WorldWideScience

Sample records for reliable dispenser cathodes

  1. Barium-Dispenser Thermionic Cathode

    Science.gov (United States)

    Wintucky, Edwin G.; Green, M.; Feinleib, M.

    1989-01-01

    Improved reservoir cathode serves as intense source of electrons required for high-frequency and often high-output-power, linear-beam tubes, for which long operating lifetime important consideration. High emission-current densities obtained through use of emitting surface of relatively-low effective work function and narrow work-function distribution, consisting of coat of W/Os deposited by sputtering. Lower operating temperatures and enhanced electron emission consequently possible.

  2. Plasma processes inside dispenser hollow cathodes

    International Nuclear Information System (INIS)

    Mikellides, Ioannis G.; Katz, Ira; Goebel, Dan M.; Polk, James E.; Jameson, Kristina K.

    2006-01-01

    A two-dimensional fluid model of the plasma and neutral gas inside dispenser orificed hollow cathodes has been developed to quantify plasma processes that ultimately determine the life of the porous emitters inserted in these devices. The model self-consistently accounts for electron emission from the insert as well as for electron and ion flux losses from the plasma. Two cathodes, which are distinctively different in size and operating conditions, have been simulated numerically. It is found that the larger cathode, with outer tube diameter of 1.5 cm and orifice diameter of 0.3 cm, establishes an effective emission zone that spans approximately the full length of the emitter when operated at a discharge current of 25 A and a flow rate of 5.5 sccm. The net heating of the emitter is caused by ions that are produced by ionization of the neutral gas inside the tube and are then accelerated by the sheath along the emitter. The smaller cathode, with an outer diameter of 0.635 cm and an orifice diameter of 0.1 cm, does not exhibit the same operational characteristics. At a flow rate of 4.25 sccm and discharge current of 12 A, the smaller cathode requires 4.5 times the current density near the orifice and operates with more than 6 times the neutral particle density compared to the large cathode. As a result, the plasma particle density is almost one order of magnitude higher compared to the large cathode. The plasma density in this small cathode is high enough such that the Debye length is sufficiently small to allow 'sheath funneling' into the pores of the emitter. By accessing areas deeper into the insert material, it is postulated that the overall emission of electrons is significantly enhanced. The maximum emission current density is found to be about 1 A/mm 2 in the small cathode, which is about one order of magnitude higher than attained in the large cathode. The effective emission zone in the small cathode extends to about 15% of the emitter length only, and the

  3. Large area dispenser cathode applied to high current linac

    International Nuclear Information System (INIS)

    Yang Anmin; China Academy of Engineering Physics, Mianyang; Wu Dengxue; Liu Chenjun; Xia Liansheng; Wang Wendou; Zhang Kaizhi

    2005-01-01

    The paper introduced a dispenser cathode (411 M) which was 55 mm in diameter. A 200 kV long pulsed power generator with 2 μs flattop based on Marx-PEN and system with heat and voltage insulation were built. A 52 A space charge limited current was gained, when the temperature was 1165 degree C and the filament current was 18 A on the cathode and the voltage of the pulse was 75 kV at the cathode test stand. Experimental results show that the current values are consistent with the numerical simulation. The experiment reveals that the deflated gas will influence the cathode emission ability. (authors)

  4. The tungsten powder study of the dispenser cathode

    International Nuclear Information System (INIS)

    Bao Jixiu; Wan Baofei

    2006-01-01

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes has been investigated for the different grain morphologies. It is shown that a fully cleaning step of the tungsten powder is so necessary that the tungsten powder will be reduction of oxide in hydrogen atmosphere above 700 deg. C. The porosity of the tungsten matrix distributes more even and the closed pore is fewer, the average granule size of the tungsten powder distributes more convergent. The porosity of the tungsten matrix and the evaporation of the activator are bigger and the pulse of the cathode is smaller when the granularity is bigger by the analysis of the electronic microscope and diode experiment

  5. The tungsten powder study of the dispenser cathode

    Science.gov (United States)

    Bao, Ji-xiu; Wan, Bao-fei

    2006-06-01

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes has been investigated for the different grain morphologies. It is shown that a fully cleaning step of the tungsten powder is so necessary that the tungsten powder will be reduction of oxide in hydrogen atmosphere above 700 °C. The porosity of the tungsten matrix distributes more even and the closed pore is fewer, the average granule size of the tungsten powder distributes more convergent. The porosity of the tungsten matrix and the evaporation of the activator are bigger and the pulse of the cathode is smaller when the granularity is bigger by the analysis of the electronic microscope and diode experiment.

  6. Back bombardment for dispenser and lanthanum hexaboride cathodes

    Directory of Open Access Journals (Sweden)

    Mahmoud Bakr

    2011-06-01

    Full Text Available The back bombardment (BB effect limits wide usage of thermionic rf guns. The BB effect induces not only ramping-up of a cathode’s temperature and beam current, but also degradation of cavity voltage and beam energy during a macropulse. This paper presents a comparison of the BB effect for the case of dispenser tungsten-base (DC and lanthanum hexaboride (LaB_{6} thermionic rf gun cathodes. For each, particle simulation codes are used to simulate the BB effect and electron beam dynamics in a thermionic rf gun cathode. A semiempirical equation is also used to investigate the stopping range and deposited heat power of BB electrons in the cathode material. A numerical simulation method is used to calculate the change of the cathode temperature and current density during a single macropulse. This is done by solving two differential equations for the rf gun cavity equivalent circuit and one-dimensional thermal diffusion equation. High electron emission and small beam size are required for generation of a high-brightness electron beam, and so in this work the emission properties of the cathode are taken into account. Simulations of the BB effect show that, for a pulse of 6  μs duration, the DC cathode experiences a large change in the temperature compared with LaB_{6}, and a change in current density 6 times higher. Validation of the simulation results is performed using experimental data for beam current beyond the gun exit. The experimental data is well reproduced using the simulation method.

  7. Development of alloy-film coated dispenser cathode for terahertz vacuum electron devices application

    International Nuclear Information System (INIS)

    Barik, R.K.; Bera, A.; Raju, R.S.; Tanwar, A.K.; Baek, I.K.; Min, S.H.; Kwon, O.J.; Sattorov, M.A.; Lee, K.W.; Park, G.-S.

    2013-01-01

    High power terahertz vacuum electron devices demand high current density and uniform emission dispenser cathode. It was found that the coating of noble metals e.g., Os, Ir, and Re on the surface of tungsten dispenser cathodes enhances the emission capabilities and uniformity. Hence metal coated cathode might be the best candidate for terahertz devices applications. In this study, ternary-alloy-film cathode (2Os:2Re:1 W) and Os coated cathode have been developed and the results are presented. The cathodes made out of this alloy coating showed 1.5 times higher emission and 0.02 eV emission uniformity as compared to those of simply Os coated cathodes which can be used in terahertz devices application.

  8. Development of alloy-film coated dispenser cathode for terahertz vacuum electron devices application

    Energy Technology Data Exchange (ETDEWEB)

    Barik, R. K.; Bera, A. [School of Electrical Engineering and Computer Science, Seoul National University, Seoul (Korea, Republic of); Raju, R. S. [Central Electronics Engineering Research Institute (CEERI), Rajasthan (India); Tanwar, A. K.; Baek, I. K.; Min, S. H.; Kwon, O. J.; Sattorov, M. A. [Department of Physics and Astronomy, Center for THz-Bio Application Systems, and Seoul-Teracom Inc., Seoul National University, Seoul (Korea, Republic of); Lee, K. W. [LIG Nex1, Seoul (Korea, Republic of); Park, G.-S., E-mail: gunsik@snu.ac.kr [School of Electrical Engineering and Computer Science, Seoul National University, Seoul (Korea, Republic of); Department of Physics and Astronomy, Center for THz-Bio Application Systems, and Seoul-Teracom Inc., Seoul National University, Seoul (Korea, Republic of); Advanced Institute of Convergence Technology, Suwon-si, Gyeonggi-do (Korea, Republic of)

    2013-07-01

    High power terahertz vacuum electron devices demand high current density and uniform emission dispenser cathode. It was found that the coating of noble metals e.g., Os, Ir, and Re on the surface of tungsten dispenser cathodes enhances the emission capabilities and uniformity. Hence metal coated cathode might be the best candidate for terahertz devices applications. In this study, ternary-alloy-film cathode (2Os:2Re:1 W) and Os coated cathode have been developed and the results are presented. The cathodes made out of this alloy coating showed 1.5 times higher emission and 0.02 eV emission uniformity as compared to those of simply Os coated cathodes which can be used in terahertz devices application.

  9. Correlation of emission capability and longevity of dispenser cathodes with characteristics of tungsten powders

    Science.gov (United States)

    Melnikova, Irina P.; Vorozheikin, Victor G.; Usanov, Dmitry A.

    2003-06-01

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes are investigated for three different grain morphologies. Best results of tungsten cathode life were found for isoaxis polyhedron morphology in combination with certain powder and matrix parameters.

  10. Correlation of emission capability and longevity of dispenser cathodes with characteristics of tungsten powders

    International Nuclear Information System (INIS)

    Melnikova, Irina P.; Vorozheikin, Victor G.; Usanov, Dmitry A.

    2003-01-01

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes are investigated for three different grain morphologies. Best results of tungsten cathode life were found for isoaxis polyhedron morphology in combination with certain powder and matrix parameters

  11. Correlation of emission capability and longevity of dispenser cathodes with characteristics of tungsten powders

    Energy Technology Data Exchange (ETDEWEB)

    Melnikova, Irina P.; Vorozheikin, Victor G.; Usanov, Dmitry A

    2003-06-15

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes are investigated for three different grain morphologies. Best results of tungsten cathode life were found for isoaxis polyhedron morphology in combination with certain powder and matrix parameters.

  12. Using Multispectral Imaging to Measure Temperature Profiles and Emissivity of Large Thermionic Dispenser, Cathodes

    International Nuclear Information System (INIS)

    Simmons, D.F.; Fortgang, C.M.; Holtkamp, D.B.

    2001-01-01

    Thermionic dispenser cathodes are widely used in modern high-power microwave tubes. Use of these cathodes has led to significant improvement in performance. In recent years these cathodes have been used in electron linear accelerators (LINACs), particularly in induction LINACs, such as the Experimental Test Accelerator at Lawrence Livermore National Laboratory and the Relativistic Test Accelerator at Lawrence Berkeley National Laboratory. For induction LINACs, the thermionic dispenser cathode provides greater reproducibility, longer pulse lengths, and lower emittance beams than does a field emission cathode. Los Alamos National Laboratory is fabricating a dual-axis X-ray radiography machine called dual-axis radiograph hydrodynamic test (DARHT). The second axis of DARHT consists of a 2-kA, 20-MeV induction LINAC that uses a 3.2-MeV electron gun with a tungsten thermionic-dispenser cathode. Typically the DARHT cathode current density is 10 A/cm 2 at 1050 C. Under these conditions current density is space-charge limited, which is desirable since current density is independent of temperature. At lower temperature (the temperature-limited regime) there are variations in the local current density due to a nonuniform temperature profile. To obtain the desired uniform current density associated with space-charge limited operation, the coolest area on the cathode must be at a sufficiently high temperature so that the emission is space-charge limited. Consequently, the rest of the cathode is emitting at the same space-charge-limited current density but is at a higher temperature than necessary. Because cathode lifetime is such a strong function of cathode temperature, there is a severe penalty for nonuniformity in the cathode temperature. For example, a temperature increase of 50 C means cathode lifetime will decrease by a factor of at least four. Therefore, we are motivated to measure the temperature profiles of our large-area cathodes

  13. Emission characteristics of dispenser cathodes with a fine-grained tungsten top layer

    Science.gov (United States)

    Kimura, S.; Higuchi, T.; Ouchi, Y.; Uda, E.; Nakamura, O.; Sudo, T.; Koyama, K.

    1997-02-01

    In order to improve the emission stability of the Ir-coated dispenser cathode under ion bombardment, a fine-grained tungsten top layer was applied on the substrate porous tungsten plug before Ir coating. The emission characteristics were studied after being assembled in a CRT gun. Cathode current was measured under pulse operation in a range of 0.1-9% duty. Remarkable anti-ion bombardment characteristics were observed over the range of 1-6% duty. The improved cathode showed 1.5 times higher emission current than that of a conventional Ir-coated dispenser cathode at 4% duty. AES analysis showed that the recovering rates of surface Ba and O atoms after ion bombardment were 2.5 times higher. From these results it is confirmed that the Ir coated cathode with a fine-grained tungsten top layer is provided with a good tolerance against the ion bombardment.

  14. Studies on the pressed yttrium oxide-tungsten matrix as a possible dispenser cathode material

    International Nuclear Information System (INIS)

    Yang, Fan; Wang, Jinshu; Liu, Wei; Liu, Xiang; Zhou, Meiling

    2015-01-01

    Yttrium oxide was chosen as the secondary emission substance based on calculation results through first principle theory method. A new kind of pressed yttrium oxide-tungsten matrix dispenser cathodes are prepared by a sol–gel method combined with high temperature sintering in dry hydrogen atmosphere. The results show that the growth of the grains is hampered by the pinning effect of Y 2 O 3 distributing uniformly between the tungsten particles, resulting in the formation of small grain size. It is found that Y 2 O 3 improves the secondary electron emission property, i.e., the secondary emission yield increases with the increase of Y 2 O 3 content in the samples. The maximum secondary emission yield δ max of the cathode with 15% amount of Y 2 O 3 can reach 2.92. Furthermore, the cathode shows a certain thermionic emission performance. The zero field emission current density J 0 of 4.18A/cm 2 has reached at 1050 °C b for this kind of cathode after being activated at 1200 °C b , which are much higher than that of rare earth oxide doped molybdenum (REO-Mo) cathode reported in the previous work. - Highlights: • Yttrium oxide was chosen as the secondary emission substance based on first principle calculation result. • A new kind of cathode has been successfully obtained. • Pressed yttrium oxide-tungsten matrix dispenser cathode exhibits good emission properties. • The improvement of the cathode emission can be well explained by the surface analysis results presented in this work

  15. Studies on the pressed yttrium oxide-tungsten matrix as a possible dispenser cathode material

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Fan; Wang, Jinshu, E-mail: wangjsh@bjut.edu.cn; Liu, Wei; Liu, Xiang; Zhou, Meiling

    2015-01-15

    Yttrium oxide was chosen as the secondary emission substance based on calculation results through first principle theory method. A new kind of pressed yttrium oxide-tungsten matrix dispenser cathodes are prepared by a sol–gel method combined with high temperature sintering in dry hydrogen atmosphere. The results show that the growth of the grains is hampered by the pinning effect of Y{sub 2}O{sub 3} distributing uniformly between the tungsten particles, resulting in the formation of small grain size. It is found that Y{sub 2}O{sub 3} improves the secondary electron emission property, i.e., the secondary emission yield increases with the increase of Y{sub 2}O{sub 3} content in the samples. The maximum secondary emission yield δ{sub max} of the cathode with 15% amount of Y{sub 2}O{sub 3} can reach 2.92. Furthermore, the cathode shows a certain thermionic emission performance. The zero field emission current density J{sub 0} of 4.18A/cm{sup 2} has reached at 1050 °C{sub b} for this kind of cathode after being activated at 1200 °C{sub b}, which are much higher than that of rare earth oxide doped molybdenum (REO-Mo) cathode reported in the previous work. - Highlights: • Yttrium oxide was chosen as the secondary emission substance based on first principle calculation result. • A new kind of cathode has been successfully obtained. • Pressed yttrium oxide-tungsten matrix dispenser cathode exhibits good emission properties. • The improvement of the cathode emission can be well explained by the surface analysis results presented in this work.

  16. Investigation of Influence of Surface Nanoparticle on Emission Properties of Scandia-Doped Dispenser Cathodes

    Science.gov (United States)

    Zhang, Xizhu; Wang, Jinshu; Wang, Yiman; Liu, Wei; Zhou, Meiling; Gao, Zhiyuan

    2013-06-01

    The microstructure of a fully activated scandia doped dispenser (SDD) cathode has been studied by scanning electron microscope (SEM). The observation results display that nanoparticles appear at the growth steps and the surface of tungsten grains of the fully activated SDD cathode. To study the influence of the nanoparticles on the emission, the local electric field strengths around the nanoparticles have been calculated by Maxwell 2D code and Comsol. The calculation results show that the local electric field strengths are enhanced by 1.1 to 3.8 times to average value based on different model conditions. The highest field strength is about 1.54 × 105 V/cm at an average field strength of 40 KV/cm, which is related to a space-charge limited (SCL) current density of 100 A/cm2 in the experimental configuration. This implies the field strength is not high enough to cause field emission.

  17. Multi-pulsed intense electron beam emission from velvet, carbon fibers, carbon nano-tubes and dispenser cathodes

    International Nuclear Information System (INIS)

    Xia Liansheng; Yang Anmin; Chen Yi; Zhang Huang; Liu Xingguang; Li Jin; Jiang Xiaoguo; Zhang Kaizhi; Shi Jinshui; Deng Jianjun; Zhang Linwen

    2010-01-01

    The experimental results of studies of four kinds of cathode emitting intense electron beams are demonstrated under multi-pulsed mode based on an experimental setup including two multi-pulse high voltage sources. The tested cathodes include velvet, carbon fibers, carbon nano-tubes (CNTs) and dispenser cathodes. The results indicate that all four are able to emit multi-pulsed beams. For velvet, carbon fiber and CNTs, the electron induced cathode plasma emission may be the main process and this means that there are differences in beam parameters from pulse to pulse. For dispenser cathodes tested in the experiment, although there is a little difference from pulse to pulse for some reason, thermal-electric field emission may be the main process. (authors)

  18. A study of scandia and rhenium doped tungsten matrix dispenser cathode

    Science.gov (United States)

    Wang, Jinshu; Li, Lili; Liu, Wei; Wang, Yanchun; Zhao, Lei; Zhou, Meiling

    2007-10-01

    Scandia and rhenium doped tungsten powders were prepared by solid-liquid doping combined with two-step reduction method. The experimental results show that scandia was distributed evenly on the surface of tungsten particles. The addition of scandia and rhenium could decrease the particle size of doped tungsten, for example, the tungsten powders doped with Sc 2O 3 and Re had the average size of about 50 nm in diameter. By using this kind of powder, scandia and rhenium doped tungsten matrix with the sub-micrometer sized tungsten grains was obtained. This kind of matrix exhibited good anti-bombardment insensitivity at high temperature. The emission property result showed that high space charge limited current densities of more than 60 A/cm 2 at 900 °C could be obtained for this cathode. A Ba-Sc-O multilayer about 100 nm in thickness formed at the surface of cathode after activation led to the high emission property.

  19. Emission property of scandia and Re doped tungsten matrix dispenser cathode

    International Nuclear Information System (INIS)

    Wang Jinshu; Wang Yanchun; Liu Wei; Li Lili; Wang Yiman; Zhou Meiling

    2008-01-01

    Scandia and rhenium doped tungsten powders have been prepared by solid-liquid doping combined with two-step reduction method. The experimental results show that scandia distributes evenly in the doped tungsten powder. Moreover, the addition of scandia and rhenium could decrease the particle size of tungsten. By using this kind of powder, scandia and rhenium doped tungsten matrix with sub-micrometer sized tungsten grains and a uniform distribution of Sc 2 O 3 together with high pore density has been obtained. The emission property result shows that high space charge limited current density of more than 30 A/cm 2 at 850 deg. C has been obtained for this cathode. This excellent emission capability results from an active layer uniformly covering the sub-micron structure framework of the cathodes

  20. Tiger Teams Technical Assistance: Reliable, Universal Open Architecture for Card Access to Dispense Alternative Fuels

    Energy Technology Data Exchange (ETDEWEB)

    2002-03-01

    Report discusses the dilemma of incorporating consistent, convenient, universal card access (or ''pay-at-the-pump'') systems into alternative fueling stations across the country. The state of California continues to be in the forefront of implementing alternative fuels for transportation applications. Aggressive efforts to deploy alternative fuel vehicles (AFVs) in California have highlighted the need to provide adequate fueling stations and develop appropriate, user-friendly means to purchase fuel at the pump. Since these fuels are not typically provided by petroleum companies at conventional fueling stations, and acceptance of cash is often not an option, a payment method must be developed that is consistent with the way individual AFV operators are accustomed to purchasing automotive fuels--with a credit card. At the same time, large fleets like the California Department of General Services must be able to use a single fuel card that offers comprehensive fleet management services. The Gas Technology Institute's Infrastructure Working Group (IWG) and its stakeholders have identified the lack of a common card reader system as a hurdle to wider deployment of AFVs in California and the United States. In conjunction with the U.S. Department of Energy's (DOE) National Clean Cities Program, the IWG has outlined a multi-phased strategy to systematically address the barriers to develop a more ''open'' architecture that's similar to the way gasoline and diesel are currently dispensed. Under the auspices of the IWG, survey results were gathered (circa 1999) from certain fuel providers, as a means to more carefully study card reader issues and their potential solutions. Pilot programs featuring card reader systems capable of accepting wider payment options have been attempted in several regions of the United States with mixed success. In early 2001, DOE joined the National Renewable Energy Laboratory (NREL), the

  1. Towards more reliable automated multi-dose dispensing: retrospective follow-up study on medication dose errors and product defects.

    Science.gov (United States)

    Palttala, Iida; Heinämäki, Jyrki; Honkanen, Outi; Suominen, Risto; Antikainen, Osmo; Hirvonen, Jouni; Yliruusi, Jouko

    2013-03-01

    To date, little is known on applicability of different types of pharmaceutical dosage forms in an automated high-speed multi-dose dispensing process. The purpose of the present study was to identify and further investigate various process-induced and/or product-related limitations associated with multi-dose dispensing process. The rates of product defects and dose dispensing errors in automated multi-dose dispensing were retrospectively investigated during a 6-months follow-up period. The study was based on the analysis of process data of totally nine automated high-speed multi-dose dispensing systems. Special attention was paid to the dependence of multi-dose dispensing errors/product defects and pharmaceutical tablet properties (such as shape, dimensions, weight, scored lines, coatings, etc.) to profile the most suitable forms of tablets for automated dose dispensing systems. The relationship between the risk of errors in dose dispensing and tablet characteristics were visualized by creating a principal component analysis (PCA) model for the outcome of dispensed tablets. The two most common process-induced failures identified in the multi-dose dispensing are predisposal of tablet defects and unexpected product transitions in the medication cassette (dose dispensing error). The tablet defects are product-dependent failures, while the tablet transitions are dependent on automated multi-dose dispensing systems used. The occurrence of tablet defects is approximately twice as common as tablet transitions. Optimal tablet preparation for the high-speed multi-dose dispensing would be a round-shaped, relatively small/middle-sized, film-coated tablet without any scored line. Commercial tablet products can be profiled and classified based on their suitability to a high-speed multi-dose dispensing process.

  2. Reliability centred maintenance of the cathodic protection system of the Bolivia-Brazil gas pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, Jorge Fernando Pereira [Transportadora Brasileira Gasoduto, TBG, Bolivia-Brasil S.A (Brazil)

    2004-07-01

    This paper presents the results of the Reliability-Centred Maintenance study performed on the Cathodic Protection System of the Bolivia -Brazil Gas Pipeline. The Cathodic Protection installation for the north spread (from Corumba to Guararema, 1413 km) was commissioned in March 1999 and for the south spread (from Campinas to Porto Alegre, 1180 km) one year after. The protection against corrosion of the buried external surface of our gas pipeline is provided, primarily, by an high-efficient external coating, complemented by a impressed current cathodic protection system consisting of: - Forty-one rectifiers and respective anodes ground beds; - One solar panel and respective anodes ground beds; - Fifty-nine insulating joints and respective protective devices; - Nine hundred and ninety pipe-to-soil test stations; - Thirty-six pipe-to-soil remote monitoring devices; - Forty-one electrical power feeder network to the rectifiers. The rectifiers/anodes ground beds are installed at each 50 km approximately, including the solar panel, and the pipe-to-soil test stations at each 2.5 km, under different environment conditions. The insulating joints and theirs protective devices are installed inside stations (launch and receive scrapers, compression and metering) and city-gates, as well, the pipe-to-soil remote monitoring devices. The cathodic protection system and electrical power feeder network are inspected and maintained by a TBG third part Contractor.

  3. Depression cathode structure for cathode ray tubes having surface smoothness and method for producing same

    International Nuclear Information System (INIS)

    Rychlewski, T.V.

    1984-01-01

    Depression cathode structures for cathode ray tubes are produced by dispensing liquid cathode material into the depression of a metallic supporting substrate, removing excess cathode material by passing a doctor blade across the substrate surface and over the depression, and drying the cathode layer to a substantially immobile state. The cathode layer may optionally be further shaped prior to substantially complete drying thereof

  4. Establishing reliable good initial quantum efficiency and in-situ laser cleaning for the copper cathodes in the RF gun

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, F., E-mail: zhoufeng@slac.stanford.edu; Sheppard, J.C.; Vecchione, T.; Jongewaard, E.; Brachmann, A.; Corbett, J.; Gilevich, S.; Weathersby, S.

    2015-05-21

    Establishing good initial quantum efficiency (QE) and reliable in-situ cleaning for copper cathode in the RF gun is of critical importance for the RF gun operations. Recent studies on the SLAC RF gun test bed indicated that the pre-cleaning (plasma cleaning) in the test chamber followed by copper cathode exposure to air for cathode change leads to a very low initial QE in the RF gun, and also demonstrated that without the pre-cleaning good initial QE >4×10{sup −5} can be routinely achieved in the RF gun with the cathodes of QE <1×10{sup −7} measured in the test chamber. QE can decay over the time in the RF gun. The in-situ laser cleaning technique for copper cathodes in the RF gun is established and refined in comparison to previous cleaning at the linac coherent light source, resulting in an improved QE and emittance evolutions. The physics of the laser cleaning process is discussed. It is believed that the reflectivity change is one of the major factors for the QE boost with the laser cleaning.

  5. Methods for dispensing mercury into devices

    Science.gov (United States)

    Grossman, Mark W.; George, William A.

    1987-04-28

    A process for dispensing mercury into devices which requires mercury. Mercury is first electrolytically separated from either HgO or Hg.sub.2 Cl.sub.2 and plated onto a cathode wire. The cathode wire is then placed into a device requiring mercury.

  6. Advanced Medication Dispenser

    Directory of Open Access Journals (Sweden)

    A.I. Alexan

    2013-12-01

    Full Text Available Medication dispensing is an important activity that can have major implications if done improperly. Dispensing must be done in the correct time interval, at the correct user, with the correct drug and dose. We propose a smart medication dispenser that can satisfy these needs and provide a mechanism for supervision. In order to ensure that the dispensing process is error free, the concept of a new smart medication container is used. A smart medication container is “smart” as it holds the medication dispensing parameters for the drugs it contains: dispensing time and date and name. Based on this information, the actual dispensing is done.

  7. Perceptions of Dispensers Regarding Dispensing Practices in ...

    African Journals Online (AJOL)

    Methods: A qualitative study with snowball sampling technique was used to identify fifteen dispensers working in community pharmacies in Islamabad, Peshawar and Lahore. Semi-structured interviews were conducted with the dispensers until the point of saturation was obtained. The interviews which focused on three ...

  8. Labelling of equipment dispensers.

    Science.gov (United States)

    Gray, D C

    1993-01-01

    A new labelling system for use on medical equipment dispensers is tested. This system uses one of the objects stored in each unit of the dispenser as the 'label', by attaching it to the front of the dispenser with tape. The new system was compared to conventional written labelling by timing subjects asked to select items from two dispensers. The new system was 27% quicker than the conventional system. Images Fig. 1 PMID:8110335

  9. Perceptions of Dispensers Regarding Dispensing Practices in ...

    African Journals Online (AJOL)

    Methods: A qualitative study with snowball sampling technique was used to ... Semi-structured interviews were conducted with the dispensers until the ... and suggestions for improvements were audio-taped, transcribed verbatim and analyzed.

  10. Perceptions of Dispensers Regarding Dispensing Practices in ...

    African Journals Online (AJOL)

    Erah

    1School of Pharmaceutical Sciences, University Sains Malaysia, 11800 Penang, Malaysia, 2Department of Social ... working in community pharmacies in Islamabad, Peshawar and Lahore. ..... situation regarding dispensing practices in the.

  11. Fabrication and Measurement of Low Work Function Cesiated Dispenser Photocathodes

    CERN Document Server

    Moody, Nathan A; Jensen, Kevin

    2005-01-01

    Photoinjector performance is a limiting factor in the continued development of high powered FELs and electron beam-based accelerators. Presently available photocathodes are plagued with limited efficiency and short lifetime in an RF-gun environment, due to contamination or evaporation of a photosensitive surface layer. An ideal photocathode should have high efficiency at long wavelengths, long lifetime in practical vacuum environments, and prompt emission. Cathodes with high efficiency typically have limited lifetime, and vice versa, and the needs of the photocathode are generally at odds with those of the drive laser. A potential solution is the low work function dispenser cathode, where lifetime issues are overcome by periodic in situ regeneration that restores the photosensitive surface layer, analogous to those used in the microwave power tube industry. This work reports on the fabrication techniques and performance of cesiated metal photocathodes and cesiated dispenser cathodes, with a focus on understan...

  12. Safe pill-dispensing.

    Science.gov (United States)

    Testa, Massimiliano; Pollard, John

    2007-01-01

    Each patient is supplied with a smart-card containing a Radio Frequency IDentification (RFID) chip storing a unique identification code. The patient places the Smart-card on a pill-dispenser unit containing an RFID reader. The RFID chip is read and the code sent to a Base-station via a wireless Bluetooth link. A database containing both patient details and treatment information is queried at the Base-station using the RFID as the search key. The patient's treatment data (i.e., drug names, quantities, time, etc.) are retrieved and sent back to the pill-dispenser unit via Bluetooth. Appropriate quantities of the required medications are automatically dispensed, unless the patient has already taken his/her daily dose. Safe, confidential communication and operation is ensured.

  13. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  14. One-Stop Dispensing

    DEFF Research Database (Denmark)

    Houlind, Morten Baltzer; McNulty, Helle Bach Ølgaard; Treldal, Charlotte

    2018-01-01

    (1) Objective: To assess hospital medication costs and staff time between One-Stop Dispensing (OSD) and the Traditional Medication System (TMS), and to evaluate patient perspectives on OSD. (2) Methods: The study was conducted at Hvidovre Hospital, University of Copenhagen, Denmark in an elective...... gastric surgery and acute orthopedic surgery department. This study consists of three sub-studies including adult patients able to self-manage medication. In Sub-study 1, staff time used to dispense and administer medication in TMS was assessed. Medication cost and OSD staff time were collected in Sub......-study 2, while patient perspectives were assessed in Sub-study 3. Medication costs with two days of discharge medication were compared between measured OSD cost and simulated TMS cost for the same patients. Measured staff time in OSD was compared to simulated staff time in TMS for the same patients...

  15. E85 Dispenser Study

    Energy Technology Data Exchange (ETDEWEB)

    Moriarty, K.; Johnson, C.; Sears, T.; Bergeron, P.

    2009-12-01

    This study reviews E85 dispensing infrastructure advances and issues and evaluates the geographic concentration of flexible fuel vehicles (FFVs), E85 stations, ethanol production facilities, and E85 suppliers. Costs, space, financial incentives, and barriers to adding E85 fueling equipment at existing stations are also assessed. This study found that E85 is increasingly available in the U.S. in half of the states; however, the other half have minimal or no E85 fueling options. Despite these gains, E85 is only available at 1% of U.S. gasoline stations. Ethanol production reached 9.5 billion gallons in 2008, but less than 1% is consumed as E85. FFVs have not reached a significant concentration in any county, metropolitan area, or state.

  16. Modular Low-Heater-Power Cathode/Electron Gun Assembly for Microwave and Millimeter Wave Traveling Wave Tubes

    Science.gov (United States)

    Wintucky, Edwin G.

    2000-01-01

    A low-cost, low-mass, electrically efficient, modular cathode/electron gun assembly has been developed by FDE Inc. of Beaverton, Oregon, under a Small Business Innovation Research (SBIR) contract with the NASA Glenn Research Center at Lewis Field. This new assembly offers significant improvements in the design and manufacture of microwave and millimeter wave traveling-wave tubes (TWT's) used for radar and communications. It incorporates a novel, low-heater-power, reduced size and mass, high-performance barium dispenser type thermionic cathode and provides for easy integration of the cathode into a large variety of conventional TWT circuits. Among the applications are TWT's for Earth-orbiting communication satellites and for deep space communications, where future missions will require smaller spacecraft, higher data transfer rates (higher frequencies and radiofrequency output power), and greater electrical efficiency. A particularly important TWT application is in the microwave power module (a hybrid microwave/millimeter wave amplifier consisting of a low-noise solid-state driver, a small TWT, and an electronic power conditioner integrated into a single compact package), where electrical efficiency and thermal loading are critical factors and lower cost is needed for successful commercialization. The design and fabrication are based on practices used in producing cathode ray tubes (CRT's), which is one of the most competitive and efficient manufacturing operations in the world today. The approach used in the design and manufacture of thermionic cathodes and electron guns for CRT's has been optimized for fully automated production, standardization of parts, and minimization of costs. It is applicable to the production of similar components for microwave tubes, with the additional benefits of low mass and significantly lower cathode heater power (less than half that of dispenser cathodes presently used in TWT s). Modular cathode/electron gun assembly. The modular

  17. 21 CFR 888.4200 - Cement dispenser.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cement dispenser. 888.4200 Section 888.4200 Food... DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4200 Cement dispenser. (a) Identification. A cement dispenser is a nonpowered syringe-like device intended for use in placing bone cement (§ 888.3027) into...

  18. Barium depletion study on impregnated cathodes and lifetime prediction

    International Nuclear Information System (INIS)

    Roquais, J.M.; Poret, F.; Doze, R. le; Ricaud, J.L.; Monterrin, A.; Steinbrunn, A.

    2003-01-01

    In the thermionic cathodes used in cathode ray-tubes (CRTs), barium is the key element for the electronic emission. In the case of the dispenser cathodes made of a porous tungsten pellet impregnated with Ba, Ca aluminates, the evaporation of Ba determines the cathode lifetime with respect to emission performance in the CRT. The Ba evaporation results in progressive depletion of the impregnating material inside the pellet. In the present work, the Ba depletion with time has been extensively characterized over a large range of cathode temperature. Calculations using the depletion data allowed modeling of the depletion as a function of key parameters. The link between measured depletion and emission in tubes has been established, from which an end-of-life criterion was deduced. Taking modeling into account, predicting accelerated life-tests were performed using high-density maximum emission current (MIK)

  19. Measuring current emission and work functions of large thermionic cathodes

    International Nuclear Information System (INIS)

    Fortgang, C.M.

    2001-01-01

    As one component of the nations Stockpile Stewardship program, Los Alamos National Laboratory is constructing a 20 MeV, 2 kA (with a 4 kA upgrade capability), 3ps induction linac for doing x-ray radiography of explosive devices. The linac is one leg of a facility called the Dual-Axis Radiography Hydrodynamic Test Facility (DARHT). The electron gun is designed to operate at 3.2 MV. The gun is a Pierce type design and uses a 6.5' cathode for 2 kA operation and an 8' cathode for 4 kA operation. We have constructed a small facility called the Cathode Test Stand (CTS) to investigate engineering and physics issues regarding large thermionic dispenser-cathodes. In particular, we have looked at the issues of temperature uniformity on the cathode surface and cathode quality as measured by its work function. We have done thermal imaging of both 8' and 6.5' cathodes. Here we report on measurements of the cathode work function, both the average value and how it vanes across the face of the cathode.

  20. Dose dispenser for radioactive gas

    International Nuclear Information System (INIS)

    Horwitz, N.H.; Gutkowski, R.E.

    1977-01-01

    An activity metering apparatus for metering predetermined activities of radioactive gas from a supply ampul to dose vials is described. The apparatus includes a shielded ampul housing, a fine metering valve communicating with the ampul housing chamber, a shielded vial housing and a hypodermic needle communicating with the metering valve and received through an opening in the vial housing. A Geiger-Muller tube is adjustably supported opposite an opening in the vial housing, whereby the activity of the radioactive gas dispensed to a partially evacuated vial within the vial chamber may be read directly by a standard laboratory rate meter

  1. A compact 133Xe gas dispenser

    International Nuclear Information System (INIS)

    Hawkins, T.; Harris, R.

    1977-01-01

    A dispenser for 133 Xe gas is described which is compact and simple to use, allowing the xenon to be dispensed from it shipping ampoule to suitable multi-dose injection vials in a controlled manner and with a high degree of operator safety. The apparatus has no joints and only a single rubber teat, minimizing the risks of adsorption and leakage. A scaled drawing of the dispenser is shown. (U.K.)

  2. reliability reliability

    African Journals Online (AJOL)

    eobe

    Corresponding author, Tel: +234-703. RELIABILITY .... V , , given by the code of practice. However, checks must .... an optimization procedure over the failure domain F corresponding .... of Concrete Members based on Utility Theory,. Technical ...

  3. Nanotube cathodes.

    Energy Technology Data Exchange (ETDEWEB)

    Overmyer, Donald L.; Lockner, Thomas Ramsbeck; Siegal, Michael P.; Miller, Paul Albert

    2006-11-01

    Carbon nanotubes have shown promise for applications in many diverse areas of technology. In this report we describe our efforts to develop high-current cathodes from a variety of nanotubes deposited under a variety of conditions. Our goal was to develop a one-inch-diameter cathode capable of emitting 10 amperes of electron current for one second with an applied potential of 50 kV. This combination of current and pulse duration significantly exceeds previously reported nanotube-cathode performance. This project was planned for two years duration. In the first year, we tested the electron-emission characteristics of nanotube arrays fabricated under a variety of conditions. In the second year, we planned to select the best processing conditions, to fabricate larger cathode samples, and to test them on a high-power relativistic electron beam generator. In the first year, much effort was made to control nanotube arrays in terms of nanotube diameter and average spacing apart. When the project began, we believed that nanotubes approximately 10 nm in diameter would yield sufficient electron emission properties, based on the work of others in the field. Therefore, much of our focus was placed on measured field emission from such nanotubes grown on a variety of metallized surfaces and with varying average spacing between individual nanotubes. We easily reproduced the field emission properties typically measured by others from multi-wall carbon nanotube arrays. Interestingly, we did this without having the helpful vertical alignment to enhance emission; our nanotubes were randomly oriented. The good emission was most likely possible due to the improved crystallinity, and therefore, electrical conductivity, of our nanotubes compared to those in the literature. However, toward the end of the project, we learned that while these 10-nm-diameter CNTs had superior crystalline structure to the work of others studying field emission from multi-wall CNT arrays, these nanotubes still

  4. Nanotube cathodes

    International Nuclear Information System (INIS)

    Overmyer, Donald L.; Lockner, Thomas Ramsbeck; Siegal, Michael P.; Miller, Paul Albert

    2006-01-01

    Carbon nanotubes have shown promise for applications in many diverse areas of technology. In this report we describe our efforts to develop high-current cathodes from a variety of nanotubes deposited under a variety of conditions. Our goal was to develop a one-inch-diameter cathode capable of emitting 10 amperes of electron current for one second with an applied potential of 50 kV. This combination of current and pulse duration significantly exceeds previously reported nanotube-cathode performance. This project was planned for two years duration. In the first year, we tested the electron-emission characteristics of nanotube arrays fabricated under a variety of conditions. In the second year, we planned to select the best processing conditions, to fabricate larger cathode samples, and to test them on a high-power relativistic electron beam generator. In the first year, much effort was made to control nanotube arrays in terms of nanotube diameter and average spacing apart. When the project began, we believed that nanotubes approximately 10 nm in diameter would yield sufficient electron emission properties, based on the work of others in the field. Therefore, much of our focus was placed on measured field emission from such nanotubes grown on a variety of metallized surfaces and with varying average spacing between individual nanotubes. We easily reproduced the field emission properties typically measured by others from multi-wall carbon nanotube arrays. Interestingly, we did this without having the helpful vertical alignment to enhance emission; our nanotubes were randomly oriented. The good emission was most likely possible due to the improved crystallinity, and therefore, electrical conductivity, of our nanotubes compared to those in the literature. However, toward the end of the project, we learned that while these 10-nm-diameter CNTs had superior crystalline structure to the work of others studying field emission from multi-wall CNT arrays, these nanotubes still

  5. Antimalarial Drugs for Pediatrics - Prescribing and Dispensing ...

    African Journals Online (AJOL)

    Purpose: To assess dispensing and prescribing practices with regard to antimalarial drugs for pediatrics in private pharmacies and public hospitals in Dar es Salaam, Tanzania. Methods: This was a cross-sectional, descriptive study that assessed the knowledge and practice of 200 drug dispensers in the private community ...

  6. Dissolvable microneedle fabrication using piezoelectric dispensing technology.

    Science.gov (United States)

    Allen, Evin A; O'Mahony, Conor; Cronin, Michael; O'Mahony, Thomas; Moore, Anne C; Crean, Abina M

    2016-03-16

    Dissolvable microneedle (DMN) patches are novel dosage forms for the percutaneous delivery of vaccines. DMN are routinely fabricated by dispensing liquid formulations into microneedle-shaped moulds. The liquid formulation within the mould is then dried to create dissolvable vaccine-loaded microneedles. The precision of the dispensing process is critical to the control of formulation volume loaded into each dissolvable microneedle structure. The dispensing process employed must maintain vaccine integrity. Wetting of mould surfaces by the dispensed formulation is also an important consideration for the fabrication of sharp-tipped DMN. Sharp-tipped DMN are essential for ease of percutaneous administration. In this paper, we demonstrate the ability of a piezoelectric dispensing system to dispense picolitre formulation volumes into PDMS moulds enabling the fabrication of bilayer DMN. The influence of formulation components (trehalose and polyvinyl alcohol (PVA) content) and piezoelectric actuation parameters (voltage, frequency and back pressure) on drop formation is described. The biological integrity of a seasonal influenza vaccine following dispensing was investigated and maintained voltage settings of 30 V but undermined at higher settings, 50 and 80 V. The results demonstrate the capability of piezoelectric dispensing technology to precisely fabricate bilayer DMN. They also highlight the importance of identifying formulation and actuation parameters to ensure controlled droplet formulation and vaccine stabilisation. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Barium Depletion in Hollow Cathode Emitters

    Science.gov (United States)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2009-01-01

    The effect of tungsten erosion, transport and redeposition on the operation of dispenser hollow cathodes was investigated in detailed examinations of the discharge cathode inserts from an 8200 hour and a 30,352 hour ion engine wear test. Erosion and subsequent re-deposition of tungsten in the electron emission zone at the downstream end of the insert reduces the porosity of the tungsten matrix, preventing the ow of barium from the interior. This inhibits the interfacial reactions of the barium-calcium-aluminate impregnant with the tungsten in the pores. A numerical model of barium transport in the internal xenon discharge plasma shows that the barium required to reduce the work function in the emission zone can be supplied from upstream through the gas phase. Barium that flows out of the pores of the tungsten insert is rapidly ionized in the xenon discharge and pushed back to the emitter surface by the electric field and drag from the xenon ion flow. This barium ion flux is sufficient to maintain a barium surface coverage at the downstream end greater than 0.6, even if local barium production at that point is inhibited by tungsten deposits. The model also shows that the neutral barium pressure exceeds the equilibrium vapor pressure of the impregnant decomposition reaction over much of the insert length, so the reactions are suppressed. Only a small region upstream of the zone blocked by tungsten deposits is active and supplies the required barium. These results indicate that hollow cathode failure models based on barium depletion rates in vacuum dispenser cathodes are very conservative.

  8. Barium depletion in hollow cathode emitters

    International Nuclear Information System (INIS)

    Polk, James E.; Mikellides, Ioannis G.; Katz, Ira; Capece, Angela M.

    2016-01-01

    Dispenser hollow cathodes rely on a consumable supply of Ba released by BaO-CaO-Al 2 O 3 source material in the pores of a tungsten matrix to maintain a low work function surface. The examination of cathode emitters from long duration tests shows deposits of tungsten at the downstream end that appear to block the flow of Ba from the interior. In addition, a numerical model of Ba transport in the cathode plasma indicates that the Ba partial pressure in the insert may exceed the equilibrium vapor pressure of the dominant Ba-producing reaction, and it was postulated previously that this would suppress Ba loss in the upstream part of the emitter. New measurements of the Ba depletion depth from a cathode insert operated for 8200 h reveal that Ba loss is confined to a narrow region near the downstream end, confirming this hypothesis. The Ba transport model was modified to predict the depletion depth with time. A comparison of the calculated and measured depletion depths gives excellent qualitative agreement, and quantitative agreement was obtained assuming an insert temperature 70 °C lower than measured beginning-of-life values

  9. Direct-Dispense Polymeric Waveguides Platform for Optical Chemical Sensors

    Directory of Open Access Journals (Sweden)

    Mohamad Hajj-Hassan

    2008-12-01

    Full Text Available We describe an automated robotic technique called direct-dispense to fabricate a polymeric platform that supports optical sensor arrays. Direct-dispense, which is a type of the emerging direct-write microfabrication techniques, uses fugitive organic inks in combination with cross-linkable polymers to create microfluidic channels and other microstructures. Specifically, we describe an application of direct-dispensing to develop optical biochemical sensors by fabricating planar ridge waveguides that support sol-gelderived xerogel-based thin films. The xerogel-based sensor materials act as host media to house luminophore biochemical recognition elements. As a prototype implementation, we demonstrate gaseous oxygen (O2 responsive optical sensors that operate on the basis of monitoring luminescence intensity signals. The optical sensor employs a Light Emitting Diode (LED excitation source and a standard silicon photodiode as the detector. The sensor operates over the full scale (0%-100% of O2 concentrations with a response time of less than 1 second. This work has implications for the development of miniaturized multisensor platforms that can be cost-effectively and reliably mass-produced.

  10. Community pharmacists’ attitudes and knowledge on dispensing drugs.

    Directory of Open Access Journals (Sweden)

    Baldon JP

    2006-03-01

    Full Text Available The present study aimed to assess knowledge and attitudes of the pharmacists on dispensing drugs to pregnant women. Methods: Cross-sectional study in 150 community pharmacies randomly selected in Curitiba (Brazil. A closed end questionnaire with 25 questions were used, including dispensing scenarios containing risk types A, B, D or X and questions on pharmacist interaction with pregnant women, physicians, and information sources availability. Results: Pharmacists performed appropriately in 53% of the encounters. Lower success were associated to prednison and captopril (24.8% in both, end cases producing more doubts were captopril (31.7% and simvastatin (30.7%. Most of the pharmacists state have advised drugs to pregnant women or contact to the physician to discuss about a prescription related with this issue. A Majority (64.4% did not feel able to understand FDA risk classification and did not have trustable information sources in pharmacy. Conclusions: Pharmacists dispensing drugs in Curitiba are not able to interpret information on the use of drugs in pregnant women, and they don have reliable information sources on the use of dugs in pregnancy. However, they advice and counsel drugs to pregnant women and discuss with physicians therapeutic strategies.

  11. Cathodic protection -- Rectifier 46

    International Nuclear Information System (INIS)

    Lane, W.M.

    1995-01-01

    This Acceptance Test Procedure (ATP) has been prepared to demonstrate that the cathodic protection system functions as required by project criteria. The cathodic protection system is for the tank farms on the Hanford Reservation. The tank farms store radioactive waste

  12. Cathodic protection -- Rectifier 47

    International Nuclear Information System (INIS)

    Lane, W.M.

    1995-01-01

    This Acceptance Test Procedure (ATP) has been prepared to demonstrate that the cathodic protection system functions as required by project criteria. The cathodic protection system is for the tank farms at the Hanford Reservation. The tank farms store radioactive waste

  13. The effect of cathode geometry on barium transport in hollow cathode plasmas

    International Nuclear Information System (INIS)

    Polk, James E.; Mikellides, Ioannis G.; Katz, Ira; Capece, Angela M.

    2014-01-01

    The effect of barium transport on the operation of dispenser hollow cathodes was investigated in numerical modeling of a cathode with two different orifice sizes. Despite large differences in cathode emitter temperature, emitted electron current density, internal xenon neutral and plasma densities, and size of the plasma-surface interaction region, the barium transport in the two geometries is qualitatively very similar. Barium is produced in the insert and flows to the surface through the porous structure. A buildup of neutral Ba pressure in the plasma over the emitter surface can suppress the reactions supplying the Ba, restricting the net production rate. Neutral Ba flows into the dense Xe plasma and has a high probability of being ionized at the periphery of this zone. The steady state neutral Ba density distribution is determined by a balance between pressure gradient forces and the drag force associated with collisions between neutral Ba and neutral Xe atoms. A small fraction of the neutral Ba is lost upstream. The majority of the neutral Ba is ionized in the high temperature Xe plasma and is pushed back to the emitter surface by the electric field. The steady state Ba + ion density distribution results from a balance between electrostatic and pressure forces, neutral Xe drag and Xe + ion drag with the dominant forces dependent on location in the discharge. These results indicate that hollow cathodes are very effective at recycling Ba within the discharge and therefore maintain a high coverage of Ba on the emitter surface, which reduces the work function and sustains high electron emission current densities at moderate temperatures. Barium recycling is more effective in the cathode with the smaller orifice because the Ba is ionized in the dense Xe plasma concentrated just upstream of the orifice and pushed back into the hollow cathode. Despite a lower emitter temperature, the large orifice cathode has a higher Ba loss rate through the orifice because the Xe

  14. Prescription habits of dispensing and non-dispensing doctors in Zimbabwe

    DEFF Research Database (Denmark)

    Trap, Birna; Hansen, Ebba Holme; Hogerzeil, Hans V

    2002-01-01

    , race, place of education, location of practice and patients seen per day showed that dispensing by doctors was associated with less clinically and economically appropriate prescribing. These findings suggest that the quality of health care--as related to drug use, patient safety and treatment cost......The number of dispensing doctors has increased in the last decade, but the implication of this trend on the quality of health care and drug use is unknown. We present a comparative drug utilization study of 29 dispensing doctors and 28 non-dispensing doctors in Zimbabwe based on standard indicators...... developed by the World Health Organization. Dispensing doctors prescribed significantly more drugs per patient than non-dispensing doctors (2.3 versus 1.7), injected more patients (28.4% versus 9.5%), and prescribed more antibiotics (0.72 versus 0.54) and mixtures (0.43 versus 0.25) per encounter...

  15. Compact Rare Earth Emitter Hollow Cathode

    Science.gov (United States)

    Watkins, Ronald; Goebel, Dan; Hofer, Richard

    2010-01-01

    A compact, high-current, hollow cathode utilizing a lanthanum hexaboride (LaB6) thermionic electron emitter has been developed for use with high-power Hall thrusters and ion thrusters. LaB6 cathodes are being investigated due to their long life, high current capabilities, and less stringent xenon purity and handling requirements compared to conventional barium oxide (BaO) dispenser cathodes. The new cathode features a much smaller diameter than previously developed versions that permit it to be mounted on axis of a Hall thruster ( internally mounted ), as opposed to the conventional side-mount position external to the outer magnetic circuit ("externally mounted"). The cathode has also been reconfigured to be capable of surviving vibrational loads during launch and is designed to solve the significant heater and materials compatibility problems associated with the use of this emitter material. This has been accomplished in a compact design with the capability of high-emission current (10 to 60 A). The compact, high-current design has a keeper diameter that allows the cathode to be mounted on the centerline of a 6- kW Hall thruster, inside the iron core of the inner electromagnetic coil. Although designed for electric propulsion thrusters in spacecraft station- keeping, orbit transfer, and interplanetary applications, the LaB6 cathodes are applicable to the plasma processing industry in applications such as optical coatings and semiconductor processing where reactive gases are used. Where current electrical propulsion thrusters with BaO emitters have limited life and need extremely clean propellant feed systems at a significant cost, these LaB6 cathodes can run on the crudest-grade xenon propellant available without impact. Moreover, in a laboratory environment, LaB6 cathodes reduce testing costs because they do not require extended conditioning periods under hard vacuum. Alternative rare earth emitters, such as cerium hexaboride (CeB6) can be used in this

  16. Development of spark cathode E-guns. Draft final reprt, Phase I, July--October 1978

    International Nuclear Information System (INIS)

    Loda, G.; Lindstrand, R.

    1979-01-01

    A 12 sided spark cathode is designed and constructed to replace the bladed, cold cathode structure in the electron gun of the Los Alamos Scientific Laboratory Antares prototype power amplifier. Design work includes computer modeling and full scale low voltage modeling. Life testing to 100,000 pulses is documented. The spark cathode offers precise control of emission site location and a high reliability

  17. What motivates antibiotic dispensing in accredited drug dispensing outlets in Tanzania? A qualitative study.

    Science.gov (United States)

    Dillip, Angel; Embrey, Martha; Shekalaghe, Elizabeth; Ross-Degnan, Dennis; Vialle-Valentin, Catherine; Kimatta, Suleiman; Liana, Jafary; Rutta, Edmund; Valimba, Richard; Chalker, John

    2015-01-01

    Tanzania introduced the accredited drug dispensing outlet (ADDO) program more than a decade ago. Previous evaluations have generally shown that ADDOs meet defined standards of practice better than non-accredited outlets. However, ADDOs still face challenges with overuse of antibiotics for acute respiratory infections (ARI) and simple diarrhea, which contributes to the emergence of drug resistance. This study aimed to explore the attitudes of ADDO owners and dispensers toward antibiotic dispensing and to learn how accreditation has influenced their dispensing behavior. The study used a qualitative approach. We conducted in-depth interviews with ADDO owners and dispensers in Ruvuma and Tanga regions where the government implemented the ADDO program under centralized and decentralized approaches, respectively; a secondary aim was to compare differences between the two regions. Findings indicate that the ADDO program has brought about positive changes in knowledge of dispensing practices. Respondents were able to correctly explain treatment guidelines for ARI and diarrhea. Almost all dispensers and owners indicated that unnecessary use of antibiotics contributed to antimicrobial resistance. Despite this knowledge, translating it to appropriate dispensing practice is still low. Dispensers' behavior is driven by customer demand, habit ("mazoea"), following inappropriate health facility prescriptions, and the need to make a profit. Although the majority of dispensers reported that they had intervened in situations where customers asked for antibiotics unnecessarily, they tended to give in to clients' requests. Small variations were noted between the two study regions; for example, some dispensers in Ruvuma reported sending clients with incorrect prescriptions back to the health facility, a practice that may reflect regional differences in ADDO implementation and in Integrated Management of Childhood Illness training. Dispensers in rural settings reported more challenges

  18. Cathodic Protection Model Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Performs Navy design and engineering of ship and submarine impressed current cathodic protection (ICCP) systems for underwater hull corrosion control and...

  19. Development of plasma cathode electron guns

    Science.gov (United States)

    Oks, Efim M.; Schanin, Peter M.

    1999-05-01

    The status of experimental research and ongoing development of plasma cathode electron guns in recent years is reviewed, including some novel upgrades and applications to various technological fields. The attractiveness of this kind of e-gun is due to its capability of creating high current, broad or focused beams, both in pulsed and steady-state modes of operation. An important characteristic of the plasma cathode electron gun is the absence of a thermionic cathode, a feature which leads to long lifetime and reliable operation even in the presence of aggressive background gas media and at fore-vacuum gas pressure ranges such as achieved by mechanical pumps. Depending on the required beam parameters, different kinds of plasma discharge systems can be used in plasma cathode electron guns, such as vacuum arcs, constricted gaseous arcs, hollow cathode glows, and two kinds of discharges in crossed E×B fields: Penning and magnetron. At the present time, plasma cathode electron guns provide beams with transverse dimension from fractional millimeter up to about one meter, beam current from microamperes to kiloamperes, beam current density up to about 100 A/cm2, pulse duration from nanoseconds to dc, and electron energy from several keV to hundreds of keV. Applications include electron beam melting and welding, surface treatment, plasma chemistry, radiation technologies, laser pumping, microwave generation, and more.

  20. Alcohol Dispenser Training in Amherst Massachusetts

    Science.gov (United States)

    Riccelli, Carlene

    1986-01-01

    Reviews efforts of the Alcohol Dispenser Training program in Amherst, Massachusetts over a five-year period. Evaluations indicate that participants agree that training is worthwhile, that they are more aware of the effects of alcohol on their patrons, and that they have better knowledge of appropriate strategies for preventing intoxication of…

  1. 21 CFR 872.3080 - Mercury and alloy dispenser.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mercury and alloy dispenser. 872.3080 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a) Identification. A mercury and alloy dispenser is a device with a spring-activated valve intended to measure and...

  2. DARHT 2 kA Cathode Development

    Energy Technology Data Exchange (ETDEWEB)

    Henestroza, E.; Houck, T.; Kwan, J.W.; Leitner, M.; Miram, G.; Prichard, B.; Roy, P.K.; Waldron, W.; Westenskow, G.; Yu, S.; Bieniosek, F.M.

    2009-03-09

    In the campaign to achieve 2 kA of electron beam current, we have made several changes to the DARHT-II injector during 2006-2007. These changes resulted in a significant increase in the beam current, achieving the 2 kA milestone. Until recently (before 2007), the maximum beam current that was produced from the 6.5-inch diameter (612M) cathode was about 1300 A when the cathode was operating at a maximum temperature of 1140 C. At this temperature level, the heat loss was dominated by radiation which is proportional to temperature to the fourth power. The maximum operating temperature was limited by the damage threshold of the potted filament and the capacity of the filament heater power supply, as well as the shortening of the cathode life time. There were also signs of overheating at other components in the cathode assembly. Thus it was clear that our approach to increase beam current could not be simply trying to run at a higher temperature and the preferred way was to operate with a cathode that has a lower work function. The dispenser cathode initially used was the type 612M made by SpectraMat. According to the manufacturer's bulletin, this cathode should be able to produce more than 10 A/cm{sup 2} of current density (corresponding to 2 kA of total beam current) at our operating conditions. Instead the measured emission (space charge limited) was 6 A/cm{sup 2}. The result was similar even after we had revised the activation and handling procedures to adhere more closely to the recommend steps (taking longer time and nonstop to do the out-gassing). Vacuum was a major concern in considering the cathode's performance. Although the vacuum gauges at the injector vessel indicated 10{sup -8} Torr, the actual vacuum condition near the cathode in the central region of the vessel, where there might be significant out-gassing from the heater region, was never determined. Poor vacuum at the surface of the cathode degraded the emission (by raising the work function

  3. DARHT 2 kA Cathode Development

    International Nuclear Information System (INIS)

    Henestroza, E.; Houck, T.; Kwan, J.W.; Leitner, M.; Miram, G.; Prichard, B.; Roy, P.K.; Waldron, W.; Westenskow, G.; Yu, S.; Bieniosek, F.M.

    2009-01-01

    In the campaign to achieve 2 kA of electron beam current, we have made several changes to the DARHT-II injector during 2006-2007. These changes resulted in a significant increase in the beam current, achieving the 2 kA milestone. Until recently (before 2007), the maximum beam current that was produced from the 6.5-inch diameter (612M) cathode was about 1300 A when the cathode was operating at a maximum temperature of 1140 C. At this temperature level, the heat loss was dominated by radiation which is proportional to temperature to the fourth power. The maximum operating temperature was limited by the damage threshold of the potted filament and the capacity of the filament heater power supply, as well as the shortening of the cathode life time. There were also signs of overheating at other components in the cathode assembly. Thus it was clear that our approach to increase beam current could not be simply trying to run at a higher temperature and the preferred way was to operate with a cathode that has a lower work function. The dispenser cathode initially used was the type 612M made by SpectraMat. According to the manufacturer's bulletin, this cathode should be able to produce more than 10 A/cm 2 of current density (corresponding to 2 kA of total beam current) at our operating conditions. Instead the measured emission (space charge limited) was 6 A/cm 2 . The result was similar even after we had revised the activation and handling procedures to adhere more closely to the recommend steps (taking longer time and nonstop to do the out-gassing). Vacuum was a major concern in considering the cathode's performance. Although the vacuum gauges at the injector vessel indicated 10 -8 Torr, the actual vacuum condition near the cathode in the central region of the vessel, where there might be significant out-gassing from the heater region, was never determined. Poor vacuum at the surface of the cathode degraded the emission (by raising the work function value). We reexamined

  4. Nanostructured sulfur cathodes

    KAUST Repository

    Yang, Yuan

    2013-01-01

    Rechargeable Li/S batteries have attracted significant attention lately due to their high specific energy and low cost. They are promising candidates for applications, including portable electronics, electric vehicles and grid-level energy storage. However, poor cycle life and low power capability are major technical obstacles. Various nanostructured sulfur cathodes have been developed to address these issues, as they provide greater resistance to pulverization, faster reaction kinetics and better trapping of soluble polysulfides. In this review, recent developments on nanostructured sulfur cathodes and mechanisms behind their operation are presented and discussed. Moreover, progress on novel characterization of sulfur cathodes is also summarized, as it has deepened the understanding of sulfur cathodes and will guide further rational design of sulfur electrodes. © 2013 The Royal Society of Chemistry.

  5. Flow Channel Influence of a Collision-Based Piezoelectric Jetting Dispenser on Jet Performance

    Directory of Open Access Journals (Sweden)

    Can Zhou

    2018-04-01

    Full Text Available To improve the jet performance of a bi-piezoelectric jet dispenser, mathematical and simulation models were established according to the operating principle. In order to improve the accuracy and reliability of the simulation calculation, a viscosity model of the fluid was fitted to a fifth-order function with shear rate based on rheological test data, and the needle displacement model was fitted to a nine-order function with time based on real-time displacement test data. The results show that jet performance is related to the diameter of the nozzle outlet and the cone angle of the nozzle, and the impacts of the flow channel structure were confirmed. The approach of numerical simulation is confirmed by the testing results of droplet volume. It will provide a reliable simulation platform for mechanical collision-based jet dispensing and a theoretical basis for micro jet valve design and improvement.

  6. Development of automated blender and dispensing system

    International Nuclear Information System (INIS)

    Kulkarni, Anupama; Aherwal, P.; Patil, C.B.

    2014-01-01

    This paper describes automated blender and dispensing system designed and developed in Nuclear Recycle Board for its reprocessing plant. Obtaining sinterable grade oxide powder from the product solution received in the heavy metal product line involves skilled manpower and time consuming, laborious manual operations. Entire treatment is carried out in a train of closed containments called as glove boxes. In view of this Automated blender and dispensing system has been developed to reduce tedious manual operations. System consists of PLC based control system to drive motorised charging mechanism, a conical ribbon blender which homogenises the product and load cell triggered, indexing dispensing mechanism. Schematic design of the system has been done in-house, while fabrication was outsourced. System has been built, tested and installed at component test facility (CTF) at Tarapur. Actual blending tests were carried out by using dummy material like calcium carbonate and barium carbonate powder, with different sets of parameter. Blended product was chemically analysed for its homogeneity. System has now been put to trial runs by operating staff. This development has circumvented tedious operations of Scooping and increased the throughput. This paper describes challenges in undertaking this developmental work. (author)

  7. Arcjet cathode phenomena

    Science.gov (United States)

    Curran, Francis M.; Haag, Thomas W.; Raquet, John F.

    1989-01-01

    Cathode tips made from a number of different materials were tested in a modular arcjet thruster in order to examine cathode phenomena. Periodic disassembly and examination, along with the data collected during testing, indicated that all of the tungsten-based materials behaved similarly despite the fact that in one of these samples the percentage of thorium oxide was doubled and another was 25 percent rhenium. The mass loss rate from a 2 percent thoriated rhenium cathode was found to be an order of magnitude greater than that observed using 2 percent thoriated tungsten. Detailed analysis of one of these cathode tips showed that the molten crater contained pure tungsten to a depth of about 150 microns. Problems with thermal stress cracking were encountered in the testing of a hafnium carbide tip. Post test analysis showed that the active area of the tip had chemically reacted with the propellant. A 100 hour continuous test was run at about 1 kW. Post test analysis revealed no dendrite formation, such as observed in a 30 kW arcjet lifetest, near the cathode crater. The cathodes from both this test and a previously run 1000 hour cycled test displayed nearly identical arc craters. Data and calculations indicate that the mass losses observed in testing can be explained by evaporation.

  8. Tailored Core Shell Cathode Powders for Solid Oxide Fuel Cells

    Energy Technology Data Exchange (ETDEWEB)

    Swartz, Scott [NexTech Materials, Ltd.,Lewis Center, OH (United States)

    2015-03-23

    In this Phase I SBIR project, a “core-shell” composite cathode approach was evaluated for improving SOFC performance and reducing degradation of lanthanum strontium cobalt ferrite (LSCF) cathode materials, following previous successful demonstrations of infiltration approaches for achieving the same goals. The intent was to establish core-shell cathode powders that enabled high performance to be obtained with “drop-in” process capability for SOFC manufacturing (i.e., rather than adding an infiltration step to the SOFC manufacturing process). Milling, precipitation and hetero-coagulation methods were evaluated for making core-shell composite cathode powders comprised of coarse LSCF “core” particles and nanoscale “shell” particles of lanthanum strontium manganite (LSM) or praseodymium strontium manganite (PSM). Precipitation and hetero-coagulation methods were successful for obtaining the targeted core-shell morphology, although perfect coverage of the LSCF core particles by the LSM and PSM particles was not obtained. Electrochemical characterization of core-shell cathode powders and conventional (baseline) cathode powders was performed via electrochemical impedance spectroscopy (EIS) half-cell measurements and single-cell SOFC testing. Reliable EIS testing methods were established, which enabled comparative area-specific resistance measurements to be obtained. A single-cell SOFC testing approach also was established that enabled cathode resistance to be separated from overall cell resistance, and for cathode degradation to be separated from overall cell degradation. The results of these EIS and SOFC tests conclusively determined that the core-shell cathode powders resulted in significant lowering of performance, compared to the baseline cathodes. Based on the results of this project, it was concluded that the core-shell cathode approach did not warrant further investigation.

  9. Effect of scandia doping method on the emission uniformity of scandate cathode with Sc2O3–W matrix

    International Nuclear Information System (INIS)

    Wang, Jinshu; Lai, Chen; Liu, Wei; Yang, Fan; Zhang, Xizhu; Cui, Yuntao; Zhou, Meiling

    2013-01-01

    Graphical abstract: Emission uniformity of the cathodes prepared by mechanical mixing (a) and spray drying method (b). - Highlights: • The emission uniformity of scandate cathodes has been quantitively obtained. • The nanoparticles on the cathode surface lead to the electric field enhancement. • The cathode prepared by spray drying method exhibits good emission uniformity. - Abstract: Scandia doped tungsten matrix dispenser cathodes were manufactured using scandia doped tungsten powder prepared by mechanical mixing, liquid–solid doping and a spray drying method. It is found the macrostructure of the cathode depended on the powder preparation method. The cathode prepared using the powder prepared by spray drying method had a homogenous and porous matrix characterized with grains with a diameter of less than 1 μm and with many nanoparticles distributing uniformly around these grains. The cathode with submicron structure and uniform distribution of scandia exhibited good emission uniformity. The emission uniformity ΔJ/J of the cathode prepared by spray drying method was 0.17, about 6 times lower than that of the cathode prepared by mechanical mixing method. The calculation results showed that the nanoparticles led to electric field enhancement. A Ba–Sc–O multilayer on the cathode surface and nanoparticles distributing mainly on W grains contributed to the emission property of the cathode

  10. Effect of scandia doping method on the emission uniformity of scandate cathode with Sc{sub 2}O{sub 3}–W matrix

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jinshu, E-mail: wangjsh@bjut.edu.cn; Lai, Chen; Liu, Wei; Yang, Fan; Zhang, Xizhu; Cui, Yuntao; Zhou, Meiling

    2013-09-01

    Graphical abstract: Emission uniformity of the cathodes prepared by mechanical mixing (a) and spray drying method (b). - Highlights: • The emission uniformity of scandate cathodes has been quantitively obtained. • The nanoparticles on the cathode surface lead to the electric field enhancement. • The cathode prepared by spray drying method exhibits good emission uniformity. - Abstract: Scandia doped tungsten matrix dispenser cathodes were manufactured using scandia doped tungsten powder prepared by mechanical mixing, liquid–solid doping and a spray drying method. It is found the macrostructure of the cathode depended on the powder preparation method. The cathode prepared using the powder prepared by spray drying method had a homogenous and porous matrix characterized with grains with a diameter of less than 1 μm and with many nanoparticles distributing uniformly around these grains. The cathode with submicron structure and uniform distribution of scandia exhibited good emission uniformity. The emission uniformity ΔJ/J of the cathode prepared by spray drying method was 0.17, about 6 times lower than that of the cathode prepared by mechanical mixing method. The calculation results showed that the nanoparticles led to electric field enhancement. A Ba–Sc–O multilayer on the cathode surface and nanoparticles distributing mainly on W grains contributed to the emission property of the cathode.

  11. Cathode materials review

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Claus, E-mail: danielc@ornl.gov; Mohanty, Debasish, E-mail: danielc@ornl.gov; Li, Jianlin, E-mail: danielc@ornl.gov; Wood, David L., E-mail: danielc@ornl.gov [Oak Ridge National Laboratory, 1 Bethel Valley Road, MS6472 Oak Ridge, TN 37831-6472 (United States)

    2014-06-16

    The electrochemical potential of cathode materials defines the positive side of the terminal voltage of a battery. Traditionally, cathode materials are the energy-limiting or voltage-limiting electrode. One of the first electrochemical batteries, the voltaic pile invented by Alessandro Volta in 1800 (Phil. Trans. Roy. Soc. 90, 403-431) had a copper-zinc galvanic element with a terminal voltage of 0.76 V. Since then, the research community has increased capacity and voltage for primary (nonrechargeable) batteries and round-trip efficiency for secondary (rechargeable) batteries. Successful secondary batteries have been the lead-acid with a lead oxide cathode and a terminal voltage of 2.1 V and later the NiCd with a nickel(III) oxide-hydroxide cathode and a 1.2 V terminal voltage. The relatively low voltage of those aqueous systems and the low round-trip efficiency due to activation energies in the conversion reactions limited their use. In 1976, Wittingham (J. Electrochem. Soc., 123, 315) and Besenhard (J. Power Sources 1(3), 267) finally enabled highly reversible redox reactions by intercalation of lithium ions instead of by chemical conversion. In 1980, Goodenough and Mizushima (Mater. Res. Bull. 15, 783-789) demonstrated a high-energy and high-power LiCoO{sub 2} cathode, allowing for an increase of terminal voltage far beyond 3 V. Over the past four decades, the international research community has further developed cathode materials of many varieties. Current state-of-the-art cathodes demonstrate voltages beyond any known electrolyte stability window, bringing electrolyte research once again to the forefront of battery research.

  12. Cathode materials review

    International Nuclear Information System (INIS)

    Daniel, Claus; Mohanty, Debasish; Li, Jianlin; Wood, David L.

    2014-01-01

    The electrochemical potential of cathode materials defines the positive side of the terminal voltage of a battery. Traditionally, cathode materials are the energy-limiting or voltage-limiting electrode. One of the first electrochemical batteries, the voltaic pile invented by Alessandro Volta in 1800 (Phil. Trans. Roy. Soc. 90, 403-431) had a copper-zinc galvanic element with a terminal voltage of 0.76 V. Since then, the research community has increased capacity and voltage for primary (nonrechargeable) batteries and round-trip efficiency for secondary (rechargeable) batteries. Successful secondary batteries have been the lead-acid with a lead oxide cathode and a terminal voltage of 2.1 V and later the NiCd with a nickel(III) oxide-hydroxide cathode and a 1.2 V terminal voltage. The relatively low voltage of those aqueous systems and the low round-trip efficiency due to activation energies in the conversion reactions limited their use. In 1976, Wittingham (J. Electrochem. Soc., 123, 315) and Besenhard (J. Power Sources 1(3), 267) finally enabled highly reversible redox reactions by intercalation of lithium ions instead of by chemical conversion. In 1980, Goodenough and Mizushima (Mater. Res. Bull. 15, 783-789) demonstrated a high-energy and high-power LiCoO 2 cathode, allowing for an increase of terminal voltage far beyond 3 V. Over the past four decades, the international research community has further developed cathode materials of many varieties. Current state-of-the-art cathodes demonstrate voltages beyond any known electrolyte stability window, bringing electrolyte research once again to the forefront of battery research

  13. Cathode materials review

    Science.gov (United States)

    Daniel, Claus; Mohanty, Debasish; Li, Jianlin; Wood, David L.

    2014-06-01

    The electrochemical potential of cathode materials defines the positive side of the terminal voltage of a battery. Traditionally, cathode materials are the energy-limiting or voltage-limiting electrode. One of the first electrochemical batteries, the voltaic pile invented by Alessandro Volta in 1800 (Phil. Trans. Roy. Soc. 90, 403-431) had a copper-zinc galvanic element with a terminal voltage of 0.76 V. Since then, the research community has increased capacity and voltage for primary (nonrechargeable) batteries and round-trip efficiency for secondary (rechargeable) batteries. Successful secondary batteries have been the lead-acid with a lead oxide cathode and a terminal voltage of 2.1 V and later the NiCd with a nickel(III) oxide-hydroxide cathode and a 1.2 V terminal voltage. The relatively low voltage of those aqueous systems and the low round-trip efficiency due to activation energies in the conversion reactions limited their use. In 1976, Wittingham (J. Electrochem. Soc., 123, 315) and Besenhard (J. Power Sources 1(3), 267) finally enabled highly reversible redox reactions by intercalation of lithium ions instead of by chemical conversion. In 1980, Goodenough and Mizushima (Mater. Res. Bull. 15, 783-789) demonstrated a high-energy and high-power LiCoO2 cathode, allowing for an increase of terminal voltage far beyond 3 V. Over the past four decades, the international research community has further developed cathode materials of many varieties. Current state-of-the-art cathodes demonstrate voltages beyond any known electrolyte stability window, bringing electrolyte research once again to the forefront of battery research.

  14. A Simulated Learning Environment for Teaching Medicine Dispensing Skills.

    Science.gov (United States)

    McDowell, Jenny; Styles, Kim; Sewell, Keith; Trinder, Peta; Marriott, Jennifer; Maher, Sheryl; Naidu, Som

    2016-02-25

    To develop an authentic simulation of the professional practice dispensary context for students to develop their dispensing skills in a risk-free environment. A development team used an Agile software development method to create MyDispense, a web-based simulation. Modeled on virtual learning environments elements, the software employed widely available standards-based technologies to create a virtual community pharmacy environment. Assessment. First-year pharmacy students who used the software in their tutorials, were, at the end of the second semester, surveyed on their prior dispensing experience and their perceptions of MyDispense as a tool to learn dispensing skills. The dispensary simulation is an effective tool for helping students develop dispensing competency and knowledge in a safe environment.

  15. Prescription, dispensation and marketing patterns of methylphenidate

    Directory of Open Access Journals (Sweden)

    Edson Perini

    2014-12-01

    Full Text Available OBJECTIVE To analyze the patterns and legal requirements of methylphenidate consumption. METHODS We conducted a cross-sectional study of the data from prescription notification forms and balance lists of drugs sales – psychoactive and others – subject to special control in the fifth largest city of Brazil, in 2006. We determined the defined and prescribed daily doses, the average prescription and dispensation periods, and the regional sales distribution in the municipality. In addition, we estimated the costs of drug acquisition and analyzed the individual drug consumption profile using the Lorenz curve. RESULTS The balance lists data covered all notified sales of the drug while data from prescription notification forms covered 50.6% of the pharmacies that sold it, including those with the highest sales volumes. Total methylphenidate consumption was 0.37 DDD/1,000 inhabitants/day. Sales were concentrated in more developed areas, and regular-release tablets were the most commonly prescribed pharmaceutical formulation. In some regions of the city, approximately 20.0% of the prescriptions and dispensation exceeded 30 mg/day and 30 days of treatment. CONCLUSIONS Methylphenidate was widely consumed in the municipality and mainly in the most developed areas. Of note, the consumption of formulations with the higher abuse risk was the most predominant. Both its prescription and dispensation contrasted with current pharmacotherapeutic recommendations and legal requirements. Therefore, the commercialization of methylphenidate should be monitored more closely, and its use in the treatment of behavioral changes of psychological disorders needs to be discussed in detail, in line with the concepts of the quality use of medicines.

  16. Filtered cathodic arc source

    International Nuclear Information System (INIS)

    Falabella, S.; Sanders, D.M.

    1994-01-01

    A continuous, cathodic arc ion source coupled to a macro-particle filter capable of separation or elimination of macro-particles from the ion flux produced by cathodic arc discharge is described. The ion source employs an axial magnetic field on a cathode (target) having tapered sides to confine the arc, thereby providing high target material utilization. A bent magnetic field is used to guide the metal ions from the target to the part to be coated. The macro-particle filter consists of two straight solenoids, end to end, but placed at 45 degree to one another, which prevents line-of-sight from the arc spot on the target to the parts to be coated, yet provides a path for ions and electrons to flow, and includes a series of baffles for trapping the macro-particles. 3 figures

  17. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    Science.gov (United States)

    de Vos, Marc; Torah, Russel; Tudor, John

    2016-04-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps.

  18. Structure Design and Realization of Rapid Medicine Dispensing System

    Science.gov (United States)

    Liu, Xiangquan

    In this paper, the main components and function of rapid medicine dispensing system is analyzed, structure design of automatic feeding device, sloping storeroom, automatic dispensing device and automatic sorting device is completed. The system adopts medicine conveyer working in with manipulator to realize automatic batch supply of the boxed medicine, adopts sloping storeroom as warehouse of medicine to realize dense depositing, adopts dispensing mechanism which includes elevator, turning panel and electric magnet to realize rapid medicine dispensing, adopts sorting conveyor belt and sorting device to send medicine to designated outlet.

  19. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2500... a mechanical device intended for medical purposes to dispense or serially dilute very small...

  20. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    International Nuclear Information System (INIS)

    De Vos, Marc; Torah, Russel; Tudor, John

    2016-01-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps. (paper)

  1. Application of M-type cathodes to high-power cw klystrons

    Science.gov (United States)

    Isagawa, S.; Higuchi, T.; Kobayashi, K.; Miyake, S.; Ohya, K.; Yoshida, M.

    1999-05-01

    Two types of high-power cw klystrons have been widely used at KEK in both TRISTAN and KEKB e +e - collider projects: one is a 0.8 MW/1.0 MW tube, called YK1302/YK1303 (Philips); the other is a 1.2 MW tube, called E3786/E3732 (Toshiba). Normally, the dispenser cathodes of the `B-type' and the `S-type' have been used, respectively, but for improved versions they have been replaced by low-temperature cathodes, called the `M-type'. An Os/Ru coating was applied to the former, whereas an Ir one was applied to the latter. Until now, all upgraded tubes installing M-type cathodes, 9 and 8 in number, respectively, have worked successfully without any dropout. A positive experience concerning the lifetime under real operation conditions has been obtained. M-type cathodes are, however, more easily poisoned. One tube installing an Os/Ru-coated cathode showed a gradual, and then sudden decrease in emission during an underheating test, although the emission could fortunately be recovered by aging at the KEK test field. Once sufficiently aged, the emission of an Ir-coated cathode proved to be very high and stable, and its lifetime is expected to be very long. One disadvantage of this cathode is, however, susceptibility to gas poisoning and the necessity of long-term initial aging. New techniques, like ion milling and fine-grained tungsten top layers, were not as successful as expected from their smaller scale applications to shorten the initial aging period. A burn-in process at higher cathode loading was efficient to make the poisoned cathode active and to decrease unwanted Wehnelt emission. On top of that, the emission cooling, and thus thermal conductivity near the emitting layer could play an important role in such large-current cathodes as ours.

  2. Cathode material for lithium batteries

    Science.gov (United States)

    Park, Sang-Ho; Amine, Khalil

    2013-07-23

    A method of manufacture an article of a cathode (positive electrode) material for lithium batteries. The cathode material is a lithium molybdenum composite transition metal oxide material and is prepared by mixing in a solid state an intermediate molybdenum composite transition metal oxide and a lithium source. The mixture is thermally treated to obtain the lithium molybdenum composite transition metal oxide cathode material.

  3. Smart cathodic protection systems

    NARCIS (Netherlands)

    Polder, R.B.; Leggedoor, J.; Schuten, G.; Sajna, S.; Kranjc, A.

    2010-01-01

    Cathodic protection delivers corrosion protection in concrete structures exposed to aggressive environments, e.g. in de-icing salt and marine climates. Working lives of a large number of CP systems are at least more than 13 years and probably more than 25 years, provided a minimum level of

  4. Evaluation and remediation of bulk soap dispensers for biofilm.

    Science.gov (United States)

    Lorenz, Lindsey A; Ramsay, Bradley D; Goeres, Darla M; Fields, Matthew W; Zapka, Carrie A; Macinga, David R

    2012-01-01

    Recent studies evaluating bulk soap in public restroom soap dispensers have demonstrated up to 25% of open refillable bulk-soap dispensers were contaminated with ~ 6 log(10)(CFU ml(-1)) heterotrophic bacteria. In this study, plastic counter-mounted, plastic wall-mounted and stainless steel wall-mounted dispensers were analyzed for suspended and biofilm bacteria using total cell and viable plate counts. Independent of dispenser type or construction material, the bulk soap was contaminated with 4-7 log(10)(CFU ml(-1)) bacteria, while 4-6 log(10)(CFU cm(-2)) biofilm bacteria were isolated from the inside surfaces of the dispensers (n = 6). Dispenser remediation studies, including a 10 min soak with 5000 mg l(-1) sodium hypochlorite, were then conducted to determine the efficacy of cleaning and disinfectant procedures against established biofilms. The testing showed that contamination of the bulk soap returned to pre-test levels within 7-14 days. These results demonstrate biofilm is present in contaminated bulk-soap dispensers and remediation studies to clean and sanitize the dispensers are temporary.

  5. Impact of Robotic Dispensing Machines in German Pharmacies on ...

    African Journals Online (AJOL)

    To assess the impact of robotic dispensing machines in community pharmacies on staff efficiency and sales of over-the-counter drugs. Setting: The study was done on 253 community pharmacies in Germany that use a robotic dispensing machine manufactured by ROWA during 2008. Method: Data concerning the financial ...

  6. Anthelmintic drug dispensing in South Africa: An analysis of ...

    African Journals Online (AJOL)

    More than two billion people worldwide are infected with helminths. The primary aim of the study was to evaluate the dispensing patterns of anthelmintic products using dispensing data of South African community pharmacies. A retrospective, cross-sectional drug utilisation study was conducted on a 2013 community ...

  7. 14 CFR 137.39 - Economic poison dispensing.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Economic poison dispensing. 137.39 Section... AIRCRAFT OPERATIONS Operating Rules § 137.39 Economic poison dispensing. (a) Except as provided in... economic poison that is registered with the U.S. Department of Agriculture under the Federal Insecticide...

  8. Trends in radiopharmaceutical dispensing in a regional nuclear pharmacy

    International Nuclear Information System (INIS)

    Basmadjian, G.P.; Johnston, J.; Barker, K.; Ice, R.D.

    1982-01-01

    Dispensing trends for radiopharmaceuticals at a regional nuclear pharmacy over a 51-month period were studied. dispensing records of a regional nuclear pharmacy were analyzed with a forecasting procedure that uses univariate time data to produce time trends and autoregressive models. The overall number of prescriptions increased from 3500 to 5500 per quarter. Radiopharmaceuticals used in nuclear cardiology studies increased from less than 0.1% to 17.5% of total prescriptions dispensed, while radiopharmaceuticals used for brain imaging showed a steady decline from 29% to 11% of total prescriptions dispensed. The demand for other radiopharmaceuticals increased in areas such as renal studies, bone studies, lung studies, liver-function studies, and 67 Ga tumor-uptake studies, and declined slightly for static liver studies. Changes in dispensing trends for radiopharmaceuticals will continue as the practice of nuclear medicine concentrates more on functional studies and as newer imaging techniques become used for other purposes

  9. Barium Depletion in the NSTAR Discharge Cathode After 30,000 Hours of Operation

    Science.gov (United States)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2010-01-01

    Dispenser hollow cathodes rely on a consumable supply of barium released by impregnant materials in the pores of a tungsten matrix to maintain a low work function surface. Examinations of cathode inserts from long duration ion engine tests show deposits of tungsten at the downstream end that appear to block the flow of barium from the interior. In addition, a numerical model of barium transport in the insert plasma indicates that the barium partial pressure in the insert may exceed the equilibrium vapor pressure of the dominant barium-producing reaction, and it was postulated previously that this would suppress barium loss in the upstream part of the insert. New measurements of the depth of barium depletion from a cathode insert operated for 30,352 hours reveal that barium loss is confined to a narrow region near the downstream end, confirming this hypothesis.

  10. Efficiency control of cathodic protection measured using passivation verification technique in different concrete structures

    NARCIS (Netherlands)

    Martínez, I.; Andrade, C.; Vennesland, O.; Evensen, U.; Polder, R.B.; Leggedor, J.

    2007-01-01

    It is well known that cathodic protection is the most useful method for stopping corrosion when the deterioration process has started, but the most important issue that is still missing in the cathodic protection studies is how to check its efficiency in a reliable way. This paper presents results

  11. Air cathode structure manufacture

    Science.gov (United States)

    Momyer, William R.; Littauer, Ernest L.

    1985-01-01

    An improved air cathode structure for use in primary batteries and the like. The cathode structure includes a matrix active layer, a current collector grid on one face of the matrix active layer, and a porous, nonelectrically conductive separator on the opposite face of the matrix active layer, the collector grid and separator being permanently bonded to the matrix active layer. The separator has a preselected porosity providing low IR losses and high resistance to air flow through the matrix active layer to maintain high bubble pressure during operation of the battery. In the illustrated embodiment, the separator was formed of porous polypropylene. A thin hydrophobic film is provided, in the preferred embodiment, on the current collecting metal grid.

  12. Cathode ray tube screens

    International Nuclear Information System (INIS)

    Cockayne, B.; Robbins, D.J.; Glasper, J.L.

    1982-01-01

    An improved cathode ray tube screen is described which consists of a single- or a poly-crystalline slice of a material such as yttrium aluminium garnet in which dopants such as Tb 3 + , Eu 3 + , Ce 3 + or Tm 3 + are ion implanted to different depths or in different areas of the screen. Annealing the screen removes lattice damage caused by the ion implanting and assists the diffusion of the dopant into the crystal. (U.K.)

  13. Arc cathode spots

    International Nuclear Information System (INIS)

    Schrade, H.O.

    1989-01-01

    Arc spots are usually highly unstable and jump statistically over the cathode surface. In a magnetic field parallel to the surface, preferably they move in the retrograde direction; i.e., opposite to the Lorentzian rule. If the field is inclined with respect to the surface, the spots drift away at a certain angle with respect to the proper retrograde direction (Robson drift motion). These well-known phenomena are explained by one stability theory

  14. Cathode ray tube

    International Nuclear Information System (INIS)

    1979-01-01

    A cathode ray tube comprises two electron lens means in combination to crossover the electron beam at a second crossover between the two electron lens means with one of the two lens means having a variable voltage applied thereto to control the location of the beam crossover in order to focus the beam onto a display screen at any location away from the screen center. (Auth.)

  15. X-Band Thermionic Cathode RF Gun at UTNL

    CERN Document Server

    Fukasawa, Atsushi; Dobashi, Katsuhiro; Ebina, Futaro; Hayano, Hitoshi; Higo, Toshiyasu; Kaneyasu, Tatsuo; Matsuo, Kennichi; Ogino, Haruyuki; Sakae, Hisaharu; Sakamoto, Fumito; Uesaka, Mitsuru; Urakawa, Junji

    2005-01-01

    The X-band (11.424 GHz) linac for compact Compton scattering hard X-ray source are under construction at Nuclear Engineering Research Laboratory, University of Tokyo. This linac designed to accelerate up to 35 MeV, and this electron beam will be used to produce hard X-ray by colliding with laser. It consists of a thermionic cathode RF gun, an alpha magnet, and a traveling wave tube. The gun has 3.5 cells (unloaded Q is 8250) and will be operated at pi-mode. A dispenser cathode is introduced. Since the energy spread of the beam from the gun is predicted to be broad due to the continuous emission from the thermionic cathode, a slit is placed in the alpha magnet to eliminate low energy electrons. The simulation on the injector shows the beam energy 2.9 MeV, the charge 23 pC/bunch, and the emittance less than 10 mm.mrad. The experiment on the gun is planed in the beginning of 2005, and the details will be discussed on the spot.

  16. Reliability engineering

    International Nuclear Information System (INIS)

    Lee, Chi Woo; Kim, Sun Jin; Lee, Seung Woo; Jeong, Sang Yeong

    1993-08-01

    This book start what is reliability? such as origin of reliability problems, definition of reliability and reliability and use of reliability. It also deals with probability and calculation of reliability, reliability function and failure rate, probability distribution of reliability, assumption of MTBF, process of probability distribution, down time, maintainability and availability, break down maintenance and preventive maintenance design of reliability, design of reliability for prediction and statistics, reliability test, reliability data and design and management of reliability.

  17. Application of basic pharmacology and dispensing practice of antibiotics in accredited drug-dispensing outlets in Tanzania

    Directory of Open Access Journals (Sweden)

    Minzi OM

    2013-01-01

    Full Text Available OM Minzi,1 VS Manyilizu21Unit of Pharmacology and Therapeutics, School of Pharmacy, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania, 2Logistics System Strengthening Unit, John Snow Inc, Dar es Salaam, TanzaniaBackground: Provision of pharmaceutical services in accredited drug-dispensing outlets (ADDOs in Tanzania has not been reported. This study compared the antibiotics dispensing practice between ADDOs and part II shops, or duka la dawa baridi (DLDBs, in Tanzania.Methodology: This was a cross-sectional study that was conducted in ADDOs and DLDBs. A simulated client method for data collection was used, and a total of 85 ADDOs, located in Mvomero, Kilombero, and Morogoro rural districts, were compared with 60 DLDBs located in Kibaha district. The research assistants posed as simulated clients and requested to buy antibiotics from ADDOs and DLDBs after presenting a case scenario or disease condition. Among the diseases presented were those requiring antibiotics and those usually managed only by oral rehydration salt or analgesics. The simulated clients wanted to know the antibiotics that were available at the shop. The posed questions set a convincing ground to the dispenser either to dispense the antibiotic directly, request a prescription, or refer the patient to a health facility. Proportions were used to summarize categorical variables between ADDOs and DLDBs, and the chi-square test was used to test for statistical difference between the two drug-outlet types in terms of antibiotic-dispensing practice.Results: As many as 40% of trained ADDO dispensers no longer worked at the ADDO shops, so some of the shops employed untrained staff. A larger proportion of ADDOs than DLDBs dispensed antibiotics without prescriptions (P = 0.004. The overall results indicate that there was no difference between the two types of shops in terms of adhering to regulations for dispensing antibiotics. However, in some circumstances, eg

  18. On the actual cathode mixed potential in direct methanol fuel cells

    Science.gov (United States)

    Zago, M.; Bisello, A.; Baricci, A.; Rabissi, C.; Brightman, E.; Hinds, G.; Casalegno, A.

    2016-09-01

    Methanol crossover is one of the most critical issues hindering commercialization of direct methanol fuel cells since it leads to waste of fuel and significantly affects cathode potential, forming a so-called mixed potential. Unfortunately, due to the sluggish anode kinetics, it is not possible to obtain a reliable estimation of cathode potential by simply measuring the cell voltage. In this work we address this limitation, quantifying the mixed potential by means of innovative open circuit voltage (OCV) tests with a methanol-hydrogen mixture fed to the anode. Over a wide range of operating conditions, the resulting cathode overpotential is between 250 and 430 mV and is strongly influenced by methanol crossover. We show using combined experimental and modelling analysis of cathode impedance that the methanol oxidation at the cathode mainly follows an electrochemical pathway. Finally, reference electrode measurements at both cathode inlet and outlet provide a local measurement of cathode potential, confirming the reliability of the innovative OCV tests and permitting the evaluation of cathode potential up to typical operating current. At 0.25 A cm-2 the operating cathode potential is around 0.85 V and the Ohmic drop through the catalyst layer is almost 50 mV, which is comparable to that in the membrane.

  19. Cathodic protection of reinforced concrete structures in the Netherlands - Experience and developments: Cathodic protection of concrete - 10 years experience

    NARCIS (Netherlands)

    Polder, R.B.

    1998-01-01

    Cathodic protection (CP) of reinforcing steel in concrete structures has been used successfully for over 20 years. CP is able to stop corrosion in a reliable and economical way where chloride contamination has caused reinforcement corrosion and subsequent concrete damage. To new structures where

  20. Development of an Automatic Dispensing System for Traditional Chinese Herbs

    Directory of Open Access Journals (Sweden)

    Chi-Ying Lin

    2017-01-01

    Full Text Available The gathering of ingredients for decoctions of traditional Chinese herbs still relies on manual dispensation, due to the irregular shape of many items and inconsistencies in weights. In this study, we developed an automatic dispensing system for Chinese herbal decoctions with the aim of reducing manpower costs and the risk of mistakes. We employed machine vision in conjunction with a robot manipulator to facilitate the grasping of ingredients. The name and formulation of the decoction are input via a human-computer interface, and the dispensing of multiple medicine packets is performed automatically. An off-line least-squared curve fitting method was used to calculate the amount of material grasped by the claws and thereby improve system efficiency as well as the accuracy of individual dosages. Experiments on the dispensing of actual ingredients demonstrate the feasibility of the proposed system.

  1. Drug dispensing errors in a ward stock system

    DEFF Research Database (Denmark)

    Andersen, Stig Ejdrup

    2010-01-01

    . Multivariable analysis showed that surgical and psychiatric settings were more susceptible to involvement in dispensing errors and that polypharmacy was a risk factor. In this ward stock system, dispensing errors are relatively common, they depend on speciality and are associated with polypharmacy......The aim of this study was to determine the frequency of drug dispensing errors in a traditional ward stock system operated by nurses and to investigate the effect of potential contributing factors. This was a descriptive study conducted in a teaching hospital from January 2005 to June 2007. In five....... These results indicate that strategies to reduce dispensing errors should address polypharmacy and focus on high-risk units. This should, however, be substantiated by a future trial....

  2. Foreign private capital inflows in Nigeria's democratic dispensation ...

    African Journals Online (AJOL)

    FPCI) in Nigeria in the current democratic dispensation with a view to finding out whether the inflows have recorded significant increase since the institution of Democracy in the country. Relevant theories and empirical data were reviewed.

  3. Determinants of Dispensing Location in the TRICARE Senior Pharmacy Program

    Science.gov (United States)

    2005-01-01

    proximity to an MTF on TSRx use and on uti - lization of the different dispensing locations; and the impact of MTF formulary restrictions on use of the...Conclusions and Policy Implications Our analysis of the TSRx program, which focused on describing uti - lization patterns by dispensing location and on...manufacturers do. In the public sector, some Medicaid programs have recently hired physicians and pharmacists to visit doctors’ offices and encourage them to

  4. 46 CFR 105.90-1 - Existing commercial fishing vessels dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Existing commercial fishing vessels dispensing petroleum... AND MISCELLANEOUS VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Existing Commercial Fishing Vessels Dispensing Petroleum Products § 105.90-1 Existing commercial fishing vessels dispensing...

  5. Recent advances in inkjet dispensing technologies: applications in drug discovery.

    Science.gov (United States)

    Zhu, Xiangcheng; Zheng, Qiang; Yang, Hu; Cai, Jin; Huang, Lei; Duan, Yanwen; Xu, Zhinan; Cen, Peilin

    2012-09-01

    Inkjet dispensing technology is a promising fabrication methodology widely applied in drug discovery. The automated programmable characteristics and high-throughput efficiency makes this approach potentially very useful in miniaturizing the design patterns for assays and drug screening. Various custom-made inkjet dispensing systems as well as specialized bio-ink and substrates have been developed and applied to fulfill the increasing demands of basic drug discovery studies. The incorporation of other modern technologies has further exploited the potential of inkjet dispensing technology in drug discovery and development. This paper reviews and discusses the recent developments and practical applications of inkjet dispensing technology in several areas of drug discovery and development including fundamental assays of cells and proteins, microarrays, biosensors, tissue engineering, basic biological and pharmaceutical studies. Progression in a number of areas of research including biomaterials, inkjet mechanical systems and modern analytical techniques as well as the exploration and accumulation of profound biological knowledge has enabled different inkjet dispensing technologies to be developed and adapted for high-throughput pattern fabrication and miniaturization. This in turn presents a great opportunity to propel inkjet dispensing technology into drug discovery.

  6. Nanostructured lanthanum manganate composite cathode

    DEFF Research Database (Denmark)

    Wang, Wei Guo; Liu, Yi-Lin; Barfod, Rasmus

    2005-01-01

    that the (La1-xSrx)(y)MnO3 +/-delta (LSM) composite cathodes consist of a network of homogenously distributed LSM, yttria-stabilized zirconia (YSZ), and pores. The individual grain size of LSM or YSZ is approximately 100 nm. The degree of contact between cathode and electrolyte is 39% on average. (c) 2005...

  7. Electrostatic probe and calorimetric measurements in a DC cathodic arc

    International Nuclear Information System (INIS)

    Lepone, Alejandro; Marquez, Adriana; Kelly, Hector; Grondona, Diana

    2001-01-01

    Several results obtained from measurements with spherical Langmuir probes and a calorimetric technique in a dc cathodic arc are presented. The arc is operated at a current level of 100 A, with a Copper cathode, and with Oxygen gas at a pressure in the range 0.005 divide 0.2 mbar. The measurements were performed at different axial positions in the discharge chamber. It is found that the electron temperature decreases for larger axial positions or higher pressures, but the derivation of reliable values for the ion density and kinetic energy require the consideration of atomic processes between the plasma and gas particles

  8. Effects of pulse-length and emitter area on virtual cathode formation in electron guns

    International Nuclear Information System (INIS)

    Valfells, Agust; Feldman, D.W.; Virgo, M.; O'Shea, P.G.; Lau, Y.Y.

    2002-01-01

    Recent experiments at the University of Maryland using photoemission from a dispenser cathode have yielded some interesting results regarding the effects of the area of emission and of the ratio between the pulse length and the gap transit time on the amount of current that may be drawn from an electron gun before a virtual cathode forms. The experiments show that a much higher current density may be drawn from a short pulse or limited emitter area than is anticipated by the Child-Langmuir limiting current. There is also evidence that the current may be increased even after virtual cathode formation, which leads a distinction between a limiting current density and a current density critical for virtual cathode formation. The experiments have also yielded some interesting results on the longitudinal structure of the current pulse passed through the anode. Some empirical and theoretical scaling laws regarding the formation of virtual cathodes in an electron gun will be presented. This work was motivated by the needs of the University of Maryland Electron Ring (UMER) [P. G. O'Shea, M. Reiser, R. A. Kishek et al., Nucl. Instrum. Methods Phys. Res. A 464, 646 (2001)] where the goal is to generate pulses that are well-localized in time and space

  9. Slow Release of Plant Volatiles Using Sol-Gel Dispensers.

    Science.gov (United States)

    Bian, L; Sun, X L; Cai, X M; Chen, Z M

    2014-12-01

    The black citrus aphid, also known as the tea aphid, (Toxoptera aurantii Boyer) attacks economically important crops, including tea (Camellia sinensis (L.) O. Kuntze). In the current study, silica sol-gel formulations were screened to find one that could carry and release C. sinensis plant volatiles to lure black citrus aphids in a greenhouse. The common plant volatile trans-2-hexen-1-al was used as a model molecule to screen for suitable sol-gel formulations. A zNose (Electronic Sensor Technology, Newbury Park, CA) transportable gas chromatograph was used to continuously monitor the volatile emissions. A sol-gel formulation containing tetramethyl orthosilicate and methyltrimethoxysilane in an 8:2 (vol:vol) ratio was selected to develop a slow-release dispenser. The half-life of trans-2-hexen-1-al in the sol-gel dispenser increased slightly with the volume of this compound in the dispenser. Ten different volatiles were tested in the sol-gel dispenser. Alcohols of 6-10 carbons had the longest half-lives (3.01-3.77 d), while esters of 6-12 carbons had the shortest (1.53-2.28 d). Release of these volatiles from the dispensers could not be detected by the zNose after 16 d (cis-3-hexenyl acetate) to 26 d (3,7-dimethylocta-1,6-dien-3-ol). In greenhouse experiments, trans-2-hexen-1-al and cis-3-hexen-1-ol released from the sol-gel dispensers attracted aphids for ≍17 d, and release of these volatiles could not be detected by the zNose after ≍24 d. The sol-gel dispensers performed adequately for the slow release of plant volatiles to trap aphids in the greenhouse. © 2014 Entomological Society of America.

  10. Electron emission from pseudospark cathodes

    International Nuclear Information System (INIS)

    Anders, A.; Anders, S.; Gundersen, M.A.

    1994-01-01

    The pseudospark cathode has the remarkable property of macroscopically homogeneous electron emission at very high current density (>1 kA/cm 2 ) over a large area (some cm 2 ). The model of electron emission presented here is based on the assumption that the pseudospark microscopically utilizes explosive arc processes, as distinct from earlier models of ''anomalous emission in superdense glow discharges.'' Explosive emission similar to vacuum are cathode spots occurs rapidly when the field strength is sufficiently high. The plasma remains macroscopically homogeneous since the virtual plasma anode adapts to the cathode morphology so that the current is carried by a large number of homogeneously distributed cathode spots which are similar to ''type 1'' and ''type 2'' spots of vacuum arc discharges. The net cathode erosion is greatly reduced relative to ''spark gap-type'' emission. At very high current levels, a transition to highly erosive spot types occurs, and this ''arcing'' leads to a significant reduction in device lifetime. Assuming vacuum-arc-like cathode spots, the observed current density and time constants can be easily explained. The observed cathode erosion rate and pattern, recent fast-camera data, laser-induced fluorescence, and spectroscopic measurements support this approach. A new hypothesis is presented explaining current quenching at relatively low currents. From the point of view of electron emission, the ''superdense glow'' or ''superemissive phase'' of pseudosparks represents an arc and not a glow discharge even if no filamentation or ''arcing'' is observed

  11. Ab initio investigation of barium-scandium-oxygen coatings on tungsten for electron emitting cathodes

    Science.gov (United States)

    Vlahos, Vasilios; Booske, John H.; Morgan, Dane

    2010-02-01

    Microwave, x-ray, and radio-frequency radiation sources require a cathode emitting electrons into vacuum. Thermionic B-type dispenser cathodes consist of BaxOz coatings on tungsten (W), where the surface coatings lower the W work function and enhance electron emission. The new and promising class of scandate cathodes modifies the B-type surface through inclusion of Sc, and their superior emissive properties are also believed to stem from the formation of a low work function surface alloy. In order to better understand these cathode systems, density-functional theory (DFT)-based ab initio modeling is used to explore the stability and work function of BaxScyOz on W(001) monolayer-type surface structures. It is demonstrated how surface depolarization effects can be calculated easily using ab initio calculations and fitted to an analytic depolarization equation. This approach enables the rapid extraction of the complete depolarization curve (work function versus coverage relation) from relatively few DFT calculations, useful for understanding and characterizing the emitting properties of novel cathode materials. It is generally believed that the B-type cathode has some concentration of Ba-O dimers on the W surface, although their structure is not known. Calculations suggest that tilted Ba-O dimers are the stable dimer surface configuration and can explain the observed work function reduction corresponding to various dimer coverages. Tilted Ba-O dimers represent a new surface coating structure not previously proposed for the activated B-type cathode. The thermodynamically stable phase of Ba and O on the W surface was identified to be the Ba0.25O configuration, possessing a significantly lower Φ value than any of the Ba-O dimer configurations investigated. The identification of a more stable Ba0.25O phase implies that if Ba-O dimers cover the surface of emitting B-type cathodes, then a nonequilibrium steady state must dominate the emitting surface. The identification of

  12. The K-1 Active Dispenser for Orbit Transfer

    Science.gov (United States)

    Lai, G.; Cochran, D.; Curtis, R.

    2002-01-01

    Kistler Aerospace Corporation is building the K-1, the world's first fully reusable launch vehicle. The two-stage K- 1 is designed primarily to service the market for low-earth orbit (LEO) missions, due to Kistler's need to recover both stages. For customers requiring payload delivery to high-energy orbits, Kistler can outfit the payload with a K- 1 Active Dispenser (an expendable third stage). The K-1 second stage will deploy the Active Dispenser mated with its payload into a 200 km circular LEO parking orbit. From this orbit, the Active Dispenser would use its own propulsion to place its payload into the final desired drop-off orbit or earth-escape trajectory. This approach allows Kistler to combine the low-cost launch services offered by the reusable two-stage K-1 with the versatility of a restartable, expendable upper stage. Enhanced with an Active Dispenser, the K-1 will be capable of delivering 1,500 kg to a geosynchronous transfer orbit or up to approximately 1,000 kg into a Mars rendezvous trajectory. The list price of a K-1 Active Dispenser launch is 25 million (plus the price of mission unique integration services) significantly less than the price of any launch vehicle service in the world with comparable capability.

  13. Research on an improved explosive emission cathode

    International Nuclear Information System (INIS)

    Liu Guozhi; Sun Jun; Shao Hao; Chen Changhua; Zhang Xiaowei

    2009-01-01

    This paper presents a physical description of the cathode plasma process of an explosive emission cathode (EEC) and experimental results on a type of oil-immersed graphite EEC. It is believed that the generation of a cathode plasma is mainly dependent on the state of the cathode surface, and that adsorbed gases and dielectrics on the cathode surface play a leading role in the formation of the cathode plasma. Based on these ideas, a type of oil-immersed graphite EEC is proposed and fabricated. The experiments indicate that the oil-immersed cathodes have improved emissive properties and longer lifetimes.

  14. Theoretical study of cathode surfaces and high-temperature superconductors

    Science.gov (United States)

    Mueller, Wolfgang

    1995-01-01

    Calculations are presented for the work functions of BaO on W, Os, Pt, and alloys of Re-W, Os-W, and Ir-W that are in excellent agreement with experiment. The observed emission enhancement for alloy relative to tungsten dispenser cathodes is attributed to properties of the substrate crystal structure and explained by the smaller depolarization of the surface dipole on hexagonal as compared to cubic substrates. For Ba and BaO on W(100), the geometry of the adsorbates has been determined by a comparison of inverse photoemission spectra with calculated densities of unoccupied states based on the fully relativistic embedded cluster approach. Results are also discussed for models of scandate cathodes and the electronic structure of oxygen on W(100) at room and elevated temperatures. A detailed comparison is made for the surface electronic structure of the high-temperature superconductor YBa2Cu3O7 as obtained with non-, quasi-, and fully relativistic cluster calculations.

  15. Evaluation of single crystal LaB6 cathodes for use in a high frequency backward wave oscillator tube

    Science.gov (United States)

    Swanson, L. W.; Davis, P. R.; Schwind, G. A.

    1984-01-01

    The results of thermionic emission and evaporation studies of single crystal LaB6 cathodes are given. A comparison between the (100), (210) and (310) crystal planes shows the (310) and (210) planes to possess a work function approx 0.2 eV lower than (100). This translates into a significant increase in current density, J, at a specified temperature. Comparison with a state-of-the-art impregnated dispenser cathode shows that LaB6 (310) is a superior cathode in nearly all respects except operating temperature at j 10 A/sq cm. The 1600 K thermionic and room temperature retarding potential work functions for LaB6 (310) are 2.42 and 2.50 respectively.

  16. Do Pregnant Women Report Use of Dispensed Medications?

    DEFF Research Database (Denmark)

    Olesen, Charlotte; Søndergaard, Charlotte; Thrane, Nana

    2001-01-01

    Surveillance of drug safety in pregnancy often draws on administrative prescription registries. Noncompliance in the use of prescribed medication may be frequent among pregnant women owing to their fear of fetotoxic side effects. To estimate compliance in the use of prescription drugs dispensed...... during pregnancy, we compared prescription data from the North Jutland Prescription Database with information on drug use provided by pregnant women to the Danish National Birth Cohort (DNBC), which is a health interview survey. We used the North Jutland Prescription Database to identify all prescription...... drugs dispensed during pregnancy for the 2,041 women who were enrolled in the DNBC in the County of North Jutland, Denmark. Compliance was defined as the probability of reporting drug use in DNBC after purchasing a dispensed prescription drug. The overall compliance to drugs purchased within 120 days...

  17. Volumetric dispenser for small particles from plural sources

    International Nuclear Information System (INIS)

    Bradley, R.A.; Miller, W.H.; Sease, J.D.

    1975-01-01

    Apparatus is described for rapidly and accurately dispensing measured volumes of small particles from a supply hopper. The apparatus includes an adjustable, vertically oriented measuring tube and orifice member defining the volume to be dispensed, a ball plug valve for selectively closing the bottom end of the orifice member, and a compression valve for selectively closing the top end of the measuring tube. A supply hopper is disposed above and in gravity flow communication with the measuring tube. Properly sequenced opening and closing of the two valves provides accurate volumetric discharge through the ball plug valve. A dispensing system is described wherein several appropriately sized measuring tubes, orifice members, and associated valves are arranged to operate contemporaneously to facilitate blending of different particles

  18. Reliability Engineering

    International Nuclear Information System (INIS)

    Lee, Sang Yong

    1992-07-01

    This book is about reliability engineering, which describes definition and importance of reliability, development of reliability engineering, failure rate and failure probability density function about types of it, CFR and index distribution, IFR and normal distribution and Weibull distribution, maintainability and movability, reliability test and reliability assumption in index distribution type, normal distribution type and Weibull distribution type, reliability sampling test, reliability of system, design of reliability and functionality failure analysis by FTA.

  19. How complete is the information on preadmission psychotropic medications in inpatients with dementia? A comparison of hospital medical records with dispensing data.

    Science.gov (United States)

    Pisa, Federica Edith; Palese, Francesca; Romanese, Federico; Barbone, Fabio; Logroscino, Giancarlo; Riedel, Oliver

    2018-06-05

    Reliable information on preadmission medications is essential for inpatients with dementia, but its quality has hardly been evaluated. We assessed the completeness of information and factors associated with incomplete recording. We compared preadmission medications recorded in hospital electronic medical records (EMRs) with community-pharmacy dispensations in hospitalizations with discharge code for dementia at the University Hospital of Udine, Italy, 2012-2014. We calculated: (a) prevalence of omissions (dispensed medication not recorded in EMRs), additions (medication recorded in EMRs not dispensed), and discrepancies (any omission or addition); (b) multivariable logistic regression odds ratio, with 95% confidence interval (95% CI), of ≥1 omission. Among 2,777 hospitalizations, 86.1% had ≥1 discrepancy for any medication (Kappa 0.10) and 33.4% for psychotropics. When psychotropics were recorded in EMR, antipsychotics were added in 71.9% (antidepressants: 29.2%, antidementia agents: 48.2%); when dispensed, antipsychotics were omitted in 54.4% (antidepressants: 52.7%, antidementia agents: 41.5%). Omissions were 92% and twice more likely in patients taking 5 to 9 and ≥10 medications (vs. 0 to 4), 17% in patients with psychiatric disturbances (vs. none), and 41% with emergency admission (vs. planned). Psychotropics, commonly used in dementia, were often incompletely recorded. To enhance information completeness, both EMRs and dispensations should be used. Copyright © 2018 John Wiley & Sons, Ltd.

  20. Control of microbial contamination in drinking water from microfiltering dispensers by dialysis ultrafilters

    Directory of Open Access Journals (Sweden)

    Bolelli Luca

    2016-12-01

    Full Text Available Tap water filtering devices are widely employed to improve odor and taste of tap water, or to obtain refrigerated or sparkling drinking water. The presence of disinfectants-resistant bacteria in tap water is responsible of the biofilm formation inside tubes and tanks. The consequent contamination of dispensed water is a well-known hygiene problem because of the quite constant presence of potentially pathogenic bacteria likes P. aeruginosa. In this study, we tested the technical feasibility and effectiveness of the addition to different commercial devices of a packaged polysulphone fibers filter. We aimed to find a simple solution to implement the quality of the delivered water. Water contamination levels were determined in a wide selection of microfiltered water dispensers and we selected among them a representative group of 10 devices, new or in use. The packaged ultrafilter was introduced in about half of them, to monitor, when possible, in parallel the contamination levels and flow rate of a couple of identical units, with and without the filter. The placement of the dialysis filters resulted feasible at different positions along the water circuits of the variously designed filtration units. Delivered water resulted completely free from bacteria when the filter was placed exactly at, or very close to, the outlet in spite of the inner surfaces contamination. This performance was not obtained in presence of a more or less long tract of water circuits downstream the ultrafilter: a significant but not complete reduction of the plate count numbers was observed. The filters worked in continue over the whole study period, ten months, showing exactly the same efficiency. Moreover, the flow rate in presence of the filter was quite unaffected. The addition of this kind of filter to already in use water dispensers was technically easy, and its use can be recommended in all cases a simple but reliable water sanitization is requested.

  1. Dispensing of non-prescribed antibiotics in Jordan

    Directory of Open Access Journals (Sweden)

    Almaaytah A

    2015-09-01

    Full Text Available Ammar Almaaytah,1 Tareq L Mukattash,2 Julia Hajaj2 1Department of Pharmaceutical Technology, 2Department of Clinical Pharmacy, Faculty of Pharmacy, Jordan University of Science and Technology, Irbid, Jordan Objective: Current regulations in Jordan state that antibiotics cannot be sold without a medical prescription. This study aimed to assess the percentage of pharmacies that dispense antibiotics without a medical prescription in the Kingdom of Jordan and identify and highlight the extent and seriousness of such practices among Jordanian pharmacies. Methods: A prospective study was performed, and five different clinical scenarios were simulated at pharmacies investigated including sore throat, otitis media, acute sinusitis, diarrhea, and urinary tract infection in childbearing-aged women. Three levels of demand were used to convince the pharmacists to sell an antibiotic. Results: A total of 202 total pharmacies in Jordan were visited in the present study. The majority of pharmacies (74.3% dispensed antibiotics without prescription with three different levels of demand. The percentage of pharmacies dispensing antibiotics without a prescription for the sore throat scenario was 97.6%, followed by urinary tract infection (83.3%, diarrhea (83%, and otitis media (68.4%. The lowest percentage of antibiotic dispensing was for the acute sinusitis simulation at 48.5%. Among the pharmacies that dispensed antibiotics, the pharmacists provided an explanation as the number of times per day the drug should be taken in 95.3% of the cases, explained the duration of treatment in 25.7%, and inquired about allergies prior to the sale of the antibiotic in only 17.3%. Only 52 pharmacies (25.7% refused to dispense any kind of antibiotics, the majority (61.5% of this refusal response came from acute sinusitis cases, while the minority (2.4% came from the sore throat cases. Conclusion: The results of this study demonstrate that antibiotics continue to be dispensed

  2. Construction of a smart medication dispenser with high degree of scalability and remote manageability.

    Science.gov (United States)

    Pak, JuGeon; Park, KeeHyun

    2012-01-01

    We propose a smart medication dispenser having a high degree of scalability and remote manageability. We construct the dispenser to have extensible hardware architecture for achieving scalability, and we install an agent program in it for achieving remote manageability. The dispenser operates as follows: when the real-time clock reaches the predetermined medication time and the user presses the dispense button at that time, the predetermined medication is dispensed from the medication dispensing tray (MDT). In the proposed dispenser, the medication for each patient is stored in an MDT. One smart medication dispenser contains mainly one MDT; however, the dispenser can be extended to include more MDTs in order to support multiple users using one dispenser. For remote management, the proposed dispenser transmits the medication status and the system configurations to the monitoring server. In the case of a specific event such as a shortage of medication, memory overload, software error, or non-adherence, the event is transmitted immediately. All these operations are performed automatically without the intervention of patients, through the agent program installed in the dispenser. Results of implementation and verification show that the proposed dispenser operates normally and performs the management operations from the medication monitoring server suitably.

  3. Construction of a Smart Medication Dispenser with High Degree of Scalability and Remote Manageability

    Directory of Open Access Journals (Sweden)

    JuGeon Pak

    2012-01-01

    Full Text Available We propose a smart medication dispenser having a high degree of scalability and remote manageability. We construct the dispenser to have extensible hardware architecture for achieving scalability, and we install an agent program in it for achieving remote manageability. The dispenser operates as follows: when the real-time clock reaches the predetermined medication time and the user presses the dispense button at that time, the predetermined medication is dispensed from the medication dispensing tray (MDT. In the proposed dispenser, the medication for each patient is stored in an MDT. One smart medication dispenser contains mainly one MDT; however, the dispenser can be extended to include more MDTs in order to support multiple users using one dispenser. For remote management, the proposed dispenser transmits the medication status and the system configurations to the monitoring server. In the case of a specific event such as a shortage of medication, memory overload, software error, or non-adherence, the event is transmitted immediately. All these operations are performed automatically without the intervention of patients, through the agent program installed in the dispenser. Results of implementation and verification show that the proposed dispenser operates normally and performs the management operations from the medication monitoring server suitably.

  4. Functionally Graded Cathodes for Solid Oxide Fuel Cells

    International Nuclear Information System (INIS)

    Lei Yang; Ze Liu; Shizhone Wang; Jaewung Lee; Meilin Liu

    2008-01-01

    The main objective of this DOE project is to demonstrate that the performance and long-term stability of the state-of-the-art LSCF cathode can be enhanced by a catalytically active coating (e.g., LSM or SSC). We have successfully developed a methodology for reliably evaluating the intrinsic surface catalytic properties of cathode materials. One of the key components of the test cell is a dense LSCF film, which will function as the current collector for the electrode material under evaluation to eliminate the effect of ionic and electronic transport. Since it is dense, the effect of geometry would be eliminated as well. From the dependence of the electrode polarization resistance on the thickness of a dense LSCF electrode and on partial pressure of oxygen, we have confirmed that the surface catalytic activity of LSCF limits the performances of LSCF-based cathodes. Further, we have demonstrated, using test cells of different configurations, that the performance of LSCF-based electrodes can be significantly enhanced by infiltration of a thin film of LSM or SSC. In addition, the stability of LSCF-based cathodes was also improved by infiltration of LSM or SSC. While the concept feasibility of the electrode architecture is demonstrated, many details are yet to be determined. For example, it is not clear how the surface morphology, composition, and thickness of the coatings change under operating conditions over time, how these changes influence the electrochemical behavior of the cathodes, and how to control the microscopic details of the coatings in order to optimize the performance. The selection of the catalytic materials as well as the detailed microstructures of the porous LSCF and the catalyst layer may critically impact the performance of the proposed cathodes. Further, other fundamental questions still remain; it is not clear why the degradation rates of LSCF cathodes are relatively high, why a LSM coating improves the stability of LSCF cathodes, which catalysts

  5. Mathematical micro-model of a solid oxide fuel cell composite cathode

    International Nuclear Information System (INIS)

    Kenney, B.; Karan, K.

    2004-01-01

    In a solid oxide fuel cell (SOFC), the cathode processes account for a majority of the overall electrochemical losses. A composite cathode comprising a mixture of ion-conducting electrolyte and electron-conducting electro-catalyst can help minimize cathode losses provided microstructural parameters such as particle-size, composition, and porosity are optimized. The cost of composite cathode research can be greatly reduced by incorporating mathematical models into the development cycle. Incorporated with reliable experimental data, it is possible to conduct a parametric study using a model and the predicted results can be used as guides for component design. Many electrode models treat the cathode process simplistically by considering only the charge-transfer reaction for low overpotentials or the gas-diffusion at high overpotentials. Further, in these models an average property of the cathode internal microstructure is assumed. This paper will outline the development of a 1-dimensional SOFC composite cathode micro-model and the experimental procedures for obtaining accurate parameter estimates. The micro-model considers the details of the cathode microstructure such as porosity, composition and particle-size of the ionic and electronic phases, and their interrelationship to the charge-transfer reaction and mass transport processes. The micro-model will be validated against experimental data to determine its usefulness for performance prediction. (author)

  6. [Dispensing care at the dispensing counter in the conditions of a Czech pharmacy].

    Science.gov (United States)

    Macesková, B; Plevacová, H

    2005-03-01

    Evaluation of 108 cases when the pharmacist found a need to intervene into prescription verified the use of internationally employed system of classification of pharmaceutical interventions in the conditions of the Czech pharmacy of the basic type. The so-called dispensing care at the counter was provided by five participating pharmacists (out of seven working in the pharmacy) for a period of six months. The most frequently identified problems included: inappropriate use of medicaments--overdose, use at unsuitable time (28.7 %), a need to inform the patient (17.6 %), potentially ineffective therapy (12.9 %), drug interactions (7.4 %), suspected and potential undesirable effects of prescribed medicaments (7.4 %), and insufficient compliance (6.5 %). Solution of problems with medicaments was most frequently: a change in dosage (25.9 %), recommendation to consult the physician (24.1 %), and professional counselling on pharmacotherapy (23.1 %). The pharmacotherapeutic group identified as the one most frequently requiring a telephone consultation of the pharmacist and the physician was antibiotics, including antibacterial chemotherapeutic agents.

  7. Feasibility study of a biocompatible pneumatic dispensing system using mouse 3T3-J2 fibroblasts

    Science.gov (United States)

    Lee, Sangmin; Kim, Hojin; Kim, Joonwon

    2017-12-01

    This paper presents results for dispensing living cells using a pneumatic dispensing system to verify the feasibility of using this system to fabricate biomaterials. Living cells (i.e., mouse 3T3-J2 fibroblast) were dispensed with different dispensing pressures in order to evaluate the effect of dispensing process on cell viability and proliferation. Based on the results of a live-dead assay, more than 80% of cell viability has been confirmed which was reasonably similar to that in the control group. Furthermore, measurement of cell metabolic activity after dispensing confirmed that the dispensed cell proliferated at a rate comparable to that of the control group. These results demonstrate that the pneumatic dispensing system is a promising tool for fabrication of biomaterials.

  8. Rational dispensing and use of artemether-lumefantrine during ...

    African Journals Online (AJOL)

    This was a prospective-descriptive study involving visits to 200 private retail pharmacies (using a mystery shopper) and interviewing pregnant women at the municipal public hospitals in Dar es Salaam, ... There is therefore a need for continuing training of drug dispensers regarding antimalarial drugs use in pregnancy.

  9. Dispensing apparatus for use in a cued food delivery task.

    Science.gov (United States)

    Deweese, Menton M; Claiborne, Kimberly N; Ng, Jennifer; Dirba, Danika D; Stewart, Hannah L; Schembre, Susan M; Versace, Francesco

    2015-01-01

    Neurobiological models of obesity postulate that obese individuals have difficulty regulating food intake partly because they attribute excessive salience to stimuli signaling food availability. Typically, human studies that investigate the relationship between brain responses to food-related stimuli and obesity present food cues without subsequent delivery of food. However, in order to identify the brain correlates of cue reactivity, we must record brain responses to food-related cues signaling food availability. Therefore, we have developed a dispensing apparatus for use in a cued-food delivery task in which event-related potentials (ERPs) to food-related images predicting food delivery and images not predicting food delivery can be recorded. Here, we describe a method where:•The experimental apparatus dispenses an edible item (i.e., a chocolate candy) which may or may not be eaten, or a non-edible control item (e.g., a plastic bead).•Deposit boxes are available to store uneaten candies and the non-edible control items.•The dispensing mechanism is capable of recording the exact timestamp when each delivery event occurs (e.g., release from the dispenser, arrival in the receptacle, storage in the deposit box).

  10. Dispensing of vitamin products by retail pharmacies in South Africa ...

    African Journals Online (AJOL)

    Objective: The objective of this study was to analyse the dispensing patterns of vitamins (Anatomical Therapeutic Chemical (ATC) group A11) over a one-year period in a group of community pharmacies in South Africa. Design and setting: A retrospective drug utilisation study was conducted on community pharmacy ...

  11. Dispensing of drugs with and without a prescription from private ...

    African Journals Online (AJOL)

    There is little literature available on dispensing patterns and unsupervised sale of medicines from pharmacies in Tanzania. The present study assessed the patterns of drug acquisition from pharmacies by customers: whether by prescription, recommended by pharmacist, or requested by a customer without a prescription.

  12. Dispensing of vitamin products by retail pharmacies in South Africa ...

    African Journals Online (AJOL)

    Ilse Truter

    Survey) years.7 About 39% of US residents have used at least one multivitamin and ... The ATC Classification system is recommended by the. World Health ... Females in the 30 to 39-year age group were dispensed 21.95% of products ...

  13. Electron emission mechanism of carbon fiber cathode

    International Nuclear Information System (INIS)

    Liu Lie; Li Limin; Wen Jianchun; Wan Hong

    2005-01-01

    Models of electron emission mechanism are established concerning metal and carbon fiber cathodes. Correctness of the electron emission mechanism was proved according to micro-photos and electron scanning photos of cathodes respectively. The experimental results and analysis show that the surface flashover induces the electron emission of carbon fiber cathode and there are electron emission phenomena from the top of the carbon and also from its side surface. In addition, compared with the case of the stainless steel cathode, the plasma expansion velocity for the carbon fiber cathode is slower and the pulse duration of output microwave can be widened by using the carbon fiber cathode. (authors)

  14. 46 CFR 105.05-1 - Commercial fishing vessels dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Commercial fishing vessels dispensing petroleum products... MISCELLANEOUS VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Application § 105.05-1 Commercial fishing vessels dispensing petroleum products. (a) The provisions of this part, with the exception of...

  15. 46 CFR 105.45-1 - Loading or dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Loading or dispensing petroleum products. 105.45-1... VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Special Operating Requirements § 105.45-1 Loading or dispensing petroleum products. (a) A commercial fishing vessel must have aboard a letter of...

  16. Electrolytic production and dispensing of hydrogen

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, C.E.; Kuhn, I.F. Jr. [Directed Technologies, Inc., Arlington, VA (United States)

    1995-09-01

    The fuel cell electric vehicle (FCEV) is undoubtedly the only option that can meet both the California zero emission vehicle (ZEV) standard and the President`s goal of tripling automobile efficiency without sacrificing performance in a standard 5-passenger vehicle. The three major automobile companies are designing and developing FCEVs powered directly by hydrogen under cost-shared contracts with the Department of Energy. Once developed, these vehicles will need a reliable and inexpensive source of hydrogen. Steam reforming of natural gas would produce the least expensive hydrogen, but funding may not be sufficient initially to build both large steam reforming plants and the transportation infrastructure necessary to deliver that hydrogen to geographically scattered FCEV fleets or individual drivers. This analysis evaluates the economic feasibility of using small scale water electrolysis to provide widely dispersed but cost-effective hydrogen for early FCEV demonstrations. We estimate the cost of manufacturing a complete electrolysis system in large quantities, including compression and storage, and show that electrolytic hydrogen could be cost competitive with fully taxed gasoline, using existing residential off-peak electricity rates.

  17. Inkjet metrology: high-accuracy mass measurements of microdroplets produced by a drop-on-demand dispenser.

    Science.gov (United States)

    Verkouteren, R Michael; Verkouteren, Jennifer R

    2009-10-15

    We describe gravimetric methods for measuring the mass of droplets generated by a drop-on-demand (DOD) microdispenser. Droplets are deposited, either continuously at a known frequency or as a burst of known number, into a cylinder positioned on a submicrogram balance. Mass measurements are acquired precisely by computer, and results are corrected for evaporation. Capabilities are demonstrated using isobutyl alcohol droplets. For ejection rates greater than 100 Hz, the repeatability of droplet mass measurements was 0.2%, while the combined relative standard uncertainty (u(c)) was 0.9%. When bursts of droplets were dispensed, the limit of quantitation was 72 microg (1490 droplets) with u(c) = 1.0%. Individual droplet size in a burst was evaluated by high-speed videography. Diameters were consistent from the tenth droplet onward, and the mass of an individual droplet was best estimated by the average droplet mass with a combined uncertainty of about 1%. Diameters of the first several droplets were anomalous, but their contribution was accounted for when dispensing bursts. Above the limits of quantitation, the gravimetric methods provided statistically equivalent results and permit detailed study of operational factors that influence droplet mass during dispensing, including the development of reliable microassays and standard materials using DOD technologies.

  18. Plasma Deposition of Oxide-Coated Cathodes

    National Research Council Canada - National Science Library

    Umstattd, Ryan

    1998-01-01

    ...; such cathodes may also have applicability for lower current density continuous wave devices. This novel approach to manufacturing an oxide cathode eliminates the binders that may subsequently (and unpredictably...

  19. Mechanistic Enhancement of SOFC Cathode Durability

    Energy Technology Data Exchange (ETDEWEB)

    Wachsman, Eric [Univ. of Maryland, College Park, MD (United States)

    2016-02-01

    Durability of solid oxide fuel cells (SOFC) under “real world” conditions is an issue for commercial deployment. In particular cathode exposure to moisture, CO2, Cr vapor (from interconnects and BOP), and particulates results in long-term performance degradation issues. Here, we have conducted a multi-faceted fundamental investigation of the effect of these contaminants on cathode performance degradation mechanisms in order to establish cathode composition/structures and operational conditions to enhance cathode durability.

  20. All dispenser printed flexible 3D structured thermoelectric generators

    Science.gov (United States)

    Cao, Z.; Shi, J. J.; Torah, R. N.; Tudor, M. J.; Beeby, S. P.

    2015-12-01

    This work presents a vertically fabricated 3D thermoelectric generator (TEG) by dispenser printing on flexible polyimide substrate. This direct-write technology only involves printing of electrodes, thermoelectric active materials and structure material, which needs no masks to transfer the patterns onto the substrate. The dimension for single thermoelectric element is 2 mm × 2 mm × 0.5 mm while the distance between adjacent cubes is 1.2 mm. The polymer structure layer was used to support the electrodes which are printed to connect the top ends of the thermoelectric material and ensure the flexibility as well. The advantages and the limitations of the dispenser printed 3D TEGs will also be evaluated in this paper. The proposed method is potential to be a low-cost and scalable fabrication solution for TEGs.

  1. Impact of Robotic Dispensing Machines in German Pharmacies on ...

    African Journals Online (AJOL)

    As a result of using a robotic dispensing machine, personnel costs were reduced by an average of 4.6% during the first 12 months after start-up. Over-the-counter sales increased in the same period by an average of 6.8%. Despite average initial costs of 118,000 euros, total costs within the first 12 months fell in 50% of cases ...

  2. [Design and piloting of a structured service medication dispensing process].

    Science.gov (United States)

    Abaurre, Raquel; García-Delgado, Pilar; Maurandi, M Dolores; Arrebola, Cristóbal; Gastelurrutia, Miguel Ángel; Martínez-Martínez, Fernando

    2015-01-01

    The aim of this article is to design and pilot a protocol for the dispensing of medications service. Using the requirements proposed in the Ministry of Health Pharmaceutical Care Consensus, a literature search was made applying qualitative consensus techniques. An observational, cross-sectional study was conducted from March to June 2009. A total of 53 community pharmacies from 24 Spanish counties. Patients who requested one or more particular medications with or without medical prescription for their own use or for someone in their care. The personalised medication information (IPM), the problems associated with the medications (PRM), and the negative results associated with the medication (RNM), detected by the pharmacist each time medication was dispensed, as well as the perception of the pharmacist on the operability of the protocol were recorded. A total of 870 medications were dispensed, with 423 (48.6%) cases of lack of personalised medication information (IPM) being detected. PRM were detected in 10.11% of the dispensed medications, as well as 68 (7.81%) suspected RNM: safety (n = 35; 51.5%), effectiveness (n = 29; 42.6%) and necessity (n = 4; 5.8%). Almost two-thirds (65.21%) of the pharmacists said that the protocol is in operation. The designed protocol helped to detect deficiencies in the information to the patients about their medications, as well as the PRM and RNM, and is shown to be tool that is easy to use and apply. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  3. Dispensing with conscience: a legal and ethical assessment.

    Science.gov (United States)

    Wernow, Jerome R; Grant, Donald G

    2008-11-01

    For over 30 years, pharmacists have exercised the right to dispense medications in accordance with moral convictions based upon a Judeo-Christian ethic. What many of these practitioners see as an apparent shift away from this time-honored ethic has resulted in a challenge to this right. To review and analyze pharmacy practice standards, legal proceedings, and ethical principles behind conflicts of conscientious objection in dispensing drugs used for emergency contraception. We first searched the terms conscience and clause and Plan B and contraception and abortion using Google, Yahoo, and Microsoft Networks (2006-September 26, 2008). Second, we used Medscape to search professional pharmacy and other medical journals, restricting our terms to conscience, Plan B, contraceptives, and abortifacients. Finally, we employed Loislaw, an online legal archiving service, and did a global search on the phrase conscience clause to determine the status of the legal discussion. To date, conflicts in conscientious objection have arisen when a pharmacist believes that dispensing an oral contraceptive violates his or her moral understanding for the promotion of human life. Up to this time, cases in pharmacy have involved only practitioners from orthodox Christian faith communities, primarily devout Roman Catholics. A pharmacist's right to refuse the dispensing of abortifacients for birth control according to moral conscience over against a woman's right to reproductive birth control has created a conflict that has yet to be reconciled by licensing agents, professional standards, or courts of law. Our analysis of prominent conflicts suggests that the underlying worldviews between factions make compromise improbable. Risks and liabilities are dependent upon compliance with evolving state laws, specific disclosure of a pharmacist's moral objections, and professionalism in the handling of volatile situations. Objecting pharmacists and their employers should have clear policies and

  4. Implementation and evaluation of an automated dispensing system.

    Science.gov (United States)

    Schwarz, H O; Brodowy, B A

    1995-04-15

    An institution's experience in replacing a traditional unit dose cassette-exchange system with an automated dispensing system is described. A 24-hour unit dose cassette-exchange system was replaced with an automated dispensing system (Pyxis's Medstation Rx) on a 36-bed cardiovascular surgery unit and an 8-bed cardiovascular intensive care unit. Significantly fewer missing doses were reported after Medstation Rx was implemented. No conclusions could be made about the impact of the system on the reporting of medication errors. The time savings for pharmacy associated with the filling, checking, and delivery of new medication orders equated to about 0.5 full-time equivalent (FTE). Medstation Rx also saved substantial nursing time for acquisition of controlled substances and for controlled-substance inventory taking at shift changes. A financial analysis showed that Medstation Rx could save the institution about $1 million over five years if all personnel time savings could be translated into FTE reductions. The automated system was given high marks by the nurses in a survey; 80% wanted to keep the system on their unit. Pilot implementation of an automated dispensing system improved the efficiency of drug distribution over that of the traditional unit dose cassette-exchange system.

  5. A randomized controlled trial with a Canadian electronic pill dispenser used to measure and improve medication adherence in patients with schizophrenia

    OpenAIRE

    Stip, Emmanuel; Vincent, Philippe D.; Sablier, Juliette; Guevremont, Catherine; Zhornitsky, Simon; Tranulis, Constantin

    2013-01-01

    Objective: Medication adherence is extremely important in preventing relapse and lowering symptoms in schizophrenic patients. However, estimates show that nearly half of these patients have poor adherence. The Brief Adherence Rating Scale (BARS) seems to be the most reliable tool assessing adherence in schizophrenia and shows that the antipsychotic adherence ratio (AAR) is about 49.5% in schizophrenia. The aim of the study was to test if an electronic pill dispenser named DoPill® improved AAR...

  6. A randomized-controlled trial with a Canadian electronic pill dispenser used to measure and improve medication adherence in patients with schizophrenia

    OpenAIRE

    Emmanuel eStip; Emmanuel eStip; Emmanuel eStip; Philippe D. Vincent; Philippe D. Vincent; Philippe D. Vincent; Catherine eGuevremont; Simon eZhornitsky; Constantin eTranulis; Constantin eTranulis; Constantin eTranulis; Juliette eSablier; Juliette eSablier

    2013-01-01

    Objective: Medication adherence is extremely important in preventing relapse and lowering symptoms in schizophrenic patients. However, estimates show that nearly half of these patients have poor adherence. The Brief Adherence Rating Scale (BARS) seems to be the most reliable tool assessing adherence in schizophrenia and shows that the antipsychotic adherence ratio (AAR) is about 49.5 % in schizophrenia. The aim of the study was to test if an electronic pill dispenser named DoPill® improv...

  7. Synopsis of Cathode No.4 Activation

    International Nuclear Information System (INIS)

    Kwan, Joe; Ekdahl, C.; Harrison, J.; Kwan, J.; Leitner, M.; McCruistian, T.; Mitchell, R.; Prichard, B.; Roy, P.

    2006-01-01

    The purpose of this report is to describe the activation of the fourth cathode installed in the DARHT-II Injector. Appendices have been used so that an extensive amount of data could be included without danger of obscuring important information contained in the body of the report. The cathode was a 612 M type cathode purchased from Spectra-Mat. Section II describes the handling and installation of the cathode. Section III is a narrative of the activation based on information located in the Control Room Log Book supplemented with time plots of pertinent operating parameters. Activation of the cathode was performed in accordance with the procedure listed in Appendix A. The following sections provide more details on the total pressure and constituent partial pressures in the vacuum vessel, cathode heater power/filament current, and cathode temperature

  8. LOW TEMPERATURE CATHODE SUPPORTED ELECTROLYTES

    Energy Technology Data Exchange (ETDEWEB)

    Harlan U. Anderson; Fatih Dogan; Vladimir Petrovsky

    2002-03-31

    This project has three main goals: Thin Films Studies, Preparation of Graded Porous Substrates and Basic Electrical Characterization and testing of Planar Single Cells. This period has continued to address the problem of making dense 1/2 to 5 {micro}m thick dense layers on porous substrates (the cathode LSM). Our current status is that we are making structures of 2-5 cm{sup 2} in area, which consist of either dense YSZ or CGO infiltrated into a 2-5 {micro}m thick 50% porous layer made of either nanoncrystalline CGO or YSZ powder. This composite structure coats a macroporous cathode or anode; which serves as the structural element of the bi-layer structure. These structures are being tested as SOFC elements. A number of structures have been evaluated both as symmetrical and as button cell configuration. Results of this testing indicates that the cathodes contribute the most to cell losses for temperatures below 750 C. In this investigation different cathode materials were studied using impedance spectroscopy of symmetric cells and IV characteristics of anode supported fuel cells. Cathode materials studied included La{sub 0.8}Sr{sub 0.2}Co{sub 0.2}Fe{sub 0.8}O{sub 3} (LSCF), La{sub 0.7}Sr{sub 0.2}MnO{sub 3} (LSM), Pr{sub 0.8}Sr{sub 0.2}Fe{sub 0.8}O{sub 3} (PSCF), Sm{sub 0.8}Sr{sub 0.2}Co{sub 0.2}Fe{sub 0.8}O{sub 3} (SSCF), and Yb{sub .8}Sr{sub 0.2}Co{sub 0.2}Fe{sub 0.8}O{sub 3} (SSCF). A new technique for filtering the Fourier transform of impedance data was used to increase the sensitivity of impedance analysis. By creating a filter specifically for impedance spectroscopy the resolution was increased. The filter was tailored to look for specific circuit elements like R//C, Warburg, or constant phase elements. As many as four peaks can be resolved using the filtering technique on symmetric cells. It may be possible to relate the different peaks to material parameters, like the oxygen exchange coefficient. The cathode grouped in order from lowest to highest ASR is

  9. Evaluating the Impact of Drug Dispensing Systems on the Safety and Efficiency in a Singapore Outpatient Pharmacy

    Directory of Open Access Journals (Sweden)

    Peter Ong Yong Sheng

    2014-01-01

    Full Text Available Purpose: Automation of pharmacy workflow can reduce medication errors as well as improve efficiency of the medication picking, packing and labeling process. Since September 2012, two drug dispensing systems (DDS began operations in the Singapore General Hospital Specialist Outpatient Clinic Pharmacy. This study sought to evaluate the impact of the DDS on safety and efficiency in the pharmacy. Methods: The primary outcome was the rate of prevented dispensing incidents contributed by DDS or manual picking of medications defined as the number of prevented dispensing incidents per 1000 medications picked. The secondary outcome was the productivity of each full time equivalent (FTE when assigned to either the DDS or manual picking stations. Data pertaining to the primary and secondary outcomes between January and December 2013 were collected and analyzed. The rate of prevented dispensing incidents was expressed in median (interquartile range and compared using Mann-Whitney U test. Other continuous variables were expressed in mean ± standard deviation and compared using independent samples t-test. Results: An average of 59494 medications was picked every month in the pharmacy. DDS accounted for 21.1 percent while manual picking accounted for 78.9 percent of all the medications picked. The median rate of prevented dispensing incidents per month committed by manual picking (2.73 was significantly higher than the DDS (0.00. DDS had greater productivity with each FTE in the DDS having an average of 6175 picks per month which was significantly higher than each FTE in the manual picking stations which had an average of 4867 picks per month. Conclusion: Installation of DDS in an outpatient pharmacy improved safety of the pharmacy workflow by automating the medication picking, packing and labeling process and minimizing human errors. Efficiency of the medication picking, packing and labeling process was also improved by the DDS as there were continuous

  10. Software reliability

    CERN Document Server

    Bendell, A

    1986-01-01

    Software Reliability reviews some fundamental issues of software reliability as well as the techniques, models, and metrics used to predict the reliability of software. Topics covered include fault avoidance, fault removal, and fault tolerance, along with statistical methods for the objective assessment of predictive accuracy. Development cost models and life-cycle cost models are also discussed. This book is divided into eight sections and begins with a chapter on adaptive modeling used to predict software reliability, followed by a discussion on failure rate in software reliability growth mo

  11. A frequency conversion mode for dispenser in the service station based on flow rate signal

    International Nuclear Information System (INIS)

    Liu, Y J; Tang, D; Huang, J B; Liu, J; Jia, P F

    2012-01-01

    Dispenser is an integrated fuel transport and measurement system at the service station. In this paper, we developed a frequency conversion mode for the dispenser, based on the flow rate signal which is obtained from the converter measuring flow capacity. After introducing the frequency conversion mode to dispenser, we obtained that pump rotates at a high speed when fuelled with high flow rate, and it rotates at a low speed when fuelled with low flow rate. This makes the fuel dispenser more energy-efficient and controllable. We also did some valve optimizations on the dispenser and developed a new control mode for preset refuelling based on the frequency conversion mode, Experimental and theoretical studies have shown that the new dispenser not only can meet the national standards, but also performs better than the ordinary one especially in preset refuelling.

  12. A Curriculum For Dispensing Optician A Case Study In Vietnam

    Directory of Open Access Journals (Sweden)

    Duong Dieu MD

    2015-08-01

    Full Text Available Until 2011 there had been no full-time training course for dispensing optician diploma in Vietnam. Most of the practicing opticians with no qualification and formal training have learnt their skills through apprentice. In response to the demand of the industry Nguyen Tat Thanh University Vietnam has teamed up with Bradford College United Kingdom to develop a curriculum for a of formal 2-year full-time training for dispensing optician. The curriculum is applied for 4 semesters and graduate gets called Intermediate Professional Diploma level included 4 semesters. In VN after high school students can obtain different many levels of study such as Intermediate Professional Diploma College Bachelor Master and PhD. The 1st semester is basis of Intermediate Professional Diploma level. The 2nd semester is the study of refractive error and primary care each for 4 weeks 100 hours in theory and primary eye care 4 weeks for theory 100 hours. Also in this semester the learners have practiced clinical rotation at the Ophthalmic Hospital Ophthalmic Service in General Hospital for 10 weeks. The 3rd semester is specialized of dispensing Optician included Lenses frame contact lenses and laboratory for optician. In the 4th semester the training concentrates in the management of the eyeglasses shop and practicing in making spectacles for customers are in the 4th semester. The 1st intake of the course was opened started in 2011 and had 30 students graduated in 2013. This paper describes the experience of developing the curriculum in the context of a developing country where the industry is still under regulated and less developed. The first program optician that privileged on primary eye care will be satisfied for community WHO 2020 1 optometrist for 50.000 people and 10 ophthalmologists for 1.000.000 people. Some characteristics of first course students have been noted. The result of this curriculum will be evaluated in the coming time.

  13. Impact of an automated dispensing system in outpatient pharmacies.

    Science.gov (United States)

    Humphries, Tammy L; Delate, Thomas; Helling, Dennis K; Richardson, Bruce

    2008-01-01

    To evaluate the impact of an automated dispensing system (ADS) on pharmacy staff work activities and job satisfaction. Cross-sectional, retrospective study. Kaiser Permanente Colorado (KPCO) outpatient pharmacies in September 2005. Pharmacists and technicians from 18 outpatient pharmacies. All KPCO outpatient pharmacists (n = 136) and technicians (n = 160) were surveyed regarding demographics and work activities and pharmacist job satisfaction. Work activities and job satisfaction were compared between pharmacies with and without ADS. Historical prescription purchase records from ADS pharmacies were assessed for pre-ADS to post-ADS changes in productivity. Self-reported pharmacy staff work activities and pharmacist job satisfaction. Pharmacists who responded to the demographic questionnaire (n = 74) were primarily women (60%), had a bachelor's degree in pharmacy (68%), and had been in practice for 10 years or more (53%). Responding technicians (n = 72) were predominantly women (80%) with no postsecondary degree (90%) and fewer than 10 years (68%) in practice. Pharmacists in ADS pharmacies who responded to the work activities questionnaire (n = 50) reported equivalent mean hours spent in patient care activities and filling medication orders compared with non-ADS pharmacists (n = 33; P > 0.05). Similarly, technicians in ADS pharmacies who responded to the work activities questionnaire (n = 64) reported equivalent mean hours spent in filling medication orders compared with non-ADS technicians (n = 38; P > 0.05). An equivalent proportion of ADS pharmacists reported satisfaction with their current job compared with non-ADS pharmacies (P > 0.05). Mean productivity did not increase appreciably after automation (P >0.05). By itself, installing an ADS does not appear to shift pharmacist work activities from dispensing to patient counseling or to increase job satisfaction. Shifting pharmacist work activities from dispensing to counseling and monitoring drug therapy outcomes

  14. Guide to Permitting Hydrogen Motor Fuel Dispensing Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Rivkin, Carl [National Renewable Energy Lab. (NREL), Golden, CO (United States); Buttner, William [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burgess, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-03-28

    The purpose of this guide is to assist project developers, permitting officials, code enforcement officials, and other parties involved in developing permit applications and approving the implementation of hydrogen motor fuel dispensing facilities. The guide facilitates the identification of the elements to be addressed in the permitting of a project as it progresses through the approval process; the specific requirements associated with those elements; and the applicable (or potentially applicable) codes and standards by which to determine whether the specific requirements have been met. The guide attempts to identify all applicable codes and standards relevant to the permitting requirements.

  15. Dicer is dispensable for asymmetric RISC loading in mammals.

    Science.gov (United States)

    Betancur, Juan G; Tomari, Yukihide

    2012-01-01

    In flies, asymmetric loading of small RNA duplexes into Argonaute2-containing RNA-induced silencing complex (Ago2-RISC) requires Dicer-2/R2D2 heterodimer, which acts as a protein sensor for the thermodynamic stabilities of the ends of small RNA duplexes. However, the mechanism of small RNA asymmetry sensing in mammalian RISC assembly remains obscure. Here, we quantitatively examined RISC assembly and target silencing activity in the presence or absence of Dicer in mammals. Our data show that, unlike the well-characterized fly Ago2-RISC assembly pathway, mammalian Dicer is dispensable for asymmetric RISC loading in vivo and in vitro.

  16. The impact of automation on workload and dispensing errors in a hospital pharmacy.

    Science.gov (United States)

    James, K Lynette; Barlow, Dave; Bithell, Anne; Hiom, Sarah; Lord, Sue; Pollard, Mike; Roberts, Dave; Way, Cheryl; Whittlesea, Cate

    2013-04-01

    To determine the effect of installing an original-pack automated dispensing system (ADS) on dispensary workload and prevented dispensing incidents in a hospital pharmacy. Data on dispensary workload and prevented dispensing incidents, defined as dispensing errors detected and reported before medication had left the pharmacy, were collected over 6 weeks at a National Health Service hospital in Wales before and after the installation of an ADS. Workload was measured by non-participant observation using the event recording technique. Prevented dispensing incidents were self-reported by pharmacy staff on standardised forms. Median workloads (measured as items dispensed/person/hour) were compared using Mann-Whitney U tests and rate of prevented dispensing incidents were compared using Chi-square test. Spearman's rank correlation was used to examine the association between workload and prevented dispensing incidents. A P value of ≤0.05 was considered statistically significant. Median dispensary workload was significantly lower pre-automation (9.20 items/person/h) compared to post-automation (13.17 items/person/h, P automation (0.28%) than pre-automation (0.64%, P automation (ρ = 0.23, P automation improves dispensing efficiency and reduces the rate of prevented dispensing incidents. It is proposed that prevented dispensing incidents frequently occurred during periods of high workload due to involuntary automaticity. Prevented dispensing incidents occurring after a busy period were attributed to staff experiencing fatigue after-effects. © 2012 The Authors. IJPP © 2012 Royal Pharmaceutical Society.

  17. Regulations, Codes, and Standards (RCS) Template for California Hydrogen Dispensing Stations

    Energy Technology Data Exchange (ETDEWEB)

    Rivkin, C.; Blake, C.; Burgess, R.; Buttner, W.; Post, M.

    2012-11-01

    This report explains the Regulations, Codes, and Standards (RCS) requirements for hydrogen dispensing stations in the State of California. The reports shows the basic components of a hydrogen dispensing station in a simple schematic drawing; the permits and approvals that would typically be required for the construction and operation of a hydrogen dispensing station; and a basic permit that might be employed by an Authority Having Jurisdiction (AHJ).

  18. Electron beam generation form a superemissive cathode

    International Nuclear Information System (INIS)

    Hsu, T.-Y.; Liou, R.-L.; Kirkman-Amemiya, G.; Gundersen, M.A.

    1991-01-01

    An experimental study of electron beams produced by a superemissive cathode in the Back-Lighted Thyratron (BLT) and the pseudospark is presented. This work is motivated by experiments demonstrating very high current densities (≥10 kA/cm 2 over an area of 1 cm 2 ) from the pseudospark and BLT cathode. This high-density current is produced by field-enhanced thermionic emission from the ion beam-heated surface of a molybdenum cathode. This work reports the use of this cathode as a beam source, and is to be distinguished from previous work reporting hollow cathode-produced electron beams. An electron beam of more than 260 A Peak current has been produced with 15 kV applied voltage. An efficiency of ∼10% is estimated. These experimental results encourage further investigation of the super-emissive cathode as an intense electron beam source for applications including accelerator technology

  19. Reflective article having a sacrificial cathodic layer

    Science.gov (United States)

    Kabagambe, Benjamin; Buchanan, Michael J.; Scott, Matthew S.; Rearick, Brian K.; Medwick, Paul A.; McCamy, James W.

    2017-09-12

    The present invention relates to reflective articles, such as solar mirrors, that include a sacrificial cathodic layer. The reflective article, more particularly includes a substrate, such as glass, having a multi-layered coating thereon that includes a lead-free sacrificial cathodic layer. The sacrificial cathodic layer includes at least one transition metal, such as a particulate transition metal, which can be in the form of flakes (e.g., zinc flakes). The sacrificial cathodic layer can include an inorganic matrix formed from one or more organo-titanates. Alternatively, the sacrificial cathodic layer can include an organic polymer matrix (e.g., a crosslinked organic polymer matrix formed from an organic polymer and an aminoplast crosslinking agent). The reflective article also includes an outer organic polymer coating, that can be electrodeposited over the sacrificial cathodic layer.

  20. The 340B discount program: outpatient prescription dispensing patterns through contract pharmacies in 2012.

    Science.gov (United States)

    Clark, Bobby L; Hou, John; Chou, Chia-Hung; Huang, Elbert S; Conti, Rena

    2014-11-01

    Section 340B of the Public Health Service Act provides qualified organizations serving vulnerable populations with deep discounts for some outpatient medications. A 2010 regulatory change widely expanded the 340B program's reach, allowing these organizations to contract with retail pharmacies to dispense medications for eligible patients. Little is known about which medications are dispensed by contract pharmacies under the expanded program. We provide the first comparison of 340B prescriptions and all prescriptions dispensed in contract pharmacies. We used 2012 data from Walgreens, the national leader in 340B contract pharmacies. Medications used to treat chronic conditions such as diabetes, high cholesterol levels, asthma, and depression accounted for an overwhelming majority of all prescriptions dispensed at Walgreens as part of the 340B program. A higher percentage of antiretrovirals used to treat HIV/AIDS were dispensed through 340B prescriptions than through all prescriptions dispensed at Walgreens. The majority of 340B prescriptions dispensed at Walgreens originated at tuberculosis clinics, consolidated health centers, disproportionate-share hospitals, and Ryan White clinics. Our results suggest that 340B contract pharmacies dispense medications used to treat Americans' chronic disease burden and disproportionately dispense medications used by key vulnerable populations targeted by the program. Project HOPE—The People-to-People Health Foundation, Inc.

  1. Preventing Corrosion by Controlling Cathodic Reaction Kinetics

    Science.gov (United States)

    2016-03-25

    3. DATES COVERED (From - To) 09/23/15 - 04/22/16 4. TITLE AND SUBTITLE Sa. CONTRACT NUMBER Preventing Corrosion by Controlling Cathodic Reaction...Preventing corrosion by controlling cathodic reaction kinetics Progress Report for Period: 1 SEP 2015-31 MAR 2016 John Keith Department of...25 March 2016 Preventing corrosion by controlling cathodic reaction kinetics Annual Summary Report: FY16 PI: John Keith, 412-624-7016,jakeith

  2. Hollow cathode for positive ion sources

    International Nuclear Information System (INIS)

    Schechter, D.E.; Kim, J.; Tsai, C.C.

    1979-01-01

    Development to incorporate hollow cathodes into high power ion sources for neutral beam injection systems is being pursued. Hollow tube LaB 6 -type cathodes, similar to a UCLA design, have been constructed and tested in several ORNL ion source configurations. Results of testing include arc discharge parameters of >1000 and 500 amps for 0.5 and 10 second pulse lengths, respectively. Details of cathode construction and additional performance results are discussed

  3. Human reliability

    International Nuclear Information System (INIS)

    Embrey, D.E.

    1987-01-01

    Concepts and techniques of human reliability have been developed and are used mostly in probabilistic risk assessment. For this, the major application of human reliability assessment has been to identify the human errors which have a significant effect on the overall safety of the system and to quantify the probability of their occurrence. Some of the major issues within human reliability studies are reviewed and it is shown how these are applied to the assessment of human failures in systems. This is done under the following headings; models of human performance used in human reliability assessment, the nature of human error, classification of errors in man-machine systems, practical aspects, human reliability modelling in complex situations, quantification and examination of human reliability, judgement based approaches, holistic techniques and decision analytic approaches. (UK)

  4. Reliability Calculations

    DEFF Research Database (Denmark)

    Petersen, Kurt Erling

    1986-01-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety...... and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic...... approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very...

  5. Cold cathode arc model in mercury discharges

    International Nuclear Information System (INIS)

    Li, Y.M.; Byszewski, W.W.; Budinger, A.B.

    1990-01-01

    Voltage/current characteristics measured during the starting of metal halide lamps indicate a low voltage discharge when condensates (mainly mercury) are localized on the electrodes. In this case, even with a cold cathode which does not emit electrons, the current is very high and voltage across the lamp drops to about 15 to 20 V. This type of discharge is similar to the cold cathode mercury vapor arc found in mercury pool rectifiers. The cathode sheath in the mercury vapor arc is characterized by very small cathode spot size, on the order of 10 -c cm 2 , very high current density of about 10 6 A/cm 2 and very low cathode fall of approximately 10 volts. The discharge is modified and generalized to describe the cathode phenomena in the cold cathode mercury vapor arc. The sensitivity of calculated discharge parameters with respect to such modifications were examined. Results show that the cathode fall voltage remains fairly constant (7-8 volts) with large fractional variations of metastable mercury atoms bombarding the cathode. This result compares very well with experimental waveforms when anode fall and plasma voltage approximations are incorporated

  6. Two-beam virtual cathode accelerator

    International Nuclear Information System (INIS)

    Peter, W.

    1992-01-01

    A proposed method to control the motion of a virtual cathode is investigated. Applications to collective ion acceleration and microwave generation are indicated. If two counterstreaming relativistic electron beams of current I are injected into a drift tube of space-charge-limiting current I L = 2I, it is shown that one beam can induce a moving virtual cathode in the other beam. By dynamically varying the current injected into the drift tube region, the virtual cathode can undergo controlled motion. For short drift tubes, the virtual cathodes on each end are strongly-coupled and undergo coherent large-amplitude spatial oscillations within the drift tube

  7. PROJECT OF COAGULANT DISPENSER IN PULVERIZATION AERATOR WITH WIND DRIVE

    Directory of Open Access Journals (Sweden)

    Ewa Osuch

    2017-09-01

    Full Text Available Lakes are one of most important freshwater ecosystems, playing significant role in functioning of nature and human economy. Swarzędzkie Lake is good example of ecosystem, which in last half-century was exposed to the influence of strong anthropopressure. Direct inflow of sewage with large number of biogens coming to the lake with water of inflows caused distinct disturbance of its functioning. In autumn 2011 restoration begined on Swarzędzkie Lake for reduction of lake trophy and improvement of water quality. For achieving better and quicker effect, simultaneously combination of some methods was applied, among others method of oxygenation of over-bottom water with help of pulverization aerator and method of precise inactivation of phosphorus in water depths. Characterization and analysis of improved coagulant dispenser applying active substance only during work of pulverization aerator is the aim of this thesis. Principle of dispenser work, its structure and location in pulverization aerator were explained. It was stated, that introduction to water a factor initiating process of phosphorus inactivation causes significant reduction of mineral phosphorus in water and size of coagulant dose correlates with intensity of work of pulverization aerator with wind drive.

  8. Trends in radiopharmaceutical dispensing in a regional nuclear pharmacy

    International Nuclear Information System (INIS)

    Basmadjian, G.P.; Barker, K.; Johnston, J.; Stinchcomb, R.; Tarman, B.; Ice, R.D.

    1983-01-01

    In the last five years, the practice of nuclear medicine has undergone changes due to the advent of new imaging technologies and radiopharmaceuticals. These changes have had an impact upon the number and the type of radiopharmaceuticals dispensed in centralized nuclear pharmacies. With the advent of Computerized Axial Tomography Scanners (CAT), sophistication and wider acceptance of the Ultrasound imaging modality, nuclear medicine has had to change directions from utilizing radiopharmaceuticals for static organ imaging to functional type imaging and to resort to the use of new radiopharmaceuticals or to find other uses for the existing radiopharmaceuticals. The following trends in radiopharmaceutical dispensing in a regional nuclear pharmacy are evident: Brain procedures have declined by about 67% while nuclear cardiology studies have increased by over 2000%. Bone scans have increased by 72% while liver, renal and lung studies have shown no significant increase. These changes will continue as the practice of nuclear medicine concentrates more on functional studies and relegates other studies to newer imaging modalities

  9. Cathode materials: A personal perspective

    Energy Technology Data Exchange (ETDEWEB)

    Goodenough, John B. [Texas Materials Institute, University of Texas at Austin, ETC 9.102, 1 University Station, Austin, TX 78712-1063 (United States)

    2007-12-06

    A thermodynamically stable rechargeable battery has a voltage limited by the window of the electrolyte. An aqueous electrolyte has a window of 1.2 eV, which prevents achieving the high energy density desired for many applications. A non-aqueous electrolyte with a window of 5 eV requires Li{sup +} rather than H{sup +} as the working ion. Early experiments with Li{sub x}TiS{sub 2} cathodes showed competitive capacity and rate capability, but problems with a lithium anode made the voltage of a safe cell based on a sulfide cathode too low to be competitive with a nickel/metal-hydride battery. Transition-metal oxides can give voltages of 4.5 V versus Li{sup +}/Li{sup 0}. However, the challenge with oxides has been to obtain a competitive capacity and rate capability while retaining a high voltage with low-cost, environmentally friendly cathode materials. Comparisons will be made between layered Li{sub 1-x}MO{sub 2}, spinels Li{sub 1-x}[M{sub 2}]O{sub 4}, and olivines Li{sub 1-x}MPO{sub 4} having 0 < x < 1. Although higher capacities can be obtained with layered Li{sub 1-x}MO{sub 2} compounds, which have enabled the wireless revolution, their metastability makes them unlikely to be used in power applications. The spinel and olivine framework structures have been shown to be capable of charge/discharge rates of over 10C with a suitable temperature range for plug-in hybrid vehicles. (author)

  10. The challenge of responsible dispensing: formal education versus professional practice

    Directory of Open Access Journals (Sweden)

    Nadine Judith Bezzegh

    2011-03-01

    Full Text Available The aim of the present study was to evaluate the education of Pharmaceutical Technicians for the activity of responsible dispensing. Based on a questionnaire with open and closed questions, the study sought to characterize the students, identify knowledge and attitudes regarding the Rational Use of Medications while addressing the limits and possibilities of professional and ethical dispensing in practice. In addition, a group dynamics session - focus group - was held as a forum for debate on responsible dispensing. The results showed that students tended to be mature, currently employed and were predominately women. Displaying adequate knowledge on Rational Use of Medications and of the corresponding legislation, the students reported difficulties exercising compatible practice. While the diagnosis pointed to the need for student preparation to enable ethical dispensing, the Focus Group highlighted the possibility for inclusion of a forum for reflection and debate on the ethics of dispensing as part of the Pharmaceutical Technician training.O presente trabalho tem como proposta avaliar a formação do Técnico em Farmácia para o exercício da dispensação responsável. A partir de um questionário com perguntas fechadas e abertas, o estudo envolveu a caracterização dos alunos, a identificação de conhecimentos e atitudes em relação ao Uso Racional dos Medicamentos com vistas ao delineamento dos limites e possibilidades do exercício profissional ético na dispensação. Além disso, foi realizada uma dinâmica grupal - grupo focal - com o objetivo de apreciar a constituição de um espaço de reflexão sobre a dispensação responsável. Os resultados evidenciaram um alunato de maior idade, inserido no mercado de trabalho e predominância de mulheres. Dispondo de conhecimento adequado sobre o Uso Racional dos Medicamentos e da legislação correspondente os alunos fazem referência às dificuldades no exercício de uma pr

  11. Fundamental aspects of cathodic sputtering

    International Nuclear Information System (INIS)

    Harman, R.

    1979-01-01

    The main fundamental aspects and problems of cathodic sputtering used mainly for thin film deposition and sputter etching are discussed. Among many types of known sputtering techniques the radiofrequency /RF/ diode sputtering is the most universal one and is used for deposition of metals, alloys, metallic compounds, semiconductors and insulators. It seems that nowadays the largest number of working sputtering systems is of diode type. Sometimes also the dc or rf triode sputtering systems are used. The problems in these processes are practically equivalent and comparable with the problems in the diode method and therefore our discussion will be, in most cases applicable for both, the diode and triode methods

  12. Cathode-follower power amplifier

    International Nuclear Information System (INIS)

    Giordano, S.; Puglisi, M.

    1983-01-01

    In circular accelerators and particularly in storage rings it is essential that the total impedance, as seen by the beam, be kept below some critical value. A model of the accelerating system was built using a single-ended cathode-follower amplifier driving a ferrite-loaded cavity. The system operated at 234.5 kHz with a peak output voltage of +-10 kV on the gap. The dynamic output impedance, as measured on the gap, was < 15 ohms

  13. Pharmacists' role in opioid overdose: Kentucky pharmacists' willingness to participate in naloxone dispensing.

    Science.gov (United States)

    Freeman, Patricia R; Goodin, Amie; Troske, SuZanne; Strahl, Audra; Fallin, Amanda; Green, Traci C

    To assess pharmacists' willingness to initiate the dispensing of naloxone. As of 2015, Kentucky law permits certified pharmacists to dispense naloxone under a physician-approved protocol. Electronic survey (e-mail) gauging perception of pharmacists' role in opioid overdose and attitudes toward, and barriers to, naloxone dispensing. All Kentucky pharmacists with active licenses in 2015. Ordinal logistic regression was used to estimate the impact of pharmacist characteristics and attitudes on willingness to initiate naloxone dispensing, where the dependent variable was operationalized as a Likert-type question on a scale of 1 (not at all willing) to 6 (very willing). Of 4699 practicing Kentucky pharmacists, 1282 responded, of which 834 were community practitioners (response rate 27.3%). Pharmacists reported varying willingness to initiate naloxone dispensing, with 37.3% very willing (score 5 or 6) and 27.9% not willing (score 1 or 2). However, a majority of pharmacists reported willingness to dispense naloxone with a valid prescription (54.0%, score 5 or 6). Women pharmacists were 1.3 times more likely than men to be willing to initiate naloxone dispensing (95% confidence interval [CI] 1.0-1.6). Those who reported confidence in identifying individuals at risk for overdose were 1.2 times more likely to initiate dispensing, and those who reported confidence in ability to educate patients about overdose were 1.6 times more likely to express willingness to initiate naloxone dispensing (95% CIs, respectively, 1.0-1.3 and 1.4-1.8). Community pharmacists reported barriers to naloxone access at higher rates than pharmacists from other practice settings. Kentucky pharmacists are divided in their willingness to initiate naloxone dispensing; however, those who are confident in their ability to identify overdose risks are more willing. Increasing pharmacist confidence through appropriately designed education programs could facilitate pharmacist participation in naloxone

  14. Cathodic hydrogen charging of zinc

    International Nuclear Information System (INIS)

    Panagopoulos, C.N.; Georgiou, E.P.; Chaliampalias, D.

    2014-01-01

    Highlights: •Incorporation of hydrogen into zinc and formation of zinc hydrides. •Investigation of surface residual stresses due to hydrogen diffusion. •Effect of hydrogen diffusion and hydride formation on mechanical properties of Zn. •Hydrogen embrittlement phenomena in zinc. -- Abstract: The effect of cathodic hydrogen charging on the structural and mechanical characteristics of zinc was investigated. Hardening of the surface layers of zinc, due to hydrogen incorporation and possible formation of ZnH 2 , was observed. In addition, the residual stresses brought about by the incorporation of hydrogen atoms into the metallic matrix, were calculated by analyzing the obtained X-ray diffraction patterns. Tensile testing of the as-received and hydrogen charged specimens revealed that the ductility of zinc decreased significantly with increasing hydrogen charging time, for a constant value of charging current density, and with increasing charging current density, for a constant value of charging time. However, the ultimate tensile strength of this material was slightly affected by the hydrogen charging procedure. The cathodically charged zinc exhibited brittle transgranular fracture at the surface layers and ductile intergranular fracture at the deeper layers of the material

  15. Ion source with plasma cathode

    International Nuclear Information System (INIS)

    Yabe, E.

    1987-01-01

    A long lifetime ion source with plasma cathode has been developed for use in ion implantation. In this ion source, a plasma of a nonreactive working gas serves as a cathode in place of a thermionic tungsten filament used in the Freeman ion source. In an applied magnetic field, the plasma is convergent, i.e., filamentlike; in zero magnetic field, it turns divergent and spraylike. In the latter case, the plasma exhibits a remarkable ability when the working gas has an ionization potential larger than the feed gas. By any combination of a working gas of either argon or neon and a feed gas of AsF 5 or PF 5 , the lifetime of this ion source was found to be more than 90 h with an extraction voltage of 40 kV and the corresponding ion current density 20 mA/cm 2 . Mass spectrometry results show that this ion source has an ability of generating a considerable amount of As + and P + ions from AsF 5 and PF 5 , and hence will be useful for realizing a fully cryopumped ion implanter system. This ion source is also eminently suitable for use in oxygen ion production

  16. Pipelines cathodic protection design methodologies for impressed ...

    African Journals Online (AJOL)

    Several inadequate designs of cathodically polarized offshore and onshore pipelines have been reported in Nigeria owing to design complexity and application of the cathodic protection system. The present study focused on critical and detailed approach in impressed current and sacrificial anode design calculation ...

  17. MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT. NATIONAL SANITATION FOUNDATION STANDARD NO. 18.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI.

    THIS STANDARD COVERS THE SANITATION REQUIREMENTS FOR EQUIPMENT AND DEVICES WHICH DISPENSE FOOD OR BEVERAGE EITHER IN BULK OR PORTIONS. VENDING MACHINES OR BULK MILK DISPENSING EQUIPMENT ARE NOT COVERED IN THIS STANDARD. ITEMS COVERED INCLUDE THE BASIC PRINCIPLES OF DESIGN AND CONSTRUCTION, FOOD PROTECTION AND FREEDOM FROM HARBORAGES. MINIMUM…

  18. Poorly processed reusable surface disinfection tissue dispensers may be a source of infection.

    Science.gov (United States)

    Kampf, Günter; Degenhardt, Stina; Lackner, Sibylle; Jesse, Katrin; von Baum, Heike; Ostermeyer, Christiane

    2014-01-21

    Reusable surface disinfectant tissue dispensers are used in hospitals in many countries because they allow immediate access to pre-soaked tissues for targeted surface decontamination. On the other hand disinfectant solutions with some active ingredients may get contaminated and cause outbreaks. We determined the frequency of contaminated surface disinfectant solutions in reusable dispensers and the ability of isolates to multiply in different formulations. Reusable tissue dispensers with different surface disinfectants were randomly collected from healthcare facilities. Solutions were investigated for bacterial contamination. The efficacy of two surface disinfectants was determined in suspension tests against two isolated species directly from a contaminated solution or after 5 passages without selection pressure in triplicate. Freshly prepared use solutions were contaminated to determine survival of isolates. 66 dispensers containing disinfectant solutions with surface-active ingredients were collected in 15 healthcare facilities. 28 dispensers from nine healthcare facilities were contaminated with approximately 107 cells per mL of Achromobacter species 3 (9 hospitals), Achromobacter xylosoxidans or Serratia marcescens (1 hospital each). In none of the hospitals dispenser processing had been adequately performed. Isolates regained susceptibility to the disinfectants after five passages without selection pressure but were still able to multiply in different formulations from different manufacturers at room temperature within 7 days. Neglecting adequate processing of surface disinfectant dispensers has contributed to frequent and heavy contamination of use-solutions based on surface active ingredients. Tissue dispenser processing should be taken seriously in clinical practice.

  19. The fabrication of front electrodes of Si solar cell by dispensing printing

    International Nuclear Information System (INIS)

    Kim, Do-Hyung; Ryu, Sung-Soo; Shin, Dongwook; Shin, Jung-Han; Jeong, Jwa-Jin; Kim, Hyeong-Jun; Chang, Hyo Sik

    2012-01-01

    Highlights: ► We propose the process for the front silver electrode by employing dispensing method. ► The dispensing method is a non-contact printing process. ► The electrode by dispensing method has more uniform and narrower shape. ► The dispensing method helped to enhance the efficiency of solar cell by 0.8% absolute. - Abstract: The dispensing printing was applied to fabricate the front electrodes of silicon solar cell. In this method, a micro channel nozzle and normal Ag paste were employed. The aspect ratio and line width of electrodes could be controlled by the process variables such as the inner diameter of nozzle, dispensing speed, discharge pressure, and the gap between wafer and nozzle. For the nozzle with the inner diameter of 50 μm, the line width and aspect ratio of electrode were under 90 μm and more than ∼0.2, respectively. When comparing the efficiency of solar cell prepared by conventional screen printing and the dispensing printing, the latter exhibited 19.1%, which is 0.8% absolute higher than the former even with the same Ag paste. This is because the electrode by dispensing printing has uniform aspect ratio and narrow line width over the length of electrode.

  20. Model of dopant action in oxide cathodes

    International Nuclear Information System (INIS)

    Engelsen, Daniel den; Gaertner, Georg

    2005-01-01

    The paper describes an electrochemical model, which largely explains the formation of Ba in the oxide cathode at activation and normal operation. In a non-doped oxide cathode electrolysis of BaO is, besides the exchange reaction from the activators in the cathode nickel, an important source of Ba. By doping with rare earth oxides the conductivity of the oxide layer increases, which implies that the potential difference during current drawing over the oxide layer becomes lower and electrolysis of BaO is suppressed. This implies that the part of the electronic conductivity of the (Ba,Sr)O layer induced by the dopants also controls the sensitivity for poisoning: the higher the dopant level, the larger the sensitivity for poisoning. Furthermore, the suppression of electrolysis during normal operation largely explains why doped oxide cathodes have a better life performance than non-doped cathodes. Finally a hypothesis on the enhancement of sintering upon doping is presented

  1. Cathode Effects in Cylindrical Hall Thrusters

    Energy Technology Data Exchange (ETDEWEB)

    Granstedt, E.M.; Raitses, Y.; Fisch, N. J.

    2008-09-12

    Stable operation of a cylindrical Hall thruster (CHT) has been achieved using a hot wire cathode, which functions as a controllable electron emission source. It is shown that as the electron emission from the cathode increases with wire heating, the discharge current increases, the plasma plume angle reduces, and the ion energy distribution function shifts toward higher energies. The observed effect of cathode electron emission on thruster parameters extends and clarifies performance improvements previously obtained for the overrun discharge current regime of the same type of thruster, but using a hollow cathode-neutralizer. Once thruster discharge current saturates with wire heating, further filament heating does not affect other discharge parameters. The saturated values of thruster discharge parameters can be further enhanced by optimal placement of the cathode wire with respect to the magnetic field.

  2. Reliability Engineering

    CERN Document Server

    Lazzaroni, Massimo

    2012-01-01

    This book gives a practical guide for designers and users in Information and Communication Technology context. In particular, in the first Section, the definition of the fundamental terms according to the international standards are given. Then, some theoretical concepts and reliability models are presented in Chapters 2 and 3: the aim is to evaluate performance for components and systems and reliability growth. Chapter 4, by introducing the laboratory tests, puts in evidence the reliability concept from the experimental point of view. In ICT context, the failure rate for a given system can be

  3. Reliability training

    Science.gov (United States)

    Lalli, Vincent R. (Editor); Malec, Henry A. (Editor); Dillard, Richard B.; Wong, Kam L.; Barber, Frank J.; Barina, Frank J.

    1992-01-01

    Discussed here is failure physics, the study of how products, hardware, software, and systems fail and what can be done about it. The intent is to impart useful information, to extend the limits of production capability, and to assist in achieving low cost reliable products. A review of reliability for the years 1940 to 2000 is given. Next, a review of mathematics is given as well as a description of what elements contribute to product failures. Basic reliability theory and the disciplines that allow us to control and eliminate failures are elucidated.

  4. Real-time thermal imaging of solid oxide fuel cell cathode activity in working condition

    DEFF Research Database (Denmark)

    Montanini, Roberto; Quattrocchi, Antonino; Piccolo, Sebastiano

    2016-01-01

    Electrochemical methods such as voltammetry and electrochemical impedance spectroscopy are effective for quantifying solid oxide fuel cell (SOFC) operational performance, but not for identifying and monitoring the chemical processes that occur on the electrodes’ surface, which are thought...... to be strictly related to the SOFCs’ efficiency. Because of their high operating temperature, mechanical failure or cathode delamination is a common shortcoming of SOFCs that severely affects their reliability. Infrared thermography may provide a powerful tool for probing in situ SOFC electrode processes...... in detecting the onset of cell failure during normal operation and in monitoring cathode activity when the cell is fed with different types of fuels....

  5. Study of the three-step photoionization of uranium using a hollow cathode discharge tube

    International Nuclear Information System (INIS)

    Hu, Q.; Yin, L.; Zhang, Y.; Jin, C.; Cui, J.; Su, H.; Lin, F.

    1986-01-01

    The hollow cathode discharge (HCD) tube as a spectral light source has been developed. Because any element including refractory metals can be atomized by the cathode sputtering effect in HCD, a simple and reliable atomic vapor source produced by HCD has been widely used in laser spectroscopy. To the authors' knowledge, there is no previous work on the photoionization processes of metal atoms using an HCD tube. Here the authors report their study of the resonant three-step ionization of U in a homemade HCD tube

  6. Energy-efficiency potential of water dispensers; Energieeffizienzpotenzial bei Wasser-Dispensern

    Energy Technology Data Exchange (ETDEWEB)

    Grieder, T.

    2003-07-01

    This final report for the Swiss Federal Office of Energy presents the results of study carried out to assess the energy-savings potential available in the operation of water dispensers often found in banks, stores and offices. The energy consumption of three types of dispenser is examined and compared with American 'EnergyStar'-guidelines. The results of measurements made for day and night-time operation are presented and the energy-savings potentials offered by more appropriate operating scenarios are discussed. Recommendations are made to all parties involved, from the dispenser's manufacturer, water-supplier and service organisation through to the end user. For each category, a catalogue of measures that can be taken is presented, including modifications to the dispensers themselves and the installation of timers. Also, the energy consumption of dispensers is compared with that of using traditional mineral water bottles and a small conventional refrigerator.

  7. Influence of container structures and content solutions on dispensing time of ophthalmic solutions

    Directory of Open Access Journals (Sweden)

    Keiji Yoshikawa

    2010-05-01

    Full Text Available Keiji Yoshikawa1, Hiroshi Yamada21Yoshikawa Eye Clinic, Tokyo, Japan; 2Santen Pharmaceutical Co., Ltd., Osaka, JapanPurpose: To investigate the influence of container structures and content solutions on the time of dispensing from eye dropper bottles.Methods: Eye dropper bottle models, solution models (filtrate water/surfactant solution and a dispensing time measuring apparatus were prepared to measure the dispensing time.Results: With filtrate water and pressure thrust load of 0.3 MPa, the dispensing time significantly increased from 1.1 ± 0.5 seconds to 4.6 ± 1.1 seconds depending on the decrease of inner aperture diameters from 0.4 mm to 0.2 mm (P < 0.0001. When using the bottle models with inner aperture diameters of 0.4 mm or larger, the dispensing time became constant. The dispensing time using surfactant solution showed the same tendency as above. When pressure thrust load was large (0.07 MPa, the solution flew out continuously with inner aperture diameters of 0.4 mm or larger and the dispensing time could not be measured. The inner aperture diameter most strongly explained the variation of the dispensing time in both the content solutions in the multiple linear regression analysis (filtrate water: 46%, R2 = 0.462, surfactant solution: 56%, R2 = 0.563.Conclusions: Among content solutions and container structures, the dispensing time was mostly influenced by the diameter of the inner aperture of bottles.Keywords: dispensing time, model eye dropper bottle, model ophthalmic solution, nozzle internal space volume, nozzle inner aperture diameter

  8. Dispensing error rate after implementation of an automated pharmacy carousel system.

    Science.gov (United States)

    Oswald, Scott; Caldwell, Richard

    2007-07-01

    A study was conducted to determine filling and dispensing error rates before and after the implementation of an automated pharmacy carousel system (APCS). The study was conducted in a 613-bed acute and tertiary care university hospital. Before the implementation of the APCS, filling and dispensing rates were recorded during October through November 2004 and January 2005. Postimplementation data were collected during May through June 2006. Errors were recorded in three areas of pharmacy operations: first-dose or missing medication fill, automated dispensing cabinet fill, and interdepartmental request fill. A filling error was defined as an error caught by a pharmacist during the verification step. A dispensing error was defined as an error caught by a pharmacist observer after verification by the pharmacist. Before implementation of the APCS, 422 first-dose or missing medication orders were observed between October 2004 and January 2005. Independent data collected in December 2005, approximately six weeks after the introduction of the APCS, found that filling and error rates had increased. The filling rate for automated dispensing cabinets was associated with the largest decrease in errors. Filling and dispensing error rates had decreased by December 2005. In terms of interdepartmental request fill, no dispensing errors were noted in 123 clinic orders dispensed before the implementation of the APCS. One dispensing error out of 85 clinic orders was identified after implementation of the APCS. The implementation of an APCS at a university hospital decreased medication filling errors related to automated cabinets only and did not affect other filling and dispensing errors.

  9. Reliability calculations

    International Nuclear Information System (INIS)

    Petersen, K.E.

    1986-03-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very complex systems. In order to increase the applicability of the programs variance reduction techniques can be applied to speed up the calculation process. Variance reduction techniques have been studied and procedures for implementation of importance sampling are suggested. (author)

  10. Systems reliability/structural reliability

    International Nuclear Information System (INIS)

    Green, A.E.

    1980-01-01

    The question of reliability technology using quantified techniques is considered for systems and structures. Systems reliability analysis has progressed to a viable and proven methodology whereas this has yet to be fully achieved for large scale structures. Structural loading variants over the half-time of the plant are considered to be more difficult to analyse than for systems, even though a relatively crude model may be a necessary starting point. Various reliability characteristics and environmental conditions are considered which enter this problem. The rare event situation is briefly mentioned together with aspects of proof testing and normal and upset loading conditions. (orig.)

  11. Operating experience of an automated TLD dispensing system at CORAL facility

    International Nuclear Information System (INIS)

    Ajoy, K.C.; Dhanasekaran, A.; Arun, R.; Yuvaraj, N.; Karthikeyan, D.; Dheeraj, R.; Akila, R.; Santhanam, R.; Rajagopal, V.; Kumar, Amudhu Ramesh

    2016-01-01

    Monitoring of exposures to occupational workers on individual basis is a regulatory requirement to demonstrate compliance that the dose to the workers is well within the dose limit. Over three decades for monitoring of external exposures, CaSO 4 based Thermo luminescence dosimeters (TLDs), which exhibit the required accuracy, reliability and ruggedness have been employed. TLD cards with unique identification number are loaded in plastic cassettes along with photographs are placed in wooden racks at the entry of the controlled area of the plant. However, there is always a chance that a TLD may be misplaced, used by others or there could be a deliberate act of misuse or abuse. To circumvent this it was decided to install an automated TLD dispensing system with individual TLD tracking as well as locking arrangement. CORAL reprocessing facility at IGCAR was the first to install one such system at Kalpakkam and the operating experience of the system for the last two years is brought out in this paper

  12. Analysis of cathode geometry to minimize cathode erosion in direct current microplasma jet

    Energy Technology Data Exchange (ETDEWEB)

    Causa, Federica [Dipartimento di Scienze dell' Ambiente, della Sicurezza, del Territorio, degli Alimenti e della Salute, Universita degli studi di Messina, 98122 Messina (Italy); Ghezzi, Francesco; Caniello, Roberto; Grosso, Giovanni [Istituto di Fisica del Plasma, Consiglio Nazionale delle Ricerche, EURATOM-ENEA-CNR Association, Via R. Cozzi 53, 20125 Milano (Italy); Dellasega, David [Istituto di Fisica del Plasma, Consiglio Nazionale delle Ricerche, EURATOM-ENEA-CNR Association, Via R. Cozzi 53, 20125 Milano (Italy); Dipartimento di Energia, Politecnico di Milano, Via Ponzio 34/3, 20133 Milano (Italy)

    2012-12-15

    Microplasma jets are now widely used for deposition, etching, and materials processing. The present study focuses on the investigation of the influence of cathode geometry on deposition quality, for microplasma jet deposition systems in low vacuum. The interest here is understanding the influence of hydrogen on sputtering and/or evaporation of the electrodes. Samples obtained with two cathode geometries with tapered and rectangular cross-sections have been investigated experimentally by scanning electron microscopy and energy dispersion X-ray spectroscopy. Samples obtained with a tapered-geometry cathode present heavy contamination, demonstrating cathode erosion, while samples obtained with a rectangular-cross-section cathode are free from contamination. These experimental characteristics were explained by modelling results showing a larger radial component of the electric field at the cathode inner wall of the tapered cathode. As a result, ion acceleration is larger, explaining the observed cathode erosion in this case. Results from the present investigation also show that the ratio of radial to axial field components is larger for the rectangular geometry case, thus, qualitatively explaining the presence of micro-hollow cathode discharge over a wide range of currents observed in this case. In the light of the above findings, the rectangular cathode geometry is considered to be more effective to achieve cleaner deposition.

  13. Batteries: Overview of Battery Cathodes

    Energy Technology Data Exchange (ETDEWEB)

    Doeff, Marca M

    2010-07-12

    The very high theoretical capacity of lithium (3829 mAh/g) provided a compelling rationale from the 1970's onward for development of rechargeable batteries employing the elemental metal as an anode. The realization that some transition metal compounds undergo reductive lithium intercalation reactions reversibly allowed use of these materials as cathodes in these devices, most notably, TiS{sub 2}. Another intercalation compound, LiCoO{sub 2}, was described shortly thereafter but, because it was produced in the discharged state, was not considered to be of interest by battery companies at the time. Due to difficulties with the rechargeability of lithium and related safety concerns, however, alternative anodes were sought. The graphite intercalation compound (GIC) LiC{sub 6} was considered an attractive candidate but the high reactivity with commonly used electrolytic solutions containing organic solvents was recognized as a significant impediment to its use. The development of electrolytes that allowed the formation of a solid electrolyte interface (SEI) on surfaces of the carbon particles was a breakthrough that enabled commercialization of Li-ion batteries. In 1990, Sony announced the first commercial batteries based on a dual Li ion intercalation system. These devices are assembled in the discharged state, so that it is convenient to employ a prelithiated cathode such as LiCoO{sub 2} with the commonly used graphite anode. After charging, the batteries are ready to power devices. The practical realization of high energy density Li-ion batteries revolutionized the portable electronics industry, as evidenced by the widespread market penetration of mobile phones, laptop computers, digital music players, and other lightweight devices since the early 1990s. In 2009, worldwide sales of Li-ion batteries for these applications alone were US$ 7 billion. Furthermore, their performance characteristics (Figure 1) make them attractive for traction applications such as

  14. Design Of Photovoltaic Powered Cathodic Protection System

    Directory of Open Access Journals (Sweden)

    Golina Samir Adly

    2017-07-01

    Full Text Available The corrosion caused by chemical reaction between metallic structures and surrounding mediums such as soil or water .the CP cathodic protection system is used to protect metallic structure against corrosion. Cathodic protection CP used to minimize corrosion by utilizing an external source of electrical current which forces the entire structure to become a cathode. There are two Types of cathodic protection system Galvanic current Impressed current.the Galvanic current is called a sacrificial anode is connected to the protected structure cathode through a DC power supply. In Galvanic current system a current passes from the sacrificing anode to the protected structure .the sacrificial anode is corroded rather than causing the protected structure corrosion .protected structure requires a constant current to stop the corrosion which determined by area structure metal and the surrounding medium. The rains humidity are decrease soil resistivity and increase the DC current .The corrosion and over protection resulting from increase in the DC current is harmful for the metallic structure. This problem can be solved by conventional cathodic protection system by manual adjustment of DC voltage periodically to obtain a constant current .the manual adjustment of DC voltage depends on experience of the technician and using the accuracy of the measuring equipment. The errors of measuring current depend on error from the technician or error from the measuring equipment. the corrosion of structure may occur when the interval between two successive adjustment is long .An automatically regulated cathodic protection system is used to overcome problems from conventional cathodic protection system .the regulated cathodic protection system adjust the DC voltage of the system automatically when it senses the variations of surrounding medium resistivity so the DC current is constant at the required level.

  15. Cathodic behavior of zirconium in aqueous solutions

    International Nuclear Information System (INIS)

    Hine, F.; Yasuda, M.; Sato, H.

    1977-01-01

    The electrochemical behavior of Zr was studied by polarization measurements. The surface oxide and zirconium hydride formed by cathodic polarization of Zr have been examined by X-ray, SEM, and a hardness tester. Zirconium hydride would form on Zr cathode after the surface oxide is reduced at the potential, which is several hundred mV more noble than the predicted value shown by the Pourbaix diagram. The parameters for the hydrogen evolution reaction on the hydride formed Zr cathode differs from that on the oxide covered surface, which means that hydrogen evolution takes place on both surfaces under a different mechanism, while details are still veiled at present

  16. Rechargeable lithium/polymer cathode batteries

    Science.gov (United States)

    Osaka, Tetsuya; Nakajima, Toshiki; Shiota, Koh; Owens, Boone B.

    1989-06-01

    Polypyrrole (PPy) and polyaniline (PAn) were investigated for cathode materials of rechargeable lithium batteries. PPy films prepared with PF6(-) anion and/or platinum substrate precoated with nitrile butadiene rubber (NBR) were excellent cathode materials because of rough and/or highly oriented film structure. PAn films were successfully prepared from non-aqueous propylene carbonate solution containing aniline, CF3COOH and lithium perchlorate. Its acidity strongly affects the anion doping-undoping behavior. The PAn cathode prepared in high acidic solution (e.g., 4:1 ratio of acid:aniline) gives the excellent battery performance.

  17. Numerical study on rectangular microhollow cathode discharge

    International Nuclear Information System (INIS)

    He Shoujie; Ouyang Jiting; He Feng; Li Shang

    2011-01-01

    Rectangular microhollow cathode discharge in argon is investigated by using two-dimensional time-dependent self-consistent fluid model. The electric potential, electric field, particle density, and mean electron energy are calculated. The results show that hollow cathode effect can be onset in the present configuration, with strong electric field and high mean electron energy in the cathode fall while high density and quasineutral plasma in the negative glow. The potential well and electric filed reversal are formed in the negative glow region. It is suggested that the presence of large electron diffusion flux necessitates the field reversal and potential well.

  18. Cold cathode diode X-ray source

    International Nuclear Information System (INIS)

    Cooperstein, G.; Lanza, R.C.; Sohval, A.R.

    1983-01-01

    A cold cathode diode X-ray source for radiation imaging, especially computed tomography, comprises a rod-like anode and a generally cylindrical cathode, concentric with the anode. The spacing between anode and cathode is so chosen that the diode has an impedance in excess of 100 ohms. The anode may be of tungsten, or of carbon with a tungsten and carbon coating. An array of such diodes may be used with a closely packed array of detectors to produce images of rapidly moving body organs, such as the beating heart. (author)

  19. Plasma distribution of cathodic ARC deposition system

    International Nuclear Information System (INIS)

    Anders, S.; Raoux, S.; Krishnan, K.; MacGill, R.A.; Brown, I.G.

    1996-01-01

    The plasma distribution using a cathodic arc plasma source with and without magnetic macroparticle filter has been determined by depositing on a transparent plastic substrate and measuring the film absorption. It was found that the width of the distribution depends on the arc current, and it also depends on the cathode material which leads to a spatial separation of the elements when an alloy cathode is used. By applying a magnetic multicusp field near the exit of the magnetic filter, it was possible to modify the plasma distribution and obtain a flat plasma profile with a constant and homogeneous elemental distribution

  20. Cathode protection for underground steel tanks

    International Nuclear Information System (INIS)

    Angelovski, Zoran

    1998-01-01

    Cathodic protection of underground petroleum storage tanks and piping systems is acceptable for both economic and ecological reasons. With out the cathodic protection of underground steel reservoirs, short time after the exploitation, there was a bore as a result of underground corrosion. The bore causes ecological consequences and at the same time its repair needs big investments. Furthermore, there are great number of tanks placed near cities, so in the future this problem needs a special attention in order to preserve ecological surrounding. The topic of this paper is underground corrosion as well as cathodic protection of steel tanks for oil derivatives storage. (author)

  1. Cyclotron resonance in a cathode ray tube

    International Nuclear Information System (INIS)

    Gherbanovschi, N.; Tanasa, M.; Stoican, O.

    2002-01-01

    Absorption of the RF energy by the electron beam in a cathode ray tube due to the cyclotron resonance is described. The cathode ray tube is placed within a Helmholtz coils system supplied by a sawtooth current generator. In order to generate RF field and to detect RF absorption a gate dip-meter equipped with a FET transistor is used. The bias voltage variations of the FET transistors as a function of the magnetic field are recorded. The operating point of the cathode ray tube has been chosen so that the relaxation oscillations of the detection system can be observed. (authors)

  2. Human reliability

    International Nuclear Information System (INIS)

    Bubb, H.

    1992-01-01

    This book resulted from the activity of Task Force 4.2 - 'Human Reliability'. This group was established on February 27th, 1986, at the plenary meeting of the Technical Reliability Committee of VDI, within the framework of the joint committee of VDI on industrial systems technology - GIS. It is composed of representatives of industry, representatives of research institutes, of technical control boards and universities, whose job it is to study how man fits into the technical side of the world of work and to optimize this interaction. In a total of 17 sessions, information from the part of ergonomy dealing with human reliability in using technical systems at work was exchanged, and different methods for its evaluation were examined and analyzed. The outcome of this work was systematized and compiled in this book. (orig.) [de

  3. Microelectronics Reliability

    Science.gov (United States)

    2017-01-17

    inverters  connected in a chain. ................................................. 5  Figure 3  Typical graph showing frequency versus square root of...developing an experimental  reliability estimating methodology that could both illuminate the  lifetime  reliability of advanced devices,  circuits and...or  FIT of the device. In other words an accurate estimate of the device  lifetime  was found and thus the  reliability  that  can  be  conveniently

  4. Magnetron sputtered zinc oxide nanorods as thickness-insensitive cathode interlayer for perovskite planar-heterojunction solar cells.

    Science.gov (United States)

    Liang, Lusheng; Huang, Zhifeng; Cai, Longhua; Chen, Weizhong; Wang, Baozeng; Chen, Kaiwu; Bai, Hua; Tian, Qingyong; Fan, Bin

    2014-12-10

    Suitable electrode interfacial layers are essential to the high performance of perovskite planar heterojunction solar cells. In this letter, we report magnetron sputtered zinc oxide (ZnO) film as the cathode interlayer for methylammonium lead iodide (CH3NH3PbI3) perovskite solar cell. Scanning electron microscopy and X-ray diffraction analysis demonstrate that the sputtered ZnO films consist of c-axis aligned nanorods. The solar cells based on this ZnO cathode interlayer showed high short circuit current and power conversion efficiency. Besides, the performance of the device is insensitive to the thickness of ZnO cathode interlayer. Considering the high reliability and maturity of sputtering technique both in lab and industry, we believe that the sputtered ZnO films are promising cathode interlayers for perovskite solar cells, especially in large-scale production.

  5. Bacterial hand contamination and transfer after use of contaminated bulk-soap-refillable dispensers.

    Science.gov (United States)

    Zapka, Carrie A; Campbell, Esther J; Maxwell, Sheri L; Gerba, Charles P; Dolan, Michael J; Arbogast, James W; Macinga, David R

    2011-05-01

    Bulk-soap-refillable dispensers are prone to extrinsic bacterial contamination, and recent studies demonstrated that approximately one in four dispensers in public restrooms are contaminated. The purpose of this study was to quantify bacterial hand contamination and transfer after use of contaminated soap under controlled laboratory and in-use conditions in a community setting. Under laboratory conditions using liquid soap experimentally contaminated with 7.51 log(10) CFU/ml of Serratia marcescens, an average of 5.28 log(10) CFU remained on each hand after washing, and 2.23 log(10) CFU was transferred to an agar surface. In an elementary-school-based field study, Gram-negative bacteria on the hands of students and staff increased by 1.42 log(10) CFU per hand (26-fold) after washing with soap from contaminated bulk-soap-refillable dispensers. In contrast, washing with soap from dispensers with sealed refills significantly reduced bacteria on hands by 0.30 log(10) CFU per hand (2-fold). Additionally, the mean number of Gram-negative bacteria transferred to surfaces after washing with soap from dispensers with sealed-soap refills (0.06 log(10) CFU) was significantly lower than the mean number after washing with contaminated bulk-soap-refillable dispensers (0.74 log(10) CFU; P soap (P soap from bulk-soap-refillable dispensers can increase the number of opportunistic pathogens on the hands and may play a role in the transmission of bacteria in public settings.

  6. Dispensing processes impact apparent biological activity as determined by computational and statistical analyses.

    Directory of Open Access Journals (Sweden)

    Sean Ekins

    Full Text Available Dispensing and dilution processes may profoundly influence estimates of biological activity of compounds. Published data show Ephrin type-B receptor 4 IC50 values obtained via tip-based serial dilution and dispensing versus acoustic dispensing with direct dilution differ by orders of magnitude with no correlation or ranking of datasets. We generated computational 3D pharmacophores based on data derived by both acoustic and tip-based transfer. The computed pharmacophores differ significantly depending upon dispensing and dilution methods. The acoustic dispensing-derived pharmacophore correctly identified active compounds in a subsequent test set where the tip-based method failed. Data from acoustic dispensing generates a pharmacophore containing two hydrophobic features, one hydrogen bond donor and one hydrogen bond acceptor. This is consistent with X-ray crystallography studies of ligand-protein interactions and automatically generated pharmacophores derived from this structural data. In contrast, the tip-based data suggest a pharmacophore with two hydrogen bond acceptors, one hydrogen bond donor and no hydrophobic features. This pharmacophore is inconsistent with the X-ray crystallographic studies and automatically generated pharmacophores. In short, traditional dispensing processes are another important source of error in high-throughput screening that impacts computational and statistical analyses. These findings have far-reaching implications in biological research.

  7. Evaluation of community pharmacies regarding dispensing practices of antibiotics in two districts of central Nepal.

    Directory of Open Access Journals (Sweden)

    Mukhtar Ansari

    Full Text Available To evaluate the status of community pharmacies, their staff, and practices toward dispensing antibiotics.Cross-sectional, prospective.Community pharmacies in two districts of central Nepal, from March 2016 to May 2016.A systematic random sampling approach was adopted to sample 161 community pharmacies. Data on the registration status of pharmacies, qualification or training of dispensing staff, and the practice of dispensing antibiotics were collected using a pre-tested questionnaire. Face to face interviews were carried out by a previously trained interviewer. Data were analyzed for descriptive and inferential statistics using IBM SPSS Statistics 21.Among 161 community pharmacies, 25% were not registered and most of them were located in rural areas. It was typical (66.5% to dispense antibiotics without prescription and most (91.4% of the staffs involved in dispensing were non-pharmacists. Furthermore, the study revealed common practices of replacing one brand of antibiotic with other brands (66%, dispensing incomplete courses of antibiotics (73%, and not giving any advice regarding antibiotic use (39% or completion of a full course of therapy (80%. There were significant (p < 0.001 relationships between the location of pharmacies (rural vs urban and the qualifications of the pharmacy staff.Dispensing antibiotics without prescription and by non-pharmacists are common in this region. The study also found several issues regarding the irrational use of antibiotics. Thus, there is an urgent need to address these issues and promote the informed use of antibiotics.

  8. Nano-scale investigations of electric-dipole-layer enhanced field and thermionic emission from high current density cathodes

    Science.gov (United States)

    Vlahos, Vasilios

    Cesium iodide coated graphitic fibers and scandate cathodes are two important electron emission technologies. The coated fibers are utilized as field emitters for high power microwave sources. The scandate cathodes are promising thermionic cathode materials for pulsed power vacuum electron devices. This work attempts to understand the fundamental physical and chemical relationships between the atomic structure of the emitting cathode surfaces and the superior emission characteristics of these cathodes. Ab initio computational modeling in conjunction with experimental investigations was performed on coated fiber cathodes to understand the origin of their very low turn on electric field, which can be reduced by as much as ten-fold compared to uncoated fibers. Copious amounts of cesium and oxygen were found co-localized on the fiber, but no iodine was detected on the surface. Additional ab initio studies confirmed that cesium oxide dimers could lower the work function significantly. Surface cesium oxide dipoles are therefore proposed as the source of the observed reduction in the turn on electric field. It is also proposed that emission may be further enhanced by secondary electrons from cesium oxide during operation. Thermal conditioning of the coated cathode may be a mechanism by which surface cesium iodide is converted into cesium oxide, promoting the depletion of iodine by formation of volatile gas. Ab initio modeling was also utilized to investigate the stability and work functions of scandate structures. The work demonstrated that monolayer barium-scandium-oxygen surface structures on tungsten can dramatically lower the work function of the underlying tungsten substrate from 4.6 eV down to 1.16 eV, by the formation of multiple surface dipoles. On the basis of this work, we conclude that high temperature kinetics force conventional dispenser cathodes (barium-oxygen monolayers on tungsten) to operate in a non-equilibrium compositional steady state with higher than

  9. High-Precision Dispensing of Nanoliter Biofluids on Glass Pedestal Arrays for Ultrasensitive Biomolecule Detection.

    Science.gov (United States)

    Chen, Xiaoxiao; Liu, Yang; Xu, QianFeng; Zhu, Jing; Poget, Sébastien F; Lyons, Alan M

    2016-05-04

    Precise dispensing of nanoliter droplets is necessary for the development of sensitive and accurate assays, especially when the availability of the source solution is limited. Conventional approaches are limited by imprecise positioning, large shear forces, surface tension effects, and high costs. To address the need for precise and economical dispensing of nanoliter volumes, we developed a new approach where the dispensed volume is dependent on the size and shape of defined surface features, thus freeing the dispensing process from pumps and fine-gauge needles requiring accurate positioning. The surface we fabricated, called a nanoliter droplet virtual well microplate (nVWP), achieves high-precision dispensing (better than ±0.5 nL or ±1.6% at 32 nL) of 20-40 nL droplets using a small source drop (3-10 μL) on isolated hydrophilic glass pedestals (500 μm on a side) bonded to arrays of polydimethylsiloxane conical posts. The sharp 90° edge of the glass pedestal pins the solid-liquid-vapor triple contact line (TCL), averting the wetting of the glass sidewalls while the fluid is prevented from receding from the edge. This edge creates a sufficiently large energy barrier such that microliter water droplets can be poised on the glass pedestals, exhibiting contact angles greater >150°. This approach relieves the stringent mechanical alignment tolerances required for conventional dispensing techniques, shifting the control of dispensed volume to the area circumscribed by the glass edge. The effects of glass surface chemistry and dispense velocity on droplet volume were studied using optical microscopy and high-speed video. Functionalization of the glass pedestal surface enabled the selective adsorption of specific peptides and proteins from synthetic and natural biomolecule mixtures, such as venom. We further demonstrate how the nVWP dispensing platform can be used for a variety of assays, including sensitive detection of proteins and peptides by fluorescence

  10. Hand sanitizer-dispensing door handles increase hand hygiene compliance: a pilot study.

    Science.gov (United States)

    Babiarz, Lukasz S; Savoie, Brent; McGuire, Mark; McConnell, Lauren; Nagy, Paul

    2014-04-01

    Improving rates of hand hygiene compliance (HHC) has been shown to reduce nosocomial disease. We compared the HHC for a traditional wall-mounted unit and a novel sanitizer-dispensing door handle device in a hospital inpatient ultrasound area. HHC increased 24.5%-77.1% (P sanitizer-dispensing door handle, whereas it remained unchanged for the other rooms. Technical improvements like a sanitizer-dispensing door handle can improve hospital HHC. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  11. Modeling High Pressure Micro Hollow Cathode Discharges

    National Research Council Canada - National Science Library

    Boeuf, Jean-Pierre; Pitchford, Leanne

    2004-01-01

    This report results from a contract tasking CPAT as follows: The Grantee will perform theoretical modeling of point, surface, and volume high-pressure plasmas created using Micro Hollow Cathode Discharge sources...

  12. RF Electron Gun with Driven Plasma Cathode

    CERN Document Server

    Khodak, Igor

    2005-01-01

    It's known that RF guns with plasma cathodes based on solid-state dielectrics are able to generate an intense electron beam. In this paper we describe results of experimental investigation of the single cavity S-band RF gun with driven plasma cathode. The experimental sample of the cathode based on ferroelectric ceramics has been designed. Special design of the cathode permits to separate spatially processes of plasma development and electron acceleration. It has been obtained at RF gun output electron beam with particle energy ~500 keV, pulse current of 4 A and pulse duration of 80 ns. Results of experimental study of beam parameters are referred in. The gun is purposed to be applied as the intense electron beam source for electron linacs.

  13. Rare earth oxide doping in oxide cathodes

    International Nuclear Information System (INIS)

    Engelsen, Daniel den; Gaertner, Georg

    2006-01-01

    The effect on life performance and poisoning with O 2 by doping oxide cathodes with rare earth oxides and pseudo rare earth oxides, notably yttria, is qualitatively explained in terms of electrolysis of BaO during emission of electrons. Doped cathodes show less electrolysis and consume therefore less Ba during life: consequently, doped cathodes have a better life performance. However, the lower Ba-production makes doped cathodes more sensitive to oxygen poisoning. The experimentally found relation between conductivity and yttria concentration was the motive to propose a new model for the crystal imperfections in BaO. In this new imperfection model most Y 3+ -ions will combine with barium vacancies, therefore, the increase of the conductivity is modest and also the effect on the position of the Fermi level is modest. By assuming a combination of bulk and surface conductivity, the agreement between experiment and theory can be improved further

  14. Concentration changes due to cathodic protection

    NARCIS (Netherlands)

    Gellings, P.J.

    1978-01-01

    By solving the appropriate diffusion equations the concentration changes are calculated in the environment of underground structures protected cathodically. It is shown that these changes are negligible under all practical circumstances.

  15. Electrodeposition of uranium in stirred liquid cadmium cathode

    International Nuclear Information System (INIS)

    Koyama, T.; Tanaka, H.

    1997-01-01

    The electrodeposition of U in a liquid Cd cathode was known to be hampered by the formation of dendritic U on the Cd surface. Electrotransports of uranium to the stirred liquid Cd cathode were carried out at 773 K for different cathode current densities and different Reynolds number of stirring. The maximum amount of U taken in the liquid Cd cathode without forming dendrites was found to increase with an increasing Reynolds number of stirring and decrease with increasing cathode current density. (orig.)

  16. Plasma generation using the hollow cathod

    International Nuclear Information System (INIS)

    Moon, K.J.

    1983-01-01

    A hollow cathode of tungsten was adapted to an University of California, Berkely, LBL bucket ion source to investigate ion density fluctuations at the extractior grid. Fluctuations in plasma ion density are observed to range between 100kHz to 2 MHz. The observed fluctuation frequencies of plasma ion density are found to be inversely proportional to the square root of ion masses. It is guessed that the plasma fluctuation are also correlated with the hollow cathode length. (Author)

  17. Lyplal1 is dispensable for normal fat deposition in mice

    Directory of Open Access Journals (Sweden)

    Rachel A. Watson

    2017-12-01

    Full Text Available Genome-wide association studies (GWAS have detected association between variants in or near the Lysophospholipase-like 1 (LYPLAL1 locus and metabolic traits, including central obesity, fatty liver and waist-to-hip ratio. LYPLAL1 is also known to be upregulated in the adipose tissue of obese patients. However, the physiological role of LYPLAL1 is not understood. To investigate the function of Lyplal1 in vivo we investigated the phenotype of the Lyplal1tm1a(KOMPWtsi homozygous mouse. Body composition was unaltered in Lyplal1 knockout mice as assessed by dual-energy X-ray absorptiometry (DEXA scanning, both on normal chow and on a high-fat diet. Adipose tissue distribution between visceral and subcutaneous fat depots was unaltered, with no change in adipocyte cell size. The response to both insulin and glucose dosing was normal in Lyplal1tm1a(KOMPWtsi homozygous mice, with normal fasting blood glucose concentrations. RNAseq analysis of liver, muscle and adipose tissue confirmed that Lyplal1 expression was ablated with minimal additional changes in gene expression. These results suggest that Lyplal1 is dispensable for normal mouse metabolic physiology and that despite having been maintained through evolution Lyplal1 is not an essential gene, suggesting possible functional redundancy. Further studies will be required to clarify its physiological role.

  18. All-printed capacitors with continuous solution dispensing technology

    Science.gov (United States)

    Ge, Yang; Plötner, Matthias; Berndt, Andreas; Kumar, Amit; Voit, Brigitte; Pospiech, Doris; Fischer, Wolf-Joachim

    2017-09-01

    Printed electronics have been introduced into the commercial markets in recent years. Various printing technologies have emerged aiming to process printed electronic devices with low cost, environmental friendliness, and compatibility with large areas and flexible substrates. The aim of this study is to propose a continuous solution dispensing technology for processing all-printed thin-film capacitors on glass substrates using a leading-edge printing instrument. Among all printing technologies, this study provides concrete proof of the following outstanding advantages of this technology: high tolerance to inks, high throughput, low cost, and precise pattern transfers. Ag nanoparticle ink based on glycol ethers was used to print the electrodes. To obtain dielectric ink, a copolymer powder of poly(methyl methacrylate-co-benzoylphenyl methacrylate) containing crosslinkable side groups was dissolved in anisole. Various layouts were designed to support multiple electronic applications. Scanning electron microscopy and atomic force microscopy were used to investigate the all-printed capacitor layers formed using the proposed process. Additionally, the printed capacitors were electrically characterized under direct current and alternating current. The measured electrical properties of the printed capacitors were consistent with the theoretical results.

  19. Fascin 1 is dispensable for developmental and tumour angiogenesis

    Directory of Open Access Journals (Sweden)

    Yafeng Ma

    2013-09-01

    The actin bundling protein fascin 1 is not expressed in adult epithelial tissues, but during development it is transiently expressed in many different cell types, and later in adults it is expressed in a subset of immune cells, nervous tissues, endothelial cells, smooth muscle cells and pericytes. In contrast to the wealth of knowledge about the role of fascin 1 in cancer cell migration and invasion, little is known about the involvement of fascin 1 in angiogenesis. We speculated that as angiogenesis involves migration and invasion of tissues by endothelial cells, fascin 1 might have a role in both normal and tumour angiogenesis. Here, we provide evidence that loss of fascin 1 causes relatively minor reductions to angiogenesis during embryonic, postnatal and cancerous development by examining E12.5 hindbrains, postnatal retinas and B16F0 tumour cell allografts in fascin 1-null mice. We also find that in fascin 1 null tissues, endothelial cells display reduced filopodia formation during sprouting. We thus propose that fascin 1 expression promotes angiogenesis via filopodia formation, but is largely dispensable for both normal and tumour angiogenesis.

  20. A case of adverse drug reaction induced by dispensing error.

    Science.gov (United States)

    Gallelli, L; Staltari, O; Palleria, C; Di Mizio, G; De Sarro, G; Caroleo, B

    2012-11-01

    To report about a case of acute renal failure due to absence of communication between physician and patient. A 78 year old man with human immunodeficiency virus (HIV) accessed our hospital and was brought to our attention in August 2011 for severe renal failure. Clinical history revealed that he had been taking highly active antiretroviral therapy with lamivudine/abacavir and fosamprenavir since 2006. In April 2011 due to an augmentation in creatinine plasma levels, a reduction in lamivudine dosage to 100 mg/day and the prescription of abacavir 300 mg/day became necessary. Unfortunately, the patient took both lamivudine and abacavir therefore the association of the two medications (lamivudine/abacavir) lead to asthenia and acute renal failure within a few days. This case emphasizes the importance about how physicians must pay very careful attention during drug prescription, most particularly, as far as elderly patients are concerned. In fact, communication improvement between physicians and patients can prevent increase of adverse drug reactions related to drug dispensing, with consequential reduction of costs in the healthcare system. Copyright © 2012 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  1. Hydrothermal synthesis of cathode materials

    Science.gov (United States)

    Chen, Jiajun; Wang, Shijun; Whittingham, M. Stanley

    A number of cathodes are being considered for the next generation of lithium ion batteries to replace the expensive LiCoO 2 presently used. Besides the layered oxides, such as LiNi yMn yCo 1-2 yO 2, a leading candidate is lithium iron phosphate with the olivine structure. Although this material is inherently low cost, a manufacturing process that produces electrochemically active LiFePO 4 at a low cost is also required. Hydrothermal reactions are one such possibility. A number of pure phosphates have been prepared using this technique, including LiFePO 4, LiMnPO 4 and LiCoPO 4; this method has also successfully produced mixed metal phosphates, such as LiFe 0.33Mn 0.33Co 0.33PO 4. Ascorbic acid was found to be better than hydrazine or sugar at preventing the formation of ferric ions in aqueous media. When conductive carbons are added to the reaction medium excellent electrochemical behavior is observed.

  2. A simple low-cost of liquid I-131 dispenser for routine radiopharmaceutical dispensing at nuclear medicine department, Institut Kanser Negara

    Energy Technology Data Exchange (ETDEWEB)

    Said, M. A.; Suhaimi, N. E. F. [Fakulti Sains dan Teknologi, Universiti Kebangsaan Malaysia, 43600 UKM, Bangi Selangor (Malaysia); Ashhar, Z. N., E-mail: aminhpj@gmail.com [Institut Kanser Negara, No 4, Jalan P7, Presint 7, 62250 Putrajaya (Malaysia); Zainon, R. [Advanced Medical & Dental Institute, Universiti Sains Malaysia, Bertam, 13200, Kepala Batas, Pulau Pinang (Malaysia)

    2016-01-22

    In routine radiopharmaceutical Iodine-131 ({sup 131}I) dispensing, the amount of radiation dose received by the personnel depends on the distance between the personnel and the source, the time spent manipulating the source and the amount of shielding used to reduce the dose rate from the source. The novel iRAD-I131 dispenser using recycle {sup 131}I liquid lead pot will lead into low cost production, less maintenance and low dose received by the personnel that prepared the {sup 131}I. The new fabricated of low cost {sup 131}I dispenser was tested and the dose received by personnel were evaluated. The body of lead material is made from 2.5 cm lead shielded coated with epoxy paint to absorb the radiation dose up to 7.4 GBq of {sup 131} I. The lead pot was supported with two stainless steel rod. The Optically Stimulated Luminescence (OSL) nanodot was used in this study to measure the dose rate at both extremities for every personnel who prepared the {sup 131}I. Each OSL nanodot was attached at the fingertip. Three different personnel (experienced between one to ten years above in preparing the radiopharmaceuticals) were participated in this study. The average equivalent dose at right and left hand were 122.694 ± 121.637 µSv/GBq and 77.281 ± 62.146 µSv/GBq respectively. This study found that the dose exposure received using iRAD-I131 was less up to seven times compared to the conventional method. The comparison of experimental data using iRAD-I131 and established radiopharmaceutical dispenser was also discussed. The innovation of {sup 131}I dispenser is highly recommended in a small radiopharmaceutical facility with limited budget. The novel iRAD-I131 enables implementation of higher output liquid dispensing with low radiation dose to the personnel.

  3. Redefining reliability

    International Nuclear Information System (INIS)

    Paulson, S.L.

    1995-01-01

    Want to buy some reliability? The question would have been unthinkable in some markets served by the natural gas business even a few years ago, but in the new gas marketplace, industrial, commercial and even some residential customers have the opportunity to choose from among an array of options about the kind of natural gas service they need--and are willing to pay for. The complexities of this brave new world of restructuring and competition have sent the industry scrambling to find ways to educate and inform its customers about the increased responsibility they will have in determining the level of gas reliability they choose. This article discusses the new options and the new responsibilities of customers, the needed for continuous education, and MidAmerican Energy Company's experiment in direct marketing of natural gas

  4. Dispensing Equipment Testing with Mid-Level Ethanol/Gasoline Test Fluid: Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, K.; Chapin, J. T.

    2010-11-01

    The National Renewable Energy Laboratory's (NREL) Nonpetroleum-Based Fuel Task addresses the hurdles to commercialization of biomass-derived fuels and fuel blends. One such hurdle is the unknown compatibility of new fuels with current infrastructure, such as the equipment used at service stations to dispense fuel into automobiles. The U.S. Department of Energy's (DOE) Vehicle Technology Program and the Biomass Program have engaged in a joint project to evaluate the potential for blending ethanol into gasoline at levels higher than nominal 10 volume percent. This project was established to help DOE and NREL better understand any potentially adverse impacts caused by a lack of knowledge about the compatibility of the dispensing equipment with ethanol blends higher than what the equipment was designed to dispense. This report provides data about the impact of introducing a gasoline with a higher volumetric ethanol content into service station dispensing equipment from a safety and a performance perspective.

  5. 21 CFR 866.2440 - Automated medium dispensing and stacking device.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2440... stacking device is a device intended for medical purposes to dispense a microbiological culture medium into...

  6. Hand sanitizer dispensers and associated hospital-acquired infections: friend or fomite?

    Science.gov (United States)

    Eiref, Simon D; Leitman, I Michael; Riley, William

    2012-06-01

    Waterless alcohol-based hand sanitizers are an increasingly popular method of hand hygiene and help prevent hospital-acquired infection (HAI). Whether hand sanitizer dispensers (HSDs) may themselves harbor pathogens or act as fomites has not been reported. All HSDs in the surgical intensive care unit of an urban teaching hospital were cultured at three sites: The dispenser lever, the rear underside, and the area surrounding the dispensing nozzle. All HSDs yielded one or more bacterial species, including commensal skin flora and enteric gram-negative bacilli. Colonization was greatest on the lever, where there is direct hand contact. Hand sanitizer dispensers can become contaminated with pathogens that cause HAI and thus are potential fomites.

  7. The association between lifting an administrative restriction on antidepressant dispensing and treatment patterns in Iceland

    DEFF Research Database (Denmark)

    Thengilsdottir, G; Gardarsdottir, H; Almarsdóttir, Anna Birna

    2013-01-01

    On March 1st 2009, restrictions on the dispensing of selective serotonin reuptake inhibitors (SSRI) in Iceland were lifted. Incident rates and changes in early discontinuation and switching before and after the change were investigated.......On March 1st 2009, restrictions on the dispensing of selective serotonin reuptake inhibitors (SSRI) in Iceland were lifted. Incident rates and changes in early discontinuation and switching before and after the change were investigated....

  8. Multi-dose drug dispensing is a challenge across the primary-secondary care interface

    DEFF Research Database (Denmark)

    Reuther, Lene Orskov; Lysen, Charlotte; Faxholm, Mette

    2011-01-01

    Multi-dose drug dispensing (MDDD) signifies that the patient's medicine is packed in disposable bags corresponding to the dose that should be taken. The purpose of the present study was to investigate how a hospital MDDD instruction was followed.......Multi-dose drug dispensing (MDDD) signifies that the patient's medicine is packed in disposable bags corresponding to the dose that should be taken. The purpose of the present study was to investigate how a hospital MDDD instruction was followed....

  9. [Quality evaluation of rhubarb dispensing granules based on multi-component simultaneous quantitative analysis and bioassay].

    Science.gov (United States)

    Tan, Peng; Zhang, Hai-Zhu; Zhang, Ding-Kun; Wu, Shan-Na; Niu, Ming; Wang, Jia-Bo; Xiao, Xiao-He

    2017-07-01

    This study attempts to evaluate the quality of Chinese formula granules by combined use of multi-component simultaneous quantitative analysis and bioassay. The rhubarb dispensing granules were used as the model drug for demonstrative study. The ultra-high performance liquid chromatography (UPLC) method was adopted for simultaneously quantitative determination of the 10 anthraquinone derivatives (such as aloe emodin-8-O-β-D-glucoside) in rhubarb dispensing granules; purgative biopotency of different batches of rhubarb dispensing granules was determined based on compound diphenoxylate tablets-induced mouse constipation model; blood activating biopotency of different batches of rhubarb dispensing granules was determined based on in vitro rat antiplatelet aggregation model; SPSS 22.0 statistical software was used for correlation analysis between 10 anthraquinone derivatives and purgative biopotency, blood activating biopotency. The results of multi-components simultaneous quantitative analysisshowed that there was a great difference in chemical characterizationand certain differences inpurgative biopotency and blood activating biopotency among 10 batches of rhubarb dispensing granules. The correlation analysis showed that the intensity of purgative biopotency was significantly correlated with the content of conjugated anthraquinone glycosides (Panalysis and bioassay can achieve objective quantification and more comprehensive reflection on overall quality difference among different batches of rhubarb dispensing granules. Copyright© by the Chinese Pharmaceutical Association.

  10. Separation of prescribing and dispensing in Malaysia: the history and challenges.

    Science.gov (United States)

    Tiong, John Jeh Lung; Mai, Chun Wai; Gan, Pou Wee; Johnson, James; Mak, Vivienne Sook Li

    2016-08-01

    This article serves as an update to the work by Shafie et al. (2012) which previously reviewed the benefits of policies separating prescribing and dispensing in various countries to advocate its implementation in Malaysia. This article seeks to strengthen the argument by highlighting not only the weaknesses of the Malaysian health care system from the historical, professional and economic viewpoints but also the shortcomings of both medical and pharmacy professions in the absence of separation of dispensing. It also provides a detailed insight into the ongoing initiatives taken to consolidate the role of pharmacists in the health care system in the advent of separation of dispensing. Under the two tier system in Malaysia at present, the separation of prescribing and dispensing is implemented only in government hospitals. The absence of this separation in the private practices has led to possible profit-oriented medical and pharmacy practices which hinder safe and cost-effective delivery of health services. The call for separation of dispensing has gained traction over the years despite various hurdles ranging from the formidable resistance from the medical fraternity to the public's scepticism towards the new policy. With historical testament and present evidence pointing towards the merits of a system in which doctors prescribe and pharmacists dispense, the implementation of this health care model is justified. © 2016 The Authors. IJPP © 2016 Royal Pharmaceutical Society.

  11. Nanoliter Centrifugal Liquid Dispenser Coupled with Superhydrophobic Microwell Array Chips for High-Throughput Cell Assays

    Directory of Open Access Journals (Sweden)

    Yuyi Wang

    2018-06-01

    Full Text Available Microfluidic systems have been regarded as a potential platform for high-throughput screening technology in drug discovery due to their low sample consumption, high integration, and easy operation. The handling of small-volume liquid is an essential operation in microfluidic systems, especially in investigating large-scale combination conditions. Here, we develop a nanoliter centrifugal liquid dispenser (NanoCLD coupled with superhydrophobic microwell array chips for high-throughput cell-based assays in the nanoliter scale. The NanoCLD consists of a plastic stock block with an array of drilled through holes, a reagent microwell array chip (reagent chip, and an alignment bottom assembled together in a fixture. A simple centrifugation at 800 rpm can dispense ~160 nL reagents into microwells in 5 min. The dispensed reagents are then delivered to cells by sandwiching the reagent chip upside down with another microwell array chip (cell chip on which cells are cultured. A gradient of doxorubicin is then dispensed to the cell chip using the NanoCLD for validating the feasibility of performing drug tests on our microchip platform. This novel nanoliter-volume liquid dispensing method is simple, easy to operate, and especially suitable for repeatedly dispensing many different reagents simultaneously to microwells.

  12. 2013 Estorm - Invited Paper - Cathode Materials Review

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Claus [ORNL; Mohanty, Debasish [ORNL; Li, Jianlin [ORNL; Wood III, David L [ORNL

    2014-01-01

    The electrochemical potential of cathode materials defines the positive side of the terminal voltage of a battery. Traditionally, cathode materials are the energy-limiting or voltage-limiting electrode. One of the first electrochemical batteries, the voltaic pile invented by Alessandro Volta in 1800 (Phil. Trans. Roy. Soc. 90, 403 431) had a copper-zinc galvanic element with a terminal voltage of 0.76 V. Since then, the research community has increased capacity and voltage for primary (nonrechargeable) batteries and round-trip efficiency for secondary (rechargeable) batteries. Successful secondary batteries have been the lead acid with a lead oxide cathode and a terminal voltage of 2.1 V and later the NiCd with a nickel(III) oxide hydroxide cathode and a 1.2 V terminal voltage. The relatively low voltage of those aqueous systems and the low round-trip efficiency due to activation energies in the conversion reactions limited their use. In 1976, Wittingham (J. Electrochem. Soc., 123, 315) and Besenhard (J Power Sources 1(3), 267) finally enabled highly reversible redox reactions by intercalation of lithium ions instead of by chemical conversion. In 1980, Goodenough and Mizushima (Mater. Res. Bull. 15, 783 789) demonstrated a high-energy and high-power LiCoO2 cathode, allowing for an increase of terminal voltage far beyond 3 V. Over the past four decades, the international research community has further developed cathode materials of many varieties. Current state-of-the-art cathodes demonstrate voltages beyond any known electrolyte stability window, bringing electrolyte research once again to the forefront of battery research.

  13. Impact of alternative interventions on changes in generic dispensing rates.

    Science.gov (United States)

    O'Malley, A James; Frank, Richard G; Kaddis, Atheer; Rothenberg, Barbara M; McNeil, Barbara J

    2006-10-01

    To evaluate the effectiveness of four alternative interventions (member mailings, advertising campaigns, free generic drug samples to physicians, and physician financial incentives) used by a major health insurer to encourage its members to switch to generic drugs. Using claim-level data from Blue Cross Blue Shield of Michigan, we evaluated the success of four interventions implemented during 2000-2003 designed to increase the use of generic drugs among its members. Around 13 million claims involving seven important classes of drugs were used to assess the effectiveness of the interventions. For each intervention a control group was developed that most closely resembled the corresponding intervention group. Logistic regression models with interaction effects between the treatment group (intervention versus control) and the status of the intervention (active versus not active) were used to evaluate if the interventions had an effect on the generic dispensing rate (GDR). Because the mail order pharmacy was considered more aggressive at converting prescriptions to generics, separate generic purchasing models were fitted to retail and mail order claims. In secondary analyses separate models were also fitted to claims involving a new condition and claims refilled for preexisting conditions. The interventions did not appear to increase the market penetration of generic drugs for either retail or mail order claims, or for claims involving new or preexisting conditions. In addition, we found that the ratio of copayments for brand name to generic drugs had a large positive effect on the GDR. The interventions did not appear to directly influence the GDR. Financial incentives expressed to consumers through benefit designs have a large influence on their switching to generic drugs and on the less-costly mail-order mode of purchase.

  14. Justice Dispensation through the Alternative Dispute Resolution System in India

    Directory of Open Access Journals (Sweden)

    Krishna Agrawal

    2014-01-01

    Full Text Available The Law Commission of India in its 222nd report emphasized the need for Alternative Disputes Resolution (ADR for the dispensation of justice, because the courts are inaccessible owing to various factors, e.g., poverty, social and political backwardness, illiteracy, ignorance, procedural formalities and inordinate delay in judgments. During the ancient period the disputes were resolved in an informal manner by neutral third persons or people’s court in villages and it continued till the middle of the 20th century. Unfortunately, after the Independence of India in 1947, this system was dissuaded and the government permitted to continue the adversarial system of justice. In 1980, a committee was set up. It recommended Lok Adalats (People’s Courts. In 1987, the Legal Services Authorities Act was enacted. This Act obligates the states to provide free legal aid to poor persons. Besides this, the Act provides for the establishment of permanent Lok Adalats.This is one of the important modes of ADR. Lok Adalats have been established in all the districts of the country. They bring conciliatory settlement in complicated cases arising out of matrimonial, landlord-tenants, property, insurance and commercial disputes. There are four methods of ADR, viz., negotiation, mediation, conciliation and arbitration. Mediation and arbitration are widely preferred. They are alternatives to litigation. The Arbitration Act for the first time was enacted in 1889 and it was subsequently amended many times. On the objections raised by the Supreme Court of India and also on the adoption of UNCITRAL Model Law on International Commercial Arbitration, in 1996 Arbitration and Conciliation Act was enacted. This law is almost the same as is almost in all the countries.Further, the Government of India established International Centre for Alternative Disputes Resolution (CADR with the objectives of promotion, propagation, and popularizing the settlement of domestic and

  15. Impact of Pharmacists’ Religious and Personal Beliefs in Dispensing Contraceptives

    Directory of Open Access Journals (Sweden)

    Anna Krupa

    2016-10-01

    Full Text Available Background: Until recently, pharmacies were not permitted to dispense any emergency contraceptives to women to prevent pregnancy. No legal statutes existed under which pharmacists with religious, moral or ethical objections could refuse to fill a prescription for contraceptives, nor were there direct guidelines describing the pharmacist’s professional obligations. Objectives: The purpose of this study is to explore the frequency of cases in which pharmacists have refused, due to their personal beliefs, to provide counsel regarding contraceptives or have refused to refer to a patient to a different pharmacist or healthcare provider. This study will compare and contrast the differences between independent pharmacies and chain pharmacies (i.e. time spent, location, most common recommended contraception. Finally, this study will compare the results evident between male pharmacists and female pharmacists. Method: Quantitative method employed uses two interview questions directed to pharmacists: (1 “I am moving in with my fiancée/boyfriend next month and I have never used contraceptives. What are my options?” (2 “If I use a condom and it breaks, do I have any choices to prevent pregnancy after the fact?” The survey was conducted in two locations, the greater Philadelphia area and Hershey, PA. The survey was conducted through face-to-face interactions with pharmacists, either employed at independent pharmacy or at a chain pharmacy. Data collected from each pharmacist included number of approximate age/gender; minutes spent in each consultation with a patient; the kind of privacy provided during the consultation; and the referrals given, if any. Results: Fifty (50 pharmacists were interviewed. No pharmacist indicated that counseling would be denied, although one (1 pharmacist refused to counsel on Plan B and four (4 pharmacists referred the interviewer to a doctor immediately, indicating that all medications require a prescription. Two (2

  16. Prescribed 3-D Direct Writing of Suspended Micron/Sub-micron Scale Fiber Structures via a Robotic Dispensing System.

    Science.gov (United States)

    Yuan, Hanwen; Cambron, Scott D; Keynton, Robert S

    2015-06-12

    A 3-axis dispensing system is utilized to control the initiating and terminating fiber positions and trajectory via the dispensing software. The polymer fiber length and orientation is defined by the spatial positioning of the dispensing system 3-axis stages. The fiber diameter is defined by the prescribed dispense time of the dispensing system valve, the feed rate (the speed at which the stage traverses from an initiating to a terminating position), the gauge diameter of the dispensing tip, the viscosity and surface tension of the polymer solution, and the programmed drawing length. The stage feed rate affects the polymer solution's evaporation rate and capillary breakup of the filaments. The dispensing system consists of a pneumatic valve controller, a droplet-dispensing valve and a dispensing tip. Characterization of the direct write process to determine the optimum combination of factors leads to repeatedly acquiring the desired range of fiber diameters. The advantage of this robotic dispensing system is the ease of obtaining a precise range of micron/sub-micron fibers onto a desired, programmed location via automated process control. Here, the discussed self-assembled micron/sub-micron scale 3D structures have been employed to fabricate suspended structures to create micron/sub-micron fluidic devices and bioengineered scaffolds.

  17. Beryllium electrodeposition on aluminium cathode from chloride melts

    International Nuclear Information System (INIS)

    Nichkov, I.F.; Novikov, E.A.; Serebryakov, G.A.; Kanashin, Yu.P.; Sardyko, G.N.

    1980-01-01

    Cathodic processes during beryllium deposition on liquid and solid aluminium cathodes are investigated. Mixture of sodium, potassium and beryllium chloride melts served as an lectrolyte. Beryllium ion discharge at the expense of alloy formation takes place at more positive potentials than on an indifferent cathode at low current densities ( in the case of liquid aluminium cathode). Metallographic analysis and measurements of microhardness have shown, that the cathodic product includes two phases: beryllium solid solution in aluminium and metallic beryllium. It is concluded, that aluminium-beryllium alloys with high cathodic yield by current can be obtained by the electrolytic method

  18. Comparison of hollow cathode discharge plasma configurations

    International Nuclear Information System (INIS)

    Farnell, Casey C; Farnell, Cody C; Williams, John D

    2011-01-01

    Hollow cathodes used in plasma contactor and electric propulsion devices provide electrons for sustaining plasma discharges and enabling plasma bridge neutralization. Life tests show erosion on hollow cathodes exposed to the plasma environment produced in the region downstream of these devices. To explain the observed erosion, plasma flow field measurements are presented for hollow cathode generated plasmas using both directly immersed probes and remotely located plasma diagnostics. Measurements on two cathode discharge configurations are presented: (1) an open, no magnetic field configuration and (2) a setup simulating the discharge chamber environment of an ion thruster. In the open cathode configuration, large amplitude plasma potential oscillations, ranging from 20 to 85 V within a 34 V discharge, were observed using a fast response emissive probe. These oscillations were observed over a dc potential profile that included a well-defined potential hill structure. A remotely located electrostatic analyzer (ESA) was used to measure the energy of ions produced within the plasma, and energies were detected that met, and in some cases exceeded, the peak oscillatory plasma potentials detected by the emissive probe. In the ion thruster discharge chamber configuration, plasma potentials from the emissive probe again agreed with ion energies recorded by the remotely located ESA; however, much lower ion energies were detected compared with the open configuration. A simplified ion-transit model that uses temporal and spatial plasma property measurements is presented and used to predict far-field plasma streaming properties. Comparisons between the model and remote measurements are presented.

  19. Investigations Of A Pulsed Cathodic Vacuum Arc

    Science.gov (United States)

    Oates, T. W. H.; Pigott, J.; Denniss, P.; Mckenzie, D. R.; Bilek, M. M. M.

    2003-06-01

    Cathodic vacuum arcs are well established as a method for producing thin films for coatings and as a source of metal ions. Research into DC vacuum arcs has been going on for over ten years in the School of Physics at the University of Sydney. Recently a project was undertaken in the school to design and build a pulsed CVA for use in the investigation of plasma sheaths and plasma immersion ion implantation. Pulsed cathodic vacuum arcs generally have a higher current and plasma density and also provide a more stable and reproducible plasma density than their DC counterparts. Additionally it has been shown that if a high repetition frequency can be established the deposition rate of pulsed arcs is equal to or greater than that of DC arcs with a concomitant reduction in the rate of macro-particle formation. We present here results of our investigations into the building of a center-triggered pulsed cathodic vacuum arc. The design of the power supply and trigger mechanism and the geometry of the anode and cathode are examined. Observations of type I and II arc spots using a CCD camera, and cathode spot velocity dependence on arc current will be presented. The role of retrograde motion in a high current pulsed arc is discussed.

  20. Manganese Dioxide As Rechargeable Magnesium Battery Cathode

    International Nuclear Information System (INIS)

    Ling, Chen; Zhang, Ruigang

    2017-01-01

    Rechargeable magnesium battery (rMB) has received increased attention as a promising alternative to current Li-ion technology. However, the lack of appropriate cathode that provides high-energy density and good sustainability greatly hinders the development of practical rMBs. To date, the successful Mg 2+ -intercalation was only achieved in only a few cathode hosts, one of which is manganese dioxide. This review summarizes the research activity of studying MnO 2 in magnesium cells. In recent years, the cathodic performance of MnO 2 was impressively improved to the capacity of >150–200 mAh g −1 at voltage of 2.6–2.8 V with cyclability to hundreds or more cycles. In addition to reviewing electrochemical performance, we sketch a mechanistic picture to show how the fundamental understanding about MnO 2 cathode has been changed and how it paved the road to the improvement of cathode performance.

  1. Manganese Dioxide As Rechargeable Magnesium Battery Cathode

    Energy Technology Data Exchange (ETDEWEB)

    Ling, Chen, E-mail: chen.ling@toyota.com; Zhang, Ruigang [Toyota Research Institute of North America, Ann Arbor, MI (United States)

    2017-11-03

    Rechargeable magnesium battery (rMB) has received increased attention as a promising alternative to current Li-ion technology. However, the lack of appropriate cathode that provides high-energy density and good sustainability greatly hinders the development of practical rMBs. To date, the successful Mg{sup 2+}-intercalation was only achieved in only a few cathode hosts, one of which is manganese dioxide. This review summarizes the research activity of studying MnO{sub 2} in magnesium cells. In recent years, the cathodic performance of MnO{sub 2} was impressively improved to the capacity of >150–200 mAh g{sup −1} at voltage of 2.6–2.8 V with cyclability to hundreds or more cycles. In addition to reviewing electrochemical performance, we sketch a mechanistic picture to show how the fundamental understanding about MnO{sub 2} cathode has been changed and how it paved the road to the improvement of cathode performance.

  2. Investigations Of A Pulsed Cathodic Vacuum Arc

    International Nuclear Information System (INIS)

    Oates, T.W.H.; Pigott, J.; Denniss, P.; Mckenzie, D.R.; Bilek, M.M.M.

    2003-01-01

    Cathodic vacuum arcs are well established as a method for producing thin films for coatings and as a source of metal ions. Research into DC vacuum arcs has been going on for over ten years in the School of Physics at the University of Sydney. Recently a project was undertaken in the school to design and build a pulsed CVA for use in the investigation of plasma sheaths and plasma immersion ion implantation. Pulsed cathodic vacuum arcs generally have a higher current and plasma density and also provide a more stable and reproducible plasma density than their DC counterparts. Additionally it has been shown that if a high repetition frequency can be established the deposition rate of pulsed arcs is equal to or greater than that of DC arcs with a concomitant reduction in the rate of macro-particle formation. We present here results of our investigations into the building of a center-triggered pulsed cathodic vacuum arc. The design of the power supply and trigger mechanism and the geometry of the anode and cathode are examined. Observations of type I and II arc spots using a CCD camera, and cathode spot velocity dependence on arc current will be presented. The role of retrograde motion in a high current pulsed arc is discussed

  3. The influence of cathode excavation of cathodic arc evaporator on thickness uniformity and erosion products angle distribution

    Directory of Open Access Journals (Sweden)

    D. V. Duhopel'nikov

    2014-01-01

    Full Text Available Cathodic arc evaporators are used for coating with functional films. Prolonged or buttend evaporators may be used for this purposes. In butt-end evaporator the cathode spots move continuously on the cathode work surface and evaporate cathode material. High depth excavation profile forms on the cathode work surface while the thick coating precipitation (tens or hundreds of microns. The cathode excavation profile is shaped like a “cup” with high walls for electrostatic discharge stabilization systems with axial magnetic fields. Cathode spots move on the bottom of the “cup”. It is very likely that high “cup” walls are formed as a result of lasting work time influence on the uniformity of precipitated films.In the present work the influence of excavation profile walls height on the uniformity of precipitated coating was carried out. The high profile walls are formed due to lasting work of DC vacuum arc evaporator. The cathode material used for tests was 3003 aluminum alloy. The extended substrate was placed parallel to the cathode work surface. Thickness distribution along the substrate length with the new cathode was obtained after 6 hours and after 12 hours of continuous operation.The thickness distribution of precipitated coating showed that the cathode excavation has an influence on the angular distribution of the matter escaping the cathode. It can be clearly seen from the normalized dependence coating thickness vs the distance from the substrate center. Also the angular distribution of the matter flow from the cathode depending on the cathode working time was obtained. It was shown that matter flow from the cathode differs from the LambertKnudsen law. The more the cathode excavation the more this difference.So, cathode excavation profile has an influence on the uniformity of precipitated coating and it is necessary to take in account the cathode excavation profile while coating the thick films.

  4. Oxide cathodes produced by plasma deposition

    International Nuclear Information System (INIS)

    Scheitrum, G.; Caryotakis, G.; Pi, T.; Umstattd, R.; Brown, I.; Montiero, O.

    1997-01-01

    These are two distinct applications for high-current-density, long-life thermionic cathodes. The first application is as a substitute for explosive emission cathodes used in high-power microwave (HPM) devices being developed for Air Force programs. The second application is in SLAC's X-band klystrons for the Next Linear Collider (NLC). SLAC, UCD, and LBL are developing a plasma deposition process that eliminates the problems with binders, carbonate reduction, peeling, and porosity. The emission layer is deposited using plasma deposition of metallic barium in vacuum with an oxygen background gas. An applied bias voltage drives the oxide plasma into the nickel surface. Since the oxide is deposited directly, it does not have problems with poisoning from a hydrocarbon binder. The density of the oxide layer is increased from the 40--50% for standard oxide cathodes to nearly 100% for plasma deposition

  5. Automated drug dispensing system reduces medication errors in an intensive care setting.

    Science.gov (United States)

    Chapuis, Claire; Roustit, Matthieu; Bal, Gaëlle; Schwebel, Carole; Pansu, Pascal; David-Tchouda, Sandra; Foroni, Luc; Calop, Jean; Timsit, Jean-François; Allenet, Benoît; Bosson, Jean-Luc; Bedouch, Pierrick

    2010-12-01

    We aimed to assess the impact of an automated dispensing system on the incidence of medication errors related to picking, preparation, and administration of drugs in a medical intensive care unit. We also evaluated the clinical significance of such errors and user satisfaction. Preintervention and postintervention study involving a control and an intervention medical intensive care unit. Two medical intensive care units in the same department of a 2,000-bed university hospital. Adult medical intensive care patients. After a 2-month observation period, we implemented an automated dispensing system in one of the units (study unit) chosen randomly, with the other unit being the control. The overall error rate was expressed as a percentage of total opportunities for error. The severity of errors was classified according to National Coordinating Council for Medication Error Reporting and Prevention categories by an expert committee. User satisfaction was assessed through self-administered questionnaires completed by nurses. A total of 1,476 medications for 115 patients were observed. After automated dispensing system implementation, we observed a reduced percentage of total opportunities for error in the study compared to the control unit (13.5% and 18.6%, respectively; perror (20.4% and 13.5%; perror showed a significant impact of the automated dispensing system in reducing preparation errors (perrors caused no harm (National Coordinating Council for Medication Error Reporting and Prevention category C). The automated dispensing system did not reduce errors causing harm. Finally, the mean for working conditions improved from 1.0±0.8 to 2.5±0.8 on the four-point Likert scale. The implementation of an automated dispensing system reduced overall medication errors related to picking, preparation, and administration of drugs in the intensive care unit. Furthermore, most nurses favored the new drug dispensation organization.

  6. Synchrotron Investigations of SOFC Cathode Degradation

    Energy Technology Data Exchange (ETDEWEB)

    Idzerda, Yves

    2013-09-30

    The atomic variations occurring in cathode/electrolyte interface regions of La{sub 1-x}Sr{sub x}Co{sub y}Fe{sub 1-y}O{sub 3-δ} (LSCF) cathodes and other SOFC related materials have been investigated and characterized using soft X-ray Absorption Spectroscopy (XAS) and diffuse soft X-ray Resonant Scattering (XRS). X-ray Absorption Spectroscopy in the soft X-ray region (soft XAS) is shown to be a sensitive technique to quantify the disruption that occurs and can be used to suggest a concrete mechanism for the degradation. For LSC, LSF, and LSCF films, a significant degradation mechanism is shown to be Sr out-diffusion. By using the XAS spectra of hexavalent Cr in SrCrO4 and trivalent Cr in Cr2O3, the driving factor for Sr segregation was identified to be the oxygen vacancy concentration at the anode and cathode side of of symmetric LSCF/GDC/LSCF heterostructures. This is direct evidence of vacancy induced cation diffusion and is shown to be a significant indicator of cathode/electrolyte interfacial degradation. X-ray absorption spectroscopy is used to identify the occupation of the A-sites and B-sites for LSC, LSF, and LSCF cathodes doped with other transition metals, including doping induced migration of Sr to the anti-site for Sr, a significant cathode degradation indicator. By using spatially resolved valence mapping of Co, a complete picture of the surface electrochemistry can be determined. This is especially important in identifying degradation phenomena where the degradation is spatially localized to the extremities of the electrochemistry and not the average. For samples that have electrochemical parameters that are measured to be spatially uniform, the Co valence modifications were correlated to the effects of current density, overpotential, and humidity.

  7. Ferroelectric Cathodes in Transverse Magnetic Fields

    International Nuclear Information System (INIS)

    Alexander Dunaevsky; Yevgeny Raitses; Nathaniel J. Fisch

    2002-01-01

    Experimental investigations of a planar ferroelectric cathode in a transverse magnetic field up to 3 kGs are presented. It is shown that the transverse magnetic field affects differently the operation of ferroelectric plasma cathodes in ''bright'' and ''dark'' modes in vacuum. In the ''bright'' mode, when the surface plasma is formed, the application of the transverse magnetic field leads to an increase of the surface plasma density. In the ''dark'' mode, the magnetic field inhibits the development of electron avalanches along the surface, as it does similarly in other kinds of surface discharges in the pre-breakdown mode

  8. Cathode architectures for alkali metal / oxygen batteries

    Science.gov (United States)

    Visco, Steven J; Nimon, Vitaliy; De Jonghe, Lutgard C; Volfkovich, Yury; Bograchev, Daniil

    2015-01-13

    Electrochemical energy storage devices, such as alkali metal-oxygen battery cells (e.g., non-aqueous lithium-air cells), have a cathode architecture with a porous structure and pore composition that is tailored to improve cell performance, especially as it pertains to one or more of the discharge/charge rate, cycle life, and delivered ampere-hour capacity. A porous cathode architecture having a pore volume that is derived from pores of varying radii wherein the pore size distribution is tailored as a function of the architecture thickness is one way to achieve one or more of the aforementioned cell performance improvements.

  9. Studies on pulsed hollow cathode capillary discharges

    Energy Technology Data Exchange (ETDEWEB)

    Choi, P; Dumitrescu-Zoita, C; Larour, J; Rous, J [Ecole Polytechnique, 91 - Palaiseau (France). Lab. de Physique des Milieux Ionises; Favre, M; Moreno, J; Chuaqui, H; Wyndham, E [Pontificia Univ. Catolica de Chile, Santiago (Chile). Facultad de Fisica; Zambra, M [Comision Chilena de Energia Nuclear, Santiago (Chile); Wong, C S [Univ. of Malaya, Kuala Lumpur (Malaysia). Plasma Research Lab

    1997-12-31

    Preliminary results on radiation characteristics of pulsed hollow cathode capillary discharges are presented. The device combines the on axis electron beam assisted ionization capabilities of the transient hollow cathode discharge with a novel high voltage low inductance geometrical design, which integrates the local energy storage into the electrode system. A nanosecond regime high temperature plasma is produced in a long, high aspect ratio capillary, with light emission in the UV to XUV region. The discharge is operated from near vacuum to pressure in the 1000 mTorr range. (author). 2 figs., 7 refs.

  10. An Introduction To Reliability

    International Nuclear Information System (INIS)

    Park, Kyoung Su

    1993-08-01

    This book introduces reliability with definition of reliability, requirement of reliability, system of life cycle and reliability, reliability and failure rate such as summary, reliability characteristic, chance failure, failure rate which changes over time, failure mode, replacement, reliability in engineering design, reliability test over assumption of failure rate, and drawing of reliability data, prediction of system reliability, conservation of system, failure such as summary and failure relay and analysis of system safety.

  11. Cathode characterization system: preliminary results with (Ba,Sr,Ca) O coated cathodes

    International Nuclear Information System (INIS)

    Nono, M.C.A.; Goncalves, J.A.N.; Barroso, J.J.; Dallaqua, R.S.; Spassovsky, I.

    1993-01-01

    The performance of a cathode characterization system for studying the emission parameters of thermal electron emitters is reported. The system consists of vacuum chamber, power supplies and equipment for measuring and control. Measurements have been taken of the emission current as function of cathode temperature and anode voltage. Several (Ba, Sr) O coated cathodes were tested and the results have shown good agreement with Child's and Richardson's laws. The experimental work function is between 1.0 and 2.0 e V. All emission parameters measured are consistent with international literature data. (author)

  12. A Novel Cathode Material for Cathodic Dehalogenation of 1,1-Dibromo Cyclopropane Derivatives.

    Science.gov (United States)

    Gütz, Christoph; Selt, Maximilian; Bänziger, Markus; Bucher, Christoph; Römelt, Christina; Hecken, Nadine; Gallou, Fabrice; Galvão, Tomás R; Waldvogel, Siegfried R

    2015-09-28

    Leaded bronze turned out to be an excellent cathode material for the dehalogenation reaction of cyclopropanes without affecting the strained molecular entity. With this particular alloy, beneficial properties of lead cathodes are conserved, whereas the corrosion of cathode is efficiently suppressed. The solvent in the electrolyte determines whether a complete debromination reaction is achieved or if the process can be selectively stopped at the monobromo cyclopropane intermediate. The electroorganic conversion tolerates a variety of functional groups and can be conducted at rather complex substrates like cyclosporine A. This approach allows the sustainable preparation of cyclopropane derivatives. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Li- and Mn-Rich Cathode Materials: Challenges to Commercialization

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Jianming [Energy and Environmental Directorate, Pacific Northwest National Laboratory, 902 Battelle Boulevard Richland WA 99354 USA; Myeong, Seungjun [School of Energy and Chemical Engineering, Green Energy Materials Development Center, Ulsan National Institute of Science and Technology (UNIST), Korea 689-798; Cho, Woongrae [School of Energy and Chemical Engineering, Green Energy Materials Development Center, Ulsan National Institute of Science and Technology (UNIST), Korea 689-798; Yan, Pengfei [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 902 Battelle Boulevard Richland WA 99354 USA; Xiao, Jie [Energy and Environmental Directorate, Pacific Northwest National Laboratory, 902 Battelle Boulevard Richland WA 99354 USA; Wang, Chongmin [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 902 Battelle Boulevard Richland WA 99354 USA; Cho, Jaephil [School of Energy and Chemical Engineering, Green Energy Materials Development Center, Ulsan National Institute of Science and Technology (UNIST), Korea 689-798; Zhang, Ji-Guang [Energy and Environmental Directorate, Pacific Northwest National Laboratory, 902 Battelle Boulevard Richland WA 99354 USA

    2016-12-14

    The lithium- and manganese-rich (LMR) layered structure cathode exhibit one of the highest specific energy (~900 Wh kg-1) among all the cathode materials. However, the practical applications of LMR cathodes are still hindered by several significant challenges including voltage fade, large initial capacity loss, poor rate capability and limited cycle life. Herein, we review the recent progresses and understandings on the application of LMR cathode materials from practical point of view. Several key parameters of LMR cathodes that affect the LMR/graphite full cell operation are systematically analysed. These factors include the first cycle capacity loss, voltage fade, powder tap density, electrode density of LMR based cathode etc. New approaches to minimize the detrimental effect of these factors are highlighted in this work. We also provided the perspectives for the future research on LMR cathode materials, focusing on addressing the fundamental problems of LMR cathodes while always keeping practical considerations in mind.

  14. Reservoir Cathode for Electric Space Propulsion, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose a hollow reservoir cathode to improve performance in ion and Hall thrusters. We will adapt our existing reservoir cathode technology to this purpose....

  15. Impressed current cathodic protection of deep water structures

    Digital Repository Service at National Institute of Oceanography (India)

    Venkatesan, R.

    that the cathodic protection design approaches for shallow water may not be adequate for deeper water. This paper discusses on environmental factors encountered in deep water and their effect on cathodic protection behaviour of steel. Further, current CP design...

  16. Long Life Cold Cathodes for Hall effect Thrusters, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — An electron source incorporating long life, high current density cold cathodes inside a microchannel plate for use with ion thrusters is proposed. Cathode lifetime...

  17. Occurrence of heterotrophic and coliform bacteria in liquid hand soaps from bulk refillable dispensers in public facilities.

    Science.gov (United States)

    Chattman, Marisa; Gerba, Sheri L; Maxwell, Charles P

    2011-03-01

    The goal of the study discussed in this article was to determine the occurrence of heterotrophic and coliform bacteria in liquid soap from bulk refillable dispensers, obtained from restrooms in a variety of public facilities. A total of 541 samples was collected from five U.S. cities. Liquid soap from dispensers in public areas was found to contain heterotrophic and coliform bacterial numbers averaging more than 106 CFU/mL in 24.8% of the dispensers.

  18. Applications of cathodic protection for the protection of aqueous and soil corrosion of power plant components

    International Nuclear Information System (INIS)

    Sinha, A.K.; Mitra, A.K.; Bhakta, U.C.; Sanyal, S.K.

    2000-01-01

    Power plant components exposed to environments such as water and soil are susceptible to severe corrosion. Many times the effect of corrosion in power plant components can be catastrophic. The problem is aggravated for underground pipelines due to additional factors such as large network of pipelines, proximity to earth mat, high voltage transmission lines, corrosive chemicals, inadequate approach etc. Other components such as condenser water boxes, internals of pipelines, clarifier bridge structures, cooling water inlet gates and pipes etc. which are in continuous contact with water, are subjected to severe corrosion. The nature and locations of all such components are at places which are not accessible for routine maintenance and hence they require long term reliable protection against corrosion. Experience has shown that anti-corrosive coatings are inadequate in preventing corrosion and due to their location regular maintenance coatings are also not feasible. Under such circumstances the applications of cathodic protection provides a long term solution the design of cathodic protection, for such applications differs from the commonly employed cathodic protection for cross-country pipelines and submerged structures due to other complexities in the plant region and maintenance of the applied system. The present paper intends to discuss the applications of cathodic protection with suitable anti-corrosive coatings for protection of various power plant components and the specific features of each type of application. (author)

  19. Effective reprocessing of reusable dispensers for surface disinfection tissues – the devil is in the details

    Science.gov (United States)

    Kampf, Günter; Degenhardt, Stina; Lackner, Sibylle; Ostermeyer, Christiane

    2014-01-01

    Background: It has recently been reported that reusable dispensers for surface disinfection tissues may be contaminated, especially with adapted Achromobacter species 3, when products based on surface-active ingredients are used. Fresh solution may quickly become recontaminated if dispensers are not processed adequately. Methods: We evaluated the abilities of six manual and three automatic processes for processing contaminated dispensers to prevent recolonisation of a freshly-prepared disinfectant solution (Mikrobac forte 0.5%). Dispensers were left at room temperature for 28 days. Samples of the disinfectant solution were taken every 7 days and assessed quantitatively for bacterial contamination. Results: All automatic procedures prevented recolonisation of the disinfectant solution when a temperature of 60–70°C was ensured for at least 5 min, with or without the addition of chemical cleaning agents. Manual procedures prevented recontamination of the disinfectant solution when rinsing with hot water or a thorough cleaning step was performed before treating all surfaces with an alcohol-based disinfectant or an oxygen-releaser. Other cleaning and disinfection procedures, including the use of an alcohol-based disinfectant, did not prevent recolonisation. Conclusions: These results indicate that not all processes are effective for processing reusable dispensers for surface-disinfectant tissues, and that a high temperature during the cleaning step or use of a biofilm-active cleaning agent are essential. PMID:24653973

  20. Effective reprocessing of reusable dispensers for surface disinfection tissues – the devil is in the details

    Directory of Open Access Journals (Sweden)

    Kampf, Günter

    2014-03-01

    Full Text Available [english] Background: It has recently been reported that reusable dispensers for surface disinfection tissues may be contaminated, especially with adapted , when products based on surface-active ingredients are used. Fresh solution may quickly become recontaminated if dispensers are not processed adequately. Methods: We evaluated the abilities of six manual and three automatic processes for processing contaminated dispensers to prevent recolonisation of a freshly-prepared disinfectant solution (Mikrobac forte 0.5%. Dispensers were left at room temperature for 28 days. Samples of the disinfectant solution were taken every 7 days and assessed quantitatively for bacterial contamination. Results: All automatic procedures prevented recolonisation of the disinfectant solution when a temperature of 60–70°C was ensured for at least 5 min, with or without the addition of chemical cleaning agents. Manual procedures prevented recontamination of the disinfectant solution when rinsing with hot water or a thorough cleaning step was performed before treating all surfaces with an alcohol-based disinfectant or an oxygen-releaser. Other cleaning and disinfection procedures, including the use of an alcohol-based disinfectant, did not prevent recolonisation.Conclusions: These results indicate that not all processes are effective for processing reusable dispensers for surface-disinfectant tissues, and that a high temperature during the cleaning step or use of a biofilm-active cleaning agent are essential.

  1. LOW TEMPERATURE CATHODE SUPPORTED ELECTROLYTES

    Energy Technology Data Exchange (ETDEWEB)

    Harlan U. Anderson

    2000-03-31

    . However, they have the potential of being useful as an interface on the anode side of the electrolyte. NexTech has focused much of its effort during the past few months on establishing tape casting methods for porous LSM substrates. This work, performed under a separate DOE-funded program, involved tape casting formulations comprising LSM powders with bi-modal particle size distributions and fugitive pore forming additives. Sintered LSM substrates with porosities in the 30 to 40 vol% range, and pore sizes of 10 {approx} 20 microns have been prepared. In addition, tape casting formulations involving composite mixtures of LSM and Sm-doped ceria (SDC) have been evaluated. The LSM/SDC cathode substrates are expected to provide better performance at low temperatures. Characterization of these materials is currently underway.

  2. LOW TEMPERATURE CATHODE SUPPORTED ELECTROLYTES

    Energy Technology Data Exchange (ETDEWEB)

    Harlan U. Anderson; Wayne Huebner; Igor Kosacki

    2001-09-30

    This project has three main goals: Thin Films Studies, Preparation of Graded Porous Substrates and Basic Electrical Characterization and testing of Planar Single Cells. In this portion of study we have focused on producing YSZ films on porous LSM substrates. When using the polymer precursor there are a number of obstacles to overcome in order to form dense electrolyte layers on porous substrates (cathode or anode). Probably the most difficult problems are: (1) Extreme penetration of the polymer into the substrate must be prevented. (2) Shrinkage cracking must be avoided. (3) Film thickness in the 1 to 5{micro}m range must be achieved. We have demonstrated that cracking due to shrinkage involved during the elimination of solvents and organic matter and densification of the remaining oxide is not a problem as long as the resulting oxide film is < {approx} 0.15 {micro}m in thickness. We have also shown that we can make thicker films by making multiple depositions if the substrate is smooth (roughness {le} 0.1 {micro}m) and contains no surface pores > 0.2 {micro}m. The penetration of the polymer into the porous substrate can be minimized by increasing the viscosity of the polymer and reducing the largest pore at the surface of the substrate to {le} 0.2 {micro}m. We have shown that this can be done, but we have also shown that it is difficult to make dense films that are defect free with areas > 1 cm{sup 2}. This is because of the roughness of the substrate and the difficulty in making a substrate which does not have surface voids > 0.2 {micro}m. Thus the process works well for dense, smooth substrates for films < 1 {micro}m thick, but is difficult to apply to rough, porous surfaces and to make film thickness > 1 {micro}m. As a result of these problems, we have been addressing the issue of how to make dense films in the thickness range of 1 to 5 {micro}m on sintered porous substrates without introducing cracks and holes due to shrinkage and surface voids? These

  3. Polymer coatings as separator layers for microbial fuel cell cathodes

    KAUST Repository

    Watson, Valerie J.; Saito, Tomonori; Hickner, Michael A.; Logan, Bruce E.

    2011-01-01

    and increased coulombic efficiency (CE = 56-64%) relative to an uncoated cathode (29 ± 8%), but decreased power production (255-574 mW m-2). Electrochemical characterization of the cathodes ex situ to the MFC showed that the cathodes with the lowest charge

  4. Coating for lithium anode, thionyl chloride active cathode electrochemical cell

    Energy Technology Data Exchange (ETDEWEB)

    Catanzarite, V.O.

    1983-01-04

    Electrochemical power cells having a cathode current collector, a combination liquid active cathode depolarizer electrolyte solvent and an anode that forms surface compounds when in intimate contact with the liquid cathode are enhanced by the addition of a passivation limiting film contiguous to said anode. The passivating film is a member of the cyanoacrilate family of organic compounds.

  5. Coating for lithium anode, thionyl chloride active cathode electrochemical cell

    Energy Technology Data Exchange (ETDEWEB)

    Catanzarite, V.O.

    1981-10-20

    Electrochemical power cells having a cathode current collector, a combination liquid active cathode depolarizer electrolyte solvent and an anode that forms surface compounds when in intimate contact with the liquid cathode are enhanced by the addition of a passivation limiting film contiguous to said anode. The passivating film is a member of the cyanoacrilate family of organic compounds.

  6. Cold cathodes on ultra-dispersed diamond base

    International Nuclear Information System (INIS)

    Alimova, A.N.; Zhirnov, V.V.; Chubun, N.N.; Belobrov, P.I.

    1998-01-01

    Prospects of application of nano diamond powders for fabrication of cold cathodes are discussed.Cold cathodes based on silicon pointed structures with nano diamond coatings were prepared.The deposition technique of diamond coating was dielectrophoresis from suspension of nano diamond powder in organic liquids.The cathodes were tested in sealed prototypes of vacuum electronic devices

  7. Explosive-emission cathode fabricated using track method

    International Nuclear Information System (INIS)

    Akap'ev, G.N.; Korenev, S.A.

    1989-01-01

    Fabrication technique for large area multipoint cathodes is described. The technique is based on channels filling with metal in the ion-irradiated dielectric film producted after channel etching. It is shown, that cathode may be used under explosive emission conditions. Characteristics of diode with the mentioned type cathodes are measured

  8. RF Photoelectric injectors using needle cathodes

    International Nuclear Information System (INIS)

    Lewellen, J.W.; Brau, C.A.

    2003-01-01

    Photocathode RF guns, in various configurations, are the injectors of choice for both current and future applications requiring high-brightness electron beams. Many of these applications, such as single-pass free-electron lasers, require beams with high brilliance but not necessarily high charge per bunch. Field-enhanced photoelectric emission has demonstrated electron-beam current density as high as 10 10 A/m 2 , with a quantum efficiency in the UV that approaches 10% at fields on the order of 10 10 V/m. Thus, the use of even a blunt needle holds promise for increasing cathode quantum efficiency without sacrificing robustness. We present an initial study on the use of needle cathodes in photoinjectors to enhance beam brightness while reducing beam charge. Benefits include lower drive-laser power requirements, easier multibunch operation, lower emittance, and lower beam degradation due to charge-dependent effects in the postinjector accelerator. These benefits result from a combination of a smaller cathode emission area, greatly enhanced RF field strength at the cathode, and the charge scaling of detrimental postinjector linac effects, e.g., transverse wakefields and CSR

  9. RF Photoelectric injectors using needle cathodes

    Science.gov (United States)

    Lewellen, J. W.; Brau, C. A.

    2003-07-01

    Photocathode RF guns, in various configurations, are the injectors of choice for both current and future applications requiring high-brightness electron beams. Many of these applications, such as single-pass free-electron lasers, require beams with high brilliance but not necessarily high charge per bunch. Field-enhanced photoelectric emission has demonstrated electron-beam current density as high as 10 10 A/m 2, with a quantum efficiency in the UV that approaches 10% at fields on the order of 10 10 V/m. Thus, the use of even a blunt needle holds promise for increasing cathode quantum efficiency without sacrificing robustness. We present an initial study on the use of needle cathodes in photoinjectors to enhance beam brightness while reducing beam charge. Benefits include lower drive-laser power requirements, easier multibunch operation, lower emittance, and lower beam degradation due to charge-dependent effects in the postinjector accelerator. These benefits result from a combination of a smaller cathode emission area, greatly enhanced RF field strength at the cathode, and the charge scaling of detrimental postinjector linac effects, e.g., transverse wakefields and CSR.

  10. Cathode follower RF system with frequency modulation

    International Nuclear Information System (INIS)

    Irie, Y.; Yano, Y.; Kaneko, N.; Kobayashi, Y.

    1994-01-01

    A model RF system with a cathode follower was tested under frequency modulation in the 1-3.5 MHz range. The repetition rate was 40 Hz. The oscillation was stable, and the output impedance was measured to be around 20 ohm. (author)

  11. Renovation of the cathodic protection system

    NARCIS (Netherlands)

    Schuten, G.; Leggedoor, J.; Polder, R.B.; Peelen, W.H.A.

    2003-01-01

    The first system for Cathodic Protection of concrete in the Netherlands was applied to a one bicycle lane of a bridge suffering corrosion due to de-icing salt penetration in 1986. This CP system was based on the Ferex 100S conducting polymer cable anode in a cementitious overlay. Its functioning was

  12. Improved Rare-Earth Emitter Hollow Cathode

    Science.gov (United States)

    Goebel, Dan M.

    2011-01-01

    An improvement has been made to the design of the hollow cathode geometry that was created for the rare-earth electron emitter described in Compact Rare Earth Emitter Hollow Cathode (NPO-44923), NASA Tech Briefs, Vol. 34, No. 3 (March 2010), p. 52. The original interior assembly was made entirely of graphite in order to be compatible with the LaB6 material, which cannot be touched by metals during operation due to boron diffusion causing embrittlement issues in high-temperature refractory materials. Also, the graphite tube was difficult to machine and was subject to vibration-induced fracturing. This innovation replaces the graphite tube with one made out of refractory metal that is relatively easy to manufacture. The cathode support tube is made of molybdenum or molybdenum-rhenium. This material is easily gun-bored to near the tolerances required, and finish machined with steps at each end that capture the orifice plate and the mounting flange. This provides the manufacturability and robustness needed for flight applications, and eliminates the need for expensive e-beam welding used in prior cathodes. The LaB6 insert is protected from direct contact with the refractory metal tube by thin, graphite sleeves in a cup-arrangement around the ends of the insert. The sleeves, insert, and orifice plate are held in place by a ceramic spacer and tungsten spring inserted inside the tube. To heat the cathode, an insulating tube is slipped around the refractory metal hollow tube, which can be made of high-temperature materials like boron nitride or aluminum nitride. A screw-shaped slot, or series of slots, is machined in the outside of the ceramic tube to constrain a refractory metal wire wound inside the slot that is used as the heater. The screw slot can hold a single heater wire that is then connected to the front of the cathode tube by tack-welding to complete the electrical circuit, or it can be a double slot that takes a bifilar wound heater with both leads coming out

  13. Electronic vending machines for dispensing rapid HIV self-testing kits: a case study.

    Science.gov (United States)

    Young, Sean D; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert

    2014-02-01

    This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV self-testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: (1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, (2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and (3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits.

  14. [Dispensing prescriptions to persons affiliated with the Seguro Popular de Salud de México].

    Science.gov (United States)

    Garrido-Latorre, Francisco; Hernández-Llamas, Héctor; Gómez-Dantés, Octavio

    2008-01-01

    Measure and compare the percentage of prescriptions fully dispensed to persons with and without Popular Health Insurance (SPS in Spanish) who use ambulatory and general hospital services associated with the Mexico State Health Services (SESA in Spanish), and taking into account insurance status. SESA user satisfaction was also measured with respect to access to medication. Information for the study was taken from four surveys of SESA ambulatory and hospital units that included probabilistic samples with state representativity. Samples of ambulatory units were selected by stratification according to level of care and association to the SPS service network. The findings indicate that the percentage of prescriptions fully dispensed in SESA ambulatory units has improved, reaching approximately 90%, especially among those units offering services to persons affiliated with SPS. Nevertheless, these percentages continue to be lower than those of ambulatory units associated with social security institutions. Percentages of prescriptions fully dispensed have also improved in SESA hospital units, but continue to be relatively low. In nearly all states, as the percentage of prescriptions fully dispensed has increased, user satisfaction with access to medication has also improved. In 2006 more than 50% of the states had high levels of fully dispensed prescriptions among persons with SPS (> or =90%). The more significant problem exists among hospitals, since only 44% of users who received a prescription in SESA hospitals in 2006 had their prescriptions fully dispensed. This finding requires a review of SPS medication policies, which have favored highly prescribed low-cost medications at ambulatory services at the expense of higher cost and more therapeutically effective medications for hospital care, the latter having a greater impact on household budgets.

  15. Distance traveled and frequency of interstate opioid dispensing in opioid shoppers and nonshoppers.

    Science.gov (United States)

    Cepeda, M Soledad; Fife, Daniel; Yuan, Yingli; Mastrogiovanni, Greg

    2013-10-01

    Little is known about how far opioid shoppers travel or how often they cross state lines to fill their opioid prescriptions. This retrospective cohort study evaluated these measures for opioid shoppers and nonshoppers using a large U.S. prescription database. Patients with ≥3 opioid dispensings were followed for 18 months. A subject was considered a shopper when he or she filled overlapping opioid prescriptions written by >1 prescriber at ≥3 pharmacies. A heavy shopper had ≥5 shopping episodes. Outcomes assessed were distance traveled among pharmacies and number of states visited to fill opioid prescriptions. A total of 10,910,451 subjects were included; .7% developed any shopping behavior and their prescriptions accounted for 8.6% of all opioid dispensings. Shoppers and heavy shoppers were younger than the nonshoppers. Shoppers traveled a median of 83.8 miles, heavy shoppers 199.5 miles, and nonshoppers 0 miles. Almost 20% of shoppers or heavy shoppers, but only 4% of nonshoppers, visited >1 state. Shoppers traveled greater distances and more often crossed state borders to fill opioid prescriptions than nonshoppers, and their dispensings accounted for a disproportionate number of opioid dispensings. Sharing of data among prescription-monitoring programs will likely strengthen those programs and may decrease shopping behavior. This study shows that opioid shoppers travel greater distances and more often cross state borders to fill opioid prescriptions than nonshoppers, and their dispensings accounted for a disproportionate number of opioid dispensings. The findings support the need for data sharing among prescription-monitoring programs to deter opioid shopping behavior. Copyright © 2013 American Pain Society. Published by Elsevier Inc. All rights reserved.

  16. How can pharmacist remuneration systems in Europe contribute to generic medicine dispensing?

    Directory of Open Access Journals (Sweden)

    Dylst P

    2012-03-01

    Full Text Available Generic medicines can generate larger savings to health care budgets when their use is supported by incentives on both the supply-side and the demand-side. Pharmacists’ remuneration is one factor influencing the dispensing of generic medicines.Objective: The aim of this article is to provide an overview of different pharmacist remuneration systems for generic medicines in Europe, with a view to exploring how pharmacist remuneration systems can contribute to generic medicine dispensing.Methods: Data were obtained from a literature review, a Master thesis in Pharmaceutical Care at the Catholic University of Leuven and a mailing sent to all members of the Pharmaceutical Group of the European Union with a request for information about the local remuneration systems of community pharmacists and the possible existence of reports on discounting practices.Results: Pharmacists remuneration in most European countries consists of the combination of a fixed fee per item and a certain percentage of the acquisition cost or the delivery price of the medicines. This percentage component can be fixed, regressive or capped for very high-cost medicines and acts as a disincentive for dispensing generic medicines. Discounting for generic medicines is common practice in several European countries but information on this practice tends to be confidential. Nevertheless, data for Belgium, France, the Netherlands and United Kingdom indicated that discounting percentages varied from 10% to 70% of the wholesale selling price.Conclusion: Pharmacists can play an important role in the development of a generic medicines market. Pharmacists should not be financially penalized for dispensing generic medicines. Therefore, their remuneration should move towards a fee-for-performance remuneration instead of a price-dependent reimbursement which is currently used in many European countries. Such a fee-for-performance remuneration system provides a stimulus for generic medicines

  17. Progress of air-breathing cathode in microbial fuel cells

    Science.gov (United States)

    Wang, Zejie; Mahadevan, Gurumurthy Dummi; Wu, Yicheng; Zhao, Feng

    2017-07-01

    Microbial fuel cell (MFC) is an emerging technology to produce green energy and vanquish the effects of environmental contaminants. Cathodic reactions are vital for high electrical power density generated from MFCs. Recently tremendous attentions were paid towards developing high performance air-breathing cathodes. A typical air-breathing cathode comprises of electrode substrate, catalyst layer, and air-diffusion layer. Prior researches demonstrated that each component influenced the performance of air-breathing cathode MFCs. This review summarized the progress in development of the individual component and elaborated main factors to the performance of air-breathing cathode.

  18. Cathode Composition in a Saltwater Metal-Air Battery

    Directory of Open Access Journals (Sweden)

    William Shen

    2017-01-01

    Full Text Available Metal-air batteries consist of a solid metal anode and an oxygen cathode of ambient air, typically separated by an aqueous electrolyte. Here, simple saltwater-based models of aluminum-air and zinc-air cells are used to determine the differences between theoretical cell electric potentials and experimental electric potentials. A substantial difference is observed. It is also found that the metal cathode material is crucial to cell electric potential, despite the cathode not participating in the net reaction. Finally, the material composition of the cathode appears to have a more significant impact on cell potential than the submerged surface area of the cathode.

  19. Emission ability of La-Sc-Mo cathode

    International Nuclear Information System (INIS)

    Yang Jiancan; Nie Zuoren; Xi Xiaoli; Wang Yiman

    2004-01-01

    In this paper La-Sc-Mo cathode has been prepared and its electron emission ability was measured. This type of cathode shows good electron emission performance that the saturated current density is 6.74 A cm -1 and the work function is about 2.59 eV at 1300 deg. C, which is much lower than thoriated tungsten cathode (Th-W). So it is a potential cathode to replace the Th-W cathode with radioactive pollution. Surface analysis shows that good emission ability due to the 20 nm surplus La layer and the element Sc may do good to the La diffusion to the surface

  20. Explosive emission cathode on the base of carbon plastic fibre

    International Nuclear Information System (INIS)

    Korenev, S.A.; Baranov, A.M.; Kostyuchenko, S.V.; Chernenko, N.M.

    1989-01-01

    A fabrication process for explosive emission cathodes on the base of carbon plastic fibre of practically any geometrical shape and dimensions is developed. Experimental studies of electron beam current collection from cathodes, 2cm in diameter, at voltages across the diode of 10 and 150-250kV. It is shown that the ignition voltage for cathode plasma is ∼2kV at the interelectrode diode gap of 5mm and residual gas pressure of ∼5x10 -5 Torr. The carbon-fibre cathode, fabricated in this way, provides more stable current collection of an electron beam (without oscillations) than other cathodes

  1. Co-deposition of metallic actinides on a solid cathode

    Energy Technology Data Exchange (ETDEWEB)

    Limmer, S. J.; Williamson, M. A.; Willit, J. L. [Argonne National Laboratory, Argonne (United States)

    2008-08-15

    The amount of rare earth contamination that will be found in a co-deposit of actinides is a function of the type of cathode used. A non-alloying solid cathode will result in a significantly lower rare earth contamination in the actinide co-deposit than a liquid cadmium cathode. With proper control of the cathode potential vs. a stable reference electrode, co-deposition of uranium with other more electroactive metals has been demonstrated using a non-alloying solid cathode.

  2. Co-deposition of metallic actinides on a solid cathode

    International Nuclear Information System (INIS)

    Limmer, S. J.; Williamson, M. A.; Willit, J. L.

    2008-01-01

    The amount of rare earth contamination that will be found in a co-deposit of actinides is a function of the type of cathode used. A non-alloying solid cathode will result in a significantly lower rare earth contamination in the actinide co-deposit than a liquid cadmium cathode. With proper control of the cathode potential vs. a stable reference electrode, co-deposition of uranium with other more electroactive metals has been demonstrated using a non-alloying solid cathode

  3. Experimental research on time-resolved evolution of cathode plasma expansion velocity in a long pulsed magnetically insulated coaxial diode

    Science.gov (United States)

    Zhu, Danni; Zhang, Jun; Zhong, Huihuang; Ge, Xingjun; Gao, Jingming

    2018-02-01

    Unlike planar diodes, separate research of the axial and radial plasma expansion velocities is difficult for magnetically insulated coaxial diodes. Time-resolved electrical diagnostic which is based on the voltage-ampere characteristics has been employed to study the temporal evolution of the axial and radial cathode plasma expansion velocities in a long pulsed magnetically insulated coaxial diode. Different from a planar diode with a "U" shaped profile of temporal velocity evolution, the temporal evolution trend of the axial expansion velocity is proved to be a "V" shaped profile. Apart from the suppression on the radial expansion velocity, the strong magnetic field is also conducive to slowing down the axial expansion velocity. Compared with the ordinary graphite cathode, the carbon velvet and graphite composite cathode showed superior characteristics as judged by the low plasma expansion velocity and long-term electrical stability as a promising result for applications where long-pulsed and reliable operation at high power is required.

  4. Reliability and lifetime predictions of SLC klystrons

    International Nuclear Information System (INIS)

    Allen, M.A.; Callin, R.S.; Fowkes, W.R.; Lee, T.G.; Vlieks, A.E.

    1989-01-01

    The energy upgrade of SLAC, with the first of the new 67 MW SLAC Linear Collider (SLC) klystrons, began over four years ago. Today there are over 200 of these klystrons in operation. As a result, there is a wealth of klystron performance and failure information that enables reasonable predictions to be made on life expectancy and reliability. Data from initial tests, follow-up tests and daily operation monitoring on the accelerator is stored for analysis. Presented here are life expectancy predictions with particular emphasis on cathode life. Also, based on this data, the authors will discuss some of the principal modes of failure. 3 refs., 2 figs., 1 tab

  5. Reliability and lifetime predictions of SLC klystrons

    International Nuclear Information System (INIS)

    Allen, M.A.; Callin, R.S.; Fowkes, W.R.; Lee, T.G.; Vlieks, A.E.

    1989-03-01

    The energy upgrade of SLAC, with the first of the new 67 MW SLAC Linear Collider (SLC) klystrons, began over four years ago. Today there are over 200 of these klystrons in operation. As a result, there is a wealth klystron performance and failure information that enables reasonable predictions to be made on life expectancy and reliability. Data from initial tests, follow-up tests and daily operation monitoring on the accelerator is stores for analysis. Presented here are life expectancy predictions with particular emphasis on cathode life. Also, based on this data, we will discuss some of the principal modes of failure. 3 refs., 2 figs

  6. Polymer coatings as separator layers for microbial fuel cell cathodes

    KAUST Repository

    Watson, Valerie J.

    2011-03-01

    Membrane separators reduce oxygen flux from the cathode into the anolyte in microbial fuel cells (MFCs), but water accumulation and pH gradients between the separator and cathode reduces performance. Air cathodes were spray-coated (water-facing side) with anion exchange, cation exchange, and neutral polymer coatings of different thicknesses to incorporate the separator into the cathode. The anion exchange polymer coating resulted in greater power density (1167 ± 135 mW m-2) than a cation exchange coating (439 ± 2 mW m-2). This power output was similar to that produced by a Nafion-coated cathode (1114 ± 174 mW m-2), and slightly lower than the uncoated cathode (1384 ± 82 mW m-2). Thicker coatings reduced oxygen diffusion into the electrolyte and increased coulombic efficiency (CE = 56-64%) relative to an uncoated cathode (29 ± 8%), but decreased power production (255-574 mW m-2). Electrochemical characterization of the cathodes ex situ to the MFC showed that the cathodes with the lowest charge transfer resistance and the highest oxygen reduction activity produced the most power in MFC tests. The results on hydrophilic cathode separator layers revealed a trade off between power and CE. Cathodes coated with a thin coating of anion exchange polymer show promise for controlling oxygen transfer while minimally affecting power production. © 2010 Elsevier B.V. All rights reserved.

  7. Cathode R&D for Future Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Dowell, D.H.; /SLAC; Bazarov, I.; Dunham, B.; /Cornell U., CLASSE; Harkay, K.; /Argonne; Hernandez-Garcia; /Jefferson Lab; Legg, R.; /Wisconsin U., SRC; Padmore, H.; /LBL, Berkeley; Rao, T.; Smedley, J.; /Brookhaven; Wan, W.; /LBL, Berkeley

    2010-05-26

    This paper reviews the requirements and current status of cathodes for accelerator applications, and proposes a research and development plan for advancing cathode technology. Accelerator cathodes need to have long operational lifetimes and produce electron beams with a very low emittance. The two principal emission processes to be considered are thermionic and photoemission with the photocathodes being further subdivided into metal and semi-conductors. Field emission cathodes are not included in this analysis. The thermal emittance is derived and the formulas used to compare the various cathode materials. To date, there is no cathode which provides all the requirements needed for the proposed future light sources. Therefore a three part research plan is described to develop cathodes for these future light source applications.

  8. Cathode R and D for future light sources

    Energy Technology Data Exchange (ETDEWEB)

    Dowell, D.H., E-mail: dowell@slac.stanford.ed [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Bazarov, I.; Dunham, B. [Cornell University, Cornell Laboratory for Accelerator-Based Sciences and Education (CLASSE) Wilson Laboratory, Cornell University, Ithaca, NY 14853 (United States); Harkay, K. [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, Il 60439 (United States); Hernandez-Garcia, C. [Thomas Jefferson Laboratory, 12000 Jefferson Ave, Free Electron Laser Suite 19 Newport News, VA 23606 (United States); Legg, R. [University of Wisconsin, SRC, 3731 Schneider Dr., Stoughton, WI 53589 (United States); Padmore, H. [Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA 94720 (United States); Rao, T.; Smedley, J. [Brookhaven National Laboratory, 20 Technology Street, Bldg. 535B, Brookhaven National Laboratory Upton, NY 11973 (United States); Wan, W. [Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley, CA 94720 (United States)

    2010-10-21

    This paper reviews the requirements and current status of cathodes for accelerator applications, and proposes a research and development plan for advancing cathode technology. Accelerator cathodes need to have long operational lifetimes and produce electron beams with a very low emittance. The two principal emission processes to be considered are thermionic and photoemission with the photocathodes being further subdivided into metal and semi-conductors. Field emission cathodes are not included in this analysis. The thermal emittance is derived and the formulas used to compare the various cathode materials. To date, there is no cathode which provides all the requirements needed for the proposed future light sources. Therefore a three part research plan is described to develop cathodes for these future light source applications.

  9. Emission mechanism in high current hollow cathode arcs

    International Nuclear Information System (INIS)

    Krishnan, M.

    1976-01-01

    Large (2 cm-diameter) hollow cathodes have been operated in a magnetoplasmadynamic (MPD) arc over wide ranges of current (0.25 to 17 kA) and mass flow (10 -3 to 8 g/sec), with orifice current densities and mass fluxes encompassing those encountered in low current steady-state hollow cathode arcs. Detailed cathode interior measurements of current and potential distributions show that maximum current penetration into the cathode is about one diameter axially upstream from the tip, with peak inner surface current attachment up to one cathode diameter upstream of the tip. The spontaneous attachment of peak current upstream of the cathode tip is suggested as a criterion for characteristic hollow cathode operation. This empirical criterion is verified by experiment

  10. Frontiers of reliability

    CERN Document Server

    Basu, Asit P; Basu, Sujit K

    1998-01-01

    This volume presents recent results in reliability theory by leading experts in the world. It will prove valuable for researchers, and users of reliability theory. It consists of refereed invited papers on a broad spectrum of topics in reliability. The subjects covered include Bayesian reliability, Bayesian reliability modeling, confounding in a series system, DF tests, Edgeworth approximation to reliability, estimation under random censoring, fault tree reduction for reliability, inference about changes in hazard rates, information theory and reliability, mixture experiment, mixture of Weibul

  11. IoT for Real-Time Measurement of High-Throughput Liquid Dispensing in Laboratory Environments.

    Science.gov (United States)

    Shumate, Justin; Baillargeon, Pierre; Spicer, Timothy P; Scampavia, Louis

    2018-04-01

    Critical to maintaining quality control in high-throughput screening is the need for constant monitoring of liquid-dispensing fidelity. Traditional methods involve operator intervention with gravimetric analysis to monitor the gross accuracy of full plate dispenses, visual verification of contents, or dedicated weigh stations on screening platforms that introduce potential bottlenecks and increase the plate-processing cycle time. We present a unique solution using open-source hardware, software, and 3D printing to automate dispenser accuracy determination by providing real-time dispense weight measurements via a network-connected precision balance. This system uses an Arduino microcontroller to connect a precision balance to a local network. By integrating the precision balance as an Internet of Things (IoT) device, it gains the ability to provide real-time gravimetric summaries of dispensing, generate timely alerts when problems are detected, and capture historical dispensing data for future analysis. All collected data can then be accessed via a web interface for reviewing alerts and dispensing information in real time or remotely for timely intervention of dispense errors. The development of this system also leveraged 3D printing to rapidly prototype sensor brackets, mounting solutions, and component enclosures.

  12. 40 CFR Table 1 to Subpart Cccccc... - Applicability Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly...

    Science.gov (United States)

    2010-07-01

    ... Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Applicability Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000 Gallons of Gasoline or More...

  13. Development of a high-performance composite cathode for LT-SOFC

    Science.gov (United States)

    Lee, Byung Wook

    Solid Oxide Fuel Cell (SOFC) has drawn considerable attention for decades due to its high efficiency and low pollution, which is made possible since chemical energy is directly converted to electrical energy through the system without combustion. However, successful commercialization of SOFC has been delayed due to its high production cost mainly related with using high cost of interconnecting materials and the other structural components required for high temperature operation. This is the reason that intermediate (IT) or low temperature (LT)-SOFC operating at 600~800°C or 650°C and below, respectively, is of particular significance because it allows the wider selection of cheaper materials such as stainless steel for interconnects and the other structural components. Also, extended lifetime and system reliability are expected due to less thermal stress through the system with reduced temperature. More rapid start-up/shut-down procedure is another advantage of lowering the operating temperatures. As a result, commercialization of SOFC will be more viable. However, there exists performance drop with reduced operating temperature due to increased polarization resistances from the electrode electrochemical reactions and decreased electrolyte conductivity. Since ohmic polarization of the electrolyte can be significantly reduced with state-of-the art thin film technology and cathode polarization has more drastic effect on total SOFC electrochemical performance than anode polarization as temperature decreases, development of the cathode with high performance operating at IT or LT range is thus essential. On the other hand, chemical stability of the cathode and its chemical compatibility with the electrolyte should also be considered for cathode development since instability and incompatibility of the cathode will also cause substantial performance loss. Based on requirements of the cathode mentioned above, in this study, several chemico-physical approaches were

  14. A randomized-controlled trial with a Canadian electronic pill dispenser used to measure and improve medication adherence in patients with schizophrenia

    Directory of Open Access Journals (Sweden)

    Emmanuel eStip

    2013-08-01

    Full Text Available Objective: Medication adherence is extremely important in preventing relapse and lowering symptoms in schizophrenic patients. However, estimates show that nearly half of these patients have poor adherence. The Brief Adherence Rating Scale (BARS seems to be the most reliable tool assessing adherence in schizophrenia and shows that the antipsychotic adherence ratio (AAR is about 49.5 % in schizophrenia. The aim of the study was to test if an electronic pill dispenser named DoPill® improved AAR of schizophrenic patients. Furthermore, we compared AAR obtained by the DoPill® and the BARS, in order to verify whether the DoPill® provides reliable assessment of medication adherence. Methods: The DoPill® is a smart pill dispenser that beeps and flashes at the appropriate time of the day. Each of its 28 compartments is covered by a plastic lamina that, when taken off, sends a signal to the pharmacist. Patients were randomized to the DoPill® or Treatment As Usual group (TAU for six weeks. The BARS was used as a reference measure. Results: Forty-six percent of patients were deemed to be non-adherent with antipsychotic medication. The mean AAR was 67 % after six weeks. DoPill® recorded better AAR than some of those found in the literature and were lower than the BARS estimate we found. Conclusion: These results suggest that DoPill® is a valid tool that provides more reliable and objective data for the clinician about their patient’s adherence, than existing assessment tools like the BARS. Furthermore, the device may help patients successfully manage their medication regimen.

  15. A randomized controlled trial with a Canadian electronic pill dispenser used to measure and improve medication adherence in patients with schizophrenia.

    Science.gov (United States)

    Stip, Emmanuel; Vincent, Philippe D; Sablier, Juliette; Guevremont, Catherine; Zhornitsky, Simon; Tranulis, Constantin

    2013-01-01

    Medication adherence is extremely important in preventing relapse and lowering symptoms in schizophrenic patients. However, estimates show that nearly half of these patients have poor adherence. The Brief Adherence Rating Scale (BARS) seems to be the most reliable tool assessing adherence in schizophrenia and shows that the antipsychotic adherence ratio (AAR) is about 49.5% in schizophrenia. The aim of the study was to test if an electronic pill dispenser named DoPill(®) improved AAR of schizophrenic patients. Furthermore, we compared AAR obtained by the DoPill(®) and the BARS, in order to verify whether the DoPill(®) provides reliable assessment of medication adherence. The DoPill(®) is a smart pill dispenser that beeps and flashes at the appropriate time of the day. Each of its 28 compartments is covered by a plastic lamina that, when taken off, sends a signal to the pharmacist. Patients were randomized to the DoPill(®) or treatment as usual groups for 6 weeks. The BARS was used as a reference measure. Forty-six percent of patients were deemed to be non-adherent with antipsychotic medication. The mean AAR was 67% after 6 weeks. DoPill(®) recorded better AAR than some of those found in the literature and were lower than the BARS estimate we found. These results suggest that DoPill(®) is a valid tool that provides more reliable and objective data for the clinician about their patient's adherence, than existing assessment tools like the BARS. Furthermore, the device may help patients successfully manage their medication regimen.

  16. Homogeneous Crystallization of Micro-DispensedTIPS-Pentacene Using a Two-Solvent System toEnable Printed Inverters on Foil Substrates

    Directory of Open Access Journals (Sweden)

    Indranil Bose

    2015-08-01

    Full Text Available We report on a micro-dispensing system for 6,13-Bis(triisopropylsilylethynylpentacene (TIPS-pentacene to enable homogenous crystallization and uniform filmmorphology of the dispensed droplets using a two-solvent mixture along with the use of aninsulating binder. This solution composition results in a controlled evaporation of the dropletin ambient air such that the Marangoni flow counteracts the outward convective flow toenable uniform radial crystal growth from the edge towards the center of the drops.The consequence of this process is the high degree of uniformity in the crystallization of thedrops, which results in a reduction in the performance spread of the organic field effecttransistors (OFET created using this process. The addition of the insulating binder furtherimproves the reduction in the spread of the results as a trade-off to the reduction in mobilityof the transistors. The transfer curves of the OFETs show a tight grouping due to thecontrolled self-alignment of the TIPS-pentacene crystals; this repeatability was furtherhighlighted by fabricating p-type inverters with driver to load ratios of 8:1, wherein theoutput inverter curves were also grouped tightly while exhibiting a gain of greater than 4 inthe switching region. Therefore, the reliability and repeatability of this process justifies itsuse to enable large area solution-processed printed circuits at the cost of reduced mobility.

  17. New discharge tube with virtual cathode

    International Nuclear Information System (INIS)

    Seidelmann, L.; Aubrecht, L.

    2003-01-01

    Till this time known methods of the excitation of the discharge between electrodes are using either secondary or thermo emission of electrons by the cathode. Usually we speak about the self-maintained discharge. Lifetime of the cathode, that is shortened by the emission, limits in principle, the lifetime of the whole discharge tube. The discharge can, according to the present state of the art, be induced also by the inductive way. Arrangement for excitation of such discharge is rather expensive. The construction of the inductive excited discharge tube is considerably influenced by the necessity of the limitation of the losses in excitation magnetic circuits. Especially length of the discharge and pressure of the working gas are limited by the economic standpoints. Function of the discharge is always connected with unwanted electromagnetic radiation, whose restraint is expensive and represents limiting factor for arrangement of the discharge tube (Authors)

  18. Aspects of Chemical Composition and Somatic Cell count of Cow Milk Marketed at Dispensers

    Directory of Open Access Journals (Sweden)

    Mircea Valentin MUNTEAN

    2018-05-01

    Full Text Available Milk quality is influenced by many factors: lactation, fat, protein, lactose, number of somatic cells. In order to process raw milk and compare with criteria of quality and food safety the Regulation of European Parliament and the council no. 853/2004. Analysing the total number of somatic cells (SCC in the period July-August 2017 it is noted that in case of samples collected from first automatic milk dispenser exceed 2 times the maximum admissible values and the samples collected from second automatic milk dispenser are up to the maximum allowable values which show that milking hygiene and animal health are at the European standards required. Analysis of fat content for both cases indicates that it is within the standard values for cow's milk and fat variations for DM1 samples are very low at temperatures above 30 degrees Celsius which shows that high temperatures do not influence these parameters. The biological material study was represented analysed by 30 samples of milk from only two cow milk dispensers functional located in this period in Cluj-Napoca city. These samples were collected at the same time period during July-August months. The aim of present study is to determine whether milk marketed through dispensers under the high temperature conditions specific to this period is affected in terms of qualitative parameter analysis.

  19. The knowledge of emergency contraception and dispensing practices of Patent Medicine Vendors in South West Nigeria.

    Science.gov (United States)

    Fayemi, Mojisola M; Oduola, Olufemi L; Ogbuji, Queen C; Osinowo, Kehinde A; Oyewo, Adejoke E; Osiberu, Olabimpe M

    2010-09-01

    Patent Medicine Vendors (PMVs) can play a critical role in increasing access to emergency contraceptive pills (ECPs) in developing countries, but few studies have examined their knowledge and dispensing practices. Using cluster sampling, the authors selected and interviewed 97 PMVs (60.8 per cent female) in Oyo and Ogun States of Nigeria to assess their knowledge, dispensing practices, and referral for ECPs. About one-third (27.8 per cent) of respondents were not aware of ECPs, and only half knew that ECPs could prevent pregnancy. Forty per cent had ever dispensed ECPs. Reasons proffered by those who do not dispense ECPs included barriers from the State Ministry of Health, police, other regulatory agencies, and religious beliefs. Only 50.5 per cent have referral arrangements for clients. Strategies to increase access to ECPs through PMVs include training on counseling techniques and referral, effective government regulation, and community involvement. Where unsafe abortion is a major cause of maternal mortality, these strategies offer protection for many women in the future.

  20. Validation of a proxy for estrogen receptor status in breast cancer patients using dispensing data.

    Science.gov (United States)

    Srasuebkul, Preeyaporn; Dobbins, Timothy A; Pearson, Sallie-Anne

    2014-06-01

    To assess the performance of a proxy for estrogen receptor (ER) status in breast cancer patients using dispensing data. We derived our proxy using 167 patients. ER+ patients had evidence of at least one dispensing record for hormone therapy during the lookback period, irrespective of diagnosis date and ER- had no dispensing records for hormone therapy during the period. We validated the proxy against our gold standard, ER status from pathology reports or medical records. We assessed the proxy's performance using three lookback periods: 4.5 years, 2 years, 1 year. More than half of our cohort (62%) were >50 years, 54% had stage III/IV breast cancer at recruitment, (46%) were diagnosed with breast cancer in 2009 and 23% were diagnosed before 2006. Sensitivity and specificity were high for the 4.5 year lookback period (93%, 95% CI: 86-96%; and 95%: 83-99%), respectively) and remained high for the 2-year lookback period (91%: 84-95%; and 95%: 83-99%). Sensitivity decreased (83%: 75.2-89%) but specificity remained high (95%: 83-99%) using the 1-year lookback period and the period is long enough to allow sufficient time for hormone therapy to be dispensed. Our proxy accurately infers ER status in studies of breast cancer treatment based on secondary health data. The proxy is most robust with a minimum lookback period of 2 years. © 2012 Wiley Publishing Asia Pty Ltd.

  1. Efficacy of a Feed Dispenser for Horses in Decreasing Cribbing Behaviour

    Directory of Open Access Journals (Sweden)

    Silvia Mazzola

    2016-01-01

    Full Text Available Cribbing is an oral stereotypy, tends to develop in captive animals as a means to cope with stress, and may be indicative of reduced welfare. Highly energetic diets ingested in a short time are one of the most relevant risk factors for the development of cribbing. The aim of this study was to verify whether feeding cribbing horses through a dispenser that delivers small quantities of concentrate when activated by the animal decreases cribbing behaviour, modifies feeding behaviour, or induces frustration. Ten horses (mean age 14 y, balanced for sex, breed, and size (mean height 162 cm, were divided into two groups of 5 horses each: Cribbing and Control. Animals were trained to use the dispenser and videorecorded continuously for 15 consecutive days from 1 h prior to feeding to 2 h after feeding in order to measure their behaviours. The feed dispenser, Quaryka®, induced an increase in time necessary to finish the ration in both groups of horses (P<0.05. With Quaryka, cribbers showed a significant reduction of time spent cribbing (P<0.05. After removal of the feed dispenser (Post-Quaryka, cribbing behaviour significantly increased. The use of Quaryka may be particularly beneficial in horses fed high-energy diets and ingesting the food too quickly.

  2. Microbiological quality of drinking water from dispensers in roadside restaurants of Bangladesh.

    Science.gov (United States)

    Moniruzzaman, M; Akter, S; Islam, M A; Mia, Z

    2011-01-15

    The microbiological status of water from dispensers in different roadside restaurants of Dhaka city and Savar area was analyzed in this study. Seven samples from Dhaka and 8 samples of Savar were checked. The heterotrophic plate count was in a range of 1.0 x 10(3) CFU mL(-1) to 2.0 x 10(4) CFU mL(-1) (from new bottles), 1.0 x 10(3) to 1.5 x 10(4) CFU mL(-1) (after dispensation), and 1.5 x 10(3) CFU mL(-1) to 1.0 x l0(5) CFU mL(-1) (from serving glass). In several of the samples, the heterotrophic plate count was higher than the count in water from new bottle or after dispensation, suggesting added contamination from the serving glass. 80% of the samples were contaminated with total and fecal coliform bacteria, which render these waters unacceptable for human consumption. The samples were found to contain gram negative bacteria like E coli, Shigella sp., Klebsiella sp., Enterobacter sp., Pseudomonas sp., and Salmonella sp., which are potential pathogens and thus pose a serious threat to public health. This study elucidates the importance of monitoring the bottling companies and the restaurants and put them under strict regulations to prevent future outbreak of any water borne diseases caused by consumption of dispensed water.

  3. Smart DNA Fabrication Using Sound Waves: Applying Acoustic Dispensing Technologies to Synthetic Biology.

    Science.gov (United States)

    Kanigowska, Paulina; Shen, Yue; Zheng, Yijing; Rosser, Susan; Cai, Yizhi

    2016-02-01

    Acoustic droplet ejection (ADE) technology uses focused acoustic energy to transfer nanoliter-scale liquid droplets with high precision and accuracy. This noncontact, tipless, low-volume dispensing technology minimizes the possibility of cross-contamination and potentially reduces the costs of reagents and consumables. To date, acoustic dispensers have mainly been used in screening libraries of compounds. In this paper, we describe the first application of this powerful technology to the rapidly developing field of synthetic biology, for DNA synthesis and assembly at the nanoliter scale using a Labcyte Echo 550 acoustic dispenser. We were able to successfully downscale PCRs and the popular one-pot DNA assembly methods, Golden Gate and Gibson assemblies, from the microliter to the nanoliter scale with high assembly efficiency, which effectively cut the reagent cost by 20- to 100-fold. We envision that acoustic dispensing will become an instrumental technology in synthetic biology, in particular in the era of DNA foundries. © 2015 Society for Laboratory Automation and Screening.

  4. PMD: designing a portable medicine dispenser for persons suffering from Alzheimer’s disease

    NARCIS (Netherlands)

    de Beer, Roel C.J.M.; Keijers, R.; Shahid, S.; Al Mahmud, A.; Mubin, O.

    2010-01-01

    In this paper we present the user-centred design of a medicine dispenser for persons suffering from Alzheimer’s disease. The prototype was evaluated in two phases with two caregivers and two Alzheimer’s patients. Caregivers evaluated the device positively. The Alzheimer’s patients faced usability

  5. Understanding vs. Competency: The Case of Accuracy Checking Dispensed Medicines in Pharmacy

    Science.gov (United States)

    James, K. Lynette; Davies, J. Graham; Kinchin, Ian; Patel, Jignesh P.; Whittlesea, Cate

    2010-01-01

    Ensuring the competence of healthcare professionals' is core to undergraduate and post-graduate education. Undergraduate pharmacy students and pre-registration graduates are required to demonstrate competence at dispensing and accuracy checking medicines. However, competence differs from understanding. This study determined the competence and…

  6. Exceptional circumstance drug dispensing: history and expenditures of the Brazilian Ministry of Health.

    Science.gov (United States)

    Carias, Claudia Mezleveckas; Vieira, Fabíola Sulpino; Giordano, Carlos V; Zucchi, Paola

    2011-04-01

    To describe the technical aspects of the Exceptional Circumstance Drug Dispensing Program of the Brazilian Ministry of Health, especially with respect to the cost of dispensed medication. Technical information was obtained from the ordinances that regulate the Program. Expenditure from 2000 to 2007 was obtained from the Sistema Único de Saúde's (Unified Healthcare System) Outpatient Information System. All drugs dispensed between 1993 and 2009 and the amount and cost of each procedure were evaluated, based on information from the high-complexity procedure authorization of each of the country's states. The Program changed with the increase in the number of pharmacological agents and presentations distributed by, and the number of diseases contemplated in the program. In 1993, the program distributed 15 pharmacological agents in 31 distinct presentations. This number increased to 109 agents in 243 presentations in 2009. Total Ministry of Health expenditure with medications was R$1,410,181,600.74 in 2007, almost twice the amount spent in 2000, R$684,975,404.43. Diseases whose expenditure increased in the period included chronic renal insufficiency, transplantation, and hepatitis C. The Exceptional Circumstance Drug Dispensing Program is in constant transformation, aimed at building instruments and strategies that can ensure and expand access to medication among the population. Alternatives should be sought to decrease the financial impact of the Program to a level that does not impact other sectors of the health care system, given the high cost associated with novel interventions.

  7. A systematic approach for the location of hand sanitizer dispensers in hospitals.

    Science.gov (United States)

    Cure, Laila; Van Enk, Richard; Tiong, Ewing

    2014-09-01

    Compliance with hand hygiene practices is directly affected by the accessibility and availability of cleaning agents. Nevertheless, the decision of where to locate these dispensers is often not explicitly or fully addressed in the literature. In this paper, we study the problem of selecting the locations to install alcohol-based hand sanitizer dispensers throughout a hospital unit as an indirect approach to maximize compliance with hand hygiene practices. We investigate the relevant criteria in selecting dispenser locations that promote hand hygiene compliance, propose metrics for the evaluation of various location configurations, and formulate a dispenser location optimization model that systematically incorporates such criteria. A complete methodology to collect data and obtain the model parameters is described. We illustrate the proposed approach using data from a general care unit at a collaborating hospital. A cost analysis was performed to study the trade-offs between usability and cost. The proposed methodology can help in evaluating the current location configuration, determining the need for change, and establishing the best possible configuration. It can be adapted to incorporate alternative metrics, tailored to different institutions and updated as needed with new internal policies or safety regulation.

  8. Long pulse, plasma cathode E-gun

    International Nuclear Information System (INIS)

    Goebel, D.M.; Schumacher, R.W.; Watkins, R.M.

    1993-01-01

    A unique, long-pulse E-gun has been developed for high-power tube applications. The Hollow-Cathode-Plasma (HCP) E-gun overcomes the limitations of conventional thermionic-cathode guns that have limited current density (typically ≤ 10 A/cm 2 ) or field-emission guns that offer high current density but suffer from short pulsewidth capability (typically 50 A/cm 2 ), long-pulse operation without gap closure, and also requires no cathode-heater power. The gun employs a low-pressure glow discharge inside a hollow cathode (HC) structure to provide a stable, uniform plasma surface from which a high current-density electron beam can be extracted. The plasma density is controlled by a low-voltage HC discharge pulser to produce the desired electron current density at the first grid of a multi-grid accelerator system. A dc high-voltage electron-beam supply accelerates the electrons across the gap, while the HC pulser modulates the beam current to generate arbitrary pulse waveforms. The electron accelerator utilizes a multi-aperture array that produces a large area, high perveance (>35 μpervs) beam consisting initially of many individual beamlets. The E-beam is normally operated without an applied magnetic field in the ion-focused regime, where the plasma produced by beam ionization of a background gas space-charge neutralizes the beam, and the Bennett self-pinch compresses the beamlets and increases the current density. The self-pinched beam has been observed to propagate over a meter without beam breakup or instabilities. The HCP E-gun has been operated at voltages up to 150 kV, currents up to 750 A, and pulse lengths of up to 120 μsec

  9. Bi-metallic nanoparticles as cathode electrocatalysts

    Science.gov (United States)

    Lu, Jun; Amine, Khalil; Wang, Xiaoping; Luo, Xiangyi; Myers, Deborah J.

    2018-03-27

    A lithium-air battery cathode catalyst includes core-shell nanoparticles on a carbon support, wherein: a core of the core-shell nanoparticles is platinum metal; and a shell of the core-shell nanoparticles is copper metal; wherein: the core-shell nanoparticles have a weight ratio of the copper metal to the platinum metal from about 4% to about 6% copper to from about 2% to about 12% platinum, with a remaining percentage being the carbon support.

  10. Cathodic protection of a nuclear fuel facility

    International Nuclear Information System (INIS)

    Corbett, R.A.

    1989-01-01

    This article discusses corrosion on buried process piping and tanks at a nuclear fuel facility and the steps taken to design a system to control underground corrosion. Collected data have indicated that cathodic protection is needed to supplement the regular use of high-integrity, corrosion-resistant coatings; wrapping systems; special backfills; and insulation material. The technical approach discussed in this article is generally applicable to other types of power and/or industrial plants with extensive networks of underground steel piping

  11. Cathode readout with stripped resistive drift tubes

    International Nuclear Information System (INIS)

    Bychkov, V.N.; Kekelidze, G.D.; Novikov, E.A.; Peshekhonov, V.D.; Shafranov, M.D.; Zhiltsov, V.E.

    1995-01-01

    A straw tube drift chamber prototype has been constructed and tested. The straw tube material is mylar film covered with a carbon layer with a resistivity of 0.5, 30 and 70 kΩ/□. Both the anode wire and the cathode strip signals were detected to study the behaviour of the chamber in the presence of X-ray ionization. The construction and the results of the study are presented. (orig.)

  12. Cathode readout with stripped resistive drift tubes

    Science.gov (United States)

    Bychkov, V. N.; Kekelidze, G. D.; Novikov, E. A.; Peshekhonov, V. D.; Shafranov, M. D.; Zhiltsov, V. E.

    1995-12-01

    A straw tube drift chamber prototype has been constructed and tested. The straw tube material is mylar film covered with a carbon layer with a resistivity of 0.5, 30 and 70 kΩ/□. Both the anode wire and the cathode strip signals were detected to study the behaviour of the chamber in the presence of X-ray ionization. The construction and the results of the study are presented.

  13. Surface contamination of counting tools after mock dispensing of cyclophosphamide in a simulated outpatient pharmacy.

    Science.gov (United States)

    Chaffee, Bruce W; Lander, Michael J; Christen, Catherine; Redic, Kimberly A

    2018-01-01

    Purpose The primary aim was to determine if dispensing of cyclophosphamide tablets resulted in accumulated residue on pharmacy counting tools during a simulated outpatient dispensing process. Secondary objectives included determining if cyclophosphamide contamination exceeded a defined threshold level of 1 ng/cm 2 and if a larger number of prescriptions dispensed resulted in increased contamination. Methods Mock prescriptions of 40 cyclophosphamide 50 mg tablets were counted on clean trays in three scenarios using a simulated outpatient pharmacy after assaying five cleaned trays as controls. The three scenarios consisted of five simulated dispensings of one, three, or six prescriptions dispensed per scenario. Wipe samples of trays and spatulas were collected and assayed for all trays, including the five clean trays used as controls. Contamination was defined as an assayed cyclophosphamide level at or above 0.001 ng/cm 2 and levels above 1 ng/cm 2 were considered sufficient to cause risk of human uptake. Mean contamination for each scenario was calculated and compared using one-way analysis of variance. P-values of contamination on trays used to count one, three, and six cyclophosphamide prescriptions was 0.51 ± 0.10 (p=0.0003), 1.02 ± 0.10 (p contamination. Increasing the number of prescriptions dispensed from 1 to 3, 1 to 6, and 3 to 6 counts increased contamination by 0.51 ± 0.15 (p = 0.0140), 1.31 + 0.15 (p contaminates pharmacy counting tools, and an increased number of prescriptions dispensed correlates with increased level of contamination. Counting out three or more prescriptions leads to trays having contamination that surpasses the threshold at which worker exposure may be increased. Pharmacies should consider devoting a separate tray to cyclophosphamide tablets, as cross-contamination could occur with other drugs and the efficacy of decontamination methods is unclear. Employee exposure could be minimized with the use

  14. A definitive criterion for cathodic protection

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, Roger [Cathodic Protection Network International Ltd., Reading (United Kingdom)

    2009-07-01

    The corrosion reaction is defined using the Pourbaix Diagram and includes consideration of the pH, temperature, pressure, nobility of the metal and conductivity of the electrolyte. The passive zone can be established in a laboratory by creating a closed circuit condition in which the voltages can be measured. Natural corrosion cells occurring in simple conditions can be evaluated for the purpose of monitoring the performance of cathodic protection. Metal pipelines are complex networks of conductors submerged in electrolyte of infinitely variable qualities. The present method used to ascertain the effectiveness of cathodic protection has many inherent errors and results in costly and unpredictable corrosion failures. An electrode has been devised to define the exact electrical status of the corrosion reaction at its location. The design allows a closed circuit measurement of the corrosion current that can determine whether or not corrosion has been stopped by cathodic protection. This has allowed the development of software that can calculate the condition and corrosion status throughout a network of pipelines, using electrical circuit analysis common in the electronics industry. (author)

  15. Through-Silicon-Via Underfill Dispensing for 3D Die/Interposer Stacking

    Science.gov (United States)

    Le, Fuliang

    The next generation packaging keeps up with the increased demands of functionality by using the third dimension. 3D chip stacking with TSVs has been identified as one of the major technologies to achieve higher silicon density and shorter interconnection. In order to protect solder interconnections from hostile environments and redistribute thermal stress caused by CTE mismatch, underfill should be applied for the under-chip spaces. In this study, TSV underfill dispensing is introduced to address the underfill challenge for 3D chip stacks. The material properties are first measured and the general trend indicates viscosity and contact angle dropping significantly with an increase in temperature, and surface tension falling slightly as the temperature increases. Underfill should assure a complete encapsulation, avoiding excessive filling time that can result in substantial manufacturing delays. Typically, the inflows for TSV underfill can be free droplets or a constant flow rate. For a constant inflow, the underfill flow is driven by pressure difference and the filling time is governed by flow radius, gap clearance and the constant flow rate. For an inflow of free droplets, the underfill flow is driven by capillary action and the filling time is related to viscosity, flow radius, gap clearance, surface tension, contact angle and TSV size. In general, TSV underfill dispensing with a constant inflow has much shorter filling time than dispensing with an inflow of free droplets. TSV underfill dispensing on a 3D chip stack may induce the risk of an edge flood failure. In order to avoid an edge flood, fluid pressure around the sidewalls of a 3D chip stack cannot exceed limit equilibrium pressure. For TSV dispensing with free droplets, there is no risk of forming an edge flood. However, for a constant inflow, TSV dispensing should be carefully controlled to avoid excessive pressure. Besides, it is suggested that the TSVs in stacked chips be aligned in the vertical

  16. Isolation of Raoultella planticola from refillable antimicrobial liquid soap dispensers in a dental setting.

    Science.gov (United States)

    Momeni, Stephanie S; Tomlin, Nancy; Ruby, John D

    2015-04-01

    Liquid antimicrobial soaps are commonly used in the dental health care setting for hand washing to minimize the potential spread of infectious agents to health care workers and patients. The purpose of the current study was to evaluate possible bacterial contamination of antimicrobial liquid soap dispensers located in 2 institutional comprehensive dental care clinics. Fourteen soap dispensers and 16 original stock containers were sampled. A 1-milliliter aliquot was diluted in 10 mL of phosphate buffer (Tween-80; Acros). Serial dilutions were plated in duplicate on neutralizing agar and incubated for 7 days. Molecular identification was performed using 500 base pair comparisons of 16S ribosomal ribonucleic acid sequencing. Taq polymerase chain reaction was performed with sequence-specific primers for Raoultella species. Bacterial growth was observed at 18 hours for 57% (8 of 14) of soap dispenser samples. Bacterial densities ranged from 4 × 10(2) to 6 × 10(9) colony-forming units per milliliter. Original commercial containers exhibited no growth. Isolates were identified as Raoultella (Klebsiella) planticola. This is the first study to the authors' knowledge indicating recovery of R. planticola from antimicrobial liquid soap dispensers. R. planticola is a recognized environmental opportunistic pathogen that potentially poses a health concern. These findings indicate compliance problems with infection prevention recommendations and support the US Centers for Disease Control and Prevention's recommendation that dispensers should not be topped off. High bacterial loads of R. planticola are inconsistent with infection control practices and are a concern because transmission and possible infection to the health care worker or the patient may occur. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  17. The expected and unexpected benefits of dispensing the exact number of pills.

    Science.gov (United States)

    Treibich, Carole; Lescher, Sabine; Sagaon-Teyssier, Luis; Ventelou, Bruno

    2017-01-01

    From November 2014 to November 2015, an experiment in French community pharmacies replaced traditional pre-packed boxes by per-unit dispensing of pills in the exact numbers prescribed, for 14 antibiotics. A cluster randomised control trial was carried out in 100 pharmacies. 75 pharmacies counted out the medication by units (experimental group), the other 25 providing the treatment in the existing pharmaceutical company boxes (control group). Data on patients under the two arms were compared to assess the environmental, economic and health effects of this change in drug dispensing. In particular, adherence was measured indirectly by comparing the number of pills left at the end of the prescribed treatment. Out of the 1185 patients included during 3 sessions of 4 consecutive weeks each, 907 patients experimented the personalized delivery and 278 were assigned to the control group, consistent with a 1/3 randomization-rate at the pharmacy level. 80% of eligible patients approved of the per-unit dispensing of their treatment. The initial packaging of the drugs did not match with the prescription in 60% of cases and per-unit dispensing reduced by 10% the number of pills supplied. 13.1% of patients declared that they threw away pills residuals instead of recycling-no differences between groups. Finally, per-unit dispensing appeared to improve adherence to antibiotic treatment (marginal effect 0.21, IC 95, 0.14-0.28). Supplying antibiotics per unit is not only beneficial in terms of a reduced number of pills to reimburse or for the environment (less pills wasted and non-recycled), but also has a positive and unexpected impact on adherence to treatment, and thus on both individual and public health.

  18. Population prevalence of high dose paracetamol in dispensed paracetamol/opioid prescription combinations: an observational study

    Science.gov (United States)

    2012-01-01

    Background Paracetamol (acetaminophen) is generally considered a safe medication, but is associated with hepatotoxicity at doses above doses of 4.0 g/day, and even below this daily dose in certain populations. Methods The Nova Scotia Prescription Monitoring Program (NSPMP) in the Canadian province of Nova Scotia is a legislated organization that collects dispensing information on all out-of-hospital prescription controlled drugs dispensed for all Nova Scotia residents. The NSPMP provided data to track all paracetamol/opioids redeemed by adults in Nova Scotia, from July 1, 2005 to June 30, 2010. Trends in the number of adults dispensed these prescriptions and the numbers of prescriptions and tablets dispensed over this period were determined. The numbers and proportions of adults who filled prescriptions exceeding 4.0 g/day and 3.25 g/day were determined for the one-year period July 1, 2009 to June 30, 2010. Data were stratified by sex and age (paracetamol/opioid prescription was lower in each successive one-year period. From July 2009 to June 2010, one in 12 adults (n = 59,197) filled prescriptions for over 13 million paracetamol/opioid tablets. Six percent (n = 3,786) filled prescriptions that exceeded 4.0 g/day and 18.6% (n = 11,008) exceeded 3.25 g/day of paracetamol at least once. These findings exclude non-prescription paracetamol and paracetamol–only prescribed medications. Conclusions A substantial number of individuals who redeem prescriptions for paracetamol/opioid combinations may be at risk of paracetamol-related hepatotoxicity. Healthcare professionals must be vigilant when prescribing and dispensing these medications in order to reduce the associated risks. PMID:22709372

  19. Twenty-year trends in benzodiazepine dispensing in the Australian population.

    Science.gov (United States)

    Islam, M M; Conigrave, K M; Day, C A; Nguyen, Y; Haber, P S

    2014-01-01

    Considerable concern has been expressed about overprescribing of benzodiazepines and related harms. Past analyses have relied on World Health Organization-defined daily doses (DDD) which are sometimes out of keeping with clinical usage. This study examines 20-year (1992-2011) trends of benzodiazepine dispensing in Australia using both DDD and Ashton equivalent dose. Data from the Drug Utilisation Sub-Committee and the Pharmaceutical Benefits Scheme (PBS) website were analysed. Trends in number of prescriptions, DDD/1000 people/day and DDD/prescription were examined over time, and between states/territories. In the 20-year period, 174 080 904 scripts were recorded, with temazepam the most dispensed benzodiazepine (35% of scripts), followed by diazepam (23%). Overall recorded utilisation fell from 27.7 DDD/1000 people/day in 1992 to 20.8 in 2011 (24.9% decrease). There were striking changes in use of individual benzodiazepines over time, with reductions in oxazepam and flunitrazepam and dramatic increases in alprazolam. Since 1998, there has been a steady increase, albeit modest, in per script DDD. The DDD/1000 people/day for items dispensed through PBS/Repatriaton-PBS was highest in Tasmania and lowest in Northern Territory. Despite a modest overall decline in the amount of benzodiazepine dispensed, the level of use is still likely to reflect relative over-prescribing given the paucity of accepted indications for long-term use. Since 1998, there was a polynomial increase in quantity dispensed per script. The WHO-defined DDD for clonazepam seems inappropriate and could impede monitoring of its abuse. Other problems include lack of national data for medications not subsidised on PBS/Repatriation PBS. A broad policy approach is required, not one which targets only one particular benzodiazepine. © 2013 The Authors; Internal Medicine Journal © 2013 Royal Australasian College of Physicians.

  20. System Reliability Engineering

    International Nuclear Information System (INIS)

    Lim, Tae Jin

    2005-02-01

    This book tells of reliability engineering, which includes quality and reliability, reliability data, importance of reliability engineering, reliability and measure, the poisson process like goodness of fit test and the poisson arrival model, reliability estimation like exponential distribution, reliability of systems, availability, preventive maintenance such as replacement policies, minimal repair policy, shock models, spares, group maintenance and periodic inspection, analysis of common cause failure, and analysis model of repair effect.

  1. Surface studies of thermionic cathodes and the mechanism of operation of an impregnated tungsten cathode

    International Nuclear Information System (INIS)

    Forman, R.

    1976-09-01

    The surface properties of conventional impregnated cathodes were investigated by the use of Auger spectroscopy and work function measurements, and these were compared with a synthesized barium- or barium oxide coated tungsten surface. The barium- and barium oxide coated surfaces were prepared by evaporating barium onto a tungsten surface that can be heated to elevated temperatures. Multilayer or monolayer coverages can be investigated using this technique. The results of this study show that the surface of an impregnated tungsten cathode is identical to that observed for a synthesized monolayer or partial monolayer of barium on partially oxidized tungsten, using the criteria of identical Auger patterns and work functions. Desorption measurements of barium from a tungsten surface were also made. These results in conjunction with Auger and work function data were interpreted to show that throughout most of its life an impregnated cathode operating in the range of 1100 C has a partial monolayer rather than a monolayer of barium on its surface

  2. Cathode power distribution system and method of using the same for power distribution

    Science.gov (United States)

    Williamson, Mark A; Wiedmeyer, Stanley G; Koehl, Eugene R; Bailey, James L; Willit, James L; Barnes, Laurel A; Blaskovitz, Robert J

    2014-11-11

    Embodiments include a cathode power distribution system and/or method of using the same for power distribution. The cathode power distribution system includes a plurality of cathode assemblies. Each cathode assembly of the plurality of cathode assemblies includes a plurality of cathode rods. The system also includes a plurality of bus bars configured to distribute current to each of the plurality of cathode assemblies. The plurality of bus bars include a first bus bar configured to distribute the current to first ends of the plurality of cathode assemblies and a second bus bar configured to distribute the current to second ends of the plurality of cathode assemblies.

  3. Rf Gun with High-Current Density Field Emission Cathode

    International Nuclear Information System (INIS)

    Jay L. Hirshfield

    2005-01-01

    High current-density field emission from an array of carbon nanotubes, with field-emission-transistor control, and with secondary electron channel multiplication in a ceramic facing structure, have been combined in a cold cathode for rf guns and diode guns. Electrodynamic and space-charge flow simulations were conducted to specify the cathode configuration and range of emission current density from the field emission cold cathode. Design of this cathode has been made for installation and testing in an existing S-band 2-1/2 cell rf gun. With emission control and modulation, and with current density in the range of 0.1-1 kA/cm2, this cathode could provide performance and long-life not enjoyed by other currently-available cathodes

  4. Degradation factors of a new long life cathode

    International Nuclear Information System (INIS)

    Zhang Mingchen; Zhang Honglai; Liu Pukun; Li Yutao

    2011-01-01

    This paper analyses the degradation factors of a new long life coated impregnated cathode after accelerated life test. The surface state of the cathode is investigated with scanning electron microscope (SEM) as well as the content and variation of the various elements on the surface and the longitudinal section of the cathode are analyzed with Auger electron spectroscopy (AES) before and after the life test. The analyzing results with SEM show that the cathode coating shrinks at the life end and leads to a rise in its work function. The analyzing results with AES show that the percent of the W increases and the active materials Ba decreases on the cathode surface at the life end. Furthermore, there is less Ba underneath the cathode surface but still a lot of Ba in the tungsten matrix at the life end.

  5. Cathode plasma expansion in diode with explosive emission

    International Nuclear Information System (INIS)

    Zuo Yinghong; Fan Ruyu; Wang Jianguo; Zhu Jinhui

    2012-01-01

    The evolution characteristics of the cathode plasma in a planar diode with explosive emission were analyzed. Be- sides the axial expansion which can reduce the effective anode-cathode gap, the radial expansion of the cathode plasma which can affect the effective emitting area was also taken into account. According to the Child-Langmuir law and the experimental data of current and voltage with a electron vacuum diode under four-pulse mode, the dynamics of the cathode plasma was investigated, on the assumption that the radial speeds of the cathode plasma was approximately equal to the axial speed. The results show that the radial and axial expansion speeds of the cathode plasma are 0.9-2.8 cm/μs. (authors)

  6. Cathodic corrosion: Part 2. Properties of nanoparticles synthesized by cathodic corrosion

    International Nuclear Information System (INIS)

    Yanson, A.I.; Yanson, Yu.I.

    2013-01-01

    We demonstrate how cathodic corrosion in concentrated aqueous solutions enables one to prepare nanoparticles of various metals and metal alloys. Using various characterization methods we show that the composition of nanoparticles remains that of the starting material, and the resulting size distribution remains rather narrow. For the case of platinum we show how the size and possibly even the shape of the nanoparticles can be easily controlled by the parameters of corrosion. Finally, we discuss the advantages of using the nanoparticles prepared by cathodic corrosion for applications in (electro-)catalysis.

  7. Theory of hollow cathode arc discharges. II. Metastable state balance inside the cathode. Application to argon

    International Nuclear Information System (INIS)

    Ferreira, C.M.; Delcroix, J.L.

    1975-01-01

    In the hollow cathode the metastable species are created by fast electrons, which are emitted by the cathode wall and injected in the plasma across a space-charge sheath, and destroyed by Maxwellian electrons. A detailed analysis of the different electronic destruction mechanisms in argon shows that the re-excitation up to 3p 5 4p states plays a very important role. Solutions of the metastable balance equation were obtained in a wide range of variation of the discharge parameters displaying the best conditions of operation to obtain high concentrations [fr

  8. Molten carbonate fuel cell cathode with mixed oxide coating

    Science.gov (United States)

    Hilmi, Abdelkader; Yuh, Chao-Yi

    2013-05-07

    A molten carbonate fuel cell cathode having a cathode body and a coating of a mixed oxygen ion conductor materials. The mixed oxygen ion conductor materials are formed from ceria or doped ceria, such as gadolinium doped ceria or yttrium doped ceria. The coating is deposited on the cathode body using a sol-gel process, which utilizes as precursors organometallic compounds, organic and inorganic salts, hydroxides or alkoxides and which uses as the solvent water, organic solvent or a mixture of same.

  9. Ultra High Energy Density Cathodes with Carbon Nanotubes

    Science.gov (United States)

    2013-12-10

    a) Carbon nanotube paper coated with NCA cathode composite for testing as positive electrode in Li-ion battery (b) Comparison of NCA specific...received and purified CNT electrodes coated with NCA cathode composite. (b) Discharge capacities as a function of rate and cycle for NCA on Al and...thickness increases. The first approach was to cast SOA NCA cathode composites onto CNT current collectors using an adjustable blade coater. The

  10. Knife-edge thin film field emission cathodes

    International Nuclear Information System (INIS)

    Lee, B.; Demroff, H.P.; Drew, M.M.; Elliott, T.S.; Mazumdar, T.K.; McIntyre, P.M.; Pang, Y.; Smith, D.D.; Trost, H.J.

    1993-01-01

    Cathodes made of thin-film field emission arrays (FEA) have the advantages of high current density, pulsed emission, and low bias voltage operation. The authors have developed a technology to fabricate knife-edge field emission cathodes on (110) silicon wafers. The emitter geometry is optimized for efficient modulation at high frequency. Cathode fabrication progress and preliminary analysis of their applications in RF power sources are presented

  11. Structured electron beams from nano-engineered cathodes

    Energy Technology Data Exchange (ETDEWEB)

    Lueangaramwong, A. [NICADD, DeKalb; Mihalcea, D. [NICADD, DeKalb; Andonian, G. [RadiaBeam Tech.; Piot, P. [Fermilab

    2017-03-07

    The ability to engineer cathodes at the nano-scale have open new possibilities such as enhancing quantum eciency via surface-plasmon excitation, forming ultra-low-emittance beams, or producing structured electron beams. In this paper we present numerical investigations of the beam dynamics associated to this class of cathode in the weak- and strong-field regimes.We finally discuss the possible applications of some of the achievable cathode patterns when coupled with other phase space manipulations.

  12. Geiger counters of gamma rays with a bismuth cathode

    International Nuclear Information System (INIS)

    Meunier, R.; Legrand, J.P.

    1953-01-01

    Geiger Muller counters present a lake of efficiency of some per cent, for the γ radiations. In the region 0,3 - 1 MeV, a substantial growth of their output can be obtained by a special construction of their cathode. In accordance with previous works, we constructed some counter of formed cathode by a pleated copper wire fencing covered of Bi by electrolysis. The successive modifications brought to a cylindrical conventional cathode in sheet metal of copper, that succeeds to this type of cathode, drive to an improvement of the output. (M.B.) [fr

  13. Surface Characterization of the LCLS RF Gun Cathode

    International Nuclear Information System (INIS)

    Brachmann, Axel; Decker, Franz-Josef; Ding, Yuantao; Dowell, David; Emma, Paul; Frisch, Josef; Gilevich, Sasha; Hays, Gregory; Hering, Philippe; Huang, Zhirong; Iverson, Richard; Loos, Henrik; Miahnahri, Alan; Nordlund, Dennis; Nuhn, Heinz-Dieter; Pianetta, Piero; Turner, James; Welch, James; White, William; Wu, Juhao; Xiang, Dao

    2012-01-01

    The first copper cathode installed in the LCLS RF gun was used during LCLS commissioning for more than a year. However, after high charge operation (> 500 pC), the cathode showed a decline of quantum efficiency within the area of drive laser illumination. They report results of SEM, XPS and XAS studies that were carried out on this cathode after it was removed from the gun. X-ray absorption and X-ray photoelectron spectroscopy reveal surface contamination by various hydrocarbon compounds. In addition they report on the performance of the second installed cathode with emphasis on the spatial distribution of electron emission.

  14. Cathode fall measurement in a dielectric barrier discharge in helium

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Yanpeng; Zheng, Bin; Liu, Yaoge [School of Electric Power, South China University of Technology, Guangzhou 510640 (China)

    2013-11-15

    A method based on the “zero-length voltage” extrapolation is proposed to measure cathode fall in a dielectric barrier discharge. Starting, stable, and discharge-maintaining voltages were measured to obtain the extrapolation zero-length voltage. Under our experimental conditions, the “zero-length voltage” gave a cathode fall of about 185 V. Based on the known thickness of the cathode fall region, the spatial distribution of the electric field strength in dielectric barrier discharge in atmospheric helium is determined. The strong cathode fall with a maximum field value of approximately 9.25 kV/cm was typical for the glow mode of the discharge.

  15. Explosive-emission cathode fabricated from superconducting cable

    International Nuclear Information System (INIS)

    Vavra, I.; Korenev, S.A.

    1989-01-01

    The authors describe on explosive-emission cathode that is based on stock superconducting cable - type NT-50, for example - that is bunched and held in a copper matrix. The copper matrix is partially etched away to create a multipoint structure for the cathode-plasma initiators. With 100-300 kV on the diode and a distance of 1 cm between the anode and cathode, electron currents of 20-80 and 60-300 A are obtained with cathode diameters of 0.5 and 1 cm, respectively

  16. Reformulation of controlled-release oxycodone and pharmacy dispensing patterns near the US-Canada border.

    Science.gov (United States)

    Gomes, Tara; Paterson, J Michael; Juurlink, David N; Dhalla, Irfan A; Mamdani, Muhammad M

    2012-01-01

    In August 2010, a tamper-resistant formulation of controlled-release oxycodone (OxyContin-OP) was introduced in the United States but not in Canada. Our objective was to determine whether introduction of OxyContin-OP in the United States influenced prescription volumes for the original controlled-release oxycodone formulation (OxyContin) at Canadian pharmacies near the international border. We conducted a population-based, serial, cross-sectional study of prescriptions dispensed from pharmacies in the 3 cities with the highest volume of US-Canada border crossings in Ontario: Niagara Falls, Windsor and Sarnia. We analyzed data on all outpatient prescriptions for OxyContin dispensed by Canadian pharmacies near each border crossing between 2010 Apr. 1 and 2012 Feb. 29. We calculated and compared monthly prescription rates, adjusted per 1000 population and stratified by tablet strength. The number of tablets dispensed near 4 border crossings in the 3 Canadian cities remained stable over the study period. However, the rate of dispensing at pharmacies near the Detroit-Windsor Tunnel increased roughly 4-fold between August 2010 and February 2011, from 505 to 1969 tablets per 1000 population. By April 2011, following warnings to prescribers and pharmacies regarding drug-seeking behaviour, the dispensing rate declined to 1683 tablets per 1000 population in this area. By November 2011, the rate had returned to levels observed in early 2010. Our analyses suggest that 242 075 excess OxyContin tablets were dispensed near the Detroit-Windsor Tunnel between August 2010 and October 2011. Prescribing of the original formulation of controlled-release oxycodone rose substantially near a major international border crossing following the introduction of a tamper-resistant formulation in the United States. It is possible that the restriction of this finding to the area surrounding the Detroit-Windsor Tunnel reflects specific characteristics of this border crossing, including its high

  17. Identification of risks associated with the prescribing and dispensing of oral anticancer medicines in Ireland.

    LENUS (Irish Health Repository)

    Hammond, Lisa

    2012-09-09

    Background Oral anticancer medicines (OAM) facilitate transfer of cancer care into the community, where safeguards developed in hospitals that control their prescribing, dispensing and administration may not exist. Objective To determine if the systems of prescribing and dispensing OAM in Ireland facilitate clinical verification of the prescription, thereby ensuring treatment is tailored and appropriate for the patient. Setting Randomly selected community pharmacies in Ireland and all Irish hospitals with cancer services. Method A questionnaire was sent to a random selection of Irish community pharmacists. A different questionnaire was sent to all Irish hospitals treating cancer patients. One hundred OAM prescriptions were retrospectively reviewed, to assess the information presented and the potential barriers to a community pharmacist performing a clinical verification of the prescription. Main outcome measure Community pharmacist survey: problems experienced when dispensing OAM and risk factors identified with the current system. Hospital pharmacist survey: proportion of hospitals that clinically verify prescriptions for parenteral versus oral anticancer medicines and associated policies. OAM prescription review: proportion of OAM prescriptions that contained sufficient information for a community pharmacist to clinically verify the prescription and safely dispense the medication. Results Sixty-four percent of community pharmacist respondents felt they did not have enough information available to them to safely dispense these prescriptions, and 74 % felt that patients are at risk with the current Irish system of prescribing and dispensing OAM. Irish hospitals do not have systems to ensure that all OAM prescriptions are clinically verified by a pharmacist. Seventeen different agents were prescribed on the prescriptions reviewed. The information provided to the community pharmacist would have allowed them to clinically verify 7 % of the OAM prescriptions

  18. Strategies toward High-Performance Cathode Materials for Lithium-Oxygen Batteries.

    Science.gov (United States)

    Wang, Kai-Xue; Zhu, Qian-Cheng; Chen, Jie-Sheng

    2018-05-11

    Rechargeable aprotic lithium (Li)-O 2 batteries with high theoretical energy densities are regarded as promising next-generation energy storage devices and have attracted considerable interest recently. However, these batteries still suffer from many critical issues, such as low capacity, poor cycle life, and low round-trip efficiency, rendering the practical application of these batteries rather sluggish. Cathode catalysts with high oxygen reduction reaction (ORR) and evolution reaction activities are of particular importance for addressing these issues and consequently promoting the application of Li-O 2 batteries. Thus, the rational design and preparation of the catalysts with high ORR activity, good electronic conductivity, and decent chemical/electrochemical stability are still challenging. In this Review, the strategies are outlined including the rational selection of catalytic species, the introduction of a 3D porous structure, the formation of functional composites, and the heteroatom doping which succeeded in the design of high-performance cathode catalysts for stable Li-O 2 batteries. Perspectives on enhancing the overall electrochemical performance of Li-O 2 batteries based on the optimization of the properties and reliability of each part of the battery are also made. This Review sheds some new light on the design of highly active cathode catalysts and the development of high-performance lithium-O 2 batteries. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Cold cathode electron guns in the LASL high power short-pulse CO2 laser program

    International Nuclear Information System (INIS)

    Singer, S.; Ladish, J.S.; Nutter, M.J.

    1975-01-01

    The Electron Beam Controlled Discharge CO 2 Laser is now firmly established as the only high power short pulse laser amplifier that has been demonstrated to have scaling capabilities to large apertures and energies much greater than 100 J. These devices require a beam of energetic electrons to control the gas discharge that produces the required population inversion. Until recently, the electron source was usually a thermionic emitter, even for rather large lasers, whose heater requirements dwarfed the pulsed energies associated with the transient operation of the laser. With the advent of reliable cold-cathode electron guns, the operation of these lasers has been greatly simplified. At LASL, there are four electron beam controlled laser systems which are in operation, under construction, or in design: the 1 kJ system, now operational; the 2.5 kJ system; the 10 kJ system; and the 100 kJ system. Only the first uses thermionic-emitter electron guns; the remainder use or will use cold cathode sources. The operation of the 200 x 35 cm 2 two sided cold cathode electron gun used in the 2.5 kJ laser system and to be used in the 10 kJ laser is described

  20. Stabilization of a cold cathode electron beam glow discharge for surface treatment

    International Nuclear Information System (INIS)

    Mingolo, N.; Gonzalez, C.R.; Martinez, O.E.; Rocca, J.J.

    1997-01-01

    We have demonstrated that the reproducibility of electron beam pulses generated by a high power, cold cathode glow discharge is greatly improved by adding a small continuous keep-alive discharge current. A current of the order of 200 μA was found to limit the shot to shot current variation to within 1.5%. This stabilization in turn reduces by an order of magnitude the fluctuations of the energy density deposited on the target, demonstrating a reliable energy source for surface treatment. copyright 1997 American Institute of Physics

  1. Stabilization of a cold cathode electron beam glow discharge for surface treatment

    Energy Technology Data Exchange (ETDEWEB)

    Mingolo, N.; Gonzalez, C.R. [Lab. de Haces Dirigidos, Depto. de Fisica, Facultad de Ingenieria, Universidad de Buenos Aires, Paseo Colon 850, 1063 Buenos Aires (Argentina); Martinez, O.E. [Lab. de Electronica Cuantica, Depto. de Fisica, Universidad de Buenos Aires, Pabellon 1, Ciudad Universitaria, 1428 Buenos Aires (Argentina); Rocca, J.J. [Department of Electrical Engineering, Colorado State University, Fort Collins, Colorado 80523 (United States)

    1997-10-01

    We have demonstrated that the reproducibility of electron beam pulses generated by a high power, cold cathode glow discharge is greatly improved by adding a small continuous keep-alive discharge current. A current of the order of 200 {mu}A was found to limit the shot to shot current variation to within 1.5{percent}. This stabilization in turn reduces by an order of magnitude the fluctuations of the energy density deposited on the target, demonstrating a reliable energy source for surface treatment. {copyright} {ital 1997 American Institute of Physics.}

  2. AMSAA Reliability Growth Guide

    National Research Council Canada - National Science Library

    Broemm, William

    2000-01-01

    ... has developed reliability growth methodology for all phases of the process, from planning to tracking to projection. The report presents this methodology and associated reliability growth concepts.

  3. Position resolution of MSGCs with cathode readout

    International Nuclear Information System (INIS)

    Amos, N.; Cremaldi, L.; Finocchiaro, G.; Gobbi, B.; Ng, K.K.; Manzella, V.; Peskov, V.; Rajagopalan, S.; Rubinov, P.; Schamberger, D.; Sellberg, G.; Steffens, J.; Tilden, R.; Wang, P.; Yu, Y.

    1997-01-01

    The performance of a telescope of micro-strip gas chambers (MSGC) has been studied in a beam of pions. Detectors with different anode pitch and with different substrates have been operated using several gas mixtures. The position resolutions obtained by reading out the cathodes for the 200 μm pitch is 42 μm. For the 400 μm pitch detectors the resolution is 42 μm after correcting the centroid positions with a function derived from the data. (orig.)

  4. Coated particles for lithium battery cathodes

    Science.gov (United States)

    Singh, Mohit; Eitouni, Hany Basam; Pratt, Russell Clayton; Mullin, Scott Allen; Wang, Xiao-Liang

    2017-07-18

    Particles of cathodic materials are coated with polymer to prevent direct contact between the particles and the surrounding electrolyte. The polymers are held in place either by a) growing the polymers from initiators covalently bound to the particle, b) attachment of the already-formed polymers by covalently linking to functional groups attached to the particle, or c) electrostatic interactions resulting from incorporation of cationic or anionic groups in the polymer chain. Carbon or ceramic coatings may first be formed on the surfaces of the particles before the particles are coated with polymer. The polymer coating is both electronically and ionically conductive.

  5. Low noise PWC cathode readout system

    International Nuclear Information System (INIS)

    Cisneros, E.; Hutchinson, D.; McShurley, D.; Richter, R.; Shapiro, S.

    1980-10-01

    A system has been developed, primarily to detect the induced charge deposited on PWC cathodes, which is versatile, fast and has a good signal to noise ratio for signals of greater than or equal to 10 -14 Coulomb input. The amplifier system, which is completely separated from the detector by 95 Ω coaxial cables, is followed by a new charge integrating, version of the SHAM/BADC system developed at SLAC. This SHAM IV system is CAMAC based, allowing for computer calibration of the entire system from amplifier through ADC

  6. Cathode Readout with Stripped Resistive Drift Tubes

    International Nuclear Information System (INIS)

    Bychkov, V.N.; Kekelidze, G.D.; Novikov, E.A.; Peshekhonov, V.D.; Shafranov, M.D.; Zhil'tsov, V.E.

    1994-01-01

    A straw tube drift chamber prototype has been constructed and tested. The straw tube material is mylar film covered with carbon layer of resistivity 0.5, 30 and 70 k Ohm/sq. The gas mixture used was Ar/CH 4 . Both the anode wire and cathode signals were detected in order to study the behaviour of the chamber in the presence of X-ray ionization. The construction and the results of the study are presented. 7 refs., 11 figs., 1 tab

  7. Analysis of costs to dispense prescriptions in independently owned, closed-door long-term care pharmacies.

    Science.gov (United States)

    Carroll, Norman V; Rupp, Michael T; Holdford, David A

    2014-03-01

    The need for accurate calculation of long-term care (LTC) pharmacies' costs to dispense (CTD) has become more important as payers have moved toward reimbursement models based on pharmacies' actual acquisition cost for drug products and the Centers for Medicare Medicaid Services (CMS) has implemented requirements that LTC pharmacies must dispense prescriptions for certain branded drugs in 14-day-or-less quantities. To (a) calculate the average cost that the typical independently owned, closed-door LTC pharmacy currently incurs to dispense and deliver a prescription to the resident of a client LTC facility and (b) estimate how CMS-mandated changes to a 14-day-or-less dispensing cycle would affect the typical LTC pharmacy's average CTD. The data requirements and measurement model were developed by academic researchers in consultation with an industry advisory committee of independent LTC pharmacy owners. A survey instrument was constructed to collect financial and operating data required to calculate the CTD. Surveys were distributed via 3 dissemination channels to approximately 1,000 independently owned, closed-door LTC pharmacies. The National Community Pharmacists Association mailed surveys to their LTC members; 3 major national wholesalers distributed surveys to their LTC customers through their newsletters; and 3 LTC group purchasing organizations distributed the surveys to their members through emails, newsletters, mailings, and/or regional meetings. Each pharmacy's CTD was calculated by dividing total LTC dispensing-related 
costs by the total number of prescriptions dispensed. Dispensing-related costs included costs incurred to physically dispense and deliver prescriptions (e.g., dispensing pharmacists' and technicians' salaries and costs of medication containers) and costs incurred to support the dispensing function (e.g., salaries of delivery and medical records personnel). A model based on dispensing-related fixed, variable, and semivariable costs was

  8. Integration of dispenser-printed ultra-low-voltage thermoelectric and energy storage devices

    International Nuclear Information System (INIS)

    Wang, Z; Chen, A; Winslow, R; Madan, D; Nill, M; Wright, P K; Juang, R C; Evans, J W

    2012-01-01

    This paper reports on an integrated energy harvesting prototype that consists of dispenser-printed thermoelectric energy harvesting and electrochemical energy storage devices. Parallel-connected thermoelectric devices with low internal resistances were designed, fabricated and characterized. The use of a commercially available dc-to-dc converter was explored to step-up a 27.1 mV input voltage from a printed thermoelectric device to a regulated 2.34 V output at a maximum of 34% conversion efficiency. The regulated power succeeds in charging dispenser-printed, zinc-based micro-batteries with charging efficiencies of up to 67%. The prototype presented in this work demonstrates the feasibility of deploying a printable, cost-effective and perpetual power solution for practical wireless sensor network applications. (paper)

  9. Microfluidic device and method for focusing, segmenting, and dispensing of a fluid stream

    Science.gov (United States)

    Jacobson, Stephen C [Knoxville, TN; Ramsey, J Michael [Knoxville, TN

    2008-09-09

    A microfluidic device and method for forming and dispensing minute volume segments of a material are described. In accordance with the present invention, a microfluidic device and method are provided for spatially confining the material in a focusing element. The device is also adapted for segmenting the confined material into minute volume segments, and dispensing a volume segment to a waste or collection channel. The device further includes means for driving the respective streams of sample and focusing fluids through respective channels into a chamber, such that the focusing fluid streams spatially confine the sample material. The device may also include additional means for driving a minute volume segment of the spatially confined sample material into a collection channel in fluid communication with the waste reservoir.

  10. Accurate, consistent, and fast droplet splitting and dispensing in electrowetting on dielectric digital microfluidics

    Science.gov (United States)

    Nikapitiya, N. Y. Jagath B.; Nahar, Mun Mun; Moon, Hyejin

    2017-12-01

    This letter reports two novel electrode design considerations to satisfy two very important aspects of EWOD operation—(1) Highly consistent volume of generated droplets and (2) Highly improved accuracy in the generated droplet volume. Considering the design principles investigated two novel designs were proposed; L-junction electrode design to offer high throughput droplet generation and Y-junction electrode design to split a droplet very fast while maintaining equal volume of each part. Devices of novel designs were fabricated and tested, and the results are compared with those of conventional approach. It is demonstrated that inaccuracy and inconsistency of droplet volume dispensed in the device with novel electrode designs are as low as 0.17 and 0.10%, respectively, while those of conventional approach are 25 and 0.76%, respectively. The dispensing frequency is enhanced from 4 to 9 Hz by using the novel design.

  11. Digital Imaging and Piezo-dispenser Actuator in Automatic Flocculation Control

    Directory of Open Access Journals (Sweden)

    Jani TOMPERI

    2012-01-01

    Full Text Available This study presents an image-based on-line control system for a coiled pipe flocculator. A digital imaging technique developed previously is utilized to measure the characteristic floc size and a high-pressure piezo-dispenser is introduced for accurate dosing and rapid mixing of the flocculant. The controller is a conventional PI controller. Step change experiments on feed water quality, flow rate and desired floc size have been carried out for controller tuning and testing. The paper shows that the piezo-dispenser provides better flocculation results than a conventional dosing pump, and the flocculation result can be automatically controlled even when the feed water quality rapidly changes. The proposed flocculator is a simple, inexpensive and practical system for long-term laboratory tests to investigate the functionality of flocculants on varying feed waters.

  12. A reliability simulation language for reliability analysis

    International Nuclear Information System (INIS)

    Deans, N.D.; Miller, A.J.; Mann, D.P.

    1986-01-01

    The results of work being undertaken to develop a Reliability Description Language (RDL) which will enable reliability analysts to describe complex reliability problems in a simple, clear and unambiguous way are described. Component and system features can be stated in a formal manner and subsequently used, along with control statements to form a structured program. The program can be compiled and executed on a general-purpose computer or special-purpose simulator. (DG)

  13. Validating a proxy for disease progression in metastatic cancer patients using prescribing and dispensing data.

    Science.gov (United States)

    Joshi, Vikram; Adelstein, Barbara-Ann; Schaffer, Andrea; Srasuebkul, Preeyaporn; Dobbins, Timothy; Pearson, Sallie-Anne

    2017-10-01

    Routine data collections are used increasingly to examine outcomes of real-world cancer drug use. These datasets lack clinical details about important endpoints such as disease progression. To validate a proxy for disease progression in metastatic cancer patients using prescribing and dispensing claims. We used data from a cohort study of patients undergoing chemotherapy who provided informed consent to the collection of cancer-treatment data from medical records and linkage to pharmaceutical claims. We derived proxy decision rules based on changes to drug treatment in prescription histories (n = 36 patients) and validated the proxy in prescribing data (n = 62 patients). We adapted the decision rules and validated the proxy in dispensing data (n = 109). Our gold standard was disease progression ascertained in patient medical records. Individual progression episodes were the unit of analysis for sensitivity and Positive Predictive Value (PPV) calculations and specificity and Negative Predictive Value (NPV) were calculated at the patient level. The sensitivity of our proxy in prescribing data was 74.3% (95% Confidence Interval (CI), 55.6-86.6%) and PPV 61.2% (95% CI, 45.0-75.3%); specificity and NPV were 87.8% (95% CI, 73.8-95.9%) and 100% (95% CI, 90.3-100%), respectively. In dispensing data, the sensitivity of our proxy was 64% (95% CI, 55.0-77.0%) and PPV 56.0% (95% CI, 43.0-69.0%); specificity and NPV were 81% (95% CI, 70.05-89.0%) and 91.0% (95% CI, 82.0-97.0%), respectively. Our proxy overestimated episodes of disease progression. The proxy's performance is likely to improve if the date of prescribing is used instead of date of dispensing in claims data and by incorporating medical service claims (such as imaging prior to drug changes) in the algorithm. Our proxy is not sufficiently robust for use in real world comparative effectiveness research for cancer medicines. © 2016 John Wiley & Sons Australia, Ltd.

  14. Care relationships at stake? Home healthcare professionals’ experiences with digital medicine dispensers – a qualitative study

    OpenAIRE

    Nakrem, Sigrid; Solbjør, Marit; Pettersen, Ida Nilstad; Kleiven, Hanne Hestvik

    2018-01-01

    Background Although digital technologies can mitigate the burdens of home healthcare services caused by an ageing population that lives at home longer with complex health problems, research on the impacts and consequences of digitalised remote communication between patients and caregivers is lacking. The present study explores how home healthcare professionals had experienced the introduction of digital medicine dispensers and their influence on patient-caregiver relationships. Methods...

  15. Subsidising patient dispensing fees: the cost of injecting equity into the opioid pharmacotherapy maintenance system.

    Science.gov (United States)

    Chalmers, Jenny; Ritter, Alison

    2012-11-01

    Australian pharmacotherapy maintenance programs incur costs to patients. These dispensing fees represent a financial burden to patients and are inconsistent with Australian health-care principles. No previous work has examined the current costs nor the future predicted costs if government subsidised dispensing fees. A system dynamics model, which simulated the flow of patients into and out of methadone maintenance treatment, was developed. Costs were imputed from existing research data. The approach enabled simulation of possible behavioural responses to a fee subsidy (such as higher retention) and new estimates of costs were derived under such scenarios. Current modelled costs (AUS$11.73m per month) were largely borne by state/territory government (43%), with patients bearing one-third (33%) of the total costs and the Commonwealth one-quarter (24%). Assuming no behavioural changes associated with fee subsidies, the cost of subsidising the dispensing fees of Australian methadone patients would be $3.9m per month. If retention were improved as a result of fee subsidy, treatment numbers would increase and the model estimates an additional cost of $0.8m per month. If this was coupled with greater numbers entering treatment, the costs would increase by a further $0.4m per month. In total, full fee subsidy with modelled behavioural changes would increase per annum government expenditure by $81.8m to $175.8m. If government provided dispensing fee relief for methadone maintenance patients, it would be a costly exercise. However, these additional costs are offset by the social and health gains achieved from the methadone maintenance program. © 2012 Australasian Professional Society on Alcohol and other Drugs.

  16. ASHP national survey of pharmacy practice in hospital settings: dispensing and administration--2011.

    Science.gov (United States)

    Pedersen, Craig A; Schneider, Philip J; Scheckelhoff, Douglas J

    2012-05-01

    Results of the 2011 ASHP national survey of pharmacy practice in hospital settings that pertain to dispensing and administration are presented. A stratified random sample of pharmacy directors at 1401 general and children's medical-surgical hospitals in the United States were surveyed by mail. In this national probability sample survey, the response rate was 40.1%. Decentralization of the medication-use system continues, with 40% of hospitals using a decentralized system and 58% of hospitals planning to use a decentralized model in the future. Automated dispensing cabinets were used by 89% of hospitals, robots were used by 11%, carousels were used in 18%, and machine-readable coding was used in 34% of hospitals to verify doses before dispensing. Overall, 65% of hospitals had a United States Pharmacopeia chapter 797 compliant cleanroom for compounding sterile preparations. Medication administration records (MARs) have become increasingly computerized, with 67% of hospitals using electronic MARs. Bar-code-assisted medication administration was used in 50% of hospitals, and 68% of hospitals had smart infusion pumps. Health information is becoming more electronic, with 67% of hospitals having partially or completely implemented an electronic health record and 34% of hospitals having computerized prescriber order entry. The use of these technologies has substantially increased over the past year. The average number of full-time equivalent staff per 100 occupied beds averaged 17.5 for pharmacists and 15.0 for technicians. Directors of pharmacy reported declining vacancy rates for pharmacists. Pharmacists continue to improve medication use at the dispensing and administration steps of the medication-use system. The adoption of new technology is changing the philosophy of medication distribution, and health information is rapidly becoming electronic.

  17. Concern about the Expanding Prescription Drug Epidemic: A Survey of Licensed Prescribers and Dispensers.

    Science.gov (United States)

    Wright, R Eric; Reed, Nia; Carnes, Neal; Kooreman, Harold E

    2016-01-01

    Prescription drug misuse and abuse has reached epidemic levels in the U.S., and stands as a leading cause of death. As the primary gatekeepers to the medications contributing to this epidemic, it is critical to understand the views of licensed health care professionals. In this study, we examine health care professionals' concern regarding prescription drug abuse in their communities and the impact their concern has had on their prescribing and dispensing practices. An online survey of licensed health care providers. Conducted in Indiana. This study was a state-wide evaluation of Indiana's prescription drug monitoring program. The questionnaire asked respondents how concerned they were about prescription drug abuse in their community. Variation in the level of concern was examined using ordinary least squares regression and information about the respondents' demographic background and clinical experience. In addition, we used logistic regression to examine whether concern was associated with changing prescribing and/or dispensing behavior. The majority of providers indicated they were "moderately" or "extremely concerned" about prescription drug abuse in their communities. The level of concern, however, varied significantly by profession, with pharmacists, physicians, nurse practitioners/physician assistants being more concerned than dentists. Additional analyses indicate that providers with higher levels of concern were those who also reported recently changing their prescribing and/or dispensing behavior. The voluntary nature and geographical focus of the study limits the generalizability of the findings. Concern about prescription drug abuse is generally high across the major health care professions; however, a significant minority of providers, particularly among dentists, expressed little or no concern about the epidemic. Increasing health care providers' general level of concern about prescription drug abuse may be an effective public health tool for

  18. Use of simulated patients to evaluate combined oral contraceptive dispensing practices of community pharmacists.

    Directory of Open Access Journals (Sweden)

    Paulo Roque Obreli-Neto

    Full Text Available BACKGROUND: Combined oral contraceptive (COC use is the most commonly used reversible method of birth control. The incorrect use of COCs is frequent and one of the most common causes of unintended pregnancies. Community pharmacists (CPs are in a strategic position to improve COC use because they are the last health professional to interact with patients before drug use. OBJECTIVE: To evaluate the COC dispensing practices of CPs in a developing country. METHOD: A cross-sectional study was conducted in community pharmacies of Assis and Ourinhos microregions, Brazil, between June 1, 2012, and October 30, 2012. Four simulated patients (SPs (with counseled audio recording visited community pharmacies with a prescription for Ciclo 21(® (a COC containing ethinyl estradiol 30 mcg + levonorgestrel 15 mcg. The audio recording of every SP visit was listened to independently by 3 researchers to evaluate the COC dispensing practice. The percentage of CPs who performed a screening for safe use of COCs (i.e., taking of patients' medical and family history, and measuring of blood pressure and provided counseling, as well as the quality of the screening and counseling, were evaluated. RESULTS: Of the 185 CPs contacted, 41 (22.2% agreed to participate in the study and finished the study protocol. Only 3 CPs asked the SP a question (1 question asked by each professional, and all of the questions were closed-ended, viz., "do you smoke?" (n = 2 and "what is your age?" (n = 1. None of the CPs measured the patient's blood pressure. Six CPs provided counseling when dispensing COCs (drug dosing, 5 CPs; possible adverse effects, 2 CPs, and one CP provided counseling regarding both aspects. CONCLUSION: The CPs evaluated did not dispense COC appropriately and could influence in the occurrence of negatives therapeutic outcomes such as adverse effects and treatment failure.

  19. Space-time-dependent development of the plasma in a pulsed hollow-cathode discharge

    International Nuclear Information System (INIS)

    Schaefer, G.; Wages, M.

    1988-01-01

    This paper presents streak camera investigations on the space-time-dependent development of pulsed hollow-cathode discharges (HCD's) starting from low-current preionization discharges. The discharges started closer to the end of the cathode, then moved further into the cathode, and then spread over a longer range along the axis of the cathode. The depth range of the intense pulsed hollow-cathode plasma was found to be two to eight times the cathode diameter

  20. Numerical Simulation Analysis of High-precision Dispensing Needles for Solid-liquid Two-phase Grinding

    Science.gov (United States)

    Li, Junye; Hu, Jinglei; Wang, Binyu; Sheng, Liang; Zhang, Xinming

    2018-03-01

    In order to investigate the effect of abrasive flow polishing surface variable diameter pipe parts, with high precision dispensing needles as the research object, the numerical simulation of the process of polishing high precision dispensing needle was carried out. Analysis of different volume fraction conditions, the distribution of the dynamic pressure and the turbulence viscosity of the abrasive flow field in the high precision dispensing needle, through comparative analysis, the effectiveness of the abrasive grain polishing high precision dispensing needle was studied, controlling the volume fraction of silicon carbide can change the viscosity characteristics of the abrasive flow during the polishing process, so that the polishing quality of the abrasive grains can be controlled.

  1. Raw Milk Hygiene at Local Markets and Automatic Milk Dispenser Machines

    Directory of Open Access Journals (Sweden)

    Gheorghe Şteţca

    2014-11-01

    Full Text Available In Romania, direct sales of raw milk to the final consumer is developed based on the local regulations. These are in accordance to European Regulation that must meet some quality requirements for the total number of germs, somatic cells, without antibiotics, coming from healthy animals who did not suffer from diseases that can be transmitted to humans through milk. Raw milk is sold in Romania in local markets and by automatic milk dispenser machines. Based on these regulations, a study regarding the quality and security to human health of raw milk was conducted on the commercialized milk in local markets and automatic milk dispensers. During May-June 2014 samples of raw milk were collected from Cluj-Napoca local markets and automatic milk dispensers. All samples were kept to refrigeration conditions until the moment of analyze which took place at the sampling day. The following parameters were taken into account: fat content, protein, casein, lactose, nonfat dry matter, pH, milk freezing point, added water, antibiotics residues, milk urea, number of germ cells and somatic cells. All obtained results were verified by the validated methods applied. Our research can be forward conducted in order to verify the hygiene and composition of milk from the whole dairy chain. 

  2. Use of direct washing of chemical dispense nozzle for defect control

    Science.gov (United States)

    Linnane, Michael; Mack, George; Longstaff, Christopher; Winter, Thomas

    2006-03-01

    Demands for continued defect reduction in 300mm IC manufacturing are driving process engineers to examine all aspects of the chemical apply process for improvement. Historically, the defect contribution from photoresist apply nozzles has been minimized through a carefully controlled process of "dummy dispenses" to keep the photoresist in the tip "fresh" and remove any solidified material, a preventive maintenance regime involving periodic cleaning or replacing of the nozzles, and reliance on a pool of solvent within the nozzle storage block to keep the photoresist from solidifying at the nozzle tip. The industry standard has worked well for the most part but has limitations in terms of cost effectiveness and absolute defect elimination. In this study, we investigate the direct washing of the chemical apply nozzle to reduce defects seen on the coated wafer. Data is presented on how the direct washing of the chemical dispense nozzle can be used to reduce coating related defects, reduce material costs from the reduction of "dummy dispense", and can reduce equipment downtime related to nozzle cleaning or replacement.

  3. Measurement of microbic contamination rate in the dispensing process making suspension of barium sulfate powder

    International Nuclear Information System (INIS)

    Kim, Young Keun; Lee, Yang Sub; Cho, Cheong Chan; Ryu, Meung Sun; Lee, Kyung Sup

    2001-01-01

    The purpose of this study is to investigate the contamination rate of barium sulfate suspension made in the exposed state in usual circumstances. This study was performed in four university hospital using the contrast media by barium sulfate powder. The specimen were detected at dispensing water, agitator and mixing tank. We also classified the suspension into general bacteria, mycete and Bacillus coli infection. The tap water were used to dispense water in the all hospitals. Bacillus coli were not detected in the all. General bacteria and mycete were not detected in the one specimen, but detected in two specimen over defined value. In the contamination rate of agitator, mixing tank, and the manufactured. Bacillus coli were not detected in all. However, general bacteria and mycete were detected too numberous to count. In conclusion, the refined water must be used in dispensing water in manufacturing suspension. The disinfectant is also used in washing the agitator and mixing tank for sterilization. Hand washing is indispensable to manufacturing suspension for preventing from infection

  4. Immediate or deferred adjustment of drug regimens in multidose drug dispensing systems.

    Science.gov (United States)

    Mertens, Bram J; Kwint, Henk-Frans; van Marum, Rob J; Bouvy, Marcel L

    2018-05-18

    Multidose drug dispensing (MDD) is used to help patients take their medicines appropriately. Little is known about drug regimen changes within these MDD systems and how they are effectuated by the community pharmacist. Manual immediate adjustments of the MDD system could introduce dispensing errors. MDD guidelines therefore recommend to effectuate drug regimen changes at the start of a new MDD system. The aim of this study was to investigate the frequency, type, procedure followed, immediate necessity, and time taken to make MDD adjustments. This was a cross-sectional study in eight community pharmacies in the Netherlands. All adjustments to MDD systems were systematically documented for 3 weeks by the community pharmacist. Overall, 261 MDD adjustments involving 364 drug changes were documented for 250 patients: 127 (35%) drug changes involved the addition of a new drug, 124 (34%) a change in dosage, and 95 (26%) drug discontinuation. Of the MDD adjustments, 135 (52%) were effectuated immediately: 81 (31%) by adjusting the MDD system manually, 49 (19%) by temporarily dispensing the drug separately from the MDD system, and 5 (2%) by ordering a new MDD system. Pharmacists considered that 36 (27%) of the immediate MDD adjustments could have been deferred until the next MDD system was produced. Immediate adjustment took significantly longer than deferred adjustment (p < 0.001). This study shows that in patients using MDD systems, over half of the drug regimen changes are adjusted immediately. The necessity of these immediate changes should be critically evaluated. Copyright © 2018. Published by Elsevier Inc.

  5. [Impact of an automated dispensing system for medical devices in cardiac surgery department].

    Science.gov (United States)

    Clou, E; Dompnier, M; Kably, B; Leplay, C; Poupon, E; Archer, V; Paul, M

    2018-01-01

    To secure medical devices' management, the implementation of automated dispensing system in surgical service has been realized. The objective of this study was to evaluate security, organizational and economic impact of installing automated dispensing system for medical devices (ASDM). The implementation took place in a cardiac surgery department. Security impact was assessed by comparing traceability rate of implantable medical devices one year before and one year after installation. Questionnaire on nurses' perception and satisfaction completed this survey. Resupplying costs, stocks' evolution and investments for the implementation of ASDM were the subject of cost-benefit study. After one year, traceability rate is excellent (100%). Nursing staffs were satisfied with 87.5% by this new system. The introduction of ASDM allowed a qualitative and quantitative decrease in stocks, with a reduction of 30% for purchased medical devices and 15% for implantable medical devices in deposit-consignment. Cost-benefit analysis shows a rapid return on investment. Real stock decrease (purchased medical devices) is equivalent to 46.6% of investment. Implementation of ASDM allows to secure storage and dispensing of medical devices. This system has also an important economic impact and appreciated by users. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  6. Compact open cathode feed system for PEMFCs

    International Nuclear Information System (INIS)

    Ling, C.Y.; Cao, H.; Chen, Y.; Han, M.; Birgersson, E.

    2016-01-01

    Highlights: • Two different modes of feeding air into an open cathode PEMFC stack were studied. • Drawing air, as opposed to blowing air, into the stack results in more uniform air velocities entering the stack. • The uniform inlet velocities help maintain a more even temperature distribution field. • A 16% increase in power output is observed by drawing air into the stack. - Abstract: The open cathode design is commonly adopted for small sized proton exchange membrane fuel cells (PEMFCs) as it allows for smaller footprint and thus, higher power density. Axial fans are typically used to supply oxygen in these PEMFC systems. Apart from controlling stoichiometry, they also play a critical role in regulating internal temperature. This suggests that its location could have significant impact on fuel cell performance. In this work, the location of the fan is varied from the front to the rear in order to blow air or draw air into the stack respectively. The latter configuration reduces the non-uniformity in temperature and velocity by around 2 and 4 times respectively, resulting in a 16% increase in overall stack performance.

  7. Influence of substrate topography on cathodic delamination of anticorrosive coatings

    DEFF Research Database (Denmark)

    Sørensen, Per Aggerholm; Kiil, Søren; Dam-Johansen, Kim

    2009-01-01

    and thereby the substrate topography, whereas the coating thickness had little influence. The presence of a significant potential gradient between the anode and the cathode and the dependency of the delamination rate on the tortuosity of the steel surface suggests that cathodic delamination is controlled...

  8. The Effect of Substrate Topography on Coating Cathodic Delamination

    DEFF Research Database (Denmark)

    Erik Weinell, Claus; Sørensen, Per A.; Kiil, Søren

    2011-01-01

    This article describes the effect of steel substrate topography on coating cathodic delamination. The study showed that the surface preparation can be used to control and minimize the rate of cathodic delamination. The coating should have maximum wetting properties so that substrates with high...

  9. Wire winding increases lifetime of oxide coated cathodes

    Science.gov (United States)

    Kerslake, W.; Vargo, D.

    1965-01-01

    Refractory-metal heater base wound with a thin refractory metal wire increases the longevity of oxide-coated cathodes. The wire-wound unit is impregnated with the required thickness of metal oxide. This cathode is useful in magnetohydrodynamic systems and in electron tubes.

  10. Cathodic disbonding of organic coatings on submerged steel

    Energy Technology Data Exchange (ETDEWEB)

    Knudsen, Ole oeystein

    1998-12-31

    In offshore oil production, submerged steel structures are commonly protected by an organic coating in combination with cathodic protection. The main advantage is that the coating decreases the current demand for cathodic protection. But the coating degrades with time. This thesis studies one of the most important mechanisms for coating degradation in seawater, cathodic disbonding. Seven commercial coatings and two model coatings with various pigmentations have been studied. Parameter studies, microscopy and studies of free films were used in the mechanism investigations. Exposure to simulated North Sea conditions was used in the performance studies. The effect of aluminium and glass barrier pigments on cathodic disbonding was investigated. The mechanism for the effect of the aluminium pigments on cathodic disbonding was also investigated. The transport of charge and oxygen to the steel/coating interface during cathodic disbonding was studied for two epoxy coatings. Cathodic disbonding, blistering and current demand for cathodic protection was measured for nine commercial coatings for submerged steel structures, using the ASTM-G8 standard test and a long term test under simulated North Sea conditions. The relevance of the ASTM-G8 test as a prequalification test was evaluated. 171 refs., 40 figs., 6 tabs.

  11. Reducing DRIFT backgrounds with a submicron aluminized-mylar cathode

    Science.gov (United States)

    Battat, J. B. R.; Daw, E.; Dorofeev, A.; Ezeribe, A. C.; Fox, J. R.; Gauvreau, J.-L.; Gold, M.; Harmon, L.; Harton, J.; Lafler, R.; Landers, J.; Lauer, R. J.; Lee, E. R.; Loomba, D.; Lumnah, A.; Matthews, J.; Miller, E. H.; Mouton, F.; Murphy, A. St. J.; Paling, S. M.; Phan, N.; Sadler, S. W.; Scarff, A.; Schuckman, F. G.; Snowden-Ifft, D.; Spooner, N. J. C.; Walker, D.

    2015-09-01

    Background events in the DRIFT-IId dark matter detector, mimicking potential WIMP signals, are predominantly caused by alpha decays on the central cathode in which the alpha particle is completely or partially absorbed by the cathode material. We installed a 0.9 μm thick aluminized-mylar cathode as a way to reduce the probability of producing these backgrounds. We study three generations of cathode (wire, thin-film, and radiologically clean thin-film) with a focus on the ratio of background events to alpha decays. Two independent methods of measuring the absolute alpha decay rate are used to ensure an accurate result, and agree to within 10%. Using alpha range spectroscopy, we measure the radiologically cleanest cathode version to have a contamination of 3.3±0.1 ppt 234U and 73±2 ppb 238U. This cathode reduces the probability of producing an RPR from an alpha decay by a factor of 70±20 compared to the original stainless steel wire cathode. First results are presented from a texturized version of the cathode, intended to be even more transparent to alpha particles. These efforts, along with other background reduction measures, have resulted in a drop in the observed background rate from 500/day to 1/day. With the recent implementation of full-volume fiducialization, these remaining background events are identified, allowing for background-free operation.

  12. Cathodic protection -- Addition of 6 anodes to existing rectifier 31

    International Nuclear Information System (INIS)

    Lane, W.M.

    1995-01-01

    This Acceptance Test Procedure (ATP) has been prepared to demonstrate that the cathodic protection system additions are installed, connected, and function as required by project criteria. The cathodic protection system is for the tank farms on the Hanford Reservation. The tank farms store radioactive wastes

  13. Development of cathode material for lithium-ion batteries

    Directory of Open Access Journals (Sweden)

    Rustam Mukhtaruly Turganaly

    2014-08-01

    Full Text Available The electrochemical characteristics of the cathode material coated with carbon layer has been developed. Various carbon coating methods. There  has been carried out a comparative electrochemical analysis of the coated and uncoated with carbon cathode material. 

  14. Plasma-induced field emission study of carbon nanotube cathode

    Directory of Open Access Journals (Sweden)

    Yi Shen

    2011-10-01

    Full Text Available An investigation on the plasma-induced field emission (PFE properties of a large area carbon nanotube (CNT cathode on a 2 MeV linear induction accelerator injector is presented. Experimental results show that the cathode is able to emit intense electron beams. Intense electron beams of 14.9–127.8  A/cm^{2} are obtained from the cathode. The CNT cathode desorbs gases from the CNTs during the PFE process. The fast cathode plasma expansion affects the diode perveance. The amount of outgassing is estimated to be 0.06–0.49  Pa·L, and the ratio of outgassing and electron are roughly calculated to be within the range of 170–350 atoms per electron. The effect of the outgassing is analyzed, and the outgassing mass spectrum of the CNT cathode has been studied during the PFE. There is a significant desorption of CO_{2}, N_{2}(CO, and H_{2} gases, which plays an important role during the PFE process. All the experiments demonstrate that the outgassing plays an important role in the formation of the cathode plasma. Moreover, the characteristic turn-on time of the CNT cathode was measured to be 39 ns.

  15. Cathode refunctionalization as a lithium ion battery recycling alternative

    Science.gov (United States)

    Ganter, Matthew J.; Landi, Brian J.; Babbitt, Callie W.; Anctil, Annick; Gaustad, Gabrielle

    2014-06-01

    An approach to battery end-of-life (EOL) management is developed involving cathode refunctionalization, which enables remanufacturing of the cathode from EOL materials to regain the electrochemical performance. To date, the optimal end-of-life management of cathode materials is based on economic value and environmental impact which can influence the methods and stage of recycling. Traditional recycling methods can recover high value metal elements (e.g. Li, Co, Ni), but still require synthesis of new cathode from a mix of virgin and recovered materials. Lithium iron phosphate (LiFePO4) has been selected for study as a representative cathode material due to recent mass adoption and limited economic recycling drivers due to the low inherent cost of iron. Refunctionalization of EOL LiFePO4 cathode was demonstrated through electrochemical and chemical lithiation methods where the re-lithiated LiFePO4 regained the original capacity of 150-155 mAh g-1. The environmental impact of the new recycling technique was determined by comparing the embodied energy of cathode material originating from virgin, recycled, and refunctionalized materials. The results demonstrate that the LiFePO4 refunctionalization process, through chemical lithiation, decreases the embodied energy by 50% compared to cathode production from virgin materials.

  16. Dynamic Aspects of Solid Solution Cathodes for Electrochemical Power Sources

    DEFF Research Database (Denmark)

    Atlung, Sven; West, Keld; Jacobsen, Torben

    1979-01-01

    Battery systems based on alkali metal anodes and solid solution cathodes,i.e., cathodes based on the insertion of the alkali cation in a "host lattice,"show considerable promise for high energy density storage batteries. Thispaper discusses the interaction between battery requirements...

  17. A Preliminary Study on Cathodic Prevention in Reinforced Mortar

    NARCIS (Netherlands)

    Koleva, D.A.; Van Breugel, K.; Mol, J.M.C.; De Wit, J.H.W.

    2010-01-01

    This work presents the preliminary tests on the performance of cathodic prevention (CPre) in reinforced mortar, subjected to aggressive (10% NaCl environment). Cathodic prevention is an electrochemical technique for minimizing, actually "preventing" any eventual corrosion of the steel bars in

  18. Implementing a bar-code assisted medication administration system: effects on the dispensing process and user perceptions.

    Science.gov (United States)

    Samaranayake, N R; Cheung, S T D; Cheng, K; Lai, K; Chui, W C M; Cheung, B M Y

    2014-06-01

    We assessed the effects of a bar-code assisted medication administration system used without the support of computerised prescribing (stand-alone BCMA), on the dispensing process and its users. The stand-alone BCMA system was implemented in one ward of a teaching hospital. The number of dispensing steps, dispensing time and potential dispensing errors (PDEs) were directly observed one month before and eight months after the intervention. Attitudes of pharmacy and nursing staff were assessed using a questionnaire (Likert scale) and interviews. Among 1291 and 471 drug items observed before and after the introduction of the technology respectively, the number of dispensing steps increased from five to eight and time (standard deviation) to dispense one drug item by one staff personnel increased from 0.8 (0.09) to 1.5 (0.12) min. Among 2828 and 471 drug items observed before and after the intervention respectively, the number of PDEs increased significantly (Psystem offered less benefit to the dispensing process (9/16). Nursing staff perceived the system as useful in improving the accuracy of drug administration (7/10). Implementing a stand-alone BCMA system may slow down and complicate the dispensing process. Nursing staff believe the stand-alone BCMA system could improve the drug administration process but pharmacy staff believes the technology would be more helpful if supported by computerised prescribing. However, periodical assessments are needed to identify weaknesses in the process after implementation, and all users should be educated on the benefits of using this technology. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Analytical study of electron flows with a virtual cathode

    International Nuclear Information System (INIS)

    Dubinov, A.E.

    2000-01-01

    The dynamics of the electron flow behavior by its injection into a half-space is considered. Two problems are considered, namely the long-term injection of a monoenergetic electron flow and instantaneous flow injection with an assigned electron energy spectrum. The all flow electrons in both cases return to the injection plane. The simple analytical self-consistent model of the initial stage of the virtual cathode formation in a plane-parallel equipotential gap is plotted in the course of analysis whereof the duration of the virtual cathode formation process is determined. The performance of this model is not limited by the multivalence of the electron velocity in the flow. This makes it possible to extend the frames of the model performance relative to the moment of the virtual cathode formation and to consider its dynamics. The frequency of electron oscillations in the potential cathode-virtual cathode well is determined on the basis of the above model [ru

  20. New doped tungsten cathodes. Applications to power grid tubes

    International Nuclear Information System (INIS)

    Cachard, J. de; Cadoret, K; Martinez, L.; Veillet, D.; Millot, F.

    2001-01-01

    Thermionic emission behavior of tungsten/tungsten carbide modified with rare earth (La, Ce, Y) oxides is examined on account of suitability to deliver important current densities in a thermo-emissive set up and for long lifetime. Work functions of potential cathodes have been determined from Richardson plots for La 2 O 3 doped tungsten and for tungsten covered with variable compositions rare earth tungstates. The role of platinum layers covering the cathode was also examined. Given all cathodes containing mainly lanthanum oxides were good emitters, emphasis was put on service lifetime. Comparisons of lifetime in tungsten doped with rare earth oxides and with rare earth tungstates show that microstructure of the operating cathodes may play the major role in the research of very long lifetime cathodes. Based on these results, tests still running show lifetime compatible with power grid tubes applications. (author)

  1. Focused cathode design to reduce anode heating during vircator operation

    Energy Technology Data Exchange (ETDEWEB)

    Lynn, Curtis F.; Dickens, James C.; Neuber, Andreas A. [Center for Pulsed Power and Power Electronics, Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas 79409 (United States)

    2013-10-15

    Virtual cathode oscillators, or vircators, are a type of high power microwave device which operates based on the instability of a virtual cathode, or cloud of electrons, which forms when electron current injected into the drift tube exceeds the space charge limited current within the drift tube. Anode heating by the electron beam during vircator operation ultimately limits achievable pulse lengths, repetition rates, and the duration of burst mode operation. This article discusses a novel cathode design that focuses electrons through holes in the anode, thus significantly reducing anode heating by the electrons emitted from the cathode during the first transit through the A-K gap. Reflexing electrons continue to deposit energy on the anode; however, the discussed minimization of anode heating by main beam electrons has the potential to enable higher repetition rates as well as efficiency and longer diode lifetime. A simulation study of this type of cathode design illustrates possible advantages.

  2. The role of pharmacists and emergency contraception: Are pharmacists' perceptions of emergency contraception predictive of their dispensing practices?

    Science.gov (United States)

    Richman, Alice R; Daley, Ellen M; Baldwin, Julie; Kromrey, Jeff; O'Rourke, Kathleen; Perrin, Kay

    2012-10-01

    Pharmacists can play a critical role in the access to emergency contraception (EC). We assessed if knowledge and attitudes were predictive of EC dispensing among a statewide sample of Florida pharmacists, who have legal authority to refuse to dispense medications. In 2008, surveys were mailed to a random sample of 1264 pharmacists registered with the Florida Board of Pharmacy. Data from 272 pharmacists (22% response rate) were analyzed using bivariate and multivariate logistic regression. Fifty-six percent of respondents incorrectly answered that EC causes birth defects, and 46% replied that it causes abortion. Only 22% said that EC can be purchased in advance of need. Many felt uncomfortable dispensing to adolescents (61%) and men (58%). Knowledge about EC was the most important predictor of dispensing [odds ratio (OR)=1.57, 95% confidence interval (CI) 1.22-2.03]. In particular, pharmacists who reported that EC does not act as an abortifacient were more likely to dispense it (OR=4.64, 95% CI 2.15-10.00). Correct information about EC was the most important predictor of pharmacists' dispensing EC. To expand availability of EC, pharmacists will have to become better informed. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Increasing Access to Subsidized Artemisinin-based Combination Therapy through Accredited Drug Dispensing Outlets in Tanzania

    Directory of Open Access Journals (Sweden)

    Gabra Michael

    2011-06-01

    Full Text Available Abstract Background In Tanzania, many people seek malaria treatment from retail drug sellers. The National Malaria Control Program identified the accredited drug dispensing outlet (ADDO program as a private sector mechanism to supplement the distribution of subsidized artemisinin-based combination therapies (ACTs from public facilities and increase access to the first-line antimalarial in rural and underserved areas. The ADDO program strengthens private sector pharmaceutical services by improving regulatory and supervisory support, dispenser training, and record keeping practices. Methods The government's pilot program made subsidized ACTs available through ADDOs in 10 districts in the Morogoro and Ruvuma regions, covering about 2.9 million people. The program established a supply of subsidized ACTs, created a price system with a cost recovery plan, developed a plan to distribute the subsidized products to the ADDOs, trained dispensers, and strengthened the adverse drug reactions reporting system. As part of the evaluation, 448 ADDO dispensers brought their records to central locations for analysis, representing nearly 70% of ADDOs operating in the two regions. ADDO drug register data were available from July 2007-June 2008 for Morogoro and from July 2007-September 2008 for Ruvuma. This intervention was implemented from 2007-2008. Results During the pilot, over 300,000 people received treatment for malaria at the 448 ADDOs. The percentage of ADDOs that dispensed at least one course of ACT rose from 26.2% during July-September 2007 to 72.6% during April-June 2008. The number of malaria patients treated with ACTs gradually increased after the start of the pilot, while the use of non-ACT antimalarials declined; ACTs went from 3% of all antimalarials sold in July 2007 to 26% in June 2008. District-specific data showed substantial variation among the districts in ACT uptake through ADDOs, ranging from ACTs representing 10% of all antimalarial sales

  4. The effect of cathode surface impurities on gap closure

    International Nuclear Information System (INIS)

    Hinshelwood, D.D.

    1983-01-01

    Gap closure due to cathode (or anode) plasma motion is often the principal limitation on the pulse length of intense beam diodes and magnetically insulated transmission lines. Since the plasma expansion velocity is typically on the order of the sound speed, a high atomic number plasma is desirable. In recent experiments performed on a Sandia Nereus accelerator (240kV, 50kA, 3-30kA/cm 2 , 70ns) with a parallel plate diode, the cathode plasma was seen to be composed of both the cathode substrate material and constituents (hydrogen and carbon) of surface contaminants such as pump oils. The plasma expansion velocities, inferred from impedance measurements, were 1.5-2 cm/μs and were the same for carbon, aluminum and stainless steel cathodes. This similarity, combined with the temperature estimates of 2-3eV obtained from spectroscopy, implied that the expansion was due to protons from surface contaminants. Similar results were reported from studies of ablatively driven plasmas. In a continuation of the work, the results of time and spatially resolved spectroscopic studies of plasma formed on aluminum cathodes, yielding measurements of the expansion velocities of different components of the cathode plasma, are presented. We have heated stainless steel cathodes in situ to 700 0 C. The Hα line emission was seen to decrease by more than an order of magnitude (becoming lost in the background) when the cathodes were heated but no change in the impedance behavior was observed. Evidently the heating was insufficient to remove the last monolayer, which should contain more than enough hydrogen to close the gap. Preliminary experiments with gold-plated cathodes (which should be more resistant to chemisorption) yielded similar results. Further measurements of plasma formed on heated cathodes are presented

  5. Determination of electric field strength and kinetic temperature in the cathode fall region of a hollow cathode discharge

    Energy Technology Data Exchange (ETDEWEB)

    De la Rosa, M I; Perez, C; Gruetzmacher, K [Universidad de Valladolid, Facultad de Ciencias, 47071 Valladolid (Spain); Gonzalo, A B; Del Val, J A, E-mail: delarosa@opt.uva.e [Universidad de Salamanca, Escuela Politecnica Superior, 05003 Avila (Spain)

    2010-05-01

    In this work, we demonstrate the high potential of two-photon excitation of the 1S -2S transition of atomic hydrogen followed by optogalvanic detection, for measuring under identical experimental conditions, the kinetic temperature and the electric field strength in the cathode sheath region of a hollow cathode discharge. The first obtained results for both parameters are discussed in this paper.

  6. Geiger counters of gamma rays with a bismuth cathode; Compteurs de geiger a rayons gamma a cathode de bismuth

    Energy Technology Data Exchange (ETDEWEB)

    Meunier, R; Legrand, J P [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1953-07-01

    Geiger Muller counters present a lake of efficiency of some per cent, for the {gamma} radiations. In the region 0,3 - 1 MeV, a substantial growth of their output can be obtained by a special construction of their cathode. In accordance with previous works, we constructed some counter of formed cathode by a pleated copper wire fencing covered of Bi by electrolysis. The successive modifications brought to a cylindrical conventional cathode in sheet metal of copper, that succeeds to this type of cathode, drive to an improvement of the output. (M.B.) [French] Les compteurs de Geiger Muller presentent une efficacite assez faible de l'ordre de quelques pour cent, pour les rayonnements {gamma}. Dans la region 0,3 - 1 MeV, un accroissement substantiel de leur rendement peut etre obtenu par une construction speciale de leur cathode. Conformement a des travaux anterieurs, nous avons construit des compteurs a cathode formee par un grillage de cuivre plisse recouvert de Bi par electrolyse. Les modifications successives apportees a une cathode conventionnelle cylindrique en tole de cuivre, qui aboutissent a ce type de cathode, conduisent a une amelioration du rendement. (M.B.)

  7. A one-dimensional model illustrating virtual-cathode formation in a novel coaxial virtual-cathode oscillator.

    CSIR Research Space (South Africa)

    Turner, GR

    2014-09-01

    Full Text Available A one-dimensional electrostatic sheet model of a coaxial geometry Virtual Cathode Oscillator (VCO) is presented. The cathode is centrally located and connects to a peripherally located plate electrode to form a resonant cavity, and is thus...

  8. Air humidity and water pressure effects on the performance of air-cathode microbial fuel cell cathodes

    KAUST Repository

    Ahn, Yongtae

    2014-02-01

    To better understand how air cathode performance is affected by air humidification, microbial fuel cells were operated under different humidity conditions or water pressure conditions. Maximum power density decreased from 1130 ± 30 mW m-2 with dry air to 980 ± 80 mW m -2 with water-saturated air. When the cathode was exposed to higher water pressures by placing the cathode in a horizontal position, with the cathode oriented so it was on the reactor bottom, power was reduced for both with dry (1030 ± 130 mW m-2) and water-saturated (390 ± 190 mW m-2) air. Decreased performance was partly due to water flooding of the catalyst, which would hinder oxygen diffusion to the catalyst. However, drying used cathodes did not improve performance in electrochemical tests. Soaking the cathode in a weak acid solution, but not deionized water, mostly restored performance (960 ± 60 mW m-2), suggesting that there was salt precipitation in the cathode that was enhanced by higher relative humidity or water pressure. These results showed that cathode performance could be adversely affected by both flooding and the subsequent salt precipitation, and therefore control of air humidity and water pressure may need to be considered for long-term MFC operation. © 2013 Elsevier B.V. All rights reserved.

  9. Reliability data banks

    International Nuclear Information System (INIS)

    Cannon, A.G.; Bendell, A.

    1991-01-01

    Following an introductory chapter on Reliability, what is it, why it is needed, how it is achieved and measured, the principles of reliability data bases and analysis methodologies are the subject of the next two chapters. Achievements due to the development of data banks are mentioned for different industries in the next chapter, FACTS, a comprehensive information system for industrial safety and reliability data collection in process plants are covered next. CREDO, the Central Reliability Data Organization is described in the next chapter and is indexed separately, as is the chapter on DANTE, the fabrication reliability Data analysis system. Reliability data banks at Electricite de France and IAEA's experience in compiling a generic component reliability data base are also separately indexed. The European reliability data system, ERDS, and the development of a large data bank come next. The last three chapters look at 'Reliability data banks, - friend foe or a waste of time'? and future developments. (UK)

  10. Suncor maintenance and reliability

    Energy Technology Data Exchange (ETDEWEB)

    Little, S. [Suncor Energy, Calgary, AB (Canada)

    2006-07-01

    Fleet maintenance and reliability at Suncor Energy was discussed in this presentation, with reference to Suncor Energy's primary and support equipment fleets. This paper also discussed Suncor Energy's maintenance and reliability standard involving people, processes and technology. An organizational maturity chart that graphed organizational learning against organizational performance was illustrated. The presentation also reviewed the maintenance and reliability framework; maintenance reliability model; the process overview of the maintenance and reliability standard; a process flow chart of maintenance strategies and programs; and an asset reliability improvement process flow chart. An example of an improvement initiative was included, with reference to a shovel reliability review; a dipper trip reliability investigation; bucket related failures by type and frequency; root cause analysis of the reliability process; and additional actions taken. Last, the presentation provided a graph of the results of the improvement initiative and presented the key lessons learned. tabs., figs.

  11. Cationic fluorinated polymer binders for microbial fuel cell cathodes

    KAUST Repository

    Chen, Guang; Wei, Bin; Logan, Bruce E.; Hickner, Michael A.

    2012-01-01

    Fluorinated quaternary ammonium-containing polymers were used as catalyst binders in microbial fuel cell (MFC) cathodes. The performance of the cathodes was examined and compared to NAFION ® and other sulfonated aromatic cathode catalyst binders using linear sweep voltammetry (LSV), impedance spectroscopy, and performance tests in single chamber air-cathode MFCs. The cathodes with quaternary ammonium functionalized fluorinated poly(arylene ether) (Q-FPAE) binders showed similar current density and charge transfer resistance (R ct) to cathodes with NAFION ® binders. Cathodes containing either of these fluorinated binders exhibited better electrochemical responses than cathodes with sulfonated or quaternary ammonium-functionalized RADEL ® poly(sulfone) (S-Radel or Q-Radel) binders. After 19 cycles (19 d), the power densities of all the MFCs declined compared to the initial cycles due to biofouling at the cathode. MFC cathodes with fluorinated polymer binders (1445 mW m -2, Q-FPAE-1.4-H; 1397 mW m -2, Q-FPAE-1.4-Cl; 1277 mW m -2, NAFION ®; and 1256 mW m -2, Q-FPAE-1.0-Cl) had better performance than those with non-fluorinated polymer binders (880 mW m -2, S-Radel; 670 mW m -2, Q-Radel). There was a 15% increase in the power density using the Q-FPAE binder with a 40% higher ion exchange capacity (Q-FPAE-1.4-H compared to Q-FPAE-1.0-Cl) after 19 cycles of operation, but there was no effect on the power production due to counter ions in the binder (Cl -vs. HCO 3 -). The highest-performance cathodes (NAFION ® and Q-FPAE binders) had the lowest charge transfer resistances (R ct) in fresh and in fouled cathodes despite the presence of thick biofilms on the surface of the electrodes. These results show that fluorinated binders may decrease the penetration of the biofilm and associated biopolymers into the cathode structure, which helps to combat MFC performance loss over time. © 2012 The Royal Society of Chemistry.

  12. The Accelerator Reliability Forum

    CERN Document Server

    Lüdeke, Andreas; Giachino, R

    2014-01-01

    A high reliability is a very important goal for most particle accelerators. The biennial Accelerator Reliability Workshop covers topics related to the design and operation of particle accelerators with a high reliability. In order to optimize the over-all reliability of an accelerator one needs to gather information on the reliability of many different subsystems. While a biennial workshop can serve as a platform for the exchange of such information, the authors aimed to provide a further channel to allow for a more timely communication: the Particle Accelerator Reliability Forum [1]. This contribution will describe the forum and advertise it’s usage in the community.

  13. Catadioptric aberration correction in cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M. [IBM T.J. Watson Research Center, PO Box 218, Yorktown Heights, NY 10598 (United States); Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-04-15

    In this paper I briefly review the use of electrostatic electron mirrors to correct the aberrations of the cathode lens objective lens in low energy electron microscope (LEEM) and photo electron emission microscope (PEEM) instruments. These catadioptric systems, combining electrostatic lens elements with a reflecting mirror, offer a compact solution, allowing simultaneous and independent correction of both spherical and chromatic aberrations. A comparison with catadioptric systems in light optics informs our understanding of the working principles behind aberration correction with electron mirrors, and may point the way to further improvements in the latter. With additional developments in detector technology, 1 nm spatial resolution in LEEM appears to be within reach. - Highlights: • The use of electron mirrors for aberration correction in LEEM/PEEM is reviewed. • A comparison is made with similar systems in light optics. • Conditions for 1 nm spatial resolution are discussed.

  14. Cathodic Vacuum Arc Plasma of Thallium

    International Nuclear Information System (INIS)

    Yushkov, Georgy Yu.; Anders, Andre

    2006-01-01

    Thallium arc plasma was investigated in a vacuum arc ion source. As expected from previous consideration of cathode materials in the Periodic Table of the Elements, thallium plasma shows lead-like behavior. Its mean ion charge state exceeds 2.0 immediately after arc triggering, reaches the predicted 1.60 and 1.45 after about 100 microsec and 150 microsec, respectively. The most likely ion velocity is initially8000 m/s and decays to 6500 m/s and 6200 m/s after 100 microsec and 150microsec, respectively. Both ion charge states and ion velocities decay further towards steady state values, which are not reached within the 300microsec pulses used here. It is argued that the exceptionally high vapor pressure and charge exchange reactions are associated with the establishment of steady state ion values

  15. Properties of cathode materials in alkaline cells

    International Nuclear Information System (INIS)

    Salkind, A.J.; McBreen, J.; Freeman, R.; Parkhurst, W.A.

    1985-01-01

    Conventional and new cathode materials in primary and secondary alkaline cells were investigated for stability, structure, electrochemical reversibility and efficiency. Included were various forms of AgO for reserve-type silver-zinc batteries, a new material - AgNiO/sub 2/ - and several nickel electrodes for nickel-cadmium and nickel-hydrogen cells for aerospace applications. A comparative study was made of the stability of electroformed and chemically prepared AgO. Stability was correlated with impurities detected by XPS and SAM. After the first discharge AgNiO/sub 2/ can be recharged to the monovalent level. The discharge product is predominantly silver. Plastic-bonded nickel electrodes display a second plateau on discharge. Additions of Co(OH)/sub 2/ largely eliminate this

  16. Carbon nanowalls in field emission cathodes

    Directory of Open Access Journals (Sweden)

    Belyanin A. F.

    2017-12-01

    Full Text Available The carbon nanowall (CNW layers were grown from a gas mixture of hydrogen and methane, activated by a DC glow discharge, on Si substrates (Si/CNW layered structure. The second layer of CNW was grown either on the first layer (Si/CNW/CNW structure or on Ni or NiO films deposited on the first CNW layer (Si/CNW/Ni/CNW and Si/CNW/NiO/CNW structures. The composition and structure of the resulting layered structures were studied using scanning electron microscopy, Raman spectroscopy, and X-ray diffractometry. It was found that annealing of Si/CNW structure in vacuum, growing of the second CNW layer on Si/CNW, as well as deposition of Ni or NiO films prior to the growing of the second CNW layer improve functional properties of field emission cathodes based on the electron-emitting CNW layers.

  17. Olivine-type cathodes. Achievements and problems

    Science.gov (United States)

    Yamada, Atsuo; Hosoya, Mamoru; Chung, Sai-Cheong; Kudo, Yoshihiro; Hinokuma, Koichiro; Liu, Kuang-Yu; Nishi, Yoshio

    The recent progress at Sony in the design of practical olivine-type cathodes is reviewed briefly. First principle calculations revealed LiFePO 4 is a semiconductor with ca. 0.3 eV band gap and LiMnPO 4 is an insulator with ca. 2 eV band gap, which seems the major intrinsic obstacle to a smooth redox reaction at 4 V in the Mn-rich phase. Attention is also focused on the lattice frustration induced by the strong electron (Mn 3+: 3d 4-e gσ ∗)-lattice interaction (Jahn-Teller effect) in the charged state of Li(Mn yFe 1- y)PO 4 (0≤ y≤1). Dense nanocomposite formation with disordered conductive carbon as well as the choice of the appropriate synthetic precursors is highlighted as important engineering aspects, followed by some specific issues concerning tolerance to unusual conditions.

  18. Uranium vapor generator: pulsed hollow cathode lamp

    International Nuclear Information System (INIS)

    Carleer, M.; Gagne, J.; Leblanc, B.; Demers, Y.; Mongeau, B.

    1979-01-01

    The production of uranium vapors has been studied in the 5 L 0 6 ground state using a pulsed hollow cathode lamp. The evolution of the 238 U ( 5 L 0 6 ) concentration with time has been studied with Xe and Ar as buffer gases. A density of 2.7 x 10 13 atoms cm -3 was obtained with Xe as a buffer gas. In addition, those measurements, obtained from the absorption of a laser beam tuned to the 5758.143 A ( 5 L 0 6 -17,361 7 L 6 ) transition, allowed the determination of the transition probability A=2.1 x 10 5 sec -1 and of the branching ratio BR=0.08 for this transition

  19. Using cathode spacers to minimize reactor size in air cathode microbial fuel cells

    KAUST Repository

    Yang, Qiao

    2012-04-01

    Scaling up microbial fuel cells (MFCs) will require more compact reactor designs. Spacers can be used to minimize the reactor size without adversely affecting performance. A single 1.5mm expanded plastic spacer (S1.5) produced a maximum power density (973±26mWm -2) that was similar to that of an MFC with the cathode exposed directly to air (no spacer). However, a very thin spacer (1.3mm) reduced power by 33%. Completely covering the air cathode with a solid plate did not eliminate power generation, indicating oxygen leakage into the reactor. The S1.5 spacer slightly increased columbic efficiencies (from 20% to 24%) as a result of reduced oxygen transfer into the system. Based on operating conditions (1000ς, CE=20%), it was estimated that 0.9Lh -1 of air would be needed for 1m 2 of cathode area suggesting active air flow may be needed for larger scale MFCs. © 2012 Elsevier Ltd.

  20. An experimental study of molten salt electrorefining of uranium using solid iron cathode and liquid cadmium cathode for development of pyrometallurgical reprocessing

    International Nuclear Information System (INIS)

    Koyama, Tadafumi; Iizuka, Masatoshi; Tanaka, Hiroshi; Tokiwai, Moriyasu; Shoji, Yuichi; Fujita, Reiko; Kobayashi, Tsuguyuki.

    1997-01-01

    Electrorefining of uranium was studied for developing pyrometallurgical reprocessing technology of metal fuel cycle. After concentration dependence of polarization curve was measured, uranium was electrodeposited either on solid iron cathode or in liquid cadmium cathode. Design and operational conditions of the cathode were improved for obtaining much greater quantity of deposit, resulting in recovery of 732g of dendritic uranium on a single solid cathode, and of 232g of uranium in 2,344g of a liquid cadmium cathode. The behaviors of electro-codeposition of rare earth elements with uranium were observed for liquid cadmium cathode, and were found to follow the local equilibrium between salt electrolyte and cathode. The decontamination factors of FP simulating elements from uranium were tentatively determined as >2,000 for deposition to solid cathode and as >7 for deposition to liquid cadmium cathode, respectively. (author)

  1. Relative accuracy and availability of an Irish National Database of dispensed medication as a source of medication history information: observational study and retrospective record analysis.

    LENUS (Irish Health Repository)

    Grimes, T

    2013-01-27

    WHAT IS KNOWN AND OBJECTIVE: The medication reconciliation process begins by identifying which medicines a patient used before presentation to hospital. This is time-consuming, labour intensive and may involve interruption of clinicians. We sought to identify the availability and accuracy of data held in a national dispensing database, relative to other sources of medication history information. METHODS: For patients admitted to two acute hospitals in Ireland, a Gold Standard Pre-Admission Medication List (GSPAML) was identified and corroborated with the patient or carer. The GSPAML was compared for accuracy and availability to PAMLs from other sources, including the Health Service Executive Primary Care Reimbursement Scheme (HSE-PCRS) dispensing database. RESULTS: Some 1111 medication were assessed for 97 patients, who were median age 74 years (range 18-92 years), median four co-morbidities (range 1-9), used median 10 medications (range 3-25) and half (52%) were male. The HSE-PCRS PAML was the most accurate source compared to lists provided by the general practitioner, community pharmacist or cited in previous hospital documentation: the list agreed for 74% of the medications the patients actually used, representing complete agreement for all medications in 17% of patients. It was equally contemporaneous to other sources, but was less reliable for male than female patients, those using increasing numbers of medications and those using one or more item that was not reimbursable by the HSE. WHAT IS NEW AND CONCLUSION: The HSE-PCRS database is a relatively accurate, available and contemporaneous source of medication history information and could support acute hospital medication reconciliation.

  2. Study of the hollow cathode plasma electron-gun

    International Nuclear Information System (INIS)

    Zhang Yonghui; Jiang Jinsheng; Chang Anbi

    2003-01-01

    For developing a novel high-current, long pulse width electron source, the theoretics and mechanism of the hollow cathode plasma electron-gun are analyzed in detail in this paper, the structure and the physical process of hollow cathode plasma electron-gun are also studied. This gun overcomes the limitations of most high-power microwave tubes, which employ either thermionic cathodes that produce low current-density beams because of the limitation of the space charge, or field-emission cathodes that offer high current density but provide only short pulse width because of plasma closure of the accelerating gap. In the theories studying on hollow cathode plasma electron-gun, the characteristic of the hollow-cathode discharge is introduced, the action during the forming of plasma of the stimulating electrode and the modulating anode are discussed, the movement of electrons and ions and the primary parameters are analyzed, and the formulas of the electric field, beam current density and the stabilization conditions of the beam current are also presented in this paper. The numerical simulation is carried out based on Poisson's equation, and the equations of current continuity and movement. And the optimized result is reported. On this basis, we have designed a hollow-cathode-plasma electron-gun, whose output pulse current is 2 kA, and pulse width is 1 microsecond

  3. Oxide Fiber Cathode Materials for Rechargeable Lithium Cells

    Science.gov (United States)

    Rice, Catherine E.; Welker, Mark F.

    2008-01-01

    LiCoO2 and LiNiO2 fibers have been investigated as alternatives to LiCoO2 and LiNiO2 powders used as lithium-intercalation compounds in cathodes of rechargeable lithium-ion electrochemical cells. In making such a cathode, LiCoO2 or LiNiO2 powder is mixed with a binder [e.g., poly(vinylidene fluoride)] and an electrically conductive additive (usually carbon) and the mixture is pressed to form a disk. The binder and conductive additive contribute weight and volume, reducing the specific energy and energy density, respectively. In contrast, LiCoO2 or LiNiO2 fibers can be pressed and sintered to form a cathode, without need for a binder or a conductive additive. The inter-grain contacts of the fibers are stronger and have fewer defects than do those of powder particles. These characteristics translate to increased flexibility and greater resilience on cycling and, consequently, to reduced loss of capacity from cycle to cycle. Moreover, in comparison with a powder-based cathode, a fiber-based cathode is expected to exhibit significantly greater ionic and electronic conduction along the axes of the fibers. Results of preliminary charge/discharge-cycling tests suggest that energy densities of LiCoO2- and LiNiO2-fiber cathodes are approximately double those of the corresponding powder-based cathodes.

  4. High Performance Cathodes for Li-Air Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Xing, Yangchuan

    2013-08-22

    The overall objective of this project was to develop and fabricate a multifunctional cathode with high activities in acidic electrolytes for the oxygen reduction and evolution reactions for Li-air batteries. It should enable the development of Li-air batteries that operate on hybrid electrolytes, with acidic catholytes in particular. The use of hybrid electrolytes eliminates the problems of lithium reaction with water and of lithium oxide deposition in the cathode with sole organic electrolytes. The use of acid electrolytes can eliminate carbonate formation inside the cathode, making air breathing Li-air batteries viable. The tasks of the project were focused on developing hierarchical cathode structures and bifunctional catalysts. Development and testing of a prototype hybrid Li-air battery were also conducted. We succeeded in developing a hierarchical cathode structure and an effective bifunctional catalyst. We accomplished integrating the cathode with existing anode technologies and made a pouch prototype Li-air battery using sulfuric acid as catholyte. The battery cathodes contain a nanoscale multilayer structure made with carbon nanotubes and nanofibers. The structure was demonstrated to improve battery performance substantially. The bifunctional catalyst developed contains a conductive oxide support with ultra-low loading of platinum and iridium oxides. The work performed in this project has been documented in seven peer reviewed journal publications, five conference presentations, and filing of two U.S. patents. Technical details have been documented in the quarterly reports to DOE during the course of the project.

  5. Self-organization in cathode boundary layer discharges in xenon

    International Nuclear Information System (INIS)

    Takano, Nobuhiko; Schoenbach, Karl H

    2006-01-01

    Self-organization of direct current xenon microdischarges in cathode boundary layer configuration has been studied for pressures in the range 30-140 Torr and for currents in the range 50 μA-1 mA. Side-on and end-on observations of the discharge have provided information on the structure and spatial arrangement of the plasma filaments. The regularly spaced filaments, which appear in the normal glow mode when the current is lowered, have a length which is determined by the cathode fall. It varies, dependent on pressure and current, between 50 and 70 μm. The minimum diameter is approximately 80 μm, as determined from the radiative emission in the visible. The filaments are sources of extensive excimer emission. Measurements of the cathode fall length have allowed us to determine the secondary emission coefficient for the discharge in the normal glow mode and to estimate the cathode fall voltage at the transition from normal glow mode to filamentary mode. It was found that the cathode fall voltage at this transition decreases, indicating the onset of additional electron gain processes at the cathode. The regular arrangement of the filaments, self-organization, is assumed to be due to Coulomb interactions between the positively charged cathode fall channels and positive space charges on the surface of the surrounding dielectric spacer. Calculations based on these assumptions showed good agreement with experimentally observed filament patterns

  6. Neutral hydrophilic cathode catalyst binders for microbial fuel cells

    KAUST Repository

    Saito, Tomonori

    2011-01-01

    Improving oxygen reduction in microbial fuel cell (MFC) cathodes requires a better understanding of the effects of the catalyst binder chemistry and properties on performance. A series of polystyrene-b-poly(ethylene oxide) (PS-b-PEO) polymers with systematically varying hydrophilicity were designed to determine the effect of the hydrophilic character of the binder on cathode performance. Increasing the hydrophilicity of the PS-b-PEO binders enhanced the electrochemical response of the cathode and MFC power density by ∼15%, compared to the hydrophobic PS-OH binder. Increased cathode performance was likely a result of greater water uptake by the hydrophilic binder, which would increase the accessible surface area for oxygen reduction. Based on these results and due to the high cost of PS-b-PEO, the performance of an inexpensive hydrophilic neutral polymer, poly(bisphenol A-co-epichlorohydrin) (BAEH), was examined in MFCs and compared to a hydrophilic sulfonated binder (Nafion). MFCs with BAEH-based cathodes with two different Pt loadings initially (after 2 cycles) had lower MFC performance (1360 and 630 mW m-2 for 0.5 and 0.05 mg Pt cm-2) than Nafion cathodes (1980 and 1080 mW m -2 for 0.5 and 0.05 mg Pt cm-2). However, after long-term operation (22 cycles, 40 days), power production of each cell was similar (∼1200 and 700-800 mW m-2 for 0.5 and 0.05 mg Pt cm-2) likely due to cathode biofouling that could not be completely reversed through physical cleaning. While binder chemistry could improve initial electrochemical cathode performance, binder materials had less impact on overall long-term MFC performance. This observation suggests that long-term operation of MFCs will require better methods to avoid cathode biofouling. © 2011 The Royal Society of Chemistry.

  7. Human Reliability Program Overview

    Energy Technology Data Exchange (ETDEWEB)

    Bodin, Michael

    2012-09-25

    This presentation covers the high points of the Human Reliability Program, including certification/decertification, critical positions, due process, organizational structure, program components, personnel security, an overview of the US DOE reliability program, retirees and academia, and security program integration.

  8. Power electronics reliability analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Mark A.; Atcitty, Stanley

    2009-12-01

    This report provides the DOE and industry with a general process for analyzing power electronics reliability. The analysis can help with understanding the main causes of failures, downtime, and cost and how to reduce them. One approach is to collect field maintenance data and use it directly to calculate reliability metrics related to each cause. Another approach is to model the functional structure of the equipment using a fault tree to derive system reliability from component reliability. Analysis of a fictitious device demonstrates the latter process. Optimization can use the resulting baseline model to decide how to improve reliability and/or lower costs. It is recommended that both electric utilities and equipment manufacturers make provisions to collect and share data in order to lay the groundwork for improving reliability into the future. Reliability analysis helps guide reliability improvements in hardware and software technology including condition monitoring and prognostics and health management.

  9. Reliability of software

    International Nuclear Information System (INIS)

    Kopetz, H.

    1980-01-01

    Common factors and differences in the reliability of hardware and software; reliability increase by means of methods of software redundancy. Maintenance of software for long term operating behavior. (HP) [de

  10. Reliable Design Versus Trust

    Science.gov (United States)

    Berg, Melanie; LaBel, Kenneth A.

    2016-01-01

    This presentation focuses on reliability and trust for the users portion of the FPGA design flow. It is assumed that the manufacturer prior to hand-off to the user tests FPGA internal components. The objective is to present the challenges of creating reliable and trusted designs. The following will be addressed: What makes a design vulnerable to functional flaws (reliability) or attackers (trust)? What are the challenges for verifying a reliable design versus a trusted design?

  11. Pocket Handbook on Reliability

    Science.gov (United States)

    1975-09-01

    exponencial distributions Weibull distribution, -xtimating reliability, confidence intervals, relia- bility growth, 0. P- curves, Bayesian analysis. 20 A S...introduction for those not familiar with reliability and a good refresher for those who are currently working in the area. LEWIS NERI, CHIEF...includes one or both of the following objectives: a) prediction of the current system reliability, b) projection on the system reliability for someI future

  12. Resonant cavity operation of a virtual cathode oscillator

    International Nuclear Information System (INIS)

    Fazio, M.V.; Hoeberling, R.F.

    1986-01-01

    Gigawatt level virtual cathode sources have been proposed for several applications. These include microwave weapons and drivers for high-energy particle accelerators. Both of these require a microwave source with very high power output that is controllable in frequency and phase. A conventional virtual cathode oscillator will not meet these requirements. The addition of a resonant cavity surrounding the oscillating virtual cathode either alone or pumped with a low-power injection signal, causing it to operate as an amplifier, could greatly influence the performance of this type of source making it more practical for accelerator and weapon applications. The progress on an experiment to test these concepts will be discussed

  13. Iron phosphate materials as cathodes for lithium batteries

    CERN Document Server

    Prosini, Pier Paolo

    2011-01-01

    ""Iron Phosphate Materials as Cathodes for Lithium Batteries"" describes the synthesis and the chemical-physical characteristics of iron phosphates, and presents methods of making LiFePO4 a suitable cathode material for lithium-ion batteries. The author studies carbon's ability to increase conductivity and to decrease material grain size, as well as investigating the electrochemical behaviour of the materials obtained. ""Iron Phosphate Materials as Cathodes for Lithium Batteries"" also proposes a model to explain lithium insertion/extraction in LiFePO4 and to predict voltage profiles at variou

  14. Cathodic corrosion protection of steel pipes; Kathodischer Korrosionsschutz von Rohrleitungsstaehlen

    Energy Technology Data Exchange (ETDEWEB)

    Buechler, Markus [SGK Schweizerische Gesellschaft fuer Korrosionsschutz, Zuerich (Switzerland); Schoeneich, Hanns-Georg [Open Grid Europe, Essen (Germany)

    2011-07-01

    The cathodic corrosion protection has been proven excellently in the practical use for buried steel pipelines. This is evidenced statistically by a significantly less frequency of loss compared to non-cathodically protected pipelines. Based on thermodynamic considerations, the authors of the contribution under consideration describe the operation of the cathodic corrosion protection and regular adjustment of the electrochemical potential at the interface steel / soil in practical use. Subsequently, the corrosion scenarios are discussed that may occur when an incorrect setting of the potential results from an operation over several decades. This incorrect setting also can be caused by the failure of individual components of the corrosion protection.

  15. Operation and Applications of the Boron Cathodic Arc Ion Source

    International Nuclear Information System (INIS)

    Williams, J. M.; Freeman, J. H.; Klepper, C. C.; Chivers, D. J.; Hazelton, R. C.

    2008-01-01

    The boron cathodic arc ion source has been developed with a view to several applications, particularly the problem of shallow junction doping in semiconductors. Research has included not only development and operation of the boron cathode, but other cathode materials as well. Applications have included a large deposition directed toward development of a neutron detector and another deposition for an orthopedic coating, as well as the shallow ion implantation function. Operational experience is described and information pertinent to commercial operation, extracted from these experiments, is presented.

  16. Understanding the Role of Accredited Drug Dispensing Outlets in Tanzania's Health System.

    Directory of Open Access Journals (Sweden)

    Martha Embrey

    Full Text Available People in many low-income countries access medicines from retail drug shops. In Tanzania, a public-private partnership launched in 2003 used an accreditation approach to improve access to quality medicines and pharmaceutical services in underserved areas. The government scaled up the accredited drug dispensing outlet (ADDO program nationally, with over 9,000 shops now accredited. This study assessed the relationships between community members and their sources of health care and medicines, particularly antimicrobials, with a specific focus on the role ADDOs play in the health care system.Using mixed methods, we collected data in four regions. We surveyed 1,185 households and audited 96 ADDOs and 84 public/nongovernmental health facilities using a list of 17 tracer drugs. To determine practices in health facilities, we interviewed 1,365 exiting patients. To assess dispensing practices, mystery shoppers visited 306 ADDOs presenting one of three scenarios (102 each about a child's respiratory symptoms.Of 614 household members with a recent acute illness, 73% sought outside care-30% at a public facility and 31% at an ADDO. However, people bought medicines more often at ADDOs no matter who recommended the treatment; of the 581 medicines that people had received, 49% came from an ADDO. Although health facilities and ADDOs had similar availability of antimicrobials, ADDOs had more pediatric formulations available (p<0.001. The common perception was that drugs from ADDOs are more expensive, but the difference in the median cost to treat pneumonia was relatively minimal (US$0.26 in a public facility and US$0.30 in an ADDO. Over 20% of households said they had someone with a chronic condition, with 93% taking medication, but ADDOs are allowed to sell very few chronic care-related medicines. ADDO dispensers are trained to refer complicated cases to a health facility, and notably, 99% of mystery shoppers presenting a pneumonia scenario received an

  17. Principles of Bridge Reliability

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle; Nowak, Andrzej S.

    The paper gives a brief introduction to the basic principles of structural reliability theory and its application to bridge engineering. Fundamental concepts like failure probability and reliability index are introduced. Ultimate as well as serviceability limit states for bridges are formulated......, and as an example the reliability profile and a sensitivity analyses for a corroded reinforced concrete bridge is shown....

  18. Reliability in engineering '87

    International Nuclear Information System (INIS)

    Tuma, M.

    1987-01-01

    The participants heard 51 papers dealing with the reliability of engineering products. Two of the papers were incorporated in INIS, namely ''Reliability comparison of two designs of low pressure regeneration of the 1000 MW unit at the Temelin nuclear power plant'' and ''Use of probability analysis of reliability in designing nuclear power facilities.''(J.B.)

  19. Erosion behavior of composite Al-Cr cathodes in cathodic arc plasmas in inert and reactive atmospheres

    Energy Technology Data Exchange (ETDEWEB)

    Franz, Robert, E-mail: robert.franz@unileoben.ac.at; Mendez Martin, Francisca; Hawranek, Gerhard [Montanuniversität Leoben, Franz-Josef-Strasse 18, 8700 Leoben (Austria); Polcik, Peter [Plansee Composite Materials GmbH, Siebenbürgerstrasse 23, 86983 Lechbruck am See (Germany)

    2016-03-15

    Al{sub x}Cr{sub 1−x} composite cathodes with Al contents of x = 0.75, 0.5, and 0.25 were exposed to cathodic arc plasmas in Ar, N{sub 2}, and O{sub 2} atmospheres and their erosion behavior was studied. Cross-sectional analysis of the elemental distribution of the near-surface zone in the cathodes by scanning electron microscopy revealed the formation of a modified layer for all cathodes and atmospheres. Due to intermixing of Al and Cr in the heat-affected zone, intermetallic Al-Cr phases formed as evidenced by x-ray diffraction analysis. Cathode poisoning effects in the reactive N{sub 2} and O{sub 2} atmospheres were nonuniform as a result of the applied magnetic field configuration. With the exception of oxide islands on Al-rich cathodes, reactive layers were absent in the circular erosion zone, while nitrides and oxides formed in the less eroded center region of the cathodes.

  20. ASHP national survey of pharmacy practice in hospital settings: Dispensing and administration--2014.

    Science.gov (United States)

    Pedersen, Craig A; Schneider, Philip J; Scheckelhoff, Douglas J

    2015-07-01

    The results of the 2014 ASHP national survey of pharmacy practice in hospital settings that pertain to dispensing and administration are described. A stratified random sample of pharmacy directors at 1435 general and children's medical-surgical hospitals in the United States were surveyed by mail. In this national probability sample survey, the response rate was 29.7%. Ninety-seven percent of hospitals used automated dispensing cabinets in their medication distribution systems, 65.7% of which used individually secured lidded pockets as the predominant configuration. Overall, 44.8% of hospitals used some form of machine-readable coding to verify doses before dispensing in the pharmacy. Overall, 65% of hospital pharmacy departments reported having a cleanroom compliant with United States Pharmacopeia chapter 797. Pharmacists reviewed and approved all medication orders before the first dose was administered, either onsite or by remote order view, except in procedure areas and emergency situations, in 81.2% of hospitals. Adoption rates of electronic health information have rapidly increased, with the widespread use of electronic health records, computer prescriber order entry, barcodes, and smart pumps. Overall, 31.4% of hospitals had pharmacists practicing in ambulatory or primary care clinics. Transitions-of-care services offered by the pharmacy department have generally increased since 2012. Discharge prescription services increased from 11.8% of hospitals in 2012 to 21.5% in 2014. Approximately 15% of hospitals outsourced pharmacy management operations to a contract pharmacy services provider, an increase from 8% in 2011. Health-system pharmacists continue to have a positive impact on improving healthcare through programs that improve the efficiency, safety, and clinical outcomes of medication use in health systems. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  1. Polymer dispensing and embossing technology for the lens type LED packaging

    Science.gov (United States)

    Chien, Chien-Lin Chang; Huang, Yu-Che; Hu, Syue-Fong; Chang, Chung-Min; Yip, Ming-Chuen; Fang, Weileun

    2013-06-01

    This study presents a ring-type micro-structure design on the substrate and its corresponding micro fabrication processes for a lens-type light-emitting diode (LED) package. The dome-type or crater-type silicone lenses are achieved by a dispensing and embossing process rather than a molding process. Silicone with a high viscosity and thixotropy index is used as the encapsulant material. The ring-type micro structure is adopted to confine the dispensed silicone encapsulant so as to form the packaged lens. With the architecture and process described, this LED package technology herein has three merits: (1) the flexibility of lens-type LED package designs is enhanced; (2) a dome-type package design is used to enhance the intensity; (3) a crater-type package design is used to enhance the view angle. Measurement results show the ratio between the lens height and lens radius can vary from 0.4 to 1 by changing the volume of dispensed silicone. The view angles of dome-type and crater-type packages can reach 155° ± 5° and 175° ± 5°, respectively. As compared with the commercial plastic leaded chip carrier-type package, the luminous flux of a monochromatic blue light LED is improved by 15% by the dome-type package (improved by 7% by the crater-type package) and the luminous flux of a white light LED is improved by 25% by the dome-type package (improved by 13% by the crater-type package). The luminous flux of monochromatic blue light LED and white light LED are respectively improved by 8% and 12% by the dome-type package as compare with the crater-type package.

  2. Steam sterilization and automatic dispensing of [{sup 18}F]fludeoxyglucose (FDG) for injection

    Energy Technology Data Exchange (ETDEWEB)

    Karwath, Pascal [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany); Sartor, Johannes [MC-Pharma GmbH (MCP), Bonn (Germany); Gries, Wolfgang [MC-Pharma GmbH (MCP), Bonn (Germany); Wodarski, Christine [MC-Pharma GmbH (MCP), Bonn (Germany); Dittmar, Claus [MC-Pharma GmbH (MCP), Bonn (Germany); Biersack, Hans J [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Guhlke, Stefan [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany)

    2005-04-01

    For the purpose of implementing steam sterilization of 2-[{sup 18}F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity ({approx}99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories.

  3. Steam sterilization and automatic dispensing of [18F]fludeoxyglucose (FDG) for injection

    International Nuclear Information System (INIS)

    Karwath, Pascal; Sartor, Johannes; Gries, Wolfgang; Wodarski, Christine; Dittmar, Claus; Biersack, Hans J.; Guhlke, Stefan

    2005-01-01

    For the purpose of implementing steam sterilization of 2-[ 18 F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity (∼99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories

  4. Evaluation of antibiotics dispensing profile in Tubarão, Santa Catarina, Brazil

    Directory of Open Access Journals (Sweden)

    Claudia Rauber

    2009-12-01

    Full Text Available Antibiotics are drugs widely used in prophylaxis and treatment of a great number of diseases. However, their use must be carefully controlled as acquisition in pharmacies, often without medical prescription, is elevated. The role of pharmacists in these circumstances is to practice dispensation in a rational manner. Through a structured questionnaire with open and closed questions, this study investigated the profile of antibiotics dispensed in pharmacies of Tubarão, Santa Catarina, Brazil. From the responses, it was observed that 85.0% dispense this class of medicine without medical prescription, mainly for treatment of respiratory (62.8% and urinary (12.0% tract disorders. Moreover, pharmacists' guidance was largely focused on posology (66.6% and drug interaction (12.6%, in addition to the interactions with contraceptives, alcohol and milk. The importance of avoiding antibiotics dispensation without medical prescription must be emphasized, as well as the benefits of educating the population to promote the rational use of medicines.Antibióticos são fármacos amplamente utilizados na profilaxia e no tratamento de grande número de doenças. Entretanto, seu uso deve ser cuidadosamente controlado nas farmácias, uma vez que nestas a aquisição sem prescrição médica é elevada. O papel dos farmacêuticos nessas circunstâncias é o de praticar a dispensação de maneira racional. Por meio de questionário estruturado, com questões abertas e fechadas, investigou-se o perfil dos antibióticos dispensados em farmácias de Tubarão, Santa Catarina, Brasil. Pelas respostas, observou-se que 85% das dispensa essa classe de medicamentos sem prescrição médica, principalmente para o tratamento de problemas dos tratos respiratório (62,8% e urinário (12,0%. Além disso, a orientação dos farmacêuticos se focou amplamente na posologia (66,6%e nas interações com fármacos (12,6%, em adição às interações com anticoncepcionais, álcool e

  5. A model for drug dispensing service based on the care process in the Brazilian health system

    Directory of Open Access Journals (Sweden)

    Luciano Soares

    2013-03-01

    Full Text Available Access to medication emphasizes the availability of the product at the expense of providing a service. The goal of this paper is to propose a theoretical model for a drug dispensing service, beginning with a reflection on the current realities of the Unified Health System and drug dispensation in Brazil. A conceptual analytical research made by a methodological course called disciplined imagination was mainly the approach applied to develop the model. The drug dispensing service is part of the care process, which considers access as an attribute; reception, connection and accountability, management, and clinical pharmaceutical aspects as components; and the rational use of drugs as the purpose. The proposed model addresses access to the dispensing service and demands a reorientation of routines, instruments, and practices.O acesso a medicamentos enfatiza a disponibilidade do produto em detrimento da provisão de um serviço. O objetivo deste trabalho é propor um modelo teórico para um serviço de dispensação de medicamentos, iniciando com uma reflexão sobre a realidade atual do Sistema Único de Saúde e a dispensação de medicamentos no Brasil. Uma pesquisa analítica conceitual realizada por meio de um percurso metodológico chamado de imaginação disciplinada constituiu a estratégia principal para o desenvolvimento do modelo. O serviço de dispensação é parte do processo de cuidado, o qual considera o acesso como um atributo; os aspectos acolhimento, vínculo e responsabilização, gestão e clínica farmacêutica como componentes e o uso racional de medicamentos como o propósito. O modelo proposto direciona o acesso para o serviço de dispensação e demanda a reorientação de rotinas, instrumentos e práticas.

  6. Gene disruption reveals a dispensable role for plasmepsin VII in the Plasmodium berghei life cycle.

    Science.gov (United States)

    Mastan, Babu S; Kumari, Anchala; Gupta, Dinesh; Mishra, Satish; Kumar, Kota Arun

    2014-06-01

    Plasmepsins (PM), aspartic proteases of Plasmodium, comprises a family of ten proteins that perform critical functions in Plasmodium life cycle. Except VII and VIII, functions of the remaining plasmepsin members have been well characterized. Here, we have generated a mutant parasite lacking PM VII in Plasmodium berghei using reverse genetics approach. Systematic comparison of growth kinetics and infection in both mosquito and vertebrate host revealed that PM VII depleted mutants exhibited no defects in development and progressed normally throughout the parasite life cycle. These studies suggest a dispensable role for PM VII in Plasmodium berghei life cycle. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Drug dispensing practices at pharmacies in Bengaluru: A cross-sectional study

    OpenAIRE

    R Soumya; Vijayalakshmi Devarashetty; C R Jayanthi; M Sushma

    2016-01-01

    Objectives: Pharmacists are one of the crucial focal points for health care in the community. They have tremendous outreach to the public as pharmacies are often the first-port-of-call. With the increase of ready-to-use drugs, the main health-related activity of a pharmacist today is to assure the quality of dispensing, a key element to promote rational medicine use. Materials and Methods: A cross-sectional study of 200 pharmacies, 100 each in various residential (R) and commercial (C) areas ...

  8. International Space Station (ISS) Potable Water Dispenser (PWD) Beverage Adapter (BA) Redesign

    Science.gov (United States)

    Edgerly, Rachel; Benoit, Jace; Shindo, David

    2012-01-01

    The Potable Water Dispenser used on the International Space Station (ISS) interfaces with food and drink packages using the Beverage Adapter and Needle. Unexpected leakage has been seen in this interface. The Beverage Adapter used on ]orbit was returned to the ground for Test, Teardown, and Evaluation. The results of that investigation prompted a redesign of the Beverage Adapter and Needle. The Beverage Adapter materials were changed to be more corrosion resistant, and the Needle was redesigned to preclude leakage. The redesigns have been tested and proven.

  9. Reliable computer systems.

    Science.gov (United States)

    Wear, L L; Pinkert, J R

    1993-11-01

    In this article, we looked at some decisions that apply to the design of reliable computer systems. We began with a discussion of several terms such as testability, then described some systems that call for highly reliable hardware and software. The article concluded with a discussion of methods that can be used to achieve higher reliability in computer systems. Reliability and fault tolerance in computers probably will continue to grow in importance. As more and more systems are computerized, people will want assurances about the reliability of these systems, and their ability to work properly even when sub-systems fail.

  10. Human factor reliability program

    International Nuclear Information System (INIS)

    Knoblochova, L.

    2017-01-01

    The human factor's reliability program was at Slovenske elektrarne, a.s. (SE) nuclear power plants. introduced as one of the components Initiatives of Excellent Performance in 2011. The initiative's goal was to increase the reliability of both people and facilities, in response to 3 major areas of improvement - Need for improvement of the results, Troubleshooting support, Supporting the achievement of the company's goals. The human agent's reliability program is in practice included: - Tools to prevent human error; - Managerial observation and coaching; - Human factor analysis; -Quick information about the event with a human agent; -Human reliability timeline and performance indicators; - Basic, periodic and extraordinary training in human factor reliability(authors)

  11. Impact of one-dose package dispensing with patient counseling on medication adherence in geriatrics suffering from chronic disorders

    Directory of Open Access Journals (Sweden)

    Narayana Goruntla

    2018-01-01

    Full Text Available Introduction: Medication nonadherence in elderly patients could result in a waste of medical expenses in a long-time span as well as deterioration of the patient's medical condition. Aim: The aim of this study is to evaluate the impact of one-dose package dispensing with patient counseling on medication adherence among elderly patients suffering from chronic disorders. Settings and Design: This is prospective, open-labeled, randomized trial carried out at dispensing pharmacy of the secondary care referral hospital, located in resource-limited settings of Anantapur District, Andhra Pradesh, India. Subjects and Methods: A total of 330 (aged ≥60 years patients were randomly assigned to one of three study groups: Group A (n = 110, no change in dosing and packing; Group B (n = 110, one-dose package dispensing; Group C (n = 110, One-dose package dispensing with patient counseling. Medication adherence levels were measured using a pill count and visual analog scale (VAS method at baseline and follow-up (after 1 month. Statistical Analysis: Descriptive statistics were used to represent the sociodemographic, clinical, and medication adherence profile of study participants. One-way ANOVA test is used to assess significant differences between three groups with a P 60 years who are on multiple medications can benefit from one-dose package dispensing and appropriate counseling. This will improve medication adherence hence better outcomes.

  12. College Cafeteria Signage Increases Water Intake but Water Position on the Soda Dispenser Encourages More Soda Consumption.

    Science.gov (United States)

    Montuclard, Astrid Linn; Park-Mroch, Jennifer; O'Shea, Amy M J; Wansink, Brian; Irvin, Jill; Laroche, Helena H

    2017-10-01

    To evaluate the effects of improved water location visibility and water dispenser position on the soda dispenser on undergraduate students' beverage choices. Two focus groups with pilot intervention surveys before and after, adding a small sign above the soda dispensers' water button for 6 weeks in a large US university's all-you-can-eat, prepaid dining hall (measured with chi-square tests and logistic and ordinal logistic regression). Focus groups included 15 students. Survey participants included 357 students before and 301 after the intervention. After the intervention, more students reported ever having drunk water with the meal (66.4% to 77.0%; P = .003) and water consumption frequency increased (P = .005). Postintervention, the odds of drinking water increased by 1.57. Preference for other drinks was the main reason for not drinking water. A total of 59% of students had ever changed their preference from water to soda. The clear indication of the water's location increased students' reported water consumption. Further investigation is needed into how a non-independent water dispenser influences students' beverage choice. Clearly labeled, independent water dispensers are recommended. Copyright © 2017 Society for Nutrition Education and Behavior. All rights reserved.

  13. Providers′ knowledge, attitude and dispensing practices of E-Pills in government dispensaries of south district in Delhi, India

    Directory of Open Access Journals (Sweden)

    Kishore Vertika

    2010-01-01

    Full Text Available Background: South Delhi is one of the well developed districts in the capital with best public health care facilities. Knowledge, attitude and dispensing practices of emergency contraceptive pills (E-pills were assessed among health care providers of government dispensaries in South Delhi. Study Design: A descriptive epidemiological study. Materials and Methods: Both medical and paramedical (n = 428 providers in 63 government health care facilities were interviewed between August to December 2007 using a semi-structured interview schedule. Results: Among the different categories of the providers, medical officers were observed to be most knowledgeable about E-pills and the pharmacists were the least. The correct prescribed dose of E-pill was known only to 32% of the providers while 49% knew about its right time of intake. Misconceptions and apprehensions for promoting its use were very much prevalent even among medical officers as majority felt that open access to E-pills would increase promiscuity. The dispensing practice of providers was found positively ( P < 0.05 correlated with their knowledge. Training resulted a significant ( P < 0.05 improvement in knowledge, attitude and dispensing practice of the providers. Knowledge and training combined together contributed 35% to the dispensing practice (R 2 = 0.35. Conclusion: Besides knowledge, behavior change communication strategies should form a part of the training curricula of health care providers that would help to improve the dispensing practice of E-pills.

  14. A Review of the Anthropometric Characteristics, Grading and Dispensation of Junior and Youth Rugby Union Players in Australia.

    Science.gov (United States)

    Patton, Declan Alexander; McIntosh, Andrew Stuart; Denny, Greg

    2016-08-01

    The grading of Australian junior and youth rugby union players has received substantial media attention in recent years. Media reports have focussed on size mismatches observed between players, especially players with Polynesian heritage, and the concerned parents who fear for the safety of their child owing to perceived mismatches. Although such concerns are well meaning, few media reports recognise the need for substantial evidence to determine the best grading system for junior and youth rugby union players. The current study reviewed relevant literature pertinent to the grading and dispensation of junior and youth rugby union players. Using primary and secondary search strategies, a total of 33 articles reporting the anthropometric characteristics of junior and youth rugby players were identified. Anthropometric data from the literature were compared with normative population data and currently used dispensation criteria. Junior and youth rugby players were found to be taller and heavier than normative population data. Current dispensation criteria, in terms of body mass, were found to vary and it is suggested that criteria be revised and standardised across rugby unions throughout Australia. Although it is acknowledged that other factors are important for grading players, anthropometric characteristics should be considered as potential dispensation criteria to supplement current age-based grading for junior and youth rugby union players. Measuring the body mass and stature of each junior player upon pre-season registration is suggested, which would provide data to establish valid dispensation criteria for the following season.

  15. Recent trends in the dispensing of 90-day-supply prescriptions at retail pharmacies: implications for improved convenience and access.

    Science.gov (United States)

    Liberman, Joshua N; Girdish, Charmaine

    2011-03-01

    Mail-service pharmacies offer consumers the convenience of prescriptions filled with a 90-day supply of medication. Unlike mail-service pharmacies, retail pharmacies traditionally dispensed maintenance medication prescriptions with a 30-day supply. However, the retail landscape changed in May 2008 with Walmart's announcement of an extension of its $4 Prescription Program to include 90-day-supply prescriptions. To evaluate recent changes in access to and use of 90-day-supply maintenance medications dispensed via retail pharmacy. As of the first quarter of 2007, the proportion of retail-dispensed maintenance medications with a 90-day supply (compared with all maintenance prescriptions dispensed) among Medicare Part D plans, self-insured employers, and private health plans was 5.1%, 5.1%, and 5.0%, respectively. As of December 2009, this ratio had risen to 8.0% for Medicare plans and 8.1% for commercial health plans; the ratio among employers had risen more modestly to 6.1%. Of particular interest and importance, the proportion increased similarly for brand and for generic medications. There has been substantial growth in 90-day prescriptions dispensed via retail pharmacy, a trend that is likely to continue as more insurance providers adopt compatible benefit designs. It is important to continue monitoring these trends and to identify opportunities to rigorously evaluate their impact on medication adherence and healthcare costs.

  16. Development of Hollow Cathode of High Power Middle Pressure Arcjet

    National Research Council Canada - National Science Library

    Vaulin, Eujeni

    1995-01-01

    ...: Determine integral performances of arcjet devices in nitrogen, ammonia, and their mixtures using hollow cathode devices at low and high current levels, perform short term tests (up to 50 hours...

  17. Ultraviolet Generation by Atmospheric Micro-Hollow Cathode Discharges

    National Research Council Canada - National Science Library

    Cooper, J

    2004-01-01

    Report developed under STTR contract for topic AFO3TOl9. This report documents the program objectives, work performed, results obtained, and future plans for a program to develop micro-hollow cathode discharge (MHCD...

  18. Cathodes for Solid Oxide Fuel Cells Operating at Low Temperatures

    DEFF Research Database (Denmark)

    Samson, Alfred Junio

    . High performance cathodes were obtained from strontium-doped lanthanum cobaltite (LSC) infiltrated - Ce0.9Gd0.1O1.95 (CGO) ionic conducting backbone. Systematic tuning of the CGO and LSC firing temperatures and LSC loading resulted in a cathode with low polarization resistance, Rp = 0.044 cm2 at 600......This dissertation focuses on the development of nanostructured cathodes for solid oxide fuel cells (SOFCs) and their performance at low operating temperatures. Cathodes were mainly fabricated by the infiltration method, whereby electrocatalysts are introduced onto porous, ionic conducting backbones...... with increasing LSC firing temperature, highlighting the importance of materials compability over higher ionic conductivity. The potential of Ca3Co4O9+delta as an electrocatalyst for SOFCs has also been explored and encouraging results were found i.e., Rp = 0.64 cm2 for a Ca3Co4O9+delta/CGO 50 vol % composite...

  19. Method of manufacture of a cathode ray tube

    International Nuclear Information System (INIS)

    1976-01-01

    This invention reveals the method of manufacturing a cathode ray tube with an electrode system for the excitation of at least two electron beams with special attention given to mounting the electrodes accurately

  20. The cathode material for a plasma-arc heater

    Science.gov (United States)

    Yelyutin, A. V.; Berlin, I. K.; Averyanov, V. V.; Kadyshevskii, V. S.; Savchenko, A. A.; Putintseva, R. G.

    1983-11-01

    The cathode of a plasma arc heater experiences a large thermal load. The temperature of its working surface, which is in contact with the plasma, reaches high values, as a result of which the electrode material is subject to erosion. Refractory metals are usually employed for the cathode material, but because of the severe erosion do not usually have a long working life. The most important electrophysical characteristic of the electrode is the electron work function. The use of materials with a low electron work function allows a decrease in the heat flow to the cathode, and this leads to an increase in its erosion resistance and working life. The electroerosion of certain materials employed for the cathode in an electric arc plasma generator in the process of reduction smelting of refractory metals was studied.

  1. Characteristics of uranium oxide cathode for neutron streak camera

    International Nuclear Information System (INIS)

    Niki, H.; Itoga, K.; Yamanaka, M.; Yamanaka, T.; Yamanaka, C.

    1986-01-01

    In laser fusion research, time-resolved neutron measurements require 20ps resolution in order to obtain the time history of the D-T burn. Uranium oxide was expected to be a sensitive material as a cathode of a neutron streak camera because of its large fission cross section. The authors report their measurements of some characteristics of the uranium oxide cathode connected to a conventional streak tube. 14 MeV neutron signal were observed as the bright spots on a TV monitor using a focus mode opration. Detection efficiency was ∼ 1 x 10 -6 for 1 μm thick cathode. Each signal consisted of more than several tens of components, which were corresponding to the secondary electrons dragged out from the cathode by a fission fragment. Time resolution is thought to be limited mainly by the transit time spread of the secondary electrons. 14ps resolution was obtained by a streak mode operation for a single fission event

  2. Lithium secondary batteries: Role of polymer cathode morphology

    Science.gov (United States)

    Naoi, Katsuhiko; Osaka, Tetsuya; Owens, Boone B.

    1988-06-01

    Electrically conducting polymers have been utilized both as the cathode and as the electrolyte element of Li secondary cells. Polymer cathodes were limited in their suitability for batteries because of the low energy content associated with low levels of doping and the inclusion of complex ionic species in the cathode. Recent studies have indicated that doping levels up to 100 percent can be achieved in polyanilene. High doping levels in combination with controlled morphologies have been found to improve the energy and rate capabilities of polymer cathodes. A morphology-modifying technique was utilized to enhance the charge/discharge characteristics of Li/liquid electrolyte polypyrrole cells. The polymer is electropolymerized in a preferred orientation morphology when the substrate is first precoated with an insulating film of nitrile butadiene rubber (NBR). Modification of the kinetic behavior of the electrode results from variations in the chemical composition of the NBR.

  3. Micro-cathode Arc Thruster PhoneSat Experiment

    Data.gov (United States)

    National Aeronautics and Space Administration — The Micro-cathode Arc Thruster Phonesat Experiment  was a joint project between George Washington University and NASA Ames Research Center that successfully...

  4. Measuring and correcting aberrations of a cathode objective lens

    International Nuclear Information System (INIS)

    Tromp, R.M.

    2011-01-01

    In this paper I discuss several theoretical and practical aspects related to measuring and correcting the chromatic and spherical aberrations of a cathode objective lens as used in Low Energy Electron Microscopy (LEEM) and Photo Electron Emission Microscopy (PEEM) experiments. Special attention is paid to the various components of the cathode objective lens as they contribute to chromatic and spherical aberrations, and affect practical methods for aberration correction. This analysis has enabled us to correct a LEEM instrument for the spherical and chromatic aberrations of the objective lens. -- Research highlights: → Presents a comprehensive theory of the relation between chromatic aberration and lens current in a cathode objective lens. → Presents practical methods for measuring both spherical and chromatic aberrations of a cathode objective lens. → Presents measurements of these aberrations in good agreement with theory. → Presents practical methods for measuring and correcting these aberrations with an electron mirror.

  5. Lithium sulfur batteries and electrolytes and sulfur cathodes thereof

    Science.gov (United States)

    Visco, Steven J.; Goncharenko, Nikolay; Nimon, Vitaliy; Petrov, Alexei; Nimon, Yevgeniy S.; De Jonghe, Lutgard C.; Katz, Bruce D.; Loginova, Valentina

    2017-05-23

    Lithium sulfur battery cells that use water as an electrolyte solvent provide significant cost reductions. Electrolytes for the battery cells may include water solvent for maintaining electroactive sulfur species in solution during cell discharge and a sufficient amount of a cycle life-enhancing compound that facilitates charging at the cathode. The combination of these two components enhances one or more of the following cell attributes: energy density, power density and cycle life. For instance, in applications where cost per Watt-Hour (Wh) is paramount, such as grid storage and traction applications, the use of an aqueous electrolyte in combination with inexpensive sulfur as the cathode active material can be a key enabler for the utility and automotive industries, for example, providing a cost effective and compact solution for load leveling, electric vehicles and renewable energy storage. Sulfur cathodes, and methods of fabricating lithium sulfur cells, in particular for loading lithium sulfide into the cathode structures, provide further advantages.

  6. Verification of high efficient broad beam cold cathode ion source

    Energy Technology Data Exchange (ETDEWEB)

    Abdel Reheem, A. M., E-mail: amreheem2009@yahoo.com [Accelerators and Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.N.13759, Cairo (Egypt); Radiation Physics Department, National Center for Radiation Research and Technology (NCRRT), Atomic Energy Authority (AEA), Cairo (Egypt); Ahmed, M. M. [Physics Department, Faculty of Science, Helwan University, Cairo (Egypt); Abdelhamid, M. M.; Ashour, A. H. [Radiation Physics Department, National Center for Radiation Research and Technology (NCRRT), Atomic Energy Authority (AEA), Cairo (Egypt)

    2016-08-15

    An improved form of cold cathode ion source has been designed and constructed. It consists of stainless steel hollow cylinder anode and stainless steel cathode disc, which are separated by a Teflon flange. The electrical discharge and output characteristics have been measured at different pressures using argon, nitrogen, and oxygen gases. The ion exit aperture shape and optimum distance between ion collector plate and cathode disc are studied. The stable discharge current and maximum output ion beam current have been obtained using grid exit aperture. It was found that the optimum distance between ion collector plate and ion exit aperture is equal to 6.25 cm. The cold cathode ion source is used to deposit aluminum coating layer on AZ31 magnesium alloy using argon ion beam current which equals 600 μA. Scanning electron microscope and X-ray diffraction techniques used for characterizing samples before and after aluminum deposition.

  7. TPC cathode read-out with C-pads

    International Nuclear Information System (INIS)

    Janik, R.; Pikna, M.; Sitar, B.; Strmen, P.; Szarka, I.

    2009-01-01

    A Time Projection Chamber with 'C' like shaped cathode pads was built and tested. It offers a low gas gain operation, a good pulse shape and a lightweight construction. The Pad Response Function (PRF), the cathode to anode pulse height ratios and the pad pulse shapes of the C-pad structure were measured and compared with planar cathode structures in two different wire geometries. The cathode to anode signal ratio was improved from between 0.2 and 0.4 up to 0.7. The PRF was considerably improved, it has a Gaussian shape and is narrower than in the case of the planar pads. The pulse shape from the C-pad read-out is similar to the pulse shape from a detector with a cylindrical shape of electrodes. A method for aluminum pad mass production based on a precise cold forging was developed and tested.

  8. The Properties of Normal Conducting Cathodes in FZD Superconducting Gun

    CERN Document Server

    Xiang, R; Buettig, H; Janssen, D; Justus, M; Lehnert, U; Michel, P; Murcek, P; Schamlott, A; Schneider, Ch; Schurig, R; Staufenbiel, F; Teichert, J

    2009-01-01

    The superconducting radio frequency photoinjector (SRF photoinjector) is one of the latest applications of SC technology in the accelerator field. Since superconducting cathodes with high QE are not available up to now, normal conducting cathode material is the main choice for the SRF photoinjectors. However, the compatibility between the cathode and the cavity is one of the challenges for this concept. The SRF gun with Cs2Te cathode has been successfully operated under the collaboration of BESSY, DESY, FZD, and MBI. In this paper, some experience gained in the gun commissioning will be concluded. The results of the properties of Cs2Te photocathode in the cavity will be presented, such as the Q.E., the life time, the dark current and the thermal emittance.

  9. Macroparticle generation in DC arc discharge from a WC cathode

    Science.gov (United States)

    Zhirkov, Igor; Polcik, Peter; Kolozsvári, Szilard; Rosen, Johanna

    2017-03-01

    We have studied macroparticle generation from a tungsten carbide cathode used in a dc vacuum arc discharge. Despite a relatively high decomposition/melting point (˜3100 K), there is an intensive generation of visible particles with sizes in the range 20-35 μm. Visual observations during the discharge and scanning electron microscopy of the cathode surface and of collected macroparticles indicate a new mechanism for particle formation and acceleration. Based on the W-C phase diagram, there is an intensive sublimation of carbon from the melt resulting from the cathode spot. The sublimation supports the formation of a sphere, which is accelerated upon an explosion initiated by Joule heating at the critical contact area between the sphere and the cathode body. The explosive nature of the particle acceleration is confirmed by surface features resembling the remains of a splash on the droplet surface.

  10. Lipon coatings for high voltage and high temperature Li-ion battery cathodes

    Energy Technology Data Exchange (ETDEWEB)

    Dudney, Nancy J.; Liang, Chengdu; Nanda, Jagjit; Veith, Gabriel M.; Kim, Yoongu; Martha, Surendra Kumar

    2017-12-05

    A lithium ion battery includes an anode and a cathode. The cathode includes a lithium, manganese, nickel, and oxygen containing compound. An electrolyte is disposed between the anode and the cathode. A protective layer is deposited between the cathode and the electrolyte. The protective layer includes pure lithium phosphorus oxynitride and variations that include metal dopants such as Fe, Ti, Ni, V, Cr, Cu, and Co. A method for making a cathode and a method for operating a battery are also disclosed.

  11. Cathodes for lithium-air battery cells with acid electrolytes

    Science.gov (United States)

    Xing, Yangchuan; Huang, Kan; Li, Yunfeng

    2016-07-19

    In various embodiments, the present disclosure provides a layered metal-air cathode for a metal-air battery. Generally, the layered metal-air cathode comprises an active catalyst layer, a transition layer bonded to the active catalyst layer, and a backing layer bonded to the transition layer such that the transition layer is disposed between the active catalyst layer and the backing layer.

  12. High-performance lanthanum-ferrite-based cathode for SOFC

    DEFF Research Database (Denmark)

    Wang, W.G.; Mogensen, Mogens Bjerg

    2005-01-01

    with LSCF/CGO on YSZ, the Rs was the same as that of our best LSM samples, which indicates good adhesion between LSCF/CGO cathode and YSZ electrolyte. Aging experiment at 800 'C for the cathode of LSCF/CGO on YSZ electrolyte shows a degradation rate of 5 x 10(-4) Omega CM2/h in R-p, while the R-s has...

  13. Development of extruded resistive plastic tubes for proportional chamber cathodes

    International Nuclear Information System (INIS)

    Kondo, K.

    1982-01-01

    Carbon mixed plastic tubes with resistivity of 10 3 approx. 10 4 Ωcm have been molded with an extrusion method and used for the d.c. cathode of a proportional counter and a multi-wire proportional chamber. The signal by gas multiplication was picked up from a strip r.f. cathode set outside the tube. The characteristics of the counter in the proportional and limited streamer modes have been studied

  14. Developments in cathodic protection. Ontwikkelingen in de kathodische bescherming

    Energy Technology Data Exchange (ETDEWEB)

    Van Bruchem, H. (VEG-Gasinstituut NV, Apeldoorn (Netherlands))

    1990-07-01

    Developments in cathodic protection of underground steel pipelines used for the transport of natural gas in the Netherlands are outlined. Besides criteria like applied negative potential in relation to ohmic resistances of soil, overprotection and the influence of stray currents, for instance in the vicinity of railroad tracks, are discussed. Control measurements of cathodic protection are described; a new method, wave form analysis, is outlined. 5 figs., 4 refs., 5 ills.

  15. Phenomenological model of an electron flow with a virtual cathode

    International Nuclear Information System (INIS)

    Koronovskij, A.A.; Khramov, A.E.; Anfinogenov, V.G.

    1999-01-01

    A phenomenological model of electron flow with a virtual cathode in diode space, which is a modification of cellular automation, is suggested. The type of models, called cellular conveyer, permits making allowance for distribution and delay in a beam with a virtual cathode. A good agreement between results of numerical study of electron flow dynamics and results obtained using the phenomenological model described has been achieved [ru

  16. Chromium (V) compounds as cathode material in electrochemical power sources

    Science.gov (United States)

    Delnick, F.M.; Guidotti, R.A.; McCarthy, D.K.

    A cathode for use in a thermal battery, comprising a chromium (V) compound. The preferred materials for this use are Ca/sub 5/(CrO/sub 4/)/sub 3/Cl, Ca/sub 5/(CrO/sub 4/)OH, and Cr/sub 2/O/sub 5/. The chromium (V) compound can be employed as a cathode material in ambient temperature batteries when blended with a suitably conductive filler, preferably carbon black.

  17. Fabrication and description of a cold cathode electron gun

    International Nuclear Information System (INIS)

    Sari, A.H.; Ghorannevis, M.; Hantehzadeh, M.R.; Yousefi, M.R.

    2003-01-01

    In this study the structure and schematic configuration of a cold cathode electron gun has been shown, which use obstructed discharge for electron producing. This type of discharge and mechanism of secondary electron emission by ions and fast neutral interaction have been described. The experiment starts in pressure of 1*10 -3 torr, in existence of helium gas. A negative DC voltage apply to a concave cathode up to -20 k V which determine electron energy

  18. High-Current Cold Cathode Employing Diamond and Related Materials

    Energy Technology Data Exchange (ETDEWEB)

    Hirshfield, Jay L. [Omega-P, Inc., New Haven, CT (United States)

    2014-10-22

    The essence of this project was for diamond films to be deposited on cold cathodes to improve their emission properties. Films with varying morphology, composition, and size of the crystals were deposited and the emission properties of the cathodes that utilize such films were studied. The prototype cathodes fabricated by the methods developed during Phase I were tested and evaluated in an actual high-power RF device during Phase II. These high-power tests used the novel active RF pulse compression system and the X-band magnicon test facility at US Naval Research Laboratory. In earlier tests, plasma switches were employed, while tests under this project utilized electron-beam switching. The intense electron beams required in the switches were supplied from cold cathodes embodying diamond films with varying morphology, including uncoated molybdenum cathodes in the preliminary tests. Tests with uncoated molybdenum cathodes produced compressed X-band RF pulses with a peak power of 91 MW, and a maximum power gain of 16.5:1. Tests were also carried out with switches employing diamond coated cathodes. The pulse compressor was based on use of switches employing electron beam triggering to effect mode conversion. In experimental tests, the compressor produced 165 MW in a ~ 20 ns pulse at ~18× power gain and ~ 140 MW at ~ 16× power gain in a 16 ns pulse with a ~ 7 ns flat-top. In these tests, molybdenum blade cathodes with thin diamond coatings demonstrated good reproducible emission uniformity with a 100 kV, 100 ns high voltage pulse. The new compressor does not have the limitations of earlier types of active pulse compressors and can operate at significantly higher electric fields without breakdown.

  19. High precision straw tube chamber with cathode readout

    International Nuclear Information System (INIS)

    Bychkov, V.N.; Golutvin, I.A.; Ershov, Yu.V.

    1992-01-01

    The high precision straw chamber with cathode readout was constructed and investigated. The 10 mm straws were made of aluminized mylar strip with transparent longitudinal window. The X coordinate information has been taken from the cathode strips as induced charges and investigated via centroid method. The spatial resolution σ=120 μm has been obtained with signal/noise ratio about 60. The possible ways for improving the signal/noise ratio have been described. 7 refs.; 8 figs

  20. A high precision straw tube chamber with cathode readout

    International Nuclear Information System (INIS)

    Bychkov, V.N.; Golutvin, I.A.; Ershov, Yu.V.; Zubarev, E.V.; Ivanov, A.B.; Lysiakov, V.N.; Makhankov, A.V.; Movchan, S.A.; Peshekhonov, V.D.; Preda, T.

    1993-01-01

    The high precision straw chamber with cathode readout was constructed and investigated. The 10 mm diameter straws were made of aluminized Mylar with transparent longitudinal window. The X-coordinate information has been taken from cathode strips as induced charges and investigated with the centroid method. The spatial resolution σ x =103 μm was obtained at a signal-to-noise ratio of about 70. The possible ways to improve the signal-to-noise ratio are discussed. (orig.)

  1. Cathodic reduction of benzil in acetone and in dichloromethane

    Energy Technology Data Exchange (ETDEWEB)

    Quintanilla, Gloria [Departamento de Quimica Organica, Universidad de Alcala, 28871 Alcala de Henares, Madrid (Spain)], E-mail: gloria.quintanilla@uah.es; Liebeck, Miriam; Bengtsson, Carina; Arnold, Lena; Barba, Fructuoso [Departamento de Quimica Organica, Universidad de Alcala, 28871 Alcala de Henares, Madrid (Spain)

    2008-02-15

    The cathodic reduction of benzil has been carried out at a controlled potential on a mercury cathode in two different SSE (solvent-supporting-electrolyte) conditions: (a) acetone/lithium perchlorate in absence of electrophile where 2,3-diphenyl-5-methyl-furan and 1,2-diphenyl-2-hydroxy-1,4-pentanedione were obtained as main products and (b) dichloromethane/tetrabuthylammonium chloride with the addition of oxalyl chloride as electrophile, where a fast electron transfer took place.

  2. AB/sub 5/-catalyzed hydrogen evolution cathodes

    Energy Technology Data Exchange (ETDEWEB)

    Hall, D E; Sawada, T; Shepard, V R; Tsujikawa, Y

    1984-01-01

    The AB/sub 5/ metal compounds are highly efficient hydrogen evolution electrocatalysts in alkaline electrolyte. Three types of AB/sub 5/-catalyzed cathode structures were made, using the hydride-forming AB/sub 5/ compounds in particulate form. Plastic-bonded cathodes containing >90 w/o AB/sub 5/ (finished-weight basis) were the most efficient, giving hydrogen evolution overpotentials (/eta/ /SUB H2/ ) of about 0.05 V at 200 mA cm/sup -2/. However, they tended to swell and shed material during electrolysis. Pressed, sintered cathodes containing 40-70 w/o catalyst in a nickel binder gave /eta/ /SUB H2/ about0.08 V; catalyst retention was excellent. Porous, sintered cathode coatings were made with 30-70 w/o AB/sub 5/ catalyst loadings. Their overpotentials were similar to those of the pressed, sintered cathodes. However, at catalyst loadings below about 40 w/o, high overpotentials characteristic of the nickel binder were observed. The structural and electrochemical properties of the three AB/sub 5/-catalyzed cathodes are discussed.

  3. Cathode erosion in high-current high-pressure arc

    CERN Document Server

    Nemchinsky, V A

    2003-01-01

    Cathode erosion rate was experimentally investigated for two types of arcs: one with tungsten cathode in nitrogen atmosphere and one with hafnium cathode in oxygen atmosphere. Conditions were typical for plasma arc cutting systems: gas pressure from 2 to 5 atm, arc current from 200 to 400 A, gas flow rate from 50 to 130 litre min sup - sup 1. It was found that the actual cathode evaporation rate G is much lower than G sub 0 , the evaporation rate that follows from the Hertz-Knudsen formula: G = nu G sub 0. The difference is because some of the evaporated particles return back to the cathode. For conditions of our experiments, the factor nu could be as low as 0.01. It was shown experimentally that nu depends strongly on the gas flow pattern close to the cathode. In particular, swirling the gas increases nu many times. To explain the influence of gas swirling, model calculations of gas flows were performed. These calculations revealed difference between swirling and non-swirling flows: swirling the gas enhances...

  4. Impact of cathode evaporation on a free-burning arc

    International Nuclear Information System (INIS)

    Etemadi, K.

    1990-01-01

    In the center of a free-burning, high intensity argon arc at atmospheric pressure, a highly ionized vapor beam of copper has been generated by a continuous feeding of a thin (0.5 and 1 mm diameter) copper wire to the hot surface region of the cathode in the vicinity of the plasma attachment. The copper vapor is carried into the plasma column between the electrodes by the self-magnetic induced plasma flow caused by the conical shape of the cathode. In order to study the vapor beam, the arc is modeled at atmospheric pressure, with a current of 150 A, a gap spacing of 1 cm, a cathode tip of 60 degrees and a copper vapor flow of 1 mg/s. The temperature, mass flow, current flow and Cu concentration are calculated for the entire plasma region. The intensity distribution of CuI spectral line at 5218.2 angstrom is also recorded by emission spectroscopy and compared with the calculated values. The copper vapor in the cathode region has velocities of 210 m/s with a mass concentration of above 90% within 0.5 mm from the arc axis. The vapor passes from the cathode toward the anode with a slight diffusion in the argon plasma. Higher temperatures and current densities in the core of the arc, caused by the cathode evaporation, are calculated

  5. Cathodic protection for the bottoms of above ground storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    Mohr, John P. [Tyco Adhesives, Norwood, MA (United States)

    2004-07-01

    Impressed Current Cathodic Protection has been used for many years to protect the external bottoms of above ground storage tanks. The use of a vertical deep ground bed often treated several bare steel tank bottoms by broadcasting current over a wide area. Environmental concerns and, in some countries, government regulations, have introduced the use of dielectric secondary containment liners. The dielectric liner does not allow the protective cathodic protection current to pass and causes corrosion to continue on the newly placed tank bottom. In existing tank bottoms where inadequate protection has been provided, leaks can develop. In one method of remediation, an old bottom is covered with sand and a double bottom is welded above the leaking bottom. The new bottom is welded very close to the old bottom, thus shielding the traditional cathodic protection from protecting the new bottom. These double bottoms often employ the use of dielectric liner as well. Both the liner and the double bottom often minimize the distance from the external tank bottom. The minimized space between the liner, or double bottom, and the bottom to be protected places a challenge in providing current distribution in cathodic protection systems. This study examines the practical concerns for application of impressed current cathodic protection and the types of anode materials used in these specific applications. One unique approach for an economical treatment using a conductive polymer cathodic protection method is presented. (author)

  6. Testing Iodine as a New Fuel for Cathodes

    Science.gov (United States)

    Glad, Harley; Branam, Richard; Rogers, Jim; Warren, Matthew; Burleson, Connor; Siy, Grace

    2017-11-01

    The objective of this research is to demonstrate the viability of using iodine as an alternative space propulsion propellant. The demonstration requires the testing of a cathode with xenon and then the desired element iodine. Currently, cathodes run on noble gases such as xenon which must be stored in high pressure canisters and is very expensive. These shortcomings have led to researching possible substitutes. Iodine was decided as a suitable candidate because it's cheaper, can be stored as a solid, and has similar mass properties as xenon. In this research, cathodes will be placed in a vacuum chamber and operated on both gases to observe their performance, allowing us to gain a better understanding of iodine's behavior. Several planned projects depend on the knowledge gained from this project, such as larger scaled tests and iodine fed hall thrusters. The tasks of this project included protecting the stainless-steel vacuum chamber by gold plating and Teflon® coating, building a stand to hold the cathode, creating an anode resistant to iodine, and testing the cathode once setup was complete. The successful operation of the cathode was demonstrated. However, the experimental setup proved ineffective at controlling the iodine flow. Current efforts are focused on this problem. REU Site: Fluid Mechanics with Analysis using Computations and Experiments NSF Grant EEC 1659710.

  7. An adjustable electron achromat for cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M., E-mail: rtromp@us.ibm.com [IBM T.J. Watson Research Center, 1101 Kitchawan Road, Yorktown Heights, NY 10598 (United States); Leiden Institute of Physics, Kamerlingh Onnes Laboratory, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-12-15

    Chromatic aberration correction in light optics began with the invention of a two-color-corrected achromatic crown/flint lens doublet by Chester Moore Hall in 1730. Such color correction is necessary because any single glass shows dispersion (i.e. its index of refraction changes with wavelength), which can be counteracted by combining different glasses with different dispersions. In cathode lens microscopes (such as Photo Electron Emission Microscopy – PEEM) we encounter a similar situation, where the chromatic aberration coefficient of the cathode lens shows strong dispersion, i.e. depends (non-linearly) on the energy with which the electrons leave the sample. Here I show how a cathode lens in combination with an electron mirror can be configured as an adjustable electron achromat. The lens/mirror combination can be corrected at two electron energies by balancing the settings of the electron mirror against the settings of the cathode lens. The achromat can be adjusted to deliver optimum performance, depending on the requirements of a specific experiment. Going beyond the achromat, an apochromat would improve resolution and transmission by a very significant margin. I discuss the requirements and outlook for such a system, which for now remains a wish waiting for fulfilment. - Highlights: • The properties of cathode objective lens plus electron mirror are discussed. • In analogy with light-optical achromats, cathode lens plus mirror can be configured as an electron achromat. • Unlike light optics, the electron achromat can be adjusted to best fulfill experimental requirements.

  8. Study on pulsed current cathodic protection in a simulated system

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Milin; Li, Helin [Xi' an Jiao Tong Universitiy (China)]|[Tubular Goods Research Center of China National Petroleum Corp. (China); Qiu, Yubing; Guo, Xingpeng [Hua Zhong University of Science and Techonology (China)

    2004-07-01

    The pulsed current cathodic protection (PCCP) is a new cathodic protection (CP) technology and shows more advantages over the conventional DC cathodic protection (DCCP) in oil well casing system. However, little information about PCCP is reported. In this research, a simulated CP system was set up in a pool of 3.5 m x 2.0 m x 3.0 m size, in which the effects of the square wave pulsed current (SWPC) parameters (amplitude: IA, frequency: f, duty cycle: P), auxiliary anode distance (d) and media conductivity ({mu}) on the cathodic potential (E) distribution were studied, and the protection effects of PCCP and DCCP were compared. The results show that with increase of the square wave parameters (IA, f, P), the E distribution becomes more negative and the effects of each current parameter are relate closely to the cathode polarizing state. Only with suitable square wave parameters can the whole cathode be effectively protected. With increase of d and {mu}, the E distribution becomes more uniform. Compared with DCCP system, PCCP system has much more uniform E distribution, costs less average current, and gains much better protection effects. Further, the mechanism of PCCP was analyzed. (authors)

  9. Pr0.6Sr0.4CoO3-δ electrocatalyst for solid oxide fuel cell cathode introduced via infiltration

    International Nuclear Information System (INIS)

    Lee, Shiwoo; Miller, Nicholas; Staruch, Margo; Gerdes, Kirk; Jain, Menka; Manivannan, Ayyakkannu

    2011-01-01

    Highlights: → High electrocatalytic activity of Sr-doped PrCoO 3 for oxygen reduction reaction has been demonstrated. → 35-38% of power density enhancement has been achieved for a commercial cell by introducing Sr-doped PrCoO 3 via infiltration. → Fuel cells modified with nano-sized electrocatalyst have shown relatively stable performance for 200 h. → Reliable performance comparison has been realized by utilizing a parallel cell testing system. - Abstract: Effects of infiltrated Pr 0.6 Sr 0.4 CoO 3-δ (PSCo) electrocatalyst on SOFC cathode performance have been studied. Nano-sized particulate catalysts, deposited on surfaces of a composite cathode of Sm 2 O 3 doped CeO 2 (SDC) and La 1-x Sr x Co 1-y Fe y O 3-δ (LSCF), are assumed to effectively widen active sites, or triple phase boundaries, for the oxygen reduction reaction. Area specific resistance of commercially available cells has been decreased by 36-40% with the addition of 23 wt% PSCo electrocatalyst on cathode. Analysis of the impedance spectra demonstrates that PSCo electrocatalyst plays a significant role in dissociation of oxygen molecules and adsorption of oxygen atoms into the cathode. A total of 200 h operation of the cells demonstrated that catalytic activity of PSCo has not been significantly degraded. Simultaneous operations of multiple cells using a parallel-cell testing system have made it possible to compare the performance of several cells with high reliability.

  10. Effect of holed reflector on acoustic radiation force in noncontact ultrasonic dispensing of small droplets

    Science.gov (United States)

    Tanaka, Hiroki; Wada, Yuji; Mizuno, Yosuke; Nakamura, Kentaro

    2016-06-01

    We investigated the fundamental aspects of droplet dispensing, which is an important procedure in the noncontact ultrasonic manipulation of droplets in air. A holed reflector was used to dispense a droplet from a 27.4 kHz standing-wave acoustic field to a well. First, the relationship between the hole diameter of the reflector and the acoustic radiation force acting on a levitated droplet was clarified by calculating the acoustic impedance of the point just above the hole. When the hole diameter was half of (or equal to) the acoustic wavelength λ, the acoustic radiation force was ∼80% (or 50%) of that without a hole. The maximal diameters of droplets levitated above the holes through flat and half-cylindrical reflectors were then experimentally investigated. For instance, with the half-cylindrical reflector, the maximal diameter was 5.0 mm for a hole diameter of 6.0 mm, and droplets were levitatable up to a hole diameter of 12 mm (∼λ).

  11. Molecular Epidemiology of a Pseudomonas aeruginosa Hospital Outbreak Driven by a Contaminated Disinfectant-Soap Dispenser

    Science.gov (United States)

    Lanini, Simone; D'Arezzo, Silvia; Puro, Vincenzo; Martini, Lorena; Imperi, Francesco; Piselli, Pierluca; Montanaro, Marco; Paoletti, Simonetta; Visca, Paolo; Ippolito, Giuseppe

    2011-01-01

    Background and Objective Pseudomonas aeruginosa infection represents a main cause of morbidity and mortality among immunocompromised patients. This study describes a fatal epidemic of P. aeruginosa that occurred in a hematology unit in Italy. Methods Retrospective cohort study, prospective surveillance, auditing, extensive testing on healthcare workers and environmental investigation were performed to define the dynamics and potential causes of transmission. RAPD, macrorestriction analyses and sequence typing were used to define relationships between P. aeruginosa isolates. Results Eighteen cases of infection were identified in the different phases of the investigation. Of these, five constitute a significant molecular cluster of infection. A P. aeruginosa strain with the same genetic fingerprint and sequence type (ST175) as clinical isolates strain was also isolated from a heavily contaminated triclosan soap dispenser. Discussion and Conclusions Our results are consistent with the hypothesis that patients became indirectly infected, e.g., during central venous catheter handling through contaminated items, and that the triclosan soap dispenser acted as a common continuous source of P. aeruginosa infection. Since P. aeruginosa is intrinsically unsusceptible to triclosan, the use of triclosan-based disinfectant formulations should be avoided in those healthcare settings hosting patients at high risk of P. aeruginosa infection. PMID:21359222

  12. Prescription Drug Monitoring Programs and Pharmacist Orientation Toward Dispensing Controlled Substances.

    Science.gov (United States)

    Fendrich, Michael; Bryan, Janelle K; Hooyer, Katinka

    2018-01-03

    We sought to understand how pharmacists viewed and used a newly implemented prescription drug monitoring program (PDMP). We also sought to understand pharmacist orientation toward dispensing of controlled substances and the people who obtain them. We conducted three mini focus groups. The focus group findings were used to inform the design of a structured survey. We emailed a survey to 160 pharmacists who were employed in one statewide community chain store; we obtained 48 survey responses. Focus groups findings suggested that, in relation to the dispensing of scheduled prescription medication, pharmacists were either "healthcare" oriented, "law-enforcement" oriented, or an orientation that combined these two perspectives. Surveys suggested that pharmacists found PDMPs easy to use and that they used them frequently - often to contact physicians directly. Surveys suggested that pharmacists were typically either "healthcare" oriented or "mixed" (combined perspectives). Pharmacist orientation was associated with the frequency with which they counseled patients about medication risk and the frequency with which they used the PDMP as the basis for contacting prescribers. Ongoing tracking of pharmacists' use of PDMPs is important both at the implementation stage and as PDMPs develop over time. The orientation construct developed here is useful in understanding pharmacist behavior and attitudes towards patients potentially at risk for misuse of controlled substance medications. Further research on this construct could shed light on barriers and incentives for pharmacist PDMP participation and use and provide guidance for pharmacist training, ultimately enhancing patient care.

  13. Vital and dispensable roles of Plasmodium multidrug resistance transporters during blood- and mosquito-stage development.

    Science.gov (United States)

    Rijpma, Sanna R; van der Velden, Maarten; Annoura, Takeshi; Matz, Joachim M; Kenthirapalan, Sanketha; Kooij, Taco W A; Matuschewski, Kai; van Gemert, Geert-Jan; van de Vegte-Bolmer, Marga; Siebelink-Stoter, Rianne; Graumans, Wouter; Ramesar, Jai; Klop, Onny; Russel, Frans G M; Sauerwein, Robert W; Janse, Chris J; Franke-Fayard, Blandine M; Koenderink, Jan B

    2016-07-01

    Multidrug resistance (MDR) proteins belong to the B subfamily of the ATP Binding Cassette (ABC) transporters, which export a wide range of compounds including pharmaceuticals. In this study, we used reverse genetics to study the role of all seven Plasmodium MDR proteins during the life cycle of malaria parasites. Four P. berghei genes (encoding MDR1, 4, 6 and 7) were refractory to deletion, indicating a vital role during blood stage multiplication and validating them as potential targets for antimalarial drugs. Mutants lacking expression of MDR2, MDR3 and MDR5 were generated in both P. berghei and P. falciparum, indicating a dispensable role for blood stage development. Whereas P. berghei mutants lacking MDR3 and MDR5 had a reduced blood stage multiplication in vivo, blood stage growth of P. falciparum mutants in vitro was not significantly different. Oocyst maturation and sporozoite formation in Plasmodium mutants lacking MDR2 or MDR5 was reduced. Sporozoites of these P. berghei mutants were capable of infecting mice and life cycle completion, indicating the absence of vital roles during liver stage development. Our results demonstrate vital and dispensable roles of MDR proteins during blood stages and an important function in sporogony for MDR2 and MDR5 in both Plasmodium species. © 2016 John Wiley & Sons Ltd.

  14. Barriers, motivators and enablers for dispensing multifocal contact lenses in Mumbai, India.

    Science.gov (United States)

    Thite, Nilesh; Shah, Ukti; Mehta, Jasmin; Jurkus, Janice

    2015-01-01

    To understand the potential barriers, motivators and enablers in dispensing multifocal contact lenses (MFCL). Two focus group discussions were conducted to design questionnaires regarding the prescribing habits for multifocal contact lenses (MFCL). Questions on potential barriers and motivators were included. The questionnaires were distributed among 133 eye care practitioners across Mumbai, India. Practitioners fitting one or less patient per month with MFCL completed the survey describing potential barriers, while those who prescribed more MFCL's per month completed the survey describing enablers and motivators. Responses from 102 practitioners were received. Most common potential barriers in prescribing MFCL were increased chair time (75%), lack of readily available trials (69%) and limitation in power range (63%). Lack of awareness among patients (90%) was the most common barrier from patients' outlook. Professional satisfaction (88%) and better business proposition (82%) were observed as main motivators while availability of the trials (84%) and correct patient selection (82%) were the major enablers. Graduate Optometrists felt dispensing MFCL did not offer a good business proposition (p=0.02). Experienced practitioners were observed to be least motivated (p=0.01) and believed that their patients found these lenses expensive (p=0.02). To enhance the MFCL practice, barriers like lack of awareness and limitations in power range must be addressed. Trial lens availability may motivate practitioners to prescribe MFCL. Further probing is required to understand lack of motivation among experienced practitioners. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  15. Performance of MSGCs with cathode readout

    International Nuclear Information System (INIS)

    Cremaldi, L.; Finocchiaro, G.; Rajagopalan, S.; Schamberger, D.

    1996-01-01

    The performance of a telescope of Micro-Strip Gas Chambers (MSGC) has been studied in a beam of minimum ionizing particles. Detectors of two different pitches have been studied. The position resolutions is obtained by reading out the cathodes and interpolating based on the amplitude of the signals. The position of the hit in the chamber is found to differ systematically from the cluster centroid position. A correction method is derived from the data and applied to improve the resolution. After correction, the spatial resolution of chambers with 200 μm pitch is found to be 42 μm, and for the 400 μm pitch detectors the resolution is 42 μm. The improved interpolation for the 400 μm pitch chamber can be understood in terms of the better signal to noise observed for the 400 μm pitch detectors. The degradation in resolution as a function of angle of track incidence is also expected to be less for the larger pitch chambers

  16. Lithium Iron Orthosilicate Cathode: Progress and Perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Jiangfeng [College; amp, Physics (CECMP), Soochow University, Suzhou 215006, PR China; Jiang, Yu [College; amp, Physics (CECMP), Soochow University, Suzhou 215006, PR China; Bi, Xuanxuan [Chemical; Li, Liang [College; amp, Physics (CECMP), Soochow University, Suzhou 215006, PR China; Lu, Jun [Chemical

    2017-07-18

    The pursuit of cathodes with a high capacity is remarkably driven by the ever increasing demand of high-energy lithium ion batteries in electronics and transportation. In this regard, polyanionic lithium iron orthosilicate (Li2FeSiO4) offers a promising opportunity because it affords a high theoretical capacity of 331 mAh g–1. However, such a high theoretical capacity of Li2FeSiO4 has frequently been compromised in practice because of the extremely low electronic and ionic conductivity. To address this issue, material engineering strategies to boost the Li storage kinetics in Li2FeSiO4 have proven indispensable. In this Perspective, we will briefly present the structural characteristics, intrinsic physicochemical properties, and electrochemical behavior of Li2FeSiO4. We particularly focus on recent materials engineering of silicates, which is implemented mainly through advanced synthetic techniques and elaborate controls. This Perspective highlights the importance of integrating theoretical analysis into experimental implementation to further advance the Li2FeSiO4 materials.

  17. MWPC with highly segmented cathode pad readout

    International Nuclear Information System (INIS)

    Debbe, R.; Fischer, J.; Lissauer, D.

    1989-01-01

    Experiments being conducted with high energy heavy ion beams at Brookhaven National Laboratory and at CERN have shown the importance of developing position sensitive detectors capable of handling events with high multiplicity in environments of high track density as will also be the case in future high luminosity colliders like SSC and RHIC. In addition, these detectors are required to have a dynamic range wide enough to detect minimum ionizing particles and heavy ions like oxygen or silicon. We present here a description of work being done on a prototype of such a detector at BNL. Results from a similar counter are also presented in this Conference. The ''pad chamber'' is a detector with a cathode area subdivided into a very large number of pixel-like elements such that a charged particle traversing the detector at normal incidence leaves an induced charge on a few localized pads. The pads are interconnected by a resistive strip, and readout amplifiers are connected to the resistive strip at appropriate, carefully determined spacings. The pattern of tracks in a multi-hit event is easily recognized, and a centroid-finding readout system allows position determination to a small fraction of the basic cell size. 5 refs., 9 figs

  18. A one-dimensional model illustrating virtual-cathode formation in a novel coaxial virtual-cathode oscillator

    International Nuclear Information System (INIS)

    Turner, Geoffrey R.

    2014-01-01

    A one-dimensional electrostatic sheet model of a coaxial geometry Virtual Cathode Oscillator (VCO) is presented. The cathode is centrally located and connects to a peripherally located plate electrode to form a resonant cavity, and is thus considered to be a novel design. Charge is modelled as concentric sheets about the cathode whose absolute position and velocity are determined as a function of time by solving the relativistic equations of motion. The model predicts the formation of a virtual cathode between the grid and plate electrodes for the case of a space-charge limited current. Setting the electron reflexing frequency (as a function of the grid potential) comparable with the cavity resonant frequency is predicted to improve the efficiency of microwave emission

  19. Air humidity and water pressure effects on the performance of air-cathode microbial fuel cell cathodes

    KAUST Repository

    Ahn, Yongtae; Zhang, Fang; Logan, Bruce E.

    2014-01-01

    To better understand how air cathode performance is affected by air humidification, microbial fuel cells were operated under different humidity conditions or water pressure conditions. Maximum power density decreased from 1130 ± 30 mW m-2 with dry

  20. Prototype of a Questionnaire and Quiz System for Supporting Increase of Health Awareness During Wait Time in Dispensing Pharmacy

    Science.gov (United States)

    Toda, Takeshi; Chen, Poa-Min; Ozaki, Shinya; Ideguchi, Naoko; Miyaki, Tomoko; Nanbu, Keiko; Ikeda, Keiko

    For quit-smoking clinic and its campaign, there was a need for pharmacists to investigate pediatric patient's parent consciousness to tobacco harm utilizing wait time in a pediatric dispensing pharmacy. In this research, we developed the questionnaire and quiz total system using the tablet for user interface, in which people can easily answer the questionnaire/quiz and quickly see the total results on the spot in order to enhance their consciousness to the tobacco harm. The system also provides their tobacco dependence level based on the questionnaire results and some advice for their health and dietary habits due to the tobacco dependence level. From a field trial with one hundred four examinees in the pediatric dispensing pharmacy, the user interface was useful compared to conventional questionnaire form. The system could enhance their consciousness to tobacco harm and make their beneficial use of waiting time in dispensing pharmacy. Some interesting suggestions for improvement and new services were also obtained.

  1. Treatment practices of households and antibiotic dispensing in medicine outlets in developing countries: The case of Ghana

    DEFF Research Database (Denmark)

    Tersbøl, Britt Pinkowski

    2018-01-01

    in households and the antibiotic dispensing practices of medicine sales outlets in Eastern region, Ghana. Method: Twice-weekly illness recall visits were made to 12 households in three rural communities over eight consecutive weeks. Detailed fieldnotes were taken and analysed using a thematic approach....... Quantitative counts of health events and treatment were also conducted. Dispensing practices were systematically observed and documented in three rural and three urban medicine outlets for analysis. Result: Fever, abdominal, and respiratory symptoms were the most common causes of ill-health in the 12...... an integral part of healthcare in the study settings and the qualitative data provides a contextual understanding of over-the-counter antibiotic acquisition and use. Inappropriate antibiotic use is apparent in the study settings. Stricter regulation of the pharmaceutical sector, training of dispensers...

  2. Reliability and safety engineering

    CERN Document Server

    Verma, Ajit Kumar; Karanki, Durga Rao

    2016-01-01

    Reliability and safety are core issues that must be addressed throughout the life cycle of engineering systems. Reliability and Safety Engineering presents an overview of the basic concepts, together with simple and practical illustrations. The authors present reliability terminology in various engineering fields, viz.,electronics engineering, software engineering, mechanical engineering, structural engineering and power systems engineering. The book describes the latest applications in the area of probabilistic safety assessment, such as technical specification optimization, risk monitoring and risk informed in-service inspection. Reliability and safety studies must, inevitably, deal with uncertainty, so the book includes uncertainty propagation methods: Monte Carlo simulation, fuzzy arithmetic, Dempster-Shafer theory and probability bounds. Reliability and Safety Engineering also highlights advances in system reliability and safety assessment including dynamic system modeling and uncertainty management. Cas...

  3. What do Australian consumers, pharmacists and prescribers think about documenting indications on prescriptions and dispensed medicines labels?: A qualitative study.

    Science.gov (United States)

    Garada, Mona; McLachlan, Andrew J; Schiff, Gordon D; Lehnbom, Elin C

    2017-11-15

    Documenting the indication on prescriptions and dispensed medicines labels is not standard practice in Australia. However, previous studies that have focused on the content and design of dispensed medicines labels, have suggested including the indication as a safety measure. The aim of this study was to investigate the perspectives of Australian consumers, pharmacists and prescribers on documenting the indication on prescriptions and dispensed medicines labels. Semi-structured interviews were conducted and mock-up of dispensed medicines labels were designed for participants. Consumers (n = 19) and pharmacists (n = 7) were recruited by convenience sample at community pharmacies in Sydney (Australia) and prescribers (n = 8), including two medical students, were recruited through snowballing. Thirty-four participants were interviewed. Most participants agreed that documenting the indication would be beneficial especially for patients who are forgetful or take multiple medications. Participants also believed it would improve consumers' medication understanding and adherence. Prescribers and pharmacists believed it could help reduce prescribing and dispensing errors by matching the drug/dosage to the correct indication. Prescribers refrained from documenting the indication to protect patients' privacy; however, most patients did not consider documenting the indication as a breach of privacy. Prescribers raised concerns about the extra time to include indications on prescriptions and best language to document indications, using plain language as opposed to medical terminology. All interviewed stakeholders identified numerous benefits of documenting the indication on prescriptions and dispensed medicines labels. Whether these potential benefits can be realized remains unknown and addressing prescribers' concern regarding the time involved in documenting the indication on prescriptions remains a challenge for vendors of electronic medication management systems.

  4. What do Australian consumers, pharmacists and prescribers think about documenting indications on prescriptions and dispensed medicines labels?: A qualitative study

    Directory of Open Access Journals (Sweden)

    Mona Garada

    2017-11-01

    Full Text Available Abstract Background Documenting the indication on prescriptions and dispensed medicines labels is not standard practice in Australia. However, previous studies that have focused on the content and design of dispensed medicines labels, have suggested including the indication as a safety measure. The aim of this study was to investigate the perspectives of Australian consumers, pharmacists and prescribers on documenting the indication on prescriptions and dispensed medicines labels. Methods Semi-structured interviews were conducted and mock-up of dispensed medicines labels were designed for participants. Consumers (n = 19 and pharmacists (n = 7 were recruited by convenience sample at community pharmacies in Sydney (Australia and prescribers (n = 8, including two medical students, were recruited through snowballing. Results Thirty-four participants were interviewed. Most participants agreed that documenting the indication would be beneficial especially for patients who are forgetful or take multiple medications. Participants also believed it would improve consumers’ medication understanding and adherence. Prescribers and pharmacists believed it could help reduce prescribing and dispensing errors by matching the drug/dosage to the correct indication. Prescribers refrained from documenting the indication to protect patients’ privacy; however, most patients did not consider documenting the indication as a breach of privacy. Prescribers raised concerns about the extra time to include indications on prescriptions and best language to document indications, using plain language as opposed to medical terminology. Conclusions All interviewed stakeholders identified numerous benefits of documenting the indication on prescriptions and dispensed medicines labels. Whether these potential benefits can be realized remains unknown and addressing prescribers’ concern regarding the time involved in documenting the indication on prescriptions

  5. Human reliability analysis

    International Nuclear Information System (INIS)

    Dougherty, E.M.; Fragola, J.R.

    1988-01-01

    The authors present a treatment of human reliability analysis incorporating an introduction to probabilistic risk assessment for nuclear power generating stations. They treat the subject according to the framework established for general systems theory. Draws upon reliability analysis, psychology, human factors engineering, and statistics, integrating elements of these fields within a systems framework. Provides a history of human reliability analysis, and includes examples of the application of the systems approach

  6. Reliability of electronic systems

    International Nuclear Information System (INIS)

    Roca, Jose L.

    2001-01-01

    Reliability techniques have been developed subsequently as a need of the diverse engineering disciplines, nevertheless they are not few those that think they have been work a lot on reliability before the same word was used in the current context. Military, space and nuclear industries were the first ones that have been involved in this topic, however not only in these environments it is that it has been carried out this small great revolution in benefit of the increase of the reliability figures of the products of those industries, but rather it has extended to the whole industry. The fact of the massive production, characteristic of the current industries, drove four decades ago, to the fall of the reliability of its products, on one hand, because the massively itself and, for other, to the recently discovered and even not stabilized industrial techniques. Industry should be changed according to those two new requirements, creating products of medium complexity and assuring an enough reliability appropriated to production costs and controls. Reliability began to be integral part of the manufactured product. Facing this philosophy, the book describes reliability techniques applied to electronics systems and provides a coherent and rigorous framework for these diverse activities providing a unifying scientific basis for the entire subject. It consists of eight chapters plus a lot of statistical tables and an extensive annotated bibliography. Chapters embrace the following topics: 1- Introduction to Reliability; 2- Basic Mathematical Concepts; 3- Catastrophic Failure Models; 4-Parametric Failure Models; 5- Systems Reliability; 6- Reliability in Design and Project; 7- Reliability Tests; 8- Software Reliability. This book is in Spanish language and has a potentially diverse audience as a text book from academic to industrial courses. (author)

  7. Operational safety reliability research

    International Nuclear Information System (INIS)

    Hall, R.E.; Boccio, J.L.

    1986-01-01

    Operating reactor events such as the TMI accident and the Salem automatic-trip failures raised the concern that during a plant's operating lifetime the reliability of systems could degrade from the design level that was considered in the licensing process. To address this concern, NRC is sponsoring the Operational Safety Reliability Research project. The objectives of this project are to identify the essential tasks of a reliability program and to evaluate the effectiveness and attributes of such a reliability program applicable to maintaining an acceptable level of safety during the operating lifetime at the plant

  8. Circuit design for reliability

    CERN Document Server

    Cao, Yu; Wirth, Gilson

    2015-01-01

    This book presents physical understanding, modeling and simulation, on-chip characterization, layout solutions, and design techniques that are effective to enhance the reliability of various circuit units.  The authors provide readers with techniques for state of the art and future technologies, ranging from technology modeling, fault detection and analysis, circuit hardening, and reliability management. Provides comprehensive review on various reliability mechanisms at sub-45nm nodes; Describes practical modeling and characterization techniques for reliability; Includes thorough presentation of robust design techniques for major VLSI design units; Promotes physical understanding with first-principle simulations.

  9. Existence of a virtual cathode close to a strongly electron emissive wall in low density plasmas

    International Nuclear Information System (INIS)

    Tierno, S. P.; Donoso, J. M.; Domenech-Garret, J. L.; Conde, L.

    2016-01-01

    The interaction between an electron emissive wall, electrically biased in a plasma, is revisited through a simple fluid model. We search for realistic conditions of the existence of a non-monotonic plasma potential profile with a virtual cathode as it is observed in several experiments. We mainly focus our attention on thermionic emission related to the operation of emissive probes for plasma diagnostics, although most conclusions also apply to other electron emission processes. An extended Bohm criterion is derived involving the ratio between the two different electron densities at the potential minimum and at the background plasma. The model allows a phase-diagram analysis, which confirms the existence of the non-monotonic potential profiles with a virtual cathode. This analysis shows that the formation of the potential well critically depends on the emitted electron current and on the velocity at the sheath edge of cold ions flowing from the bulk plasma. As a consequence, a threshold value of the governing parameter is required, in accordance to the physical nature of the electron emission process. The latter is a threshold wall temperature in the case of thermionic electrons. Experimental evidence supports our numerical calculations of this threshold temperature. Besides this, the potential well becomes deeper with increasing electron emission, retaining a fraction of the released current which limits the extent of the bulk plasma perturbation. This noninvasive property would explain the reliable measurements of plasma potential by using the floating potential method of emissive probes operating in the so-called strong emission regime

  10. Existence of a virtual cathode close to a strongly electron emissive wall in low density plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Tierno, S. P., E-mail: sp.tierno@upm.es; Donoso, J. M.; Domenech-Garret, J. L.; Conde, L. [Department of Applied Physics, E.T.S.I. Aeronáutica y del Espacio. Universidad Politécnica de Madrid, 28040 Madrid (Spain)

    2016-01-15

    The interaction between an electron emissive wall, electrically biased in a plasma, is revisited through a simple fluid model. We search for realistic conditions of the existence of a non-monotonic plasma potential profile with a virtual cathode as it is observed in several experiments. We mainly focus our attention on thermionic emission related to the operation of emissive probes for plasma diagnostics, although most conclusions also apply to other electron emission processes. An extended Bohm criterion is derived involving the ratio between the two different electron densities at the potential minimum and at the background plasma. The model allows a phase-diagram analysis, which confirms the existence of the non-monotonic potential profiles with a virtual cathode. This analysis shows that the formation of the potential well critically depends on the emitted electron current and on the velocity at the sheath edge of cold ions flowing from the bulk plasma. As a consequence, a threshold value of the governing parameter is required, in accordance to the physical nature of the electron emission process. The latter is a threshold wall temperature in the case of thermionic electrons. Experimental evidence supports our numerical calculations of this threshold temperature. Besides this, the potential well becomes deeper with increasing electron emission, retaining a fraction of the released current which limits the extent of the bulk plasma perturbation. This noninvasive property would explain the reliable measurements of plasma potential by using the floating potential method of emissive probes operating in the so-called strong emission regime.

  11. Existence of a virtual cathode close to a strongly electron emissive wall in low density plasmas

    Science.gov (United States)

    Tierno, S. P.; Donoso, J. M.; Domenech-Garret, J. L.; Conde, L.

    2016-01-01

    The interaction between an electron emissive wall, electrically biased in a plasma, is revisited through a simple fluid model. We search for realistic conditions of the existence of a non-monotonic plasma potential profile with a virtual cathode as it is observed in several experiments. We mainly focus our attention on thermionic emission related to the operation of emissive probes for plasma diagnostics, although most conclusions also apply to other electron emission processes. An extended Bohm criterion is derived involving the ratio between the two different electron densities at the potential minimum and at the background plasma. The model allows a phase-diagram analysis, which confirms the existence of the non-monotonic potential profiles with a virtual cathode. This analysis shows that the formation of the potential well critically depends on the emitted electron current and on the velocity at the sheath edge of cold ions flowing from the bulk plasma. As a consequence, a threshold value of the governing parameter is required, in accordance to the physical nature of the electron emission process. The latter is a threshold wall temperature in the case of thermionic electrons. Experimental evidence supports our numerical calculations of this threshold temperature. Besides this, the potential well becomes deeper with increasing electron emission, retaining a fraction of the released current which limits the extent of the bulk plasma perturbation. This noninvasive property would explain the reliable measurements of plasma potential by using the floating potential method of emissive probes operating in the so-called strong emission regime.

  12. Anode front-end electronics for the cathode strip chambers of the CMS Endcap Muon detector

    International Nuclear Information System (INIS)

    Ferguson, T.; Bondar, N.; Golyash, A.; Sedov, V.; Terentiev, N.; Vorobiev, I.

    2005-01-01

    The front-end electronics system for the anode signals of the CMS Endcap Muon cathode strip chambers has about 183,000 channels. The purposes of the anode front-end electronics are to acquire precise muon timing information for bunch crossing number identification at the Level-1 muon trigger system and to provide a coarse radial position of the muon track. Each anode channel consists of an input protection network, amplifier, shaper, constant-fraction discriminator, and a programmable delay. The essential parts of the electronics include a 16-channel amplifier-shaper-discriminator ASIC CMP16 and a 16-channel ASIC D16G providing programmable time delay. The ASIC CMP16 was optimized for the large cathode chamber size (up to 3x2.5 m 2 ) and for the large input capacitance (up to 200 pF). The ASIC combines low power consumption (30 mW/channel) with good time resolution (2-3 ns). The delay ASIC D16G makes possible the alignment of signals with an accuracy of 2.2 ns. This paper presents the anode front-end electronics structure and results of the preproduction and the mass production tests, including radiation resistance and reliability tests. The special set of test equipment, techniques, and corresponding software developed and used in the test procedures are also described

  13. Copper current collectors reduce long-term fouling of air cathodes in microbial fuel cells

    KAUST Repository

    Myung, Jaewook; Yang, Wulin; Saikaly, Pascal; Logan, Bruce E

    2018-01-01

    Long-term operation of wastewater-fed, microbial fuel cells (MFCs) with cathodes made of activated carbon and stainless steel (SS) current collectors can result in decreased performance due to cathode fouling. Copper has good antimicrobial properties, and it is more electrically conductive than SS. To demonstrate that a copper current collector could produce a more fouling resistant cathode, MFCs with air cathodes using either SS or copper current collectors were operated using domestic wastewater for 27 weeks. The reduction in biofouling over time was shown by less biofilm formation on the copper cathode surface compared to SS cathodes, due to the antimicrobial properties of copper. Maximum power densities from 17–27 weeks were 440 ± 38 mW/m2 using copper and 370 ± 21 mW/m2 using SS cathodes. The main difference in the microbial community was a nitrifying community on the SS cathodes, which was not present on the copper cathodes.

  14. Copper current collectors reduce long-term fouling of air cathodes in microbial fuel cells

    KAUST Repository

    Myung, Jaewook

    2018-02-05

    Long-term operation of wastewater-fed, microbial fuel cells (MFCs) with cathodes made of activated carbon and stainless steel (SS) current collectors can result in decreased performance due to cathode fouling. Copper has good antimicrobial properties, and it is more electrically conductive than SS. To demonstrate that a copper current collector could produce a more fouling resistant cathode, MFCs with air cathodes using either SS or copper current collectors were operated using domestic wastewater for 27 weeks. The reduction in biofouling over time was shown by less biofilm formation on the copper cathode surface compared to SS cathodes, due to the antimicrobial properties of copper. Maximum power densities from 17–27 weeks were 440 ± 38 mW/m2 using copper and 370 ± 21 mW/m2 using SS cathodes. The main difference in the microbial community was a nitrifying community on the SS cathodes, which was not present on the copper cathodes.

  15. A new thin film deposition process by cathodic plasma electrolysis

    International Nuclear Information System (INIS)

    Paulmier, T.; Kiriakos, E.; Bell, J.; Fredericks, P.

    2004-01-01

    Full text: A new technique, called atmospheric pressure plasma deposition (APPD), has been developed since a few years for the deposition of carbon and DLC, Titanium or Silicon films on metal and metal alloys substrates. A high voltage (2kV) is applied in a liquid electrolytic solution between an anode and a cathode, both electrodes being cylindrical: a glow discharge is then produced and confined at the vicinity of the cathode. The physic of the plasma in the electrolytic solution near the cathode is very different form the other techniques of plasma deposition since the pressure is here close to the atmospheric pressure. We describe here the different physico-chemical processes occurring during the process. In this cathodic process, the anodic area is significantly larger than the cathode area. In a first step, the electrolytic solution is heated by Joule effect induced by the high voltage between the electrodes. Due to the high current density, the vaporization of the solution occurs near the cathode: a large amount of bubbles are produced which are stabilized at the electrode by hydrodynamic and electromagnetic forces, forming a vapour sheath. The electric field and voltage drop are then concentrated in this gas envelope, inducing the ionization of the gas and the ignition of a glow discharge at the surface of the material. This plasma induces the formation of ionized and reactive species which diffuse and are accelerated toward the cathode. These excited species are the precursors for the formation of the deposition material. At the same time, the glow discharge interacts with the electrolyte solution inducing also ionization, convection and polymerization processes in the liquid: the solution is therefore a second source of the deposition material. A wide range of films have been deposited with a thickness up to 10 micrometers. These films have been analyzed by SEM and Raman spectroscopy. The electrolytic solution has been characterized by GC-MS and the

  16. The feasibility and application of PPy in cathodic polarization antifouling.

    Science.gov (United States)

    Jia, Meng-Yang; Zhang, Zhi-Ming; Yu, Liang-Min; Wang, Jia; Zheng, Tong-Tong

    2018-04-01

    Cathodic polarization antifouling deserves attention because of its environmentally friendly nature and good sustainability. It has been proven that cathodic voltages applied on metal substrates exhibit outstanding antifouling effects. However, most metals immersed in marine environment are protected by insulated anticorrosive coatings, restricting the cathodic polarization applied on metals. This study developed a conducting polypyrrole (PPy)/acrylic resin coating (σ = 0.18 Scm -1 ), which can be applied in cathodic polarization antifouling. The good stability and electro-activity of PPy in the negative polarity zone in alkalescent NaCl solution were verified by linear sweep voltammetry (LSV), chronoamperometry (CA), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), demonstrating the feasibility of PPy as cathodic polarization material. Furthermore, the antifouling effects of PPy/acrylicresin coating on 24-h old Escherichia coli bacteria (E. coli) which formed on PPy/acrylic resin-coated plastic plate were measured under different cathodic potentials and treatment time, characterized by fluorescent microscope. The results suggest that at cathodic potential around -0.5 V (vs. saturated calomel electrode (SCE)), there was little trace of attached bacteria on the substrate after 20 min of treatment. PPy/acrylicresin-coated substrates were also subjected to repeated cycles of biofilm formation and electrochemical removal, where high removal efficiencies were maintained throughout the total polarization process. Under these conditions, the generation of hydrogen peroxide is believed to be responsible for the antifouling effects because of causing oxidative damage to cells, suggesting the potential of the proposed technology for application on insulated surfaces in various industrial settings. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Post-Removal Examination of GTF Cathode No.2

    International Nuclear Information System (INIS)

    Kirby, R.

    2005-01-01

    This photo-cathode (PC), GTF Cathode No.2, was removed from the GTF in October, 2000. It was characterized in September, 1999 by G. Mulhollan and me (Report entitled ''A Brief Report on a Brief Examination of the Electropolished GTF Cathode'', LCLS-TN-99-10). The cathode conditions and results of that exam were: (1) The cathode was conventionally machined and cleaned in the SLAC Plating Shop. (2) The machining process left a central defect (400 microns diameter) which was not removed by electropolishing. (3) The electropolished surface was ''orange-peeled'', typical of excessive polishing. (4) Secondary electron microscopy (SEM) examination showed numerous 10 micron-diameter etch pits and a small number of copper surface particles. Operation of this cathode in the GTF exhibited ''holloW--beam'' behavior, suggesting that the central defect may have been responsible for non-normal emergence of the photo-emitted beam. No laser cleaning of the cathode was done, so all arc features are due to breakdowns. Post-removal analysis consisted of loW--magnification digital camera pictures (taken with glancing-incidence tungsten white light illumination, to emphasize particles/pitting) and SEM. All images are available in digital (TIFF) form. Also available is a Power Point presentation of the results. Contact me for either. These image files are high-resolution and, thus, large in size. A 200K loW--resolution contact sheet of a few images is attached to this report. Images are referred to by file name

  18. Care relationships at stake? Home healthcare professionals' experiences with digital medicine dispensers - a qualitative study.

    Science.gov (United States)

    Nakrem, Sigrid; Solbjør, Marit; Pettersen, Ida Nilstad; Kleiven, Hanne Hestvik

    2018-01-15

    Although digital technologies can mitigate the burdens of home healthcare services caused by an ageing population that lives at home longer with complex health problems, research on the impacts and consequences of digitalised remote communication between patients and caregivers is lacking. The present study explores how home healthcare professionals had experienced the introduction of digital medicine dispensers and their influence on patient-caregiver relationships. The multi-case study comprised semi-structured interviews with 21 healthcare professionals whose home healthcare service involved using the digital medicine dispensers. The constant comparative method was used for data analyses. Altogether, interviewed healthcare professionals reported three main technology-related impacts upon their patient-caregiver relationships. First, national and local pressure to increase efficiency had troubled their relationships with patients who suspected that municipalities have sought to lower costs by reducing and digitalising services. Participants reported having to consider such worries when introducing technologies into their services. Second, participants reported a shift towards empowering patients. Digital technology can empower patients who value their independence, whereas safety is more important for other patients. Healthcare professionals needed to ensure that replacing care tasks with technology implies safe and improved care. Third, the safety and quality of digital healthcare services continues to depend upon surveillance and control mechanisms that compensate for less face-to-face monitoring. Participants did not consider the possibility that surveillance exposes information about patients' everyday lives to be problematic, but to constitute opportunities for adjusting services to meet patients' needs. Technologies such as digital medicine dispensers can improve the efficiency of healthcare services and enhance patients' independence when introduced in a

  19. [Monitoring medication errors in personalised dispensing using the Sentinel Surveillance System method].

    Science.gov (United States)

    Pérez-Cebrián, M; Font-Noguera, I; Doménech-Moral, L; Bosó-Ribelles, V; Romero-Boyero, P; Poveda-Andrés, J L

    2011-01-01

    To assess the efficacy of a new quality control strategy based on daily randomised sampling and monitoring a Sentinel Surveillance System (SSS) medication cart, in order to identify medication errors and their origin at different levels of the process. Prospective quality control study with one year follow-up. A SSS medication cart was randomly selected once a week and double-checked before dispensing medication. Medication errors were recorded before it was taken to the relevant hospital ward. Information concerning complaints after receiving medication and 24-hour monitoring were also noted. Type and origin error data were assessed by a Unit Dose Quality Control Group, which proposed relevant improvement measures. Thirty-four SSS carts were assessed, including 5130 medication lines and 9952 dispensed doses, corresponding to 753 patients. Ninety erroneous lines (1.8%) and 142 mistaken doses (1.4%) were identified at the Pharmacy Department. The most frequent error was dose duplication (38%) and its main cause inappropriate management and forgetfulness (69%). Fifty medication complaints (6.6% of patients) were mainly due to new treatment at admission (52%), and 41 (0.8% of all medication lines), did not completely match the prescription (0.6% lines) as recorded by the Pharmacy Department. Thirty-seven (4.9% of patients) medication complaints due to changes at admission and 32 matching errors (0.6% medication lines) were recorded. The main cause also was inappropriate management and forgetfulness (24%). The simultaneous recording of incidences due to complaints and new medication coincided in 33.3%. In addition, 433 (4.3%) of dispensed doses were returned to the Pharmacy Department. After the Unit Dose Quality Control Group conducted their feedback analysis, 64 improvement measures for Pharmacy Department nurses, 37 for pharmacists, and 24 for the hospital ward were introduced. The SSS programme has proven to be useful as a quality control strategy to identify Unit

  20. What proportion of prescription items dispensed in community pharmacies are eligible for the New Medicine Service?

    Science.gov (United States)

    Wells, Katharine M; Boyd, Matthew J; Thornley, Tracey; Boardman, Helen F

    2014-03-07

    The payment structure for the New Medicine Service (NMS) in England is based on the assumption that 0.5% of prescription items dispensed in community pharmacies are eligible for the service. This assumption is based on a theoretical calculation. This study aimed to find out the actual proportion of prescription items eligible for the NMS dispensed in community pharmacies in order to compare this with the theoretical assumption. The study also aimed to investigate whether the proportion of prescription items eligible for the NMS is affected by pharmacies' proximity to GP practices. The study collected data from eight pharmacies in Nottingham belonging to the same large chain of pharmacies. Pharmacies were grouped by distance from the nearest GP practice and sampled to reflect the distribution by distance of all pharmacies in Nottingham. Data on one thousand consecutive prescription items were collected from each pharmacy and the number of NMS eligible items recorded. All NHS prescriptions were included in the sample. Data were analysed and proportions calculated with 95% confidence intervals used to compare the study results against the theoretical figure of 0.5% of prescription items being eligible for the NMS. A total of 8005 prescription items were collected (a minimum of 1000 items per pharmacy) of which 17 items were eligible to receive the service. The study found that 0.25% (95% confidence intervals: 0.14% to 0.36%) of prescription items were eligible for the NMS which differs significantly from the theoretical assumption of 0.5%. The opportunity rate for the service was lower, 0.21% (95% confidence intervals: 0.10% to 0.32%) of items, as some items eligible for the NMS did not translate into opportunities to offer the service. Of all the prescription items collected in the pharmacies, 28% were collected by patient representatives. The results of this study show that the proportion of items eligible for the NMS dispensed in community pharmacies is lower than