abductor hallucis muscle parameters is very high.

  20. A new measurement of workload in Web application reliability assessment

    Directory of Open Access Journals (Sweden)

    CUI Xia

    2015-02-01

    Full Text Available Web application has been popular in various fields of social life.It becomes more and more important to study the reliability of Web application.In this paper the definition of Web application failure is firstly brought out,and then the definition of Web application reliability.By analyzing data in the IIS server logs and selecting corresponding usage and information delivery failure data,the paper study the feasibility of Web application reliability assessment from the perspective of Web software system based on IIS server logs.Because the usage for a Web site often has certain regularity,a new measurement of workload in Web application reliability assessment is raised.In this method,the unit is removed by weighted average technique;and the weights are assessed by setting objective function and optimization.Finally an experiment was raised for validation.The experiment result shows the assessment of Web application reliability base on the new workload is better.

  1. Penning trap mass measurements on nobelium isotopes

    International Nuclear Information System (INIS)

    Dworschak, M.; Block, M.; Ackermann, D.; Herfurth, F.; Hessberger, F. P.; Hofmann, S.; Vorobyev, G. K.; Audi, G.; Blaum, K.; Droese, C.; Marx, G.; Schweikhard, L.; Eliseev, S.; Ketter, J.; Fleckenstein, T.; Haettner, E.; Plass, W. R.; Scheidenberger, C.; Ketelaer, J.; Kluge, H.-J.

    2010-01-01

    The Penning trap mass spectrometer SHIPTRAP at GSI Darmstadt allows accurate mass measurements of radionuclides, produced in fusion-evaporation reactions and separated by the velocity filter SHIP from the primary beam. Recently, the masses of the three nobelium isotopes 252-254 No were determined. These are the first direct mass measurements of transuranium elements, which provide new anchor points in this region. The heavy nuclides were produced in cold-fusion reactions by irradiating a PbS target with a 48 Ca beam, resulting in production rates of the nuclei of interest of about one atom per second. In combination with data from decay spectroscopy our results are used to perform a new atomic-mass evaluation in this region.

  2. Measurement of b-hadron masses

    Energy Technology Data Exchange (ETDEWEB)

    Aaij, R. [Nikhef National Institute for Subatomic Physics, Amsterdam (Netherlands); Abellan Beteta, C. [Universitat de Barcelona, Barcelona (Spain); Adeva, B. [Universidad de Santiago de Compostela, Santiago de Compostela (Spain); Adinolfi, M. [H.H. Wills Physics Laboratory, University of Bristol, Bristol (United Kingdom); Adrover, C. [CPPM, Aix-Marseille Universite, CNRS/IN2P3, Marseille (France); Affolder, A. [Oliver Lodge Laboratory, University of Liverpool, Liverpool (United Kingdom); Ajaltouni, Z. [Clermont Universite, Universite Blaise Pascal, CNRS/IN2P3, LPC, Clermont-Ferrand (France); Albrecht, J.; Alessio, F. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Alexander, M. [School of Physics and Astronomy, University of Glasgow, Glasgow (United Kingdom); Alkhazov, G. [Petersburg Nuclear Physics Institute (PNPI), Gatchina (Russian Federation); Alvarez Cartelle, P. [Universidad de Santiago de Compostela, Santiago de Compostela (Spain); Alves, A.A. [Sezione INFN di Roma La Sapienza, Roma (Italy); Amato, S. [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro (Brazil); Amhis, Y. [Ecole Polytechnique Federale de Lausanne (EPFL), Lausanne (Switzerland); Anderson, J. [Physik-Institut, Universitaet Zuerich, Zuerich (Switzerland); Appleby, R.B. [School of Physics and Astronomy, University of Manchester, Manchester (United Kingdom); Aquines Gutierrez, O. [Max-Planck-Institut fuer Kernphysik (MPIK), Heidelberg (Germany); Archilli, F. [Laboratori Nazionali dell' INFN di Frascati, Frascati (Italy); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Arrabito, L. [CC-IN2P3, CNRS/IN2P3, Lyon-Villeurbanne (France); and others

    2012-02-28

    Measurements of b-hadron masses are performed with the exclusive decay modes B{sup +}{yields}J/{psi}K{sup +}, B{sup 0}{yields}J/{psi}K{sup Low-Asterisk 0}, B{sup 0}{yields}J/{psi}K{sub S}{sup 0}, B{sub s}{sup 0}{yields}J/{psi}{phi} and {Lambda}{sub b}{sup 0}{yields}J/{psi}{Lambda} using an integrated luminosity of 35 pb{sup -1} collected in pp collisions at a centre-of-mass energy of 7 TeV by the LHCb experiment. The momentum scale is calibrated with J/{psi}{yields}{mu}{sup +}{mu}{sup -} decays and verified to be known to a relative precision of 2 Multiplication-Sign 10{sup -4} using other two-body decays. The results are more precise than previous measurements, particularly in the case of the B{sub s}{sup 0} and {Lambda}{sub b}{sup 0} masses.

  3. Top Quark Mass Measurements at ATLAS and CMS

    CERN Document Server

    McCarthy, Tom; The ATLAS collaboration

    2016-01-01

    The top quark mass ($m_{top}$) is a fundamental parameter of the Standard Model of Particle Physics (SM). As the heaviest of all known SM particles with a mass close to the EW symmetry breaking scale, the top quark plays a pivotal role in the theory of elementary particles. The exact value of the top quark mass has implications on a number of theoretical predictions, which motivates the need for precision measurements of $m_{top}$. This presentation highlights a number of such precision measurements carried out by the ATLAS and CMS collaborations at centre-of-mass energies of $\\sqrt{s}=7$ and $8$ TeV from the combined LHC Run I datasets. A wide range of analysis strategies are employed in a number of channels. Measurements of both the top quark pole mass and $m_{top}$ as defined by the Monte Carlo generator in simulated signal samples are shown. Finally, a summary of combinations of the LHC measurements is presented, together with a look toward top quark mass measurements at $\\sqrt{s}=13$ TeV.

  4. Reliability of in-Shoe Plantar Pressure Measurements in Rheumatoid Arthritis Patients

    Science.gov (United States)

    Vidmar, Gaj; Novak, Primoz

    2009-01-01

    Plantar pressures measurement is a frequently used method in rehabilitation and related research. Metric characteristics of the F-Scan system have been assessed from different standpoints and in different patients, but not its reliability in rheumatoid arthritis patients. Therefore, our objective was to assess reliability of the F-Scan plantar…

  5. Top quark mass measurement at the Tevatron

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes da Costa, Joao; /Harvard U.

    2004-12-01

    The authors report on the latest experimental measurements of the top quark mass by the CDF and D0 Collaborations at the Fermilab Tevatron. They present a new top mass measurement using the t{bar t} events collected by the D0 Collaboration in Run I between 1994 and 1996. This result is combined with previous measurements to yield a new world top mass average. They also describe several preliminary results using up to 193 pb{sup -1} of t{bar t} events produced in {bar p}p collisions at {radical}s = 1.96 TeV during the Run II of the Tevatron.

  6. Inter- and intra-observer reliability of masking in plantar pressure measurement analysis.

    Science.gov (United States)

    Deschamps, K; Birch, I; Mc Innes, J; Desloovere, K; Matricali, G A

    2009-10-01

    Plantar pressure measurement is an important tool in gait analysis. Manual placement of small masks (masking) is increasingly used to calculate plantar pressure characteristics. Little is known concerning the reliability of manual masking. The aim of this study was to determine the reliability of masking on 2D plantar pressure footprints, in a population with forefoot deformity (i.e. hallux valgus). Using a random repeated-measure design, four observers identified the third metatarsal head on a peak-pressure barefoot footprint, using a small mask. Subsequently, the location of all five metatarsal heads was identified, using the same size of masks and the same protocol. The 2D positional variation of the masks and the peak pressure (PP) and pressure time integral (PTI) values of each mask were calculated. For single-masking the lowest inter-observer reliability was found for the distal-proximal direction, causing a clear, adverse impact on the reliability of the pressure characteristics (PP and PTI). In the medial-lateral direction the inter-observer reliability could be scored as high. Intra-observer reliability was better and could be scored as high or good for both directions, with a correlated improved reliability of the pressure characteristics. Reliability of multi-masking showed a similar pattern, but overall values tended to be lower. Therefore, small sized masking in order to define pressure characteristics in the forefoot should be done with care.

  7. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study

    Science.gov (United States)

    West, Jane; Manchester, Ben; Wright, John; Lawlor, Debbie A; Waiblinger, Dagmar

    2011-01-01

    Summary West J, Manchester B, Wright J, Lawlor DA, Waiblinger D. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study. Paediatric and Perinatal Epidemiology 2011. Assessing neonatal size reliably is important for research and clinical practice. The aim of this study was to examine the reliability of routine clinical measurements of neonatal circumferences and of skinfold thicknesses assessed for research purposes. All measurements were undertaken on the same population of neonates born in a large maternity unit in Bradford, UK. Technical error of measurement (TEM), relative TEM and the coefficient of reliability are reported. Intra-observer TEMs for routine circumference measurements were all below 0.4 cm and were generally within ±2-times the mean. Inter-observer TEM ranged from 0.20 to 0.36 cm for head circumference, 0.19 to 0.39 cm for mid upper arm circumference and from 0.39 to 0.77 cm for abdominal circumference. Intra and inter-observer TEM for triceps skinfold thickness ranged from 0.22 to 0.35 mm and 0.15 to 0.54 mm, respectively. Subscapular skinfold thickness TEM values were 0.14 to 0.25 mm for intra-observer measurements and 0.17 to 0.63 mm for inter-observer measurements. Relative TEM values for routine circumferences were all below 4.00% but varied between 2.88% and 14.23% for research skinfold measurements. Reliability was mostly between 80% and 99% for routine circumference measurements and ≥70% for most research skinfold measurements. Routine clinical measurements of neonatal circumferences are reliably assessed in Bradford. Assessing skinfolds in neonates has variable reliability, but on the whole is good. The greater intra-observer, compared with inter-observer, reliability for both sets of measurements highlights the importance of having a minimal number of assessors whenever possible. PMID:21281329

  8. Interferometric diameters of five evolved intermediate-mass planet-hosting stars measured with PAVO at the CHARA Array

    Science.gov (United States)

    White, T. R.; Huber, D.; Mann, A. W.; Casagrande, L.; Grunblatt, S. K.; Justesen, A. B.; Silva Aguirre, V.; Bedding, T. R.; Ireland, M. J.; Schaefer, G. H.; Tuthill, P. G.

    2018-04-01

    Debate over the planet occurrence rates around intermediate-mass stars has hinged on the accurate determination of masses of evolved stars, and has been exacerbated by a paucity of reliable, directly-measured fundamental properties for these stars. We present long-baseline optical interferometry of five evolved intermediate-mass (˜ 1.5 M⊙) planet-hosting stars using the PAVO beam combiner at the CHARA Array, which we combine with bolometric flux measurements and parallaxes to determine their radii and effective temperatures. We measured the radii and effective temperatures of 6 Lyncis (5.12±0.16 R⊙, 4949±58 K), 24 Sextantis (5.49±0.18 R⊙, 4908±65 K), κ Coronae Borealis (4.77±0.07 R⊙, 4870±47 K), HR 6817 (4.45±0.08 R⊙, 5013±59 K), and HR 8641 (4.91±0.12 R⊙, 4950±68 K). We find disagreements of typically 15 % in angular diameter and ˜ 200 K in temperature compared to interferometric measurements in the literature, yet good agreement with spectroscopic and photometric temperatures, concluding that the previous interferometric measurements may have been affected by systematic errors exceeding their formal uncertainties. Modelling based on BaSTI isochrones using various sets of asteroseismic, spectroscopic, and interferometric constraints tends to favour slightly (˜ 15 %) lower masses than generally reported in the literature.

  9. Reliability and validity of non-radiographic methods of thoracic kyphosis measurement: a systematic review.

    Science.gov (United States)

    Barrett, Eva; McCreesh, Karen; Lewis, Jeremy

    2014-02-01

    A wide array of instruments are available for non-invasive thoracic kyphosis measurement. Guidelines for selecting outcome measures for use in clinical and research practice recommend that properties such as validity and reliability are considered. This systematic review reports on the reliability and validity of non-invasive methods for measuring thoracic kyphosis. A systematic search of 11 electronic databases located studies assessing reliability and/or validity of non-invasive thoracic kyphosis measurement techniques. Two independent reviewers used a critical appraisal tool to assess the quality of retrieved studies. Data was extracted by the primary reviewer. The results were synthesized qualitatively using a level of evidence approach. 27 studies satisfied the eligibility criteria and were included in the review. The reliability, validity and both reliability and validity were investigated by sixteen, two and nine studies respectively. 17/27 studies were deemed to be of high quality. In total, 15 methods of thoracic kyphosis were evaluated in retrieved studies. All investigated methods showed high (ICC ≥ .7) to very high (ICC ≥ .9) levels of reliability. The validity of the methods ranged from low to very high. The strongest levels of evidence for reliability exists in support of the Debrunner kyphometer, Spinal Mouse and Flexicurve index, and for validity supports the arcometer and Flexicurve index. Further reliability and validity studies are required to strengthen the level of evidence for the remaining methods of measurement. This should be addressed by future research. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Mass Measurement of Very Short Half-Lived Nuclei

    CERN Document Server

    Duma, M; Iacob, V E; Thibault, C

    2002-01-01

    The MISTRAL (Mass measurements at ISolde with a Transmission RAdiofrequency spectrometer on-Line) experiment exploits a rapid measurement technique to make accurate mass determinations of very short-lived nuclei. The physics goals are to elucidate new nuclear structure effects and constrain nuclear mass models in regions of interest to nuclear astrophysics.\\\\ \\\\The spectrometer, installed in May 97, performed as promised in the proposal with mass resolution exceeding 100,000. In its first experiment in July 1998, neutron-rich Na isotopes having half-lives as short as 31 ms were measured. A second experiment in November 1998 enabled us to improve the measurement precision of the isotopes $^{26-30}$Na to about 20 keV. The measurement program continues as experiment IS 373.

  11. Precision measurement of $D$ meson mass differences

    CERN Document Server

    INSPIRE-00258707; Abellan Beteta, C; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves Jr, A A; Amato, S; Amerio, S; Amhis, Y; Anderlini, L; Anderson, J; Andreassen, R; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Baesso, C; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bauer, Th; Bay, A; Beddow, J; Bedeschi, F; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Berezhnoy, A; Bernet, R; Bettler, M -O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blouw, J; Blusk, S; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bowen, E; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Brown, H; Burducea, I; Bursche, A; Busetto, G; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Campora Perez, D; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carranza-Mejia, H; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Cauet, Ch; Charles, M; Charpentier, Ph; Chen, P; Chiapolini, N; Chrzaszcz, M; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Cogneras, E; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombes, M; Coquereau, S; Corti, G; Couturier, B; Cowan, G A; Craik, D C; Cunliffe, S; Currie, R; D'Ambrosio, C; David, P; David, P N Y; Davis, A; De Bonis, I; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Silva, W; De Simone, P; Decamp, D; Deckenhoff, M; Del Buono, L; Derkach, D; Deschamps, O; Dettori, F; Di Canto, A; Dijkstra, H; Dogaru, M; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; El Rifai, I; Elsasser, Ch; Elsby, D; Falabella, A; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Ferguson, D; Fernandez Albor, V; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fiore, M; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Furcas, S; Furfaro, E; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garofoli, J; Garosi, P; Garra Tico, J; Garrido, L; Gaspar, C; Gauld, R; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Grünberg, O; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hampson, T; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; Hartmann, T; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Hill, D; Hoballah, M; Hombach, C; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Hussain, N; Hutchcroft, D; Hynds, D; Iakovenko, V; Idzik, M; Ilten, P; Jacobsson, R; Jaeger, A; Jans, E; Jaton, P; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kaballo, M; Kandybei, S; Karacson, M; Karbach, T M; Kenyon, I R; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kochebina, O; Komarov, I; Koopman, R F; Koppenburg, P; Korolev, M; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kucharczyk, M; Kudryavtsev, V; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J -P; Lefèvre, R; Leflat, A; Lefrançois, J; Leo, S; Leroy, O; Lesiak, T; Leverington, B; Li, Y; Li Gioi, L; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lohn, S; Longstaff, I; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Lu, H; Lucchesi, D; Luisier, J; Luo, H; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Malde, S; Manca, G; Mancinelli, G; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinelli, M; Martinez Santos, D; Martins Tostes, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Maurice, E; Mazurov, A; McCarthy, J; McNab, A; McNulty, R; Meadows, B; Meier, F; Meissner, M; Merk, M; Milanes, D A; Minard, M -N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Morello, M J; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Needham, M; Neufeld, N; Nguyen, A D; Nguyen, T D; Nguyen-Mau, C; Nicol, M; Niess, V; Niet, R; Nikitin, N; Nikodem, T; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Oyanguren, A; Pal, B K; Palano, A; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petridis, K; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pietrzyk, B; Pilař, T; Pinci, D; Playfer, S; Plo Casasus, M; Polci, F; Polok, G; Poluektov, A; Polycarpo, E; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pugatch, V; Puig Navarro, A; Punzi, G; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Rauschmayr, N; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Richards, A; Rinnert, K; Rives Molina, V; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodriguez Perez, P; Roiser, S; Romanovsky, V; Romero Vidal, A; Rouvinet, J; Ruf, T; Ruffini, F; Ruiz, H; Ruiz Valls, P; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salzmann, C; Sanmartin Sedes, B; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schindler, H; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skwarnicki, T; Smith, N A; Smith, E; Smith, M; Sokoloff, M D; Soler, F J P; Soomro, F; Souza, D; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Swientek, S; Syropoulos, V; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teklishyn, M; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Tolk, S; Tonelli, D; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Tran, M T; Tresch, M; Tsaregorodtsev, A; Tsopelas, P; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urner, D; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Veneziano, G; Vesterinen, M; Viaud, B; Vieira, D; Vilasis-Cardona, X; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Vorobyev, V; Voß, C; Voss, H; Waldi, R; Wallace, R; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wicht, J; Wiechczynski, J; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Wotton, S A; Wright, S; Wu, S; Wyllie, K; Xie, Y; Xing, F; Xing, Z; Yang, Z; Young, R; Yuan, X; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhokhov, A; Zhong, L; Zvyagin, A

    2013-01-01

    Using three- and four-body decays of $D$ mesons produced in semileptonic $b$-hadron decays, precision measurements of $D$ meson mass differences are made together with a measurement of the $D^{0}$ mass. The measurements are based on a dataset corresponding to an integrated luminosity of 1.0 fb$^{-1}$ collected in $pp$ collisions at 7~TeV. Using the decay $D^0 \\rightarrow K^{+} K^{-} K^{-} \\pi^{+}$, the $D^0$ mass is measured to be \\begin{alignat*}{3} M(D^0) \\phantom{ghd} &=&~1864.75 \\pm 0.15 \\,({\\rm stat}) \\pm 0.11 \\,({\\rm syst}) \\, \\textrm{MeV}/c^2. \\end{alignat*} The mass differences \\begin{alignat*}{3} M(D^{+}) - M(D^{0}) &=& 4.76 \\pm 0.12 \\,({\\rm stat}) \\pm 0.07 \\,({\\rm syst}) \\, \\textrm{MeV}/c^2, \\\\ M(D^{+}_s) - M(D^{+}) &=& \\phantom{00}98.68 \\pm 0.03 \\,({\\rm stat}) \\pm 0.04 \\,({\\rm syst}) \\, \\textrm{MeV}/c^2 \\end{alignat*} are measured using the $D^0 \\rightarrow K^{+} K^{-} \\pi^{+} \\pi^{-}$ and $D^{+}_{(s)} \\rightarrow K^{+}K^{-} \\pi^{+}$ modes.

  12. The gothic arch: a reliable measurement for developmental dysplasia of the hip.

    Science.gov (United States)

    Herickhoff, Paul K; O'Brien, Megan K; Dolan, Lori A; Morcuende, Jose A; Peterson, Jonathan B; Weinstein, Stuart L

    2013-01-01

    The "Gothic Arch" is a radio-graphic finding on AP pelvis x-rays postulated to be predictive of hip osteoarthritis. The purpose of this study was to determine the reliability of measurement of the Gothic Arch in patients with no known hip pathology and patients with unilateral developmental dysplasia of the hip (DDH). After obtaining IRB approval, nine skeletally mature patients (18 hips) with no known hip pathology were selected to serve as the control group. The AP pelvis x-rays at skeletal maturity of eight patients (16 hips) with unilateral DDH treated with closed reduction and casting comprised the comparison group. A digitizing program was designed to measure the Gothic Arch based on landmarks identified by the user. Two pediatric orthopaedic surgeons and two orthopaedic residents completed the program on two separate occasions. Intra-and interobserver reliability were determined using intraclass cor-relation coefficients (ICC) for continuous variables. Both the unilateral DDH group and the control group demonstrated excellent inter- and intraobserver reliability (ICC >0.70) for base, height, area, and orientation of the Gothic Arch, but poor reliability (ICC Gothic Arch can be reliably measured on AP pelvis x-rays of patients with normal and dysplastic hips. III, Diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.

  13. Validity and reliability of food security measures.

    Science.gov (United States)

    Cafiero, Carlo; Melgar-Quiñonez, Hugo R; Ballard, Terri J; Kepple, Anne W

    2014-12-01

    This paper reviews some of the existing food security indicators, discussing the validity of the underlying concept and the expected reliability of measures under reasonably feasible conditions. The main objective of the paper is to raise awareness on existing trade-offs between different qualities of possible food security measurement tools that must be taken into account when such tools are proposed for practical application, especially for use within an international monitoring framework. The hope is to provide a timely, useful contribution to the process leading to the definition of a food security goal and the associated monitoring framework within the post-2015 Development Agenda. © 2014 New York Academy of Sciences.

  14. Insightful practice: a reliable measure for medical revalidation

    Science.gov (United States)

    Guthrie, Bruce; Sullivan, Frank M; Mercer, Stewart W; Russell, Andrew; Bruce, David A

    2012-01-01

    Background Medical revalidation decisions need to be reliable if they are to reassure on the quality and safety of professional practice. This study tested an innovative method in which general practitioners (GPs) were assessed on their reflection and response to a set of externally specified feedback. Setting and participants 60 GPs and 12 GP appraisers in the Tayside region of Scotland, UK. Methods A feedback dataset was specified as (1) GP-specific data collected by GPs themselves (patient and colleague opinion; open book self-evaluated knowledge test; complaints) and (2) Externally collected practice-level data provided to GPs (clinical quality and prescribing safety). GPs' perceptions of whether the feedback covered UK General Medical Council specified attributes of a ‘good doctor’ were examined using a mapping exercise. GPs' professionalism was examined in terms of appraiser assessment of GPs' level of insightful practice, defined as: engagement with, insight into and appropriate action on feedback data. The reliability of assessment of insightful practice and subsequent recommendations on GPs' revalidation by face-to-face and anonymous assessors were investigated using Generalisability G-theory. Main outcome measures Coverage of General Medical Council attributes by specified feedback and reliability of assessor recommendations on doctors' suitability for revalidation. Results Face-to-face assessment proved unreliable. Anonymous global assessment by three appraisers of insightful practice was highly reliable (G=0.85), as were revalidation decisions using four anonymous assessors (G=0.83). Conclusions Unlike face-to-face appraisal, anonymous assessment of insightful practice offers a valid and reliable method to decide GP revalidation. Further validity studies are needed. PMID:22653078

  15. First mass measurements at LHCb

    CERN Multimedia

    Bressieux, J

    2011-01-01

    The LHC opens new frontiers in heavy flavour physics through an unprecedented statistical reach for a variety of interesting states produced in pp collisions. The LHCb spectrometer provides a good mass resolution and is suitable for spectroscopy studies. We present first preliminary mass measurements of several $b$ hadrons and of the exotic $X(3872)$ meson, reconstructed in final states containing a $J/\\psi$ using the data collected in 2010 by the LHCb experiment. An important aspect of the analysis is the calibration of the momentum scale using $J/\\psi \\to \\mu^+ \\mu^-$ decays, as well as the control of systematic uncertainties. While the already very competitive mass measurements for the $B^+$, $B^0$ and $B^0_s$ mesons receive similar contributions from systematic and statistical uncertainties, those of the $\\Lambda_b$, $B^+_c$ and $X(3872)$ particles are dominated by statistical uncertainties, and will therefore substantially improve with more data in the future.

  16. Efficiency criteria for high reliability measured system structures

    International Nuclear Information System (INIS)

    Sal'nikov, N.L.

    2012-01-01

    The procedures of structural redundancy are usually used to develop high reliability measured systems. To estimate efficiency of such structures the criteria to compare different systems has been developed. So it is possible to develop more exact system by inspection of redundant system data unit stochastic characteristics in accordance with the developed criteria [ru

  17. Cosmological and astrophysical neutrino mass measurements

    DEFF Research Database (Denmark)

    Abazajian, K.N.; Calabrese, E.; Cooray, A.

    2011-01-01

    Cosmological and astrophysical measurements provide powerful constraints on neutrino masses complementary to those from accelerators and reactors. Here we provide a guide to these different probes, for each explaining its physical basis, underlying assumptions, current and future reach.......Cosmological and astrophysical measurements provide powerful constraints on neutrino masses complementary to those from accelerators and reactors. Here we provide a guide to these different probes, for each explaining its physical basis, underlying assumptions, current and future reach....

  18. Reliability generalization of the Multigroup Ethnic Identity Measure-Revised (MEIM-R).

    Science.gov (United States)

    Herrington, Hayley M; Smith, Timothy B; Feinauer, Erika; Griner, Derek

    2016-10-01

    [Correction Notice: An Erratum for this article was reported in Vol 63(5) of Journal of Counseling Psychology (see record 2016-33161-001). The name of author Erika Feinauer was misspelled as Erika Feinhauer. All versions of this article have been corrected.] Individuals' strength of ethnic identity has been linked with multiple positive indicators, including academic achievement and overall psychological well-being. The measure researchers use most often to assess ethnic identity, the Multigroup Ethnic Identity Measure (MEIM), underwent substantial revision in 2007. To inform scholars investigating ethnic identity, we performed a reliability generalization analysis on data from the revised version (MEIM-R) and compared it with data from the original MEIM. Random-effects weighted models evaluated internal consistency coefficients (Cronbach's alpha). Reliability coefficients for the MEIM-R averaged α = .88 across 37 samples, a statistically significant increase over the average of α = .84 for the MEIM across 75 studies. Reliability coefficients for the MEIM-R did not differ across study and participant characteristics such as sample gender and ethnic composition. However, consistently lower reliability coefficients averaging α = .81 were found among participants with low levels of education, suggesting that greater attention to data reliability is warranted when evaluating the ethnic identity of individuals such as middle-school students. Future research will be needed to ascertain whether data with other measures of aspects of personal identity (e.g., racial identity, gender identity) also differ as a function of participant level of education and associated cognitive or maturation processes. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  19. W Boson Mass Measurement at CDF

    Energy Technology Data Exchange (ETDEWEB)

    Kotwal, Ashutosh V. [Duke Univ., Durham, NC (United States). Physics Dept.

    2017-03-27

    This is the closeout report for the grant for experimental research at the energy frontier in high energy physics. The report describes the precise measurement of the W boson mass at the CDF experiment at Fermilab, with an uncertainty of ≈ 12 MeV, using the full dataset of ≈ 9 fb-1 collected by the experiment up to the shutdown of the Tevatron in 2011. In this analysis, the statistical and most of the experimental systematic uncertainties have been reduced by a factor of two compared to the previous measurement with 2.2 fb-1 of CDF data. This research has been the culmination of the PI's track record of producing world-leading measurements of the W boson mass from the Tevatron. The PI performed the first and only measurement to date of the W boson mass using high-rapidity leptons using the D0 endcap calorimeters in Run 1. He has led this measurement in Run 2 at CDF, publishing two world-leading measurements in 2007 and 2012 with total uncertainties of 48 MeV and 19 MeV respectively. The analysis of the final dataset is currently under internal review in CDF. Upon approval of the internal review, the result will be available for public release.

  20. Characterization of perovskite solar cells: Towards a reliable measurement protocol

    Directory of Open Access Journals (Sweden)

    Eugen Zimmermann

    2016-09-01

    Full Text Available Lead halide perovskite solar cells have shown a tremendous rise in power conversion efficiency with reported record efficiencies of over 20% making this material very promising as a low cost alternative to conventional inorganic solar cells. However, due to a differently severe “hysteretic” behaviour during current density-voltage measurements, which strongly depends on scan rate, device and measurement history, preparation method, device architecture, etc., commonly used solar cell measurements do not give reliable or even reproducible results. For the aspect of commercialization and the possibility to compare results of different devices among different laboratories, it is necessary to establish a measurement protocol which gives reproducible results. Therefore, we compare device characteristics derived from standard current density-voltage measurements with stabilized values obtained from an adaptive tracking of the maximum power point and the open circuit voltage as well as characteristics extracted from time resolved current density-voltage measurements. Our results provide insight into the challenges of a correct determination of device performance and propose a measurement protocol for a reliable characterisation which is easy to implement and has been tested on varying perovskite solar cells fabricated in different laboratories.

  1. Improving Metrological Reliability of Information-Measuring Systems Using Mathematical Modeling of Their Metrological Characteristics

    Science.gov (United States)

    Kurnosov, R. Yu; Chernyshova, T. I.; Chernyshov, V. N.

    2018-05-01

    The algorithms for improving the metrological reliability of analogue blocks of measuring channels and information-measuring systems are developed. The proposed algorithms ensure the optimum values of their metrological reliability indices for a given analogue circuit block solution.

  2. Measurement of the W mass at LEP 200

    International Nuclear Information System (INIS)

    Bijnens, J.; Zeppenfeld, D.; Kunszt, Z.

    1987-01-01

    Each of the four LEP experiments can measure in at least three ways the mass of the W boson at LEP 200 with an accuracy of the order of 100 MeV (or better). W mass measurement from the threshold behavior of σ (e + e - →W + W - ), W mass reconstruction using the W decay products, and W mass reconstruction from the end point of the lepton energy spectrum. The integrated luminosity of 500 events/pb used in this study provides a better statistical accuracy (50-60 MeV) but it appears difficult to control the systematical uncertainties at such a level. All the methods proposed in this report require the knowledge of the machine beam energy which gives in any case an absolute limit on the W mass measurement accuracy. Then, the theoretical interest in measuring M W at the 1 o/oo level is discussed. 22 figs; 25 refs

  3. Comparison of reliability and responsiveness of patient-reported clinical outcome measures in knee osteoarthritis rehabilitation.

    Science.gov (United States)

    Williams, Valerie J; Piva, Sara R; Irrgang, James J; Crossley, Chad; Fitzgerald, G Kelley

    2012-08-01

    Secondary analysis, pretreatment-posttreatment observational study. To compare the reliability and responsiveness of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Knee Outcome Survey activities of daily living subscale (KOS-ADL), and the Lower Extremity Functional Scale (LEFS) in individuals with knee osteoarthritis (OA). The WOMAC is the current standard in patient-reported measures of function in patients with knee OA. The KOS-ADL and LEFS were designed for potential use in patients with knee OA. If the KOS-ADL and LEFS are to be considered viable alternatives to the WOMAC for measuring patient-reported function in individuals with knee OA, they should have measurement properties comparable to the WOMAC. It would also be important to determine whether either of these instruments may be superior to the WOMAC in terms of reliability or responsiveness in this population. Data from 168 subjects with knee OA, who participated in a rehabilitation program, were used in the analyses. Reliability and responsiveness of each outcome measure were estimated at follow-ups of 2, 6, and 12 months. Reliability was estimated by calculating the intraclass correlation coefficient (ICC2,1) for subjects who were unchanged in status from baseline at each follow-up time, based on a global rating of change score. To examine responsiveness, the standard error of the measurement, minimal detectable change, minimal clinically important difference, and the Guyatt responsiveness index were calculated for each outcome measure at each follow-up time. All 3 outcome measures demonstrated reasonable reliability and responsiveness to change. Reliability and responsiveness tended to decrease somewhat with increasing follow-up time. There were no substantial differences between outcome measures for reliability or any of the 3 measures of responsiveness at any follow-up time. The results do not indicate that one outcome measure is more reliable or responsive than

  4. A Reliable Measure of Information Security Awareness and the Identification of Bias in Responses

    Directory of Open Access Journals (Sweden)

    Agata McCormac

    2017-11-01

    Full Text Available The Human Aspects of Information Security Questionnaire (HAIS-Q is designed to measure Information Security Awareness. More specifically, the tool measures an individual’s knowledge, attitude, and self-reported behaviour relating to information security in the workplace. This paper reports on the reliability of the HAIS-Q, including test-retest reliability and internal consistency. The paper also assesses the reliability of three preliminary over-claiming items, designed specifically to complement the HAIS-Q, and identify those individuals who provide socially desirable responses. A total of 197 working Australians completed two iterations of the HAIS-Q and the over-claiming items, approximately 4 weeks apart. Results of the analysis showed that the HAIS-Q was externally reliable and internally consistent. Therefore, the HAIS-Q can be used to reliably measure information security awareness. Reliability testing on the preliminary over-claiming items was not as robust and further development is required and recommended. The implications of these findings mean that organisations can confidently use the HAIS-Q to not only measure the current state of employee information security awareness within their organisation, but they can also measure the effectiveness and impacts of training interventions, information security awareness programs and campaigns. The influence of cultural changes and the effect of security incidents can also be assessed.

  5. Modeling reliability measurement of interface on information system: Towards the forensic of rules

    Science.gov (United States)

    Nasution, M. K. M.; Sitompul, Darwin; Harahap, Marwan

    2018-02-01

    Today almost all machines depend on the software. As a software and hardware system depends also on the rules that are the procedures for its use. If the procedure or program can be reliably characterized by involving the concept of graph, logic, and probability, then regulatory strength can also be measured accordingly. Therefore, this paper initiates an enumeration model to measure the reliability of interfaces based on the case of information systems supported by the rules of use by the relevant agencies. An enumeration model is obtained based on software reliability calculation.

  6. Improved reliability of wind turbine towers with active tuned mass dampers (ATMDs)

    Science.gov (United States)

    Fitzgerald, Breiffni; Sarkar, Saptarshi; Staino, Andrea

    2018-04-01

    Modern multi-megawatt wind turbines are composed of slender, flexible, and lightly damped blades and towers. These components exhibit high susceptibility to wind-induced vibrations. As the size, flexibility and cost of the towers have increased in recent years, the need to protect these structures against damage induced by turbulent aerodynamic loading has become apparent. This paper combines structural dynamic models and probabilistic assessment tools to demonstrate improvements in structural reliability when modern wind turbine towers are equipped with active tuned mass dampers (ATMDs). This study proposes a multi-modal wind turbine model for wind turbine control design and analysis. This study incorporates an ATMD into the tower of this model. The model is subjected to stochastically generated wind loads of varying speeds to develop wind-induced probabilistic demand models for towers of modern multi-megawatt wind turbines under structural uncertainty. Numerical simulations have been carried out to ascertain the effectiveness of the active control system to improve the structural performance of the wind turbine and its reliability. The study constructs fragility curves, which illustrate reductions in the vulnerability of towers to wind loading owing to the inclusion of the damper. Results show that the active controller is successful in increasing the reliability of the tower responses. According to the analysis carried out in this paper, a strong reduction of the probability of exceeding a given displacement at the rated wind speed has been observed.

  7. Reliability assessment for thickness measurements of pipe wall using probability of detection

    International Nuclear Information System (INIS)

    Nakamoto, Hiroyuki; Kojima, Fumio; Kato, Sho

    2013-01-01

    This paper proposes a reliability assessment method for thickness measurements of pipe wall using probability of detection (POD). Thicknesses of pipes are measured by qualified inspectors with ultrasonic thickness gauges. The inspection results are affected by human factors of the inspectors and include some errors, because the inspectors have different experiences and frequency of inspections. In order to ensure reliability for inspection results, first, POD evaluates experimental results of pipe-wall thickness inspection. We verify that the results have differences depending on inspectors including qualified inspectors. Second, two human factors that affect POD are indicated. Finally, it is confirmed that POD can identify the human factors and ensure reliability for pipe-wall thickness inspections. (author)

  8. Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements

    Directory of Open Access Journals (Sweden)

    Natalia M. Martinho

    2015-04-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the intra and inter-rater reliability of pelvic floor muscle (PFM dynamometric measurements for maximum and average strengths, as well as endurance. METHOD: A convenience sample of 18 nulliparous women, without any urogynecological complaints, aged between 19 and 31 (mean age of 25.4±3.9 participated in this study. They were evaluated using a pelvic floor dynamometer based on load cell technology. The dynamometric evaluations were repeated in three successive sessions: two on the same day with a rest period of 30 minutes between them, and the third on the following day. All participants were evaluated twice in each session; first by examiner 1 followed by examiner 2. The vaginal dynamometry data were analyzed using three parameters: maximum strength, average strength, and endurance. The Intraclass Correlation Coefficient (ICC was applied to estimate the PFM dynamometric measurement reliability, considering a good level as being above 0.75. RESULTS: The intra and inter-raters' analyses showed good reliability for maximum strength (ICCintra-rater1=0.96, ICCintra-rater2=0.95, and ICCinter-rater=0.96, average strength (ICCintra-rater1=0.96, ICCintra-rater2=0.94, and ICCinter-rater=0.97, and endurance (ICCintra-rater1=0.88, ICCintra-rater2=0.86, and ICCinter-rater=0.92 dynamometric measurements. CONCLUSIONS: The PFM dynamometric measurements showed good intra- and inter-rater reliability for maximum strength, average strength and endurance, which demonstrates that this is a reliable device that can be used in clinical practice.

  9. Concurrent validity and reliability of torso-worn inertial measurement unit for jump power and height estimation.

    Science.gov (United States)

    Rantalainen, Timo; Gastin, Paul B; Spangler, Rhys; Wundersitz, Daniel

    2018-09-01

    The purpose of the present study was to evaluate the concurrent validity and test-retest repeatability of torso-worn IMU-derived power and jump height in a counter-movement jump test. Twenty-seven healthy recreationally active males (age, 21.9 [SD 2.0] y, height, 1.76 [0.7] m, mass, 73.7 [10.3] kg) wore an IMU and completed three counter-movement jumps a week apart. A force platform and a 3D motion analysis system were used to concurrently measure the jumps and subsequently derive power and jump height (based on take-off velocity and flight time). The IMU significantly overestimated power (mean difference = 7.3 W/kg; P jump heights exhibited poorer concurrent validity (ICC = 0.72 to 0.78) and repeatability (ICC = 0.68) than flight-time-derived jump heights, which exhibited excellent validity (ICC = 0.93 to 0.96) and reliability (ICC = 0.91). Since jump height and power are closely related, and flight-time-derived jump height exhibits excellent concurrent validity and reliability, flight-time-derived jump height could provide a more desirable measure compared to power when assessing athletic performance in a counter-movement jump with IMUs.

  10. Can Reliability of Multiple Component Measuring Instruments Depend on Response Option Presentation Mode?

    Science.gov (United States)

    Menold, Natalja; Raykov, Tenko

    2016-01-01

    This article examines the possible dependency of composite reliability on presentation format of the elements of a multi-item measuring instrument. Using empirical data and a recent method for interval estimation of group differences in reliability, we demonstrate that the reliability of an instrument need not be the same when polarity of the…

  11. Characterization of a catalyst-based conversion technique to measure total particulate nitrogen and organic carbon and comparison to a particle mass measurement instrument

    Science.gov (United States)

    Stockwell, Chelsea E.; Kupc, Agnieszka; Witkowski, Bartłomiej; Talukdar, Ranajit K.; Liu, Yong; Selimovic, Vanessa; Zarzana, Kyle J.; Sekimoto, Kanako; Warneke, Carsten; Washenfelder, Rebecca A.; Yokelson, Robert J.; Middlebrook, Ann M.; Roberts, James M.

    2018-05-01

    electrospray ionization source of a quadrupole mass spectrometer (PILS-ESI/MS) sampling in the negative-ion mode. We obtain excellent correlations (R2 = 0.99) of particle mass measured as Nr with PILS-ESI/MS measurements converted to the corresponding particle anion mass (e.g., nitrate, sulfate, and chloride). The Nr and PILS-ESI/MS are shown to agree to within ˜ 6 % for particle mass loadings of up to 120 µg m-3. Consideration of all the sources of error in the PILS-ESI/MS technique yields an overall uncertainty of ±20 % for these single-component particle streams. These results demonstrate the Nr system is a reliable direct particle mass measurement technique that differs from other particle instrument calibration techniques that rely on knowledge of particle size, shape, density, and refractive index.

  12. Top Quark Mass Measurement in Dilepton Channel

    Energy Technology Data Exchange (ETDEWEB)

    Lysak, Roman [Inst. of Experimental Physics, Kosice (Slovak Republic)

    2007-06-01

    We present a measurement of the top quark mass from events produced in p$\\bar{p}$ collisions at a center-of-mass energy of 1.96 TeV, using the Collider Detector at Fermilab. We identify t$\\bar{t}$ candidates where both W bosons from the top quarks decay into leptons (eν, µν, τν) from a data sample of 340 pb-1. The top quark mass is reconstructed in each event separately by the method which draw upon simulated distribution of t$\\bar{t}$ longitudinal momentum in order to extract probability distribution for the top quark mass. Representative distributions, or templates, are constructed from simulated samples of signal and background events, and parametrized to form continuous probability density functions. A likelihood fit incorporating these parametrized templates is then performed on the data sample masses in order to derive a final top quark mass. Measured top quark mass is Mtop = 169.5$+7.7\\atop{-7.2}$(stat.) ± 4.0(syst.) GeV/c2.

  13. Reliable Portfolio Selection Problem in Fuzzy Environment: An mλ Measure Based Approach

    Directory of Open Access Journals (Sweden)

    Yuan Feng

    2017-04-01

    Full Text Available This paper investigates a fuzzy portfolio selection problem with guaranteed reliability, in which the fuzzy variables are used to capture the uncertain returns of different securities. To effectively handle the fuzziness in a mathematical way, a new expected value operator and variance of fuzzy variables are defined based on the m λ measure that is a linear combination of the possibility measure and necessity measure to balance the pessimism and optimism in the decision-making process. To formulate the reliable portfolio selection problem, we particularly adopt the expected total return and standard variance of the total return to evaluate the reliability of the investment strategies, producing three risk-guaranteed reliable portfolio selection models. To solve the proposed models, an effective genetic algorithm is designed to generate the approximate optimal solution to the considered problem. Finally, the numerical examples are given to show the performance of the proposed models and algorithm.

  14. Test-retest reliability of behavioral measures of impulsive choice, impulsive action, and inattention.

    Science.gov (United States)

    Weafer, Jessica; Baggott, Matthew J; de Wit, Harriet

    2013-12-01

    Behavioral measures of impulsivity are widely used in substance abuse research, yet relatively little attention has been devoted to establishing their psychometric properties, especially their reliability over repeated administration. The current study examined the test-retest reliability of a battery of standardized behavioral impulsivity tasks, including measures of impulsive choice (i.e., delay discounting, probability discounting, and the Balloon Analogue Risk Task), impulsive action (i.e., the stop signal task, the go/no-go task, and commission errors on the continuous performance task), and inattention (i.e., attention lapses on a simple reaction time task and omission errors on the continuous performance task). Healthy adults (n = 128) performed the battery on two separate occasions. Reliability estimates for the individual tasks ranged from moderate to high, with Pearson correlations within the specific impulsivity domains as follows: impulsive choice (r range: .76-.89, ps reliable measures and thus can be confidently used to assess various facets of impulsivity as intermediate phenotypes for drug abuse.

  15. Relating measurement invariance, cross-level invariance, and multilevel reliability

    NARCIS (Netherlands)

    Jak, S.; Jorgensen, T.D.

    2017-01-01

    Data often have a nested, multilevel structure, for example when data are collected from children in classrooms. This kind of data complicate the evaluation of reliability and measurement invariance, because several properties can be evaluated at both the individual level and the cluster level, as

  16. Reliability analysis framework for computer-assisted medical decision systems

    International Nuclear Information System (INIS)

    Habas, Piotr A.; Zurada, Jacek M.; Elmaghraby, Adel S.; Tourassi, Georgia D.

    2007-01-01

    We present a technique that enhances computer-assisted decision (CAD) systems with the ability to assess the reliability of each individual decision they make. Reliability assessment is achieved by measuring the accuracy of a CAD system with known cases similar to the one in question. The proposed technique analyzes the feature space neighborhood of the query case to dynamically select an input-dependent set of known cases relevant to the query. This set is used to assess the local (query-specific) accuracy of the CAD system. The estimated local accuracy is utilized as a reliability measure of the CAD response to the query case. The underlying hypothesis of the study is that CAD decisions with higher reliability are more accurate. The above hypothesis was tested using a mammographic database of 1337 regions of interest (ROIs) with biopsy-proven ground truth (681 with masses, 656 with normal parenchyma). Three types of decision models, (i) a back-propagation neural network (BPNN), (ii) a generalized regression neural network (GRNN), and (iii) a support vector machine (SVM), were developed to detect masses based on eight morphological features automatically extracted from each ROI. The performance of all decision models was evaluated using the Receiver Operating Characteristic (ROC) analysis. The study showed that the proposed reliability measure is a strong predictor of the CAD system's case-specific accuracy. Specifically, the ROC area index for CAD predictions with high reliability was significantly better than for those with low reliability values. This result was consistent across all decision models investigated in the study. The proposed case-specific reliability analysis technique could be used to alert the CAD user when an opinion that is unlikely to be reliable is offered. The technique can be easily deployed in the clinical environment because it is applicable with a wide range of classifiers regardless of their structure and it requires neither additional

  17. Reliability and Minimum Detectable Change of Temporal-Spatial, Kinematic, and Dynamic Stability Measures during Perturbed Gait.

    Directory of Open Access Journals (Sweden)

    Christopher A Rábago

    Full Text Available Temporal-spatial, kinematic variability, and dynamic stability measures collected during perturbation-based assessment paradigms are often used to identify dysfunction associated with gait instability. However, it remains unclear which measures are most reliable for detecting and tracking responses to perturbations. This study systematically determined the between-session reliability and minimum detectable change values of temporal-spatial, kinematic variability, and dynamic stability measures during three types of perturbed gait. Twenty young healthy adults completed two identical testing sessions two weeks apart, comprised of an unperturbed and three perturbed (cognitive, physical, and visual walking conditions in a virtual reality environment. Within each session, perturbation responses were compared to unperturbed walking using paired t-tests. Between-session reliability and minimum detectable change values were also calculated for each measure and condition. All temporal-spatial, kinematic variability and dynamic stability measures demonstrated fair to excellent between-session reliability. Minimal detectable change values, normalized to mean values ranged from 1-50%. Step width mean and variability measures demonstrated the greatest response to perturbations with excellent between-session reliability and low minimum detectable change values. Orbital stability measures demonstrated specificity to perturbation direction and sensitivity with excellent between-session reliability and low minimum detectable change values. We observed substantially greater between-session reliability and lower minimum detectable change values for local stability measures than previously described which may be the result of averaging across trials within a session and using velocity versus acceleration data for reconstruction of state spaces. Across all perturbation types, temporal-spatial, orbital and local measures were the most reliable measures with the

  18. Measuring walking within and outside the neighborhood in Chinese elders: reliability and validity

    Directory of Open Access Journals (Sweden)

    Cerin Ester

    2011-11-01

    Full Text Available Abstract Background Walking is a preferred, prevalent and recommended activity for aging populations and is influenced by the neighborhood built environment. To study this influence it is necessary to differentiate whether walking occurs within or outside of the neighborhood. The Neighborhood Physical Activity Questionnaire (NPAQ collects information on setting-specific physical activity, including walking, inside and outside one's neighborhood. While the NPAQ has shown to be a reliable measure in adults, its reliability in older adults is unknown. Additionally its validity and the influence of type of neighborhood on reliability and validity have yet to be explored. Methods The NPAQ walking component was adapted for Chinese speaking elders (NWQ-CS. Ninety-six Chinese elders, stratified by social economic status and neighborhood walkability, wore an accelerometer and completed a log of walks for 7 days. Following the collection of valid data the NWQ-CS was interviewer-administered. Fourteen to 20 days (average of 17 days later the NWQ-CS was re-administered. Test-retest reliability and validity of the NWQ-CS were assessed. Results Reliability and validity estimates did not differ with type of neighborhood. NWQ-CS measures of walking showed moderate to excellent reliability. Reliability was generally higher for estimates of weekly frequency than minutes of walking. Total weekly minutes of walking were moderately related to all accelerometry measures. Moderate-to-strong associations were found between the NWQ-CS and log-of-walks variables. The NWQ-CS yielded statistically significantly lower mean values of total walking, weekly minutes of walking for transportation and weekly frequency of walking for transportation outside the neighborhood than the log-of-walks. Conclusions The NWQ-CS showed measurement invariance across types of neighborhoods. It is a valid measure of walking for recreation and frequency of walking for transport. However, it may

  19. Techniques, processes, and measures for software safety and reliability

    International Nuclear Information System (INIS)

    Sparkman, D.

    1992-01-01

    The purpose of this report is to provide a detailed survey of current recommended practices and measurement techniques for the development of reliable and safe software-based systems. This report is intended to assist the United States Nuclear Reaction Regulation (NRR) in determining the importance and maturity of the available techniques and in assessing the relevance of individual standards for application to instrumentation and control systems in nuclear power generating stations. Lawrence Livermore National Laboratory (LLNL) provides technical support for the Instrumentation and Control System Branch (ICSB) of NRRin advanced instrumentation and control systems, distributed digital systems, software reliability, and the application of verificafion and validafion for the development of software

  20. A clinical tool to measure plagiocephaly in infants using a flexicurve: a reliability study

    Directory of Open Access Journals (Sweden)

    Leung A

    2013-10-01

    Full Text Available Amy Leung,1 Pauline Watter,2 John Gavranich3 1Department of Physiotherapy, Royal Children's Hospital, Brisbane, Australia; 2Physiotherapy Division, University of Queensland, Brisbane, Australia; 3Child and Family Health Services, West Moreton Health Service District, Ipswich, Australia Purpose: There has been an increasing incidence of infants presenting with plagiocephaly in the last two decades. A practical, economical, and reliable clinical plagiocephaly measure is essential to assess progression and intervention outcomes. This study investigated the reliability of a modified cranial vault asymmetry index using a flexible curve in infants. Measurement: A flexicurve was molded to the infant's head and its shape maintained as it was placed onto paper to trace the head shape. Using a small modification of Loveday and De Chaplain's procedure to measure a cranial vault asymmetry index, a pair of diagonals were drawn at 30° through the midpoint of the central line to their intersection with the traced head outline. The difference in length of the paired diagonals was divided by the short diameter then multiplied by 100%, yielding the modified cranial vault-asymmetry index. Patients and methods: Infants referred to a community health physiotherapist for assessment due to suspected abnormal head shape were included. To explore intrarater reliability, 34 infants aged 3–14 months were measured twice (T1/T1′ at the beginning, and 21 of these remeasured twice at the end (T2/T2′ of their physiotherapy sessions. Test–retest reliability used matched-average data (T1/T1′ and (T2/T2′ from 21 infants. To explore interrater reliability, 18 healthy infants aged 2–6 months were recruited. Each infant was measured once by each rater. Results: For intrarater reliability, the intraclass correlation coefficient with 54 degrees of freedom (ICCdf54 was 0.868 (95% confidence interval [CI] 0.783–0.921; for test–retest reliability, ICCdf20 = 0.958 (95

  1. Fat mass measured by DXA varies with scan velocity

    DEFF Research Database (Denmark)

    Black, Eva; Petersen, Liselotte; Kreutzer, Martin

    2002-01-01

    To study the influence of scan velocities of DXA on the measured size of fat mass, lean body mass, bone mineral content and density, and total body weight.......To study the influence of scan velocities of DXA on the measured size of fat mass, lean body mass, bone mineral content and density, and total body weight....

  2. Precision top-quark mass measurement at CDF.

    Science.gov (United States)

    Aaltonen, T; Alvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Bisello, D; Bizjak, I; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Calamba, A; Calancha, C; Camarda, S; Campanelli, M; Campbell, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chung, W H; Chung, Y S; Ciocci, M A; Clark, A; Clarke, C; Compostella, G; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Crescioli, F; Cuevas, J; Culbertson, R; Dagenhart, D; d'Ascenzo, N; Datta, M; de Barbaro, P; Dell'Orso, M; Demortier, L; Deninno, M; Devoto, F; d'Errico, M; Di Canto, A; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Dorigo, M; Dorigo, T; Ebina, K; Elagin, A; Eppig, A; Erbacher, R; Errede, S; Ershaidat, N; Eusebi, R; Farrington, S; Feindt, M; Fernandez, J P; Field, R; Flanagan, G; Forrest, R; Frank, M J; Franklin, M; Freeman, J C; Funakoshi, Y; Furic, I; Gallinaro, M; Garcia, J E; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Halkiadakis, E; Hamaguchi, A; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harr, R F; Hatakeyama, K; Hays, C; Heck, M; Heinrich, J; Herndon, M; Hewamanage, S; Hocker, A; Hopkins, W; Horn, D; Hou, S; Hughes, R E; Hurwitz, M; Husemann, U; Hussain, N; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kim, Y J; Kimura, N; Kirby, M; Klimenko, S; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Kruse, M; Krutelyov, V; Kuhr, T; Kurata, M; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; LeCompte, T; Lee, E; Lee, H S; Lee, J S; Lee, S W; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lin, C-J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, C; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maeshima, K; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Martínez, M; Mastrandrea, P; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Mondragon, M N; Moon, C S; Moore, R; Morello, M J; Morlock, J; Movilla Fernandez, P; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Neubauer, M S; Nielsen, J; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagan Griso, S; Pagliarone, C; Palencia, E; Papadimitriou, V; Paramonov, A A; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Prokoshin, F; Pranko, A; Ptohos, F; Punzi, G; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Renton, P; Rescigno, M; Riddick, T; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Safonov, A; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sinervo, P; Sliwa, K; Smith, J R; Snider, F D; Soha, A; Sorin, V; Song, H; Squillacioti, P; Stancari, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thome, J; Thompson, G A; Thomson, E; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Varganov, A; Vázquez, F; Velev, G; Vellidis, C; Vidal, M; Vila, I; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wagner, R L; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wicklund, E; Wilbur, S; Wick, F; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanetti, A; Zeng, Y; Zhou, C; Zucchelli, S

    2012-10-12

    We present a precision measurement of the top-quark mass using the full sample of Tevatron √s = 1.96 TeV proton-antiproton collisions collected by the CDF II detector, corresponding to an integrated luminosity of 8.7 fb(-1). Using a sample of tt¯ candidate events decaying into the lepton+jets channel, we obtain distributions of the top-quark masses and the invariant mass of two jets from the W boson decays from data. We then compare these distributions to templates derived from signal and background samples to extract the top-quark mass and the energy scale of the calorimeter jets with in situ calibration. The likelihood fit of the templates from signal and background events to the data yields the single most-precise measurement of the top-quark mass, M(top)=172.85±0.71(stat)±0.85(syst) GeV/c(2).

  3. Direct mass measurements of neutron-deficient xenon isotopes with the ISOLTRAP mass spectrometer

    International Nuclear Information System (INIS)

    Dilling, J.; Audi, G.; Beck, D.; Bollen, G.; Henry, S.; Herfurth, F.; Kellerbauer, A.; Kluge, H.-J.; Lunney, D.; Moore, R.B.; Scheidenberger, C.; Schwarz, S.; Sikler, G.; Szerypo, J.

    2002-01-01

    The masses of Xe isotopes with 124≥A≥114 have been measured using the ISOLTRAP spectrometer at the on-line mass separator ISOLDE/CERN. A mass resolving power of 500 000 was chosen resulting in an accuracy of δm∼12 keV for all isotopes investigated. Conflicts with existing mass data of several standard deviations were found

  4. Reliability of biceps femoris and semitendinosus muscle architecture measurements obtained with ultrasonography

    Directory of Open Access Journals (Sweden)

    Viviane Bastos de Oliveira

    Full Text Available Introduction Currently, little attention is given to the muscle architecture reliability studies of the hamstring using a robust statistical. Our purpose was to determine the reliability of ultrasound measurements of muscle thickness, fascicle length and pennation angle of the biceps femoris and semitendinosus muscles, including heteroskedasticity and internal consistency analyses. Methods Two images of biceps femoris and semitendinosus at 50% of the thigh length were acquired from 21 volunteers, in two visits. The parameters were measured three times in each image, and for each muscle. The reliability was analyzed by the intraclass correlation coefficient (ICC and Cronbach’s alpha (αCronbach. The relative standard error of the measurements (%SEM were calculated and Bland-Altman plots were generated. Results All parameters presented excellent ICC for the three repeated measurements (ICC from 0.93 ‒ 0.99 and moderate to excellent reliability intraday (ICC from 0.70 ‒ 0.95 for both muscles. The present study indicates that ultrasound is a reliable tool to estimate the biceps femoris fascicle length (ICC = 0.97, αCronbach = 0.98, %SEM = 7.86 and semitendinosus (ICC = 0.90, αCronbach = 0.95, %SEM = 7.55, as well as the biceps femoris muscle thickness (ICC = 0.89, αCronbach = 0.94, %SEM = 10.23 and semitendinosus muscle thickness (ICC = 0.87, αCronbach = 0.93, %SEM = 1.35. At last, biceps femoris pennation angle (ICC = 0.93, αCronbach = 0.96 and %SEM = 4.36 and semitendinosus (ICC = 0.96, αCronbach = 0.98 and %SEM = 4.25 also had good repeatability. Conclusion Ultrasonography show good repeatability in estimating of muscle architecture parameters.

  5. The effect of non-sphericity on mass and anisotropy measurements in dSph galaxies with Schwarzschild method

    Science.gov (United States)

    Kowalczyk, Klaudia; Łokas, Ewa L.; Valluri, Monica

    2018-05-01

    In our previous work we confirmed the reliability of the spherically symmetric Schwarzschild orbit-superposition method to recover the mass and velocity anisotropy profiles of spherical dwarf galaxies. Here, we investigate the effect of its application to intrinsically non-spherical objects. For this purpose we use a model of a dwarf spheroidal galaxy formed in a numerical simulation of a major merger of two discy dwarfs. The shape of the stellar component of the merger remnant is axisymmetric and prolate which allows us to identify and measure the bias caused by observing the spheroidal galaxy along different directions, especially the longest and shortest principal axis. The modelling is based on mock data generated from the remnant that are observationally available for dwarfs: projected positions and line-of-sight velocities of the stars. In order to obtain a reliable tool while keeping the number of parameters low we parametrize the total mass distribution as a radius-dependent mass-to-light ratio with just two free parameters we aim to constrain. Our study shows that if the total density profile is known, the true, radially increasing anisotropy profile can be well recovered for the observations along the longest axis whereas the data along the shortest axis lead to the inference of an incorrect, isotropic model. On the other hand, if the density profile is derived from the method as well, the anisotropy is always underestimated but the total mass profile is well recovered for the data along the shortest axis whereas for the longest axis the mass content is overestimated.

  6. Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer.

    Science.gov (United States)

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-01-01

    To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.

  7. Reliability of smartphone-based gait measurements for quantification of physical activity/inactivity levels.

    Science.gov (United States)

    Ebara, Takeshi; Azuma, Ryohei; Shoji, Naoto; Matsukawa, Tsuyoshi; Yamada, Yasuyuki; Akiyama, Tomohiro; Kurihara, Takahiro; Yamada, Shota

    2017-11-25

    Objective measurements using built-in smartphone sensors that can measure physical activity/inactivity in daily working life have the potential to provide a new approach to assessing workers' health effects. The aim of this study was to elucidate the characteristics and reliability of built-in step counting sensors on smartphones for development of an easy-to-use objective measurement tool that can be applied in ergonomics or epidemiological research. To evaluate the reliability of step counting sensors embedded in seven major smartphone models, the 6-minute walk test was conducted and the following analyses of sensor precision and accuracy were performed: 1) relationship between actual step count and step count detected by sensors, 2) reliability between smartphones of the same model, and 3) false detection rates when sitting during office work, while riding the subway, and driving. On five of the seven models, the inter-class correlations coefficient (ICC (3,1) ) showed high reliability with a range of 0.956-0.993. The other two models, however, had ranges of 0.443-0.504 and the relative error ratios of the sensor-detected step count to the actual step count were ±48.7%-49.4%. The level of agreement between the same models was ICC (3,1) : 0.992-0.998. The false detection rates differed between the sitting conditions. These results suggest the need for appropriate regulation of step counts measured by sensors, through means such as correction or calibration with a predictive model formula, in order to obtain the highly reliable measurement results that are sought in scientific investigation.

  8. Inter-rater and intra-rater reliability of a clinical protocol for measuring turnout in collegiate dancers.

    Science.gov (United States)

    Greene, Amanda; Lasner, Andrea; Deu, Rajwinder; Oliphant, Seth; Johnson, Kenneth

    2018-02-02

    Reliable methods of measuring turnout in dancers and comparing active turnout (used in class) with functional (uncompensated) turnout are needed. Authors have suggested measurement techniques but there is no clinically useful, easily reproducible technique with established inter-rater and intra-rater reliability. We adapted a technique based on previous research, which is easily reproducible. We hypothesized excellent inter-rater and intra-rater reliability between experienced physical therapists (PTs) and a briefly trained faculty member from a university's department of dance. Thirty-two participants were recruited from the same dance department. Dancers' active and functional turnout was measured by each rater. We found that our technique for measuring active and functional turnout has excellent inter-rater and intra-rater reliability when performed by two experienced PTs and by one briefly trained university-level dance faculty member. For active turnout, inter-rater reliability was 0.78 among all raters and 0.82 among only the PT raters; intra-rater reliability was 0.82 among all raters and 0.85 among only the PT raters. For functional turnout, inter-rater reliability was 0.86 among all raters and 0.88 among only the PT raters; intra-rater reliability was 0.87 among all raters and 0.88 among only the PT raters. The measurement technique described provides a standardized protocol with excellent inter-rater and intra-rater reliability when performed by experienced PTs or by a briefly trained university-level dance faculty member.

  9. First direct mass measurements on nobelium and lawrencium with the Penning trap mass spectrometer SHIPTRAP

    Energy Technology Data Exchange (ETDEWEB)

    Dworschak, Michael Gerhard

    2009-12-08

    The Penning trap mass spectrometer SHIPTRAP at GSI Darmstadt was set up for high-precision mass measurements of heavy radionuclides produced in fusion evaporation reactions and separated from the primary beam by the velocity filter SHIP. It consists of a gas stopping cell for the deceleration of the high energetic reaction products, an RFQ cooler and buncher for cooling and accumulation of the ions, and a double Penning trap system to perform mass measurements. The mass is determined by measuring the cyclotron frequency of the ion of interest in a strong homogeneous magnetic field and comparing it to the frequency of a well-known reference ion. With this method relative uncertainties in the order of 10{sup -8} can be achieved. Recently, mass measurements of the three nobelium isotopes {sup 252-254}No (Z=102) and the lawrencium isotope {sup 255}Lr (Z=103) were performed successfully. These were the first direct mass measurements of transuranium elements ever per- formed. The production rate of the atoms of interest was about one per second or less. The results of the measurements on nobelium confirm the previous mass values which were deduced from Q{sub {alpha}} values. In the case of {sup 255}Lr the mass excess value, which was previously only estimated from systematic trends, was for the first time directly measured. These results mark the first step in the exploration of the region of transuranium elements which is planned at SHIPTRAP. The main objective is to fix the endpoints of {alpha} decay chains which are originating from superheavy elements close to the predicted island of stability. (orig.)

  10. Reliability of Phase Velocity Measurements of Flexural Acoustic Waves in the Human Tibia In-Vivo.

    Science.gov (United States)

    Vogl, Florian; Schnüriger, Karin; Gerber, Hans; Taylor, William R

    2016-01-01

    Axial-transmission acoustics have shown to be a promising technique to measure individual bone properties and detect bone pathologies. With the ultimate goal being the in-vivo application of such systems, quantification of the key aspects governing the reliability is crucial to bring this method towards clinical use. This work presents a systematic reliability study quantifying the sources of variability and their magnitudes of in-vivo measurements using axial-transmission acoustics. 42 healthy subjects were measured by an experienced operator twice per week, over a four-month period, resulting in over 150000 wave measurements. In a complementary study to assess the influence of different operators performing the measurements, 10 novice operators were trained, and each measured 5 subjects on a single occasion, using the same measurement protocol as in the first part of the study. The estimated standard error for the measurement protocol used to collect the study data was ∼ 17 m/s (∼ 4% of the grand mean) and the index of dependability, as a measure of reliability, was Φ = 0.81. It was shown that the method is suitable for multi-operator use and that the reliability can be improved efficiently by additional measurements with device repositioning, while additional measurements without repositioning cannot improve the reliability substantially. Phase velocity values were found to be significantly higher in males than in females (p < 10-5) and an intra-class correlation coefficient of r = 0.70 was found between the legs of each subject. The high reliability of this non-invasive approach and its intrinsic sensitivity to mechanical properties opens perspectives for the rapid and inexpensive clinical assessment of bone pathologies, as well as for monitoring programmes without any radiation exposure for the patient.

  11. Measuring the Higgs mass at TESLA

    International Nuclear Information System (INIS)

    Garcia-Abia, P.; Lohmann, W.; Raspereza, A.

    2001-01-01

    We report on the accuracy of the measurement of the Higgs boson mass that would be achieved in a linear collider operating at a center-of-mass energy of 350 GeV, assuming an integrated luminosity of 500 fb-1. For that we have exploited the exclusive Higgs decays into b quarks and W bosons. The Higgs mass is determined with an accuracy of about 40 MeV for m H =120 GeV and 80 MeV for m H =180 GeV

  12. Spent fuel critical masses and supportive measurements

    International Nuclear Information System (INIS)

    Toffer, H.; Wells, A.H.

    1987-01-01

    Critical masses for spent fuel are larger than for green fuel and therefore use of the increased masses could result in improved handling, storage, and transport of such materials. To apply spent fuel critical masses requires an assessment of fuel exposure and the corresponding isotopic compositions. The paper discusses several approaches at the Hanford N Reactor in establishing fuel exposure, including a direct measurement of spent to green fuel critical masses. The benefits derived from the use of spent fuel critical masses are illustrated for cask designs at the Nuclear Assurance Corporation. (author)

  13. Measurements of the top quark mass with the ATLAS detector

    CERN Document Server

    Brandt, Oleg; The ATLAS collaboration

    2018-01-01

    The top quark mass is one of the fundamental parameters of the Standard Model. The latest ATLAS measurements of the top quark mass are presented. A measurement using lepton+jets events is presented, where a multidimensional template fit is used to constrain the uncertainties on the energy measurements of jets. The measurement is combined with a measurement using dilepton events. In addition, novel measurements aiming to measure the mass in a welldefined scheme are presented. These measurements use precision theoretical QCD calculations for both inclusive ttbar production and ttbar production with an additional jet to extract the top quark mass in the polemass scheme.

  14. Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength.

    Science.gov (United States)

    Douma, K W; Regterschot, G R H; Krijnen, W P; Slager, G E C; van der Schans, C P; Zijlstra, W

    2016-01-01

    The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various degrees of extension. Measurements between 110 and 130° extension present the highest values and the most significant increase after training. The objective of this study is to determine the test-retest reliability of muscle strength measurements by the Q Force in older adults in 110° extension. Forty-one healthy older adults, 13 males and 28 females were included in the study. Mean (SD) age was 81.9 (4.89) years. Isometric muscle strength of the Quadriceps muscle was assessed with the Q Force at 110° of knee extension. Participants were measured at two sessions with a three to eight day interval between sessions. To determine relative reliability, the intraclass correlation coefficient (ICC) was calculated. To determine absolute reliability, Bland and Altman Limits of Agreement (LOA) were calculated and t-tests were performed. Relative reliability of the Q Force is good to excellent as all ICC coefficients are higher than 0.75. Generally a large 95 % LOA, reflecting only moderate absolute reliability, is found as exemplified for the peak torque left leg of -18.6 N to 33.8 N and the right leg of -9.2 N to 26.4 N was between 15.7 and 23.6 Newton representing 25.2 % to 39.9 % of the size of the mean. Small systematic differences in mean were found between measurement session 1 and 2. The present study shows that the Q Force has excellent relative test-retest reliability, but limited absolute test-retest reliability. Since the Q Force is relatively cheap and mobile it is suitable for

  15. Interrater Reliability of mHealth App Rating Measures: Analysis of Top Depression and Smoking Cessation Apps.

    Science.gov (United States)

    Powell, Adam C; Torous, John; Chan, Steven; Raynor, Geoffrey Stephen; Shwarts, Erik; Shanahan, Meghan; Landman, Adam B

    2016-02-10

    There are over 165,000 mHealth apps currently available to patients, but few have undergone an external quality review. Furthermore, no standardized review method exists, and little has been done to examine the consistency of the evaluation systems themselves. We sought to determine which measures for evaluating the quality of mHealth apps have the greatest interrater reliability. We identified 22 measures for evaluating the quality of apps from the literature. A panel of 6 reviewers reviewed the top 10 depression apps and 10 smoking cessation apps from the Apple iTunes App Store on these measures. Krippendorff's alpha was calculated for each of the measures and reported by app category and in aggregate. The measure for interactiveness and feedback was found to have the greatest overall interrater reliability (alpha=.69). Presence of password protection (alpha=.65), whether the app was uploaded by a health care agency (alpha=.63), the number of consumer ratings (alpha=.59), and several other measures had moderate interrater reliability (alphas>.5). There was the least agreement over whether apps had errors or performance issues (alpha=.15), stated advertising policies (alpha=.16), and were easy to use (alpha=.18). There were substantial differences in the interrater reliabilities of a number of measures when they were applied to depression versus smoking apps. We found wide variation in the interrater reliability of measures used to evaluate apps, and some measures are more robust across categories of apps than others. The measures with the highest degree of interrater reliability tended to be those that involved the least rater discretion. Clinical quality measures such as effectiveness, ease of use, and performance had relatively poor interrater reliability. Subsequent research is needed to determine consistent means for evaluating the performance of apps. Patients and clinicians should consider conducting their own assessments of apps, in conjunction with

  16. Top-quark mass measurements: Alternative techniques (LHC + Tevatron)

    CERN Document Server

    Adomeit, Stefanie; The ATLAS collaboration

    2014-01-01

    Measurements of the top-quark mass employing alternative techniques are presented, performed by the D0 and CDF collaborations at the Tevatron as well as the ATLAS and CMS experiments at the LHC. The alternative methods presented include measurements using the lifetime of $B$-hadrons, the transverse momentum of charged leptons and the endpoints of kinematic distributions in top quark anti-quark pair ($t\\bar{t}$) final states. The extraction of the top-quark pole mass from the $t\\bar{t}$ production cross-section and the normalized differential $t\\bar{t}$ + 1-jet cross-section are discussed as well as the top-quark mass extraction using fixed-order QCD predictions at detector level. Finally, a measurement of the top-quark mass using events enhanced in single top t-channel production is presented.

  17. Reliability and accuracy analysis of a new semiautomatic radiographic measurement software in adult scoliosis.

    Science.gov (United States)

    Aubin, Carl-Eric; Bellefleur, Christian; Joncas, Julie; de Lanauze, Dominic; Kadoury, Samuel; Blanke, Kathy; Parent, Stefan; Labelle, Hubert

    2011-05-20

    Radiographic software measurement analysis in adult scoliosis. To assess the accuracy as well as the intra- and interobserver reliability of measuring different indices on preoperative adult scoliosis radiographs using a novel measurement software that includes a calibration procedure and semiautomatic features to facilitate the measurement process. Scoliosis requires a careful radiographic evaluation to assess the deformity. Manual and computer radiographic process measures have been studied extensively to determine the reliability and reproducibility in adolescent idiopathic scoliosis. Most studies rely on comparing given measurements, which are repeated by the same user or by an expert user. A given measure with a small intra- or interobserver error might be deemed as good repeatability, but all measurements might not be truly accurate because the ground-truth value is often unknown. Thorough accuracy assessment of radiographic measures is necessary to assess scoliotic deformities, compare these measures at different stages or to permit valid multicenter studies. Thirty-four sets of adult scoliosis digital radiographs were measured two times by three independent observers using a novel radiographic measurement software that includes semiautomatic features to facilitate the measurement process. Twenty different measures taken from the Spinal Deformity Study Group radiographic measurement manual were performed on the coronal and sagittal images. Intra- and intermeasurer reliability for each measure was assessed. The accuracy of the measurement software was also assessed using a physical spine model in six different scoliotic configurations as a true reference. The majority of the measures demonstrated good to excellent intra- and intermeasurer reliability, except for sacral obliquity. The standard variation of all the measures was very small: ≤ 4.2° for Cobb angles, ≤ 4.2° for the kyphosis, ≤ 5.7° for the lordosis, ≤ 3.9° for the pelvic angles, and

  18. A Reliable Method to Measure Lip Height Using Photogrammetry in Unilateral Cleft Lip Patients.

    Science.gov (United States)

    van der Zeeuw, Frederique; Murabit, Amera; Volcano, Johnny; Torensma, Bart; Patel, Brijesh; Hay, Norman; Thorburn, Guy; Morris, Paul; Sommerlad, Brian; Gnarra, Maria; van der Horst, Chantal; Kangesu, Loshan

    2015-09-01

    There is still no reliable tool to determine the outcome of the repaired unilateral cleft lip (UCL). The aim of this study was therefore to develop an accurate, reliable tool to measure vertical lip height from photographs. The authors measured the vertical height of the cutaneous and vermilion parts of the lip in 72 anterior-posterior view photographs of 17 patients with repairs to a UCL. Points on the lip's white roll and vermillion were marked on both the cleft and the noncleft sides on each image. Two new concepts were tested. First, photographs were standardized using the horizontal (medial to lateral) eye fissure width (EFW) for calibration. Second, the authors tested the interpupillary line (IPL) and the alar base line (ABL) for their reliability as horizontal lines of reference. Measurements were taken by 2 independent researchers, at 2 different time points each. Overall 2304 data points were obtained and analyzed. Results showed that the method was very effective in measuring the height of the lip on the cleft side with the noncleft side. When using the IPL, inter- and intra-rater reliability was 0.99 to 1.0, with the ABL it varied from 0.91 to 0.99 with one exception at 0.84. The IPL was easier to define because in some subjects the overhanging nasal tip obscured the alar base and gave more consistent measurements possibly because the reconstructed alar base was sometimes indistinct. However, measurements from the IPL can only give the percentage difference between the left and right sides of the lip, whereas those from the ABL can also give exact measurements. Patient examples were given that show how the measurements correlate with clinical assessment. The authors propose this method of photogrammetry with the innovative use of the IPL as a reliable horizontal plane and use of the EFW for calibration as a useful and reliable tool to assess the outcome of UCL repair.

  19. Reliability measures in managing GI bleeding.

    Science.gov (United States)

    Sonnenberg, Amnon

    2012-06-01

    Multiple procedures and devices are used in a complex interplay to diagnose and treat GI bleeding. To model how a large variety of diagnostic and therapeutic components interact in the successful management of GI bleeding. The analysis uses the concept of reliability block diagrams from probability theory to model management outcome. Separate components of the management process are arranged in a serial or parallel fashion. If the outcome depends on the function of each component individually, such components are modeled to be arranged in series. If components complement each other and can mutually compensate for each of their failures, such components are arranged in a parallel fashion. General endoscopy practice. Patients with GI bleeding of unknown etiology. All available endoscopic and radiographic means to diagnose and treat GI bleeding. Process reliability in achieving hemostasis. Serial arrangements tend to reduce process reliability, whereas parallel arrangements increase it. Whenever possible, serial components should be bridged and complemented by additional alternative (parallel) routes of operation. Parallel components with low individual reliability can still contribute to overall process reliability as long as they function independently of other pre-existing alternatives. Probability of success associated with individual components is partly unknown. Modeling management of GI bleeding by a reliability block diagram provides a useful tool in assessing the impact of individual endoscopic techniques and administrative structures on the overall outcome. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  20. Radiochemical measurement of mass transport in sodium

    International Nuclear Information System (INIS)

    Cooper, M.H.; Chiang, S.H.

    1976-01-01

    Mass transport processes in the sodium coolant of Liquid Metal Fast Breeder Reactors (LMFBRs) are significant in determining rates of corrosion and deposition of radioactive nuclides from the fuel cladding, deposition and cold trapping of fission products from defect or failed fuel, carbon and nitrogen redistribution in the containment materials, and removal of impurities by cold trapping or hot trapping. Mass transport between rotating, concentric cylinders in molten sodium has been investigated using a unique radiochemical method. Long-lived (33 year) cesium-137, dissolved in the sodium, decays radioactively emitting a beta to barium-137m, which decays with a short half-life (2.6 minutes) emitting a gamma. Cesium is weakly adsorbed and remains in solution, while the barium is strongly adsorbed on the stainless steel surfaces. Hence, by measuring the barium-137m activity on movable stainless steel surfaces, one can calculate the mass transport to that surface. Mass transfer coefficients in sodium measured by this method are in agreement with published heat transfer correlations when the effect of the volumetric mass source is taken into account. Hence, heat transfer correlations can be confidently utilized by analogy in estimating mass transfer in liquid-metal systems

  1. Feasibility and Inter-Rater Reliability of Physical Performance Measures in Acutely Admitted Older Medical Patients

    DEFF Research Database (Denmark)

    Bodilsen, Ann Christine; Juul-Larsen, Helle Gybel; Petersen, Janne

    2015-01-01

    OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter-rater reliabi......OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter......-rater reliability of four simple measures of physical performance in acutely admitted older medical patients. DESIGN: During the first 24 hours of hospitalization, the following were assessed twice by different raters in 52 (≥ 65 years) patients admitted for acute medical illness: isometric hand grip strength, 4......, and 30-s chair stand were 8%, 7%, and 18%, and the SRD95% values were 22%, 17%, and 49%. CONCLUSION: In acutely admitted older medical patients, grip strength, gait speed, and the Cumulated Ambulation Score measurements were feasible and showed high inter-rater reliability when administered by different...

  2. Measuring Convective Mass Fluxes Over Tropical Oceans

    Science.gov (United States)

    Raymond, David

    2017-04-01

    Deep convection forms the upward branches of all large-scale circulations in the tropics. Understanding what controls the form and intensity of vertical convective mass fluxes is thus key to understanding tropical weather and climate. These mass fluxes and the corresponding conditions supporting them have been measured by recent field programs (TPARC/TCS08, PREDICT, HS3) in tropical disturbances considered to be possible tropical storm precursors. In reality, this encompasses most strong convection in the tropics. The measurements were made with arrays of dropsondes deployed from high altitude. In some cases Doppler radar provided additional measurements. The results are in some ways surprising. Three factors were found to control the mass flux profiles, the strength of total surface heat fluxes, the column-integrated relative humidity, and the low to mid-tropospheric moist convective instability. The first two act as expected, with larger heat fluxes and higher humidity producing more precipitation and stronger lower tropospheric mass fluxes. However, unexpectedly, smaller (but still positive) convective instability produces more precipitation as well as more bottom-heavy convective mass flux profiles. Furthermore, the column humidity and the convective instability are anti-correlated, at least in the presence of strong convection. On spatial scales of a few hundred kilometers, the virtual temperature structure appears to be in dynamic balance with the pattern of potential vorticity. Since potential vorticity typically evolves on longer time scales than convection, the potential vorticity pattern plus the surface heat fluxes then become the immediate controlling factors for average convective properties. All measurements so far have taken place in regions with relatively flat sea surface temperature (SST) distributions. We are currently seeking funding for a measurement program in the tropical east Pacific, a region that exhibits strong SST gradients and

  3. Toward a Common Language for Measuring Patient Mobility in the Hospital: Reliability and Construct Validity of Interprofessional Mobility Measures.

    Science.gov (United States)

    Hoyer, Erik H; Young, Daniel L; Klein, Lisa M; Kreif, Julie; Shumock, Kara; Hiser, Stephanie; Friedman, Michael; Lavezza, Annette; Jette, Alan; Chan, Kitty S; Needham, Dale M

    2018-02-01

    The lack of common language among interprofessional inpatient clinical teams is an important barrier to achieving inpatient mobilization. In The Johns Hopkins Hospital, the Activity Measure for Post-Acute Care (AM-PAC) Inpatient Mobility Short Form (IMSF), also called "6-Clicks," and the Johns Hopkins Highest Level of Mobility (JH-HLM) are part of routine clinical practice. The measurement characteristics of these tools when used by both nurses and physical therapists for interprofessional communication or assessment are unknown. The purposes of this study were to evaluate the reliability and minimal detectable change of AM-PAC IMSF and JH-HLM when completed by nurses and physical therapists and to evaluate the construct validity of both measures when used by nurses. A prospective evaluation of a convenience sample was used. The test-retest reliability and the interrater reliability of AM-PAC IMSF and JH-HLM for inpatients in the neuroscience department (n = 118) of an academic medical center were evaluated. Each participant was independently scored twice by a team of 2 nurses and 1 physical therapist; a total of 4 physical therapists and 8 nurses participated in reliability testing. In a separate inpatient study protocol (n = 69), construct validity was evaluated via an assessment of convergent validity with other measures of function (grip strength, Katz Activities of Daily Living Scale, 2-minute walk test, 5-times sit-to-stand test) used by 5 nurses. The test-retest reliability values (intraclass correlation coefficients) for physical therapists and nurses were 0.91 and 0.97, respectively, for AM-PAC IMSF and 0.94 and 0.95, respectively, for JH-HLM. The interrater reliability values (intraclass correlation coefficients) between physical therapists and nurses were 0.96 for AM-PAC IMSF and 0.99 for JH-HLM. Construct validity (Spearman correlations) ranged from 0.25 between JH-HLM and right-hand grip strength to 0.80 between AM-PAC IMSF and the Katz Activities of

  4. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 2. Technical Report #1201

    Science.gov (United States)

    Lai, Cheng-Fei; Irvin, P. Shawn; Alonzo, Julie; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the second-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  5. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 3. Technical Report #1202

    Science.gov (United States)

    Lai, Cheng-Fei; Irvin, P. Shawn; Park, Bitnara Jasmine; Alonzo, Julie; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the third-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  6. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 5. Technical Report #1204

    Science.gov (United States)

    Park, Bitnara Jasmine; Irvin, P. Shawn; Lai, Cheng-Fei; Alonzo, Julie; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the fifth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  7. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 4. Technical Report #1203

    Science.gov (United States)

    Park, Bitnara Jasmine; Irvin, P. Shawn; Alonzo, Julie; Lai, Cheng-Fei; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the fourth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  8. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 6. Technical Report #1205

    Science.gov (United States)

    Irvin, P. Shawn; Alonzo, Julie; Park, Bitnara Jasmine; Lai, Cheng-Fei; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the sixth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  9. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 7. Technical Report #1206

    Science.gov (United States)

    Irvin, P. Shawn; Alonzo, Julie; Lai, Cheng-Fei; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the seventh-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  10. Night-to-night arousal variability and interscorer reliability of arousal measurements.

    Science.gov (United States)

    Loredo, J S; Clausen, J L; Ancoli-Israel, S; Dimsdale, J E

    1999-11-01

    Measurement of arousals from sleep is clinically important, however, their definition is not well standardized, and little data exist on reliability. The purpose of this study is to determine factors that affect arousal scoring reliability and night-to-night arousal variability. The night-to-night arousal variability and interscorer reliability was assessed in 20 subjects with and without obstructive sleep apnea undergoing attended polysomnography during two consecutive nights. Five definitions of arousal were studied, assessing duration of electroencephalographic (EEG) frequency changes, increases in electromyographic (EMG) activity and leg movement, association with respiratory events, as well as the American Sleep Disorders Association (ASDA) definition of arousals. NA. NA. NA. Interscorer reliability varied with the definition of arousal and ranged from an Intraclass correlation (ICC) of 0.19 to 0.92. Arousals that included increases in EMG activity or leg movement had the greatest reliability, especially when associated with respiratory events (ICC 0.76 to 0.92). The ASDA arousal definition had high interscorer reliability (ICC 0.84). Reliability was lowest for arousals consisting of EEG changes lasting <3 seconds (ICC 0.19 to 0.37). The within subjects night-to-night arousal variability was low for all arousal definitions In a heterogeneous population, interscorer arousal reliability is enhanced by increases in EMG activity, leg movements, and respiratory events and decreased by short duration EEG arousals. The arousal index night-to-night variability was low for all definitions.

  11. Reliability of rehabilitative ultrasonographic imaging for muscle thickness measurement of the rhomboid major.

    Science.gov (United States)

    Jeong, Ju Ri; Ko, Young Jun; Ha, Hyun Geun; Lee, Wan Hee

    2016-03-01

    This study was to establish inter-rater and intrarater reliability of the rehabilitative ultrasonographic imaging (RUSI) technique for muscle thickness measurement of the rhomboid major at rest and with the shoulder abducted to 90°. Twenty-four young adults (eight men, 16 women; right-handed; mean age [±SD], 24·4 years [±2·6]) with no history of neck, shoulder, or arm pain were recruited. Rhomboid major muscle images were obtained in the resting position and with shoulder in 90° abduction using an ultrasonography system with a 7·5-MHz linear transducer. In these two positions, the examiners found the site at which the transducer could be placed. Two examiners obtained the images of all participants in three test sessions at random. Intraclass correlation coefficients (ICC) were used to estimate reliability. All ICCs (95% CI) were >0·75, ranging from 0·93 to 0·98, which indicates good reliability. The ICCs for inter-rater reliability ranged from 0·75 to 0·94. For the absolute value of the difference in the intra-examiner reliability between the right and left ratios, the ICCs ranged from 0·58 to 0·91. In this study, the intra- and interexaminer reliability of muscle thickness measurements of the rhomboid major were good. Therefore, we suggest that muscle thickness measurements of the rhomboid major obtained with the RUSI technique would be useful for clinical rehabilitative assessment. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  12. Low-Budget Instrumentation of a Conventional Leg Press to Measure Reliable Isometric-Strength Capacity.

    Science.gov (United States)

    Baur, Heiner; Groppa, Alessia Severina; Limacher, Regula; Radlinger, Lorenz

    2016-02-02

    Maximum strength and rate of force development (RFD) are 2 important strength characteristics for everyday tasks and athletic performance. Measurements of both parameters must be reliable. Expensive isokinetic devices with isometric modes are often used. The possibility of cost-effective measurements in a practical setting would facilitate quality control. The purpose of this study was to assess the reliability of measurements of maximum isometric strength (Fmax) and RFD on a conventional leg press. Sixteen subjects (23 ± 2 y, 1.68 ± 0.05 m, 59 ± 5 kg) were tested twice within 1 session. After warm-up, subjects performed 2 times 5 trials eliciting maximum voluntary isometric contractions on an instrumented leg press (1- and 2-legged randomized). Fmax (N) and RFD (N/s) were extracted from force-time curves. Reliability was determined for Fmax and RFD by calculating the intraclass correlation coefficient (ICC), the test-retest variability (TRV), and the bias and limits of agreement. Reliability measures revealed good to excellent ICCs of .80-.93. TRV showed mean differences between measurement sessions of 0.4-6.9%. The systematic error was low compared with the absolute mean values (Fmax 5-6%, RFD 1-4%). The implementation of a force transducer into a conventional leg press provides a viable procedure to assess Fmax and RFD. Both performance parameters can be assessed with good to excellent reliability allowing quality control of interventions.

  13. Mass thickness measurement of dual-sample by dual-energy X-rays

    International Nuclear Information System (INIS)

    Chen Mincong; Li Hongmei; Chen Ziyu; Shen Ji

    2008-01-01

    X-ray equivalent energy can be used to measure mass thicknesses of materials. Based on this, a method of mass thickness measurement of dual-sample was discussed. It was found that in the range of sample mass thickness under investigation, the equivalent mass attenuation coefficient of a component could be used to compute mass thicknesses of a dual-sample, with relative errors of less than 5%. Mass thickness measurement of a fish sample was performed, and the fish bone and flesh could be displayed separately and clearly by their own mass thicknesses. This indicates that the method is effective in mass thickness measurement of dual-sample of suitable thicknesses. (authors)

  14. Precision mass measurements at THe-trap and the FSU trap

    Energy Technology Data Exchange (ETDEWEB)

    Hoecker, Martin Juergen

    2016-07-26

    THe-Trap is a Penning-trap mass spectrometer at the Max-Planck-Institute for Nuclear Physics in Heidelberg, Germany, that aims to measure the T/{sup 3}He mass ratio with a relative uncertainty of 10{sup -11}. Improvements of the measurement technique, in particular the measurement of systematic shifts, enabled measurements of mass ratios with relative uncertainties of 7.10{sup -11}, as demonstrated by a cyclotron frequency ratio determination on {sup 12}C{sup 4+}/{sup 16}O{sup 5+}. This uncertainty was limited by the lineshape. An improved theoretical model based on a rotating wave approximation can be used to describe dynamical interactions between the detection system and the ion, in order to better understand the lineshape and to further reduce the uncertainty. The Florida State University trap is a Penning-trap mass spectrometer located in Tallahassee, Florida (USA). In the context of this thesis, three mass ratios were measured, and further 20 mass ratio measurements analyzed, which resulted in the publication of the masses of {sup 82,83}Kr, {sup 131,134}Xe, {sup 86-88}Sr, and {sup 170-174,176}Yb with relative uncertainties between (0.9 - 1.3).10{sup -10}. These masses serve as reference masses for other experiments and have applications in the determination of the fine-structure constant alpha via the photon-recoil method.

  15. The reliability of repeated TMS measures in older adults and in patients with subacute and chronic stroke

    Directory of Open Access Journals (Sweden)

    Heidi M. Schambra

    2015-09-01

    Full Text Available The reliability of transcranial magnetic stimulation (TMS measures in healthy older adults and stroke patients has been insufficiently characterized. We determined whether common TMS measures could reliably evaluate change in individuals and in groups using the smallest detectable change (SDC, or could tell subjects apart using the intraclass correlation coefficient (ICC. We used a single-rater test-retest design in older healthy, subacute stroke, and chronic stroke subjects. At twice daily sessions on two consecutive days, we recorded resting motor threshold, test stimulus intensity, recruitment curves, short-interval intracortical inhibition and facilitation, and long-interval intracortical inhibition. Using variances estimated from a random effects model, we calculated the SDC and ICC for each TMS measure. For all TMS measures in all groups, SDCs for single subjects were large; only with modest group sizes did the SDCs become low. Thus, while these TMS measures cannot be reliably used as a biomarker to detect individual change, they can reliably detect change exceeding measurement noise in moderate-sized groups. For several of the TMS measures, ICCs were universally high, suggesting that they can reliably discriminate between subjects. Though most TMS measures have sufficient reliability in particular contexts, work establishing their validity, responsiveness, and clinical relevance is still needed.

  16. Propellant Slosh Force and Mass Measurement

    Directory of Open Access Journals (Sweden)

    Andrew Hunt

    2018-01-01

    Full Text Available We have used electrical capacitance tomography (ECT to instrument a demonstration tank containing kerosene and have successfully demonstrated that ECT can, in real time, (i measure propellant mass to better than 1% of total in a range of gravity fields, (ii image propellant distribution, and (iii accurately track propellant centre of mass (CoM. We have shown that the ability to track CoM enables the determination of slosh forces, and we argue that this will result in disruptive changes in a propellant tank design and use in a spacecraft. Ground testing together with real-time slosh force data will allow an improved tank design to minimize and mitigate slosh forces, while at the same time keeping the tank mass to a minimum. Fully instrumented Smart Tanks will be able to provide force vector inputs to a spacecraft inertial navigation system; this in turn will (i eliminate or reduce navigational errors, (ii reduce wait time for uncertain slosh settling, since actual slosh forces will be known, and (iii simplify slosh control hardware, hence reducing overall mass. ECT may be well suited to space borne liquid measurement applications. Measurements are independent of and unaffected by orientation or levels of g. The electronics and sensor arrays can be low in mass, and critically, the technique does not dissipate heat into the propellant, which makes it intrinsically safe and suitable for cryogenic liquids. Because of the limitations of operating in earth-bound gravity, it has not been possible to check the exact numerical accuracy of the slosh force acting on the vessel. We are therefore in the process of undertaking a further project to (i build a prototype integrated “Smart Tank for Space”, (ii undertake slosh tests in zero or microgravity, (iii develop the system for commercial ground testing, and (iv qualify ECT for use in space.

  17. Reliable intraocular pressure measurement using automated radio-wave telemetry.

    Science.gov (United States)

    Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B

    2014-01-01

    To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.

  18. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Science.gov (United States)

    Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B

    2014-01-01

    Purpose To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. Methods The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. Results On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. Conclusion IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results. PMID:24531415

  19. Reliability and Validity of the Behavioral Addiction Measure for Video Gaming.

    Science.gov (United States)

    Sanders, James L; Williams, Robert J

    2016-01-01

    Most tests of video game addiction have weak construct validity and limited ability to correctly identify people in denial. The purpose of the present research was to investigate the reliability and validity of a new test of video game addiction (Behavioral Addiction Measure-Video Gaming [BAM-VG]) that was developed in part to address these deficiencies. Regular adult video gamers (n = 506) were recruited from a Canadian online panel and completed a survey containing three measures of excessive video gaming (BAM-VG; DSM-5 criteria for Internet Gaming Disorder [IGD]; and the IGD-20), as well as questions concerning extensiveness of video game involvement and self-report of problems associated with video gaming. One month later, they were reassessed for the purposes of establishing test-retest reliability. The BAM-VG demonstrated good internal consistency as well as 1 month test-retest reliability. Criterion-related validity was demonstrated by significant correlations with the following: time spent playing, self-identification of video game problems, and scores on other instruments designed to assess video game addiction (DSM-5 IGD, IGD-20). Consistent with the theory, principal component analysis identified two components underlying the BAM-VG that roughly correspond with impaired control and significant negative consequences deriving from this impaired control. Together with its excellent construct validity and other technical features, the BAM-VG represents a reliable and valid test of video game addiction.

  20. Methodology for interpretation of fissile mass flow measurements

    International Nuclear Information System (INIS)

    March-Leuba, J.; Mattingly, J.K.; Mullens, J.A.

    1997-01-01

    This paper describes a non-intrusive measurement technique to monitor the mass flow rate of fissile material in gaseous or liquid streams. This fissile mass flow monitoring system determines the fissile mass flow rate by relying on two independent measurements: (1) a time delay along a given length of pipe, which is inversely proportional to the fissile material flow velocity, and (2) an amplitude measurement, which is proportional to the fissile concentration (e.g., grams of 235 U per length of pipe). The development of this flow monitor was first funded by DOE/NE in September 95, and initial experimental demonstration by ORNL was described in the 37th INMM meeting held in July 1996. This methodology was chosen by DOE/NE for implementation in November 1996; it has been implemented in hardware/software and is ready for installation. This paper describes the methodology used to interpret the data measured by the fissile mass flow monitoring system and the models used to simulate the transport of fission fragments from the source location to the detectors

  1. Precise mass measurements of exotic nuclei--the SHIPTRAP Penning trap mass spectrometer

    International Nuclear Information System (INIS)

    Herfurth, F.; Ackermann, D.; Block, M.; Dworschak, M.; Eliseev, S.; Hessberger, F.; Hofmann, S.; Kluge, H.-J.; Maero, G.; Martin, A.; Mazzocco, M.; Rauth, C.; Vorobjev, G.; Blaum, K.; Ferrer, R.; Neidherr, D.; Chaudhuri, A.; Marx, G.; Schweikhard, L.; Neumayr, J.

    2007-01-01

    The SHIPTRAP Penning trap mass spectrometer has been designed and constructed to measure the mass of short-lived, radioactive nuclei. The radioactive nuclei are produced in fusion-evaporation reactions and separated in flight with the velocity filter SHIP at GSI in Darmstadt. They are captured in a gas cell and transfered to a double Penning trap mass spectrometer. There, the cyclotron frequencies of the radioactive ions are determined and yield mass values with uncertainties ≥4.5·10 -8 . More than 50 nuclei have been investigated so far with the present overall efficiency of about 0.5 to 2%

  2. The reliability and validity of hand-held refractometry water content measures of hydrogel lenses.

    Science.gov (United States)

    Nichols, Jason J; Mitchell, G Lynn; Good, Gregory W

    2003-06-01

    To investigate within- and between-examiner reliability and validity of hand-held refractometry water content measures of hydrogel lenses. Nineteen lenses of various nominal water contents were examined by two examiners on two occasions separated by 1 hour. An Atago N2 hand-held refractometer was used for all water content measures. Lenses were presented in a random order to each examiner by a third party, and examiners were masked to any potential lens identifiers. Intraclass correlation coefficients (ICC), 95% limits of agreement, and Wilcoxon signed rank test were used to characterize the within- and between-examiner reliability and validity of lens water content measures. Within-examiner reliability was excellent (ICC, 0.97; 95% limits of agreement, -3.6% to +5.7%), and the inter-visit mean difference of 1.1 +/- 2.4% was not biased (p = 0.08). Between-examiner reliability was also excellent (ICC, 0.98; 95% limits of agreement, -4.1% to +3.9%). The mean difference between examiners was -0.1 +/- 2.1% (p = 0.83). The mean difference between the nominally reported water content and our water content measures was -2.1 +/- 1.7% (p refractometry and is material dependent. Therefore, investigators may need to account for bias when measuring hydrogel lens water content via hand-held refractometry.

  3. Measuring awareness of financial skills: reliability and validity of a new measure.

    Science.gov (United States)

    Cramer, K; Tuokko, H A; Mateer, C A; Hultsch, D F

    2004-03-01

    This paper examines the psychometric properties of a three-part (participant, informant, and performance) Measure for assessing Awareness of Financial Skills (MAFS). The MAFS was administered to 10 seniors with dementia and 25 well-functioning seniors, and their informants. Measures of cognitive functioning, social desirability, neuroticism, and perceived control were administered to each participant to allow for an assessment of validity. Internal consistency estimates for the participant and informant questionnaires were found to be 0.92 and 0.97, respectively. Convergent validity analysis indicated that performance on this measure was related to level of cognitive functioning, with higher level of unawareness associated with decreased cognitive ability. Discriminant validity analysis showed that performance on this measure was not related to social desirability or neuroticism. This study provides evidence that the MAFS is a reliable and valid tool for assessing awareness of financial skills in older adults.

  4. Reliability and validity of the ultrasound technique to measure the rectus femoris muscle diameter in older CAD-patients

    Directory of Open Access Journals (Sweden)

    Thomaes Tom

    2012-04-01

    Full Text Available Abstract Background The increasing age of coronary artery disease (CAD patients and the occurrence of sarcopenia in the elderly population accompanied by 'fear of moving' and hospitalization in these patients often results in a substantial loss of skeletal muscle mass and muscle strength. Cardiac rehabilitation can improve exercise tolerance and muscle strength in CAD patients but less data describe eventual morphological muscular changes possibly by more difficult access to imaging techniques. Therefore the aim of this study is to assess and quantify the reliability and validity of an easy applicable method, the ultrasound (US technique, to measure the diameter of rectus femoris muscle in comparison to the muscle dimensions measured with CT scans. Methods 45 older CAD patients without cardiac event during the last 9 months were included in this study. 25 patients were tested twice with ultrasound with a two day interval to assess test-retest reliability and 20 patients were tested twice (once with US and once with CT on the same day to assess the validity of the US technique compared to CT as the gold standard. Isometric and isokinetic muscle testing was performed to test potential zero-order correlations between muscle diameter, muscle volume and muscle force. Results An intraclass correlation coefficient (ICC of 0.97 ((95%CL: 0.92 - 0.99 was found for the test-retest reliability of US and the ICC computed between US and CT was 0.92 (95%CL: 0.81 - 0.97. The absolute difference between both techniques was 0.01 ± 0.12 cm (p = 0.66 resulting in a typical percentage error of 4.4%. Significant zero-order correlations were found between local muscle volume and muscle diameter assessed with CT (r = 0.67, p = 0.001 and assessed with US (r = 0.49, p Conclusions Ultrasound imaging can be used as a valid and reliable measurement tool to assess the rectus femoris muscle diameter in older CAD patients.

  5. CLASSIFYING BENIGN AND MALIGNANT MASSES USING STATISTICAL MEASURES

    Directory of Open Access Journals (Sweden)

    B. Surendiran

    2011-11-01

    Full Text Available Breast cancer is the primary and most common disease found in women which causes second highest rate of death after lung cancer. The digital mammogram is the X-ray of breast captured for the analysis, interpretation and diagnosis. According to Breast Imaging Reporting and Data System (BIRADS benign and malignant can be differentiated using its shape, size and density, which is how radiologist visualize the mammograms. According to BIRADS mass shape characteristics, benign masses tend to have round, oval, lobular in shape and malignant masses are lobular or irregular in shape. Measuring regular and irregular shapes mathematically is found to be a difficult task, since there is no single measure to differentiate various shapes. In this paper, the malignant and benign masses present in mammogram are classified using Hue, Saturation and Value (HSV weight function based statistical measures. The weight function is robust against noise and captures the degree of gray content of the pixel. The statistical measures use gray weight value instead of gray pixel value to effectively discriminate masses. The 233 mammograms from the Digital Database for Screening Mammography (DDSM benchmark dataset have been used. The PASW data mining modeler has been used for constructing Neural Network for identifying importance of statistical measures. Based on the obtained important statistical measure, the C5.0 tree has been constructed with 60-40 data split. The experimental results are found to be encouraging. Also, the results will agree to the standard specified by the American College of Radiology-BIRADS Systems.

  6. Characterizing uranium oxide reference particles for isotopic abundances and uranium mass by single particle isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Kraiem, M.; Richter, S.; Erdmann, N.; Kühn, H.; Hedberg, M.; Aregbe, Y.

    2012-01-01

    Highlights: ► A method to quantify the U mass in single micron particles by ID-TIMS was developed. ► Well-characterized monodisperse U-oxide particles produced by an aerosol generator were used. ► A linear correlation between the mass of U and the volume of particle(s) was found. ► The method developed is suitable for determining the amount of U in a particulate reference material. - Abstract: Uranium and plutonium particulate test materials are becoming increasingly important as the reliability of measurement results has to be demonstrated to regulatory bodies responsible for maintaining effective nuclear safeguards. In order to address this issue, the Institute for Reference Materials and Measurements (IRMM) in collaboration with the Institute for Transuranium Elements (ITU) has initiated a study to investigate the feasibility of preparing and characterizing a uranium particle reference material for nuclear safeguards, which is finally certified for isotopic abundances and for the uranium mass per particle. Such control particles are specifically required to evaluate responses of instruments based on mass spectrometric detection (e.g. SIMS, TIMS, LA-ICPMS) and to help ensuring the reliability and comparability of measurement results worldwide. In this paper, a methodology is described which allows quantifying the uranium mass in single micron particles by isotope dilution thermal ionization mass spectrometry (ID-TIMS). This methodology is characterized by substantial improvements recently achieved at IRMM in terms of sensitivity and measurement accuracy in the field of uranium particle analysis by TIMS. The use of monodisperse uranium oxide particles prepared using an aerosol generation technique developed at ITU, which is capable of producing particles of well-characterized size and isotopic composition was exploited. The evidence of a straightforward correlation between the particle volume and the mass of uranium was demonstrated in this study

  7. Development and reliability testing of a food store observation form.

    Science.gov (United States)

    Rimkus, Leah; Powell, Lisa M; Zenk, Shannon N; Han, Euna; Ohri-Vachaspati, Punam; Pugach, Oksana; Barker, Dianne C; Resnick, Elissa A; Quinn, Christopher M; Myllyluoma, Jaana; Chaloupka, Frank J

    2013-01-01

    To develop a reliable food store observational data collection instrument to be used for measuring product availability, pricing, and promotion. Observational data collection. A total of 120 food stores (26 supermarkets, 34 grocery stores, 54 gas/convenience stores, and 6 mass merchandise stores) in the Chicago metropolitan statistical area. Inter-rater reliability for product availability, pricing, and promotion measures on a food store observational data collection instrument. Cohen's kappa coefficient and proportion of overall agreement for dichotomous variables and intra-class correlation coefficient for continuous variables. Inter-rater reliability, as measured by average kappa coefficient, was 0.84 for food and beverage product availability measures, 0.80 for interior store characteristics, and 0.70 for exterior store characteristics. For continuous measures, average intra-class correlation coefficient was 0.82 for product pricing measures; 0.90 for counts of fresh, frozen, and canned fruit and vegetable options; and 0.85 for counts of advertisements on the store exterior and property. The vast majority of measures demonstrated substantial or almost perfect agreement. Although some items may require revision, results suggest that the instrument may be used to reliably measure the food store environment. Copyright © 2013 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  8. Mass measurement of halo nuclides and beam cooling with the mass spectrometer Mistral

    International Nuclear Information System (INIS)

    Bachelet, C.

    2004-12-01

    Halo nuclides are a spectacular drip-line phenomenon and their description pushes nuclear theories to their limits. The most critical input parameter is the nuclear binding energy; a quantity that requires excellent measurement precision, since the two-neutron separation energy is small at the drip-line by definition. Moreover halo nuclides are typically very short-lived. Thus, a high accuracy instrument using a quick method of measurement is necessary. MISTRAL is such an instrument; it is a radiofrequency transmission mass spectrometer located at ISOLDE/CERN. In July 2003 we measured the mass of the Li 11 , a two-neutron halo nuclide. Our measurement improves the precision by a factor 6, with an error of 5 keV. Moreover the measurement gives a two-neutron separation energy 20% higher than the previous value. This measurement has an impact on the radius of the nucleus, and on the state of the two valence neutrons. At the same time, a measurement of the Be 11 was performed with an uncertainty of 4 keV, in excellent agreement with previous measurements. In order to measure the mass of the two-neutron halo nuclide Be 14 , an ion beam cooling system is presently under development which will increase the sensitivity of the spectrometer. The second part of this work presents the development of this beam cooler using a gas-filled Paul trap. (author)

  9. Reliability and Accuracy of Brain Volume Measurement on MR Imaging

    DEFF Research Database (Denmark)

    Yamagchii, Kechiro; Lassen, Anders; Ring, Poul

    1998-01-01

    Yamaguchi, K., Lassen, A. And Ring, P. Reliability and Accuracy of Brain Volume Measurement on MR Imaging. Abstract at ESMRMB98 European Society for Magnetic Resonance in Medicine and Biology, Geneva, Sept 17-20, 1998 Danish Research Center for Magnetic Resonance, Hvidovre University Hospital...

  10. Reliability of the craniocervical posture assessment: visual and angular measurements using photographs and radiographs.

    Science.gov (United States)

    Gadotti, Inae C; Armijo-Olivo, Susan; Silveira, Anelise; Magee, David

    2013-01-01

    The purposes of this study were to determine the intrarater and interrater reliability of the craniocervical posture in a sagittal view using quantitative measurements on photographs and radiographs and to determine the agreement of the visual assessment of posture between raters. One photograph and 1 radiograph of the sagittal craniocervical posture were simultaneously taken from 39 healthy female subjects. Three angles were measured on the photographs and 10 angles on the radiographs of 22 subjects using Alcimage software (Alcimage; Uberlândia, MG, Brazil). Two repeated measurements were performed by 2 raters. The measurements were compared within and between raters to test the intrarater and interrater reliability, respectively. Intraclass correlation coefficient and SEM were used. κ Agreement was calculated for the visual assessment of 39 subjects using photographs and radiographs between 2 raters. Good to excellent intrarater and interrater intraclass correlation coefficient values were found on both photographs and radiographs. Interrater SEM was large and clinically significant for cervical lordosis photogrammetry and for 1 angle measuring cervical lordosis on radiographs. Interrater κ agreement for the visual assessment using photographs was poor (κ = 0.37). The raters were reliable to measure angles in photographs and radiographs to quantify craniocervical posture with exception of 2 angles measuring lordosis of the cervical spine when compared between raters. The visual assessment of posture between raters was not reliable. © 2013. Published by National University of Health Sciences All rights reserved.

  11. Measurement of the W boson mass at LEP

    CERN Document Server

    D'Hondt, J

    2003-01-01

    The mass of the W boson has been measured by all LEP experiment by the method of diret reonstrution in the WW deay hannels where at least one W boson deays hadronially. This preision measurement is inuened by many systemati unertainties whih were extensively studied. One example is the possible eet of Colour Reonnetion between the deay produts from dierent W bosons in fully hadroni WW nal states. These proeedings overview the preliminary results onerning the W mass measurement and the ongoing measurements of the Colour Reonnetion eet.

  12. Reliability Measure Model for Assistive Care Loop Framework Using Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Venki Balasubramanian

    2010-01-01

    Full Text Available Body area wireless sensor networks (BAWSNs are time-critical systems that rely on the collective data of a group of sensor nodes. Reliable data received at the sink is based on the collective data provided by all the source sensor nodes and not on individual data. Unlike conventional reliability, the definition of retransmission is inapplicable in a BAWSN and would only lead to an elapsed data arrival that is not acceptable for time-critical application. Time-driven applications require high data reliability to maintain detection and responses. Hence, the transmission reliability for the BAWSN should be based on the critical time. In this paper, we develop a theoretical model to measure a BAWSN's transmission reliability, based on the critical time. The proposed model is evaluated through simulation and then compared with the experimental results conducted in our existing Active Care Loop Framework (ACLF. We further show the effect of the sink buffer in transmission reliability after a detailed study of various other co-existing parameters.

  13. New Directions in Mass Communications Research: Physiological Measurement.

    Science.gov (United States)

    Fletcher, James E.

    Psychophysiological research into the effects of mass media, specifically the music of the masses, promises increased insight into the control the media exert on all their consumers. Attention and retention of mass media messages can be tested by measuring the receiver's electrodernal activity, pupil dilation, peripheral vasodilation, and heart…

  14. Mass and Charge Measurements on Heavy Ions

    Science.gov (United States)

    Sugai, Toshiki

    2017-01-01

    The relationship between mass and charge has been a crucial topic in mass spectrometry (MS) because the mass itself is typically evaluated based on the m/z ratio. Despite the fact that this measurement is indirect, a precise mass can be obtained from the m/z value with a high m/z resolution up to 105 for samples in the low mass and low charge region under 10,000 Da and 20 e, respectively. However, the target of MS has recently been expanded to the very heavy region of Mega or Giga Da, which includes large particles and biocomplexes, with very large and widely distributed charge from kilo to Mega range. In this region, it is necessary to evaluate charge and mass simultaneously. Recent studies for simultaneous mass and charge observation and related phenomena are discussed in this review. PMID:29302406

  15. Reliability of isometric lower-extremity muscle strength measurements in children with cerebral palsy: implications for measurement design

    NARCIS (Netherlands)

    Willemse, Lydia; Brehm, Merel A.; Scholtes, Vanessa A.; Jansen, Laura; Woudenberg-Vos, Hester; Dallmeijer, Annet J.

    2013-01-01

    Children with cerebral palsy (CP) typically show muscle weakness of the lower extremities, which can be measured with the use of handheld dynamometry (HHD). The purposes of this study were: (1) to determine test-retest reliability and measurement error of isometric lower-extremity strength

  16. Reliability of Instruments Measuring At-Risk and Problem Gambling Among Young Individuals

    DEFF Research Database (Denmark)

    Edgren, Robert; Castrén, Sari; Mäkelä, Marjukka

    2016-01-01

    This review aims to clarify which instruments measuring at-risk and problem gambling (ARPG) among youth are reliable and valid in light of reported estimates of internal consistency, classification accuracy, and psychometric properties. A systematic search was conducted in PubMed, Medline, and Psyc......Info covering the years 2009–2015. In total, 50 original research articles fulfilled the inclusion criteria: target age under 29 years, using an instrument designed for youth, and reporting a reliability estimate. Articles were evaluated with the revised Quality Assessment of Diagnostic Accuracy Studies tool....... Reliability estimates were reported for five ARPG instruments. Most studies (66%) evaluated the South Oaks Gambling Screen Revised for Adolescents. The Gambling Addictive Behavior Scale for Adolescents was the only novel instrument. In general, the evaluation of instrument reliability was superficial. Despite...

  17. Precision measurement of the Ds*+-Ds+ mass difference

    International Nuclear Information System (INIS)

    Brown, D.N.; Fast, J.; McIlwain, R.L.; Miao, T.; Miller, D.H.; Modesitt, M.; Payne, D.; Shibata, E.I.; Shipsey, I.P.J.; Wang, P.N.; Battle, M.; Ernst, J.; Kwon, Y.; Roberts, S.; Thorndike, E.H.; Wang, C.H.; Dominick, J.; Lambrecht, M.; Sanghera, S.; Shelkov, V.; Skwarnicki, T.; Stroynowski, R.; Volobouev, I.; Wei, G.; Zadorozhny, P.; Artuso, M.; Goldberg, M.; He, D.; Horwitz, N.; Kennett, R.; Mountain, R.; Moneti, G.C.; Muheim, F.; Mukhin, Y.; Playfer, S.; Rozen, Y.; Stone, S.; Thulasidas, M.; Vasseur, G.; Zhu, G.; Bartelt, J.; Csorna, S.E.; Egyed, Z.; Jain, V.; Kinoshita, K.; Edwards, K.W.; Ogg, M.; Britton, D.I.; Hyatt, E.R.F.; MacFarlane, D.B.; Patel, P.M.; Akerib, D.S.; Barish, B.; Chadha, M.; Chan, S.; Cowen, D.F.; Eigen, G.; Miller, J.S.; O'Grady, C.; Urheim, J.; Weinstein, A.J.; Acosta, D.; Athanas, M.; Masek, G.; Paar, H.P.; Gronberg, J.; Kutschke, R.; Menary, S.; Morrison, R.J.; Nakanishi, S.; Nelson, H.N.; Nelson, T.K.; Qiao, C.; Richman, J.D.; Ryd, A.; Tajima, H.; Sperka, D.; Witherell, M.S.; Procario, M.; Balest, R.; Cho, K.; Daoudi, M.; Ford, W.T.; Johnson, D.R.; Lingel, K.; Lohner, M.; Rankin, P.; Smith, J.G.; Alexander, J.P.; Bebek, C.; Berkelman, K.; Bloom, K.; Browder, T.E.; Cassel, D.G.; Cho, H.A.; Coffman, D.M.; Drell, P.S.; Ehrlich, R.; Gaiderev, P.; Garcia-Sciveres, M.; Geiser, B.; Gittelman, B.; Gray, S.W.; Hartill, D.L.; Heltsley, B.K.; Jones, C.D.; Jones, S.L.; Kandaswamy, J.; Katayama, N.; Kim, P.C.; Kreinick, D.L.; Ludwig, G.S.; Masui, J.; Mevissen, J.; Mistry, N.B.; Ng, C.R.; Nordberg, E.; Patterson, J.R.; Peterson, D.; Riley, D.; Salman, S.; Sapper, M.; Wuerthwein, F.; Avery, P.; Freyberger, A.; Rodriguez, J.; Stephens, R.; Yang, S.; Yelton, J.; Cinabro, D.; Henderson, S.; Liu, T.; Saulnier, M.; Wilson, R.; Yamamoto, H.; Bergfeld, T.; Eisenstein, B.I.; Gollin, G.; Ong, B.; Palmer, M.; Selen, M.; Thaler, J.; Sadoff, A.J.; Ammar, R.; Ball, S.; Baringer, P.; Bean, A.; Besson, D.; Coppage, D.; Copty, N.; Davis, R.; Hancock, N.

    1994-01-01

    We have measured the vector-pseudoscalar mass splitting M(D s *+ )-M(D s + )=144.22±0.47±0.37 MeV significantly more precisely than the previous world average. We minimize the systematic errors by also measuring the vector-pseudoscalar mass difference M(D *0 )-M(D 0 ) using the radiative decay D *0 →D 0 γ, obtaining [M(D s *+ )-M(D s + )]-[M(D *0 )-M(D 0 )] =2.09±0.47±0.37 MeV. This is then combined with our previous high-precision measurement of M(D *0 )-M(D 0 ), which used the decay D *0 →D 0 π 0 . We also measure the mass difference M(D s + )-M(D + )=99.5±0.6±0.3 MeV, using the φπ + decay modes of the D s + and D + mesons

  18. Continuous Mass Measurement on Conveyor Belt

    Science.gov (United States)

    Tomobe, Yuki; Tasaki, Ryosuke; Yamazaki, Takanori; Ohnishi, Hideo; Kobayashi, Masaaki; Kurosu, Shigeru

    The continuous mass measurement of packages on a conveyor belt will become greatly important. In the mass measurement, the sequence of products is generally random. An interesting possibility of raising throughput of the conveyor line without increasing the conveyor belt speed is offered by the use of two or three conveyor belt scales (called a multi-stage conveyor belt scale). The multi-stage conveyor belt scale can be created which will adjust the conveyor belt length to the product length. The conveyor belt scale usually has maximum capacities of less than 80kg and 140cm, and achieves measuring rates of more than 150 packages per minute and more. The output signals from the conveyor belt scale are always contaminated with noises due to vibrations of the conveyor and the product to be measured in motion. In this paper an employed digital filter is of Finite Impulse Response (FIR) type designed under the consideration on the dynamics of the conveyor system. The experimental results on the conveyor belt scale suggest that the filtering algorithms are effective enough to practical applications to some extent.

  19. Reliability of Using Motion Sensors to Measure Children’s Physical Activity Levels in Exergaming

    Directory of Open Access Journals (Sweden)

    Nan Zeng

    2018-05-01

    Full Text Available Objectives: This study examined the reliability of two objective measurement tools in assessing children’s physical activity (PA levels in an exergaming setting. Methods: A total of 377 children (190 girls, Mage = 8.39, SD = 1.55 attended the 30-min exergaming class every other day for 18 weeks. Children’s PA levels were concurrently measured by NL-1000 pedometer and ActiGraph GT3X accelerometer, while children’s steps per min and time engaged in sedentary, light, and moderate-to-vigorous PA were estimated, respectively. Results: The results of intraclass correlation coefficient (ICC indicated a low degree of reliability (single measures ICC = 0.03 in accelerometers. ANOVA did detect a possible learning effect for 27 classes (p < 0.01, and the single measures ICC was 0.20 for pedometers. Moreover, there was no significant positive relationship between steps per min and time spent in moderate-to-vigorous physical activity (MVPA. Finally, only 1.3% variance was explained by pedometer as a predictor using Hierarchical Linear Modeling to further explore the relationship between pedometer and accelerometer data. Conclusions: The NL-1000 pedometers and ActiGraph GT3X accelerometers have low reliability in assessing elementary school children’s PA levels during exergaming. More research is warranted in determining the reliable and accurate measurement information regarding the use of modern devices in exergaming setting.

  20. Supersonic shear imaging provides a reliable measurement of resting muscle shear elastic modulus

    International Nuclear Information System (INIS)

    Lacourpaille, Lilian; Hug, François; Bouillard, Killian; Nordez, Antoine; Hogrel, Jean-Yves

    2012-01-01

    The aim of the present study was to assess the reliability of shear elastic modulus measurements performed using supersonic shear imaging (SSI) in nine resting muscles (i.e. gastrocnemius medialis, tibialis anterior, vastus lateralis, rectus femoris, triceps brachii, biceps brachii, brachioradialis, adductor pollicis obliquus and abductor digiti minimi) of different architectures and typologies. Thirty healthy subjects were randomly assigned to the intra-session reliability (n = 20), inter-day reliability (n = 21) and the inter-observer reliability (n = 16) experiments. Muscle shear elastic modulus ranged from 2.99 (gastrocnemius medialis) to 4.50 kPa (adductor digiti minimi and tibialis anterior). On the whole, very good reliability was observed, with a coefficient of variation (CV) ranging from 4.6% to 8%, except for the inter-operator reliability of adductor pollicis obliquus (CV = 11.5%). The intraclass correlation coefficients were good (0.871 ± 0.045 for the intra-session reliability, 0.815 ± 0.065 for the inter-day reliability and 0.709 ± 0.141 for the inter-observer reliability). Both the reliability and the ease of use of SSI make it a potentially interesting technique that would be of benefit to fundamental, applied and clinical research projects that need an accurate assessment of muscle mechanical properties. (note)

  1. High Precision Atomic Mass Measurements: Tests of CVC and IMME

    International Nuclear Information System (INIS)

    Eronen, Tommi

    2011-01-01

    Atomic mass is one of the key ingredients in testing the Conserved Vector Current (CVC) hypothesis and Isobaric Mass Multiplet Equation (IMME). With JYFLTRAP Penning trap installation at the University of Jyvaeskylae, Finland, several atomic massses related to these studies have been measured. The performed atomic mass measurements for CVC tests cover almost all the nuclei that are relevant for these studies. To test IMME, masses in two isobaric mass chains (A = 23 and A = 32) have been determined.

  2. High Precision Atomic Mass Measurements: Tests of CVC and IMME

    Energy Technology Data Exchange (ETDEWEB)

    Eronen, Tommi [Department of Physics, University of Jyvaeskylae, FI-40014 University of Jyvaeskylae (Finland); Collaboration: JYFLTRAP Collaboration

    2011-11-30

    Atomic mass is one of the key ingredients in testing the Conserved Vector Current (CVC) hypothesis and Isobaric Mass Multiplet Equation (IMME). With JYFLTRAP Penning trap installation at the University of Jyvaeskylae, Finland, several atomic massses related to these studies have been measured. The performed atomic mass measurements for CVC tests cover almost all the nuclei that are relevant for these studies. To test IMME, masses in two isobaric mass chains (A = 23 and A = 32) have been determined.

  3. Precise mass measurements of astrophysical interest made with the Canadian Penning trap mass spectrometer

    International Nuclear Information System (INIS)

    Clark, J.A.; Barber, R.C.; Blank, B.; Boudreau, C.; Buchinger, F.; Crawford, J.E.; Gulick, S.; Hardy, J.C.; Heinz, A.; Lee, J.K.P.; Levand, A.F.; Moore, R.B.; Savard, G.; Seweryniak, D.; Sharma, K.S.; Sprouse, G.D.; Trimble, W.; Vaz, J.; Wang, J.C.; Zhou, Z.

    2004-01-01

    The processes responsible for the creation of elements more massive than iron are not well understood. Possible production mechanisms involve the rapid capture of protons (rp-process) or the rapid capture of neutrons (r-process), which are thought to occur in explosive astrophysical events such as novae, x-ray bursts, and supernovae. Mass measurements of the nuclides involved with uncertainties on the order of 100 keV or better are critical to determine the process 'paths', the energy output of the events, and the resulting nuclide abundances. Particularly important are the masses of 'waiting-point' nuclides along the rp-process path where the process stalls until the subsequent β decay of the nuclides. This paper will discuss the precise mass measurements made of isotopes along the rp-process and r-process paths using the Canadian Penning Trap mass spectrometer, including the mass of the critical waiting-point nuclide 68 Se

  4. How to measure distinct components of visual attention fast and reliably

    DEFF Research Database (Denmark)

    Vangkilde, Signe Allerup; Kyllingsbæk, Søren; Habekost, Thomas

    2009-01-01

    Measuring different attentional processes in a fast and reliable way is important in both clinical and experimental settings. However, most tests of visual attention are either lengthy or lack sensitivity, specificity, and reliability. To address this we developed a ten minute test procedure...... for the Swedish Betula-project, a longitudinal study investigating changes in cognitive functions over the adult life span (Nilsson et al., 2004). The test consists of a computer-based letter recognition task with stimulus displays of varied durations followed by pattern masks or a blank screen. The temporal...

  5. Reliability and responsiveness of algometry for measuring pressure pain threshold in patients with knee osteoarthritis.

    Science.gov (United States)

    Mutlu, Ebru Kaya; Ozdincler, Arzu Razak

    2015-06-01

    [Purpose] This study aimed to establish the intrarater reliability and responsiveness of a clinically available algometer in patients with knee osteoarthritis as well as to determine the minimum-detectable-change and standard error of measurement of testing to facilitate clinical interpretation of temporal changes. [Subjects] Seventy-three patients with knee osteoarthritis were included. [Methods] Pressure pain threshold measured by algometry was evaluated 3 times at 2-min intervals over 2 clinically relevant sites-mediolateral to the medial femoral tubercle (distal) and lateral to the medial malleolus (local)-on the same day. Intrarater reliability was estimated by intraclass correlation coefficients. The minimum-detectable-change and standard error of measurement were calculated. As a measure of responsiveness, the effect size was calculated for the results at baseline and after treatment. [Results] The intrarater reliability was almost perfect (intraclass correlation coefficient = 0.93-0.97). The standard error of measurement and minimum-detectable-change were 0.70-0.66 and 1.62-1.53, respectively. The pressure pain threshold over the distal site was inadequately responsive in knee osteoarthritis, but the local site was responsive. The effect size was 0.70. [Conclusion] Algometry is reliable and responsive to assess measures of pressure pain threshold for evaluating pain patients with knee osteoarthritis.

  6. Recent progress in precision mass measurements

    International Nuclear Information System (INIS)

    Kluge, H.J.; Heidelberg Univ.

    1995-09-01

    During the last years, a new generation of technique for measuring directly masses of short-lived isotopes has evolved. The common features of these modern techniques are a transition from the measurement of kinetic energies or voltage ratios to a determination of time and frequency and in most cases storage of the ions for extended periods of time. (orig.)

  7. Evaluations of particulate mass loading from visibility observations and atmospheric turbidity measurements: Pt. 1

    International Nuclear Information System (INIS)

    Tomasi, C.; Vitale, V.

    1984-01-01

    Two extinction models for continental and rural particles were defined by using a very accurate computer programme based on Mie extinction theory for spherical particles. The first extinction model gives several sets of volume extinction coefficients at seven visible and near-infra-red wave-lengths, calculated for twenty-seven Junge-type size distribution curves (with Junge parameter ranging from 1.8 to 4.4) and for eight relative-humidity values of the air. This model also gives the corresponding values of Aangstroem's exponent α and mean particle mass. The second extinction model gives similar sets of data, calculated for two log-normal size distribution curves of tropospheric and large rural particles at five relative-humidity values of the air. These monomodal models can be used to determine bimodal extinction models consisting of variable number fractions of tropospherics and rural particles. Evaluations of the particulate mass loading can be obtained from measurements of visual range and atmospheric turbidity, choosing the most appropriate extinction model on the basis of the spectral features characterizing atmospheric attenuation. Measurements of visibility and atmospheric turbidity in two rural localities of the Po valley were examined by employing both the present extinction models and other extinction models commonly used. The comparison of the results shows that the Junge-type extinction model can be reliably used in cases in which the exponent Junge-type extinction model and bimodal model were found to give realistic evaluations of the lower and upper limits of particulate mass loading

  8. Measuring protein synthesis using metabolic ²H labeling, high-resolution mass spectrometry, and an algorithm.

    Science.gov (United States)

    Kasumov, Takhar; Ilchenko, Serguey; Li, Ling; Rachdaoui, Nadia; Sadygov, Rovshan G; Willard, Belinda; McCullough, Arthur J; Previs, Stephen

    2011-05-01

    We recently developed a method for estimating protein dynamics in vivo with heavy water ((2)H(2)O) using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) [16], and we confirmed that (2)H labeling of many hepatic free amino acids rapidly equilibrated with body water. Although this is a reliable method, it required modest sample purification and necessitated the determination of tissue-specific amino acid labeling. Another approach for quantifying protein kinetics is to measure the (2)H enrichments of body water (precursor) and protein-bound amino acid or proteolytic peptide (product) and to estimate how many copies of deuterium are incorporated into a product. In the current study, we used nanospray linear trap Fourier transform ion cyclotron resonance mass spectrometry (LTQ FT-ICR MS) to simultaneously measure the isotopic enrichment of peptides and protein-bound amino acids. A mathematical algorithm was developed to aid the data processing. The most notable improvement centers on the fact that the precursor/product labeling ratio can be obtained by measuring the labeling of water and a protein (or peptide) of interest, thereby minimizing the need to measure the amino acid labeling. As a proof of principle, we demonstrate that this approach can detect the effect of nutritional status on albumin synthesis in rats given (2)H(2)O. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Magnetic resonance imaging of shoulders with idiopathic adhesive capsulitis: reliability of measures

    Energy Technology Data Exchange (ETDEWEB)

    Lefevre-Colau, Marie-Martine; Fayad, Fouad; Rannou, Francois; Demaille-Wlodyka, Samantha; Mayoux-Benhamou, Marie-Anne; Poiraudeau, Serge; Revel, Michel [Universite Rene Descartes, Department of Physical and Rehabilitation Medicine, Hopital Cochin (AP-HP), Paris (France); Drape, Jean-Luc; Diche, Thierry; Minvielle, Francois [Hopital Cochin (AP-HP), Department of Radiology B, Paris (France); Fermanian, Jacques [Universite Rene Descartes, Department of Biostatistics, Hopital Necker (AP-HP), Paris (France)

    2005-12-01

    The magnetic resonance imaging (MRI) findings in idiopathic adhesive capsulitis (AC) were compared with those of contralateral healthy shoulders and the reliability of measures assessed. Twenty-six consecutive patients (26 AC and 14 healthy shoulders) were prospectively assessed. The main measurements were thickness of the joint capsule and synovial membrane in the axillary recess and rotator interval in T1-weighted spin-echo sequence enhanced with intravenous (IV) gadolinium chelate (Gd-chelate). Reliability was studied by use of the intraclass correlation coefficient (ICC). The mean thickness of the axillary recess on the coronal plane was 9.0{+-}2.2 mm in AC shoulders and 0.4{+-}0.7 mm in healthy shoulders. The mean thickness of the rotator interval on the sagittal plane was 8.4{+-}2.8 in AC shoulders and 0.6{+-}0.8 mm in healthy shoulders. Interobserver reliability was good for the axillary recess, with ICC values of 0.84 for the coronal plane, and good for the rotator interval, with ICC values of 0.80 for the sagittal plane. MRI with IV Gd-chelate injection can show, with acceptable reliability, signal and thickness abnormalities of the shoulder joint capsule and synovial membrane in AC. (orig.)

  10. Magnetic resonance imaging of shoulders with idiopathic adhesive capsulitis: reliability of measures

    International Nuclear Information System (INIS)

    Lefevre-Colau, Marie-Martine; Fayad, Fouad; Rannou, Francois; Demaille-Wlodyka, Samantha; Mayoux-Benhamou, Marie-Anne; Poiraudeau, Serge; Revel, Michel; Drape, Jean-Luc; Diche, Thierry; Minvielle, Francois; Fermanian, Jacques

    2005-01-01

    The magnetic resonance imaging (MRI) findings in idiopathic adhesive capsulitis (AC) were compared with those of contralateral healthy shoulders and the reliability of measures assessed. Twenty-six consecutive patients (26 AC and 14 healthy shoulders) were prospectively assessed. The main measurements were thickness of the joint capsule and synovial membrane in the axillary recess and rotator interval in T1-weighted spin-echo sequence enhanced with intravenous (IV) gadolinium chelate (Gd-chelate). Reliability was studied by use of the intraclass correlation coefficient (ICC). The mean thickness of the axillary recess on the coronal plane was 9.0±2.2 mm in AC shoulders and 0.4±0.7 mm in healthy shoulders. The mean thickness of the rotator interval on the sagittal plane was 8.4±2.8 in AC shoulders and 0.6±0.8 mm in healthy shoulders. Interobserver reliability was good for the axillary recess, with ICC values of 0.84 for the coronal plane, and good for the rotator interval, with ICC values of 0.80 for the sagittal plane. MRI with IV Gd-chelate injection can show, with acceptable reliability, signal and thickness abnormalities of the shoulder joint capsule and synovial membrane in AC. (orig.)

  11. Reliability of ultrasound for measurement of selected foot structures.

    Science.gov (United States)

    Crofts, G; Angin, S; Mickle, K J; Hill, S; Nester, C J

    2014-01-01

    Understanding the relationship between the lower leg muscles, foot structures and function is essential to explain how disease or injury may relate to changes in foot function and clinical pathology. The aim of this study was to investigate the inter-operator reliability of an ultrasound protocol to quantify features of: rear, mid and forefoot sections of the plantar fascia (PF); flexor hallucis brevis (FHB); flexor digitorum brevis (FDB); abductor hallucis (AbH); flexor digitorum longus (FDL); flexor hallucis longus (FHL); tibialis anterior (TA); and peroneus longus and brevis (PER). A sample of 6 females and 4 males (mean age 29.1 ± 7.2 years, mean BMI 25.5 ± 4.8) was recruited from a university student and staff population. Scans were obtained using a portable Venue 40 musculoskeletal ultrasound system (GE Healthcare UK) with a 5-13 MHz wideband linear array probe with a 12.7 mm × 47.1mm footprint by two operators in the same scanning session. Intraclass Correlation Coefficients (ICC) values for muscle thickness (ICC range 0.90-0.97), plantar fascia thickness (ICC range 0.94-0.98) and cross sectional muscle measurements (ICC range 0.91-0.98) revealed excellent inter-operator reliability. The limits of agreement, relative to structure size, ranged from 9.0% to 17.5% for muscle thickness, 11.0-18.0% for plantar fascia, and 11.0-26.0% for cross sectional area measurements. The ultrasound protocol implemented in this work has been shown to be reliable. It therefore offers the opportunity to quantify the structures concerned and better understand their contributions to foot function. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  12. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    Science.gov (United States)

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  13. Mass measurements on short-lived Cd and Ag nuclides at the online mass spectrometer ISOLTRAP

    International Nuclear Information System (INIS)

    Breitenfeldt, Martin

    2009-01-01

    In the present work, mass determinations of the eleven neutron-deficient nuclides 99-109 Cd, of ten neutron-rich silver nuclides 112,114-121,123 Ag, and seven neutron-rich cadmium nuclides 114,120,122-124,126,128 Cd are reported. Due to the clean production of the neutron-deficient nuclides it was possible to reduce the experimental uncertainties down to 2 keV, whereas the measurements of neutron-rich nuclides were hampered by the presence of contaminations from more stable In and Cs nuclides. In the case of 99 Cd and 123 Ag the masses were determined for the first time and for the other nuclides the mass uncertainties could be reduced by up to a factor of 50 as in the case of 100 Cd. In the case of a potential isomeric mixture as for 115,117,119 Ag and 123 Cd, where no assignment to either the ground state or the excited state was possible, the experimental results were adjusted accordingly. Afterwards all results were included in the framework of the atomic-mass evaluation and thus linked and compared with other experimental data. In the case of a potential isomeric mixture as for 115,117,119 Ag and 123 Cd, where no assignment to either the ground state or the excited state was possible, the experimental results were adjusted accordingly. Afterwards all results were included in the framework of the atomic-mass evaluation and thus linked and compared with other experimental data. In the case of the neutron-deficient Cd nuclides a conflict between the mass values obtained in the present work and those published by the JYFLTRAP group [EEH + ] could be solved by performing an atomic-mass evaluation. Thus, it was revealed that reason for the conflict was a different value of the JYFLTRAP reference mass 96 Mo. Furthermore, a reduction of the mass uncertainty and a slight increase of the mass of 100 In were obtained. These mass measurements are an important step towards an understanding of the physics of the rp process that will enable a more reliable determination of

  14. How to measure wisdom: content, reliability, and validity of five measures

    Science.gov (United States)

    Glück, Judith; König, Susanne; Naschenweng, Katja; Redzanowski, Uwe; Dorner, Lara; Straßer, Irene; Wiedermann, Wolfgang

    2013-01-01

    Wisdom is a field of growing interest both inside and outside academic psychology, and researchers are increasingly interested in using measures of wisdom in their work. However, wisdom is a highly complex construct, and its various operationalizations are based on quite different definitions. Which measure a researcher chooses for a particular research project may have a strong influence on the results. This study compares four well-established measures of wisdom—the Self-Assessed Wisdom Scale (Webster, 2003, 2007), the Three-Dimensional Wisdom Scale (Ardelt, 2003), the Adult Self-Transcendence Inventory (Levenson et al., 2005), and the Berlin Wisdom Paradigm (Baltes and Smith, 1990; Baltes and Staudinger, 2000)—with respect to content, reliability, factorial structure, and construct validity (relationships to wisdom nomination, interview-based wisdom ratings, and correlates of wisdom). The sample consisted of 47 wisdom nominees and 123 control participants. While none of the measures performed “better” than the others by absolute standards, recommendations are given for researchers to select the most suitable measure for their substantive interests. In addition, a “Brief Wisdom Screening Scale” is introduced that contains those 20 items from the three self-report scales that were most highly correlated with the common factor across the scales. PMID:23874310

  15. Reliability and Measurement Error of Tensiomyography to Assess Mechanical Muscle Function: A Systematic Review.

    Science.gov (United States)

    Martín-Rodríguez, Saúl; Loturco, Irineu; Hunter, Angus M; Rodríguez-Ruiz, David; Munguia-Izquierdo, Diego

    2017-12-01

    Martín-Rodríguez, S, Loturco, I, Hunter, AM, Rodríguez-Ruiz, D, and Munguia-Izquierdo, D. Reliability and measurement error of tensiomyography to assess mechanical muscle function: A systematic review. J Strength Cond Res 31(12): 3524-3536, 2017-Interest in studying mechanical skeletal muscle function through tensiomyography (TMG) has increased in recent years. This systematic review aimed to (a) report the reliability and measurement error of all TMG parameters (i.e., maximum radial displacement of the muscle belly [Dm], contraction time [Tc], delay time [Td], half-relaxation time [½ Tr], and sustained contraction time [Ts]) and (b) to provide critical reflection on how to perform accurate and appropriate measurements for informing clinicians, exercise professionals, and researchers. A comprehensive literature search was performed of the Pubmed, Scopus, Science Direct, and Cochrane databases up to July 2017. Eight studies were included in this systematic review. Meta-analysis could not be performed because of the low quality of the evidence of some studies evaluated. Overall, the review of the 9 studies involving 158 participants revealed high relative reliability (intraclass correlation coefficient [ICC]) for Dm (0.91-0.99); moderate-to-high ICC for Ts (0.80-0.96), Tc (0.70-0.98), and ½ Tr (0.77-0.93); and low-to-high ICC for Td (0.60-0.98), independently of the evaluated muscles. In addition, absolute reliability (coefficient of variation [CV]) was low for all TMG parameters except for ½ Tr (CV = >20%), whereas measurement error indexes were high for this parameter. In conclusion, this study indicates that 3 of the TMG parameters (Dm, Td, and Tc) are highly reliable, whereas ½ Tr demonstrate insufficient reliability, and thus should not be used in future studies.

  16. The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals

    Energy Technology Data Exchange (ETDEWEB)

    Fuller, Joel T.; Buckley, Jonathan D.; Tsiros, Margarita D.; Thewlis, Dominic [University of South Australia, Alliance for Research in Exercise, Nutrition and Activity (ARENA), Sansom Institute for Health Research, GPO Box 2471, Adelaide, South Australia (Australia); Archer, Jane [University of South Australia, Medical Radiation, School of Health Sciences, Adelaide (Australia)

    2016-01-15

    To investigate the reliability of a simple, efficient technique for measuring bone mineral density (BMD) in the metatarsals using dual-energy X-ray absorptiometry (DXA). BMD of the right foot of 32 trained male distance runners was measured using a DXA scanner with the foot in the plantar position. Separate regions of interest (ROI) were used to assess the BMD of each metatarsal shaft (1st-5th) for each participant. ROI analysis was repeated by the same investigator to determine within-scan intra-rater reliability and by a different investigator to determine within-scan inter-rater reliability. Repeat DXA scans were undertaken for ten participants to assess between-scan intra-rater reliability. Assessment of BMD was consistently most reliable for the first metatarsal across all domains of reliability assessed (intra-class correlation coefficient [ICC] ≥0.97; coefficient of variation [CV] ≤1.5 %; limits of agreement [LOA] ≤4.2 %). Reasonable levels of intra-rater reliability were also achieved for the second and fifth metatarsals (ICC ≥0.90; CV ≤4.2 %; LOA ≤11.9 %). Poorer levels of reliability were demonstrated for the third (ICC ≥0.64; CV ≤8.2 %; LOA ≤23.6 %) and fourth metatarsals (ICC ≥0.67; CV ≤9.6 %; LOA ≤27.5 %). BMD was greatest in the first and second metatarsals (P < 0.01). Reliable measurements of BMD were achieved for the first, second and fifth metatarsals. (orig.)

  17. The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals

    International Nuclear Information System (INIS)

    Fuller, Joel T.; Buckley, Jonathan D.; Tsiros, Margarita D.; Thewlis, Dominic; Archer, Jane

    2016-01-01

    To investigate the reliability of a simple, efficient technique for measuring bone mineral density (BMD) in the metatarsals using dual-energy X-ray absorptiometry (DXA). BMD of the right foot of 32 trained male distance runners was measured using a DXA scanner with the foot in the plantar position. Separate regions of interest (ROI) were used to assess the BMD of each metatarsal shaft (1st-5th) for each participant. ROI analysis was repeated by the same investigator to determine within-scan intra-rater reliability and by a different investigator to determine within-scan inter-rater reliability. Repeat DXA scans were undertaken for ten participants to assess between-scan intra-rater reliability. Assessment of BMD was consistently most reliable for the first metatarsal across all domains of reliability assessed (intra-class correlation coefficient [ICC] ≥0.97; coefficient of variation [CV] ≤1.5 %; limits of agreement [LOA] ≤4.2 %). Reasonable levels of intra-rater reliability were also achieved for the second and fifth metatarsals (ICC ≥0.90; CV ≤4.2 %; LOA ≤11.9 %). Poorer levels of reliability were demonstrated for the third (ICC ≥0.64; CV ≤8.2 %; LOA ≤23.6 %) and fourth metatarsals (ICC ≥0.67; CV ≤9.6 %; LOA ≤27.5 %). BMD was greatest in the first and second metatarsals (P < 0.01). Reliable measurements of BMD were achieved for the first, second and fifth metatarsals. (orig.)

  18. The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals.

    Science.gov (United States)

    Fuller, Joel T; Archer, Jane; Buckley, Jonathan D; Tsiros, Margarita D; Thewlis, Dominic

    2016-01-01

    To investigate the reliability of a simple, efficient technique for measuring bone mineral density (BMD) in the metatarsals using dual-energy X-ray absorptiometry (DXA). BMD of the right foot of 32 trained male distance runners was measured using a DXA scanner with the foot in the plantar position. Separate regions of interest (ROI) were used to assess the BMD of each metatarsal shaft (1st-5th) for each participant. ROI analysis was repeated by the same investigator to determine within-scan intra-rater reliability and by a different investigator to determine within-scan inter-rater reliability. Repeat DXA scans were undertaken for ten participants to assess between-scan intra-rater reliability. Assessment of BMD was consistently most reliable for the first metatarsal across all domains of reliability assessed (intra-class correlation coefficient [ICC] ≥0.97; coefficient of variation [CV] ≤1.5%; limits of agreement [LOA] ≤4.2%). Reasonable levels of intra-rater reliability were also achieved for the second and fifth metatarsals (ICC ≥0.90; CV ≤4.2%; LOA ≤11.9%). Poorer levels of reliability were demonstrated for the third (ICC ≥0.64; CV ≤8.2%; LOA ≤23.6%) and fourth metatarsals (ICC ≥0.67; CV ≤9.6%; LOA ≤27.5%). BMD was greatest in the first and second metatarsals (P Reliable measurements of BMD were achieved for the first, second and fifth metatarsals.

  19. Research on reliability measures of the main transformer and GIS equipment manufacturing process

    International Nuclear Information System (INIS)

    Wu Honglong

    2014-01-01

    Based on the accidents of the main transformer GIS equipment and the accidents of the high voltage switch equipment, combined with the main transformer switch equipment maintenance experience and electrical theory, the reliability measures of the main transformer GIS equipment during manufacturing stage are studied and improved. Six successful reliability measures are identified: 1) design properly and check the ability of transformer for anti short circuit; 2) choose mature and reliable main transformer HV bushing; 3) choose GIS switch operation mechanism of high quality and reliability; 4) ensure that the insulation margin through tests piece by piece on withstand voltage and partial discharge of the GIS equipment insulation; 5) take test measures such as GIS conductor, shell polishing witness process and full form lightning impulse, to find out and eliminate the defects of abnormal electric field distribution; 6) Anti VFTO design for the main transformer connected with GIS with the voltage of 500 kV should be considered, and its anti VFTO ability to meet the safe operation under VFTO requirements should be checked. This paper proposed 2 new measures: 1) the main transformer insulation material quality standard is determined not only by its high dielectric strength, but more importantly by the homogeneous dielectric electric strength. Insulating Materials with a high and also uniform dielectric strength should be chosen. 2) During the silver-coating stage of the GIS equipment conductor, QC group activities should be organized to ensure that the plating layer quality, and the current lap surface DC resistance measurements should be supervised and witnessed to ensure the quality of the conductor contact surface. These measures are verified in Fuqing project of GIS main transformer equipment manufacturing process, and their effectiveness is proven. (author)

  20. arXiv Top Quark Mass Measurements at the LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00220136

    2016-01-01

    The top quark mass ($m_{top}$) is a fundamental parameter of the Standard Model of Particle Physics (SM). As the heaviest of all SM particles with a mass close to the electroweak symmetry-breaking scale, the top quark plays a pivotal role in the theory of elementary particles. The exact value of the top quark mass has implications on a number of theoretical predictions, which motivates the need for precision measurements of $m_{top}$. This document highlights a number of such measurements carried out by the ATLAS and CMS collaborations based on the combined LHC Run 1 datasets at centre-of-mass energies of $\\sqrt{s}=7$ and $8$ TeV. A wide range of analysis strategies are employed for a number of final-state signatures. Measurements of both the top quark pole mass as well as the value of $m_{top}$ as defined by the Monte Carlo generator in simulated signal samples are discussed.

  1. Measuring Intermediate-Mass Black-Hole Binaries with Advanced Gravitational Wave Detectors.

    Science.gov (United States)

    Veitch, John; Pürrer, Michael; Mandel, Ilya

    2015-10-02

    We perform a systematic study to explore the accuracy with which the parameters of intermediate-mass black-hole binary systems can be measured from their gravitational wave (GW) signatures using second-generation GW detectors. We make use of the most recent reduced-order models containing inspiral, merger, and ringdown signals of aligned-spin effective-one-body waveforms to significantly speed up the calculations. We explore the phenomenology of the measurement accuracies for binaries with total masses between 50M(⊙) and 500M(⊙) and mass ratios between 0.1 and 1. We find that (i) at total masses below ∼200M(⊙), where the signal-to-noise ratio is dominated by the inspiral portion of the signal, the chirp mass parameter can be accurately measured; (ii) at higher masses, the information content is dominated by the ringdown, and total mass is measured more accurately; (iii) the mass of the lower-mass companion is poorly estimated, especially at high total mass and more extreme mass ratios; and (iv) spin cannot be accurately measured for our injection set with nonspinning components. Most importantly, we find that for binaries with nonspinning components at all values of the mass ratio in the considered range and at a network signal-to-noise ratio of 15, analyzed with spin-aligned templates, the presence of an intermediate-mass black hole with mass >100M(⊙) can be confirmed with 95% confidence in any binary that includes a component with a mass of 130M(⊙) or greater.

  2. Reliability and Validity of Selected PROMIS Measures in People with Rheumatoid Arthritis.

    Directory of Open Access Journals (Sweden)

    Susan J Bartlett

    Full Text Available To evaluate the reliability and validity of 11 PROMIS measures to assess symptoms and impacts identified as important by people with rheumatoid arthritis (RA.Consecutive patients (N = 177 in an observational study completed PROMIS computer adapted tests (CATs and a short form (SF assessing pain, fatigue, physical function, mood, sleep, and participation. We assessed test-test reliability and internal consistency using correlation and Cronbach's alpha. We assessed convergent validity by examining Pearson correlations between PROMIS measures and existing measures of similar domains and known groups validity by comparing scores across disease activity levels using ANOVA.Participants were mostly female (82% and white (83% with mean (SD age of 56 (13 years; 24% had ≤ high school, 29% had RA ≤ 5 years with 13% ≤ 2 years, and 22% were disabled. PROMIS Physical Function, Pain Interference and Fatigue instruments correlated moderately to strongly (rho's ≥ 0.68 with corresponding PROs. Test-retest reliability ranged from .725-.883, and Cronbach's alpha from .906-.991. A dose-response relationship with disease activity was evident in Physical Function with similar trends in other scales except Anger.These data provide preliminary evidence of reliability and construct validity of PROMIS CATs to assess RA symptoms and impacts, and feasibility of use in clinical care. PROMIS instruments captured the experiences of RA patients across the broad continuum of RA symptoms and function, especially at low disease activity levels. Future research is needed to evaluate performance in relevant subgroups, assess responsiveness and identify clinically meaningful changes.

  3. Assessment of intra-interobserver reliability of the sonographic optic nerve sheath diameter measurement

    Directory of Open Access Journals (Sweden)

    Tuba Cimilli Ozturk

    2015-08-01

    Full Text Available Diagnosis and measuring the level of increase in intracranial pressure (ICP is critical, especially for the management of trauma patients in the emergency department and intensive care unit. However, measurements are operator-dependent as in all of the sonographic diagnoses. The aim of this study is to assess the operator variations in the measurement of optic nerve sheath diameter (ONSD. There were four emergency medicine specialists involved in the study. Each had at least 1 year of experience of ultrasound scans and performed at least 25 prior ocular scans examining the ONSD. Two measurements were made 1 week apart from both axial and longitudinal planes. Sixty healthy adults were involved in the study and every investigator obtained four measurements from each. Intra-interobserver reliabilities were tested. The investigators performed 60 ocular ultrasounds on individual healthy adults and obtained two measurements in axial and longitudinal planes 1 week apart. Therefore, 960 measurements were analyzed. The levels of compatibilities for most of the measurements were found at acceptable levels statistically. However, it is not possible to say that there was a perfect compatibility among the sonographers according to the previously conducted reliability studies of ultrasound measurements. According to our results, it is hard to say that sonographic measurement of the ONSD is a highly reliable method both in longitudinal and transverse planes.

  4. Recent CMS measurements of the top quark mass

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    The top quark is the heaviest known particle, and the only colored one that decays before hadronization. Its mass is a fundamental parameter of the standard model. Precision measurements of the top-quark mass can be used to test the self-consistency of the standard model and, at the same time, to study effects of non-perturbative QCD. CMS recently completed the set of standard top quark mass measurements at 8 TeV in all three decay channels, reaching sub-GeV uncertainty for the first time in a single analysis and combining to the most precise single-experiment measurement. With the steady increase in experimental precision comes a theoretical challenge of interpreting the results and the motivation of using alternative methods. In this talk we present the CMS set of analyses using the 8 TeV dataset, both with conventional methods and non-standard techniques targeting different definitions of the top quark mass. Furthermore we give an outlook at expected future improvements in both standard and alternative app...

  5. Zero G Mass Measurement Device (ZGMMD), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Zero G Mass Measurement Device (ZGMMD) will provide the ability to quantify the mass of objects up to 2,000 grams, including live animal specimens in a zero G...

  6. Test-Retest Reliability of Isokinetic Knee Strength Measurements in Children Aged 8 to 10 Years.

    Science.gov (United States)

    Fagher, Kristina; Fritzson, Annelie; Drake, Anna Maria

    Isokinetic dynamometry is a useful tool to objectively assess muscle strength of children and adults in athletic and rehabilitative settings. This study examined test-retest reliability of isokinetic knee strength measurements in children aged 8 to 10 years and defined limits for the minimum difference (MD) in strength that indicates a clinically important change. Isokinetic knee strength measurements (using the Biodex System 4) in children will provide reliable results. Descriptive laboratory study. In 22 healthy children, 5 maximal concentric (CON) knee extensor (KE) and knee flexor (KF) contractions at 2 angular velocities (60 deg/s and 180 deg/s) and 5 maximal eccentric (ECC) KE/KF contractions at 60 deg/s were assessed 7 days apart. The intraclass correlation coefficient (ICC 2.1 ) was used to examine relative reliability, and the MD was calculated on the basis of standard error of measurement. ICCs for CON KE/KF peak torque measurements were fair to excellent (range, 0.49-0.81). The MD% values for CON KE and KF ranged from 31% to 37% at 60 deg/s and from 34% to 39% at 180 deg/s. ICCs in the ECC mode were good (range, 0.60-0.70), but associated MD% values were high (>50%). There was no systematic error for CON KE/KF and ECC KE strength measurements at 60 deg/s, but systematic error was found for all other measurements. The dynamometer provides a reliable analysis of isokinetic CON knee strength measurements at 60 deg/s in children aged 8 to 10 years. Measurements at 180 deg/s and in the ECC mode were not reliable, indicating a need for more familiarization prior to testing. The MD values may help clinicians to determine whether a change in knee strength is due to error or intervention.

  7. A Precise Measurement of the W Boson Mass with CDF

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    The W boson mass measurement probes quantum corrections to the W propagator, such as those arising from supersymmetric particles or Higgs bosons. The new measurement from CDF is more precise than the previous world average, providing a stringent constraint on the mass of the Higgs boson in the context of the Standard Model. I describe this measurement, performed with 2.2/fb of data using 1.1 million candidates in the electron and muon decay channels, with three kinematic fits in each channel. The measurement uses in-situ calibrations from cosmic rays, J/psi and Upsilon data, and W- and Z-boson decays, with multiple cross-checks including independent determinations of the Z boson mass in both channels. The W-boson mass is measured to be 80387 +- 19 MeV/c^2.

  8. Reliability of Pressure Ulcer Rates: How Precisely Can We Differentiate Among Hospital Units, and Does the Standard Signal‐Noise Reliability Measure Reflect This Precision?

    Science.gov (United States)

    Cramer, Emily

    2016-01-01

    Abstract Hospital performance reports often include rankings of unit pressure ulcer rates. Differentiating among units on the basis of quality requires reliable measurement. Our objectives were to describe and apply methods for assessing reliability of hospital‐acquired pressure ulcer rates and evaluate a standard signal‐noise reliability measure as an indicator of precision of differentiation among units. Quarterly pressure ulcer data from 8,199 critical care, step‐down, medical, surgical, and medical‐surgical nursing units from 1,299 US hospitals were analyzed. Using beta‐binomial models, we estimated between‐unit variability (signal) and within‐unit variability (noise) in annual unit pressure ulcer rates. Signal‐noise reliability was computed as the ratio of between‐unit variability to the total of between‐ and within‐unit variability. To assess precision of differentiation among units based on ranked pressure ulcer rates, we simulated data to estimate the probabilities of a unit's observed pressure ulcer rate rank in a given sample falling within five and ten percentiles of its true rank, and the probabilities of units with ulcer rates in the highest quartile and highest decile being identified as such. We assessed the signal‐noise measure as an indicator of differentiation precision by computing its correlations with these probabilities. Pressure ulcer rates based on a single year of quarterly or weekly prevalence surveys were too susceptible to noise to allow for precise differentiation among units, and signal‐noise reliability was a poor indicator of precision of differentiation. To ensure precise differentiation on the basis of true differences, alternative methods of assessing reliability should be applied to measures purported to differentiate among providers or units based on quality. © 2016 The Authors. Research in Nursing & Health published by Wiley Periodicals, Inc. PMID:27223598

  9. Mass-spectrometric measurements for nuclear safeguards

    International Nuclear Information System (INIS)

    Carter, J.A.; Smith, D.H.; Walker, R.L.

    1982-01-01

    The need of an on-site inspection device to provide isotopic ratio measurements led to the development of a quadrupole mass spectrometer mounted in a van. This mobile laboratory has the ability, through the use of the resin bead technique, to acquire, prepare, and analyze samples of interest to nuclear safeguards. Precision of the measurements is about 1 to 2%

  10. Mass measurement of 80Y by β-γ coincidence spectroscopy

    International Nuclear Information System (INIS)

    Barton, C.J.; Caprio, M.A.; Beausang, C.W.; Casten, R.F.; Cooper, J.R.; Kruecken, R.; Novak, J.R.; Pietralla, N.; Brenner, D.S.; Zamfir, N.V.; Aprahamian, A.; Wiescher, M.C.; Shawcross, M.; Teymurazyan, A.; Berant, Z.; Wolf, A.; Gill, R.L.

    2003-01-01

    The Q EC value of 80 Y has been measured by β-γ coincidence spectroscopy to be ≥8929(83) keV. Combining this result with the adopted mass excess of the daughter 80 Sr gives a mass excess for 80 Y of ≥-61 376(83) keV. Results are compared with other measurements, with Audi-Wapstra systematics, and with predictions of mass formulas. Implications of this measurement are considered for the rp process

  11. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  12. Comparison of muscle/lean mass measurement methods: correlation with functional and biochemical testing.

    Science.gov (United States)

    Buehring, B; Siglinsky, E; Krueger, D; Evans, W; Hellerstein, M; Yamada, Y; Binkley, N

    2018-03-01

    DXA-measured lean mass is often used to assess muscle mass but has limitations. Thus, we compared DXA lean mass with two novel methods-bioelectric impedance spectroscopy and creatine (methyl-d3) dilution. The examined methodologies did not measure lean mass similarly and the correlation with muscle biomarkers/function varied. Muscle function tests predict adverse health outcomes better than lean mass measurement. This may reflect limitations of current mass measurement methods. Newer approaches, e.g., bioelectric impedance spectroscopy (BIS) and creatine (methyl-d3) dilution (D3-C), may more accurately assess muscle mass. We hypothesized that BIS and D3-C measured muscle mass would better correlate with function and bone/muscle biomarkers than DXA measured lean mass. Evaluations of muscle/lean mass, function, and serum biomarkers were obtained in older community-dwelling adults. Mass was assessed by DXA, BIS, and orally administered D3-C. Grip strength, timed up and go, and jump power were examined. Potential muscle/bone serum biomarkers were measured. Mass measurements were compared with functional and serum data using regression analyses; differences between techniques were determined by paired t tests. Mean (SD) age of the 112 (89F/23M) participants was 80.6 (6.0) years. The lean/muscle mass assessments were correlated (.57-.88) but differed (p Lean mass measures were unrelated to the serum biomarkers measured. These three methodologies do not similarly measure muscle/lean mass and should not be viewed as being equivalent. Functional tests assessing maximal muscle strength/power (grip strength and jump power) correlated with all mass measures whereas gait speed was not. None of the selected serum measures correlated with mass. Efforts to optimize muscle mass assessment and identify their relationships with health outcomes are needed.

  13. Comparisons between different techniques for measuring mass segregation

    Science.gov (United States)

    Parker, Richard J.; Goodwin, Simon P.

    2015-06-01

    We examine the performance of four different methods which are used to measure mass segregation in star-forming regions: the radial variation of the mass function {M}_MF; the minimum spanning tree-based ΛMSR method; the local surface density ΣLDR method; and the ΩGSR technique, which isolates groups of stars and determines whether the most massive star in each group is more centrally concentrated than the average star. All four methods have been proposed in the literature as techniques for quantifying mass segregation, yet they routinely produce contradictory results as they do not all measure the same thing. We apply each method to synthetic star-forming regions to determine when and why they have shortcomings. When a star-forming region is smooth and centrally concentrated, all four methods correctly identify mass segregation when it is present. However, if the region is spatially substructured, the ΩGSR method fails because it arbitrarily defines groups in the hierarchical distribution, and usually discards positional information for many of the most massive stars in the region. We also show that the ΛMSR and ΣLDR methods can sometimes produce apparently contradictory results, because they use different definitions of mass segregation. We conclude that only ΛMSR measures mass segregation in the classical sense (without the need for defining the centre of the region), although ΣLDR does place limits on the amount of previous dynamical evolution in a star-forming region.

  14. Direct mass measurements of neutron-deficient xenon isotopes using the ISOLTRAP mass spectrometer

    CERN Document Server

    Dilling, J; Beck, D; Bollen, G; Herfurth, F; Kellerbauer, A G; Kluge, H J; Moore, R B; Scheidenberger, C; Schwarz, S; Sikler, G

    2004-01-01

    The masses of the noble-gas Xe isotopes with 114 $\\leq$ A $\\leq$ 123 have been directly measured for the first time. The experiments were carried out with the ISOLTRAP triple trap spectrometer at the online mass separator ISOLDE/CERN. A mass resolving power of the Penning trap spectrometer of $m/\\Delta m$ of close to a million was chosen resulting in an accuracy of $\\delta m \\leq 13$ keV for all investigated isotopes. Conflicts with existing, indirectly obtained, mass data by several standard deviations were found and are discussed. An atomic mass evaluation has been performed and the results are compared to information from laser spectroscopy experiments and to recent calculations employing an interacting boson model.

  15. Significancy in atomic mass measurements and the topography of the mass-surface

    International Nuclear Information System (INIS)

    Audi, G.

    1991-01-01

    It is discussed how to explore new regions of the chart of the nuclides through masses, and what has to be understood under significant mass measurements. In the exploratory phase of a new region of the chart, a result with almost any accuracy is appropriate. The higher the accuracy is, the better the possibility is to see finer structures. (G.P.) 24 refs.; 10 figs

  16. Measuring the airway in 3 dimensions: a reliability and accuracy study.

    Science.gov (United States)

    El, Hakan; Palomo, Juan Martin

    2010-04-01

    The aim of the study was to compare the reliability and accuracy of 3 commercially available digital imaging and communications in medicine (DICOM) viewers for measuring upper airway volumes. Thirty cone-beam computed tomography scans were randomly selected, and the upper airway volumes were calculated for both oropharynx and nasal passage. Dolphin3D (version 11, Dolphin Imaging & Management Solutions, Chatsworth, Calif), InVivoDental (version 4.0.70, Anatomage, San Jose, Calif), and OnDemand3D (version 1.0.1.8407, CyberMed, Seoul, Korea) were compared with a previously tested manual segmentation program called OrthoSegment (OS) (developed at the Department of Orthodontics at Case Western Reserve University, Cleveland, Ohio). The measurements were repeated after 2 weeks, and the ICC was used for the reliability tests. All commercially available programs were compared with the OS program by using regression analysis. The Pearson correlation was used to evaluate the correlation between the OS and the automatic segmentation programs. The reliability was high for all programs. The highest correlation found was between the OS and Dolphin3D for the oropharynx, and between the OS and InVivoDental for nasal passage volume. A high correlation was found for all programs, but the results also showed statistically significant differences compared with the OS program. The programs also had inconsistencies among themselves. The 3 commercially available DICOM viewers are highly reliable in their airway volume calculations and showed high correlation of results but poor accuracy, suggesting systematic errors. Copyright 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  17. Measurement of the W boson mass

    International Nuclear Information System (INIS)

    Abe, F.; Albrow, M.G.; Amendolia, S.R.; Amidei, D.; Antos, J.; Anway-Wiese, C.; Apollinari, G.; Areti, H.; Atac, M.; Auchincloss, P.; Azfar, F.; Azzi, P.; Bacchetta, N.; Badgett, W.; Bailey, M.W.; Bao, J.; de Barbaro, P.; Barbaro-Galtieri, A.; Barnes, V.E.; Barnett, B.A.; Bartalini, P.; Bauer, G.; Baumann, T.; Bedeschi, F.; Behrends, S.; Belforte, S.; Bellettini, G.; Bellinger, J.; Benjamin, D.; Benlloch, J.; Bensinger, J.; Benton, D.; Beretvas, A.; Berge, J.P.; Bertolucci, S.; Bhatti, A.; Biery, K.; Binkley, M.; Bird, F.; Bisello, D.; Blair, R.E.; Blocker, C.; Bodek, A.; Bokhari, W.; Bolognesi, V.; Bortoletto, D.; Boswell, C.; Boulos, T.; Brandenburg, G.; Bromberg, C.; Buckley-Geer, E.; Budd, H.S.; Burkett, K.; Busetto, G.; Byon-Wagner, A.; Byrum, K.L.; Cammerata, J.; Campagnari, C.; Campbell, M.; Caner, A.; Carithers, W.; Carlsmith, D.; Castro, A.; Cen, Y.; Cervelli, F.; Chao, H.Y.; Chapman, J.; Cheng, M.; Chiarelli, G.; Chikamatsu, T.; Chiou, C.N.; Christofek, L.; Cihangir, S.; Clark, A.G.; Cobal, M.; Contreras, M.; Conway, J.; Cooper, J.; Cordelli, M.; Couyoumtzelis, C.; Crane, D.; Cunningham, J.D.; Daniels, T.; DeJongh, F.; Delchamps, S.; Dell'Agnello, S.; Dell'Orso, M.; Demortier, L.; Denby, B.; Deninno, M.; Derwent, P.F.; Devlin, T.; Dickson, M.; Dittmann, J.R.; Donati, S.; Drucker, R.B.; Dunn, A.; Einsweiler, K.; Elias, J.E.; Ely, R.; Engels, E. Jr.; Eno, S.; Errede, D.; Errede, S.; Fan, Q.; Farhat, B.; Fiori, I.; Flaugher, B.; Foster, G.W.; Franklin, M.; Frautschi, M.; Freeman, J.; Friedman, J.; Frisch, H.; Fry, A.; Fuess, T.A.; Fukui, Y.; Funaki, S.; Gagliardi, G.; Galeotti, S.; Gallinaro, M.; Garfinkel, A.F.; Geer, S.; Gerdes, D.W.; Giannetti, P.; Giokaris, N.; Giromini, P.; Gladney, L.; Glenzinski, D.; Gold, M.; Gonzalez, J.; Gordon, A.; Goshaw, A.T.; Goulianos, K.; Grassmann, H.; Grewal, A.; Groer, L.; Grosso-Pilcher, C.; Haber, C.; Hahn, S.R.; Hamilton, R.; Handler, R.; Hans, R.M.; Hara, K.; Harral, B.; Harris, R.M.; Hauger, S.A.

    1995-01-01

    We present a measurement of the mass of the W boson using data collected with the Collider Detector at Fermilab during the 1992--93 collider run at the Fermilab Tevatron. A fit to the transverse mass spectrum of a sample of 3268 W→μν events recorded in an integrated luminosity of 19.7pb -1 gives a mass M W μ =80.310±0.205(stat)±0.130(syst)GeV/c 2 . A fit to 5718 W→eν events recorded in 18.2 pb --1 gives M e W =80.490±0.145(stat)±0.175(syst)GeV/c 2 . Combining these results, accounting for correlated uncertainties, yields M W =80.410±0.180GeV/c 2

  18. Reliability of agriculture universal joint shafts based on temperature measuring in universal joint bearing assemblies

    Directory of Open Access Journals (Sweden)

    Аleksandar Asonja

    2015-03-01

    Full Text Available This paper presents a research into reliability calculations of agriculture double universal joint shafts based on temperature measuring in cardan-type universal joint bearing assemblies. Special laboratory equipment was developed for this research which is presented in the paper. The objective of this research was to test the real life span of universal joint shafts in the laboratory and in field, to obtain the results which can be used to improve the reliability of universal joint shafts. If the presented research were used along with maintenance measures recommended in the paper and with proper use, the level of reliability of the shafts would be 2.1 times higher. The presented results of the research showed that needle bearings, i.e. bearing assemblies of the joints, are the most critical elements on universal joint shafts and are possible causes of their lower reliability. The second universal joint is the part with the lowest reliability in the observed technical system.

  19. Harmonization process and reliability assessment of anthropometric measurements in the elderly EXERNET multi-centre study.

    Directory of Open Access Journals (Sweden)

    Alba Gómez-Cabello

    Full Text Available BACKGROUND: The elderly EXERNET multi-centre study aims to collect normative anthropometric data for old functionally independent adults living in Spain. PURPOSE: To describe the standardization process and reliability of the anthropometric measurements carried out in the pilot study and during the final workshop, examining both intra- and inter-rater errors for measurements. MATERIALS AND METHODS: A total of 98 elderly from five different regions participated in the intra-rater error assessment, and 10 different seniors living in the city of Toledo (Spain participated in the inter-rater assessment. We examined both intra- and inter-rater errors for heights and circumferences. RESULTS: For height, intra-rater technical errors of measurement (TEMs were smaller than 0.25 cm. For circumferences and knee height, TEMs were smaller than 1 cm, except for waist circumference in the city of Cáceres. Reliability for heights and circumferences was greater than 98% in all cases. Inter-rater TEMs were 0.61 cm for height, 0.75 cm for knee-height and ranged between 2.70 and 3.09 cm for the circumferences measured. Inter-rater reliabilities for anthropometric measurements were always higher than 90%. CONCLUSION: The harmonization process, including the workshop and pilot study, guarantee the quality of the anthropometric measurements in the elderly EXERNET multi-centre study. High reliability and low TEM may be expected when assessing anthropometry in elderly population.

  20. Top mass measurement at CDF

    International Nuclear Information System (INIS)

    Rolli, S.

    1996-06-01

    We present the measurement of the top quark mass using L = 110 pb -1 data sample of pp collisions at √s = 1.8 TeV collected with the Collider Detector at Fermilab (CDF). We show the results for the different channels and discuss with some emphasis the determination of the systematic uncertainties. 7 refs., 10 figs., 5 tabs

  1. Measurement of the W boson mass in the Delphi experiment

    International Nuclear Information System (INIS)

    Simard, L.

    2000-01-01

    After the Z 0 study during the first phase of LEP, the properties of the W boson, in particular its mass, are precisely measured at LEP2. After the implications of that measurement on the Higgs mass being explained, the analysis of the WW semileptonic events, where the two W decay into two quarks, a charged lepton and a neutrino, is described. It was carried out with the data sample collected at DELPHI in 1997 and 1998, corresponding to an integrated luminosity of 211.1 pb -1 . The measurement, based upon a likelihood fit applied both to simulation and data requires that all variables of simulation reproduce well the data. Comparisons between Monte Carlo and data are set out, as well as the selection of WW events and the kinematical fit used to improve the mass resolution. The method used to estimate the systematic errors on the measurement and the result of the measurement are presented. When combining these measurements with the measurements done in the hadronic channel, the mass and the width are measured. (author)

  2. Validity and Reliability of Dynamic Visual Acuity (DVA) Measurement During Walking

    Science.gov (United States)

    Deshpande, Nandini; Peters, Brian T.; Bloomberg, Jacob J.

    2014-01-01

    DVA is primarily subserved by the vestibulo-ocular reflex mechanism. Individuals with vestibular hypofunction commonly experience highly debilitating illusory movement or blurring of visual images during daily activities possibly, due to impaired DVA. Even without pathologies, gradual age-related morphological deterioration is evident in all components of the vestibular system. We examined the construct validity to detect age-related differences and test-retest reliability of DVA measurements performed during walking. METHODS: Healthy adults were recruited into 3 groups: 1. young (20-39years, n=18), 2. middle-aged (40-59years, n=14), and 3. older adults (60-80years, n=15). Randomly selected seven participants from each group (n=21) participated in retesting. Participants were excluded if they had a history of vestibular or neuromuscular pathologies, dizziness/vertigo or >1 falls in the past year. Older persons with MMSE scores reliability. RESULTS: The three age groups were not different in their height, weight and normal walking speed (p>0.05). The post hoc analyses for DVA measurements demonstrated that each group was significantly different from the other two groups for Near as well as FarDVA (preliability. FarDVA at 0.8 m/s and 1.0 m/s demonstrated good test-retest reliability (ICCs 0.71 and 0.77, respectively).

  3. Reliability and responsiveness of a goniometric device for measuring the range of motion in the dart-throwing motion plane.

    Science.gov (United States)

    Kasubuchi, Kenji; Dohi, Yoshihiro; Fujita, Hiroyuki; Fukumoto, Takahiko

    2018-02-26

    Dart-throwing motion (DTM) is an important component of wrist function and, consequently, has the potential to become an evaluation tool in rehabilitation. However, no measurement method is currently available to reliably measure range of motion (ROM) of the wrist in the DTM plane. To determine the reliability and responsiveness of a goniometric device to measure wrist ROM in the DTM plane. ROM of the wrist in the DTM plane was measured in 70 healthy participants. The intra-class correlation coefficient (ICC) was used to evaluate the relative reliability of measurement, and a Bland-Altman analysis conducted to establish its absolute reliability, including the 95% limits of agreement (95% LOA). The standard error of the measurement (SEM) and minimal detectable change at the 95% confidence level (MDC 95 ) were calculated as measures of responsiveness. The intra-rater ICC was 0.87, and an inter-rater ICC of 0.71. There was no evidence of a fixed or proportional bias. For intra- and inter-rater reliability, 95% LOA ranged from -13.83 to 11.12 and from -17.75 to 16.19, respectively. The SEM and MDC 95 were 4.5° and 12.4°, respectively, for intra-rater reliability, and 6.0° and 16.6°, respectively, for inter-rater reliability. The ROM of the wrist in the DTM plane was measured with fair-to-good reliability and responsiveness and, therefore, has the potential to become an evaluation tool for rehabilitation.

  4. Reliability of internal oblique elbow radiographs for measuring displacement of medial epicondyle humerus fractures: a cadaveric study.

    Science.gov (United States)

    Gottschalk, Hilton P; Bastrom, Tracey P; Edmonds, Eric W

    2013-01-01

    Standard elbow radiographs (AP and lateral views) are not accurate enough to measure true displacement of medial epicondyle fractures of the humerus. The amount of perceived displacement has been used to determine treatment options. This study assesses the utility of internal oblique radiographs for measurement of true displacement in these fractures. A medial epicondyle fracture was created in a cadaveric specimen. Displacement of the fragment (mm) was set at 5, 10, and 15 in line with the vector of the flexor pronator mass. The fragment was sutured temporarily in place. Radiographs were obtained at 0 (AP), 15, 30, 45, 60, 75, and 90 degrees (lateral) of internal rotation, with the elbow in set positions of flexion. This was done with and without radio-opaque markers placed on the fragment and fracture bed. The 45 and 60 degrees internal oblique radiographs were then presented to 5 separate reviewers (of different levels of training) to evaluate intraobserver and interobserver agreement. Change in elbow position did not affect the perceived displacement (P=0.82) with excellent intraobserver reliability (intraclass correlation coefficient range, 0.979 to 0.988) and interobserver agreement of 0.953. The intraclass correlation coefficient for intraobserver reliability on 45 degrees internal oblique films for all groups ranged from 0.985 to 0.998, with interobserver agreement of 0.953. For predicting displacement, the observers were 60% accurate in predicting the true displacement on the 45 degrees internal oblique films and only 35% accurate using the 60 degrees internal oblique view. Standardizing to a 45 degrees internal oblique radiograph of the elbow (regardless of elbow flexion) can augment the treating surgeon's ability to determine true displacement. At this degree of rotation, the measured number can be multiplied by 1.4 to better estimate displacement. The addition of a 45 degrees internal oblique radiograph in medial humeral epicondyle fractures has good

  5. The Reliability of Isometer 2 Device in Measuring of Cervical Flexor and Extensor Muscles Strength

    Directory of Open Access Journals (Sweden)

    Asghar Reza Soltan-Zadeh

    2006-07-01

    Full Text Available Objective: The strength of a group of muscles can be measured by muscle strength test, employing a force measuring instrument. In order to monitor the effectiveness of a therapeutic or training programs we need a reliable technique which is also accurate in repeated measurements. The purpose of this study was to examine the reliability of an isometric neck muscle force measurement device.  Materials & Methods: Thirty seven healthy non athlete subjects (18 males and 19 females, aged 18-25 participated in this analytical study. The maximal isometric contractions of the neck extensor and flexor muscles were measured in different times and different days and by two different testers. A new sensitive “load cell” was applied to our previously designed neck muscle force measurement apparatus. Results: The results of the inter-trail, test retest, and inter rater reliability (0.86 < ICC < 0.98 , 2.2< Sw <5.1 N indicated that the neck muscle force measurements were highly repeatable and less variable between measurements. There were no statistically significant differences in neck muscle force measurements, between times, between days and between retsters. Maximum isometric contractions were significantly higher in males than in the females (p < 0.001. Women’s neck muscle strengths were 30.8% and 46.1% of men in cervical extension and cervical flexion. Conclusion: In this study we used a new model (Isometer 2 of our previous apparatus (Isometer. The isometric strength of neck flexor and extensor muscles which was measured by Isometer 2 appeared to be a reliable and useful method for measuring the force of the neck extensor and flexor muscles.

  6. Fatigue is a reliable, sensitive and unique outcome measure in rheumatoid arthritis.

    LENUS (Irish Health Repository)

    Minnock, Patricia

    2009-12-01

    Fatigue is an important symptom in patients with RA. Measurement of fatigue in clinical trials and in clinical practice requires scales that are reproducible, sensitive to change and practical. This study examined the reliability and sensitivity to change of fatigue and its relative independence as an outcome measure in RA.

  7. Reliability and validity of an internet-based questionnaire measuring lifetime physical activity.

    Science.gov (United States)

    De Vera, Mary A; Ratzlaff, Charles; Doerfling, Paul; Kopec, Jacek

    2010-11-15

    Lifetime exposure to physical activity is an important construct for evaluating associations between physical activity and disease outcomes, given the long induction periods in many chronic diseases. The authors' objective in this study was to evaluate the measurement properties of the Lifetime Physical Activity Questionnaire (L-PAQ), a novel Internet-based, self-administered instrument measuring lifetime physical activity, among Canadian men and women in 2005-2006. Reliability was examined using a test-retest study. Validity was examined in a 2-part study consisting of 1) comparisons with previously validated instruments measuring similar constructs, the Lifetime Total Physical Activity Questionnaire (LT-PAQ) and the Chasan-Taber Physical Activity Questionnaire (CT-PAQ), and 2) a priori hypothesis tests of constructs measured by the L-PAQ. The L-PAQ demonstrated good reliability, with intraclass correlation coefficients ranging from 0.67 (household activity) to 0.89 (sports/recreation). Comparison between the L-PAQ and the LT-PAQ resulted in Spearman correlation coefficients ranging from 0.41 (total activity) to 0.71 (household activity); comparison between the L-PAQ and the CT-PAQ yielded coefficients of 0.58 (sports/recreation), 0.56 (household activity), and 0.50 (total activity). L-PAQ validity was further supported by observed relations between the L-PAQ and sociodemographic variables, consistent with a priori hypotheses. Overall, the L-PAQ is a useful instrument for assessing multiple domains of lifetime physical activity with acceptable reliability and validity.

  8. The reliability of a severity rating scale to measure stuttering in an unfamiliar language.

    Science.gov (United States)

    Hoffman, Laura; Wilson, Linda; Copley, Anna; Hewat, Sally; Lim, Valerie

    2014-06-01

    With increasing multiculturalism, speech-language pathologists (SLPs) are likely to work with stuttering clients from linguistic backgrounds that differ from their own. No research to date has estimated SLPs' reliability when measuring severity of stuttering in an unfamiliar language. Therefore, this study was undertaken to estimate the reliability of SLPs' use of a 9-point severity rating (SR) scale, to measure severity of stuttering in a language that was different from their own. Twenty-six Australian SLPs rated 20 speech samples (10 Australian English [AE] and 10 Mandarin) of adults who stutter using a 9-point SR scale on two separate occasions. Judges showed poor agreement when using the scale to measure stuttering in Mandarin samples. Results also indicated that 50% of individual judges were unable to reliably measure the severity of stuttering in AE. The results highlight the need for (a) SLPs to develop intra- and inter-judge agreement when using the 9-point SR scale to measure severity of stuttering in their native language (in this case AE) and in unfamiliar languages; and (b) research into the development and evaluation of practice and/or training packages to assist SLPs to do so.

  9. Reliability of force-velocity relationships during deadlift high pull.

    Science.gov (United States)

    Lu, Wei; Boyas, Sébastien; Jubeau, Marc; Rahmani, Abderrahmane

    2017-11-13

    This study aimed to evaluate the within- and between-session reliability of force, velocity and power performances and to assess the force-velocity relationship during the deadlift high pull (DHP). Nine participants performed two identical sessions of DHP with loads ranging from 30 to 70% of body mass. The force was measured by a force plate under the participants' feet. The velocity of the 'body + lifted mass' system was calculated by integrating the acceleration and the power was calculated as the product of force and velocity. The force-velocity relationships were obtained from linear regression of both mean and peak values of force and velocity. The within- and between-session reliability was evaluated by using coefficients of variation (CV) and intraclass correlation coefficients (ICC). Results showed that DHP force-velocity relationships were significantly linear (R² > 0.90, p  0.94), mean and peak velocities showed a good agreement (CV reliable and can therefore be utilised as a tool to characterise individuals' muscular profiles.

  10. Precise measurements of mass of Rb isotopes with A=91-97

    International Nuclear Information System (INIS)

    Alkhazov, G.D.; Belyaev, B.N.; Domkin, V.D.; Korobulin, Yu.G.; Lukashevich, V.V.; Mukhin, V.S.; AN SSSR, Leningrad

    1989-01-01

    A new scheme of the experiment on measuring the short-living nuclide atom masses, based on applying the isobar doublet method for mass scale gauging, is proposed. Results of measuring masses of Rb isotope atom with A=91-97, performed using a prism mass-spectrometer on line with the LiYaF mass-separator and synchrocyclotron with 30-80 keV error are presented

  11. Observation and mass measurement of the baryon Xib-.

    Science.gov (United States)

    Aaltonen, T; Abulencia, A; Adelman, J; Affolder, T; Akimoto, T; Albrow, M G; Amerio, S; Amidei, D; Anastassov, A; Anikeev, K; Annovi, A; Antos, J; Aoki, M; Apollinari, G; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Aurisano, A; Azfar, F; Azzi-Bacchetta, P; Azzurri, P; Bacchetta, N; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Baroiant, S; Bartsch, V; Bauer, G; Beauchemin, P-H; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Belloni, A; Benjamin, D; Beretvas, A; Beringer, J; Berry, T; Bhatti, A; Binkley, M; Bisello, D; Bizjak, I; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bolshov, A; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Byrum, K L; Cabrera, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carrillo, S; Carlsmith, D; Carosi, R; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, I; Cho, K; Chokheli, D; Chou, J P; Choudalakis, G; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Cilijak, M; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Coca, M; Compostella, G; Convery, M E; Conway, J; Cooper, B; Copic, K; Cordelli, M; Cortiana, G; Crescioli, F; Cuenca Almenar, C; Cuevas, J; Culbertson, R; Cully, J C; DaRonco, S; Datta, M; D'Auria, S; Davies, T; Dagenhart, D; de Barbaro, P; De Cecco, S; Deisher, A; De Lentdecker, G; De Lorenzo, G; Dell'Orso, M; Delli Paoli, F; Demortier, L; Deng, J; Deninno, M; De Pedis, D; Derwent, P F; Di Giovanni, G P; Dionisi, C; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Dörr, C; Donati, S; Dong, P; Donini, J; Dorigo, T; Dube, S; Efron, J; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, I; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Field, R; Flanagan, G; Forrest, R; Forrester, S; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garcia, J E; Garberson, F; Garfinkel, A F; Gay, C; Gerberich, H; Gerdes, D; Giagu, S; Giannetti, P; Gibson, K; Gimmell, J L; Ginsburg, C; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Goldstein, J; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Grinstein, S; Grosso-Pilcher, C; Group, R C; Grundler, U; Guimaraes da Costa, J; Gunay-Unalan, Z; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Hamilton, A; Han, B-Y; Han, J Y; Handler, R; Happacher, F; Hara, K; Hare, D; Hare, M; Harper, S; Harr, R F; Harris, R M; Hartz, M; Hatakeyama, K; Hauser, J; Hays, C; Heck, M; Heijboer, A; Heinemann, B; Heinrich, J; Henderson, C; Herndon, M; Heuser, J; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Holloway, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Husemann, U; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ivanov, A; Iyutin, B; James, E; Jang, D; Jayatilaka, B; Jeans, D; Jeon, E J; Jindariani, S; Johnson, W; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Karchin, P E; Kato, Y; Kemp, Y; Kephart, R; Kerzel, U; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Klute, M; Knuteson, B; Ko, B R; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kraan, A C; Kraus, J; Kreps, M; Kroll, J; Krumnack, N; Kruse, M; Krutelyov, V; Kubo, T; Kuhlmann, S E; Kuhr, T; Kulkarni, N P; Kusakabe, Y; Kwang, S; Laasanen, A T; Lai, S; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; LeCompte, T; Lee, J; Lee, J; Lee, Y J; Lee, S W; Lefèvre, R; Leonardo, N; Leone, S; Levy, S; Lewis, J D; Lin, C; Lin, C S; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, T; Lockyer, N S; Loginov, A; Loreti, M; Lu, R-S; Lucchesi, D; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Lytken, E; Mack, P; MacQueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maki, T; Maksimovic, P; Malde, S; Malik, S; Manca, G; Manousakis, A; Margaroli, F; Marginean, R; Marino, C; Marino, C P; Martin, A; Martin, M; Martin, V; Martínez, M; Martínez-Ballarín, R; Maruyama, T; Mastrandrea, P; Masubuchi, T; Matsunaga, H; Mattson, M E; Mazini, R; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzemer, S; Menzione, A; Merkel, P; Mesropian, C; Messina, A; Miao, T; Miladinovic, N; Miles, J; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyamoto, A; Moed, S; Moggi, N; Mohr, B; Moon, C S; Moore, R; Morello, M; Movilla Fernandez, P; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Mussini, M; Nachtman, J; Nagano, A; Naganoma, J; Nakamura, K; Nakano, I; Napier, A; Necula, V; Neu, C; Neubauer, M S; Nielsen, J; Nodulman, L; Norniella, O; Nurse, E; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Oldeman, R; Orava, R; Osterberg, K; Pagliarone, C; Palencia, E; Papadimitriou, V; Papaikonomou, A; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Piedra, J; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Portell, X; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Reisert, B; Rekovic, V; Renton, P; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Roy, P; Ruiz, A; Russ, J; Rusu, V; Saarikko, H; Safonov, A; Sakumoto, W K; Salamanna, G; Saltó, O; Santi, L; Sarkar, S; Sartori, L; Sato, K; Savard, P; Savoy-Navarro, A; Scheidle, T; Schlabach, P; Schmidt, E E; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scott, A L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sfyrla, A; Shalhout, S Z; Shapiro, M D; Shears, T; Shepard, P F; Sherman, D; Shimojima, M; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sinervo, P; Sisakyan, A; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soderberg, M; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spinella, F; Spreitzer, T; Squillacioti, P; Stanitzki, M; Staveris-Polykalas, A; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Stuart, D; Suh, J S; Sukhanov, A; Sun, H; Suslov, I; Suzuki, T; Taffard, A; Takashima, R; Takeuchi, Y; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Thom, J; Thompson, A S; Thomson, E; Tipton, P; Tiwari, V; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Tourneur, S; Trischuk, W; Tsuno, S; Tu, Y; Turini, N; Ukegawa, F; Uozumi, S; Vallecorsa, S; van Remortel, N; Varganov, A; Vataga, E; Vazquez, F; Velev, G; Vellidis, C; Veramendi, G; Veszpremi, V; Vidal, M; Vidal, R; Vila, I; Vilar, R; Vine, T; Vogel, M; Vollrath, I; Volobouev, I; Volpi, G; Würthwein, F; Wagner, P; Wagner, R G; Wagner, R L; Wagner, J; Wagner, W; Wallny, R; Wang, S M; Warburton, A; Waters, D; Weinberger, M; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wright, T; Wu, X; Wynne, S M; Yagil, A; Yamamoto, K; Yamaoka, J; Yamashita, T; Yang, C; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zaw, I; Zhang, X; Zhou, J; Zucchelli, S

    2007-08-03

    We report the observation and measurement of the mass of the bottom, strange baryon Xi(b)- through the decay chain Xi(b)- -->J/psiXi-, where J/psi-->mu+mu-, Xi- -->Lambdapi-, and Lambda-->ppi-. A signal is observed whose probability of arising from a background fluctuation is 6.6 x 10(-15), or 7.7 Gaussian standard deviations. The Xi(b)- mass is measured to be 5792.9+/-2.5(stat) +/- 1.7(syst) MeV/c2.

  12. Measurement of the W mass in $e^+ e^-$ annihilation

    CERN Document Server

    Juste, A

    1998-01-01

    A measurement of the W mass in the fully hadronic decay channel from the data sample collected by ALEPH during 1996 at centre-of-mass energies of 161 and 172 GeV is presented. At 161 GeV, the W mass is derived from the cross-section measurement taking advantage of the high sensitivity close to the production threshold. Due to the presence of large backgrounds, a multidimensional analysis based on Neural Network techniques is developed. By combining the measurements in all decay channels and the four LEP experiments, a precision in the W mass of $\\pm 220$ MeV is finally obtained. At 172 GeV, the W mass is obtained from the direct reconstruction of the final state kinematics. The fully hadronic decay channel becomes particularly difficult due to the large existing background and the important distortions due to fragmentation and detector effects when reconstructing four hadronic jets in the final state. In addition, in this channel there is the intrinsic difficulty associated with the combinatorial background. ...

  13. CAN THE MASSES OF ISOLATED PLANETARY-MASS GRAVITATIONAL LENSES BE MEASURED BY TERRESTRIAL PARALLAX?

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, M.; Botzler, C. S.; Bray, J. C.; Cherrie, J. M.; Rattenbury, N. J. [Department of Physics, University of Auckland, Private Bag 92019, Auckland 1142 (New Zealand); Philpott, L. C. [Department of Earth, Ocean and Atmospheric Sciences, University of British Columbia, Vancouver, British Columbia V6T 1Z4 (Canada); Abe, F.; Muraki, Y. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya 464-8601 (Japan); Albrow, M. D. [Department of Physics and Astronomy, University of Canterbury, P.O. Box 4800, Christchurch 8020 (New Zealand); Bennett, D. P. [Department of Physics, 225 Nieuwland Science Hall, University of Notre Dame, Notre Dame, IN 46556 (United States); Bond, I. A. [Institute for Information and Mathematical Sciences, Massey University, Private Bag 102-904, Auckland 1330 (New Zealand); Christie, G. W.; Natusch, T. [Auckland Observatory, PO Box 180, Royal Oak, Auckland 1345 (New Zealand); Dionnet, Z. [Université d' Orsay, bat 470, F-91400 Orsay (France); Gould, A. [Department of Astronomy, Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Han, C. [Department of Physics, Chungbuk National University, 410 Seongbong-Rho, Hungduk-Gu, Chongju 371-763 (Korea, Republic of); Heyrovský, D. [Institute of Theoretical Physics, Charles University in Prague, Faculty of Mathematics and Physics, V Holesovickach 2, 18000 Prague (Czech Republic); McCormick, J. M. [Farm Cove Observatory, 2/24 Rapallo Place, Pakuranga, Auckland 2012 (New Zealand); Moorhouse, D. M. [Kumeu Observatory, Kumeu (New Zealand); Skowron, J., E-mail: mfre070@aucklanduni.ac.nz [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478, Warszawa (Poland); and others

    2015-02-01

    Recently Sumi et al. reported evidence for a large population of planetary-mass objects (PMOs) that are either unbound or orbit host stars in orbits ≥10 AU. Their result was deduced from the statistical distribution of durations of gravitational microlensing events observed by the MOA collaboration during 2006 and 2007. Here we study the feasibility of measuring the mass of an individual PMO through microlensing by examining a particular event, MOA-2011-BLG-274. This event was unusual as the duration was short, the magnification high, the source-size effect large, and the angular Einstein radius small. Also, it was intensively monitored from widely separated locations under clear skies at low air masses. Choi et al. concluded that the lens of the event may have been a PMO but they did not attempt a measurement of its mass. We report here a re-analysis of the event using re-reduced data. We confirm the results of Choi et al. and attempt a measurement of the mass and distance of the lens using the terrestrial parallax effect. Evidence for terrestrial parallax is found at a 3σ level of confidence. The best fit to the data yields the mass and distance of the lens as 0.80 ± 0.30 M {sub J} and 0.80 ± 0.25 kpc respectively. We exclude a host star to the lens out to a separation ∼40 AU. Drawing on our analysis of MOA-2011-BLG-274 we propose observational strategies for future microlensing surveys to yield sharper results on PMOs including those down to super-Earth mass.

  14. Relating measurement invariance, cross-level invariance, and multilevel reliability

    OpenAIRE

    Jak, S.; Jorgensen, T.D.

    2017-01-01

    Data often have a nested, multilevel structure, for example when data are collected from children in classrooms. This kind of data complicate the evaluation of reliability and measurement invariance, because several properties can be evaluated at both the individual level and the cluster level, as well as across levels. For example, cross-level invariance implies equal factor loadings across levels, which is needed to give latent variables at the two levels a similar interpretation. Reliabili...

  15. ISOLTRAP Mass Measurements for Weak-Interaction Studies

    International Nuclear Information System (INIS)

    Kellerbauer, A.; Delahaye, P.; Herlert, A.; Audi, G.; Guenaut, C.; Lunney, D.; Beck, D.; Herfurth, F.; Kluge, H.-J.; Mukherjee, M.; Rodriguez, D.; Weber, C.; Yazidjian, C.; Blaum, K.; Bollen, G.; Schwarz, S.; George, S.; Schweikhard, L.

    2006-01-01

    The conserved-vector-current (CVC) hypothesis of the weak interaction and the unitarity of the Cabibbo-Kobayashi-Maskawa (CKM) matrix are two fundamental postulates of the Standard Model. While existing data on CVC supports vector current conservation, the unitarity test of the CKM matrix currently fails by more than two standard deviations. High-precision mass measurements performed with the ISOLTRAP experiment at ISOLDE/CERN provide crucial input for these fundamental studies by greatly improving our knowledge of the decay energy of super-allowed β decays. Recent results of mass measurements on the β emitters 18Ne, 22Mg, 34Ar, and 74Rb as pertaining to weak-interaction studies are presented

  16. Measurement of the W boson mass with the ATLAS detector

    International Nuclear Information System (INIS)

    Kivernyk, Oleh

    2016-01-01

    This thesis describes a measurement of the W boson mass with the ATLAS detector based on the data-set recorded by ATLAS in 2011 at a centre-of-mass energy of 7 TeV, and corresponding to 4.6 inverse femto-barn of integrated luminosity. Measurements are performed through template fits to the transverse momentum distributions of charged leptons and to transverse mass distributions of the W boson, in electron and muon decay modes in various kinematic categories. The individual measurements are found to be consistent and their combination leads to a value of m W = 80371.1 ± 18.6 MeV. The measured value of the W boson mass is compatible with the current world average of m W = 80385 ± 15 MeV. The uncertainty is competitive with the current most precise measurements performed by the CDF and D0 collaborations. (author) [fr

  17. Reliability of Eustachian tube function measurements in a hypobaric and hyperbaric pressure chamber.

    Science.gov (United States)

    Meyer, M F; Jansen, S; Mordkovich, O; Hüttenbrink, K-B; Beutner, D

    2017-12-01

    Measurement of the Eustachian tube (ET) function is a challenge. The demand for a precise and meaningful diagnostic tool increases-especially because more and more operative therapies are being offered without objective evidence. The measurement of the ET function by continuous impedance recording in a pressure chamber is an established method, although the reliability of the measurements is still unclear. Twenty-five participants (50 ears) were exposed to phases of compression and decompression in a hypo- and hyperbaric pressure chamber. The ET function reflecting parameters-ET opening pressure (ETOP), ET opening duration (ETOD) and ET opening frequency (ETOF)-were determined under exactly the same preconditions three times in a row. The intraclass correlation coefficient (ICC) and Bland and Altman plot were used to assess test-retest reliability. ICCs revealed a high correlation for ETOP and ETOF in phases of decompression (passive equalisation) as well as ETOD and ETOP in phases of compression (active induced equalisation). Very high correlation could be shown for ETOD in decompression and ETOF in compression phases. The Bland and Altman graphs could show that measurements provide results within a 95 % confidence interval in compression and decompression phases. We conclude that measurements in a pressure chamber are a very valuable tool in terms of estimating the ET opening and closing function. Measurements show some variance comparing participants, but provide reliable results within a 95 % confidence interval in retest. This study is the basis for enabling efficacy measurements of ET treatment modalities. © 2017 John Wiley & Sons Ltd.

  18. Onsets of nuclear deformation from measurements with the Isoltrap mass spectrometer

    CERN Document Server

    Naimi, Sarah

    Mass measurements provide important information concerning nuclear structure. This work presents results from the pioneering Penning trap spectrometer ISOLTRAP at CERN-ISOLDE. High-precision mass measurements of neutron-rich manganese ($^{58−66}$Mn) and krypton isotopes ($^{96,97}$Kr) are presented, of which the $^{66}$Mn and $^{96,97}$Kr masses are measured for the first time. In particular, the mass of $^{97}$Kr was measured using the preparation trap and required the definition of a new fit function. In the case of the manganese isotopes, the N = 40 shell closure is addressed. The two-neutron-separation energies calculated from the new masses show no shell closure at N = 40 but give an estimation of the proton-neutron interaction (around 0.5 MeV) responsible for the increase of collectivity and nuclear deformation in this mass region. The new krypton masses show behavior in sharp contrast with heavier neighbors where sudden and intense deformation is present, interpreted as the establishment of a nuclea...

  19. High precision mass measurements in Ψ and Υ families revisited

    International Nuclear Information System (INIS)

    Artamonov, A.S.; Baru, S.E.; Blinov, A.E.

    2000-01-01

    High precision mass measurements in Ψ and Υ families performed in 1980-1984 at the VEPP-4 collider with OLYA and MD-1 detectors are revisited. The corrections for the new value of the electron mass are presented. The effect of the updated radiative corrections has been calculated for the J/Ψ(1S) and Ψ(2S) mass measurements [ru

  20. Measurement of the D* (+) -D+ Mass Difference

    NARCIS (Netherlands)

    Lees, J. P.; Poireau, V.; Tisserand, V.; Grauges, E.; Palano, A.; Eigen, G.; Brown, D. N.; Kolomensky, Yu. G.; Fritsch, M.; Schroeder, T.; Hearty, C.; Mattison, T. S.; McKenna, J. A.; So, R. Y.; Blinov, V. E.; Buzykaev, A. R.; Druzhinin, V. P.; Golubev, V. B.; Kravchenko, E. A.; Onuchin, A. P.; Serednyakov, S. I.; Skovpen, Yu. I.; Solodov, E. P.; Todyshev, K. Yu.; Lankford, A. J.; Gary, J. W.; Long, O.; Eisner, A. M.; Lockman, W. S.; Vazquez, W. Panduro; Chao, D. S.; Echenard, B.; Flood, K. T.; Hitlin, D. G.; Miyashita, T. S.; Ongmongkolkul, P.; Rohrken, M.; Huard, Z.; Meadows, B. T.; Pushpawela, B. G.; Sokoloff, M. D.; Smith, J. G.; Wagner, S. R.; Bernard, D.; Verderi, M.; Bettoni, D.; Bozzi, C.; Calabrese, R.; Cibinetto, G.; Fioravanti, E.; Garzia, I.; Luppi, E.; Santoro, V.; Calcaterra, A.; de Sangro, R.; Finocchiaro, G.; Martellotti, S.; Patteri, P.; Peruzzi, I. M.; Piccolo, M.; Rotondo, M.; Zallo, A.; Passaggio, S.; Patrignani, C.; Lacker, H. M.; Bhuyan, B.; Mallik, U.; Cochran, J.; Prell, S.; Ahmed, H.; Gritsan, A. V.; Arnaud, N.; Davier, M.; Le Diberder, F.; Lutz, A. M.; Wormser, G.; Lange, D. J.; Wright, D. M.; Coleman, J. P.; Gabathuler, E.; Hutchcroft, D. E.; Payne, D. J.; Touramanis, C.; Bevan, A. J.; Di Lodovico, F.; Sacco, R.; Cowan, G.; Banerjee, Sw.; Brown, D. N.; Davis, C. L.; Denig, A. G.; Gradl, W.; Griessinger, K.; Hafner, A.; Schubert, K. R.; Barlow, R. J.; Lafferty, G. D.; Cenci, R.; Jawahery, A.; Roberts, D. A.; Cowan, R.; Robertson, S. H.; Dey, B.; Neri, N.; Palombo, F.; Cheaib, R.; Cremaldi, L.; Godang, R.; Summers, D. J.; Taras, P.; De Nardo, G.; Sciacca, C.; Raven, G.; Jessop, C. P.; LoSecco, J. M.; Honscheid, K.; Kass, R.; Gaz, A.; Margoni, M.; Posocco, M.; Simi, G.; Simonetto, F.; Stroili, R.; Akar, S.; Ben-Haim, E.; Bomben, M.; Bonneaud, G. R.; Calderini, G.; Chauveau, J.; Marchiori, G.; Ocariz, J.; Biasini, M.; Manoni, E.; Rossi, A.; Batignani, G.; Bettarini, S.; Carpinelli, M.; Casarosa, G.; Chrzaszcz, M.; Forti, F.; Giorgi, M. A.; Lusiani, A.; Oberhof, B.; Paoloni, E.; Rama, M.; Rizzo, G.; Walsh, J. J.; Smith, A. J. S.; Anulli, F.; Faccini, R.; Ferrarotto, F.; Ferroni, F.; Pilloni, A.; Piredda, G.; Buenger, C.; Dittrich, S.; Gruenberg, O.; Hess, M.; Leddig, T.; Voss, C.; Waldi, R.; Adye, T.; Wilson, F. F.; Emery, S.; Vasseur, G.; Aston, D.; Cartaro, C.; Convery, M. R.; Dorfan, J.; Dunwoodie, W.; Ebert, M.; Field, R. C.; Fulsom, B. G.; Graham, M. T.; Hast, C.; Innes, W. R.; Kim, P.; Leith, D. W. G. S.; Luitz, S.; MacFarlane, D. B.; Muller, D. R.; Neal, H.; Ratcliff, B. N.; Roodman, A.; Sullivan, M. K.; Va'vra, J.; Wisniewski, W. J.; Purohit, M. V.; Wilson, J. R.; Randle-Conde, A.; Sekula, S. J.; Bellis, M.; Burchat, P. R.; Puccio, E. M. T.; Alam, M. S.; Ernst, J. A.; Gorodeisky, R.; Guttman, N.; Peimer, D. R.; Soffer, A.; Spanier, S. M.; Ritchie, J. L.; Schwitters, R. F.; Izen, J. M.; Lou, X. C.; Bianchi, F.; De Mori, F.; Filippi, A.; Gamba, D.; Lanceri, L.; Vitale, L.; Martinez-Vidal, F.; Oyanguren, A.; Albert, J.; Beaulieu, A.; Bernlochner, F. U.; Kowalewski, R.; Lueck, T.; Nugent, I. M.; Roney, J. M.; Sobie, R. J.; Tasneem, N.; Gershon, T. J.; Harrison, P. F.; Latham, T. E.; Prepost, R.; Sun, L.

    2017-01-01

    We measure the mass difference, Δm+, between the D∗(2010)+ and the D+ using the decay chain D∗(2010)+→D+π0 with D+→K−π+π+. The data were recorded with the BABAR detector at center-of-mass energies at and near the Υ(4S) resonance, and correspond to an integrated luminosity of approximately 468  fb−1.

  1. Direct measurements of neutrino mass

    International Nuclear Information System (INIS)

    Robertson, R.G.H.

    1991-01-01

    Some recent developments in the experimental search for neutrino mass are discussed. New data from Los Alamos on the electron neutrino mass as measured in tritium beta decay give an upper limit of 9.3 eV at the 95% confidence level. This result is not consistent with the long-standing ITEP result of 26(5) eV within a ''model-independent'' range of 17 to 40 eV. It now appears that the electron neutrino is not sufficiently massive to close the universe by itself. Hime and Jelley report finding new evidence for a 17-keV neutrino in the Β decay of 35 S and 63 Ni. Many other experiments are being reported and the situation is still unresolved. 56 refs., 1 fig., 3 tabs

  2. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Directory of Open Access Journals (Sweden)

    Paschalis EI

    2014-01-01

    Full Text Available Eleftherios I Paschalis,* Fabiano Cade,* Samir Melki, Louis R Pasquale, Claes H Dohlman, Joseph B CiolinoMassachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA*These authors contributed equally to this workPurpose: To present an autonomous intraocular pressure (IOP measurement technique using a wireless implantable transducer (WIT and a motion sensor.Methods: The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline IOP.Results: On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg and mean vehicle IOP (13.27±2.1 mmHg (P=0.45, suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001, and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001. Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001. Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute, during which the IOP is not expected to change.Conclusion: IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.Keywords: IOP, pressure transducer, wireless, MEMS, implant, intraocular

  3. The Reliability and Validity of Discrete and Continuous Measures of Psychopathology: A Quantitative Review

    Science.gov (United States)

    Markon, Kristian E.; Chmielewski, Michael; Miller, Christopher J.

    2011-01-01

    In 2 meta-analyses involving 58 studies and 59,575 participants, we quantitatively summarized the relative reliability and validity of continuous (i.e., dimensional) and discrete (i.e., categorical) measures of psychopathology. Overall, results suggest an expected 15% increase in reliability and 37% increase in validity through adoption of a…

  4. Strength Measurements in Acute Hamstring Injuries: Intertester Reliability and Prognostic Value of Handheld Dynamometry.

    Science.gov (United States)

    Reurink, Gustaaf; Goudswaard, Gert Jan; Moen, Maarten H; Tol, Johannes L; Verhaar, Jan A N; Weir, Adam

    2016-08-01

    Study Design Cohort study, repeated measures. Background Although hamstring strength measurements are used for assessing prognosis and monitoring recovery after hamstring injury, their actual clinical relevance has not been established. Handheld dynamometry (HHD) is a commonly used method of measuring muscle strength. The reliability of HHD has not been determined in athletes with acute hamstring injuries. Objectives To determine the intertester reliability and the prognostic value of hamstring HHD strength measurement in acute hamstring injuries. Methods We measured knee flexion strength with HHD in 75 athletes at 2 visits, at baseline (within 5 days of hamstring injury) and follow-up (5 to 7 days after the baseline measurement). We assessed isometric hamstring strength in 15° and 90° of knee flexion. Reliability analysis testing was performed by 2 testers independently at the follow-up visit. We recorded the time needed to return to play (RTP) up to 6 months following baseline. Results The intraclass correlation coefficients of the strength measurements in injured hamstrings were between 0.75 and 0.83. There was a statistically significant but weak correlation between the time to RTP and the strength deficit at 15° of knee flexion measured at baseline (Spearman r = 0.25, P = .045) and at the follow-up visit (Spearman r = 0.26, P = .034). Up to 7% of the variance in time to RTP is explained by this strength deficit. None of the other strength variables were significantly correlated with time to RTP. Conclusion Hamstring strength can be reliably measured with HHD in athletes with acute hamstring injuries. The prognostic value of strength measurements is limited, as there is only a weak association between the time to RTP and hamstring strength deficit after acute injury. Level of Evidence Prognosis, level 4. J Orthop Sports Phys Ther 2016;46(8):689-696. Epub 12 May 2016. doi:10.2519/jospt.2016.6363.

  5. Reliability and Validity of the Turkish Version of the Voice-Related Quality of Life Measure.

    Science.gov (United States)

    Tezcaner, Zahide Çiler; Aksoy, Songül

    2017-03-01

    This study aims to test the validity and reliability of the Turkish version of the Voice-Related Quality of Life (V-RQOL) questionnaire. This is a nonrandomized, prospective study with control group. The questionnaire was administered to 249 individuals-130 with vocal complaint and 119 without-with a mean age of 37.8 ± 12.3 years. The Turkish version of the Voice Handicap Index (VHI) and perceptual voice evaluation measures were also administered at 2-14 days for retest reliability. The instrument was submitted to validity and reliability evaluation. The V-RQOL measure showed a strong internal consistency and test-retest reliability; the Cronbach's alpha coefficient for the overall V-RQOL was 0.969, the physical functioning domain was 0.949, and the social-emotional domain was 0.940. In the test-retest reliability test, the overall V-RQOL was found to be 0.989. The construct validity of the V-RQOL was determined based on the strength and direction of its relation to the VHI and the perceptual voice evaluation measure. The higher the VHI level, the lower the physical functioning, social-emotional, and overall score levels of the V-RQOL (r = -0.927, r = -0.912, r = -0.944, respectively; P reliability and validity and may play a crucial role in evaluating Turkish-speaking patients with voice disorders. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  6. Mass measurements on short-lived Cd and Ag nuclides at the online mass spectrometer ISOLTRAP

    Energy Technology Data Exchange (ETDEWEB)

    Breitenfeldt, Martin

    2009-07-03

    the rp process that will enable a more reliable determination of the composition of the produced material at A = 99. It has been shown that the mass of {sup 99}Cd strongly affects the A = 99 production in an X-ray burst model, and that uncertainties have been significantly reduced from more than an order of magnitude to about a factor of 3. The dominant source of uncertainty is now the mass of {sup 100}In. In principle, other uncertainties will also contribute. These include those of masses of lighter Cd isotopes, where similar rp-process branchpoints occur and which might affect feeding into the {sup 99}Cd branchpoint. In addition, nuclear reaction rate uncertainties will also play a role. However, as reaction rates affect branchings in a linear fashion, while mass differences enter exponentially, mass uncertainties will tend to dominate [Sch06]. Also, which reaction rates are important depends largely on nuclear masses. For example, for low S{sub p}({sup 100}In) a (p,{gamma})-({gamma},p) equilibrium will be established between {sup 99}Cd and {sup 100}In and the {sup 100}In(p,{gamma}) reaction rate would affect the A = 99 production, while for larger S{sub p}({sup 100}In) the {sup 99}Cd(p,{gamma}) reaction rate might be more relevant. Therefore, the mass uncertainties should be addressed first. Once they are under control, further improvements might be possible by constraining proton capture rates. The presented results are relevant for any rp-process scenario with a reaction flow through the {sup 99}Cd region. Here, an X-ray burst model has been used to investigate in detail the impact of the present measurements on such an rp process. The {nu}p process in core collapse supernovae might be another possible scenario for an rp process in the {sup 99}Cd region. It it is planed to also explore whether in that case mass uncertainties have a similar impact on the final composition. On the neutron-rich side of the valley of stability for the Cd and Ag chains of nuclides

  7. Reliability and validity of the Pragmatics Observational Measure (POM): a new observational measure of pragmatic language for children.

    Science.gov (United States)

    Cordier, Reinie; Munro, Natalie; Wilkes-Gillan, Sarah; Speyer, Renée; Pearce, Wendy M

    2014-07-01

    There is a need for a reliable and valid assessment of childhood pragmatic language skills during peer-peer interactions. This study aimed to evaluate the psychometric properties of a newly developed pragmatic assessment, the Pragmatic Observational Measure (POM). The psychometric properties of the POM were investigated from observational data of two studies - study 1 involved 342 children aged 5-11 years (108 children with ADHD; 108 typically developing playmates; 126 children in the control group), and study 2 involved 9 children with ADHD who attended a 7-week play-based intervention. The psychometric properties of the POM were determined based on the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) taxonomy of psychometric properties and definitions for health-related outcomes; the Pragmatic Protocol was used as the reference tool against which the POM was evaluated. The POM demonstrated sound psychometric properties in all the reliability, validity and interpretability criteria against which it was assessed. The findings showed that the POM is a reliable and valid measure of pragmatic language skills of children with ADHD between the age of 5 and 11 years and has clinical utility in identifying children with pragmatic language difficulty. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. First Direct Mass Measurements of Nuclides around Z =100 with a Multireflection Time-of-Flight Mass Spectrograph

    Science.gov (United States)

    Ito, Y.; Schury, P.; Wada, M.; Arai, F.; Haba, H.; Hirayama, Y.; Ishizawa, S.; Kaji, D.; Kimura, S.; Koura, H.; MacCormick, M.; Miyatake, H.; Moon, J. Y.; Morimoto, K.; Morita, K.; Mukai, M.; Murray, I.; Niwase, T.; Okada, K.; Ozawa, A.; Rosenbusch, M.; Takamine, A.; Tanaka, T.; Watanabe, Y. X.; Wollnik, H.; Yamaki, S.

    2018-04-01

    The masses of 246Es, 251Fm, and the transfermium nuclei Md-252249 and 254No, produced by hot- and cold-fusion reactions, in the vicinity of the deformed N =152 neutron shell closure, have been directly measured using a multireflection time-of-flight mass spectrograph. The masses of 246Es and 249,250,252Md were measured for the first time. Using the masses of Md,250249 as anchor points for α decay chains, the masses of heavier nuclei, up to 261Bh and 266Mt, were determined. These new masses were compared with theoretical global mass models and demonstrated to be in good agreement with macroscopic-microscopic models in this region. The empirical shell gap parameter δ2 n derived from three isotopic masses was updated with the new masses and corroborates the existence of the deformed N =152 neutron shell closure for Md and Lr.

  9. Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program

    Science.gov (United States)

    Sled, Elizabeth A.; Sheehy, Lisa M.; Felson, David T.; Costigan, Patrick A.; Lam, Miu; Cooke, T. Derek V.

    2010-01-01

    The objective of the study was to evaluate the reliability of frontal plane lower limb alignment measures using a landmark-based method by (1) comparing inter- and intra-reader reliability between measurements of alignment obtained manually with those using a computer program, and (2) determining inter- and intra-reader reliability of computer-assisted alignment measures from full-limb radiographs. An established method for measuring alignment was used, involving selection of 10 femoral and tibial bone landmarks. 1) To compare manual and computer methods, we used digital images and matching paper copies of five alignment patterns simulating healthy and malaligned limbs drawn using AutoCAD. Seven readers were trained in each system. Paper copies were measured manually and repeat measurements were performed daily for 3 days, followed by a similar routine with the digital images using the computer. 2) To examine the reliability of computer-assisted measures from full-limb radiographs, 100 images (200 limbs) were selected as a random sample from 1,500 full-limb digital radiographs which were part of the Multicenter Osteoarthritis (MOST) Study. Three trained readers used the software program to measure alignment twice from the batch of 100 images, with two or more weeks between batch handling. Manual and computer measures of alignment showed excellent agreement (intraclass correlations [ICCs] 0.977 – 0.999 for computer analysis; 0.820 – 0.995 for manual measures). The computer program applied to full-limb radiographs produced alignment measurements with high inter- and intra-reader reliability (ICCs 0.839 – 0.998). In conclusion, alignment measures using a bone landmark-based approach and a computer program were highly reliable between multiple readers. PMID:19882339

  10. Workplace aerosol mass concentration measurement using optical particle counters.

    Science.gov (United States)

    Görner, Peter; Simon, Xavier; Bémer, Denis; Lidén, Göran

    2012-02-01

    Direct-reading aerosol measurement usually uses the optical properties of airborne particles to detect and measure particle concentration. In the case of occupational hygiene, mass concentration measurement is often required. Two aerosol monitoring methods are based on the principle of light scattering: optical particle counting (OPC) and photometry. The former analyses the light scattered by a single particle, the latter by a cloud of particles. Both methods need calibration to transform the quantity of scattered light detected into particle concentration. Photometers are simpler to use and can be directly calibrated to measure mass concentration. However, their response varies not only with aerosol concentration but also with particle size distribution, which frequently contributes to biased measurement. Optical particle counters directly measure the particle number concentration and particle size that allows assessment of the particle mass provided the particles are spherical and of known density. An integrating algorithm is used to calculate the mass concentration of any conventional health-related aerosol fraction. The concentrations calculated thus have been compared with simultaneous measurements by conventional gravimetric sampling to check the possibility of field OPC calibration with real workplace aerosols with a view to further monitoring particle mass concentration. Aerosol concentrations were measured in the food industry using the OPC GRIMM® 1.108 and the CIP 10-Inhalable and CIP 10-Respirable (ARELCO®) aerosol samplers while meat sausages were being brushed and coated with calcium carbonate. Previously, the original OPC inlet had been adapted to sample inhalable aerosol. A mixed aerosol of calcium carbonate and fungi spores was present in the workplace. The OPC particle-size distribution and an estimated average particle density of both aerosol components were used to calculate the mass concentration. The inhalable and respirable aerosol fractions

  11. Reliability of a single objective measure in assessing sleepiness.

    Science.gov (United States)

    Sunwoo, Bernie Y; Jackson, Nicholas; Maislin, Greg; Gurubhagavatula, Indira; George, Charles F; Pack, Allan I

    2012-01-01

    To evaluate reliability of single objective tests in assessing sleepiness. Subjects who completed polysomnography underwent a 4-nap multiple sleep latency test (MSLT) the following day. Prior to each nap opportunity on MSLT, subjects performed the psychomotor vigilance test (PVT) and divided attention driving task (DADT). Results of single versus multiple test administrations were compared using the intraclass correlation coefficient (ICC) and adjusted for test administration order effects to explore time of day effects. Measures were explored as continuous and binary (i.e., impaired or not impaired). Community-based sample evaluated at a tertiary, university-based sleep center. 372 adult commercial vehicle operators oversampled for increased obstructive sleep apnea risk. N/A. AS CONTINUOUS MEASURES, ICC WERE AS FOLLOWS: MSLT 0.45, PVT median response time 0.69, PVT number of lapses 0.51, 10-min DADT tracking error 0.87, 20-min DADT tracking error 0.90. Based on binary outcomes, ICC were: MSLT 0.63, PVT number of lapses 0.85, 10-min DADT 0.95, 20-min DADT 0.96. Statistically significant time of day effects were seen in both the MSLT and PVT but not the DADT. Correlation between ESS and different objective tests was strongest for MSLT, range [-0.270 to -0.195] and persisted across all time points. Single DADT and PVT administrations are reliable measures of sleepiness. A single MSLT administration can reasonably discriminate individuals with MSL < 8 minutes. These results support the use of a single administration of some objective tests of sleepiness when performed under controlled conditions in routine clinical care.

  12. Inter-rater reliability of kinesthetic measurements with the KINARM robotic exoskeleton.

    Science.gov (United States)

    Semrau, Jennifer A; Herter, Troy M; Scott, Stephen H; Dukelow, Sean P

    2017-05-22

    Kinesthesia (sense of limb movement) has been extremely difficult to measure objectively, especially in individuals who have survived a stroke. The development of valid and reliable measurements for proprioception is important to developing a better understanding of proprioceptive impairments after stroke and their impact on the ability to perform daily activities. We recently developed a robotic task to evaluate kinesthetic deficits after stroke and found that the majority (~60%) of stroke survivors exhibit significant deficits in kinesthesia within the first 10 days post-stroke. Here we aim to determine the inter-rater reliability of this robotic kinesthetic matching task. Twenty-five neurologically intact control subjects and 15 individuals with first-time stroke were evaluated on a robotic kinesthetic matching task (KIN). Subjects sat in a robotic exoskeleton with their arms supported against gravity. In the KIN task, the robot moved the subjects' stroke-affected arm at a preset speed, direction and distance. As soon as subjects felt the robot begin to move their affected arm, they matched the robot movement with the unaffected arm. Subjects were tested in two sessions on the KIN task: initial session and then a second session (within an average of 18.2 ± 13.8 h of the initial session for stroke subjects), which were supervised by different technicians. The task was performed both with and without the use of vision in both sessions. We evaluated intra-class correlations of spatial and temporal parameters derived from the KIN task to determine the reliability of the robotic task. We evaluated 8 spatial and temporal parameters that quantify kinesthetic behavior. We found that the parameters exhibited moderate to high intra-class correlations between the initial and retest conditions (Range, r-value = [0.53-0.97]). The robotic KIN task exhibited good inter-rater reliability. This validates the KIN task as a reliable, objective method for quantifying

  13. Extending Penning trap mass measurements with SHIPTRAP to the heaviest elements

    International Nuclear Information System (INIS)

    Block, M.; Ackermann, D.; Herfurth, F.; Hofmann, S.; Blaum, K.; Droese, C.; Marx, G.; Schweikhard, L.; Düllmann, Ch. E.; Eibach, M.; Eliseev, S.; Haettner, E.; Plaß, W. R.; Scheidenberger, C.; Heßberger, F. P.; Ramirez, E. Minaya; Nesterenko, D.

    2013-01-01

    Penning-trap mass spectrometry of radionuclides provides accurate mass values and absolute binding energies. Such mass measurements are sensitive indicators of the nuclear structure evolution far away from stability. Recently, direct mass measurements have been extended to the heavy elements nobelium (Z=102) and lawrencium (Z=103) with the Penning-trap mass spectrometer SHIPTRAP. The results probe nuclear shell effects at N=152. New developments will pave the way to access even heavier nuclides.

  14. An Improved W Boson Mass Measurement Using the Collider Detector at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Yu [Duke Univ., Durham, NC (United States)

    2012-01-01

    The mass of the W boson is one of the most important parameters in the Standard Model. A precise measurement of the W boson mass, together with a precise measurement of the top quark mass, can constrain the mass of the undiscovered Higgs boson within the Standard Model framework or give a hint for physics beyond the Standard Model. This dissertation describes a measurement of the W boson mass through its decay into a muon and a neutrino using ~ 2.2 fb-1 of √ s = 1.96 TeV p$\\bar{p}$ data taken with the CDF II detector at Fermilab. We measure the W boson mass to be (80.374 ± 0.015stat. ± 0.016syst.) GeV/c2. This result, when combined with the W mass measurement in the electron channel, leads to the single most precise mW value and greatly constrains the possible mass range of the undiscovered Higgs boson. iv

  15. Computational area measurement of orbital floor fractures: Reliability, accuracy and rapidity

    International Nuclear Information System (INIS)

    Schouman, Thomas; Courvoisier, Delphine S.; Imholz, Benoit; Van Issum, Christopher; Scolozzi, Paolo

    2012-01-01

    Objective: To evaluate the reliability, accuracy and rapidity of a specific computational method for assessing the orbital floor fracture area on a CT scan. Method: A computer assessment of the area of the fracture, as well as that of the total orbital floor, was determined on CT scans taken from ten patients. The ratio of the fracture's area to the orbital floor area was also calculated. The test–retest precision of measurement calculations was estimated using the Intraclass Correlation Coefficient (ICC) and Dahlberg's formula to assess the agreement across observers and across measures. The time needed for the complete assessment was also evaluated. Results: The Intraclass Correlation Coefficient across observers was 0.92 [0.85;0.96], and the precision of the measures across observers was 4.9%, according to Dahlberg's formula .The mean time needed to make one measurement was 2 min and 39 s (range, 1 min and 32 s to 4 min and 37 s). Conclusion: This study demonstrated that (1) the area of the orbital floor fracture can be rapidly and reliably assessed by using a specific computer system directly on CT scan images; (2) this method has the potential of being routinely used to standardize the post-traumatic evaluation of orbital fractures

  16. Direct measurements of neutrino masses

    Energy Technology Data Exchange (ETDEWEB)

    Holzschuh, E [Zurich Univ. (Switzerland). Inst. fuer Physik

    1996-11-01

    The direct measurements have so far given no indication for a nonzero (positive) mass of any of the three known neutrinos. The experiments measuring the tau and the muon neutrino are good shape. The tritium experiments are in an unfortunate situation. It is unclear to me whether the problems are experimental or theoretical or a combination of both. The electronic final states distribution have been calculated, but the results have never been tested experimentally. The most important question to be answered is about the validity of the sudden approximation. (author) 9 figs., 2 tabs., 16 refs.

  17. Reliability of measuring pelvic floor elevation with a diagnostic ultrasonic imaging device

    OpenAIRE

    Ubukata, Hitomi; Maruyama, Hitoshi; Huo, Ming

    2015-01-01

    [Purpose] The purpose of this study was to investigate the reliability of measuring the amount of pelvic floor elevation during pelvic and abdominal muscle contraction with a diagnostic ultrasonic imaging device. [Subjects] The study group comprised 11 healthy women without urinary incontinence or previous birth experience. [Methods] We measured the displacement elevation of the bladder base during contraction of the abdominal and pelvic floor muscles was measured using a diagnostic ultrasoni...

  18. High-accuracy mass measurements of neutron-rich Kr isotopes

    CERN Document Server

    Delahaye, P; Blaum, K; Carrel, F; George, S; Herfurth, F; Herlert, A; Kellerbauer, A G; Kluge, H J; Lunney, D; Schweikhard, L; Yazidjian, C

    2006-01-01

    The atomic masses of the neutron-rich krypton isotopes 84,86-95Kr have been determined with the tandem Penning trap mass spectrometer ISOLTRAP with uncertainties ranging from 20 to 220 ppb. The masses of the short-lived isotopes 94Kr and 95Kr were measured for the first time. The masses of the radioactive nuclides 89Kr and 91Kr disagree by 4 and 6 standard deviations, respectively, from the present Atomic-Mass Evaluation database. The resulting modification of the mass surface with respect to the two-neutron separation energies as well as implications for mass models and stellar nucleosynthesis are discussed.

  19. Comparative Analysis of Mass Spectral Similarity Measures on Peak Alignment for Comprehensive Two-Dimensional Gas Chromatography Mass Spectrometry

    Science.gov (United States)

    2013-01-01

    Peak alignment is a critical procedure in mass spectrometry-based biomarker discovery in metabolomics. One of peak alignment approaches to comprehensive two-dimensional gas chromatography mass spectrometry (GC×GC-MS) data is peak matching-based alignment. A key to the peak matching-based alignment is the calculation of mass spectral similarity scores. Various mass spectral similarity measures have been developed mainly for compound identification, but the effect of these spectral similarity measures on the performance of peak matching-based alignment still remains unknown. Therefore, we selected five mass spectral similarity measures, cosine correlation, Pearson's correlation, Spearman's correlation, partial correlation, and part correlation, and examined their effects on peak alignment using two sets of experimental GC×GC-MS data. The results show that the spectral similarity measure does not affect the alignment accuracy significantly in analysis of data from less complex samples, while the partial correlation performs much better than other spectral similarity measures when analyzing experimental data acquired from complex biological samples. PMID:24151524

  20. Measurement of the W boson mass with the ATLAS detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00408270

    This thesis describes a measurement of the W boson mass with the ATLAS detector based on the data-set recorded by ATLAS in 2011 at a centre-of-mass energy of 7 TeV, and corresponding to 4.6 inverse femtobarn of integrated luminosity. Measurements are performed through template fits to the transverse momentum distributions of charged leptons and to transverse mass distributions of the W boson, in electron and muon decay modes in various kinematic categories. The individual measurements are found to be consistent and their combination leads to a value of \\begin{eqnarray} \

  1. ImageJ: A Free, Easy, and Reliable Method to Measure Leg Ulcers Using Digital Pictures.

    Science.gov (United States)

    Aragón-Sánchez, Javier; Quintana-Marrero, Yurena; Aragón-Hernández, Cristina; Hernández-Herero, María José

    2017-12-01

    Wound measurement to document the healing course of chronic leg ulcers has an important role in the management of these patients. Digital cameras in smartphones are readily available and easy to use, and taking pictures of wounds is becoming a routine in specialized departments. Analyzing digital pictures with appropriate software provides clinicians a quick, clean, and easy-to-use tool for measuring wound area. A set of 25 digital pictures of plain foot and leg ulcers was the basis of this study. Photographs were taken placing a ruler next to the wound in parallel with the healthy skin with the iPhone 6S (Apple Inc, Cupertino, CA), which has a camera of 12 megapixels using the flash. The digital photographs were visualized with ImageJ 1.45s freeware (National Institutes of Health, Rockville, MD; http://imagej.net/ImageJ ). Wound area measurement was carried out by 4 raters: head of the department, wound care nurse, physician, and medical student. We assessed intra- and interrater reliability using the interclass correlation coefficient. To determine intraobserver reliability, 2 of the raters repeated the measurement of the set 1 week after the first reading. The interrater model displayed an interclass correlation coefficient of 0.99 with 95% confidence interval of 0.999 to 1.000, showing excellent reliability. The intrarater model of both examiners showed excellent reliability. In conclusion, analyzing digital images of leg ulcers with ImageJ estimates wound area with excellent reliability. This method provides a free, rapid, and accurate way to measure wounds and could routinely be used to document wound healing in daily clinical practice.

  2. OBT measurement of vegetation by mass spectrometry and radiometry

    International Nuclear Information System (INIS)

    Tamari, T.; Kakiuchi, H.; Momoshima, N.; Sugihara, S.; Baglan, N.; Uda, T.

    2011-01-01

    We carried out OBT (organically bound tritium) measurement by two different methods those are radiometry and mass spectrometry and compared the applicability of these methods for environmental tritium analysis. The dried grass sample was used for the experiments. To eliminate the exchangeable OBT, the sample was washed with tritium free water before analysis. Three times washing reduced the tritium activity in the labile sites below the detectable level. In radiometry the sample was combusted to convert the OBT as well as other hydrogen isotopes to. water and tritium activity in the water was measured by liquid scintillation counting (LSC). In mass spectrometry, the sample was kept in a glass container and 3 He produced by tritium decay was measured by mass spectrometry. The results were in good agreement suggesting applicability of these methods for environmental tritium analysis. The mass spectrometry is more suitable for environmental tritium research because of a lower detection limit than that of the LSC. (authors)

  3. Overview of the JYFLTRAP mass measurements and high-precision ...

    Indian Academy of Sciences (India)

    nuclei, the mass difference can be determined with much higher precision than would normally be possible since for the mass doublets the systematic uncertainties become ..... The two-neutron separation energies in N = 60 indicate the. 338 ... Masses of zinc isotopes (Z = 30) were measured up to 80Zn, providing valuable.

  4. Reliability of pelvic floor measurements on three- and four-dimensional ultrasound during and after first pregnancy: implications for training.

    Science.gov (United States)

    van Veelen, G A; Schweitzer, K J; van der Vaart, C H

    2013-11-01

    To evaluate the reliability of measurements of the levator hiatus and levator-urethra gap (LUG) using three/four-dimensional (3D/4D) transperineal ultrasound in women during their first pregnancy and 6 months postpartum, and to assess the learning process for these measurements. An inexperienced observer was taught to perform measurements of the levator hiatus and LUG by an experienced observer. After training, 3D/4D ultrasound volume datasets of 40 women in the first trimester were analyzed by these two observers. Another training session then took place and both observers repeated the analyses of the same volume datasets. Finally, analyses of 40 volume datasets of the women 6 months postpartum were performed by both observers. Intra- and interobserver reliability were determined by intraclass correlation coefficients (ICC) with 95% CIs. For levator hiatal measurements, in the women during their first pregnancy the interobserver reliability was substantial to almost perfect after both the first and second training session (ICC, 0.62-0.83 and 0.71-0.89, respectively, for anteroposterior diameter, transverse diameter and area at rest, on contraction and on Valsalva) and the intraobserver reliability was substantial to almost perfect for both observers. For these measurements performed once the women had delivered, interobserver reliability was moderate to almost perfect. For LUG measurements performed during pregnancy, interobserver reliability was slight to moderate after the first training session (ICC, 0.14-0.54), but improved after the second training session (ICC, 0.38-0.71), and intraobserver reliability was moderate to substantial for the experienced observer and slight to moderate for the inexperienced observer. For these measurements performed when the women had delivered, interobserver reliability was fair to moderate. The levator hiatus and LUG can be measured reliably using 3D/4D ultrasound in primigravid and primiparous women. The technique to measure

  5. Design reliability engineering

    International Nuclear Information System (INIS)

    Buden, D.; Hunt, R.N.M.

    1989-01-01

    Improved design techniques are needed to achieve high reliability at minimum cost. This is especially true of space systems where lifetimes of many years without maintenance are needed and severe mass limitations exist. Reliability must be designed into these systems from the start. Techniques are now being explored to structure a formal design process that will be more complete and less expensive. The intent is to integrate the best features of design, reliability analysis, and expert systems to design highly reliable systems to meet stressing needs. Taken into account are the large uncertainties that exist in materials, design models, and fabrication techniques. Expert systems are a convenient method to integrate into the design process a complete definition of all elements that should be considered and an opportunity to integrate the design process with reliability, safety, test engineering, maintenance and operator training. 1 fig

  6. High-precision mass measurements for the rp-process at JYFLTRAP

    Directory of Open Access Journals (Sweden)

    Canete Laetitia

    2017-01-01

    Full Text Available The double Penning trap JYFLTRAP at the University of Jyväskylä has been successfully used to achieve high-precision mass measurements of nuclei involved in the rapid proton-capture (rp process. A precise mass measurement of 31Cl is essential to estimate the waiting point condition of 30S in the rp-process occurring in type I x-ray bursts (XRBs. The mass-excess of 31C1 measured at JYFLTRAP, -7034.7(3.4 keV, is 15 more precise than the value given in the Atomic Mass Evaluation 2012. The proton separation energy Sp determined from the new mass-excess value confirmed that 30S is a waiting point, with a lower-temperature limit of 0.44 GK. The mass of 52Co effects both 51Fe(p,γ52Co and 52Co(p,γ53Ni reactions. The mass-excess value measured, - 34 331.6(6.6 keV is 30 times more precise than the value given in AME2012. The Q values for the 51Fe(p,γ52Co and 52Co(p,γ53Ni reactions are now known with a high precision, 1418(11 keV and 2588(26 keV respectively. The results show that 52Co is more proton bound and 53Ni less proton bound than what was expected from the extrapolated value.

  7. Measuring Atmospheric Abundances and Rotation of a Brown Dwarf with a Measured Mass and Radius

    Science.gov (United States)

    Birkby, Jayne

    2015-08-01

    There are no cool brown dwarfs with both a well-characterized atmosphere and a measured mass and radius. LHS 6343, a brown dwarf transiting one member of an M+M binary in the Kepler field, provides the first opportunity to tie theoretical atmospheric models to the observed brown dwarf mass-radius diagram. We propose four half-nights of observations with NIRSPAO in 2015B to measure spectral features in LHS 6343 C by detecting the relative motions of absorption features during the system's orbit. In addition to abundances, we will directly measure the brown dwarf's projected rotational velocity and mass.

  8. Reliability measures for indexed semi-Markov chains applied to wind energy production

    International Nuclear Information System (INIS)

    D'Amico, Guglielmo; Petroni, Filippo; Prattico, Flavio

    2015-01-01

    The computation of the dependability measures is a crucial point in many engineering problems as well as in the planning and development of a wind farm. In this paper we address the issue of energy production by wind turbines by using an indexed semi-Markov chain as a model of wind speed. We present the mathematical model, the data and technical characteristics of a commercial wind turbine (Aircon HAWT-10kW). We show how to compute some of the main dependability measures such as reliability, availability and maintainability functions. We compare the results of the model with real energy production obtained from data available in the Lastem station (Italy) and sampled every 10 min. - Highlights: • Semi-Markov models. • Time series generation of wind speed. • Computation of availability, reliability and maintainability.

  9. Cyber Physical Systems for User Reliability Measurements in a Sharing Economy Environment.

    Science.gov (United States)

    Seo, Aria; Jeong, Junho; Kim, Yeichang

    2017-08-13

    As the sharing economic market grows, the number of users is also increasing but many problems arise in terms of reliability between providers and users in the processing of services. The existing methods provide shared economic systems that judge the reliability of the provider from the viewpoint of the user. In this paper, we have developed a system for establishing mutual trust between providers and users in a shared economic environment to solve existing problems. In order to implement a system that can measure and control users' situation in a shared economic environment, we analyzed the necessary factors in a cyber physical system (CPS). In addition, a user measurement system based on a CPS structure in a sharing economic environment is implemented through analysis of the factors to consider when constructing a CPS.

  10. Pneumothorax size measurements on digital chest radiographs: Intra- and inter- rater reliability.

    Science.gov (United States)

    Thelle, Andreas; Gjerdevik, Miriam; Grydeland, Thomas; Skorge, Trude D; Wentzel-Larsen, Tore; Bakke, Per S

    2015-10-01

    Detailed and reliable methods may be important for discussions on the importance of pneumothorax size in clinical decision-making. Rhea's method is widely used to estimate pneumothorax size in percent based on chest X-rays (CXRs) from three measure points. Choi's addendum is used for anterioposterior projections. The aim of this study was to examine the intrarater and interrater reliability of the Rhea and Choi method using digital CXR in the ward based PACS monitors. Three physicians examined a retrospective series of 80 digital CXRs showing pneumothorax, using Rhea and Choi's method, then repeated in a random order two weeks later. We used the analysis of variance technique by Eliasziw et al. to assess the intrarater and interrater reliability in altogether 480 estimations of pneumothorax size. Estimated pneumothorax sizes ranged between 5% and 100%. The intrarater reliability coefficient was 0.98 (95% one-sided lower-limit confidence interval C 0.96), and the interrater reliability coefficient was 0.95 (95% one-sided lower-limit confidence interval 0.93). This study has shown that the Rhea and Choi method for calculating pneumothorax size has high intrarater and interrater reliability. These results are valid across gender, side of pneumothorax and whether the patient is diagnosed with primary or secondary pneumothorax. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Different top-down approaches to estimate measurement uncertainty of whole blood tacrolimus mass concentration values.

    Science.gov (United States)

    Rigo-Bonnin, Raül; Blanco-Font, Aurora; Canalias, Francesca

    2018-05-08

    Values of mass concentration of tacrolimus in whole blood are commonly used by the clinicians for monitoring the status of a transplant patient and for checking whether the administered dose of tacrolimus is effective. So, clinical laboratories must provide results as accurately as possible. Measurement uncertainty can allow ensuring reliability of these results. The aim of this study was to estimate measurement uncertainty of whole blood mass concentration tacrolimus values obtained by UHPLC-MS/MS using two top-down approaches: the single laboratory validation approach and the proficiency testing approach. For the single laboratory validation approach, we estimated the uncertainties associated to the intermediate imprecision (using long-term internal quality control data) and the bias (utilizing a certified reference material). Next, we combined them together with the uncertainties related to the calibrators-assigned values to obtain a combined uncertainty for, finally, to calculate the expanded uncertainty. For the proficiency testing approach, the uncertainty was estimated in a similar way that the single laboratory validation approach but considering data from internal and external quality control schemes to estimate the uncertainty related to the bias. The estimated expanded uncertainty for single laboratory validation, proficiency testing using internal and external quality control schemes were 11.8%, 13.2%, and 13.0%, respectively. After performing the two top-down approaches, we observed that their uncertainty results were quite similar. This fact would confirm that either two approaches could be used to estimate the measurement uncertainty of whole blood mass concentration tacrolimus values in clinical laboratories. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Evaluating test-retest reliability in patient-reported outcome measures for older people: A systematic review.

    Science.gov (United States)

    Park, Myung Sook; Kang, Kyung Ja; Jang, Sun Joo; Lee, Joo Yun; Chang, Sun Ju

    2018-03-01

    This study aimed to evaluate the components of test-retest reliability including time interval, sample size, and statistical methods used in patient-reported outcome measures in older people and to provide suggestions on the methodology for calculating test-retest reliability for patient-reported outcomes in older people. This was a systematic literature review. MEDLINE, Embase, CINAHL, and PsycINFO were searched from January 1, 2000 to August 10, 2017 by an information specialist. This systematic review was guided by both the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist and the guideline for systematic review published by the National Evidence-based Healthcare Collaborating Agency in Korea. The methodological quality was assessed by the Consensus-based Standards for the selection of health Measurement Instruments checklist box B. Ninety-five out of 12,641 studies were selected for the analysis. The median time interval for test-retest reliability was 14days, and the ratio of sample size for test-retest reliability to the number of items in each measure ranged from 1:1 to 1:4. The most frequently used statistical methods for continuous scores was intraclass correlation coefficients (ICCs). Among the 63 studies that used ICCs, 21 studies presented models for ICC calculations and 30 studies reported 95% confidence intervals of the ICCs. Additional analyses using 17 studies that reported a strong ICC (>0.09) showed that the mean time interval was 12.88days and the mean ratio of the number of items to sample size was 1:5.37. When researchers plan to assess the test-retest reliability of patient-reported outcome measures for older people, they need to consider an adequate time interval of approximately 13days and the sample size of about 5 times the number of items. Particularly, statistical methods should not only be selected based on the types of scores of the patient-reported outcome measures, but should also be described clearly in

  13. Report of the working group on precision measurements. - Measurement of the W boson mass and width

    International Nuclear Information System (INIS)

    Brock, R.; Erler, J.; Kim, Y.-K.; Marciano, W.; Ashmanskas, W.; Baur, U.; Ellison, J.; Lancaster, M.; Nodulman, L.; Rha, J.; Waters, D.; Womersley, J.

    2000-01-01

    We discuss the prospects for measuring the W mass and width in Run II. The basic techniques used to measure M W are described and the statistical, theoretical and detector-related uncertainties are discussed in detail. Alternative methods of measuring the W mass at the Tevatron and the prospects for M W measurements at other colliders are also described

  14. Measurement of mass and isotopic fission yields for heavy fission products with the LOHENGRIN mass spectrometer

    International Nuclear Information System (INIS)

    Bail, A.

    2009-05-01

    In spite of the huge amount of fission yield data available in different libraries, more accurate values are still needed for nuclear energy applications and to improve our understanding of the fission process. Thus measurements of fission yields were performed at the mass spectrometer Lohengrin at the Institut Laue-Langevin in Grenoble, France. The mass separator Lohengrin is situated at the research reactor of the institute and permits the placement of an actinide layer in a high thermal neutron flux. It separates fragments according to their atomic mass, kinetic energy and ionic charge state by the action of magnetic and electric fields. Coupled to a high resolution ionization chamber the experiment was used to investigate the mass and isotopic yields of the light mass region. Almost all fission yields of isotopes from Th to Cf have been measured at Lohengrin with this method. To complete and improve the nuclear data libraries, these measurements have been extended in this work to the heavy mass region for the reactions 235 U(n th ,f), 239 Pu(n th ,f) and 241 Pu(n th ,f). For these higher masses an isotopic separation is no longer possible. So, a new method was undertaken with the reaction 239 Pu(n th ,f) to determine the isotopic yields by spectrometry. These experiments have allowed to reduce considerably the uncertainties. Moreover the ionic charge state and kinetic energy distributions were specifically studied and have shown, among others, nanosecond isomers for some masses. (author)

  15. Reliability and Validity of Computerized Force Platform Measures of Balance Function in Healthy Older Adults.

    Science.gov (United States)

    Harro, Cathy C; Garascia, Chelsea

    2018-01-10

    Postural control declines with aging and is an independent risk factor for falls in older adults. Objective examination of balance function is warranted to direct fall prevention strategies. Force platform (FP) systems provide quantitative measures of postural control and analysis of different aspects of balance. The purpose of this study was to examine the reliability and validity of FP measures in healthy older adults. This study enrolled 46 healthy elderly adults, mean age 67.67 (5.1) years, who had no history of falls. They were assessed on 3 standardized tests on the NeuroCom Equitest FP system: limits of stability (LOS), motor control test (MCT), and sensory organization test (SOT). The test battery was administered twice within a 10-day period for test-retest reliability; intraclass correlation coefficients (ICCs), standard error of measurement (SEM), and minimal detectable change based on a 95% confidence interval (MDC95) were calculated. FP measures were compared with criterion clinical balance (Mini-BESTest and Functional Gait Assessment) and gait (10-m walk and 6-minute walk) measures to examine concurrent validity using Pearson correlation coefficients. Multiple linear regression analysis examined whether age and activity level were associated with FP performance. The α level was set at P point excursion measures all demonstrated excellent test-retest reliability (ICC = 0.90, 0.85, and 0.77, respectively), whereas moderate to good reliability was found for SOT vestibular ratio score (ICC = 0.71). There was large variability in performance in this healthy elderly cohort, resulting in relatively large MDC95 for these measures, especially for the LOS test. Fair correlations were found between LOS end point excursion and clinical balance and gait measures (r = 0.31-0.49), and between MCT average latency and gait measures only (r = -0.32). No correlations were found between SOT measures and clinical balance and gait measures. Age was only marginally

  16. Isochronicity corrections for isochronous mass measurements at the HIRFL-CSRe

    International Nuclear Information System (INIS)

    Gao, Xiang; Yuan, You-Jin; Yang, Jian-cheng; Litvinov, S.; Wang, Meng; Litvinov, Y.; Zhang, Wei; Yin, Da-Yu; Shen, Guo-Dong; Chai, Wei-ping; Shi, Jian; Shang, Peng

    2014-01-01

    Isochronous Mass Spectrometry (IMS) is a unique experimental method for mass measurement experiments on short-lived nuclei. Mass measurements of 78 Kr projectile fragments were performed in HIRFL-CSRe at the Institute of Modern Physics (IMP), Chinese Academy of Sciences. The short-lived secondary beams were produced by bombarding a 15 mm thick beryllium-target in the Radioactive Ion Beam Line (RIBLL2) and were then injected into the CSRe storage ring. The masses of stored ions were measured by employing the IMS technique, which is based on the determination of the ion revolution times. A dedicated time-of-flight (TOF) detector is used for the latter purpose. However, the isochronicity, and thus the mass resolving power, depends on the momentum spread and the transverse emittance of the injected beams, Here, we present the first-order isochronicity optimization, the chromaticity and second-order isochronicity corrections through the modification of the quadrupole and sextupole field strengths. With the help of these corrections, the mass resolution of Δm/m=10 −6 can be achieved

  17. Isochronicity corrections for isochronous mass measurements at the HIRFL-CSRe

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Xiang [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Graduate University of Chinese Academy of Sciences, Beijing 100049 (China); Yuan, You-Jin; Yang, Jian-cheng [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Litvinov, S. [GSI, Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt (Germany); Wang, Meng [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Litvinov, Y. [GSI, Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt (Germany); Zhang, Wei; Yin, Da-Yu [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Shen, Guo-Dong [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Graduate University of Chinese Academy of Sciences, Beijing 100049 (China); Chai, Wei-ping; Shi, Jian [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Shang, Peng [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Graduate University of Chinese Academy of Sciences, Beijing 100049 (China)

    2014-11-01

    Isochronous Mass Spectrometry (IMS) is a unique experimental method for mass measurement experiments on short-lived nuclei. Mass measurements of {sup 78}Kr projectile fragments were performed in HIRFL-CSRe at the Institute of Modern Physics (IMP), Chinese Academy of Sciences. The short-lived secondary beams were produced by bombarding a 15 mm thick beryllium-target in the Radioactive Ion Beam Line (RIBLL2) and were then injected into the CSRe storage ring. The masses of stored ions were measured by employing the IMS technique, which is based on the determination of the ion revolution times. A dedicated time-of-flight (TOF) detector is used for the latter purpose. However, the isochronicity, and thus the mass resolving power, depends on the momentum spread and the transverse emittance of the injected beams, Here, we present the first-order isochronicity optimization, the chromaticity and second-order isochronicity corrections through the modification of the quadrupole and sextupole field strengths. With the help of these corrections, the mass resolution of Δm/m=10{sup −6} can be achieved.

  18. Study on highly reliable digital communication technology of reactor nuclear measuring equipment

    International Nuclear Information System (INIS)

    Gu Pengfei; Huang Xiaojin

    2007-01-01

    To meet the need of highly reliable of reactor nuclear measuring equipment, in allusion to the idiographic request of nuclear measuring equipment, the actual technical development and the application in industrial field, we design a kind of redundancy communication net based on PROFIBUS, and a kind of communication interface module based on redundancy PROFIBUS communication, which link the nuclear measuring equipment and PROFIBUS communication net, and also lay a foundation for advanced research. (authors)

  19. Reliability and validity in measurement of true humeral retroversion by a three-dimensional cylinder fitting method.

    Science.gov (United States)

    Saka, Masayuki; Yamauchi, Hiroki; Hoshi, Kenji; Yoshioka, Toru; Hamada, Hidetoshi; Gamada, Kazuyoshi

    2015-05-01

    Humeral retroversion is defined as the orientation of the humeral head relative to the distal humerus. Because none of the previous methods used to measure humeral retroversion strictly follow this definition, values obtained by these techniques vary and may be biased by morphologic variations of the humerus. The purpose of this study was 2-fold: to validate a method to define the axis of the distal humerus with a virtual cylinder and to establish the reliability of 3-dimensional (3D) measurement of humeral retroversion by this cylinder fitting method. Humeral retroversion in 14 baseball players (28 humeri) was measured by the 3D cylinder fitting method. The root mean square error was calculated to compare values obtained by a single tester and by 2 different testers using the embedded coordinate system. To establish the reliability, intraclass correlation coefficient (ICC) and precision (standard error of measurement [SEM]) were calculated. The root mean square errors for the humeral coordinate system were reliability and precision of the 3D measurement of retroversion yielded an intratester ICC of 0.99 (SEM, 1.0°) and intertester ICC of 0.96 (SEM, 2.8°). The error in measurements obtained by a distal humerus cylinder fitting method was small enough not to affect retroversion measurement. The 3D measurement of retroversion by this method provides excellent intratester and intertester reliability. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. Reliability and reference values of two clinical measurements of dynamic and static knee position in healthy children

    DEFF Research Database (Denmark)

    Ortqvist, Maria; Moström, Eva B; Roos, Ewa M.

    2011-01-01

    PURPOSE: The purposes of this study were to evaluate reliability of the Single-limb mini squat test (a dynamic measure of medio-lateral knee position) and the Quadriceps-angle (Q-angle) (a static measure of medio-lateral knee position), present paediatric reference values of the Q......-angle measurements was found. Reference values for the Q-angle (mean 13.5° (1.9)-15.3° (2.8)) varies with age and gender. No associations were found between dynamic and static measures. CONCLUSIONS: The Single-limb mini squat test showed a moderate reliability and the Q-angle showed a fair to moderate reliability......-angle, and evaluate the association between the tests. METHODS: Two hundred and forty-six healthy children (9-16 years) were included (intra/inter-rater reliability for Q-angle (n = 37/85) and for Single-limb mini squat test (n = 33/28)). Dynamic medio-lateral knee position was assessed by the Single-limb mini squat...

  1. New Methods for Top-Quark Mass Measurements at the LHC

    CERN Document Server

    Stieger, Benjamin

    2016-01-01

    Several recent new measurements of the top-quark mass that use alternative observables and reconstruction techniques are presented, performed by the ATLAS and CMS collaborations at the CERN LHC. Alternative observables can help provide insight by presenting different systematic sensitivities and by constraining prevailing systematic uncertainties of standard measurements, such as jet energy calibrations. Furthermore, the top-quark mass is extracted from theoretically well-defined observables, such as the inclusive production cross section for top quark pairs. Finally, the mass is measured in event topologies dominated by electroweak-mediated single top production by both experiments. The results of different techniques and production modes are found to be consistent with what is obtained in standard measurements.

  2. Reliability of widefield capillary microscopy to measure nailfold capillary density in systemic sclerosis.

    Science.gov (United States)

    Hudson, M; Masetto, A; Steele, R; Arthurs, E; Baron, M

    2010-01-01

    To determine intra- and inter-observer reliability of widefield microscopy to measure nailfold capillary density in patients with systemic sclerosis (SSc). Five SSc patients were examined with a STEMV-8 Zeiss biomicroscope with 50x magnification. The nailfold of the second, third, fourth and fifth fingers of both hands of each patient were photographed twice by each of two observers, once in the morning and again in the afternoon (total of 32 pictures). Two raters reviewed the photographs to produce capillary density readings. Intra- and inter-rater reliability of the readings were computed using intra-class correlations (ICC). Additional analyses were undertaken to determine the impact of other sources of variability in the data, namely patient, finger, technician and time. Intra-and inter-rater reliability were substantial (ICC 0.72-0.84) when raters were reading the same photographs or photographs taken at the same time of day. Agreement was only fair between morning and afternoon density readings (ICC 0.30-0.37). Patients, individual fingers and technician accounted for a large part of the variability in the data (combined variance component of 7.69 out of the total 12.23). The coefficient of variation of widefield microscopy was 24%. Although intra- and inter-rater reliability of nailfold capillary density measurements using widefield microscopy are good, proper standardisation of the conditions under which capillaroscopy is done and better imaging of nailfold capillary abnormalities should be considered if nailfold capillary density is to be used as an outcome measure in multi-centre clinical trials in SSc.

  3. Measurement of the Higgs boson mass with a linear e+e- collider

    International Nuclear Information System (INIS)

    Garcia-Abia, P.; Lohmann, W.; Raspereza, A.

    2005-05-01

    The potential of a linear e + e - collider operated at a centre-of-mass energy of 350 GeV is studied for the measurement of the Higgs boson mass. An integrated luminosity of 500 fb -1 is assumed. For Higgs boson masses of 120, 150 and 180 GeV the uncertainty on the Higgs boson mass measurement is estimated to be 40, 65 and 70 MeV, respectively. The effects of beam related systematics, namely a bias in the beam energy measurement, the beam energy spread and the luminosity spectrum due to beamstrahlung, on the precision of the Higgs boson mass measurement are investigated. In order to keep the systematic uncertainty on the Higgs boson mass well below the level of the statistical error, the beam energy measurement must be controlled with a relative precision better than 10 -4 . (orig.)

  4. A Systematic Review of Statistical Methods Used to Test for Reliability of Medical Instruments Measuring Continuous Variables

    Directory of Open Access Journals (Sweden)

    Rafdzah Zaki

    2013-06-01

    Full Text Available   Objective(s: Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice.   Materials and Methods: In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. Results: The Intra-class Correlation Coefficient (ICC is the most popular method with 25 (60% studies having used this method followed by the comparing means (8 or 19%. Out of 25 studies using the ICC, only 7 (28% reported the confidence intervals and types of ICC used. Most studies (71% also tested the agreement of instruments. Conclusion: This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  5. Contamination measurements with quadrupole mass spectrometer

    International Nuclear Information System (INIS)

    Bohatka, S.; Berecz, I.; Langer, G.

    1981-01-01

    A sensitive quadrupole mass spectrometer of our own construction was used for different purity measurements. The analysis of gases in operating rooms showed a 1 ppm-10 5 ppm concentration of narcotics and helped to develop an effective and cheap method for regenerating narcotic filters. We regularly control the gases used in radioactive pollution measurements by internal GM counters and in radiocarbon dating technique. Combustion products and the gases of a fermenter are investigated for industrial application. (orig.) [de

  6. Determining Reliability and Validity of the Persian Version of Software Usability Measurements Inventory (SUMI) Questionnaire

    OpenAIRE

    seyed abolfazl zakerian; Roya Azizi; Mehdi Rahgozar

    2013-01-01

    The term usability refers to a special index for success of an operating system. This study aimed to determine the reliability and validity of the Software Usability Measurements Inventory (SUMI) questionnaire as one of the valid and common questionnaires about usability evaluation. The back translation method was used to translate the questionnaire from English to Persian back to English. Moreover, repeatability or test-retest reliability was practically used to determine the reliability of ...

  7. Mass measurement on the rp-process waiting point {sup 72}Kr

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, D. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Kolhinen, V.S. [Jyvaeskylae Univ. (Finland); Audi, G. [CSNSM-IN2P3-Centre National de la Recherche Scientifique (CNRS), 91 - Orsay (FR)] [and others

    2004-06-01

    The mass of one of the three major waiting points in the astrophysical rp-process {sup 72}Kr was measured for the first time with the Penning trap mass spectrometer ISOLTRAP. The measurement yielded a relative mass uncertainty of {delta}m/m=1.2 x 10{sup -7} ({delta}m=8 keV). Other Kr isotopes, also needed for astrophysical calculations, were measured with more than one order of magnitude improved accuracy. We use the ISOLTRAP masses of{sup 72-74}Kr to reanalyze the role of the {sup 72}Kr waiting point in the rp-process during X-ray bursts. (orig.)

  8. Onsets of nuclear deformation from measurements with the Isoltrap mass spectrometer

    International Nuclear Information System (INIS)

    Naimi, S.

    2010-10-01

    Mass measurements provide important information concerning nuclear structure. This work presents results from the pioneering Penning trap spectrometer Isoltrap at CERN-Isolde. High-precision mass measurements of neutron-rich manganese ( 58 - 66 Mn) and krypton isotopes ( 96, 97 Kr) are presented, of which the 66 Mn and 96, 97 Kr masses are measured for the first time. In particular, the mass of 97 Kr was measured using the preparation trap and required the definition of a new fit function. In the case of the manganese isotopes, the N=40 shell closure is addressed. The two-neutron-separation energies calculated from the new masses show no shell closure at N=40 but give an estimation of the proton-neutron interaction (around 0.5 MeV) responsible for the increase of collectivity and nuclear deformation in this mass region. The new krypton masses show behavior in sharp contrast with heavier neighbors where sudden and intense deformation is present, interpreted as the establishment of a nuclear quantum shape/phase transition critical-point boundary. The new masses confirm findings from nuclear mean-square charge-radius measurements up to N=60 but are at variance with conclusions from recent gamma-ray spectroscopy. Another part of this work was the design of new decay spectroscopy system behind the Isoltrap mass spectrometer. The beam purity achievable with Isoltrap will allow decay studies with γ and β detection coupled to a tape-station. This system has been mounted and commissioned with the radioactive beam 80 Rb. (author)

  9. Mass and lifetime measurements of exotic nuclei in storage rings

    International Nuclear Information System (INIS)

    Franzke, B.; Geissel, H.; Muenzenberg, G.

    2007-11-01

    Mass and lifetime measurements lead to the discovery and understanding of basic properties of matter. The isotopic nature of the chemical elements, nuclear binding, and the location and strength of nuclear shells are the most outstanding examples leading to the development of the first nuclear models. More recent are the discoveries of new structures of nuclides far from the valley of stability. A new generation of direct mass measurements which allows the exploration of extended areas of the nuclear mass surface with high accuracy has been opened up with the combination of the Experimental Storage Ring ESR and the FRragment Separator FRS at GSI Darmstadt. In-flight separated nuclei are stored in the ring. Their masses are directly determined from the revolution frequency. Dependent on the half-life two complementary methods are applied. Schottky Mass Spectrometry SMS relies on the measurement of the revolution frequency of electron cooled stored ions. The cooling time determines the lower half-life limit to the order of seconds. For Isochronous Mass Spectrometry IMS the ring is operated in an isochronous ion-optical mode. The revolution frequency of the individual ions coasting in the ring is measured using a time-of-flight method. Nuclides with lifetimes down to microseconds become accessible. With SMS masses of several hundreds nuclides have been measured simultaneously with an accuracy in the 2 x 10 -7 -range. This high accuracy and the ability to study large areas of the mass surface are ideal tools to discover new nuclear structure properties and to guide improvements for theoretical mass models. In addition, nuclear half-lives of stored bare and highly-charged ions have been measured. This new experimental development is a significant progress since nuclear decay characteristics are mostly known for neutral atoms. For bare and highly-charged ions new nuclear decay modes become possible, such as bound-state beta decay. Dramatic changes in the nuclear lifetime

  10. Proposal on electron anti-neutrino mass measurement at INS

    International Nuclear Information System (INIS)

    Ohshima, Takayoshi.

    1981-03-01

    Some comment on the proposed experiment, namely the measurement of electron anti-neutrino mass, is described. Various experiments with the measurement of β-ray from tritium have been reported. The precise measurement of the shape of the Kurie plot is required in this kind of experiment. The present experiment aimed at more accurate determination of neutrino mass than any other previous ones. An important point of the present experiment is to reduce the background due to the β-ray from evaporating tritium. The source candidates have low evaporation rate. A double focus √2π air core spectrometer is employed for the measurement of β-ray. The spectrometer was improved to meet the present purpose. The accumulated event rate was expected to be about 10 times higher than Russian experiment. The estimated energy resolution was about 30 eV. The neutrino mass with less than 10 eV accuracy will be obtained. (Kato, T.)

  11. Ultra Reliable Closed Loop Life Support for Long Space Missions

    Science.gov (United States)

    Jones, Harry W.; Ewert, Michael K.

    2010-01-01

    Spacecraft human life support systems can achieve ultra reliability by providing sufficient spares to replace all failed components. The additional mass of spares for ultra reliability is approximately equal to the original system mass, provided that the original system reliability is not too low. Acceptable reliability can be achieved for the Space Shuttle and Space Station by preventive maintenance and by replacing failed units. However, on-demand maintenance and repair requires a logistics supply chain in place to provide the needed spares. In contrast, a Mars or other long space mission must take along all the needed spares, since resupply is not possible. Long missions must achieve ultra reliability, a very low failure rate per hour, since they will take years rather than weeks and cannot be cut short if a failure occurs. Also, distant missions have a much higher mass launch cost per kilogram than near-Earth missions. Achieving ultra reliable spacecraft life support systems with acceptable mass will require a well-planned and extensive development effort. Analysis must determine the reliability requirement and allocate it to subsystems and components. Ultra reliability requires reducing the intrinsic failure causes, providing spares to replace failed components and having "graceful" failure modes. Technologies, components, and materials must be selected and designed for high reliability. Long duration testing is needed to confirm very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The system must be designed, developed, integrated, and tested with system reliability in mind. Maintenance and reparability of failed units must not add to the probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass should start soon since it must be a long term effort.

  12. The Top Quark Mass, Systematic Limitations, and my Tracker-Driven Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Garberson, Ford [Univ. of California, Santa Barbara, CA (United States)

    2008-08-01

    Top quark mass measurements have achieved an unexpected level of accu- racy in the last several years. This accuracy is only possible because of a new procedure that calibrates away the dominant jet energy uncertainty of past mea- surements. In this thesis I present some studies illustrating my suspicions that this procedure is leading them to claim overly optimistic results. Additionally, I present three measurements of the top quark mass that will be almost entirely independent of jet energies, and will thus serve as important cross checks of the standard measurements once enough statistics have been collected. I perform my measurements of the top quark mass in the lepton plus jets channel with approximately 1.9 fb-1 of integrated luminosity collected with the CDF detector using quantities with minimal dependence on the jet energies. One measurement exploits the transverse decay length of b-tagged jets to determine a top quark mass of 166.9+9.5 (stat)±2.9 (syst) GeV/c2, and another the transverse momentum of electrons and muons from W decays to determine a top quark mass of 173.5+8.8 - (stat) ± 3.8 (syst) GeV/c2. I combine these quantities in a vi third, simultaneous mass measurement to determine a top quark mass of 170.7 ± 6.3 (stat) ± 2.6 (syst) GeV/c2.

  13. Application-Driven Reliability Measures and Evaluation Tool for Fault-Tolerant Real-Time Systems

    National Research Council Canada - National Science Library

    Krishna, C

    2001-01-01

    .... The measure combines graphic-theoretic concepts in evaluating the underlying reliability of the network and other means to evaluate the ability of the network to support interprocessor traffic...

  14. Measurement methods to assess diastasis of the rectus abdominis muscle (DRAM): A systematic review of their measurement properties and meta-analytic reliability generalisation.

    Science.gov (United States)

    van de Water, A T M; Benjamin, D R

    2016-02-01

    Systematic literature review. Diastasis of the rectus abdominis muscle (DRAM) has been linked with low back pain, abdominal and pelvic dysfunction. Measurement is used to either screen or to monitor DRAM width. Determining which methods are suitable for screening and monitoring DRAM is of clinical value. To identify the best methods to screen for DRAM presence and monitor DRAM width. AMED, Embase, Medline, PubMed and CINAHL databases were searched for measurement property studies of DRAM measurement methods. Population characteristics, measurement methods/procedures and measurement information were extracted from included studies. Quality of all studies was evaluated using 'quality rating criteria'. When possible, reliability generalisation was conducted to provide combined reliability estimations. Thirteen studies evaluated measurement properties of the 'finger width'-method, tape measure, calipers, ultrasound, CT and MRI. Ultrasound was most evaluated. Methodological quality of these studies varied widely. Pearson's correlations of r = 0.66-0.79 were found between calipers and ultrasound measurements. Calipers and ultrasound had Intraclass Correlation Coefficients (ICC) of 0.78-0.97 for test-retest, inter- and intra-rater reliability. The 'finger width'-method had weighted Kappa's of 0.73-0.77 for test-retest reliability, but moderate agreement (63%; weighted Kappa = 0.53) between raters. Comparing calipers and ultrasound, low measurement error was found (above the umbilicus), and the methods had good agreement (83%; weighted Kappa = 0.66) for discriminative purposes. The available information support ultrasound and calipers as adequate methods to assess DRAM. For other methods limited measurement information of low to moderate quality is available and further evaluation of their measurement properties is required. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Reliability and reproducibility analysis of the Cobb angle and assessing sagittal plane by computer-assisted and manual measurement tools.

    Science.gov (United States)

    Wu, Weifei; Liang, Jie; Du, Yuanli; Tan, Xiaoyi; Xiang, Xuanping; Wang, Wanhong; Ru, Neng; Le, Jinbo

    2014-02-06

    Although many studies on reliability and reproducibility of measurement have been performed on coronal Cobb angle, few results about reliability and reproducibility are reported on sagittal alignment measurement including the pelvis. We usually use SurgimapSpine software to measure the Cobb angle in our studies; however, there are no reports till date on its reliability and reproducible measurements. Sixty-eight standard standing posteroanterior whole-spine radiographs were reviewed. Three examiners carried out the measurements independently under the settings of manual measurement on X-ray radiographies and SurgimapSpine software on the computer. Parameters measured included pelvic incidence, sacral slope, pelvic tilt, Lumbar lordosis (LL), thoracic kyphosis, and coronal Cobb angle. SPSS 16.0 software was used for statistical analyses. The means, standard deviations, intraclass and interclass correlation coefficient (ICC), and 95% confidence intervals (CI) were calculated. There was no notable difference between the two tools (P = 0.21) for the coronal Cobb angle. In the sagittal plane parameters, the ICC of intraobserver reliability for the manual measures varied from 0.65 (T2-T5 angle) to 0.95 (LL angle). Further, for SurgimapSpine tool, the ICC ranged from 0.75 to 0.98. No significant difference in intraobserver reliability was found between the two measurements (P > 0.05). As for the interobserver reliability, measurements with SurgimapSpine tool had better ICC (0.71 to 0.98 vs 0.59 to 0.96) and Pearson's coefficient (0.76 to 0.99 vs 0.60 to 0.97). The reliability of SurgimapSpine measures was significantly higher in all parameters except for the coronal Cobb angle where the difference was not significant (P > 0.05). Although the differences between the two methods are very small, the results of this study indicate that the SurgimapSpine measurement is an equivalent measuring tool to the traditional manual in coronal Cobb angle, but is advantageous in spino

  16. Measurement of the top quark mass in the dilepton channel

    International Nuclear Information System (INIS)

    Grinstein, S.; Mostafa, M.; Piegaia, R.; Alves, G.A.; Carvalho, W.; Maciel, A.K.; Motta, H. da; Oliveira, E.; Santoro, A.; Lima, J.G.; Oguri, V.; Gomez, B.; Hoeneisen, B.; Mooney, P.; Negret, J.P.; Ducros, Y.; Beri, S.B.; Bhatnagar, V.; Kohli, J.M.; Singh, J.B.; Shivpuri, R.K.; Acharya, B.S.; Banerjee, S.; Dugad, S.R.; Gupta, A.; Krishnaswamy, M.R.; Mondal, N.K.; Narasimham, V.S.; Parua, N.; Shankar, H.C.; Park, Y.M.; Choi, S.; Kim, S.K.; Castilla-Valdez, H.; Gonzalez Solis, J.L.; Hernandez-Montoya, R.; Magana-Mendoza, L.; Sanchez-Hernandez, A.; Pawlik, B.; Gavrilov, V.; Gershtein, Y.; Kuleshov, S.; Belyaev, A.; Dudko, L.V.; Ermolov, P.; Karmanov, D.; Leflat, A.; Manankov, V.; Merkin, M.; Shabalina, E.; Abramov, V.; Babintsev, V.V.; Bezzubov, V.A.; Bojko, N.I.; Burtovoi, V.S.; Chekulaev, S.V.; Denisov, S.P.; Dyshkant, A.; Eroshin, O.V.; Evdokimov, V.N.; Galyaev, A.N.; Goncharov, P.I.; Gurzhiev, S.N.; Kostritskiy, A.V.; Kozelov, A.V.; Kozlovsky, E.A.; Mayorov, A.A.; Babukhadia, L.; Davis, K.; Fein, D.; Forden, G.E.; Guida, J.A.; James, E.; Johns, K.; Nang, F.; Narayanan, A.; Rutherfoord, J.; Shupe, M.; Aihara, H.; Barberis, E.; Chen, L.

    1999-01-01

    We report a measurement of the top quark mass using six candidate events for the process p bar p→t bar t+X→l + νbl - bar ν bar b+X, observed in the D0 experiment at the Fermilab p bar p collider. Using maximum likelihood fits to the dynamics of the decays, we measure a mass for the top quark of m t =168.4±12.3(stat)±3.6(syst) Gev. We combine this result with our previous measurement in the t bar t→l+jets channel to obtain m t =172.1±7.1 GeV as the best value of the mass of the top quark measured by D0. copyright 1999 The American Physical Society

  17. Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.

    Directory of Open Access Journals (Sweden)

    Xiangjun Chen

    Full Text Available PURPOSE: To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK eyes and compare the results between these two groups. METHODS: Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs were calculated. Univariate analysis of covariance (ANCOVA was used to compare measured parameters between virgin and post-PRK eyes. RESULTS: The intraocular pressure (IOP, central corneal thickness (CCT and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90 in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88. The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05 and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05 in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05 and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05. CONCLUSIONS: CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.

  18. Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength.

    Science.gov (United States)

    Vannebo, Katrine Tranaas; Iversen, Vegard Moe; Fimland, Marius Steiro; Mork, Paul Jarle

    2018-03-02

    There is a lack of test-retest reliability studies of measurements of cervical muscle strength, taking into account gender and possible learning effects. To investigate test-retest reliability of measurement of maximal isometric cervical muscle strength by handheld dynamometry. Thirty women (age 20-58 years) and 28 men (age 20-60 years) participated in the study. Maximal isometric strength (neck flexion, neck extension, and right/left lateral flexion) was measured on three separate days at least five days apart by one evaluator. Intra-rater consistency tended to improve from day 1-2 measurements to day 2-3 measurements in both women and men. In women, the intra-class correlation coefficients (ICC) for day 2 to day 3 measurements were 0.91 (95% confidence interval [CI], 0.82-0.95) for neck flexion, 0.88 (95% CI, 0.76-0.94) for neck extension, 0.84 (95% CI, 0.68-0.92) for right lateral flexion, and 0.89 (95% CI, 0.78-0.95) for left lateral flexion. The corresponding ICCs among men were 0.86 (95% CI, 0.72-0.93) for neck flexion, 0.93 (95% CI, 0.85-0.97) for neck extension, 0.82 (95% CI, 0.65-0.91) for right lateral flexion and 0.73 (95% CI, 0.50-0.87) for left lateral flexion. This study describes a reliable and easy-to-administer test for assessing maximal isometric cervical muscle strength.

  19. Aviation Fuel System Reliability and Fail-Safety Analysis. Promising Alternative Ways for Improving the Fuel System Reliability

    Directory of Open Access Journals (Sweden)

    I. S. Shumilov

    2017-01-01

    Full Text Available The paper deals with design requirements for an aviation fuel system (AFS, AFS basic design requirements, reliability, and design precautions to avoid AFS failure. Compares the reliability and fail-safety of AFS and aircraft hydraulic system (AHS, considers the promising alternative ways to raise reliability of fuel systems, as well as elaborates recommendations to improve reliability of the pipeline system components and pipeline systems, in general, based on the selection of design solutions.It is extremely advisable to design the AFS and AHS in accordance with Aviation Regulations АП25 and Accident Prevention Guidelines, ICAO (International Civil Aviation Association, which will reduce risk of emergency situations, and in some cases even avoid heavy disasters.ATS and AHS designs should be based on the uniform principles to ensure the highest reliability and safety. However, currently, this principle is not enough kept, and AFS looses in reliability and fail-safety as compared with AHS. When there are the examined failures (single and their combinations the guidelines to ensure the AFS efficiency should be the same as those of norm-adopted in the Regulations АП25 for AHS. This will significantly increase reliability and fail-safety of the fuel systems and aircraft flights, in general, despite a slight increase in AFS mass.The proposed improvements through the use of components redundancy of the fuel system will greatly raise reliability of the fuel system of a passenger aircraft, which will, without serious consequences for the flight, withstand up to 2 failures, its reliability and fail-safety design will be similar to those of the AHS, however, above improvement measures will lead to a slightly increasing total mass of the fuel system.It is advisable to set a second pump on the engine in parallel with the first one. It will run in case the first one fails for some reasons. The second pump, like the first pump, can be driven from the

  20. Intra-rater reliability of hallux flexor strength measures using the Nintendo Wii Balance Board.

    Science.gov (United States)

    Quek, June; Treleaven, Julia; Brauer, Sandra G; O'Leary, Shaun; Clark, Ross A

    2015-01-01

    The purpose of this study was to investigate the intra-rater reliability of a new method in combination with the Nintendo Wii Balance Board (NWBB) to measure the strength of hallux flexor muscle. Thirty healthy individuals (age: 34.9 ± 12.9 years, height: 170.4 ± 10.5 cm, weight: 69.3 ± 15.3 kg, female = 15) participated. Repeated testing was completed within 7 days. Participants performed strength testing in sitting using a wooden platform in combination with the NWBB. This new method was set up to selectively recruit an intrinsic muscle of the foot, specifically the flexor hallucis brevis muscle. Statistical analysis was performed using intra-class coefficients and ordinary least product analysis. To estimate measurement error, standard error of measurement (SEM), minimal detectable change (MDC) and percentage error were calculated. Results indicate excellent intra-rater reliability (ICC = 0.982, CI = 0.96-0.99) with an absence of systematic bias. SEM, MDC and percentage error value were 0.5, 1.4 and 12 % respectively. This study demonstrates that a new method in combination with the NWBB application is reliable to measure hallux flexor strength and has potential to be used for future research and clinical application.

  1. Measurement of the top mass at the LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00000243; The ATLAS collaboration

    2015-01-01

    The top quark is the most massive fundamental particle ever observed. As such, it plays a particular role in the theories of elementary constituents of matter. The motivation for a precise measurement of the top quark mass ensues from this role. The ATLAS and CMS experiments at the LHC have taken part in this effort and achieve precisions below the GeV, using data collected during the years 2011 and 2012, at a centre-of-mass energy $\\sqrt{s}$ of 7 TeV and 8 TeV respectively. This document reviews the measurements performed by the two collaborations at the time of writing.

  2. Quantitative measurement of hypertrophic scar: intrarater reliability, sensitivity, and specificity.

    Science.gov (United States)

    Nedelec, Bernadette; Correa, José A; Rachelska, Grazyna; Armour, Alexis; LaSalle, Léo

    2008-01-01

    The comparison of scar evaluation over time requires measurement tools with acceptable intrarater reliability and the ability to discriminate skin characteristics of interest. The objective of this study was to evaluate the intrarater reliability and sensitivity and specificity of the Cutometer, the Mexameter, and the DermaScan C relative to the modified Vancouver Scar Scale (mVSS) in patient-matched normal skin, normal scar (donor sites), and hypertrophic scar (HSc). A single investigator evaluated four tissue types (severe HSc, less severe HSc, donor site, and normal skin) in 30 burn survivors with all four measurement tools. The intraclass correlation coefficient (ICC) for the Cutometer was acceptable (> or =0.75) for the maximum deformation measure for the donor site and normal skin (>0.78) but was below the acceptable range for the HSc sites and all other parameters. The ICC for the Mexameter erythema (>0.75) and melanin index (>0.89) and the DermaScan C total thickness measurement (>0.82) were acceptable for all sites. The ICC for the total of the height, pliability, and vascularity subscales of the mVSS was acceptable (0.81) for normal scar but below the acceptable range for the scar sites. The DermaScan C was clearly able to discriminate HSc from normal scar and normal skin based on the total thickness measure. The Cutometer was less discriminating but was still able to discriminate HSc from normal scar and normal skin. The Mexameter erythema index was not a good discriminator of HSc and normal scar. Receiver operating characteristic curves were generated to establish the best cutoff point for the DermaScan C total thickness and the Cutometer maximum deformation, which were 2.034 and 0.387 mm, respectively. This study showed that although the Cutometer, the DermaScan C, and the Mexameter have measurement properties that make them attractive substitutes for the mVSS, caution must be used when interpreting results since the Cutometer has a ceiling effect when

  3. Mass measurements on radioactive isotopes using the ISOLTRAP spectrometer

    CERN Document Server

    Dilling, J; Kluge, H J; Kohl, A; Lamour, E; Marx, G; Schwarz, S C; Bollen, G; Kellerbauer, A G; Moore, R B; Henry, S

    2000-01-01

    ISOLTRAP is a Penning trap mass spectrometer installed at the on line isotope separator ISOLDE at CERN. Direct measurements of the masses of short lived radio isotopes are performed using the existing triple trap system. This consists of three electromagnetic traps in tandem: a Paul trap to accumulate and bunch the 60 keV dc beam, a Penning trap for cooling and isobar separation, and a precision Penning trap for the determination of the masses by cyclotron resonance. Measurements of masses of unknown mercury isotopes and in the vicinity of doubly magic /sup 208/Pb are presented, all with an accuracy of delta m/m approximately=1*10/sup -7/. Developments to replace the Paul trap by a radiofrequency quadrupole ion guide system to increase the collection efficiency are presently under way and the status is presented. (10 refs).

  4. Measurements of the top quark mass using the ATLAS detector at the LHC

    CERN Document Server

    Pinamonti, Michele; The ATLAS collaboration

    2018-01-01

    The latest measurements of the top quark mass using the ATLAS experiment are presented. A measurement based on a multi-dimensional template fit that can constrain the uncertainties on the energy measurements of jets is presented and combined with measurements using dilepton and all-hadronic events. In addition an analysis of the top quark mass using leptonic kinematic variables is discussed. The measurement uses a novel technique to measure the top quark mass with minimal dependence on hadronic jets. A measurement of the top quark width and the measurements that use precision theoretical QCD calculations for both inclusive ttbar production and ttbar production with an additional jet to extract the top quark mass in the pole-mass scheme are also presented.

  5. High precision measurement of the {eta} meson mass at COSY-ANKE

    Energy Technology Data Exchange (ETDEWEB)

    Goslawski, Paul

    2013-07-01

    Previous measurements of the {eta} meson mass performed at different experimental facilities resulted in very precise data but differ by up to more than eight standard deviations, i.e., 0.5 MeV/c. Interestingly, the difference seems to be dependent on the measuring method: two missing mass experiments, which produce the {eta} meson in the {sup 3}He{eta} final state, deviate from the recent invariant mass ones. In order to clarify this ambiguous situation a high precision mass measurement was realised at the COSY-ANKE facility. Therefore, a set of deuteron laboratory beam momenta and their associated {sup 3}He centre-of-mass momenta was measured in the dp{yields}{sup 3}HeX reaction near the {eta} production threshold. The {eta} meson was identified by the missing mass peak, whereas its mass was extracted by fixing the production threshold. The individual beam momenta were determined with a relative precision of 3 x 10{sup -5} for values just above 3 GeV/c by using a polarised deuteron beam and inducing an artificial depolarising spin resonance occurring at a well-defined frequency. The final state momenta in the two-body reaction dp{yields}{sup 3}He{eta} were investigated in detail by studying the size of the {sup 3}He momentum sphere with the forward detection system of the ANKE spectrometer. Final alignment and momentum calibration of the spectrometer was achieved by a comprehensive study of the {sup 3}He final state momenta as a function of the centre-of-mass angles, taking advantage of the full geometrical acceptance. The value obtained for the mass at COSY-ANKE m{sub {eta}}=(547.873{+-}0.005{sub stat.}{+-}0.027{sub syst.}) MeV/c{sup 2} is therefore worldwide the most precise one. This mass value is contrary to earlier missing mass experiments but it is consistent and competitive with recent invariant mass measurements, in which the meson was detected through its decay products.

  6. [Reliability study in the measurement of the cusp inclination angle of a chairside digital model].

    Science.gov (United States)

    Xinggang, Liu; Xiaoxian, Chen

    2018-02-01

    This study aims to evaluate the reliability of the software Picpick in the measurement of the cusp inclination angle of a digital model. Twenty-one trimmed models were used as experimental objects. The chairside digital impression was then used for the acquisition of 3D digital models, and the software Picpick was employed for the measurement of the cusp inclination of these models. The measurements were repeated three times, and the results were compared with a gold standard, which was a manually measured experimental model cusp angle. The intraclass correlation coefficient (ICC) was calculated. The paired t test value of the two measurement methods was 0.91. The ICCs between the two measurement methods and three repeated measurements were greater than 0.9. The digital model achieved a smaller coefficient of variation (9.9%). The software Picpick is reliable in measuring the cusp inclination of a digital model.

  7. Reliability of perceived neighbourhood conditions and the effects of measurement error on self-rated health across urban and rural neighbourhoods.

    Science.gov (United States)

    Pruitt, Sandi L; Jeffe, Donna B; Yan, Yan; Schootman, Mario

    2012-04-01

    Limited psychometric research has examined the reliability of self-reported measures of neighbourhood conditions, the effect of measurement error on associations between neighbourhood conditions and health, and potential differences in the reliabilities between neighbourhood strata (urban vs rural and low vs high poverty). We assessed overall and stratified reliability of self-reported perceived neighbourhood conditions using five scales (social and physical disorder, social control, social cohesion, fear) and four single items (multidimensional neighbouring). We also assessed measurement error-corrected associations of these conditions with self-rated health. Using random-digit dialling, 367 women without breast cancer (matched controls from a larger study) were interviewed twice, 2-3 weeks apart. Test-retest (intraclass correlation coefficients (ICC)/weighted κ) and internal consistency reliability (Cronbach's α) were assessed. Differences in reliability across neighbourhood strata were tested using bootstrap methods. Regression calibration corrected estimates for measurement error. All measures demonstrated satisfactory internal consistency (α ≥ 0.70) and either moderate (ICC/κ=0.41-0.60) or substantial (ICC/κ=0.61-0.80) test-retest reliability in the full sample. Internal consistency did not differ by neighbourhood strata. Test-retest reliability was significantly lower among rural (vs urban) residents for two scales (social control, physical disorder) and two multidimensional neighbouring items; test-retest reliability was higher for physical disorder and lower for one multidimensional neighbouring item among the high (vs low) poverty strata. After measurement error correction, the magnitude of associations between neighbourhood conditions and self-rated health were larger, particularly in the rural population. Research is needed to develop and test reliable measures of perceived neighbourhood conditions relevant to the health of rural populations.

  8. Quantitative outcome measures for systemic sclerosis-related Microangiopathy - Reliability of image acquisition in Nailfold Capillaroscopy.

    Science.gov (United States)

    Dinsdale, Graham; Moore, Tonia; O'Leary, Neil; Berks, Michael; Roberts, Christopher; Manning, Joanne; Allen, John; Anderson, Marina; Cutolo, Maurizio; Hesselstrand, Roger; Howell, Kevin; Pizzorni, Carmen; Smith, Vanessa; Sulli, Alberto; Wildt, Marie; Taylor, Christopher; Murray, Andrea; Herrick, Ariane L

    2017-09-01

    Nailfold capillaroscopic parameters hold increasing promise as outcome measures for clinical trials in systemic sclerosis (SSc). Their inclusion as outcomes would often naturally require capillaroscopy images to be captured at several time points during any one study. Our objective was to assess repeatability of image acquisition (which has been little studied), as well as of measurement. 41 patients (26 with SSc, 15 with primary Raynaud's phenomenon) and 10 healthy controls returned for repeat high-magnification (300×) videocapillaroscopy mosaic imaging of 10 digits one week after initial imaging (as part of a larger study of reliability). Images were assessed in a random order by an expert blinded observer and 4 outcome measures extracted: (1) overall image grade and then (where possible) distal vessel locations were marked, allowing (2) vessel density (across the whole nailfold) to be calculated (3) apex width measurement and (4) giant vessel count. Intra-rater, intra-visit and intra-rater inter-visit (baseline vs. 1week) reliability were examined in 475 and 392 images respectively. A linear, mixed-effects model was used to estimate variance components, from which intra-class correlation coefficients (ICCs) were determined. Intra-visit and inter-visit reliability estimates (ICCs) were (respectively): overall image grade, 0.97 and 0.90; vessel density, 0.92 and 0.65; mean vessel width, 0.91 and 0.79; presence of giant capillary, 0.68 and 0.56. These estimates were conditional on each parameter being measurable. Within-operator image analysis and acquisition are reproducible. Quantitative nailfold capillaroscopy, at least with a single observer, provides reliable outcome measures for clinical studies including randomised controlled trials. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Satellite measurements of aerosol mass and transport

    Energy Technology Data Exchange (ETDEWEB)

    Fraser, R.S.; Kaufman, Y.J.; Mahoney, R.L.

    1984-01-01

    The aerosol optical thickness over land is derived from satellite measurements of the radiance of scattered sunlight. These data are used to estimate the columnar mass density of particulate sulfur on a day with a large amount of sulfur. The horizontal transport of the particulate sulfur is calculated using wing vectors measured with rawins. 33 references, 7 figures, 1 table.

  10. Developing Ultra Reliable Life Support for the Moon and Mars

    Science.gov (United States)

    Jones, Harry W.

    2009-01-01

    Recycling life support systems can achieve ultra reliability by using spares to replace failed components. The added mass for spares is approximately equal to the original system mass, provided the original system reliability is not very low. Acceptable reliability can be achieved for the space shuttle and space station by preventive maintenance and by replacing failed units, However, this maintenance and repair depends on a logistics supply chain that provides the needed spares. The Mars mission must take all the needed spares at launch. The Mars mission also must achieve ultra reliability, a very low failure rate per hour, since it requires years rather than weeks and cannot be cut short if a failure occurs. Also, the Mars mission has a much higher mass launch cost per kilogram than shuttle or station. Achieving ultra reliable space life support with acceptable mass will require a well-planned and extensive development effort. Analysis must define the reliability requirement and allocate it to subsystems and components. Technologies, components, and materials must be designed and selected for high reliability. Extensive testing is needed to ascertain very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The systems must be designed, produced, integrated, and tested without impairing system reliability. Maintenance and failed unit replacement should not introduce any additional probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass must start soon if it is to produce timely results for the moon and Mars.

  11. MEASURING TINY MASS ACCRETION RATES ONTO YOUNG BROWN DWARFS

    International Nuclear Information System (INIS)

    Herczeg, Gregory J.; Cruz, Kelle L.; Hillenbrand, Lynne A.

    2009-01-01

    We present low-resolution Keck I/LRIS spectra spanning from 3200 to 9000 A of nine young brown dwarfs and three low-mass stars in the TW Hya Association and in Upper Sco. The optical spectral types of the brown dwarfs range from M5.5 to M8.75, though two have near-IR spectral types of early L dwarfs. We report new accretion rates derived from excess Balmer continuum emission for the low-mass stars TW Hya and Hen 3-600A and the brown dwarfs 2MASS J12073347-3932540, UScoCTIO 128, SSSPM J1102-3431, USco J160606.29-233513.3, DENIS-P J160603.9-205644, and Oph J162225-240515B, and upper limits on accretion for the low-mass star Hen 3-600B and the brown dwarfs UScoCTIO 112, Oph J162225-240515A, and USco J160723.82-221102.0. For the six brown dwarfs in our sample that are faintest at short wavelengths, the accretion luminosity or upper limit is measurable only when the image is binned over large wavelength intervals. This method extends our sensitivity to accretion rate down to ∼10 -13 M sun yr -1 for brown dwarfs. Since the ability to measure an accretion rate from excess Balmer continuum emission depends on the contrast between excess continuum emission and the underlying photosphere, for objects with earlier spectral types the upper limit on accretion rate is much higher. Absolute uncertainties in our accretion rate measurements of ∼3-5 include uncertainty in accretion models, brown dwarf masses, and distance. The accretion rate of 2 x 10 -12 M sun yr -1 onto 2MASS J12073347-3932540 is within 15% of two previous measurements, despite large changes in the Hα flux.

  12. System Reliability Engineering

    International Nuclear Information System (INIS)

    Lim, Tae Jin

    2005-02-01

    This book tells of reliability engineering, which includes quality and reliability, reliability data, importance of reliability engineering, reliability and measure, the poisson process like goodness of fit test and the poisson arrival model, reliability estimation like exponential distribution, reliability of systems, availability, preventive maintenance such as replacement policies, minimal repair policy, shock models, spares, group maintenance and periodic inspection, analysis of common cause failure, and analysis model of repair effect.

  13. A New Top Mass Measurement in The Dilepton Channel

    Energy Technology Data Exchange (ETDEWEB)

    Trovato, Marco; /INFN, Pisa /Pisa U.

    2008-01-01

    The top quark discovery completed the present picture of the fundamental constituents of the nature. Since then, the Collider Detector at Fermilab and D0 Collaborations have been spending great efforts to measure its properties better. About 30 times larger than the second heaviest quark, the mass of the top has been measured with increased statistic and more and more sophisticated techniques in order to reduce as much as possible its uncertainty. This is because the top is expected to play a fundamental role in the Standard Model. The value of its mass sets boundaries on the mass of the unobserved Higgs boson, and perhaps more appealing, studies of its properties might lead to the discovery of new physics.

  14. GAE detection for mass measurement for D-T ratio control

    International Nuclear Information System (INIS)

    Lister, J.B.; Villard, L.; Ridder, G. de

    1997-09-01

    This report includes two papers by the authors Lister, Villard and de Ridder: 1) Measurement of the effective plasma ion mass in large tokamaks using Global Alfven Eigenmodes, 2) GAE detection for mass measurement for plasma density control. The second paper represents the final report of JET article 14 contract 950104. figs., tabs., refs

  15. Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity

    Directory of Open Access Journals (Sweden)

    Mohammad Al-Amri

    2018-02-01

    Full Text Available The aim of this study was to investigate the reliability and concurrent validity of a commercially available Xsens MVN BIOMECH inertial-sensor-based motion capture system during clinically relevant functional activities. A clinician with no prior experience of motion capture technologies and an experienced clinical movement scientist each assessed 26 healthy participants within each of two sessions using a camera-based motion capture system and the MVN BIOMECH system. Participants performed overground walking, squatting, and jumping. Sessions were separated by 4 ± 3 days. Reliability was evaluated using intraclass correlation coefficient and standard error of measurement, and validity was evaluated using the coefficient of multiple correlation and the linear fit method. Day-to-day reliability was generally fair-to-excellent in all three planes for hip, knee, and ankle joint angles in all three tasks. Within-day (between-rater reliability was fair-to-excellent in all three planes during walking and squatting, and poor-to-high during jumping. Validity was excellent in the sagittal plane for hip, knee, and ankle joint angles in all three tasks and acceptable in frontal and transverse planes in squat and jump activity across joints. Our results suggest that the MVN BIOMECH system can be used by a clinician to quantify lower-limb joint angles in clinically relevant movements.

  16. The reliability and validity of fatigue measures during short-duration maximal-intensity intermittent cycling.

    Science.gov (United States)

    Glaister, Mark; Stone, Michael H; Stewart, Andrew M; Hughes, Michael; Moir, Gavin L

    2004-08-01

    The purpose of the present study was to assess the reliability and validity of fatigue measures, as derived from 4 separate formulae, during tests of repeat sprint ability. On separate days over a 3-week period, 2 groups of 7 recreationally active men completed 6 trials of 1 of 2 maximal (20 x 5 seconds) intermittent cycling tests with contrasting recovery periods (10 or 30 seconds). All trials were conducted on a friction-braked cycle ergometer, and fatigue scores were derived from measures of mean power output for each sprint. Apart from formula 1, which calculated fatigue from the percentage difference in mean power output between the first and last sprint, all remaining formulae produced fatigue scores that showed a reasonably good level of test-retest reliability in both intermittent test protocols (intraclass correlation range: 0.78-0.86; 95% likely range of true values: 0.54-0.97). Although between-protocol differences in the magnitude of the fatigue scores suggested good construct validity, within-protocol differences highlighted limitations with each formula. Overall, the results support the use of the percentage decrement score as the most valid and reliable measure of fatigue during brief maximal intermittent work.

  17. A NEW MEASUREMENT OF THE W BOSON MASS FROM CDF

    CERN Multimedia

    Ashutosh Kotwal

    CDF has measured the W boson mass using approx. 200pb-1 of data collected at  s = 1.96 TeV. The preliminary result mW = 80.413 ± 0.034(stat) ± 0.034(syst) GeV supports and strengthens the hypothesis of a light Higgs boson, based on the global electroweak fit in the standard model framework. The total measurement uncertainty of 48 MeV makes this result the most precise single measurement of the W boson mass to date. The mass of the W boson is a very interesting quantity. Experimentally, it can be measured precisely because of the two-body decay of the W boson into a charged lepton and a neutrino. Theoretically, it receives self-energy corrections due to vacuum fluctuations involving virtual particles. Thus the W boson mass probes the particle spectrum in nature, including those particles that have yet to be observed directly. The hypothetical particle of most immediate interest is the Higgs boson, representing the quantum of the Higgs field that spontaneously acquires a vacuu...

  18. Intracellular water exchange for measuring the dry mass, water mass and changes in chemical composition of living cells.

    Directory of Open Access Journals (Sweden)

    Francisco Feijó Delgado

    Full Text Available We present a method for direct non-optical quantification of dry mass, dry density and water mass of single living cells in suspension. Dry mass and dry density are obtained simultaneously by measuring a cell's buoyant mass sequentially in an H2O-based fluid and a D2O-based fluid. Rapid exchange of intracellular H2O for D2O renders the cell's water content neutrally buoyant in both measurements, and thus the paired measurements yield the mass and density of the cell's dry material alone. Utilizing this same property of rapid water exchange, we also demonstrate the quantification of intracellular water mass. In a population of E. coli, we paired these measurements to estimate the percent dry weight by mass and volume. We then focused on cellular dry density - the average density of all cellular biomolecules, weighted by their relative abundances. Given that densities vary across biomolecule types (RNA, DNA, protein, we investigated whether we could detect changes in biomolecular composition in bacteria, fungi, and mammalian cells. In E. coli, and S. cerevisiae, dry density increases from stationary to exponential phase, consistent with previously known increases in the RNA/protein ratio from up-regulated ribosome production. For mammalian cells, changes in growth conditions cause substantial shifts in dry density, suggesting concurrent changes in the protein, nucleic acid and lipid content of the cell.

  19. Reliability and Validity of an Internet-based Questionnaire Measuring Lifetime Physical Activity

    OpenAIRE

    De Vera, Mary A.; Ratzlaff, Charles; Doerfling, Paul; Kopec, Jacek

    2010-01-01

    Lifetime exposure to physical activity is an important construct for evaluating associations between physical activity and disease outcomes, given the long induction periods in many chronic diseases. The authors' objective in this study was to evaluate the measurement properties of the Lifetime Physical Activity Questionnaire (L-PAQ), a novel Internet-based, self-administered instrument measuring lifetime physical activity, among Canadian men and women in 2005–2006. Reliability was examined u...

  20. Assessing the Reliability of Curriculum-Based Measurement: An Application of Latent Growth Modeling

    Science.gov (United States)

    Yeo, Seungsoo; Kim, Dong-Il; Branum-Martin, Lee; Wayman, Miya Miura; Espin, Christine A.

    2012-01-01

    The purpose of this study was to demonstrate the use of Latent Growth Modeling (LGM) as a method for estimating reliability of Curriculum-Based Measurement (CBM) progress-monitoring data. The LGM approach permits the error associated with each measure to differ at each time point, thus providing an alternative method for examining of the…

  1. A precision measurement of the mass of the top quark

    International Nuclear Information System (INIS)

    Abazov, V.M.

    2004-01-01

    The standard model of particle physics contains parameters -- such as particle masses -- whose origins are still unknown and which cannot be predicted, but whose values are constrained through their interactions. In particular, the masses of the top quark (M t ) and W boson (M W ) constrain the mass of the long-hypothesized, but thus far not observed, Higgs boson. A precise measurement of M t can therefore indicate where to look for the Higgs, and indeed whether the hypothesis of a standard model Higgs is consistent with experimental data. As top quarks are produced in pairs and decay in only about 10 -24 s into various final states, reconstructing their masses from their decay products is very challenging. Here we report a technique that extracts more information from each top-quark event and yields a greatly improved precision (of +- 5.3 GeV/c 2 ) when compared to previous measurements. When our new result is combined with our published measurement in a complementary decay mode and with the only other measurements available, the new world average for M t becomes 178.0 +- 4.3 GeV/c 2 . As a result, the most likely Higgs mass increases from the experimentally excluded value of 96 to 117 GeV/c 2 , which is beyond current experimental sensitivity. The upper limit on the Higgs mass at the 95% confidence level is raised from 219 to 251 GeV/c 2

  2. Reliability, precision, and gender differences in knee internal/external rotation proprioception measurements.

    Science.gov (United States)

    Nagai, Takashi; Sell, Timothy C; Abt, John P; Lephart, Scott M

    2012-11-01

    To develop and assess the reliability and precision of knee internal/external rotation (IR/ER) threshold to detect passive motion (TTDPM) and determine if gender differences exist. Test-retest for the reliability/precision and cross-sectional for gender comparisons. University neuromuscular and human performance research laboratory. Ten subjects for the reliability and precision aim. Twenty subjects (10 males and 10 females) for gender comparisons. All TTDPM tests were performed using a multi-mode dynamometer. Subjects performed TTDPM at two knee positions (near IR or ER end-range). Intraclass correlation coefficient (ICC (3,k)) and standard error of measurement (SEM) were used to evaluate the reliability and precision. Independent t-tests were used to compare genders. TTDPM toward IR and ER at two knee positions. Intrasession and intersession reliability and precision were good (ICC=0.68-0.86; SEM=0.22°-0.37°). Females had significantly diminished TTDPM toward IR at IR-test position (males: 0.77°±0.14°, females: 1.18°±0.46°, p=0.021) and TTDPM toward IR at the ER-test position (males: 0.87°±0.13°, females: 1.36°±0.58°, p=0.026). No other significant gender differences were found (p>0.05). The current IR/ER TTDPM methods are reliable and accurate for the test-retest or cross-section research design. Gender differences were found toward IR where the ACL acts as the secondary restraint. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Accelerator mass spectrometry for measurement of long-lived radioisotopes.

    Science.gov (United States)

    Elmore, D; Phillips, F M

    1987-05-01

    Particle accelerators, such as those built for research in nuclear physics, can also be used together with magnetic and electrostatic mass analyzers to measure rare isotopes at very low abundance ratios. All molecular ions can be eliminated when accelerated to energies of millions of electron volts. Some atomic isobars can be eliminated with the use of negative ions; others can be separated at high energies by measuring their rate of energy loss in a detector. The long-lived radioisotopes (10)Be, (14)C,(26)A1, 36Cl, and (129)1 can now be measured in small natural samples having isotopic abundances in the range 10(-12) to 10(- 5) and as few as 10(5) atoms. In the past few years, research applications of accelerator mass spectrometry have been concentrated in the earth sciences (climatology, cosmochemistry, environmental chemistry, geochronology, glaciology, hydrology, igneous petrogenesis, minerals exploration, sedimentology, and volcanology), in anthropology and archeology (radiocarbon dating), and in physics (searches for exotic particles and measurement of halflives). In addition, accelerator mass spectrometry may become an important tool for the materials and biological sciences.

  4. Reliability of length measurements collected by community nurses and health volunteers in rural growth monitoring and promotion services.

    Science.gov (United States)

    Laar, Matilda E; Marquis, Grace S; Lartey, Anna; Gray-Donald, Katherine

    2018-02-17

    Length measurements are important in growth, monitoring and promotion (GMP) for the surveillance of a child's weight-for-length and length-for-age. These two indices provide an indication of a child's risk of becoming wasted or stunted, and are more informative about a child's growth than the widely used weight-for-age index (underweight). Although the introduction of length measurements in GMP is recommended by the World Health Organization, concerns about the reliability of length measurements collected in rural outreach settings have been expressed by stakeholders. Our aim was to describe the reliability and challenges associated with community health personnel measuring length for rural outreach GMP activities. Two reliability studies (A and B), using 10 children less than 24 months each, were conducted in the GMP services of a rural district in Ghana. Fifteen nurses and 15 health volunteers (HV) with no prior experience in length measurements were trained. Intra- and inter-observer technical error of measurement (TEM), average bias from expert anthropometrist, and coefficient of reliability (R) of length measurements were assessed and compared across sessions. Observations and interviews were used to understand the ability and experiences of health personnel with measuring length at outreach GMP. Inter-observer TEM was larger than intra-observer TEM for both nurses and HV at both sessions and was unacceptably (compared to error standards) high in both groups at both time points. Average biases from expert's measurements were within acceptable limits, however, both groups tended to underestimate length measurements. The R for lengths collected by nurses (92.3%) was higher at session B compared to that of HV (87.5%). Length measurements taken by nurses and HV, and those taken by an experienced anthropometrist at GMP sessions were of moderate agreement (kappa = 0.53, p reliability of length measurements improved after two refresher trainings for nurses but

  5. Reduction of determinate errors in mass bias-corrected isotope ratios measured using a multi-collector plasma mass spectrometer

    International Nuclear Information System (INIS)

    Doherty, W.

    2015-01-01

    A nebulizer-centric instrument response function model of the plasma mass spectrometer was combined with a signal drift model, and the result was used to identify the causes of the non-spectroscopic determinate errors remaining in mass bias-corrected Pb isotope ratios (Tl as internal standard) measured using a multi-collector plasma mass spectrometer. Model calculations, confirmed by measurement, show that the detectable time-dependent errors are a result of the combined effect of signal drift and differences in the coordinates of the Pb and Tl response function maxima (horizontal offset effect). If there are no horizontal offsets, then the mass bias-corrected isotope ratios are approximately constant in time. In the absence of signal drift, the response surface curvature and horizontal offset effects are responsible for proportional errors in the mass bias-corrected isotope ratios. The proportional errors will be different for different analyte isotope ratios and different at every instrument operating point. Consequently, mass bias coefficients calculated using different isotope ratios are not necessarily equal. The error analysis based on the combined model provides strong justification for recommending a three step correction procedure (mass bias correction, drift correction and a proportional error correction, in that order) for isotope ratio measurements using a multi-collector plasma mass spectrometer

  6. Determination of iodine to compliment mass spectrometric measurements

    International Nuclear Information System (INIS)

    Hohorst, F.A.

    1994-11-01

    The dose of iodine-129 to facility personnel and the general public as a result of past, present, and future activities at DOE sites is of continuing interest, WINCO received about 160 samples annually in a variety of natural matrices, including snow, milk, thyroid tissue, and sagebrush, in which iodine-129 is determined in order to evaluate this dose, Currently, total iodine and the isotopic ratio of iodine-127 to iodine-129 are determined by mass spectrometry. These two measurements determine the concentration of iodine-129 in each sample, These measurements require at least 16 h of mass spectrometer operator time for each sample. A variety of methods are available which concentrate and determine small quantities of iodine. Although useful, these approaches would increase both time and cost. The objective of this effort was to determine total iodine by an alternative method in order to decrease the load on mass spectrometry by 25 to 50%. The preparation of each sample for mass spectrometric analysis involves a common step--collection of iodide on an ion exchange bed. This was the focal point of the effort since the results would be applicable to all samples

  7. (U) An Analytic Study of Piezoelectric Ejecta Mass Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Tregillis, Ian Lee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-16

    We consider the piezoelectric measurement of the areal mass of an ejecta cloud, for the specific case where ejecta are created by a single shock at the free surface and fly ballistically through vacuum to the sensor. To do so, we define time- and velocity-dependent ejecta “areal mass functions” at the source and sensor in terms of typically unknown distribution functions for the ejecta particles. Next, we derive an equation governing the relationship between the areal mass function at the source (which resides in the rest frame of the free surface) and at the sensor (which resides in the laboratory frame). We also derive expressions for the analytic (“true”) accumulated ejecta mass at the sensor and the measured (“inferred”) value obtained via the standard method for analyzing piezoelectric voltage traces. This approach enables us to derive an exact expression for the error imposed upon a piezoelectric ejecta mass measurement (in a perfect system) by the assumption of instantaneous creation. We verify that when the ejecta are created instantaneously (i.e., when the time dependence is a delta function), the piezoelectric inference method exactly reproduces the correct result. When creation is not instantaneous, the standard piezo analysis will always overestimate the true mass. However, the error is generally quite small (less than several percent) for most reasonable velocity and time dependences. In some cases, errors exceeding 10-15% may require velocity distributions or ejecta production timescales inconsistent with experimental observations. These results are demonstrated rigorously with numerous analytic test problems.

  8. Reliability, precision, and measurement in the context of data from ability tests, surveys, and assessments

    International Nuclear Information System (INIS)

    Fisher, W P Jr; Elbaum, B; Coulter, A

    2010-01-01

    Reliability coefficients indicate the proportion of total variance attributable to differences among measures separated along a quantitative continuum by a testing, survey, or assessment instrument. Reliability is usually considered to be influenced by both the internal consistency of a data set and the number of items, though textbooks and research papers rarely evaluate the extent to which these factors independently affect the data in question. Probabilistic formulations of the requirements for unidimensional measurement separate consistency from error by modelling individual response processes instead of group-level variation. The utility of this separation is illustrated via analyses of small sets of simulated data, and of subsets of data from a 78-item survey of over 2,500 parents of children with disabilities. Measurement reliability ultimately concerns the structural invariance specified in models requiring sufficient statistics, parameter separation, unidimensionality, and other qualities that historically have made quantification simple, practical, and convenient for end users. The paper concludes with suggestions for a research program aimed at focusing measurement research more on the calibration and wide dissemination of tools applicable to individuals, and less on the statistical study of inter-variable relations in large data sets.

  9. Measurement of collective dynamical mass of Dirac fermions in graphene.

    Science.gov (United States)

    Yoon, Hosang; Forsythe, Carlos; Wang, Lei; Tombros, Nikolaos; Watanabe, Kenji; Taniguchi, Takashi; Hone, James; Kim, Philip; Ham, Donhee

    2014-08-01

    Individual electrons in graphene behave as massless quasiparticles. Unexpectedly, it is inferred from plasmonic investigations that electrons in graphene must exhibit a non-zero mass when collectively excited. The inertial acceleration of the electron collective mass is essential to explain the behaviour of plasmons in this material, and may be directly measured by accelerating it with a time-varying voltage and quantifying the phase delay of the resulting current. This voltage-current phase relation would manifest as a kinetic inductance, representing the reluctance of the collective mass to accelerate. However, at optical (infrared) frequencies, phase measurements of current are generally difficult, and, at microwave frequencies, the inertial phase delay has been buried under electron scattering. Therefore, to date, the collective mass in graphene has defied unequivocal measurement. Here, we directly and precisely measure the kinetic inductance, and therefore the collective mass, by combining device engineering that reduces electron scattering and sensitive microwave phase measurements. Specifically, the encapsulation of graphene between hexagonal boron nitride layers, one-dimensional edge contacts and a proximate top gate configured as microwave ground together enable the inertial phase delay to be resolved from the electron scattering. Beside its fundamental importance, the kinetic inductance is found to be orders of magnitude larger than the magnetic inductance, which may be utilized to miniaturize radiofrequency integrated circuits. Moreover, its bias dependency heralds a solid-state voltage-controlled inductor to complement the prevalent voltage-controlled capacitor.

  10. Mercury mass measurement in fluorescent lamps via neutron activation analysis

    International Nuclear Information System (INIS)

    Viererbl, L.; Vinš, M.; Lahodová, Z.; Fuksa, A.; Kučera, J.; Koleška, M.; Voljanskij, A.

    2015-01-01

    Mercury is an essential component of fluorescent lamps. Not all fluorescent lamps are recycled, resulting in contamination of the environment with toxic mercury, making measurement of the mercury mass used in fluorescent lamps important. Mercury mass measurement of lamps via instrumental neutron activation analysis (NAA) was tested under various conditions in the LVR-15 research reactor. Fluorescent lamps were irradiated in different positions in vertical irradiation channels and a horizontal channel in neutron fields with total fluence rates from 3×10 8 cm −2 s −1 to 10 14 cm −2 s −1 . The 202 Hg(n,γ) 203 Hg nuclear reaction was used for mercury mass evaluation. Activities of 203 Hg and others induced radionuclides were measured via gamma spectrometry with an HPGe detector at various times after irradiation. Standards containing an Hg 2 Cl 2 compound were used to determine mercury mass. Problems arise from the presence of elements with a large effective cross section in luminescent material (europium, antimony and gadolinium) and glass (boron). The paper describes optimization of the NAA procedure in the LVR-15 research reactor with particular attention to influence of neutron self-absorption in fluorescent lamps. - Highlights: • Mercury is an essential component of fluorescent lamps. • Fluorescent lamps were irradiated in neutron fields in research reactor. • 203 Hg induced radionuclide activity was measured using gamma spectrometry. • Mercury mass in fluorescent lamps can be measured by neutron activation analysis.

  11. The reliability of measuring pain distribution and location using body pain diagrams in patients with acute whiplash-associated disorders.

    Science.gov (United States)

    Southerst, Danielle; Stupar, Maja; Côté, Pierre; Mior, Silvano; Stern, Paula

    2013-09-01

    The objective of this study was to measure the interexaminer reliability of scoring pain distribution using paper and electronic body pain diagrams in patients with acute whiplash-associated disorder and to assess the intermethod reliability of measuring pain distribution and location using paper and electronic diagrams. We conducted an interexaminer reliability study on 80 participants recruited from a randomized controlled trial on the conservative management of acute grade I/II whiplash-associated disorder. Participants were assessed for inclusion/exclusion criteria by an experienced clinician. As part of the baseline assessment, participants independently completed paper and electronic pain diagrams. Diagrams were scored independently by 2 examiners using the body region method. Interexaminer and intermethod reliability was computed using intraclass correlation coefficients (ICCs) for pain distribution and κ coefficient for pain location. We used Bland-Altman plots to compute limits of agreement. The interexaminer reliability was ICC = 0.925 for paper and ICC = 0.997 for the electronic body pain diagram. The intermethod reliability for measuring pain distribution ranged from ICC = 0.63 to ICC = 0.93. For pain location, the intermethod reliability varied from κ = 0.23 (posterior neck) to κ = 0.90 (right side of the face). We found good to excellent interexaminer reliability for scoring 2 versions of the body pain diagram. Pain distribution and pain location were reliably and consistently measured on body pain diagrams using paper and electronic methods; therefore, clinicians and researchers may choose either medium when using body pain diagrams. Copyright © 2013 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  12. Mass measurements with the CIME cyclotron at GANIL

    International Nuclear Information System (INIS)

    Hornillos, M B Gomez; Chartier, M; Mittig, W; Blank, B; Chautard, F; Demonchy, C E; Gillibert, A; Jacquot, B; Jurado, B; Lecesne, N; Lepine-Szily, A; Orr, N A; Roussel-Chomaz, P; Savajols, H; Villari, A C C

    2005-01-01

    A new direct technique using the CIME cyclotron as a high-resolution mass spectrometer is being developed in order to measure the masses of exotic nuclei. Tests have been performed to check the feasibility of the method with a mixed beam of stable ions extracted from the SPIRAL ion source and injected into the CIME cyclotron. Preliminary results obtained with this new technique are presented and discussed

  13. Reliability of Composite Dichotomous Measurements

    Czech Academy of Sciences Publication Activity Database

    Martinková, Patrícia; Zvára, Karel

    2010-01-01

    Roč. 6, č. 2 (2010), s. 103-109 ISSN 1801-5603 R&D Projects: GA MŠk(CZ) 1M06014 Institutional research plan: CEZ:AV0Z10300504 Keywords : reliability * binary data * logistic regression * Cronbach alpha * Rasch model * myocardial perfusion diagnosis Subject RIV: BB - Applied Statistics, Operational Research http://www.ejbi.cz/articles/201012/65/1.html

  14. Neutron activation and mass spectrometric measurement of /sup 129/I

    International Nuclear Information System (INIS)

    Strebin, R.S. Jr.; Brauer, F.P.; Kaye, J.H.; Rapids, M.S.; Stoffels, J.J.

    1987-11-01

    An integrated procedure has been developed for measurement of /sup 129/I by neutron activation analysis and mass spectrometry. An iodine isolation procedure previously used for neutron activation has been modified to provide separated iodine suitable for mass spectrometric measurement as well. Agreement between both methods has been achieved within error limits. The measurement limit by each method is about 10/sup 7/ atoms (2 fg) of /sup 129/I. 13 refs,. 4 figs., 1 tab

  15. Sensitivity to mental effort and test-retest reliability of heart rate variability measures in healthy seniors.

    Science.gov (United States)

    Mukherjee, Shalini; Yadav, Rajeev; Yung, Iris; Zajdel, Daniel P; Oken, Barry S

    2011-10-01

    To determine (1) whether heart rate variability (HRV) was a sensitive and reliable measure in mental effort tasks carried out by healthy seniors and (2) whether non-linear approaches to HRV analysis, in addition to traditional time and frequency domain approaches were useful to study such effects. Forty healthy seniors performed two visual working memory tasks requiring different levels of mental effort, while ECG was recorded. They underwent the same tasks and recordings 2 weeks later. Traditional and 13 non-linear indices of HRV including Poincaré, entropy and detrended fluctuation analysis (DFA) were determined. Time domain, especially mean R-R interval (RRI), frequency domain and, among non-linear parameters - Poincaré and DFA were the most reliable indices. Mean RRI, time domain and Poincaré were also the most sensitive to different mental effort task loads and had the largest effect size. Overall, linear measures were the most sensitive and reliable indices to mental effort. In non-linear measures, Poincaré was the most reliable and sensitive, suggesting possible usefulness as an independent marker in cognitive function tasks in healthy seniors. A large number of HRV parameters was both reliable as well as sensitive indices of mental effort, although the simple linear methods were the most sensitive. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  16. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    International Nuclear Information System (INIS)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders; Andersson, Anna; Biglarnia, Ali-Reza

    2012-01-01

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume

  17. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders [Uppsala Univ., Dept. of Radiology, Oncology and Radiation Science, Section of Radiology, Uppsala (Sweden)], E-mail: eva.lundqvist.8954@student.uu.se; Andersson, Anna; Biglarnia, Ali-Reza [Dept. of Surgical Sciences, Section of Transplantation Surgery, Uppsala Univ. Hospital, Uppsala (Sweden)

    2012-11-15

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume.

  18. Measurement of the W boson mass with the ATLAS detector

    CERN Document Server

    Balli, Fabrice; The ATLAS collaboration

    2017-01-01

    A precise measurement of the mass of the W boson mass represents an important milestone to test the overall consistency of the Standard Model. Since the discovery of a Higgs Boson, the W boson mass is predicted to 7 MeV precision, while the world average of all measurements is 15 MeV, making the improved measurement an important goal. The ATLAS experiment at the LHC represents an ideal laboratory for such a precise measurement. Large samples of many millions of leptonic decays of W and Z bosons were collected with efficient single lepton triggers in the 7 TeV data set corresponding to an integrated luminosity of 4.6/fb. With these samples the detector and physics modelling has been studied in great detail to enable a systematic uncertainty on the measurement that approaches the statistical power of the data of 7 MeV per decay channel as far as possible.

  19. Reliability of three-dimensional sonographic measurements in early pregnancy using virtual reality

    NARCIS (Netherlands)

    C.M. Verwoerd-Dikkeboom (Christine); A.H.J. Koning (Anton); W.C.J. Hop (Wim); M. Rousian (Melek); P.J. van der Spek (Peter); N. Exalto (Niek); R.P.M. Steegers-Theunissen (Régine)

    2008-01-01

    textabstractObjective: To establish the reliability of three-dimensional (3D) ultrasound measurements in early pregnancy using a virtual reality system (the Barco I-Space). Methods: The study included 28 pregnancies with gestational ages ranging from 6 to 14 (median, 10) weeks. 3D volumes were

  20. Improving mass measurement accuracy in mass spectrometry based proteomics by combining open source tools for chromatographic alignment and internal calibration.

    Science.gov (United States)

    Palmblad, Magnus; van der Burgt, Yuri E M; Dalebout, Hans; Derks, Rico J E; Schoenmaker, Bart; Deelder, André M

    2009-05-02

    Accurate mass determination enhances peptide identification in mass spectrometry based proteomics. We here describe the combination of two previously published open source software tools to improve mass measurement accuracy in Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS). The first program, msalign, aligns one MS/MS dataset with one FTICRMS dataset. The second software, recal2, uses peptides identified from the MS/MS data for automated internal calibration of the FTICR spectra, resulting in sub-ppm mass measurement errors.

  1. Mass measurement of cooled neutron-deficient bismuth projectile fragments with time-resolved Schottky mass spectrometry at the FRS-ESR facility

    Energy Technology Data Exchange (ETDEWEB)

    Litvinov, Yu.A.; Geissel, H. [Giessen Univ. (Germany); Radon, T. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (DE)] [and others

    2005-06-01

    Masses of 582 neutron-deficient nuclides (30{<=}Z{<=}85) were measured with time-resolved Schottky mass spectrometry at the FRS-ESR facility at GSI, 117 were used for calibration. The masses of 71 nuclides were obtained for the first time. A typical mass accuracy of 30 {mu}u was achieved. These data have entered the latest atomic mass evaluation. The mass determination of about 140 additional nuclides was possible via known energies (Q-values) of {alpha}-, {beta}-, or proton decays. The obtained results are compared with the results of other measurements. (orig.)

  2. Accuracy and reliability of three-dimensional surface reconstruction measurement

    International Nuclear Information System (INIS)

    Mizukami, Chikashi; Yamamoto, Etsuo; Ohmura, Masaki; Oiki, Hiroyuki; Tsuji, Jun; Muneta, Yuki; Tanabe, Makito; Hakuba, Nobuhiro; Azemoto, Syougo.

    1993-01-01

    We are using a new three-dimensional (3-D) surface reconstruction system to measure the temporal bones. This system offers the advantage of observation of the external aperture of the vestibular aqueduct and the porus acusticus internus in living subjects. However, its accuracy has not been confirmed. To investigate the accuracy of this new system, we measured the length of an in situ ceramic ossicular replacement prosthesis (CORP) of known length of 6.0 mm using 3-D surface reconstruction, conventional plain X-ray and polytomography. The CORP was scanned in the axial, sagittal and oblique directions. The mean measured length obtained with the 3-D surface reconstruction images was 5.94±0.21 on vertical scans, 5.91±0.27 on horizontal scans, and 6.01±0.25 on oblique scans. There were no significant differences among the measured lengths obtained in the three directions. Therefore, this 3-D surface reconstruction measurement system is considered to be reliable. Conversely, the mean measured length obtained by plain X-ray was 7.98±0.20, and by polytomography it was 7.94±0.23. These conventional methods have the inherent disadvantage of magnification of size which consequently requires correction. (author)

  3. Two old ways to measure the electron-neutrino mass

    CERN Document Server

    De Rújula, A

    2013-01-01

    Three decades ago, the measurement of the electron neutrino mass in atomic electron capture (EC) experiments was scrutinized in its two variants: single EC and neutrino-less double EC. For certain isotopes an atomic resonance enormously enhances the expected decay rates. The favoured technique, based on calorimeters as opposed to spectrometers, has the advantage of greatly simplifying the theoretical analysis of the data. After an initial surge of measurements, the EC approach did not seem to be competitive. But very recently, there has been great progress on micro-calorimeters and the measurement of atomic mass differences. Meanwhile, the beta-decay neutrino-mass limits have improved by a factor of 15, and the difficulty of the experiments by the cube of that figure. Can the "calorimetric" EC theory cope with this increased challenge? I answer this question affirmatively. In so doing I briefly review the subject and extensively address some persistent misunderstandings of the underlying quantum physics.

  4. Reliability of ultrasonographic measurements in suspected patients of developmental dysplasia of the hip and correlation with the acetabular index

    Directory of Open Access Journals (Sweden)

    Cem Copuroglu

    2011-01-01

    Full Text Available Background: Ultrasonography is accepted as a useful imaging modality in the early detection of developmental dysplasia of the hip (DDH. Early detection and early treatment of DDH prevents hip dislocation and related physical, social, economic, and psychological problems. The purpose of this study was to evaluate the reliability of ultrasonographic and roentgenographic measurements measured by seven different observers. Materials and Methods: The alpha angles of 66 hips in 33 patients were measured using the Graf method by seven different observers. Acetabular index degrees on plane roentgenograms were measured in order to assess the correlation between the ultrasonographic alpha angle and the radiographic acetabular index, which both show the bony acetabular depth, retrospectively. Results: The interclass correlation coefficient, measuring the interobserver reliability, was high and statistically significant for the ultrasonographic measurements. There was a negative correlation between the alpha angle and the acetabular index. Conclusions: Ultrasonography, when applied properly, is a reliable technique between different observers, in the diagnosis and follow up of DDH. When assessed concomitantly with the roentgenographic measurements, the results are reliable and statistically meaningful.

  5. Measuring Student Self-Perceptions of Writing Skills in Programs of Journalism and Mass Communication

    Science.gov (United States)

    Lingwall, Andrew; Kuehn, Scott

    2013-01-01

    This study explored student self-perceptions of writing skills in journalism and mass communication programs at thirteen public state universities in the mid-Atlantic region. Factor analysis revealed seven sets of perceptions among 860 students. A Media Writing Self-Perception Scale was constructed and found to be reliable. The authors propose…

  6. Body mass index and blood pressure measurement during pregnancy.

    LENUS (Irish Health Repository)

    Hogan, Jennifer L

    2012-02-01

    OBJECTIVE: The accurate measurement of blood pressure requires the use of a large cuff in subjects with a high mid-arm circumference (MAC). This prospective study examined the need for a large cuff during pregnancy and its correlation with maternal obesity. METHODS: Maternal body mass index (BMI), fat mass, and MAC were measured. RESULTS: Of 179 women studied, 15.6% were obese. With a BMI of level 1 obesity, 44% needed a large cuff and with a BMI of level 2 obesity 100% needed a large cuff. CONCLUSION: All women booking for antenatal care should have their MAC measured to avoid the overdiagnosis of pregnancy hypertension.

  7. Combined Measurements of the Higgs Boson Mass and Couplings

    CERN Document Server

    Zhang, Yu; The ATLAS collaboration

    2017-01-01

    Combined measurements of the Higgs boson mass, as well its production cross sections and branching fractions, are performed using the H->yy and H->ZZ->4l decay channels. The measurements are based on 36.1 fb−1 of proton-proton collision data recorded by the ATLAS experiment at the LHC at sqrt(s)= 13 TeV. The Higgs boson mass is measured to be 124.98 +/- 0.19 (stat) +/- 0.21 (syst) GeV. The rates for gluon fusion, vector-boson fusion, VH, and ttH production, as well as kinematic subdivisions of these processes, are found to be compatible with the Standard Model. The measured ratios of the Higgs boson couplings to their SM predictions are also consistent with the predictions.

  8. Intracellular Water Exchange for Measuring the Dry Mass, Water Mass and Changes in Chemical Composition of Living Cells

    Science.gov (United States)

    Hecht, Vivian C.; Son, Sungmin; Li, Yingzhong; Knudsen, Scott M.; Olcum, Selim; Higgins, John M.; Chen, Jianzhu; Grover, William H.; Manalis, Scott R.

    2013-01-01

    We present a method for direct non-optical quantification of dry mass, dry density and water mass of single living cells in suspension. Dry mass and dry density are obtained simultaneously by measuring a cell’s buoyant mass sequentially in an H2O-based fluid and a D2O-based fluid. Rapid exchange of intracellular H2O for D2O renders the cell’s water content neutrally buoyant in both measurements, and thus the paired measurements yield the mass and density of the cell’s dry material alone. Utilizing this same property of rapid water exchange, we also demonstrate the quantification of intracellular water mass. In a population of E. coli, we paired these measurements to estimate the percent dry weight by mass and volume. We then focused on cellular dry density – the average density of all cellular biomolecules, weighted by their relative abundances. Given that densities vary across biomolecule types (RNA, DNA, protein), we investigated whether we could detect changes in biomolecular composition in bacteria, fungi, and mammalian cells. In E. coli, and S. cerevisiae, dry density increases from stationary to exponential phase, consistent with previously known increases in the RNA/protein ratio from up-regulated ribosome production. For mammalian cells, changes in growth conditions cause substantial shifts in dry density, suggesting concurrent changes in the protein, nucleic acid and lipid content of the cell. PMID:23844039

  9. THE CONCEPTUALISATION AND OPERATIONAL MEASUREMENT OF PRICE FAIRNESS PERCEPTION IN MASS SERVICE CONTEXT

    Directory of Open Access Journals (Sweden)

    Saowanee Srikanjanarak

    2009-01-01

    Full Text Available This paper aims to develop a measure of price fairness perception by extending price fairness conceptualisation to a multi-scale measure, thereby capturing its complexity in a mass service context. The service context is becoming increasingly competitive, particularly in the telecommunication industry, where a variety of service options is offered (e.g., mobile phone services. A review of price fairness perception literature usually focuses on the equity and social exchange theory and upon findings from exploratory research of the current market situation. In this article, the measure is conceptualised to entail a more extensive set of dimensions. These dimensions include the following: flexible price, reasonable price, acceptable price and superior price. Previous researchers have used actual price to focus on the structure and price comparison of competitors within the service industry. In contrast, this research has focused on the price comparison in terms of relative price. Additionally, we use a survey to elicit responses from 998 individual users of prepaid mobile phone services in Thailand. The results indicate a valid and reliable measure of price fairness perception, permitting us to understand how customers perceive that a price offered by service providers is fair. This understanding will help managers (and their respective organisations to design an appropriate price strategy that fits what their customer's wants and needs while fostering a long-term relationship with them.

  10. Intrarater reliability of hand held dynamometry in measuring lower extremity isometric strength using a portable stabilization device.

    Science.gov (United States)

    Jackson, Steven M; Cheng, M Samuel; Smith, A Russell; Kolber, Morey J

    2017-02-01

    Hand held dynamometry (HHD) is a more objective way to quantify muscle force production (MP) compared to traditional manual muscle testing. HHD reliability can be negatively impacted by both the strength of the tester and the subject particularly in the lower extremities due to larger muscle groups. The primary aim of this investigation was to assess intrarater reliability of HHD with use of a portable stabilization device for lower extremity MP in an athletic population. Isometric lower extremity strength was measured for bilateral lower extremities including hip abductors, external rotators, adductors, knee extensors, and ankle plantar flexors was measured in a sample of healthy recreational runners (8 male, 7 females, = 30 limbs) training for a marathon. These measurements were assessed using an intrasession intrarater reliability design. Intraclass correlation coefficients (ICC) were calculated using 3,1 model based on the single rater design. The standard error of measurement (SEM) for each muscle group was also calculated. ICC were excellent ranging from ICC (3,1) = 0.93-0.98 with standard error of measurements ranging from 0.58 to 17.2 N. This study establishes the use of a HHD with a portable stabilization device as demonstrating good reliability within testers for measuring lower extremity muscle performance in an active healthy population. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. The reliability of the Extra Load Index as a measure of relative load carriage economy.

    Science.gov (United States)

    Hudson, Sean; Cooke, Carlton; Lloyd, Ray

    2017-09-01

    The aim of this study was to measure the reliability of the extra load index (ELI) as a method for assessing relative load carriage economy. Seventeen volunteers (12 males, 5 females) performed walking trials at 3 km·h -1 , 6 km·h -1 and a self-selected speed. Trial conditions were repeated 7 days later to assess test-retest reliability. Trials involved four 4-minute periods of walking, each separated by 5 min of rest. The initial stage was performed unloaded followed in a randomised order by a second unloaded period and walking with backpacks of 7 and 20 kg. Results show ELI values did not differ significantly between trials for any of the speeds (p = 0.46) with either of the additional loads (p = 0.297). The systematic bias, limits of agreement and coefficients of variation were small in all trial conditions. We conclude the ELI appears to be a reliable measure of relative load carriage economy. Practitioner Summary: This paper demonstrates that the ELI is a reliable measure of load carriage economy at a range of walking speeds with both a light and heavy load. The ELI, therefore, represents a useful tool for comparing the relative economy associated with different load carriage systems.

  12. Nerve ultrasound reliability of upper limbs: Effects of examiner training.

    Science.gov (United States)

    Garcia-Santibanez, Rocio; Dietz, Alexander R; Bucelli, Robert C; Zaidman, Craig M

    2018-02-01

    Duration of training to reliably measure nerve cross-sectional area with ultrasound is unknown. A retrospective review was performed of ultrasound data, acquired and recorded by 2 examiners-an expert and either a trainee with 2 months (novice) or a trainee with 12 months (experienced) of experience. Data on median, ulnar, and radial nerves were reviewed for 42 patients. Interrater reliability was good and varied most with nerve site but little with experience. Coefficient of variation (CoV) range was 9.33%-22.5%. Intraclass correlation coefficient (ICC) was good to excellent (0.65-95) except ulnar nerve-wrist/forearm and radial nerve-humerus (ICC = 0.39-0.59). Interrater differences did not vary with nerve size or body mass index. Expert-novice and expert-experienced interrater differences and CoV were similar. The ulnar nerve-wrist expert-novice interrater difference decreased with time (r s  = -0.68, P = 0.001). A trainee with at least 2 months of experience can reliably measure upper limb nerves. Reliability varies by nerve and location and slightly improves with time. Muscle Nerve 57: 189-192, 2018. © 2017 Wiley Periodicals, Inc.

  13. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD

    Directory of Open Access Journals (Sweden)

    Formiga MF

    2018-05-01

    Full Text Available Magno F Formiga,1,2 Kathryn E Roach,1 Isabel Vital,3 Gisel Urdaneta,3 Kira Balestrini,3 Rafael A Calderon-Candelario,3,4 Michael A Campos,3,4,* Lawrence P Cahalin1,* 1Department of Physical Therapy, University of Miami Miller School of Medicine, Coral Gables, FL, USA; 2CAPES Foundation, Ministry of Education of Brazil, Brasilia, Brazil; 3Pulmonary Section, Miami Veterans Administration Medical Center, Miami, FL, USA; 4Division of Pulmonary, Allergy, Critical Care and Sleep Medicine, University of Miami Miller School of Medicine, Miami, FL, USA *These authors contributed equally to this work Purpose: The Test of Incremental Respiratory Endurance (TIRE provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP over time. The integration of MIP over inspiratory duration (ID provides the sustained maximal inspiratory pressure (SMIP. Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Patients and methods: Test–retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. Results: All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test–retest reliability with a nearly perfect intraclass correlation coefficient (ICC of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP

  14. Measurement of the Higgs boson mass with the ATLAS detector

    Directory of Open Access Journals (Sweden)

    Garay Walls F. M.

    2015-01-01

    Full Text Available A summary of the latest results on the combined measurement of the Higgs boson mass in the H → ZZ* → 4l and the H → γγ decay channels with the ATLAS detector is presented. The analysis uses 25 fb−1 of pp collision data recorded by the ATLAS detector at the CERN Large Hadron Collider at centre-of-mass energies of 7TeV and 8 TeV during 2011 and 2012. The combined measured value of the Higgs boson mass is mH = 125.36 ± 0.37 (stat ± 0.18 (syst GeV.

  15. Validity and intra-rater reliability of an android phone application to measure cervical range-of-motion.

    Science.gov (United States)

    Quek, June; Brauer, Sandra G; Treleaven, Julia; Pua, Yong-Hao; Mentiplay, Benjamin; Clark, Ross Allan

    2014-04-17

    Concurrent validity and intra-rater reliability using a customized Android phone application to measure cervical-spine range-of-motion (ROM) has not been previously validated against a gold-standard three-dimensional motion analysis (3DMA) system. Twenty-one healthy individuals (age:31 ± 9.1 years, male:11) participated, with 16 re-examined for intra-rater reliability 1-7 days later. An Android phone was fixed on a helmet, which was then securely fastened on the participant's head. Cervical-spine ROM in flexion, extension, lateral flexion and rotation were performed in sitting with concurrent measurements obtained from both a 3DMA system and the phone.The phone demonstrated moderate to excellent (ICC = 0.53-0.98, Spearman ρ = 0.52-0.98) concurrent validity for ROM measurements in cervical flexion, extension, lateral-flexion and rotation. However, cervical rotation demonstrated both proportional and fixed bias. Excellent intra-rater reliability was demonstrated for cervical flexion, extension and lateral flexion (ICC = 0.82-0.90), but poor for right- and left-rotation (ICC = 0.05-0.33) using the phone. Possible reasons for the outcome are that flexion, extension and lateral-flexion measurements are detected by gravity-dependent accelerometers while rotation measurements are detected by the magnetometer which can be adversely affected by surrounding magnetic fields. The results of this study demonstrate that the tested Android phone application is valid and reliable to measure ROM of the cervical-spine in flexion, extension and lateral-flexion but not in rotation likely due to magnetic interference. The clinical implication of this study is that therapists should be mindful of the plane of measurement when using the Android phone to measure ROM of the cervical-spine.

  16. On the Reliability of Implicit and Explicit Memory Measures.

    Science.gov (United States)

    Buchner, Axel; Wippich, Werner

    2000-01-01

    Studied the reliability of implicit and explicit memory tests in experiments involving these tests. Results with 168, 84, 120, and 128 undergraduates show that methodological artifacts may cause implicit memory tests to have lower reliability than explicit memory tests, but that implicit tests need not necessarily be less reliable. (SLD)

  17. Reliability of the Danish version of the McGill ingestive skills assessment for observation-based measures during meals

    DEFF Research Database (Denmark)

    Hansen, Tina; Lambert, Heather C; Faber, Jens

    2012-01-01

    To establish measurement equivalence in terms of reliability of the Danish version of the Canadian McGill ingestive skills assessment (MISA) for use by occupational therapists.......To establish measurement equivalence in terms of reliability of the Danish version of the Canadian McGill ingestive skills assessment (MISA) for use by occupational therapists....

  18. Soft drop jet mass measurement

    CERN Document Server

    Roloff, Jennifer Kathryn; The ATLAS collaboration

    2018-01-01

    Calculations of jet substructure observables that are accurate beyond leading-logarithm accuracy have recently become available. Such observables are significant not only for probing the collinear regime of QCD that is largely unexplored at a hadron collider, but also for improving the understanding of jet substructure properties that are used in many studies at the Large Hadron Collider. This poster documents a measurement of the first jet substructure quantity at a hadron collider to be calculated at next-to-next-to-leading-logarithm accuracy. The normalized, differential cross-section is measured as a function of log( ρ^2), where ρ is the ratio of the soft-drop mass to the ungroomed jet transverse momentum. This quantity is measured in dijet events from 32.9 ifb of sqrt(s) = 13 TeV proton-proton collisions recorded by the ATLAS detector. The data are unfolded to correct for detector effects and compared to precise QCD calculations and leading-logarithm particle-level Monte Carlo simulations.

  19. MEASURING THE MASS OF SOLAR SYSTEM PLANETS USING PULSAR TIMING

    International Nuclear Information System (INIS)

    Champion, D. J.; Hobbs, G. B.; Manchester, R. N.; Edwards, R. T.; Burke-Spolaor, S.; Sarkissian, J. M.; Backer, D. C.; Bailes, M.; Bhat, N. D. R.; Van Straten, W.; Coles, W.; Demorest, P. B.; Ferdman, R. D.; Purver, M. B.; Folkner, W. M.; Hotan, A. W.; Kramer, M.; Lommen, A. N.; Nice, D. J.; Stairs, I. H.

    2010-01-01

    High-precision pulsar timing relies on a solar system ephemeris in order to convert times of arrival (TOAs) of pulses measured at an observatory to the solar system barycenter. Any error in the conversion to the barycentric TOAs leads to a systematic variation in the observed timing residuals; specifically, an incorrect planetary mass leads to a predominantly sinusoidal variation having a period and phase associated with the planet's orbital motion about the Sun. By using an array of pulsars (PSRs J0437-4715, J1744-1134, J1857+0943, J1909-3744), the masses of the planetary systems from Mercury to Saturn have been determined. These masses are consistent with the best-known masses determined by spacecraft observations, with the mass of the Jovian system, 9.547921(2) x10 -4 M sun , being significantly more accurate than the mass determined from the Pioneer and Voyager spacecraft, and consistent with but less accurate than the value from the Galileo spacecraft. While spacecraft are likely to produce the most accurate measurements for individual solar system bodies, the pulsar technique is sensitive to planetary system masses and has the potential to provide the most accurate values of these masses for some planets.

  20. First Mass Measurement of a 'Domestic' Microlens

    Science.gov (United States)

    Dong, Subo; Carey, Sean; Gould, Andrew; Zhu, Wei

    2017-11-01

    We propose to combine Spitzer, Gaia, and ground-based measurements to determine the mass, distance, and transverse velocity of the 'domestic' microlensing event J0507+2447. This is only the second 'domestic' event (microlensed source distance less than about 1 kpc) ever discovered, but this number is already 10 times higher than the number that are expected. Hence, determining the nature of these lenses would resolve a major puzzle. The low expected rate is what caused Einstein to delay publication of his microlensing idea by 24 years. By very good fortune, Spitzer's narrow 38 day window of observations overlaps magnified portions of the event. To determine the mass requires to measure both the 'microlens parallax' (courtesy of Spitzer) and the 'angular Einstein radius' (which can be derived from Gaia astrometry). Thus, this is a truly rare opportunity to probe the nature of 'domestic' microlenses.

  1. Test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy.

    Science.gov (United States)

    Savva, Christos; Giakas, Giannis; Efstathiou, Michalis; Karagiannis, Christos

    2014-01-01

    The purpose of this study was to evaluate the test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy (CR). A convenience sample of 19 participants (14 men and 5 women; mean ± SD age, 50.5 ± 12 years) with CR was measured using a Jamar hydraulic hand dynamometer by the same rater on 2 different testing sessions with an interval of 7 days between sessions. Data collection procedures followed standardized grip strength testing guidelines established by the American Society of Hand Therapists. During the repeated measures, patients were advised to rest their upper limb in the standardized arm position and encouraged to exert 3 maximum gripping efforts. The mean value of the 3 efforts (measured in kilogram force [Kgf]) was used for data analysis. The intraclass correlation coefficient, SEM, and the Bland-Altman plot were used to estimate test-retest reliability and measurement precision. Grip strength measurement in CR demonstrated an intraclass correlation coefficient of 0.976, suggesting excellent test-retest reliability. The small SEM in both testing sessions (SEM1, 2.41 Kgf; SEM2, 2.51 Kgf) as well as the narrow width of the 95% limits of agreements (95% limits of agreement, -4.9 to 4.4 Kgf) in the Bland-Altman plot reflected precise measurements of grip strength in both occasions. Excellent test-retest reliability for grip strength measurement was measured in patients with CR, demonstrating that a hydraulic hand dynamometer could be used as an outcome measure for these patients. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  2. Accuracy and reliability of facial soft tissue depth measurements using cone beam computer tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Gerrits, Pieter; Ren, Yijin

    2010-01-01

    It is important to have accurate and reliable measurements of soft tissue thickness for specific landmarks of the face and scalp when producing a facial reconstruction. In the past several methods have been created to measure facial soft tissue thickness (FSTT) in cadavers and in the living. The

  3. Reliability analysis of a phaser measurement unit using a generalized fuzzy lambda-tau(GFLT) technique.

    Science.gov (United States)

    Komal

    2018-05-01

    Nowadays power consumption is increasing day-by-day. To fulfill failure free power requirement, planning and implementation of an effective and reliable power management system is essential. Phasor measurement unit(PMU) is one of the key device in wide area measurement and control systems. The reliable performance of PMU assures failure free power supply for any power system. So, the purpose of the present study is to analyse the reliability of a PMU used for controllability and observability of power systems utilizing available uncertain data. In this paper, a generalized fuzzy lambda-tau (GFLT) technique has been proposed for this purpose. In GFLT, system components' uncertain failure and repair rates are fuzzified using fuzzy numbers having different shapes such as triangular, normal, cauchy, sharp gamma and trapezoidal. To select a suitable fuzzy number for quantifying data uncertainty, system experts' opinion have been considered. The GFLT technique applies fault tree, lambda-tau method, fuzzified data using different membership functions, alpha-cut based fuzzy arithmetic operations to compute some important reliability indices. Furthermore, in this study ranking of critical components of the system using RAM-Index and sensitivity analysis have also been performed. The developed technique may be helpful to improve system performance significantly and can be applied to analyse fuzzy reliability of other engineering systems. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  4. Experiment for a precision neutrino mass measurement

    International Nuclear Information System (INIS)

    Fackler, O.; Mugge, M.; Sticker, H.; Woerner, R.

    1984-04-01

    We describe an experiment which is designed to determine the electron neutrino mass to better than 2 eV. Key features of the experiment are a high activity frozen tritium source and a high resolution electrostatic spectrometer designed to make a careful measurement of the tritium beta decay end point spectrum. The goal is to determine the neutrino mass to better than 1 eV statistically in a four day run. A series of these runs will allow study of potential systematics. The construction phase is nearly complete and preliminary data will be taken in late spring

  5. Measurements of the $W$ Boson Mass with the D0 Detector

    Energy Technology Data Exchange (ETDEWEB)

    Lopes de Sa, Rafael [Stony Brook Univ., NY (United States)

    2013-01-01

    In the first part, we describe what is the W boson mass in the context of the Standard Model. We discuss the prominent role this physical observable plays in the determination of the internal self consistency of the Electroweak Sector. We review measurements and calculation of the W boson mass done in past and argue about the importance and feasibility of improving the experimental determination. We give a description of the Fermilab Tevatron Collider and the D0 detector, highlighting the relevant parts for the measurement described in this Dissertation. In the second part, we give a detailed description of a measurement of the W boson mass using the D0 Central Calorimeter. The measurement uses 1.68 x 106 candidates from W → en decays, corresponding to 4.3 fb-1 of integrated luminosity collected from 2006 to 2009. We measure the mass using the transverse mass, electron transverse momentum, and missing transverse energy distributions. The transverse mass and electron transverse momentum measurements are the most precise and are combined to give MW = 80.367 ± 0.013(stat) ± 0.023 (syst) GeV = 80.367 ± 0.026 GeV. This is combined with an earlier D0 result determined using an independent 1 fb-1 data sample, also with central electrons only, to give MW = 80.375± 0.023 GeV. The uncertainty in the measurement is dominated by the determination of the calorimeter electron energy scale, the W sample size, the knowledge of the parton distribution function. In the third part, we discuss methods of reducing the dominant uncertainties in the W boson mass measurements. We show that introducing electrons detected in the End Calorimeters greatly reduce the measurement systematic uncertainty, especially the on related to the parton distribution functions. We describe a precise calibration of the End Calorimeter using Z → ee events corresponding to 4.3 fb-1 of integrated luminosity. The calibration is an important

  6. Reliability and reproducibility of disc-foveal angle measurements by non-mydriatic fundus photography.

    Science.gov (United States)

    Le Jeune, Caroline; Chebli, Fayçal; Leon, Lorette; Anthoine, Emmanuelle; Weber, Michel; Péchereau, Alain; Lebranchu, Pierre

    2018-01-01

    Abnormal torsion could be associated with cyclovertical strabismus, but torsion measurements are not reliable in children. To assess an objective fundus torsion evaluation in a paediatric population, we used Non-Mydriatic Fundus photography (NMFP) in healthy and cyclovertical strabismus patients to evaluate the disc-foveal angle over time and observers. We used a retrospective set of NMFP including 24 A or V-pattern strabismus and 27 age-matched normal children (mean age 6.4 and 6.7 years respectively), taken during 2 distinct follow-up consultations (separated by 251 and 479 days respectively). Each disc-foveal angle measurement (from which the ocular torsion can be assessed) was performed by 5 different observers, using graphical software and based on reproducible fundus anatomical marks. Statistical analysis was performed with a multivariate ANOVA using group, time and observers as factors, in addition to intraclass coefficient correlation (ICC) to assess measurement reproducibility. A significant difference of disc-foveal angle measures was observed between groups (p0,97). Abnormal amount of objective torsion could be associated with alphabet-pattern strabismus. Disc-foveal angle evaluation by NMFP in a children population appears as a non-invasive, reliable and reproducible method.

  7. Inter-rater reliability of measures to characterize the tobacco retail environment in Mexico

    Directory of Open Access Journals (Sweden)

    Marissa G Hall

    2015-11-01

    Full Text Available Objective. To evaluate the inter-rater reliability of a data collection instrument to assess the tobacco retail environ- ment in Mexico, after major marketing regulations were implemented. Materials and methods. In 2013, two data collectors independently evaluated 21 stores in two census tracts, through a data collection instrument that assessed the presence of price promotions, whether single cigarettes were sold, the number of visible advertisements, the pre- sence of signage prohibiting the sale of cigarettes to minors, and characteristics of cigarette pack displays. We evaluated the inter-rater reliability of the collected data, through the calculation of metrics such as intraclass correlation coefficient, percent agreement, Cohen’s kappa and Krippendorff’s alpha. Results. Most measures demonstrated substantial or perfect inter-rater reliability. Conclusions. Our results indicate the potential utility of the data collection instrument for future point-of-sale research.

  8. Jet energy measurements at ILC. Calorimeter DAQ requirements and application in Higgs boson mass measurements

    International Nuclear Information System (INIS)

    Ebrahimi, Aliakbar

    2017-11-01

    The idea of spontaneous symmetry breaking as the mechanism through which elementary particles gain mass has been confirmed by the discovery of the Higgs boson at the CERN Large Hadron Collider. Studying the Higgs boson properties are of great importance to verify the Standard Model predictions. Any deviation from these predictions could uncover physics beyond the Standard Model. The mass of the Higgs boson is one of the important parameters of the Standard Model. The precise determination of the Higgs boson mass is of interest in its own right and also for other Higgs physics studies since it enters as parametric uncertainty into the extraction of the partial width from branching ratio measurements. The International Linear Collider (ILC) is a future polarised e + e - collider designed for precision physics studies. The Higgs boson decay to a pair of bottom quarks H→b anti b has the largest branching ratio of all Higgs decays, providing a large dataset for physics analyses. The possibility of measuring the Higgs boson mass in the e + e - →ZH→q anti qb anti b channel is investigated in this thesis for centre-of-mass energies of 350 GeV and 500 GeV. Since the Higgs boson mass is reconstructed from two b jets, the jet energy resolution hasa high impact on the measurement. A new method to estimate the jet energy resolution for each jet individually is developed in this thesis. The jet-specific energy resolution is then used in the analysis for the Higgs boson mass measurements. Various strategies for the Higgs boson mass measurement are investigated. For an integrated luminosity of 1000 fb -1 and a beam polarisation of (-0.8,+0.3), statistical uncertainties of 42 MeV and 89 MeV are achieved for the centre-of-mass energies of 350 GeV and 500 GeV, respectively. Various sources of systematic uncertainties are also discussed. These results are obtained using a full GEANT4-based simulation of the International Large Detector (ILD) concept. The jet energy resolution

  9. Jet energy measurements at ILC. Calorimeter DAQ requirements and application in Higgs boson mass measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ebrahimi, Aliakbar

    2017-11-15

    The idea of spontaneous symmetry breaking as the mechanism through which elementary particles gain mass has been confirmed by the discovery of the Higgs boson at the CERN Large Hadron Collider. Studying the Higgs boson properties are of great importance to verify the Standard Model predictions. Any deviation from these predictions could uncover physics beyond the Standard Model. The mass of the Higgs boson is one of the important parameters of the Standard Model. The precise determination of the Higgs boson mass is of interest in its own right and also for other Higgs physics studies since it enters as parametric uncertainty into the extraction of the partial width from branching ratio measurements. The International Linear Collider (ILC) is a future polarised e{sup +}e{sup -} collider designed for precision physics studies. The Higgs boson decay to a pair of bottom quarks H→b anti b has the largest branching ratio of all Higgs decays, providing a large dataset for physics analyses. The possibility of measuring the Higgs boson mass in the e{sup +}e{sup -}→ZH→q anti qb anti b channel is investigated in this thesis for centre-of-mass energies of 350 GeV and 500 GeV. Since the Higgs boson mass is reconstructed from two b jets, the jet energy resolution hasa high impact on the measurement. A new method to estimate the jet energy resolution for each jet individually is developed in this thesis. The jet-specific energy resolution is then used in the analysis for the Higgs boson mass measurements. Various strategies for the Higgs boson mass measurement are investigated. For an integrated luminosity of 1000 fb{sup -1} and a beam polarisation of (-0.8,+0.3), statistical uncertainties of 42 MeV and 89 MeV are achieved for the centre-of-mass energies of 350 GeV and 500 GeV, respectively. Various sources of systematic uncertainties are also discussed. These results are obtained using a full GEANT4-based simulation of the International Large Detector (ILD) concept. The

  10. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    .08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability...

  11. Recent improvements of ISOLTRAP Absolute mass measurements of exotic nuclides at $10^{-8}$ precision

    CERN Document Server

    Kellerbauer, A G

    2003-01-01

    In the past three years, the sensitivity and the performance of the Penning trap mass spectrometer ISOLTRAP have been enhanced significantly. These improvements, which range from technical developments to systematic studies of the various factors contributing to the uncertainty of the final mass result, now allow mass measurements of short-lived radionuclides with half-lives of less than 100 ms and with a precision of better than 10$^{-8}$. Using a newly developed carbon cluster ion source, ISOLTRAP can perform absolute mass measurements relative to the microscopic mass standard $^{12}$C. These developments are reviewed as pertaining to the extension of ISOLTRAP mass measurements to higher precision and shorter half-lives and to molecular mass measurements.

  12. Test-retest reliability of sensor-based sit-to-stand measures in young and older adults.

    Science.gov (United States)

    Regterschot, G Ruben H; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and Five-Times-Sit-to-Stand Test (FTSST) in older adults. Ten healthy young female adults (20-23 years) and 31 older adults (21 females; 73-94 years) participated in two assessment sessions separated by 3-8 days. Vertical peak power was assessed during three (young adults) and five (older adults) normal and fast STS trials with a hybrid motion sensor worn on the hip. Older adults also performed the FTSST and TUGT. The average sensor-based STS peak power of the normal STS trials and the average sensor-based STS peak power of the fast STS trials showed excellent test-retest reliability in young adults (intra-class correlation (ICC)≥0.90; zero in 95% confidence interval of mean difference between test and retest (95%CI of D); standard error of measurement (SEM)≤6.7% of mean peak power) and older adults (ICC≥0.91; zero in 95%CI of D; SEM≤9.9%). Test-retest reliability of sensor-based STS peak power and TUGT (ICC=0.98; zero in 95%CI of D; SEM=8.5%) was comparable in older adults, test-retest reliability of the FTSST was lower (ICC=0.73; zero outside 95%CI of D; SEM=14.4%). Sensor-based STS peak power demonstrated excellent test-retest reliability and may therefore be useful for clinical assessment of functional status and fall risk. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Reliability of Ultrasonographic Measurement of Cervical Multifidus Muscle Dimensions during Isometric Contraction of Neck Muscles

    Directory of Open Access Journals (Sweden)

    Somayeh Amiri Arimi

    2012-07-01

    Full Text Available Background and Aim: Cervical multifidus is considered as one of the most important neck stabilizers. Weakness and muscular atrophy of this muscle were seen in patients with chronic neck pain. Ultrasonographic imaging is a non-invasive and feasible technique that commonly used to record such changes and measure muscle dimensions. Therefore, the aim of this study was to evaluate the reliability of ultrasonographic measurement of cervical multifidus muscle’s dimensions during isometric contraction of neck muscles. Materials and Method: Ten subjects (5 patients with chronic neck pain and 5 healthy subjects were recruited in this study. Cervical multifidus muscle’s dimensions were measured at the level of forth cervical vertebrae. Ultrasonographic measurement of cervical multifidus muscle at rest, 50% and 100% of maximal voluntary contraction (MVC were performed by one examiner within 1 week interval. The dimensions of cervical multifidus muscle including cross-sectional area (CSA, anterior posterior dimension (APD, and lateral dimension (LD were measured. Intraclass correlation coefficients (ICC, standard error of measurement (SEM and minimal detectable change (MDC were computed for data analysis.Results: The between days reliability of maximum strength of neck muscles and multifidus muscle dimensions at rest, 50% and 100% of MVC of neck muscles were good to excellent (ICC=0.75-0.99.Conclusion: The results of this study showed that ultrasonographic measuring of cervical multifidus muscle’s dimensions during isometric contraction of neck muscles at the level of C4 in females with chronic neck pain and healthy subjects is a reliable and repeatable method.

  14. Investigation of the proton-neutron interaction by high-precision nuclear mass measurements

    CERN Multimedia

    Savreux, R P; Akkus, B

    2007-01-01

    We propose to measure the atomic masses of a series of short-lived nuclides, including $^{70}$Ni, $^{122-130}$Cd, $^{134}$Sn, $^{138,140}$Xe, $^{207-210}$Hg, and $^{223-225}$Rn, that contribute to the investigation of the proton-neutron interaction and its role in nuclear structure. The high-precision mass measurements are planned for the Penning trap mass spectrometer ISOLTRAP that reaches the required precision of 10 keV in the nuclear mass determination.

  15. Generalizability Theory Reliability of Written Expression Curriculum-Based Measurement in Universal Screening

    Science.gov (United States)

    Keller-Margulis, Milena A.; Mercer, Sterett H.; Thomas, Erin L.

    2016-01-01

    The purpose of this study was to examine the reliability of written expression curriculum-based measurement (WE-CBM) in the context of universal screening from a generalizability theory framework. Students in second through fifth grade (n = 145) participated in the study. The sample included 54% female students, 49% White students, 23% African…

  16. Establishing Reliability and Construct Validity for an Instrument to Measure Environmental Connectedness

    Science.gov (United States)

    Beery, Thomas H.

    2013-01-01

    The purpose of this preliminary study is to establish a reliable and valid measure of environmental connectedness (EC) to allow for further exploration of the Swedish Outdoor Recreation in Change national survey data. The Nordic concept of friluftsliv (nature-based outdoor recreation) and the environmental psychology concept of EC are explored to…

  17. The Nutrition Literacy Assessment Instrument is a Valid and Reliable Measure of Nutrition Literacy in Adults with Chronic Disease.

    Science.gov (United States)

    Gibbs, Heather D; Ellerbeck, Edward F; Gajewski, Byron; Zhang, Chuanwu; Sullivan, Debra K

    2018-03-01

    To test the reliability and validity of the Nutrition Literacy Assessment Instrument (NLit) in adult primary care and identify the relationship between nutrition literacy and diet quality. This instrument validation study included a cross-sectional sample participating in up to 2 visits 1 month apart. A total of 429 adults with nutrition-related chronic disease were recruited from clinics and a patient registry affiliated with a Midwestern university medical center. Nutrition literacy was measured by the NLit, which was composed of 6 subscales: nutrition and health, energy sources in food, food label and numeracy, household food measurement, food groups, and consumer skills. Diet quality was measured by Healthy Eating Index-2010 with nutrient data from Diet History Questionnaire II surveys. The researchers measured factor validity and reliability by using binary confirmatory factor analysis; test-retest reliability was measured by Pearson r and the intraclass correlation coefficient, and relationships between nutrition literacy and diet quality were analyzed by linear regression. The NLit demonstrated substantial factor validity and reliability (0.97; confidence interval, 0.96-0.98) and test-retest reliability (0.88; confidence interval, 0.85-0.90). Nutrition literacy was the most significant predictor of diet quality (β = .17; multivariate coefficient = 0.10; P measuring nutrition literacy in adult primary care patients. Copyright © 2017 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  18. Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull.

    Science.gov (United States)

    Berco, Mauricio; Rigali, Paul H; Miner, R Matthew; DeLuca, Stephelynn; Anderson, Nina K; Will, Leslie A

    2009-07-01

    The purpose of this study was to determine the accuracy and reliability of 3-dimensional craniofacial measurements obtained from cone-beam computed tomography (CBCT) scans of a dry human skull. Seventeen landmarks were identified on the skull. CBCT scans were then obtained, with 2 skull orientations during scanning. Twenty-nine interlandmark linear measurements were made directly on the skull and compared with the same measurements made on the CBCT scans. All measurements were made by 2 operators on 4 separate occasions. The method errors were 0.19, 0.21, and 0.19 mm in the x-, y- and z-axes, respectively. Repeated measures analysis of variance (ANOVA) showed no significant intraoperator or interoperator differences. The mean measurement error was -0.01 mm (SD, 0.129 mm). Five measurement errors were found to be statistically significantly different; however, all measurement errors were below the known voxel size and clinically insignificant. No differences were found in the measurements from the 2 CBCT scan orientations of the skull. CBCT allows for clinically accurate and reliable 3-dimensional linear measurements of the craniofacial complex. Moreover, skull orientation during CBCT scanning does not affect the accuracy or the reliability of these measurements.

  19. Intra-observer and interobserver reliability ofOne Leg Stand Test as a measure of posturalbalance in low back pain patients

    DEFF Research Database (Denmark)

    Maribo, Thomas; Iversen, Elena; Andersen, Niels Trolle

    2009-01-01

    Objective: To determine the absolute and relative reliability of intra-observer and interobserver To determine the absolute and relative reliability of intra-observer and interobserver measurements of postural balance using the One Leg Stand Test in patients with low back pain. Patients and methods...... to stand for the maximum time, and no further analysis was done. Eyes closed: intra-observer reliability was tested in 21 patients; absolute reliability showed a standard error of the measurement (SEM) of 2.48 s and a minimal detectable change (MDC) of 6.88. The relative reliability was acceptable...... with an intra class correlation coefficient (ICC) of 0.86. Interobserver reliability was tested in 27 patients; absolute reliability showed a SEM of 1.42 s and a MDC of 3.95. The relative reliability was acceptable with an ICC of 0.91. Conclusions: The One Leg Stand Test can be used to test postural balance...

  20. Measuring Method for Fuzz Mass of Carbon Fiber Tow

    Directory of Open Access Journals (Sweden)

    LI Tan

    2017-07-01

    Full Text Available In order to quantitatively test fuzz degree of carbon fiber (CF tow, a measuring method for fuzz mass of CF tow was developed, and the testing device was built. Fuzz mass of two kinds of domestic T800-grade CF were tested using the established method. The effects of spreading width of CF tow, tension and fuzz-adsorption material on the fuzz mass of the two fibers were investigated. Several kinds of imported, domestic T700-grade CF and T800-grade CF were tested using optimized testing conditions. The experimental results show that the testing method is easy to operate and has wide applicability. Under 1-2N tension, 0.1-0.6mm pore size of sponge and 1-4N load applied on sponge, the measured values of T800-grade CF with 12K yield are reasonable. For CF tow with high fuzz mass, certain spreading width makes fuzz inside fiber bundle expose, which is needed to ensure the accuracy of testing result.

  1. Pattern of alveolar bone loss and reliability of measurements with the radiographic technique

    International Nuclear Information System (INIS)

    Rise, J.; Albandar, J.M.

    1988-01-01

    The purposes of this paper were to study the pattern of bone loss among different teeth at the individual level and to study the effect of using different aggregated units of analysis on measurement error. Bone loss was assessed in standardized periapical radiographs from 293 subjects (18-68 years), and the mean bone loss score for each tooth type was calculated. These were then correlated by means of factor analysis to study the bone loss pattern. Reliability (measurement error) was studied by the internal consistency and the test-retest methods. The pattern of bone loss showed a unidimensional pattern, indicating that any tooth will work equally well as a dependent variable for epidemiologic descriptive purposes. However, a more thorough analysis also showed a multidimensional pattern in terms of four dimensions, which correspond to four tooth groups: incisors, upper premolars, lower premolars and molars. The four dimensions accounted for 80% of the toal variance. The multidimensional pattern may be important for the modeling of bone loss; thus different models may explain the four dimension (indices) used as dependent variables. The reliability (internal consistency) of the four indices was satisfactory. By the test-retest method, reliability was higher when the more aggregated unit (the individual) was used

  2. Geoelectrical Measurement of Multi-Scale Mass Transfer Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Day-Lewis, Frederick David [US Geological Survey, Storrs, CT (United States); Singha, Kamini [Colorado School of Mines, Golden, CO (United States); Johnson, Timothy C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Haggerty, Roy [Oregon State Univ., Corvallis, OR (United States); Binley, Andrew [Lancaster Univ. (United Kingdom); Lane, John W. [US Geological Survey, Storrs, CT (United States)

    2014-11-25

    Mass transfer affects contaminant transport and is thought to control the efficiency of aquifer remediation at a number of sites within the Department of Energy (DOE) complex. An improved understanding of mass transfer is critical to meeting the enormous scientific and engineering challenges currently facing DOE. Informed design of site remedies and long-term stewardship of radionuclide-contaminated sites will require new cost-effective laboratory and field techniques to measure the parameters controlling mass transfer spatially and across a range of scales. In this project, we sought to capitalize on the geophysical signatures of mass transfer. Previous numerical modeling and pilot-scale field experiments suggested that mass transfer produces a geoelectrical signature—a hysteretic relation between sampled (mobile-domain) fluid conductivity and bulk (mobile + immobile) conductivity—over a range of scales relevant to aquifer remediation. In this work, we investigated the geoelectrical signature of mass transfer during tracer transport in a series of controlled experiments to determine the operation of controlling parameters, and also investigated the use of complex-resistivity (CR) as a means of quantifying mass transfer parameters in situ without tracer experiments. In an add-on component to our grant, we additionally considered nuclear magnetic resonance (NMR) to help parse mobile from immobile porosities. Including the NMR component, our revised study objectives were to: 1. Develop and demonstrate geophysical approaches to measure mass-transfer parameters spatially and over a range of scales, including the combination of electrical resistivity monitoring, tracer tests, complex resistivity, nuclear magnetic resonance, and materials characterization; and 2. Provide mass-transfer estimates for improved understanding of contaminant fate and transport at DOE sites, such as uranium transport at the Hanford 300 Area. To achieve our objectives, we implemented a 3

  3. Independent component analysis for the extraction of reliable protein signal profiles from MALDI-TOF mass spectra.

    Science.gov (United States)

    Mantini, Dante; Petrucci, Francesca; Del Boccio, Piero; Pieragostino, Damiana; Di Nicola, Marta; Lugaresi, Alessandra; Federici, Giorgio; Sacchetta, Paolo; Di Ilio, Carmine; Urbani, Andrea

    2008-01-01

    Independent component analysis (ICA) is a signal processing technique that can be utilized to recover independent signals from a set of their linear mixtures. We propose ICA for the analysis of signals obtained from large proteomics investigations such as clinical multi-subject studies based on MALDI-TOF MS profiling. The method is validated on simulated and experimental data for demonstrating its capability of correctly extracting protein profiles from MALDI-TOF mass spectra. The comparison on peak detection with an open-source and two commercial methods shows its superior reliability in reducing the false discovery rate of protein peak masses. Moreover, the integration of ICA and statistical tests for detecting the differences in peak intensities between experimental groups allows to identify protein peaks that could be indicators of a diseased state. This data-driven approach demonstrates to be a promising tool for biomarker-discovery studies based on MALDI-TOF MS technology. The MATLAB implementation of the method described in the article and both simulated and experimental data are freely available at http://www.unich.it/proteomica/bioinf/.

  4. Measurement of W± boson mass at LEP by means of DELPHI detector

    International Nuclear Information System (INIS)

    Todorova-Nova, Sarka

    1998-01-01

    The thesis deals with measurement of the mass of the W boson at LEP2, based on the direct reconstruction of its decay products in the hadronic channel. A set of procedures necessary for the extraction of the W mass from the experimental data collected with the DELPHI detector in 1997 was developed (search of optimal variables for the event selection, development of a special method of kinematical reconstruction). The measured value of the mass was interpreted in the framework of the Standard Model, allowing to constrain the mass of the Higgs boson. A substantial part of the work is devoted to systematic effects due to the interactions between the hadronic decay products of the W bosons (colour reconnection and Bose-Einstein correlations), which may significantly influence the measurement of their mass. (author)

  5. Reliability and criterion validity of measurements using a smart phone-based measurement tool for the transverse rotation angle of the pelvis during single-leg lifting.

    Science.gov (United States)

    Jung, Sung-Hoon; Kwon, Oh-Yun; Jeon, In-Cheol; Hwang, Ui-Jae; Weon, Jong-Hyuck

    2018-01-01

    The purposes of this study were to determine the intra-rater test-retest reliability of a smart phone-based measurement tool (SBMT) and a three-dimensional (3D) motion analysis system for measuring the transverse rotation angle of the pelvis during single-leg lifting (SLL) and the criterion validity of the transverse rotation angle of the pelvis measurement using SBMT compared with a 3D motion analysis system (3DMAS). Seventeen healthy volunteers performed SLL with their dominant leg without bending the knee until they reached a target placed 20 cm above the table. This study used a 3DMAS, considered the gold standard, to measure the transverse rotation angle of the pelvis to assess the criterion validity of the SBMT measurement. Intra-rater test-retest reliability was determined using the SBMT and 3DMAS using intra-class correlation coefficient (ICC) [3,1] values. The criterion validity of the SBMT was assessed with ICC [3,1] values. Both the 3DMAS (ICC = 0.77) and SBMT (ICC = 0.83) showed excellent intra-rater test-retest reliability in the measurement of the transverse rotation angle of the pelvis during SLL in a supine position. Moreover, the SBMT showed an excellent correlation with the 3DMAS (ICC = 0.99). Measurement of the transverse rotation angle of the pelvis using the SBMT showed excellent reliability and criterion validity compared with the 3DMAS.

  6. Stress Rupture Life Reliability Measures for Composite Overwrapped Pressure Vessels

    Science.gov (United States)

    Murthy, Pappu L. N.; Thesken, John C.; Phoenix, S. Leigh; Grimes-Ledesma, Lorie

    2007-01-01

    Composite Overwrapped Pressure Vessels (COPVs) are often used for storing pressurant gases onboard spacecraft. Kevlar (DuPont), glass, carbon and other more recent fibers have all been used as overwraps. Due to the fact that overwraps are subjected to sustained loads for an extended period during a mission, stress rupture failure is a major concern. It is therefore important to ascertain the reliability of these vessels by analysis, since the testing of each flight design cannot be completed on a practical time scale. The present paper examines specifically a Weibull statistics based stress rupture model and considers the various uncertainties associated with the model parameters. The paper also examines several reliability estimate measures that would be of use for the purpose of recertification and for qualifying flight worthiness of these vessels. Specifically, deterministic values for a point estimate, mean estimate and 90/95 percent confidence estimates of the reliability are all examined for a typical flight quality vessel under constant stress. The mean and the 90/95 percent confidence estimates are computed using Monte-Carlo simulation techniques by assuming distribution statistics of model parameters based also on simulation and on the available data, especially the sample sizes represented in the data. The data for the stress rupture model are obtained from the Lawrence Livermore National Laboratories (LLNL) stress rupture testing program, carried out for the past 35 years. Deterministic as well as probabilistic sensitivities are examined.

  7. Improved mass-measurement accuracy using a PNB Load Cell Scale

    International Nuclear Information System (INIS)

    Suda, S.; Pontius, P.; Schoonover, R.

    1981-08-01

    The PNB Load Cell Scale is a Preloaded, Narrow-Band calibration mass comparator. It consists of (1) a frame and servo-mechanism that maintains a preload tension on the load cell until the load, an unknown mass, is sensed, and (2) a null-balance digital instrument that suppresses the cell response associated with the preload, thereby improving the precision and accuracy of the measurements. Ideally, the objects used to set the preload should be replica mass standards that closely approximate the density and mass of the unknowns. The advantages of the PNB scale are an expanded output signal over the range of interest which increases both the sensitivity and resolution, and minimizes the transient effects associated with loading of load cells. An area of immediate and practical application of this technique to nuclear material safeguards is the weighing of UF 6 cyliners where in-house mass standards are currently available and where the mass values are typically assigned on the basis of comparison weighings. Several prototypical versions of the PNB scale have been assembled at the US National Bureau of Standards. A description of the instrumentation, principles of measurements, and applications are presented in this paper

  8. Reliability and validity of the Performance Recorder 1 for measuring isometric knee flexor and extensor strength.

    Science.gov (United States)

    Neil, Sarah E; Myring, Alec; Peeters, Mon Jef; Pirie, Ian; Jacobs, Rachel; Hunt, Michael A; Garland, S Jayne; Campbell, Kristin L

    2013-11-01

    Muscular strength is a key parameter of rehabilitation programs and a strong predictor of functional capacity. Traditional methods to measure strength, such as manual muscle testing (MMT) and hand-held dynamometry (HHD), are limited by the strength and experience of the tester. The Performance Recorder 1 (PR1) is a strength assessment tool attached to resistance training equipment and may be a time- and cost-effective tool to measure strength in clinical practice that overcomes some limitations of MMT and HHD. However, reliability and validity of the PR1 have not been reported. Test-retest and inter-rater reliability was assessed using the PR1 in healthy adults (n  =  15) during isometric knee flexion and extension. Criterion-related validity was assessed through comparison of values obtained from the PR1 and Biodex® isokinetic dynamometer. Test-retest reliability was excellent for peak knee flexion (intra-class correlation coefficient [ICC] of 0.96, 95% CI: 0.85, 0.99) and knee extension (ICC  =  0.96, 95% CI: 0.87, 0.99). Inter-rater reliability was also excellent for peak knee flexion (ICC  =  0.95, 95% CI: 0.85, 0.99) and peak knee extension (ICC  =  0.97, 95% CI: 0.91, 0.99). Validity was moderate for peak knee flexion (ICC  =  0.75, 95% CI: 0.38, 0.92) but poor for peak knee extension (ICC  =  0.37, 95% CI: 0, 0.73). The PR1 provides a reliable measure of isometric knee flexor and extensor strength in healthy adults that could be used in the clinical setting, but absolute values may not be comparable to strength assessment by gold-standard measures.

  9. Miniature Sensor for Aerosol Mass Measurements, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR project seeks to develop a miniature sensor for mass measurement of size-classified aerosols. A cascade impactor will be used to classify aerosol sample...

  10. Sensitivity, reliability and the effects of diurnal variation on a test battery of field usable upper limb fatigue measures.

    Science.gov (United States)

    Yung, Marcus; Wells, Richard P

    2017-07-01

    Fatigue has been linked to deficits in production quality and productivity and, if of long duration, work-related musculoskeletal disorders. It may thus be a useful risk indicator and design and evaluation tool. However, there is limited information on the test-retest reliability, the sensitivity and the effects of diurnal fluctuation on field usable fatigue measures. This study reports on an evaluation of 11 measurement tools and their 14 parameters. Eight measures were found to have test-retest ICC values greater than 0.8. Four measures were particularly responsive during an intermittent fatiguing condition. However, two responsive measures demonstrated rhythmic behaviour, with significant time effects from 08:00 to mid-afternoon and early evening. Action tremor, muscle mechanomyography and perceived fatigue were found to be most reliable and most responsive; but additional analytical considerations might be required when interpreting daylong responses of MMG and action tremor. Practitioner Summary: This paper presents findings from test-retest and daylong reliability and responsiveness evaluations of 11 fatigue measures. This paper suggests that action tremor, muscle mechanomyography and perceived fatigue were most reliable and most responsive. However, mechanomyography and action tremor may be susceptible to diurnal changes.

  11. A novel concept of measuring mass flow rates using flow induced ...

    Indian Academy of Sciences (India)

    Measurement of mass flow rate is important for automatic control of the mass flow rate in .... mass flow rate. The details are as follows. ... Assuming a symmetry plane passing through the thickness of the plate, at the symmetry plane δu∗n,B = 0.

  12. Reliability of cervical lordosis and global sagittal spinal balance measurements in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Vidal, Christophe; Ilharreborde, Brice; Azoulay, Robin; Sebag, Guy; Mazda, Keyvan

    2013-06-01

    Radiological reproducibility study. To assess intra and interobserver reliability of radiographic measurements for global sagittal balance parameters and sagittal spine curves, including cervical spine. Sagittal spine balance in adolescent idiopathic scoliosis (AIS) is a main issue and many studies have been reported, showing that coronal and sagittal deformities often involve sagittal cervical unbalance. Global sagittal balance aims to obtain a horizontal gaze and gravity line at top of hips when subject is in a static position, involving adjustment of each spine curvature in the sagittal plane. To our knowledge, no study did use a methodologically validated imaging analysis tool able to appreciate sagittal spine contours and distances in AIS and especially in the cervical region. Lateral full-spine low-dose EOS radiographs were performed in 75 patients divided in three groups (control subjects, AIS, operated AIS). Three observers digitally analyzed twice each radiograph and 11 sagittal measures were collected for each image. Reliability was assessed calculating intraobserver Pearson's r correlation coefficient, interobserver intra-class correlation coefficient (ICC) completed with a two-by-two Bland-Altman plot analysis. This measurement method has shown excellent intra and interobserver reliability in all parameters, sagittal curvatures, pelvic parameters and global sagittal balance. This study validated a simple and efficient tool in AIS sagittal contour analysis. It defined new relevant landmarks allowing to characterize cervical segmental curvatures and cervical involvement in global balance.

  13. High-precision mass measurements in the realm of the deformed shell closure N=152

    Energy Technology Data Exchange (ETDEWEB)

    Eibach, Martin Andreas

    2013-12-04

    The nuclear masses reflect the sum of all interactions inside a nucleus. Their precise knowledge can be used to benchmark nuclear mass models and to gain nuclear structure information. Penning-trap mass spectrometers have proven their potential to obtain lowest uncertainties. Uniquely located at a nuclear reactor, the double Penning-trap mass spectrometer TRIGA-TRAP is dedicated to measurements in the neutron-rich region. For a gain in sensitivity a non-destructive detection system for single ion mass measurements was adopted. This includes the implementation of a narrow band-pass filter tuned to the heavy ion cyclotron frequency as well as a cryogenic low-noise amplifier. For on-line mass measurements, the laser ablation ion source was equipped with a newly developed miniature radiofrequency quadrupole trap in order to improve the extraction efficiency. A more economic use of the radioactive material enabled mass measurements using only 10{sup 15} atoms of target material. New mass measurements were performed within this work in the realm of the deformed shell closure N=152. Their implementation into the atomic-mass evaluation improved the uncertainty of more than 80 nuclides in the heavy mass region and simultaneously shifted the absolute mass of two α decay chains.

  14. Device for measurement of gas mass flow. Einrichtung zur Gasmassenstrommessung

    Energy Technology Data Exchange (ETDEWEB)

    Sass, W

    1989-09-28

    The invention is concerned with a device for the measurement of gas mass flow, particularly measuring air mass flow for vehicles with internal combustion engines, with a measurement bridge, in one branch of which a gas flow resistance, particularly a hot film sensor, with gas flowing round it, is connected in series with a measurement resistance and in another branch of which a compensation resistance measuring the gas temperature is connected in series with a fixed resistor, where the bridge differential voltage is measured in the zero branch of the measuring bridge and a control parameter is produced from this, in order to control a transistor valve situated in the bridge supply path of a DC voltage source via its control electrode until the bridge is balanced, and where the voltage at the measurement resistance after the bridge is balanced is used as a measure of the gas mass flow. In order to obtain exact results of measurement in spite of relatively high interference noise from the cables, it is proposed that an increased supply DC voltage appreciably decreasing the occurring interference noise from the cables should be produced from a small DC voltage and that the output of the DC/DC voltage converter should be connected to the control electrode of the transistor valve, so that the control parameter for the control electrode is derived from the raised DC supply voltage through reducers depending on the gas flow.

  15. Resonance ionization mass spectrometry system for measurement of environmental samples

    International Nuclear Information System (INIS)

    Pibida, L.; McMahon, C.A.; Noertershaeuser, W.; Bushaw, B.A.

    2002-01-01

    A resonance ionization mass spectrometry (RIMS) system has been developed at the National Institute of Standards and Technology (NIST) for sensitive and selective determination of radio-cesium in the environment. The overall efficiency was determined to be 4x10-7 with a combined (laser and mass spectrometer) selectivity of 108 for both 135Cs and 137Cs with respect to 133Cs. RIMS isotopic ratio measurements of 135Cs/ 137Cs were performed on a nuclear fuel burn-up sample and compared to measurements on a similar system at Pacific Northwest National Laboratory (PNNL) and to conventional thermal ionization mass spectrometry (TIMS). Results of preliminary RIMS investigations on a freshwater lake sediment sample are also discussed

  16. Galaxy Masses : A Review

    NARCIS (Netherlands)

    Courteau, Stephane; Cappellari, Michele; Jong, Roelof S. de; Dutton, Aaron A.; Koopmans, L.V.E.

    2013-01-01

    Galaxy masses play a fundamental role in our understanding of structure formation models. This review addresses the variety and reliability of mass estimators that pertain to stars, gas, and dark matter. The dierent sections on masses from stellar populations, dynamical masses of gas-rich and

  17. Reliability and validity of the brief multidimensional measure of religiousness/spirituality among adolescents.

    Science.gov (United States)

    Harris, Sion Kim; Sherritt, Lon R; Holder, David W; Kulig, John; Shrier, Lydia A; Knight, John R

    2008-12-01

    Developed for use in health research, the Brief Multidimensional Measure of Religiousness/Spirituality (BMMRS) consists of brief measures of a broad range of religiousness and spirituality (R/S) dimensions. It has established psychometric properties among adults, but little is known about its appropriateness for use with adolescents. We assessed the psychometric properties of the BMMRS among adolescents. We recruited a racially diverse (85% non-White) sample of 305 adolescents aged 12-18 years (median 16 yrs, IQR 14-17) from 3 urban medical clinics; 93 completed a retest 1 week later. We assessed internal consistency and test-retest reliability. We assessed construct validity by examining how well the measures discriminated groups expected to differ based on self-reported religious preference, and how they related to a hypothesized correlate, depressive symptoms. Religious preference was categorized into "No religion/Atheist" (11%), "Don't know/Confused" (9%), or "Named a religion" (80%). Responses to multi-item measures were generally internally consistent (alpha > or = 0.70 for 12/16 measures) and stable over 1 week (intraclass correlation coefficients > or = 0.70 for 14/16). Forgiveness, Negative R/S Coping, and Commitment items showed lower internal cohesiveness. Scores on most measures were higher (p Atheist" group. Forgiveness, Commitment, and Anticipated Support from members of one's congregation were inversely correlated with depressive symptoms, while BMMRS measures assessing negative R/S experiences (Negative R/S Coping, Negative Interactions with others in congregation, Loss in Faith) were positively correlated with depressive symptoms. These findings suggest that most BMMRS measures are reliable and valid for use among adolescents.

  18. The measurement of the W boson mass from CDF

    International Nuclear Information System (INIS)

    1994-06-01

    Recent results from LEP experiments have substantially improved the knowledge of the Z boson. However, hadron colliders remain the only source of direct measurements of the W boson. There have been measurements of the W boson mass from the UA2 and CDF collaborations. The W mass continues to be a subject of great interest in testing the Standard Model. Here, the authors have made a preliminary determination of the W boson mass M W = 80.38 ± 0.23 GeV/c 2 from a combined analysis of W → eν and W → μν in anti pp collisions at √s = 1.8 TeV. The electron data alone yields M W = 80.47 ± 0.15(stat.) ± 0.25(syst.) GeV/c 2 , while the muon data gives M W = 80.29 ± 0.20(stat.) ± 0.24(syst.) GeV/c 2

  19. Precision mass measurements of neutron-rich Co isotopes beyond N =40

    Science.gov (United States)

    Izzo, C.; Bollen, G.; Brodeur, M.; Eibach, M.; Gulyuz, K.; Holt, J. D.; Kelly, J. M.; Redshaw, M.; Ringle, R.; Sandler, R.; Schwarz, S.; Stroberg, S. R.; Sumithrarachchi, C. S.; Valverde, A. A.; Villari, A. C. C.

    2018-01-01

    The region near Z =28 and N =40 is a subject of great interest for nuclear structure studies due to spectroscopic signatures in 68Ni suggesting a subshell closure at N =40 . Trends in nuclear masses and their derivatives provide a complementary approach to shell structure investigations via separation energies. Penning trap mass spectrometry has provided precise measurements for a number of nuclei in this region; however, a complete picture of the mass surfaces has so far been limited by the large uncertainty remaining for nuclei with N >40 along the iron (Z =26 ) and cobalt (Z =27 ) chains because these species are not available from traditional isotope separator online rare isotope facilities. The Low-Energy Beam and Ion Trap Facility at the National Superconducting Cyclotron Laboratory is the first and only Penning trap mass spectrometer coupled to a fragmentation facility and therefore presents the unique opportunity to perform precise mass measurements of these elusive isotopes. Here we present the first Penning trap measurements of Co,6968, carried out at this facility. Some ambiguity remains as to whether the measured values are ground-state or isomeric-state masses. A detailed discussion is presented to evaluate this question and to motivate future work. In addition, we perform ab initio calculations of ground-state and two-neutron separation energies of cobalt isotopes with the valence-space in-medium similarity renormalization group approach based on a particular set of two- and three-nucleon forces that predict saturation in infinite matter. We discuss the importance of these measurements and calculations for understanding the evolution of nuclear structure near 68Ni.

  20. Measurement of the mass and width of the W boson

    CERN Document Server

    Abbiendi, G.; Akesson, P.F.; Alexander, G.; Anagnostou, G.; Anderson, K.J.; Asai, S.; Axen, D.; Bailey, I.; Barberio, E.; Barillari, T.; Barlow, R.J.; Batley, R.J.; Bechtle, P.; Behnke, T.; Bell, Kenneth Watson; Bell, P.J.; Bella, G.; Bellerive, A.; Benelli, G.; Bethke, S.; Biebel, O.; Boeriu, O.; Bock, P.; Boutemeur, M.; Braibant, S.; Brown, Robert M.; Burckhart, H.J.; Campana, S.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, D.G.; Ciocca, C.; Csilling, A.; Cuffiani, M.; Dado, S.; De Roeck, A.; De Wolf, E.A.; Desch, K.; Dienes, B.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Etzion, E.; Fabbri, F.; Ferrari, P.; Fiedler, F.; Fleck, I.; Ford, M.; Frey, A.; Gagnon, P.; Gary, John William; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Giunta, Marina; Goldberg, J.; Gross, E.; Grunhaus, J.; Gruwe, M.; Gunther, P.O.; Gupta, A.; Hajdu, C.; Hamann, M.; Hanson, G.G.; Harel, A.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herten, G.; Heuer, R.D.; Hill, J.C.; Horvath, D.; Igo-Kemenes, P.; Ishii, K.; Jeremie, H.; Jovanovic, P.; Junk, T.R.; Kanzaki, J.; Karlen, D.; Kawagoe, K.; Kawamoto, T.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kluth, S.; Kobayashi, T.; Kobel, M.; Komamiya, S.; Kramer, T.; Krasznahorkay, A.; Krieger, P.; von Krogh, J.; Kuhl, T.; Kupper, M.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Lellouch, D.; Letts, J.; Levinson, L.; Lillich, J.; Lloyd, S.L.; Loebinger, F.K.; Lu, J.; Ludwig, A.; Ludwig, J.; Mader, W.; Marcellini, S.; Martin, A.J.; Mashimo, T.; Mattig, Peter; McKenna, J.; McPherson, R.A.; Meijers, F.; Menges, W.; Merritt, F.S.; Mes, H.; Meyer, Niels T.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Mohr, W.; Mori, T.; Mutter, A.; Nagai, K.; Nakamura, I.; Nanjo, H.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oh, A.; Oreglia, M.J.; Orito, S.; Pahl, C.; Pasztor, G.; Pater, J.R.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Pooth, O.; Przybycien, M.; Quadt, A.; Rabbertz, K.; Rembser, C.; Renkel, P.; Roney, J.M.; Rossi, A.M.; Rozen, Y.; Runge, K.; Sachs, K.; Saeki, T.; Sarkisyan, E.K.G.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schorner-Sadenius, T.; Schroder, Matthias; Schumacher, M.; Seuster, R.; Shears, T.G.; Shen, B.C.; Sherwood, P.; Skuja, A.; Smith, A.M.; Sobie, R.; Soldner-Rembold, S.; Spano, F.; Stahl, A.; Strom, David M.; Strohmer, R.; Tarem, S.; Tasevsky, M.; Teuscher, R.; Thomson, M.A.; Torrence, E.; Toya, D.; Tran, P.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Ujvari, B.; Vollmer, C.F.; Vannerem, P.; Vertesi, R.; Verzocchi, M.; Voss, H.; Vossebeld, J.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wengler, T.; Wermes, N.; Wilson, G.W.; Wilson, J.A.; Wolf, G.; Wyatt, T.R.; Yamashita, S.; Zer-Zion, D.; Zivkovic, Lidija

    2006-01-01

    The mass and width of the W boson are measured using e+e- -> W+W- events from the data sample collected by the OPAL experiment at LEP at centre-of-mass energies between 170 GeV and 209 GeV. The mass (mw) and width (gw) are determined using direct reconstruction of the kinematics of W+W- -> qqbarlv and W+W- -> qqbarqqbar events. When combined with previous OPAL measurements using W+W- -> lvlv events and the dependence on mw of the WW production cross-section at threshold, the results are determined to be mw = 80.415 +- 0.042 +- 0.030 +- 0.009 GeV gw = 1.996 +- 0.096 +- 0.102 +- 0.003 GeV where the first error is statistical, the second systematic and the third due to uncertainties in the value of the LEP beam energy. By measuring mw with several different jet algorithms in the qqbarqqbar channel, a limit is also obtained on possible final-state interactions due to colour reconnection effects in W+W- -> qqbarqqbar events. The consistency of the results for the W mass and width with those inferred from other ele...

  1. Mercury mass measurement in fluorescent lamps via neutron activation analysis

    Science.gov (United States)

    Viererbl, L.; Vinš, M.; Lahodová, Z.; Fuksa, A.; Kučera, J.; Koleška, M.; Voljanskij, A.

    2015-11-01

    Mercury is an essential component of fluorescent lamps. Not all fluorescent lamps are recycled, resulting in contamination of the environment with toxic mercury, making measurement of the mercury mass used in fluorescent lamps important. Mercury mass measurement of lamps via instrumental neutron activation analysis (NAA) was tested under various conditions in the LVR-15 research reactor. Fluorescent lamps were irradiated in different positions in vertical irradiation channels and a horizontal channel in neutron fields with total fluence rates from 3×108 cm-2 s-1 to 1014 cm-2 s-1. The 202Hg(n,γ)203Hg nuclear reaction was used for mercury mass evaluation. Activities of 203Hg and others induced radionuclides were measured via gamma spectrometry with an HPGe detector at various times after irradiation. Standards containing an Hg2Cl2 compound were used to determine mercury mass. Problems arise from the presence of elements with a large effective cross section in luminescent material (europium, antimony and gadolinium) and glass (boron). The paper describes optimization of the NAA procedure in the LVR-15 research reactor with particular attention to influence of neutron self-absorption in fluorescent lamps.

  2. Top-quark mass measurement from dilepton events at CDF II.

    Science.gov (United States)

    Abulencia, A; Acosta, D; Adelman, J; Affolder, T; Akimoto, T; Albrow, M G; Ambrose, D; Amerio, S; Amidei, D; Anastassov, A; Anikeev, K; Annovi, A; Antos, J; Aoki, M; Apollinari, G; Arguin, J-F; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Azfar, F; Azzi-Bacchetta, P; Azzurri, P; Bacchetta, N; Bachacou, H; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Baroiant, S; Bartsch, V; Bauer, G; Bedeschi, F; Behari, S; Belforte, S; Bellettini, G; Bellinger, J; Belloni, A; Ben-Haim, E; Benjamin, D; Beretvas, A; Beringer, J; Berry, T; Bhatti, A; Binkley, M; Bisello, D; Bishai, M; Blair, R E; Blocker, C; Bloom, K; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bolshov, A; Bortoletto, D; Boudreau, J; Bourov, S; Boveia, A; Brau, B; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burkett, K; Busetto, G; Bussey, P; Byrum, K L; Cabrera, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carlsmith, D; Carosi, R; Carron, S; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chapman, J; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, I; Cho, K; Chokheli, D; Chou, J P; Chu, P H; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Ciljak, M; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Coca, M; Connolly, A; Convery, M E; Conway, J; Cooper, B; Copic, K; Cordelli, M; Cortiana, G; Cruz, A; Cuevas, J; Culbertson, R; Cyr, D; DaRonco, S; D'Auria, S; D'Onofrio, M; Dagenhart, D; de Barbaro, P; De Cecco, S; Deisher, A; De Lentdecker, G; Dell'Orso, M; Demers, S; Demortier, L; Deng, J; Deninno, M; De Pedis, D; Derwent, P F; Dionisi, C; Dittmann, J; Dituro, P; Dörr, C; Dominguez, A; Donati, S; Donega, M; Dong, P; Donini, J; Dorigo, T; Dube, S; Ebina, K; Efron, J; Ehlers, J; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, I; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Field, R; Flanagan, G; Flores-Castillo, L R; Foland, A; Forrester, S; Foster, G W; Franklin, M; Freeman, J C; Fujii, Y; Furic, I; Gajjar, A; Gallinaro, M; Galyardt, J; Garcia, J E; Garcia Sciverez, M; Garfinkel, A F; Gay, C; Gerberich, H; Gerchtein, E; Gerdes, D; Giagu, S; Giannetti, P; Gibson, A; Gibson, K; Ginsburg, C; Giolo, K; Giordani, M; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Goldstein, J; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Gotra, Y; Goulianos, K; Gresele, A; Griffiths, M; Grinstein, S; Grosso-Pilcher, C; Grundler, U; Guimaraes da Costa, J; Haber, C; Hahn, S R; Hahn, K; Halkiadakis, E; Hamilton, A; Han, B-Y; Handler, R; Happacher, F; Hara, K; Hare, M; Harper, S; Harr, R F; Harris, R M; Hatakeyama, K; Hauser, J; Hays, C; Hayward, H; Heijboer, A; Heinemann, B; Heinrich, J; Hennecke, M; Herndon, M; Heuser, J; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Holloway, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Huston, J; Ikado, K; Incandela, J; Introzzi, G; Iori, M; Ishizawa, Y; Ivanov, A; Iyutin, B; James, E; Jang, D; Jayatilaka, B; Jeans, D; Jensen, H; Jeon, E J; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kamon, T; Kang, J; Karagoz-Unel, M; Karchin, P E; Kato, Y; Kemp, Y; Kephart, R; Kerzel, U; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, M S; Kim, S B; Kim, S H; Kim, Y K; Kirby, M; Kirsch, L; Klimenko, S; Klute, M; Knuteson, B; Ko, B R; Kobayashi, H; Kondo, K; Kong, D J; Konigsberg, J; Kordas, K; Korytov, A; Kotwal, A V; Kovalev, A; Kraus, J; Kravchenko, I; Kreps, M; Kreymer, A; Kroll, J; Krumnack, N; Kruse, M; Krutelyov, V; Kuhlmann, S E; Kusakabe, Y; Kwang, S; Laasanen, A T; Lai, S; Lami, S; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Lecci, C; LeCompte, T; Lee, J; Lee, J; Lee, S W; Lefèvre, R; Leonardo, N; Leone, S; Levy, S; Lewis, J D; Li, K; Lin, C; Lin, C S; Lindgren, M; Lipeles, E; Liss, T M; Lister, A; Litvintsev, D O; Liu, T; Liu, Y; Lockyer, N S; Loginov, A; Loreti, M; Loverre, P; Lu, R-S; Lucchesi, D; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Lytken, E; Mack, P; MacQueen, D; Madrak, R; Maeshima, K; Maki, T; Maksimovic, P; Manca, G; Margaroli, F; Marginean, R; Marino, C; Martin, A; Martin, M; Martin, V; Martínez, M; Maruyama, T; Matsunaga, H; Mattson, M E; Mazini, R; Mazzanti, P; McFarland, K S; McGivern, D; McIntyre, P; McNamara, P; McNulty, R; Mehta, A; Menzemer, S; Menzione, A; Merkel, P; Mesropian, C; Messina, A; von der Mey, M; Miao, T; Miladinovic, N; Miles, J; Miller, R; Miller, J S; Mills, C; Milnik, M; Miquel, R; Miscetti, S; Mitselmakher, G; Miyamoto, A; Moggi, N; Mohr, B; Moore, R; Morello, M; Movilla Fernandez, P; Mülmenstädt, J; Mukherjee, A; Mulhearn, M; Muller, Th; Mumford, R; Murat, P; Nachtman, J; Nahn, S; Nakano, I; Napier, A; Naumov, D; Necula, V; Neu, C; Neubauer, M S; Nielsen, J; Nigmanov, T; Nodulman, L; Norniella, O; Ogawa, T; Oh, S H; Oh, Y D; Okusawa, T; Oldeman, R; Orava, R; Osterberg, K; Pagliarone, C; Palencia, E; Paoletti, R; Papadimitriou, V; Papikonomou, A; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Piedra, J; Pitts, K; Plager, C; Pondrom, L; Pope, G; Portell, X; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Rakitin, A; Rappoccio, S; Ratnikov, F; Reisert, B; Rekovic, V; van Remortel, N; Renton, P; Rescigno, M; Richter, S; Rimondi, F; Rinnert, K; Ristori, L; Robertson, W J; Robson, A; Rodrigo, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Rott, C; Ruiz, A; Russ, J; Rusu, V; Ryan, D; Saarikko, H; Sabik, S; Safonov, A; Sakumoto, W K; Salamanna, G; Salto, O; Saltzberg, D; Sanchez, C; Santi, L; Sarkar, S; Sato, K; Savard, P; Savoy-Navarro, A; Scheidle, T; Schlabach, P; Schmidt, E E; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scott, A L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Semeria, F; Sexton-Kennedy, L; Sfiligoi, I; Shapiro, M D; Shears, T; Shepard, P F; Sherman, D; Shimojima, M; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sill, A; Sinervo, P; Sisakyan, A; Sjolin, J; Skiba, A; Slaughter, A J; Sliwa, K; Smirnov, D; Smith, J R; Snider, F D; Snihur, R; Soderberg, M; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spinella, F; Squillacioti, P; Stanitzki, M; Staveris-Polykalas, A; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Stuart, D; Suh, J S; Sukhanov, A; Sumorok, K; Sun, H; Suzuki, T; Taffard, A; Tafirout, R; Takashima, R; Takeuchi, Y; Takikawa, K; Tanaka, M; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Tether, S; Thom, J; Thompson, A S; Thomson, E; Tipton, P; Tiwari, V; Tkaczyk, S; Toback, D; Tollefson, K; Tomura, T; Tonelli, D; Tönnesmann, M; Torre, S; Torretta, D; Tourneur, S; Trischuk, W; Tsuchiya, R; Tsuno, S; Turini, N; Ukegawa, F; Unverhau, T; Uozumi, S; Usynin, D; Vacavant, L; Vaiciulis, A; Vallecorsa, S; Varganov, A; Vataga, E; Velev, G; Veramendi, G; Veszpremi, V; Vickey, T; Vidal, R; Vila, I; Vilar, R; Vollrath, I; Volobouev, I; Würthwein, F; Wagner, P; Wagner, R G; Wagner, R L; Wagner, W; Wallny, R; Walter, T; Wan, Z; Wang, M J; Wang, S M; Warburton, A; Ward, B; Waschke, S; Waters, D; Watts, T; Weber, M; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Worm, S; Wright, T; Wu, X; Wynne, S M; Yagil, A; Yamamoto, K; Yamaoka, J; Yamashita, Y; Yang, C; Yang, U K; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zaw, I; Zetti, F; Zhang, X; Zhou, J; Zucchelli, S

    2006-04-21

    We report a measurement of the top-quark mass using events collected by the CDF II detector from pp collisions at square root of s = 1.96 TeV at the Fermilab Tevatron. We calculate a likelihood function for the top-quark mass in events that are consistent with tt --> bl(-)nu(l)bl'+ nu'(l) decays. The likelihood is formed as the convolution of the leading-order matrix element and detector resolution functions. The joint likelihood is the product of likelihoods for each of 33 events collected in 340 pb(-1) of integrated luminosity, yielding a top-quark mass M(t) = 165.2 +/- 6.1(stat) +/- 3.4(syst) GeV/c2. This first application of a matrix-element technique to tt --> bl+ nu(l)bl'- nu(l') decays gives the most precise single measurement of M(t) in dilepton events. Combined with other CDF run II measurements using dilepton events, we measure M(t) = 167.9 +/- 5.2(stat) +/- 3.7(syst) GeV/c2.

  3. Isometric and isokinetic muscle strength in the upper extremity can be reliably measured in persons with chronic stroke.

    Science.gov (United States)

    Ekstrand, Elisabeth; Lexell, Jan; Brogårdh, Christina

    2015-09-01

    To evaluate the test-retest reliability of isometric and isokinetic muscle strength measurements in the upper extremity after stroke. A test-retest design. Forty-five persons with mild to moderate paresis in the upper extremity > 6 months post-stroke. Isometric arm strength (shoulder abduction, elbow flexion), isokinetic arm strength (elbow extension/flexion) and isometric grip strength were measured with electronic dynamometers. Reliability was evaluated with intra-class correlation coefficients (ICC), changes in the mean, standard error of measurements (SEM) and smallest real differences (SRD). Reliability was high (ICCs: 0.92-0.97). The absolute and relative (%) SEM ranged from 2.7 Nm (5.6%) to 3.0 Nm (9.4%) for isometric arm strength, 2.6 Nm (7.4%) to 2.9 Nm (12.6%) for isokinetic arm strength, and 22.3 N (7.6%) to 26.4 N (9.2%) for grip strength. The absolute and relative (%) SRD ranged from 7.5 Nm (15.5%) to 8.4 Nm (26.1%) for isometric arm strength, 7.1 Nm (20.6%) to 8.0 Nm (34.8%) for isokinetic arm strength, and 61.8 N (21.0%) to 73.3 N (25.6%) for grip strength. Muscle strength in the upper extremity can be reliably measured in persons with chronic stroke. Isometric measurements yield smaller measurement errors than isokinetic measurements and might be preferred, but the choice depends on the research question.

  4. Is radiographic measurement of bony landmarks reliable for lateral meniscal sizing?

    Science.gov (United States)

    Yoon, Jung-Ro; Kim, Taik-Seon; Lim, Hong-Chul; Lim, Hyung-Tae; Yang, Jae-Hyuk

    2011-03-01

    The accuracy of meniscal measurement methods is still in debate. The authors' protocol for radiologic measurements will provide reproducible bony landmarks, and this measurement method of the lateral tibial plateau will correlate with the actual anatomic value. Controlled laboratory study. Twenty-five samples of fresh lateral meniscus with attached proximal tibia were obtained during total knee arthroplasty. Each sample was obtained without damage to the meniscus and bony attachment sites. The inclusion criterion was mild to moderate osteoarthritis in patients with mechanical axis deviation of less than 15°. Knees with lateral compartment osteoarthritic change or injured or degenerated menisci were excluded. For the lateral tibial plateau length measurements, the radiographic beam was angled 10° caudally at neutral rotation, which allowed differentiation of the lateral plateau cortical margins from the medial plateau. The transition points were identified and used for length measurement. The values of length were then compared with the conventional Pollard method and the anatomic values. The width measurement was done according to Pollard's protocol. For each knee, the percentage deviation from the anatomic dimension was recorded. Intraobserver error and interobserver error were calculated. The deviation of the authors' radiographic length measurements from anatomic dimensions was 1.4 ± 1.1 mm. The deviation of Pollard's radiographic length measurements was 4.1 ± 2.0 mm. With respect to accuracy-which represents the frequency of measurements that fall within 10% of measurements-the accuracy of authors' length was 98%, whereas for Pollard's method it was 40%. There was a good correlation between anatomic meniscal dimensions and each radiologic plateau dimensions for lateral meniscal width (R(2) = .790) and the authors' lateral meniscal length (R(2) = .823) and fair correlation for Pollard's lateral meniscal length (R(2) = .660). The reliability of each

  5. Reliability of Heterochromatic Flicker Photometry in Measuring Macular Pigment Optical Density among Preadolescent Children

    Directory of Open Access Journals (Sweden)

    Sasha M. McCorkle

    2015-10-01

    Full Text Available Macular pigment optical density (MPOD—assessed using customized heterochromatic flicker photometry (cHFP—is related to better cognition and brain lutein among adults. However, the reliability of MPOD assessed by cHFP has not been investigated in children. We assessed inter-session reliability of MPOD using modified cHFP. 7–10-year-olds (n = 66 underwent cHFP over 2 visits using 11 examiners. Reliability was also assessed in a subsample (n = 46 with only 2 examiners. Among all participants, there was no significant difference between the two sessions (p = 0.59—session 1: 0.61 ± 0.28; session 2: 0.62 ± 0.27. There was no significant difference in the MPOD of boys vs. girls (p = 0.56. There was a significant correlation between sessions (Y = 0.52x + 0.31; R2 = 0.29, p ≤ 0.005, with a reliability of 0.70 (Cronbach’s α. Among the subsample with 2 examiners, there was a significant correlation between sessions (Y = 0.54x + 0.31; R2 = 0.32, p < 0.005, with a reliability of 0.72 (Cronbach’s α. In conclusion, there is moderate reliability for modified cHFP to measure MPOD in preadolescents. These findings provide support for future studies aiming to conduct noninvasive assessments of retinal xanthophylls and study their association with cognition during childhood.

  6. Precision measurement of the mass difference between light nuclei and anti-nuclei

    CERN Document Server

    Adam, Jaroslav; Aggarwal, Madan Mohan; Aglieri Rinella, Gianluca; Agnello, Michelangelo; Agrawal, Neelima; Ahammed, Zubayer; Ahmed, Ijaz; Ahn, Sang Un; Aimo, Ilaria; Aiola, Salvatore; Ajaz, Muhammad; Akindinov, Alexander; Alam, Sk Noor; Aleksandrov, Dmitry; Alessandro, Bruno; Alexandre, Didier; Alfaro Molina, Jose Ruben; Alici, Andrea; Alkin, Anton; Alme, Johan; Alt, Torsten; Altinpinar, Sedat; Altsybeev, Igor; Alves Garcia Prado, Caio; Andrei, Cristian; Andronic, Anton; Anguelov, Venelin; Anielski, Jonas; Anticic, Tome; Antinori, Federico; Antonioli, Pietro; Aphecetche, Laurent Bernard; Appelshaeuser, Harald; Arcelli, Silvia; Armesto Perez, Nestor; Arnaldi, Roberta; Aronsson, Tomas; Arsene, Ionut Cristian; Arslandok, Mesut; Augustinus, Andre; Averbeck, Ralf Peter; Azmi, Mohd Danish; Bach, Matthias Jakob; Badala, Angela; Baek, Yong Wook; Bagnasco, Stefano; Bailhache, Raphaelle Marie; Bala, Renu; Baldisseri, Alberto; Ball, Markus; Baltasar Dos Santos Pedrosa, Fernando; Baral, Rama Chandra; Barbano, Anastasia Maria; Barbera, Roberto; Barile, Francesco; Barnafoldi, Gergely Gabor; Barnby, Lee Stuart; Ramillien Barret, Valerie; Bartalini, Paolo; Bartke, Jerzy Gustaw; Bartsch, Esther; Basile, Maurizio; Bastid, Nicole; Basu, Sumit; Bathen, Bastian; Batigne, Guillaume; Batista Camejo, Arianna; Batyunya, Boris; Batzing, Paul Christoph; Bearden, Ian Gardner; Beck, Hans; Bedda, Cristina; Behera, Nirbhay Kumar; Belikov, Iouri; Bellini, Francesca; Bello Martinez, Hector; Bellwied, Rene; Belmont Iii, Ronald John; Belmont Moreno, Ernesto; Belyaev, Vladimir; Bencedi, Gyula; Beole, Stefania; Berceanu, Ionela; Bercuci, Alexandru; Berdnikov, Yaroslav; Berenyi, Daniel; Bertens, Redmer Alexander; Berzano, Dario; Betev, Latchezar; Bhasin, Anju; Bhat, Inayat Rasool; Bhati, Ashok Kumar; Bhattacharjee, Buddhadeb; Bhom, Jihyun; Bianchi, Livio; Bianchi, Nicola; Bianchin, Chiara; Bielcik, Jaroslav; Bielcikova, Jana; Bilandzic, Ante; Biswas, Saikat; Bjelogrlic, Sandro; Blanco, Fernando; Blau, Dmitry; Blume, Christoph; Bock, Friederike; Bogdanov, Alexey; Boggild, Hans; Boldizsar, Laszlo; Bombara, Marek; Book, Julian Heinz; Borel, Herve; Borissov, Alexander; Borri, Marcello; Bossu, Francesco; Botje, Michiel; Botta, Elena; Boettger, Stefan; Braun-Munzinger, Peter; Bregant, Marco; Breitner, Timo Gunther; Broker, Theo Alexander; Browning, Tyler Allen; Broz, Michal; Brucken, Erik Jens; Bruna, Elena; Bruno, Giuseppe Eugenio; Budnikov, Dmitry; Buesching, Henner; Bufalino, Stefania; Buncic, Predrag; Busch, Oliver; Buthelezi, Edith Zinhle; Buxton, Jesse Thomas; Caffarri, Davide; Cai, Xu; Caines, Helen Louise; Calero Diaz, Liliet; Caliva, Alberto; Calvo Villar, Ernesto; Camerini, Paolo; Carena, Francesco; Carena, Wisla; Castillo Castellanos, Javier Ernesto; Castro, Andrew John; Casula, Ester Anna Rita; Cavicchioli, Costanza; Ceballos Sanchez, Cesar; Cepila, Jan; Cerello, Piergiorgio; Chang, Beomsu; Chapeland, Sylvain; Chartier, Marielle; Charvet, Jean-Luc Fernand; Chattopadhyay, Subhasis; Chattopadhyay, Sukalyan; Chelnokov, Volodymyr; Cherney, Michael Gerard; Cheshkov, Cvetan Valeriev; Cheynis, Brigitte; Chibante Barroso, Vasco Miguel; Dobrigkeit Chinellato, David; Chochula, Peter; Choi, Kyungeon; Chojnacki, Marek; Choudhury, Subikash; Christakoglou, Panagiotis; Christensen, Christian Holm; Christiansen, Peter; Chujo, Tatsuya; Chung, Suh-Urk; Cicalo, Corrado; Cifarelli, Luisa; Cindolo, Federico; Cleymans, Jean Willy Andre; Colamaria, Fabio Filippo; Colella, Domenico; Collu, Alberto; Colocci, Manuel; Conesa Balbastre, Gustavo; Conesa Del Valle, Zaida; Connors, Megan Elizabeth; Contreras Nuno, Jesus Guillermo; Cormier, Thomas Michael; Corrales Morales, Yasser; Cortes Maldonado, Ismael; Cortese, Pietro; Cosentino, Mauro Rogerio; Costa, Filippo; Crochet, Philippe; Cruz Albino, Rigoberto; Cuautle Flores, Eleazar; Cunqueiro Mendez, Leticia; Dahms, Torsten; Dainese, Andrea; Danu, Andrea; Das, Debasish; Das, Indranil; Das, Supriya; Dash, Ajay Kumar; Dash, Sadhana; De, Sudipan; De Caro, Annalisa; De Cataldo, Giacinto; De Cuveland, Jan; De Falco, Alessandro; De Gruttola, Daniele; De Marco, Nora; De Pasquale, Salvatore; Deisting, Alexander; Deloff, Andrzej; Denes, Ervin Sandor; D'Erasmo, Ginevra; Di Bari, Domenico; Di Mauro, Antonio; Di Nezza, Pasquale; Diaz Corchero, Miguel Angel; Dietel, Thomas; Dillenseger, Pascal; Divia, Roberto; Djuvsland, Oeystein; Dobrin, Alexandru Florin; Dobrowolski, Tadeusz Antoni; Domenicis Gimenez, Diogenes; Donigus, Benjamin; Dordic, Olja; Dubey, Anand Kumar; Dubla, Andrea; Ducroux, Laurent; Dupieux, Pascal; Ehlers Iii, Raymond James; Elia, Domenico; Engel, Heiko; Erazmus, Barbara Ewa; Erhardt, Filip; Eschweiler, Dominic; Espagnon, Bruno; Estienne, Magali Danielle; Esumi, Shinichi; Evans, David; Evdokimov, Sergey; Eyyubova, Gyulnara; Fabbietti, Laura; Fabris, Daniela; Faivre, Julien; Fantoni, Alessandra; Fasel, Markus; Feldkamp, Linus; Felea, Daniel; Feliciello, Alessandro; Feofilov, Grigorii; Ferencei, Jozef; Fernandez Tellez, Arturo; Gonzalez Ferreiro, Elena; Ferretti, Alessandro; Festanti, Andrea; Figiel, Jan; Araujo Silva Figueredo, Marcel; Filchagin, Sergey; Finogeev, Dmitry; Fionda, Fiorella; Fiore, Enrichetta Maria; Fleck, Martin Gabriel; Floris, Michele; Foertsch, Siegfried Valentin; Foka, Panagiota; Fokin, Sergey; Fragiacomo, Enrico; Francescon, Andrea; Frankenfeld, Ulrich Michael; Fuchs, Ulrich; Furget, Christophe; Furs, Artur; Fusco Girard, Mario; Gaardhoeje, Jens Joergen; Gagliardi, Martino; Gago Medina, Alberto Martin; Gallio, Mauro; Gangadharan, Dhevan Raja; Ganoti, Paraskevi; Gao, Chaosong; Garabatos Cuadrado, Jose; Garcia-Solis, Edmundo Javier; Gargiulo, Corrado; Gasik, Piotr Jan; Germain, Marie; Gheata, Andrei George; Gheata, Mihaela; Ghosh, Premomoy; Ghosh, Sanjay Kumar; Gianotti, Paola; Giubellino, Paolo; Giubilato, Piero; Gladysz-Dziadus, Ewa; Glassel, Peter; Gomez Ramirez, Andres; Gonzalez Zamora, Pedro; Gorbunov, Sergey; Gorlich, Lidia Maria; Gotovac, Sven; Grabski, Varlen; Graczykowski, Lukasz Kamil; Grelli, Alessandro; Grigoras, Alina Gabriela; Grigoras, Costin; Grigoryev, Vladislav; Grigoryan, Ara; Grigoryan, Smbat; Grynyov, Borys; Grion, Nevio; Grosse-Oetringhaus, Jan Fiete; Grossiord, Jean-Yves; Grosso, Raffaele; Guber, Fedor; Guernane, Rachid; Guerzoni, Barbara; Gulbrandsen, Kristjan Herlache; Gulkanyan, Hrant; Gunji, Taku; Gupta, Anik; Gupta, Ramni; Haake, Rudiger; Haaland, Oystein Senneset; Hadjidakis, Cynthia Marie; Haiduc, Maria; Hamagaki, Hideki; Hamar, Gergoe; Hanratty, Luke David; Hansen, Alexander; Harris, John William; Hartmann, Helvi; Harton, Austin Vincent; Hatzifotiadou, Despina; Hayashi, Shinichi; Heckel, Stefan Thomas; Heide, Markus Ansgar; Helstrup, Haavard; Herghelegiu, Andrei Ionut; Herrera Corral, Gerardo Antonio; Hess, Benjamin Andreas; Hetland, Kristin Fanebust; Hilden, Timo Eero; Hillemanns, Hartmut; Hippolyte, Boris; Hristov, Peter Zahariev; Huang, Meidana; Humanic, Thomas; Hussain, Nur; Hussain, Tahir; Hutter, Dirk; Hwang, Dae Sung; Ilkaev, Radiy; Ilkiv, Iryna; Inaba, Motoi; Ionita, Costin; Ippolitov, Mikhail; Irfan, Muhammad; Ivanov, Marian; Ivanov, Vladimir; Izucheev, Vladimir; Jacobs, Peter Martin; Jahnke, Cristiane; Jang, Haeng Jin; Janik, Malgorzata Anna; Pahula Hewage, Sandun; Jena, Chitrasen; Jena, Satyajit; Jimenez Bustamante, Raul Tonatiuh; Jones, Peter Graham; Jung, Hyungtaik; Jusko, Anton; Kalinak, Peter; Kalweit, Alexander Philipp; Kamin, Jason Adrian; Kang, Ju Hwan; Kaplin, Vladimir; Kar, Somnath; Karasu Uysal, Ayben; Karavichev, Oleg; Karavicheva, Tatiana; Karpechev, Evgeny; Kebschull, Udo Wolfgang; Keidel, Ralf; Keijdener, Darius Laurens; Keil, Markus; Khan, Kamal; Khan, Mohammed Mohisin; Khan, Palash; Khan, Shuaib Ahmad; Khanzadeev, Alexei; Kharlov, Yury; Kileng, Bjarte; Kim, Beomkyu; Kim, Do Won; Kim, Dong Jo; Kim, Hyeonjoong; Kim, Jinsook; Kim, Mimae; Kim, Minwoo; Kim, Se Yong; Kim, Taesoo; Kirsch, Stefan; Kisel, Ivan; Kiselev, Sergey; Kisiel, Adam Ryszard; Kiss, Gabor; Klay, Jennifer Lynn; Klein, Carsten; Klein, Jochen; Klein-Boesing, Christian; Kluge, Alexander; Knichel, Michael Linus; Knospe, Anders Garritt; Kobayashi, Taiyo; Kobdaj, Chinorat; Kofarago, Monika; Kohler, Markus Konrad; Kollegger, Thorsten; Kolozhvari, Anatoly; Kondratev, Valerii; Kondratyeva, Natalia; Kondratyuk, Evgeny; Konevskikh, Artem; Kouzinopoulos, Charalampos; Kovalenko, Vladimir; Kowalski, Marek; Kox, Serge; Koyithatta Meethaleveedu, Greeshma; Kral, Jiri; Kralik, Ivan; Kravcakova, Adela; Krelina, Michal; Kretz, Matthias; Krivda, Marian; Krizek, Filip; Kryshen, Evgeny; Krzewicki, Mikolaj; Kubera, Andrew Michael; Kucera, Vit; Kucheryaev, Yury; Kugathasan, Thanushan; Kuhn, Christian Claude; Kuijer, Paulus Gerardus; Kulakov, Igor; Kumar, Jitendra; Lokesh, Kumar; Kurashvili, Podist; Kurepin, Alexander; Kurepin, Alexey; Kuryakin, Alexey; Kushpil, Svetlana; Kweon, Min Jung; Kwon, Youngil; La Pointe, Sarah Louise; La Rocca, Paola; Lagana Fernandes, Caio; Lakomov, Igor; Langoy, Rune; Lara Martinez, Camilo Ernesto; Lardeux, Antoine Xavier; Lattuca, Alessandra; Laudi, Elisa; Lea, Ramona; Leardini, Lucia; Lee, Graham Richard; Lee, Seongjoo; Legrand, Iosif; Lehnert, Joerg Walter; Lemmon, Roy Crawford; Lenti, Vito; Leogrande, Emilia; Leon Monzon, Ildefonso; Leoncino, Marco; Levai, Peter; Li, Shuang; Li, Xiaomei; Lien, Jorgen Andre; Lietava, Roman; Lindal, Svein; Lindenstruth, Volker; Lippmann, Christian; Lisa, Michael Annan; Ljunggren, Hans Martin; Lodato, Davide Francesco; Lonne, Per-Ivar; Loggins, Vera Renee; Loginov, Vitaly; Loizides, Constantinos; Lopez, Xavier Bernard; Lopez Torres, Ernesto; Lowe, Andrew John; Lu, Xianguo; Luettig, Philipp Johannes; Lunardon, Marcello; Luparello, Grazia; Maevskaya, Alla; Mager, Magnus; Mahajan, Sanjay; Mahmood, Sohail Musa; Maire, Antonin; Majka, Richard Daniel; Malaev, Mikhail; Maldonado Cervantes, Ivonne Alicia; Malinina, Liudmila; Mal'Kevich, Dmitry; Malzacher, Peter; Mamonov, Alexander; Manceau, Loic Henri Antoine; Manko, Vladislav; Manso, Franck; Manzari, Vito; Marchisone, Massimiliano; Mares, Jiri; Margagliotti, Giacomo Vito; Margotti, Anselmo; Margutti, Jacopo; Marin, Ana Maria; Markert, Christina; Marquard, Marco; Martashvili, Irakli; Martin, Nicole Alice; Martin Blanco, Javier; Martinengo, Paolo; Martinez Hernandez, Mario Ivan; Martinez-Garcia, Gines; Martinez Pedreira, Miguel; Martynov, Yevgen; Mas, Alexis Jean-Michel; Masciocchi, Silvia; Masera, Massimo; Masoni, Alberto; Massacrier, Laure Marie; Mastroserio, Annalisa; Matyja, Adam Tomasz; Mayer, Christoph; Mazer, Joel Anthony; Mazzoni, Alessandra Maria; Mcdonald, Daniel; Meddi, Franco; Menchaca-Rocha, Arturo Alejandro; Meninno, Elisa; Mercado-Perez, Jorge; Meres, Michal; Miake, Yasuo; Mieskolainen, Matti Mikael; Mikhaylov, Konstantin; Milano, Leonardo; Milosevic, Jovan; Minervini, Lazzaro Manlio; Mischke, Andre; Mishra, Aditya Nath; Miskowiec, Dariusz Czeslaw; Mitra, Jubin; Mitu, Ciprian Mihai; Mohammadi, Naghmeh; Mohanty, Bedangadas; Molnar, Levente; Montano Zetina, Luis Manuel; Montes Prado, Esther; Morando, Maurizio; Moreira De Godoy, Denise Aparecida; Moretto, Sandra; Morreale, Astrid; Morsch, Andreas; Muccifora, Valeria; Mudnic, Eugen; Muhlheim, Daniel Michael; Muhuri, Sanjib; Mukherjee, Maitreyee; Muller, Hans; Mulligan, James Declan; Gameiro Munhoz, Marcelo; Murray, Sean; Musa, Luciano; Musinsky, Jan; Nandi, Basanta Kumar; Nania, Rosario; Nappi, Eugenio; Naru, Muhammad Umair; Nattrass, Christine; Nayak, Kishora; Nayak, Tapan Kumar; Nazarenko, Sergey; Nedosekin, Alexander; Nellen, Lukas; Ng, Fabian; Nicassio, Maria; Niculescu, Mihai; Niedziela, Jeremi; Nielsen, Borge Svane; Nikolaev, Sergey; Nikulin, Sergey; Nikulin, Vladimir; Noferini, Francesco; Nomokonov, Petr; Nooren, Gerardus; Norman, Jaime; Nyanin, Alexander; Nystrand, Joakim Ingemar; Oeschler, Helmut Oskar; Oh, Saehanseul; Oh, Sun Kun; Ohlson, Alice Elisabeth; Okatan, Ali; Okubo, Tsubasa; Olah, Laszlo; Oleniacz, Janusz; Oliveira Da Silva, Antonio Carlos; Oliver, Michael Henry; Onderwaater, Jacobus; Oppedisano, Chiara; Ortiz Velasquez, Antonio; Oskarsson, Anders Nils Erik; Otwinowski, Jacek Tomasz; Oyama, Ken; Ozdemir, Mahmut; Pachmayer, Yvonne Chiara; Pagano, Paola; Paic, Guy; Pajares Vales, Carlos; Pal, Susanta Kumar; Pan, Jinjin; Pandey, Ashutosh Kumar; Pant, Divyash; Papikyan, Vardanush; Pappalardo, Giuseppe; Pareek, Pooja; Park, Woojin; Parmar, Sonia; Passfeld, Annika; Paticchio, Vincenzo; Paul, Biswarup; Pawlak, Tomasz Jan; Peitzmann, Thomas; Pereira Da Costa, Hugo Denis Antonio; Pereira De Oliveira Filho, Elienos; Peresunko, Dmitry Yurevich; Perez Lara, Carlos Eugenio; Peskov, Vladimir; Pestov, Yury; Petracek, Vojtech; Petrov, Viacheslav; Petrovici, Mihai; Petta, Catia; Piano, Stefano; Pikna, Miroslav; Pillot, Philippe; Pinazza, Ombretta; Pinsky, Lawrence; Piyarathna, Danthasinghe; Ploskon, Mateusz Andrzej; Planinic, Mirko; Pluta, Jan Marian; Pochybova, Sona; Podesta Lerma, Pedro Luis Manuel; Poghosyan, Martin; Polishchuk, Boris; Poljak, Nikola; Poonsawat, Wanchaloem; Pop, Amalia; Porteboeuf, Sarah Julie; Porter, R Jefferson; Pospisil, Jan; Prasad, Sidharth Kumar; Preghenella, Roberto; Prino, Francesco; Pruneau, Claude Andre; Pshenichnov, Igor; Puccio, Maximiliano; Puddu, Giovanna; Pujahari, Prabhat Ranjan; Punin, Valery; Putschke, Jorn Henning; Qvigstad, Henrik; Rachevski, Alexandre; Raha, Sibaji; Rajput, Sonia; Rak, Jan; Rakotozafindrabe, Andry Malala; Ramello, Luciano; Raniwala, Rashmi; Raniwala, Sudhir; Rasanen, Sami Sakari; Rascanu, Bogdan Theodor; Rathee, Deepika; Razazi, Vahedeh; Read, Kenneth Francis; Real, Jean-Sebastien; Redlich, Krzysztof; Reed, Rosi Jan; Rehman, Attiq Ur; Reichelt, Patrick Simon; Reicher, Martijn; Reidt, Felix; Ren, Xiaowen; Renfordt, Rainer Arno Ernst; Reolon, Anna Rita; Reshetin, Andrey; Rettig, Felix Vincenz; Revol, Jean-Pierre; Reygers, Klaus Johannes; Riabov, Viktor; Ricci, Renato Angelo; Richert, Tuva Ora Herenui; Richter, Matthias Rudolph; Riedler, Petra; Riegler, Werner; Riggi, Francesco; Ristea, Catalin-Lucian; Rivetti, Angelo; Rocco, Elena; Rodriguez Cahuantzi, Mario; Rodriguez Manso, Alis; Roeed, Ketil; Rogochaya, Elena; Rohr, David Michael; Roehrich, Dieter; Romita, Rosa; Ronchetti, Federico; Ronflette, Lucile; Rosnet, Philippe; Rossi, Andrea; Roukoutakis, Filimon; Roy, Ankhi; Roy, Christelle Sophie; Roy, Pradip Kumar; Rubio Montero, Antonio Juan; Rui, Rinaldo; Russo, Riccardo; Ryabinkin, Evgeny; Ryabov, Yury; Rybicki, Andrzej; Sadovskiy, Sergey; Safarik, Karel; Sahlmuller, Baldo; Sahoo, Pragati; Sahoo, Raghunath; Sahoo, Sarita; Sahu, Pradip Kumar; Saini, Jogender; Sakai, Shingo; Saleh, Mohammad Ahmad; Salgado Lopez, Carlos Alberto; Salzwedel, Jai Samuel Nielsen; Sambyal, Sanjeev Singh; Samsonov, Vladimir; Sanchez Castro, Xitzel; Sandor, Ladislav; Sandoval, Andres; Sano, Masato; Santagati, Gianluca; Sarkar, Debojit; Scapparone, Eugenio; Scarlassara, Fernando; Scharenberg, Rolf Paul; Schiaua, Claudiu Cornel; Schicker, Rainer Martin; Schmidt, Christian Joachim; Schmidt, Hans Rudolf; Schuchmann, Simone; Schukraft, Jurgen; Schulc, Martin; Schuster, Tim Robin; Schutz, Yves Roland; Schwarz, Kilian Eberhard; Schweda, Kai Oliver; Scioli, Gilda; Scomparin, Enrico; Scott, Rebecca Michelle; Seeder, Karin Soraya; Seger, Janet Elizabeth; Sekiguchi, Yuko; Selyuzhenkov, Ilya; Senosi, Kgotlaesele; Seo, Jeewon; Serradilla Rodriguez, Eulogio; Sevcenco, Adrian; Shabanov, Arseniy; Shabetai, Alexandre; Shadura, Oksana; Shahoyan, Ruben; Shangaraev, Artem; Sharma, Ankita; Sharma, Natasha; Shigaki, Kenta; Shtejer Diaz, Katherin; Sibiryak, Yury; Siddhanta, Sabyasachi; Sielewicz, Krzysztof Marek; Siemiarczuk, Teodor; Silvermyr, David Olle Rickard; Silvestre, Catherine Micaela; Simatovic, Goran; Simonetti, Giuseppe; Singaraju, Rama Narayana; Singh, Ranbir; Singha, Subhash; Singhal, Vikas; Sinha, Bikash; Sarkar - Sinha, Tinku; Sitar, Branislav; Sitta, Mario; Skaali, Bernhard; Slupecki, Maciej; Smirnov, Nikolai; Snellings, Raimond; Snellman, Tomas Wilhelm; Soegaard, Carsten; Soltz, Ron Ariel; Song, Jihye; Song, Myunggeun; Song, Zixuan; Soramel, Francesca; Sorensen, Soren Pontoppidan; Spacek, Michal; Spiriti, Eleuterio; Sputowska, Iwona Anna; Spyropoulou-Stassinaki, Martha; Srivastava, Brijesh Kumar; Stachel, Johanna; Stan, Ionel; Stefanek, Grzegorz; Steinpreis, Matthew Donald; Stenlund, Evert Anders; Steyn, Gideon Francois; Stiller, Johannes Hendrik; Stocco, Diego; Strmen, Peter; Alarcon Do Passo Suaide, Alexandre; Sugitate, Toru; Suire, Christophe Pierre; Suleymanov, Mais Kazim Oglu; Sultanov, Rishat; Sumbera, Michal; Symons, Timothy; Szabo, Alexander; Szanto De Toledo, Alejandro; Szarka, Imrich; Szczepankiewicz, Adam; Szymanski, Maciej Pawel; Takahashi, Jun; Tanaka, Naoto; Tangaro, Marco-Antonio; Tapia Takaki, Daniel Jesus; Tarantola Peloni, Attilio; Tariq, Mohammad; Tarzila, Madalina-Gabriela; Tauro, Arturo; Tejeda Munoz, Guillermo; Telesca, Adriana; Terasaki, Kohei; Terrevoli, Cristina; Teyssier, Boris; Thaeder, Jochen Mathias; Thomas, Deepa; Tieulent, Raphael Noel; Timmins, Anthony Robert; Toia, Alberica; Trogolo, Stefano; Trubnikov, Victor; Trzaska, Wladyslaw Henryk; Tsuji, Tomoya; Tumkin, Alexandr; Turrisi, Rosario; Tveter, Trine Spedstad; Ullaland, Kjetil; Uras, Antonio; Usai, Gianluca; Utrobicic, Antonija; Vajzer, Michal; Vala, Martin; Valencia Palomo, Lizardo; Vallero, Sara; Van Der Maarel, Jasper; Van Hoorne, Jacobus Willem; Van Leeuwen, Marco; Vanat, Tomas; Vande Vyvre, Pierre; Varga, Dezso; Diozcora Vargas Trevino, Aurora; Vargyas, Marton; Varma, Raghava; Vasileiou, Maria; Vasiliev, Andrey; Vauthier, Astrid; Vechernin, Vladimir; Veen, Annelies Marianne; Veldhoen, Misha; Velure, Arild; Venaruzzo, Massimo; Vercellin, Ermanno; Vergara Limon, Sergio; Vernet, Renaud; Verweij, Marta; Vickovic, Linda; Viesti, Giuseppe; Viinikainen, Jussi Samuli; Vilakazi, Zabulon; Villalobos Baillie, Orlando; Vinogradov, Alexander; Vinogradov, Leonid; Vinogradov, Yury; Virgili, Tiziano; Vislavicius, Vytautas; Viyogi, Yogendra; Vodopyanov, Alexander; Volkl, Martin Andreas; Voloshin, Kirill; Voloshin, Sergey; Volpe, Giacomo; Von Haller, Barthelemy; Vorobyev, Ivan; Vranic, Danilo; Vrlakova, Janka; Vulpescu, Bogdan; Vyushin, Alexey; Wagner, Boris; Wagner, Jan; Wang, Hongkai; Wang, Mengliang; Wang, Yifei; Watanabe, Daisuke; Weber, Michael; Weber, Steffen Georg; Wessels, Johannes Peter; Westerhoff, Uwe; Wiechula, Jens; Wikne, Jon; Wilde, Martin Rudolf; Wilk, Grzegorz Andrzej; Wilkinson, Jeremy John; Williams, Crispin; Windelband, Bernd Stefan; Winn, Michael Andreas; Yaldo, Chris G; Yamaguchi, Yorito; Yang, Hongyan; Yang, Ping; Yano, Satoshi; Yasnopolskiy, Stanislav; Yin, Zhongbao; Yokoyama, Hiroki; Yoo, In-Kwon; Yurchenko, Volodymyr; Yushmanov, Igor; Zaborowska, Anna; Zaccolo, Valentina; Zaman, Ali; Zampolli, Chiara; Correia Zanoli, Henrique Jose; Zaporozhets, Sergey; Zarochentsev, Andrey; Zavada, Petr; Zavyalov, Nikolay; Zbroszczyk, Hanna Paulina; Zgura, Sorin Ion; Zhalov, Mikhail; Zhang, Haitao; Zhang, Xiaoming; Zhang, Yonghong; Zhao, Chengxin; Zhigareva, Natalia; Zhou, Daicui; Zhou, You; Zhou, Zhuo; Zhu, Hongsheng; Zhu, Jianhui; Zhu, Xiangrong; Zichichi, Antonino; Zimmermann, Alice; Zimmermann, Markus Bernhard; Zinovjev, Gennady; Zyzak, Maksym

    2015-08-17

    The measurement of the mass differences for systems bound by the strong force has reached a very high precision with protons and anti-protons. The extension of such measurement from (anti-)baryons to (anti-)nuclei allows one to probe any difference in the interactions between nucleons and anti-nucleons encoded in the (anti-)nuclei masses. This force is a remnant of the underlying strong interaction among quarks and gluons and can be described by effective theories, but cannot yet be directly derived from quantum chromodynamics. Here we report a measurement of the difference between the ratios of the mass and charge of deuterons (d) and anti-deuterons ($\\bar{d}$), and $^{3}{\\rm He}$ and $^3\\overline{\\rm He}$ nuclei carried out with the ALICE (A Large Ion Collider Experiment) detector in Pb-Pb collisions at a centre-of-mass energy per nucleon pair of 2.76 TeV. Our direct measurement of the mass-over-charge differences confirm CPT invariance to an unprecedented precision in the sector of light nuclei. This funda...

  7. LEAD SLOWING DOWN SPECTROSCOPY FOR DIRECT Pu MASS MEASUREMENTS

    International Nuclear Information System (INIS)

    Ressler, Jennifer J.; Smith, Leon E.; Anderson, Kevin K.

    2008-01-01

    The direct measurement of Pu in previously irradiated fuel assemblies is a recognized need in the international safeguards community. A suitable technology could support more timely and independent material control and accounting (MC and A) measurements at nuclear fuel storage areas, the head-end of reprocessing facilities, and at the product-end of recycled fuel fabrication. Lead slowing down spectroscopy (LSDS) may be a viable solution for directly measuring not only the mass of 239Pu in fuel assemblies, but also the masses of other fissile isotopes such as 235U and 241Pu. To assess the potential viability of LSDS, an LSDS spectrometer was modeled in MCNP5 and 'virtual assays' of nominal PWR assemblies ranging from 0 to 60 GWd/MTU burnup were completed. Signal extraction methods, including the incorporation of nonlinear fitting to account for self-shielding effects in strong resonance regions, are described. Quantitative estimates of Pu uncertainty are given for simplistic and more realistic fuel isotopic inventories calculated using ORIGEN. A discussion of additional signal-perturbing effects that will be addressed in future work, and potential signal extraction approaches that could improve Pu mass uncertainties, are also discussed

  8. Cylinder with differential piston for mass measurements

    Energy Technology Data Exchange (ETDEWEB)

    Bordeaşu, I.; Bălăşoiu, V. [Universitatea Politehnica din Timişoara, Timosoara (Romania); Hadă, A. [UniversitateaPolitehnicaBucureşti, Bucureşti (Romania); Popoviciu, M. [Academy of Romanian ScientistsTimişoara Branch (Romania)

    2007-07-01

    The paper presents a cylinder with differential piston, adapted for measuring the weight of fixed objects such as: fuel tanks (regardless of their capacity), bunkers and silos for all kind of materials, or mobile objects such as: automobiles, trucks, locomotives and railway cars. Although, the cylinder with differential piston is used on a large scale in hydraulic drive or hydraulic control circuits, till now it was not used as constituent part for weight measurements devices. The novelty of the present paper is precisely the use of the device for such purposes. Based on a computation algorithm, the paper presents the general design (assembly), of the device used for weighing important masses (1…. 100 tones). The fundamental idea consist in the fact that, a mass over 10 tones may be weighted with a helicoidally spring subjected to an axial force between 0 and 3000 N, with a deflection of about 30 mm. Simultaneously with the mechanical part, the electronic recording system is also described. The great advantage of the presented device consist in the fact that it can be used in heavy polluted atmosphere or difficult topographic conditions as a result of both the small dimensions and the protection systems adopted. Keywords: cylinder hydraulic with differential piston, hydrostatic pressure, measuring devices.

  9. Measurement of the Top Quark Mass Simultaneously in Dilepton and Lepton + Jets Decay Channels

    Energy Technology Data Exchange (ETDEWEB)

    Fedorko, Wojciech T. [Univ. of Chicago, IL (United States)

    2008-12-01

    The authors present the first measurement of the top quark mass using simultaneously data from two decay channels. They use a data sample of √s = 1.96 TeV collisions with integrated luminosity of 1.9 fb-1 collected by the CDF II detector. They select dilepton and lepton + jets channel decays of t$\\bar{t}$ pairs and reconstruct two observables in each topology. They use non-parametric techniques to derive probability density functions from simulated signal and background samples. The observables are the reconstructed top quark mass and the scalar sum of transverse energy of the event in the dilepton topology and the reconstructed top quark mass and the invariant mass of jets from the W boson decay in lepton + jets channel. They perform a simultaneous fit for the top quark mass and the jet energy scale which is constrained in situ by the hadronic W boson resonance from the lepton + jets channel. Using 144 dilepton candidate events and 332 lepton + jets candidate events they measure: Mtop = 171.9 ± 1.7 (stat. + JES) ± 1.1 (other sys.) GeV/c2 = 171.9 ± 2.0 GeV/c2. The measurement features a robust treatment of the systematic uncertainties, correlated between the two channels and develops techniques for a future top quark mass measurement simultaneously in all decay channels. Measurements of the W boson mass and the top quark mass provide a constraint on the mass of the yet unobserved Higgs boson. The Higgs boson mass implied by measurement presented here is higher than Higgs boson mass implied by previously published, most precise CDF measurements of the top quark mass in lepton + jets and dilepton channels separately.

  10. Measurements of the W boson mass at the Tevatron

    International Nuclear Information System (INIS)

    Hays, C.P.

    2014-01-01

    Precise measurements of the W boson mass W test the contributions of loop corrections to the W boson propagator from e.g. the top and bottom quarks and the Higgs boson. New measurements from CDF [m W =80.387±0.012(stat)±0.015(syst) GeV] and D0 [m W =80.375±0.011(stat)±0.020(syst) GeV] are the most precise to date, significantly tightening the constraints on loops in the W boson propagator. The new world-average value of the W boson mass is m W =80.385±0.015 GeV. (author)

  11. Validity and Reliability of a New Device (WIMU®) for Measuring Hamstring Muscle Extensibility.

    Science.gov (United States)

    Muyor, José M

    2017-09-01

    The aims of the current study were 1) to evaluate the validity of the WIMU ® system for measuring hamstring muscle extensibility in the passive straight leg raise (PSLR) test using an inclinometer for the criterion and 2) to determine the test-retest reliability of the WIMU ® system to measure hamstring muscle extensibility during the PSLR test. 55 subjects were evaluated on 2 separate occasions. Data from a Unilever inclinometer and WIMU ® system were collected simultaneously. Intraclass correlation coefficients (ICCs) for the validity were very high (0.983-1); a very low systematic bias (-0.21°--0.42°), random error (0.05°-0.04°) and standard error of the estimate (0.43°-0.34°) were observed (left-right leg, respectively) between the 2 devices (inclinometer and the WIMU ® system). The R 2 between the devices was 0.999 (p<0.001) in both the left and right legs. The test-retest reliability of the WIMU ® system was excellent, with ICCs ranging from 0.972-0.995, low coefficients of variation (0.01%), and a low standard error of the estimate (0.19-0.31°). The WIMU ® system showed strong concurrent validity and excellent test-retest reliability for the evaluation of hamstring muscle extensibility in the PSLR test. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Test–Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study

    Directory of Open Access Journals (Sweden)

    Clare E. Palmer

    2018-01-01

    Full Text Available Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington’s disease (HD and Parkinson’s disease (PD across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test–retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test–retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test–retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT from the combined-Simon-Stop-Signal task showed moderate test–retest reliability, however, the combined SSRT interference effect showed poor test–retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  13. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    Science.gov (United States)

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  14. Reliability of a new method for measuring coronal trunk imbalance, the axis-line-angle technique.

    Science.gov (United States)

    Zhang, Rui-Fang; Liu, Kun; Wang, Xue; Liu, Qian; He, Jia-Wei; Wang, Xiang-Yang; Yan, Zhi-Han

    2015-12-01

    Accurate determination of the extent of trunk imbalance in the coronal plane plays a key role in an evaluation of patients with trunk imbalance, such as patients with adolescent idiopathic scoliosis. An established, widely used practice in evaluating trunk imbalance is to drop a plumb line from the C7 vertebra to a key reference axis, the central sacral vertical line (CSVL) in full-spine standing anterioposterior radiographs, and measuring the distance between them, the C7-CSVL. However, measuring the CSVL is subject to intraobserver differences, is error-prone, and is of poor reliability. Therefore, the development of a different way to measure trunk imbalance is needed. This study aimed to describe a new method to measure coronal trunk imbalance, the axis-line-angle technique (ALAT), which measures the angle at the intersection between the C7 plumb line and an axis line drawn from the vertebral centroid of the C7 to the middle of the superior border of the symphysis pubis, and to compare the reliability of the ALAT with that of the C7-CSVL. A prospective study at a university hospital was used. The patient sample consisted of sixty-nine consecutively enrolled men and women patients, aged 10-18 years, who had trunk imbalance defined as C7-CSVL longer than 20 mm on computed full-spine standing anterioposterior radiographs. Data were analyzed to determine the correlation between C7-CSVL and ALAT measurements and to determine intraobserver and interobserver reliabilities. Using a picture archiving and communication system, three radiologists independently evaluated trunk imbalance on the 69 computed radiographs by measuring the C7-CSVL and by measuring the angle determined by the ALAT. Data were analyzed to determine the correlations between the two measures of trunk imbalance, and to determine intraobserver and interobserver reliabilities of each of them. Overall results from the measurements by the C7-CSVL and the ALAT were significantly moderately correlated

  15. Is a sphygmomanometer a valid and reliable tool to measure the isometric strength of hip muscles? A systematic review.

    Science.gov (United States)

    Toohey, Liam Anthony; De Noronha, Marcos; Taylor, Carolyn; Thomas, James

    2015-02-01

    Muscle strength measurement is a key component of physiotherapists' assessment and is frequently used as an outcome measure. A sphygmomanometer is an instrument commonly used to measure blood pressure that can be potentially used as a tool to assess isometric muscle strength. To systematically review the evidence on the reliability and validity of a sphygmomanometer for measuring isometric strength of hip muscles. A literature search was conducted across four databases. Studies were eligible if they presented data on reliability and/or validity, used a sphygmomanometer to measure isometric muscle strength of the hip region, and were peer reviewed. The individual studies were evaluated for quality using a standardized critical appraisal tool. A total of 644 articles were screened for eligibility, with five articles chosen for inclusion. The use of a sphygmomanometer to objectively assess isometric muscle strength of the hip muscles appears to be reliable with intraclass correlation coefficient values ranging from 0.66 to 0.94 in elderly and young populations. No studies were identified that have assessed the validity of a sphygmomanometer. The sphygmomanometer appears to be reliable for assessment of isometric muscle strength around the hip joint, but further research is warranted to establish its validity.

  16. Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study

    Directory of Open Access Journals (Sweden)

    Leila Rahnama

    2015-08-01

    Full Text Available OBJECTIVES: This study was conducted with the purpose of evaluating the inter-session reliability of new software to measure the diameters of the cervical multifidus muscle (CMM, both at rest and during isometric contractions of the shoulder abductors in subjects with neck pain and in healthy individuals.METHOD: In the present study, the reliability of measuring the diameters of the CMM with the Sonosynch software was evaluated by using 24 participants, including 12 subjects with chronic neck pain and 12 healthy individuals. The anterior-posterior diameter (APD and the lateral diameter (LD of the CMM were measured in a resting state and then repeated during isometric contraction of the shoulder abductors. Measurements were taken on separate occasions 3 to 7 days apart in order to determine inter-session reliability. Intraclass correlation coefficient (ICC, standard error of measurement (SEM, and smallest detectable difference (SDD were used to evaluate the relative and absolute reliability, respectively.RESULTS: The Sonosynch software has shown to be highly reliable in measuring the diameters of the CMM both in healthy subjects and in those with neck pain. The ICCs 95% CI for APD ranged from 0.84 to 0.94 in subjects with neck pain and from 0.86 to 0.94 in healthy subjects. For LD, the ICC 95% CI ranged from 0.64 to 0.95 in subjects with neck pain and from 0.82 to 0.92 in healthy subjects.CONCLUSIONS: Ultrasonographic measurement of the diameters of the CMM using Sonosynch has proved to be reliable especially for APD in healthy subjects as well as subjects with neck pain.

  17. Detecting rapid mass movements using electrical self-potential measurements

    Science.gov (United States)

    Heinze, Thomas; Limbrock, Jonas; Pudasaini, Shiva P.; Kemna, Andreas

    2017-04-01

    Rapid mass movements are a latent danger for lives and infrastructure in almost any part of the world. Often such mass movements are caused by increasing pore pressure, for example, landslides after heavy rainfall or dam breaking after intrusion of water in the dam. Among several other geophysical methods used to observe water movement, the electrical self-potential method has been applied to a broad range of monitoring studies, especially focusing on volcanism and dam leakage but also during hydraulic fracturing and for earthquake prediction. Electrical self-potential signals may be caused by various mechanisms. Though, the most relevant source of the self-potential field in the given context is the streaming potential, caused by a flowing electrolyte through porous media with electrically charged internal surfaces. So far, existing models focus on monitoring water flow in non-deformable porous media. However, as the self-potential is sensitive to hydraulic parameters of the soil, any change in these parameters will cause an alteration of the electric signal. Mass movement will significantly influence the hydraulic parameters of the solid as well as the pressure field, assuming that fluid movement is faster than the pressure diffusion. We will present results of laboratory experiments under drained and undrained conditions with fluid triggered as well as manually triggered mass movements, monitored with self-potential measurements. For the undrained scenarios, we observe a clear correlation between the mass movements and signals in the electric potential, which clearly differ from the underlying potential variations due to increased saturation and fluid flow. In the drained experiments, we do not observe any measurable change in the electric potential. We therefore assume that change in fluid properties and release of the load causes disturbances in flow and streaming potential. We will discuss results of numerical simulations reproducing the observed effect. Our

  18. Measuring reliable change in cognition using the Edinburgh Cognitive and Behavioural ALS Screen (ECAS).

    Science.gov (United States)

    Crockford, Christopher; Newton, Judith; Lonergan, Katie; Madden, Caoifa; Mays, Iain; O'Sullivan, Meabhdh; Costello, Emmet; Pinto-Grau, Marta; Vajda, Alice; Heverin, Mark; Pender, Niall; Al-Chalabi, Ammar; Hardiman, Orla; Abrahams, Sharon

    2018-02-01

    Cognitive impairment affects approximately 50% of people with amyotrophic lateral sclerosis (ALS). Research has indicated that impairment may worsen with disease progression. The Edinburgh Cognitive and Behavioural ALS Screen (ECAS) was designed to measure neuropsychological functioning in ALS, with its alternate forms (ECAS-A, B, and C) allowing for serial assessment over time. The aim of the present study was to establish reliable change scores for the alternate forms of the ECAS, and to explore practice effects and test-retest reliability of the ECAS's alternate forms. Eighty healthy participants were recruited, with 57 completing two and 51 completing three assessments. Participants were administered alternate versions of the ECAS serially (A-B-C) at four-month intervals. Intra-class correlation analysis was employed to explore test-retest reliability, while analysis of variance was used to examine the presence of practice effects. Reliable change indices (RCI) and regression-based methods were utilized to establish change scores for the ECAS alternate forms. Test-retest reliability was excellent for ALS Specific, ALS Non-Specific, and ECAS Total scores of the combined ECAS A, B, and C (all > .90). No significant practice effects were observed over the three testing sessions. RCI and regression-based methods produced similar change scores. The alternate forms of the ECAS possess excellent test-retest reliability in a healthy control sample, with no significant practice effects. The use of conservative RCI scores is recommended. Therefore, a change of ≥8, ≥4, and ≥9 for ALS Specific, ALS Non-Specific, and ECAS Total score is required for reliable change.

  19. Reliability of the Star Excursion Balance Test and Two New Similar Protocols to Measure Trunk Postural Control.

    Science.gov (United States)

    López-Plaza, Diego; Juan-Recio, Casto; Barbado, David; Ruiz-Pérez, Iñaki; Vera-Garcia, Francisco J

    2018-05-18

    Although the Star Excursion Balance test (SEBT) has shown a good intrasession reliability, the intersession reliability of this test has not been deeply studied. Furthermore, there is an evident high influence of the lower limbs in the performance of the SEBT, so even if it has been used to measure core stability, it is possibly not the most suitable measurement. The aims of this study were to (1) to assess the absolute and relative between-session reliability of the SEBT and 2 novel variations of this test to assess trunk postural control while sitting, ie, the Star Excursion Sitting Test (SEST) and the Star Excursion Timing Test (SETT); and (2) to analyze the relationships between these 3 test scores. Correlational and reliability test-retest study. Controlled laboratory environment. Twenty-seven physically active men (age: 24.54 ± 3.05 years). Relative and absolute reliability of the SEBT, SEST, and SETT were calculated through the intraclass correlation coefficient (ICC) and standard error of measurement (SEM), respectively. A Pearson correlation analysis was carried out between the variables of the 3 tests. Maximum normalized reach distances were assessed for different SEBT and SEST directions. In addition, composite indexes were calculated for SEBT, SEST, and SETT. The SEBT (dominant leg: ICC = 0.87 [0.73-0.94], SEM = 2.12 [1.66-2.93]; nondominant leg: ICC = 0.74 [0.50-0.87], SEM = 3.23 [2.54-4.45]), SEST (ICC = 0.85 [0.68-0.92], SEM = 1.27 [1.03-1.80]), and SETT (ICC = 0.61 [0.30-0.80], SEM = 2.31 [1.82-3.17]) composite indexes showed moderate-to-high 1-month reliability. A learning effect was detected for some SEBT and SEST directions and for SEST and SETT composite indexes. No significant correlations were found between SEBT and its 2 variations (r ≤ .366; P > .05). A significant correlation was found between the SEST and SETT composite indexes (r = .520; P > .01). SEBT, SEST, and SETT are reliable field protocols to measure postural control. However

  20. Reliability of anthropometric measurements in young male and female artistic gymnasts.

    Science.gov (United States)

    Siatras, Theophanis; Skaperda, Malamati; Mameletzi, Dimitra

    2010-12-01

    Body dimensions and body composition of children participating in artistic activities, such as gymnastics and many types of dancing, are important factors in performance improvement. The present study aimed to determine the reliability of a series of selected anthropometric measurements in young male and female gymnasts. Segment lengths, body breadths, circumferences, and skinfold thickness were measured in 20 young gymnasts by the same experienced examiner, using portable and easy-to-use instruments. All parameters were measured twice (test-retest) under the same conditions within a week's period. The high intra-class correlation coefficient (ICC) values ranging from 0.87 to 0.99, as well as the low coefficient of variation (CV) values (artistic gymnasts. Therefore, these measurements could contribute to further research in this field of investigation, helping to monitor young artistic gymnasts' growth status and identify specific characteristics for increased performance in this sport.

  1. Reliability of Measuring Lumbar Lordosis, Flexion and Extension Using Dual Inclinometer in Healthy Subjects and Patients with Non-Specific Chronic Low Back Pain

    Directory of Open Access Journals (Sweden)

    Samira Garmabi

    2012-07-01

    Full Text Available Objective: Accurate assessment of lumbar range of motion is of great value for both evaluating lumbar functions and monitoring treatment progress. Recent research indicates that there is no general consensus on the most valid and reliable method of measuring spinal range of motion. The purpose of this study was to determine the intra-rater reliability of lumbar flexion and extension measurements (within-day and between-days using the dual inclinometer technique.   Materials & Methods: Lumbar flexion and extension of 22 women (14 healthy and 8 with low back pain, were measured by the same examiner on three occasions. The first two measurements were taken with half an hour apart on the first occasion to assess the within-day reliability and the third measurement was taken one week later to assess the between-days reliability.  Results: Within-day lumbar lordosis, flexion and extension measurements using dual inclinometer technique were shown to be very reliable with high Intraclass Correlation Coefficients (ICC values (ICC were 98%, 77% and 69% for lordosis, flexion and extension measurements, respectively in healthy subjects and 94%, 95% and 69% for lordosis, flexion and extension measurements, respectively in patients group. Between-Days measurements also demonstrated high reliability with the high values of ICC (ICC were 96%, 70% and 67% for lordosis, flexion and extension measurements, in healthy subjects and 91%, 71% and 66% for lordosis, flexion and extension measurements, respectively in patients group. Conclusion: The results indicated that, the dual inclinometer technique appears to be a highly reliable method for measuring lumbar lordosis, flexion and extension and can be used as a reliable tool in the assessment of lumbar range of motion and monitoring therapeutic interventions.

  2. A study of operational and testing reliability in software reliability analysis

    International Nuclear Information System (INIS)

    Yang, B.; Xie, M.

    2000-01-01

    Software reliability is an important aspect of any complex equipment today. Software reliability is usually estimated based on reliability models such as nonhomogeneous Poisson process (NHPP) models. Software systems are improving in testing phase, while it normally does not change in operational phase. Depending on whether the reliability is to be predicted for testing phase or operation phase, different measure should be used. In this paper, two different reliability concepts, namely, the operational reliability and the testing reliability, are clarified and studied in detail. These concepts have been mixed up or even misused in some existing literature. Using different reliability concept will lead to different reliability values obtained and it will further lead to different reliability-based decisions made. The difference of the estimated reliabilities is studied and the effect on the optimal release time is investigated

  3. Measurement of critical mass for an assembly of bare uranium shells

    International Nuclear Information System (INIS)

    Myers, W.L.; Goulding, C.A.; Hollas, C.L.

    1997-01-01

    As part of the research into nuclear measurement techniques, a series of measurements was performed that have applications to criticality safety and nuclear material handling. The critical mass of a set of bare, enriched-uranium metal hemispherical shells, known as the Rocky Flats shells, was measured for an assembly having an inside radius of 2.347 cm. The critical mass value was extrapolated from a series of subcritical measurements using three different kinds of sources (AmBe, AmF, and 252 Cf) placed at the center of the shells. Two kinds of neutron detection configurations (a 1% efficiency and a 25% efficiency configuration) were used to make the measurements

  4. Test-Retest Reliability of Handgrip Strength as an Outcome Measure in Patients With Symptoms of Shoulder Impingement Syndrome.

    Science.gov (United States)

    Savva, Christos; Mougiaris, Paraskevas; Xadjimichael, Christoforos; Karagiannis, Christos; Efstathiou, Michalis

    The purpose of this study was to investigate the degree of test-retest reliability of grip strength measurement using a hand dynamometer in patients with shoulder impingement syndrome. A total of 19 patients (10 women and 9 men; mean ± standard deviation age, 33.2 ± 12.9 years; range 18-59 years) with shoulder impingement syndrome were measured using a hand dynamometer by the same data collector in 2 different testing sessions with a 7-day interval. During each session, patients were encouraged to exert 3 maximal isometric contractions on the affected hand and the mean value of the 3 efforts (measured in kilogram-force [Kgf]) was used for data analysis. The intraclass correlation coefficient (ICC 2,1 ) as well as the standard error of measurement (SEM) and Bland-Altman plot were used to estimate the degree of test-retest reliability and the measurement error, respectively. Grip strength data analysis revealed an ICC 2,1 score of 0.94, which, based on the Shrout classification, is considered as excellent test-retest reliability of grip strength measurement. The small values of SEMs reported in both sessions (SEM 1 , 2.55 Kgf; SEM 2 , 2.39 Kgf) and the small width of the 95% limits of agreement in the Bland-Altman plot (ranging from -7.39 Kgf to 7.03 Kgf) reflected the measurement precision and the narrow variation of the differences during the 2 testing sessions. Results from this study identified excellent test-retest reliability of grip strength measurement in shoulder impingement syndrome, indicating its potential use as an outcome measure in clinical practice. Copyright © 2018. Published by Elsevier Inc.

  5. Research of connection between mass audience and new media. Approaches to new model of mass communication measurement

    OpenAIRE

    Sibiriakova Olena Oleksandrivna

    2015-01-01

    In this research the author examines changes to approaches of observation of mass communication. As a result of systemization of key theoretical models of communication, the author comes to conclusion of evolution of ideas about the process of mass communication measurement from linear to multisided and multiple.

  6. A PRECISE MASS MEASUREMENT OF THE INTERMEDIATE-MASS BINARY PULSAR PSR J1802 - 2124

    International Nuclear Information System (INIS)

    Ferdman, R. D.; Cognard, I.; Desvignes, G.; Theureau, G.; Stairs, I. H.; Kramer, M.; McLaughlin, M. A.; Lorimer, D. R.; Nice, D. J.; Manchester, R. N.; Hobbs, G.; Lyne, A. G.; Faulkner, A.; Camilo, F.; Possenti, A.; Demorest, P. B.; Backer, D. C.

    2010-01-01

    PSR J1802 - 2124 is a 12.6 ms pulsar in a 16.8 hr binary orbit with a relatively massive white dwarf (WD) companion. These properties make it a member of the intermediate-mass class of binary pulsar (IMBP) systems. We have been timing this pulsar since its discovery in 2002. Concentrated observations at the Green Bank Telescope, augmented with data from the Parkes and Nancay observatories, have allowed us to determine the general relativistic Shapiro delay. This has yielded pulsar and WD mass measurements of 1.24 ± 0.11 M sun and 0.78 ± 0.04 M sun (68% confidence), respectively. The low mass of the pulsar, the high mass of the WD companion, the short orbital period, and the pulsar spin period may be explained by the system having gone through a common-envelope phase in its evolution. We argue that selection effects may contribute to the relatively small number of known IMBPs.

  7. Measuring neutrino masses with a future galaxy survey

    DEFF Research Database (Denmark)

    Hamann, Jan; Hannestad, Steen; Wong, Yvonne Y. Y.

    2012-01-01

    that the minimum mass sum of sum m_nu ~ 0.06 eV in the normal hierarchy can be detected at 1.5 sigma to 2.5 sigma significance, depending on the model complexity, using a combination of galaxy and cosmic shear power spectrum measurements in conjunction with CMB temperature and polarisation observations from Planck....... With better knowledge of the galaxy bias, the significance of the detection could potentially reach 5.4 sigma. Interestingly, neither Planck+shear nor Planck+galaxy alone can achieve this level of sensitivity; it is the combined effect of galaxy and cosmic shear power spectrum measurements that breaks......) in the parameter estimation is induced by fitting inaccurate models of the neutrino mass splittings to the mock data, nor does the goodness-of-fit of these models suffer any significant degradation relative to the true one (Delta chi_eff ^2

  8. Invariant measures of mass migration processes

    Czech Academy of Sciences Publication Activity Database

    Fajfrová, Lucie; Gobron, T.; Saada, E.

    2016-01-01

    Roč. 21, č. 1 (2016), s. 1-52, č. článku 60. ISSN 1083-6489 R&D Projects: GA ČR GAP201/12/2613; GA ČR(CZ) GA16-15238S Institutional support: RVO:67985556 Keywords : interacting particle systems * product invariant measures * zero range process * target process * mass migration process * condensation Subject RIV: BA - General Mathematics Impact factor: 0.904, year: 2016 http://library.utia.cas.cz/separaty/2016/SI/fajfrova-0464455.pdf

  9. Test-retest reliability and minimal detectable change of two simplified 3-point balance measures in patients with stroke.

    Science.gov (United States)

    Chen, Yi-Miau; Huang, Yi-Jing; Huang, Chien-Yu; Lin, Gong-Hong; Liaw, Lih-Jiun; Lee, Shih-Chieh; Hsieh, Ching-Lin

    2017-10-01

    The 3-point Berg Balance Scale (BBS-3P) and 3-point Postural Assessment Scale for Stroke Patients (PASS-3P) were simplified from the BBS and PASS to overcome the complex scoring systems. The BBS-3P and PASS-3P were more feasible in busy clinical practice and showed similarly sound validity and responsiveness to the original measures. However, the reliability of the BBS-3P and PASS-3P is unknown limiting their utility and the interpretability of scores. We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BBS-3P and PASS-3P in patients with stroke. Cross-sectional study. The rehabilitation departments of a medical center and a community hospital. A total of 51 chronic stroke patients (64.7% male). Both balance measures were administered twice 7 days apart. The test-retest reliability of both the BBS-3P and PASS-3P were examined by intraclass correlation coefficients (ICC). The MDC and its percentage over the total score (MDC%) of each measure was calculated for examining the random measurement errors. The ICC values of the BBS-3P and PASS-3P were 0.99 and 0.97, respectively. The MDC% (MDC) of the BBS-3P and PASS-3P were 9.1% (5.1 points) and 8.4% (3.0 points), respectively, indicating that both measures had small and acceptable random measurement errors. Our results showed that both the BBS-3P and the PASS-3P had good test-retest reliability, with small and acceptable random measurement error. These two simplified 3-level balance measures can provide reliable results over time. Our findings support the repeated administration of the BBS-3P and PASS-3P to monitor the balance of patients with stroke. The MDC values can help clinicians and researchers interpret the change scores more precisely.

  10. Indigenous instrumentation for mass spectrometry: Part II - development of plasma source mass spectrometers. PD-5-3

    International Nuclear Information System (INIS)

    Nataraju, V.

    2007-01-01

    The growing demands from analytical community, for a precise isotope ratio and ultra trace concentration measurements, has lead to significant improvement in mass spectrometer instrumentation development with respect to sensitivity, detection limits, precision and accuracy. Among the many analytical techniques available, plasma source mass spectrometers like Inductively Coupled Plasma Mass Spectrometry (ICPMS), multi collector (MC) ICPMS and Glow Discharge Mass Spectrometry (GDMS), have matured into reliable tools for the above applications. Where as ICPMS is by far the most successful method for aqueous solutions, GDMS is being applied for bulk and impurity analysis of conducting as well non-conducting solids. VPID, BARC has been developing mass spectrometers for different inorganic applications of DAE users. Over the years expertise has been developed in all the aspects of mass spectrometry instrumentation. Part 1 of this indigenous instrumentation on mass spectrometry gives details of magnetic sector instruments with either EI or TI source for isotopic ratio analysis. The present paper is a continuation of that on plasma source and quadrupole mass spectrometers. This paper covers i) ICP-QMS, ii) MC-ICPMS, iii) GDMS and iv) QMS

  11. Representativeness of regional and global mass-balance measurement networks (Invited)

    Science.gov (United States)

    Cogley, J. G.; Moholdt, G.; Gardner, A. S.

    2013-12-01

    We showed in a recent publication that regional estimates of glacier mass budgets, obtained by interpolation from in-situ measurements, were markedly more negative than corresponding estimates by satellite gravimetry (GRACE) and satellite altimetry (ICESat) during 2003-2009. Examining the ICESat data in more detail, we found that in-situ records tend to be located in areas where glaciers are thinning more rapidly than as observed in their regional surroundings. Because neither GRACE nor ICESat can provide information for times before 2002-2003, and may not operate without interruption in the future, we explore possible explanations of and remedies for the identified bias in the in-situ network. Sparse spatial sampling, coupled with previously undetected spatial variability of mass balance at scales between the 10-km in-situ scale and the 350-km gravimetric scale, appears to be the leading explanation. Satisfactory remedies are not obvious. Selecting glaciers for in-situ measurement that are more representative will yield only incremental improvements. There appears to be no alternative to mass-balance modelling as a versatile tool for estimation of regional mass balance. However the meteorological data for forcing the surface components of glacier models have coarser resolution than is desirable and are themselves uncertain, especially in the remote regions where much of the glacier ice is found. Measurements of frontal (dynamic) mass changes are still difficult, and modelling of these changes remains underdeveloped in spite of recent advances. Thus research on a broad scale is called for in order to meet the challenge of producing more accurate hindcasts and projections of glacier mass budgets with fine spatial and temporal resolution.

  12. High frequency body mass measurement, feedback, and health behaviors

    NARCIS (Netherlands)

    Kooreman, P.; Scherpenzeel, A.

    We analyze weight and fat percentage measurements of respondents in an online general population panel in the Netherlands, collected using wireless scales, with an average frequency of 1.6 measurements per week. First, we document the existence of a weekly cycle; body mass is lowest on Fridays and

  13. [Evaluation of mass spectrometry: MALDI-TOF MS for fast and reliable yeast identification].

    Science.gov (United States)

    Relloso, María S; Nievas, Jimena; Fares Taie, Santiago; Farquharson, Victoria; Mujica, María T; Romano, Vanesa; Zarate, Mariela S; Smayevsky, Jorgelina

    2015-01-01

    The matrix-assisted laser desorption/ionization time-of-flight mass spectrometry technique known as MALDI-TOF MS is a tool used for the identification of clinical pathogens by generating a protein spectrum that is unique for a given species. In this study we assessed the identification of clinical yeast isolates by MALDI-TOF MS in a university hospital from Argentina and compared two procedures for protein extraction: a rapid method and a procedure based on the manufacturer's recommendations. A short protein extraction procedure was applied in 100 isolates and the rate of correct identification at genus and species level was 98.0%. In addition, we analyzed 201 isolates, previously identified by conventional methods, using the methodology recommended by the manufacturer and there was 95.38% coincidence in the identification at species level. MALDI TOF MS showed to be a fast, simple and reliable tool for yeast identification. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Mechanical Q-factor measurements on a test mass with a structured surface

    Energy Technology Data Exchange (ETDEWEB)

    Nawrodt, R [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Zimmer, A [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Koettig, T [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Clausnitzer, T [Institut fuer Angewandte Physik, Friedrich-Schiller-Universitaet Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Bunkowski, A [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut) and Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover, Callinstr. 38, D-30167 Hannover (Germany); Kley, E B [Institut fuer Angewandte Physik, Friedrich-Schiller-Universitaet Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Schnabel, R [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut) and Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover, Callinstr. 38, D-30167 Hannover (Germany); Danzmann, K [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut) and Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover, Callinstr. 38, D-30167 Hannover (Germany); Nietzsche, S [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Vodel, W [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Tuennermann, A [Institut fuer Angewandte Physik, Friedrich-Schiller-Universitaet Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Seidel, P [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany)

    2007-07-15

    We present mechanical Q-factors (quality factors) of a crystalline quartz test mass with a nano-structured surface, measured in the temperature regime from 5 to 300 K. The nano-structure was a grating with a period of 2 {mu}m and a depth of about 0.1 {mu}m. Comparative measurements were performed on the plain substrate and on the structured test mass with different numbers of SiO{sub 2}/Ta{sub 2}O{sub 5} coating layers. The measurements at different stages of the test mass fabrication process show that the surface distortion induced by the nanostructure does not severely lower the mechanical Q-factor of the substrate. Damping due to a multi-layer coating stack was found to be orders of magnitude higher. The results provide vital information concerning the potential usage of low-thermal noise nano-structured test masses in future generations of high-precision laser interferometers and in current attempts to measure quantum effects of macroscopic mirror oscillators.

  15. Intercomparison of techniques for the non-invasive measurement of bone mass

    International Nuclear Information System (INIS)

    Cohn, S.H.

    1981-01-01

    A variety of methods are presently available for the non-invasive measurement of bone mass of both normal individuals and patients with metabolic disorders. Chief among these methods are radiographic techniques such as radiogrammetry, photon absorptiometry, computer tomography, Compton scattering and neutron activation analysis. In this review, the salient features of the bone measurement techniques are discussed along with their accuracy and precision. The advantages and disadvantages of the various techniques for measuring bone mass are summarized. Where possible, intercomparisons are made of the various techniques

  16. Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the Spinal Deformity Study Group's AIS Radiographic Measurement Manual.

    Science.gov (United States)

    Dang, Natasha Radhika; Moreau, Marc J; Hill, Douglas L; Mahood, James K; Raso, James

    2005-05-01

    Retrospective cross-sectional assessment of the reproducibility and reliability of radiographic parameters. To measure the intra-examiner and interexaminer reproducibility and reliability of salient radiographic features. The management and treatment of adolescent idiopathic scoliosis (AIS) depends on accurate and reproducible radiographic measurements of the deformity. Ten sets of radiographs were randomly selected from a sample of patients with AIS, with initial curves between 20 degrees and 45 degrees. Fourteen measures of the deformity were measured from posteroanterior and lateral radiographs by 2 examiners, and were repeated 5 times at intervals of 3-5 days. Intra-examiner and interexaminer differences were examined. The parameters include measures of curve size, spinal imbalance, sagittal kyphosis and alignment, maximum apical vertebral rotation, T1 tilt, spondylolysis/spondylolisthesis, and skeletal age. Intra-examiner reproducibility was generally excellent for parameters measured from the posteroanterior radiographs but only fair to good for parameters from the lateral radiographs, in which some landmarks were not clearly visible. Of the 13 parameters observed, 7 had excellent interobserver reliability. The measurements from the lateral radiograph were less reproducible and reliable and, thus, may not add value to the assessment of AIS. Taking additional measures encourages a systematic and comprehensive assessment of spinal radiographs.

  17. Test-Retest Reliability of Self-Reported Sexual Health Measures among US Hispanic Adolescents

    Science.gov (United States)

    Jerman, Petra; Berglas, Nancy F.; Rohrbach, Louise A.; Constantine, Norman A.

    2016-01-01

    Objective: Although Hispanic adolescents in the USA are often the focus of sexual health interventions, their response to survey measures has rarely been assessed within evaluation studies. This study documents the test-retest reliability of a wide range of self-reported sexual health values, attitudes, knowledge and behaviours among Hispanic…

  18. Quantifying frontal plane knee motion during single limb squats: reliability and validity of 2-dimensional measures.

    Science.gov (United States)

    Gwynne, Craig R; Curran, Sarah A

    2014-12-01

    Clinical assessment of lower limb kinematics during dynamic tasks may identify individuals who demonstrate abnormal movement patterns that may lead to etiology of exacerbation of knee conditions such as patellofemoral joint (PFJt) pain. The purpose of this study was to determine the reliability, validity and associated measurement error of a clinically appropriate two-dimensional (2-D) procedure of quantifying frontal plane knee alignment during single limb squats. Nine female and nine male recreationally active subjects with no history of PFJt pain had frontal plane limb alignment assessed using three-dimensional (3-D) motion analysis and digital video cameras (2-D analysis) while performing single limb squats. The association between 2-D and 3-D measures was quantified using Pearson's product correlation coefficients. Intraclass correlation coefficients (ICCs) were determined for within- and between-session reliability of 2-D data and standard error of measurement (SEM) was used to establish measurement error. Frontal plane limb alignment assessed with 2-D analysis demonstrated good correlation compared with 3-D methods (r = 0.64 to 0.78, p < 0.001). Within-session (0.86) and between-session ICCs (0.74) demonstrated good reliability for 2-D measures and SEM scores ranged from 2° to 4°. 2-D measures have good consistency and may provide a valid measure of lower limb alignment when compared to existing 3-D methods. Assessment of lower limb kinematics using 2-D methods may be an accurate and clinically useful alternative to 3-D motion analysis when identifying individuals who demonstrate abnormal movement patterns associated with PFJt pain. 2b.

  19. Applicability of hydraulic dynamometer for measuring load mass on forwarders

    Directory of Open Access Journals (Sweden)

    Pandur Zdravko

    2015-01-01

    Full Text Available In the last few years, with the start of wood biomass production from wood residues, the need for determining the quantity of extracted wood residuals on a landing site has appeared. The beginning of intensive usage of wood residues for wood biomass starts in lowland forest where all wood residues are extracted with forwarders. There are several ways to determine load mass on a forwarder, first and probably most accurate is the use of load cells which are installed between forwarder undercarriage and loading space. In Croatia, as far as it is known, there is no forwarder with such equipment, although manufacturers offer the installation of such equipment when buying a new forwarder. The second option is using a portable measuring platform (axle scale which was already used for research of axle loads of trucks and forwarders. The data obtained with the measuring platform are very accurate, while its deficiency is relatively great mass, large dimensions and high price. The third option is determining mass by using hydraulic dynamometer which is installed on crane between the rotator and the telescopic boom. The production and installation of such a system is very simple, and with the price it can easily compete with previously described measuring systems. The main deficiency of this system is its unsatisfying accuracy. The results of assortment mass measuring with hydraulic dynamometer installed on a hydraulic crane and discussion on factors influencing obtained results will be presented in this paper.

  20. Mass transfer effects in hygroscopic measurements of aerosol particles

    Directory of Open Access Journals (Sweden)

    M. N. Chan

    2005-01-01

    Full Text Available The tandem differential mobility analyzer (TDMA has been widely utilized to measure the hygroscopicity of laboratory-generated and atmospheric submicrometer particles. An important concern in investigating the hygroscopicity of the particles is if the particles have attained equilibrium state in the measurements. We present a literature survey to investigate the mass transfer effects in hygroscopicity measurements. In most TDMA studies, a residence time in the order of seconds is used for humidification (or dehumidification. NaCl and (NH42SO4 particles are usually used to verify the equilibrium measurements during this residence time, which is presumed to be sufficient for other particles. There have been observations that not all types of submicrometer particles, including atmospheric particles, attain their equilibrium sizes within this time scale. We recommend that experimentation with different residence times be conducted and that the residence time should be explicitly stated in future TDMA measurements. Mass transfer effects may also exist in the measurements of other properties related to the water uptake of atmospheric particles such as relative humidity dependent light scattering coefficients and cloud condensation nuclei activity.