WorldWideScience

Sample records for reliable laboratory exercises

  1. Soil sampling intercomparison exercise by selected laboratories of the ALMERA Network

    International Nuclear Information System (INIS)

    2009-01-01

    The IAEA's Seibersdorf Laboratories in Austria have the programmatic responsibility to provide assistance to Member State laboratories in maintaining and improving the reliability of analytical measurement results, both in radionuclide and trace element determinations. This is accomplished through the provision of reference materials of terrestrial origin, validated analytical procedures, training in the implementation of internal quality control, and through the evaluation of measurement performance by the organization of worldwide and regional interlaboratory comparison exercises. The IAEA is mandated to support global radionuclide measurement systems related to accidental or intentional releases of radioactivity in the environment. To fulfil this obligation and ensure a reliable, worldwide, rapid and consistent response, the IAEA coordinates an international network of analytical laboratories for the measurement of environmental radioactivity (ALMERA). The network was established by the IAEA in 1995 and makes available to Member States a world-wide network of analytical laboratories capable of providing reliable and timely analysis of environmental samples in the event of an accidental or intentional release of radioactivity. A primary requirement for the ALMERA members is participation in the IAEA interlaboratory comparison exercises, which are specifically organized for ALMERA on a regular basis. These exercises are designed to monitor and demonstrate the performance and analytical capabilities of the network members, and to identify gaps and problem areas where further development is needed. In this framework, the IAEA organized a soil sampling intercomparison exercise (IAEA/SIE/01) for selected laboratories of the ALMERA network. The main objective of this exercise was to compare soil sampling procedures used by different participating laboratories. The performance evaluation results of the interlaboratory comparison exercises performed in the framework of

  2. Procedures of Exercise Physiology Laboratories

    Science.gov (United States)

    Bishop, Phillip A.; Fortney, Suzanne; Greenisen, Michael; Siconolfi, Steven F.; Bamman, Marcas M.; Moore, Alan D., Jr.; Squires, William

    1998-01-01

    This manual describes the laboratory methods used to collect flight crew physiological performance data at the Johnson Space Center. The Exercise Countermeasures Project Laboratory is a standard physiology laboratory; only the application to the study of human physiological adaptations to spaceflight is unique. In the absence of any other recently published laboratory manual, this manual should be a useful document staffs and students of other laboratories.

  3. Simulation of General Physics laboratory exercise

    International Nuclear Information System (INIS)

    Aceituno, P; Hernández-Cabrera, A; Hernández-Aceituno, J

    2015-01-01

    Laboratory exercises are an important part of general Physics teaching, both during the last years of high school and the first year of college education. Due to the need to acquire enough laboratory equipment for all the students, and the widespread access to computers rooms in teaching, we propose the development of computer simulated laboratory exercises. A representative exercise in general Physics is the calculation of the gravity acceleration value, through the free fall motion of a metal ball. Using a model of the real exercise, we have developed an interactive system which allows students to alter the starting height of the ball to obtain different fall times. The simulation was programmed in ActionScript 3, so that it can be freely executed in any operative system; to ensure the accuracy of the calculations, all the input parameters of the simulations were modelled using digital measurement units, and to allow a statistical management of the resulting data, measurement errors are simulated through limited randomization

  4. Human factors reliability Benchmark exercise

    International Nuclear Information System (INIS)

    Poucet, A.

    1989-06-01

    The Joint Research Centre of the European Commission has organized a Human Factors Reliability Benchmark Exercise (HF-RBE) with the aim of assessing the state of the art in human reliability modelling and assessment. Fifteen teams from eleven countries, representing industry, utilities, licensing organisations and research institutes, participated in the HF-RBE. The HF-RBE was organized around two study cases: (1) analysis of routine functional Test and Maintenance (T and M) procedures: with the aim of assessing the probability of test induced failures, the probability of failures to remain unrevealed and the potential to initiate transients because of errors performed in the test; (2) analysis of human actions during an operational transient: with the aim of assessing the probability that the operators will correctly diagnose the malfunctions and take proper corrective action. This report contains the final summary reports produced by the participants in the exercise

  5. Results of the event sequence reliability benchmark exercise

    International Nuclear Information System (INIS)

    Silvestri, E.

    1990-01-01

    The Event Sequence Reliability Benchmark Exercise is the fourth of a series of benchmark exercises on reliability and risk assessment, with specific reference to nuclear power plant applications, and is the logical continuation of the previous benchmark exercises on System Analysis Common Cause Failure and Human Factors. The reference plant is the Nuclear Power Plant at Grohnde Federal Republic of Germany a 1300 MW PWR plant of KWU design. The specific objective of the Exercise is to model, to quantify and to analyze such event sequences initiated by the occurrence of a loss of offsite power that involve the steam generator feed. The general aim is to develop a segment of a risk assessment, which ought to include all the specific aspects and models of quantification, such as common canal failure, Human Factors and System Analysis, developed in the previous reliability benchmark exercises, with the addition of the specific topics of dependences between homologous components belonging to different systems featuring in a given event sequence and of uncertainty quantification, to end up with an overall assessment of: - the state of the art in risk assessment and the relative influences of quantification problems in a general risk assessment framework. The Exercise has been carried out in two phases, both requiring modelling and quantification, with the second phase adopting more restrictive rules and fixing certain common data, as emerged necessary from the first phase. Fourteen teams have participated in the Exercise mostly from EEC countries, with one from Sweden and one from the USA. (author)

  6. ES-RBE Event sequence reliability Benchmark exercise

    International Nuclear Information System (INIS)

    Poucet, A.E.J.

    1991-01-01

    The event Sequence Reliability Benchmark Exercise (ES-RBE) can be considered as a logical extension of the other three Reliability Benchmark Exercices : the RBE on Systems Analysis, the RBE on Common Cause Failures and the RBE on Human Factors. The latter, constituting Activity No. 1, was concluded by the end of 1987. The ES-RBE covered the techniques that are currently used for analysing and quantifying sequences of events starting from an initiating event to various plant damage states, including analysis of various system failures and/or successes, human intervention failure and/or success and dependencies between systems. By this way, one of the scopes of the ES-RBE was to integrate the experiences gained in the previous exercises

  7. Laboratory exercises to teach clinically relevant chemistry of antibiotics.

    Science.gov (United States)

    El Sayed, Khalid A; Chelette, Candace T

    2014-03-12

    To design, implement, and evaluate student performance on clinically relevant chemical and spectral laboratory exercises on antibiotics. In the first of 2 exercises, second-year pharmacy students enrolled in an integrated laboratory sequence course studied the aqueous stability of ß-lactam antibiotics using a spectral visual approach. In a second exercise, students studied the tendency of tetracycline, rifamycins, and fluoroquinolones to form insoluble chelate complexes (turbidity) with polyvalent metals. On a survey to assess achievement of class learning objectives, students agreed the laboratory activities helped them better retain important information concerning antibiotic stability and interactions. A significant improvement was observed in performance on examination questions related to the laboratory topics for 2012 and 2013 students compared to 2011 students who did not complete the laboratory. A 1-year follow-up examination question administered in a separate course showed >75% of the students were able to identify rifamycins-food interactions compared with laboratory exercises. The use of spectral visual approaches allowed students to investigate antibiotic stability and interactions, thus reinforcing the clinical relevance of medicinal chemistry. Students' performance on questions at the 1-year follow-up suggested increased retention of the concepts learned as a result of completing the exercises.

  8. Inter-laboratory exercise on steroid estrogens in aqueous samples

    DEFF Research Database (Denmark)

    Heath, E.; Kosjek, T.; Andersen, Henrik Rasmus

    2010-01-01

    to the analytical techniques applied, the accuracy and reproducibility of the analytical methods and the nature of the sample matrices. Overall, the results obtained in this inter-laboratory exercise reveal a high level of competence among the participating laboratories for the detection of steroid estrogens......An inter-laboratory comparison exercise was organized among European laboratories, under the aegis of EU COST Action 636: "Xenobiotics in Urban Water Cycle" The objective was to evaluate the performance of testing laboratories determining "Endocrine Disrupting Compounds" (EDC) in various aqueous...

  9. Systems reliability Benchmark exercise part 1-Description and results

    International Nuclear Information System (INIS)

    Amendola, A.

    1986-01-01

    The report describes aims, rules and results of the Systems Reliability Benchmark Exercise, which has been performed in order to assess methods and procedures for reliability analysis of complex systems and involved a large number of European organizations active in NPP safety evaluation. The exercise included both qualitative and quantitative methods and was structured in such a way that separation of the effects of uncertainties in modelling and in data on the overall spread was made possible. Part I describes the way in which RBE has been performed, its main results and conclusions

  10. Emergency response exercise of laboratories equipped with gammaspectrometry

    International Nuclear Information System (INIS)

    Mala, H.; Jezkova, T.; Rulik, P.; Beckova, V.

    2014-01-01

    Seven laboratories equipped with semiconductor gamma spectrometry (HPGe detectors) are currently included in the Radiation Monitoring Network (RMN) in the Czech Republic. These laboratories have more than 30 spectrometric chains and approximately 20 'experts' and 70 'users' who would guarantee measurements during the radiological emergency (RE). The emergency exercise was carried out in 5 of them in 2014 (in 4 of them also in 2013). The aim was to test repeatedly their capacity in existing technical facilities and with current staff in the event of a RE and identify problems (bottlenecks) in the whole process from receipt of samples to entering the results into the central database of RMN. Duration of the exercise was 12 hours, due to the shortage of staff; work in one 12-hour shift is presumed during a RE, which the laboratories should be able to provide for 14 days. These exercise samples covered a wide range of commodities that would probably come to the laboratories during the RE (aerosol filters, sorbents for sorption of gaseous forms of iodine, fallout, surface and drinking waters, food chain components and soils). Some of the samples were previously spiked with 85 Sr, 88 Y and 40 K (in the exercise these nuclides represented actual contamination that would occur in RE); liquid samples were spiked with 85 Sr and 88 Y and bulk materials with 40 K.During the exercise almost 800 samples were analysed; in addition, the automatic gamma counter (GA) in Prague laboratory measured other 90 samples automatically during the night (samples were prepared during the day-shift). On the basis of the results the total measuring capacity of the laboratories of RMN CR was estimated at about 1300 samples per day. (authors)

  11. Evaluation of the Virtual Physiology of Exercise Laboratory Program

    Science.gov (United States)

    Dobson, John L.

    2009-01-01

    The Virtual Physiology of Exercise Laboratory (VPEL) program was created to simulate the test design, data collection, and analysis phases of selected exercise physiology laboratories. The VPEL program consists of four modules: (1) cardiovascular, (2) maximal O[subscript 2] consumption [Vo[subscript 2max], (3) lactate and ventilatory thresholds,…

  12. GHSI emergency radionuclide bioassay laboratory network - summary of the second exercise

    International Nuclear Information System (INIS)

    Li, Chunsheng; Ko, Raymond; Quayle, Debora; Sadi, Baki; Bartizel, Christine; Battisti, Paolo; Boettger, Axel; Bouvier, Celine; Paquet, Francois; CapoteCuellar, Antonio; Carr, Zhanat; Hammond, Derek; Hartmann, Martina; Heikkinen, Tarja; Jones, Robert L.; Kim, Eunjoo; Koga, Roberto; Kukhta, Boris; Mitchell, Lorna; Morhard, Ryan; Rulik, Petr; Sergei, Aleksanin; Sierra, Inmaculada; Oliveira Sousa, Wandersonde; Szabo, Gyula

    2017-01-01

    The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency as a means of enhancing response capability, health outcomes and community resilience. GHSI partners conducted an exercise in collaboration with the WHO Radiation Emergency Medical Preparedness and Assistance Network and the IAEA Response and Assistance Network, to test the participating laboratories (18) for their capabilities in in vitro assay of biological samples, using a urine sample spiked with multiple high-risk radionuclides ( 90 Sr, 106 Ru, 137 Cs, and 239 Pu). Laboratories were required to submit their reports within 72 h following receipt of the sample, using a pre-formatted template, on the procedures, methods and techniques used to identify and quantify the radionuclides in the sample, as well as the bioassay results with a 95% confidence interval. All of the participating laboratories identified and measured all or some of the radionuclides in the sample. However, gaps were identified in both the procedures used to assay multiple radionuclides in one sample, as well as in the methods or techniques used to assay specific radionuclides in urine. Two-third of the participating laboratories had difficulties in determining all the radionuclides in the sample. Results from this exercise indicate that challenges remain with respect to ensuring that results are delivered in a timely, consistent and reliable manner to support medical interventions. Laboratories within the networks are encouraged to work together to develop and maintain collective capabilities and capacity for emergency bioassay, which is an important component of radiation emergency response. (authors)

  13. A laboratory exercise on systematic effects in gamma ray spectrometry

    International Nuclear Information System (INIS)

    Henrik Ramebaeck

    2015-01-01

    A laboratory exercise for calculation of true coincidence summing correction factors as well as calculating the effect of deviations between sample and standard source (filling height) was developed. This laboratory exercise was held in a masters course in nuclear chemistry the first time during fall 2013. The aim of the exercise was to high-light the importance of correcting for biases due to different systematic effects in gamma spectrometric measurements. (author)

  14. Emergency response exercise of laboratories equipped with gamma spectrometry

    International Nuclear Information System (INIS)

    Mala, H.; Jezkova, T.; Rulik, P.; Beckova, V. et al.

    2014-01-01

    Seven laboratories equipped with semiconductor gamma spectrometry (HPGe detectors) are currently included in the Radiation Monitoring Network (RMN) in the Czech Republic. These laboratories have more than 30 spectrometric chains and approximately 20 'experts' and 70 'users' who would guarantee measurements during the radiological emergency (RE). The emergency exercise was carried out in 5 of them in 2014 (in 4 of them also in 2013). The aim was to test repeatedly their capacity in existing technical facilities and with current staff in the event of a RE and identify problems (bottlenecks) in the whole process from receipt of samples to entering the results into the central database of RMN. Duration of the exercise was 12 hours, due to the shortage of staff; work in one 12-hour shift is presumed during a RE, which the laboratories should be able to provide for 14 days. These exercise samples covered a wide range of commodities that would probably come to the laboratories during the RE (aerosol filters, sorbents for sorption of gaseous forms of iodine, fallout, surface and drinking waters, food chain components and soils). Some of the samples were previously spiked with 85 Sr, 88 Y and 40 K (in the exercise these nuclides represented actual contamination that would occur in RE); liquid samples were spiked with 85 Sr and 88 Y and bulk materials with 40 K.During the exercise almost 800 samples were analysed; in addition, the automatic gamma counter (GA) in Prague laboratory measured other 90 samples automatically during the night (samples were prepared during the day-shift). On the basis of the results the total measuring capacity of the laboratories of RMN CR was estimated at about 1300 samples per day. (authors)

  15. Laboratory Exercise to Evaluate Hay Preservatives.

    Science.gov (United States)

    McGraw, R. L.; And Others

    1990-01-01

    Presented is a laboratory exercise designed to demonstrate the effects of moisture on hay preservation products in a manner that does not require large amounts of equipment or instructor time. Materials, procedures, and probable results are discussed. (CW)

  16. Systemic Exercise-Induced Hypoalgesia Following Isometric Exercise Reduces Conditioned Pain Modulation

    DEFF Research Database (Denmark)

    Alsouhibani, Ali; Vaegter, Henrik Bjarke; Hoeger Bement, Marie

    2018-01-01

    Objective: Physically active individuals show greater conditioned pain modulation (CPM) compared with less active individuals. Understanding the effects of acute exercise on CPM may allow for a more targeted use of exercise in the management of pain. This study investigated the effects of acute...... isometric exercise on CPM. In addition, the between-session and within-session reliability of CPM was investigated. Design: Experimental, randomized crossover study. Setting: Laboratory at Marquette University. Subjects: Thirty healthy adults (19.3±1.5 years, 15 males). Methods: Subjects underwent CPM....... Results: PPTs increased during ice water immersion (i.e., CPM), and quadriceps PPT increased after exercise (P CPM decreased similarly following exercise and quiet rest (P > 0.05). CPM within-session reliability was fair to good (intraclass correlation coefficient [ICC] = 0...

  17. Using Mobile Devices for Motor-Learning Laboratory Exercises

    Science.gov (United States)

    Hill, Kory

    2014-01-01

    When teaching motor-learning concepts, laboratory experiments can be valuable tools for promoting learning. In certain circumstances, traditional laboratory exercises are often impractical due to facilities, time, or cost. Inexpensive or free applications (apps) that run on mobile devices can serve as useful alternatives. This article details…

  18. Emergency response exercise of laboratories equipped with gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mala, Helena; Rulik, Petr; Jezkova, Tereza; Beckova, Vera [National Radiation Protection Institute (SURO), 140 00 Praha 28 (Czech Republic)

    2014-07-01

    At present 7 laboratories equipped with semiconductor gamma spectrometry (HPGe detectors) are included in the Radiation Monitoring Network (RMN) in the Czech Republic. These laboratories have 31 spectrometric chains and approximately 20 'experts' and 70 'users' who would guarantee measurements during a radiological emergency (RE). The stress exercise (a load test) was carried out in 4 of them. The aim was to test their measuring capacity in existing technical facilities and staff in the event of a RE and identify problems (bottlenecks) in the whole process from receipt of samples to entering the results into the central database of RMN. Duration of the exercise was 8 to 14 hours. Due to lack of staff, work in one 12-hour shift during a RE is presumed, which the laboratories should be able to provide for 14 days. Exercise samples covered a wide range of commodities that would probably come to the laboratories during RE (aerosol filters, adsorbed gaseous forms of iodine, fallout, surface and drinking waters, food chain components and soils). Some of the samples were previously spiked with {sup 85}Sr, {sup 88}Y and {sup 40}K (these nuclides represented actual nuclides that would occur in RE); soil samples contained higher values of {sup 137}Cs activity originating from the Chernobyl accident. Almost 40 employees took part in the exercise and measurements were carried out at 18 spectrometric chains. An automatic gamma counter which allows automatic operation of two HPGe detectors including the analysis of the spectra with a storage for up to 180 sample containers was operating in one of the laboratories involved in the exercise. The procedures in individual laboratories varied slightly depending on the staff and laboratory space available. During the exercise about 700 samples were evaluated; in addition, gamma-automat measured other 80 samples in the 'night shift'. 700 samples, this means 40 samples per a spectrometric chain or, from

  19. Human factors reliability benchmark exercise, report of the SRD participation

    International Nuclear Information System (INIS)

    Waters, Trevor

    1988-01-01

    Within the scope of the Human Factors Reliability Benchmark Exercise, organised by the Joint Research Centre, Ispra, Italy, the Safety and Reliability Directorate (SRD) team has performed analysis of human factors in two different activities - a routine test and a non-routine operational transient. For both activities, an 'FMEA-like' task, potential errors, and the factors which affect performance. For analysis of the non-routine activity, which involved a significant amount of cognitive processing, such as diagnosis and decision making, a new approach for qualitative analysis has been developed. Modelling has been performed using both event trees and fault trees and examples are provided. Human error probabilities were estimated using the methods Absolute Probability Judgement (APJ), Human Cognitive Reliability Method (HCR), Human Error and Assessment and Reduction Technique (HEART), Success-Likelihood Index Method (SLIM), Technica Empiriza Stima Eurori Operatori (TESEO), and Technique for Human Error Rate Prediction (THERP). A discussion is provided of the lessons learnt in the course of the exercise and unresolved difficulties in the assessment of human reliability. (author)

  20. Reliability of Strength Testing using the Advanced Resistive Exercise Device and Free Weights

    Science.gov (United States)

    English, Kirk L.; Loehr, James A.; Laughlin, Mitzi A.; Lee, Stuart M. C.; Hagan, R. Donald

    2008-01-01

    The Advanced Resistive Exercise Device (ARED) was developed for use on the International Space Station as a countermeasure against muscle atrophy and decreased strength. This investigation examined the reliability of one-repetition maximum (1RM) strength testing using ARED and traditional free weight (FW) exercise. Methods: Six males (180.8 +/- 4.3 cm, 83.6 +/- 6.4 kg, 36 +/- 8 y, mean +/- SD) who had not engaged in resistive exercise for at least six months volunteered to participate in this project. Subjects completed four 1RM testing sessions each for FW and ARED (eight total sessions) using a balanced, randomized, crossover design. All testing using one device was completed before progressing to the other. During each session, 1RM was measured for the squat, heel raise, and deadlift exercises. Generalizability (G) and intraclass correlation coefficients (ICC) were calculated for each exercise on each device and were used to predict the number of sessions needed to obtain a reliable 1RM measurement (G . 0.90). Interclass reliability coefficients and Pearson's correlation coefficients (R) also were calculated for the highest 1RM value (1RM9sub peak)) obtained for each exercise on each device to quantify 1RM relationships between devices.

  1. Systems reliability Benchmark exercise part 2-Contributions by the participants

    International Nuclear Information System (INIS)

    Amendola, A.

    1986-01-01

    The report describes aims, rules and results of the Systems Reliability Benchmark Exercise, which has been performed in order to assess methods and procedures for reliability analysis of complex systems and involved a large number of European organizations active in NPP safety evaluation. The exercise included both qualitative and quantitative methods and was structured in such a way that separation of the effects of uncertainties in modelling and in data on the overall spread was made possible. This second part of the report is devoted to the documentation of the single contributions by the participant teams (Swedish, GRS, ENEA, NIRA and ENEL, EWE, EdF, Risoe, KWU/IA, ECN, KEMA/KUL, and Framatome contributions)

  2. Human factors reliability benchmark exercise

    International Nuclear Information System (INIS)

    Poucet, A.

    1989-08-01

    The Joint Research Centre of the European Commission has organised a Human Factors Reliability Benchmark Exercise (HF-RBE) with the aim of assessing the state of the art in human reliability modelling and assessment. Fifteen teams from eleven countries, representing industry, utilities, licensing organisations and research institutes, participated in the HF-RBE. The HF-RBE was organised around two study cases: (1) analysis of routine functional Test and Maintenance (TPM) procedures: with the aim of assessing the probability of test induced failures, the probability of failures to remain unrevealed and the potential to initiate transients because of errors performed in the test; (2) analysis of human actions during an operational transient: with the aim of assessing the probability that the operators will correctly diagnose the malfunctions and take proper corrective action. This report summarises the contributions received from the participants and analyses these contributions on a comparative basis. The aim of this analysis was to compare the procedures, modelling techniques and quantification methods used, to obtain insight in the causes and magnitude of the variability observed in the results, to try to identify preferred human reliability assessment approaches and to get an understanding of the current state of the art in the field identifying the limitations that are still inherent to the different approaches

  3. Validity and reliability of grade scoring in the diagnosis of exercise-induced laryngeal obstruction

    DEFF Research Database (Denmark)

    Walsted, Emil Schwarz; Hull, James H; Hvedstrup, Jeppe

    2017-01-01

    The current gold-standard method for diagnosing exercise-induced laryngeal obstruction (EILO) is continuous laryngoscopy during exercise (CLE), with severity classified by a visual grade scoring system. We evaluated the precision of this approach, by evaluating test-retest reliability of CLE...... grade scoring system does not appear to be a robust means for reliably classifying severity of EILO....

  4. Reliability on intra-laboratory and inter-laboratory data of hair mineral analysis comparing with blood analysis.

    Science.gov (United States)

    Namkoong, Sun; Hong, Seung Phil; Kim, Myung Hwa; Park, Byung Cheol

    2013-02-01

    Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.

  5. Inter-laboratory exercise on steroid estrogens in aqueous samples

    International Nuclear Information System (INIS)

    Heath, E.; Kosjek, T.; Andersen, H.R.; Holten Luetzhoft, H.-C.; Adolfson Erici, M.; Coquery, M.; Duering, R.-A.; Gans, O.; Guignard, C.; Karlsson, P.; Manciot, F.; Moldovan, Z.; Patureau, D.; Cruceru, L.; Sacher, F.; Ledin, A.

    2010-01-01

    An inter-laboratory comparison exercise was organized among European laboratories, under the aegis of EU COST Action 636: 'Xenobiotics in Urban Water Cycle'. The objective was to evaluate the performance of testing laboratories determining 'Endocrine Disrupting Compounds' (EDC) in various aqueous matrices. As the main task three steroid estrogens: 17α-ethinylestradiol, 17β-estradiol and estrone were determined in four spiked aqueous matrices: tap water, river water and wastewater treatment plant influent and effluent using GC-MS and LC-MS/MS. Results were compared and discussed according to the analytical techniques applied, the accuracy and reproducibility of the analytical methods and the nature of the sample matrices. Overall, the results obtained in this inter-laboratory exercise reveal a high level of competence among the participating laboratories for the detection of steroid estrogens in water samples indicating that GC-MS as well as LC-MS/MS can equally be employed for the analysis of natural and synthetic hormones. - Herein are presented the results of the first international inter-laboratory study on determination of selected steroid hormones in environmental aqueous samples.

  6. Reliability and Validity of the Self-Efficacy for Exercise in Epilepsy and the Outcome Expectations for Exercise in Epilepsy Scales.

    Science.gov (United States)

    Dustin, Irene; Resnick, Barbara; Galik, Elizabeth; Klinedinst, N Jennifer; Michael, Kathleen; Wiggs, Edythe

    2017-04-01

    The purpose of this study was to test the psychometric properties of the revised Self-Efficacy for Exercise With Epilepsy (SEE-E) and Outcome Expectations for Exercise with Epilepsy (OEE-E) when used with people with epilepsy. The SEE-E and OEE-E were given in face-to-face interviews to 26 persons with epilepsy in an epilepsy clinic. There was some evidence of validity based on Rasch analysis INFIT and OUTFIT statistics. There was some evidence of reliability for the SEE-E and OEE-E based on person and item separation reliability indexes. These measures can be used to identify persons with epilepsy who have low self-efficacy and outcome expectations for exercise and guide design of interventions to strengthen these expectations and thereby improve exercise behavior.

  7. Results of the Interlaboratory Exercise CSN/CIEMAT-100 Among Environmental Radioactivity Laboratories (Soil)

    International Nuclear Information System (INIS)

    Romero Gonzalez, M. L.

    2002-01-01

    The document describes the outcome of the CSN/CIEMAT-00 interlaboratory test comparison among environmental radioactivity laboratories. the exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC Harmonized Protocol for the proficiency testing of analytical laboratories. the test sample was a soil containing environmental levels of K-40, Ra-226, Ac-228, Sr-90, Cs-137, Cs-134, Pu (239-240) y Am-241. the Universidad Autonoma de Barcelona prepared the material and reported adequate statistical studies of homogeneity. The results of the exercise were computed for 30 participating laboratories, and their analytical performance was assessed using the u-score approach. A raised percentage of satisfactory laboratory performance has been obtained for all the analysis, being the best performance in gamma measurements. The exercise has drawn that several laboratories have difficulties in the evaluation of combined uncertainty, mainly in analysis involving radiochemical steps. The study has shown an homogeneous inter-laboratory behaviour, and the improvement achieved through subsequent exercises in the quality of the data they are producing. (Author) 10 refs

  8. The Miracle Fruit: An Undergraduate Laboratory Exercise in Taste Sensation and Perception.

    Science.gov (United States)

    Lipatova, Olga; Campolattaro, Matthew M

    2016-01-01

    "Miracle Fruit" is a taste-altering berry that causes sour foods to be perceived as sweet. The present paper describes a laboratory exercise that uses Miracle Fruit to educate students about the sensation and perception of taste. This laboratory exercise reinforces course material pertaining to the function of sweet taste receptors covered in a Sensation and Perception course at Christopher Newport University. Here we provide a step-by-step explanation of the methodology, and an example of data collected and analyzed by one group of students who participated in this laboratory exercise. The origins of the Miracle Fruit, the structure and the physiological function of miraculin (the glycoprotein responsible for the taste-modifying effect found in the pulp of the Miracle Fruit) were discussed before the laboratory exercise. Students then sampled foods known to target different types of tastes (i.e., sweet, sour, bitter and salty) and rated their perception of taste intensity for each food item. Next, students each consumed Miracle Fruit berries, then resampled each original food item and again recorded their perception of taste intensity ratings for these foods. The data confirmed that the sour food items were perceived sweeter after the Miracle Fruit was consumed. The students also completed a written assignment to assess what they learned about the origins, structure, and physiological function of Miracle Fruit. This hands-on laboratory exercise received positive feedback from students. The exercise can be used by other neuroscience educators to teach concepts related to the sensory system of taste.

  9. Blended learning within an undergraduate exercise physiology laboratory.

    Science.gov (United States)

    Elmer, Steven J; Carter, Kathryn R; Armga, Austin J; Carter, Jason R

    2016-03-01

    In physiological education, blended course formats (integration of face-to-face and online instruction) can facilitate increased student learning, performance, and satisfaction in classroom settings. There is limited evidence on the effectiveness of using blending course formats in laboratory settings. We evaluated the impact of blended learning on student performance and perceptions in an undergraduate exercise physiology laboratory. Using a randomized, crossover design, four laboratory topics were delivered in either a blended or traditional format. For blended laboratories, content was offloaded to self-paced video demonstrations (∼15 min). Laboratory section 1 (n = 16) completed blended laboratories for 1) neuromuscular power and 2) blood lactate, whereas section 2 (n = 17) completed blended laboratories for 1) maximal O2 consumption and 2) muscle electromyography. Both sections completed the same assignments (scored in a blinded manner using a standardized rubric) and practicum exams (evaluated by two independent investigators). Pre- and postcourse surveys were used to assess student perceptions. Most students (∼79%) watched videos for both blended laboratories. Assignment scores did not differ between blended and traditional laboratories (P = 0.62) or between sections (P = 0.91). Practicum scores did not differ between sections (both P > 0.05). At the end of the course, students' perceived value of the blended format increased (P learning key foundational content through video demonstrations before class greatly enhanced their learning of course material compared with a preassigned reading (94% vs. 78%, P Blended exercise physiology laboratories provided an alternative method for delivering content that was favorably perceived by students and did not compromise student performance. Copyright © 2016 The American Physiological Society.

  10. Inter-laboratory exercise on steroid estrogens in aqueous samples

    Energy Technology Data Exchange (ETDEWEB)

    Heath, E., E-mail: ester.heath@ijs.s [Department of Environmental Sciences, Jozef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia); Kosjek, T. [Department of Environmental Sciences, Jozef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia); Andersen, H.R.; Holten Luetzhoft, H.-C. [Department of Environmental Engineering, Technical University of Denmark, Miljoevej 113, DK-2800 Kgs. Lyngby (Denmark); Adolfson Erici, M. [Stockholm University, ITM SE-106 91 Stockholm (Sweden); Coquery, M. [Cemagref, U.R. QELY, F-69336 Lyon (France); Duering, R.-A. [Giessen University, Institute of Soil Science and Soil Conservation, Giessen (Germany); Gans, O. [Umweltbundesamt GmbH, Unit Organic Analysis, Spittelauer Laende 5, 1090 Vienna (Austria); Guignard, C. [CRP Gabriel Lippmann, EVA, 41 rue du Brill, L-4422 Belvaux (Luxembourg); Karlsson, P. [Lantmannen Analycen AB, Research and Development, Sjoehagsgatan 3 Box 905, 5319, Lidkoeping (Sweden); Manciot, F. [CAE VEOLIA ENVIRONMENT, 1 Place de Turenne, 94417 Saint Maurice Cedex (France); Moldovan, Z. [National Institute of Research and Development for Isotopic and Molecular Technology, Mass Spectrometry Department, Str. Donath 65-103, 400293 Cluj-Napoca (Romania); Patureau, D. [INRA, UR50, Laboratoire de Biotechnologie de l' Environnemet (LBE), Avenue des etangs, F-11100 Narbonne (France); Cruceru, L. [Pollution Control Department, National Research Institute for Industrial Ecology (ECOIND), Sos.Panduri 90-92, sector 5, Bucharest (Romania); Sacher, F. [DVGW-Technologiezentrum Wasser, Karlsruher Strasse 84, 76139 Karlsruhe (Germany); Ledin, A. [Department of Environmental Engineering, Technical University of Denmark, Miljoevej 113, DK-2800 Kgs. Lyngby (Denmark)

    2010-03-15

    An inter-laboratory comparison exercise was organized among European laboratories, under the aegis of EU COST Action 636: 'Xenobiotics in Urban Water Cycle'. The objective was to evaluate the performance of testing laboratories determining 'Endocrine Disrupting Compounds' (EDC) in various aqueous matrices. As the main task three steroid estrogens: 17alpha-ethinylestradiol, 17beta-estradiol and estrone were determined in four spiked aqueous matrices: tap water, river water and wastewater treatment plant influent and effluent using GC-MS and LC-MS/MS. Results were compared and discussed according to the analytical techniques applied, the accuracy and reproducibility of the analytical methods and the nature of the sample matrices. Overall, the results obtained in this inter-laboratory exercise reveal a high level of competence among the participating laboratories for the detection of steroid estrogens in water samples indicating that GC-MS as well as LC-MS/MS can equally be employed for the analysis of natural and synthetic hormones. - Herein are presented the results of the first international inter-laboratory study on determination of selected steroid hormones in environmental aqueous samples.

  11. Students' Perception of Self-Efficacy Following Medicinal Chemistry Skills Laboratory Exercises.

    Science.gov (United States)

    Alsharif, Naser Z; Roche, Victoria F; Qi, Yongyue

    2016-06-25

    Objective. To analyze student perceptions of self-efficacy in meeting medicinal chemistry course related educational outcomes and skills following a medicinal chemistry skills laboratory. Methods. Four activities were implemented in a pharmacy skills laboratory (PSL) for second-year pharmacy students. Students (n=121) worked individually on exercises for three of the four activities. Pre/post-laboratory surveys on self-efficacy were administered. The McNemar test was performed to evaluate students' self-efficacy above 70% related to course outcomes before and after the exercises in each activity. An independent t test was conducted to compare the mean of students' responses on meeting course outcomes based on the 70% anchor for the perspective confidence on meeting course outcomes. Results. The post-PSL scores on all self-efficacy questions improved. The majority of students reported skill development in all exercises. Students and clinical faculty qualitative responses indicated they felt exercises were effective. Conclusion. A PSL can serve as a valuable opportunity to address course related educational outcomes and specific skill development and can help students assess their self-efficacy in meeting them.

  12. A New Resource for College Distance Education Astronomy Laboratory Exercises

    Science.gov (United States)

    Vogt, Nicole P.; Cook, Stephen P.; Muise, Amy Smith

    2013-01-01

    This article introduces a set of distance education astronomy laboratory exercises for use by college students and instructors and discusses first usage results. This General Astronomy Education Source exercise set contains eight two-week projects designed to guide students through both core content and mathematical applications of general…

  13. Intercomparison Measurements Exercises of Mobile Radiological Laboratories (invited paper)

    International Nuclear Information System (INIS)

    Martincic, R.

    2000-01-01

    After the reactor accident in Chernobyl, the importance of mobile radiological laboratories became evident and in situ gamma spectrometry became a common method for the rapid detection of gamma emitters in the environment. Since then different institutions in European countries have organised periodic intercomparison exercises of mobile radiological laboratories to improve the measurement methods and the preparedness of emergency monitoring teams. The general objectives of these workshops are to promote the knowledge and to exchange the experiences of emergency monitoring teams that use mobile radiological laboratories, as well as to foster the international harmonisation of emergency monitoring procedures and cooperation among teams. Finally, the results of intercomparison measurements have shown that such exercises are mandatory for rapid, efficient and correct environmental monitoring in nuclear or radiological emergencies. An overview of these intercomparison measurements is given, results from the 1999 intercomparison workshop are presented and lessons learned are discussed. (author)

  14. Laboratory exercises on oscillation modes of pipes

    Science.gov (United States)

    Haeberli, Willy

    2009-03-01

    This paper describes an improved lab setup to study the vibrations of air columns in pipes. Features of the setup include transparent pipes which reveal the position of a movable microphone inside the pipe; excitation of pipe modes with a miniature microphone placed to allow access to the microphone stem for open, closed, or conical pipes; and sound insulation to avoid interference between different setups in a student lab. The suggested experiments on the modes of open, closed, and conical pipes, the transient response of a pipe, and the effect of pipe diameter are suitable for introductory physics laboratories, including laboratories for nonscience majors and music students, and for more advanced undergraduate laboratories. For honors students or for advanced laboratory exercises, the quantitative relation between the resonance width and damping time constant is of interest.

  15. A Guided-Inquiry pH Laboratory Exercise for Introductory Biological Science Laboratories

    Science.gov (United States)

    Snodgrass, Meagan A.; Lux, Nicholas; Metz, Anneke M.

    2011-01-01

    There is a continuing need for engaging inquiry-based laboratory experiences for advanced high school and undergraduate biology courses. The authors describe a guided-inquiry exercise investigating the pH-dependence of lactase enzyme that uses an inexpensive, wide-range buffering system, lactase dietary supplement, over-the-counter glucose test…

  16. INDUSTRIAL RADIOGRAPHY STUDENT GUIDE AND LABORATORY EXERCISES.

    Science.gov (United States)

    Bureau of Adult, Vocational, and Technical Education (DHEW/OE), Washington, DC. Div. of Vocational and Technical Education.

    THIS INSTRUCTOR'S GUIDE TO AN 80-HOUR COURSE IN INDUSTRIAL RADIOGRAPHY IS COORDINATED WITH LESSONS IN THE STUDENT GUIDE AND LABORATORY EXERCISES AND IS BASED ON MATERIAL IN THE COURSE MANUAL, INDUSTRIAL RADIOGRAPHY. THE COURSE IS INTENDED TO TRAIN HIGH SCHOOL GRADUATES AS BEGINNING RADIOGRAPHERS WHO ARE EXPECTED TO BE ABLE TO EXTEND THEIR…

  17. Reliability Of Kraus-Weber Exercise Test As An Evaluation Tool In ...

    African Journals Online (AJOL)

    Reliability Of Kraus-Weber Exercise Test As An Evaluation Tool In Low Back ... strength and flexibility of the back, abdominal, psoas and hamstring muscles. ... Keywords: Kraus-Weber test, low back pain, muscle flexibility, muscle strength.

  18. Laboratory Information Management System Chain of Custody: Reliability and Security

    Science.gov (United States)

    Tomlinson, J. J.; Elliott-Smith, W.; Radosta, T.

    2006-01-01

    A chain of custody (COC) is required in many laboratories that handle forensics, drugs of abuse, environmental, clinical, and DNA testing, as well as other laboratories that want to assure reliability of reported results. Maintaining a dependable COC can be laborious, but with the recent establishment of the criteria for electronic records and signatures by US regulatory agencies, laboratory information management systems (LIMSs) are now being developed to fully automate COCs. The extent of automation and of data reliability can vary, and FDA- and EPA-compliant electronic signatures and system security are rare. PMID:17671623

  19. Effects of exercise on craving and cigarette smoking in the human laboratory.

    Science.gov (United States)

    Kurti, Allison N; Dallery, Jesse

    2014-06-01

    Exercise is increasingly being pursued as a treatment to reduce cigarette smoking. The efficacy of clinical, exercise-based cessation interventions may be enhanced by conducting laboratory studies to determine maximally effective conditions for reducing smoking, and the mechanisms through which the effects on smoking are achieved. The main purpose of this study was to assess whether the effects of exercise on two components of craving (anticipated reward from smoking, anticipated relief from withdrawal) mediated the relationship between exercise and delay (in min) to ad libitum smoking. Experiment 1 (N=21) assessed the effects of exercise intensity (inactivity, low, moderate) on craving components up to 60 min post-exercise. Because moderate-intensity exercise most effectively reduced craving on the reward component, all participants exercised at a moderate intensity in Experiment 2. Using an ABAB within-subjects design, Experiment 2 (N=20) evaluated whether the effects of moderate-intensity exercise on reward and relief components of craving mediated the relationship between exercise and participants' delays (in min) to ad libitum smoking. Delays were significantly longer after exercise (M=21 min) versus inactivity (M=4 min), and the effects of exercise on delay were mediated through the reward component of craving. Future research should continue to explore the mechanisms through which exercise influences behavioral indices of smoking in the human laboratory. Additionally, given the benefits uniquely afforded by exercise-based cessation interventions (e.g., improving mood and other health outcomes), implementing these interventions in clinical settings may contribute substantially to improving public health. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Systemic Exercise-Induced Hypoalgesia Following Isometric Exercise Reduces Conditioned Pain Modulation.

    Science.gov (United States)

    Alsouhibani, Ali; Vaegter, Henrik Bjarke; Hoeger Bement, Marie

    2018-04-03

    Physically active individuals show greater conditioned pain modulation (CPM) compared with less active individuals. Understanding the effects of acute exercise on CPM may allow for a more targeted use of exercise in the management of pain. This study investigated the effects of acute isometric exercise on CPM. In addition, the between-session and within-session reliability of CPM was investigated. Experimental, randomized crossover study. Laboratory at Marquette University. Thirty healthy adults (19.3±1.5 years, 15 males). Subjects underwent CPM testing before and after isometric exercise (knee extension, 30% maximum voluntary contraction for three minutes) and quiet rest in two separate experimental sessions. Pressure pain thresholds (PPTs) at the quadriceps and upper trapezius muscles were assessed before, during, and after ice water immersions. PPTs increased during ice water immersion (i.e., CPM), and quadriceps PPT increased after exercise (P CPM decreased similarly following exercise and quiet rest (P > 0.05). CPM within-session reliability was fair to good (intraclass correlation coefficient [ICC] = 0.43-0.70), and the between-session reliability was poor (ICC = 0.20-0.35). Due to the variability in the systemic exercise-induced hypoalgesia (EIH) response, participants were divided into systemic EIH responders (N = 9) and nonresponders (N = 21). EIH responders experienced attenuated CPM following exercise (P = 0.03), whereas the nonresponders showed no significant change (P > 0.05). Isometric exercise decreased CPM in individuals who reported systemic EIH, suggesting activation of shared mechanisms between CPM and systemic EIH responses. These results may improve the understanding of increased pain after exercise in patients with chronic pain and potentially attenuated CPM.

  1. Exploring Chemical Equilibrium with Poker Chips: A General Chemistry Laboratory Exercise

    Science.gov (United States)

    Bindel, Thomas H.

    2012-01-01

    A hands-on laboratory exercise at the general chemistry level introduces students to chemical equilibrium through a simulation that uses poker chips and rate equations. More specifically, the exercise allows students to explore reaction tables, dynamic chemical equilibrium, equilibrium constant expressions, and the equilibrium constant based on…

  2. Exercise in Inquiry: Critical Thinking in an Inquiry-Based Exercise Physiology Laboratory Course.

    Science.gov (United States)

    DiPasquale, Dana M.; Mason, Cheryl L.; Kolkhorst, Fred W.

    2003-01-01

    Describes an inquiry-based teaching method implemented in an undergraduate exercise physiology laboratory course. Indicates students' strong, positive feelings about the inquiry-based teaching method and shows that inquiry-based learning results in a higher order of learning not typically observed in traditional style classes. This teaching method…

  3. Human factors reliability benchmark exercise: a review

    International Nuclear Information System (INIS)

    Humphreys, P.

    1990-01-01

    The Human Factors Reliability Benchmark Exercise has addressed the issues of identification, analysis, representation and quantification of Human Error in order to identify the strengths and weaknesses of available techniques. Using a German PWR nuclear powerplant as the basis for the studies, fifteen teams undertook evaluations of a routine functional Test and Maintenance procedure plus an analysis of human actions during an operational transient. The techniques employed by the teams are discussed and reviewed on a comparative basis. The qualitative assessments performed by each team compare well, but at the quantification stage there is much less agreement. (author)

  4. Undergraduate Laboratory Exercises Specific to Food Spoilage Microbiology

    Science.gov (United States)

    Snyder, Abigail B.; Worobo, Randy W.; Orta-Ramirez, Alicia

    2016-01-01

    Food spoilage has an enormous economic impact, and microbial food spoilage plays a significant role in food waste and loss; subsequently, an equally significant portion of undergraduate food microbiology instruction should be dedicated to spoilage microbiology. Here, we describe a set of undergraduate microbiology laboratory exercises that focus…

  5. Results of the Interlaboratory Exercise CNS/CIEMAT-05 among Environmental Radioactivity Laboratories (Vegetable Ash)

    International Nuclear Information System (INIS)

    Romero Gonzalez, M. L.; Barrera Izquierdo, M.; Valino Garcia, F.

    2006-01-01

    The document describes the outcome of the CSN/CIEMAT-05 interlaboratory test comparison among environmental radioactivity laboratories. The exercise was organised according to the ISO-43 and the IUPAC I nternational harmonised protocol for the proficiency testing of analytical chemistry laboratories . The exercise has been designed to evaluate the capability of national laboratories to determine environmental levels of radionuclides in vegetable ash samples. The sample has been prepared by the Environmental Radiation Laboratory, from the University of Barcelona, and it contains the following radionuclides: Sr-90, Pu-238, Am-241, Th-230, Pb-210, U-238, Ra-226, K-40, Ra-228, TI-208, Cs- 137 and Co-60. Reference values have been established TROUGH the kind collaboration of three international laboratories of recognized experience: IAEA MEL and IRSN-Orsay. The results of the exercise were computed for 35 participating laboratories and their analytical performance was assessed using the z-score approach. Robust statistics of the participant's results was applied to obtain the median and standard deviation, to achieve a more complete and objetiva study of the laboratories' performance. Some difficulties encountered to dissolve the test sample caused a lower response of analyses involving radiochemical separation, thus some laboratories couldn't apply their routine methods and no conclusions on PU-238, Am-241 and Th-230 performances have been obtained. The exercise has revealed an homogeneous behaviour of laboratories, being statistical parameters from the results close to the reference values. The study has shown that participant laboratories perform radioactive determinations in vegetable ash samples with satisfactory quality levels. (Author) 6 refs

  6. Results of the Interlaboratory Exercise CNS/CIEMAT-04 Among Environmental Radioactivity Laboratories (Aqueous Solution)

    International Nuclear Information System (INIS)

    Romero Gonzalez, M. L.; Barrera Izquierdo, M.

    2004-01-01

    The document describes the outcome of the CSN/CIEMAT-04 interlaboratory test comparison among environmental radioactivity laboratories. The exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC Harmonised Protocol for the proficiency testing of analytical laboratories. Following the issue of the European Community Drinking Water Directive 98/83/EC concerning the quality of water for human consumption, the last inter-comparison exercise was organised by using a water sample, in an attempt to evaluate the performance of the laboratories analysing the required radioactivity parameters (H-3, gross alpha and beta activity and residual beta). The sample (a synthetic drinking water), was prepared at the National Laboratory for Ionising Radiation's Standards (CIEMAT), and contained the following radionuclides ''241 Am, ''239+240 Pu, ''90Sr, ''137 Cs, ''3 H y ''40 K. The results of the exercise were computed for 38 participating laboratories, and their analytical performance was assessed using the z-score approach. Robust statistics of the participant's results was applied to obtain the median and standard deviation, including suspected outliers. The exercise has revealed and homogeneous behaviour of laboratories, being statistical parameters from the results close to the reference values. A raised percentage os satisfactory laboratory performance has been obtained for gross alpha, gross beta and residual beta: 85, 97 and 87% respectively. The study has shown that participant laboratories perform radioactive determinations in drinking water samples with satisfactory quality levels. (Author) 16 refs

  7. Validity and Reliability of the Apple Watch for Measuring\\ud Heart Rate During Exercise

    OpenAIRE

    Khushhal, Alaa; Nichols, Simon; Evans, Will; Gleadall-Siddall, Damien; Page, Richard; O'Doherty, Alasdair; Carroll, Sean; Ingle, Lee; Abt, Grant

    2017-01-01

    We examined the validity and reliability of the Apple Watch heart rate sensor during and in recovery from exercise. Twentyone males completed treadmill exercise while wearing two Apple Watches (left and right wrists) and a Polar S810i monitor (criterion). Exercise involved 5-min bouts of walking, jogging, and running at speeds of 4 km.h − 1, 7 km.h − 1, and 10 km.h − 1, followed by 11 min of rest between bouts. At all exercise intensities the mean bias was trivial. There were very good correl...

  8. Laboratory Exercise: Study of Digestive and Regulatory Processes through the Exploration of Fasted and Postprandial Blood Glucose

    Science.gov (United States)

    Hopper, Mari K.; Maurer, Luke W.

    2013-01-01

    Digestive physiology laboratory exercises often explore the regulation of enzyme action rather than systems physiology. This laboratory exercise provides a systems approach to digestive and regulatory processes through the exploration of postprandial blood glucose levels. In the present exercise, students enrolled in an undergraduate animal…

  9. Reliability of a Simple Physical Therapist Screening Tool to Assess Errors during Resistance Exercises for Musculoskeletal Pain

    DEFF Research Database (Denmark)

    Andersen, Kenneth Jay; Sundstrup, E.; Andersen, L. L.

    2014-01-01

    The main objective was to investigate the intra- and intertester reliability of a simple screening tool assessing errors in exercise execution by visual observation. 38 participants with no previous resistance exercise experience practiced for two weeks four typical upper limb exercises using ela...

  10. Results of the Interlaboratory Exercise CNS/CIEMAT-2008 among Environmental Radioactivity Laboratories (Phosphogypsum)

    International Nuclear Information System (INIS)

    Romero, M. L.; Barrera, M.; Valino, F.

    2010-01-01

    The document describes the outcome of the CSN/CIEMAT-2008 interlaboratory test comparison among environmental radioactivity laboratories. The exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC. Aphosphogypsum material was used as a test sample, in an attempt to evaluate the performance of the laboratories analyzing NORM (Naturally-Occurring Radioactive Materials). The analysis required were: U-238, Th-234, U-234, Th-230, Ra-226, Pb-214, Bi-214, Pb-210, Po-210, Th-232 and U-235, and also gross alpha and gross beta activities. Reference values have been established according to the method of consensus of expert laboratories, with four international laboratories of credited experience: IAEA Seibersdorf, IAEA MEL, IRSN-Orsay and Sta.Teresa ENEA. The results of the exercise were computed for 34 answering laboratories and their analytical performance was assessed using the z-score. Robust statistics of the participants results was applied to obtain the median and standard deviation, to achieve a more complete and objective study of the laboratories performance. The exercise has shown an homogeneous behaviour of laboratories, being statistical parameters from the results close to the assigned Reference Values. Participant laboratories have demonstrated their ability to determine natural radionuclides in phosphogypsum samples (NORM material) with a satisfactory quality level. The scheme has also allowed examining the capability of laboratories to determine the activities of natural radionuclides at the equilibrium. (Author) 10 refs.

  11. Results of the reliability benchmark exercise and the future CEC-JRC program

    International Nuclear Information System (INIS)

    Amendola, A.

    1985-01-01

    As a contribution towards identifying problem areas and for assessing probabilistic safety assessment (PSA) methods and procedures of analysis, JRC has organized a wide-range Benchmark Exercise on systems reliability. This has been executed by ten different teams involving seventeen organizations from nine European countries. The exercise has been based on a real case (Auxiliary Feedwater System of EDF Paluel PWR 1300 MWe Unit), starting from analysis of technical specifications, logical and topological layout and operational procedures. Terms of references included both qualitative and quantitative analyses. The subdivision of the exercise into different phases and the rules adopted allowed assessment of the different components of the spread of the overall results. It appeared that modelling uncertainties may overwhelm data uncertainties and major efforts must be spent in order to improve consistency and completeness of qualitative analysis. After successful completion of the first exercise, CEC-JRC program has planned separate exercises on analysis of dependent failures and human factors before approaching the evaluation of a complete accident sequence

  12. Lower Secondary School Students' Attitudes Toward Computer-Supported Laboratory Exercises

    Directory of Open Access Journals (Sweden)

    Andreja Špernjak

    2010-03-01

    Full Text Available In Science teaching laboratory work is recognized as one of the cornerstones. In school science laboratory work computers can be used as computer supported laboratory (real and as virtual laboratory. In the first case “real” laboratories involve bench top experiments utilizing data acquisition systems while “virtual” laboratory entails interactive simulations and animations. Lower secondary school students in age between 11 and 15 performed three laboratory exercises (Activity of yeast, Gas exchange in breathing, Heart rate as classic, computer-supported and virtual laboratory. As a result of testing we know that all three methods are suitable even for younger students. When they were asked which method they liked the most, their first choice was computer-supported laboratory, followed by classic laboratory, and virtual laboratory at the end. Additionally recognized weak and strong sides of used methods are discussed.

  13. Inspiring and Challenging Laboratory Exercise in Multivariable Control Theory – The Four-rotor Helicopter

    Directory of Open Access Journals (Sweden)

    Dag A. H. Samuelsen

    2012-12-01

    Full Text Available Engineering students in a module on multivariable control theory are given a laboratory exercise for developing their skills in practical implementation of control systems. This is done in an effort to create a more complete module that gives the students experiences in the practical sides of implementing control systems, while still being theoretically challenging and inspiring. Presenting students with this kind of real-life challenges like sub-optimal models, limited processing time and large degree of uncertainty, is a challenging task, partly due to the need of adapting the level of complexity to the student or group of students doing the exercise in order to keep them engaged throughout the exercise, and in part due to the university's need to reduce expenses related to the administration, supervision, and execution of laboratory exercises. The possibility of adapting the complexity of the exercise to each student's skill level is important, both through the design of the exercise and through the students choosing between different models. The eager student might be tempted by the better performing, but more complex models, while the struggling student can find satisfaction in stabilising the aircraft using the less complex models. The laboratory setup presented uses low-cost components, giving low investment and maintenance costs.

  14. Exercise for laboratory comparison of calibration coefficient in 137Cs beam, radiation protection - 2013/2014

    International Nuclear Information System (INIS)

    Cabral, T.S.; Potiens, M.P.A.; Soares, C.M.A.; Silveira, R.R.; Khoury, H.; Borges, J.C.

    2015-01-01

    This work deals with the preliminary results of the second exercise of comparing the radiation monitors calibration laboratories in Brazil. The exercise involved eight laboratories and the measured quantity is the air kerma in a beam of 137 Cs for radioprotection. The exercise was conducted by the LNMRI/IRD, in a star shaped arrangement from October 2013 to July 2015. The largest deviation was 2% of the calibration coefficient that is acceptable for applications in radioprotection. (author)

  15. Regular Exercise Enhances Task-Based Industriousness in Laboratory Rats.

    Directory of Open Access Journals (Sweden)

    Nicholas C Laurence

    Full Text Available Individuals vary greatly in their willingness to select and persist in effortful tasks, even when high-effort will knowingly result in high-reward. Individuals who select and successively complete effortful, goal-directed tasks can be described as industrious. Trying to increase one's industriousness is desirable from a productivity standpoint, yet intrinsically challenging given that effort expenditure is generally aversive. Here we show that in laboratory rats, a basic physical exercise regimen (20 min/day, five days/week is sufficient to increase industriousness across a battery of subsequent testing tasks. Exercised rats outperformed their non-exercised counterparts in tasks designed to tax effort expenditure, strategic decision-making, problem solving and persistence. These increases in performance led to quicker reward obtainment and greater reward gain over time, and could not be accounted for simply by increased locomotor activity. Our results suggest that a basic exercise regimen can enhance effortful goal-directed behaviour in goal-directed tasks, which highlights a potential productivity benefit of staying physically active.

  16. Preliminary Reliability and Validity of an Exercise Benefits and Barriers for Stroke Prevention Scale in an African American Sample.

    Science.gov (United States)

    Aycock, Dawn M; Clark, Patricia C

    2015-01-01

    African Americans are at heightened risk of first stroke, and regular exercise can reduce stroke risk. Benefits and barriers to exercise subscales from 2 instruments were combined to create the Exercise Benefits and Barriers for Stroke Prevention (EBBSP) scale. Reliability and validity of the EBBSP scale were examined in a nonrandom sample of 66 African Americans who were primarily female, average age 43.3 ± 9.4 years, and high school graduates. Both subscales had adequate internal consistency reliability. Factor analysis revealed two factors for each subscale. More benefits and fewer perceived barriers were significantly related to current exercise and future intentions to exercise. The EBBSP scale may be useful in research focused on understanding, predicting, and promoting exercise for stroke prevention in adults.

  17. Absolute and relative reliability of acute effects of aerobic exercise on executive function in seniors

    Directory of Open Access Journals (Sweden)

    Lars Donath

    2017-10-01

    Full Text Available Abstract Background Aging is accompanied by a decline of executive function. Aerobic exercise training induces moderate improvements of cognitive domains (i.e., attention, processing, executive function, memory in seniors. Most conclusive data are obtained from studies with dementia or cognitive impairment. Confident detection of exercise training effects requires adequate between-day reliability and low day-to-day variability obtained from acute studies, respectively. These absolute and relative reliability measures have not yet been examined for a single aerobic training session in seniors. Methods Twenty-two healthy and physically active seniors (age: 69 ± 3 y, BMI: 24.8 ± 2.2, VO2peak: 32 ± 6 mL/kg/bodyweight were enrolled in this randomized controlled cross-over study. A repeated between-day comparison [i.e., day 1 (habituation vs. day 2 & day 2 vs. day 3] of executive function testing (Eriksen-Flanker-Test, Stroop-Color-Test, Digit-Span, Five-Point-Test before and after aerobic cycling exercise at 70% of the heart rate reserve [0.7 × (HRmax – HRrest] was conducted. Reliability measures were calculated for pre, post and change scores. Results Large between-day differences between day 1 and 2 were found for reaction times (Flanker- and Stroop Color testing and completed figures (Five-Point test at pre and post testing (0.002 < p < 0.05, 0.16 < ɳp 2 < 0.38. These differences notably declined when comparing day 2 and 3. Absolute between days variability (CoV dropped from 10 to 5% when comparing day 2 vs. day 3 instead of day 1 vs. day 2. Also ICC ranges increased from day 1 vs. day 2 (0.65 < ICC < 0.87 to day 2 vs. day 3 (0.40 < ICC < 0.93. Interestingly, reliability measures for pre-post change scores were low (0.02 < ICC < 0.71. These data did not improve when comparing day 2 with day 3. During inhibition tests, reaction times showed excellent reliability values compared to the poor to fair reliability of

  18. Adaptation of the Godin Leisure-Time Exercise Questionnaire into Turkish: The Validity and Reliability Study

    Directory of Open Access Journals (Sweden)

    Emine Sari

    2016-01-01

    Full Text Available This study was conducted with the aim of determining whether the Turkish form of the “Leisure-Time Exercise Questionnaire” developed by Godin is a valid and reliable tool for diabetic patients in Turkey. The study was conducted as a methodological research on 300 diabetic patients in Turkey. The linguistic equivalence of the questionnaire was assessed through the back-translation method, while its content validity was assessed through obtaining expert opinions. Cronbach’s alpha value was found to assess the reliability of the questionnaire. The test-retest analysis and the correlation between independent observers were examined. The content validity index (CVI was found to be .82 according to the expert assessments, and no statistical difference was found between them (Kendall’s W=.17, p=.235. Cronbach’s alpha was found to be α=.64, the result of the test-retest analysis was r=.97, and the correlation between independent observers (ICC was .98. This study found that the Turkish form of the Leisure-Time Exercise Questionnaire is a valid and reliable tool that can be used to define and assess the exercise behaviors of Turkish diabetic patients.

  19. Survey of methods used to asses human reliability in the human factors reliability benchmark exercise

    International Nuclear Information System (INIS)

    Poucet, A.

    1988-01-01

    The Joint Research Centre of the European Commission has organised a Human Factors Reliability Benchmark Exercise (HF-RBE) with the aim to assess the state-of-the-art in human reliability modelling and assessment. Fifteen teams from eleven countries, representing industry, utilities, licensing organisations and research institutes, participate in the HF-RBE, which is organised around two study cases: (1) analysis of routine functional test and maintenance procedures, with the aim to assess the probability of test-induced failures, the probability of failures to remain unrevealed, and the potential to initiate transients because of errors performed in the test; and (2) analysis of human actions during an operational transient, with the aim to assess the probability that the operators will correctly diagnose the malfunctions and take proper corrective action. The paper briefly reports how the HF-RBE was structured and gives an overview of the methods that have been used for predicting human reliability in both study cases. The experience in applying these methods is discussed and the results obtained are compared. (author)

  20. Focusing on the Hard parts: A Biomechanics Laboratory Exercise

    Science.gov (United States)

    Fingerut, Jonathan; Orbe, Kristina; Flynn, Daniel; Habdas, Piotr

    2013-01-01

    As part of a biomechanics course aimed at both upper-division Biology and Physics majors, this laboratory exercise introduces students to the ingenious ways in which organisms vary the composition and form of support and defensive structures such as bone and shell to maximize their strength while minimizing the energetic cost needed to produce…

  1. Laboratory Information Management System Chain of Custody: Reliability and Security

    OpenAIRE

    Tomlinson, J. J.; Elliott-Smith, W.; Radosta, T.

    2006-01-01

    A chain of custody (COC) is required in many laboratories that handle forensics, drugs of abuse, environmental, clinical, and DNA testing, as well as other laboratories that want to assure reliability of reported results. Maintaining a dependable COC can be laborious, but with the recent establishment of the criteria for electronic records and signatures by US regulatory agencies, laboratory information management systems (LIMSs) are now being developed to fully automate COCs. The extent of a...

  2. Tested Studies for Laboratory Teaching. Proceedings of the Workshop/Conference of the Association for Biology Laboratory Education (ABLE) (13th, Laramie, Wyoming, June 11-15, 1991). Volume 13.

    Science.gov (United States)

    Goldman, Corey A., Ed.

    The focus of the Association for Biology Laboratory Education (ABLE) is to improve the undergraduate biology laboratory experience by promoting the development and dissemination of interesting, innovative, and reliable laboratory exercises. This proceedings volume contains 10 papers: "Testing Issues of Foraging and Flocking Behavior" (C. C.…

  3. Real-time laboratory exercises to test contingency plans for classical swine fever: experiences from two national laboratories

    DEFF Research Database (Denmark)

    Koenen, K.; Uttenthal, Åse; Meindl-Böhmer, A.

    2007-01-01

    In order to adequately and efficiently handle outbreaks of contagious diseases such as classical swine fever (CSF), foot and mouth disease or highly pathogenic avian influenza, competent authorities and the laboratories involved have to be well prepared and must be in possession of functioning....... It is essential that these plans are established during ‘peace-time’ and are reviewed regularly. This paper provides suggestions on how to perform laboratory exercises to test preparedness and describes the experiences of two national reference laboratories for CSF. The major lesson learnt was the importance...

  4. Diurnal variation and reliability of the urine lactate concentration after maximal exercise.

    Science.gov (United States)

    Nikolaidis, Stefanos; Kosmidis, Ioannis; Sougioultzis, Michail; Kabasakalis, Athanasios; Mougios, Vassilis

    2018-01-01

    The postexercise urine lactate concentration is a novel valid exercise biomarker, which has exhibited satisfactory reliability in the morning hours under controlled water intake. The aim of the present study was to investigate the diurnal variation of the postexercise urine lactate concentration and its reliability in the afternoon hours. Thirty-two healthy children (11 boys and 21 girls) and 23 adults (13 men and 10 women) participated in the study. All participants performed two identical sessions of eight 25 m bouts of maximal freestyle swimming executed every 2 min with passive recovery in between. These sessions were performed in the morning and afternoon and were separated by 3-4 days. Adults performed an additional afternoon session that was also separated by 3-4 days. All swimmers drank 500 mL of water before and another 500 mL after each test. Capillary blood and urine samples were collected before and after each test for lactate determination. Urine creatinine, urine density and body water content were also measured. The intraclass correlation coefficient was used as a reliability index between the morning and afternoon tests, as well as between the afternoon test and retest. Swimming performance and body water content exhibited excellent reliability in both children and adults. The postexercise blood lactate concentration did not show diurnal variation, showing a good reliability between the morning and afternoon tests, as well as high reliability between the afternoon test and retest. The postexercise urine density and lactate concentration were affected by time of day. However, when lactate was normalized to creatinine, it exhibited excellent reliability in children and good-to-high reliability in adults. The postexercise urine lactate concentration showed high reliability between the afternoon test and retest, independent of creatinine normalization. The postexercise blood and urine lactate concentrations were significantly correlated in all

  5. A Biology Laboratory Exercise Using Macromolecule Assays to Distinguish Four Types of Milk

    Directory of Open Access Journals (Sweden)

    Charlotte W. Pratt

    2011-03-01

    Full Text Available One of the drawbacks of cookbook-style laboratory exercises for General Biology courses is that students are not challenged to develop skills in scientific reasoning, such as formulating hypotheses and designing and carrying out experiments. Several traditional laboratory curricula include exercises involving semi-quantitative colorimetric assays to detect proteins (biuret test, reducing sugars (Benedict’s test, starch (Lugol’s test, and lipids (Sudan red test in a variety of easily prepared solutions (glucose, albumin, glycine, etc. and familiar food items (lemon juice, cornstarch, egg white, etc.. An extension of this lab exercise was developed to allow students to use their knowledge of the macromolecule assays to design an experiment to distinguish four types of “milk”: whole milk, skim milk, cream, and soy milk (rice milk or almond milk could also be included.

  6. Tested Studies for Laboratory Teaching. Proceedings of the Workshop/Conference of the Association for Biology Laboratory Education (ABLE) (15th, Toronto, Ontario, Canada, June 8-12, 1993). Volume 15.

    Science.gov (United States)

    Goldman, Corey A., Ed.

    The focus of the Association for Biology Laboratory Education (ABLE) is to improve the undergraduate biology laboratory experience by promoting the development and dissemination of interesting, innovative, and reliable laboratory exercises. This proceedings volume contains 18 papers: "Human DNA Fingerprinting by Polymerase Chain Reaction" (M. V.…

  7. An inter- laboratory proficiency testing exercise for rabies diagnosis in Latin America and the Caribbean.

    Directory of Open Access Journals (Sweden)

    Alfonso Clavijo

    2017-04-01

    Full Text Available The direct fluorescent antibody test (DFA, is performed in all rabies reference laboratories across Latin America and the Caribbean (LAC. Despite DFA being a critical capacity in the control of rabies, there is not a standardized protocol in the region. We describe the results of the first inter-laboratory proficiency exercise of national rabies laboratories in LAC countries as part of the regional efforts towards dog-maintained rabies elimination in the American region. Twenty three laboratories affiliated to the Ministries of Health and Ministries of Agriculture participated in this exercise. In addition, the laboratories completed an online questionnaire to assess laboratory practices. Answers to the online questionnaire indicated large variability in the laboratories throughput, equipment used, protocols availability, quality control standards and biosafety requirements. Our results will inform actions to improve and harmonize laboratory rabies capacities across LAC in support for the regional efforts towards elimination of dog-maintained rabies.

  8. A soil sampling intercomparison exercise for the ALMERA network

    Energy Technology Data Exchange (ETDEWEB)

    Belli, Maria [Istituto Superiore per la Protezione e la Ricerca Ambientale (ISPRA), Via di Castel Romano 100, I-00128 Roma (Italy)], E-mail: maria.belli@apat.it; Zorzi, Paolo de [Istituto Superiore per la Protezione e la Ricerca Ambientale (ISPRA), Via di Castel Romano 100, I-00128 Roma (Italy)], E-mail: paolo.dezorzi@isprambiente.it; Sansone, Umberto [International Atomic Energy Agency (IAEA), Agency' s Laboratories Seibersdorf, A-2444 Seibersdorf (Austria)], E-mail: u.sansone@iaea.org; Shakhashiro, Abduhlghani [International Atomic Energy Agency (IAEA), Agency' s Laboratories Seibersdorf, A-2444 Seibersdorf (Austria)], E-mail: a.shakhashiro@iaea.org; Gondin da Fonseca, Adelaide [International Atomic Energy Agency (IAEA), Agency' s Laboratories Seibersdorf, A-2444 Seibersdorf (Austria)], E-mail: a.gondin-da-fonseca-azeredo@iaea.org; Trinkl, Alexander [International Atomic Energy Agency (IAEA), Agency' s Laboratories Seibersdorf, A-2444 Seibersdorf (Austria)], E-mail: a.trinkl@iaea.org; Benesch, Thomas [International Atomic Energy Agency (IAEA), Agency' s Laboratories Seibersdorf, A-2444 Seibersdorf (Austria)], E-mail: t.benesch@iaea.org

    2009-11-15

    Soil sampling and analysis for radionuclides after an accidental or routine release is a key factor for the dose calculation to members of the public, and for the establishment of possible countermeasures. The IAEA organized for selected laboratories of the ALMERA (Analytical Laboratories for the Measurement of Environmental Radioactivity) network a Soil Sampling Intercomparison Exercise (IAEA/SIE/01) with the objective of comparing soil sampling procedures used by different laboratories. The ALMERA network is a world-wide network of analytical laboratories located in IAEA member states capable of providing reliable and timely analysis of environmental samples in the event of an accidental or intentional release of radioactivity. Ten ALMERA laboratories were selected to participate in the sampling exercise. The soil sampling intercomparison exercise took place in November 2005 in an agricultural area qualified as a 'reference site', aimed at assessing the uncertainties associated with soil sampling in agricultural, semi-natural, urban and contaminated environments and suitable for performing sampling intercomparison. In this paper, the laboratories sampling performance were evaluated.

  9. A soil sampling intercomparison exercise for the ALMERA network

    International Nuclear Information System (INIS)

    Belli, Maria; Zorzi, Paolo de; Sansone, Umberto; Shakhashiro, Abduhlghani; Gondin da Fonseca, Adelaide; Trinkl, Alexander; Benesch, Thomas

    2009-01-01

    Soil sampling and analysis for radionuclides after an accidental or routine release is a key factor for the dose calculation to members of the public, and for the establishment of possible countermeasures. The IAEA organized for selected laboratories of the ALMERA (Analytical Laboratories for the Measurement of Environmental Radioactivity) network a Soil Sampling Intercomparison Exercise (IAEA/SIE/01) with the objective of comparing soil sampling procedures used by different laboratories. The ALMERA network is a world-wide network of analytical laboratories located in IAEA member states capable of providing reliable and timely analysis of environmental samples in the event of an accidental or intentional release of radioactivity. Ten ALMERA laboratories were selected to participate in the sampling exercise. The soil sampling intercomparison exercise took place in November 2005 in an agricultural area qualified as a 'reference site', aimed at assessing the uncertainties associated with soil sampling in agricultural, semi-natural, urban and contaminated environments and suitable for performing sampling intercomparison. In this paper, the laboratories sampling performance were evaluated.

  10. Glucose Transport in Cultured Animal Cells: An Exercise for the Undergraduate Cell Biology Laboratory

    Science.gov (United States)

    Ledbetter, Mary Lee S.; Lippert, Malcolm J.

    2002-01-01

    Membrane transport is a fundamental concept that undergraduate students of cell biology understand better with laboratory experience. Formal teaching exercises commonly used to illustrate this concept are unbiological, qualitative, or intricate and time consuming to prepare. We have developed an exercise that uses uptake of radiolabeled nutrient…

  11. The Swedish Exercise Self-Efficacy Scale (ESES-S): reliability and validity in a rheumatoid arthritis population.

    Science.gov (United States)

    Nessen, Thomas; Demmelmaier, Ingrid; Nordgren, Birgitta; Opava, Christina H

    2015-01-01

    The aim of the present study was to investigate aspects of reliability and validity of the Exercise Self-Efficacy Scale (ESES-S) in a rheumatoid arthritis (RA) population. A total of 244 people with RA participating in a physical activity study were included. The six-item ESES-S, exploring confidence in performing exercise, was assessed for test-retest reliability over 4-6 months, and for internal consistency. Construct validity investigated correlation with similar and other constructs. An intraclass correlation coefficient (ICC) of 0.59 (95% CI 0.37-0.73) was found for 84 participants with stable health perceptions between measurement occasions. Cronbach's alpha coefficients of 0.87 and 0.89 were found at the first and second measurements. Corrected item-total correlation single ESES-S items ranged between 0.53 and 0.73. Construct convergent validity for the ESES-S was partly confirmed by correlations with health-enhancing physical activity and outcome expectations respectively (Pearson's r = 0.18, p exercise is crucial for management of symptoms and co-morbidity in rheumatoid arthritis. Self-efficacy for exercise is important to address in rehabilitation as it regulates exercise motivation and behavior. Measurement properties of self-efficacy scales need to be assessed in specific populations and different languages.

  12. After Action Report: Idaho National Laboratory Annual Exercise August 1, 2014

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, Scott V. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-09-01

    On August 1, 2014, Idaho National Laboratory (INL), in coordination with the State of Idaho, local jurisdictions, Department of Energy (DOE) Idaho Operations Office, and DOE Headquarters (DOE-HQ), conducted the annual emergency exercise to demonstrate the ability to implement the requirements of DOE O 151.1C, “Comprehensive Emergency Management System.” The INL contractor, Battelle Energy Alliance, LLC (BEA), in coordination with other INL contractors, conducted operations and demonstrated appropriate response measures to mitigate an event and protect the health and safety of personnel, the environment, and property. Offsite response organizations participated to demonstrate appropriate response measures. Report data were collected from multiple sources, which included documentation generated during exercise response, player critiques conducted immediately after terminating the exercise, personnel observation sheets, and evaluation critiques. Evaluation of this exercise served as a management assessment of the performance of the INL Emergency Management Program (IAS141618).

  13. Practical Bioremediation Course – Laboratory Exercises on Biodegradation of Cationic Surfactant

    Directory of Open Access Journals (Sweden)

    Tomislav Ivankovic

    2015-02-01

    Full Text Available 0 From the perspective of the lab exercises leader and teaching assistant for the Bioremediation course, it was very difficult to design and conduct a set of exercises that would fit the course curriculum and satisfactorily demonstrate bioremediation basics through practical laboratory work. Thus, Bioremediation course students designed the experiment with the help of the teaching assistant; a simulation of possible bioremediation of “Jarun” lake in Zagreb, Croatia, if contaminated with cationic surfactant. The experiment nicely showed how natural bioremediation differs from engineered bioremediation and the levels of success between different types of engineered bioremediation. The laboratory exercises were designed to be interesting and the results perceivable to the students.  Editor's Note:The ASM advocates that students must successfully demonstrate the ability to explain and practice safe laboratory techniques. For more information, read the laboratory safety section of the ASM Curriculum Recommendations: Introductory Course in Microbiology and the Guidelines for Biosafety in Teaching Laboratories, available at www.asm.org. The Editors of JMBE recommend that adopters of the protocols included in this article follow a minimum of Biosafety Level 2 practices. Normal 0 21 false false false HR X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Cambria","serif"; mso-ascii-font-family:Cambria; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Cambria; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}

  14. Results Assessment of Intercomparison Exercise CSN/CIEMAT-2011 among Spanish National Laboratories of Environmental Radioactivity (Water)

    International Nuclear Information System (INIS)

    Gascó, C.; Trinidad, J. A.; Llauradó, M.

    2015-01-01

    This report describes the results assessment of the intercomparsion exercise among environmental radioactivity laboratories, organised by Spanish Regulatory Institution (CSN) and prepared and evaluated by UAB and CIEMAT respectively. The exercise has been carried out following the international standards ISO-43 and ISO/IUPAC that provide a useful guide to perform proficiency tests and inter-laboratories comparisons. The selected matrix for this year (2011) was deionized water, simulating drinking water, that was enriched with artificial radionuclides (Cs-137, Co-60, Fe-55, Ni-63, Sr-90, Am-241 and Pu-238) and contained natural radionuclides (U-234, U-238, U-natural, Pb-210, Po-210, Th-230, Ra-226 and K-40) at environmental level of activity concentration. A second matrix of deionized water was prepared with I-129 and C-14. The z-score test was applied to determine how much the laboratories differ from the reference value. The reference value for this exercise was the median of the results from the different laboratories and their standard deviations to achieve a more complete and objective study of the laboratories performance. The participant laboratories have demonstrated a satisfactory quality level for measuring the natural and artificial radionuclides content in this matrix. The study has showed a homogeneous behaviour of the laboratories.

  15. Absolute and relative reliability of acute effects of aerobic exercise on executive function in seniors.

    Science.gov (United States)

    Donath, Lars; Ludyga, Sebastian; Hammes, Daniel; Rossmeissl, Anja; Andergassen, Nadin; Zahner, Lukas; Faude, Oliver

    2017-10-25

    Aging is accompanied by a decline of executive function. Aerobic exercise training induces moderate improvements of cognitive domains (i.e., attention, processing, executive function, memory) in seniors. Most conclusive data are obtained from studies with dementia or cognitive impairment. Confident detection of exercise training effects requires adequate between-day reliability and low day-to-day variability obtained from acute studies, respectively. These absolute and relative reliability measures have not yet been examined for a single aerobic training session in seniors. Twenty-two healthy and physically active seniors (age: 69 ± 3 y, BMI: 24.8 ± 2.2, VO 2peak : 32 ± 6 mL/kg/bodyweight) were enrolled in this randomized controlled cross-over study. A repeated between-day comparison [i.e., day 1 (habituation) vs. day 2 & day 2 vs. day 3] of executive function testing (Eriksen-Flanker-Test, Stroop-Color-Test, Digit-Span, Five-Point-Test) before and after aerobic cycling exercise at 70% of the heart rate reserve [0.7 × (HR max - HR rest )] was conducted. Reliability measures were calculated for pre, post and change scores. Large between-day differences between day 1 and 2 were found for reaction times (Flanker- and Stroop Color testing) and completed figures (Five-Point test) at pre and post testing (0.002 seniors can be presumed.

  16. Methods of Estimation the Reliability and Increasing the Informativeness of the Laboratory Results (Analysis of the Laboratory Case of Measurement the Indicators of Thyroid Function

    Directory of Open Access Journals (Sweden)

    N A Kovyazina

    2014-06-01

    Full Text Available The goal of the study was to demonstrate the multilevel laboratory quality management system and point at the methods of estimating the reliability and increasing the amount of information content of the laboratory results (on the example of the laboratory case. Results. The article examines the stages of laboratory quality management which has helped to estimate the reliability of the results of determining Free T3, Free T4 and TSH. The measurement results are presented by the expanded uncertainty and the evaluation of the dynamics. Conclusion. Compliance with mandatory measures for laboratory quality management system enables laboratories to obtain reliable results and calculate the parameters that are able to increase the amount of information content of laboratory tests in clinical decision making.

  17. CCF-RBE common cause failure reliability benchmark exercise

    International Nuclear Information System (INIS)

    Poucet, A.; Amendola, A.; Cacciabue, P.C.

    1987-01-01

    This report summarizes results, obtained by the participants in the Reliability Benchmark Exercise on Common Cause Failures (CCF-RBE). The reference power plant of the CCF-RBE was the NPP at Grohnde (KWG): it is a 1300 MW PWR plant of KWU design and operated by the utility Preussen Elektra. The systems studied were the Start-up and Shut-down system (RR/RL) and the Emergency Feedwater System (RS) both systems that can feed water into the steam generators in the emergency power mode. The CCF-RBE was organized in two phases: 1. The first phase: during which all participants have performed an analysis on the complete system as defined by the assumed boundaries, i.e. the Start-up and Shut-down system (RR/RL) and the Emergency Feedwater System (RS). 2. The second phase: in which the scope was limited to the RS system. This limitation in scope was agreed upon in the discussion on the results of the first phase, which showed that, within the boundaries of the exercise, RR/RL and RS systems could be considered independent of each other. This report gives an overview of the works carried out, the results obtained and the conclusions and lessons that could be drawn from the CCF-RBE

  18. Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability.

    Science.gov (United States)

    Stoller, Oliver; Schindelholz, Matthias; Hunt, Kenneth J

    2016-01-01

    Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP-root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. All criteria for feasibility were achieved. Mean V'O2peak was 106±9% of predicted V'O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V'O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V'O2max

  19. Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability.

    Directory of Open Access Journals (Sweden)

    Oliver Stoller

    Full Text Available Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC. The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations.Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP-root mean square error. Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC, standard error of the measurement (SEM, and minimal detectable change (MDC. Mean differences, limits of agreement, and coefficients of variation (CoV were estimated to assess repeatability.All criteria for feasibility were achieved. Mean V'O2peak was 106±9% of predicted V'O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V'O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects. Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%. Repeatability for the primary outcomes was good (CoV ≤ 0.12.RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V'O2

  20. Food Microbiology--Design and Testing of a Virtual Laboratory Exercise

    Science.gov (United States)

    Flint, Steve; Stewart, Terry

    2010-01-01

    A web-based virtual laboratory exercise in identifying an unknown microorganism was designed for use with a cohort of 3rd-year university food-technology students. They were presented with a food-contamination case, and then walked through a number of diagnostic steps to identify the microorganism. At each step, the students were asked to select 1…

  1. Results of the Interlaboratory Exercise CSN/CIEMAT-02 Among Environmental Radioactivity Laboratories (Sea Fish)

    International Nuclear Information System (INIS)

    Romero Gonzalez, M.L.

    2003-01-01

    The document describes the outcome of the CSN/CIEMAT-02 interlaboratory test comparison among environmental radioactivity laboratories. The exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC Harmonized Protocol for the proficiency testing of analytical laboratories. The test sample was a reference materials provided by the IAEA-MEL (IAE Marine Environmental Laboratory, Monaco), a sea fish containing environmental levels of U-238, U-234, K-40, Pb-210, Ra-226, Sr-90, Cs-137, Co-60, Pu-(239+240), Am-241 and Tc-99. The results of the exercise were computed for 32 participating laboratories, and their analytical performance was assessed using the z-score approach. A raised percentage of satisfactory laboratory performance has been obtained for all the analysis, being the best performance in gamma measurements. The laboratories have made an effort to calculate the combined uncertainty of the radiochemical determinations. Most of the laboratories have demonstrated its competence in performing the study analysis and also the adequate measuring capability of their detection equipment even in conditions close to detection limits. The study has shown the capacity of participant laboratories to perform radioactive determinations in environmental sea fish samples with satisfactory quality levels. (Author) 6 refs

  2. Evaluation of cardiovascular risk-lowering health benefits accruing from laboratory-based, community-based and exercise-referral exercise programmes.

    Science.gov (United States)

    Webb, R; Thompson, J E S; Ruffino, J-S; Davies, N A; Watkeys, L; Hooper, S; Jones, P M; Walters, G; Clayton, D; Thomas, A W; Morris, K; Llewellyn, D H; Ward, M; Wyatt-Williams, J; McDonnell, B J

    2016-01-01

    To evaluate the ability of community-based exercise programmes to facilitate public participation in exercise and hence improved cardiovascular health, we assessed the respective impacts of: a continuously monitored exercise programme based within our university (study 1); a Valleys Regional Park-facilitated community-based outdoor exercise programme (study 2); a Wales National Exercise Referral Scheme-delivered exercise-referral programme (study 3). Biomolecular (monocytic PPARγ target gene expression), vascular haemodynamic (central/peripheral blood pressure, arterial stiffness), clinical (insulin sensitivity, blood lipids) and anthropometric (body mass index, waist circumference, heart rate) parameters were investigated using RT-PCR, applanation tonometry, chemical analysis and standard anthropometric techniques. In studies 1-3, 22/28, 32/65 and 11/14 participants adhered to their respective exercise programmes, and underwent significant increases in physical activity levels. Importantly, beneficial effects similar to those seen in our previous studies (eg, modulations in expression of monocytic PPARγ target genes, decreases in blood pressure/arterial stiffness, improvements in blood lipids/insulin sensitivity) were observed (albeit to slightly differing extents) only in participants who adhered to their respective exercise programmes. While study 1 achieved more intense exercise and more pronounced beneficial effects, significant cardiovascular risk-lowering health benefits related to biomolecular markers, blood pressure, arterial stiffness and blood lipids were achieved via community/referral-based delivery modes in studies 2 and 3. Because cardiovascular health benefits were observed in all 3 studies, we conclude that the majority of benefits previously reported in laboratory-based studies can also be achieved in community-based/exercise-referral settings. These findings may be of use in guiding policymakers with regard to introduction and/or continued

  3. Proton beam therapy: reliability of the synchrocyclotron at the Harvard Cyclotron Laboratory

    International Nuclear Information System (INIS)

    Sisterson, J.M.; Cascio, E.; Koehler, A.M.; Johnson, K.N.

    1991-01-01

    The reliability of the synchrocyclotron at Harvard Cyclotron Laboratory has been studied over the period 1980-1989 to see if proton beam therapy can compare in reliability to linear accelerators used in radiation therapy departments. Breakdowns in relation to patient load are reviewed in outline. (U.K.)

  4. Results Assessment of Intercomparison Exercise CSN/CIEMAT-2013 among Spanish National Laboratories of Environmental Radioactivity (Air)

    International Nuclear Information System (INIS)

    Trinidad, J. A.; Gascó, C.; Llauradó, M.

    2015-01-01

    This report describes the results assessment of the intercomparsion exercise among environmental radioactivity laboratories, organised by Spanish Regulatory Institution (CSN) and prepared and evaluated by UB and CIEMAT respectively. The exercise has been carried out following the international standards ISO-43 and ISO/IUPAC that provide a useful guide to perform proficiency tests and inter-laboratories comparisons. The selected matrix for this year (2013) was filters, which was enriched with artificial radionuclides (137Cs, 60Co and 57Co) and contained natural radionuclides (234U, 238U, U-natural 230Th, 226Ra, 210Pb, 234Th, 214Bi and 214Pb) at environmental level of activity concentration. Three commonly used filters (47 mm diameter, 44x44 cm2 and 20x25 cm2) were prepared. Two 47 mm diameter filter were prepared to separate 226Ra and 210Pb analysis. The z-score test was applied to determine how much the laboratories differ from the reference value. The reference value for this exercise was the median of the results from the different laboratories and their standard deviations to achieve a more complete and objective study of the laboratories performance. The participant laboratories have demonstrated a satisfactory quality level for measuring the natural and artificial radionuclides content in this matrix. The study has showed a homogeneous behaviour of the laboratories

  5. Results Assessment of Intercomparison Exercise CSN/CIEMAT-2012 among Spanish National Laboratories of Environmental Radioactivity (Soil)

    International Nuclear Information System (INIS)

    Trinidad, J. A.; Gascó, C.; Llauradó, M.

    2015-01-01

    This report describes the results assessment of the intercomparsion exercise among environmental radioactivity laboratories, organised by Spanish Regulatory Institution (CSN) and prepared and evaluated by UB and CIEMAT respectively. The exercise has been carried out following the international standards ISO-43 and ISO/IUPAC that provide a useful guide to perform proficiency tests and inter-laboratories comparisons. The selected matrix for this year (2012) was soil, that was enriched with artificial radionuclides (137Cs, 60Co, 55Fe, 63Ni, 90Sr, 241Am, 239+240Pu and 238Pu) and contained natural radionuclides (234U, 238U, U-natural 230Th, 226Ra, 210Pb, 228Ra, 228Ac, 234Th, 214Bi, 214Pb, 212Pb, 208Tl and 40K) at environmental level of activity concentration. Two soil matrixes were prepared in order to separate 55Fe and 63Ni analysis. The z-score test was applied to determine how much the laboratories differ from the reference value. The reference value for this exercise was the median of the results from the different laboratories and their standard deviations to achieve a more complete and objective study of the laboratories performance. The participant laboratories have demonstrated a satisfactory quality level for measuring the natural and artificial radionuclides content in this matrix. The study has showed a homogeneous behaviour of the laboratories.

  6. Animal Galloping and Human Hopping: An Energetics and Biomechanics Laboratory Exercise

    Science.gov (United States)

    Lindstedt, Stan L.; Mineo, Patrick M.; Schaeffer, Paul J.

    2013-01-01

    This laboratory exercise demonstrates fundamental principles of mammalian locomotion. It provides opportunities to interrogate aspects of locomotion from biomechanics to energetics to body size scaling. It has the added benefit of having results with robust signal to noise so that students will have success even if not "meticulous" in…

  7. Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review.

    Science.gov (United States)

    Ratter, Julia; Radlinger, Lorenz; Lucas, Cees

    2014-09-01

    Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Systematic review of studies of the psychometric properties of exercise tests. People older than 18 years with chronic pain, fibromyalgia and chronic fatigue disorders. Studies of the measurement properties of tests of physical capacity in people with chronic pain, fibromyalgia or chronic fatigue disorders were included. Studies were required to report: reliability coefficients (intraclass correlation coefficient, alpha reliability coefficient, limits of agreements and Bland-Altman plots); validity coefficients (intraclass correlation coefficient, Spearman's correlation, Kendal T coefficient, Pearson's correlation); or dropout rates. Fourteen studies were eligible: none had low risk of bias, 10 had unclear risk of bias and four had high risk of bias. The included studies evaluated: Åstrand test; modified Åstrand test; Lean body mass-based Åstrand test; submaximal bicycle ergometer test following another protocol other than Åstrand test; 2-km walk test; 5-minute, 6-minute and 10-minute walk tests; shuttle walk test; and modified symptom-limited Bruce treadmill test. None of the studies assessed maximal exercise tests. Where they had been tested, reliability and validity were generally high. Dropout rates were generally acceptable. The 2-km walk test was not recommended in fibromyalgia. Moderate evidence was found for reliability, validity and acceptability of submaximal exercise tests in patients with chronic pain, fibromyalgia or chronic fatigue. There is no evidence about maximal exercise tests in patients with chronic pain, fibromyalgia and chronic fatigue. Copyright © 2014. Published by Elsevier B.V.

  8. Flexibility and reliability in long-term planning exercises dedicated to the electricity sector

    Energy Technology Data Exchange (ETDEWEB)

    Maizi, Nadia; Drouineau, Mathilde; Assoumou, Edi; Mazauric, Vincent

    2010-09-15

    Long-term planning models are useful to build plausible options for future energy systems and must consequently address the technological feasibility and associated cost of these options. This paper focuses on the electricity sector and on problems of flexibility and reliability in power systems in order to improve results provided by long-term planning exercises: flexibility needs are integrated as an additional criterion for new investment decisions and, reliability requirements are assessed through the level of electrical losses they induced and a related cost. These approaches are implemented in a long-term planning model and demonstrated through a study of the Reunion Island.

  9. How to Generate Understanding of the Scientific Process in Introductory Biology: A Student-Designed Laboratory Exercise on Yeast Fermentation

    Science.gov (United States)

    Collins, Linda T.; Bell, Rebekah P.

    2004-01-01

    Heavy faculty teaching loads and limited funds biology teachers designed certain objectives in order to increase the understandability of the subject matter of the laboratory exercises they write. In relation to these objectives an old "cookbook" laboratory exercise on yeast fermentation is introduced which involve students asking questions,…

  10. Are Chicken Embryos Endotherms or Ectotherms? A Laboratory Exercise Integrating Concepts in Thermoregulation and Metabolism

    Science.gov (United States)

    Hiebert, Sara M; Noveral, Jocelyne

    2007-01-01

    This investigative laboratory exercise uses the different relations between ambient temperature and metabolic rate in endotherms and ectotherms as a core concept to answer the following question: What thermoregulatory mode is employed by chicken embryos? Emphasis is placed on the physiological concepts that can be taught with this exercise,…

  11. The efficacy of unsupervised home-based exercise regimens in comparison to supervised laboratory-based exercise training upon cardio-respiratory health facets.

    Science.gov (United States)

    Blackwell, James; Atherton, Philip J; Smith, Kenneth; Doleman, Brett; Williams, John P; Lund, Jonathan N; Phillips, Bethan E

    2017-09-01

    Supervised high-intensity interval training (HIIT) can rapidly improve cardiorespiratory fitness (CRF). However, the effectiveness of time-efficient unsupervised home-based interventions is unknown. Eighteen volunteers completed either: laboratory-HIIT (L-HIIT); home-HIIT (H-HIIT) or home-isometric hand-grip training (H-IHGT). CRF improved significantly in L-HIIT and H-HIIT groups, with blood pressure improvements in the H-IHGT group only. H-HIIT offers a practical, time-efficient exercise mode to improve CRF, away from the laboratory environment. H-IHGT potentially provides a viable alternative to modify blood pressure in those unable to participate in whole-body exercise. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  12. Teaching baroreflex physiology to medical students: a comparison of quiz-based and conventional teaching strategies in a laboratory exercise.

    Science.gov (United States)

    Berg, Ronan M G; Plovsing, Ronni R; Damgaard, Morten

    2012-06-01

    Quiz-based and collaborative teaching strategies have previously been found to be efficient for the improving meaningful learning of physiology during lectures. These approaches have, however, not been investigated during laboratory exercises. In the present study, we compared the impact of solving quizzes individually and in groups with conventional teaching on the immediate learning during a laboratory exercise. We implemented two quizzes in a mandatory 4-h laboratory exercise on baroreflex physiology. A total of 155 second-year medical students were randomized to solve quizzes individually (intervention group I, n = 57), in groups of three to four students (intervention group II, n = 56), or not to perform any quizzes (control; intervention group III, n = 42). After the laboratory exercise, all students completed an individual test, which encompassed two recall questions, two intermediate questions, and two integrated questions. The integrated questions were of moderate and advanced difficulty, respectively. Finally, students completed an evaluation form. Intervention group I reached the highest total test scores and proved best at answering the integrated question of advanced difficulty. Moreover, there was an overall difference between groups for student evaluations of the quality of the teaching, which was highest for intervention group II. In conclusion, solving quizzes individually during a laboratory exercise may enhance learning, whereas solving quizzes in groups is associated with higher student satisfaction.

  13. Methods of Estimation the Reliability and Increasing the Informativeness of the Laboratory Results (Analysis of the Laboratory Case of Measurement the Indicators of Thyroid Function)

    OpenAIRE

    N A Kovyazina; N A Alhutova; N N Zybina; N M Kalinina

    2014-01-01

    The goal of the study was to demonstrate the multilevel laboratory quality management system and point at the methods of estimating the reliability and increasing the amount of information content of the laboratory results (on the example of the laboratory case). Results. The article examines the stages of laboratory quality management which has helped to estimate the reliability of the results of determining Free T3, Free T4 and TSH. The measurement results are presented by the expanded unce...

  14. Introducing Human Population Biology through an Easy Laboratory Exercise on Mitochondrial DNA

    Science.gov (United States)

    Pardinas, Antonio F.; Dopico, Eduardo; Roca, Agustin; Garcia-Vazquez, Eva; Lopez, Belen

    2010-01-01

    This article describes an easy and cheap laboratory exercise for students to discover their own mitochondrial haplogroup. Students use buccal swabs to obtain mucosa cells as noninvasive tissue samples, extract DNA, and with a simple polymerase chain reaction-restriction fragment length polymorphism analysis they can obtain DNA fragments of…

  15. A Laboratory Exercise Using a Physical Model for Demonstrating Countercurrent Heat Exchange

    Science.gov (United States)

    Loudon, Catherine; Davis-Berg, Elizabeth C.; Botz, Jason T.

    2012-01-01

    A physical model was used in a laboratory exercise to teach students about countercurrent exchange mechanisms. Countercurrent exchange is the transport of heat or chemicals between fluids moving in opposite directions separated by a permeable barrier (such as blood within adjacent blood vessels flowing in opposite directions). Greater exchange of…

  16. A Laboratory Exercise to Determine Human ABO Blood Type by Noninvasive Methods

    Science.gov (United States)

    Martin, Michael P.; Detzel, Stephen M.

    2008-01-01

    Analysis of single-nucleotide polymorphisms and their association with diseases and nondisease phenotypes is of growing importance in human biology studies. In this laboratory exercise, students determine the genetic basis for their ABO blood type; however, no blood is drawn. Students isolate genomic DNA from buccal mucosa cells that are present…

  17. Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review

    NARCIS (Netherlands)

    Ratter, Julia; Radlinger, Lorenz; Lucas, Cees

    2014-01-01

    Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Systematic review of studies of the psychometric properties of exercise tests. People older than 18 years with chronic pain, fibromyalgia and chronic fatigue

  18. Results Assessment of Intercomparison Exercise CSN/CIEMAT-2010 among Spanish National Laboratories of Environmental Radioactivity (Diet Ashes)

    International Nuclear Information System (INIS)

    Gasco, C.; Trinidad, J. A.; Llaurado, M.; Suarez, J. A.

    2012-01-01

    This report describes the results assessment of the intercomparison exercise among environmental radioactivity laboratories, organised by Spanish Regulatory Institution (CSN) and prepared and evaluated by UAB and CIEMAT respectively. The exercise has been carried out following the international standards ISO-43 and ISO/IUPAC that provide a useful guide to perform proficiency tests and inter-laboratories comparisons. The selected matrix for this year (2010) was a diet ash obtained from the ashing of a whole fresh diet (breakfast, lunch and dinner), that was enriched with artificial radionuclides (Cs-137, Co-60,Fe-55,Ni-63,Sr-90,Am-241,Pu-238,Pu-239,240 y C-14) and contained natural radionuclides (U-234, U-238, U-natural Th-230, Th-234, Ra-226, Ra-228, Pb-210, Pb-212, Pb-214, Bi-214, Ac-228, Tl-208, K-40) at environmental level of activity concentration. The z-score test was applied to determine how much the laboratories differ from the reference value. The reference value for this exercise was the median of the results from the different laboratories and their standard deviations to achieve a more complete and objective study of the laboratories performance. The participant laboratories have demonstrated a satisfactory quality level for measuring the natural and artificial radionuclides content in this matrix. The reference values obtained through the medians show a negative bias for Pb-210 and Th-234 when comparing to the given values of external qualified laboratories from ENEA and IRSN and positive one for K-40. (Author)

  19. The Power of Exercise and the Exercise of Power: The Harvard Fatigue Laboratory, Distance Running, and the Disappearance of Work, 1919-1947.

    Science.gov (United States)

    Scheffler, Robin Wolfe

    2015-08-01

    In the early twentieth century, fatigue research marked an area of conflicting scientific, industrial, and cultural understandings of working bodies. These different understandings of the working body marked a key site of political conflict during the growth of industrial capitalism. Many fatigue researchers understood fatigue to be a physiological fact and allied themselves with Progressive-era reformers in urging industrial regulation. Opposed to these researchers were advocates of Taylorism and scientific management, who held that fatigue was a mental event and that productivity could be perpetually increased through managerial efficiency. Histories of this conflict typically cease with the end of the First World War, when it is assumed that industrial fatigue research withered away. This article extends the history of fatigue research through examining the activities of the Harvard Fatigue Laboratory in the 1920s and 1930s. The Laboratory developed sophisticated biochemical techniques to study the blood of exercising individuals. In particular, it found that exercising individuals could attain a biochemically "steady state," or equilibrium, and extrapolated from this to assert that fatigue was psychological, not physiological, in nature. In contrast to Progressive-era research, the Laboratory reached this conclusion through laboratory examination, not of industrial workers, but of Laboratory staff members and champion marathon runners. The translation of laboratory research to industrial settings, and the eventual erasure of physiological fatigue from discussions of labor, was a complex function of institutional settings, scientific innovation, and the cultural meanings of work and sport.

  20. Exercise for laboratory comparison of calibration coefficient in {sup 137}Cs beam, radiation protection - 2013/2014; Exercicio de comparacao laboratorial do coeficiente de calibracao em feixe de Cesio-137, radioprotecao - 2013/2014

    Energy Technology Data Exchange (ETDEWEB)

    Cabral, T.S. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Potiens, M.P.A., E-mail: tschirn@ird.gov.br [Instituto de Pesquisas Energeticas e Nucleres (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Soares, C.M.A. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Silveira, R.R. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Khoury, H. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Fernandes, E. [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Laboratorio de Ciencias Radiologicas; Cardoso, W.F. [Eletrobras Termonuclear S.A. (Eletronuclear), Rio de Janeiro, RJ (Brazil); Borges, J.C. [MRA Comercio de Instrumentos Eletronicos Ltda., Ribeirao Preto, SP (Brazil)

    2015-07-01

    This work deals with the preliminary results of the second exercise of comparing the radiation monitors calibration laboratories in Brazil. The exercise involved eight laboratories and the measured quantity is the air kerma in a beam of {sup 137}Cs for radioprotection. The exercise was conducted by the LNMRI/IRD, in a star shaped arrangement from October 2013 to July 2015. The largest deviation was 2% of the calibration coefficient that is acceptable for applications in radioprotection. (author)

  1. IAEA intercomparison exercises of thyroid measurement: performance of Latin American and Caribbean laboratories

    International Nuclear Information System (INIS)

    Dantas, B.M.; Dantas, A.L.A.; Cruz-Suarez, R.

    2016-01-01

    131 I is widely used in Latin America and Caribbean Region in the field of nuclear medicine and has been recognised as one of the main sources of potential intake of radionuclides by the staff. The In Vivo Monitoring laboratory of the Institute for Radiation Protection and Dosimetry (IRD-CNEN-Brazil) organised three intercomparison exercises (2005, 2009 and 2013) in the scope of IAEA technical cooperation projects RLA9049 and RLA9066 aimed to disseminate and harmonise the technique for measuring 131 I in the human thyroid. The number of participants in Latin America increased from 9 to 20 institutions from 7 and 13 countries, respectively, over the last 10 y. The participants have improved significantly their ability on the in vivo measurement technique. In the 2013 round all laboratories which reported results presented performances in an acceptable range according to the ISO criteria indicating the benefit of such exercises in the region. (authors)

  2. Real-time laboratory exercises to test contingency plans for classical swine fever: experiences from two national laboratories.

    Science.gov (United States)

    Koenen, F; Uttenthal, A; Meindl-Böhmer, A

    2007-12-01

    In order to adequately and efficiently handle outbreaks of contagious diseases such as classical swine fever (CSF), foot and mouth disease or highly pathogenic avian influenza, competent authorities and the laboratories involved have to be well prepared and must be in possession of functioning contingency plans. These plans should ensure that in the event of an outbreak access to facilities, equipment, resources, trained personnel, and all other facilities needed for the rapid and efficient eradication of the outbreak is guaranteed, and that the procedures to follow are well rehearsed. It is essential that these plans are established during 'peace-time' and are reviewed regularly. This paper provides suggestions on how to perform laboratory exercises to test preparedness and describes the experiences of two national reference laboratories for CSF. The major lesson learnt was the importance of a well-documented laboratory contingency plan. The major pitfalls encountered were shortage of space, difficulties in guaranteeing biosecurity and sufficient supplies of sterile equipment and consumables. The need for a standardised laboratory information management system, that is used by all those involved in order to reduce the administrative load, is also discussed.

  3. Exercise azm-e-nau-3, the laboratory perspective

    International Nuclear Information System (INIS)

    Sharif, T.B.

    2013-01-01

    Objective: To describe the adequacy of laboratory equipment and human resource for dealing one thousand war wounded casualties. Study Design: A descriptive study. Place and Duration of Study: Combined Military Hospital Bahawalpur, from 10th April to 19th April 2010. Material and Methods: Two teams each headed by a qualified pathologist worked round the clock in twelve hour shift dealing with the samples of war wounded (WW) casualties along with routine indoor /outdoor workload. Receipt of samples, analysis, reporting, record keeping, blood donation and transfusion were according to the protocol following turn around time (TAT). Results: A total of 5487 analyses were done in a period of ten days. All range of investigations were requested but blood complete picture (CP) constituted the maximum (33.9%) followed by hepatitis screening (22.7%) and biochemical profiles (17%). Other investigations were in connection with the preparation of the patients for surgery. A total of 101 pints of blood were issued during the course of exercise, with maximum on the 16th April 2010 constituting 20.7% of total. Maximum number of pints of blood issued to any single WW casualty was five amounting to 4.9% of the total. Conclusion: CMH Bahawalpur pathology laboratory successfully managed the load of 1000 WW casualties by providing prompt laboratory support for treatment, by timely delivery of requisite results of investigations and blood transfusion. (author)

  4. The Trojan Lifetime Champions Health Survey: Development, Validity, and Reliability

    Science.gov (United States)

    Sorenson, Shawn C.; Romano, Russell; Scholefield, Robin M.; Schroeder, E. Todd; Azen, Stanley P.; Salem, George J.

    2015-01-01

    Context Self-report questionnaires are an important method of evaluating lifespan health, exercise, and health-related quality of life (HRQL) outcomes among elite, competitive athletes. Few instruments, however, have undergone formal characterization of their psychometric properties within this population. Objective To evaluate the validity and reliability of a novel health and exercise questionnaire, the Trojan Lifetime Champions (TLC) Health Survey. Design Descriptive laboratory study. Setting A large National Collegiate Athletic Association Division I university. Patients or Other Participants A total of 63 university alumni (age range, 24 to 84 years), including former varsity collegiate athletes and a control group of nonathletes. Intervention(s) Participants completed the TLC Health Survey twice at a mean interval of 23 days with randomization to the paper or electronic version of the instrument. Main Outcome Measure(s) Content validity, feasibility of administration, test-retest reliability, parallel-form reliability between paper and electronic forms, and estimates of systematic and typical error versus differences of clinical interest were assessed across a broad range of health, exercise, and HRQL measures. Results Correlation coefficients, including intraclass correlation coefficients (ICCs) for continuous variables and κ agreement statistics for ordinal variables, for test-retest reliability averaged 0.86, 0.90, 0.80, and 0.74 for HRQL, lifetime health, recent health, and exercise variables, respectively. Correlation coefficients, again ICCs and κ, for parallel-form reliability (ie, equivalence) between paper and electronic versions averaged 0.90, 0.85, 0.85, and 0.81 for HRQL, lifetime health, recent health, and exercise variables, respectively. Typical measurement error was less than the a priori thresholds of clinical interest, and we found minimal evidence of systematic test-retest error. We found strong evidence of content validity, convergent

  5. Test-retest reliability of barbell velocity during the free-weight bench-press exercise.

    Science.gov (United States)

    Stock, Matt S; Beck, Travis W; DeFreitas, Jason M; Dillon, Michael A

    2011-01-01

    The purpose of this study was to calculate test-retest reliability statistics for peak barbell velocity during the free-weight bench-press exercise for loads corresponding to 10-90% of the 1-repetition maximum (1RM). Twenty-one healthy, resistance-trained men (mean ± SD age = 23.5 ± 2.7 years; body mass = 90.5 ± 14.6 kg; 1RM bench press = 125.4 ± 18.4 kg) volunteered for this study. A minimum of 48 hours after a maximal strength testing and familiarization session, the subjects performed single repetitions of the free-weight bench-press exercise at each tenth percentile (10-90%) of the 1RM on 2 separate occasions. For each repetition, the subjects were instructed to press the barbell as rapidly as possible, and peak barbell velocity was measured with a Tendo Weightlifting Analyzer. The test-retest intraclass correlation coefficients (model 2,1) and corresponding standard errors of measurement (expressed as percentages of the mean barbell velocity values) were 0.717 (4.2%), 0.572 (5.0%), 0.805 (3.1%), 0.669 (4.7%), 0.790 (4.6%), 0.785 (4.8%), 0.811 (5.8%), 0.714 (10.3%), and 0.594 (12.6%) for the weights corresponding to 10-90% 1RM. There were no mean differences between the barbell velocity values from trials 1 and 2. These results indicated moderate to high test-retest reliability for barbell velocity from 10 to 70% 1RM but decreased consistency at 80 and 90% 1RM. When examining barbell velocity during the free-weight bench-press exercise, greater measurement error must be overcome at 80 and 90% 1RM to be confident that an observed change is meaningful.

  6. Reliability of laser Doppler, near-infrared spectroscopy and Doppler ultrasound for peripheral blood flow measurements during and after exercise in the heat.

    Science.gov (United States)

    Choo, Hui C; Nosaka, Kazunori; Peiffer, Jeremiah J; Ihsan, Mohammed; Yeo, Chow C; Abbiss, Chris R

    2017-09-01

    This study examined the test-retest reliability of near-infrared spectroscopy (NIRS), laser Doppler flowmetry (LDF) and Doppler ultrasound to assess exercise-induced haemodynamics. Nine men completed two identical trials consisting of 25-min submaximal cycling at first ventilatory threshold followed by repeated 30-s bouts of high-intensity (90% of peak power) cycling in 32.8 ± 0.4°C and 32 ± 5% relative humidity (RH). NIRS (tissue oxygenation index [TOI] and total haemoglobin [tHb]) and LDF (perfusion units [PU]) signals were monitored continuously during exercise, and leg blood flow was assessed by Doppler ultrasound at baseline and after exercise. Cutaneous vascular conductance (CVC; PU/mean arterial pressure (MAP)) was expressed as the percentage change from baseline (%CVC BL ). Coefficients of variation (CVs) as indicators of absolute reliability were 18.7-28.4%, 20.2-33.1%, 42.5-59.8%, 7.8-12.4% and 22.2-30.3% for PU, CVC, %CVC BL , TOI and tHb, respectively. CVs for these variables improved as exercise continued beyond 10 min. CVs for baseline and post-exercise leg blood flow were 17.8% and 10.5%, respectively. CVs for PU, tHb (r 2  = 0.062) and TOI (r 2  = 0.002) were not correlated (P > 0.05). Most variables demonstrated CVs lower than the expected changes (35%) induced by training or heat stress; however, minimum of 10 min exercise is recommended for more reliable measurements.

  7. Test-retest reliabilty of exercise-induced hypoalgesia after aerobic exercise

    DEFF Research Database (Denmark)

    Vaegter, Henrik Bjarke; Dørge, Daniel Bandholtz; Schmidt, Kristian Sonne

    2018-01-01

    Objective: Exercise increases pressure pain thresholds (PPTs) in exercising and nonexercising muscles, known as exercise-induced hypoalgesia (EIH). No studies have investigated the test-retest reliability of change in PPTs after aerobic exercise. Primary objectives were to compare the effect...

  8. Exercise of Intercomparison on characterization of graphite irradiated: CW-RRT

    International Nuclear Information System (INIS)

    Pina, G.; Rodriguez, M.; Lara, E.; Magro, E.

    2014-01-01

    Knowledge of inventory of irradiated graphite (i-graphite) of nuclear reactors is a critical parameter for the proper management of waste. For this reason it is of paramount importance have access to reliable analytical methodologies to provide accurate results through radiochemical procedures specifics. La reliability of the result depends on both its precision and the accuracy obtained. this requires specific tasks compared to other methods, such as the extent of an array reference or conducting intercomparison exercises between laboratories. (Author)

  9. Results of the Interlaboratory Exercise CSN/CIEMAT-100 Among Environmental Radioactivity Laboratories (Soil); Resultados del Ejercicio Interlaboratorios de Radiactividad Ambiental CSN/CIEMAT-00 (Suelo)

    Energy Technology Data Exchange (ETDEWEB)

    Romero Gonzalez, M. L.

    2002-07-01

    The document describes the outcome of the CSN/CIEMAT-00 interlaboratory test comparison among environmental radioactivity laboratories. the exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC Harmonized Protocol for the proficiency testing of analytical laboratories. the test sample was a soil containing environmental levels of K-40, Ra-226, Ac-228, Sr-90, Cs-137, Cs-134, Pu (239-240) y Am-241. the Universidad Autonoma de Barcelona prepared the material and reported adequate statistical studies of homogeneity. The results of the exercise were computed for 30 participating laboratories, and their analytical performance was assessed using the u-score approach. A raised percentage of satisfactory laboratory performance has been obtained for all the analysis, being the best performance in gamma measurements. The exercise has drawn that several laboratories have difficulties in the evaluation of combined uncertainty, mainly in analysis involving radiochemical steps. The study has shown an homogeneous inter-laboratory behaviour, and the improvement achieved through subsequent exercises in the quality of the data they are producing. (Author) 10 refs.

  10. Spill exercise 1980: an LLNL emergency training exercise

    International Nuclear Information System (INIS)

    Morse, J.L.; Gibson, T.A.; Vance, W.F.

    1981-01-01

    An emergency training exercise at Lawrence Livermore National Laboratory (LLNL) demonstrated that off-hours emergency personnel can respond promptly and effecively to an emergency situation involving radiation, hazardous chemicals, and injured persons. The exercise simulated an explosion in a chemistry laboratory and a subsequent toxic-gas release

  11. Exercise 5+6 - Introduction to Control and Lab Exercises

    DEFF Research Database (Denmark)

    Kramer, Morten Mejlhede

    2015-01-01

    Exercises for the 2nd AAU and ECN EWTEC affiliated PhD course. The laboratory exercises are including both numerical and experimental work. A simulink model is provided to make realtime control on the laboratory setups. The groups are welcome to modify the program during the exercises. The groups...... are expected to make their own programs for numerical simulations on the device. Hydrodynamic parameters found using WAMIT are provided, but the groups are of course welcome to calculate their own parameters (e.g. using Nemoh). Exercise 5: Simple control and regular wave Exercise 6: Advanced control...

  12. Reliability of an incremental exercise test to evaluate acute blood lactate, heart rate and body temperature responses in Labrador retrievers.

    Science.gov (United States)

    Ferasin, Luca; Marcora, Samuele

    2009-10-01

    Thirteen healthy Labrador retrievers underwent a 5-stage incremental treadmill exercise test to assess its reliability. Blood lactate (BL), heart rate (HR), and body temperature (BT) were measured at rest, after each stage of exercise, and after a 20-min recovery. Reproducibility was assessed by repeating the test after 7 days. Two-way MANOVAs revealed significant differences between consecutive stages, and between values at rest and after recovery. There was also a significant reduction in physiological strain between the first and second trial (learning effect). Test reliability expressed as typical error (BL = 0.22 mmol/l, HR = 9.81 bpm, BT = 0.22 degrees C), coefficient of variation (BL = 19.3%, HR = 7.9% and BT = 0.6%) and test-retest correlation (BL = 0.89, HR = 0.96, BT = 0.95) was good. Results support test reproducibility although the learning effect needs to be controlled when investigating the exercise-related problems commonly observed in this breed.

  13. Problem-Based Learning and Creative Instructional Approaches for Laboratory Exercises in Introductory Crop Science

    Science.gov (United States)

    Teplitski, Max; McMahon, Margaret J.

    2006-01-01

    The implementation of problem-based learning (PBL) and other inquiry-driven educational techniques is often resisted by both faculty and students, who may not be comfortable with this learning/instructional style. We present here a hybrid approach, which combines elements of expository education with inquiry-driven laboratory exercises and…

  14. Validity and Reliability of the PUSH Wearable Device to Measure Movement Velocity During the Back Squat Exercise.

    Science.gov (United States)

    Balsalobre-Fernández, Carlos; Kuzdub, Matt; Poveda-Ortiz, Pedro; Campo-Vecino, Juan Del

    2016-07-01

    Balsalobre-Fernández, C, Kuzdub, M, Poveda-Ortiz, P, and Campo-Vecino, Jd. Validity and reliability of the PUSH wearable device to measure movement velocity during the back squat exercise. J Strength Cond Res 30(7): 1968-1974, 2016-The purpose of this study was to analyze the validity and reliability of a wearable device to measure movement velocity during the back squat exercise. To do this, 10 recreationally active healthy men (age = 23.4 ± 5.2 years; back squat 1 repetition maximum [1RM] = 83 ± 8.2 kg) performed 3 repetitions of the back squat exercise with 5 different loads ranging from 25 to 85% 1RM on a Smith Machine. Movement velocity for each of the total 150 repetitions was simultaneously recorded using the T-Force linear transducer (LT) and the PUSH wearable band. Results showed a high correlation between the LT and the wearable device mean (r = 0.85; standard error of estimate [SEE] = 0.08 m·s) and peak velocity (r = 0.91, SEE = 0.1 m·s). Moreover, there was a very high agreement between these 2 devices for the measurement of mean (intraclass correlation coefficient [ICC] = 0.907) and peak velocity (ICC = 0.944), although a systematic bias between devices was observed (PUSH peak velocity being -0.07 ± 0.1 m·s lower, p ≤ 0.05). When measuring the 3 repetitions with each load, both devices displayed almost equal reliability (Test-retest reliability: LT [r = 0.98], PUSH [r = 0.956]; ICC: LT [ICC = 0.989], PUSH [ICC = 0.981]; coefficient of variation [CV]: LT [CV = 4.2%], PUSH [CV = 5.0%]). Finally, individual load-velocity relationships measured with both the LT (R = 0.96) and the PUSH wearable device (R = 0.94) showed similar, very high coefficients of determination. In conclusion, these results support the use of an affordable wearable device to track velocity during back squat training. Wearable devices, such as the one in this study, could have valuable practical applications for strength and conditioning coaches.

  15. Witnessing Evolution First Hand: A K-12 Laboratory Exercise in Genetics & Evolution Using "Drosophila"

    Science.gov (United States)

    Heil, Caiti S. S.; Manzano-Winkler, Brenda; Hunter, Mika J.; Noor, Juliet K. F.; Noor, Mohamed A. F.

    2013-01-01

    We present a laboratory exercise that leverages student interest in genetics to observe and understand evolution by natural selection. Students begin with white-eyed fruit fly populations, to which they introduce a single advantageous variant (one male with red eyes). The superior health and vision associated with having the red-eye-color allele…

  16. [The analytical reliability of clinical laboratory information and role of the standards in its support].

    Science.gov (United States)

    Men'shikov, V V

    2012-12-01

    The article deals with the factors impacting the reliability of clinical laboratory information. The differences of qualities of laboratory analysis tools produced by various manufacturers are discussed. These characteristics are the causes of discrepancy of the results of laboratory analyses of the same analite. The role of the reference system in supporting the comparability of laboratory analysis results is demonstrated. The project of national standard is presented to regulate the requirements to standards and calibrators for analysis of qualitative and non-metrical characteristics of components of biomaterials.

  17. [The external evaluation of study quality: the role in maintaining the reliability of laboratory information].

    Science.gov (United States)

    Men'shikov, V V

    2013-08-01

    The external evaluation of quality of clinical laboratory examinations was gradually introduced in USSR medical laboratories since 1970s. In Russia, in the middle of 1990 a unified all-national system of external evaluation quality was organized known as the Federal center of external evaluation of quality at the basis of laboratory of the state research center of preventive medicine. The main positions of policy in this area were neatly formulated in the guidance documents of ministry of Health. Nowadays, the center of external evaluation of quality proposes 100 and more types of control studies and permanently extends their specter starting from interests of different disciplines of clinical medicine. The consistent participation of laboratories in the cycles of external evaluation of quality intrinsically promotes improvement of indicators of properness and precision of analysis results and increases reliability of laboratory information. However, a significant percentage of laboratories does not participate at all in external evaluation of quality or takes part in control process irregularly and in limited number of tests. The managers of a number of medical organizations disregard the application of the proposed possibilities to increase reliability of laboratory information and limit financing of studies in the field of quality control. The article proposes to adopt the national standard on the basis of ISO 17043 "Evaluation of compliance. The common requirements of professional competence testing".

  18. Importance of Intercomparison Exercises in Assessment of Internal Exposure by Whole-Body Counter

    International Nuclear Information System (INIS)

    Andrasi, A.

    2001-01-01

    Full text: Basic requirement for any kind of measurement is to check and prove the reliability and correctness of the measured results. Quality assurance programmes require several activities among which the participation in intercomparison exercises plays an important role. Since the determination of radioactive materials in the human body by whole-body counting technique implies many sources of uncertainties the reliability of calibration data and consequently the measured results have to be checked by participation in intercomparison quality control programmes. In these programmes mostly different kinds of phantoms simulating the human body are circulated among the participating laboratories, however sometimes contaminated persons are also subjects of intercomparison measurements. There are guidelines in several countries laid down concerning the requirements of whole-body counter measurements where the performance criteria for the relative bias, precision and minimum detectable amounts are formulated. These quantities are mostly the subject of intercomparison programmes. The whole body counter laboratory of the KFKI Atomic Energy Research Institute participated in intercomparison exercises several times in the last few years. The lessons learned during these activities helped in checking the capabilities of applied methods and measuring geometry as well as contributed in improving the accuracy of the measured results. A short overview on the previous international intercomparison exercises their main characteristics the results obtained and conclusions drawn are discussed in the paper with special attention to those in which also our laboratory participated. (author)

  19. Interlaboratory test comparison among Environmental Radioactivity Laboratories using the ISO/IUPAC/AOAC Protocol

    International Nuclear Information System (INIS)

    Romero, L.; Ramos, L.; Salas, R.

    1998-01-01

    World-wide acceptance of results from radiochemical analyses requires reliable, traceable and comparable measurements to SI units, particularly when data sets generated by laboratories are to contribute to evaluation of data from environmental pollution research and monitoring programmes. The Spanish Nuclear Safety Council (CSN) organizes in collaboration with CIEMAT periodical interlaboratory test comparisons for environmental radioactivity laboratories aiming to provide them with the necessary means to asses the quality of their results. This paper presents data from the most recent exercise which, for the first time, was evaluated following the procedure recommended in the ISO/IUPAC/AOAC Harmonized Protocol for the proficiency testing of analytical laboratories (1). The test sample was a Reference Material provided by the IAEA-AQCS, a lake sediment containing the following radionuclides: k-40, Ra-226, Ac-228, Cs-137, Sr-90, Pu-(239+240). The results of the proficiency test were computed for the 28 participating laboratories using the z-score approach, the evaluation of the exercises is presented in the paper. The use of a z-score classification has demonstrated to provide laboratories with a more objective means of assessing and demonstrating the reliability of the data they are producing. Analytical proficiency of the participating laboratories has been found to be satisfactory in 57 to 100 percent of cases. (1)- The International harmonized protocol for the proficiency testing of (chemical) analytical laboratories. Pure and Appl. Chem. Vol. 65, n 9, pp. 2123-2144, 1993 IUPAC. GB (Author) 3 refs

  20. The interrater reliability of rating non-exercise activity of inpatients with eating disorders using a visual analogue scale.

    Science.gov (United States)

    Mazloum, A; Johnston, M; Lundrigan, M; Birmingham, C L

    2008-12-01

    Non-exercise activity thermogenesis (NEAT) is the energy expended by body movement, other than sleeping, eating or sports-like activities. The obese have been reported to have a lower NEAT (walking, standing, and fidgeting) than controls. We hypothesize that an elevated NEAT could explain why some patients with anorexia nervosa are resistant to weight gain. To evaluate the interrater reliability of a rating of non-exercise activity of inpatients with eating disorders (ED) using a visual analogue scale (VAS). Health care providers were asked to rate the non-exercise activity of inpatients by marking a VAS. Eight patients were individually rated by 10 clinicians. Results were analyzed using the intraclass correlation coefficient (ICC) and Cohen's multi-rater kappa statistic (kappa). The ICC(3,k) was 0.257 (pexercise activity and physiological measurements should be used.

  1. The histopathologic reliability of tissue taken from cadavers within the gross anatomy laboratory.

    Science.gov (United States)

    Rae, Guenevere; Newman, William P; McGoey, Robin; Donthamsetty, Supriya; Karpinski, Aryn C; Green, Jeffrey

    2018-03-01

    The purpose of this study was to examine the histopathologic reliability of embalmed cadaveric tissue taken from the gross anatomy laboratory. Tissue samples from hearts, livers, lungs, and kidneys were collected after the medical students' dissection course was completed. All of the cadavers were embalmed in a formalin-based fixative solution. The tissue was processed, embedded in paraffin, sectioned at six micrometers, and stained with H&E. The microscope slides were evaluated by a board certified pathologist to determine whether the cellular components of the tissues were preserved at a high enough quality to allow for histopathologic diagnosis. There was a statistically significant relationship between ratings and organ groups. Across all organs, there was a smaller proportion of "poor" ratings. The lung group had the highest percentage of "poor" ratings (23.1%). The heart group had the least "poor" ratings (0.0%). The largest percentage of "satisfactory" ratings were in the lung group (52.8%), and the heart group contained the highest percentage of "good" ratings (58.5%) The lung group had the lowest percentage of "good" ratings (24.2%). These results indicate that heart tissue is more reliable than lung, kidney, or liver tissue when utilizing tissue from the gross anatomy laboratory for research and/or educational purposes. This information advises educators and researchers about the quality and histopathologic reliability of tissue samples obtained from the gross anatomy laboratory. Anat Sci Educ 11: 207-214. © 2017 American Association of Anatomists. © 2017 American Association of Anatomists.

  2. Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review

    OpenAIRE

    Julia Ratter; Lorenz Radlinger; Cees Lucas

    2014-01-01

    Question: Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Design: Systematic review of studies of the psychometric properties of exercise tests. Participants: People older than 18 years with chronic pain, fibromyalgia and chronic fatigue disorders. Intervention: Studies of the measurement properties of tests of physical capacity in people with chronic pain, fibromyalgia or chronic fatigue disorders were ...

  3. Why Is That Dog Paralyzed? A Problem-Based Case & Laboratory Exercise about Neuromuscular Transmission

    Science.gov (United States)

    Milanick, Mark; Graham, Kerri; Wessel, Melissa

    2013-01-01

    Students are provided with a mystery concerning dogs that are paralyzed. This motivates a laboratory exercise to measure parameters from the dog's "blood" to determine whether the paralysis is due to pesticide poisoning or an autoimmune attack on nerve myelin. Most of the materials are available from the grocery store. The real-world nature of the…

  4. Reliability research on nuclear I and C system at KAIST NIC laboratory

    International Nuclear Information System (INIS)

    Seong, Poong-Hyun

    1996-01-01

    As the use of computer systems becomes popular in nuclear industry, reliability assurance of digitized nuclear instrumentation and control systems is becoming one of hot issues. Some issues on this are S/W verification and validation, reliability estimation of digital systems, development strategy of high integrity knowledge base for expert systems, and so on. In order to address these issues, the Nuclear Instrumentation and Control (NIC) laboratory at KAIST is conducting some research projects. This paper describes some highlights of these research activities. The final goal of these research activities is to develop some useful methodologies and tools for development of dependable digital nuclear instrument and control systems. (author)

  5. Astronomy Laboratory Exercise on Olbers’ Paradox and the Age of the Universe

    Science.gov (United States)

    Glazer, Kelsey Samantha; Edwards, Charlotte; Overduin, James; Storrs, Alex

    2018-01-01

    We describe the development of a new laboratory exercise for undergraduate introductory astronomy courses. Students begin by estimating the intensity of the extragalactic background light using a simple Newtonian cosmological model that agrees with recent measurements to within a factor of two. They then use the 0.5m Towson University telescope to image a dark patch of sky such as the Hubble Deep Field near or during new Moon, and compare the intensity actually observed with that predicted. This comparison leads to a new appreciation of foreground contributions such as light pollution, airglow, zodiacal light, starlight and others. Students pick up important skills in uncertainty analysis and astronomical unit conversion. But the most valuable aspect of the exercise in our view is that it enables students to draw a direct connection between the evidence of their own eyes and the age of the Universe.

  6. Particle in a Disk: A Spectroscopic and Computational Laboratory Exercise Studying the Polycyclic Aromatic Hydrocarbon Corannulene

    Science.gov (United States)

    Frey, E. Ramsey; Sygula, Andrzej; Hammer, Nathan I.

    2014-01-01

    This laboratory exercise introduces undergraduate chemistry majors to the spectroscopic and theoretical study of the polycyclic aromatic hydrocarbon (PAH), corannulene. Students explore the spectroscopic properties of corannulene using UV-vis and Raman vibrational spectroscopies. They compare their experimental results to simulated vibrational…

  7. After Action Report: Idaho National Laboratory Annual Exercise June 10, 2015

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, Vernon Scott [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-07-01

    On June 10, 2015, Idaho National Laboratory (INL), in coordination with the State of Idaho, local jurisdictions, Department of Energy Idaho Operations Office (DOE-ID), and DOE Headquarters (DOE HQ), conducted the annual emergency exercise to demonstrate the ability to implement the requirements of DOE O 151.1C, “Comprehensive Emergency Management System.” The INL contractor, Battelle Energy Alliance, LLC (BEA), in coordination with other INL contractors, conducted operations and demonstrated appropriate response measures to mitigate an event and protect the health and safety of personnel, the environment, and property. Offsite response organizations participated to demonstrate appropriate response measures.

  8. Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review

    Directory of Open Access Journals (Sweden)

    Julia Ratter

    2014-09-01

    [Ratter J, Radlinger L, Lucas C (2014 Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review. Journal of Physiotherapy 60: 144–150

  9. A Mixed Learning Approach to Integrating Digital Signal Processing Laboratory Exercises into a Non-Lab Junior Year DSP Course

    Science.gov (United States)

    McPheron, Benjamin D.; Thangaraj, Charles V.; Thomas, Charles R.

    2017-01-01

    Laboratory courses can be difficult to fit into an engineering program at a liberal arts-focused university, which requires students to be exposed to appropriate breadth, as well as sufficient depth in their engineering education. One possible solution to this issue is to integrate laboratory exercises with lecture in a "studio" format,…

  10. Reliability Analysis of Traditional and Ballistic Bench Press Exercises at Different Loads

    Directory of Open Access Journals (Sweden)

    García-Ramos Amador

    2015-09-01

    Full Text Available The purpose of this study was to determine test–retest reliability for peak barbell velocity (Vpeak during the bench press (BP and bench press throw (BPT exercises for loads corresponding to 20–70% of one-repetition maximum (1RM. Thirty physically active collegiate men conducted four evaluations after a preliminary BP 1RM determination (1RM·bw-1 = 1.02 ± 0.16 kg·kg-1. In counterbalanced order, participants performed two sessions of the BP in one week and two sessions of the BPT in another week. Recovery time between sessions within the same week was 48 hours and recovery time between sessions of different weeks was 120 hours. On each day of evaluation the individual load-velocity relationship at each tenth percentile (20–70% of 1RM in a Smith machine for the BP or BPT was determined. Participants performed three attempts per load, but only the best repetition (highest Vpeak, registered by a linear position transducer, was analysed. The BPT resulted in a significantly lower coefficient of variation (CV for the whole load–velocity relationship, compared to the BP (2.48% vs. 3.22%; p = 0.040. Test–retest intraclass correlation coefficients (ICCs ranged from r = 0.94-0.85 for the BPT and r = 0.91-0.71 for the BP (p < 0.001. The reduction in the biological within-subject variation in BPT exercise could be promoted by the braking phase that obligatorily occurs during a BP executed with light or moderate loads. Therefore, we recommend the BPT exercise for a most accurate assessment of upper-body velocity.

  11. Stress analysis of R2 pressure vessel. Structural reliability benchmark exercise

    International Nuclear Information System (INIS)

    Vestergaard, N.

    1987-05-01

    The Structural Reliability Benchmark Exercise (SRBE) is sponsored by the EEC as part of the Reactor Safety Programme. The objectives of the SRBE are to evaluate and improve 1) inspection procedures, which use non-destructive methods to locate defects in pressure (reactor) vessels, as well as 2) analytical damage accumulation models, which predict the time to failure of vessels containing defects. In order to focus attention, an experimental presure vessel has been inspected, subjected fatigue loadings and subsequently analysed by several teams using methods of their choice. The present report contains the first part of the analytical damage accumulation analysis. The stress distributions in the welds of the experimental pressure vessel were determined. These stress distributions will be used to determine the driving forces of the damage accumulation models, which will be addressed in a future report. (author)

  12. The Histopathologic Reliability of Tissue Taken from Cadavers within the Gross Anatomy Laboratory

    Science.gov (United States)

    Rae, Guenevere; Newman, William P., III; McGoey, Robin; Donthamsetty, Supriya; Karpinski, Aryn C.; Green, Jeffrey

    2018-01-01

    The purpose of this study was to examine the histopathologic reliability of embalmed cadaveric tissue taken from the gross anatomy laboratory. Tissue samples from hearts, livers, lungs, and kidneys were collected after the medical students' dissection course was completed. All of the cadavers were embalmed in a formalin-based fixative solution.…

  13. ARGX-87: Accident Response Group Exercise, 1987: A Broken Arrow mini exercise

    International Nuclear Information System (INIS)

    Schuld, E.P.; Cruff, D.F.

    1987-07-01

    A Broken Arrow mini exercise dubbed ''Accident Response Group Exercise - 1987'' (ARGX-87) was conducted on June 1, 1987 at the Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratories, Livermore (SNLL). The exercise started at 0445 PDT with a call from the Department of Energy (DOE) - EOC in Washington, DC, to the Albuquerque Operations (AL - ) - EOC. AL, in turn, called the Laboratory off-hour emergency number (Fire Dispatcher), who called the Laboratory Emergency Duty Officer (LEDO). The LEDO then contacted the Accident Response Group (ARG) Senior Scientific Advisor. Calls were placed to assemble appropriate members of the ARG in the ALERT Center. No phone number for SNLL was available at the Albuquerque Operations EOC, so a controller injected a message to SNLL to get them involved in the exercise. The messages received at the Laboratory identified the Air Force line item weapon system involved in the accident and the accident location. As people arrived at the ALERT Center they began discussing the details of the accident. They also started working the deployment logistics and other issues. Travel arrangements for the HOT SPOT equipment and ARG personnel were made for immediate deployment to the accident site in North Dakota. The exercise was terminated at 0840 as planned. While certain procedural deficiencies were noted, the exercise was considered a valuable learning experience. The results and observations from this experience will be used to refine the operating procedures and the training program

  14. Different Cells Make Different Proteins: A Laboratory Exercise Illustrating Tissue-Specific Protein Expression in Animals

    Science.gov (United States)

    Ibarguren, Izaskun; Villamarín, Antonio

    2017-01-01

    All the cells of higher organisms have the same DNA but not the same proteins. Each type of specialised cell that forms a tissue has its own pattern of gene expression and, consequently, it contains a particular set of proteins that determine its function. Here, we describe a laboratory exercise addressed to undergraduate students that aims to…

  15. A Severe Weather Laboratory Exercise for an Introductory Weather and Climate Class Using Active Learning Techniques

    Science.gov (United States)

    Grundstein, Andrew; Durkee, Joshua; Frye, John; Andersen, Theresa; Lieberman, Jordan

    2011-01-01

    This paper describes a new severe weather laboratory exercise for an Introductory Weather and Climate class, appropriate for first and second year college students (including nonscience majors), that incorporates inquiry-based learning techniques. In the lab, students play the role of meteorologists making forecasts for severe weather. The…

  16. Cross-disciplinary thermoregulation and sweat analysis laboratory experiences for undergraduate Chemistry and Exercise Science students.

    Science.gov (United States)

    Mulligan, Gregory; Taylor, Nichole; Glen, Mary; Tomlin, Dona; Gaul, Catherine A

    2011-06-01

    Cross-disciplinary (CD) learning experiences benefit student understanding of concepts and curriculum by offering opportunities to explore topics from the perspectives of alternate fields of study. This report involves a qualitative evaluation of CD health sciences undergraduate laboratory experiences in which concepts and students from two distinct disciplines [chemistry (CHEM) and exercise physiology (EPHE)] combined to study exercise thermoregulation and sweat analysis. Twenty-eight senior BSc Kinesiology (EPHE) students and 42 senior BSc CHEM students participated as part of their mutually exclusive, respective courses. The effectiveness of this laboratory environment was evaluated qualitatively using written comments collected from all students as well as from formal focus groups conducted after the CD laboratory with a representative cohort from each class (n = 16 CHEM students and 9 EPHE students). An open coding strategy was used to analyze the data from written feedback and focus group transcripts. Coding topics were generated and used to develop five themes found to be consistent for both groups of students. These themes reflected the common student perceptions that the CD experience was valuable and that students enjoyed being able to apply academic concepts to practical situations as well as the opportunity to interact with students from another discipline of study. However, students also reported some challenges throughout this experience that stemmed from the combination of laboratory groups from different disciplines with limited modification to the design of the original, pre-CD, learning environments. The results indicate that this laboratory created an effective learning opportunity that fostered student interest and enthusiasm for learning. The findings also provide information that could inform subsequent design and implementation of similar CD experiences to enhance engagement of all students and improve instructor efficacy.

  17. Design of Cyberwar Laboratory Exercises to Implement Common Security Attacks against IEEE 802.11 Wireless Networks

    Directory of Open Access Journals (Sweden)

    Mina Malekzadeh

    2010-01-01

    Full Text Available In wireless network communications, radio waves travel through free space; hence, the information reaches any receiving point with appropriate radio receivers. This aspect makes the wireless networks vulnerable to various types of attacks. A true understanding of these attacks provides better ability to defend the network against the attacks, thus eliminating potential threats from the wireless systems. This work presents a series of cyberwar laboratory exercises that are designed for IEEE 802.11 wireless networks security courses. The exercises expose different aspects of violations in security such as confidentiality, privacy, availability, and integrity. The types of attacks include traffic analysis, rogue access point, MAC filtering, replay, man-in-the-middle, and denial of service attacks. For each exercise, the materials are presented as open-source tools along with descriptions of the respective methods, procedures, and penetration techniques.

  18. "Anisakis Simplex" Infection in Mackerel: A Reliable Laboratory Exercise to Demonstrate Important Principles in Parasitology to Undergraduates

    Science.gov (United States)

    Coombs, I.; Tatner, M.; Paterson, V.

    2013-01-01

    Practical laboratory work in parasitology can be very limited, due to the difficulty in maintaining multi-host parasite life cycles, especially for a large, once-yearly undergraduate laboratory class for life science students. The use of mackerel, "Scomber scombrus," bought from a local fishmonger, is an ideal model to investigate important…

  19. Results of the Interlaboratory Exercise CNS/CIEMAT-04 Among Environmental Radioactivity Laboratories (Aqueous Solution); Resultados del Ejercicio Interlaboratorios de Radiactividad Ambiental CSN/CIEMAT-04 (Solucion Acuosa)

    Energy Technology Data Exchange (ETDEWEB)

    Romero Gonzalez, M. L.; Barrera Izquierdo, M.

    2004-07-01

    The document describes the outcome of the CSN/CIEMAT-04 interlaboratory test comparison among environmental radioactivity laboratories. The exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC Harmonised Protocol for the proficiency testing of analytical laboratories. Following the issue of the European Community Drinking Water Directive 98/83/EC concerning the quality of water for human consumption, the last inter-comparison exercise was organised by using a water sample, in an attempt to evaluate the performance of the laboratories analysing the required radioactivity parameters (H-3, gross alpha and beta activity and residual beta). The sample (a synthetic drinking water), was prepared at the National Laboratory for Ionising Radiation's Standards (CIEMAT), and contained the following radionuclides ''241 Am, ''239+240 Pu, ''90Sr, ''137 Cs, ''3 H y ''40 K. The results of the exercise were computed for 38 participating laboratories, and their analytical performance was assessed using the z-score approach. Robust statistics of the participant's results was applied to obtain the median and standard deviation, including suspected outliers. The exercise has revealed and homogeneous behaviour of laboratories, being statistical parameters from the results close to the reference values. A raised percentage os satisfactory laboratory performance has been obtained for gross alpha, gross beta and residual beta: 85, 97 and 87% respectively. The study has shown that participant laboratories perform radioactive determinations in drinking water samples with satisfactory quality levels. (Author) 16 refs.

  20. Canadian inter-laboratory organically bound tritium (OBT) analysis exercise.

    Science.gov (United States)

    Kim, S B; Olfert, J; Baglan, N; St-Amant, N; Carter, B; Clark, I; Bucur, C

    2015-12-01

    Tritium emissions are one of the main concerns with regard to CANDU reactors and Canadian nuclear facilities. After the Fukushima accident, the Canadian Nuclear Regulatory Commission suggested that models used in risk assessment of Canadian nuclear facilities be firmly based on measured data. Procedures for measurement of tritium as HTO (tritiated water) are well established, but there are no standard methods and certified reference materials for measurement of organically bound tritium (OBT) in environmental samples. This paper describes and discusses an inter-laboratory comparison study in which OBT in three different dried environmental samples (fish, Swiss chard and potato) was measured to evaluate OBT analysis methods currently used by CANDU Owners Group (COG) members. The variations in the measured OBT activity concentrations between all laboratories were less than approximately 20%, with a total uncertainty between 11 and 17%. Based on the results using the dried samples, the current OBT analysis methods for combustion, distillation and counting are generally acceptable. However, a complete consensus OBT analysis methodology with respect to freeze-drying, rinsing, combustion, distillation and counting is required. Also, an exercise using low-level tritium samples (less than 100 Bq/L or 20 Bq/kg-fresh) would be useful in the near future to more fully evaluate the current OBT analysis methods. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  1. Factor structure and internal reliability of an exercise health belief model scale in a Mexican population

    Directory of Open Access Journals (Sweden)

    Oscar Armando Esparza-Del Villar

    2017-03-01

    Full Text Available Abstract Background Mexico is one of the countries with the highest rates of overweight and obesity around the world, with 68.8% of men and 73% of women reporting both. This is a public health problem since there are several health related consequences of not exercising, like having cardiovascular diseases or some types of cancers. All of these problems can be prevented by promoting exercise, so it is important to evaluate models of health behaviors to achieve this goal. Among several models the Health Belief Model is one of the most studied models to promote health related behaviors. This study validates the first exercise scale based on the Health Belief Model (HBM in Mexicans with the objective of studying and analyzing this model in Mexico. Methods Items for the scale called the Exercise Health Belief Model Scale (EHBMS were developed by a health research team, then the items were applied to a sample of 746 participants, male and female, from five cities in Mexico. The factor structure of the items was analyzed with an exploratory factor analysis and the internal reliability with Cronbach’s alpha. Results The exploratory factor analysis reported the expected factor structure based in the HBM. The KMO index (0.92 and the Barlett’s sphericity test (p < 0.01 indicated an adequate and normally distributed sample. Items had adequate factor loadings, ranging from 0.31 to 0.92, and the internal consistencies of the factors were also acceptable, with alpha values ranging from 0.67 to 0.91. Conclusions The EHBMS is a validated scale that can be used to measure exercise based on the HBM in Mexican populations.

  2. Evaluation of NDE Round-Robin Exercises Using the NRC Steam Generator Mockup at Argonne National Laboratory

    International Nuclear Information System (INIS)

    Muscara, Joseph; Kupperman, David S.; Bakhtiari, Sasab; Park, Jang-Yul; Shack, William J.

    2002-01-01

    This paper discusses round-robin exercises using the NRC steam generator (SG) mock-up at Argonne National Laboratory to assess inspection reliability. The purpose of the round robins was to assess the current reliability of SG tubing inservice inspection, determine the probability of detection (POD) as function of flaw size or severity, and assess the capability for sizing of flaws. For the round robin and subsequent evaluation completed in 2001, eleven teams participated. Bobbin and rotating coil mock-up data collected by qualified industry personnel were evaluated. The mock-up contains hundreds of cracks and simulations of artifacts such as corrosion deposits and tube support plates that make detection and characterization of cracks more difficult in operating steam generators than in most laboratory situations. An expert Task Group from industry, Argonne National Laboratory, and the NRC have reviewed the signals from the laboratory-grown cracks used in the mock-up to ensure that they provide reasonable simulations of those obtained in the field. The mock-up contains 400 tube openings. Each tube contains nine 22.2-mm (7/8-in.) diameter, 30.5-cm (1-ft) long, Alloy 600 test sections. The flaws are located in the tube sheet near the roll transition zone (RTZ), in the tube support plate (TSP), and in the free-span. The flaws are primarily intergranular stress corrosion cracks (axial and circumferential, ID and OD) though intergranular attack (IGA) wear and fatigue cracks are also present, as well as cracks in dents. In addition to the simulated tube sheet and TSP the mock-up has simulated sludge and magnetite deposits. A multiparameter eddy current algorithm, validated for mock-up flaws, provided a detailed isometric plot for every flaw and was used to establish the reference state of defects in the mock-up. The detection results for the 11 teams were used to develop POD curves as a function of maximum depth, voltage and the parameter m p, for the various types of

  3. Validity and reliability of a controlled pneumatic resistance exercise device.

    Science.gov (United States)

    Paulus, David C; Reynolds, Michael C; Schilling, Brian K

    2008-01-01

    During the concentric portion of the free-weight squat exercise, accelerating the mass from rest results in a fluctuation in ground reaction force. It is characterized by an initial period of force greater than the load while accelerating from rest followed by a period of force lower than the external load during negative acceleration. During the deceleration phase, less force is exerted and muscles are loaded sub-optimally. Thus, using a reduced inertia form of resistance such as pneumatics has the capability to minimize these inertial effects as well as control the force in real time to maximize the force exerted over the exercise cycle. To improve the system response of a preliminary design, a squat device was designed with a reduced mass barbell and two smaller pneumatic cylinders. The resistance was controlled by regulating cylinder pressure such that it is capable of adjusting force within a repetition to maximize force exerted during the lift. The resistance force production of the machine was statically validated with the input voltage and output force R2 =0.9997 for at four increments of the range of motion, and the intraclass correlation coefficient (ICC) between trials at the different heights equaled 0.999. The slew rate at three forces was 749.3 N/s +/- 252.3. Dynamic human subject testing showed the desired input force correlated with average and peak ground reaction force with R2 = 0.9981 and R2 = 0.9315, respectively. The ICC between desired force and average and peak ground reaction force was 0.963. Thus, the system is able to deliver constant levels of static and dynamic force with validity and reliability. Future work will be required to develop the control strategy required for real-time control, and performance testing is required to determine its efficacy.

  4. Models on reliability of non-destructive testing

    International Nuclear Information System (INIS)

    Simola, K.; Pulkkinen, U.

    1998-01-01

    The reliability of ultrasonic inspections has been studied in e.g. international PISC (Programme for the Inspection of Steel Components) exercises. These exercises have produced a large amount of information on the effect of various factors on the reliability of inspections. The information obtained from reliability experiments are used to model the dependency of flaw detection probability on various factors and to evaluate the performance of inspection equipment, including the sizing accuracy. The information from experiments is utilised in a most effective way when mathematical models are applied. Here, some statistical models for reliability of non-destructive tests are introduced. In order to demonstrate the use of inspection reliability models, they have been applied to the inspection results of intergranular stress corrosion cracking (IGSCC) type flaws in PISC III exercise (PISC 1995). The models are applied to both flaw detection frequency data of all inspection teams and to flaw sizing data of one participating team. (author)

  5. A Laboratory Exercise to Illustrate Increased Salivary Cortisol in Response to Three Stressful Conditions Using Competitive ELISA

    Science.gov (United States)

    Haussmann, Mark F.; Vleck, Carol M; Farrar, Eugenia S.

    2007-01-01

    Perceived stress activates the hypothalamus-pituitary-adrenal axis, resulting in the release of glucocorticoids into the systemic circulation. Glucocorticoids cause the elevation of blood glucose, providing the necessary energy for the organism to cope with stress. Here, we outline a laboratory exercise that uses a competitive ELISA kit to…

  6. Reassigning the Structures of Natural Products Using NMR Chemical Shifts Computed with Quantum Mechanics: A Laboratory Exercise

    Science.gov (United States)

    Palazzo, Teresa A.; Truong, Tiana T.; Wong, Shirley M. T.; Mack, Emma T.; Lodewyk, Michael W.; Harrison, Jason G.; Gamage, R. Alan; Siegel, Justin B.; Kurth, Mark J.; Tantillo, Dean J.

    2015-01-01

    An applied computational chemistry laboratory exercise is described in which students use modern quantum chemical calculations of chemical shifts to assign the structure of a recently isolated natural product. A pre/post assessment was used to measure student learning gains and verify that students demonstrated proficiency of key learning…

  7. FAMILIARISATION AND RELIABILITY OF SPRINT TEST INDICES DURING LABORATORY AND FIELD ASSESSMENT

    Directory of Open Access Journals (Sweden)

    Andrew Galbraith

    2009-12-01

    Full Text Available The aim of the study was to assess the reliability of sprint performance in both field and laboratory conditions. Twenty-one male (mean ± s: 19 ± 1 years, 1.79 ± 0.07 m, 77.6 ± 7.1 kg and seventeen female team sport players (mean ± s: 21 ± 4 years, 1.68 ± 0. 07 m, 62.7 ± 4.7 kg performed a maximal 20-metre sprint running test on eight separate occasions. Four trials were conducted on a non-motorised treadmill in the laboratory; the other four were conducted outdoors on a hard-court training surface with time recorded by single-beam photocells. Trials were conducted in random order with no familiarisation prior to testing. There was a significant difference between times recorded during outdoor field trials (OFT and indoor laboratory trials (ILT using a non-motorised treadmill (3.47 ± 0.53 vs. 6.06 ±1.17s; p < 0.001. The coefficient of variation (CV for time was 2.55-4.22% for OFT and 5.1-7.2% for ILT. During ILT peak force (420.9 ± 87.7N, mean force (147.2 ± 24.7N, peak power (1376.8 ± 451.9W and mean power (514.8 ± 164.4W, and were measured. The CV for all ILT variables was highest during trial 1-2 comparison. The CV (95% confidence interval for the trial 3-4 comparison yielded: 9.4% (7.7-12. 1%, 7.9% (6.4-10.2%, 10.1% (8.2-13.1% and 6.2% (5.1-8.0% for PF, MF, PP and MP and respectively. The results indicate that reliable data can be derived for single maximal sprint measures, using fixed distance protocols. However, significant differences in time/speed over 20-m exist between field and laboratory conditions. This is primarily due to the frictional resistance in the non- motorised treadmill. Measures of force and power during ILT require at least 3 familiarisations to reduce variability in test scores

  8. Utilisation, Reliability and Validity of Clinical Evaluation Exercise in Otolaryngology Training.

    Science.gov (United States)

    Awad, Z; Hayden, L; Muthuswamy, K; Tolley, N S

    2015-10-01

    To investigate the utilisation, reliability and validity of clinical evaluation exercise (CEX) in otolaryngology training. Retrospective database analysis. Online assessment database. We analysed all CEXs submitted by north London core (CT) and speciality trainees (ST) in otolaryngology from 2010 to 2013. Internal consistency of the 7 CEX items rated as either O: outstanding, S: satisfactory or D: development required. Overall performance rating (pS) of 1-4 assessed against completion of training level. Receiver operating characteristic was used to describe CEX sensitivity and specificity. Overall score (cS), pS and the number of 'D'-rated items were used to investigate construct validity. One thousand one hundred and sixty CEXs from 45 trainees were included. CEX showed good internal consistency (Cronbach's alpha= 0.85). CEX was highly sensitive (99%), yet not specific (6%). cS and pS for ST was higher than CT (99.1% ± 0.4 versus 96.6% ± 0.8 and 3.06 ± 0.05 versus 1.92 ± 0.04, respectively P reliable in assessing early years otolaryngology trainees in clinical examination, but not at higher level. It has the potential to be used in a summative capacity in selecting trainees for ST positions. This would also encourage trainees to master all domains of otolaryngology clinical examination by end of CT. © 2015 John Wiley & Sons Ltd.

  9. Crew Exercise

    Science.gov (United States)

    Rafalik, Kerrie K.

    2017-01-01

    Johnson Space Center (JSC) provides research, engineering, development, integration, and testing of hardware and software technologies for exercise systems applications in support of human spaceflight. This includes sustaining the current suite of on-orbit exercise devices by reducing maintenance, addressing obsolescence, and increasing reliability through creative engineering solutions. Advanced exercise systems technology development efforts focus on the sustainment of crew's physical condition beyond Low Earth Orbit for extended mission durations with significantly reduced mass, volume, and power consumption when compared to the ISS.

  10. Intercomparison exercises

    International Nuclear Information System (INIS)

    Arunachalam, J.

    2007-01-01

    Intercomparison exercises are vital to many a national programmes. These are only tools available with the laboratories to prove their competence to an international audience and also for the accrediting agencies to assess a laboratory

  11. Inter-laboratory comparisons. Determination of actinides in excreta

    International Nuclear Information System (INIS)

    Berard, P.; Cavadore, D.; Harduin, J.C.

    1995-01-01

    Inter-laboratory tests are a means of assessing the analytical coherence of medical laboratories. In radio toxicology, this kind of exercise makes it possible to keep up with laboratory know-how and with the evolution and relative performances of analytical techniques (precision and reproducibility). However, the goal of the laboratories taking part in these annual exercises is not only to check the accuracy of their results. The analytical discussions and the chance to compare experience enrich the groups general competence. French biologists have been organizing annual radio toxicology intercomparison exercises since 1978. The exercises are carried out within the framework of a working group (GT1) operating under the aegis of the French Atomic Energy Commission's (CEA) Medical Coordinator. Using reports and diagrams which present the results obtained by the participants in the form of syntheses, the authors describe how the exercises for determining actinides in excreta (urine and faeces) are organized, how the results are evaluated in terms of the analytical methods used, and the improvements made in analytical and metrological performance. Up until 1985, these exercises were limited to French laboratories. Since then, the exercises have acquired an international dimension, opening up to include interested foreign radio chemists, initially from European laboratories, and now from laboratories worldwide. At the present time, 35 laboratories representing 9 countries take part regularly in these intercomparison exercises. (author). 6 refs., 9 figs

  12. Results of the Interlaboratory Exercise CNS/CIEMAT-05 among Environmental Radioactivity Laboratories (Vegetable Ash); Evaluacion de la Intercomparacion CSN/CIEMAT-2005 entre Laboratorios Nacionales Radiactividad Ambiental (Ceniza Vegetal)

    Energy Technology Data Exchange (ETDEWEB)

    Romero Gonzalez, M. L.; Barrera Izquierdo, M.; Valino Garcia, F.

    2006-07-01

    The document describes the outcome of the CSN/CIEMAT-05 interlaboratory test comparison among environmental radioactivity laboratories. The exercise was organised according to the ISO-43 and the IUPAC {sup I}nternational harmonised protocol for the proficiency testing of analytical chemistry laboratories{sup .} The exercise has been designed to evaluate the capability of national laboratories to determine environmental levels of radionuclides in vegetable ash samples. The sample has been prepared by the Environmental Radiation Laboratory, from the University of Barcelona, and it contains the following radionuclides: Sr-90, Pu-238, Am-241, Th-230, Pb-210, U-238, Ra-226, K-40, Ra-228, TI-208, Cs- 137 and Co-60. Reference values have been established TROUGH the kind collaboration of three international laboratories of recognized experience: IAEA MEL and IRSN-Orsay. The results of the exercise were computed for 35 participating laboratories and their analytical performance was assessed using the z-score approach. Robust statistics of the participant's results was applied to obtain the median and standard deviation, to achieve a more complete and objetiva study of the laboratories' performance. Some difficulties encountered to dissolve the test sample caused a lower response of analyses involving radiochemical separation, thus some laboratories couldn't apply their routine methods and no conclusions on PU-238, Am-241 and Th-230 performances have been obtained. The exercise has revealed an homogeneous behaviour of laboratories, being statistical parameters from the results close to the reference values. The study has shown that participant laboratories perform radioactive determinations in vegetable ash samples with satisfactory quality levels. (Author) 6 refs.

  13. "They Sweat for Science": The Harvard Fatigue Laboratory and Self-Experimentation in American Exercise Physiology.

    Science.gov (United States)

    Johnson, Andi

    2015-08-01

    In many scientific fields, the practice of self-experimentation waned over the course of the twentieth century. For exercise physiologists working today, however, the practice of self-experimentation is alive and well. This paper considers the role of the Harvard Fatigue Laboratory and its scientific director, D. Bruce Dill, in legitimizing the practice of self-experimentation in exercise physiology. Descriptions of self-experimentation are drawn from papers published by members of the Harvard Fatigue Lab. Attention is paid to the ethical and practical justifications for self-experimentation in both the lab and the field. Born out of the practical, immediate demands of fatigue protocols, self-experimentation performed the long-term, epistemological function of uniting physiological data across time and space, enabling researchers to contribute to a general human biology program.

  14. A Laboratory Exercise to Understand the Importance of Enzyme Technology in the Fruit-Processing Industry: Viscosity Decrease and Phenols Release from Apple Mash

    Science.gov (United States)

    Pinelo, Manuel; Nielsen, Michael K.; Meyer, Anne S.

    2011-01-01

    In a 4-h laboratory exercise, students accomplish a series of enzymatic macerations of apple mash, assess the viscosity of the mash during the maceration, extract the juice by centrifugation, and measure the levels of antioxidant phenols extracted into the juice after different enzyme treatments. The exercise shows the impact of enzyme-catalyzed…

  15. Laboratory Exercise for Studying the Morphology of Heat-Denatured and Amyloid Aggregates of Lysozyme by Atomic Force Microscopy

    Science.gov (United States)

    Gokalp, Sumeyra; Horton, William; Jónsdóttir-Lewis, Elfa B.; Foster, Michelle; Török, Marianna

    2018-01-01

    To facilitate learning advanced instrumental techniques, essential tools for visualizing biomaterials, a simple and versatile laboratory exercise demonstrating the use of Atomic Force Microscopy (AFM) in biomedical applications was developed. In this experiment, the morphology of heat-denatured and amyloid-type aggregates formed from a low-cost…

  16. Reliability of power and velocity variables collected during the traditional and ballistic bench press exercise.

    Science.gov (United States)

    García-Ramos, Amador; Haff, G Gregory; Padial, Paulino; Feriche, Belén

    2018-03-01

    This study aimed to examine the reliability of different power and velocity variables during the Smith machine bench press (BP) and bench press throw (BPT) exercises. Twenty-two healthy men conducted four testing sessions after a preliminary BP one-repetition maximum (1RM) test. In a counterbalanced order, participants performed two sessions of BP in one week and two sessions of BPT in another week. Mean propulsive power, peak power, mean propulsive velocity, and peak velocity at each tenth percentile (20-70% of 1RM) were recorded by a linear transducer. The within-participants coefficient of variation (CV) was higher for the load-power relationship compared to the load-velocity relationship in both the BP (5.3% vs. 4.1%; CV ratio = 1.29) and BPT (4.7% vs. 3.4%; CV ratio = 1.38). Mean propulsive variables showed lower reliability than peak variables in both the BP (5.4% vs. 4.0%, CV ratio = 1.35) and BPT (4.8% vs. 3.3%, CV ratio = 1.45). All variables were deemed reliable, with the peak velocity demonstrating the lowest within-participants CV. Based upon these findings, the peak velocity should be chosen for the accurate assessment of BP and BPT performance.

  17. A method to evaluate performance reliability of individual subjects in laboratory research applied to work settings.

    Science.gov (United States)

    1978-10-01

    This report presents a method that may be used to evaluate the reliability of performance of individual subjects, particularly in applied laboratory research. The method is based on analysis of variance of a tasks-by-subjects data matrix, with all sc...

  18. Exercise and Cognitive Functioning in People With Chronic Whiplash-Associated Disorders: A Controlled Laboratory Study.

    Science.gov (United States)

    Ickmans, Kelly; Meeus, Mira; De Kooning, Margot; De Backer, Annabelle; Kooremans, Daniëlle; Hubloue, Ives; Schmitz, Tom; Van Loo, Michel; Nijs, Jo

    2016-02-01

    Controlled laboratory study. In addition to persistent pain, people with chronic whiplash-associated disorders (WAD) commonly deal with cognitive dysfunctions. In healthy individuals, aerobic exercise has a positive effect on cognitive performance, and preliminary evidence in other chronic pain conditions reveals promising results as well. However, there is evidence that people with chronic WAD may show a worsening of the symptom complex following physical exertion. To examine postexercise cognitive performance in people with chronic WAD. People with chronic WAD (n = 27) and healthy, inactive, sex- and age-matched controls (n = 27) performed a single bout of an incremental submaximal cycling exercise. Before and after the exercise, participants completed 2 performance-based cognitive tests assessing selective and sustained attention, cognitive inhibition, and simple and choice reaction time. At baseline, people with chronic WAD displayed significantly lower scores on sustained attention and simple reaction time (Pselective attention, cognitive inhibition, and choice reaction time (P>.05), compared with healthy controls. Postexercise, both groups showed significantly improved selective attention and choice reaction time (chronic WAD, P = .001; control, Pattention, cognitive inhibition, pain, and fatigue were observed (P>.05). In the short term, postexercise cognitive functioning, pain, and fatigue were not aggravated in people with chronic WAD. However, randomized controlled trials are required to study the longer-term and isolated effects of exercise on cognitive functioning.

  19. Exercise addiction in CrossFit: Prevalence and psychometric properties of the Exercise Addiction Inventory.

    Science.gov (United States)

    Lichtenstein, Mia Beck; Jensen, Tanja Tang

    2016-06-01

    CrossFit is a mix of aerobic and anaerobic exercise regimes with the stated goal of improving fitness and physical performance. It is growing in popularity and has a strong community known to motivate and push the participants to maximal performance. The negative consequences of these extreme exercise patterns have rarely been described. The prevalence of injuries in CrossFit is high but exercise addiction and harmful exercise attitudes have not yet been assessed. The aim of this study was to measure the prevalence of exercise addiction in CrossFit and to evaluate the reliability and validity of the Exercise Addiction Inventory (EAI) in a CrossFit population. We invited crossfitters to participate in an online survey using Facebook groups. A total of 603 regular crossfitters completed the EAI and additional questions concerning exercise amounts and negative exercise attitudes and beliefs. We used principal component analyses and structural equation models to test the psychometric properties of the EAI and to describe the characteristics of the addicted crossfitters. We found that 5% of the crossfitters were addicted to exercise and that young males had a higher risk. The EAI had good internal reliability (0.73) and construct validity. Thus we found significant positive associations between exercise addiction and the tendency to exercise in spite of injury, feelings of guilt when unable to exercise, passion turning into obsession and taking medication to be able to exercise. Exercise addiction is prevalent in CrossFit and needs further exploration. The EAI is recommended for research in CrossFit communities and applied settings.

  20. Musk as a Pheromone? Didactic Exercise.

    Science.gov (United States)

    Bersted, Chris T.

    A classroom/laboratory exercise has been used to introduce college students to factorial research designs, differentiate between interpretations for experimental and quasi-experimental variables, and exemplify application of laboratory research methods to test practical questions (advertising claims). The exercise involves having randomly divided…

  1. Evaluating plyometric exercises using time to stabilization.

    Science.gov (United States)

    Ebben, William P; Vanderzanden, Tyler; Wurm, Bradley J; Petushek, Erich J

    2010-02-01

    Plyometric exercises are frequently used in strength and conditioning and rehabilitation programs because the landing phase of these exercises requires dynamic stabilization. This study examined the differences in landing stability of a variety of plyometric exercises by assessing time to stabilization (TTS), its reliability, and sex differences therein. Forty-nine men and women performed a variety of plyometric exercises thought to represent a continuum of difficulty of dynamic stabilization during landing. Plyometric exercises included line hops, cone hops, squat jumps, tuck jumps, countermovement jumps, dumbbell countermovement jumps, and single leg countermovement jumps, each performed for 3 repetitions on a force platform. A 2-way mixed analysis of covariance with repeated measures for plyometric exercise type was used to evaluate the main effects for plyometric exercise type and the interaction between plyometric exercise type and sex for TTS. Subject jumping ability was evaluated as a covariate. Results revealed significant main effects for plyometric exercise type (p plyometric exercise type and sex (p = 0.002). Bonferroni adjusted post hoc analysis demonstrated differences in TTS between a number of plyometric exercises for men and women. Reliability analysis revealed intraclass correlation coefficients ranging from 0.51 to 0.86 with no significant difference between trials (p > 0.05). Practitioners who use plyometrics to train dynamic stability should create programs that progress the intensity of the exercises based on the results of this study. This study also demonstrated that TTS is moderately to highly reliable for a variety of jumping conditions for both men and women.

  2. RENEB accident simulation exercise.

    Science.gov (United States)

    Brzozowska, Beata; Ainsbury, Elizabeth; Baert, Annelot; Beaton-Green, Lindsay; Barrios, Leonardo; Barquinero, Joan Francesc; Bassinet, Celine; Beinke, Christina; Benedek, Anett; Beukes, Philip; Bortolin, Emanuela; Buraczewska, Iwona; Burbidge, Christopher; De Amicis, Andrea; De Angelis, Cinzia; Della Monaca, Sara; Depuydt, Julie; De Sanctis, Stefania; Dobos, Katalin; Domene, Mercedes Moreno; Domínguez, Inmaculada; Facco, Eva; Fattibene, Paola; Frenzel, Monika; Monteiro Gil, Octávia; Gonon, Géraldine; Gregoire, Eric; Gruel, Gaëtan; Hadjidekova, Valeria; Hatzi, Vasiliki I; Hristova, Rositsa; Jaworska, Alicja; Kis, Enikő; Kowalska, Maria; Kulka, Ulrike; Lista, Florigio; Lumniczky, Katalin; Martínez-López, Wilner; Meschini, Roberta; Moertl, Simone; Moquet, Jayne; Noditi, Mihaela; Oestreicher, Ursula; Orta Vázquez, Manuel Luis; Palma, Valentina; Pantelias, Gabriel; Montoro Pastor, Alegria; Patrono, Clarice; Piqueret-Stephan, Laure; Quattrini, Maria Cristina; Regalbuto, Elisa; Ricoul, Michelle; Roch-Lefevre, Sandrine; Roy, Laurence; Sabatier, Laure; Sarchiapone, Lucia; Sebastià, Natividad; Sommer, Sylwester; Sun, Mingzhu; Suto, Yumiko; Terzoudi, Georgia; Trompier, Francois; Vral, Anne; Wilkins, Ruth; Zafiropoulos, Demetre; Wieser, Albrecht; Woda, Clemens; Wojcik, Andrzej

    2017-01-01

    The RENEB accident exercise was carried out in order to train the RENEB participants in coordinating and managing potentially large data sets that would be generated in case of a major radiological event. Each participant was offered the possibility to activate the network by sending an alerting email about a simulated radiation emergency. The same participant had to collect, compile and report capacity, triage categorization and exposure scenario results obtained from all other participants. The exercise was performed over 27 weeks and involved the network consisting of 28 institutes: 21 RENEB members, four candidates and three non-RENEB partners. The duration of a single exercise never exceeded 10 days, while the response from the assisting laboratories never came later than within half a day. During each week of the exercise, around 4500 samples were reported by all service laboratories (SL) to be examined and 54 scenarios were coherently estimated by all laboratories (the standard deviation from the mean of all SL answers for a given scenario category and a set of data was not larger than 3 patient codes). Each participant received training in both the role of a reference laboratory (activating the network) and of a service laboratory (responding to an activation request). The procedures in the case of radiological event were successfully established and tested.

  3. Results of the Interlaboratory Exercise CNS/CIEMAT-2008 among Environmental Radioactivity Laboratories (Phosphogypsum); Evaluacion de la Intercomparacion CSN/CIEMAT-2008 entre Laboratorios Nacionales de Radiactividad Ambiental (Fosfoyeso)

    Energy Technology Data Exchange (ETDEWEB)

    Romero, M L; Barrera, M; Valino, F

    2010-05-27

    The document describes the outcome of the CSN/CIEMAT-2008 interlaboratory test comparison among environmental radioactivity laboratories. The exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC. Aphosphogypsum material was used as a test sample, in an attempt to evaluate the performance of the laboratories analyzing NORM (Naturally-Occurring Radioactive Materials). The analysis required were: U-238, Th-234, U-234, Th-230, Ra-226, Pb-214, Bi-214, Pb-210, Po-210, Th-232 and U-235, and also gross alpha and gross beta activities. Reference values have been established according to the method of consensus of expert laboratories, with four international laboratories of credited experience: IAEA Seibersdorf, IAEA MEL, IRSN-Orsay and Sta.Teresa ENEA. The results of the exercise were computed for 34 answering laboratories and their analytical performance was assessed using the z-score. Robust statistics of the participants results was applied to obtain the median and standard deviation, to achieve a more complete and objective study of the laboratories performance. The exercise has shown an homogeneous behaviour of laboratories, being statistical parameters from the results close to the assigned Reference Values. Participant laboratories have demonstrated their ability to determine natural radionuclides in phosphogypsum samples (NORM material) with a satisfactory quality level. The scheme has also allowed examining the capability of laboratories to determine the activities of natural radionuclides at the equilibrium. (Author) 10 refs.

  4. Validity and reliability of a novel iPhone app for the measurement of barbell velocity and 1RM on the bench-press exercise

    OpenAIRE

    Balsalobre Fernández, Carlos; Marchante Domingo, David; Muñoz López, Mario; Jiménez Sáiz, Sergio Lorenzo

    2018-01-01

    The purpose of this study was to analyse the validity and reliability of a novel iPhone app (named: PowerLift) for the measurement of mean velocity on the bench-press exercise. Additionally, the accuracy of the estimation of the 1-Repetition maximum (1RM) using the load-velocity relationship was tested. To do this, 10 powerlifters (Mean (SD): age = 26.5 ± 6.5 years; bench press 1RM · kg-1 = 1.34 ± 0.25) completed an incremental test on the bench-press exercise with 5 different loads (75-100% ...

  5. Mobile spectrometric laboratory

    International Nuclear Information System (INIS)

    Isajenko, K.A.; Lipinski, P.

    2002-01-01

    The article presents the Mobile Spectrometric Laboratory used by Central Laboratory for Radiological Protection since year 2000. The equipment installed in the Mobile Laboratory and its uses is described. The results of international exercises and intercalibrations, in which the Laboratory participated are presented. (author)

  6. Laboratory and field evaluation of the impact of exercise on the performance of regular and polymer-based deet repellents.

    Science.gov (United States)

    Schofield, Steven; Tepper, Martin; Gadawski, Randy

    2007-11-01

    Studies were done in Manitoba, Canada, to evaluate the impact of exercise on repellent performance against mosquitoes. Two products containing the active ingredient N,N-diethyl-3-methylbenzamide (deet) were tested; one product was a polymer-based cream (3M Ultrathon Insect Repellent) and the other product was an alcohol-based pump spray formulation (Muskol Insect Repellent). Assessments were done in the laboratory using Aedes aegypti (L.) and in the field with naturally occurring populations of mosquitoes. Repellent was applied to the forearms (laboratory) or a lower leg (field) of test subjects at 1.5 g of test product per 600 cm2 surface area (0.75 or 0.83 mg deet/cm2). For a given test day, subjects exercised or did not. Exposure to mosquito attack was for 1 min at 30-min intervals in laboratory procedures, and it was continuous in field tests. Performance was measured as complete protection time (CPT). Moderate levels of physical activity resulted in a >40% decline in mean CPT, from 468 to 267 min in the laboratory experiments and from 359 to 203 min in field tests. Repellent product did not affect the magnitude of the decline. Mean biting pressure during field trials was 21.3 bites per min, and mosquito collections were made up primarily of Ochlerotatus sticticus (Meigen) and Aedes vexans (Meigen).

  7. Harmonization of European laboratory response networks by implementing CWA 15793: use of a gap analysis and an "insider" exercise as tools.

    Science.gov (United States)

    Sundqvist, Bo; Bengtsson, Ulrika Allard; Wisselink, Henk J; Peeters, Ben P H; van Rotterdam, Bart; Kampert, Evelien; Bereczky, Sándor; Johan Olsson, N G; Szekely Björndal, Asa; Zini, Sylvie; Allix, Sébastien; Knutsson, Rickard

    2013-09-01

    Laboratory response networks (LRNs) have been established for security reasons in several countries including the Netherlands, France, and Sweden. LRNs function in these countries as a preparedness measure for a coordinated diagnostic response capability in case of a bioterrorism incident or other biocrimes. Generally, these LRNs are organized on a national level. The EU project AniBioThreat has identified the need for an integrated European LRN to strengthen preparedness against animal bioterrorism. One task of the AniBioThreat project is to suggest a plan to implement laboratory biorisk management CWA 15793:2011 (CWA 15793), a management system built on the principle of continual improvement through the Plan-Do-Check-Act (PDCA) cycle. The implementation of CWA 15793 can facilitate trust and credibility in a future European LRN and is an assurance that the work done at the laboratories is performed in a structured way with continuous improvements. As a first step, a gap analysis was performed to establish the current compliance status of biosafety and laboratory biosecurity management with CWA 15793 in 5 AniBioThreat partner institutes in France (ANSES), the Netherlands (CVI and RIVM), and Sweden (SMI and SVA). All 5 partners are national and/or international laboratory reference institutes in the field of public or animal health and possess high-containment laboratories and animal facilities. The gap analysis showed that the participating institutes already have robust biorisk management programs in place, but several gaps were identified that need to be addressed. Despite differences between the participating institutes in their compliance status, these variations are not significant. Biorisk management exercises also have been identified as a useful tool to control compliance status and thereby implementation of CWA 15793. An exercise concerning an insider threat and loss of a biological agent was performed at SVA in the AniBioThreat project to evaluate

  8. The validity and reliability of the exercise benefits/barriers scale for ...

    African Journals Online (AJOL)

    The exercise barrier subscale with the lowest score was “exercise milieu”. Determining the benefits of and barriers to exercise, by using a standardized scale, plays an important role in maintaining proper levels of physical activity. The Turkish translation of the EBBS model has shown it to be an effective tool for measuring ...

  9. 1982 radon intercomparison exercises at EML

    International Nuclear Information System (INIS)

    Fisenne, I.M.; George, A.C.; Keller, H.W.

    1983-03-01

    This report summarizes the results of two radon measurement intercomparison exercises held in 1982. Sixteen organizations, including five United States federal departments, two state governments, two national laboratories, three universities, three private sector laboratories and Swedish National Institute participated in these exercises. The results indicate good agreement among the participants at the 30 pCi 222 Rn/L level. With the continued interest and cooperation of groups involved in radon measurements, twp intercomparison exercises are planned during 1983

  10. Locking Editor A Utility For Protecting Software Exercises In The Computer Laboratory Of AMA University

    Directory of Open Access Journals (Sweden)

    Paul M. Grafilon

    2017-07-01

    because it is not until the entire program is linked that some errors can be detected. Assuming the linker finds all the variables and functions it produces a file that can be run. If the program is running and working means all well for the developer. If it seems to do nothing that means its debugging time since there is no insight to what the program is doing the developer may go back and put in some brute force methods like print statements to print messages out at certain points in the program or blink some light emitting diodes LEDs at strategic places which means back to the editor and the cycle continues. These are the causes of the developer can sort of sounds like rather than copying and pasting code from previous applications into a new one that are rewriting the same functionality again and again. This is one of the varied reasons of the dry principle is geared more towards not having the same functionality duplicated throughout an entire system but reusing code from other applications is better than rewriting it since IDE is free and available as open source in any codes of environment. The main focus of the study is the development of utility for locking editor in protecting software exercises. Specifically it sought to solve the following To develop an editor that will lock the source code during programming laboratory exercises To assess the propose system in Kirkpatrick model approach To evaluate the testing assessment of the proposed system in terms of the following indicators Efficiency Usability and reliability As the result the locking editor for source code generation is a core program for the locking IDE software. It contains both the user interface such as students and instructor which work together in one package. The evaluation of multi-programming environment by testing the editor that as it develops solutions keep in mind that locking editor uses the architecture and frameworks that most users are accustomed to see. It should build the

  11. Improving the reliability of GUB-20000 gamma unit for large laboratory animals irradiation

    International Nuclear Information System (INIS)

    Videnskij, V.G.

    1994-01-01

    GUB-20000 gamma unit for large laboratory animals irradiation is described and results of investigation into its reliability improvement are considered. Cables of superstrength high-modular (SSHM) polymer fibre and capron fiber were tested to establish their applicability in the above unit. Samples were exposed to gamma-radiation and fast electrons and were tested for tensile properties. Application of SSHM-fiber cables to modernize the GUB-20000 unit was found to be perspective due to superhigh radiation strength. 5 refs., 1 tab

  12. Laboratory Exercises in 80537-Microcontroller Programming

    DEFF Research Database (Denmark)

    Pedersen, Knud Ole Helgesen

    1998-01-01

    The main goal of the 3-weeks course 53113: "Microprocessor Applications in the Electric Power System" is to program a digital distance relay using a 80537-microcontroller system. The microprocessor techniques necessary to solve this problem are introduced gradually through exercises. The final...

  13. The Effectiveness of Hands-on Health Informatics Skills Exercises in the Multidisciplinary Smart Home Healthcare and Health Informatics Training Laboratories.

    Science.gov (United States)

    Sapci, A H; Sapci, H A

    2017-10-01

    This article aimed to evaluate the effectiveness of newly established innovative smart home healthcare and health informatics laboratories, and a novel laboratory course that focuses on experiential health informatics training, and determine students' self-confidence to operate wireless home health monitoring devices before and after the hands-on laboratory course. Two web-based pretraining and posttraining questionnaires were sent to 64 students who received hands-on training with wireless remote patient monitoring devices in smart home healthcare and health informatics laboratories. All 64 students completed the pretraining survey (100% response rate), and 49 students completed the posttraining survey (76% response rate). The quantitative data analysis showed that 95% of students had an interest in taking more hands-on laboratory courses. Sixty-seven percent of students had no prior experience with medical image, physiological data acquisition, storage, and transmission protocols. After the hands-on training session, 75.51% of students expressed improved confidence about training patients to measure blood pressure monitor using wireless devices. Ninety percent of students preferred to use a similar experiential approach in their future learning experience. Additionally, the qualitative data analysis demonstrated that students were expecting to have more courses with hands-on exercises and integration of technology-enabled delivery and patient monitoring concepts into the curriculum. This study demonstrated that the multidisciplinary smart home healthcare and health informatics training laboratories and the hands-on exercises improved students' technology adoption rates and their self-confidence in using wireless patient monitoring devices. Schattauer GmbH Stuttgart.

  14. An interlaboratory comparison exercise for organohalogens in marine mammal blubber

    Energy Technology Data Exchange (ETDEWEB)

    Kucklick, J.; Becker, P.; Pugh, R. [NIST, Hollings Marine Lab., Charleston (United States); Schantz, M.; Porter, B.; Wise, S. [NIST, Gaithersburg (United States); Rowles, T. [NOAA, Silversprings (United States)

    2004-09-15

    For analytical data generated on marine mammal tissues, such as blubber, harmonizing measurements of organohalogen compounds is very important. Often organohalogen data on marine mammal samples from different laboratories are combined to provide an indication of geographical trends or to help ascertain toxicological significance. In at least one study that combined data on organohalogen concentrations from marine mammal blubber to examine geographical trends, it was found that among laboratory variability contributed significantly to the observed data variability (Schwacke, personal communication). To help resolve such problems, NIST and the National Oceanic and Atmospheric Administration (NOAA) initiated an interlaboratory comparison exercise program patterned after the exercise described above but using marine mammal blubber as the exercise materials. The objective of this paper is to describe the exercises, summarize selected results, and discuss the value of these interterlaboratory comparison exercises. The exercises have been held on a small scale (<10 laboratories) starting in 1991 and on a larger scale (10 or more laboratories) starting in 1999. Twenty-four laboratories participated in the 2003 exercise.

  15. Teaching Baroreflex Physiology to Medical Students: A Comparison of Quiz-Based and Conventional Teaching Strategies in a Laboratory Exercise

    Science.gov (United States)

    Berg, Ronan M. G.; Plovsing, Ronni R.; Damgaard, Morten

    2012-01-01

    Quiz-based and collaborative teaching strategies have previously been found to be efficient for the improving meaningful learning of physiology during lectures. These approaches have, however, not been investigated during laboratory exercises. In the present study, we compared the impact of solving quizzes individually and in groups with…

  16. Pasteurization: A reliable method for preservation of nutrient in seawater samples for inter-laboratory and field applications

    OpenAIRE

    Daniel, Anne; Kerouel, Roger; Aminot, Alain

    2012-01-01

    Following previous work, the production of reference material for nutrients in seawater, using pasteurization as a preservation method, was carried out seven times between 2006 and 2010 in the framework of inter-laboratory exercises. The preparation of samples from natural seawater allowed to become depleted in nutrients then spiked, bottled and pasteurized, is described. Five main nutrients are involved in this study: ammonium, nitrite, nitrate, phosphate and silicate. Bottles are in glass f...

  17. The Question-Driven Laboratory Exercise: A New Pedagogy Applied to a Green Modification of Grignard Reagent Formation and Reaction

    Science.gov (United States)

    Teixeira, Jennifer M.; Byers, Jessie Nedrow; Perez, Marilu G.; Holman, R. W.

    2010-01-01

    Experimental exercises within second-year-level organic laboratory manuals typically involve a statement of a principle that is then validated by student generation of data in a single experiment. These experiments are structured in the exact opposite order of the scientific method, in which data interpretation, typically from multiple related…

  18. Forensic ancestry analysis with two capillary electrophoresis ancestry informative marker (AIM) panels: Results of a collaborative EDNAP exercise.

    Science.gov (United States)

    Santos, C; Fondevila, M; Ballard, D; Banemann, R; Bento, A M; Børsting, C; Branicki, W; Brisighelli, F; Burrington, M; Capal, T; Chaitanya, L; Daniel, R; Decroyer, V; England, R; Gettings, K B; Gross, T E; Haas, C; Harteveld, J; Hoff-Olsen, P; Hoffmann, A; Kayser, M; Kohler, P; Linacre, A; Mayr-Eduardoff, M; McGovern, C; Morling, N; O'Donnell, G; Parson, W; Pascali, V L; Porto, M J; Roseth, A; Schneider, P M; Sijen, T; Stenzl, V; Court, D Syndercombe; Templeton, J E; Turanska, M; Vallone, P M; Oorschot, R A H van; Zatkalikova, L; Carracedo, Á; Phillips, C

    2015-11-01

    There is increasing interest in forensic ancestry tests, which are part of a growing number of DNA analyses that can enhance routine profiling by obtaining additional genetic information about unidentified DNA donors. Nearly all ancestry tests use single nucleotide polymorphisms (SNPs), but these currently rely on SNaPshot single base extension chemistry that can fail to detect mixed DNA. Insertion-deletion polymorphism (Indel) tests have been developed using dye-labeled primers that allow direct capillary electrophoresis detection of PCR products (PCR-to-CE). PCR-to-CE maintains the direct relationship between input DNA and signal strength as each marker is detected with a single dye, so mixed DNA is more reliably detected. We report the results of a collaborative inter-laboratory exercise of 19 participants (15 from the EDNAP European DNA Profiling group) that assessed a 34-plex SNP test using SNaPshot and a 46-plex Indel test using PCR-to-CE. Laboratories were asked to type five samples with different ancestries and detect an additional mixed DNA sample. Statistical inference of ancestry was made by participants using the Snipper online Bayes analysis portal plus an optional PCA module that analyzes the genotype data alongside calculation of Bayes likelihood ratios. Exercise results indicated consistent genotyping performance from both tests, reaching a particularly high level of reliability for the Indel test. SNP genotyping gave 93.5% concordance (compared to the organizing laboratory's data) that rose to 97.3% excluding one laboratory with a large number of miscalled genotypes. Indel genotyping gave a higher concordance rate of 99.8% and a reduced no-call rate compared to SNP analysis. All participants detected the mixture from their Indel peak height data and successfully assigned the correct ancestry to the other samples using Snipper, with the exception of one laboratory with SNP miscalls that incorrectly assigned ancestry of two samples and did not obtain

  19. Reliability of the exercise ECG in detecting silent ischemia in patients with prior myocardial infarction

    International Nuclear Information System (INIS)

    Yamagishi, Takashi; Matsuda, Yasuo; Satoh, Akira

    1991-01-01

    To assess the reliability of the exercise ECG in detecting silent ischemia, ECG results were compared with those of stress-redistribution thallium-201 single-photon emission computed tomography (SPECT) in 116 patients with prior myocardial infarction and in 20 normal subjects used as a control. The left ventricle (LV) was divided into 20 segmental images, which were scored blindly on a 5-point scale. The redistribution score was defined as thallium defect score of exercise subtracted by that of redistribution image and was used as a measure of amount of ischemic but viable myocardium. The upper limit of normal redistribution score (=4.32) was defined as mean+2 standard deviations derived from 20 normal subjects. Of 116 patients, 47 had the redistribution score above the normal range. Twenty-five (53%) of the 47 patients showed positive ECG response. Fourteen (20%) of the 69 patients, who had the normal redistribution score, showed positive ECG response. Thus, the ECG response had a sensitivity of 53% and a specificity of 80% in detecting transient ischemia. Furthermore, the 116 patients were subdivided into 4 groups according to the presence or absence of chest pain and ECG change during exercise. Fourteen patients showed both chest pain and ECG change and all these patients had the redistribution score above the normal range. Twenty-five patients showed ECG change without chest pain and 11 (44%) of the 25 patients had the abnormal redistribution. Three (43%) of 7 patients who showed chest pain without ECG change had the abnormal redistribution score. Of 70 patients who had neither chest pain nor ECG change, 19 (27%) had the redistribution score above the normal range. Thus, limitations exist in detecting silent ischemia by ECG in patients with a prior myocardial infarction, because the ECG response to the exercise test may have a low degree of sensitivity and a high degree of false positive and false negative results in detecting silent ischemia. (author)

  20. A streamlined Western blot exercise: An efficient and greener approach in the laboratory classroom.

    Science.gov (United States)

    Ness, Traci L; Robinson, Rebekah L; Mojadedi, Wais; Peavy, Lydia; Weiland, Mitch H

    2015-01-01

    SDS-PAGE and western blotting are two commonly taught protein detection techniques in biochemistry and molecular biology laboratory classrooms. A pitfall associated with incorporating these techniques into the laboratory is the significant wait times that do not allow students to obtain timely results. The waiting associated with SDS-PAGE comes from staining and destaining, whereas with western blotting it is the times required for antibody incubations and the numerous wash steps. This laboratory exercise incorporates 2,2,2-trichloroethanol (TCE) into the SDS-PAGE gel allowing for visualization of migrated proteins in a matter of minutes, saving both the time and chemical waste associated with traditional Coomassie staining. Additionally, TCE staining does not affect protein transfer eliminating the requirement for duplicated gels for total protein and western analyses. Protein transfer can be confirmed immediately without the use of Ponceau S staining. Lastly, this western blot procedure has been further shortened by using an HRP-conjugated primary antibody, which eliminates the secondary antibody incubation and washes, and uses a colorimetric detection to allow for visualization by students without the need for specialized equipment. © 2015 The International Union of Biochemistry and Molecular Biology.

  1. Modernisation of the intermediate physics laboratory

    Science.gov (United States)

    Kontro, Inkeri; Heino, Olga; Hendolin, Ilkka; Galambosi, Szabolcs

    2018-03-01

    The intermediate laboratory courses at the Department of Physics, University of Helsinki, were reformed using desired learning outcomes as the basis for design. The reformed laboratory courses consist of weekly workshops and small-group laboratory sessions. Many of the laboratory exercises are open-ended and have several possible ways of execution. They were designed around affordable devices, to allow for the purchase of multiple sets of laboratory equipment. This allowed students to work on the same problems simultaneously. Thus, it was possible to set learning goals which build on each other. Workshop sessions supported the course by letting the students solve problems related to conceptual and technical aspects of each laboratory exercise. The laboratory exercises progressed biweekly to allow for iterative problem solving. Students reached the learning goals well and the reform improved student experiences. Neither positive or negative changes in expert-like attitudes towards experimental physics (measured by E-CLASS questionnaire) were observed.

  2. Reliability and accuracy of a video analysis protocol to assess core ability.

    Science.gov (United States)

    McDonald, Dawn A; Delgadillo, James Q; Fredericson, Michael; McConnell, Jennifer; Hodgins, Melissa; Besier, Thor F

    2011-03-01

    To develop and test a method to measure core ability in healthy athletes with 2-dimensional video analysis software (SiliconCOACH). Specific objectives were to: (1) develop a standardized exercise battery with progressions of increasing difficulty to evaluate areas of core ability in elite athletes; (2) develop an objective and quantitative grading rubric with the use of video analysis software; (3) assess the test-retest reliability of the exercise battery; (4) assess the interrater and intrarater reliability of the video analysis system; and (5) assess the accuracy of the assessment. Test-retest repeatability and accuracy. Testing was conducted in the Stanford Human Performance Laboratory, Stanford University, Stanford, CA. Nine female gymnasts currently training with the Stanford Varsity Women's Gymnastics Team participated in testing. Participants completed a test battery composed of planks, side planks, and leg bridges of increasing difficulty. Subjects completed two 20-minute testing sessions within a 4- to 10-day period. Two-dimensional sagittal-plane video was captured simultaneously with 3-dimensional motion capture. The main outcome measures were pelvic displacement and time that elapsed until failure occurred, as measured with SiliconCOACH video analysis software. Test-retest and interrater and intrarater reliability of the video analysis measures was assessed. Accuracy as compared with 3-dimensional motion capture also was assessed. Levels reached during the side planks and leg bridges had an excellent test-retest correlation (r(2) = 0.84, r(2) = 0.95). Pelvis displacements measured by examiner 1 and examiner 2 had an excellent correlation (r(2) = 0.86, intraclass correlation coefficient = 0.92). Pelvis displacements measured by examiner 1 during independent grading sessions had an excellent correlation (r(2) = 0.92). Pelvis displacements from the plank and from a set of combined plank and side plank exercises both had an excellent correlation with 3

  3. Results of the Interlaboratory Exercise CSN/CIEMAT-02 Among Environmental Radioactivity Laboratories (Sea Fish); Resultados del Ejercicio Interlaboratorios de Radiactividad Ambiental CSN/CIEMAT-02 (Fauna Marina)

    Energy Technology Data Exchange (ETDEWEB)

    Romero gonzalez, M. L.

    2003-07-01

    The document describes the outcome of the CSN/CIEMAT-02 interlaboratory test comparison among environmental radioactivity laboratories. The exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC Harmonized Protocol for the proficiency testing of analytical laboratories. The test sample was a reference materials provided by the IAEA-MEL (IAE Marine Environmental Laboratory, Monaco), a sea fish containing environmental levels of U-238, U-234, K-40, Pb-210, Ra-226, Sr-90, Cs-137, Co-60, Pu-(239+240), Am-241 and Tc-99. The results of the exercise were computed for 32 participating laboratories, and their analytical performance was assessed using the z-score approach. A raised percentage of satisfactory laboratory performance has been obtained for all the analysis, being the best performance in gamma measurements. The laboratories have made an effort to calculate the combined uncertainty of the radiochemical determinations. Most of the laboratories have demonstrated its competence in performing the study analysis and also the adequate measuring capability of their detection equipment even in conditions close to detection limits. The study has shown the capacity of participant laboratories to perform radioactive determinations in environmental sea fish samples with satisfactory quality levels. (Author) 6 refs.

  4. Kinetics of Carbaryl Hydrolysis: An Undergraduate Environmental Chemistry Laboratory

    Science.gov (United States)

    Hawker, Darryl

    2015-01-01

    Kinetics is an important part of undergraduate environmental chemistry curricula and relevant laboratory exercises are helpful in assisting students to grasp concepts. Such exercises are also useful in general chemistry courses because students can see relevance to real-world issues. The laboratory exercise described here involves determination of…

  5. SPORT AND EXERCISE PHYSIOLOGY TESTING Volume one: Sport Testing Volume two: Exercise and Clinical Testing

    Directory of Open Access Journals (Sweden)

    Edward M. Winter

    2007-03-01

    Full Text Available DESCRIPTION The objective of the book is to discuss the theoretical and practical aspects of physiological testing in exercise and sports which is essential to evaluate and monitor developing exercise performance for athletes and public health, and improving quality of life for patients.A board of leading sport and exercise physiologists and scientists are gathered to discuss physiological assessments that have proven validity and reliability, both in sport and health relevant issues. Incidentally, it updates the reader about the current subjects of physiological exertion testing in both research and clinical procedures. Both volumes individually cover the increasing number of available research and review publications, and theoretical explanations are supported by practical examples. A step-by-step and/or checklist method is used in appropriate sections which make the guides more user-friendly than most. PURPOSE The first volume is designed to help readers develop an understanding of the essential concepts of sport specific testing whereas the second volume aims at making the exercise and clinical specific testing comprehensible, dealing with both technical terms and the theories underlying the importance of these tests. AUDIENCE As Guidelines books of the British Association of Sport and Exercise Sciences, it will be of interest to a wide range of students, researchers and practitioners in the sport and exercise disciplines whether they work in the laboratory or in the field. FEATURES The first volume features immediate practical requirements particularly in sport testing. It is composed of five parts with detailed sub-sections in all of them. The topics of the parts are: i general principles, ii methodological issues, iii general procedures, iv sport specific procedures, v special populations.The second volume is also presented in five parts, again with sub-sections in all of them, but considering the requirements in clinical and exercise

  6. Actin Immobilization on Chitin for Purifying Myosin II: A Laboratory Exercise That Integrates Concepts of Molecular Cell Biology and Protein Chemistry

    Science.gov (United States)

    de Souza, Marcelle Gomes; Grossi, Andre Luiz; Pereira, Elisangela Lima Bastos; da Cruz, Carolina Oliveira; Mendes, Fernanda Machado; Cameron, Luiz Claudio; Paiva, Carmen Lucia Antao

    2008-01-01

    This article presents our experience on teaching biochemical sciences through an innovative approach that integrates concepts of molecular cell biology and protein chemistry. This original laboratory exercise is based on the preparation of an affinity chromatography column containing F-actin molecules immobilized on chitin particles for purifying…

  7. How Reliable Is Laboratory Testing?

    Science.gov (United States)

    ... type of container and mixed with the right preservative, when appropriate. The laboratory staff who collect samples ... avoid known interferences. You may be instructed to fast or avoid certain foods or activities. Carefully follow these instructions to prepare ...

  8. Estimating The Reliability of the Lawrence Livermore National Laboratory (LLNL) Flash X-ray (FXR) Machine

    International Nuclear Information System (INIS)

    Ong, M M; Kihara, R; Zentler, J M; Kreitzer, B R; DeHope, W J

    2007-01-01

    At Lawrence Livermore National Laboratory (LLNL), our flash X-ray accelerator (FXR) is used on multi-million dollar hydrodynamic experiments. Because of the importance of the radiographs, FXR must be ultra-reliable. Flash linear accelerators that can generate a 3 kA beam at 18 MeV are very complex. They have thousands, if not millions, of critical components that could prevent the machine from performing correctly. For the last five years, we have quantified and are tracking component failures. From this data, we have determined that the reliability of the high-voltage gas-switches that initiate the pulses, which drive the accelerator cells, dominates the statistics. The failure mode is a single-switch pre-fire that reduces the energy of the beam and degrades the X-ray spot-size. The unfortunate result is a lower resolution radiograph. FXR is a production machine that allows only a modest number of pulses for testing. Therefore, reliability switch testing that requires thousands of shots is performed on our test stand. Study of representative switches has produced pre-fire statistical information and probability distribution curves. This information is applied to FXR to develop test procedures and determine individual switch reliability using a minimal number of accelerator pulses

  9. Evaluation of the Most Reliable Procedure of Determining Jump Height During the Loaded Countermovement Jump Exercise: Take-Off Velocity vs. Flight Time.

    Science.gov (United States)

    Pérez-Castilla, Alejandro; García-Ramos, Amador

    2018-07-01

    Pérez-Castilla, A and García-Ramos, A. Evaluation of the most reliable procedure of determining jump height during the loaded countermovement jump exercise: Take-off velocity vs. flight time. J Strength Cond Res 32(7): 2025-2030, 2018-This study aimed to compare the reliability of jump height between the 2 standard procedures of analyzing force-time data (take-off velocity [TOV] and flight time [FT]) during the loaded countermovement (CMJ) exercise performed with a free-weight barbell and in a Smith machine. The jump height of 17 men (age: 22.2 ± 2.2 years, body mass: 75.2 ± 7.1 kg, and height: 177.0 ± 6.0 cm) was tested in 4 sessions (twice for each CMJ type) against external loads of 17, 30, 45, 60, and 75 kg. Jump height reliability was comparable between the TOV (coefficient of variation [CV]: 6.42 ± 2.41%) and FT (CV: 6.53 ± 2.17%) during the free-weight CMJ, but it was higher for the FT when the CMJ was performed in a Smith machine (CV: 11.34 ± 3.73% for TOV and 5.95 ± 1.12% for FT). Bland-Altman plots revealed trivial differences (≤0.27 cm) and no heteroscedasticity of the errors (R ≤ 0.09) for the jump height obtained by the TOV and FT procedures, whereas the random error between both procedures was higher for the CMJ performed in the Smith machine (2.02 cm) compared with the free-weight barbell (1.26 cm). Based on these results, we recommend the FT procedure to determine jump height during the loaded CMJ performed in a Smith machine, whereas the TOV and FT procedures provide similar reliability during the free-weight CMJ.

  10. Reliability of the Swedish version of the Exercise Self-Efficacy Scale (S-ESES): a test-retest study in adults with neurological disease.

    Science.gov (United States)

    Ahlström, Isabell; Hellström, Karin; Emtner, Margareta; Anens, Elisabeth

    2015-03-01

    To examine the test-retest reliability of the Swedish translated version of the Exercise Self-Efficacy Scale (S-ESES) in people with neurological disease and to examine internal consistency. Test-retest study. A total of 30 adults with neurological diseases including: Parkinson's disease; Multiple Sclerosis; Cervical Dystonia; and Charcot-Marie-Tooth disease. The S-ESES was sent twice by surface mail. Completion interval mean was 16 days apart. Weighted kappa, intraclass correlation coefficient 2,1 [ICC (2,1)], standard error of measurement (SEM), also expressed as a percentage value (SEM%), and Cronbach's alpha were calculated. The relative reliability of the test-retest results showed substantial agreement measured using weighted kappa (MD = 0.62) and a very high-reliability ICC (2,1) (0.92). Absolute reliability measured using SEM was 5.3 and SEM% was 20.7. Excellent internal consistency was shown, with an alpha coefficient of 0.91 (test 1) and 0.93 (test 2). The S-ESES is recommended for use in research and in clinical work for people with neurological diseases. The low-absolute reliability, however, indicates a limited ability to measure changes on an individual level.

  11. Predictive Accuracy of Exercise Stress Testing the Healthy Adult.

    Science.gov (United States)

    Lamont, Linda S.

    1981-01-01

    Exercise stress testing provides information on the aerobic capacity, heart rate, and blood pressure responses to graded exercises of a healthy adult. The reliability of exercise tests as a diagnostic procedure is discussed in relation to sensitivity and specificity and predictive accuracy. (JN)

  12. National intercomparison on in vivo measurement of Iodine-131 in the thyroid within a Brazilian Internal Dosimetry Laboratory Network - IAEA PROJECT BRA9055; Intercomparacao nacional de medicao in vivo de Iodo-131 na tireoide - Projeto TC IAEA BRA 9055

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, B.M.; Dantas, A.L.A.; Lucena, E.A., E-mail: bmdantas@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro (Brazil); Cardoso, J.S. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Ramos, M.A.P.; Sa, M.S. [Eletrobras Eletronuclear, Angra dos Reis, RJ (Brazil); Alonso, T.C.; Silva, T.V.; Oliveira, C.M. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Lima, F.F.; Oliveira, M.L.; Lacerda, I.V.B. [Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Fajgelj, A. [International Atomic Energy Agency (IAEA), Vienna (Austria)

    2013-08-15

    In 2011, in Brazil, a National Intercalibration and Intercomparison exercise on in vivo measurement of iodine-131 in the thyroid was carried out in the scope of the Project IAEABRA9055 'Establishing a National Laboratory Network for Internal Individual Monitoring'. The exercise was conducted by the Institute for Radiation Protection and Dosimetry (IRD) and the Institute for Nuclear and Energetic Research (IPEN), from National Nuclear Energy Commission (CNEN). The objectives of the exercise were to (i) update information on current instrumentation resources available in the in vivo monitoring laboratories in operation in Brazil and to (ii) verify the reliability of the results of measurements of iodine-131 in thyroid provided by those laboratories. The procedure consisted on the measurement of a neck-thyroid anthropomorphic phantom provided by the In Vivo Monitoring Laboratory of IRD, containing two barium-133 standard sources certified by the National Laboratory for Metrology of Ionizing Radiation. Each participant should measure the phantom in a period of five days. The five laboratories are located in the States of Rio de Janeiro, Sao Paulo, Minas Gerais and Pernambuco, in the following Institutions: Institute for Radiation Protection and Dosimetry, Nuclear Power Station Almirante Alvaro Alberto, Center for the Development of Nuclear Technology, Institute for Nuclear and Energetic Research, and Regional Center for Nuclear Sciences. The results reported included: activity measured, minimum detectable activity, accuracy and precision. The performance of the laboratories was evaluated according to the criteria suggested by ANSI 13.30 indicating their capacity to provide reliable results of iodine-131 content in the thyroid. (author)

  13. Testing for Exercise-Induced Bronchoconstriction

    DEFF Research Database (Denmark)

    Brannan, John D; Porsbjerg, Celeste

    2018-01-01

    of an individual who may be at risk during a recreational sporting activity or when exercising as an occupational duty. EIB can be identified with laboratory exercise testing or surrogate tests for EIB. These include eucapnic voluntary hyperpnea and osmotic stimuli (eg, inhaled mannitol) and offer improved...

  14. Dicentric chromosome aberration analysis using giemsa and centromere specific fluorescence in-situ hybridization for biological dosimetry: An inter- and intra-laboratory comparison in Indian laboratories

    International Nuclear Information System (INIS)

    Bhavani, M.; Tamizh Selvan, G.; Kaur, Harpreet; Adhikari, J.S.; Vijayalakshmi, J.; Venkatachalam, P.; Chaudhury, N.K.

    2014-01-01

    To facilitate efficient handling of large samples, an attempt towards networking of laboratories in India for biological dosimetry was carried out. Human peripheral blood samples were exposed to 60 Co γ-radiation for ten different doses (0–5 Gy) at a dose rate of 0.7 and 2 Gy/min. The chromosomal aberrations (CA) were scored in Giemsa-stained and fluorescence in-situ hybridization with centromere-specific probes. No significant difference (p>0.05) was observed in the CA yield for given doses except 4 and 5 Gy, between the laboratories, among the scorers and also staining methods adapted suggest the reliability and validates the inter-lab comparisons exercise for triage applications. - Highlights: • This is the first report from India on Networking for Biological Dosimetry preparedness using dicentric chromosomal (DC) aberration assay. • There is no significant difference in the in vitro dose response curve (Slope, Intercept, Curvature) constructed among the two labs. • No significant variation in the scoring of DC aberrations between the scorers irrespective of labs. • The DC results obtained by the labs from the Giemsa stained metaphase preparations were confirmed with centromere specific-FISH for further reliability and validity

  15. A Laboratory Exercise To Understand the Importance of Enzyme Technology in the Fruit-Processing Industry: Viscosity Decrease and Phenols Release from Apple Mash

    DEFF Research Database (Denmark)

    Pinelo, Manuel; Nielsen, Michael Krogsgaard; Meyer, Anne S.

    2011-01-01

    In a 4-h laboratory exercise, students accomplish a series of enzymatic macerations of apple mash, assess the viscosity of the mash during the maceration, extract the juice by centrifugation, and measure the levels of antioxidant phenols extracted into the juice after different enzyme treatments....

  16. IAEA interlaboratory exercise for water chemistry

    International Nuclear Information System (INIS)

    Joe, Kih Soo; Choi, Kwang Soon; Han, Sun Ho; Suh, Moo Yul; Jeon, Young Shin; Choi, Ke Chun; Kim, Yong Bok; Kim, Jong Gu; Kim, Won Ho

    2003-09-01

    KAERI Analytical laboratory participated in the IAEA Interlaboratory exercise for water chemistry of groundwater(RAS/8/084). 13 items such as pH, electroconductivity, HCO 3 , Cl, SO 4 , SiO 2 , B, Li, Na, K, Ca, Mg and NH 3 were analyzed. The result of this exercise showed that KAERI laboratory was ranked on the top level of the participants. Major analytical methods applied for this activity were ICP-AES, AAS, IC, pH meter, conductometer and acid titration

  17. ARN results in interlaboratory comparison exercises

    International Nuclear Information System (INIS)

    Equillor, Hugo; Lewis, Cecilia; Fernandez, Jorge; Canoba, Analia; Gavini, Ricardo; Grinman, Ana; Palacios, Miguel; Sartori, Francisco; Giustina, Daniel; Gnoni, Gabriela; Czerniczyniec, Mariela; Cialella, Hugo; Acosta, Soledad; Diodati, Jorge; Bonino, Nestor; Campos, Juan; Mondini, Julia; Franco, Graciela

    2008-01-01

    For years, the Nuclear Regulatory Authority (ARN) has been involved in several laboratory intercomparison programmes. The objective of participating in these exercises is to assure the quality of the determinations that the radiochemical laboratories of ARN carries out as part of its regulatory activity. Most of these determinations are related to its environmental monitoring program in the vicinity of nuclear and radioactive facilities existing in the country, in operation or not. Other determinations are related with effluent samples and monitoring activities performed inside the facilities. On the other hand, these intercomparisons are part of the requirements for the laboratories under ISO 17025. ARN laboratories are in process to obtain or maintain ISO 17025 accreditation as a priority objective. During the development of the intercomparisons, different samples have been tested in several matrices containing alpha, beta and gamma emitters. These exercises were organized by different laboratories as the IAEA, the EML and NIST from United States, the NPL and the NRPB from England, the BFS from Germany, and so on. The results were very satisfactory not only in direct measurements (gamma spectrometry) but also in those that require a previous intensive laboratory processing (alpha spectrometry and liquid scintillation), resulting in many cases better than the general average. This paper provides a summary of the results obtained in these exercises and the results are compared with the overall average of the participating laboratories. (author)

  18. Measurement of exercise habits and prediction of leisure-time activity in established exercise.

    Science.gov (United States)

    Tappe, Karyn A; Glanz, Karen

    2013-01-01

    Habit formation may be important to maintaining repetitive healthy behaviors like exercise. Existing habit questionnaires only measure part of the definition of habit (automaticity; frequency). A novel habit questionnaire was evaluated that measured contextual cueing. We designed a two-stage observational cohort study of regular exercisers. For stage 1, we conducted an in-person interview on a university campus. For stage 2, we conducted an internet-based survey. Participants were 156 adults exercising at least once per week. A novel measure, The Exercise Habit Survey (EHS) assessed contextual cueing through 13 questions on constancy of place, time, people, and exercise behaviors. A subset of the Self-Report Habit Index (SRHI), measuring automaticity, was also collected along with measures of intention and self-efficacy, and the International Physical Activity Questionnaire (IPAQ), leisure-time section. The EHS was evaluated using factor analysis and test-retest reliability. Its correlation to other exercise predictors and exercise behavior was evaluated using Pearson's r and hierarchical regression. Results suggested that the EHS comprised four subscales (People, Place, Time, Exercise Constancy). Only Exercise Constancy correlated significantly with SRHI. Only the People subscale predicted IPAQ exercise metabolic equivalents. The SRHI was a strong predictor. Contextual cueing is an important aspect of habit but measurement methodologies warrant refinement and comparison by different methods.

  19. Test-Retest Reliability of Rating of Perceived Exertion and Agreement With 1-Repetition Maximum in Adults.

    Science.gov (United States)

    Bove, Allyn M; Lynch, Andrew D; DePaul, Samantha M; Terhorst, Lauren; Irrgang, James J; Fitzgerald, G Kelley

    2016-09-01

    Study Design Clinical measurement. Background It has been suggested that rating of perceived exertion (RPE) may be a useful alternative to 1-repetition maximum (1RM) to determine proper resistance exercise dosage. However, the test-retest reliability of RPE for resistance exercise has not been determined. Additionally, prior research regarding the relationship between 1RM and RPE is conflicting. Objectives The purpose of this study was to (1) determine test-retest reliability of RPE related to resistance exercise and (2) assess agreement between percentages of 1RM and RPE during quadriceps resistance exercise. Methods A sample of participants with and without knee pathology completed a series of knee extension exercises and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale, then repeated the procedure 1 to 2 weeks later for test-retest reliability. To determine agreement between RPE and 1RM, participants completed knee extension exercises at various percentages of their 1RM (10% to 130% of predicted 1RM) and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale. Percent agreement was calculated between the 1RM and RPE at each resistance interval. Results The intraclass correlation coefficient indicated excellent test-retest reliability of RPE for quadriceps resistance exercises (intraclass correlation coefficient = 0.895; 95% confidence interval: 0.866, 0.918). Overall percent agreement between RPE and 1RM was 60%, but agreement was poor within the ranges that would typically be used for training (50% 1RM for muscle endurance, 70% 1RM and greater for strength). Conclusion Test-retest reliability of perceived exertion during quadriceps resistance exercise was excellent. However, agreement between the RPE and 1RM was poor, especially in common training zones for knee extensor strengthening. J Orthop Sports Phys Ther 2016;46(9):768-774. Epub 5 Aug 2016. doi:10.2519/jospt.2016.6498.

  20. PNNL Results from 2010 CALIBAN Criticality Accident Dosimeter Intercomparison Exercise

    International Nuclear Information System (INIS)

    Hill, Robin L.; Conrady, Matthew M.

    2011-01-01

    This document reports the results of the Hanford personnel nuclear accident dosimeter (PNAD) and fixed nuclear accident dosimeter (FNAD) during a criticality accident dosimeter intercomparison exercise at the CEA Valduc Center on September 20-23, 2010. Pacific Northwest National Laboratory (PNNL) participated in a criticality accident dosimeter intercomparison exercise at the Commissariat a Energie Atomique (CEA) Valduc Center near Dijon, France on September 20-23, 2010. The intercomparison exercise was funded by the U.S. Department of Energy, Nuclear Criticality Safety Program, with Lawrence Livermore National Laboratory as the lead Laboratory. PNNL was one of six invited DOE Laboratory participants. The other participating Laboratories were: Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Savannah River Site (SRS), the Y-12 National Security Complex at Oak Ridge, and Sandia National Laboratory (SNL). The goals of PNNL's participation in the intercomparison exercise were to test and validate the procedures and algorithm currently used for the Hanford personnel nuclear accident dosimeters (PNADs) on the metallic reactor, CALIBAN, to test exposures to PNADs from the side and from behind a phantom, and to test PNADs that were taken from a historical batch of Hanford PNADs that had varying degrees of degradation of the bare indium foil. Similar testing of the PNADs was done on the Valduc SILENE test reactor in 2009 (Hill and Conrady, 2010). The CALIBAN results are reported here.

  1. Laboratory Activity on Sample Handling and Maintaining a Laboratory Notebook through Simple pH Measurements

    Science.gov (United States)

    Erdmann, Mitzy A.; March, Joe L.

    2016-01-01

    Sample handling and laboratory notebook maintenance are necessary skills but can seem abstract if not presented to students in context. An introductory exercise focusing on proper sample handling, data collection and laboratory notebook keeping for the general chemistry laboratory was developed to emphasize the importance of keeping an accurate…

  2. Exercisers achieve greater acute exercise-induced mood enhancement than nonexercisers.

    Science.gov (United States)

    Hoffman, Martin D; Hoffman, Debi Rufi

    2008-02-01

    To determine whether a single session of exercise of appropriate intensity and duration for aerobic conditioning has a different acute effect on mood for nonexercisers than regular exercisers. Repeated-measures design. Research laboratory. Adult nonexercisers, moderate exercisers, and ultramarathon runners (8 men, 8 women in each group). Treadmill exercise at self-selected speeds to induce a rating of perceived exertion (RPE) of 13 (somewhat hard) for 20 minutes, preceded and followed by 5 minutes at an RPE of 9 (very light). Profile of Mood States before and 5 minutes after exercise. Vigor increased by a mean +/- standard deviation of 8+/-7 points (95% confidence interval [CI], 5-12) among the ultramarathon runners and 5+/-4 points (95% CI, 2-9) among the moderate exercisers, with no improvement among the nonexercisers. Fatigue decreased by 5+/-6 points (95% CI, 2-8) for the ultramarathon runners and 4+/-4 points (95% CI, 1-7) for the moderate exercisers, with no improvement among the nonexercisers. Postexercise total mood disturbance decreased by a mean of 21+/-16 points (95% CI, 12-29) among the ultramarathon runners, 16+/-10 points (95% CI, 7-24) among the moderate exercisers, and 9+/-13 points (95% CI, 1-18) among the nonexercisers. A single session of moderate aerobic exercise improves vigor and decreases fatigue among regular exercisers but causes no change in these scores for nonexercisers. Although total mood disturbance improves postexercise in exercisers and nonexercisers, regular exercisers have approximately twice the effect as nonexercisers. This limited postexercise mood improvement among nonexercisers may be an important deterrent for persistence with an exercise program.

  3. Feasibility of interactive biking exercise system for telemanagement in elderly.

    Science.gov (United States)

    Finkelstein, Joseph; Jeong, In Cheol

    2013-01-01

    Inexpensive cycling equipment is widely available for home exercise however its use is hampered by lack of tools supporting real-time monitoring of cycling exercise in elderly and coordination with a clinical care team. To address these barriers, we developed a low-cost mobile system aimed at facilitating safe and effective home-based cycling exercise. The system used a miniature wireless 3-axis accelerometer that transmitted the cycling acceleration data to a tablet PC that was integrated with a multi-component disease management system. An exercise dashboard was presented to a patient allowing real-time graphical visualization of exercise progress. The system was programmed to alert patients when exercise intensity exceeded the levels recommended by the patient care providers and to exchange information with a central server. The feasibility of the system was assessed by testing the accuracy of cycling speed monitoring and reliability of alerts generated by the system. Our results demonstrated high validity of the system both for upper and lower extremity exercise monitoring as well as reliable data transmission between home unit and central server.

  4. Reliability Engineering

    CERN Document Server

    Lazzaroni, Massimo

    2012-01-01

    This book gives a practical guide for designers and users in Information and Communication Technology context. In particular, in the first Section, the definition of the fundamental terms according to the international standards are given. Then, some theoretical concepts and reliability models are presented in Chapters 2 and 3: the aim is to evaluate performance for components and systems and reliability growth. Chapter 4, by introducing the laboratory tests, puts in evidence the reliability concept from the experimental point of view. In ICT context, the failure rate for a given system can be

  5. Student Attitudes towards Laboratory Exercises in Medical Biochemistry.

    Science.gov (United States)

    Cronholm, Tomas; Hoog, Jan-Olov; Martenson, Dick

    2000-01-01

    Examines student attitudes towards biochemical experiments and their effect on student learning. Finds that biochemical experiments in the medical curriculum are valuable, but efforts should be directed more towards the development of students' attitudes and approaches to the exercise. (Author/CCM)

  6. Accuracy of physical self-description among chronic exercisers and non-exercisers

    Directory of Open Access Journals (Sweden)

    Joseph M. Berning

    2014-10-01

    Full Text Available This study addressed the role of chronic exercise to enhance physical self-description as measured by self-estimated percent body fat. Accuracy of physical self-description was determined in normal-weight, regularly exercising and non-exercising males with similar body mass index (BMI’s and females with similar BMI’s (n=42 males and 45 females of which 23 males and 23 females met criteria to be considered chronic exercisers. Statistical analyses were conducted to determine the degree of agreement between self-estimated percent body fat and actual laboratory measurements (hydrostatic weighing. Three statistical techniques were employed: Pearson correlation coefficients, Bland and Altman plots, and regression analysis. Agreement between measured and self-estimated percent body fat was superior for males and females who exercised chronically, compared to non-exercisers. The clinical implications are as follows. Satisfaction with one’s body can be influenced by several factors, including self-perceived body composition. Dissatisfaction can contribute to maladaptive and destructive weight management behaviors. The present study suggests that regular exercise provides a basis for more positive weight management behaviors by enhancing the accuracy of self-assessed body composition.

  7. A laboratory-based evaluation of exercise plus contingency management for reducing cigarette smoking.

    Science.gov (United States)

    Kurti, Allison N; Dallery, Jesse

    2014-11-01

    Both contingency management (CM) and exercise have shown promise as smoking cessation treatments, but their combined effects have not been evaluated. The present study evaluated whether CM (in which motivational incentives are provided for abstinence) plus exercise reduced smoking more than either component alone. In a within-subjects design, 20 smokers were exposed to exercise plus CM, exercise plus CM-control (non-contingent incentives), inactivity plus CM, and inactivity plus CM-control. CM increased latencies to smoke and decreased total puffs (Mdns = 39.6 min and .8 puffs, respectively) relative to CM-control (Mdns = 2.5 min and 12.8 puffs). Exercise decreased craving relative to baseline for craving based on both the pleasurable consequences of smoking (D=-10.7 on a 100-point visual analog scale) and anticipated relief from withdrawal (D=-5.9), whereas inactivity increased both components of craving (Ds=7.6 and 3.5). Exercise had no effect on smoking or a measure of temporal discounting. Although exercise decreased craving, it did not affect smoking behavior. Exercise plus CM was not more effective than CM alone. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Changes in Exercise Data Management

    Science.gov (United States)

    Buxton, R. E.; Kalogera, K. L.; Hanson, A. M.

    2018-01-01

    The suite of exercise hardware aboard the International Space Station (ISS) generates an immense amount of data. The data collected from the treadmill, cycle ergometer, and resistance strength training hardware are basic exercise parameters (time, heart rate, speed, load, etc.). The raw data are post processed in the laboratory and more detailed parameters are calculated from each exercise data file. Updates have recently been made to how this valuable data are stored, adding an additional level of data security, increasing data accessibility, and resulting in overall increased efficiency of medical report delivery. Questions regarding exercise performance or how exercise may influence other variables of crew health frequently arise within the crew health care community. Inquiries over the health of the exercise hardware often need quick analysis and response to ensure the exercise system is operable on a continuous basis. Consolidating all of the exercise system data in a single repository enables a quick response to both the medical and engineering communities. A SQL server database is currently in use, and provides a secure location for all of the exercise data starting at ISS Expedition 1 - current day. The database has been structured to update derived metrics automatically, making analysis and reporting available within minutes of dropping the inflight data it into the database. Commercial tools were evaluated to help aggregate and visualize data from the SQL database. The Tableau software provides manageable interface, which has improved the laboratory's output time of crew reports by 67%. Expansion of the SQL database to be inclusive of additional medical requirement metrics, addition of 'app-like' tools for mobile visualization, and collaborative use (e.g. operational support teams, research groups, and International Partners) of the data system is currently being explored.

  9. Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test.

    Science.gov (United States)

    Hutchinson, Michael J; Paulson, Thomas A W; Eston, Roger; Goosey-Tolfrey, Victoria L

    2017-01-01

    To examine the reliability of a perceptually-regulated maximal exercise test (PRETmax) to measure peak oxygen uptake ([Formula: see text]) during handcycle exercise and to compare peak responses to those derived from a ramp-incremented protocol (RAMP). Twenty recreationally active individuals (14 male, 6 female) completed four trials across a 2-week period, using a randomised, counterbalanced design. Participants completed two RAMP protocols (20 W·min-1) in week 1, followed by two PRETmax in week 2, or vice versa. The PRETmax comprised five, 2-min stages clamped at Ratings of Perceived Exertion (RPE) 11, 13, 15, 17 and 20. Participants changed power output (PO) as often as required to maintain target RPE. Gas exchange variables (oxygen uptake, carbon dioxide production, minute ventilation), heart rate (HR) and PO were collected throughout. Differentiated RPE were collected at the end of each stage throughout trials. For relative [Formula: see text], coefficient of variation (CV) was equal to 4.1% and 4.8%, with ICC(3,1) of 0.92 and 0.85 for repeated measures from PRETmax and RAMP, respectively. Measurement error was 0.15 L·min-1 and 2.11 ml·kg-1·min-1 in PRETmax and 0.16 L·min-1 and 2.29 ml·kg-1·min-1 during RAMP for determining absolute and relative [Formula: see text], respectively. The difference in [Formula: see text] between PRETmax and RAMP was tending towards statistical significance (26.2 ± 5.1 versus 24.3 ± 4.0 ml·kg-1·min-1, P = 0.055). The 95% LoA were -1.9 ± 4.1 (-9.9 to 6.2) ml·kg-1·min-1. The PRETmax can be used as a reliable test to measure [Formula: see text] during handcycle exercise in recreationally active participants. Whilst PRETmax tended towards significantly greater [Formula: see text] values than RAMP, the difference is smaller than measurement error of determining [Formula: see text] from PRETmax and RAMP.

  10. A Concentrated Teaching Exercise for Introducing Clinical Dermatology

    Science.gov (United States)

    Binford, Robert T.; And Others

    1973-01-01

    At Cornell University Medical College one 3-hour session in dermatology is required during the second year. A teaching exercise has been developed that combines a lecture, laboratory exercises, and presentations of patients. (Author)

  11. Reliability Analysis of Traditional and Ballistic Bench Press Exercises at Different Loads.

    Science.gov (United States)

    García-Ramos, Amador; Padial, Paulino; García-Ramos, Miguel; Conde-Pipó, Javier; Argüelles-Cienfuegos, Javier; Štirn, Igor; Feriche, Belén

    2015-09-29

    The purpose of this study was to determine test-retest reliability for peak barbell velocity (Vpeak) during the bench press (BP) and bench press throw (BPT) exercises for loads corresponding to 20-70% of one-repetition maximum (1RM). Thirty physically active collegiate men conducted four evaluations after a preliminary BP 1RM determination (1RM·bw-1 = 1.02 ± 0.16 kg·kg-1). In counterbalanced order, participants performed two sessions of the BP in one week and two sessions of the BPT in another week. Recovery time between sessions within the same week was 48 hours and recovery time between sessions of different weeks was 120 hours. On each day of evaluation the individual load-velocity relationship at each tenth percentile (20-70% of 1RM) in a Smith machine for the BP or BPT was determined. Participants performed three attempts per load, but only the best repetition (highest Vpeak), registered by a linear position transducer, was analysed. The BPT resulted in a significantly lower coefficient of variation (CV) for the whole load-velocity relationship, compared to the BP (2.48% vs. 3.22%; p = 0.040). Test-retest intraclass correlation coefficients (ICCs) ranged from r = 0.94-0.85 for the BPT and r = 0.91-0.71 for the BP (p velocity.

  12. Results Assessment of Intercomparison Exercise CSN/CIEMAT-2012 among Spanish National Laboratories of Environmental Radioactivity (Soil); Evaluación de la Intercomparación CSN/CIEMAT-2012 entre los Laboratorios Nacionales de Radiactividad Ambiental (Suelo)

    Energy Technology Data Exchange (ETDEWEB)

    Trinidad, J. A.; Gascó, C.; Llauradó, M.

    2015-07-01

    This report describes the results assessment of the intercomparsion exercise among environmental radioactivity laboratories, organised by Spanish Regulatory Institution (CSN) and prepared and evaluated by UB and CIEMAT respectively. The exercise has been carried out following the international standards ISO-43 and ISO/IUPAC that provide a useful guide to perform proficiency tests and inter-laboratories comparisons. The selected matrix for this year (2012) was soil, that was enriched with artificial radionuclides (137Cs, 60Co, 55Fe, 63Ni, 90Sr, 241Am, 239+240Pu and 238Pu) and contained natural radionuclides (234U, 238U, U-natural 230Th, 226Ra, 210Pb, 228Ra, 228Ac, 234Th, 214Bi, 214Pb, 212Pb, 208Tl and 40K) at environmental level of activity concentration. Two soil matrixes were prepared in order to separate 55Fe and 63Ni analysis. The z-score test was applied to determine how much the laboratories differ from the reference value. The reference value for this exercise was the median of the results from the different laboratories and their standard deviations to achieve a more complete and objective study of the laboratories performance. The participant laboratories have demonstrated a satisfactory quality level for measuring the natural and artificial radionuclides content in this matrix. The study has showed a homogeneous behaviour of the laboratories.

  13. Teaching acid/base physiology in the laboratory

    DEFF Research Database (Denmark)

    Friis, Ulla G; Plovsing, Ronni; Hansen, Klaus

    2010-01-01

    exercise in acid/base physiology that would provide students with unambiguous and reproducible data that clearly would illustrate the theory in practice. The laboratory exercise was developed to include both metabolic acidosis and respiratory alkalosis. Data were collected from 56 groups of medical...... students that had participated in this laboratory exercise. The acquired data showed very consistent and solid findings after the development of both metabolic acidosis and respiratory alkalosis. All results were consistent with the appropriate diagnosis of the acid/base disorder. Not one single group...... failed to obtain data that were compatible with the diagnosis; it was only the degree of acidosis/alkalosis and compensation that varied....

  14. Leg Stiffness in Female Soccer Players: Intersession Reliability and the Fatiguing Effects of Soccer-Specific Exercise.

    Science.gov (United States)

    De Ste Croix, Mark B A; Hughes, Jonathan D; Lloyd, Rhodri S; Oliver, Jon L; Read, Paul J

    2017-11-01

    De Ste Croix, MBA, Hughes, JD, Lloyd, RS, Oliver, JL, and Read, PJ. Leg stiffness in female soccer players: intersession reliability and the fatiguing effects of soccer-specific exercise. J Strength Cond Res 31(11): 3052-3058, 2016-Low levels of leg stiffness and reduced leg stiffness when fatigue is present compromise physical performance and increase injury risk. The purpose of this study was to (a) determine the reliability of leg stiffness measures obtained from contact mat data and (b) explore age-related differences in leg stiffness after exposure to a soccer-specific fatigue protocol in young female soccer players. Thirty-seven uninjured female youth soccer players divided into 3 subgroups based on chronological age (under 13 [U13], under 15 [U15], and under 17 [U17] year-olds) volunteered to participate in the study. After baseline data collection, during which relative leg stiffness, contact time, and flight time were collected, participants completed an age-appropriate soccer-specific fatigue protocol (SAFT). Upon completion of the fatigue protocol, subjects were immediately retested. Intersession reliability was acceptable and could be considered capable of detecting worthwhile changes in performance. Results showed that leg stiffness decreased in the U13 year-olds, was maintained in the U15 age group, and increased in the U17 players. Contact times and flight times did not change in the U13 and U15 year-olds, but significantly decreased and increased, respectively, in the U17 age group. The data suggest that age-related changes in the neuromuscular control of leg stiffness are present in youth female soccer players. Practitioners should be aware of these discrepancies in neuromuscular responses to soccer-specific fatigue, and should tailor training programs to meet the needs of individuals, which may subsequently enhance performance and reduce injury risk.

  15. Cross-Cultural and Psychometric Properties Assessment of the Exercise Self-Efficacy Scale in Individuals with Spinal Cord Injury.

    Science.gov (United States)

    Pisconti, Fernando; Mahmoud Smaili Santos, Suhaila; Lopes, Josiane; Rosa Cardoso, Jefferson; Lopes Lavado, Edson

    2017-11-29

    The Exercise Self-Efficacy scale (ESES) is a reliable measure, in the English language, of exercise self-efficacy in individuals with spinal cord injury. The aim of this study was to culturally adjust and validate the Exercise Self-Efficacy scale in the Portuguese language. The Exercise Self-Efficacy scale was applied to 76 subjects, with three-month intervals (three applications in total). The reliability was appraised using the intra-class correlation coefficient and Bland-Altman methods, and the internal consistency was evaluated using Cronbach´s alpha. The Exercise Self-Efficacy scale was correlated with the domains of the Quality of life Questionnaire SF-36 and Functional Independence Measure and tested using the Spearman rho coefficient. The Exercise Self-Efficacy scale-Brazil presented good internal consistency (alpha 1 = 0.856; alpha 2 = 0.855; alpha 3 = 0.822) and high reliability in the test-retest (intra-class correlation coefficient = 0.97). There was a strong correlation between the Exercise Self-Efficacy scale-Brazil and the SF-36 only in the functional capacity domain (rho = 0.708). There were no changes in Exercise Self-Efficacy scale-Brazil scores between the three applications (p = 0.796). The validation of the Exercise Self-Efficacy scale questionnaire permits the assessor to use it reliably in Portuguese speaking countries, since it is the first instrument measuring self-efficacy specifically during exercises in individuals with spinal cord injury. Furthermore, the questionnaire can be used as an instrument to verify the effectiveness of interventions that use exercise as an outcome. The results of the Brazilian version of the Exercise Self-Efficacy scale support its use as a reliable and valid measurement of exercise self-efficacy for this population.

  16. Influence of Self-Efficacy on Compliance to Workplace Exercise

    DEFF Research Database (Denmark)

    Pedersen, Mette Merete; Zebis, Mette K; Jørgensen, Henning Langberg

    2013-01-01

    the influence of exercise-specific self-efficacy on compliance to workplace physical exercise. PURPOSE: To determine the influence of exercise-specific self-efficacy on compliance to specific strength exercises during working hours for laboratory technicians. METHODS: We performed a cluster...... of compliance to exercises during 20 weeks, but found self-efficacy to be a predictor of compliance in a private sector setting. Workplace-specific differences might be present and should be taken into account....

  17. Grimsel colloid exercise, an international intercomparison exercise on the sampling and characterization of groundwater colloids

    International Nuclear Information System (INIS)

    Degueldre, C.

    1990-01-01

    The Grimsel colloid exercise was an intercomparison exercise which consisted of an in situ sampling phase followed by a colloid characterization step. The goal of this benchmark exercise, which involved 12 laboratories, was to evaluate both sampling and characterization techniques with emphasis on the colloid specific size distribution. The sampling phase took place at the Grimsel test site between 1 and 13 February 1988 and the participating groups produced colloid samples using various methods. This work was carried out within the Community COCO Club, as a component of the Mirage project (second phase)

  18. Concentric and eccentric time-under-tension during strengthening exercises: Validity and reliability of stretch-sensor recordings from an elastic exercise-band

    DEFF Research Database (Denmark)

    Rathleff, Michael Skovdal; Thorborg, Kristian; Bandholm, Thomas Quaade

    2013-01-01

    Total, single repetition and contraction-phase specific (concentric and eccentric) time-under-tension (TUT) are important exercise-descriptors, as they are linked to the physiological and clinical response in exercise and rehabilitation....

  19. Psychometric examination and factorial validity of the Exercise Dependence Scale-Revised in Italian exercisers.

    Science.gov (United States)

    Costa, Sebastiano; Cuzzocrea, Francesca; Hausenblas, Heather A; Larcan, Rosalba; Oliva, Patrizia

    2012-12-01

    Background and aims The purpose of this study was to verify the factorial structure, internal validity, reliability, and criterion validity of the 21-item Exercise Dependence Scale-Revised (EDS-R) in an Italian sample. Methods Italian voluntary (N = 519) users of gyms who had a history of regular exercise for over a year completed the EDS-R and measures of exercise frequency. Results and conclusions Confirmatory factor analyses demonstrated a good fit to the hypothesized 7-factor model, and adequate internal consistency for the scale was evidenced. Criterion validity was evidenced by significant correlations among all the subscale of the EDS and exercise frequency. Finally, individuals at risk for exercise dependence reported more exercise behavior compared to the nondependent-symptomatic and nondependent-asymptomatic groups. These results suggest that the seven subscales of the Italian version of the EDS are measuring the construct of exercise dependence as defined by the DSM-IV criteria for substance dependence and also confirm previous research using the EDS-R in other languages. More research is needed to examine the psychometric properties of the EDS-R in diverse populations with various research designs.

  20. Virtual Exercise Training Software System

    Science.gov (United States)

    Vu, L.; Kim, H.; Benson, E.; Amonette, W. E.; Barrera, J.; Perera, J.; Rajulu, S.; Hanson, A.

    2018-01-01

    The purpose of this study was to develop and evaluate a virtual exercise training software system (VETSS) capable of providing real-time instruction and exercise feedback during exploration missions. A resistive exercise instructional system was developed using a Microsoft Kinect depth-camera device, which provides markerless 3-D whole-body motion capture at a small form factor and minimal setup effort. It was hypothesized that subjects using the newly developed instructional software tool would perform the deadlift exercise with more optimal kinematics and consistent technique than those without the instructional software. Following a comprehensive evaluation in the laboratory, the system was deployed for testing and refinement in the NASA Extreme Environment Mission Operations (NEEMO) analog.

  1. Reliability in the location of hindlimb motor representations in Fischer-344 rats: laboratory investigation.

    Science.gov (United States)

    Frost, Shawn B; Iliakova, Maria; Dunham, Caleb; Barbay, Scott; Arnold, Paul; Nudo, Randolph J

    2013-08-01

    The purpose of the present study was to determine the feasibility of using a common laboratory rat strain for reliably locating cortical motor representations of the hindlimb. Intracortical microstimulation techniques were used to derive detailed maps of the hindlimb motor representations in 6 adult Fischer-344 rats. The organization of the hindlimb movement representation, while variable across individual rats in topographic detail, displayed several commonalities. The hindlimb representation was positioned posterior to the forelimb motor representation and posterolateral to the motor trunk representation. The areal extent of the hindlimb representation across the cortical surface averaged 2.00 ± 0.50 mm(2). Superimposing individual maps revealed an overlapping area measuring 0.35 mm(2), indicating that the location of the hindlimb representation can be predicted reliably based on stereotactic coordinates. Across the sample of rats, the hindlimb representation was found 1.25-3.75 mm posterior to the bregma, with an average center location approximately 2.6 mm posterior to the bregma. Likewise, the hindlimb representation was found 1-3.25 mm lateral to the midline, with an average center location approximately 2 mm lateral to the midline. The location of the cortical hindlimb motor representation in Fischer-344 rats can be reliably located based on its stereotactic position posterior to the bregma and lateral to the longitudinal skull suture at midline. The ability to accurately predict the cortical localization of functional hindlimb territories in a rodent model is important, as such animal models are being increasingly used in the development of brain-computer interfaces for restoration of function after spinal cord injury.

  2. Facial feature tracking: a psychophysiological measure to assess exercise intensity?

    Science.gov (United States)

    Miles, Kathleen H; Clark, Bradley; Périard, Julien D; Goecke, Roland; Thompson, Kevin G

    2018-04-01

    The primary aim of this study was to determine whether facial feature tracking reliably measures changes in facial movement across varying exercise intensities. Fifteen cyclists completed three, incremental intensity, cycling trials to exhaustion while their faces were recorded with video cameras. Facial feature tracking was found to be a moderately reliable measure of facial movement during incremental intensity cycling (intra-class correlation coefficient = 0.65-0.68). Facial movement (whole face (WF), upper face (UF), lower face (LF) and head movement (HM)) increased with exercise intensity, from lactate threshold one (LT1) until attainment of maximal aerobic power (MAP) (WF 3464 ± 3364mm, P exercise intensities (UF minus LF at: LT1, 1048 ± 383mm; LT2, 1208 ± 611mm; MAP, 1401 ± 712mm; P exercise intensity.

  3. Improving the Reliability of Tinnitus Screening in Laboratory Animals.

    Science.gov (United States)

    Jones, Aikeen; May, Bradford J

    2017-02-01

    Behavioral screening remains a contentious issue for animal studies of tinnitus. Most paradigms base a positive tinnitus test on an animal's natural tendency to respond to the "sound" of tinnitus as if it were an actual sound. As a result, animals with tinnitus are expected to display sound-conditioned behaviors when no sound is present or to miss gaps in background sounds because tinnitus "fills in the gap." Reliable confirmation of the behavioral indications of tinnitus can be problematic because the reinforcement contingencies of conventional discrimination tasks break down an animal's tendency to group tinnitus with sound. When responses in silence are rewarded, animals respond in silence regardless of their tinnitus status. When responses in silence are punished, animals stop responding. This study introduces stimulus classification as an alternative approach to tinnitus screening. Classification procedures train animals to respond to the common perceptual features that define a group of sounds (e.g., high pitch or narrow bandwidth). Our procedure trains animals to drink when they hear tinnitus and to suppress drinking when they hear other sounds. Animals with tinnitus are revealed by their tendency to drink in the presence of unreinforced probe sounds that share the perceptual features of the tinnitus classification. The advantages of this approach are illustrated by taking laboratory rats through a testing sequence that includes classification training, the experimental induction of tinnitus, and postinduction screening. Behavioral indications of tinnitus are interpreted and then verified by simulating a known tinnitus percept with objective sounds.

  4. Reliability Analysis of Money Habitudes

    Science.gov (United States)

    Delgadillo, Lucy M.; Bushman, Brittani S.

    2015-01-01

    Use of the Money Habitudes exercise has gained popularity among various financial professionals. This article reports on the reliability of this resource. A survey administered to young adults at a western state university was conducted, and each Habitude or "domain" was analyzed using Cronbach's alpha procedures. Results showed all six…

  5. Results Assessment of Intercomparison Exercise CSN/CIEMAT-2010 among Spanish National Laboratories of Environmental Radioactivity (Diet Ashes); Evaluacion de la Intercomparacion CSN/CIEMAT-2010 entre los Laboratorios Nacionales de Radiactividad Ambiental (Ceniza de Dieta)

    Energy Technology Data Exchange (ETDEWEB)

    Gasco, C.; Trinidad, J. A.; Llaurado, M.; Suarez, J. A.

    2012-06-08

    This report describes the results assessment of the intercomparison exercise among environmental radioactivity laboratories, organised by Spanish Regulatory Institution (CSN) and prepared and evaluated by UAB and CIEMAT respectively. The exercise has been carried out following the international standards ISO-43 and ISO/IUPAC that provide a useful guide to perform proficiency tests and inter-laboratories comparisons. The selected matrix for this year (2010) was a diet ash obtained from the ashing of a whole fresh diet (breakfast, lunch and dinner), that was enriched with artificial radionuclides (Cs-137, Co-60,Fe-55,Ni-63,Sr-90,Am-241,Pu-238,Pu-239,240 y C-14) and contained natural radionuclides (U-234, U-238, U-natural Th-230, Th-234, Ra-226, Ra-228, Pb-210, Pb-212, Pb-214, Bi-214, Ac-228, Tl-208, K-40) at environmental level of activity concentration. The z-score test was applied to determine how much the laboratories differ from the reference value. The reference value for this exercise was the median of the results from the different laboratories and their standard deviations to achieve a more complete and objective study of the laboratories performance. The participant laboratories have demonstrated a satisfactory quality level for measuring the natural and artificial radionuclides content in this matrix. The reference values obtained through the medians show a negative bias for Pb-210 and Th-234 when comparing to the given values of external qualified laboratories from ENEA and IRSN and positive one for K-40. (Author)

  6. Astronomy Exercises for the Artist: van Gogh the Observer

    Science.gov (United States)

    Lawlor, Timothy M.

    2013-01-01

    We present a set of exercises designed to be used in a survey astronomy course, an introductory astronomy laboratory course, or in secondary education. The exercises use the great works of Vincent van Gogh but could

  7. Validity and reliability of a novel iPhone app for the measurement of barbell velocity and 1RM on the bench-press exercise.

    Science.gov (United States)

    Balsalobre-Fernández, Carlos; Marchante, David; Muñoz-López, Mario; Jiménez, Sergio L

    2018-01-01

    The purpose of this study was to analyse the validity and reliability of a novel iPhone app (named: PowerLift) for the measurement of mean velocity on the bench-press exercise. Additionally, the accuracy of the estimation of the 1-Repetition maximum (1RM) using the load-velocity relationship was tested. To do this, 10 powerlifters (Mean (SD): age = 26.5 ± 6.5 years; bench press 1RM · kg -1  = 1.34 ± 0.25) completed an incremental test on the bench-press exercise with 5 different loads (75-100% 1RM), while the mean velocity of the barbell was registered using a linear transducer (LT) and Powerlift. Results showed a very high correlation between the LT and the app (r = 0.94, SEE = 0.028 m · s -1 ) for the measurement of mean velocity. Bland-Altman plots (R 2  = 0.011) and intraclass correlation coefficient (ICC = 0.965) revealed a very high agreement between both devices. A systematic bias by which the app registered slightly higher values than the LT (P velocity in the bench-press exercise.

  8. Power Electronics Packaging Reliability | Transportation Research | NREL

    Science.gov (United States)

    Packaging Reliability Power Electronics Packaging Reliability A photo of a piece of power electronics laboratory equipment. NREL power electronics packaging reliability research investigates the electronics packaging around a semiconductor switching device determines the electrical, thermal, and

  9. Influence of self-efficacy on compliance to workplace exercise.

    Science.gov (United States)

    Pedersen, Mette Merete; Zebis, Mette Kreutzfeldt; Langberg, Henning; Poulsen, Otto Melchior; Mortensen, Ole Steen; Jensen, Jette Nygaard; Sjøgaard, Gisela; Bredahl, Thomas; Andersen, Lars Louis

    2013-09-01

    Continuous neck and shoulder pain is a common musculoskeletal complaint. Physical exercise can reduce pain symptoms, but compliance to exercise is a challenge. Exercise-specific self-efficacy has been found to be a predictor of participation in preplanned exercise. Little is known about the influence of exercise-specific self-efficacy on compliance to workplace physical exercise. To determine the influence of exercise-specific self-efficacy on compliance to specific strength exercises during working hours for laboratory technicians. We performed a cluster-randomized controlled trial, including laboratory technicians from two industrial production units in Copenhagen, Denmark. The participants were randomized to supervised specific strength exercises for the neck and shoulder muscles for 20 minutes three times a week (n = 282) or to a reference group (n = 255). The participants answered baseline and follow-up questions regarding self-efficacy and registered all exercises in a diary. Overall compliance to exercises was 45 %. Compliance in company A (private sector) differed significantly between the three self-efficacy groups after 20 weeks. The odds ratio of compliance was 2.37 for moderate versus low self-efficacy, and 2.93 for high versus low self-efficacy. No significant difference was found in company B (public sector) or in the intervention group as a whole. We did not find self-efficacy to be a general statistically significant predictor of compliance to exercises during 20 weeks, but found self-efficacy to be a predictor of compliance in a private sector setting. Workplace-specific differences might be present and should be taken into account.

  10. Muscle receptor organs in the crayfish abdomen: a student laboratory exercise in proprioception.

    Science.gov (United States)

    Leksrisawat, Bonnie; Cooper, Ann S; Gilberts, Allison B; Cooper, Robin L

    2010-11-18

    The primary purpose of this experiment is to demonstrate primary sensory neurons conveying information of joint movements and positions as proprioceptive information for an animal. An additional objective of this experiment is to learn anatomy of the preparation by staining, dissection and viewing of neurons and sensory structures under a dissecting microscope. This is performed by using basic neurophysiological equipment to record the electrical activity from a joint receptor organ and staining techniques. The muscle receptor organ (MRO) system in the crayfish is analogous to the intrafusal muscle spindle in mammals, which aids in serving as a comparative model that is more readily accessible for electrophysiological recordings. In addition, these are identifiable sensory neurons among preparations. The preparation is viable in a minimal saline for hours which is amenable for student laboratory exercises. The MRO is also susceptible to neuromodulation which encourages intriguing questions in the sites of modulatory action and integration of dynamic signals of movements and static position along with a gain that can be changed in the system.

  11. A New Measure of Home Exercise Benefits and Barriers

    Science.gov (United States)

    Thind, Herpreet; Fava, Joseph; Traficante, Regina; Bock, Beth C.

    2016-01-01

    Background: To increase physical activity among college students, new approaches are needed including the exploration of home-based exercise. However, research related to potential facilitators and barriers to exercising at home is limited. Purpose: The goal of this study was to develop a reliable and valid measure that can assess predictors of…

  12. Computer-based nuclear radiation detection and instrumentation teaching laboratory system

    International Nuclear Information System (INIS)

    Ellis, W.H.; He, Q.

    1993-01-01

    The integration of computers into the University of Florida's Nuclear Engineering Sciences teaching laboratories is based on the innovative use of MacIntosh 2 microcomputers, IEEE-488 (GPIB) communication and control bus system and protocol, compatible modular nuclear instrumentation (NIM) and test equipment, LabVIEW graphics and applications software, with locally prepared, interactive, menu-driven, HyperCard based multi-exercise laboratory instruction sets and procedures. Results thus far have been highly successful with the majority of the laboratory exercises having been implemented

  13. State of laboratory manual instruction in California community college introductory (non-majors) biology laboratory instruction

    Science.gov (United States)

    Priest, Michelle

    College students must complete a life science course prior to graduation for a bachelor's degree. Generally, the course has lecture and laboratory components. It is in the laboratory where there are exceptional opportunities for exploration, challenge and application of the material learned. Optimally, this would utilize the best of inquiry based approaches. Most community colleges are using a home-grown or self written laboratory manual for the direction of work in the laboratory period. Little was known about the motivation, development and adaptation of use. It was also not known about the future of the laboratory manuals in light of the recent learning reform in California Community Colleges, Student Learning Outcomes. Extensive interviews were conducted with laboratory manual authors to determine the motivation, process of development, who was involved and learning framework used in the creation of the manuals. It was further asked of manual authors their ideas about the future of the manual, the development of staff and faculty and finally, the role Student Learning Outcomes would play in the manual. Science faculty currently teaching the non-majors biology laboratories for at least two semesters were surveyed on-line about actual practice of the manual, assessment, manual flexibility, faculty training and incorporation of Student Learning Outcomes. Finally, an evaluation of the laboratory manual was done using an established Laboratory Task Analysis Instrument. Laboratory manuals were evaluated on a variety of categories to determine the level of inquiry instruction done by students in the laboratory section. The results were that the development of homegrown laboratory manuals was done by community colleges in the Los Angeles and Orange Counties in an effort to minimize the cost of the manual to the students, to utilize all the exercises in a particular lab and to effectively utilize the materials already owned by the department. Further, schools wanted to

  14. Influence of Self-Efficacy on Compliance to Workplace Exercise

    DEFF Research Database (Denmark)

    Pedersen, Mette Merete; Zebis, Mette Kreutzfeldt; Langberg, Henning

    2013-01-01

    BACKGROUND: Continuous neck and shoulder pain is a common musculoskeletal complaint. Physical exercise can reduce pain symptoms, but compliance to exercise is a challenge. Exercise-specific self-efficacy has been found to be a predictor of participation in preplanned exercise. Little is known about...... the influence of exercise-specific self-efficacy on compliance to workplace physical exercise. PURPOSE: To determine the influence of exercise-specific self-efficacy on compliance to specific strength exercises during working hours for laboratory technicians. METHODS: We performed a cluster......). The participants answered baseline and follow-up questions regarding self-efficacy and registered all exercises in a diary. RESULTS: Overall compliance to exercises was 45 %. Compliance in company A (private sector) differed significantly between the three self-efficacy groups after 20 weeks. The odds ratio...

  15. Final Report to the National Energy Technology Laboratory on FY09-FY13 Cooperative Research with the Consortium for Electric Reliability Technology Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Vittal, Vijay [Arizona State Univ., Mesa, AZ (United States)

    2015-11-04

    The Consortium for Electric Reliability Technology Solutions (CERTS) was formed in 1999 in response to a call from U.S. Congress to restart a federal transmission reliability R&D program to address concerns about the reliability of the U.S. electric power grid. CERTS is a partnership between industry, universities, national laboratories, and government agencies. It researches, develops, and disseminates new methods, tools, and technologies to protect and enhance the reliability of the U.S. electric power system and the efficiency of competitive electricity markets. It is funded by the U.S. Department of Energy’s Office of Electricity Delivery and Energy Reliability (OE). This report provides an overview of PSERC and CERTS, of the overall objectives and scope of the research, a summary of the major research accomplishments, highlights of the work done under the various elements of the NETL cooperative agreement, and brief reports written by the PSERC researchers on their accomplishments, including research results, publications, and software tools.

  16. Domain dependent associations between cognitive functioning and regular voluntary exercise behavior

    NARCIS (Netherlands)

    Swagerman, S.C.; de Geus, E.J.C.; Koenis, M.M.G.; Hulshoff Pol, H.E.; Boomsma, D.I.; Kan, K.J.

    2015-01-01

    Regular exercise has often been suggested to have beneficial effects on cognition, but empirical findings are mixed because of heterogeneity in sample composition (age and sex); the cognitive domain being investigated; the definition and reliability of exercise behavior measures; and study design

  17. Domain dependent associations between cognitive functioning and regular voluntary exercise behavior

    NARCIS (Netherlands)

    Swagerman, Suzanne C; de Geus, Eco J C; Koenis, Marinka M G; Hulshoff Pol, Hilleke E; Boomsma, Dorret I; Kan, Kees-Jan

    Regular exercise has often been suggested to have beneficial effects on cognition, but empirical findings are mixed because of heterogeneity in sample composition (age and sex); the cognitive domain being investigated; the definition and reliability of exercise behavior measures; and study design

  18. A LabVIEW based Remote DSP Laboratory

    Directory of Open Access Journals (Sweden)

    Athanasios Kalantzopoulos

    2008-07-01

    Full Text Available Remote laboratories provide the students with the capability to perform laboratory exercises exploiting the relevant equipment any time of the day without their physical presence. Furthermore, providing the ability to use a single workstation by more than one student, they contribute to the reduction of the laboratory cost. Turning to advantage the above and according to the needs of post graduate modules in the fields of DSP Systems Design and Signal Processing Systems with DSPs, we designed and developed a Remote DSP Laboratory. A student using a Web Browser has the ability via internet to turn to account the R-DSP Lab and perform experiments using DSPs (Digital Signal Processors. For now, there is the opportunity to carry out laboratory exercises such as FIR, IIR digital filters and FFT as well as run any executable file developed by the user. In any case the observation of the results is carried out through the use of specially designed Graphical User Interfaces (GUIs.

  19. Lessons learned during the training exercise for the entry into force of the U.S. additional protocol in the DOE complex

    Energy Technology Data Exchange (ETDEWEB)

    Boyer, Brian D [Los Alamos National Laboratory

    2009-01-01

    In 2008 in anticipation of the United States bringing into force the Additional Protocol in early 2009 DOE/NNSA planned and executed training exercises in the conduct of Additional Protocol complementary access activities. Brookhaven National Laboratory and Los Alamos National Laboratory together produced the exercises designed to prepare the following types of DOE laboratories for complementary access - weapons laboratories, nuclear engineering laboratories, and science laboratories. This panel provides a forum to discuss and summarize the results and lessons learned from the 2008 exercise.

  20. Reliability of different methods used for forming of working samples in the laboratory for seed testing

    Directory of Open Access Journals (Sweden)

    Opra Branislava

    2000-01-01

    Full Text Available The testing of seed quality starts from the moment a sample is formed in a warehouse during processing or packaging of the seed. The seed sampling as the process of obtaining the working sample also assumes each step undertaken during its testing in the laboratory. With the aim of appropriate forming of a seed sample in the laboratory, the usage of seed divider is prescribed for large seeded species (such as seed the size of wheat or larger (ISTA Rules, 1999. The aim of this paper was the comparison of different methods used for obtaining the working samples of maize and wheat seeds using conical, soil and centrifugal dividers. The number of seed of added admixtures confirmed the reliability of working samples formation. To each maize sample (1000 g 10 seeds of the following admixtures were added: Zea mays L. (red pericarp, Hordeum vulgäre L., Triticum aestivum L., and Glycine max (L. Merr. Two methods were used for formation of maze seed working sample. To wheat samples (1000 g 10 seeds of each of the following species were added: Avena saliva (hulled seeds, Hordeum vulgäre L., Galium tricorne Stokes, and Polygonum lapatifolmm L. For formation of wheat seed working samples four methods were used. Optimum of 9, but not less than 7 seeds of admixture were due to be determined in the maize seed working sample, while for wheat, at least one seed of admixture was expected to be found in the working sample. The obtained results confirmed that the formation of the maize seed working samples was the most reliable when centrifugal divider, the first method was used (average of admixture - 9.37. From the observed admixtures the seed of Triticum aestivum L. was the most uniformly distributed, the first method also being used (6.93. The second method gains high average values satisfying the given criterion, but it should be used with previous homogenization of the sample being tested. The forming of wheat seed working samples is the most reliable if the

  1. Development and validation of an exercise performance support system for people with lower extremity impairment.

    Science.gov (United States)

    Minor, M A; Reid, J C; Griffin, J Z; Pittman, C B; Patrick, T B; Cutts, J H

    1998-02-01

    To identify innovative strategies to support appropriate, self-directed exercise that increase physical activity levels of people with arthritis. This article reports on one interactive, multimedia exercise performance support system (PSS) for people with lower extremity impairments in strength or flexibility. An interdisciplinary team developed the PSS using self-report of lower extremity musculoskeletal impairments (flexibility and strength) to produce an individualized exercise program with video and print educational materials. Initial evaluation has investigated the validity and reliability of program assessments and recommendations. PSS self-report and professional assessments were similar, with more impairments indicated by self-report. PSS exercise recommendations were similar to those made by 3 expert physical therapists using the same exercise data base. Results of PSS impairment assessments were stable over a 1-week period. PSS exercise recommendations appear to be reliable and a valid reflection of current exercise knowledge in rheumatology. Furthermore, users were able to complete the computer-based program with minimal assistance and reported it to be enjoyable and informative.

  2. Reliability and accuracy of Cooper's test in male long distance runners

    Directory of Open Access Journals (Sweden)

    J.R. Alvero-Cruz

    2017-06-01

    Conclusions: All together, our results may confirm a good accuracy and reliability of Cooper's test in amateur long distance runners. Also, improvements or impairment lower than 52.2 m must not be associated with exercise training or retraining, since they are below the values of intra-subject reliability.

  3. Psychometric properties of the Exercise Benefits/Barriers Scale in Mexican elderly women

    Directory of Open Access Journals (Sweden)

    María Cristina Enríquez-Reyna

    Full Text Available ABSTRACT Objective: analyze and assess the psychometric properties of the subscales in the Spanish version of the Exercise Benefits/Barriers Scale in an elderly population in the Northeast of Mexico. Method: methodological study. The sample consisted of 329 elderly associated with one of the five public centers for senior citizens in the metropolitan area of Northeast Mexico. The psychometric properties included the assessment of the Cronbach's alpha coefficient, the Kaiser Meyer Olkin coefficient, the inter-item correlation, exploratory and confirmatory factor analysis. Results: in the principal components analysis, two components were identified based on the 43 items in the scale. The item-total correlation coefficient of the exercise benefits subscale was good. Nevertheless, the coefficient for the exercise barriers subscale revealed inconsistencies. The reliability and validity were acceptable. The confirmatory factor analysis revealed that the elimination of items improved the goodness of fit of the baseline scale, without affecting its validity or reliability. Conclusion: the Exercise Benefits/Barriers subscale presented satisfactory psychometric properties for the Mexican context. A 15-item short version is presented with factorial structure, validity and reliability similar to the complete scale.

  4. Computed exercise plasma lactate concentrations: A conversion formula

    Directory of Open Access Journals (Sweden)

    Lia Bally

    2016-04-01

    Full Text Available Objectives: Blood lactate measurements are common as a marker of skeletal muscle metabolism in sport medicine. Due to the close equilibrium between the extracellular and intramyocellular space, plasma lactate is a more accurate estimate of muscle lactate. However, whole blood-based lactate measurements are more convenient in field use. The purpose of this investigation was therefore (1 to establish a plasma-converting lactate formula for field use, and (2 to validate the computed plasma lactate levels by comparison to a laboratory standard method. Design and methods: A total of 91 venous samples were taken from 6 individuals with type 1 diabetes during resting and exercise conditions and assessed for whole blood and plasma lactate using the YSI 2300 analyzer. A linear model was applied to establish a formula for converting whole blood lactate to plasma lactate. The validity of computed plasma lactate values was assessed by comparison to a laboratory standard method. Results: Whole blood YSI lactate could be converted to plasma YSI values (slope 1.66, intercept 0.12 for samples with normal hematocrit. Computed plasma levels compared to values determined by the laboratory standard method using Passing-Bablok regression yielded a slope of 1.03 (95%CI:0.99:1.08 with an intercept of -0.11 (95%CI:-0.18:-0.06. Conclusions: Whole blood YSI lactate values can be reliably converted into plasma values which are in line with laboratory determined plasma measurements. Keywords: Lactate, Plasma vs whole-blood, Hematocrit, Enzyme electrodes, Sample treatment

  5. Standing Up a Narcotic Confirmation Laboratory for the Russian Federation Ministry of Defense Nuclear Personnel Reliability Program

    International Nuclear Information System (INIS)

    Lukyanenko, Victor; Eisele, Gerhard R.; Coates, Cameron W.

    2010-01-01

    Through a cooperative effort between the U. S. Department of Energy and the Russian Federation (RF) Ministry of Defense (MOD) a Personnel Reliability Program (PRP) for the nuclear handlers within the RF MOD has been implemented. A key element in the RF MOD PRP is the detection and confirmation of narcotic use in subject military and civilian personnel. This paper describes the process of narcotics screening and testing in the RF MOD and explains the confirmation process once screening has shown a positive result. Issues of laboratory certification, employee certification, employee training, sample chain-of-custody, and equipment needs will be addressed.

  6. The IAEA worldwide intercomparison exercises (1990-1997). Determination of trace elements in marine sediments and biological samples

    International Nuclear Information System (INIS)

    Coquery, M.; Carvalho, F.P.; Azemard, S.; Horvat, M.

    1999-01-01

    Four major worldwide intercomparison exercises for the determination of trace elements in various environmental matrices were completed by the IAEA Marine Environment Laboratory since 1990: SD-M-2/TM, deep sea marine sediment; IAEA-350, tuna fish homogenate; IAEA-356, contaminated coastal sediment and IAEA-140, sea plant (Fucus sp.). These intercomparison exercises aim at enabling individual laboratories to monitor their performance. The results of these exercises allowed us to make an overall evaluation of the quality of data provided for environmental assessment and to identify the trends of analytical performance in the determination of trace elements over the years. The number of participants in each exercise varied between 68 and 130, and permits statistical evaluation of the performance for a number of elements. For each intercomparison exercise, the performance of the participant laboratories was assessed by comparing reported results with established reference values calculating 'Z-scores'. The results show that for each sample matrix, the values reported by some laboratories were far from satisfactory in the earlier exercises, in particular for Cd, Cr and Pb. Nevertheless, over time, a general improvement of performance can clearly be seen for all elements. Moreover, there was a noticeable increase in the number of laboratories with good performance in the two most recent exercises, observed both for biological and for sediment matrices. However, the determination of trace elements such as Cd, Cr, Pb and Hg in low level environmental samples still remains a major challenge to the analysts. For this reason and in order to assess the current performance of laboratories for low environmental levels of contaminants, the future intercomparison exercises will concentrate on low level sediment and fish samples

  7. International Intercomparison Exercise for Nuclear Accident Dosimetry at the DAF Using GODIVA-IV

    Energy Technology Data Exchange (ETDEWEB)

    Hickman, David [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hudson, Becka [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-12-15

    The Nuclear Criticality Safety Program operated under the direction of Dr. Jerry McKamy completed the first NNSA Nuclear Accident Dosimetry exercise on May 27, 2016. Participants in the exercise were from Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Sandia National Laboratory (SNL), Savanah River Site (SRS), Pacific Northwest National Laboratory (PNNL), US Navy, the Atomic Weapons Establishment (United Kingdom) under the auspices of JOWOG 30, and the Institute for Radiological Protection and Nuclear Safety (France) by special invitation and NCSP memorandum of understanding. This exercise was the culmination of a series of Integral Experiment Requests (IER) that included the establishment of the Nuclear Criticality Experimental Research Center, (NCERC) the startup of the Godiva Reactor (IER-194), the establishment of a the Nuclear Accident Dosimetry Laboratory (NAD LAB) in Mercury, NV, and the determination of reference dosimetry values for the mixed neutron and photon radiation field of Godiva within NCERC.

  8. Recumbent Stepper Submaximal Test response is reliable in adults with and without stroke.

    Directory of Open Access Journals (Sweden)

    David R Wilson

    Full Text Available The purpose of the present study was to determine the reliability of the exercise response (predicted peak VO2 using the total body recumbent stepper (TBRS submaximal exercise test in: 1 healthy adults 20-70 years of age and 2 adults participating in inpatient stroke rehabilitation. We hypothesized that the predicted peak VO2 (Visit 1 would have an excellent relationship (r > 0.80 to predicted peak VO2 (Visit 2. We also wanted to test whether the exercise response at Visit 1 and Visit 2 would be significantly different.Healthy adults were recruited from the Kansas City metro area. Stroke participants were recruited during their inpatient rehabilitation stay. Eligible participants completed 2 TBRS submaximal exercise tests between 24 hours and 5 days at similar times of day.A total of 70 participants completed the study. Healthy adults (n = 50 were 36 M, 38.1 ± 10.1 years and stroke participants (n = 20 were 15 M, 62.5 ± 11.8 years of age. The exercise response was reliable for healthy adults (r = 0.980, p<0.01 and stroke participants (r = 0.987, p<0.01 between Visit 1 and Visit 2. Repeated Measures ANOVA showed a significant difference in predicted values between the two visits for healthy adults (47.2 ± 8.4 vs 47.7 ± 8.5 mL∙kg-1∙min-1; p = 0.04 but not for stroke participants (25.0 ± 9.9 vs 25.3 ± 11.4 mL∙kg-1∙min-1; p = 0.65.These results suggest that the exercise response is reliable using the TBRS submaximal exercise test in this cohort of healthy adults and stroke participants.

  9. The SCI Exercise Self-Efficacy Scale (ESES: development and psychometric properties

    Directory of Open Access Journals (Sweden)

    Ho Pei-Shu

    2007-08-01

    Full Text Available Abstract Background Rising prevalence of secondary conditions among persons with spinal cord injury (SCI has focused recent attention to potential health promotion programs designed to reduce such adverse health conditions. A healthy lifestyle for people with SCI, including and specifically, the adoption of a vigorous exercise routine, has been shown to produce an array of health benefits, prompting many providers to recommend the implementation of such activity to those with SCI. Successfully adopting such an exercise regimen however, requires confidence in one's ability to engage in exercise or exercise self-efficacy. Exercise self-efficacy has not been assessed adequately for people with SCI due to a lack of validated and reliable scales, despite self efficacy's status as one of the most widely researched concepts and despite its broad application in health promotion studies. Exercise self efficacy supporting interventions for people with SCI are only meaningful if appropriate measurement tools exist. The objective of our study was to develop a psychometrically sound exercise self-efficacy self-report measure for people with SCI. Methods Based on literature reviews, expert comments and cognitive testing, 10 items were included and made up the 4-point Likert SCI Exercise Self-Efficacy Scale (ESES in its current form. The ESES was administered as part of the first wave of a nationwide survey (n = 368 on exercise behavior and was also tested separately for validity in four groups of individuals with SCI. Reliability and validity testing was performed using SPSS 12.0. Results Cronbach's alpha was .9269 for the ESES. High internal consistency was confirmed in split-half (EQ Length Spearman Brown = .8836. Construct validity was determined using principal component factor analysis by correlating the aggregated ESES items with the Generalised Self Efficacy Scale (GSE. We found that all items loaded on one factor only and that there was a

  10. SALIVARY CORTISOL RESPONSES AND PERCEIVED EXERTION DURING HIGH INTENSITY AND LOW INTENSITY BOUTS OF RESISTANCE EXERCISE

    Directory of Open Access Journals (Sweden)

    Alison D. Egan

    2004-03-01

    Full Text Available The purpose of this study was to measure the salivary cortisol response to different intensities of resistance exercise. In addition, we wanted to determine the reliability of the session rating of perceived exertion (RPE scale to monitor resistance exercise intensity. Subjects (8 men, 9 women completed 2 trials of acute resistance training bouts in a counterbalanced design. The high intensity resistance exercise protocol consisted of six, ten-repetition sets using 75% of one repetition maximum (RM on a Smith machine squat and bench press exercise (12 sets total. The low intensity resistance exercise protocol consisted of three, ten-repetition sets at 30% of 1RM of the same exercises as the high intensity protocol. Both exercise bouts were performed with 2 minutes of rest between each exercise and sessions were repeated to test reliability of the measures. The order of the exercise bouts was randomized with least 72 hours between each session. Saliva samples were obtained immediately before, immediately after and 30 mins following each resistance exercise bout. RPE measures were obtained using Borg's CR-10 scale following each set. Also, the session RPE for the entire exercise session was obtained 30 minutes following completion of the session. There was a significant 97% increase in the level of salivary cortisol immediately following the high intensity exercise session (P<0.05. There was also a significant difference in salivary cortisol of 145% between the low intensity and high intensity exercise session immediately post-exercise (P<0.05. The low intensity exercise did not result in any significant changes in cortisol levels. There was also a significant difference between the session RPE values for the different intensity levels (high intensity 7.1 vs. low intensity 1.9 (P<0.05. The intraclass correlation coefficient for the session RPE measure was 0.95. It was concluded that the session RPE method is a valid and reliable method of

  11. Comparison exercise of probabilistic precursor analysis

    International Nuclear Information System (INIS)

    Fauchille, V.; Babst, S.

    2004-01-01

    From 2000 up to 2003, a comparison exercise concerning accident precursor programs was performed by IRSN, GRS, and NUPEC (Japan). The objective of this exercise was to compare the methodologies used to quantify conditional core damage probability related to incidents which can be considered as accident precursors. This exercise provided interesting results concerning the interpretation of such events. Generally, the participants identified similar scenarios of potential degradation. However, for several dominant sequences, differences in the results were noticed. The differences can be attributed to variations in the plant design, the strategy of management and in the methodological approach. For many reasons, comparison of human reliability analysis was difficult and perhaps another exercise in the future could provide more information about this subject. On the other hand, interesting outcomes have been obtained from the quantification of both common cause failures and potential common cause failures. (orig.)

  12. Reliability in individual monitoring service.

    Science.gov (United States)

    Mod Ali, N

    2011-03-01

    As a laboratory certified to ISO 9001:2008 and accredited to ISO/IEC 17025, the Secondary Standard Dosimetry Laboratory (SSDL)-Nuclear Malaysia has incorporated an overall comprehensive system for technical and quality management in promoting a reliable individual monitoring service (IMS). Faster identification and resolution of issues regarding dosemeter preparation and issuing of reports, personnel enhancement, improved customer satisfaction and overall efficiency of laboratory activities are all results of the implementation of an effective quality system. Review of these measures and responses to observed trends provide continuous improvement of the system. By having these mechanisms, reliability of the IMS can be assured in the promotion of safe behaviour at all levels of the workforce utilising ionising radiation facilities. Upgradation of in the reporting program through a web-based e-SSDL marks a major improvement in Nuclear Malaysia's IMS reliability on the whole. The system is a vital step in providing a user friendly and effective occupational exposure evaluation program in the country. It provides a higher level of confidence in the results generated for occupational dose monitoring of the IMS, thus, enhances the status of the radiation protection framework of the country.

  13. Acute psychological benefits of exercise performed at self-selected workloads: implications for theory and practice.

    Science.gov (United States)

    Szabo, Attila

    2003-09-01

    Given that most studies to date examined the connection between exercise and affect without considering the participants' preferred exercise workload, in this research the affective-benefits of jogging or running at a participant-selected pace were investigated in a pilot field and a laboratory experiment. Ninety-six male and female students (19.5 yrs) took part in the pilot field experiment whereas 32 women (20.3 yrs) completed the laboratory experiment. In both experiments, the participants ran/jogged for 20 minutes at a self-selected pace. They completed an abbreviated version of a 'right now form' of the Profile of Mood States (POMS - Grove and Prapavessis, 1992) inventory before and after exercise. In both experiments all dependent measures changed significantly from pre- to post-exercise, except 'fatigue' and 'vigor' that did not change in the laboratory. Total mood disturbance (TMD) decreased significantly in both experiments (68% and 89%). No significant correlations were found between exercise intensity (expressed as percent (%) of maximal heart rate reserve) and the magnitude of changes seen in the dependent measures. It is concluded that exercising at a self-selected workload yields positive changes in affect that are unrelated to exercise intensity. These results suggest that the physiological theories linking exercise with positive changes in affect, in which exercise intensity is instrumental, could not account for the acute affective benefits of exercise. It is proposed that a 'cognitive appraisal hypothesis' may be more appropriate in explaining the acute affective benefits of exercise.

  14. Improvement of Student Understanding of How Kinetic Data Facilitates the Determination of Amino Acid Catalytic Function through an Alkaline Phosphatase Structure/Mechanism Bioinformatics Exercise

    Science.gov (United States)

    Grunwald, Sandra K.; Krueger, Katherine J.

    2008-01-01

    Laboratory exercises, which utilize alkaline phosphatase as a model enzyme, have been developed and used extensively in undergraduate biochemistry courses to illustrate enzyme steady-state kinetics. A bioinformatics laboratory exercise for the biochemistry laboratory, which complements the traditional alkaline phosphatase kinetics exercise, was…

  15. Effect of Video-Based versus Personalized Instruction on Errors during Elastic Tubing Exercises for Musculoskeletal Pain: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Kenneth Jay

    2014-01-01

    Full Text Available Workplace interventions have shown beneficial results of resistance training for chronic pain in the neck, shoulder, and arm. However, studies have relied on experienced exercise instructors, which may not be an available resource at most workplaces. The objective of this study is to evaluate the technical performance level of upper limb rehabilitation exercises following video-based versus personalized exercise instruction. We recruited 38 laboratory technicians and office workers with neck/shoulder pain for a two-week exercise training period receiving either (1 personal and video or (2 video only instruction in four typical neck/shoulder/arm rehabilitation exercises using elastic tubing. At a 2-week follow-up, the participants’ technical execution was assessed by two blinded physical therapists using a reliable error assessment tool. The error assessment was based on ordinal deviation of joint position from the ideal position of the shoulder, elbow, and wrist in a single plane by visual observation. Of the four exercises only unilateral shoulder external rotation had a higher normalized error score in the V group of 22.19 (9.30 to 12.64 (6.94 in the P group (P=0.002. For the remaining three exercises the normalized error score did not differ. In conclusion, when instructing simple exercises to reduce musculoskeletal pain the use of video material is a cost-effective solution that can be implemented easily in corporations with challenging work schedules not allowing for a fixed time of day to go see a personal trainer.

  16. Analysis of physical exercises and exercise protocols for space transportation system operation

    Science.gov (United States)

    Coleman, A. E.

    1982-01-01

    A quantitative evaluation of the Thornton-Whitmore treadmill was made so that informed management decisions regarding the role of this treadmill in operational flight crew exercise programs could be made. Specific tasks to be completed were: The Thornton-Whitmore passive treadmill as an exercise device at one-g was evaluated. Hardware, harness and restraint systems for use with the Thornton-Whitmore treadmill in the laboratory and in Shuttle flights were established. The quantitative and qualitative performance of human subjects on the Thorton-Whitmore treadmill with forces in excess of one-g, was evaluated. The performance of human subjects on the Thornton-Whitmore treadmill in weightlessness (onboard Shuttle flights) was also determined.

  17. Aerobic exercise decreases the positive-reinforcing effects of cocaine.

    Science.gov (United States)

    Smith, Mark A; Schmidt, Karl T; Iordanou, Jordan C; Mustroph, Martina L

    2008-11-01

    Aerobic exercise can serve as an alternative, non-drug reinforcer in laboratory animals and has been recommended as a potential intervention for substance abusing populations. Unfortunately, relatively little empirical data have been collected that specifically address the possible protective effects of voluntary, long-term exercise on measures of drug self-administration. The purpose of the present study was to examine the effects of chronic exercise on sensitivity to the positive-reinforcing effects of cocaine in the drug self-administration procedure. Female rats were obtained at weaning and immediately divided into two groups. Sedentary rats were housed individually in standard laboratory cages that permitted no exercise beyond normal cage ambulation; exercising rats were housed individually in modified cages equipped with a running wheel. After 6 weeks under these conditions, rats were surgically implanted with venous catheters and trained to self-administer cocaine on a fixed-ratio schedule of reinforcement. Once self-administration was acquired, cocaine was made available on a progressive ratio schedule and breakpoints were obtained for various doses of cocaine. Sedentary and exercising rats did not differ in the time to acquire cocaine self-administration or responding on the fixed-ratio schedule of reinforcement. However, on the progressive ratio schedule, breakpoints were significantly lower in exercising rats than sedentary rats when responding was maintained by both low (0.3mg/kg/infusion) and high (1.0mg/kg/infusion) doses of cocaine. In exercising rats, greater exercise output prior to catheter implantation was associated with lower breakpoints at the high dose of cocaine. These data indicate that chronic exercise decreases the positive-reinforcing effects of cocaine and support the possibility that exercise may be an effective intervention in drug abuse prevention and treatment programs.

  18. Nuclear power plant maintenance personnel reliability prediction (NPP/MPRP) effort at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Knee, H.E.; Haas, P.M.; Siegel, A.I.

    1981-01-01

    Human errors committed during maintenance activities are potentially a major contribution to the overall risk associated with the operation of a nuclear power plant (NPP). An NRC-sponsored program at Oak Ridge National Laboratory is attempting to develop a quantitative predictive technique to evaluate the contribution of maintenance errors to the overall NPP risk. The current work includes a survey of the requirements of potential users to ascertain the need for and content of the proposed quantitative model, plus an initial job/task analysis to determine the scope and applicability of various maintenance tasks. In addition, existing human reliability prediction models are being reviewed and assessed with respect to their applicability to NPP maintenance tasks. This paper discusses the status of the program and summarizes the results to date

  19. Retrospective radiation dosimetry using OSL of electronic components: Results of an inter-laboratory comparison

    International Nuclear Information System (INIS)

    Bassinet, C.; Woda, C.; Bortolin, E.; Della Monaca, S.; Fattibene, P.; Quattrini, M.C.; Bulanek, B.; Ekendahl, D.; Burbidge, C.I.; Cauwels, V.; Kouroukla, E.; Geber-Bergstrand, T.; Mrozik, A.; Marczewska, B.; Bilski, P.; Sholom, S.; McKeever, S.W.S.; Smith, R.W.; Veronese, I.

    2014-01-01

    In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an inter-laboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute from the USA, with various degrees of expertise in OSL dosimetry, took part in the OSL inter-laboratory comparison. Generally, a good agreement within uncertainties was observed between estimated and nominal doses. - Highlights: • Resistors in mobile phones could function as reliable fortuitous dosimeters in case of a large scale radiological accident. • Two OSL protocols were validated by an inter-laboratory comparison. • It is feasible to set up a network of laboratories so as to increase the measurement capacity

  20. Factorial Validity and Psychometric Examination of the Exercise Dependence Scale-Revised

    Science.gov (United States)

    Downs, Danielle Symons; Hausenblas, Heather A.; Nigg, Claudio R.

    2004-01-01

    The research purposes were to examine the factorial and convergent validity, internal consistency, and test-retest reliability of the Exercise Dependence Scale (EDS). Two separate studies, containing a total of 1,263 college students, were undertaken to accomplish these purposes. Participants completed the EDS and measures of exercise behavior and…

  1. First intercomparison exercise for Argentine organized by the ARN for the determination of uranium in water and urine samples

    International Nuclear Information System (INIS)

    Serdeiro, Nelida H.; Equillor, Hugo E.

    2004-01-01

    An exercise of intercomparison organized by the Nuclear Regulatory Authority was carried out during the year 2000 for the determination of uranium in samples of water and urine. The exercise was designed to compare the values of uranium obtained by the different laboratories for the same sample, and to promote the identification of the uncertainties linked with the process of obtaining the results. Six laboratories that usually do this type of analysis participated in the exercise. The values informed by the laboratories are presented, as well as an evaluation of the performance of each laboratory

  2. Unsupervised progressive elastic band exercises for frail geriatric inpatients objectively monitored by new exercise-integrated technology

    DEFF Research Database (Denmark)

    Rathleff, Camilla Rams; Bandholm, T.; Spaich, Erika Geraldina

    2017-01-01

    the amount of supervised training, and unsupervised training could possibly supplement supervised training thereby increasing the total exercise dose during admission. A new valid and reliable technology, the BandCizer, objectively measures the exact training dosage performed. The purpose was to investigate...... feasibility and acceptability of an unsupervised progressive strength training intervention monitored by BandCizer for frail geriatric inpatients. Methods: This feasibility trial included 15 frail inpatients at a geriatric ward. At hospitalization, the patients were prescribed two elastic band exercises...... of 2-min pauses and a time-under-tension of 8 s. The feasibility criterion for the unsupervised progressive exercises was that 33% of the recommended number of sets would be performed by at least 30% of patients. In addition, patients and staff were interviewed about their experiences...

  3. Exercise barriers self-efficacy: development and validation of a subcale for individuals with cancer-related lymphedema.

    Science.gov (United States)

    Buchan, Jena; Janda, Monika; Box, Robyn; Rogers, Laura; Hayes, Sandi

    2015-03-18

    No tool exists to measure self-efficacy for overcoming lymphedema-related exercise barriers in individuals with cancer-related lymphedema. However, an existing scale measures confidence to overcome general exercise barriers in cancer survivors. Therefore, the purpose of this study was to develop, validate and assess the reliability of a subscale, to be used in conjunction with the general barriers scale, for determining exercise barriers self-efficacy in individuals facing lymphedema-related exercise barriers. A lymphedema-specific exercise barriers self-efficacy subscale was developed and validated using a cohort of 106 cancer survivors with cancer-related lymphedema, from Brisbane, Australia. An initial ten-item lymphedema-specific barrier subscale was developed and tested, with participant feedback and principal components analysis results used to guide development of the final version. Validity and test-retest reliability analyses were conducted on the final subscale. The final lymphedema-specific subscale contained five items. Principal components analysis revealed these items loaded highly (>0.75) on a separate factor when tested with a well-established nine-item general barriers scale. The final five-item subscale demonstrated good construct and criterion validity, high internal consistency (Cronbach's alpha = 0.93) and test-retest reliability (ICC = 0.67, p exercise barriers self-efficacy in individuals with cancer-related lymphedema. This scale can be used in conjunction with an existing general exercise barriers scale to enhance exercise adherence in this understudied patient group.

  4. Design of the Laboratory-Scale Plutonium Oxide Processing Unit in the Radiochemical Processing Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Lumetta, Gregg J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Meier, David E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tingey, Joel M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Casella, Amanda J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Delegard, Calvin H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Edwards, Matthew K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Orton, Robert D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rapko, Brian M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Smart, John E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-05-01

    This report describes a design for a laboratory-scale capability to produce plutonium oxide (PuO2) for use in identifying and validating nuclear forensics signatures associated with plutonium production, as well as for use as exercise and reference materials. This capability will be located in the Radiochemical Processing Laboratory at the Pacific Northwest National Laboratory. The key unit operations are described, including PuO2 dissolution, purification of the Pu by ion exchange, precipitation, and re-conversion to PuO2 by calcination.

  5. Effects of concurrent and aerobic exercises on postexercise hypotension in elderly hypertensive men.

    Science.gov (United States)

    Ferrari, Rodrigo; Umpierre, Daniel; Vogel, Guilherme; Vieira, Paulo J C; Santos, Lucas P; de Mello, Renato Bandeira; Tanaka, Hirofumi; Fuchs, Sandra C

    2017-11-01

    Despite the fact that simultaneous performance of resistance and aerobic exercises (i.e., concurrent exercise) has become a standard exercise prescription for the elderly, no information is available on its effects on post-exercise hypotension (PEH) in elderly men with hypertension. To compare the effects of different types of exercise on PEH in elderly men with hypertension. Twenty elderly men with essential hypertension participated in three crossover interventions, in random order, and on separate days: a non-exercise control session at seated rest, aerobic exercise performed for 45min, and 45min of concurrent resistance and aerobic exercise consisted of 4 sets of 8 repetitions at 70% 1RM of resistance exercise followed by aerobic exercise on treadmill. After each session, blood pressure (BP) was measured continuously for 1h in the laboratory and for 24h under ambulatory conditions. During the first hour in laboratory, diastolic BP was lower after aerobic (-5mmHg) and concurrent exercise (-6mmHg) in comparison with Control. Day-time diastolic BP was significantly lower after aerobic exercise (-7mmHg) when compared to the control. No significant differences were found among the three experimental sessions for night-time and 24-hour diastolic BP, as well as day-time, night-time and 24-hour systolic BP. Concurrent exercise produced acute PEH similar to aerobic exercise but such effect did not last as long as aerobic exercise in elderly patients with essential hypertension. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. CONFIRMATION OF THE BASIC PSYCHOLOGICAL NEEDS IN EXERCISE SCALE (BPNES WITH A SAMPLE OF PEOPLE WHO DO HEALTHY EXERCISE

    Directory of Open Access Journals (Sweden)

    Juan A. Moreno-Murcia

    2012-03-01

    Full Text Available This study aimed to cross-validate the psychometric properties of the Basic Psychological Needs in Exercise Scale (BPNES by Vlachopoulos and Michailidou, 2006 in a Spanish context. Two studies were conducted. Confirmatory factor analysis results confirmed the hypothesized three-factor solution In addition, we documented evidence of reliability, analysed as internal consistency and temporal stability. Future studies should analyse the scale's validity and reliability with different populations and check their experimental effect

  7. A clean laboratory for ultratrace analysis: the ultratrace analytical facility (UTAF)

    International Nuclear Information System (INIS)

    Jadhav, S.G.; Sounderajan, Suvarna; Kumar, Sanjukta A.; Udas, A.C.; Ramanathan, M.; Palrecha, M.M.; Sudersanan, M.

    2003-06-01

    Thare has been an increasing demand for the quantification of various elements at extremely low concentrations in a variety of samples such as high purity materials, environmental and biological samples. The need for a controlled environment to obtain reliable and reproducible data necessitates the use of strategies and practices to minimize contamination during the analytical procedure. This report describes the protocol observed in our clean laboratory to eliminate contamination and ensure low laboratory blanks and some of the methodologies developed to carry out the analysis. The analysis is carried out by Graphite Furnace Atomic Absorption Spectrometry and electrochemical techniques such as Anodic/ Cathodic / Adsorptive Stripping Voltammetry. Characterisation of 5N (total impurities 10 ppm) arsenic is routinely carried out. Al in serum of patients suffering from end stage renal failure are also analyzed. Pine leaves, spinach, carrot puree and milk powder have been characterized for Al and Hg content and bovine serum has been characterized for Cu, Zn, Na, K in samples as part of intercomparison exercises. (author)

  8. Participation of the Laboratorio de Radiotoxicologia of IPEN, SP, Brazil, in laboratory inter-comparison programs

    International Nuclear Information System (INIS)

    Mesquita, Sueli Alexandra de; Carneiro, Janete Cristina G.

    2005-01-01

    The Radiotoxicology Laboratory (LRT) of IPEN/CNEN-SP has as mission to assess internal internal contamination from individuals through qualitative and quantitative analysis of radionuclides present in biological samples. The LRT is able to meet the demand for in vitro monitoring and radiological and nuclear emergencies, both in the case of occupational exposures, as individuals. With the purpose of increasing the reliability of the test results, and keeping it up to date on new analytical techniques, the LRT participates annually in two laboratory inter-comparison programs: a national, the PNI (Programa Nacional de Intercomparacao), promoted by IRD/CNEN and an international from PROCORAD (Association for the Promotion of Quality Controls in Radiotoxicological Bioassay). The present work shows the performance of the LRT by means of the results obtained in the exercises for the quantification of natural uranium and uranium isotopes, promoted by both the inter-comparison programs in the year of 2004. The analysis of the obtained results demonstrates the good performance achieved by LRT, and confirms the sustainability of its quality system, required in calibration and testing laboratories

  9. ACUTE PSYCHOLOGICAL BENEFITS OF EXERCISE PERFORMED AT SELF-SELECTED WORKLOADS: IMPLICATIONS FOR THEORY AND PRACTICE

    Directory of Open Access Journals (Sweden)

    Attila Szabo

    2003-09-01

    Full Text Available Given that most studies to date examined the connection between exercise and affect without considering the participants' preferred exercise workload, in this research the affective-benefits of jogging or running at a participant-selected pace were investigated in a pilot field and a laboratory experiment. Ninety-six male and female students (19.5 yrs took part in the pilot field experiment whereas 32 women (20.3 yrs completed the laboratory experiment. In both experiments, the participants ran/jogged for 20 minutes at a self-selected pace. They completed an abbreviated version of a 'right now form' of the Profile of Mood States (POMS - Grove and Prapavessis, 1992 inventory before and after exercise. In both experiments all dependent measures changed significantly from pre- to post-exercise, except 'fatigue' and 'vigor' that did not change in the laboratory. Total mood disturbance (TMD decreased significantly in both experiments (68% and 89%. No significant correlations were found between exercise intensity (expressed as percent (% of maximal heart rate reserve and the magnitude of changes seen in the dependent measures. It is concluded that exercising at a self-selected workload yields positive changes in affect that are unrelated to exercise intensity. These results suggest that the physiological theories linking exercise with positive changes in affect, in which exercise intensity is instrumental, could not account for the acute affective benefits of exercise. It is proposed that a 'cognitive appraisal hypothesis' may be more appropriate in explaining the acute affective benefits of exercise

  10. The PISC exercise: a discussion of its relevance to ultrasonic inspection of pressure vessels

    International Nuclear Information System (INIS)

    Whittle, M.J.; Coffey, J.M.

    1981-01-01

    The value of the European Plate Inspection Steering Committee (PISC) exercise for determining the reliability of ultrasonic inspection of pressure vessels is discussed. It is argued that the particular ultrasonic procedure assessed in the exercise was a poor one whose failure was predictable. In addition the test blocks were sufficiently unrealistic that the value of the results would have been diminished even if all the defects had been found. Consequently the report maintains that the outcome of the exercise is largely irrelevant to the wider question of the reliability of more thorough ultrasonic procedures. A more general discussion is given of the role of test block studies in ultrasonics. Statistical arguments are used to show that it is impracticable to produce a sufficient number of defects to demonstrate a high reliability and have a high confidence in such a result. Some important points for planning future programmes are emphasised. (author)

  11. Environmental radioactivity measurement intercomparison exercise 1990

    International Nuclear Information System (INIS)

    Jerome, S.M.

    1991-05-01

    In a recent national intercomparison exercise, 49 laboratories involved in making environmental radioactivity measurements took part in the analysis of samples supplied by the National Physical Laboratory (NPL) in the United Kingdom. There were two sets of samples; one containing pure β-emitters and one containing β/γ-emitters. Two thirds of the participants measured the β/γ-emitter sample only, the remainder measured both. The results are presented. (author)

  12. The Development of Low-Level Measurement Capabilities for Total and Isotopic Uranium in Environmental Samples at Brazilian and Argentine Laboratories by ABACC

    International Nuclear Information System (INIS)

    Guidicini, Olga M.; Olsen, Khris B.; Hembree, Doyle M.; Carter, Joel A.; Whitaker, Michael; Hayes, Susan M.

    2005-01-01

    In June 1998, the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC), with assistance from the U.S. Department of Energy (DOE), began a program to assess environmental sampling and analysis capabilities at laboratories in Argentina and Brazil. The program began with staff training conducted in South America and the United States by Oak Ridge National Laboratory (ORNL) and Pacific Northwest National Laboratory (PNNL). Both laboratories are participating members of DOE's Network of Analytical Laboratories (NWAL) that support IAEA's environmental sampling program. During the initial planning meeting, representatives from ABACC and all the participating analytical laboratories supporting ABACC were briefed on how the first exercise would be managed and on key aspects necessary to analyze low-level environmental samples for uranium. Subsequent to this training, a laboratory evaluation exercise (Exercise 1) was conducted using standard swipe samples prepared for this exercise by the International Atomic Energy Agency (IAEA). The results of Exercise 1 determined that sample contamination was a major factor in the analysis, and a thorough review of laboratory procedures was required to reduce the level of contamination to acceptable levels. Following modification of sample preparation procedures, the laboratories performed Exercise 2, an analysis of a National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 1547, Peach Leaves. The results of Exercise 2 demonstrated that several laboratories were capable of accurately determining the total uranium and uranium isotopic distribution in the peach leaves. To build on these successes, Exercise 3 was performed using a series of standard swipe samples prepared by the IAEA and distributed to laboratories supporting ABACC and to PNNL and ORNL. The results of Exercise 3 demonstrate that ABACC now has support laboratories in both Argentina and Brazil, which are capable of

  13. An analog integrated circuit design laboratory

    OpenAIRE

    Mondragon-Torres, A.F.; Mayhugh, Jr.; Pineda de Gyvez, J.; Silva-Martinez, J.; Sanchez-Sinencio, E.

    2003-01-01

    We present the structure of an analog integrated circuit design laboratory to instruct at both, senior undergraduate and entry graduate levels. The teaching material includes: a laboratory manual with analog circuit design theory, pre-laboratory exercises and circuit design specifications; a reference web page with step by step instructions and examples; the use of mathematical tools for automation and analysis; and state of the art CAD design tools in use by industry. Upon completion of the ...

  14. Development and psychometric evaluation of the Dialysis patient-perceived Exercise Benefits and Barriers Scale.

    Science.gov (United States)

    Zheng, Jing; You, Li-Ming; Lou, Tan-Qi; Chen, Nian-Chang; Lai, De-Yuan; Liang, Yan-Yi; Li, Ying-Na; Gu, Ying-Ming; Lv, Shao-Fen; Zhai, Cui-Qiu

    2010-02-01

    Perceptions of exercise benefits and barriers affect exercise behavior. Because of the clinical course and treatment, dialysis patients differ from the general population in their perceptions of exercise benefits and barriers, especially the latter. At present, no valid instruments for assessing perceived exercise benefits and barriers in dialysis patients are available. Our goal was to develop and test the psychometric properties of the Dialysis patient-perceived Exercise Benefits and Barriers Scale (DPEBBS). A literature review and two focus groups were conducted to generate the initial item pool. An expert panel examined the content validity. Then, 269 Chinese hemodialysis patients were recruited by convenience sampling. Exploratory and confirmatory factor analyses were used to test construct validity. Finally, internal consistency and test-retest reliability were assessed. The expert panel determined that the content validity index was satisfactory. The final 24-item scale consisted of six factors explaining 57% of the total variance in the data. Confirmative factor analysis supported the six-factor structure and a higher-order model. Cronbach's alpha was 0.87 for the total scale, and 0.84 for test-retest reliability. The DPEBBS was a valid and reliable instrument for evaluating dialysis patients' perceived benefits and barriers to exercise. The application value of this scale remains to be investigated by increasing the sample size and evaluating patients undergoing different dialysis modalities and coming from different regions and cultural backgrounds. Copyright 2009 Elsevier Ltd. All rights reserved.

  15. Lessons learnt from participation in international inter-comparison exercise for environmental radioactivity measurement

    International Nuclear Information System (INIS)

    Jha, S.K.; Pulhani, Vandana; Sartandel, Sangeeta

    2016-06-01

    Environmental Radioactivity Measurement Section of Health Physics Division is regularly carrying out surveillance of the radioactivity concentration in the environment. The laboratory participates in the inter-comparison exercises conducted by various international agencies for quality assurance and quality control of analytical estimations. This report summarizes the results of the analysis of radioactivity in environmental matrices of the inter-comparison exercises. The participation in inter-comparison exercises has demonstrated competence in radionuclide identification and estimations, equivalence with the results of other participating laboratories, validated adopted analytical methods, introduced traceability to measurement etc. at national and international level. (author)

  16. Getting Real: A General Chemistry Laboratory Program Focusing on "Real World" Substances

    Science.gov (United States)

    Kerber, Robert C.; Akhtar, Mohammad J.

    1996-11-01

    "real world" substances, however, we have also devised some new laboratory exercises or adapted existing ones. Sources are cited in Table 1 and in the references; in most cases, published exercises have been extended and modified to fit our theme. Some general descriptions of the more novel exercises appear below. We will be pleased to provide details on any of the exercises to interested readers. 6. To further emphasize the quotidian nature of the samples under study, we have encouraged students to bring their own samples to the laboratory by offering a small number of bonus points (up to 5% of the total points awarded in the course). Student participation has been very gratifying, with two-thirds of the students, on average, bringing in designated materials (indicated in Table 1). Although our primary purpose in encouraging "bring your own" is pedagogical, we are not unaware of a favorable effect on the course budget. 7. Fill-in-the-blank report forms are used to guide calculations in the quantitative exercises, helping to assure reliable conversion of measurements into meaningful results that allow comparison of various student samples. In the more qualitative exercises, however, we emphasize use of the laboratory notebook for record-keeping (3). As an incentive for development of good notebook habits, students are allowed to use their laboratory notebooks on lab quizzes, and the notebooks themselves are graded for thoroughness and accuracy at least once each semester. 8. Most laboratory exercises are conducted on an S/U basis. Numerically graded exercises, indicated in Table 1, are performed only after students have gained experience in basic operations by working on S/U exercises. Some Features of the More Novel Exercises 1. In "Identification of Household `Chemicals' ", each student is given a white powder and a list of some twenty such powders that might be found in or around an American household. They perform some simple solubility and reactivity tests and

  17. Analysis of laboratory intercomparison data: a matter of independence

    Directory of Open Access Journals (Sweden)

    Mauro F. Rebelo

    2003-05-01

    Full Text Available When laboratory intercomparison exercises are conducted, there is no a priori dependence of the concentration of a certain compound determined in one laboratory to that determined by another(s. The same applies when comparing different methodologies. A existing data set of total mercury readings in fish muscle samples involved in a Brazilian intercomparison exercise was used to show that correlation analysis is the most effective statistical tool in this kind of experiments. Problems associated with alternative analytical tools such as mean or paired 't'-test comparison and regression analysis are discussed.

  18. Final report on the REAL-84 exercise

    International Nuclear Information System (INIS)

    Zijp, W.L.; Nolthenius, H.J.

    1988-11-01

    The main aim of the REAL-84 exercise, organized by the International Atomic Energy Agency in Vienna, was to improve the assessment of accuracies in radiation damage predictions by various laboratories using good quality input data and proper calculation methods. The emphasis was concentrated on radiation damage characterization to reactor pressure vessels and related neutron technology. The long term aim of this exercise was to strive towards the establishment of standardized metrology procedures and recommended nuclear data for use in spectrum adjustment and damage parameter calculations. In this calculation exercise dealing with seven different neutron spectra the best available input data were used. Also some utility programs were included to facilitate the preparation of input data for the adjustment codes. This final report presents a discussion on the 44 sets of adjustment results received from 12 laboratories. The comparison of the results of the various spectra showed in most cases a relatively large and unexpected interlaboratory spread. Attention is given to this phenomenon. Also the quality of the input data set and a characterization of covariance matrices is summarized

  19. Altered gas-exchange at peak exercise in obese adolescents: implications for verification of effort during cardiopulmonary exercise testing.

    Science.gov (United States)

    Marinus, Nastasia; Bervoets, Liene; Massa, Guy; Verboven, Kenneth; Stevens, An; Takken, Tim; Hansen, Dominique

    2017-12-01

    Cardiopulmonary exercise testing is advised ahead of exercise intervention in obese adolescents to assess medical safety of exercise and physical fitness. Optimal validity and reliability of test results are required to identify maximal exercise effort. As fat oxidation during exercise is disturbed in obese individuals, it remains an unresolved methodological issue whether the respiratory gas exchange ratio (RER) is a valid marker for maximal effort during exercise testing in this population. RER during maximal exercise testing (RERpeak), and RER trajectories, was compared between obese and lean adolescents and relationships between RERpeak, RER slope and subject characteristics (age, gender, Body Mass Index [BMI], Tanner stage, physical activity level) were explored. Thirty-four obese (BMI: 35.1±5.1 kg/m²) and 18 lean (BMI: 18.8±1.9 kg/m²) adolescents (aged 12-18 years) performed a maximal cardiopulmonary exercise test on bike, with comparison of oxygen uptake (VO2), heart rate (HR), expiratory volume (VE), carbon dioxide output (VCO2), and cycling power output (W). RERpeak (1.09±0.06 vs. 1.14±0.06 in obese vs. lean adolescents, respectively) and RER slope (0.03±0.01 vs. 0.05±0.01 per 10% increase in VO2, in obese vs. lean adolescents, respectively) was significantly lower in obese adolescents, and independently related to BMI (Pexercise testing in this population.

  20. Psychobiological mechanisms of exercise dependence.

    Science.gov (United States)

    Hamer, Mark; Karageorghis, Costas I

    2007-01-01

    Exercise dependence (ED) is characterised by an obsessive and unhealthy preoccupation with exercise. Previous research has focused largely on identifying behavioural aspects of ED, although the biological mechanisms remain unknown and are under researched. We review various ED hypotheses including affect regulation, anorexia analogue, sympathetic arousal and beta-endorphin. We also present a novel hypothesis pertaining to ED and interleukin (IL)-6, which combines previous hypotheses with literature from the field of psycho-neuroimmunology. We explore the notion that IL-6 provides a link from the periphery to the brain, which may mediate the underlying features of ED. We propose a conceptual model indicating that, in individuals prone to ED, exercise results in a transient reduction in negative affect, but concurrently results in excessive production of IL-6 and the activation of neuroendocrine pathways, which are associated with behavioural and psychological disturbances of exercise withdrawal. Our intention is for this model to serve as a basis for further research in the area of ED, which may eventually lead to the development of successful treatment strategies. Recent developments in methods to reliably assess these biological markers from blood and saliva samples should encourage such research to be undertaken in exercise settings.

  1. Why don't you exercise? Development of the Amotivation Toward Exercise Scale among older inactive individuals.

    Science.gov (United States)

    Vlachopoulos, Symeon P; Gigoudi, Maria A

    2008-07-01

    This article reports on the development and initial validation of the Amotivation Toward Exercise Scale (ATES), which reflects a taxonomy of older adults' reasons to refrain from exercise. Drawing on work by Pelletier, Dion, Tuson, and Green-Demers (1999) and Legault, Green-Demers, and Pelletier (2006), these dimensions were the outcome beliefs, capacity beliefs, effort beliefs, and value amotivation beliefs toward exercise. The results supported a 4-factor correlated model that fit the data better than either a unidimensional model or a 4-factor uncorrelated model or a hierarchical model with strong internal reliability for all the subscales. Evidence also emerged for the discriminant validity of the subscale scores. Furthermore, the predictive validity of the subscale scores was supported, and satisfactory measurement invariance was demonstrated across the calibration and validation samples, supporting the generalizability of the scale's measurement properties.

  2. An inter-laboratory comparison of Si isotope reference materials

    NARCIS (Netherlands)

    Reynolds, B.C.; Aggarwal, J.; André, L.; Baxter, B.; Beucher, C.; Brzezinski, M.A.; Engström, E.; Georg, R.B.; Land, M.; Leng, M.J.; Opfergelt, S.; Rodushkin, I.; Sloane, H.J.; Van den Boorn, S.H.J.M.; Vroon, P.Z.; Cardinal, D.

    2007-01-01

    Three Si isotope materials have been used for an inter-laboratory comparison exercise to ensure reproducibility between international laboratories investigating natural Si isotope variations using a variety of chemical preparation methods and mass spectrometric techniques. These proposed standard

  3. Exercise self-efficacy in persons with spinal cord injury: psychometric properties of the Dutch translation of the Exercise Self-Efficacy Scale.

    Science.gov (United States)

    Nooijen, Carla F J; Post, Marcel W M; Spijkerman, Dorien C M; Bergen, Michael P; Stam, Henk J; van den Berg-Emons, Rita J G

    2013-04-01

    To assess the reliability and validity of the Dutch version of the exercise self-efficacy scale (ESES) in persons with spinal cord injury. This is the first independent study of ESES psychometric properties, and the first report on ESES test-retest reliability. A total of 53 Dutch persons with spinal cord injury. Subjects completed the Dutch ESES twice, with 2 weeks between (ESES_1 and ESES_2). Subjects also completed the General self-efficacy scale (GSE), and a questionnaire regarding demographic characteristics and lesion characteristics. Psychometric properties of the Dutch translation of the ESES were assessed and compared with those of the original English-language version. The Dutch ESES was found to have good internal consistency (Cronbach's α for ESES_1 = 0.90, ESES_2 = 0.88). Test-retest reliability was adequate (intra-class correlation coefficient = 0.81, 95% confidence interval 0.70-0.89). For validity, a moderate, statistically significant correlation was found between ESES and the GSE (Spearman's ρ ESES_1 = 0.52, ESES_2 = 0.66, p exercise self-efficacy.

  4. Measuring skin temperature before, during and after exercise: a comparison of thermocouples and infrared thermography

    International Nuclear Information System (INIS)

    Fernandes, Alex de Andrade; Amorim, Paulo Roberto dos Santos; De Moura, Anselmo Gomes; Moreira, Danilo Gomes; Costa, Carlos Magno Amaral; Marins, João Carlos Bouzas; Brito, Ciro José; Sillero-Quintana, Manuel

    2014-01-01

    Measuring skin temperature (T SK ) provides important information about the complex thermal control system and could be interesting when carrying out studies about thermoregulation. The most common method to record T SK  involves thermocouples at specific locations; however, the use of infrared thermal imaging (IRT) has increased. The two methods use different physical processes to measure T SK , and each has advantages and disadvantages. Therefore, the objective of this study was to compare the mean skin temperature (MT SK ) measurements using thermocouples and IRT in three different situations: pre-exercise, exercise and post-exercise. Analysis of the residual scores in Bland–Altman plots showed poor agreement between the MT SK  obtained using thermocouples and those using IRT. The averaged error was −0.75 °C during pre-exercise, 1.22 °C during exercise and −1.16 °C during post-exercise, and the reliability between the methods was low in the pre- (ICC = 0.75 [0.12 to 0.93]), during (ICC = 0.49 [−0.80 to 0.85]) and post-exercise (ICC = 0.35 [−1.22 to 0.81] conditions. Thus, there is poor correlation between the values of MT SK  measured by thermocouples and IRT pre-exercise, exercise and post-exercise, and low reliability between the two forms of measurement. (paper)

  5. Grimsel colloid exercise

    International Nuclear Information System (INIS)

    Degueldre, C.; Longworth, G.; Vilks, P.

    1989-11-01

    The Grimsel Colloid Exercise was an intercomparison exercise which consisted of an in situ sampling phase followed by a colloid characterisation step. The goal of this benchmark exercise, which involved 12 laboratories, was to evaluate both sampling and characterisation techniques with emphasis on the colloid specific size distribution. The sampling phase took place at the Grimsel Test Site between February 1 and 13, 1988 and the participating groups produced colloid samples using the following methods: 1. Cross-flow ultrafiltration with production of membranes loaded with colloids. 2. Tangential diaultrafiltration and production of colloid concentrates. 3. Filtrates produced by each group. 4. Unfiltered water was also collected by PSI in glass bottles, under controlled anaerobic conditions, and by the other sampling groups in various plastic bottles. In addition, on-line monitoring of pH, χ, [O-2] and T of the water and of [O-2] in the atmosphere of the sampling units was carried out routinely. All samples were shipped according to the CoCo Club scheme for characterisation, with emphasis on the size distribution. The exercise differentiates the colloid samples produced on site from those obtained after transfer of the fluid samples to the laboratories. The colloid concentration and size distribution can be determined by scanning electron microscopy (SEM), gravimetry (GRAV), chemical analysis of fluid samples after micro/ultrafiltration (MF/UF) and by transmission single particle counting (PC). The colloid concentration can also be evaluated by transmission electron microscopy (TEM), static and dynamic light scattering (SLS,DLS) and by laser-induced photoacoustic spectroscopy (LPAS). The results are discussed on the basis of the detection limit, lateral resolution and counting conditions of the technique (precision) as well as sample preparation, artefact production and measurement optimisation (accuracy). A good agreement between size distribution results was

  6. The nuclear weapons fallout preparedness exercise LOTTA. A presentation and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Tovedal, H

    2000-10-01

    This report contains a presentation and evaluation of an emergency preparedness exercise (LOTTA) that was carried out at FOA NBC Defense in May 1998. The exercise scenario was based on a nuclear weapons explosion in Norway and the paper describes the development of the scenario including weather prognosis for the simulation of dose rate-, laboratory- and field measurements made during the exercise. An evaluation of the different functions trained is also given. This is the main report in a series of reports concerning exercise LOTTA.

  7. The nuclear weapons fallout preparedness exercise LOTTA. A presentation and evaluation

    International Nuclear Information System (INIS)

    Tovedal, H.

    2000-10-01

    This report contains a presentation and evaluation of an emergency preparedness exercise (LOTTA) that was carried out at FOA NBC Defense in May 1998. The exercise scenario was based on a nuclear weapons explosion in Norway and the paper describes the development of the scenario including weather prognosis for the simulation of dose rate-, laboratory- and field measurements made during the exercise. An evaluation of the different functions trained is also given. This is the main report in a series of reports concerning exercise LOTTA

  8. Psychometric evaluations of the efficacy expectations and Outcome Expectations for Exercise Scales in African American women.

    Science.gov (United States)

    Murrock, Carolyn J; Gary, Faye

    2014-01-01

    This secondary analysis tested the reliability and validity of the Self-Efficacy for Exercise (SEE) and the Outcome Expectations for Exercise (OEE) scales in 126 community dwelling, middle aged African American women. Social Cognitive Theory postulates self-efficacy is behavior age, gender and culture specific. Therefore, it is important to determine ifself-efficacy scales developed and tested in older Caucasian female adults are reliable and valid in middle aged, minority women. Cronbach's alpha and construct validity using hypothesis testing and confirmatory factor analysis supported the reliability and validity of the SEE and OEE scales in community dwelling, middle aged African American women.

  9. Experience of an inter-laboratory exercise for the determination of Carbon-14 in biological samples

    International Nuclear Information System (INIS)

    Baburajan, A.; Rajaram, S.; D'Souza, Renita Shiny; Nayak, Rasmi; Karunakara, N.; Ravi, P.M.; Tripathi, R.M.

    2018-01-01

    Carbon-14 is one of the naturally occurring cosmogenic nuclide with long half life of 5730 y and beta energy, E max : 156 keV produced continuously in the outer atmosphere. It is also produced by the anthropogenic activities like nuclear weapon test, nuclear power plant etc. contributing to the atmospheric inventory. The 14 CO 2 gets incorporated with the plant species during photosynthesis and ultimately reaches to man through food chain. It is important to accurately quantify the level of 14 C in different biological matrices for the computation of radiation dose due to ingestion. There are different methods available for the determination of 14 C in biological samples. The oxidation of the dried sample is one of the methods used for liberating the 14 CO 2 and which in turn re-absorbed using Carbo Sorb and subjected to Liquid scintillation analyses with Permaflour scintillator solution. The paper deals with the quality assurance programme initiated by ESL, Tarapur along with ESL, Kalpakkam and CARER, Mangalore University and share the experience of the inter-laboratory comparison exercise

  10. Reliability engineering theory and practice

    CERN Document Server

    Birolini, Alessandro

    2017-01-01

    This book shows how to build in and assess reliability, availability, maintainability, and safety (RAMS) of components, equipment, and systems. It presents the state of the art of reliability (RAMS) engineering, in theory & practice, and is based on over 30 years author's experience in this field, half in industry and half as Professor of Reliability Engineering at the ETH, Zurich. The book structure allows rapid access to practical results. Methods & tools are given in a way that they can be tailored to cover different RAMS requirement levels. Thanks to Appendices A6 - A8 the book is mathematically self-contained, and can be used as a textbook or as a desktop reference with a large number of tables (60), figures (210), and examples / exercises^ 10,000 per year since 2013) were the motivation for this final edition, the 13th since 1985, including German editions. Extended and carefully reviewed to improve accuracy, it represents the continuous improvement effort to satisfy reader's needs and confidenc...

  11. The nuclear power plant maintenance personnel reliability prediction (NPP/MPRP) effort at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Knee, H.E.; Haas, P.M.; Siegel, A.I.

    1982-01-01

    Human errors committed during maintenance activities are potentially a major contribution to the overall risk associated with the operation of a nuclear power plant (NPP). An NRC-sponsored program at Oak Ridge National Laboratory is attempting to develop a quantitative predictive technique to evaluate the contribution of maintenance errors to the overall NPP risk. The current work includes a survey of the requirements of potential users to ascertain the need for and content of the proposed quantitative model, plus an initial job/task analysis to determine the scope and applicability of various maintenance tasks. In addition, existing human reliability prediction models are being reviewed and assessed with respect to their applicability to NPP maintenance tasks. This paper discusses the status of the program and summarizes the results to date

  12. mRNA profiling for the identification of blood-Results of a collaborative EDNAP exercise

    DEFF Research Database (Denmark)

    Haas, Cordula; Hanson, E; Bär, W

    2010-01-01

    of the laboratories had no prior experience with RNA. Despite some expected variation in sensitivity between laboratories, the method proved to be reproducible and sensitive using different analysis strategies. The results of this collaborative exercise support the potential use of mRNA profiling as an alternative......A collaborative exercise on mRNA profiling for the identification of blood was organized by the European DNA Profiling Group (EDNAP). Seven blood samples and one blood dilution series were analyzed by the participating laboratories for the reportedly blood-specific markers HBB, SPTB and PBGD, using...

  13. mRNA profiling for the identification of blood--Results of a collaborative EDNAP exercise

    DEFF Research Database (Denmark)

    Haas, C.; Hanson, E.; Bär, W.

    2011-01-01

    of the laboratories had no prior experience with RNA. Despite some expected variation in sensitivity between laboratories, the method proved to be reproducible and sensitive using different analysis strategies. The results of this collaborative exercise support the potential use of mRNA profiling as an alternative......A collaborative exercise on mRNA profiling for the identification of blood was organized by the European DNA Profiling Group (EDNAP). Seven blood samples and one blood dilution series were analyzed by the participating laboratories for the reportedly blood-specific markers HBB, SPTB and PBGD, using...

  14. Reliability and Validity Assessment of a Linear Position Transducer

    Science.gov (United States)

    Garnacho-Castaño, Manuel V.; López-Lastra, Silvia; Maté-Muñoz, José L.

    2015-01-01

    The objectives of the study were to determine the validity and reliability of peak velocity (PV), average velocity (AV), peak power (PP) and average power (AP) measurements were made using a linear position transducer. Validity was assessed by comparing measurements simultaneously obtained using the Tendo Weightlifting Analyzer Systemi and T-Force Dynamic Measurement Systemr (Ergotech, Murcia, Spain) during two resistance exercises, bench press (BP) and full back squat (BS), performed by 71 trained male subjects. For the reliability study, a further 32 men completed both lifts using the Tendo Weightlifting Analyzer Systemz in two identical testing sessions one week apart (session 1 vs. session 2). Intraclass correlation coefficients (ICCs) indicating the validity of the Tendo Weightlifting Analyzer Systemi were high, with values ranging from 0.853 to 0.989. Systematic biases and random errors were low to moderate for almost all variables, being higher in the case of PP (bias ±157.56 W; error ±131.84 W). Proportional biases were identified for almost all variables. Test-retest reliability was strong with ICCs ranging from 0.922 to 0.988. Reliability results also showed minimal systematic biases and random errors, which were only significant for PP (bias -19.19 W; error ±67.57 W). Only PV recorded in the BS showed no significant proportional bias. The Tendo Weightlifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and estimating power in resistance exercises. The low biases and random errors observed here (mainly AV, AP) make this device a useful tool for monitoring resistance training. Key points This study determined the validity and reliability of peak velocity, average velocity, peak power and average power measurements made using a linear position transducer The Tendo Weight-lifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and power. PMID:25729300

  15. Core Muscle Activation in Suspension Training Exercises.

    Science.gov (United States)

    Cugliari, Giovanni; Boccia, Gennaro

    2017-02-01

    A quantitative observational laboratory study was conducted to characterize and classify core training exercises executed in a suspension modality on the base of muscle activation. In a prospective single-group repeated measures design, seventeen active male participants performed four suspension exercises typically associated with core training (roll-out, bodysaw, pike and knee-tuck). Surface electromyographic signals were recorded from lower and upper parts of rectus abdominis, external oblique, internal oblique, lower and upper parts of erector spinae muscles using concentric bipolar electrodes. The average rectified values of electromyographic signals were normalized with respect to individual maximum voluntary isometric contraction of each muscle. Roll-out exercise showed the highest activation of rectus abdominis and oblique muscles compared to the other exercises. The rectus abdominis and external oblique reached an activation higher than 60% of the maximal voluntary contraction (or very close to that threshold, 55%) in roll-out and bodysaw exercises. Findings from this study allow the selection of suspension core training exercises on the basis of quantitative information about the activation of muscles of interest. Roll-out and bodysaw exercises can be considered as suitable for strength training of rectus abdominis and external oblique muscles.

  16. Photovoltaic performance and reliability workshop

    Energy Technology Data Exchange (ETDEWEB)

    Mrig, L. [ed.

    1993-12-01

    This workshop was the sixth in a series of workshops sponsored by NREL/DOE under the general subject of photovoltaic testing and reliability during the period 1986--1993. PV performance and PV reliability are at least as important as PV cost, if not more. In the US, PV manufacturers, DOE laboratories, electric utilities, and others are engaged in the photovoltaic reliability research and testing. This group of researchers and others interested in the field were brought together to exchange the technical knowledge and field experience as related to current information in this evolving field of PV reliability. The papers presented here reflect this effort since the last workshop held in September, 1992. The topics covered include: cell and module characterization, module and system testing, durability and reliability, system field experience, and standards and codes.

  17. Validity of a heart rate monitor during work in the laboratory and on the Space Shuttle

    Science.gov (United States)

    Moore, A. D. Jr; Lee, S. M.; Greenisen, M. C.; Bishop, P.

    1997-01-01

    Accurate heart rate measurement during work is required for many industrial hygiene and ergonomics situations. The purpose of this investigation was to determine the validity of heart rate measurements obtained by a simple, lightweight, commercially available wrist-worn heart rate monitor (HRM) during work (cycle exercise) sessions conducted in the laboratory and also during the particularly challenging work environment of space flight. Three different comparisons were made. The first compared HRM data to simultaneous electrocardiogram (ECG) recordings of varying heart rates that were generated by an ECG simulator. The second compared HRM data to ECG recordings collected during work sessions of 14 subjects in the laboratory. Finally, ECG downlink and HRM data were compared in four astronauts who performed cycle exercise during space flight. The data were analyzed using regression techniques. The results were that the HRM recorded virtually identical heart rates compared with ECG recordings for the data set generated by an ECG simulator. The regression equation for the relationship between ECG versus HRM heart rate data during work in the laboratory was: ECG HR = 0.99 x (HRM) + 0.82 (r2 = 0.99). Finally, the agreement between ECG downlink data and HRM data during space flight was also very high, with the regression equation being: Downlink ECG HR = 1.05 x (HRM) -5.71 (r2 = 0.99). The results of this study indicate that the HRM provides accurate data and may be used to reliably obtain valid data regarding heart rate responses during work.

  18. Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise.

    Science.gov (United States)

    Hernando, David; Garatachea, Nuria; Almeida, Rute; Casajús, Jose A; Bailón, Raquel

    2018-03-01

    Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716-725, 2018-Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time-frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O2 above 60%).

  19. Virtual Simulations as Preparation for Lab Exercises: Assessing Learning of Key Laboratory Skills in Microbiology and Improvement of Essential Non-Cognitive Skills.

    Directory of Open Access Journals (Sweden)

    Guido Makransky

    Full Text Available To investigate if a virtual laboratory simulation (vLAB could be used to replace a face to face tutorial (demonstration to prepare students for a laboratory exercise in microbiology.A total of 189 students who were participating in an undergraduate biology course were randomly selected into a vLAB or demonstration condition. In the vLAB condition students could use a vLAB at home to 'practice' streaking out bacteria on agar plates in a virtual environment. In the demonstration condition students were given a live demonstration from a lab tutor showing them how to streak out bacteria on agar plates. All students were blindly assessed on their ability to perform the streaking technique in the physical lab, and were administered a pre and post-test to determine their knowledge of microbiology, intrinsic motivation to study microbiology, and self-efficacy in the field of microbiology prior to, and after the experiment.The results showed that there were no significant differences between the two groups on their lab scores, and both groups had similar increases in knowledge of microbiology, intrinsic motivation to study microbiology, as well as self-efficacy in the field of microbiology.Our data show that vLABs function just as well as face to face tutorials in preparing students for a physical lab activity in microbiology. The results imply that vLABs could be used instead of face to face tutorials, and a combination of virtual and physical lab exercises could be the future of science education.

  20. Development of low-level environmental sampling capabilities for uranium at Brazilian and Argentine laboratories by ABACC

    International Nuclear Information System (INIS)

    Guidicini, Olga Mafra; Hembree Junior, Doyle M.; Carter, Joel A.; Hayes, Susan; Whitaker, Michael; Olsen, Khris

    2003-01-01

    The Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC) with assistance from the U.S. Department of Energy (DOE) began a program to evaluate environmental sampling capabilities at laboratories in Argentina and Brazil in June 1998. The program included staff training conducted in South America and the United States. Several laboratory evaluation exercises were also conducted using standard swipe samples prepared by the International Atomic Energy Agency (IAEA) and a National Institute of Standards and Technology Standard Reference Material 1547, Peach Leaves. The results of these exercises demonstrated that several laboratories were capable of accurately determining the total uranium and uranium isotopic distribution in the peach leaves. To build on these successes, another exercise using standard swipe samples prepared by the IAEA was conducted. A total of 8 sets of 15 swipe samples were prepared and distributed to the six ABACC support laboratories and to two of DOE's Network of Analytical Laboratories (NWAL) that support IAEA's environmental sampling program Throughout this project, the ABACC laboratories have shown steady progress in contamination control and improvements to the accuracy and precision of their measurements. The results of the latest exercises demonstrate that ABACC now has support laboratories in both Argentina and Brazil that have the capability to measure both the amount and isotopic composition of uranium at levels expected in typical environmental samples (i.e., sub-microgram quantities). This presentation will discuss the final results for the exercise with uranium swipe samples and discuss future activities to develop measurement capabilities for total and isotopic plutonium in environmental samples. (author)

  1. 2014 NREL Photovoltaic Reliability Workshops | Photovoltaic Research | NREL

    Science.gov (United States)

    Failure Field Imaging Inverter Reliability Thin Film Technologies Packaging Materials and Accelerated . Introduction and Plenary Welcome-Bill Tumas, National Renewable Energy Laboratory (NREL) Welcome-Shubhra Bansal Reliability Analysis of Microinverters-Paul Parker, SolarBridge Technologies Back to top Thin Film

  2. Drama Drives a DNA Fingerprinting Lab Exercise.

    Science.gov (United States)

    Rubenstein, Elaine C.; And Others

    1996-01-01

    Presents a laboratory exercise for an intermediate cell and molecular biology course that uses a murder-mystery play. Provokes students to think critically about important issues in scientific methodology in general and DNA analysis in particular. (JRH)

  3. Introductory Bioinformatics Exercises Utilizing Hemoglobin and Chymotrypsin to Reinforce the Protein Sequence-Structure-Function Relationship

    Science.gov (United States)

    Inlow, Jennifer K.; Miller, Paige; Pittman, Bethany

    2007-01-01

    We describe two bioinformatics exercises intended for use in a computer laboratory setting in an upper-level undergraduate biochemistry course. To introduce students to bioinformatics, the exercises incorporate several commonly used bioinformatics tools, including BLAST, that are freely available online. The exercises build upon the students'…

  4. Reliability and Validity Assessment of a Linear Position Transducer

    Directory of Open Access Journals (Sweden)

    Manuel V. Garnacho-Castaño

    2015-03-01

    Full Text Available The objectives of the study were to determine the validity and reliability of peak velocity (PV, average velocity (AV, peak power (PP and average power (AP measurements were made using a linear position transducer. Validity was assessed by comparing measurements simultaneously obtained using the Tendo Weightlifting Analyzer Systemi and T-Force Dynamic Measurement Systemr (Ergotech, Murcia, Spain during two resistance exercises, bench press (BP and full back squat (BS, performed by 71 trained male subjects. For the reliability study, a further 32 men completed both lifts using the Tendo Weightlifting Analyzer Systemz in two identical testing sessions one week apart (session 1 vs. session 2. Intraclass correlation coefficients (ICCs indicating the validity of the Tendo Weightlifting Analyzer Systemi were high, with values ranging from 0.853 to 0.989. Systematic biases and random errors were low to moderate for almost all variables, being higher in the case of PP (bias ±157.56 W; error ±131.84 W. Proportional biases were identified for almost all variables. Test-retest reliability was strong with ICCs ranging from 0.922 to 0.988. Reliability results also showed minimal systematic biases and random errors, which were only significant for PP (bias -19.19 W; error ±67.57 W. Only PV recorded in the BS showed no significant proportional bias. The Tendo Weightlifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and estimating power in resistance exercises. The low biases and random errors observed here (mainly AV, AP make this device a useful tool for monitoring resistance training.

  5. Effect of Breakfast Omission on Energy Intake and Evening Exercise Performance.

    Science.gov (United States)

    Clayton, David J; Barutcu, Asya; Machin, Claire; Stensel, David J; James, Lewis J

    2015-12-01

    Breakfast omission may reduce daily energy intake. Exercising fasted impairs performance compared with exercising after breakfast, but the effect breakfast omission has on evening exercise performance is unknown. This study assessed the effect of omitting breakfast on evening exercise performance and within-day energy intake. Ten male, habitual breakfast eaters completed two trials in a randomized, counterbalanced order. Subjects arrived at the laboratory in an overnight-fasted state and either consumed or omitted a 733 ± 46 kcal (3095 ± 195 kJ) breakfast. Ad libitum energy intake was assessed at 4.5 h (lunch) and 11 h (dinner). At 9 h, subjects completed a 30-min cycling exercise at approximately 60% VO2peak, followed by a 30-min maximal cycling performance test. Food was not permitted for subjects once they left the laboratory after dinner until 0800 h the following morning. Acylated ghrelin, GLP-1(7-36), glucose, and insulin were assessed at 0, 4.5, and 9 h. Subjective appetite sensations were recorded throughout. Energy intake was 199 ± 151 kcal greater at lunch (P daily energy intake but may impair performance later that day, even after consuming lunch.

  6. Comparison of deep and superficial abdominal muscle activity between experienced Pilates and resistance exercise instructors and controls during stabilization exercise.

    Science.gov (United States)

    Moon, Ji-Hyun; Hong, Sang-Min; Kim, Chang-Won; Shin, Yun-A

    2015-06-01

    Pilates and resistance exercises are used for lumbar stabilization training. However, it is unclear which exercise is more effective for lumbar stabilization. In our study, we aimed to compare surface muscle activity and deep muscle thickness during relaxation and spinal stabilization exercise in experienced Pilates and resistance exercise instructors. This study is a retrospective case control study set in the Exercise Prescription Laboratory and Sports Medicine Center. The participants included Pilates instructors (mean years of experience, 3.20±1.76; n=10), resistance exercise instructors (mean years of experience, 2.53±0.63; n=10), and controls (n=10). The participants performed 4 different stabilization exercises: abdominal drawing-in maneuver, bridging, roll-up, and one-leg raise. During the stabilization exercises, surface muscle activity was measured with electromyography, whereas deep muscle thickness was measured by ultrasound imaging. During the 4 stabilization exercises, the thickness of the transverse abdominis (TrA) was significantly greater in the Pilates-trained group than the other 2 other groups. The internal oblique (IO) thickness was significantly greater in the Pilates- and resistance-trained group than the control group, during the 4 exercises. However, the surface muscle activities were similar between the groups. Both Pilates and resistance exercise instructors had greater activation of deep muscles, such as the TrA and IO, than the control subjects. Pilates and resistance exercise are both effective for increasing abdominal deep muscle thickness.

  7. Reliability modeling of Clinch River breeder reactor electrical shutdown systems

    International Nuclear Information System (INIS)

    Schatz, R.A.; Duetsch, K.L.

    1974-01-01

    The initial simulation of the probabilistic properties of the Clinch River Breeder Reactor Plant (CRBRP) electrical shutdown systems is described. A model of the reliability (and availability) of the systems is presented utilizing Success State and continuous-time, discrete state Markov modeling techniques as significant elements of an overall reliability assessment process capable of demonstrating the achievement of program goals. This model is examined for its sensitivity to safe/unsafe failure rates, sybsystem redundant configurations, test and repair intervals, monitoring by reactor operators; and the control exercised over system reliability by design modifications and the selection of system operating characteristics. (U.S.)

  8. The Unsupported Upper Limb Exercise Test in People Without Disabilities: Assessing the Within-Day Test-Retest Reliability and the Effects of Age and Gender.

    Science.gov (United States)

    Oliveira, Ana; Cruz, Joana; Jácome, Cristina; Marques, Alda

    2018-01-01

    Purpose: To estimate the within-day test-retest reliability and standard error of measurement (SEM) of the unsupported upper limb exercise test (UULEX) in adults without disabilities and to determine the effects of age and gender on performance of the UULEX. Method: A cross-sectional study was conducted with 100 adults without disabilities (44 men, mean age 44.2 [SD 26] y; 56 women, mean age 38.1 [SD 24.1] y). Participants performed three UULEX tests to establish within-day reliability, measured using an intra-class correlation coefficient (ICC) model 2 (two-way random effects) with a single rater (ICC[2,1]) and SEM. The effects of age and gender were examined using two-factor mixed-design analysis of variance (ANOVA) and one-way repeated-measures ANOVA. For analysis purposes, four sub-groups were created: younger adults, older adults, men, and women. Results: Excellent within-day reliability and a small SEM were found in the four sub-groups (younger adults: ICC[2,1]=0.88; 95% CI: 0.82, 0.92; SEM∼40 s; older adults: ICC[2,1]=0.82; 95% CI: 0.72, 0.90; SEM∼50 s; men: ICC[2,1]=0.93; 95% CI: 0.88, 0.96; SEM∼30 s; women: ICC[2,1]=0.85; 95% CI: 0.78, 0.91; SEM∼45 s). Younger adults took, on average, 308.24 seconds longer than older adults to perform the test; older adults performed significantly better on the third test ( p 0.05). Conclusion: The within-day test-retest reliability and SEM values of the UULEX may be used to define the magnitude of the error obtained with repeated measures. One UULEX test seems to be adequate for younger adults to achieve reliable results, whereas three tests seem to be needed for older adults.

  9. Reliability of blood pressure measurement and cardiovascular risk prediction

    NARCIS (Netherlands)

    van der Hoeven, N.V.

    2016-01-01

    High blood pressure is one of the leading risk factors for cardiovascular disease, but difficult to reliably assess because there are many factors which can influence blood pressure including stress, exercise or illness. The first part of this thesis focuses on possible ways to improve the

  10. Latinamerican Biological Dosimetry Network (LBDNET). International Biological Dosimetry intercomparison Program (exercise 2007-2008)

    International Nuclear Information System (INIS)

    Di Giorgio, Marina; Vallerga, Maria B.; Radl, A.; Taja, Maria R.

    2009-01-01

    This paper describes the International Biological Dosimetry Intercomparison Program (exercise 2007-2008) - developed within the framework of the IAEA regional project - RLA/9/054 (Establishment of national capabilities for response to radiological and nuclear emergency) whose general objectives are: assess reproducibility inter-laboratory; identify problems and provide the necessary modifications for collaborative work in accidental situations requiring activation of mutual assistance mechanisms which will form the basis of the Organization of LBDNET. This exercise involves the laboratories of the region: Argentina (laboratory support), Brazil, Chile, Cuba, Mexico, Peru and Uruguay and the laboratory of the Autonomous University of Barcelona-Espana (Joan Francesc Barquinero and staff). Finally, these countries will meet the next time for the drafting of a final report and later publication. (author)

  11. The Relative Contribution of Dietary Habits, Leisure-Time Exercise, Exercise Attitude, and Body Mass Index to Self-Rated Health among College Students in Taiwan.

    Science.gov (United States)

    Hsieh, Huey-Hong; Chang, Chia-Ming; Liu, Li-Wei; Huang, Hsiu-Chin

    2018-05-11

    Background : Self-rated health (SRH) is consistent with objective health status and can serve as a global measure of health status in the general population. The purpose of this study is to find the connections of dietary habits, leisure-time exercise, exercise attitude, and body mass index (BMI) to SRH among college students. Methods : The "dietary⁻exercise attitude and SRH" questionnaire was developed to investigate college students in Taiwan through the Internet. Partial least squares structural equation modeling (PLS-SEM) was used to test the relationship among them. Results : The reliability and validity were confirmed using PLS-SEM. The results found exercise habits, dietary habits, and BMI explained 26.5% of SRH. Poor dietary habits and being overweight led to bad health status (negative path coefficients to SRH). Additionally, the study found that positive exercise attitude had a positive relationship with exercise habits. Conclusions : Based on the results, college students should be well-informed of the potential threat of poor dietary habits and being overweight to health and should improve their attitude with respect to exercise so as to prevent overweight-related diseases.

  12. Bio-Oil Analysis Laboratory Procedures | Bioenergy | NREL

    Science.gov (United States)

    Bio-Oil Analysis Laboratory Procedures Bio-Oil Analysis Laboratory Procedures NREL develops laboratory analytical procedures (LAPs) for the analysis of raw and upgraded pyrolysis bio-oils. These standard procedures have been validated and allow for reliable bio-oil analysis. Procedures Determination

  13. Concepts in Physical Education with Laboratories and Experiments. Second Edition.

    Science.gov (United States)

    Corbin, Charles B.; And Others

    This text is designed for student use in introductory course of physical education at the college level and deals with the specific areas of physical activity, exercise, health, physical fitness, skill learning, and body mechanics. Twenty concepts and thirty accompanying laboratory exercises suitable for both men and women are presented. Two…

  14. Reliability issues in PACS

    Science.gov (United States)

    Taira, Ricky K.; Chan, Kelby K.; Stewart, Brent K.; Weinberg, Wolfram S.

    1991-07-01

    Reliability is an increasing concern when moving PACS from the experimental laboratory to the clinical environment. Any system downtime may seriously affect patient care. The authors report on the several classes of errors encountered during the pre-clinical release of the PACS during the past several months and present the solutions implemented to handle them. The reliability issues discussed include: (1) environmental precautions, (2) database backups, (3) monitor routines of critical resources and processes, (4) hardware redundancy (networks, archives), and (5) development of a PACS quality control program.

  15. The OMERACT Psoriatic Arthritis Magnetic Resonance Imaging Score (PsAMRIS) is reliable and sensitive to change: results from an OMERACT workshop

    DEFF Research Database (Denmark)

    Bøyesen, Pernille; McQueen, Fiona M; Gandjbakhch, Frédérique

    2011-01-01

    The aim of this multireader exercise was to assess the reliability and sensitivity to change of the psoriatic arthritis magnetic resonance imaging score (PsAMRIS) in PsA patients followed for 1 year.......The aim of this multireader exercise was to assess the reliability and sensitivity to change of the psoriatic arthritis magnetic resonance imaging score (PsAMRIS) in PsA patients followed for 1 year....

  16. Virtual Simulations as Preparation for Lab Exercises: Assessing Learning of Key Laboratory Skills in Microbiology and Improvement of Essential Non-Cognitive Skills

    DEFF Research Database (Denmark)

    Makransky, Guido; Warming Thisgaard, Malene; Gadegaard, Helen

    2016-01-01

    Objective To investigate if a virtual laboratory simulation (vLAB) could be used to replace a face to face tutorial (demonstration) to prepare students for a laboratory exercise in microbiology. Methods A total of 189 students who were participating in an undergraduate biology course were randomly...... selected into a vLAB or demonstration condition. In the vLAB condition students could use a vLAB at home to 'practice' streaking out bacteria on agar plates in a virtual environment. In the demonstration condition students were given a live demonstration from a lab tutor showing them how to streak out......-efficacy in the field of microbiology. Conclusion Our data show that vLABs function just as well as face to face tutorials in preparing students for a physical lab activity in microbiology. The results imply that vLABs could be used instead of face to face tutorials, and a combination of virtual and physical lab...

  17. Exercisers' identities and exercise dependence: the mediating effect of exercise commitment.

    Science.gov (United States)

    Lu, Frank Jing-Horng; Hsu, Eva Ya-Wen; Wang, Junn-Ming; Huang, Mei-Yao; Chang, Jo-Ning; Wang, Chien-Hsin

    2012-10-01

    The purpose of this study was to examine the associations of exercise identity, exercise commitment, exercise dependence, and, particularly, the mediating effects of exercise commitment on the relationship between exercise identity and exercise dependence. 253 Taiwanese regular exercisers completed measures, including the Exercise Dependence Scale-Revised, the Exercise Identity Scale, the Exercise Commitment Scale, and the Godin Leisure Time Exercise Questionnaire. Results showed that exercise identity, exercise dependence, and two types of exercise commitment were moderately to highly correlated. Furthermore, structural equation modelling indicated that a "have to" commitment partially mediated the relationship between exercise identity and exercise dependence. Based on the mediating role of a "have to" commitment, the findings are particularly informative to exercise instructors and for exercise program managers.

  18. Los Alamos National Laboratory A National Science Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Chadwick, Mark B. [Los Alamos National Laboratory

    2012-07-20

    Our mission as a DOE national security science laboratory is to develop and apply science, technology, and engineering solutions that: (1) Ensure the safety, security, and reliability of the US nuclear deterrent; (2) Protect against the nuclear threat; and (3) Solve Energy Security and other emerging national security challenges.

  19. Reliability and Engineering of Thin-Film Photovoltaic Modules. Research forum proceedings

    Science.gov (United States)

    Ross, R. G., Jr. (Editor); Royal, E. L. (Editor)

    1985-01-01

    A Research Forum on Reliability and Engineering of Thin Film Photovoltaic Modules, under sponsorship of the Jet Propulsion Laboratory's Flat Plate Solar Array (FSA) Project and the U.S. Department of Energy, was held in Washington, D.C., on March 20, 1985. Reliability attribute investigations of amorphous silicon cells, submodules, and modules were the subjects addressed by most of the Forum presentations. Included among the reliability research investigations reported were: Arrhenius-modeled accelerated stress tests on a Si cells, electrochemical corrosion, light induced effects and their potential effects on stability and reliability measurement methods, laser scribing considerations, and determination of degradation rates and mechanisms from both laboratory and outdoor exposure tests.

  20. Worldwide Laboratory Comparison on the Determination of Trace Elements in IAEA-452 Biota Sample

    International Nuclear Information System (INIS)

    2012-01-01

    The Marine Environmental Studies Laboratory (MESL) of the International Atomic Energy Agency's Environment Laboratories (IAEA-NAEL) has the programmatic responsibility to provide assistance to Member States' laboratories in maintaining and improving the reliability of analytical measurement results, both in trace elements and organic pollutants. This is accomplished through the provision of reference materials of marine origin, validated analytical procedures, training in the implementation of internal quality control, and through the evaluation of measurement performance by the organization of worldwide and regional interlaboratory comparison exercises. For nearly thirty years, the MESL has conducted worldwide laboratory performance studies, also known as interlaboratory comparison. The results have been used to evaluate laboratory performance with respect to a wide range of organic and inorganic pollutants, including methyl mercury. This work has been conducted in collaboration with the UNEP Regional Seas Programme. The goal of interlaboratory comparison is to demonstrate the measurement capabilities of laboratories participating in interlaboratory comparisons (ILCs) and proficiency tests (PTs). The results from ILCs or PTs are of crucial interest for laboratories as these provide clear information of its measurement capabilities. It should be pointed out that the participation is either voluntary or forced by external requirements (e.g. legal, accreditation, control bodies). NAEL's interlaboratory comparison (ILC) and proficiency test (PT) schemes involve comparison of participant's results with an assigned value, which usually is delivered as a consensus value from the overall population of test results. Those exercises are designed to monitor and demonstrate the performance and analytical capabilities of the participating laboratories, and to identify gaps and problem areas where further development is needed. Continued membership has benefits in training and

  1. CENDOS joint neutron irradiation exercise -results from Berkeley Nuclear Laboratories

    International Nuclear Information System (INIS)

    Harvey, J.R.; Weeks, A.R.

    1985-01-01

    A brief description is given of the use of CR-39 in an intercomparison exercise on personnel neutron dosemeters based on proton sensitive track detectors. Details of the etching, assessment and results are presented and discussed in terms of measured dosemeter sensitivities. A description is also given of the reading system used which consists of a videcon tube, television monitor and image analysis system. (UK)

  2. Determination of the exercise intensity that elicits maximal fat oxidation in individuals with obesity

    DEFF Research Database (Denmark)

    Jørgensen, Sune Dandanell; Præst, Charlotte Boslev; Søndergård, Stine Dam

    2017-01-01

    . The graded exercise protocol was validated against a short continuous exercise (SCE) protocol, in which FatMax was determined from fat oxidation at rest and during 10-min continuous exercise at 35, 50 and 65% of maximal oxygen uptake (VO2max). Intraclass and Pearson correlation coefficients between......2max with the graded and the SCE protocol, respectively. In conclusion, there was a high-excellent correlation and a low CV between the two protocols, suggesting that the graded exercise protocol has a high inter-method reliability. However, considerable intra-individual variation and a trend...

  3. Psychometric evaluation of the Korean Version of the Self-Efficacy for Exercise Scale for older adults.

    Science.gov (United States)

    Choi, Mona; Ahn, Sangwoo; Jung, Dukyoo

    2015-01-01

    We evaluated the psychometric properties of the Korean version of the Self-Efficacy for Exercise Scale (SEE-K). The SEE-K consists of nine items and was translated into Korean using the forward-backward translation method. We administered it to 212 community-dwelling older adults along with measures of outcome expectation for exercise, quality of life, and physical activity. The validity was determined using confirmatory factor analysis and Rasch analysis with INFIT and OUTFIT statistics, which showed acceptable model fit. The concurrent validity was confirmed according to positive correlations between the SEE-K, outcome expectation for exercise, and quality of life. Furthermore, the high physical activity group had higher SEE-K scores. Finally, the reliability of the SEE-K was deemed acceptable based on Cronbach's alpha, coefficients of determination, and person and item separation indices with reliability. Thus, the SEE-K appears to have satisfactory validity and reliability among older adults in South Korea. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Professor Created On-line Biology Laboratory Course

    Science.gov (United States)

    Bowman, Arthur W.

    2010-01-01

    This paper will share the creation, implementation, and modification of an online college level general biology laboratory course offered for non-science majors as a part of a General Education Curriculum. The ability of professors to develop quality online laboratories will address a growing need in Higher Education as more institutions combine course sections and look for suitable alternative course delivery formats due to declining departmental budgets requiring reductions in staffing, equipment, and supplies. Also, there is an equal or greater need for more professors to develop the ability to create online laboratory experiences because many of the currently available online laboratory course packages from publishers do not always adequately parallel on-campus laboratory courses, or are not as aligned with the companion lecture sections. From a variety of scientific simulation and animation web sites, professors can easily identify material that closely fit the specific needs of their courses, instructional environment, and students that they serve. All too often, on-campus laboratory courses in the sciences provide what are termed confirmation experiences that do NOT allow students to experience science as would be carried out by scientists. Creatively developed online laboratory experiences can often provide the type of authentic investigative experiences that are not possible on-campus due to the time constraints of a typical two-hour, once-per-week-meeting laboratory course. In addition, online laboratory courses can address issues related to the need for students to more easily complete missing laboratory assignments, and to have opportunities to extend introductory exercises into more advanced undertakings where a greater sense of scientific discovery can be experienced. Professors are strongly encourages to begin creating online laboratory exercises for their courses, and to consider issues regarding assessment, copyrights, and Intellectual Property

  5. Changes in muscle thickness after exercise and biofeedback in people with low back pain.

    Science.gov (United States)

    Partner, Shandi L; Sutherlin, Mark Alan; Acocello, Shellie; Saliba, Susan A; Magrum, Eric M; Hart, Joe M

    2014-11-01

    Individuals with low back pain (LBP) have reduced function of the transversus abdominis (TrA) and lumbar multifidus (LM) muscles. Biofeedback during exercise may increase the ability to contract the TrA and LM muscles compared with exercise alone. To compare TrA preferential activation ratio (PAR) and the percent change in LM-muscle thickness in patients with LBP history before and after exercise with or without biofeedback. Controlled laboratory study. University research laboratory. 20 LBP individuals, 10 exercise alone and 10 exercise with biofeedback. Patients were allotted to tabletop exercises in isolation or tabletop exercises with visual, auditory, and tactile biofeedback. TrA PAR and percent change in LM-muscle thickness. There were no differences between groups at baseline (all P > .05). Nonparametric statistics showed decreased resting muscle thickness for total lateral abdominal-wall muscles (P = .007) but not TrA (P = .410) or LM (P = .173). Percent TrA thickness increased from table to standing positions before (P = .006) and after exercise (P = .009). TrA PAR increased after exercise (pre 0.01 ± 0.02, post 0.03 ± 0.04, P = .033) for all patients and for exercise with biofeedback (pre 0.02 ± 0.01, post 0.03 ± 0.01, P = .037) but not for exercise alone (pre 0.01 ± 0.02, post 0.02 ± 0.05, P = .241). No group differences were observed for TrA PAR before (exercise 0.01 ± 0.02, exercise with biofeedback 0.02 ± 0.01, P = .290) or after exercise (exercise 0.02 ± 0.05, exercise with biofeedback 0.03 ± 0.01, P = .174). There were no group differences in LM percent change before exercise (P = .999) or after exercise (P = .597). In addition, no changes were observed in LM percent change as a result of exercise among all participants (P = .391) or for each group (exercise P = .508, exercise with biofeedback P = .575). TrA PAR increased after a single session of exercises, whereas no thickness changes occurred in LM.

  6. physiological effects of the amphetamines during exercise

    African Journals Online (AJOL)

    PHYSIOLOGICAL EFFECTS OF THE AMPHETAMINES DURING EXERCISE* c. H. WYNDHAM, G. G. ROGERS, A. J. S. BENADE AND N. B. STRYDOM, Human Sciences Laboratory, Chamber of. Mines of SOUTh Africa, Johannesburg. SUMMARY. Oxygen consumption, heart rate, minute ventilation and blood lactate were ...

  7. Results of the ninth exercise of intercomparison in services of personal dosimetry in Argentina Republic in the year of 2011

    International Nuclear Information System (INIS)

    Ferrufino, G.A.; Discacciatti, P.A.; Lopez, F.O.

    2013-01-01

    In this paper we present the results of the ninth intercomparison exercise personal dosimetry services, conducted by the Nuclear Regulatory Authority in 2011. The exercise was designed to evaluate the performance of laboratories providing personal dosimetry services in Argentina , for X-rays and gamma radiation fields . This exercise was organized by the Nuclear Regulatory Authority with the Ministry of Health of the Nation and the Regional Reference Laboratory Centre for Dosimetry of the National Atomic Energy Commission . The irradiations were carried out in full accordance with ISO 4037-3 . Participates all private companies in Argentina serving all personal dosimetry laboratories and agencies, provincial and national. Furthermore, the Laboratories from Cuba, Brazil and Uruguay also participate. The performance of a laboratory is considered acceptable if it meets the criteria established in the IRAM- ISO 14146 , which states: 'It is recognized that at most, one-tenth of dosimeters irradiated to exceed the limits'. Of all of the laboratories that participated , 68% reported their results within the acceptance criteria above. The primary objective of this intercomparison exercise is to provide an objective tool to evaluate the ability of personnel dosimetry services. (author)

  8. Intercomparison programs - a tool for the implementation of a quality assurance program in bioassay

    International Nuclear Information System (INIS)

    Mesquita, Sueli A. de; Sousa, Wanderson O.; Juliao, Ligia M.Q.C.; Santos, Maristela S.; Fernandes, Paulo C.P.

    2009-01-01

    In vitro bioassay laboratories need to have means to demonstrate that they are technically competent, operate an effective quality system, and are able to generate technically valid calibration and test results. The reliability of the results of measurements has a high influence on the reliability of the dose assessment. Inter-laboratory tests are one of the tools for assessing the analytical consistency of in vitro bioassay laboratories. The intercomparison exercises provide an opportunity to compare radiochemistry techniques for in vitro analysis of biological samples. The in vitro Laboratory of the Instituto de Radioprotecao e Dosimetria has therefore participated in the intercomparison exercises sponsored by PROCORAD, ARCAL and IAEA since 1998. The intercomparison exercises comprise measurements of gamma and beta emitters in urine samples and alpha emitters in urine and faecal samples. This paper presents the performance of the IRD in vitro bioassay laboratory in the past intercomparisons. The results demonstrate that in vitro laboratory is able to generate technically valid results, which also guarantee the support for a quality assurance program and accreditation by competent organism in Brazil. (author)

  9. Battery Test Facility- Electrochemical Analysis and Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrochemical Analysis and Diagnostics Laboratory (EADL) provides battery developers with reliable, independent, and unbiased performance evaluations of their...

  10. Exercise addiction- diagnosis, bio-psychological mechanisms and treatment issues.

    Science.gov (United States)

    Weinstein, Aviv; Weinstein, Yitzhak

    2014-01-01

    Exercise and sports activity are beneficial both physically and psychologically but excessive exercise may have adverse physiological and psychological effects. There are methodological issues in the definition, diagnosis and etiology of exercise addiction. Several questionnaires and diagnostic tools have been developed and validated and they show high validity and reliability. Exercise addiction has been suggested as having an obsessive-compulsive dimension as well as rewarding aspects that may include it among the behavioral addictions. Biological studies show that in rodents, exercise such as wheel running activates the dopamine reward system and thus contributing to stress reduction. Further evidence suggests that running is associated with endorphins and cannabinoids thus explaining the "runners high" or euphoric feelings that may lead to exercise addiction. Genetic studies suggest that genes which control preference for drugs also control the preference for naturally rewarding behaviors such as exercise. Psychological studies also explain exercise addiction in terms of reward, habituation, social support, stress-relief, avoidance of withdrawal and reduction of anxiety. It has been suggested that exercise addiction is a part of a continuum of sportive activity that develops in stages from the recreational exercise to at-risk exercise, problematic exercise and finally into exercise addiction. Assessment and treatment should take into account the various stages of exercise addiction development, its comorbidity with other psychiatric disorders such as eating disorders or substance use and alcohol disorders. Treatment approaches for exercise addiction are based on the cognitive-behavioral approach but little is known about their effectiveness. A single-case study shows promise of pharmacological treatment for exercise addiction and further studies are required. This review summarizes diagnostic and phenomenology of exercise addiction with emphasis on

  11. The behaviour of satellite cells in response to exercise: what have we learned from human studies?

    DEFF Research Database (Denmark)

    Kadi, Fawzi; Olsen, Steen Schytte

    2005-01-01

    Understanding the complex role played by satellite cells in the adaptive response to exercise in human skeletal muscle has just begun. The development of reliable markers for the identification of satellite cell status (quiescence/activation/proliferation) is an important step towards the underst......Understanding the complex role played by satellite cells in the adaptive response to exercise in human skeletal muscle has just begun. The development of reliable markers for the identification of satellite cell status (quiescence/activation/proliferation) is an important step towards...

  12. Activity-based costing methodology as tool for costing in hematopathology laboratory.

    Science.gov (United States)

    Gujral, Sumeet; Dongre, Kanchan; Bhindare, Sonal; Subramanian, P G; Narayan, Hkv; Mahajan, Asim; Batura, Rekha; Hingnekar, Chitra; Chabbria, Meenu; Nair, C N

    2010-01-01

    Cost analysis in laboratories represents a necessary phase in their scientific progression. To calculate indirect cost and thus total cost per sample of various tests at Hematopathology laboratory (HPL). Activity-based costing (ABC) method is used to calculate per cost test of the hematopathology laboratory. Information is collected from registers, purchase orders, annual maintenance contracts (AMCs), payrolls, account books, hospital bills and registers along with informal interviews with hospital staff. Cost per test decreases as total number of samples increases. Maximum annual expense at the HPL is on reagents and consumables followed by manpower. Cost per test is higher for specialized tests which interpret morphological or flow data and are done by a pathologist. Despite several limitations and assumptions, this was an attempt to understand how the resources are consumed in a large size government-run laboratory. The rate structure needs to be revised for most of the tests, mainly for complete blood counts (CBC), bone marrow examination, coagulation tests and Immunophenotyping. This costing exercise is laboratory specific and each laboratory needs to do its own costing. Such an exercise may help a laboratory redesign its costing structure or at least understand the economics involved in the laboratory management.

  13. Self-determined to exercise? Leisure-time exercise behavior, exercise motivation, and exercise dependence in youth.

    Science.gov (United States)

    Symons Downs, Danielle; Savage, Jennifer S; DiNallo, Jennifer M

    2013-02-01

    Scant research has examined the determinants of primary exercise dependence symptoms in youth. Study purposes were to examine sex differences across leisure-time exercise behavior, motivation, and primary exercise dependence symptoms in youth and the extent to which exercise behavior and motivation predicted exercise dependence within the Self-Determination Theory framework. Adolescents (N = 805; mean age = 15 years; 46% girls) completed measures of exercise behavior, motivation, and exercise dependence in health/PE classes. One-way ANOVA revealed boys scored higher than girls on leisure-time exercise behavior, exercise dependence symptoms, and most of the exercise motivation subscales. Hierarchical regression analyses indicated a) sex, exercise behavior, motivation, and their interaction terms explained 39% of the variance in primary exercise dependence; b) Integrated Regulation and Introjected Regulation were important determinants of exercise dependence; and c) sex moderated the contributions of External Regulation for predicting exercise dependence such that boys in the high and low external regulation groups had higher symptoms than girls in the high and low external regulation groups. These preliminary findings support the controlled dimensions of Integrated Regulation (boys, girls), Introjected Regulation (boys, girls), and External Regulation (boys only) are important determinants of primary exercise dependence symptoms.

  14. IAEA AQCS catalogue for reference materials and intercomparison exercises 1998/1999

    International Nuclear Information System (INIS)

    1999-01-01

    Fore more than thirty years the International Atomic Energy Agency (IAEA), through its Analytical Quality Control Services (AQCS) programme, has been assisting Member States' laboratories to maintain and improve the reliability of their analyses by organizing intercomparison exercises and by preparing and distributing biological, environmental and marine reference materials. The catalogue consists principally of two parts: The list of all available IAEA reference materials grouped into five categories: reference materials for radionuclides; reference materials for trace, minor and major elements, including oxides; reference materials for stable isotopes; reference materials for organic contaminants and methyl mercury containing materials. Lists of all available IAEA reference materials sorted by analytes. In addition information on recommended half-life data and suppliers of radioactive sources is provided. Planned intercomparisons are advertised and request forms for participation in intercomparisons are included. Forms for ordering reference materials, quality control spectra for gamma-spectrometry on diskettes and AQCS related publications are also provided

  15. The Relative Contribution of Dietary Habits, Leisure-Time Exercise, Exercise Attitude, and Body Mass Index to Self-Rated Health among College Students in Taiwan

    Science.gov (United States)

    Hsieh, Huey-Hong; Chang, Chia-Ming; Liu, Li-Wei; Huang, Hsiu-Chin

    2018-01-01

    Background: Self-rated health (SRH) is consistent with objective health status and can serve as a global measure of health status in the general population. The purpose of this study is to find the connections of dietary habits, leisure-time exercise, exercise attitude, and body mass index (BMI) to SRH among college students. Methods: The “dietary–exercise attitude and SRH” questionnaire was developed to investigate college students in Taiwan through the Internet. Partial least squares structural equation modeling (PLS-SEM) was used to test the relationship among them. Results: The reliability and validity were confirmed using PLS-SEM. The results found exercise habits, dietary habits, and BMI explained 26.5% of SRH. Poor dietary habits and being overweight led to bad health status (negative path coefficients to SRH). Additionally, the study found that positive exercise attitude had a positive relationship with exercise habits. Conclusions: Based on the results, college students should be well-informed of the potential threat of poor dietary habits and being overweight to health and should improve their attitude with respect to exercise so as to prevent overweight-related diseases. PMID:29751682

  16. The Relative Contribution of Dietary Habits, Leisure-Time Exercise, Exercise Attitude, and Body Mass Index to Self-Rated Health among College Students in Taiwan

    Directory of Open Access Journals (Sweden)

    Huey-Hong Hsieh

    2018-05-01

    Full Text Available Background: Self-rated health (SRH is consistent with objective health status and can serve as a global measure of health status in the general population. The purpose of this study is to find the connections of dietary habits, leisure-time exercise, exercise attitude, and body mass index (BMI to SRH among college students. Methods: The “dietary–exercise attitude and SRH” questionnaire was developed to investigate college students in Taiwan through the Internet. Partial least squares structural equation modeling (PLS-SEM was used to test the relationship among them. Results: The reliability and validity were confirmed using PLS-SEM. The results found exercise habits, dietary habits, and BMI explained 26.5% of SRH. Poor dietary habits and being overweight led to bad health status (negative path coefficients to SRH. Additionally, the study found that positive exercise attitude had a positive relationship with exercise habits. Conclusions: Based on the results, college students should be well-informed of the potential threat of poor dietary habits and being overweight to health and should improve their attitude with respect to exercise so as to prevent overweight-related diseases.

  17. Special nuclear materials cutoff exercise: Issues and lessons learned. Volume 1: Summary of exercise

    International Nuclear Information System (INIS)

    Libby, R.A.; Davis, C.; Segal, J.E.; Stanbro, W.D.

    1995-08-01

    In a September 1993 address to the United Nations General Assembly, President Clinton announced a new nonproliferation and export control policy that established a framework for US efforts to prevent the proliferation of weapons of mass destruction. The new policy proposed that the US undertake a comprehensive approach to the growing accumulation of fissile material. One of the key elements was for the US to support a special nuclear materials (SNM) multilateral convention prohibiting the production of highly enriched uranium (HEU) or plutonium for nuclear explosives purposes or outside of international safeguards. This policy is often referred to as the President's Cutoff Initiative or the Fissile Material Cutoff Treaty (FMCT). Because both the US Department of Energy (DOE) and foreign reprocessing facilities similar to PUREX will likely to be inspected under a FMCT, the DOE Office of Arms Control and Nonproliferation, Negotiations and Analysis Division (DOE/NN-41) tasked Pacific Northwest Laboratory (PNL) to perform an information gathering exercise, the PUREX Exercise, using the Plutonium-Uranium Extraction (PUREX) Plant located on the Hanford Site in Washington State. PUREX is a former production reactor fuel reprocessing plant currently undergoing a transition to a ''decontamination and decommissioning (D ampersand D) ready'' mode. The PUREX Exercise was conducted March 29--30, 1994, to examine aspects of the imposition of several possible cutoff regimes and to study verification of non-production of SNM for nuclear weapons purposes or outside of safeguards. A follow-up activity to further examine various additional verification regimes was held at Los Alamos National Laboratory (LANL) on May 10, 1994

  18. Determination of the exercise intensity that elicits maximal fat oxidation in individuals with obesity.

    Science.gov (United States)

    Dandanell, Sune; Præst, Charlotte Boslev; Søndergård, Stine Dam; Skovborg, Camilla; Dela, Flemming; Larsen, Steen; Helge, Jørn Wulff

    2017-04-01

    Maximal fat oxidation (MFO) and the exercise intensity that elicits MFO (Fat Max ) are commonly determined by indirect calorimetry during graded exercise tests in both obese and normal-weight individuals. However, no protocol has been validated in individuals with obesity. Thus, the aims were to develop a graded exercise protocol for determination of Fat Max in individuals with obesity, and to test validity and inter-method reliability. Fat oxidation was assessed over a range of exercise intensities in 16 individuals (age: 28 (26-29) years; body mass index: 36 (35-38) kg·m -2 ; 95% confidence interval) on a cycle ergometer. The graded exercise protocol was validated against a short continuous exercise (SCE) protocol, in which Fat Max was determined from fat oxidation at rest and during 10 min of continuous exercise at 35%, 50%, and 65% of maximal oxygen uptake. Intraclass and Pearson correlation coefficients between the protocols were 0.75 and 0.72 and within-subject coefficient of variation (CV) was 5 (3-7)%. A Bland-Altman plot revealed a bias of -3% points of maximal oxygen uptake (limits of agreement: -12 to 7). A tendency towards a systematic difference (p = 0.06) was observed, where Fat Max occurred at 42 (40-44)% and 45 (43-47)% of maximal oxygen uptake with the graded and the SCE protocol, respectively. In conclusion, there was a high-excellent correlation and a low CV between the 2 protocols, suggesting that the graded exercise protocol has a high inter-method reliability. However, considerable intra-individual variation and a trend towards systematic difference between the protocols reveal that further optimization of the graded exercise protocol is needed to improve validity.

  19. Intrarater Reliability of Muscle Strength and Hamstring to Quadriceps Strength Imbalance Ratios During Concentric, Isometric, and Eccentric Maximal Voluntary Contractions Using the Isoforce Dynamometer.

    Science.gov (United States)

    Mau-Moeller, Anett; Gube, Martin; Felser, Sabine; Feldhege, Frank; Weippert, Matthias; Husmann, Florian; Tischer, Thomas; Bader, Rainer; Bruhn, Sven; Behrens, Martin

    2017-08-17

    To determine intrasession and intersession reliability of strength measurements and hamstrings to quadriceps strength imbalance ratios (H/Q ratios) using the new isoforce dynamometer. Repeated measures. Exercise science laboratory. Thirty healthy subjects (15 females, 15 males, 27.8 years). Coefficient of variation (CV) and intraclass correlation coefficients (ICC) were calculated for (1) strength parameters, that is peak torque, mean work, and mean power for concentric and eccentric maximal voluntary contractions; isometric maximal voluntary torque (IMVT); rate of torque development (RTD), and (2) H/Q ratios, that is conventional concentric, eccentric, and isometric H/Q ratios (Hcon/Qcon at 60 deg/s, 120 deg/s, and 180 deg/s, Hecc/Qecc at -60 deg/s and Hiso/Qiso) and functional eccentric antagonist to concentric agonist H/Q ratios (Hecc/Qcon and Hcon/Qecc). High reliability: CV 0.90; moderate reliability: CV between 10% and 20%, ICC between 0.80 and 0.90; low reliability: CV >20%, ICC Strength parameters: (a) high intrasession reliability for concentric, eccentric, and isometric measurements, (b) moderate-to-high intersession reliability for concentric and eccentric measurements and IMVT, and (c) moderate-to-high intrasession reliability but low intersession reliability for RTD. (2) H/Q ratios: (a) moderate-to-high intrasession reliability for conventional ratios, (b) high intrasession reliability for functional ratios, (c) higher intersession reliability for Hcon/Qcon and Hiso/Qiso (moderate to high) than Hecc/Qecc (low to moderate), and (d) higher intersession reliability for conventional H/Q ratios (low to high) than functional H/Q ratios (low to moderate). The results have confirmed the reliability of strength parameters and the most frequently used H/Q ratios.

  20. Reliable predictions of waste performance in a geologic repository

    International Nuclear Information System (INIS)

    Pigford, T.H.; Chambre, P.L.

    1985-08-01

    Establishing reliable estimates of long-term performance of a waste repository requires emphasis upon valid theories to predict performance. Predicting rates that radionuclides are released from waste packages cannot rest upon empirical extrapolations of laboratory leach data. Reliable predictions can be based on simple bounding theoretical models, such as solubility-limited bulk-flow, if the assumed parameters are reliably known or defensibly conservative. Wherever possible, performance analysis should proceed beyond simple bounding calculations to obtain more realistic - and usually more favorable - estimates of expected performance. Desire for greater realism must be balanced against increasing uncertainties in prediction and loss of reliability. Theoretical predictions of release rate based on mass-transfer analysis are bounding and the theory can be verified. Postulated repository analogues to simulate laboratory leach experiments introduce arbitrary and fictitious repository parameters and are shown not to agree with well-established theory. 34 refs., 3 figs., 2 tabs

  1. Mobile Radiological Laboratories Intercomparison Measurements - Chernobyl

    International Nuclear Information System (INIS)

    Martincic, R.; Glavic-Cindro, D.; Korun, M.; Pucelj, B.; Vodenik, B.

    2001-01-01

    Full text: In last decade different institutions in European countries have organised periodic intercomparison exercises of mobile radiological laboratories to improve the preparedness of emergency monitoring teams. The 12th Regular Workshop on Mobile Radiological Laboratories was held in Exclusion Zone of the Chernobyl NPP, Ukraine from September 13 to September 18, 1999 under the acronym MORAL-12. The European Centre of Technological Safety (TESEC), Kiev, Ukraine and J. Stefan Institute, Ljubljana, Slovenia organised Intercomparison Measurements 99 jointly under the auspices of the International Atomic Energy Agency (IAEA). Nineteen teams from 9 countries and IAEA participated in the Workshop. Six field and personal and equipment contamination control exercises were prepared and conducted at two measuring sites with very different ambient dose rate levels. The Workshop pointed out that such exercises are very valuable for rapid, efficient and harmonised emergency response in case of nuclear or radiological emergency. The teams had an opportunity to test their ability to perform field measurements in the contaminated environment, and to report results on the spot, as well as to test their emergency preparedness and persistence. They gained new experiences for fieldwork under stress conditions. An overview and results of these intercomparison measurements are presented and lessons learned are discussed. (author)

  2. Enhanced Training for Cyber Situational Awareness in Red versus Blue Team Exercises

    Energy Technology Data Exchange (ETDEWEB)

    Carbajal, Armida J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Human Factors and Statistics; Stevens-Adams, Susan Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Risk and Reliability Analysis; Silva, Austin Ray [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Cognitive Modeling; Nauer, Kevin S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Cyber Security Technologies; Anderson, Benjamin Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Assurance Technologies and Assessment; Forsythe, James Chris [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Cognitive Modeling

    2012-09-01

    This report summarizes research conducted through the Sandia National Laboratories Enhanced Training for Cyber Situational Awareness in Red Versus Blue Team Exercises Laboratory Directed Research and Development project. The objective of this project was to advance scientific understanding concerning how to best structure training for cyber defenders. Two modes of training were considered. The baseline training condition (Tool-Based training) was based on current practices where classroom instruction focuses on the functions of a software tool with various exercises in which students apply those functions. In the second training condition (Narrative-Based training), classroom instruction addressed software functions, but in the context of adversary tactics and techniques. It was hypothesized that students receiving narrative-based training would gain a deeper conceptual understanding of the software tools and this would be reflected in better performance within a red versus blue team exercise.

  3. Incorporating a Watershed-Based Summary Field Exercise into an Introductory Hydrogeology Course

    Science.gov (United States)

    Fryar, Alan E.; Thompson, Karen E.; Hendricks, Susan P.; White, David S.

    2010-01-01

    We have developed and implemented a summary field exercise for an introductory hydrogeology course without a laboratory section. This exercise builds on lectures and problem sets that use pre-existing field data. During one day in April, students measure hydraulic heads, stream and spring flow, and stream-bed seepage within the rural watershed of…

  4. An "in Silico" DNA Cloning Experiment for the Biochemistry Laboratory

    Science.gov (United States)

    Elkins, Kelly M.

    2011-01-01

    This laboratory exercise introduces students to concepts in recombinant DNA technology while accommodating a major semester project in protein purification, structure, and function in a biochemistry laboratory for junior- and senior-level undergraduate students. It is also suitable for forensic science courses focused in DNA biology and advanced…

  5. ACUTE PSYCHOLOGICAL BENEFITS OF EXERCISE PERFORMED AT SELF-SELECTED WORKLOADS: IMPLICATIONS FOR THEORY AND PRACTICE

    OpenAIRE

    Attila Szabo

    2003-01-01

    Given that most studies to date examined the connection between exercise and affect without considering the participants’ preferred exercise workload, in this research the affective-benefits of jogging or running at a participant-selected pace were investigated in a pilot field and a laboratory experiment. Ninety-six male and female students (19.5 yrs) took part in the pilot field experiment whereas 32 women (20.3 yrs) completed the laboratory experiment. In both experiments, the participants...

  6. Demonstration Exercise of a Validated Sample Collection Method for Powders Suspected of Being Biological Agents in Georgia 2006

    International Nuclear Information System (INIS)

    Marsh, B.

    2007-01-01

    August 7, 2006 the state of Georgia conducted a collaborative sampling exercise between the Georgia National Guard 4th Civil Support Team Weapons of Mass Destruction (CST-WMD) and the Georgia Department of Human Resources Division of Public Health demonstrating a recently validated bulk powder sampling method. The exercise was hosted at the Federal Law Enforcement Training Center (FLETC) at Glynn County, Georgia and involved the participation of the Georgia Emergency Management Agency (GEMA), Georgia National Guard, Georgia Public Health Laboratories, the Federal Bureau of Investigation Atlanta Office, Georgia Coastal Health District, and the Glynn County Fire Department. The purpose of the exercise was to demonstrate a recently validated national sampling standard developed by the American Standards and Test Measures (ASTM) International; ASTM E2458 S tandard Practice for Bulk Sample Collection and Swab Sample Collection of Visible Powders Suspected of Being Biological Agents from Nonporous Surfaces . The intent of the exercise was not to endorse the sampling method, but to develop a model for exercising new sampling methods in the context of existing standard operating procedures (SOPs) while strengthening operational relationships between response teams and analytical laboratories. The exercise required a sampling team to respond real-time to an incident cross state involving a clandestine bio-terrorism production lab found within a recreational vehicle (RV). Sample targets consisted of non-viable gamma irradiated B. anthracis Sterne spores prepared by Dugway Proving Ground. Various spore concentration levels were collected by the ASTM method, followed by on- and off-scene analysis utilizing the Center for Disease Control (CDC) Laboratory Response Network (LRN) and National Guard Bureau (NGB) CST mobile Analytical Laboratory Suite (ALS) protocols. Analytical results were compared and detailed surveys of participant evaluation comments were examined. I will

  7. Validity and reliability of a field technique for sweat Na+ and K+ analysis during exercise in a hot-humid environment.

    Science.gov (United States)

    Baker, Lindsay B; Ungaro, Corey T; Barnes, Kelly A; Nuccio, Ryan P; Reimel, Adam J; Stofan, John R

    2014-01-01

    Abstract This study compared a field versus reference laboratory technique for extracting (syringe vs. centrifuge) and analyzing sweat [Na(+)] and [K(+)] (compact Horiba B-722 and B-731, HORIBA vs. ion chromatography, HPLC) collected with regional absorbent patches during exercise in a hot-humid environment. Sweat samples were collected from seven anatomical sites on 30 athletes during 1-h cycling in a heat chamber (33°C, 67% rh). Ten minutes into exercise, skin was cleaned/dried and two sweat patches were applied per anatomical site. After removal, one patch per site was centrifuged and sweat was analyzed with HORIBA in the heat chamber (CENTRIFUGE HORIBA) versus HPLC (CENTRIFUGE HPLC). Sweat from the second patch per site was extracted using a 5-mL syringe and analyzed with HORIBA in the heat chamber (SYRINGE HORIBA) versus HPLC (SYRINGE HPLC). CENTRIFUGE HORIBA, SYRINGE HPLC, and SYRINGE HORIBA were highly related to CENTRIFUGE HPLC ([Na(+)]: ICC = 0.96, 0.94, and 0.93, respectively; [K(+)]: ICC = 0.87, 0.92, and 0.84, respectively), while mean differences from CENTRIFUGE HPLC were small but usually significant ([Na(+)]: 4.7 ± 7.9 mEql/L, -2.5 ± 9.3 mEq/L, 4.0 ± 10.9 mEq/L (all P CENTRIFUGE HPLC 95% of the time. The field (SYRINGE HORIBA) method of extracting and analyzing sweat from regional absorbent patches may be useful in obtaining sweat [Na(+)] when rapid estimates in a hot-humid field setting are needed.

  8. Validity and reliability of a field technique for sweat Na+ and K+ analysis during exercise in a hot‐humid environment

    Science.gov (United States)

    Baker, Lindsay B.; Ungaro, Corey T.; Barnes, Kelly A.; Nuccio, Ryan P.; Reimel, Adam J.; Stofan, John R.

    2014-01-01

    Abstract This study compared a field versus reference laboratory technique for extracting (syringe vs. centrifuge) and analyzing sweat [Na+] and [K+] (compact Horiba B‐722 and B‐731, HORIBA vs. ion chromatography, HPLC) collected with regional absorbent patches during exercise in a hot‐humid environment. Sweat samples were collected from seven anatomical sites on 30 athletes during 1‐h cycling in a heat chamber (33°C, 67% rh). Ten minutes into exercise, skin was cleaned/dried and two sweat patches were applied per anatomical site. After removal, one patch per site was centrifuged and sweat was analyzed with HORIBA in the heat chamber (CENTRIFUGE HORIBA) versus HPLC (CENTRIFUGE HPLC). Sweat from the second patch per site was extracted using a 5‐mL syringe and analyzed with HORIBA in the heat chamber (SYRINGE HORIBA) versus HPLC (SYRINGE HPLC). CENTRIFUGE HORIBA, SYRINGE HPLC, and SYRINGE HORIBA were highly related to CENTRIFUGE HPLC ([Na+]: ICC = 0.96, 0.94, and 0.93, respectively; [K+]: ICC = 0.87, 0.92, and 0.84, respectively), while mean differences from CENTRIFUGE HPLC were small but usually significant ([Na+]: 4.7 ± 7.9 mEql/L, −2.5 ± 9.3 mEq/L, 4.0 ± 10.9 mEq/L (all P CENTRIFUGE HPLC 95% of the time. The field (SYRINGE HORIBA) method of extracting and analyzing sweat from regional absorbent patches may be useful in obtaining sweat [Na+] when rapid estimates in a hot‐humid field setting are needed. PMID:24793982

  9. Report on intercomparison exercise SR-64. Determination of impurities in U3O8

    International Nuclear Information System (INIS)

    Doubek, N.; Bagliano, G.; Deron, S.

    1985-04-01

    The report presents results of a laboratory intercomparison of the determination of impurities in U 3 O 8 samples. 38 different elements were analyzed by the laboratories which participated in the SR-64 exercise. At the issue of the exercise it was possible to provide recommended values for 8 elements. The content of 11 other elements could be assigned as information values. Seven different techniques of analyses were used but 29% of the results were obtained by flame atomic absorption and 69% by emission spectrography

  10. Environmental Chemistry in the Undergraduate Laboratory.

    Science.gov (United States)

    Wenzel, Thomas J.; Austin, Rachel N.

    2001-01-01

    Discusses the importance of environmental chemistry and the use of laboratory exercises in analytical and general chemistry courses. Notes the importance of lab work in heightening student interest in coursework including problem-based learning in undergraduate curricula, ready adaptability of environmental coursework to existing curricula, and…

  11. Understanding System Utilization as a Limitation Associated with Cybersecurity Laboratories--A Literature Analysis

    Science.gov (United States)

    Pittman, Jason

    2013-01-01

    The use of laboratories as part of cybersecurity education is well evidenced in the existing literature. We are informed about the benefits, different types of laboratories and, in addition, underlying learning theories therein. Existing research also demonstrates that the success of employing cybersecurity laboratory exercises relies upon…

  12. Engineering Water Analysis Laboratory Activity.

    Science.gov (United States)

    Schlenker, Richard M.

    The purposes of water treatment in a marine steam power plant are to prevent damage to boilers, steam-operated equipment, and steam and condensate lives, and to keep all equipment operating at the highest level of efficiency. This laboratory exercise is designed to provide students with experiences in making accurate boiler water tests and to…

  13. Blended Learning within an Undergraduate Exercise Physiology Laboratory

    Science.gov (United States)

    Elmer, Steven J.; Carter, Kathryn R.; Armga, Austin J.; Carter, Jason R.

    2016-01-01

    In physiological education, blended course formats (integration of face-to-face and online instruction) can facilitate increased student learning, performance, and satisfaction in classroom settings. There is limited evidence on the effectiveness of using blending course formats in laboratory settings. We evaluated the impact of blended learning…

  14. Development and Initial Validation of the Volition in Exercise Questionnaire (VEQ)

    DEFF Research Database (Denmark)

    Elsborg, P.; Wikman, J. M.; Nielsen, G.

    2017-01-01

    The present study describes the development and validation of an instrument to measure volition in the exercise context. Volition describes an individual’s self-regulatory mental processes that are responsible for taking and maintaining a desirable action (e.g., exercising regularly). The scale...... structure was developed in an exploratory factor analysis which resulted in a reliable structure of the following six factors: Volitional Inhibition—Reasons, Volitional Inhibition—Postponing Training, Volitional Facilitation—Self-Confidence, Volitional Inhibition—Unrelated Thoughts, Volitional Inhibition...

  15. Brewing Beer in the Laboratory: Grain Amylases and Yeast's Sweet Tooth

    Science.gov (United States)

    Gillespie, Blake; Deutschman, William A.

    2010-01-01

    Brewing beer provides a straightforward and robust laboratory counterpart to classroom discussions of fermentation, a staple of the biochemistry curriculum. An exercise is described that provides several connections between lecture and laboratory content. Students first extract fermentable carbohydrates from whole grains, then ferment these with…

  16. A web-based virtual laboratory workbench for electrical circuits with ...

    African Journals Online (AJOL)

    A distinguishing feature of this Virtual Laboratory Workbench is that it allows the instructor flexibility in designing laboratory exercises so as to integrate specific knowledge objectives, outcome concepts and pre-requisites with the activity instructions. Another important benefit is that it has a watch-dog monitor that keeps a log ...

  17. Exercise interventions for smoking cessation.

    Science.gov (United States)

    Ussher, Michael H; Taylor, Adrian H; Faulkner, Guy E J

    2014-08-29

    -up and a benefit for exercise of borderline significance (p = 0.05) at the 12-month follow-up. Another study reported significantly higher abstinence rates at six month follow-up for a combined exercise and smoking cessation programme compared with brief smoking cessation advice. One study showed significantly higher abstinence rates for the exercise group versus a control group at the three-month follow-up but not at the end of treatment or 12-month follow-up. The other studies showed no significant effect for exercise on abstinence. Only two of the 20 trials offered evidence for exercise aiding smoking cessation in the long term. All the other trials were too small to reliably exclude an effect of intervention, or included an exercise intervention which may not have been sufficiently intense to achieve the desired level of exercise. Trials are needed with larger sample sizes, sufficiently intense interventions in terms of both exercise intensity and intensity of support being provided, equal contact control conditions, and measures of exercise adherence and change in physical activity in both exercise and comparison groups.

  18. Final report on fourth interlaboratory comparison exercise for δ2H and δ18O analysis of water samples (WICO2011)

    International Nuclear Information System (INIS)

    Ahmad, M.; Aggarwal, P.; Duren, M. van; Poltenstein, L.; Araguas, L.; Kurttas, T.; Wassenaar, L.I.

    2012-01-01

    The IAEA Isotope Hydrology Laboratory organized the fourth interlaboratory comparison exercise for laboratories engaged in routine analysis of hydrogen and oxygen stable isotope composition of water samples in 2011. Three similar exercises were carried out in 1995, in 1999 and in 2002. However, the tradition of IAEA water stable isotope inter-laboratory comparison is much older. Two interlaboratory comparison trials for isotope hydrology laboratories were carried out in the sixties and seventies, which revealed problems with use of the NBS-1 international standard; these data were used to calibrate the newly produced primary reference materials VSMOW and SLAP. The WICO2011 exercise was announced in February 2011 on the internet, via the ISOGEOCHEM news group of Isogeochemistry and by email to all participants of the former intercomparisons. Altogether 174 laboratories expressed interest to participate in the exercise. Four water samples prepared and calibrated at the IAEA Isotope Hydrology Laboratory were labelled IAEA-OH-13 to IAEA-OH-16, which are referred to in this report as OH-13 to OH-16. By the end of the reporting deadline (the end of August 2011) altogether 137 laboratories from 53 countries had submitted 172 datasets back to the IAEA on the oxygen and hydrogen isotopic composition of these water samples. The four water samples cover the range of δ18O and δ2H values typical for the majority of natural waters. The samples were bottled from 30 L stainless steel storage barrels into 30 mL securely-capped brown glass bottles, serially numbered at the time of filling. Each laboratory received a set of four samples with a corresponding code. This code (assigned randomly) forms the Identification (ID) code used throughout the exercise and in the tables and graphs of this report for each laboratory. The ID code is not related to the order of the list of participating laboratories. The identity of participating laboratories will not be revealed unless each

  19. Activity-based costing methodology as tool for costing in hematopathology laboratory

    Directory of Open Access Journals (Sweden)

    Gujral Sumeet

    2010-01-01

    Full Text Available Background: Cost analysis in laboratories represents a necessary phase in their scientific progression. Aim: To calculate indirect cost and thus total cost per sample of various tests at Hematopathology laboratory (HPL Settings and Design: Activity-based costing (ABC method is used to calculate per cost test of the hematopathology laboratory. Material and Methods: Information is collected from registers, purchase orders, annual maintenance contracts (AMCs, payrolls, account books, hospital bills and registers along with informal interviews with hospital staff. Results: Cost per test decreases as total number of samples increases. Maximum annual expense at the HPL is on reagents and consumables followed by manpower. Cost per test is higher for specialized tests which interpret morphological or flow data and are done by a pathologist. Conclusions: Despite several limitations and assumptions, this was an attempt to understand how the resources are consumed in a large size government-run laboratory. The rate structure needs to be revised for most of the tests, mainly for complete blood counts (CBC, bone marrow examination, coagulation tests and Immunophenotyping. This costing exercise is laboratory specific and each laboratory needs to do its own costing. Such an exercise may help a laboratory redesign its costing structure or at least understand the economics involved in the laboratory management.

  20. A Laboratory Notebook System

    OpenAIRE

    Schreiber, Andreas

    2012-01-01

    Many scientists are using a laboratory notebook when conducting experiments. The scientist documents each step, either taken in the experiment or afterwards when processing data. Due to computerized research systems, acquired data increases in volume and becomes more elaborate. This increases the need to migrate from originally paper-based to electronic notebooks with data storage, computational features and reliable electronic documentation. This talks describes a laboratory notebook bas...

  1. Students' Framing of Laboratory Exercises Using Infrared Cameras

    Science.gov (United States)

    Haglund, Jesper; Jeppsson, Fredrik; Hedberg, David; Schönborn, Konrad J.

    2015-01-01

    Thermal science is challenging for students due to its largely imperceptible nature. Handheld infrared cameras offer a pedagogical opportunity for students to see otherwise invisible thermal phenomena. In the present study, a class of upper secondary technology students (N = 30) partook in four IR-camera laboratory activities, designed around the…

  2. An innovative exercise method to simulate orbital EVA work - Applications to PLSS automatic controls

    Science.gov (United States)

    Lantz, Renee; Vykukal, H.; Webbon, Bruce

    1987-01-01

    An exercise method has been proposed which may satisfy the current need for a laboratory simulation representative of muscular, cardiovascular, respiratory, and thermoregulatory responses to work during orbital extravehicular activity (EVA). The simulation incorporates arm crank ergometry with a unique body support mechanism that allows all body position stabilization forces to be reacted at the feet. By instituting this exercise method in laboratory experimentation, an advanced portable life support system (PLSS) thermoregulatory control system can be designed to more accurately reflect the specific work requirements of orbital EVA.

  3. Machinery safety of lathe machine using SHARP-systemic human action reliability procedure: a pilot case study in academic laboratory

    Science.gov (United States)

    Suryoputro, M. R.; Sari, A. D.; Sugarindra, M.; Arifin, R.

    2017-12-01

    This research aimed to understand the human reliability analysis, to find the SHARP method with its functionality on case study and also emphasize the practice in Lathe machine, continued with identifying improvement that could be made to the existing safety system. SHARP comprises of 7 stages including definition, screening, breakdown, representation, impact assessment, quantification and documentation. These steps were combined and analysed using HIRA, FTA and FMEA. HIRA analysed the lathe at academic laboratory showed the level of the highest risk with a score of 9 for the activities of power transmission parts and a score of 6 for activities which shall mean the moving parts required to take action to reduce the level of risk. Hence, the highest RPN values obtained in the power transmission activities with a value of 18 in the power transmission and then the activities of moving parts is 12 and the activities of the operating point of 8. Thus, this activity has the highest risk of workplace accidents in the operation. On the academic laboratory the improvement made on the engineering control initially with a machine guarding and completed with necessary administrative controls (SOP, work permit, training and routine cleaning) and dedicated PPEs.

  4. Does exercise stimulate protein breakdown in humans? Isotopic approaches to the problem

    International Nuclear Information System (INIS)

    Wolfe, R.R.

    1987-01-01

    Protein metabolism in exercise has been investigated for 100 yr, yet it is still unclear if exercise induces an increased rate of protein breakdown. We have recently addressed this general question in a series of experiments in human subjects using stable isotopic tracers. In this paper, the results of those studies are reviewed. We have found that in light exercise the de-carboxylation of leucine is increased. However, urea production is not increased correspondingly, nor is the rate of incorporation into urea of nitrogen from either leucine or lysine. Further complicating the picture is the fact that lysine de-carboxylation is not markedly elevated in exercise. From these studies, we must conclude that isotopic techniques which have achieved general acceptance in other circumstances cannot reliably be used to answer the question of whether exercise stimulates protein breakdown in humans. However, these methods do provide results which enable a better understanding of the metabolism of the individual amino acids in exercise

  5. Results of the regional intercomparison exercise for the determination of operational quantity Hp(d) in Latin America

    International Nuclear Information System (INIS)

    Saravi, M.; Zaretzky, A.; Lindner, C.; Diaz, J.; Walwyn, G.; Souza, D.; Amorin, R.; Gregory, B.; Papadopulos, S.; Meghzifene, A.; Ferruz Cruz, P.; Cruz Suarez, R.

    2005-01-01

    Full text: Several intercomparison exercises were organized by the International Atomic Energy Agency (IAEA) on the determination of operational quantities at the regional or interregional basis. These exercises revealed significant differences in the approach, methods and assumptions, and consequently in the measurement results obtained by participating laboratories. In the Latin America region, an intercomparison for determination of operational quantity Hp(10), organized within the frame of a technical cooperation regional project, was completed mid-2004, as a follow-up to previous exercises carried out during the 1990s. Eighteen laboratories from 19 member states participated in the first phase; the second phase grouped 15 laboratories from 16 member states. Dosimeter irradiations (5 different radiation qualities for photon simulating workplace fields) were done by 4 Secondary Standards Dosimetry Laboratories (SSDL). The preparations for the exercise involved an audit by the IAEA SSDL, where reference irradiations were provided to all participants for verification of their system. During the first phase (2002/03), only 9 out of 18 laboratories met the performance requirements for such monitoring services. Necessary corrective actions and procedure verification were implemented, and staff involved in these evaluations were subsequently trained. During the second phase (2004), 11 out of 15 laboratories fulfilled the performance criteria. The 4 laboratories still having difficulties in assessing occupational exposure participated in a results meeting, during which problem areas were identified. An ongoing technical cooperation mission is expected to assist these laboratories accordingly. There has been a definite improvement in the second phase and most laboratories demonstrated a good performance in the quantity tested. The technical results clearly show that the laboratories' capability in assessing occupational exposure from external sources of radiation is

  6. Adapted PBL Practical Exercises: Benefits for Apprentices

    Science.gov (United States)

    Monks, Alan

    2010-01-01

    Use was made of adapted problem-based learning (PBL) practical exercises to address the disengagement of apprentices with the existing assembly-style electronic laboratory programme. Apprentices perceived the traditional routines as having little real-world relevance. This detracted from the value and benefit to them of the practical component of…

  7. An initial limited biodosimetry inter-comparison exercise: FOI and DRDC Ottawa

    International Nuclear Information System (INIS)

    Stricklin, D.; Wilkinson, D.; Arvidsson, E.; Prud'homme-Lalonde, L.; Thorleifson, E.; Mullins, D.; Lachapelle, S.

    2007-01-01

    While biodosimetry is a valuable tool in radiation dose assessment, the dicentric assay, which is the most validated method to date, requires some degree of technical competence. Recently published ISO guidelines indicate the need for documenting competence and establishment of quality control programs. Inter-laboratory comparisons are required to document the ability to perform reproducible and accurate assessments. FOI and DRDC Ottawa have conducted an initial limited biodosimetry exercise inter-comparison for quality assurance purposes. The exercise involved blinded exchange of three previously prepared slides from each laboratory from samples that had been evaluated for each lab's dose-response curve. Approximately 100 cells from each slide were evaluated and aberration frequencies reported and compared to the expected frequencies. The limited number of cells evaluated for each sample could not permit statistically distinguishing a 20% difference in all the samples. However, the results indicated reasonable agreement in analyses for all samples for triage purposes. Comparison of aberration frequencies, rather than dose estimates, further illustrates consistent scoring criteria between the two laboratories. The exercise conducted by FOI and DRDC Ottawa provided an efficient means of documenting expertise. Such cooperation further establishes the international biodosimetry network and ensures our readiness for emergency response

  8. Exercise after breast cancer treatment: current perspectives

    Directory of Open Access Journals (Sweden)

    Dieli-Conwright CM

    2015-10-01

    Full Text Available Christina M Dieli-Conwright, Breanna Z Orozco Division of Biokinesiology and Physical Therapy, Women's Health and Exercise Laboratory, University of Southern California, Los Angeles, CA, USA Abstract: Over the past 2 decades, great strides have been made in the field of exercise-oncology research, particularly with breast cancer. This area of research is particularly important since there are >2.8 million breast cancer survivors who are in need of an intervention that can offset treatment-related side effects. Noticeable reductions in physical fitness (ie, cardiopulmonary fitness and muscular strength, negative changes in body composition (ie, increase in body mass, decrease in lean body mass, and increase in fat mass, increased fatigue, depression, or anxiety are some of the common side effects of cancer treatments that negatively impact overall quality of life and increase the risk for the development of comorbidities. Exercise plays a vital role in improving cardiopulmonary function, psychological events, muscular strength, and endurance in breast cancer survivors, and thus should be considered as a key factor of lifestyle intervention to reverse negative treatment-related side effects. The purpose of this review is to address current perspectives on the benefits of aerobic and resistance exercise after breast cancer treatments. This review is focused on the well-established benefits of exercise on physical and emotional well-being, bone health, lymphedema management, and the postulated benefits of exercise on risk reduction for recurrence of breast cancer. Keywords: breast cancer, exercise, physical well-being

  9. Application of Reliability in Breakwater Design

    DEFF Research Database (Denmark)

    Christiani, Erik

    methods to design certain types of breakwaters. Reliability analyses of the main armour and toe berm interaction is exemplified to show the effect of a multiple set of failure mechanisms. First the limit state equations of the main armour and toe interaction are derived from laboratory tests performed...... response, but in one area information has been lacking; bearing capacity has not been treated in depth in a probabilistic manner for breakwaters. Reliability analysis of conventional rubble mound breakwaters and conventional vertical breakwaters is exemplified for the purpose of establishing new ways...... by Bologna University. Thereafter a multiple system of failure for the interaction is established. Relevant stochastic parameters are characterized prior to the reliability evaluation. Application of reliability in crown wall design is illustrated by deriving relevant single foundation failure modes...

  10. Robust and reliable fuel cells; Robusta och tillfoerlitliga braensleceller

    Energy Technology Data Exchange (ETDEWEB)

    Nordlund, Joakim [Cellkraft AB, Stockholm (Sweden)

    2012-03-15

    For fuel cells to be a viable alternative for backup power in applications, where reliability is a critical factor, the reliability of fuel cells has to be high and documented. Based on intrinsic properties of fuel cells, it is safe to argue that it is possible to make them highly reliable, but to unleash the full reliability potential of fuel cells, some great engineering work has to be performed. Cellkraft has since many years been addressing this issue and this project is an important piece of this puzzle. The project included both a large number of laboratory testing of fuel cells and long experiments in field environment to verify the results from the laboratory work. The development work performed within this project is a solid base for the continuous work to fulfil Cellkraft's own, tough, technical reliability targets. The project targets below were achieved within this project: 1. The fuel cell start with 100 % reliability. 2. The fuel cell provides nominal power within 30 seconds in 100 % of the cases. 3. The fuel cell keeps providing nominal power as long as there is a demand in 100 % of the cases. 4. No cell in the fuel cell deviates from the mean cell potential with more than 0,1 V at full power.

  11. Effectiveness of inquiry-based learning in an undergraduate exercise physiology course.

    Science.gov (United States)

    Nybo, Lars; May, Michael

    2015-06-01

    The present study was conducted to investigate the effects of changing a laboratory physiology course for undergraduate students from a traditional step-by-step guided structure to an inquiry-based approach. With this aim in mind, quantitative and qualitative evaluations of learning outcomes (individual subject-specific tests and group interviews) were performed for a laboratory course in cardiorespiratory exercise physiology that was conducted in one year with a traditional step-by-step guided manual (traditional course) and the next year completed with an inquiry-based structure (I-based course). The I-based course was a guided inquiry course where students had to design the experimental protocol and conduct their own study on the basis of certain predefined criteria (i.e., they should evaluate respiratory responses to submaximal and maximal exercise and provide indirect and direct measures of aerobic exercise capacity). The results indicated that the overall time spent on the experimental course as well as self-evaluated learning outcomes were similar across groups. However, students in the I-based course used more time in preparation (102 ± 5 min) than students in the traditional course (42 ± 3 min, P traditional course. Furthermore, students in the I-based course achieved a higher (P traditional course (31 ± 4%). Although students were unfamiliar with cardiorespiratory exercise physiology and the experimental methods before the course, it appears that an inquiry-based approach rather than one that provides students with step-by-step instructions may benefit learning outcomes in a laboratory physiology course. Copyright © 2015 The American Physiological Society.

  12. Scenario guidance handbook for emergency-preparedness exercises at nuclear facilities

    International Nuclear Information System (INIS)

    Laughlin, G.J.; Martin, G.F.; Desrosiers, A.E.

    1983-01-01

    As part of the Emergency Preparedness Implementation Appraisal Program conducted by the Nuclear Regulatory Commission (NRC) with the technical assistance of the Pacific Northwest Laboratory (PNL), emergency preparedness exercises are observed on an annual basis at all licensed reactor facilities. One of the significant findings to arise from these observations was that a large number of the commonly observed problems originated in the design of the scenarios used as a basis for each exercise. In an effort to help eliminate some of these problems a scenario guidance handbook has been generated by PNL for the NRC to assist nuclear power plant licensees in developing scenarios for emergency preparedness exercises

  13. RELIABILITY OF ANKLE-FOOT MORPHOLOGY, MOBILITY, STRENGTH, AND MOTOR PERFORMANCE MEASURES.

    Science.gov (United States)

    Fraser, John J; Koldenhoven, Rachel M; Saliba, Susan A; Hertel, Jay

    2017-12-01

    Assessment of foot posture, morphology, intersegmental mobility, strength and motor control of the ankle-foot complex are commonly used clinically, but measurement properties of many assessments are unclear. To determine test-retest and inter-rater reliability, standard error of measurement, and minimal detectable change of morphology, joint excursion and play, strength, and motor control of the ankle-foot complex. Reliability study. 24 healthy, recreationally-active young adults without history of ankle-foot injury were assessed by two clinicians on two occasions, three to ten days apart. Measurement properties were assessed for foot morphology (foot posture index, total and truncated length, width, arch height), joint excursion (weight-bearing dorsiflexion, rearfoot and hallux goniometry, forefoot inclinometry, 1 st metatarsal displacement) and joint play, strength (handheld dynamometry), and motor control rating during intrinsic foot muscle (IFM) exercises. Clinician order was randomized using a Latin Square. The clinicians performed independent examinations and did not confer on the findings for the duration of the study. Test-retest and inter-tester reliability and agreement was assessed using intraclass correlation coefficients (ICC 2,k ) and weighted kappa ( K w ). Test-retest reliability ICC were as follows: morphology: .80-1.00, joint excursion: .58-.97, joint play: -.67-.84, strength: .67-.92, IFM motor rating: K W -.01-.71. Inter-rater reliability ICC were as follows: morphology: .81-1.00, joint excursion: .32-.97, joint play: -1.06-1.00, strength: .53-.90, and IFM motor rating: K w .02-.56. Measures of ankle-foot posture, morphology, joint excursion, and strength demonstrated fair to excellent test-retest and inter-rater reliability. Test-retest reliability for rating of perceived difficulty and motor performance was good to excellent for short-foot, toe-spread-out, and hallux exercises and poor to fair for lesser toe extension. Joint play measures had

  14. Effect of Submaximal Warm-up Exercise on Exercise-induced Asthma in African School Children.

    Science.gov (United States)

    Mtshali, B F; Mokwena, K; Oguntibeju, O O

    2015-03-01

    Regular physical activity has long been regarded as an important component of a healthy lifestyle. Exercise-induced asthma (EIA) is one of the major problems interfering with the performance of exercise. A warm-up exercise programme has been cited as a non-pharmacologic means of reducing EIA, but its effect has not been fully elucidated. The aims of this study were to determine the prevalence of unrecognized EIA in Pretoria primary school children, determine the effect of a warm-up exercise programme on EIA and to establish the relationship between history of allergy, family history of asthma and EIA. A random sample of 640 school children was selected. The study was divided into three phases. In phase one, a descriptive cross-sectional study was done using the standardized European Community Respiratory Health Survey (ECRHS) questionnaire. In phase two, non-asthmatic participants that returned a completed questionnaire were included in the field study. Pre-test and post-test experimental designs were used, where peak expiratory flow rate (PEFR) was measured at baseline and within ten minutes after exercise. A total of 340 subjects completed the Free Running Asthma Screening Test (FRAST); EIA was defined as a decrease in baseline PEFR ≥ 10% after exercise and 75 children (22%) had EIA. In phase three, 29 of the 75 subjects participated in the warm-up programme which was performed in the laboratory and subjects acted as their own controls. Predefined protocols for the study were followed. Seventy-five (22%) of the 340 participants had EIA. The mean age, height and weight were 10.51 years, 139.26 cm and 33.45 kg, respectively. Exercise-induced asthma symptoms were cough (25%), chest pain (16%), wheeze (12%) and chest tightness (12%). The history of allergy was 75%, family history of allergy 40% and positive history of allergy when near animals, feathers or in dusty areas 38%. Wheezing during or after exercise, wheezing when near animals, feathers or in dusty areas

  15. An Easily Assembled Laboratory Exercise in Computed Tomography

    Science.gov (United States)

    Mylott, Elliot; Klepetka, Ryan; Dunlap, Justin C.; Widenhorn, Ralf

    2011-01-01

    In this paper, we present a laboratory activity in computed tomography (CT) primarily composed of a photogate and a rotary motion sensor that can be assembled quickly and partially automates data collection and analysis. We use an enclosure made with a light filter that is largely opaque in the visible spectrum but mostly transparent to the near…

  16. Car-borne gamma spectrometry: a virtual exercise in emergency response

    DEFF Research Database (Denmark)

    Dowdall, M.; Smethurst, M.A.; Watson, R.

    2012-01-01

    experience in the field however are limited by cost considerations and practicability. These limitations are exacerbated by the fact that field data can differ significantly from data generated in the laboratory. As a means of exercising existing emergency measuring/surveying capability and introducing car......-borne measurements to a larger group, a virtual exercise was devised. The exercise ORPEX (Orphan Sources and Fresh Fallout Virtual Exercise in Mobile Measurement) featured two typical emergency scenarios: a search for orphan sources and surveying to delineate fallout from a local release point. Synthetic spectral...... a local fire involving radioactive material were added to real car-borne data, participants being asked to produce maps identifying and characterising the regions of contamination. Fourteen individual organisations from seven different countries supplied results which indicated that for strong sources...

  17. Bioethics in the Laboratory: Synthesis and Interactivity.

    Science.gov (United States)

    Murray, Kevin J.

    1999-01-01

    Describes the implementation of a bioethics laboratory exercise that incorporates a variety of instructional strategies. In the activity, General Biology students consider relevant and interesting topics of bioethical importance and prepare classroom presentations on the different viewpoints normally attendant to ethical topics. Includes an…

  18. Hot spot exercise: 1975 (HSX-75)

    International Nuclear Information System (INIS)

    Trolan, R.T.; Wilson, R.L.; Jessen, F.W.

    1976-01-01

    A special unannounced exercise, called HOT SPOT Exercise--1975 (HSX-75), was prepared to test the general capability of the LLL ALERT Program to activate and deploy the LLL and Sandia Laboratory, Livermore (SLL) component of the ERDA/ARG. The exercise activities were limited to the LLL facilities in Livermore and the Site 300 explosive test facility located approximately 15 miles southeast of Livermore. The exercise simulated an accident at a U.S. Army storage facility (Site 300). The simulated accident involved two LLL designed weapons (W-70). One weapon was dropped during unloading operations and ignited the gas tank of the weapon transporter. The subsequent fire caused a low-order detonation of the high explosive component. The fire caused dispersal of fissile material downwind from the site. A second weapon was damaged in the explosion by fragments from the first weapon. The extent of damage to the second weapon was initially unknown. The exercise was conducted on September 23, 1975. A complete description of the specific nature of the simulated accident is contained in the scenario. Umpires were assigned to evaluate and subsequently report on the effectiveness of the response. All test objectives were accomplished. The following appendices are included: operational safety procedures, photographs and site map, HOT SPOT equipment, atmospheric release advisory capability, personnel list, chronology of events, and critique comments

  19. Radionuclide observables during the Integrated Field Exercise of the Comprehensive Nuclear-Test-Ban Treaty

    International Nuclear Information System (INIS)

    Burnett, Jonathan L.; Miley, Harry S.; Milbrath, Brian D.

    2016-01-01

    In 2014 the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) undertook an Integrated Field Exercise (IFE14) in Jordan. The exercise consisted of a simulated 0.5–2 kT underground nuclear explosion triggering an On-site Inspection (OSI) to search for evidence of a Treaty violation. This research paper evaluates two of the OSI techniques used during the IFE14, laboratory-based gamma-spectrometry of soil samples and in-situ gamma-spectrometry, both of which were implemented to search for 17 OSI relevant particulate radionuclides indicative of nuclear explosions. The detection sensitivity is evaluated using real IFE and model data. It indicates that higher sensitivity laboratory measurements are the optimum technique during the IFE and within the Treaty/Protocol-specified OSI timeframes. - Highlights: • The 2014 Integrated Field Exercise occurred in Jordan. • The detection sensitivity for two On-site Inspection techniques was evaluated. • The techniques search for 17 particulate radionuclides indicative of nuclear explosions. • Laboratory-based gamma-spectrometry of soil samples was the optimum technique.

  20. Validity and Reliability of a Glucometer Against Industry Reference Standards.

    Science.gov (United States)

    Salacinski, Amanda J; Alford, Micah; Drevets, Kathryn; Hart, Sarah; Hunt, Brian E

    2014-01-01

    As an appealing alternative to reference glucose analyzers, portable glucometers are recommended for self-monitoring at home, in the field, and in research settings. The purpose was to characterize the accuracy and precision, and bias of glucometers in biomedical research. Fifteen young (20-36 years; mean = 24.5), moderately to highly active men (n = 10) and women (n = 5), defined by exercising 2 to 3 times a week for the past 6 months, were given an oral glucose tolerance test (OGTT) after an overnight fast. Participants ingested 50, 75, or 150 grams of glucose over a 5-minute period. The glucometer was compared to a reference instrument. The glucometer had 39% of values within 15% of measurements made using the reference instrument ranging from 45.05 to 169.37 mg/dl. There was both a proportional (-0.45 to -0.39) and small fixed (5.06 and 0.90 mg/dl) bias. Results of the present study suggest that the glucometer provided poor validity and reliability results compared to the results provided by the reference laboratory analyzer. The portable glucometers should be used for patient management, but not for diagnosis, treatment, or research purposes. © 2014 Diabetes Technology Society.

  1. The effect of regular corrective exercise on musculoskeletal deformities in Khorramabad school girls

    Directory of Open Access Journals (Sweden)

    bahman hasanvand

    2011-06-01

    Conclusion: The findings of this study emphasize the reliable, accurate, feasible, and easy methods for decreasing abnormalities. Furthermore, it showed that the corrective exercise programs, can reduce the abnormalities in oldness.

  2. Wind Turbine Drivetrain Reliability Collaborative Workshop: A Recap

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sheng, Shuangwen [National Renewable Energy Lab. (NREL), Golden, CO (United States); Cotrell, Jason [National Renewable Energy Lab. (NREL), Golden, CO (United States); Greco, Aaron [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-08-01

    The Wind Turbine Drivetrain Reliability Collaborative Workshop was convened by the National Renewable Energy Laboratory (NREL), Argonne National Laboratory, and the U.S. Department of Energy to explore the state of the art in wind turbine drivetrain mechanical system reliability as well as research and development (R&D) challenges that if solved could have significant benefits. The workshop was held at the Research Support Facility on NREL's main campus in Golden, Colorado, from February 16-17, 2016. More than 120 attendees participated from industry, academia, and government. Plenary presentations covered wind turbine drivetrain design, testing, and analysis; tribology -- the science and engineering of interacting surfaces in relative motion -- and failure modes; and condition monitoring and data analytics. In addition to the presentations, workshops were held in each of these areas to discuss R&D challenges. This report serves as a summary of the presentations, workshops, and conclusions on R&D challenges in wind turbine drivetrain reliability.

  3. Representative Sampling for reliable data analysis

    DEFF Research Database (Denmark)

    Petersen, Lars; Esbensen, Kim Harry

    2005-01-01

    regime in order to secure the necessary reliability of: samples (which must be representative, from the primary sampling onwards), analysis (which will not mean anything outside the miniscule analytical volume without representativity ruling all mass reductions involved, also in the laboratory) and data...

  4. Open soundcard as a platform for practical, laboratory study of digital audio

    DEFF Research Database (Denmark)

    Dimitrov, Smilen; Serafin, Stefania

    2014-01-01

    This article investigates how lacking suitable platforms for laboratory exercises becomes a learning problem, limiting the practical experience students gain. In engineering education, laboratory demonstration difficulty of issues like real-time streaming in digital signal and audio processing...... afforded by such laboratories, and their open nature, could testably improve the diversity of demonstrated practical topics, while maintaining engineering students' motivation....

  5. Curative and health enhancement effects of aquatic exercise: evidence based on interventional studies

    Directory of Open Access Journals (Sweden)

    Honda T

    2012-03-01

    Full Text Available Takuya Honda1, Hiroharu Kamioka21Research Fellow of the Japanese Society for the Promotion of Science, 2Laboratory of Physical and Health Education, Faculty of Regional Environment Science, Tokyo University of Agriculture, Tokyo, JapanBackground: The purpose of this study was to report on the health benefits and curative effects of aquatic exercise.Methods: We adopted the results of high-grade study designs (ie, randomized controlled trials and nonrandomized controlled trials, for which there were many studies on aquatic exercise. Aquatic exercise, in this study, means walking in all directions, stretching, and various exercises and conditioning performed with the feet grounded on the floor of a swimming pool. We excluded swimming. We decided to treat aquatic exercise, underwater exercise, hydrotherapy, and pool exercise as all having the same meaning.Results: Aquatic exercise had significant effects on pain relief and related outcome measurements for locomotor diseases.Conclusion: Patients may become more active, and improve their quality of life, as a result of aquatic exercise.Keywords: aquatic exercise, health enhancement, evidence

  6. The development of remote teaching laboratory access software for multi-slice computed optical tomography for use in undergraduate nuclear education

    International Nuclear Information System (INIS)

    Price, T.J.; Nichita, E.

    2013-01-01

    Internet-based laboratory exercises were developed for a course on biomedical imaging at the University of Ontario Institute of Technology. These exercises used a multi-slice computed optical tomography machine named DeskCAT to instruct students on the principals of computed tomography. User management software was developed which enabled course instructors to quickly set up a computer to accept a series of scheduled remote user connections for a classroom. Laboratory exercises using the DeskCAT machine were developed to be conducted remotely. (author)

  7. The development of remote teaching laboratory access software for multi-slice computed optical tomography for use in undergraduate nuclear education

    Energy Technology Data Exchange (ETDEWEB)

    Price, T.J.; Nichita, E., E-mail: Terry.Price@gmail.com [Univ. of Ontario Inst. of Technology, Oshawa, Ontario (Canada)

    2013-07-01

    Internet-based laboratory exercises were developed for a course on biomedical imaging at the University of Ontario Institute of Technology. These exercises used a multi-slice computed optical tomography machine named DeskCAT to instruct students on the principals of computed tomography. User management software was developed which enabled course instructors to quickly set up a computer to accept a series of scheduled remote user connections for a classroom. Laboratory exercises using the DeskCAT machine were developed to be conducted remotely. (author)

  8. Sympatho-adrenergic activation by endurance exercise: Effect on metanephrines spillover and its role in predicting athlete's performance.

    Science.gov (United States)

    Danese, Elisa; Tarperi, Cantor; Salvagno, Gian Luca; Guzzo, Alessandra; Sanchis-Gomar, Fabian; Festa, Luca; Bertinato, Luciano; Montagnana, Martina; Schena, Federico; Lippi, Giuseppe

    2018-03-20

    The sympatho-adrenergic activation during exercise is implicated in many cardiovascular respiratory and metabolic adaptations which have been thought to partially explain the different levels of performance observed between trained and untrained subjects. To date, no evidence exists about the association between competition performance and markers of "acute stress response". We designed this study to investigate; (i) the acute sympatho-adrenergic activation during endurance exercise in recreational runners by measuring plasma levels of free metanephrine (MN) and normethanephrine (NMN) before and after a half-marathon run; (ii) the association between the metanephrines levels and the running time. 26 amateur runners (15 males, 11 females) aged 30 to 63 years were enrolled. The quantification of MN and NMN was performed by LC-MS/MS. Anthropometric ergonomic and routine laboratory data were recorded. Statistical analyses included paired T -test, univariate and multivariate regressions. The post-run values of MN and NMN displayed a nearly 3.5 and 7 fold increase respectively compared to the baseline values ( p performance. No correlations were found for MN values. NMN is a reliable marker of sympatho-adrenergic activation by exercise and can predict endurance performance in the individual athlete. Adaptation phenomenon occurring not only in the adrenal medulla might represent the biological mechanism underlying this association. Further studies on sympatho-adrenergic activation, competition performance and training status should contemplate the measurement of these metabolites instead of their unstable precursors.

  9. Overall approaches and experiences of first-time participants in the Nuclear Forensics International Technical Working Group's Fourth Collaborative Material Exercise (CMX-4)

    International Nuclear Information System (INIS)

    Ho, D.M.L.; Nelwamondo, A.N.; Hancke, J.J.; Ramebaeck, Henrik

    2018-01-01

    The Fourth Collaborative Material Exercise (CMX-4) of the Nuclear Forensics International Technical Working Group (ITWG) registered the largest participation for this exercise in nuclear forensics, with seven of the 17 laboratories participating for the first time. Each of the laboratories had their strategic role to play in its respective country, analyzing real-world samples using their in-house resources. The scenario was fictitious but was thoughtfully crafted to engage participants in nuclear forensic investigations. In this paper, participants from five of the first-time laboratories shared their individual experience in this exercise, from preparation to analysis of samples. (author)

  10. Validation of the Basic Psychological Needs in Exercise Scale in a Portuguese sample.

    Science.gov (United States)

    Moutão, João Miguel Raimundo Peres; Serra, Luis Filipe Cid; Alves, José Augusto Marinho; Leitão, José Carlos; Vlachopoulos, Symeon P

    2012-03-01

    In line with self-determination theory (SDT: Deci & Ryan, 1985, 2002) the satisfaction of the basic psychological needs for autonomy, competence, and relatedness has been identified as an important predictor of behavior and optimal functioning in various contexts including exercise. The lack of a valid and reliable instrument to assess the extent to which these needs are fulfilled among Portuguese exercise participants limits the evaluation of causal links proposed by SDT in the Portuguese exercise context. The aim of the present study was to translate into Portuguese and validate the Basic Psychological Needs in Exercise Scale (BPNES: Vlachopoulos & Michailidou, 2006). Using data from 522 exercise participants the findings provided evidence of strong internal consistency of the translated BPNES subscales while confirmatory factor analysis supported a good fit of the correlated 3-factor model to the data. The present findings support the use of the translated into Portuguese BPNES to assess the extent of basic psychological need fulfilment among Portuguese exercise participants.

  11. Artificial Urine for Teaching Urinalysis Concepts and Diagnosis of Urinary Tract Infection in the Medical Microbiology Laboratory.

    Science.gov (United States)

    Khan, Latifa B; Read, Hannah M; Ritchie, Stephen R; Proft, Thomas

    2017-01-01

    Dipstick urinalysis is an informative, quick, cost-effective and non-invasive diagnostic tool that is useful in clinical practice for the diagnosis of urinary tract infections (UTIs), kidney diseases, and diabetes. We used dipstick urinalysis as a hands-on microbiology laboratory exercise to reinforce student learning about UTIs with a particular focus on cystitis, which is a common bacterial infection. To avoid exposure to potentially contaminated human urine samples, we prepared artificial urine using easily acquired and affordable ingredients, which allowed less-experienced students to perform urinalysis without the risk of exposure to pathogenic organisms and ensured reliable availability of the urine samples. This practical class taught medical students how to use urinalysis data in conjunction with medical history to diagnose diseases from urine samples and to determine a treatment plan for clinical scenarios.

  12. Laboratory Works Designed for Developing Student Motivation in Computer Architecture

    Directory of Open Access Journals (Sweden)

    Petre Ogrutan

    2017-02-01

    Full Text Available In light of the current difficulties related to maintaining the students’ interest and to stimulate their motivation for learning, the authors have developed a range of new laboratory exercises intended for first-year students in Computer Science as well as for engineering students after completion of at least one course in computers. The educational goal of the herein proposed laboratory exercises is to enhance the students’ motivation and creative thinking by organizing a relaxed yet competitive learning environment. The authors have developed a device including LEDs and switches, which is connected to a computer. By using assembly language, commands can be issued to flash several LEDs and read the states of the switches. The effectiveness of this idea was confirmed by a statistical study.

  13. Accuracy and reliability of peer assessment of athletic training psychomotor laboratory skills.

    Science.gov (United States)

    Marty, Melissa C; Henning, Jolene M; Willse, John T

    2010-01-01

    Peer assessment is defined as students judging the level or quality of a fellow student's understanding. No researchers have yet demonstrated the accuracy or reliability of peer assessment in athletic training education. To determine the accuracy and reliability of peer assessment of athletic training students' psychomotor skills. Cross-sectional study. Entry-level master's athletic training education program. First-year (n  =  5) and second-year (n  =  8) students. Participants evaluated 10 videos of a peer performing 3 psychomotor skills (middle deltoid manual muscle test, Faber test, and Slocum drawer test) on 2 separate occasions using a valid assessment tool. Accuracy of each peer-assessment score was examined through percentage correct scores. We used a generalizability study to determine how reliable athletic training students were in assessing a peer performing the aforementioned skills. Decision studies using generalizability theory demonstrated how the peer-assessment scores were affected by the number of participants and number of occasions. Participants had a high percentage of correct scores: 96.84% for the middle deltoid manual muscle test, 94.83% for the Faber test, and 97.13% for the Slocum drawer test. They were not able to reliably assess a peer performing any of the psychomotor skills on only 1 occasion. However, the φ increased (exceeding the 0.70 minimal standard) when 2 participants assessed the skill on 3 occasions (φ  =  0.79) for the Faber test, with 1 participant on 2 occasions (φ  =  0.76) for the Slocum drawer test, and with 3 participants on 2 occasions for the middle deltoid manual muscle test (φ  =  0.72). Although students did not detect all errors, they assessed their peers with an average of 96% accuracy. Having only 1 student assess a peer performing certain psychomotor skills was less reliable than having more than 1 student assess those skills on more than 1 occasion. Peer assessment of psychomotor skills

  14. "Graded Cycling Test with Talk Test" Is a Reliable Test to Monitor Cardiovascular Fitness in Patients with Minor Stroke

    DEFF Research Database (Denmark)

    Steen Krawcyk, Rikke; Vinther, Anders; Caesar Petersen, Nicolas

    2017-01-01

    variability may challenge currently used cardiovascular monitoring. The Graded Cycling Test with Talk Test is a submaximal exercise test independent of heart rate variability, shown reliable for patients with cardiac disease. METHODS: Patients diagnosed with lacunar stroke according to TOAST (Trial of Org...... a minor measurement error: 12.9 W for groups of patients (standard error of measurement, SEM95) and 18.3 W for individual patients (smallest real difference). CONCLUSION: The "Graded Cycling Test with Talk Test" is feasible and reliable for monitoring exercise effects in patients with lacunar stroke...... 10172 in Acute Stroke Treatment) criteria performed an incremental exercise test on a stationary bicycle with a 15 W (watt) increase in workload every minute. Toward the end of each incremental step, the patients recited a standardized text passage and subsequently were asked: "Are you still able...

  15. A Simple Student Laboratory on Osmotic Flow, Osmotic Pressure, and the Reflection Coefficient.

    Science.gov (United States)

    Feher, Joseph J.; Ford, George D.

    1995-01-01

    Describes a laboratory exercise containing a practical series of experiments that novice students can perform within two hours. The exercise provides a confirmation of van't Hoff's law while placing more emphasis on osmotic flow than pressure. Students can determine parameters such as the reflection coefficient which stress the interaction of both…

  16. Thallium-201 myocardial imaging in evaluation of asymptomatic individuals with ischaemic ST segment depression on exercise electrocardiogram

    International Nuclear Information System (INIS)

    Caralis, D.G.; Bailey, I.; Kennedy, H.L.; Pitt, B.

    1979-01-01

    This study showed that asymptomatic adults with normal physical examination, normal resting electrocardiogram, and normal routine laboratory evaluation who had a positive exercise electrocardiogram and abnormal exercise thallium-201 myocardial image had a very high probability of angiographically significant coronary artery disease. If, on the other hand, the exercise electrocardiogram was positive for 'ischaemic' ST segment changes, but the exercise thallium image was normal, the probability for coronary disease was low. The exercise electrocardiogram combined with thallium-201 myocardial image are safe non-invasive methods which can be performed on an out-patient basis. (author)

  17. An Infiltration Exercise for Introductory Soil Science

    Science.gov (United States)

    Barbarick, K. A.; Ippolito, J. A.; Butters, G.; Sorge, G. M.

    2005-01-01

    One of the largest challenges in teaching introductory soil science is explaining the dynamics of soil infiltration. To aid students in understanding the concept and to further engage them in active learning in the soils laboratory course, we developed an exercise using Decagon Mini-Disk Infiltrometers with a tension head (h[subscript o]) of 2 cm.…

  18. Guaiacol Peroxidase Zymography for the Undergraduate Laboratory

    Science.gov (United States)

    Wilkesman, Jeff; Castro, Diana; Contreras, Lellys M.; Kurz, Liliana

    2014-01-01

    This laboratory exercise presents a novel way to introduce undergraduate students to the specific detection of enzymatic activity by electrophoresis. First, students prepare a crude peroxidase extract and then analyze the homogenate via electrophoresis. Zymography, that is, a SDS-PAGE method to detect enzyme activity, is used to specifically…

  19. Accuracy in HIV Rapid Testing among Laboratory and Non-laboratory Personnel in Zambia: Observations from the National HIV Proficiency Testing System.

    Directory of Open Access Journals (Sweden)

    Sheila Mwangala

    Full Text Available Despite rapid task-shifting and scale-up of HIV testing services in high HIV prevalence countries, studies evaluating accuracy remain limited. This study aimed to assess overall accuracy level and factors associated with accuracy in HIV rapid testing in Zambia.Accuracy was investigated among rural and urban HIV testing sites participating in two annual national HIV proficiency testing (PT exercises conducted in 2009 (n = 282 sites and 2010 (n = 488 sites. Testers included lay counselors, nurses, laboratory personnel and others. PT panels of five dry tube specimens (DTS were issued to testing sites by the national reference laboratory (NRL. Site accuracy level was assessed by comparison of reported results to the expected results. Non-parametric rank tests and multiple linear regression models were used to assess variation in accuracy between PT cycles and between tester groups, and to examine factors associated with accuracy respectively.Overall accuracy level was 93.1% (95% CI: 91.2-94.9 in 2009 and 96.9% (95% CI: 96.1-97.8 in 2010. Differences in accuracy were seen between the tester groups in 2009 with laboratory personnel being more accurate than non-laboratory personnel, while in 2010 no differences were seen. In both PT exercises, lay counselors and nurses had more difficulties interpreting results, with more occurrences of false-negative, false-positive and indeterminate results. Having received the standard HIV rapid testing training and adherence to the national HIV testing algorithm were positively associated with accuracy.The study showed an improvement in tester group and overall accuracy from the first PT exercise to the next. Average number of incorrect test results per 1000 tests performed was reduced from 69 to 31. Further improvement is needed, however, and the national HIV proficiency testing system seems to be an important tool in this regard, which should be continued and needs to be urgently strengthened.

  20. Reliability of ultrasound grading traditional score and new global OMERACT-EULAR score system (GLOESS): results from an inter- and intra-reading exercise by rheumatologists.

    Science.gov (United States)

    Ventura-Ríos, Lucio; Hernández-Díaz, Cristina; Ferrusquia-Toríz, Diana; Cruz-Arenas, Esteban; Rodríguez-Henríquez, Pedro; Alvarez Del Castillo, Ana Laura; Campaña-Parra, Alfredo; Canul, Efrén; Guerrero Yeo, Gerardo; Mendoza-Ruiz, Juan Jorge; Pérez Cristóbal, Mario; Sicsik, Sandra; Silva Luna, Karina

    2017-12-01

    This study aims to test the reliability of ultrasound to graduate synovitis in static and video images, evaluating separately grayscale and power Doppler (PD), and combined. Thirteen trained rheumatologist ultrasonographers participated in two separate rounds reading 42 images, 15 static and 27 videos, of the 7-joint count [wrist, 2nd and 3rd metacarpophalangeal (MCP), 2nd and 3rd interphalangeal (IPP), 2nd and 5th metatarsophalangeal (MTP) joints]. The images were from six patients with rheumatoid arthritis, performed by one ultrasonographer. Synovitis definition was according to OMERACT. Scoring system in grayscale, PD separately, and combined (GLOESS-Global OMERACT-EULAR Score System) were reviewed before exercise. Reliability intra- and inter-reading was calculated with Cohen's kappa weighted, according to Landis and Koch. Kappa values for inter-reading were good to excellent. The minor kappa was for GLOESS in static images, and the highest was for the same scoring in videos (k 0.59 and 0.85, respectively). Excellent values were obtained for static PD in 5th MTP joint and for PD video in 2nd MTP joint. Results for GLOESS in general were good to moderate. Poor agreement was observed in 3rd MCP and 3rd IPP in all kinds of images. Intra-reading agreement were greater in grayscale and GLOESS in static images than in videos (k 0.86 vs. 0.77 and k 0.86 vs. 0.71, respectively), but PD was greater in videos than in static images (k 1.0 vs. 0.79). The reliability of the synovitis scoring through static images and videos is in general good to moderate when using grayscale and PD separately or combined.

  1. RELIABILITY AND ACCURACY OF 10 HZ GPS DEVICES FOR SHORT-DISTANCE EXERCISE

    Directory of Open Access Journals (Sweden)

    Julen Castellano

    2011-03-01

    Full Text Available The use of GPS technology for training and research purposes requires a study of the reliability, validity and accuracy of the data generated (Petersen et al., 2009. To date, studies have focused on devices with a logging rate of 1 Hz and 5 Hz (Coutts and Duffield, 2010; Duffield et al., 2010; Jennings et al., 2010; MacLeod et al., 2009; Petersen et al., 2009; Portas et al., 2010, although it seems that more frequent sampling can increase the accuracy of the information provided by these devices (Jennings et al., 2010; MacLeod et al., 2009, Portas et al., 2010. However, we are unaware of any study of the reliability and accuracy of GPS devices using a sampling frequency of 10 Hz. Thus, the aim of the present research was to determine the reliability and accuracy of GPS devices operating at a sampling frequency of 10 Hz, in relation here to sprints of 15 m and 30 m and using both video and photoelectric cells.Nine trained male athletes participated in the study. Each participant completed 7 and 6 linear runs of 15 m and 30 m, respectively (n = 117, with only one GPS device being used per participant. Each repetition required them to complete the route as quickly as possible, with 1 min recovery between sets. Distance was monitored through the use of GPS devices (MinimaxX v4.0, Catapult Innovations, Melbourne, Australia operating at the above mentioned sampling frequency of 10 Hz. In addition, all tests were filmed with a video camera operating at a sampling frequency of 25 frames. Data were collected during what were considered to be good GPS conditions in terms of the weather and satellite conditions (number of satellites = 10.0 ± 0.2 and 10.3 ± 0.4 for sprints of 15 m and 30 m, respectively.Distance was measured using a tape measure. Electronic timing gates (TAG- Heuer, CP 520 Training model, Switzerland were used to obtain a criterion sprint time accurate to 0.01 s, with gates being placed at the beginning and end of the route (Petersen et

  2. Practical Application of Fundamental Concepts in Exercise Physiology

    Science.gov (United States)

    Ramsbottom R.; Kinch, R. F. T.; Morris, M. G.; Dennis, A. M.

    2007-01-01

    The collection of primary data in laboratory classes enhances undergraduate practical and critical thinking skills. The present article describes the use of a lecture program, running in parallel with a series of linked practical classes, that emphasizes classical or standard concepts in exercise physiology. The academic and practical program ran…

  3. Aerobic exercise intensity can be controlled by palpation of the radial artery DOI:10.5007/1980-0037.2010v12n3p186

    Directory of Open Access Journals (Sweden)

    Anselmo José Perez

    2010-01-01

    Full Text Available Heart rate (HR during exercise has been used for the control of aerobic exercise intensity. Palpation is the most popular and accessible method for this purpose. The responses obtained in laboratory tests are used for field application and are suggested to be similar. The objective of this study was to correlate the HR measures obtained by palpation and with a heart rate monitor (HRM in four sessions of aerobic exercise, and to compare the results obtained in the laboratory and in the field. Fifteen healthy young women underwent four sessions of aerobic training of 40 min each at a continuous load, including two sessions on a treadmill and two in the field (50-60% and 80-85% HRmax. During the sessions, HR was recorded minute-by-minute with an HRM (Polar Accurex and measured at 10-minute intervals by pulse palpation. There were significant differences in ∆HR values obtained by palpation and with the HRM between exercise sessions performed on the track and in the laboratory. Strong correlations (r = 0.95 and moderate to strong (r = 0.73 correlations were observed between palpation and HRM in the four sessions. HR during exercise obtained by palpation was underestimated by no more than 5%, but there were no significant differences in mean absolute HR measured by HRM and palpation. For the same exercise intensity, similar results are obtained in the field and laboratory. In addition, HR obtained by palpation of the radial artery immediately after exercise can be used for the control of aerobic exercise intensity.

  4. Use of a combined oxygen and carbon dioxide transcutaneous electrode in the estimation of gas exchange during exercise.

    OpenAIRE

    Sridhar, M K; Carter, R; Moran, F; Banham, S W

    1993-01-01

    BACKGROUND--Accurate and reliable measurement of gas exchange during exercise has traditionally involved arterial cannulation. Non-invasive devices to estimate arterial oxygen (O2) and carbon dioxide (CO2) tensions are now available. A method has been devised and evaluated for measuring gas exchange during exercise with a combined transcutaneous O2 and CO2 electrode. METHODS--Symptom limited exercise tests were carried out in 24 patients reporting effort intolerance and breathlessness. Exerci...

  5. [Laboratory accreditation and proficiency testing].

    Science.gov (United States)

    Kuwa, Katsuhiko

    2003-05-01

    ISO/TC 212 covering clinical laboratory testing and in vitro diagnostic test systems will issue the international standard for medical laboratory quality and competence requirements, ISO 15189. This standard is based on the ISO/IEC 17025, general requirements for competence of testing and calibration laboratories and ISO 9001, quality management systems-requirements. Clinical laboratory services are essential to patient care and therefore should be available to meet the needs of all patients and clinical personnel responsible for human health care. If a laboratory seeks accreditation, it should select an accreditation body that operates according to this international standard and in a manner which takes into account the particular requirements of clinical laboratories. Proficiency testing should be available to evaluate the calibration laboratories and reference measurement laboratories in clinical medicine. Reference measurement procedures should be of precise and the analytical principle of measurement applied should ensure reliability. We should be prepared to establish a quality management system and proficiency testing in clinical laboratories.

  6. Results of a Demonstration Assessment of Passive System Reliability Utilizing the Reliability Method for Passive Systems (RMPS)

    Energy Technology Data Exchange (ETDEWEB)

    Bucknor, Matthew; Grabaskas, David; Brunett, Acacia; Grelle, Austin

    2015-04-26

    Advanced small modular reactor designs include many advantageous design features such as passively driven safety systems that are arguably more reliable and cost effective relative to conventional active systems. Despite their attractiveness, a reliability assessment of passive systems can be difficult using conventional reliability methods due to the nature of passive systems. Simple deviations in boundary conditions can induce functional failures in a passive system, and intermediate or unexpected operating modes can also occur. As part of an ongoing project, Argonne National Laboratory is investigating various methodologies to address passive system reliability. The Reliability Method for Passive Systems (RMPS), a systematic approach for examining reliability, is one technique chosen for this analysis. This methodology is combined with the Risk-Informed Safety Margin Characterization (RISMC) approach to assess the reliability of a passive system and the impact of its associated uncertainties. For this demonstration problem, an integrated plant model of an advanced small modular pool-type sodium fast reactor with a passive reactor cavity cooling system is subjected to a station blackout using RELAP5-3D. This paper discusses important aspects of the reliability assessment, including deployment of the methodology, the uncertainty identification and quantification process, and identification of key risk metrics.

  7. Fourth Collaborative Materials Exercise of the Nuclear Forensics International Technical Working Group

    International Nuclear Information System (INIS)

    Schwantes, J.M.; Reilly, D.; Marsden, O.

    2018-01-01

    The Nuclear Forensics International Technical Working Group is a community of nuclear forensic practitioners who respond to incidents involving nuclear and other radioactive material out of regulatory control. The Group is dedicated to advancing nuclear forensic science in part through periodic participation in materials exercises. The Group completed its fourth Collaborative Materials Exercise in 2015 in which laboratories from 15 countries and one multinational organization analyzed three samples of special nuclear material in support of a mock nuclear forensic investigation. This special section of the Journal for Radioanalytical and Nuclear Chemistry is devoted to summarizing highlights from this exercise. (author)

  8. Developing a new experimental system for an undergraduate laboratory exercise to teach theories of visuomotor learning.

    Science.gov (United States)

    Kasuga, Shoko; Ushiba, Junichi

    2014-01-01

    Humans have a flexible motor ability to adapt their movements to changes in the internal/external environment. For example, using arm-reaching tasks, a number of studies experimentally showed that participants adapt to a novel visuomotor environment. These results helped develop computational models of motor learning implemented in the central nervous system. Despite the importance of such experimental paradigms for exploring the mechanisms of motor learning, because of the cost and preparation time, most students are unable to participate in such experiments. Therefore, in the current study, to help students better understand motor learning theories, we developed a simple finger-reaching experimental system using commonly used laptop PC components with an open-source programming language (Processing Motor Learning Toolkit: PMLT). We found that compared to a commercially available robotic arm-reaching device, our PMLT accomplished similar learning goals (difference in the error reduction between the devices, P = 0.10). In addition, consistent with previous reports from visuomotor learning studies, the participants showed after-effects indicating an adaptation of the motor learning system. The results suggest that PMLT can serve as a new experimental system for an undergraduate laboratory exercise of motor learning theories with minimal time and cost for instructors.

  9. Laboratory quality assurance and its role in the safeguards analytical laboratory evaluation (SALE) program

    International Nuclear Information System (INIS)

    Delvin, W.L.; Pietri, C.E.

    1981-07-01

    Since the late 1960's, strong emphasis has been given to quality assurance in the nuclear industry, particularly to that part involved in nuclear reactors. This emphasis has had impact on the analytical chemistry laboratory because of the importance of analytical measurements in the certification and acceptance of materials used in the fabrication and construction of reactor components. Laboratory quality assurance, in which the principles of quality assurance are applied to laboratory operations, has a significant role to play in processing, fabrication, and construction programs of the nuclear industry. That role impacts not only process control and material certification, but also safeguards and nuclear materials accountability. The implementation of laboratory quality assurance is done through a program plan that specifies how the principles of quality assurance are to be applied. Laboratory quality assurance identifies weaknesses and deficiencies in laboratory operations and provides confidence in the reliability of laboratory results. Such confidence in laboratory measurements is essential to the proper evaluation of laboratories participating in the Safeguards Analytical Laboratory Evaluation (SALE) Program

  10. An analysis of laboratory activities found in "Applications In Biology/Chemistry: A Contextual Approach to Laboratory Science"

    Science.gov (United States)

    Haskins, Sandra Sue

    The purpose of this study was to quantitatively determine whether the material found in ABC promotes scientific inquiry through the inclusion of science process skills, and to quantitatively determine the type (experimental, comparative, or descriptive) and character (wet-lab, paper and pencil, model, or computer) of laboratory activities. The research design allowed for an examination of the frequency and type of science process skills required of students in 79 laboratory activities sampled from all 12 units utilizing a modified 33-item laboratory analysis inventory (LAI) (Germane et al, 1996). Interrater reliability for the science process skills was completed on 19 of the laboratory activities with a mean score of 86.1%. Interrater reliability for the type and character of the laboratory, on the same 19 laboratory activities, was completed with mean scores of 79.0% and 96.5%, respectively. It was found that all laboratory activities provide a prelaboratory activity. In addition, the science process skill category of student performance is required most often of students with the skill of learning techniques or manipulating apparatus occurring 99% of the time. The science process skill category observed the least was student planning and design, occurring only 3% of the time. Students were rarely given the opportunity to practice science process skills such as developing and testing hypotheses through experiments they have designed. Chi-square tests, applied at the .05 level of significance, revealed that there was a significant difference in the type of laboratory activities; comparative laboratory activities appeared more often (59%). In addition the character of laboratory activities, "wet-lab" activities appeared more often (90%) than any of the others.

  11. Exercise-induced asthma in a group of South African schoolchildren ...

    African Journals Online (AJOL)

    Objectives. The study was conducted to ascertain whether physical education teachers, using a peak flow meter, could reliably screen for exercise-induced asthma (EIA) in children during free running. Design, setting and subjects. The study was conducted using a convenience sample of male pupils between the ages of 12 ...

  12. Preferential type II muscle fiber damage from plyometric exercise.

    Science.gov (United States)

    Macaluso, Filippo; Isaacs, Ashwin W; Myburgh, Kathryn H

    2012-01-01

    Plyometric training has been successfully used in different sporting contexts. Studies that investigated the effect of plyometric training on muscle morphology are limited, and results are controversial with regard to which muscle fiber type is mainly affected. To analyze the skeletal muscle structural and ultrastructural change induced by an acute bout of plyometric exercise to determine which type of muscle fibers is predominantly damaged. Descriptive laboratory study. Research laboratory. Eight healthy, untrained individuals (age = 22 ± 1 years, height = 179.2 ± 6.4 cm, weight = 78.9 ± 5.9 kg). Participants completed an acute bout of plyometric exercise (10 sets of 10 squat-jumps with a 1-minute rest between sets). Blood samples were collected 9 days and immediately before and 6 hours and 1, 2, and 3 days after the acute intervention. Muscle samples were collected 9 days before and 3 days after the exercise intervention. Blood samples were analyzed for creatine kinase activity. Muscle biopsies were analyzed for damage using fluorescent and electron transmission microscopy. Creatine kinase activity peaked 1 day after the exercise bout (529.0 ± 317.8 U/L). Immunofluorescence revealed sarcolemmal damage in 155 of 1616 fibers analyzed. Mainly fast-twitch fibers were damaged. Within subgroups, 7.6% of type I fibers, 10.3% of type IIa fibers, and 14.3% of type IIx fibers were damaged as assessed by losses in dystrophin staining. Similar damage was prevalent in IIx and IIa fibers. Electron microscopy revealed clearly distinguishable moderate and severe sarcomere damage, with damage quantifiably predominant in type II muscle fibers of both the glycolytic and oxidative subtypes (86% and 84%, respectively, versus only 27% of slow-twitch fibers). We provide direct evidence that a single bout of plyometric exercise affected mainly type II muscle fibers.

  13. A Coastal Environment Field and Laboratory Activity for an Undergraduate Geomorphology Course

    Science.gov (United States)

    Ellis, Jean T.; Rindfleisch, Paul R.

    2006-01-01

    A field and laboratory exercise for an undergraduate geomorphology class is described that focuses on the beach. The project requires one day of fieldwork and two laboratory sessions. In the field, students measure water surface fluctuations (waves) with a pressure sensor, survey beach profiles, collect sediment samples, and observe the beach…

  14. FACTORIAL VALIDITY OF THE KOREAN VERSION OF THE EXERCISE DEPENDENCE SCALE-REVISED.

    Science.gov (United States)

    Shin, Kyulee; You, Sukkyung

    2015-12-01

    This study evaluated the psychometric properties of the Korean version of the 21-item Exercise Dependence Scale-Revised (EDS-R). The EDS-R was designed to measure the multidimensional aspects of exercise dependence symptoms such as withdrawal, continuance, tolerance, lack of control, reductions, time, and intention. Although the EDS-R has demonstrated sound psychometric properties, it has only been validated in Western samples. Cross-cultural validations of the instrument may increase the knowledge of exercise dependence. Therefore, this study aimed to contribute to the file by investigating the validity and utility of the construct of the EDS-R, using a non-Western sample. 402 adult participants who were over 18 years of age and who reported exercising at least once a week were asked to complete the EDS-R. The results from factor analyses supported that the seven-factor model of exercise dependence symptoms showed an adequate fit for both men and women. The EDS-R scores differentiated between samples, with varying amounts of exercise; 15.4% of the sample was classified as being at risk for exercise dependence. In sum, the results indicated that the EDS-R is a psychometrically reliable assessment tool for exercise dependence symptoms in Korea.

  15. NDE reliability and SAFT-UT final development

    International Nuclear Information System (INIS)

    Doctor, S.R.; Deffenbaugh, J.D.; Good, M.S.; Green, E.R.; Heasler, P.G.; Reid, L.D.; Simonen, F.A.; Spanner, J.C.; Taylor, T.T.; Vo, T.V.

    1990-01-01

    The Evaluation and Improvement of NDE Reliability for Inservice Inspection of Light Water Reactors (NDE Reliability) program at the Pacific Northwest Laboratory (PNL) was established by the US Nuclear Regulatory Commission (NRC) to determine the reliability of current inservice inspection (ISI) techniques and to develop recommendations that will ensure a suitably high inspection reliability. This is a progress report covering the programmatic work from October 1987 through September 1988. The program for Validation and Technology Transfer for SAFT-UT is designed to accomplish the final step of moving research results into beneficial application. Accomplishments for FY88 in Synthetic Aperture Focusing of Ultrasonic Test data (SAFT-UT) under this program are discussed in this paper. The information is treated under the copies of Code Activities, Field Validation, and Seminars. (orig.)

  16. Preliminary Validation and Reliability Testing of the Montreal Instrument for Cat Arthritis Testing, for Use by Veterinarians, in a Colony of Laboratory Cats

    Science.gov (United States)

    Klinck, Mary P.; Rialland, Pascale; Guillot, Martin; Moreau, Maxim; Frank, Diane; Troncy, Eric

    2015-01-01

    Simple Summary Feline osteoarthritis (OA) is challenging to diagnose. A pain scale was developed for use by veterinarians, in association with their physical examination, and tested for reliability and validity. The scale items were: Interaction with the examiner, Exploration of the room, Body Posture, Gait, Body Condition, condition of Coat and Claws, and abnormal Findings or Cat Reaction upon joint Palpation. Expert review supported the scale content. Two studies using laboratory-housed cats found the most promising results for Gait and Body Posture, in terms of distinguishing between OA and non-OA cats, repeatability of results, and correlations with objectively measured kinetics (weight-bearing). Abstract Subtle signs and conflicting physical and radiographic findings make feline osteoarthritis (OA) challenging to diagnose. A physical examination-based assessment was developed, consisting of eight items: Interaction, Exploration, Posture, Gait, Body Condition, Coat and Claws, (joint) Palpation–Findings, and Palpation–Cat Reaction. Content (experts) and face (veterinary students) validity were excellent. Construct validity, internal consistency, and intra- and inter-rater reliability were assessed via a pilot and main study, using laboratory-housed cats with and without OA. Gait distinguished OA status in the pilot (p = 0.05) study. In the main study, no scale item achieved statistically significant OA detection. Forelimb peak vertical ground reaction force (PVF) correlated inversely with Gait (Rhos = −0.38 (p = 0.03) to −0.41 (p = 0.02)). Body Posture correlated with Gait, and inversely with forelimb PVF at two of three time points (Rhos = −0.38 (p = 0.03) to −0.43 (p = 0.01)). Palpation (Findings, Cat Reaction) did not distinguish OA from non-OA cats. Palpation—Cat Reaction (Forelimbs) correlated inversely with forelimb PVF at two time points (Rhos = −0.41 (p = 0.02) to −0.41 (p = 0.01)), but scores were highly variable, and poorly reliable

  17. Laboratory training manual on the use of nuclear techniques in animal parasitology

    International Nuclear Information System (INIS)

    1982-01-01

    The Manual is designed for specialist training in the use of nuclear techniques in animal parasitology. The theoretical part contains a general introduction to experimental work in this field. Laboratory exercises are divided into Basic Exercises (17) and Applied Exercises (25) oriented to research in the immunology and pathogenesis of host-parasite interactions using radioisotopic methods and to disease management through the use of radiation-attenuated vaccines. The closing part contains a number of practical guidelines and data for work with radioisotopes in general and for the use of radioisotopic methods in animal parasitology

  18. Peer-review for selection of oral presentations for conferences: Are we reliable?

    Science.gov (United States)

    Deveugele, Myriam; Silverman, Jonathan

    2017-11-01

    Although peer-review for journal submission, grant-applications and conference submissions has been called 'a counter- stone of science', and even 'the gold standard for evaluating scientific merit', publications on this topic remain scares. Research that has investigated peer-review reveals several issues and criticisms concerning bias, poor quality review, unreliability and inefficiency. The most important weakness of the peer review process is the inconsistency between reviewers leading to inadequate inter-rater reliability. To report the reliability of ratings for a large international conference and to suggest possible solutions to overcome the problem. In 2016 during the International Conference on Communication in Healthcare, organized by EACH: International Association for Communication in Healthcare, a calibration exercise was proposed and feedback was reported back to the participants of the exercise. Most abstracts, as well as most peer-reviewers, receive and give scores around the median. Contrary to the general assumption that there are high and low scorers, in this group only 3 peer-reviewers could be identified with a high mean, while 7 has a low mean score. Only 2 reviewers gave only high ratings (4 and 5). Of the eight abstracts included in this exercise, only one abstract received a high mean score and one a low mean score. Nevertheless, both these abstracts received both low and high scores; all other abstracts received all possible scores. Peer-review of submissions for conferences are, in accordance with the literature, unreliable. New and creative methods will be needed to give the participants of a conference what they really deserve: a more reliable selection of the best abstracts. More raters per abstract improves the inter-rater reliability; training of reviewers could be helpful; providing feedback to reviewers can lead to less inter-rater disagreement; fostering negative peer-review (rejecting the inappropriate submissions) rather than a

  19. Association between sleep disorders, obesity, and exercise: a review

    Directory of Open Access Journals (Sweden)

    Hargens TA

    2013-03-01

    Full Text Available Trent A Hargens,1 Anthony S Kaleth,2 Elizabeth S Edwards,1 Katrina L Butner31Department of Kinesiology, James Madison University, Harrisonburg, VA, USA; 2Department of Kinesiology, Indiana University-Purdue University Indianapolis, Indianapolis, IN, USA; 3Laboratory for Health and Exercise Science, Department of Human Nutrition, Food and Exercise, Virginia Tech, Blacksburg, VA, USAAbstract: Decreased sleep duration and quality is associated with an increase in body weight and adiposity. Insomnia, obstructive sleep apnea, and restless legs syndrome are three of the most prevalent types of sleep disorder that lead to an increased risk for numerous chronic health conditions. Various studies have examined the impact of these sleep disorders on obesity, and are an important link in understanding the relationship between sleep disorders and chronic disease. Physical activity and exercise are important prognostic tools in obesity and chronic disease, and numerous studies have explored the relationship between obesity, sleep disorders, and exercise. As such, this review will examine the relationship between sleep disorders and obesity. In addition, how sleep disorders may impact the exercise response and how exercise may impact patient outcomes with regard to sleep disorders will also be reviewed.Keywords: obesity, sleep disorders, obstructive sleep apnea, insomnia

  20. Right ventricular oxygen supply/demand balance in exercising dogs.

    Science.gov (United States)

    Hart, B J; Bian, X; Gwirtz, P A; Setty, S; Downey, H F

    2001-08-01

    This is the first investigation of right ventricular (RV) myocardial oxygen supply/demand balance in a conscious animal. A novel technique developed in our laboratory was used to collect right coronary (RC) venous blood samples from seven instrumented, conscious dogs at rest and during graded treadmill exercise. Contributions of the RV oxygen extraction reserve and the RC flow reserve to exercise-induced increases in RV oxygen demand were measured. Strenuous exercise caused a 269% increase in RV oxygen consumption. Expanded arteriovenous oxygen content difference (A-V(Delta)O2) provided 58% of this increase in oxygen demand, and increased RC blood flow (RCBF) provided 42%. At less strenuous exercise, expanded A-V(Delta)O2 provided 60-80% of the required oxygen, and increases in RCBF were small and driven by increased aortic pressure. RC resistance fell only at strenuous exercise after the extraction reserve had been mobilized. Thus RC resistance was unaffected by large decreases in RC venous PO2 until an apparent threshold at 20 mmHg was reached. Comparisons of RV findings with published left ventricular data from exercising dogs demonstrated that increased O2 demand of the left ventricle is met primarily by increasing coronary flow, whereas increased O2 extraction makes a greater contribution to RV O2 supply.

  1. Accuracy and Reliability of Peer Assessment of Athletic Training Psychomotor Laboratory Skills

    Science.gov (United States)

    Marty, Melissa C.; Henning, Jolene M.; Willse, John T.

    2010-01-01

    Abstract Context: Peer assessment is defined as students judging the level or quality of a fellow student's understanding. No researchers have yet demonstrated the accuracy or reliability of peer assessment in athletic training education. Objective: To determine the accuracy and reliability of peer assessment of athletic training students' psychomotor skills. Design: Cross-sectional study. Setting: Entry-level master's athletic training education program. Patients or Other Participants: First-year (n  =  5) and second-year (n  =  8) students. Main Outcome Measure(s): Participants evaluated 10 videos of a peer performing 3 psychomotor skills (middle deltoid manual muscle test, Faber test, and Slocum drawer test) on 2 separate occasions using a valid assessment tool. Accuracy of each peer-assessment score was examined through percentage correct scores. We used a generalizability study to determine how reliable athletic training students were in assessing a peer performing the aforementioned skills. Decision studies using generalizability theory demonstrated how the peer-assessment scores were affected by the number of participants and number of occasions. Results: Participants had a high percentage of correct scores: 96.84% for the middle deltoid manual muscle test, 94.83% for the Faber test, and 97.13% for the Slocum drawer test. They were not able to reliably assess a peer performing any of the psychomotor skills on only 1 occasion. However, the ϕ increased (exceeding the 0.70 minimal standard) when 2 participants assessed the skill on 3 occasions (ϕ  =  0.79) for the Faber test, with 1 participant on 2 occasions (ϕ  =  0.76) for the Slocum drawer test, and with 3 participants on 2 occasions for the middle deltoid manual muscle test (ϕ  =  0.72). Conclusions: Although students did not detect all errors, they assessed their peers with an average of 96% accuracy. Having only 1 student assess a peer performing certain psychomotor skills was

  2. Cognitive Load in Voice Therapy Carry-Over Exercises

    DEFF Research Database (Denmark)

    Iwarsson, Jenny; Morris, David Jackson; Balling, Laura Winther

    2017-01-01

    Purpose The cognitive load generated by online speech production may vary with the nature of the speech task. This article examines 3 speech tasks used in voice therapy carry-over exercises, in which a patient is required to adopt and automatize new voice behaviors, ultimately in daily spontaneous...... to automation of revised speech behavior and that self-reports may be a reliable index of cognitive load....

  3. Perceptions of exercise screening among older adults.

    Science.gov (United States)

    Stathokostas, Liza; Petrella, Andrea F M; Blunt, Wendy; Petrella, Robert J

    2018-06-01

    Prephysical activity screening is important for older adults' participating in physical activity. Unfortunately, many older adults face barriers to exercise participation and thus, may not complete proper physical activity screening. The purpose of this project was to conduct a thematic analysis of perceptions and experiences of community-dwelling older adults regarding prephysical activity screening (i.e., Get Active Questionnaire (GAQ) and a standardized exercise stress test). A convenience sample of adults (male n = 58, female n = 54) aged 75 ± 7 years living in the City of London, Ontario, Canada, was used. Participants completed a treadmill stress test and the GAQ at a research laboratory for community-based referrals. One week later, participants completed the GAQ again and were asked questions by a research assistant about their perceptions of the screening process. Thematic analysis of the responses was conducted. The results indicated that older adults view physical activity screening as acceptable, but not always necessary. Also, the experiences expressed by this sample of older adults indicated that physical activity screening can contribute to continued confidence (through reassurance) and can contribute to increased motivation (through yearly fitness results) in exercise participation. In conclusion, older adults may perceive screening as supportive in exercise adoption, if screening is simple, convenient, and supports older adults' motivation and confidence to exercise.

  4. EFFECT OF MUSIC ON ANAEROBIC EXERCISE PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Tülin Atan

    2013-01-01

    Full Text Available For years, mostly the effects of music on cardiorespiratory exercise performance have been studied, but a few studies have examined the effect of music on anaerobic exercise. The purpose of this study was to assess the effect of listening to music and its rhythm on anaerobic exercise: on power output, heart rate and the concentration of blood lactate. 28 male subjects were required to visit the laboratory on 6 occasions, each separated by 48 hours. Firstly, each subject performed the Running-based Anaerobic Sprint Test (RAST under 3 conditions on separate days: while listening to “slow rhythm music”, “fast rhythm music” or “no music”. 48 hours after the subjects completed RAST under 3 conditions, Wingate Anaerobic Power (WAN tests were performed under 3 music conditions. The order of the 3 conditions (slow music, fast music and no music was selected randomly to prevent an order effect. Results showed no significant differences between 3 conditions in anaerobic power assessments, heart rate or blood lactate (p>0.05. On the basis of these results it can be said that music cannot improve anaerobic performance. The type of music had no impact on power outputs during RAST and WAN exercise. As a conclusion, listening to music and its rhythm cannot enhance anaerobic performance and cannot change the physiological response to supramaximal exercise.

  5. Vibrotactile Stimulation as an Instructor for Mimicry-Based Physical Exercise

    Directory of Open Access Journals (Sweden)

    Jani Lylykangas

    2015-01-01

    Full Text Available The present aim was to investigate functionality of vibrotactile stimulation in mimicry-based behavioral regulation during physical exercise. Vibrotactile stimuli communicated instructions from an instructor to an exerciser to perform lower extremity movements. A wireless prototype was tested first in controlled laboratory conditions (Study 1 and was followed by a user study (Study 2 that was conducted in a group exercise situation for elderly participants with a new version of the system with improved construction and extended functionality. The results of Study 1 showed that vibrotactile instructions were successful in both supplementing and substituting visual knee lift instructions. Vibrotactile stimuli were accurately recognized, and exercise with the device received affirmative ratings. Interestingly, tactile stimulation appeared to stabilize acceleration magnitude of the knee lifts in comparison to visual instructions. In Study 2 it was found that user experience of the system was mainly positive by both the exercisers and their instructors. For example, exercise with vibrotactile instructions was experienced as more motivating than conventional exercise session. Together the results indicate that tactile instructions could increase possibilities for people having difficulties in following visual and auditory instructions to take part in mimicry-based group training. Both studies also revealed development areas that were primarily related to a slight delay in triggering the vibrotactile stimulation.

  6. First-year Engineering Education with the Creative Electrical Engineering Laboratory

    Science.gov (United States)

    Tsukamoto, Takehiko; Sugito, Tetsumasa; Ozeki, Osamu; Ushiroda, Sumio

    The Department of Electrical and Electronic Engineering in Toyota National College of Technology has put great emphasis on fundamental subjects. We introduced the creative electrical engineering laboratory into the first-year engineering education since 1998. The laboratory concentrates on the practice exercise. The final questionnaire of students showed that our first-year education is very effective to promote students motivation and their scholastic ability in engineering.

  7. Quality assessment of shoulder plyometric exercises: Examining the relationship to scapular muscle activity.

    Science.gov (United States)

    Calé-Benzoor, Maya; Maenhout, Annelies; Arnon, Michal; Tenenbaum, Gershon; Werrin, Mia; Cools, Ann

    2017-07-01

    The purpose of the study was to evaluate performance quality of shoulder plyometric exercises, and examine the relationship to scapular muscle activation during an intense exercise bout. Observational study. University laboratory. 32 healthy university students (male/female: 14/18) volunteers. Subjects performed 10 plyometric exercises. Surface EMG of upper (UT), middle (MT) and lower (LT) trapezius and serratus anterior (SA) was registered. A quality assessment questionnaire was administered at the beginning and end of the exercise bout. Muscle activation at the beginning and end was evaluated by t-test. Mixed repeated measures ANOVA was conducted to test the effects of criterion-quality, time, muscles, exercises, and their interactions. Increased EMG activation was noted in 34/40 cases, (21/40 significant (p plyometric exercises. Ability to keep a consistent arc of motion was the most sensitive marker of decline of performance quality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Correlation between physiological variables and rate of perceived exertion during a water exercises classes

    Directory of Open Access Journals (Sweden)

    M. Olkoski

    2014-09-01

    Conclusion: HR and [Lac] are alternative measures because they are easily determined, in addition to being the most reliable parameters for prescribing and controlling the intensity in water exercise classes in young women.

  9. GHEP-ISFG collaborative exercise on mixture profiles (GHEP-MIX06). Reporting conclusions: Results and evaluation.

    Science.gov (United States)

    Barrio, P A; Crespillo, M; Luque, J A; Aler, M; Baeza-Richer, C; Baldassarri, L; Carnevali, E; Coufalova, P; Flores, I; García, O; García, M A; González, R; Hernández, A; Inglés, V; Luque, G M; Mosquera-Miguel, A; Pedrosa, S; Pontes, M L; Porto, M J; Posada, Y; Ramella, M I; Ribeiro, T; Riego, E; Sala, A; Saragoni, V G; Serrano, A; Vannelli, S

    2018-07-01

    One of the main goals of the Spanish and Portuguese-Speaking Group of the International Society for Forensic Genetics (GHEP-ISFG) is to promote and contribute to the development and dissemination of scientific knowledge in the field of forensic genetics. Due to this fact, GHEP-ISFG holds different working commissions that are set up to develop activities in scientific aspects of general interest. One of them, the Mixture Commission of GHEP-ISFG, has organized annually, since 2009, a collaborative exercise on analysis and interpretation of autosomal short tandem repeat (STR) mixture profiles. Until now, six exercises have been organized. At the present edition (GHEP-MIX06), with 25 participant laboratories, the exercise main aim was to assess mixture profiles results by issuing a report, from the proposal of a complex mock case. One of the conclusions obtained from this exercise is the increasing tendency of participating laboratories to validate DNA mixture profiles analysis following international recommendations. However, the results have shown some differences among them regarding the edition and also the interpretation of mixture profiles. Besides, although the last revision of ISO/IEC 17025:2017 gives indications of how results should be reported, not all laboratories strictly follow their recommendations. Regarding the statistical aspect, all those laboratories that have performed statistical evaluation of the data have employed the likelihood ratio (LR) as a parameter to evaluate the statistical compatibility. However, LR values obtained show a wide range of variation. This fact could not be attributed to the software employed, since the vast majority of laboratories that performed LR calculation employed the same software (LRmixStudio). Thus, the final allelic composition of the edited mixture profile and the parameters employed in the software could explain this data dispersion. This highlights the need, for each laboratory, to define through internal

  10. Vertebrate Osmoregulation: A Student Laboratory Exercise Using Teleost Fish

    Science.gov (United States)

    Boily P.; Rees, B. B.; Williamson, L. A. C.

    2007-01-01

    Here, we describe a laboratory experiment as part of an upper-level vertebrate physiology course for biology majors to investigate the physiological response of vertebrates to osmoregulatory challenges. The experiment involves measuring plasma osmolality and Na[superscript +] -K[superscript +] -ATPase activity in gill tissue of teleost fish…

  11. Teaching Acid/Base Physiology in the Laboratory

    Science.gov (United States)

    Friis, Ulla G.; Plovsing, Ronni; Hansen, Klaus; Laursen, Bent G.; Wallstedt, Birgitta

    2010-01-01

    Acid/base homeostasis is one of the most difficult subdisciplines of physiology for medical students to master. A different approach, where theory and practice are linked, might help students develop a deeper understanding of acid/base homeostasis. We therefore set out to develop a laboratory exercise in acid/base physiology that would provide…

  12. Using implicit attitudes of exercise importance to predict explicit exercise dependence symptoms and exercise behaviors.

    Science.gov (United States)

    Forrest, Lauren N; Smith, April R; Fussner, Lauren M; Dodd, Dorian R; Clerkin, Elise M

    2016-01-01

    "Fast" (i.e., implicit) processing is relatively automatic; "slow" (i.e., explicit) processing is relatively controlled and can override automatic processing. These different processing types often produce different responses that uniquely predict behaviors. In the present study, we tested if explicit, self-reported symptoms of exercise dependence and an implicit association of exercise as important predicted exercise behaviors and change in problematic exercise attitudes. We assessed implicit attitudes of exercise importance and self-reported symptoms of exercise dependence at Time 1. Participants reported daily exercise behaviors for approximately one month, and then completed a Time 2 assessment of self-reported exercise dependence symptoms. Undergraduate males and females (Time 1, N = 93; Time 2, N = 74) tracked daily exercise behaviors for one month and completed an Implicit Association Test assessing implicit exercise importance and subscales of the Exercise Dependence Questionnaire (EDQ) assessing exercise dependence symptoms. Implicit attitudes of exercise importance and Time 1 EDQ scores predicted Time 2 EDQ scores. Further, implicit exercise importance and Time 1 EDQ scores predicted daily exercise intensity while Time 1 EDQ scores predicted the amount of days exercised. Implicit and explicit processing appear to uniquely predict exercise behaviors and attitudes. Given that different implicit and explicit processes may drive certain exercise factors (e.g., intensity and frequency, respectively), these behaviors may contribute to different aspects of exercise dependence.

  13. Reliability of heart rate variability threshold and parasympathetic reactivation after a submaximal exercise test

    Directory of Open Access Journals (Sweden)

    Carlos Janssen Gomes da Cruz

    Full Text Available Abstract The objective of this study was to evaluate reproducibility of heart rate variability threshold (HRVT and parasympathetic reactivation in physically active men (n= 16, 24.3 ± 5.1 years. During the test, HRVT was assessed by SD1 and r-MSSD dynamics. Immediately after exercise, r-MSSD was analyzed in segments of 60 seconds for a period of five minutes. High absolute and relatively reproducible analysis of HRVT were observed, as assessed by SD1 and r-MSSD dynamics (ICC = 0.92, CV = 10.8, SEM = 5.8. During the recovery phase, a moderate to high reproducibility was observed for r-MSSD from the first to the fifth minute (ICC = 0.69-0.95, CV = 7.5-14.2, SEM = 0.07-1.35. We conclude that HRVT and r-MSSD analysis after a submaximal stress test are highly reproducible measures that might be used to assess the acute and chronic effects of exercise training on cardiac autonomic modulation during and/or after a submaximal stress test.

  14. Psychometric Properties of the Iranian Version of the Behavioral Regulation in Exercise Questionnaire-2 (BREQ-2

    Directory of Open Access Journals (Sweden)

    Alireza Hidarnia

    2011-12-01

    Full Text Available Background: The Behavioral Regulation in Exercise Questionnaire (BREQ and the BREQ-2 are the most commonly used measures of behavioural regulation in exercise psychology. The purpose of the study was to assess the validity and reliability of the Iranian version of the BREQ-2 on a sample of university students.Methods: The BREQ-2 was translated into Persian by qualified experts and the psychometric properties of the instrument were assessed. Content validity was established, using a panel of 12 Iranian experts in the areas of health education, psychology, and exercise. Construct validity was assessed via confirmatory factor analysis (CFA, using LISREL 8.80 (N = 418. The reliability of the BREQ-2 was assessed, using a 2-week test-retest to establish its stability and Cronbach’s Alpha to estimate its internal consistency.Results: The Iranian version of the BREQ-2 was slightly modified to improve content validity. Primary results of confirmatory factor analysis did not fully support the 5-factor uncorrelated model. The model was modified; and the fit indices indicated that the 5-factor correlated model was the best fit. The scale was found to have acceptable internal consistency (α > 0.7 and test-retest reliability (intra-class correlation coefficient [ICC] > 0.80.Conclusion: The Iranian BREQ-2 has acceptable validity and reliability in the study sample and may be used in relevant studies to assess behavioural regulation in similar samples.

  15. Dose-Response Effects of Exercise Duration and Recovery on Cognitive Functioning.

    Science.gov (United States)

    Crush, Elizabeth A; Loprinzi, Paul D

    2017-12-01

    We examined the effects of different acute exercise durations and recovery periods on cognitive function in a counterbalanced, cross-over randomized controlled experiment. We placed 352 participants, aged 18 to 35 years into one of 16 experimental groups. Each participant visited the laboratory twice, separated by a 1-week washout period. Either Visit 1 or 2 consisted of an acute bout of moderate-intensity treadmill exercise (10, 20, 30, 45, or 60 minutes) followed by a period of rest (5, 15, or 30 minutes) before taking a set of five cognitive tests; the other visit consisted only of completing the cognitive tests (no exercise). Cognitive tests sampled multiple cognitive parameters, including reasoning, concentration, memory, attention, and planning. We found that a short recovery period (i.e., 5 minutes) may have a less favorable effect on planning ability but may be beneficial for memory. In addition, for various exercise durations and recovery periods, a Group × Time × Resting (nonexercise) A cognitive interaction effect was observed such that for both memory and inhibitory cognitive ability, acute exercise (vs. no exercise) had an enhancement effect for those with lower resting cognitive functioning. The length of the acute exercise recovery period and resting cognitive ability most influenced the association between exercise and cognitive function.

  16. Clay Caterpillars: A Tool for Ecology & Evolution Laboratories

    Science.gov (United States)

    Barber, Nicholas A.

    2012-01-01

    I present a framework for ecology and evolution laboratory exercises using artificial caterpillars made from modeling clay. Students generate and test hypotheses about predation rates on caterpillars that differ in appearance or "behavior" to understand how natural selection by predators shapes distribution and physical characteristics of…

  17. Gearbox Reliability Collaborative High Speed Shaft Tapered Roller Bearing Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Keller, J.; Guo, Y.; McNiff, B.

    2013-10-01

    The National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) is a project investigating gearbox reliability primarily through testing and modeling. Previous dynamometer testing focused upon acquiring measurements in the planetary section of the test gearbox. Prior to these tests, the strain gages installed on the planetary bearings were calibrated in a load frame.

  18. Laboratory course on silicon strip detectors

    International Nuclear Information System (INIS)

    Montano, Luis M

    2005-01-01

    In this laboratory course we present an elementary introduction to the characteristics and applications of silicon detectors in High-Energy Physics, through performing some measurements which give an overview of the properties of these detectors as position resolution. The principles of operation are described in the activities the students have to develop together with some exercises to reinforce their knowledge on these devices

  19. Photovoltaic module certification/laboratory accreditation criteria development

    Energy Technology Data Exchange (ETDEWEB)

    Osterwald, C.R. [National Renewable Energy Lab., Golden, CO (United States); Hammond, R.L.; Wood, B.D.; Backus, C.E.; Sears, R.L. [Arizona State Univ., Tempe, AZ (United States); Zerlaut, G.A. [SC-International Inc., Phoenix, AZ (United States); D`Aiello, R.V. [RD Associates, Tempe, AZ (United States)

    1995-04-01

    This document provides an overview of the structure and function of typical product certification/laboratory accreditation programs. The overview is followed by a model program which could serve as the basis for a photovoltaic (PV) module certification/laboratory accreditation program. The model covers quality assurance procedures for the testing laboratory and manufacturer, third-party certification and labeling, and testing requirements (performance and reliability). A 30-member Criteria Development Committee was established to guide, review, and reach a majority consensus regarding criteria for a PV certification/laboratory accreditation program. Committee members represented PV manufacturers, end users, standards and codes organizations, and testing laboratories.

  20. Inter-laboratory exercise with an aim to compare methods for "9"0Sr and "2"3"9","2"4"0Pu determination in environmental soil samples

    International Nuclear Information System (INIS)

    Jixin Qiao; Per Roos; Salminen-Paatero, Susanna; Stina Holmgren Rondahl; Lagerkvist, Petra; Bourgeaux-Goget, Marie; Stralberg, Elisabeth; Rameback, Henrik; Chalmers University of Technology, Gothenburg

    2017-01-01

    In order to deliver reliable results for a multitude of different scenarios, e.g. emergency preparedness, environmental monitoring, nuclear decommissioning and waste management, there is a constant process of method development in the field of radioanalytical chemistry. This work presents the results of a method comparison exercise aimed at quantifying "9"0Sr and "2"3"9","2"4"0Pu in environmental soil samples, with the intention of evaluating the performance and applicability of different methods. From the methods examined in this work, recommendations are given in order to find a radioanalytical measurement procedure, for "9"0Sr and "2"3"9","2"4"0Pu analysis, which is fit-for-purpose for a particular scenario. (author)

  1. Requirements for the accreditation of a calibration laboratory

    International Nuclear Information System (INIS)

    Palacios, T.A.; Peretti, M.M.

    1993-01-01

    CNEA's activity in calibration is recent but it has a significant development. To assure high quality results, activity must be sustained and improved from day to day. The calibrations laboratory was accredited before Laboratories Qualification Committee, thus adding reliability to its results and making it more competitive when compared to other laboratories not accredited. Among other services given are supervision and follow up of calibrations in laboratories, participation in interlaboratory assays together with other calibration laboratories and assessments on calibration aspects of measuring equipment. (author)

  2. EXERCISE IMPROVES SEXUAL FUNCTION IN WOMEN TAKING ANTIDEPRESSANTS: RESULTS FROM A RANDOMIZED CROSSOVER TRIAL

    Science.gov (United States)

    Lorenz, Tierney Ahrold; Meston, Cindy May

    2014-01-01

    Background In laboratory studies, exercise immediately before sexual stimuli improved sexual arousal of women taking antidepressants [1]. We evaluated if exercise improves sexual desire, orgasm, and global sexual functioning in women experiencing antidepressant-induced sexual side effects. Methods Fifty-two women who were reporting antidepressant sexual side effects were followed for 3 weeks of sexual activity only. They were randomized to complete either three weeks of exercise immediately before sexual activity (3×/week) or 3 weeks of exercise separate from sexual activity (3×/week). At the end of the first exercise arm, participants crossed to the other. We measured sexual functioning, sexual satisfaction, depression, and physical health. Results Exercise immediately prior to sexual activity significantly improved sexual desire and, for women with sexual dysfunction at baseline, global sexual function. Scheduling regular sexual activity significantly improved orgasm function; exercise did not increase this benefit. Neither regular sexual activity nor exercise significantly changed sexual satisfaction. Conclusions Scheduling regular sexual activity and exercise may be an effective tool for the behavioral management of sexual side effects of antidepressants. PMID:24754044

  3. Exercise and sleep in aging: emphasis on serotonin.

    Science.gov (United States)

    Melancon, M O; Lorrain, D; Dionne, I J

    2014-10-01

    Reductions in central serotonin activity with aging might be involved in sleep-related disorders in later life. Although the beneficial effects of aerobic exercise on sleep are not new, sleep represents a complex recurring state of unconsciousness involving many lines of transmitters which remains only partly clear despite intense ongoing research. It is known that serotonin released into diencephalon and cerebrum might play a key inhibitory role to help promote sleep, likely through an active inhibition of supraspinal neural networks. Several lines of evidence support the stimulatory effects of exercise on higher serotonergic pathways. Hence, exercise has proved to elicit acute elevations in forebrain serotonin concentrations, an effect that waned upon cessation of exercise. While adequate exercise training might lead to adaptations in higher serotonergic networks (desensitization of forebrain receptors), excessive training has been linked to serious brain serotonergic maladaptations accompanied by insomnia. Dietary supplementation of tryptophan (the only serotonin precursor) is known to stimulate serotonergic activity and promote sleep, whereas acute tryptophan depletion causes deleterious effects on sleep. Regarding sleep-wake regulation, exercise has proved to accelerate resynchronization of the biological clock to new light-dark cycles following imposition of phase shifts in laboratory animals. Noteworthy, the effect of increased serotonergic transmission on wake state appears to be biphasic, i.e. promote wake and thereafter drowsiness. Therefore, it might be possible that acute aerobic exercise would act on sleep by increasing activity of ascending brain serotonergic projections, though additional work is warranted to better understand the implication of serotonin in the exercise-sleep axis. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  4. A DNA Melting Exercise for a Large Laboratory Class

    Science.gov (United States)

    Levine, Lauren A.; Junker, Matthew; Stark, Myranda; Greenleaf, Dustin

    2015-01-01

    A simple and economical experimental setup is described that enables multiple individuals or groups within a laboratory class to measure the thermal melting of double stranded DNA simultaneously. The setup utilizes a basic spectrophotometer capable of measuring absorbance at 260 nm, UV plastic cuvettes, and a stirring hot plate. Students measure…

  5. Systems reliability analysis for the national ignition facility

    International Nuclear Information System (INIS)

    Majumdar, K.C.; Annese, C.E.; MacIntyre, A.T.; Sicherman, A.

    1996-01-01

    A Reliability, Availability and Maintainability (RAM) analysis was initiated for the National Ignition Facility (NIF). The NIF is an inertial confinement fusion research facility designed to achieve controlled thermonuclear reaction; the preferred site for the NIF is the Lawrence Livermore National Laboratory (LLNL). The NIF RAM analysis has three purposes: (1) to allocate top level reliability and availability goals for the systems, (2) to develop an operability model for optimum maintainability, and (3) to determine the achievability of the allocated goals of the RAM parameters for the NIF systems and the facility operation as a whole. An allocation model assigns the reliability and availability goals for front line and support systems by a top-down approach; reliability analysis uses a bottom-up approach to determine the system reliability and availability from component level to system level

  6. Hardware Evaluation of the Horizontal Exercise Fixture with Weight Stack

    Science.gov (United States)

    Newby, Nate; Leach, Mark; Fincke, Renita; Sharp, Carwyn

    2009-01-01

    HEF with weight stack seems to be a very sturdy and reliable exercise device that should function well in a bed rest training setting. A few improvements should be made to both the hardware and software to improve usage efficiency, but largely, this evaluation has demonstrated HEF's robustness. The hardware offers loading to muscles, bones, and joints, potentially sufficient to mitigate the loss of muscle mass and bone mineral density during long-duration bed rest campaigns. With some minor modifications, the HEF with weight stack equipment provides the best currently available means of performing squat, heel raise, prone row, bench press, and hip flexion/extension exercise in a supine orientation.

  7. Refining Measurement of Social Cognitive Theory Factors Associated with Exercise Adherence in Head and Neck Cancer Patients.

    Science.gov (United States)

    Rogers, Laura Q; Fogleman, Amanda; Verhulst, Steven; Bhugra, Mudita; Rao, Krishna; Malone, James; Robbs, Randall; Robbins, K Thomas

    2015-01-01

    Social cognitive theory (SCT) measures related to exercise adherence in head and neck cancer (HNCa) patients were developed. Enrolling 101 HNCa patients, psychometric properties and associations with exercise behavior were examined for barriers self-efficacy, perceived barriers interference, outcome expectations, enjoyment, and goal setting. Cronbach's alpha ranged from.84 to.95; only enjoyment demonstrated limited test-retest reliability. Subscales for barriers self-efficacy (motivational, physical health) and barriers interference (motivational, physical health, time, environment) were identified. Multiple SCT constructs were cross-sectional correlates and prospective predictors of exercise behavior. These measures can improve the application of the SCT to exercise adherence in HNCa patients.

  8. Reliability of a Cryoscopic Micro-Osmometer Using 15-µL Plasma Samples to Measure Hydration Status in Varied Environmental Conditions

    Science.gov (United States)

    Scanlan, Aaron T.; Richter-Stretton, Gina L.; Madueno, Maria C.; Borges, Nattai R.; Fenning, Andrew S.

    2017-01-01

    Measurement of plasma osmolality (P[subscript osm]) remains popular for assessing hydration status in exercise science. However, a controlled reliability assessment of micro-osmometry using small sample volumes to measure Posm remains to be performed. This study aimed to examine the reliability of a cryoscopic micro-osmometer requiring 15-µL…

  9. Theoretical Hammett Plot for the Gas-Phase Ionization of Benzoic Acid versus Phenol: A Computational Chemistry Lab Exercise

    Science.gov (United States)

    Ziegler, Blake E.

    2013-01-01

    Computational chemistry undergraduate laboratory courses are now part of the chemistry curriculum at many universities. However, there remains a lack of computational chemistry exercises available to instructors. This exercise is presented for students to develop skills using computational chemistry software while supplementing their knowledge of…

  10. Kegel Exercises

    Science.gov (United States)

    ... exercised my pelvic muscles ____ times. I spent ____ minutes exercising. At each exercise session, I squeezed my pelvic ... exercised my pelvic muscles ____ times. I spent ____ minutes exercising. At each exercise session, I squeezed my pelvic ...

  11. Forensic typing of autosomal SNPs with a 29 SNP-multiplex--results of a collaborative EDNAP exercise.

    Science.gov (United States)

    Sanchez, J J; Børsting, C; Balogh, K; Berger, B; Bogus, M; Butler, J M; Carracedo, A; Court, D Syndercombe; Dixon, L A; Filipović, B; Fondevila, M; Gill, P; Harrison, C D; Hohoff, C; Huel, R; Ludes, B; Parson, W; Parsons, T J; Petkovski, E; Phillips, C; Schmitter, H; Schneider, P M; Vallone, P M; Morling, N

    2008-06-01

    We report the results of an inter-laboratory exercise on typing of autosomal single nucleotide polymorphisms (SNP) for forensic genetic investigations in crime cases. The European DNA Profiling Group (EDNAP), a working group under the International Society for Forensic Genetics (ISFG), organised the exercise. A total of 11 European and one US forensic genetic laboratories tested a subset of a 52 SNP-multiplex PCR kit developed by the SNPforID consortium. The 52 SNP-multiplex kit amplifies 52 DNA fragments with 52 autosomal SNP loci in one multiplex PCR. The 52 SNPs are detected in two separate single base extension (SBE) multiplex reactions with 29 and 23 SNPs, respectively, using SNaPshot kit, capillary electrophoresis and multicolour fluorescence detection. For practical reasons, only the 29 SBE multiplex reaction was carried out by the participating laboratories. A total of 11 bloodstains on FTA cards including a sample of poor quality and a negative control were sent to the laboratories together with the essential reagents for the initial multiplex PCR and the multiplex SBE reaction. The total SNP locus dropout rate was 2.8% and more than 50% of the dropouts were observed with the poor quality sample. The overall rate of discrepant SNP allele assignments was 2.0%. Two laboratories reported 60% of all the discrepancies. Two laboratories reported all 29 SNP alleles in all 10 positive samples correctly. The results of the collaborative exercise were surprisingly good and demonstrate that SNP typing with SBE, capillary electrophoresis and multicolour detection methods can be developed for forensic genetics.

  12. Analysis of sodium valve reliability data at CREDO

    International Nuclear Information System (INIS)

    Bott, T.F.; Haas, P.M.

    1979-01-01

    The Centralized Reliability Data Organization (CREDO) has been established at Oak Ridge National Laboratory (ORNL) by the Department of Energy to provide a centralized source of data for reliability/maintainabilty analysis of advanced reactor systems. The current schedule calls for develoment of the data system at a moderate pace, with the first major distribution of data in late FY-1980. Continuous long-term collection of engineering, operating, and event data has been initiated at EBR-II and FFTF

  13. Physiotherapy exercise programmes: are instructional exercise sheets effective?

    Science.gov (United States)

    Smith, Jo; Lewis, Jeremy; Prichard, Diana

    2005-01-01

    Effective compliance with physiotherapy exercises is only possible if patients remember the exercises accurately. The purpose of this study was to assess how well elderly in-patients remembered simple physiotherapy exercises, by comparing the ability to accurately reproduce a set of exercises in a group of patients that had received a written exercise sheet, with a group that had not. The study also aimed to investigate the relationship between memory for exercises and cognition. Sixty-four in-patients in an acute hospital were taught 3 exercises. Half of the subjects were randomised to receive exercise sheets to reinforce the teaching (Group 1). The rest of the subjects did not receive this memory aid (Group 2). Two to three days later subjects were asked to demonstrate their exercises. The accurate recall of the exercises was scored using a new assessment scale with a maximum score of 24. The mean exercise score was 17.19 for group 1 (SD = 5.91) and 16.24 for Group 2 (SD = 6.01). There was no significant difference in exercise score between groups (Mann Whitney U test p = 0.44). There was a statistically significant small positive correlation between exercise score and cognition (tau = 0.263). The study showed that older adult in-patients do not remember physiotherapy exercises effectively after a single teaching session and that their memory is not significantly improved by provision of an exercise sheet.

  14. Using Model Organisms in an Undergraduate Laboratory to Link Genotype, Phenotype, and the Environment

    Science.gov (United States)

    Jacobs-McDaniels, Nicole L.; Maine, Eleanor M.; Albertson, R. Craig; Wiles, Jason R.

    2013-01-01

    We developed laboratory exercises using zebrafish ("Danio rerio") and nematodes ("Caenorhabditis elegans") for a sophomore-level Integrative Biology Laboratory course. Students examined live wildtype zebrafish at different stages of development and noted shifts occurring in response to "fgf8a" deficiency. Students were introduced to development in…

  15. Final Design for an International Intercomparison Exercise for Nuclear Accident Dosimetry at the DAF Using Godiva-IV: IER-148 CED-2 Report

    Energy Technology Data Exchange (ETDEWEB)

    Heinrichs, Dave [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Beller, Tim [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Burch, Jennifer [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Cummings, Rick [National Security Technologies, LLC. (NSTec), Mercury, NV (United States) Nevada National Security Site; Duluc, Matthieu [Inst. de Radioprotection et de Sûrete Nucleaire (ISRN), Fontenay-aux-Roses (France); Gadd, Milan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Goda, Joetta [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hickman, David [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); McAvoy, Doug [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Rathbone, Bruce [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sullivan, Randy [Savannah River Site (SRS), Aiken, SC (United States); Trompier, Francois [Inst. de Radioprotection et de Sûrete Nucleaire (ISRN), Fontenay-aux-Roses (France); Veinot, Ken [Y-12 National Security Complex, Oak Ridge, TN (United States); Ward, Dann [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Will, Rashelle [National Security Technologies, LLC. (NSTec), Mercury, NV (United States) Nevada National Security Site; Wilson, Chris [Atomic Weapons Establishment (AWE), Berkshire (United Kingdom); Zieziulewicz, Thomas [Knolls Atomic Power Lab. (KAPL), Niskayuna, NY (United States)

    2014-09-30

    This document is the Final Design (CED-2) Report for IER-148, “International Inter-comparison Exercise for Nuclear Accident Dosimetry at the DAF Using Godiva-IV.” The report describes the structure of the exercise consisting of three irradiations; identifies the participating laboratories and their points of contact; provides the details of all dosimetry elements and their placement in proximity to Godiva-IV on support stands or phantoms ; and lists the counting and spectroscopy equipment each laboratory will utilize in the Mercury NAD Lab. The exercise is tentatively scheduled for one week in August 2015.

  16. Traceability in laboratories; Trazabilidad en laboratorios

    Energy Technology Data Exchange (ETDEWEB)

    Palacios, Tulio [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Centro Atomico Constituyentes; Peretti, Matilde; Saravi, Margarita [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Centro Atomico Ezeiza

    1996-07-01

    The testing and/or calibration laboratories main concern in to obtain reliability in the results delivered, therefore the accuracy and precision should be guaranteed. The regulations with respect to the quality systems makes special mention to the traceability in the equipment and in the measurements. In order to obtain that goal the laboratories are organized in national as well as in international nets to maintain the traceability to the primary standards. In the present work will be given the example of a particular laboratory in this regard. (author)

  17. Bernese motive and goal inventory in exercise and sport: Validation of an updated version of the questionnaire.

    Science.gov (United States)

    Schmid, Julia; Gut, Vanessa; Conzelmann, Achim; Sudeck, Gorden

    2018-01-01

    Target group-specific intervention strategies are often called for in order to effectively promote exercise and sport. Currently, motives and goals are rarely included systematically in the design of interventions, despite the key role they play in well-being and adherence to exercise. The Bernese motive and goal inventory (BMZI) allows an individual diagnosis of motives and goals in exercise and sport in people in middle adulthood. The purpose of the present study was to elaborate on the original BMZI and to modify the questionnaire in order to improve its psychometric properties. The study is based on data from two samples (sample A: 448 employees of companies and authorities; sample B: 853 patients of a medical rehabilitation programme). We applied confirmatory factor analysis and exploratory structural equation modelling. Overall, both the original and the updated BMZI had an acceptable to good validity and a good reliability. However, the revised questionnaire had slightly better reliability. The updated BMZI consists of 23 items and covers the following motives and goals: Body/Appearance, Contact, Competition/Performance, Aesthetics, Distraction/Catharsis, Fitness and Health. It is recommended as an economical inventory for the individual diagnosis of important psychological conditions for exercise and sport.

  18. Comparison of Effects of Running and Playing Exercises on Differential Leucocyte Count in Young Elite Athletes

    Science.gov (United States)

    Cenikli, Abdullah

    2016-01-01

    The aims of the present research are to test the effects of running and playing exercises on leucocyte and differential leucocyte accounts, and to test the possible differences between running and playing exercises in terms of leucocyte accounts. They were thirty two male young soccer players. Participants arrived at the laboratory after a 12-hour…

  19. Test-retest reliability and four-week changes in cardiopulmonary fitness in stroke patients: evaluation using a robotics-assisted tilt table.

    Science.gov (United States)

    Saengsuwan, Jittima; Berger, Lucia; Schuster-Amft, Corina; Nef, Tobias; Hunt, Kenneth J

    2016-09-06

    Exercise testing devices for evaluating cardiopulmonary fitness in patients with severe disability after stroke are lacking, but we have adapted a robotics-assisted tilt table (RATT) for cardiopulmonary exercise testing (CPET). Using the RATT in a sample of patients after stroke, this study aimed to investigate test-retest reliability and repeatability of CPET and to prospectively investigate changes in cardiopulmonary outcomes over a period of four weeks. Stroke patients with all degrees of disability underwent 3 separate CPET sessions: 2 tests at baseline (TB1 and TB2) and 1 test at follow up (TF). TB1 and TB2 were at least 24 h apart. TB2 and TF were 4 weeks apart. A RATT equipped with force sensors in the thigh cuffs, a work rate estimation algorithm and a real-time visual feedback system was used to guide the patients' exercise work rate during CPET. Test-retest reliability and repeatability of CPET variables were analysed using paired t-tests, the intraclass correlation coefficient (ICC), the coefficient of variation (CoV), and Bland and Altman limits of agreement. Changes in cardiopulmonary fitness during four weeks were analysed using paired t-tests. Seventeen sub-acute and chronic stroke patients (age 62.7 ± 10.4 years [mean ± SD]; 8 females) completed the test sessions. The median time post stroke was 350 days. There were 4 severely disabled, 1 moderately disabled and 12 mildly disabled patients. For test-retest, there were no statistically significant differences between TB1 and TB2 for most CPET variables. Peak oxygen uptake, peak heart rate, peak work rate and oxygen uptake at the ventilatory anaerobic threshold (VAT) and respiratory compensation point (RCP) showed good to excellent test-retest reliability (ICC 0.65-0.94). For all CPET variables, CoV was 4.1-14.5 %. The mean difference was close to zero in most of the CPET variables. There were no significant changes in most cardiopulmonary performance parameters during the 4-week period

  20. Portrayals of food practices and exercise behavior in popular American films.

    Science.gov (United States)

    Bell, Robert A; Berger, Charles R; Cassady, Diana; Townsend, Marilyn S

    2005-01-01

    To describe depictions of food, alcohol, and exercise and sport in popular films. Content analysis of the 10 top-grossing films each year from 1991 to 2000 (N = 100 films). Coding reliabilities were assessed with Cohen's kappa. Research questions were addressed with basic descriptive statistics. Associations among variables were examined through a cross-tabulation procedure that corrects for the clustering of exercise and food depictions within movies. Food and drink appeared regularly in the films analyzed, typically as a background element or prop. On average, food appeared on the screen once every 4.2 minutes. The foods shown were most likely to be fats, oils, and sweets; fruits, vegetables, and dairy products were rarely seen. More than 20% of the food items shown were alcoholic beverages, which were nearly 2 times more likely to be ingested as nonalcohol food items. Planned exercise and sports appeared at a rate of about 2 incidents per hour. These activities rarely received explicit evaluation by characters. Films frequently portray foods and exercise. These depictions have the potential to cultivate beliefs about normative eating and exercise behavior, suggesting a need for public health professionals to encourage the media to offer healthier images.

  1. Assessment of the quality of test results from selected civil engineering material testing laboratories in Tanzania

    CSIR Research Space (South Africa)

    Mbawala, SJ

    2017-12-01

    Full Text Available Civil and geotechnical engineering material testing laboratories are expected to produce accurate and reliable test results. However, the ability of laboratories to produce accurate and reliable test results depends on many factors, among others...

  2. Intertester reliability of the talk test in a cardiac rehabilitation population

    DEFF Research Database (Denmark)

    Petersen, Annemette Krintel; Maribo, Thomas; Hjortdal, Vibeke Elisabeth

    2013-01-01

    PURPOSE: The validity of the Talk Test (TT) is well documented, but the reliability of the test is not clear. The aim of this study was to assess the absolute and relative intertester reliability of the TT in cardiac patients. METHODS: Cardiac patients (n = 64) who had completed an exercise...... randomized to tests. Workload in watts at the first negative stage of the TT was registered as the test result. Patients and physiotherapists were blinded to test results of the first test. Absolute reliability of the TT was assessed with Bland-Altman plot, standard error of measurement, and minimal...... detectable change. Relative reliability was assessed using the intraclass correlation coefficient (ICC). RESULTS: Mean difference in peak workload between test and retest was 0.8 W (95% CI: -4.8 to 3.3). Limit of agreement was estimated to be +31/-32 W. Standard error of measurement was 11 W (95% CI: 10...

  3. Supervised Exercise Training Counterbalances the Adverse Effects of Insulin Therapy in Overweight/Obese Subjects With Type 2 Diabetes

    OpenAIRE

    Balducci, Stefano; Zanuso, Silvano; Cardelli, Patrizia; Salerno, Gerardo; Fallucca, Sara; Nicolucci, Antonio; Pugliese, Giuseppe

    2011-01-01

    OBJECTIVE To examine the effect of supervised exercise on traditional and nontraditional cardiovascular risk factors in sedentary, overweight/obese insulin-treated subjects with type 2 diabetes from the Italian Diabetes Exercise Study (IDES). RESEARCH DESIGN AND METHODS The study randomized 73 insulin-treated patients to twice weekly supervised aerobic and resistance training plus structured exercise counseling (EXE) or to counseling alone (CON) for 12 months. Clinical and laboratory paramete...

  4. The Case for Laboratory Developed Procedures

    Directory of Open Access Journals (Sweden)

    Karen L. Kaul MD, PhD

    2017-07-01

    Full Text Available An explosion of knowledge and technology is revolutionizing medicine and patient care. Novel testing must be brought to the clinic with safety and accuracy, but also in a timely and cost-effective manner, so that patients can benefit and laboratories can offer testing consistent with current guidelines. Under the oversight provided by the Clinical Laboratory Improvement Amendments, laboratories have been able to develop and optimize laboratory procedures for use in-house. Quality improvement programs, interlaboratory comparisons, and the ability of laboratories to adjust assays as needed to improve results, utilize new sample types, or incorporate new mutations, information, or technologies are positive aspects of Clinical Laboratory Improvement Amendments oversight of laboratory-developed procedures. Laboratories have a long history of successful service to patients operating under Clinical Laboratory Improvement Amendments. A series of detailed clinical examples illustrating the quality and positive impact of laboratory-developed procedures on patient care is provided. These examples also demonstrate how Clinical Laboratory Improvement Amendments oversight ensures accurate, reliable, and reproducible testing in clinical laboratories.

  5. An Impact of Thermodynamic Processes in Human Bodies on Performance Reliability of Individuals

    Directory of Open Access Journals (Sweden)

    Smalko Zbigniew

    2015-01-01

    Full Text Available The article presents the problem of the influence of thermodynamic factors on human fallibility in different zones of thermal discomfort. Describes the processes of energy in the human body. Been given a formal description of the energy balance of the human body thermoregulation. Pointed to human reactions to temperature changes of internal and external environment, including reactions associated with exercise. The methodology to estimate and determine the reliability of indicators of human basal acting in different zones of thermal discomfort. The significant effect of thermodynamic factors on the reliability and security ofperson.

  6. Los Alamos National Laboratory plans for a laboratory microfusion facility

    International Nuclear Information System (INIS)

    Harris, D.B.

    1988-01-01

    Los Alamos National Laboratory is actively participating in the National Laboratory Microfusion Facility (LMF) Scoping Study. We are currently performing a conceptual design study of a krypton-fluoride laser system that appears to meet all of the diver requirements for the LMF. A new theory of amplifier module scaling has been developed recently and it appears that KrF amplifier modules can be scaled up to output energies much larger than thought possible a few years ago. By using these large amplifier modules, the reliability and availability of the system is increased and its cost and complexity is decreased. Final cost figures will be available as soon as the detailed conceptual design is complete

  7. Brain reactivity to visual food stimuli after moderate-intensity exercise in children.

    Science.gov (United States)

    Masterson, Travis D; Kirwan, C Brock; Davidson, Lance E; Larson, Michael J; Keller, Kathleen L; Fearnbach, S Nicole; Evans, Alyssa; LeCheminant, James D

    2017-09-19

    Exercise may play a role in moderating eating behaviors. The purpose of this study was to examine the effect of an acute bout of exercise on neural responses to visual food stimuli in children ages 8-11 years. We hypothesized that acute exercise would result in reduced activity in reward areas of the brain. Using a randomized cross-over design, 26 healthy weight children completed two separate laboratory conditions (exercise; sedentary). During the exercise condition, each participant completed a 30-min bout of exercise at moderate-intensity (~ 67% HR maximum) on a motor-driven treadmill. During the sedentary session, participants sat continuously for 30 min. Neural responses to high- and low-calorie pictures of food were determined immediately following each condition using functional magnetic resonance imaging. There was a significant exercise condition*stimulus-type (high- vs. low-calorie pictures) interaction in the left hippocampus and right medial temporal lobe (p visual food stimuli differently following an acute bout of exercise compared to a non-exercise sedentary session in 8-11 year-old children. Specifically, an acute bout of exercise results in greater activation to high-calorie and reduced activation to low-calorie pictures of food in both the left hippocampus and right medial temporal lobe. This study shows that response to external food cues can be altered by exercise and understanding this mechanism will inform the development of future interventions aimed at altering energy intake in children.

  8. The 1996 Radon Intercomparison Exercise at PSI

    International Nuclear Information System (INIS)

    Schuler, C.; Butterweck-Dempewolf, G.

    1997-05-01

    The 1996 Radon Intercomparison Exercise at PSI was organized by the PSI Reference Laboratory for Radon Gas Activity Concentration Measurements. A total of 14 laboratories, companies and institutions participated with radon gas detectors and measuring instruments. The detectors and instruments were exposed in the PSI radon chamber during seven days in a reference atmosphere with an average radon gas concentration of about 6000 Bqm -3 . Comparison of the results of electret ionization chambers, track etch detectors and measuring instruments with the PSI target value showed the criteria for traceability and reproducibility demanded by the Federal Office for Health for the acknowledgement of Swiss Radon Gas Measurement Laboratories to be fulfilled for all participants. Exposure of track etch detectors stored for more than one year demonstrated that this detector type can suffer sensitivity loss by a too long storage period. (author) figs., tabs., refs

  9. Effect of Fitness Qigong-Wuqinxi exercise on some physiological indexes of female college students

    Directory of Open Access Journals (Sweden)

    PAN Guojian

    2016-02-01

    Full Text Available To know the reaction and adaption of human body after taking Fitness Qigong-Wuqinxi exercise and promote the popularity of Fitness Qigong-Wuqinxi exercise in universities,especially in female college students who do not major in sports,we observed their gas metabolism indexes and heart rates and contrast body shape and some physical quality indexes before and after the regular exercise for 16 weeks.The results showed that the indexes of waist,BMI,back force,grip force,and proneness when sitting improved obviously.Although height,weight,abdominal skinfold thickness,body fate percentage didn′t have significant change,the development trend is toward the direction of health.After exercise for 16 weeks,the three indexes of lung ventilation (VE、VO2、VCO2 showed wave shape.It is obvious that Fitness Qigong-Wuqinxi exercise can obviously improve the body shape,physical quality,and the function of heart and lung.Also,the wave feature of the indexes of lung ventilation can adjust the cardiopulmonary function,so Fitness Qigong-Wuqinxi exercise is a new safe and reliable fitness program.

  10. The effect of morning exercise on mental health of female police employees

    Directory of Open Access Journals (Sweden)

    Hassani Mohammad

    2015-06-01

    Full Text Available       Background & Aims of the Study: According to the report of world health, organization mental disorder is one of the important causes of disability in the world and it can result in decrease in the success and advancement of employees. Thus, the purpose of this research is evaluation and comparison of mental health status and its related factors in female employees who take part in morning exercise and who are exempt in one of the police units. This is a descriptive-analytic and cross sectional study. Materials & Methods: The population of this research included 85 female employees who took part in morning exercise as one group and the other group included 65 inactive people who were ill and exempt from exercise. The measurement tool in the research was the Goldberg and Hiller questionnaire of mental health that was consisted of 28 questions. Various studies in the world and in Iran suggest the high validity and reliability of the GHQ-28 questionnaire. The validity of the questionnaire has been approved in more than 70 countries and its reliability has been estimated to be between 82% and 92% in different researches and in different social groups. The data were analyzed using the descriptive statistics (frequency, mean and standard of deviation and deduction statistics (independent t-test in SPSS 16 software. Results: Analysis of the research hypotheses at significant level (p<0.05 showed that morning exercise had significant effect on mental health and its subscales such as physical complaint, anxiety, social dysfunction and depression in employees. Moreover, a significant difference was observed by comparing the active and inactive groups in relation to mental health and its subscales. Conclusions: The results of the research show that the effect of exercise and physical activities on mental health can't be denied. According to the researches that have been done, exercise is effective in two aspects of physical and mental.       

  11. Biomedical mass spectrometry in today's and tomorrow's clinical microbiology laboratories

    NARCIS (Netherlands)

    A.F. van Belkum (Alex); M. Welker (Martin); M. Erhard (Marcel); S. Chatellier (Sonia)

    2012-01-01

    textabstractClinical microbiology is a conservative laboratory exercise where base technologies introduced in the 19th century remained essentially unaltered. High-tech mass spectrometry (MS) has changed that. Within a few years following its adaptation to microbiological diagnostics, MS has been

  12. Joint Sandia/NIOSH exercise on aerosol contamination using the BROOM tool.

    Energy Technology Data Exchange (ETDEWEB)

    Ramsey, James L., Jr. (.,; .); Melton, Brad; Finley, Patrick; Brockman, John; Peyton, Chad E.; Tucker, Mark David; Einfeld, Wayne; Brown, Gary Stephen; Griffith, Richard O.; Lucero, Daniel A.; Knowlton, Robert G.; McKenna, Sean Andrew; Ho, Pauline

    2006-06-01

    In February of 2005, a joint exercise involving Sandia National Laboratories (SNL) and the National Institute for Occupational Safety and Health (NIOSH) was conducted in Albuquerque, NM. The SNL participants included the team developing the Building Restoration Operations and Optimization Model (BROOM), a software product developed to expedite sampling and data management activities applicable to facility restoration following a biological contamination event. Integrated data-collection, data-management, and visualization software improve the efficiency of cleanup, minimize facility downtime, and provide a transparent basis for reopening. The exercise was held at an SNL facility, the Coronado Club, a now-closed social club for Sandia employees located on Kirtland Air Force Base. Both NIOSH and SNL had specific objectives for the exercise, and all objectives were met.

  13. Changing the way science is taught through gamified laboratories

    DEFF Research Database (Denmark)

    Bonde, Mads; Makransky, G.; Wandall, J.

    2015-01-01

    A large proportion of high school and college students indicate that they have little interest in science, and many graduate with marginal science competencies. However, laboratory exercises, usually the most engaging part of science courses, tend to be expensive, time consuming and occasionally...... the crime-scene case in an introductory, college-level, life science course was conducted revealed that a gamified laboratory simulation can significantly increase both learning outcomes and motivation levels when compared with, and particularly when combined with, traditional teaching....

  14. The reliability of point-of-care prothrombin time testing. A comparison of CoaguChek S and XS INR measurements with hospital laboratory monitoring.

    LENUS (Irish Health Repository)

    Ryan, F

    2010-02-01

    The development of point-of-care (POC) testing devices enables patients to test their own international normalized ratio (INR) at home. However, previous studies have shown that when compared with clinical laboratory values, statistically significant differences may occur between the two methods of INR measurement. The aim of this study was to evaluate the accuracy of the CoaguChek S and XS POC meters relative to clinical laboratory measurements. As part of a randomized, crossover patient self-testing (PST) study at Cork University Hospital, patients were randomized to 6 months PST or 6 months routine care by the anticoagulation management service. During the PST arm of the study, patients measured their INR at home using the CoaguChek S or XS POC meter. External quality control was performed at enrollment, 2 months and 4 months by comparing the POC measured INR with the laboratory determined value. One hundred and fifty-one patients provided 673 paired samples. Good correlation was shown between the two methods of determination (r = 0.91), however, statistically significant differences did occur. A Bland-Altman plot illustrated good agreement of INR values between 2.0 and 3.5 INR units but there was increasing disagreement as the INR rose above 3.5. Eighty-seven per cent of all dual measurements were within the recommended 0.5 INR units of each other. This study adds to the growing evidence that POC testing is a reliable and safe alternative to hospital laboratory monitoring but highlights the importance of external quality control when these devices are used for monitoring oral anticoagulation.

  15. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    International Nuclear Information System (INIS)

    Baumgartner, A.; Maringer, F.J.; Michai, P.; Kreuziger, M.

    2006-01-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  16. Forensic ancestry analysis with two capillary electrophoresis ancestry informative marker (AIM) panels

    DEFF Research Database (Denmark)

    Santos, C; Fondevila, M; Ballard, D

    2015-01-01

    that analyzes the genotype data alongside calculation of Bayes likelihood ratios. Exercise results indicated consistent genotyping performance from both tests, reaching a particularly high level of reliability for the Indel test. SNP genotyping gave 93.5% concordance (compared to the organizing laboratory...... relationship between input DNA and signal strength as each marker is detected with a single dye, so mixed DNA is more reliably detected. We report the results of a collaborative inter-laboratory exercise of 19 participants (15 from the EDNAP European DNA Profiling group) that assessed a 34-plex SNP test using...... the correct ancestry to the other samples using Snipper, with the exception of one laboratory with SNP miscalls that incorrectly assigned ancestry of two samples and did not obtain informative likelihood ratios for a third. Therefore, successful ancestry assignments were achieved by participants in 92 of 95...

  17. Validity of a Newly-Designed Rectilinear Stepping Ergometer Submaximal Exercise Test to Assess Cardiorespiratory Fitness

    OpenAIRE

    Rubin Zhang, Likui Zhan, Shaoming Sun, Wei Peng, Yining Sun

    2017-01-01

    The maximum oxygen uptake (V̇O2 max), determined from graded maximal or submaximal exercise tests, is used to classify the cardiorespiratory fitness level of individuals. The purpose of this study was to examine the validity and reliability of the YMCA submaximal exercise test protocol performed on a newly-designed rectilinear stepping ergometer (RSE) that used up and down reciprocating vertical motion in place of conventional circular motion and giving precise measurement of workload, to det...

  18. New method for presenting offsite radiological monitoring data during emergency preparedness exercises

    International Nuclear Information System (INIS)

    Moeller, M.P.; Martin, G.F.; Hickey, E.E.; Jamison, J.D.

    1986-09-01

    As scenarios for exercises become more complicated and flexible to challenge emergency response personnel, improved means of presenting data must be developed. To provide maximum realism and free play during an exercise, staff at the Pacific Northwest Laboratory (PNL) have recently devised a simple method of presenting realistic radiological field monitoring information for a range of possible releases. The method uses only two pieces of paper. The first is a map of the offsite area showing the shape of the plume for the duration of the exercise. The second is a semilog graph containing curves that relate exposure rate and iodine concentration to downwind distance and time. Several techniques are used to maximize the information on the graph

  19. The Development of Laboratory Safety Questionnaire for Middle School Science Teachers

    Science.gov (United States)

    Akpullukcu, Simge; Cavas, Bulent

    2017-01-01

    The purpose of this paper is to develop a "valid and reliable laboratory safety questionnaire" which could be used to identify science teachers' understanding about laboratory safety issues during their science laboratory activities. The questionnaire was developed from a literature review and prior instruments developed on laboratory…

  20. Between and within laboratory reliability of mouse behaviour recorded in home-cage and open-field.

    Science.gov (United States)

    Robinson, Lianne; Spruijt, Berry; Riedel, Gernot

    2018-04-15

    Reproducibility of behavioural findings between laboratories is difficult due to behaviour being sensitive to environmental factors and interactions with genetics. The objective of this study was to investigate reproducibility of behavioural data between laboratories using the PhenoTyper home cage observation system and within laboratory reproducibility using different lighting regimes. The ambulatory activity of C57BL/6 and DBA/2 mice was tested in PhenoTypers in two laboratories under near identical housing and testing conditions (Exp. 1). Additionally activity and anxiety were also assessed in the open-field test. Furthermore, testing in either a normal or inverted light/dark cycle was used to determine effects of lighting regime in a within-laboratory comparison in Aberdeen (Exp. 2). Using the PhenoTyper similar circadian rhythms were observed across laboratories. Higher levels of baseline and novelty-induced activity were evident in Aberdeen compared to Utrecht although strain differences were consistent between laboratories. Open field activity was also similar across laboratories whereas strain differences in anxiety were different. Within laboratory analysis of different lighting regimes revealed that behaviour of the mice was sensitive to changes in lighting. Utilisation of a home cage observation system facilitates the reproducibility of activity but not anxiety-related behaviours across laboratories by eliminating environmental factors known to influence reproducibility in standard behavioural tests. Standardisation of housing/test conditions resulted in reproducibility of home cage and open field activity but not anxiety-related phenotypes across laboratories with some behaviours more sensitive to environmental factors. Environmental factors include lighting and time of day. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Validity and Reliability of the Cycleops Hammer Cycle Ergometer.

    Science.gov (United States)

    Lillo-Bevia, José R; Pallarés, Jesús G

    2017-11-28

    To validate the new drive indoor trainer Hammer designed by Cycleops®. Eleven cyclists performed 44 randomized and counterbalanced graded exercise tests (100-500W), at 70, 85 and 100 rev.min -1 cadences, in seated and standing positions, on 3 different Hammer units, while a scientific SRM system continuously recorded cadence and power output data. No significant differences were detected between the three Hammer devices and the SRM for any workload, cadence, or pedalling condition (P value between 1.00 and 0.350), except for some minor differences (P 0.03 and 0.04) found in the Hammer 1 at low workloads, and for Hammer 2 and 3 at high workloads, all in seated position. Strong ICCs were found between the power output values recorded by the Hammers and the SRM (≥0.996; P=0.001), independently from the cadence condition and seated position. Bland-Altman analysis revealed low Bias (-5.5-3.8) and low SD of Bias (2.5-5.3) for all testing conditions, except marginal values found for the Hammer 1 at high cadences and seated position (9.6±6.6). High absolute reliability values were detected for the 3 Hammers (150-500W; CVreliable device to drive and measure power output in cyclists, providing an alternative to larger and more expensive laboratory ergometers, and allowing cyclists to use their own bicycle.

  2. Changes in fatigue, multiplanar knee laxity, and landing biomechanics during intermittent exercise.

    Science.gov (United States)

    Shultz, Sandra J; Schmitz, Randy J; Cone, John R; Henson, Robert A; Montgomery, Melissa M; Pye, Michele L; Tritsch, Amanda J

    2015-05-01

    Knee laxity increases during exercise. However, no one, to our knowledge, has examined whether these increases contribute to higher-risk landing biomechanics during prolonged, fatiguing exercise. To examine associations between changes in fatigue (measured as sprint time [SPTIME]), multiplanar knee laxity (anterior-posterior [APLAX], varus-valgus [VVLAX] knee laxity, and internal-external rotation [IERLAX]) knee laxity and landing biomechanics during prolonged, intermittent exercise. Descriptive laboratory study. Laboratory and gymnasium. A total of 30 male (age = 20.3 ± 2.0 years, height = 1.79 ± 0.05 m, mass = 75.2 ± 7.2 kg) and 29 female (age = 20.5 ± 2.3 years, height = 1.67 ± 0.08 m, mass = 61.8 ± 9.0 kg) competitive athletes. A 90-minute intermittent exercise protocol (IEP) designed to simulate the physiologic and biomechanical demands of a soccer match. We measured SPTIME, APLAX, and landing biomechanics before and after warm-up, every 15 minutes during the IEP, and every 15 minutes for 1 hour after the IEP. We measured VVLAX and IERLAX before and after the warm-up, at 45 and 90 minutes during the IEP, and at 30 minutes after the IEP. We used hierarchical linear modeling to examine associations between exercise-related changes in SPTIME and knee laxity with exercise-related changes in landing biomechanics while controlling for initial (before warm-up) knee laxity. We found that SPTIME had a more global effect on landing biomechanics in women than in men, resulting in a more upright landing and a reduction in landing forces and out-of-plane motions about the knee. As APLAX increased with exercise, women increased their knee internal-rotation motion (P = .02), and men increased their hip-flexion motion and energy-absorption (P = .006) and knee-extensor loads (P = .04). As VVLAX and IERLAX increased, women went through greater knee-valgus motion and dorsiflexion and absorbed more energy at the knee (P ≤ .05), whereas men were positioned in greater hip

  3. Exercise reduces adipose tissue via cannabinoid receptor type 1 which is regulated by peroxisome proliferator-activated receptor-delta

    DEFF Research Database (Denmark)

    Yan, Zhen Cheng; Liu, Dao Yan; Zhang, Li Li

    2007-01-01

    Obesity is one major cardiovascular risk factor. We tested effects of endurance exercise on cannabinoid receptor type 1 (CB1) and peroxisome proliferator-activated receptor-delta (PPAR-delta)-dependent pathways in adipose tissue. Male Wistar rats were randomly assigned to standard laboratory chow...... or a high-fat diet without and with regular endurance exercise. Exercise in rats on high-fat diet significantly reduced visceral fat mass, blood pressure, and adipocyte size (each p...

  4. Ejection fraction response to exercise in patients with chest pain and normal coronary arteriograms

    International Nuclear Information System (INIS)

    Gibbons, R.L.; Lee, K.L.; Cobb, F.; Jones, R.H.

    1981-01-01

    In this study we describe the ejection fraction response to upright exercise using first-pass radionuclide angiocardiography in a group of 60 patients with chest pain, normal coronary ateriograms and normal resting ventricular function. A wide range of resting function (heart rate and ejection fraction) and exercise function (heart rate, ejection fraction, peak work load and estimated peak oxygen uptake) were measured. The ejection fraction response to exercise demonstrated wide variation, ranging from a decrease of 23% to an increase of 24%. Six of 22 clinical and radionuclide angiocardiographic variables (resting ejection fraction, peak work load, age, sex, body surface area and the change in end-diastolic volume index with exercise) were significant univariate predictors of the ejection fraction response to exercise. Multivariable analysis identified resting ejection fraction, the change in end-diastolic volume index with exercise and either sex or peak work load as variables that provided significant independent predictive information. These observations indicate that the ejection fraction response to exercise is a complex response that is influenced by multiple physiologic variables. The wide variation in this population suggests that the ejection fraction response to exercise is not a reliable test for the diagnosis of coronary artery disease because of its low specificity

  5. Industry and Academic Consortium for Computer Based Subsurface Geology Laboratory

    Science.gov (United States)

    Brown, A. L.; Nunn, J. A.; Sears, S. O.

    2008-12-01

    Twenty two licenses for Petrel Software acquired through a grant from Schlumberger are being used to redesign the laboratory portion of Subsurface Geology at Louisiana State University. The course redesign is a cooperative effort between LSU's Geology and Geophysics and Petroleum Engineering Departments and Schlumberger's Technical Training Division. In spring 2008, two laboratory sections were taught with 22 students in each section. The class contained geology majors, petroleum engineering majors, and geology graduate students. Limited enrollments and 3 hour labs make it possible to incorporate hands-on visualization, animation, manipulation of data and images, and access to geological data available online. 24/7 access to the laboratory and step by step instructions for Petrel exercises strongly promoted peer instruction and individual learning. Goals of the course redesign include: enhancing visualization of earth materials; strengthening student's ability to acquire, manage, and interpret multifaceted geological information; fostering critical thinking, the scientific method; improving student communication skills; providing cross training between geologists and engineers and increasing the quantity, quality, and diversity of students pursuing Earth Science and Petroleum Engineering careers. IT resources available in the laboratory provide students with sophisticated visualization tools, allowing them to switch between 2-D and 3-D reconstructions more seamlessly, and enabling them to manipulate larger integrated data-sets, thus permitting more time for critical thinking and hypothesis testing. IT resources also enable faculty and students to simultaneously work with the software to visually interrogate a 3D data set and immediately test hypothesis formulated in class. Preliminary evaluation of class results indicate that students found MS-Windows based Petrel easy to learn. By the end of the semester, students were able to not only map horizons and faults

  6. [Future roles of clinical laboratories and clinical laboratory technologists in university hospitals].

    Science.gov (United States)

    Yokota, Hiromitsu; Yatomi, Yutaka

    2013-08-01

    Clinical laboratories in university hospitals should be operated with a good balance of medical practice, education, research, and management. The role of a clinical laboratory is to promptly provide highly reliable laboratory data to satisfy the needs of clinicians involved in medical practice and health maintenance of patients. Improvement and maintenance of the quality of the laboratory staff and environment are essential to achieve this goal. In order to implement these requirements efficiently, an appropriate quality management system should be introduced and established, and evaluated objectively by a third party (e.g. by obtaining ISO 15189 certification). ISO 15189 is an international standard regarding the quality and competence of clinical laboratories, and specifies a review of the efficient operational system and technical requirements such as competence in implementing practical tests and calibration. This means the results of laboratory tests reported by accredited laboratories withstand any international evaluation, which is very important to assure the future importance of the existence and management of clinical laboratories as well as internationalization of medical practice. "Education" and "research" have important implications in addition to "medical practice" and "management", as the roles that clinical laboratories should play in university hospitals. University hospital laboratories should be operated by keeping these four factors in good balance. Why are "education" and "research" required in addition to "medical practice" services? If individual clinical laboratory technologists can provide an appropriate response to this question, the importance of the existence of clinical laboratories would be reinforced, without being compromised.

  7. Balance assessment during squatting exercise: A comparison between laboratory grade force plate and a commercial, low-cost device.

    Science.gov (United States)

    Mengarelli, Alessandro; Verdini, Federica; Cardarelli, Stefano; Di Nardo, Francesco; Burattini, Laura; Fioretti, Sandro

    2018-04-11

    Testing balance through squatting exercise is a central part of many rehabilitation programs and sports and plays also an important role in clinical evaluation of residual motor ability. The assessment of center of pressure (CoP) displacement and its parametrization is commonly used to describe and analyze squat movement and the laboratory-grade force plates (FP) are the gold standard for measuring balance performances from a dynamic view-point. However, the Nintendo Wii Balance Board (NWBB) has been recently proposed as an inexpensive and easily available device for measuring ground reaction force and CoP displacement in standing balance tasks. Thus, this study aimed to compare the NWBB-CoP data with those obtained from a laboratory FP during a dynamic motor task, such as the squat task. CoP data of forty-eight subjects were acquired simultaneously from a NWBB and a FP and the analyses were performed over the descending squatting phase. Outcomes showed a very high correlation (r) and limited root-mean-square differences between CoP trajectories in anterior-posterior (r > 0.99, 1.63 ± 1.27 mm) and medial-lateral (r > 0.98, 1.01 ± 0.75 mm) direction. Spatial parameters computed from CoP displacement and ground reaction force peak presented fixed biases between NWBB and FP. Errors showed a high consistency (standard deviation < 2.4% of the FP outcomes) and a random spread distribution around the mean difference. Mean velocity is the only parameter which exhibited a tendency towards proportional values. Findings of this study suggested the NWBB as a valid device for the assessment and parametrization of CoP displacement during squatting movement. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. The impact of laboratory quality assurance standards on laboratory operational performance

    Directory of Open Access Journals (Sweden)

    E Ratseou

    2014-01-01

    Full Text Available It has become a trend for companies to implement and be certified to various quality management systems so as to improve consistency, reliability, and quality of product delivery to customers. The most common quality management systems adopted are the ISO 9000 series of standards for manufacturing and services related organisations, with ISO 17025 and Good Laboratory Practices (GLP standards adopted specifically by laboratories as quality assurance initiatives. There are various reports on the impact of the ISO 9000 series on organisational performance but no studies or reports have been done on the performance of laboratory standards. Therefore this article reports on a study conducted to investigate the impact of ISO 17025 and GLP on the operational performance of both commercial and non-commercial laboratories. A qualitative research study was conducted to examine the impact standards on the aspects of health and safety, supplier selection and performance, human resources, customer satisfaction and profitability of the laboratory. The data collected suggest that there is no difference in laboratory operational performance with or without the standards. In other words it appears that the basic fundamental requirements inherent with laboratories are sufficient to perform both operationally and optimally. This leads to the view that standards are implemented as a customer requirement and not as an operational requirement.

  9. Experimental effects of acute exercise and music listening on cognitive creativity.

    Science.gov (United States)

    Frith, Emily; Loprinzi, Paul D

    2018-07-01

    The purpose of this study was to extend previous experimental work suggesting that both exercise and music-based interventions may influence creativity processes, by investigating the independent influences of exercise or music stimuli on verbal creative performances in the laboratory environment. 32 students at the University of Mississippi participated in this within-subject intervention, which included three laboratory visits per participant. Individuals participated in three 15-min, randomized experimental conditions: Treadmill walking, self-selected music, or a seated control period, and subsequently completed four creativity assessments during each visit (three tests of divergent thinking, and one test of convergent thinking), with the order of divergent thinking tasks counterbalanced. Creativity task performance was independently scored across four dependent parameters, which included fluency (i.e., total number of ideas), flexibility (i.e., total number of categories), originality (i.e., responses thought of by music on verbal creativity performance. The present study further highlights the critical need for improvement in the assessment and evaluation of laboratory-assessed cognitive creativity. Methodological strategies must be examined and refined for the meaningful and credible measurement and interpretation of experimental creativity. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Reliability and validity of ten consumer activity trackers

    NARCIS (Netherlands)

    Kooiman, Thea; Dontje, Manon L.; Sprenger, Siska; Krijnen, Wim; van der Schans, Cees; de Groot, Martijn

    2015-01-01

    Background: Activity trackers can potentially stimulate users to increase their physical activity behavior. The aim of this study was to examine the reliability and validity of ten consumer activity trackers for measuring step count in both laboratory and free-living conditions. Method: Healthy

  11. Computer-assisted upper extremity training using interactive biking exercise (iBikE) platform.

    Science.gov (United States)

    Jeong, In Cheol; Finkelstein, Joseph

    2012-01-01

    Upper extremity exercise training has been shown to improve clinical outcomes in different chronic health conditions. Arm-operated bicycles are frequently used to facilitate upper extremity training however effective use of these devices at patient homes is hampered by lack of remote connectivity with clinical rehabilitation team, inability to monitor exercise progress in real time using simple graphical representation, and absence of an alert system which would prevent exertion levels exceeding those approved by the clinical rehabilitation team. We developed an interactive biking exercise (iBikE) platform aimed at addressing these limitations. The platform uses a miniature wireless 3-axis accelerometer mounted on a patient wrist that transmits the cycling acceleration data to a laptop. The laptop screen presents an exercise dashboard to the patient in real time allowing easy graphical visualization of exercise progress and presentation of exercise parameters in relation to prescribed targets. The iBikE platform is programmed to alert the patient when exercise intensity exceeds the levels recommended by the patient care provider. The iBikE platform has been tested in 7 healthy volunteers (age range: 26-50 years) and shown to reliably reflect exercise progress and to generate alerts at pre-setup levels. Implementation of remote connectivity with patient rehabilitation team is warranted for future extension and evaluation efforts.

  12. Defense Civil Support: DOD Needs to Identify National Guards Cyber Capabilities and Address Challenges in Its Exercises

    Science.gov (United States)

    2016-09-01

    participated in exercises to support civil authorities in a cyber incident or to test the responses to simulated attacks on cyber infrastructure owned by...authorities or to test the response to simulated attacks on cyber infrastructure owned by civil authorities. Of these 9 exercises, DOD conducted 7...and a response to simulated cyber attacks on electric grid networks. According to a North American Electric Reliability Corporation official, DOD

  13. Corrected Launch Speed for a Projectile Motion Laboratory

    Science.gov (United States)

    Sanders, Justin M.; Boleman, Michael W.

    2013-01-01

    At our university, students in introductory physics classes perform a laboratory exercise to measure the range of a projectile fired at an assigned angle. A set of photogates is used to determine the initial velocity of the projectile (the launch velocity). We noticed a systematic deviation between the experimentally measured range and the range…

  14. Can exercise mimetics substitute for exercise?

    DEFF Research Database (Denmark)

    Richter, Erik; Kiens, Bente; Wojtaszewski, Jørgen

    2008-01-01

    Exercise leads to changes in muscle phenotype with important implications for exercise performance and health. A recent paper in Cell by Narkar et al. (2008) shows that many of the adaptations in muscle phenotype elicited by exercise can be mimicked by genetic manipulation and drug treatment...

  15. The development and psychometric evaluation of a self-efficacy scale for practicing pelvic floor exercises

    Directory of Open Access Journals (Sweden)

    Cinara Sacomori

    2013-08-01

    Full Text Available BACKGROUND: Self-efficacy has been shown to be a predictor of many health-related behaviors, including the practice of pelvic floor exercises with a focus on prevention or cure. OBJECTIVES: To describe the process of construction and the psychometric properties of the scale of self-efficacy for the practice of pelvic floor exercises (EAPEAP. METHOD: A cross-sectional study of validation was carried out with 81 from community and 96 postpartum women, 54.8% of them complained of urinary leakage. An exploratory factor analysis and internal consistency analysis was performed. To check predictive capacity, we analyzed the adherence at 3 months post - intervention and compared the scores of self-efficacy between adherent and non-adherent women. Reliability was analyzed by split half procedure. RESULTS: The instrument showed α=0.923, and revealed three factors: performance expectation considering the action, performance expectation considering the preparation for action and outcome expectations. These factors accounted for 65.32% of the total variance. The instrument was able to differentiate between women who adhere and have not adhered to the exercises (U=352, p=0.013 and there was strong correlation between the two halves of the instrument (rho=0.889, p<0.001. CONCLUSION: The scale is a valid and reliable tool to measure self-efficacy to practice pelvic floor exercises.

  16. Exercise identity as a risk factor for exercise dependence.

    Science.gov (United States)

    Murray, Aja L; McKenzie, Karen; Newman, Emily; Brown, Erin

    2013-05-01

    The aim of the study was to explore the relationship between exercise identity and exercise dependence. We hypothesized that stronger exercise identities would be associated with greater odds of experiencing exercise dependence symptoms. Logistic regression was used to assess the extent of association between exercise identity and the risk of experiencing exercise dependence symptoms. Participants (101) were recruited online via sports clubs and social networking sites and were asked to complete online measures of exercise identity and exercise dependence. The overall model fit was a significant improvement on the baseline model, but only the exercise beliefs factor was significantly associated with the odds of dependence symptoms, with higher scores on the belief scale predicting greater odds of experiencing dependence symptoms. Exercise role identity, in contrast, was not significantly associated with odds of experiencing dependence symptoms. Per cent correct classification was 55.9% for asymptomatic and 88.2% for symptomatic individuals and the overall per cent correct classification was 77.5%. The relation between identity and dependence could represent both a fruitful research avenue and a potential therapeutic target for those experiencing dependence symptoms; although our findings only showed a relationship between one of the two factors of the exercise identity measure and dependence. Longitudinal research is required to examine the relationship between identity and dependence in the context of other variables to better understand why some individuals become exercise dependent whereas others do not. What is already known on this subject? Exercise identity has been identified as an important determinant of exercise behaviour and studies within the exercise identity framework have proven elucidative with respect to the psychological processes that may underpin commitment to exercise. It has separately been established that some individuals may become

  17. Effect of exercise intensity on exercise and post exercise energy ...

    African Journals Online (AJOL)

    The aim of this study was to determine if exercise and post exercise energy expenditure are affected by the intensity of exercise during a set distance of 4km walking and/or jogging. Subjects for this study were 12 moderately obese females with mean fat percentage of 31.7±6.3% and mean age of 38.2±4.6 years. For the low ...

  18. Catsius Clay Project. Calculation and Testing of Behaviour of Unsaturated Clay as Barrier in Radioactive Waste Repositories. Stage 2: Validation Exercises at Laboratory scale

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, E E; Alcoverro, J

    1999-07-01

    Stage 2 of CATSIUS CLAY Project: Validation Exercises at Laboratory Scale includes two Benchmarks, Benchmark 2.1: Oedometer Suction Controlled Tests on Samples of compacted Boom Clay and Benchmark 2.2: Small Scale Weltting-Heating Test on Compacted Bentonite. BM 2.1 had two parts: BM 2.1A (volumetric deformation upon wetting-drying cycles) and BM 2.1 B (swelling pressure test). In BM 2.1A, participants were asked to model the results of a series of five tests on samples of compacted Boom clay. In BM 2.1B, a swelling pressure test in which suction, vertical and horizontal stresses were monitored, was proposed as a blind exercise. Participants were asked to use, without further changes, the models calibrated in BM 2.1A. This exercise provides an evaluation of the capabilities of current mechanical constitutive models for unsaturated clay behaviour. It was found that, even if a calibration exercise on the basis of known experimental data is satisfactory, blind predictions of tests involving different paths may prove difficult. The test set up for BM 2.2 consisted of a stainless stell cell filled with highly expansive compacted bentonite (S2 clay from Almeria, Spain). The clay was subjected to a simultaneous central heating and a progressive water inflow through the botton plate. Temperature at various locations within the sample and the boundary radial stress were monitored throughout the test. Water content distribution was also measured at the end of the experiment. Predictions for this benchmark required the solution of field equations for flow, temperature distribution and mechanical analysis. Model parameters were derived from the extensive set of available experiments on this clay. Comparison between model predictions and measurements revealed the significance of water transport in vapour phase, the difficulties to predict boundary stresses and the general good agreement between measured and calculated temperatures. The report provides a detailed accojnt of the

  19. Catsius Clay Project. Calculation and Testing of Behaviour of Unsaturated Clay as Barrier in Radioactive Waste Repositories. Stage 2: Validation Exercises at Laboratory scale

    International Nuclear Information System (INIS)

    Alonso, E. E.; Alcoverro, J.

    1999-01-01

    Stage 2 of CATSIUS CLAY Project: Validation Exercises at Laboratory Scale includes two Benchmarks, Benchmark 2.1: Oedometer Suction Controlled Tests on Samples of compacted Boom Clay and Benchmark 2.2: Small Scale Weltting-Heating Test on Compacted Bentonite. BM 2.1 had two parts: BM 2.1A (volumetric deformation upon wetting-drying cycles) and BM 2.1 B (swelling pressure test). In BM 2.1A, participants were asked to model the results of a series of five tests on samples of compacted Boom clay. In BM 2.1B, a swelling pressure test in which suction, vertical and horizontal stresses were monitored, was proposed as a blind exercise. Participants were asked to use, without further changes, the models calibrated in BM 2.1A. This exercise provides an evaluation of the capabilities of current mechanical constitutive models for unsaturated clay behaviour. It was found that, even if a calibration exercise on the basis of known experimental data is satisfactory, blind predictions of tests involving different paths may prove difficult. The test set up for BM 2.2 consisted of a stainless stell cell filled with highly expansive compacted bentonite (S2 clay from Almeria, Spain). The clay was subjected to a simultaneous central heating and a progressive water inflow through the botton plate. Temperature at various locations within the sample and the boundary radial stress were monitored throughout the test. Water content distribution was also measured at the end of the experiment. Predictions for this benchmark required the solution of field equations for flow, temperature distribution and mechanical analysis. Model parameters were derived from the extensive set of available experiments on this clay. Comparison between model predictions and measurements revealed the significance of water transport in vapour phase, the difficulties to predict boundary stresses and the general good agreement between measured and calculated temperatures. The report provides a detailed accojnt of the

  20. Reliability and norms for the 10-item self-motivation inventory: The TIGER Study

    Science.gov (United States)

    The Self-Motivation Inventory (SMI) has been shown to be a predictor of exercise dropout. The original SMI of 40 items has been shortened to 10 items and the psychometric qualities of the 10-item SMI are not known. To estimate the reliability of a 10-item SMI and develop norms for an ethnically dive...