WorldWideScience

Sample records for reliable diagnostic method

  1. Method matters: Understanding diagnostic reliability in DSM-IV and DSM-5.

    Science.gov (United States)

    Chmielewski, Michael; Clark, Lee Anna; Bagby, R Michael; Watson, David

    2015-08-01

    Diagnostic reliability is essential for the science and practice of psychology, in part because reliability is necessary for validity. Recently, the DSM-5 field trials documented lower diagnostic reliability than past field trials and the general research literature, resulting in substantial criticism of the DSM-5 diagnostic criteria. Rather than indicating specific problems with DSM-5, however, the field trials may have revealed long-standing diagnostic issues that have been hidden due to a reliance on audio/video recordings for estimating reliability. We estimated the reliability of DSM-IV diagnoses using both the standard audio-recording method and the test-retest method used in the DSM-5 field trials, in which different clinicians conduct separate interviews. Psychiatric patients (N = 339) were diagnosed using the SCID-I/P; 218 were diagnosed a second time by an independent interviewer. Diagnostic reliability using the audio-recording method (N = 49) was "good" to "excellent" (M κ = .80) and comparable to the DSM-IV field trials estimates. Reliability using the test-retest method (N = 218) was "poor" to "fair" (M κ = .47) and similar to DSM-5 field-trials' estimates. Despite low test-retest diagnostic reliability, self-reported symptoms were highly stable. Moreover, there was no association between change in self-report and change in diagnostic status. These results demonstrate the influence of method on estimates of diagnostic reliability. (c) 2015 APA, all rights reserved).

  2. Reliability studies of diagnostic methods in Indian traditional Ayurveda medicine: An overview

    Science.gov (United States)

    Kurande, Vrinda Hitendra; Waagepetersen, Rasmus; Toft, Egon; Prasad, Ramjee

    2013-01-01

    Recently, a need to develop supportive new scientific evidence for contemporary Ayurveda has emerged. One of the research objectives is an assessment of the reliability of diagnoses and treatment. Reliability is a quantitative measure of consistency. It is a crucial issue in classification (such as prakriti classification), method development (pulse diagnosis), quality assurance for diagnosis and treatment and in the conduct of clinical studies. Several reliability studies are conducted in western medicine. The investigation of the reliability of traditional Chinese, Japanese and Sasang medicine diagnoses is in the formative stage. However, reliability studies in Ayurveda are in the preliminary stage. In this paper, examples are provided to illustrate relevant concepts of reliability studies of diagnostic methods and their implication in practice, education, and training. An introduction to reliability estimates and different study designs and statistical analysis is given for future studies in Ayurveda. PMID:23930037

  3. Cervical vertebral maturation method and mandibular growth peak: a longitudinal study of diagnostic reliability.

    Science.gov (United States)

    Perinetti, Giuseppe; Primozic, Jasmina; Sharma, Bhavna; Cioffi, Iacopo; Contardo, Luca

    2018-03-28

    The capability of the cervical vertebral maturation (CVM) method in the identification of the mandibular growth peak on an individual basis remains undetermined. The diagnostic reliability of the six-stage CVM method in the identification of the mandibular growth peak was thus investigated. From the files of the Oregon and Burlington Growth Studies (data obtained between early 1950s and middle 1970s), 50 subjects (26 females, 24 males) with at least seven annual lateral cephalograms taken from 9 to 16 years were identified. Cervical vertebral maturation was assessed according to the CVM code staging system, and mandibular growth was defined as annual increments in Co-Gn distance. A diagnostic reliability analysis was carried out to establish the capability of the circumpubertal CVM stages 2, 3, and 4 in the identification of the imminent mandibular growth peak. Variable durations of each of the CVM stages 2, 3, and 4 were seen. The overall diagnostic accuracy values for the CVM stages 2, 3, and 4 were 0.70, 0.76, and 0.77, respectively. These low values appeared to be due to false positive cases. Secular trends in conjunction with the use of a discrete staging system. In most of the Burlington Growth Study sample, the lateral head film at age 15 was missing. None of the CVM stages 2, 3, and 4 reached a satisfactorily diagnostic reliability in the identification of imminent mandibular growth peak.

  4. Selection and reporting of statistical methods to assess reliability of a diagnostic test: Conformity to recommended methods in a peer-reviewed journal

    International Nuclear Information System (INIS)

    Park, Ji Eun; Sung, Yu Sub; Han, Kyung Hwa

    2017-01-01

    To evaluate the frequency and adequacy of statistical analyses in a general radiology journal when reporting a reliability analysis for a diagnostic test. Sixty-three studies of diagnostic test accuracy (DTA) and 36 studies reporting reliability analyses published in the Korean Journal of Radiology between 2012 and 2016 were analyzed. Studies were judged using the methodological guidelines of the Radiological Society of North America-Quantitative Imaging Biomarkers Alliance (RSNA-QIBA), and COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) initiative. DTA studies were evaluated by nine editorial board members of the journal. Reliability studies were evaluated by study reviewers experienced with reliability analysis. Thirty-one (49.2%) of the 63 DTA studies did not include a reliability analysis when deemed necessary. Among the 36 reliability studies, proper statistical methods were used in all (5/5) studies dealing with dichotomous/nominal data, 46.7% (7/15) of studies dealing with ordinal data, and 95.2% (20/21) of studies dealing with continuous data. Statistical methods were described in sufficient detail regarding weighted kappa in 28.6% (2/7) of studies and regarding the model and assumptions of intraclass correlation coefficient in 35.3% (6/17) and 29.4% (5/17) of studies, respectively. Reliability parameters were used as if they were agreement parameters in 23.1% (3/13) of studies. Reproducibility and repeatability were used incorrectly in 20% (3/15) of studies. Greater attention to the importance of reporting reliability, thorough description of the related statistical methods, efforts not to neglect agreement parameters, and better use of relevant terminology is necessary

  5. Selection and reporting of statistical methods to assess reliability of a diagnostic test: Conformity to recommended methods in a peer-reviewed journal

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Eun; Sung, Yu Sub [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Han, Kyung Hwa [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of); and others

    2017-11-15

    To evaluate the frequency and adequacy of statistical analyses in a general radiology journal when reporting a reliability analysis for a diagnostic test. Sixty-three studies of diagnostic test accuracy (DTA) and 36 studies reporting reliability analyses published in the Korean Journal of Radiology between 2012 and 2016 were analyzed. Studies were judged using the methodological guidelines of the Radiological Society of North America-Quantitative Imaging Biomarkers Alliance (RSNA-QIBA), and COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) initiative. DTA studies were evaluated by nine editorial board members of the journal. Reliability studies were evaluated by study reviewers experienced with reliability analysis. Thirty-one (49.2%) of the 63 DTA studies did not include a reliability analysis when deemed necessary. Among the 36 reliability studies, proper statistical methods were used in all (5/5) studies dealing with dichotomous/nominal data, 46.7% (7/15) of studies dealing with ordinal data, and 95.2% (20/21) of studies dealing with continuous data. Statistical methods were described in sufficient detail regarding weighted kappa in 28.6% (2/7) of studies and regarding the model and assumptions of intraclass correlation coefficient in 35.3% (6/17) and 29.4% (5/17) of studies, respectively. Reliability parameters were used as if they were agreement parameters in 23.1% (3/13) of studies. Reproducibility and repeatability were used incorrectly in 20% (3/15) of studies. Greater attention to the importance of reporting reliability, thorough description of the related statistical methods, efforts not to neglect agreement parameters, and better use of relevant terminology is necessary.

  6. Reliability and diagnostic of modular systems

    Directory of Open Access Journals (Sweden)

    J. Kohlas

    2014-01-01

    Full Text Available Reliability and diagnostic are in general two problems discussed separately. Yet the two problems are in fact closely related to each other. Here, this relation is considered in the simple case of modular systems. We show, how the computation of reliability and diagnostic can efficiently be done within the same Bayesian network induced by the modularity of the structure function of the system.

  7. Diagnostic reliability of MMPI-2 computer-based test interpretations.

    Science.gov (United States)

    Pant, Hina; McCabe, Brian J; Deskovitz, Mark A; Weed, Nathan C; Williams, John E

    2014-09-01

    Reflecting the common use of the MMPI-2 to provide diagnostic considerations, computer-based test interpretations (CBTIs) also typically offer diagnostic suggestions. However, these diagnostic suggestions can sometimes be shown to vary widely across different CBTI programs even for identical MMPI-2 profiles. The present study evaluated the diagnostic reliability of 6 commercially available CBTIs using a 20-item Q-sort task developed for this study. Four raters each sorted diagnostic classifications based on these 6 CBTI reports for 20 MMPI-2 profiles. Two questions were addressed. First, do users of CBTIs understand the diagnostic information contained within the reports similarly? Overall, diagnostic sorts of the CBTIs showed moderate inter-interpreter diagnostic reliability (mean r = .56), with sorts for the 1/2/3 profile showing the highest inter-interpreter diagnostic reliability (mean r = .67). Second, do different CBTIs programs vary with respect to diagnostic suggestions? It was found that diagnostic sorts of the CBTIs had a mean inter-CBTI diagnostic reliability of r = .56, indicating moderate but not strong agreement across CBTIs in terms of diagnostic suggestions. The strongest inter-CBTI diagnostic agreement was found for sorts of the 1/2/3 profile CBTIs (mean r = .71). Limitations and future directions are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  8. THE SIMULATION DIAGNOSTIC METHODS AND REGENERATION WAYS OF REINFORCED - CONCRETE CONSTRUCTIONS OF BRIDGES IN PROVIDING THEIR OPERATING RELIABILITY AND LONGEVITY

    OpenAIRE

    B. V. Savchinskiy

    2010-01-01

    On the basis of analysis of existing diagnostic methods and regeneration ways of reinforced-concrete constructions of bridges the recommendations on introduction of new modern technologies of renewal of reinforced-concrete constructions of bridges in providing their operating reliability and longevity are offered.

  9. THE SIMULATION DIAGNOSTIC METHODS AND REGENERATION WAYS OF REINFORCED - CONCRETE CONSTRUCTIONS OF BRIDGES IN PROVIDING THEIR OPERATING RELIABILITY AND LONGEVITY

    Directory of Open Access Journals (Sweden)

    B. V. Savchinskiy

    2010-03-01

    Full Text Available On the basis of analysis of existing diagnostic methods and regeneration ways of reinforced-concrete constructions of bridges the recommendations on introduction of new modern technologies of renewal of reinforced-concrete constructions of bridges in providing their operating reliability and longevity are offered.

  10. Reliability studies of diagnostic methods in Indian traditional Ayurveda medicine

    DEFF Research Database (Denmark)

    Kurande, Vrinda Hitendra; Waagepetersen, Rasmus; Toft, Egon

    2013-01-01

    as prakriti classification), method development (pulse diagnosis), quality assurance for diagnosis and treatment and in the conduct of clinical studies. Several reliability studies are conducted in western medicine. The investigation of the reliability of traditional Chinese, Japanese and Sasang medicine...

  11. Method for assessing the reliability of molecular diagnostics based on multiplexed SERS-coded nanoparticles.

    Directory of Open Access Journals (Sweden)

    Steven Y Leigh

    Full Text Available Surface-enhanced Raman scattering (SERS nanoparticles have been engineered to generate unique fingerprint spectra and are potentially useful as bright contrast agents for molecular diagnostics. One promising strategy for biomedical diagnostics and imaging is to functionalize various particle types ("flavors", each emitting a unique spectral signature, to target a large multiplexed panel of molecular biomarkers. While SERS particles emit narrow spectral features that allow them to be easily separable under ideal conditions, the presence of competing noise sources and background signals such as detector noise, laser background, and autofluorescence confounds the reliability of demultiplexing algorithms. Results obtained during time-constrained in vivo imaging experiments may not be reproducible or accurate. Therefore, our goal is to provide experimentalists with a metric that may be monitored to enforce a desired bound on accuracy within a user-defined confidence level. We have defined a spectral reliability index (SRI, based on the output of a direct classical least-squares (DCLS demultiplexing routine, which provides a measure of the reliability of the computed nanoparticle concentrations and ratios. We present simulations and experiments to demonstrate the feasibility of this strategy, which can potentially be utilized for a range of instruments and biomedical applications involving multiplexed SERS nanoparticles.

  12. Reliability of measuring pelvic floor elevation with a diagnostic ultrasonic imaging device

    OpenAIRE

    Ubukata, Hitomi; Maruyama, Hitoshi; Huo, Ming

    2015-01-01

    [Purpose] The purpose of this study was to investigate the reliability of measuring the amount of pelvic floor elevation during pelvic and abdominal muscle contraction with a diagnostic ultrasonic imaging device. [Subjects] The study group comprised 11 healthy women without urinary incontinence or previous birth experience. [Methods] We measured the displacement elevation of the bladder base during contraction of the abdominal and pelvic floor muscles was measured using a diagnostic ultrasoni...

  13. Diagnostics and reliability of pipeline systems

    CERN Document Server

    Timashev, Sviatoslav

    2016-01-01

    The book contains solutions to fundamental problems which arise due to the logic of development of specific branches of science, which are related to pipeline safety, but mainly are subordinate to the needs of pipeline transportation.          The book deploys important but not yet solved aspects of reliability and safety assurance of pipeline systems, which are vital aspects not only for the oil and gas industry and, in general, fuel and energy industries , but also to virtually all contemporary industries and technologies. The volume will be useful to specialists and experts in the field of diagnostics/ inspection, monitoring, reliability and safety of critical infrastructures. First and foremost, it will be useful to the decision making persons —operators of different types of pipelines, pipeline diagnostics/inspection vendors, and designers of in-line –inspection (ILI) tools, industrial and ecological safety specialists, as well as to researchers and graduate students.

  14. Fault-tolerant and Diagnostic Methods for Navigation

    DEFF Research Database (Denmark)

    Blanke, Mogens

    2003-01-01

    to diagnose faults and autonomously provide valid navigation data, disregarding any faulty sensor data and use sensor fusion to obtain a best estimate for users. This paper discusses how diagnostic and fault-tolerant methods are applicable in marine systems. An example chosen is sensor fusion for navigation......Precise and reliable navigation is crucial, and for reasons of safety, essential navigation instruments are often duplicated. Hardware redundancy is mostly used to manually switch between instruments should faults occur. In contrast, diagnostic methods are available that can use analytic redundancy...

  15. Reliability and validity of a Chinese version of the Diagnostic Interview for Borderlines-Revised.

    Science.gov (United States)

    Wang, Lanlan; Yuan, Chenmei; Qiu, Jianying; Gunderson, John; Zhang, Min; Jiang, Kaida; Leung, Freedom; Zhong, Jie; Xiao, Zeping

    2014-09-01

    Borderline personality disorder (BPD) is the most studied of the axis II disorders. One of the most widely used diagnostic instruments is the Diagnostic Interview for Borderline Patients-Revised (DIB-R). The aim of this study was to test the reliability and validity of DIB-R for use in the Chinese culture. The reliability and validity of the DIB-R Chinese version were assessed in a sample of 236 outpatients with a probable BPD diagnosis. The Structured Clinical Interview for DSM-IV Personality Disorders (SCID-II) was used as a standard. Test-retest reliability was tested six months later with 20 patients, and inter-rater reliability was tested on 32 patients. The Chinese version of the DIB-R showed good internal global consistency (Cronbach's α of 0.916), good test-retest reliability (Pearson correlation of 0.704), good inter-rater reliability (intra-class correlation coefficient of 0.892 and kappa of 0.861). When compared with the DSM-IV diagnosis as measured by the SCID-II, the DIB-R showed relatively good sensitivity (0.768) and specificity (0.891) at the cutoff of 7, moderate diagnostic convergence (kappa of 0.631), as well as good discriminating validity. The Chinese version of the DIB-R has good psychometric properties, which renders it a valuable method for examining the presence, the severity, and component phenotypes of BPD in Chinese samples. © 2013 Wiley Publishing Asia Pty Ltd.

  16. Reliability and Validity of Autism Diagnostic Interview-Revised, Japanese Version

    Science.gov (United States)

    Tsuchiya, Kenji J.; Matsumoto, Kaori; Yagi, Atsuko; Inada, Naoko; Kuroda, Miho; Inokuchi, Eiko; Koyama, Tomonori; Kamio, Yoko; Tsujii, Masatsugu; Sakai, Saeko; Mohri, Ikuko; Taniike, Masako; Iwanaga, Ryoichiro; Ogasahara, Kei; Miyachi, Taishi; Nakajima, Shunji; Tani, Iori; Ohnishi, Masafumi; Inoue, Masahiko; Nomura, Kazuyo; Hagiwara, Taku; Uchiyama, Tokio; Ichikawa, Hironobu; Kobayashi, Shuji; Miyamoto, Ken; Nakamura, Kazuhiko; Suzuki, Katsuaki; Mori, Norio; Takei, Nori

    2013-01-01

    To examine the inter-rater reliability of Autism Diagnostic Interview-Revised, Japanese Version (ADI-R-JV), the authors recruited 51 individuals aged 3-19 years, interviewed by two independent raters. Subsequently, to assess the discriminant and diagnostic validity of ADI-R-JV, the authors investigated 317 individuals aged 2-19 years, who were…

  17. Telepsychiatry clinical decision support system used by non-psychiatrists in remote areas: Validity & reliability of diagnostic module

    Science.gov (United States)

    Malhotra, Savita; Chakrabarti, Subho; Shah, Ruchita; Sharma, Minali; Sharma, Kanu Priya; Malhotra, Akanksha; Upadhyaya, Suneet K.; Margoob, Mushtaq A.; Maqbool, Dar; Jassal, Gopal D.

    2017-01-01

    Background & objectives: A knowledge-based, logically-linked online telepsychiatric decision support system for diagnosis and treatment of mental disorders was developed and validated. We evaluated diagnostic accuracy and reliability of the application at remote sites when used by non-psychiatrists who underwent a brief training in its use through video-conferencing. Methods: The study was conducted at a nodal telepsychiatry centre, and three geographically remote peripheral centres. The diagnostic tool of application had a screening followed by detailed criteria-wise diagnostic modules for 18 psychiatric disorders. A total of 100 consecutive consenting adult outpatients attending remote telepsychiatry centres were included. To assess inter-rater reliability, patients were interviewed face to face by non-specialists at remote sites using the application (active interviewer) and simultaneously on online application via video-conferencing by a passive assessor at nodal centre. Another interviewer at the nodal centre rated the patient using Mini-International Neuropsychiatric Interview (MINI) for diagnostic validation. Results: Screening sub-module had high sensitivity (80-100%), low positive predictive values (PPV) (0.10-0.71) but high negative predictive value (NPV) (0.97-1) for most disorders. For the diagnostic sub-modules, Cohen's kappa was >0.4 for all disorders, with kappa of 0.7-1.0 for most disorders. PPV and NPV were high for most disorders. Inter-rater agreement analysis revealed kappa >0.6 for all disorders. Interpretation & conclusions: Diagnostic tool showed acceptable to good validity and reliability when used by non-specialists at remote sites. Our findings show that diagnostic tool of the telepsychiatry application has potential to empower non-psychiatrist doctors and paramedics to diagnose psychiatric disorders accurately and reliably in remote sites. PMID:29265020

  18. Systematic review of reliability and diagnostic validity of joint vibration analysis for diagnosis of temporomandibular disorders.

    Science.gov (United States)

    Sharma, Sonia; Crow, Heidi C; McCall, W D; Gonzalez, Yoly M

    2013-01-01

    To conduct a systematic review of papers reporting the reliability and diagnostic validity of the joint vibration analysis (JVA) for diagnosis of temporomandibular disorders (TMD). A search of Pubmed identified English-language publications of the reliability and diagnostic validity of the JVA. Guidelines were adapted from applied STAndards for the Reporting of Diagnostic accuracy studies (STARD) to evaluate the publications. Fifteen publications were included in this review, each of which presented methodological limitations. This literature is unable to provide evidence to support the reliability and diagnostic validity of the JVA for diagnosis of TMD.

  19. Binge Eating Disorder: Reliability and Validity of a New Diagnostic Category.

    Science.gov (United States)

    Brody, Michelle L.; And Others

    1994-01-01

    Examined reliability and validity of binge eating disorder (BED), proposed for inclusion in Diagnostic and Statistical Manual of Mental Disorders (DSM), fourth edition. Interrater reliability of BED diagnosis compared favorably with that of most diagnoses in DSM revised third edition. Study comparing obese individuals with and without BED and…

  20. Semiconductor laser engineering, reliability and diagnostics a practical approach to high power and single mode devices

    CERN Document Server

    Epperlein, Peter W

    2013-01-01

    This reference book provides a fully integrated novel approach to the development of high-power, single-transverse mode, edge-emitting diode lasers by addressing the complementary topics of device engineering, reliability engineering and device diagnostics in the same book, and thus closes the gap in the current book literature. Diode laser fundamentals are discussed, followed by an elaborate discussion of problem-oriented design guidelines and techniques, and by a systematic treatment of the origins of laser degradation and a thorough exploration of the engineering means to enhance the optical strength of the laser. Stability criteria of critical laser characteristics and key laser robustness factors are discussed along with clear design considerations in the context of reliability engineering approaches and models, and typical programs for reliability tests and laser product qualifications. Novel, advanced diagnostic methods are reviewed to discuss, for the first time in detail in book literature, performa...

  1. Diagnostic reliability of the cervical vertebral maturation method and standing height in the identification of the mandibular growth spurt.

    Science.gov (United States)

    Perinetti, Giuseppe; Contardo, Luca; Castaldo, Attilio; McNamara, James A; Franchi, Lorenzo

    2016-07-01

    To evaluate the capability of both cervical vertebral maturation (CVM) stages 3 and 4 (CS3-4 interval) and the peak in standing height to identify the mandibular growth spurt throughout diagnostic reliability analysis. A previous longitudinal data set derived from 24 untreated growing subjects (15 females and nine males,) detailed elsewhere were reanalyzed. Mandibular growth was defined as annual increments in Condylion (Co)-Gnathion (Gn) (total mandibular length) and Co-Gonion Intersection (Goi) (ramus height) and their arithmetic mean (mean mandibular growth [mMG]). Subsequently, individual annual increments in standing height, Co-Gn, Co-Goi, and mMG were arranged according to annual age intervals, with the first and last intervals defined as 7-8 years and 15-16 years, respectively. An analysis was performed to establish the diagnostic reliability of the CS3-4 interval or the peak in standing height in the identification of the maximum individual increments of each Co-Gn, Co-Goi, and mMG measurement at each annual age interval. CS3-4 and standing height peak show similar but variable accuracy across annual age intervals, registering values between 0.61 (standing height peak, Co-Gn) and 0.95 (standing height peak and CS3-4, mMG). Generally, satisfactory diagnostic reliability was seen when the mandibular growth spurt was identified on the basis of the Co-Goi and mMG increments. Both CVM interval CS3-4 and peak in standing height may be used in routine clinical practice to enhance efficiency of treatments requiring identification of the mandibular growth spurt.

  2. TH-F-209-01: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    International Nuclear Information System (INIS)

    Behling, R.

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  3. TH-F-209-00: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    International Nuclear Information System (INIS)

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  4. TH-F-209-01: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Behling, R. [Philips Medical Systems DMC GmbH (United States)

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  5. TH-F-209-00: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  6. Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines

    Directory of Open Access Journals (Sweden)

    Cameron Alyse FM

    2009-11-01

    Full Text Available Abstract Background Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end Philips HD11 Ultrasound machine and clinically orientated Chison 8300 Deluxe Digital Portable Ultrasound System. Methods The abductor hallucis muscle of both the left and right feet of thirty asymptomatic participants was imaged and then measured using both ultrasound machines. Interclass correlation coefficients (ICC with 95% confidence intervals (CI were used to calculate both within and between session intra-tester reliability. Standard error of the measurement (SEM calculations were undertaken to assess difference between the actual measured score across trials and the smallest real difference (SRD was calculated from the SEM to indicate the degree of change that would exceed the expected trial to trial variability. Results The ICCs, SEM and SRD for dorso-plantar thickness and medial-lateral length were shown to have excellent to high within and between-session reliability for both ultrasound machines. The between-session reliability indices for cross-sectional area were acceptable for both ultrasound machines. Conclusion The results of the current study suggest that regardless of the type ultrasound machine, intra-tester reliability for the measurement the abductor hallucis muscle parameters is very high.

  7. Reliability of self-reported diagnostic radiation history in BRCA1/2 mutation carriers

    International Nuclear Information System (INIS)

    Pijpe, Anouk; Manders, Peggy; Mulder, Renee L.; Leeuwen, Flora E. van; Rookus, Matti A.

    2010-01-01

    We assessed reliability of self-reported diagnostic radiation history in BRCA1/2 mutation carriers with and without breast cancer. Within the frame-work of the HEBON study, 401 BRCA1/2 mutation carriers completed a baseline (1999-2004) and a follow-up questionnaire (2006-2007). Test-retest reliability of self-reported exposure to chest X-rays, fluoroscopies and mammograms was assessed for the entire study population and by case status. Overall proportion agreement on reporting ever/never exposure was good (> 75%), while the corresponding kappa coefficients were between 0.40 and 0.75, indicating at least moderate reliability beyond chance. Reliability of number of exposures was also good (> 75%). Proportion agreement on reporting age at first mammogram was low (40%) for exact consistency and moderate (60%) for consistency ± 1 year. Reliability of age at first mammogram was higher for cases than for unaffected carriers (P < 0.001) but this difference disappeared when excluding diagnostic mammograms (P = 0.60). In unaffected carriers proportion agreement on age at last mammogram was 50%. In general, the direction of disagreement on all items was equally distributed. More consistent reporting was mainly determined by a younger age at questionnaire completion. In conclusion, inconsistent self-report of diagnostic radiation by BRCA1/2 mutation carriers was mainly non-differential by disease status.

  8. Approaches to Demonstrating the Reliability and Validity of Core Diagnostic Criteria for Chronic Pain.

    Science.gov (United States)

    Bruehl, Stephen; Ohrbach, Richard; Sharma, Sonia; Widerstrom-Noga, Eva; Dworkin, Robert H; Fillingim, Roger B; Turk, Dennis C

    2016-09-01

    The Analgesic, Anesthetic, and Addiction Clinical Trial Translations, Innovations, Opportunities, and Networks-American Pain Society Pain Taxonomy (AAPT) is designed to be an evidence-based multidimensional chronic pain classification system that will facilitate more comprehensive and consistent chronic pain diagnoses, and thereby enhance research, clinical communication, and ultimately patient care. Core diagnostic criteria (dimension 1) for individual chronic pain conditions included in the initial version of AAPT will be the focus of subsequent empirical research to evaluate and provide evidence for their reliability and validity. Challenges to validating diagnostic criteria in the absence of clear and identifiable pathophysiological mechanisms are described. Based in part on previous experience regarding the development of evidence-based diagnostic criteria for psychiatric disorders, headache, and specific chronic pain conditions (fibromyalgia, complex regional pain syndrome, temporomandibular disorders, pain associated with spinal cord injuries), several potential approaches for documentation of the reliability and validity of the AAPT diagnostic criteria are summarized. The AAPT is designed to be an evidence-based multidimensional chronic pain classification system. Conceptual and methodological issues related to demonstrating the reliability and validity of the proposed AAPT chronic pain diagnostic criteria are discussed. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.

  9. Empiric reliability of diagnostic and prognostic estimations of physical standards of children, going in for sports.

    Directory of Open Access Journals (Sweden)

    Zaporozhanov V.A.

    2012-12-01

    Full Text Available In the conditions of sporting-pedagogical practices objective estimation of potential possibilities gettings busy already on the initial stages of long-term preparation examined as one of issues of the day. The proper quantitative information allows to individualize preparation of gettings in obedience to requirements to the guided processes busy. Research purpose - logically and metrical to rotin expedience of metrical method of calculations of reliability of results of the control measurings, in-use for diagnostics of psychophysical fitness and prognosis of growth of trade gettings busy in the select type of sport. Material and methods. Analysed the results of the control measurings on four indexes of psychophysical preparedness and estimation of experts of fitness 24th gettings busy composition of children of gymnastic school. The results of initial and final inspection of gymnasts on the same control tests processed the method of mathematical statistics. Expected the metrical estimations of reliability of measurings is stability, co-ordination and informing of control information for current diagnostics and prognosis of sporting possibilities inspected. Results. Expedience of the use in these aims of metrical operations of calculation of complex estimation of the psychophysical state of gettings busy is metrology grounded. Conclusions. Research results confirm expedience of calculation of complex estimation of psychophysical features gettings busy for diagnostics of fitness in the select type of sport and trade prognosis on the subsequent stages of preparation.

  10. Endoscopic and ultrasound diagnostics as contemporary method in diagnostics of dog stomach diseases

    Directory of Open Access Journals (Sweden)

    Krstić Vanja

    2005-01-01

    Full Text Available The visualization of pathological processes in the dog stomach determines a correct diagnosis or differential diagnosis, which presents the basic prerequisite for rational therapy. In addition to the conventional type of clinical examination which covers the taking of anamnestic data, observation of the patient and laboratory tests, there are also certain computerized diagnostic methods (magnetic resonance and scanner which are the most precise and most reliable in the verification of stomach diseases. However, the listed approaches are either insufficiently relevant in making the diagnosis or are too expensive and demanding for the everyday clinical practice. These are the reasons why veterinary medicine today increasingly resorts to the use of other forms of imaging diagnostics, and, as its representatives, the video endoscopic, ultrasound and X-ray examination of the digestive tract.

  11. Structural Reliability Methods

    DEFF Research Database (Denmark)

    Ditlevsen, Ove Dalager; Madsen, H. O.

    The structural reliability methods quantitatively treat the uncertainty of predicting the behaviour and properties of a structure given the uncertain properties of its geometry, materials, and the actions it is supposed to withstand. This book addresses the probabilistic methods for evaluation...... of structural reliability, including the theoretical basis for these methods. Partial safety factor codes under current practice are briefly introduced and discussed. A probabilistic code format for obtaining a formal reliability evaluation system that catches the most essential features of the nature...... of the uncertainties and their interplay is the developed, step-by-step. The concepts presented are illustrated by numerous examples throughout the text....

  12. Bayesian methods in reliability

    Science.gov (United States)

    Sander, P.; Badoux, R.

    1991-11-01

    The present proceedings from a course on Bayesian methods in reliability encompasses Bayesian statistical methods and their computational implementation, models for analyzing censored data from nonrepairable systems, the traits of repairable systems and growth models, the use of expert judgment, and a review of the problem of forecasting software reliability. Specific issues addressed include the use of Bayesian methods to estimate the leak rate of a gas pipeline, approximate analyses under great prior uncertainty, reliability estimation techniques, and a nonhomogeneous Poisson process. Also addressed are the calibration sets and seed variables of expert judgment systems for risk assessment, experimental illustrations of the use of expert judgment for reliability testing, and analyses of the predictive quality of software-reliability growth models such as the Weibull order statistics.

  13. Eating Disorder Diagnostic Scale: Additional Evidence of Reliability and Validity

    Science.gov (United States)

    Stice, Eric; Fisher, Melissa; Martinez, Erin

    2004-01-01

    The authors conducted 4 studies investigating the reliability and validity of the Eating Disorder Diagnostic Scale (HDDS; E. Stice, C. F. Telch, & S. L. Rizvi, 2000), a brief self-report measure for diagnosing anorexia nervosa, bulimia nervosa, and binge eating disorder. Study 1 found that the HDDS showed criterion validity with interview-based…

  14. Publishing nutrition research: validity, reliability, and diagnostic test assessment in nutrition-related research.

    Science.gov (United States)

    Gleason, Philip M; Harris, Jeffrey; Sheean, Patricia M; Boushey, Carol J; Bruemmer, Barbara

    2010-03-01

    This is the sixth in a series of monographs on research design and analysis. The purpose of this article is to describe and discuss several concepts related to the measurement of nutrition-related characteristics and outcomes, including validity, reliability, and diagnostic tests. The article reviews the methodologic issues related to capturing the various aspects of a given nutrition measure's reliability, including test-retest, inter-item, and interobserver or inter-rater reliability. Similarly, it covers content validity, indicators of absolute vs relative validity, and internal vs external validity. With respect to diagnostic assessment, the article summarizes the concepts of sensitivity and specificity. The hope is that dietetics practitioners will be able to both use high-quality measures of nutrition concepts in their research and recognize these measures in research completed by others. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  15. SU-F-E-01: Pitfalls: Reliability and Performance of Diagnostic X-Sources

    Energy Technology Data Exchange (ETDEWEB)

    Behling, R [Philips Medical Systems DMC GmbHHamburg (United States)

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. The author is employee of Royal Philips.

  16. SU-F-E-01: Pitfalls: Reliability and Performance of Diagnostic X-Sources

    International Nuclear Information System (INIS)

    Behling, R

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. The author is employee of Royal Philips

  17. The reliability of the Brazilian version of the Composite International Diagnostic Interview (CIDI 2.1

    Directory of Open Access Journals (Sweden)

    Quintana M.I.

    2004-01-01

    Full Text Available The objective of the present study was to determine the reliability of the Brazilian version of the Composite International Diagnostic Interview 2.1 (CIDI 2.1 in clinical psychiatry. The CIDI 2.1 was translated into Portuguese using WHO guidelines and reliability was studied using the inter-rater reliability method. The study sample consisted of 186 subjects from psychiatric hospitals and clinics, primary care centers and community services. The interviewers consisted of a group of 13 lay and three non-lay interviewers submitted to the CIDI training. The average interview time was 2 h and 30 min. General reliability ranged from kappa 0.50 to 1. For lifetime diagnoses the reliability ranged from kappa 0.77 (Bipolar Affective Disorder to 1 (Substance-Related Disorder, Alcohol-Related Disorder, Eating Disorders. Previous year reliability ranged from kappa 0.66 (Obsessive-Compulsive Disorder to 1 (Dissociative Disorders, Maniac Disorders, Eating Disorders. The poorest reliability rate was found for Mild Depressive Episode (kappa = 0.50 during the previous year. Training proved to be a fundamental factor for maintaining good reliability. Technical knowledge of the questionnaire compensated for the lack of psychiatric knowledge of the lay personnel. Inter-rater reliability was good to excellent for persons in psychiatric practice.

  18. A Review of Frequency Response Analysis Methods for Power Transformer Diagnostics

    Directory of Open Access Journals (Sweden)

    Saleh Alsuhaibani

    2016-10-01

    Full Text Available Power transformers play a critical role in electric power networks. Such transformers can suffer failures due to multiple stresses and aging. Thus, assessment of condition and diagnostic techniques are of great importance for improving power network reliability and service continuity. Several techniques are available to diagnose the faults within the power transformer. Frequency response analysis (FRA method is a powerful technique for diagnosing transformer winding deformation and several other types of problems that are caused during manufacture, transportation, installation and/or service life. This paper provides a comprehensive review on FRA methods and their applications in diagnostics and fault identification for power transformers. The paper discusses theory and applications of FRA methods as well as various issues and challenges faced in the application of this method.

  19. [Methods of statistical analysis in differential diagnostics of the degree of brain glioma anaplasia during preoperative stage].

    Science.gov (United States)

    Glavatskiĭ, A Ia; Guzhovskaia, N V; Lysenko, S N; Kulik, A V

    2005-12-01

    The authors proposed a possible preoperative diagnostics of the degree of supratentorial brain gliom anaplasia using statistical analysis methods. It relies on a complex examination of 934 patients with I-IV degree anaplasias, which had been treated in the Institute of Neurosurgery from 1990 to 2004. The use of statistical analysis methods for differential diagnostics of the degree of brain gliom anaplasia may optimize a diagnostic algorithm, increase reliability of obtained data and in some cases avoid carrying out irrational operative intrusions. Clinically important signs for the use of statistical analysis methods directed to preoperative diagnostics of brain gliom anaplasia have been defined

  20. Development of a diagnostic test set to assess agreement in breast pathology: practical application of the Guidelines for Reporting Reliability and Agreement Studies (GRRAS).

    Science.gov (United States)

    Oster, Natalia V; Carney, Patricia A; Allison, Kimberly H; Weaver, Donald L; Reisch, Lisa M; Longton, Gary; Onega, Tracy; Pepe, Margaret; Geller, Berta M; Nelson, Heidi D; Ross, Tyler R; Tosteson, Aanna N A; Elmore, Joann G

    2013-02-05

    Diagnostic test sets are a valuable research tool that contributes importantly to the validity and reliability of studies that assess agreement in breast pathology. In order to fully understand the strengths and weaknesses of any agreement and reliability study, however, the methods should be fully reported. In this paper we provide a step-by-step description of the methods used to create four complex test sets for a study of diagnostic agreement among pathologists interpreting breast biopsy specimens. We use the newly developed Guidelines for Reporting Reliability and Agreement Studies (GRRAS) as a basis to report these methods. Breast tissue biopsies were selected from the National Cancer Institute-funded Breast Cancer Surveillance Consortium sites. We used a random sampling stratified according to woman's age (40-49 vs. ≥50), parenchymal breast density (low vs. high) and interpretation of the original pathologist. A 3-member panel of expert breast pathologists first independently interpreted each case using five primary diagnostic categories (non-proliferative changes, proliferative changes without atypia, atypical ductal hyperplasia, ductal carcinoma in situ, and invasive carcinoma). When the experts did not unanimously agree on a case diagnosis a modified Delphi method was used to determine the reference standard consensus diagnosis. The final test cases were stratified and randomly assigned into one of four unique test sets. We found GRRAS recommendations to be very useful in reporting diagnostic test set development and recommend inclusion of two additional criteria: 1) characterizing the study population and 2) describing the methods for reference diagnosis, when applicable.

  1. Reliability assessment of fiber optic communication lines depending on external factors and diagnostic errors

    Science.gov (United States)

    Bogachkov, I. V.; Lutchenko, S. S.

    2018-05-01

    The article deals with the method for the assessment of the fiber optic communication lines (FOCL) reliability taking into account the effect of the optical fiber tension, the temperature influence and the built-in diagnostic equipment errors of the first kind. The reliability is assessed in terms of the availability factor using the theory of Markov chains and probabilistic mathematical modeling. To obtain a mathematical model, the following steps are performed: the FOCL state is defined and validated; the state graph and system transitions are described; the system transition of states that occur at a certain point is specified; the real and the observed time of system presence in the considered states are identified. According to the permissible value of the availability factor, it is possible to determine the limiting frequency of FOCL maintenance.

  2. Interobserver Reliability of Four Diagnostic Methods Using Traditional Korean Medicine for Stroke Patients

    Directory of Open Access Journals (Sweden)

    Ju Ah Lee

    2014-01-01

    Full Text Available Objective. The aim of this study is to evaluate the consistency of pattern identification (PI, a set of diagnostic indicators used by traditional Korean medicine (TKM clinicians. Methods. A total of 168 stroke patients who were admitted into oriental medical university hospitals from June 2012 through January 2013 were included in the study. Using the PI indicators, each patient was independently diagnosed by two experts from the same department. Interobserver consistency was assessed by simple percentage agreement as well as by kappa and AC1 statistics. Results. Interobserver agreement on the PI indicators (for all patients was generally high: pulse diagnosis signs (AC1=0.66–0.89; inspection signs (AC1=0.66–0.95; listening/smelling signs (AC1=0.67–0.88; and inquiry signs (AC1=0.62–0.94. Conclusion. In four examinations, there was moderate agreement between the clinicians on the PI indicators. To improve clinician consistency (e.g., in the diagnostic criteria used, it is necessary to analyze the reasons for inconsistency and to improve clinician training.

  3. Reliability of rapid diagnostic tests in diagnosing pregnancy-associated malaria in north-eastern Tanzania

    DEFF Research Database (Denmark)

    Minja, Daniel T.; Schmiegelow, Christentze; Oesterholt, Mayke

    2012-01-01

    dehydrogenase (pLDH) based RDTs (Parascreen™) or HRP-2 only (Paracheck Pf® and ParaHIT®f), microscopy and nested Plasmodium species diagnostic PCR. Results: From a cohort of 924 pregnant women who completed the follow up, complete RDT and microscopy data was available for 5,555 blood samples and of these 442...... (RDTs) could be an ideal diagnostic complement to microscopy, due to their ease of use and adequate sensitivity in detecting even sub-microscopic infections. Polymerase chain reaction (PCR) is even more sensitive, but it is mainly used for research purposes. The accuracy and reliability of RDTs...... in diagnosing PAM was evaluated using microscopy and PCR. Methods: A cohort of pregnant women in north-eastern Tanzania was followed throughout pregnancy for detection of plasmodial infection using venous and placental blood samples evaluated by histidine rich protein 2 (HRP-2) and parasite lactate...

  4. Inter-rater reliability of diagnostic criteria for sacroiliac joint-, disc- and facet joint pain.

    Science.gov (United States)

    van Tilburg, Cornelis W J; Groeneweg, Johannes G; Stronks, Dirk L; Huygen, Frank J P M

    2017-01-01

    Several diagnostic criteria sets are described in the literature to identify low back pain subtypes, but very little is known about the inter-rater reliability of these criteria. We conducted a study to determine the reliability of diagnostic tests that point towards SI joint-, disc- or facet joint pain. Inter-rater reliability study alongside three randomized clinical trials. Multidisciplinary pain center of general hospital. Patients aged 18 or more with medical history and physical examination suggestive of sacroiliac joint-, disc- and facet joint pain on lumbar level. Making use of nowadays most common used diagnostic criteria, a physical examination is taken independently by three physicians (two pain physicians and one orthopedic surgeon). Inter-rater reliability (Kappa (κ) measure of agreement) and significance (p) between raters are presented. Strengths of agreement, indicated with κ values above 0,20, are presented in order of agreement. One hundred patients were included. None of the parameters from the physical investigation had κ values of more than 0.21 (fair) in all pairs of raters. Between two raters (C and D), there was an almost perfect agreement on three parameters, more specifically ``Abnormal sensory and motor examination, hyperactive or diminished reflexes'', ``Sitting exam shows no reflex, motor or sensory signs in the legs'' and ``Straight leg raising (Laségue) negative between 30 and 70 degrees of flexion''. The ``Drop test positive'' parameters had moderate strength of agreement between raters A and D and fair strength between raters A and B. The ``Digital interspinous pressure test positive'' had moderate strength of agreement between raters C and D and fair strength of agreement between raters A and B as well as raters B and C. Three other parameters had a fair strength of agreement between two raters, all other parameters had a slight or poor strength of agreement. Inter-rater reliability, confidence intervals and significance of

  5. Reliability and limitation of various diagnostic methods including nuclear medicine in myocardial disease

    International Nuclear Information System (INIS)

    Tokuyasu, Yoshiki; Kusakabe, Kiyoko; Yamazaki, Toshio

    1981-01-01

    Electrocardiography (ECG), echocardiography, nuclear method, cardiac catheterization, left ventriculography and endomyocardial biopsy (biopsy) were performed in 40 cases of cardiomyopathy (CM), 9 of endocardial fibroelastosis and 19 of specific heart muscle disease, and the usefulness and limitation of each method was comparatively estimated. In CM, various methods including biopsy were performed. The 40 patients were classified into 3 groups, i.e., hypertrophic (17), dilated (20) and non-hypertrophic.non-dilated (3) on the basis of left ventricular ejection fraction and hypertrophy of the ventricular wall. The hypertrophic group was divided into 4 subgroups: 9 septal, 4 apical, 2 posterior and 2 anterior. The nuclear study is useful in assessing the site of the abnormal ventricular thickening, perfusion defect and ventricular function. Echocardiography is most useful in detecting asymmetric septal hypertrophy. The biopsy gives the sole diagnostic clue, especially in non-hypertrophic.non-dilated cardiomyopathy. ECG is useful in all cases but correlation with the site of disproportional hypertrophy was not obtained. (J.P.N.)

  6. Reliability and diagnostic accuracy of history and physical examination for diagnosing glenoid labral tears.

    Science.gov (United States)

    Walsworth, Matthew K; Doukas, William C; Murphy, Kevin P; Mielcarek, Billie J; Michener, Lori A

    2008-01-01

    Glenoid labral tears provide a diagnostic challenge. Combinations of items in the patient history and physical examination will provide stronger diagnostic accuracy to suggest the presence or absence of glenoid labral tear than will individual items. Cohort study (diagnosis); Level of evidence, 1. History and examination findings in patients with shoulder pain (N = 55) were compared with arthroscopic findings to determine diagnostic accuracy and intertester reliability. The intertester reliability of the crank, anterior slide, and active compression tests was 0.20 to 0.24. A combined history of popping or catching and positive crank or anterior slide results yielded specificities of 0.91 and 1.00 and positive likelihood ratios of 3.0 and infinity, respectively. A positive anterior slide result combined with either a positive active compression or crank result yielded specificities of 0.91 and positive likelihood ratio of 2.75 and 3.75, respectively. Requiring only a single positive finding in the combination of popping or catching and the anterior slide or crank yielded sensitivities of 0.82 and 0.89 and negative likelihood ratios of 0.31 and 0.33, respectively. The diagnostic accuracy of individual tests in previous studies is quite variable, which may be explained in part by the modest reliability of these tests. The combination of popping or catching with a positive crank or anterior slide result or a positive anterior slide result with a positive active compression or crank test result suggests the presence of a labral tear. The combined absence of popping or catching and a negative anterior slide or crank result suggests the absence of a labral tear.

  7. Tuberculosis diagnostic methods in buffaloes

    Directory of Open Access Journals (Sweden)

    Gabriela Capriogli Oliveira

    2015-07-01

    Full Text Available The low productivity of buffalo herds and condemnation of carcasses in slaughterhouses due to tuberculosis lesions have resulted in increasing economic losses because these animals cannot be treated and must be destroyed by sanitary slaughter. Tuberculosis is a widely distributed zoonosis that affects the beef supply chain of the Brazilian agribusiness economically and socially. Like cattle, buffaloes are sensitive to Mycobacterium bovis, which is the main causative agent of zoonotic tuberculosis. Tuberculosis in buffaloes has been reported in several countries, including Brazil. In order to control and eradicate this disease among cattle and buffaloes in Brazil, the Ministry of Agriculture, Livestock, and Supply created the National Program for the Control and Eradication of Brucellosis and Tuberculosis with the main objective of finding a significant number of disease-free herds throughout the national territory using reliable methods. This review summarizes the main data on the history of occurrence of M. bovis in Brazilian herds and the diagnostic methods for the disease in buffaloes. Little information is available on buffalo tuberculosis. Due to the increasing population of buffaloes and their economic importance, more studies investigating the occurrence and identification of tuberculosis in this species are clearly needed.

  8. Myasthenia Gravis: Tests and Diagnostic Methods

    Science.gov (United States)

    ... Focus on MG Newsletter MG Quarterly Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events 2018 MG ...

  9. A simple reliability block diagram method for safety integrity verification

    International Nuclear Information System (INIS)

    Guo Haitao; Yang Xianhui

    2007-01-01

    IEC 61508 requires safety integrity verification for safety related systems to be a necessary procedure in safety life cycle. PFD avg must be calculated to verify the safety integrity level (SIL). Since IEC 61508-6 does not give detailed explanations of the definitions and PFD avg calculations for its examples, it is difficult for common reliability or safety engineers to understand when they use the standard as guidance in practice. A method using reliability block diagram is investigated in this study in order to provide a clear and feasible way of PFD avg calculation and help those who take IEC 61508-6 as their guidance. The method finds mean down times (MDTs) of both channel and voted group first and then PFD avg . The calculated results of various voted groups are compared with those in IEC61508 part 6 and Ref. [Zhang T, Long W, Sato Y. Availability of systems with self-diagnostic components-applying Markov model to IEC 61508-6. Reliab Eng System Saf 2003;80(2):133-41]. An interesting outcome can be realized from the comparison. Furthermore, although differences in MDT of voted groups exist between IEC 61508-6 and this paper, PFD avg of voted groups are comparatively close. With detailed description, the method of RBD presented can be applied to the quantitative SIL verification, showing a similarity of the method in IEC 61508-6

  10. An Evaluation Method of Equipment Reliability Configuration Management

    Science.gov (United States)

    Wang, Wei; Feng, Weijia; Zhang, Wei; Li, Yuan

    2018-01-01

    At present, many equipment development companies have been aware of the great significance of reliability of the equipment development. But, due to the lack of effective management evaluation method, it is very difficult for the equipment development company to manage its own reliability work. Evaluation method of equipment reliability configuration management is to determine the reliability management capabilities of equipment development company. Reliability is not only designed, but also managed to achieve. This paper evaluates the reliability management capabilities by reliability configuration capability maturity model(RCM-CMM) evaluation method.

  11. The health preoccupation diagnostic interview: inter-rater reliability of a structured interview for diagnostic assessment of DSM-5 somatic symptom disorder and illness anxiety disorder.

    Science.gov (United States)

    Axelsson, Erland; Andersson, Erik; Ljótsson, Brjánn; Wallhed Finn, Daniel; Hedman, Erik

    2016-06-01

    Somatic symptom disorder (SSD) and illness anxiety disorder (IAD) are two new diagnoses introduced in the DSM-5. There is a need for reliable instruments to facilitate the assessment of these disorders. We therefore developed a structured diagnostic interview, the Health Preoccupation Diagnostic Interview (HPDI), which we hypothesized would reliably differentiate between SSD, IAD, and no diagnosis. Persons with clinically significant health anxiety (n = 52) and healthy controls (n = 52) were interviewed using the HPDI. Diagnoses were then compared with those made by an independent assessor, who listened to audio recordings of the interviews. Ratings generally indicated moderate to almost perfect inter-rater agreement, as illustrated by an overall Cohen's κ of .85. Disagreements primarily concerned (a) the severity of somatic symptoms, (b) the differential diagnosis of panic disorder, and (c) SSD specifiers. We conclude that the HPDI can be used to reliably diagnose DSM-5 SSD and IAD.

  12. An accurate and efficient reliability-based design optimization using the second order reliability method and improved stability transformation method

    Science.gov (United States)

    Meng, Zeng; Yang, Dixiong; Zhou, Huanlin; Yu, Bo

    2018-05-01

    The first order reliability method has been extensively adopted for reliability-based design optimization (RBDO), but it shows inaccuracy in calculating the failure probability with highly nonlinear performance functions. Thus, the second order reliability method is required to evaluate the reliability accurately. However, its application for RBDO is quite challenge owing to the expensive computational cost incurred by the repeated reliability evaluation and Hessian calculation of probabilistic constraints. In this article, a new improved stability transformation method is proposed to search the most probable point efficiently, and the Hessian matrix is calculated by the symmetric rank-one update. The computational capability of the proposed method is illustrated and compared to the existing RBDO approaches through three mathematical and two engineering examples. The comparison results indicate that the proposed method is very efficient and accurate, providing an alternative tool for RBDO of engineering structures.

  13. Laboratory diagnostic methods, system of quality and validation

    Directory of Open Access Journals (Sweden)

    Ašanin Ružica

    2005-01-01

    Full Text Available It is known that laboratory investigations secure safe and reliable results that provide a final confirmation of the quality of work. Ideas, planning, knowledge, skills, experience, and environment, along with good laboratory practice, quality control and reliability of quality, make the area of biological investigations very complex. In recent years, quality control, including the control of work in the laboratory, is based on international standards and is used at that level. The implementation of widely recognized international standards, such as the International Standard ISO/IEC 17025 (1 and the implementing of the quality system series ISO/IEC 9000 (2 have become the imperative on the grounds of which laboratories have a formal, visible and corresponding system of quality. The diagnostic methods that are used must constantly yield results which identify the animal as positive or negative, and the precise status of the animal is determined with a predefined degree of statistical significance. Methods applied on a selected population reduce the risk of obtaining falsely positive or falsely negative results. A condition for this are well conceived and documented methods, with the application of the corresponding reagents, and work with professional and skilled staff. This process requires also a consistent implementation of the most rigorous experimental plans, epidemiological and statistical data and estimations, with constant monitoring of the validity of the applied methods. Such an approach is necessary in order to cut down the number of misconceptions and accidental mistakes, for a referent population of animals on which the validity of a method is tested. Once a valid method is included in daily routine investigations, it is necessary to apply constant monitoring for the purpose of internal quality control, in order adequately to evaluate its reproducibility and reliability. Consequently, it is necessary at least twice yearly to conduct

  14. Multi-immunoreaction-based dual-color capillary electrophoresis for enhanced diagnostic reliability of thyroid gland disease.

    Science.gov (United States)

    Woo, Nain; Kim, Su-Kang; Kang, Seong Ho

    2017-08-04

    Thyroid-stimulating hormone (TSH) secretion plays a critical role in regulating thyroid gland function and circulating thyroid hormones (i.e., thyroxine (T4) and triiodothyronine (T3)). A novel multi-immunoreaction-based dual-color capillary electrophoresis (CE) technique was investigated in this study to assess its reliability in diagnosing thyroid gland disease via simultaneous detection of TSH, T3, and T4 in a single run of CE. Compared to the conventional immunoreaction technique, multi-immunoreaction of biotinylated streptavidin antibodies increased the selectivity and sensitivity for individual hormones in human blood samples. Dual-color laser-induced fluorescence (LIF) detection-based CE performed in a running buffer of 25mM Na 2 B 4 O 7 -NaOH (pH 9.3) allowed for fast, simultaneous quantitative analysis of three target thyroid hormones using different excited wavelengths within 3.2min. This process had excellent sensitivity and detection limits of 0.05-5.32 fM. The results showed 1000-100,000 times higher detection sensitivity than previous methods. Method validation with enzyme linked immunosorbent assay for application with human blood samples showed that the CE method was not significantly different at the 98% confidence level. Therefore, the developed CE-LIF method has the advantages of high detection sensitivity, faster analysis time, and smaller sample amount compared to the conventional methods The combined multi-immunoreaction and dual-color CE-LIF method should have increased diagnostic reliability for thyroid gland disease compared to conventional methods based on its highly sensitive detection of thyroid hormones using a single injection and high-throughput screening. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Transcranial Doppler sonography as diagnostic method

    Directory of Open Access Journals (Sweden)

    Jasminka Đelilović-Vranić

    2002-02-01

    Full Text Available Having in mind the fact that cerebrovascular disease (CVB takes today in medicine, in spite of diagnostic and therapeutic modernisation, the third place of mortality causes in the world (behind cordial and malignant diseases, but in front of depressions, and the second place of invalidity cause (right after trauma as well as the second place of dementia cause (after Alzheimer disease, it urges primary prophylaxis. Developing countries, but before all countries of East and Middle Europe, where is our country, are highly risked areas where CV disease has trend of incidence and total frequency increase. In the neighbouring Croatia today CV disease is at the first place of mortality causes. In the world today 5 million people annually suffer CV disease, in Europe about 700.000, but frequency of suffering on Balkan is about 5 prom. Age of CV disease effecting unfortunately moved towards young age, and today 49% of effected by CV disease are of 46 to 59 years of age. Early detection and treatment of risk factors (before hypertension, smoking, diabetes mellitus, hyperlipidaemia, stress and physical non-activities are the first aspect of CV disease prophylaxis. Together with this aspect of primary prophylaxis is early detection of complications of mentioned risk factors on the walls of blood vessels, before all changing in sense of arteriosclerosis, with consequence of disorder of cerebral haemodynamics. With that objective - verification of circulator and total haemodynamic disorders, there is obvious disclose of non-invasive diagnostic methods, and one of them is Transcranial Doppler Sonography(TCD. TCD is method comfortable for patient, reliable and rather precise, dynamic, and can be repeated several times, without side effects and in comparison with others rather cheap.

  16. Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol

    International Nuclear Information System (INIS)

    Cura del, J. L.; Oleaga, L.; Grande, D.; Vela, A. C.; Ibanez, A. M.

    2001-01-01

    To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, there were fewer complications and a shorter hospital stay in the first group. Among men, however, the rate of negative appendectomy was lower in the control group. The cost of using ultrasound and CT in the management of appendicitis was only slightly higher than that of the control group. Although ultrasound and CT are not necessary in cases in which the probability of appendicitis is low or in men presenting clear clinical evidence, the use of these techniques is indicated in the remaining cases in which appendicitis is suspected. In children, ultrasound is the technique of choice. In all other patients, if negative results are obtained with one of the two techniques, the other should be performed. (Author) 49 refs

  17. HUMAN RELIABILITY ANALYSIS DENGAN PENDEKATAN COGNITIVE RELIABILITY AND ERROR ANALYSIS METHOD (CREAM

    Directory of Open Access Journals (Sweden)

    Zahirah Alifia Maulida

    2015-01-01

    Full Text Available Kecelakaan kerja pada bidang grinding dan welding menempati urutan tertinggi selama lima tahun terakhir di PT. X. Kecelakaan ini disebabkan oleh human error. Human error terjadi karena pengaruh lingkungan kerja fisik dan non fisik.Penelitian kali menggunakan skenario untuk memprediksi serta mengurangi kemungkinan terjadinya error pada manusia dengan pendekatan CREAM (Cognitive Reliability and Error Analysis Method. CREAM adalah salah satu metode human reliability analysis yang berfungsi untuk mendapatkan nilai Cognitive Failure Probability (CFP yang dapat dilakukan dengan dua cara yaitu basic method dan extended method. Pada basic method hanya akan didapatkan nilai failure probabailty secara umum, sedangkan untuk extended method akan didapatkan CFP untuk setiap task. Hasil penelitian menunjukkan faktor- faktor yang mempengaruhi timbulnya error pada pekerjaan grinding dan welding adalah kecukupan organisasi, kecukupan dari Man Machine Interface (MMI & dukungan operasional, ketersediaan prosedur/ perencanaan, serta kecukupan pelatihan dan pengalaman. Aspek kognitif pada pekerjaan grinding yang memiliki nilai error paling tinggi adalah planning dengan nilai CFP 0.3 dan pada pekerjaan welding yaitu aspek kognitif execution dengan nilai CFP 0.18. Sebagai upaya untuk mengurangi nilai error kognitif pada pekerjaan grinding dan welding rekomendasi yang diberikan adalah memberikan training secara rutin, work instrucstion yang lebih rinci dan memberikan sosialisasi alat. Kata kunci: CREAM (cognitive reliability and error analysis method, HRA (human reliability analysis, cognitive error Abstract The accidents in grinding and welding sectors were the highest cases over the last five years in PT. X and it caused by human error. Human error occurs due to the influence of working environment both physically and non-physically. This study will implement an approaching scenario called CREAM (Cognitive Reliability and Error Analysis Method. CREAM is one of human

  18. A Method of Nuclear Software Reliability Estimation

    International Nuclear Information System (INIS)

    Park, Gee Yong; Eom, Heung Seop; Cheon, Se Woo; Jang, Seung Cheol

    2011-01-01

    A method on estimating software reliability for nuclear safety software is proposed. This method is based on the software reliability growth model (SRGM) where the behavior of software failure is assumed to follow the non-homogeneous Poisson process. Several modeling schemes are presented in order to estimate and predict more precisely the number of software defects based on a few of software failure data. The Bayesian statistical inference is employed to estimate the model parameters by incorporating the software test cases into the model. It is identified that this method is capable of accurately estimating the remaining number of software defects which are on-demand type directly affecting safety trip functions. The software reliability can be estimated from a model equation and one method of obtaining the software reliability is proposed

  19. A COMPUTERIZED DIAGNOSTIC COMPLEX FOR RELIABILITY TESTING OF ELECTRIC MACHINES

    Directory of Open Access Journals (Sweden)

    O.О. Somka

    2015-06-01

    Full Text Available Purpose. To develop a diagnostic complex meeting the criteria and requirements for carrying out accelerated reliability test and realizing the basic modes of electric machines operation and performance of the posed problems necessary in the process of such test. Methodology. To determine and forecast the indices of electric machines reliability in accordance with the statistic data of repair plants we have conditionally divided them into structural parts that are most likely to fail. We have preliminarily assessed the state of each of these parts, which includes revelation of faults and deviations of technical and geometric parameters. We have determined the analyzed electric machine controlled parameters used for assessment of quantitative characteristics of reliability of these parts and electric machines on the whole. Results. As a result of the research, we have substantiated the structure of a computerized complex for electric machines reliability test. It allows us to change thermal and vibration actions without violation of the physics of the processes of aging and wearing of the basic structural parts and elements material. The above mentioned makes it possible to considerably reduce time spent on carrying out electric machines reliability tests and improve trustworthiness of the data obtained as a result of their performance. Originality. A special feature of determination of the controlled parameters consists in removal of vibration components in the idle mode and after disconnection of the analyzed electric machine from the power supply with the aim of singling out the vibration electromagnetic component, fixing the degree of sparking and bend of the shaft by means of phototechnique and local determination of structural parts temperature provided by corresponding location of thermal sensors. Practical value. We have offered a scheme of location of thermal and vibration sensors, which allows improvement of parameters measuring accuracy

  20. Diagnostic planning in JT-60 project

    International Nuclear Information System (INIS)

    Matoba, Tohru; Suzuki, Yasuo; Funahashi, Akimasa; Itagaki, Tokiyoshi

    1977-08-01

    The diagnostic plans of JT-60 were made along with design of the main machine. Basic requirements of the diagnostic program are (1) multiple measurement of respective plasma parameters, (2) efficient usage of the discharge, (3) capable data acquisition system, (4) high reliability of the diagnostic equipments, and (5) systematic development of new diagnostic techniques. Dimensions of the diagnostic ports were determined in detailed design of the vacuum vessel, anticipating the possible diagnostic methods. The proposed diagnostic systems and the plans are shown in table and figures respectively. Problems in the diagnostics are also described. (auth.)

  1. Evaluation of structural reliability using simulation methods

    Directory of Open Access Journals (Sweden)

    Baballëku Markel

    2015-01-01

    Full Text Available Eurocode describes the 'index of reliability' as a measure of structural reliability, related to the 'probability of failure'. This paper is focused on the assessment of this index for a reinforced concrete bridge pier. It is rare to explicitly use reliability concepts for design of structures, but the problems of structural engineering are better known through them. Some of the main methods for the estimation of the probability of failure are the exact analytical integration, numerical integration, approximate analytical methods and simulation methods. Monte Carlo Simulation is used in this paper, because it offers a very good tool for the estimation of probability in multivariate functions. Complicated probability and statistics problems are solved through computer aided simulations of a large number of tests. The procedures of structural reliability assessment for the bridge pier and the comparison with the partial factor method of the Eurocodes have been demonstrated in this paper.

  2. Test-retest reliability of the proposed DSM-5 eating disorder diagnostic criteria

    Science.gov (United States)

    Sysko, Robyn; Roberto, Christina A.; Barnes, Rachel D.; Grilo, Carlos M.; Attia, Evelyn; Walsh, B. Timothy

    2012-01-01

    The proposed DSM-5 classification scheme for eating disorders includes both major and minor changes to the existing DSM-IV diagnostic criteria. It is not known what effect these modifications will have on the ability to make reliable diagnoses. Two studies were conducted to evaluate the short-term test-retest reliability of the proposed DSM-5 eating disorder diagnoses: anorexia nervosa, bulimia nervosa, binge eating disorder, and feeding and eating conditions not elsewhere classified. Participants completed two independent telephone interviews with research assessors (n=70 Study 1; n=55 Study 2). Fair to substantial agreements (κ= 0.80 and 0.54) were observed across eating disorder diagnoses in Study 1 and Study 2, respectively. Acceptable rates of agreement were identified for the individual eating disorder diagnoses, including DSM-5 anorexia nervosa (κ’s of 0.81 to 0.97), bulimia nervosa (κ=0.84), binge eating disorder (κ’s of 0.75 and 0.61), and feeding and eating disorders not elsewhere classified (κ’s of 0.70 and 0.46). Further, improved short-term test-retest reliability was noted when using the DSM-5, in comparison to DSM-IV, criteria for binge eating disorder. Thus, these studies found that trained interviewers can reliably diagnose eating disorders using the proposed DSM-5 criteria; however, additional data from general practice settings and community samples are needed. PMID:22401974

  3. Efficient diagnostic methods for nuclear power plant monitoring

    International Nuclear Information System (INIS)

    Sunder, R.

    1997-01-01

    There are systems for operational monitoring of vibrations, valves, solid-borne sound, leaks, and embrittlement. The paper focuses on vibration monitoring of pressurized components and systems in PWRs and BWRs. Other than with conventional systems, the task is not to globally monitor the vibration level, but the frequency-selective information is used as a sensitive information source, the level of vibrations being of secondary significance. The essential feature therefore is the comprehensive and selective scanning of individual frequency components in the recorded vibration spectra, which in some cases can be less than a millesimal millimeter. Upon identification of the various vibration components - from so-called baseline analyses using correlation methods - vibration analysis is done by only one step, comparing a defined reference state with the actual vibration state of the monitored system component. In the event of detected deviations, information on the causes of vibrations - essentially component-related structural resonances - will give the relevant cause-effect relationship. The paper uses some practical examples to illustrate that reliable diagnoses are achieved by the above-mentioned frequency-selective technique. It is important, however, to carry out a sufficiently reliable statistical verification of diagnostic data by means of vibration trending. This is ensured with the digital systems and their high data acquisition rates. (orig./CB) [de

  4. Study for the design method of multi-agent diagnostic system to improve diagnostic performance for similar abnormality

    International Nuclear Information System (INIS)

    Minowa, Hirotsugu; Gofuku, Akio

    2014-01-01

    Accidents on industrial plants cause large loss on human, economic, social credibility. In recent, studies of diagnostic methods using techniques of machine learning such as support vector machine is expected to detect the occurrence of abnormality in a plant early and correctly. There were reported that these diagnostic machines has high accuracy to diagnose the operating state of industrial plant under mono abnormality occurrence. But the each diagnostic machine on the multi-agent diagnostic system may misdiagnose similar abnormalities as a same abnormality if abnormalities to diagnose increases. That causes that a single diagnostic machine may show higher diagnostic performance than one of multi-agent diagnostic system because decision-making considering with misdiagnosis is difficult. Therefore, we study the design method for multi-agent diagnostic system to diagnose similar abnormality correctly. This method aimed to realize automatic generation of diagnostic system where the generation process and location of diagnostic machines are optimized to diagnose correctly the similar abnormalities which are evaluated from the similarity of process signals by statistical method. This paper explains our design method and reports the result evaluated our method applied to the process data of the fast-breeder reactor Monju

  5. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  6. Validation of Land Cover Products Using Reliability Evaluation Methods

    Directory of Open Access Journals (Sweden)

    Wenzhong Shi

    2015-06-01

    Full Text Available Validation of land cover products is a fundamental task prior to data applications. Current validation schemes and methods are, however, suited only for assessing classification accuracy and disregard the reliability of land cover products. The reliability evaluation of land cover products should be undertaken to provide reliable land cover information. In addition, the lack of high-quality reference data often constrains validation and affects the reliability results of land cover products. This study proposes a validation schema to evaluate the reliability of land cover products, including two methods, namely, result reliability evaluation and process reliability evaluation. Result reliability evaluation computes the reliability of land cover products using seven reliability indicators. Process reliability evaluation analyzes the reliability propagation in the data production process to obtain the reliability of land cover products. Fuzzy fault tree analysis is introduced and improved in the reliability analysis of a data production process. Research results show that the proposed reliability evaluation scheme is reasonable and can be applied to validate land cover products. Through the analysis of the seven indicators of result reliability evaluation, more information on land cover can be obtained for strategic decision-making and planning, compared with traditional accuracy assessment methods. Process reliability evaluation without the need for reference data can facilitate the validation and reflect the change trends of reliabilities to some extent.

  7. Diagnostic methods for insect sting allergy.

    Science.gov (United States)

    Hamilton, Robert G

    2004-08-01

    This review overviews advances from mid-2002 to the present in the validation and performance methods used in the diagnosis of Hymenoptera venom-induced immediate-type hypersensitivity. The general diagnostic algorithm for insect sting allergy is initially discussed with an examination of the AAAAI's 2003 revised practice parameter guidelines. Changes as a result of a greater recognition of skin test negative systemic reactors include repeat analysis of all testing and acceptance of serology as a complementary diagnostic test to the skin test. Original data examining concordance of venom-specific IgE results produced by the second-generation Pharmacia CAP System with the Johns Hopkins University radioallergosorbent test are presented. Diagnostic performance of honeybee venom-specific IgE assays used in clinical laboratories in North America is discussed using data from the Diagnostic Allergy Proficiency Survey conducted by the College of American Pathologists. Validity of venom-specific IgE antibody in postmortem blood specimens is demonstrated. The utility of alternative in-vivo (provocation) and in-vitro (basophil-based) diagnostic testing methods is critiqued. This overview supports the following conclusions. Improved practice parameter guidelines include serology and skin test as complementary in supporting a positive clinical history during the diagnostic process. Data are provided which support the analytical performance of commercially available venom-specific IgE antibody serology-based assays. Intentional sting challenge in-vivo provocation, in-vitro basophil flow cytometry (CD63, CD203c) based assays, and in-vitro basophil histamine and sulfidoleukotriene release assays have their utility in the study of difficult diagnostic cases, but their use will remain as supplementary, secondary diagnostic tests.

  8. Application of reliability methods in Ontario Hydro

    International Nuclear Information System (INIS)

    Jeppesen, R.; Ravishankar, T.J.

    1985-01-01

    Ontario Hydro have established a reliability program in support of its substantial nuclear program. Application of the reliability program to achieve both production and safety goals is described. The value of such a reliability program is evident in the record of Ontario Hydro's operating nuclear stations. The factors which have contributed to the success of the reliability program are identified as line management's commitment to reliability; selective and judicious application of reliability methods; establishing performance goals and monitoring the in-service performance; and collection, distribution, review and utilization of performance information to facilitate cost-effective achievement of goals and improvements. (orig.)

  9. Water chemistry data acquisition, processing, evaluation and diagnostic systems in Light Water Reactors: Future improvement of plant reliability and safety

    International Nuclear Information System (INIS)

    Uchida, S.; Takiguchi, H.; Ishigure, K.

    2006-01-01

    Data acquisition, processing and evaluation systems have been applied in major Japanese PWRs and BWRs to provide (1) reliable and quick data acquisition with manpower savings in plant chemical laboratories and (2) smooth and reliable information transfer among chemists, plant operators, and supervisors. Data acquisition systems in plants consist of automatic and semi-automatic instruments for chemical analyses, e. g., X-ray fluorescence analysis and ion chromatography, while data processing systems consist of PC base-sub-systems, e.g., data storage, reliability evaluation, clear display, and document preparation for understanding the plant own water chemistry trends. Precise and reliable evaluations of water chemistry data are required in order to improve plant reliability and safety. For this, quality assurance of the water chemistry data acquisition system is needed. At the same time, theoretical models are being applied to bridge the gaps between measured water chemistry data and the information desired to understand the interaction of materials and cooling water in plants. Major models which have already been applied for plant evaluation are: (1) water radiolysis models for BWRs and PWRs; (2) crevice radiolysis model for SCC in BWRs; and (3) crevice pH model for SG tubing in PWRs. High temperature water chemistry sensors and automatic plant diagnostic systems have been applied in only restricted areas. ECP sensors are gaining popularity as tools to determine the effects of hydrogen injection in BWR systems. Automatic plant diagnostic systems based on artificial intelligence will be more popular after having sufficient experience with off line diagnostic systems. (author)

  10. Analysis of Vibration Diagnostics Methods for Induction Motors

    Directory of Open Access Journals (Sweden)

    A. P. Kalinov

    2012-01-01

    Full Text Available The paper presents an analysis of existing vibration diagnostics methods. In order to evaluate an efficiency of method application the following criteria have been proposed: volume of input data required for establishing diagnosis, data content, software and hardware level, execution time for vibration diagnostics. According to the mentioned criteria a classification of vibration diagnostics methods for determination of their advantages and disadvantages, search for their development and improvement has been presented in paper. The paper contains a comparative estimation of methods in accordance with the proposed  criteria. According to this estimation the most efficient methods are a spectral analysis and spectral analysis of the vibration signal envelope.

  11. Reliability of a Skin Diagnostic Device in Assessing Hydration and Erythema.

    Science.gov (United States)

    Huimin, Koh; Rowledge, Alexandra M; Borzdynski, Caroline J; Miller, Charne; Frescos, Nicoletta; McKenzie, Gayle; Perry, Elizabeth; McGuiness, William

    2017-10-01

    To examine the reliability of a skin diagnostic device, the SD202 (Courage+Khazaka GmBH, Cologne, Germany), in assessing hydration and erythema of periwound skin and pressure injury-prone areas. Intrarater reliabilities from 3 cross-sectional and prospective studies are reported. Patients attending an outpatient, nurse-led wound dressing clinic (n = 16), a podiatrist-led high-risk foot clinic (n = 17), and residents (n = 38) at a single residential aged-care facility. Skin hydration and erythema levels assessed using the SD202. High internal consistency was maintained for consecutive skin hydration and erythema measures at a single point on the venous leg ulcer periwound (α > .996 and α > .970 for hydration and erythema, respectively) and for the pressure-prone areas of the sacrum (α > .916), right (α > .994) and left (α > .967) ischium, right (α > .989) and left (α > .916) trochanter, right (α > .985) and left (α > .992) calcaneus, and right (α > .991) and left (α > .990) lateral malleolus. High consistency was also found for the measures obtained at 4 different locations around the periwound for the venous leg ulcer (α > .935 and α > .870 for hydration and erythema, respectively). In diabetic foot ulcer assessment, acceptable internal consistency of hydration measures around the periwound was observed (α > .634). Internal consistency of erythema measures was variable, ranging from low to high reliability, particularly among predebridement measures. Using the protocols outlined in this study, the SD202 demonstrates high reliability for assessing skin hydration and erythema levels. It is possible that the SD202 can be used in clinical practice as an appropriate tool for skin hydration and erythema assessment.

  12. A new method of diagnostics for the magnetospheric plasma

    International Nuclear Information System (INIS)

    Etcheto, Jacqueline; Petit, Michel

    1977-01-01

    A new diagnostic technique for magnetospheric plasma, based on in situ excitation of the plasma resonances, has been used for the first time on board the Geos satellite. The preliminary results are very gratifying: electron density and magnetic field intensity are derived reliably and accurately from the resonances observed; hopefully, temperature and electric field will be deduced from the data as well [fr

  13. [CONTEMPORARY MOLECULAR-GENETIC METHODS USED FOR ETIOLOGIC DIAGNOSTICS OF SEPSIS].

    Science.gov (United States)

    Gavrilov, S N; Skachkova, T S; Shipulina, O Yu; Savochkina, Yu A; Shipulin, G A; Maleev, V V

    2016-01-01

    Etiologic diagnostics of sepsis is one of the most difficult problems of contemporary medicine due to a wide variety of sepsis causative agents, many of which are components of normal human microflora. Disadvantages of contemporary "golden standard" of microbiologic diagnostics of sepsis etiology by seeding of blood for sterility are duration of cultivation, limitation in detection of non-cultivable forms of microorganisms, significant effect of preliminary empiric antibiotics therapy on results of the analysis. Methods of molecular diagnostics that are being actively developed and integrated during the last decade are deprived of these disadvantages. Main contemporary methods of molecular-biological diagnostics are examined in the review, actualdata on their diagnostic characteristic are provided. Special attention is given to methods of PCR-diagnostics, including novel Russian developments. Methods of nucleic acid hybridization and proteomic analysis are examined in comparative aspect. Evaluation of application and perspectives of development of methods of molecular diagnostics of sepsis is given.

  14. DIAGNOSTIC METHODS IN BREAST CANCER DETECTION

    Directory of Open Access Journals (Sweden)

    Kristijana Hertl

    2018-02-01

    Full Text Available Background. In the world as well as in Slovenia, breast cancer is the most frequent female cancer. Due to its high incidence, it appears to be a serious health and economic problem. Content. Among other, tumour size at diagnosis, is an important prognostic factors of the course of the disease. The probability of axillary lymph node involvement as well as distant metastases is greater in larger tumours. This is the reason that encouraged the development of various diagnostic methods for early detection of small, clinically non-palpable breast tumours. Mammography, however, remains the »golden standard« of early breast cancer detection. It is the basic diagnostic method applied in all symptomatic women over 35 years of age and in asymptomatic women over 40 years of age. Ultrasonography (US, additional projections, magnetic resonance imaging (MRI and ductography are regarded as complementary diagnostic breast imaging techniques in addition to mammography. The detected changes in the breast can be further confirmed by US-, MR-guided or stereotactic biopsy. If necessary, surgical biopsy and the excision of a tissue sample, after wire or isotope localisation of the nonpalpable lesion, can be performed. Conclusions. Any of the above mentioned diagnostic methods has advantages as well as drawbacks and only detailed knowledge and understanding of each of them may assure the best option.

  15. The engineering of JET diagnostics

    International Nuclear Information System (INIS)

    Walker, C.I.; Dillon, S.F.; Hammond, N.P.; Hancock, C.J.; Lam, N.; McCarron, E.J.; Prior, P.C.S.; Reid, J.; Sanders, S.; Tellier, X.; Tiscornia, A.J.; Whitfield, G.A.H.; Wilson, C.H.; Wilson, D.J.

    1995-01-01

    There are some 62 identifiably different diagnostic systems on JET. 22 were installed new at the last, Pumped Divertor, shutdown and a further 22 which were modified, upgraded or repositioned. This paper describes some of the engineering aspects peculiar to the renewed diagnostic systems, reviews their construction and installation and gives an overview of the design of presently installed diagnostic equipment at the Torus. Examples are considered that illustrate the breakdown into a categorisation based on their installation method. This is useful for discussion of many of the associated engineering problems of method and quality control of manufacture, vulnerability, access for installation and maintenance and ultimately system safety and reliability. The function and measured plasma parameter of specific diagnostics is covered in other papers and is not attempted here, neither is a full catalogue of Diagnostics on JET. (orig.)

  16. Aircraft Engine Gas Path Diagnostic Methods: Public Benchmarking Results

    Science.gov (United States)

    Simon, Donald L.; Borguet, Sebastien; Leonard, Olivier; Zhang, Xiaodong (Frank)

    2013-01-01

    Recent technology reviews have identified the need for objective assessments of aircraft engine health management (EHM) technologies. To help address this issue, a gas path diagnostic benchmark problem has been created and made publicly available. This software tool, referred to as the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES), has been constructed based on feedback provided by the aircraft EHM community. It provides a standard benchmark problem enabling users to develop, evaluate and compare diagnostic methods. This paper will present an overview of ProDiMES along with a description of four gas path diagnostic methods developed and applied to the problem. These methods, which include analytical and empirical diagnostic techniques, will be described and associated blind-test-case metric results will be presented and compared. Lessons learned along with recommendations for improving the public benchmarking processes will also be presented and discussed.

  17. Nailfold capillaroscopy as a diagnostic and prognostic method in rosacea.

    Science.gov (United States)

    Fonseca, Gabriela Poglia; Brenner, Fabiane Mulinari; Muller, Carolina de Souza; Wojcik, Adma Lima

    2011-01-01

    There is no appropriate and reliable method of evaluating and monitoring severity in rosacea. To determine the importance of nailfold capillaroscopy as a diagnostic and prognostic method for patients with rosacea. A cross-sectional study where eight patients with rosacea and 8 control subjects were submitted to nailfold capillaroscopy from May to July 2009. We collected clinical data related to gender, age, skin phototype, and rosacea stage according to Plewig and Kligman classification and the classification of the National Rosacea Society. Additionally, we evaluated the progression of the disease and treatment therapies previously used. The majority of the patients evaluated (6 out of 8 patients) had rosacea subtype I (vascular) or erythematotelangiectatic rosacea. The mean duration of the disorder was 5.96 years, and 87.5% of the patients were under treatment with topical metronidazole. Nailfold cappilaroscopy showed that evidence of devascularization was absent in both groups. Nailfold capillaroscopy presents a nonspecific pattern and does not seem to help in the diagnosis or prognosis of rosacea.

  18. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, Rick [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hampton, Nigel [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Perkel, Josh [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hernandez, JC [Univ. de Los Andes, Merida (Venezuela); Elledge, Stacy [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); del Valle, Yamille [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Grimaldo, Jose [Georgia Inst. of Technology, Atlanta, GA (United States). School of Electrical and Computer Engineering; Deku, Kodzo [Georgia Inst. of Technology, Atlanta, GA (United States). George W. Woodruff School of Mechanical Engineering

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach as a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.

  19. Reliability of salivary testosterone measurements in diagnosis of Polycystic Ovarian Syndrome

    Directory of Open Access Journals (Sweden)

    Omnia Youssef

    2010-07-01

    Conclusion: Determination of salivary testosterone is a reliable method to detect changes in the concentration of available biologically active testosterone in the serum. Salivary testosterone provides a sensitive, simple, reliable, non-invasive and uncomplicated diagnostic approach for PCOS.

  20. Characterization and Diagnostics for Photovoltaic Modules and Arrays

    DEFF Research Database (Denmark)

    Spataru, Sergiu

    part of this work were developed based on two well-known module characterization techniques, namely current-voltage (I-V) characterization, and electroluminescence imaging. he I-V based module diagnostic methods were developed by combining the strengths of light I-V and dark I-V characterization......, characterization and diagnostic methods are increasingly important in identifying and understanding the failures and degradation modes affecting PV modules and arrays, as well as developing relevant tools and tests for assessing the reliability and lifetime of PV modules. This thesis investigates diagnostic...... methods for characterizing and detecting degradation modes in crystalline silicon photovoltaic modules and arrays, and is structured into two parts. The first part of this work is focused on developing PV module characterization and diagnostic methods for use in module diagnostics and failure...

  1. A novel reliability evaluation method for large engineering systems

    Directory of Open Access Journals (Sweden)

    Reda Farag

    2016-06-01

    Full Text Available A novel reliability evaluation method for large nonlinear engineering systems excited by dynamic loading applied in time domain is presented. For this class of problems, the performance functions are expected to be function of time and implicit in nature. Available first- or second-order reliability method (FORM/SORM will be challenging to estimate reliability of such systems. Because of its inefficiency, the classical Monte Carlo simulation (MCS method also cannot be used for large nonlinear dynamic systems. In the proposed approach, only tens instead of hundreds or thousands of deterministic evaluations at intelligently selected points are used to extract the reliability information. A hybrid approach, consisting of the stochastic finite element method (SFEM developed by the author and his research team using FORM, response surface method (RSM, an interpolation scheme, and advanced factorial schemes, is proposed. The method is clarified with the help of several numerical examples.

  2. Tracking Progress in Improving Diagnosis: A Framework for Defining Undesirable Diagnostic Events.

    Science.gov (United States)

    Olson, Andrew P J; Graber, Mark L; Singh, Hardeep

    2018-01-29

    Diagnostic error is a prevalent, harmful, and costly phenomenon. Multiple national health care and governmental organizations have recently identified the need to improve diagnostic safety as a high priority. A major barrier, however, is the lack of standardized, reliable methods for measuring diagnostic safety. Given the absence of reliable and valid measures for diagnostic errors, we need methods to help establish some type of baseline diagnostic performance across health systems, as well as to enable researchers and health systems to determine the impact of interventions for improving the diagnostic process. Multiple approaches have been suggested but none widely adopted. We propose a new framework for identifying "undesirable diagnostic events" (UDEs) that health systems, professional organizations, and researchers could further define and develop to enable standardized measurement and reporting related to diagnostic safety. We propose an outline for UDEs that identifies both conditions prone to diagnostic error and the contexts of care in which these errors are likely to occur. Refinement and adoption of this framework across health systems can facilitate standardized measurement and reporting of diagnostic safety.

  3. Structural reliability calculation method based on the dual neural network and direct integration method.

    Science.gov (United States)

    Li, Haibin; He, Yun; Nie, Xiaobo

    2018-01-01

    Structural reliability analysis under uncertainty is paid wide attention by engineers and scholars due to reflecting the structural characteristics and the bearing actual situation. The direct integration method, started from the definition of reliability theory, is easy to be understood, but there are still mathematics difficulties in the calculation of multiple integrals. Therefore, a dual neural network method is proposed for calculating multiple integrals in this paper. Dual neural network consists of two neural networks. The neural network A is used to learn the integrand function, and the neural network B is used to simulate the original function. According to the derivative relationships between the network output and the network input, the neural network B is derived from the neural network A. On this basis, the performance function of normalization is employed in the proposed method to overcome the difficulty of multiple integrations and to improve the accuracy for reliability calculations. The comparisons between the proposed method and Monte Carlo simulation method, Hasofer-Lind method, the mean value first-order second moment method have demonstrated that the proposed method is an efficient and accurate reliability method for structural reliability problems.

  4. Structural hybrid reliability index and its convergent solving method based on random–fuzzy–interval reliability model

    OpenAIRE

    Hai An; Ling Zhou; Hui Sun

    2016-01-01

    Aiming to resolve the problems of a variety of uncertainty variables that coexist in the engineering structure reliability analysis, a new hybrid reliability index to evaluate structural hybrid reliability, based on the random–fuzzy–interval model, is proposed in this article. The convergent solving method is also presented. First, the truncated probability reliability model, the fuzzy random reliability model, and the non-probabilistic interval reliability model are introduced. Then, the new...

  5. Self-adapted thermocouple-diagnostic complex

    International Nuclear Information System (INIS)

    Alekseev, S.V.; Grankovskij, K.Eh.; Olejnikov, P.P.; Prijmak, S.V.; Shikalov, V.F.

    2003-01-01

    A self-adapted thermocouple-diagnostic complex (STDC) for obtaining the reliable data on the coolant temperature in the reactors of NPP is described. The STDC in based on the thermal pulse monitoring of a thermocouple in the measuring channel of a reactor. Measurement method and STDC composition are substantiated. It is shown that introduction of the developed STDC ensures realization of precise and reliable temperature monitoring in the reactors of all types [ru

  6. Reliability Evaluation of Bridges Based on Nonprobabilistic Response Surface Limit Method

    Directory of Open Access Journals (Sweden)

    Xuyong Chen

    2017-01-01

    Full Text Available Due to many uncertainties in nonprobabilistic reliability assessment of bridges, the limit state function is generally unknown. The traditional nonprobabilistic response surface method is a lengthy and oscillating iteration process and leads to difficultly solving the nonprobabilistic reliability index. This article proposes a nonprobabilistic response surface limit method based on the interval model. The intention of this method is to solve the upper and lower limits of the nonprobabilistic reliability index and to narrow the range of the nonprobabilistic reliability index. If the range of the reliability index reduces to an acceptable accuracy, the solution will be considered convergent, and the nonprobabilistic reliability index will be obtained. The case study indicates that using the proposed method can avoid oscillating iteration process, make iteration process stable and convergent, reduce iteration steps significantly, and improve computational efficiency and precision significantly compared with the traditional nonprobabilistic response surface method. Finally, the nonprobabilistic reliability evaluation process of bridge will be built through evaluating the reliability of one PC continuous rigid frame bridge with three spans using the proposed method, which appears to be more simple and reliable when lack of samples and parameters in the bridge nonprobabilistic reliability evaluation is present.

  7. An Efficient Method of Vibration Diagnostics For Rotating Machinery Using a Decision Tree

    Directory of Open Access Journals (Sweden)

    Bo Suk Yang

    2000-01-01

    Full Text Available This paper describes an efficient method to automatize vibration diagnosis for rotating machinery using a decision tree, which is applicable to vibration diagnosis expert system. Decision tree is a widely known formalism for expressing classification knowledge and has been used successfully in many diverse areas such as character recognition, medical diagnosis, and expert systems, etc. In order to build a decision tree for vibration diagnosis, we have to define classes and attributes. A set of cases based on past experiences is also needed. This training set is inducted using a result-cause matrix newly developed in the present work instead of using a conventionally implemented cause-result matrix. This method was applied to diagnostics for various cases taken from published work. It is found that the present method predicts causes of the abnormal vibration for test cases with high reliability.

  8. Exploration of analysis methods for diagnostic imaging tests: problems with ROC AUC and confidence scores in CT colonography.

    Science.gov (United States)

    Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G

    2014-01-01

    Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.

  9. Non-invasive diagnostic methods in dentistry

    Science.gov (United States)

    Todea, Carmen

    2016-03-01

    The paper, will present the most important non-invasive methods for diagnostic, in different fields of dentistry. Moreover, the laser-based methods will be emphasis. In orthodontics, 3D laser scanners are increasingly being used to establish database for normative population and cross-sectional growth changes but also to asses clinical outcomes in orthognatic surgical and non-surgical treatments. In prevention the main methods for diagnostic of demineralization and caries detection in early stages are represented by laser fluorescence - Quantitative Light Florescence (QLF); DiagnoDent-system-655nm; FOTI-Fiberoptic transillumination; DIFOTI-Digital Imaging Fiberoptic transillumination; and Optical Coherence Tomography (OCT). In odontology, Laser Doppler Flowmetry (LDF) is a noninvasive real time method used for determining the tooth vitality by monitoring the pulp microcirculation in traumatized teeth, fractured teeth, and teeth undergoing different conservative treatments. In periodontology, recently study shows the ability of LDF to evaluate the health of gingival tissue in periodontal tissue diseases but also after different periodontal treatments.

  10. Diagnostic reliability of 3.0-T MRI for detecting osseous abnormalities of the temporomandibular joint.

    Science.gov (United States)

    Sawada, Kunihiko; Amemiya, Toshihiko; Hirai, Shigenori; Hayashi, Yusuke; Suzuki, Toshihiro; Honda, Masahiko; Sisounthone, Johnny; Matsumoto, Kunihito; Honda, Kazuya

    2018-01-01

    We compared the diagnostic reliability of 3.0-T magnetic resonance imaging (MRI) for detection of osseous abnormalities of the temporomandibular joint (TMJ) with that of the gold standard, cone-beam computed tomography (CBCT). Fifty-six TMJs were imaged with CBCT and MRI, and images of condyles and fossae were independently assessed for the presence of osseous abnormalities. The accuracy, sensitivity, and specificity of 3.0-T MRI were 0.88, 1.0, and 0.73, respectively, in condyle evaluation and 0.91, 0.75, and 0.95 in fossa evaluation. The McNemar test showed no significant difference (P > 0.05) between MRI and CBCT in the evaluation of osseous abnormalities in condyles and fossae. The present results indicate that 3.0-T MRI is equal to CBCT in the diagnostic evaluation of osseous abnormalities of the mandibular condyle.

  11. Prioritic directions of inculcation of diagnostic equipment at NPP

    International Nuclear Information System (INIS)

    Morozov, V.I.

    2000-01-01

    The diagnostic provision creates the conditions for increasing the safety and reliability of the NPP functioning, technical service and maintenance by the actual state. With an account of the large number of the NPP equipment elements, limitedness of financial resources, different technical-economical effect from diagnostics determination of the priority directions for introduction of technical diagnostic means into the operational practice is one of the main factors. The method for determining the above-mentioned priorities is proposed. The main aspects of the method and mathematical models, based on the logical-probabilistic modeling, are presented. The essence of the method consists in ranging the technical-economical effect from introduction of various factors of the diagnostic equipment [ru

  12. Human Reliability Analysis for Design: Using Reliability Methods for Human Factors Issues

    Energy Technology Data Exchange (ETDEWEB)

    Ronald Laurids Boring

    2010-11-01

    This paper reviews the application of human reliability analysis methods to human factors design issues. An application framework is sketched in which aspects of modeling typically found in human reliability analysis are used in a complementary fashion to the existing human factors phases of design and testing. The paper provides best achievable practices for design, testing, and modeling. Such best achievable practices may be used to evaluate and human system interface in the context of design safety certifications.

  13. Human Reliability Analysis for Design: Using Reliability Methods for Human Factors Issues

    International Nuclear Information System (INIS)

    Boring, Ronald Laurids

    2010-01-01

    This paper reviews the application of human reliability analysis methods to human factors design issues. An application framework is sketched in which aspects of modeling typically found in human reliability analysis are used in a complementary fashion to the existing human factors phases of design and testing. The paper provides best achievable practices for design, testing, and modeling. Such best achievable practices may be used to evaluate and human system interface in the context of design safety certifications.

  14. Review of methods for the integration of reliability and design engineering

    International Nuclear Information System (INIS)

    Reilly, J.T.

    1978-03-01

    A review of methods for the integration of reliability and design engineering was carried out to establish a reliability program philosophy, an initial set of methods, and procedures to be used by both the designer and reliability analyst. The report outlines a set of procedures which implements a philosophy that requires increased involvement by the designer in reliability analysis. Discussions of each method reviewed include examples of its application

  15. Punction methods of diagnostics and treatment of thyroid diseases

    Directory of Open Access Journals (Sweden)

    A.S. Tolstokorov

    2010-06-01

    Full Text Available The object of this research is to study the punction methods role under diagnostics and treatment of different thyroid diseases. The authors of this article present treatment methods of 121 patients with different thyroid diseases. The received results allow to draw a conclusion, that punction methods of diagnostics and treatment of thyroid disease can be used as independent methods of treatment and in a complex with other medication remedies

  16. Veterinary Molecular Diagnostics

    NARCIS (Netherlands)

    Roest, H.I.J.; Engelsma, M.Y.; Weesendorp, E.; Bossers, A.; Elbers, A.R.W.

    2017-01-01

    In veterinary molecular diagnostics, samples originating from animals are tested. Developments in the farm animals sector and in our societal attitude towards pet animals have resulted in an increased demand for fast and reliable diagnostic techniques. Molecular diagnostics perfectly matches this

  17. A Fault Diagnostic Method for Position Sensor of Switched Reluctance Wind Generator

    DEFF Research Database (Denmark)

    Wang, Chao; Liu, Xiao; Liu, Hui

    2016-01-01

    Fast and accurate fault diagnosis of the position sensor is of great significance to ensure the reliability as well as sensor fault tolerant operation of the Switched Reluctance Wind Generator (SRWG). This paper presents a fault diagnostic scheme for a SRWG based on the residual between the estim...

  18. Reliability of Estimation Pile Load Capacity Methods

    Directory of Open Access Journals (Sweden)

    Yudhi Lastiasih

    2014-04-01

    Full Text Available None of numerous previous methods for predicting pile capacity is known how accurate any of them are when compared with the actual ultimate capacity of piles tested to failure. The author’s of the present paper have conducted such an analysis, based on 130 data sets of field loading tests. Out of these 130 data sets, only 44 could be analysed, of which 15 were conducted until the piles actually reached failure. The pile prediction methods used were: Brinch Hansen’s method (1963, Chin’s method (1970, Decourt’s Extrapolation Method (1999, Mazurkiewicz’s method (1972, Van der Veen’s method (1953, and the Quadratic Hyperbolic Method proposed by Lastiasih et al. (2012. It was obtained that all the above methods were sufficiently reliable when applied to data from pile loading tests that loaded to reach failure. However, when applied to data from pile loading tests that loaded without reaching failure, the methods that yielded lower values for correction factor N are more recommended. Finally, the empirical method of Reese and O’Neill (1988 was found to be reliable enough to be used to estimate the Qult of a pile foundation based on soil data only.

  19. A SOFTWARE RELIABILITY ESTIMATION METHOD TO NUCLEAR SAFETY SOFTWARE

    Directory of Open Access Journals (Sweden)

    GEE-YONG PARK

    2014-02-01

    Full Text Available A method for estimating software reliability for nuclear safety software is proposed in this paper. This method is based on the software reliability growth model (SRGM, where the behavior of software failure is assumed to follow a non-homogeneous Poisson process. Two types of modeling schemes based on a particular underlying method are proposed in order to more precisely estimate and predict the number of software defects based on very rare software failure data. The Bayesian statistical inference is employed to estimate the model parameters by incorporating software test cases as a covariate into the model. It was identified that these models are capable of reasonably estimating the remaining number of software defects which directly affects the reactor trip functions. The software reliability might be estimated from these modeling equations, and one approach of obtaining software reliability value is proposed in this paper.

  20. THE CURRENT METHODS FOR MOLECULAR DIAGNOSTICS OF FISH DISEASES (REVIEW

    Directory of Open Access Journals (Sweden)

    O. Zaloilo

    2016-06-01

    Full Text Available Purpose. The methods of molecular diagnostic (MMD gradually become widespread in modern fish farming. MMD contain a wide variety of specific approaches, each of which has distinct limits of their possible applications and is characterized by individual peculiarities in practical performance. In addition to high sensitivity and the possibility of rapid diagnostics, the main advantage of molecular methods is to determine the uncultivated infectious agents. DNA amplification allows identifying pathogenic microorganisms at very small quantities even in the minimum sample volume. Molecular methods of diagnostic enable the determination of infection in latent or acute phases. These methods allow showing the differences between pathogens with similar antigenic structures. The current literature data on this subject usually show a methodology in the narrow context of the tasks or practical results obtained through such approaches. Thus, a synthesis of existing information on the mechanisms of action and the limits of the typical problems of basic methods of molecular diagnostics are an urgent task of fish breeding. In particular, the following description will more effectively choose one or several approaches to identify pathogens in fish. Findings. This paper reviews the basic molecular methods that are used in the world's aquaculture for diagnosis of various diseases in commercial fish species. Originality. This work is a generalization of data on the principles and mechanisms for the implementation of diagnostics based on modern molecular techniques. For each of the mentioned approaches, the most promising areas of application were shown. The information is provided in the form of a comparative analysis of each methodology, indicating positive and negative practical aspects. Practical value. The current review of modern methods of molecular diagnostic in aquaculture is focused on practical application. Generalizing and analytical information can be

  1. Convergence diagnostics for Eigenvalue problems with linear regression model

    International Nuclear Information System (INIS)

    Shi, Bo; Petrovic, Bojan

    2011-01-01

    Although the Monte Carlo method has been extensively used for criticality/Eigenvalue problems, a reliable, robust, and efficient convergence diagnostics method is still desired. Most methods are based on integral parameters (multiplication factor, entropy) and either condense the local distribution information into a single value (e.g., entropy) or even disregard it. We propose to employ the detailed cycle-by-cycle local flux evolution obtained by using mesh tally mechanism to assess the source and flux convergence. By applying a linear regression model to each individual mesh in a mesh tally for convergence diagnostics, a global convergence criterion can be obtained. We exemplify this method on two problems and obtain promising diagnostics results. (author)

  2. Application of noise analysis methods in nuclear reactor diagnostics

    International Nuclear Information System (INIS)

    Dach, K.

    1985-01-01

    By statistical evaluation of the fluctuation component of signals from selected detectors, noise diagnostics detects conditions of equipment which might later result in failure. The objective of early diagnostics is to detect the failed integrity of primary circuit components, failed detectors or anomalies of the thermohydraulic process. The commonest method of experimental data analysis is spectral analysis in the frequency range 0 to 50 Hz. Recently, expert diagnostic systems have been built based on artificial intelligence systems. Czechoslovakia participates in the experimental research of noise diagnostics in the context of the development of diagnostic assemblies for WWER-440 reactors. (M.D.)

  3. Advances in methods and applications of reliability and safety analysis

    International Nuclear Information System (INIS)

    Fieandt, J.; Hossi, H.; Laakso, K.; Lyytikaeinen, A.; Niemelae, I.; Pulkkinen, U.; Pulli, T.

    1986-01-01

    The know-how of the reliability and safety design and analysis techniques of Vtt has been established over several years in analyzing the reliability in the Finnish nuclear power plants Loviisa and Olkiluoto. This experience has been later on applied and developed to be used in the process industry, conventional power industry, automation and electronics. VTT develops and transfers methods and tools for reliability and safety analysis to the private and public sectors. The technology transfer takes place in joint development projects with potential users. Several computer-aided methods, such as RELVEC for reliability modelling and analysis, have been developed. The tool developed are today used by major Finnish companies in the fields of automation, nuclear power, shipbuilding and electronics. Development of computer-aided and other methods needed in analysis of operating experience, reliability or safety is further going on in a number of research and development projects

  4. Reliability-based design optimization via high order response surface method

    International Nuclear Information System (INIS)

    Li, Hong Shuang

    2013-01-01

    To reduce the computational effort of reliability-based design optimization (RBDO), the response surface method (RSM) has been widely used to evaluate reliability constraints. We propose an efficient methodology for solving RBDO problems based on an improved high order response surface method (HORSM) that takes advantage of an efficient sampling method, Hermite polynomials and uncertainty contribution concept to construct a high order response surface function with cross terms for reliability analysis. The sampling method generates supporting points from Gauss-Hermite quadrature points, which can be used to approximate response surface function without cross terms, to identify the highest order of each random variable and to determine the significant variables connected with point estimate method. The cross terms between two significant random variables are added to the response surface function to improve the approximation accuracy. Integrating the nested strategy, the improved HORSM is explored in solving RBDO problems. Additionally, a sampling based reliability sensitivity analysis method is employed to reduce the computational effort further when design variables are distributional parameters of input random variables. The proposed methodology is applied on two test problems to validate its accuracy and efficiency. The proposed methodology is more efficient than first order reliability method based RBDO and Monte Carlo simulation based RBDO, and enables the use of RBDO as a practical design tool.

  5. Reliability methods in nuclear power plant ageing management

    International Nuclear Information System (INIS)

    Simola, K.

    1999-01-01

    The aim of nuclear power plant ageing management is to maintain an adequate safety level throughout the lifetime of the plant. In ageing studies, the reliability of components, systems and structures is evaluated taking into account the possible time-dependent degradation. The phases of ageing analyses are generally the identification of critical components, identification and evaluation of ageing effects, and development of mitigation methods. This thesis focuses on the use of reliability methods and analyses of plant- specific operating experience in nuclear power plant ageing studies. The presented applications and method development have been related to nuclear power plants, but many of the approaches can also be applied outside the nuclear industry. The thesis consists of a summary and seven publications. The summary provides an overview of ageing management and discusses the role of reliability methods in ageing analyses. In the publications, practical applications and method development are described in more detail. The application areas at component and system level are motor-operated valves and protection automation systems, for which experience-based ageing analyses have been demonstrated. Furthermore, Bayesian ageing models for repairable components have been developed, and the management of ageing by improving maintenance practices is discussed. Recommendations for improvement of plant information management in order to facilitate ageing analyses are also given. The evaluation and mitigation of ageing effects on structural components is addressed by promoting the use of probabilistic modelling of crack growth, and developing models for evaluation of the reliability of inspection results. (orig.)

  6. Reliability methods in nuclear power plant ageing management

    Energy Technology Data Exchange (ETDEWEB)

    Simola, K. [VTT Automation, Espoo (Finland). Industrial Automation

    1999-07-01

    The aim of nuclear power plant ageing management is to maintain an adequate safety level throughout the lifetime of the plant. In ageing studies, the reliability of components, systems and structures is evaluated taking into account the possible time-dependent degradation. The phases of ageing analyses are generally the identification of critical components, identification and evaluation of ageing effects, and development of mitigation methods. This thesis focuses on the use of reliability methods and analyses of plant- specific operating experience in nuclear power plant ageing studies. The presented applications and method development have been related to nuclear power plants, but many of the approaches can also be applied outside the nuclear industry. The thesis consists of a summary and seven publications. The summary provides an overview of ageing management and discusses the role of reliability methods in ageing analyses. In the publications, practical applications and method development are described in more detail. The application areas at component and system level are motor-operated valves and protection automation systems, for which experience-based ageing analyses have been demonstrated. Furthermore, Bayesian ageing models for repairable components have been developed, and the management of ageing by improving maintenance practices is discussed. Recommendations for improvement of plant information management in order to facilitate ageing analyses are also given. The evaluation and mitigation of ageing effects on structural components is addressed by promoting the use of probabilistic modelling of crack growth, and developing models for evaluation of the reliability of inspection results. (orig.)

  7. Contributions of cytology examination and methods in lung cancer diagnostic

    International Nuclear Information System (INIS)

    Jerse, M.; Tercelj, M.

    2006-01-01

    Background. Lung cancer (LC) is still the leading cause of cancer death according to published data worldwide and confirmed also by the data obtained from the central Cancer Registry of Slovenia. Early detection of LC has an important impact on the long-term survival rate of the patients. In spite of a great advance in imaging technology for a better visualization and early detection of the neoplasms and a variety of screening tests, only cytopathology examination finally define the neoplastic lesion. Methods. To evaluate the contribution of cytology examination in the diagnosis of LC we studied the cytology diagnoses, comparing them with histology reports in patients, who underwent the diagnostic procedure under suspicion of the LC during last 2 years. Results. Of a total 772 patients, in 241 patients cancer was microscopically confirmed. The most frequent diagnoses were adenocarcinoma (36.9%), squamous cell carcinoma (26.6%), and small cell carcinoma (SCLC) (12.9%). There were 22% of neoplasms classified as non-small cell carcinomas (NSCLC). From the clinician point of view considering the therapy it is very important to distinguish NSCLC from SCLC. And in our study the cytology-histology correlation between these two major types of carcinoma was almost 100%. Based only on cytology, 68 (28.2%) patients received microscopic diagnosis of malignoma, and the specimens for this group of patients were obtained mostly from transbronchial or transthoracic fine needle aspiration biopsies. Conclusions. Cytology is of great diagnostic value, a reliable and relatively non-invasive method for patients. Cytology specimens should be taken in cases where it is not possible to obtain samples for histology. (author)

  8. Lithium Battery Transient Response as a Diagnostic Tool

    Science.gov (United States)

    Denisov, E.; Nigmatullin, R.; Evdokimov, Y.; Timergalina, G.

    2018-05-01

    Lithium batteries are currently used as the main energy storage for electronic devices. Progress in the field of portable electronic devices is significantly determined by the improvement of their weight/dimensional characteristics and specific capacity. In addition to the high reliability required of lithium batteries, in some critical applications proper diagnostics are required. Corresponding techniques allow prediction and prevention of operation interruption and avoidance of expensive battery replacement, and also provide additional benefits. Many effective diagnostic methods have been suggested; however, most of them require expensive experimental equipment, as well as interruption or strong perturbation of the operating mode. In the framework of this investigation, a simple diagnostic method based on analysis of transient processes is proposed. The transient response is considered as a reaction to an applied load variation that typically corresponds to normal operating conditions for most real applications. The transient response contains the same information as the impedance characteristic for the system operating in linear mode. Taking into account the large number of publications describing the impedance response associated with diagnostic methods, it can be assumed that the transient response contains a sufficient amount of information for creation of effective diagnostic systems. The proposed experimental installation is based on a controlled load, providing current variation, measuring equipment, and data processing electronics. It is proposed to use the second exponent parameters U 2 and β to estimate the state of charge for secondary lithium batteries. The proposed method improves the accuracy and reliability of a set of quantitative parameters associated with electrochemical energy sources.

  9. Structural hybrid reliability index and its convergent solving method based on random–fuzzy–interval reliability model

    Directory of Open Access Journals (Sweden)

    Hai An

    2016-08-01

    Full Text Available Aiming to resolve the problems of a variety of uncertainty variables that coexist in the engineering structure reliability analysis, a new hybrid reliability index to evaluate structural hybrid reliability, based on the random–fuzzy–interval model, is proposed in this article. The convergent solving method is also presented. First, the truncated probability reliability model, the fuzzy random reliability model, and the non-probabilistic interval reliability model are introduced. Then, the new hybrid reliability index definition is presented based on the random–fuzzy–interval model. Furthermore, the calculation flowchart of the hybrid reliability index is presented and it is solved using the modified limit-step length iterative algorithm, which ensures convergence. And the validity of convergent algorithm for the hybrid reliability model is verified through the calculation examples in literature. In the end, a numerical example is demonstrated to show that the hybrid reliability index is applicable for the wear reliability assessment of mechanisms, where truncated random variables, fuzzy random variables, and interval variables coexist. The demonstration also shows the good convergence of the iterative algorithm proposed in this article.

  10. Comparison of Model Reliabilities from Single-Step and Bivariate Blending Methods

    DEFF Research Database (Denmark)

    Taskinen, Matti; Mäntysaari, Esa; Lidauer, Martin

    2013-01-01

    Model based reliabilities in genetic evaluation are compared between three methods: animal model BLUP, single-step BLUP, and bivariate blending after genomic BLUP. The original bivariate blending is revised in this work to better account animal models. The study data is extracted from...... be calculated. Model reliabilities by the single-step and the bivariate blending methods were higher than by animal model due to genomic information. Compared to the single-step method, the bivariate blending method reliability estimates were, in general, lower. Computationally bivariate blending method was......, on the other hand, lighter than the single-step method....

  11. Cocoa swollen shoot virus in Ghana: A review of diagnostic ...

    African Journals Online (AJOL)

    A quick and more reliable diagnostic method has for a long time been identified as one input that will greatly enhance the control of the cocoa swollen shoot disease in Ghana. Many diagnostic procedures have been developed for detecting the virus that causes the disease; yet, the detection of latent infections is still ...

  12. Statistical models and methods for reliability and survival analysis

    CERN Document Server

    Couallier, Vincent; Huber-Carol, Catherine; Mesbah, Mounir; Huber -Carol, Catherine; Limnios, Nikolaos; Gerville-Reache, Leo

    2013-01-01

    Statistical Models and Methods for Reliability and Survival Analysis brings together contributions by specialists in statistical theory as they discuss their applications providing up-to-date developments in methods used in survival analysis, statistical goodness of fit, stochastic processes for system reliability, amongst others. Many of these are related to the work of Professor M. Nikulin in statistics over the past 30 years. The authors gather together various contributions with a broad array of techniques and results, divided into three parts - Statistical Models and Methods, Statistical

  13. Results of a Demonstration Assessment of Passive System Reliability Utilizing the Reliability Method for Passive Systems (RMPS)

    Energy Technology Data Exchange (ETDEWEB)

    Bucknor, Matthew; Grabaskas, David; Brunett, Acacia; Grelle, Austin

    2015-04-26

    Advanced small modular reactor designs include many advantageous design features such as passively driven safety systems that are arguably more reliable and cost effective relative to conventional active systems. Despite their attractiveness, a reliability assessment of passive systems can be difficult using conventional reliability methods due to the nature of passive systems. Simple deviations in boundary conditions can induce functional failures in a passive system, and intermediate or unexpected operating modes can also occur. As part of an ongoing project, Argonne National Laboratory is investigating various methodologies to address passive system reliability. The Reliability Method for Passive Systems (RMPS), a systematic approach for examining reliability, is one technique chosen for this analysis. This methodology is combined with the Risk-Informed Safety Margin Characterization (RISMC) approach to assess the reliability of a passive system and the impact of its associated uncertainties. For this demonstration problem, an integrated plant model of an advanced small modular pool-type sodium fast reactor with a passive reactor cavity cooling system is subjected to a station blackout using RELAP5-3D. This paper discusses important aspects of the reliability assessment, including deployment of the methodology, the uncertainty identification and quantification process, and identification of key risk metrics.

  14. THE HARMONIZATION AND OPTIMIZATION OF DIAGNOSTIC METHODS FOR A BELT CONVEYOR

    Directory of Open Access Journals (Sweden)

    František HELEBRANT

    2012-04-01

    Full Text Available The final aim of the project MPO FR‐T11/537 called “The Complex Diagnostic System for the Belt Transport” is a single part custom manufacturing and sale of complex diagnostic system for belt transportation and related services. The output of the project is a prototype of a diagnostic system on a model belt conveyor with prepared and certified diagnostic services and methods including their measurements and other supportive tools. The article will introduce the present state of the solution for the given grant project, especially in the field of suggested work on the diagnostic and supportive methods and other measurements.

  15. Scoring of the radiological picture of idiopathic interstitial pneumonia: a study to verify the reliability of the method

    International Nuclear Information System (INIS)

    Kocova, Eva; Vanasek, Jiri; Koblizek, Vladimir; Novosad, Jakub; Elias, Pavel; Bartos, Vladimir; Sterclova, Martina

    2015-01-01

    Idiopathic pulmonary fibrosis (IPF) is a clinical form of usual interstitial pneumonia (UIP). Computed chest tomography (CT) has a fundamental role in the multidisciplinary diagnostics. However, it has not been verified if and how a subjective opinion of a radiologists or pneumologists can influence the assessment and overall diagnostic summary. To verify the reliability of the scoring system. Assessment of conformity of the radiological score of high-resolution CT (HRCT) of lungs in patients with IPF was performed by a group of radiologists and pneumologists. Personal data were blinded and the assessment was performed independently using the Dutka/Vasakova scoring system (modification of the Gay system). The final score of the single assessors was then evaluated by means of the paired Spearman’s correlation and analysis of the principal components. Two principal components explaining cumulatively a 62% or 73% variability of the assessment of the single assessors were extracted during the analysis. The groups did not differ both in terms of specialty and experience with the assessment of the HRCT findings. According to our study, scoring of a radiological image using the Dutka/Vasakova system is a reliable method in the hands of experienced radiologists. Significant differences occur during the assessment performed by pneumologists especially during the evaluation of the alveolar changes

  16. A study on the value of computer-assisted assessment for SPECT/CT-scans in sentinel lymph node diagnostics of penile cancer as well as clinical reliability and morbidity of this procedure.

    Science.gov (United States)

    Lützen, Ulf; Naumann, Carsten Maik; Marx, Marlies; Zhao, Yi; Jüptner, Michael; Baumann, René; Papp, László; Zsótér, Norbert; Aksenov, Alexey; Jünemann, Klaus-Peter; Zuhayra, Maaz

    2016-09-07

    Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial

  17. Assessment of modern methods of human factor reliability analysis in PSA studies

    International Nuclear Information System (INIS)

    Holy, J.

    2001-12-01

    The report is structured as follows: Classical terms and objects (Probabilistic safety assessment as a framework for human reliability assessment; Human failure within the PSA model; Basic types of operator failure modelled in a PSA study and analyzed by HRA methods; Qualitative analysis of human reliability; Quantitative analysis of human reliability used; Process of analysis of nuclear reactor operator reliability in a PSA study); New terms and objects (Analysis of dependences; Errors of omission; Errors of commission; Error forcing context); and Overview and brief assessment of human reliability analysis (Basic characteristics of the methods; Assets and drawbacks of the use of each of HRA method; History and prospects of the use of the methods). (P.A.)

  18. Method for assessing reliability of a network considering probabilistic safety assessment

    International Nuclear Information System (INIS)

    Cepin, M.

    2005-01-01

    A method for assessment of reliability of the network is developed, which uses the features of the fault tree analysis. The method is developed in a way that the increase of the network under consideration does not require significant increase of the model. The method is applied to small examples of network consisting of a small number of nodes and a small number of their connections. The results give the network reliability. They identify equipment, which is to be carefully maintained in order that the network reliability is not reduced, and equipment, which is a candidate for redundancy, as this would improve network reliability significantly. (author)

  19. A new approach for interexaminer reliability data analysis on dental caries calibration

    Directory of Open Access Journals (Sweden)

    Andréa Videira Assaf

    2007-12-01

    Full Text Available Objectives: a to evaluate the interexaminer reliability in caries detection considering different diagnostic thresholds and b to indicate, by using Kappa statistics, the best way of measuring interexaminer agreement during the calibration process in dental caries surveys. Methods: Eleven dentists participated in the initial training, which was divided into theoretical discussions and practical activities, and calibration exercises, performed at baseline, 3 and 6 months after the initial training. For the examinations of 6-7-year-old schoolchildren, the World Health Organization (WHO recommendations were followed and different diagnostic thresholds were used: WHO (decayed/missing/filled teeth - DMFT index and WHO + IL (initial lesion diagnostic thresholds. The interexaminer reliability was calculated by Kappa statistics, according to WHO and WHO+IL thresholds considering: a the entire dentition; b upper/lower jaws; c sextants; d each tooth individually. Results: Interexaminer reliability was high for both diagnostic thresholds; nevertheless, it decreased in all calibration sections when considering teeth individually. Conclusion: The interexaminer reliability was possible during the period of 6 months, under both caries diagnosis thresholds. However, great disagreement was observed for posterior teeth, especially using the WHO+IL criteria. Analysis considering dental elements individually was the best way of detecting interexaminer disagreement during the calibration sections.

  20. Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.

    Science.gov (United States)

    Alagrund, Katariina; Orpana, Arto K

    2014-01-01

    The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.

  1. Validity and reliability of the Thai version of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU

    Directory of Open Access Journals (Sweden)

    Pipanmekaporn T

    2014-05-01

    Full Text Available Tanyong Pipanmekaporn,1 Nahathai Wongpakaran,2 Sirirat Mueankwan,3 Piyawat Dendumrongkul,2 Kaweesak Chittawatanarat,3 Nantiya Khongpheng,3 Nongnut Duangsoy31Department of Anesthesiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand; 2Department of Psychiatry, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand; 3Division of Surgical Critical Care and Trauma, Department of Surgery, Chiang Mai University Hospital, Chiang Mai, ThailandPurpose: The purpose of this study was to determine the validity and reliability of the Thai version of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU, when compared to the diagnoses made by delirium experts.Patients and methods: This was a cross-sectional study conducted in both surgical intensive care and subintensive care units in Thailand between February–June 2011. Seventy patients aged 60 years or older who had been admitted to the units were enrolled into the study within the first 48 hours of admission. Each patient was randomly assessed as to whether they had delirium by a nurse using the Thai version of the CAM-ICU algorithm (Thai CAM-ICU or by a delirium expert using the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision.Results: The prevalence of delirium was found to be 18.6% (n=13 by the delirium experts. The sensitivity of the Thai CAM-ICU’s algorithms was found to be 92.3% (95% confidence interval [CI] =64.0%-99.8%, while the specificity was 94.7% (95% CI =85.4%-98.9%. The instrument displayed good interrater reliability (Cohen’s κ=0.81; 95% CI =0.64-0.99. The time taken to complete the Thai CAM-ICU was 1 minute (interquatile range, 1-2 minutes.Conclusion: The Thai CAM-ICU demonstrated good validity, reliability, and ease of use when diagnosing delirium in a surgical intensive care unit setting. The use of this diagnostic tool should be encouraged for daily, routine use, so as to promote the early detection

  2. Assessment of the reliability of ultrasonic inspection methods

    International Nuclear Information System (INIS)

    Haines, N.F.; Langston, D.B.; Green, A.J.; Wilson, R.

    1982-01-01

    The reliability of NDT techniques has remained an open question for many years. A reliable technique may be defined as one that, when rigorously applied by a number of inspection teams, consistently finds then correctly sizes all defects of concern. In this paper we report an assessment of the reliability of defect detection by manual ultrasonic methods applied to the inspection of thick section pressure vessel weldments. Initially we consider the available data relating to the inherent physical capabilities of ultrasonic techniques to detect cracks in weldment and then, independently, we assess the likely variability in team to team performance when several teams are asked to follow the same specified test procedure. The two aspects of 'capability' and 'variability' are brought together to provide quantitative estimates of the overall reliability of ultrasonic inspection of thick section pressure vessel weldments based on currently existing data. The final section of the paper considers current research programmes on reliability and presents a view on how these will help to further improve NDT reliability. (author)

  3. RELIABILITY ASSESSMENT OF ENTROPY METHOD FOR SYSTEM CONSISTED OF IDENTICAL EXPONENTIAL UNITS

    Institute of Scientific and Technical Information of China (English)

    Sun Youchao; Shi Jun

    2004-01-01

    The reliability assessment of unit-system near two levels is the most important content in the reliability multi-level synthesis of complex systems. Introducing the information theory into system reliability assessment, using the addible characteristic of information quantity and the principle of equivalence of information quantity, an entropy method of data information conversion is presented for the system consisted of identical exponential units. The basic conversion formulae of entropy method of unit test data are derived based on the principle of information quantity equivalence. The general models of entropy method synthesis assessment for system reliability approximate lower limits are established according to the fundamental principle of the unit reliability assessment. The applications of the entropy method are discussed by way of practical examples. Compared with the traditional methods, the entropy method is found to be valid and practicable and the assessment results are very satisfactory.

  4. Sequential optimization and reliability assessment method for metal forming processes

    International Nuclear Information System (INIS)

    Sahai, Atul; Schramm, Uwe; Buranathiti, Thaweepat; Chen Wei; Cao Jian; Xia, Cedric Z.

    2004-01-01

    Uncertainty is inevitable in any design process. The uncertainty could be due to the variations in geometry of the part, material properties or due to the lack of knowledge about the phenomena being modeled itself. Deterministic design optimization does not take uncertainty into account and worst case scenario assumptions lead to vastly over conservative design. Probabilistic design, such as reliability-based design and robust design, offers tools for making robust and reliable decisions under the presence of uncertainty in the design process. Probabilistic design optimization often involves double-loop procedure for optimization and iterative probabilistic assessment. This results in high computational demand. The high computational demand can be reduced by replacing computationally intensive simulation models with less costly surrogate models and by employing Sequential Optimization and reliability assessment (SORA) method. The SORA method uses a single-loop strategy with a series of cycles of deterministic optimization and reliability assessment. The deterministic optimization and reliability assessment is decoupled in each cycle. This leads to quick improvement of design from one cycle to other and increase in computational efficiency. This paper demonstrates the effectiveness of Sequential Optimization and Reliability Assessment (SORA) method when applied to designing a sheet metal flanging process. Surrogate models are used as less costly approximations to the computationally expensive Finite Element simulations

  5. Safety motion increase of trains by improvement diagnostics process devices of railway automation

    Directory of Open Access Journals (Sweden)

    B.M.Bondarenko

    2012-12-01

    Full Text Available The complex use of methods of nondestructive check for the automated diagnostics electromagnetic relays of railway automation the first class reliability is offered. The methods determination of their mechanical parameters are resulted, that allows to exclude a human factor from the control, promote reliability of devices railway automation and safety motion of railway transport.

  6. Reliability Estimation of the Pultrusion Process Using the First-Order Reliability Method (FORM)

    DEFF Research Database (Denmark)

    Baran, Ismet; Tutum, Cem Celal; Hattel, Jesper Henri

    2013-01-01

    In the present study the reliability estimation of the pultrusion process of a flat plate is analyzed by using the first order reliability method (FORM). The implementation of the numerical process model is validated by comparing the deterministic temperature and cure degree profiles...... with corresponding analyses in the literature. The centerline degree of cure at the exit (CDOCE) being less than a critical value and the maximum composite temperature (Tmax) during the process being greater than a critical temperature are selected as the limit state functions (LSFs) for the FORM. The cumulative...

  7. A method to assign failure rates for piping reliability assessments

    International Nuclear Information System (INIS)

    Gamble, R.M.; Tagart, S.W. Jr.

    1991-01-01

    This paper reports on a simplified method that has been developed to assign failure rates that can be used in reliability and risk studies of piping. The method can be applied on a line-by-line basis by identifying line and location specific attributes that can lead to piping unreliability from in-service degradation mechanisms and random events. A survey of service experience for nuclear piping reliability also was performed. The data from this survey provides a basis for identifying in-service failure attributes and assigning failure rates for risk and reliability studies

  8. Reliability analysis of neutron transport simulation using Monte Carlo method

    International Nuclear Information System (INIS)

    Souza, Bismarck A. de; Borges, Jose C.

    1995-01-01

    This work presents a statistical and reliability analysis covering data obtained by computer simulation of neutron transport process, using the Monte Carlo method. A general description of the method and its applications is presented. Several simulations, corresponding to slowing down and shielding problems have been accomplished. The influence of the physical dimensions of the materials and of the sample size on the reliability level of results was investigated. The objective was to optimize the sample size, in order to obtain reliable results, optimizing computation time. (author). 5 refs, 8 figs

  9. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  10. Human reliability analysis methods for probabilistic safety assessment

    International Nuclear Information System (INIS)

    Pyy, P.

    2000-11-01

    Human reliability analysis (HRA) of a probabilistic safety assessment (PSA) includes identifying human actions from safety point of view, modelling the most important of them in PSA models, and assessing their probabilities. As manifested by many incidents and studies, human actions may have both positive and negative effect on safety and economy. Human reliability analysis is one of the areas of probabilistic safety assessment (PSA) that has direct applications outside the nuclear industry. The thesis focuses upon developments in human reliability analysis methods and data. The aim is to support PSA by extending the applicability of HRA. The thesis consists of six publications and a summary. The summary includes general considerations and a discussion about human actions in the nuclear power plant (NPP) environment. A condensed discussion about the results of the attached publications is then given, including new development in methods and data. At the end of the summary part, the contribution of the publications to good practice in HRA is presented. In the publications, studies based on the collection of data on maintenance-related failures, simulator runs and expert judgement are presented in order to extend the human reliability analysis database. Furthermore, methodological frameworks are presented to perform a comprehensive HRA, including shutdown conditions, to study reliability of decision making, and to study the effects of wrong human actions. In the last publication, an interdisciplinary approach to analysing human decision making is presented. The publications also include practical applications of the presented methodological frameworks. (orig.)

  11. A reliability evaluation method for NPP safety DCS application software

    International Nuclear Information System (INIS)

    Li Yunjian; Zhang Lei; Liu Yuan

    2014-01-01

    In the field of nuclear power plant (NPP) digital i and c application, reliability evaluation for safety DCS application software is a key obstacle to be removed. In order to quantitatively evaluate reliability of NPP safety DCS application software, this paper propose a reliability evaluating method based on software development life cycle every stage's v and v defects density characteristics, by which the operating reliability level of the software can be predicted before its delivery, and helps to improve the reliability of NPP safety important software. (authors)

  12. Characteristics and application study of AP1000 NPPs equipment reliability classification method

    International Nuclear Information System (INIS)

    Guan Gao

    2013-01-01

    AP1000 nuclear power plant applies an integrated approach to establish equipment reliability classification, which includes probabilistic risk assessment technique, maintenance rule administrative, power production reliability classification and functional equipment group bounding method, and eventually classify equipment reliability into 4 levels. This classification process and result are very different from classical RCM and streamlined RCM. It studied the characteristic of AP1000 equipment reliability classification approach, considered that equipment reliability classification should effectively support maintenance strategy development and work process control, recommended to use a combined RCM method to establish the future equipment reliability program of AP1000 nuclear power plants. (authors)

  13. Reliability and risk analysis methods research plan

    International Nuclear Information System (INIS)

    1984-10-01

    This document presents a plan for reliability and risk analysis methods research to be performed mainly by the Reactor Risk Branch (RRB), Division of Risk Analysis and Operations (DRAO), Office of Nuclear Regulatory Research. It includes those activities of other DRAO branches which are very closely related to those of the RRB. Related or interfacing programs of other divisions, offices and organizations are merely indicated. The primary use of this document is envisioned as an NRC working document, covering about a 3-year period, to foster better coordination in reliability and risk analysis methods development between the offices of Nuclear Regulatory Research and Nuclear Reactor Regulation. It will also serve as an information source for contractors and others to more clearly understand the objectives, needs, programmatic activities and interfaces together with the overall logical structure of the program

  14. Procedures and methods that increase reliability and reproducibility of the transplanted kidney perfusion index

    International Nuclear Information System (INIS)

    Smokvina, A.

    1994-01-01

    At different times following surgery and during various complications, 119 studies were performed on 57 patients. In many patients studies were repeated several times. Twenty-three studies were performed in as many patients, in whom a normal function of the transplanted kidney was established by other diagnostic methods and retrospective analysis. Comparison was made of the perfusion index results obtained by the Hilson et al. method from 1978 and the ones obtained by my own modified method, which for calculating the index also takes into account: the time difference in appearance of the initial portions of the artery and kidney curves; the positioning of the region of interest over the distal part of the aorta; the bolus injection into the arteriovenous shunt of the forearm with high specific activity of small volumes of Tc-99m labelled agents; a fast 0.5 seconds study of data collection; and a standard for normalization of numerical data. The reliability of one or the other method tested by simulated time shift of the peak of arterial curves shows that the deviation percentage from the main index value in the unmodified method is 2-5 times greater than in the modified method. The normal value of the perfusion index applying the modified method is 91-171. (author)

  15. An assessment of diagnostic efficiency by Taguchi/DEA methods.

    Science.gov (United States)

    Taner, Mehmet Tolga; Sezen, Bulent

    2009-01-01

    The aim of this paper is to propose a new, objective and consistent method for the calculation of the diagnostic efficiency in medical applications. In this study, a hybrid method of Taguchi and DEA is proposed. This method reflects the diversity of inputs and outputs by incorporating the stepwise application of sensitivity, specificity, leveling threshold, and efficiency score. A hypothetical case study is given which involves eight readers of X-ray films in clinical radiology. The selected pairs of sensitivity and specificity yielded two efficient readers. After super efficiency analysis, Reader 6 is found to be the most efficient reader. The paper presents a new, objective and consistent method for the calculation of the diagnostic efficiency in medical applications.

  16. Leak detection by vibrational diagnostic methods

    International Nuclear Information System (INIS)

    Siklossy, P.

    1983-01-01

    The possibilities and methods of leak detection due to mechanical failures in nuclear power plants are reviewed on the basis of the literature. Great importance is attributed to vibrational diagnostic methods for their adventageous characteristics which enable them to become final leak detecting methods. The problems of noise analysis, e.g. leak detection by impact sound measurements, probe characteristics, gain problems, probe selection, off-line analysis and correlation functions, types of leak noises etc. are summarized. Leak detection based on noise analysis can be installed additionally to power plants. Its maintenance and testing is simple. On the other hand, it requires special training and measuring methods. (Sz.J.)

  17. METHODS OF DIAGNOSTIC EFFECTIVENESS ORGANIZATIONAL CHANGES IN CARGO MOTOR TRANSPORTATION ORGANIZATIONS

    Directory of Open Access Journals (Sweden)

    Denis Sergeevich Antipov

    2017-03-01

    Full Text Available The article propose methods of diagnostic effectiveness organizational changes in cargo motor transportation organizations. The article contain the main results approbation of the developed methods of diagnostic effectiveness organizational changes in cargo motor transportation organizations in 37 cargo motor transportation organizations of Saint-Petersburg and the Leningrad Region. Constructed diagrams of conformity specific weights resulting from organizational changes in cargo motor transportation organizations. Presents diagrams effectiveness organizational changes in cargo motor transportation organizations at every stages of the life cycle. The goal of the present paper is to development methods of diagnostic effectiveness organizational changes in cargo motor transportation organizations.

  18. Reliability research to nuclear power plant operators based on several methods

    International Nuclear Information System (INIS)

    Fang Xiang; Li Fu; Zhao Bingquan

    2009-01-01

    The paper utilizes many kinds of international reliability research methods, and summarizes the review of reliability research of Chinese nuclear power plant operators in past over ten years based on the simulator platform of nuclear power plant. The paper shows the necessity and feasibility of the research to nuclear power plant operators from many angles including human cognition reliability, fuzzy mathematics model and psychological research model, etc. It will be good to the safe operation of nuclear power plant based on many kinds of research methods to the reliability research of nuclear power plant operators. (authors)

  19. Interlaboratory diagnostic accuracy of a Salmonella specific PCR-based method

    DEFF Research Database (Denmark)

    Malorny, B.; Hoorfar, Jeffrey; Hugas, M.

    2003-01-01

    A collaborative study involving four European laboratories was conducted to investigate the diagnostic accuracy of a Salmonella specific PCR-based method, which was evaluated within the European FOOD-PCR project (http://www.pcr.dk). Each laboratory analysed by the PCR a set of independent obtained...... presumably naturally contaminated samples and compared the results with the microbiological culture method. The PCR-based method comprised a preenrichment step in buffered peptone water followed by a thermal cell lysis using a closed tube resin-based method. Artificially contaminated minced beef and whole......-based diagnostic methods and is currently proposed as international standard document....

  20. Evaluation of laboratory diagnostic methods for cryptosporidiosis ...

    African Journals Online (AJOL)

    The conventional method of modified Ziehl-Neelsen (MZN) is very laborious, and stool ... Objective: This research was set to evaluate the diagnostic efficacy of ... 93.1% (MZN to ELISA) with ELISA techniques showing the highest sensitivity at ...

  1. Investigation of MLE in nonparametric estimation methods of reliability function

    International Nuclear Information System (INIS)

    Ahn, Kwang Won; Kim, Yoon Ik; Chung, Chang Hyun; Kim, Kil Yoo

    2001-01-01

    There have been lots of trials to estimate a reliability function. In the ESReDA 20 th seminar, a new method in nonparametric way was proposed. The major point of that paper is how to use censored data efficiently. Generally there are three kinds of approach to estimate a reliability function in nonparametric way, i.e., Reduced Sample Method, Actuarial Method and Product-Limit (PL) Method. The above three methods have some limits. So we suggest an advanced method that reflects censored information more efficiently. In many instances there will be a unique maximum likelihood estimator (MLE) of an unknown parameter, and often it may be obtained by the process of differentiation. It is well known that the three methods generally used to estimate a reliability function in nonparametric way have maximum likelihood estimators that are uniquely exist. So, MLE of the new method is derived in this study. The procedure to calculate a MLE is similar just like that of PL-estimator. The difference of the two is that in the new method, the mass (or weight) of each has an influence of the others but the mass in PL-estimator not

  2. Feasibility and cost efficiency of a diagnostic guideline for chronic polyneuropathy : a prospective implementation study

    NARCIS (Netherlands)

    Vrancken, A.F.J.E.; Kalmijn, S.; Buskens, E.; Franssen, H.; Wokke, J.H.J.; Notermans, N.C.

    2006-01-01

    Background: Extensive investigations are often performed to reveal the cause of chronic polyneuropathy. It is not known whether a restrictive diagnostic guideline improves cost efficiency without loss of diagnostic reliability. Methods: In a prospective multicentre study, a comparison was made

  3. Fast Reliability Assessing Method for Distribution Network with Distributed Renewable Energy Generation

    Science.gov (United States)

    Chen, Fan; Huang, Shaoxiong; Ding, Jinjin; Ding, Jinjin; Gao, Bo; Xie, Yuguang; Wang, Xiaoming

    2018-01-01

    This paper proposes a fast reliability assessing method for distribution grid with distributed renewable energy generation. First, the Weibull distribution and the Beta distribution are used to describe the probability distribution characteristics of wind speed and solar irradiance respectively, and the models of wind farm, solar park and local load are built for reliability assessment. Then based on power system production cost simulation probability discretization and linearization power flow, a optimal power flow objected with minimum cost of conventional power generation is to be resolved. Thus a reliability assessment for distribution grid is implemented fast and accurately. The Loss Of Load Probability (LOLP) and Expected Energy Not Supplied (EENS) are selected as the reliability index, a simulation for IEEE RBTS BUS6 system in MATLAB indicates that the fast reliability assessing method calculates the reliability index much faster with the accuracy ensured when compared with Monte Carlo method.

  4. Modifying nodal pricing method considering market participants optimality and reliability

    Directory of Open Access Journals (Sweden)

    A. R. Soofiabadi

    2015-06-01

    Full Text Available This paper develops a method for nodal pricing and market clearing mechanism considering reliability of the system. The effects of components reliability on electricity price, market participants’ profit and system social welfare is considered. This paper considers reliability both for evaluation of market participant’s optimality as well as for fair pricing and market clearing mechanism. To achieve fair pricing, nodal price has been obtained through a two stage optimization problem and to achieve fair market clearing mechanism, comprehensive criteria has been introduced for optimality evaluation of market participant. Social welfare of the system and system efficiency are increased under proposed modified nodal pricing method.

  5. Analysis of Steel Wire Rope Diagnostic Data Applying Multi-Criteria Methods

    Directory of Open Access Journals (Sweden)

    Audrius Čereška

    2018-02-01

    Full Text Available Steel ropes are complex flexible structures used in many technical applications, such as elevators, cable cars, and funicular cabs. Due to the specific design and critical safety requirements, diagnostics of ropes remains an important issue. Broken wire number in the steel ropes is limited by safety standards when they are used in the human lifting and carrying installations. There are some practical issues on loose wires—firstly, it shows end of lifetime of the entire rope, independently of wear, lubrication or wrong winding on the drums or through pulleys; and, secondly, it can stick in the tight pulley—support gaps and cause deterioration of rope structure up to birdcage formations. Normal rope operation should not generate broken wires, so increasing of their number shows a need for rope installation maintenance. This paper presents a methodology of steel rope diagnostics and the results of analysis using multi-criteria analysis methods. The experimental part of the research was performed using an original test bench to detect broken wires on the rope surface by its vibrations. Diagnostics was performed in the range of frequencies from 60 to 560 Hz with a pitch of 50 Hz. The obtained amplitudes of the broken rope wire vibrations, different from the entire rope surface vibration parameters, was the significant outcome. Later analysis of the obtained experimental results revealed the most significant values of the diagnostic parameters. The evaluation of the power of the diagnostics was implemented by using multi-criteria decision-making (MCDM methods. Various decision-making methods are necessary due to unknown efficiencies with respect to the physical phenomena of the evaluated processes. The significance of the methods was evaluated using objective methods from the structure of the presented data. Some of these methods were proposed by authors of this paper. Implementation of MCDM in diagnostic data analysis and definition of the

  6. Level III Reliability methods feasible for complex structures

    NARCIS (Netherlands)

    Waarts, P.H.; Boer, A. de

    2001-01-01

    The paper describes the comparison between three types of reliability methods: code type level I used by a designer, full level I and a level III method. Two cases that are typical for civil engineering practise, a cable-stayed subjected to traffic load and the installation of a soil retaining sheet

  7. Measuring methods for the TFR plasma diagnostics

    International Nuclear Information System (INIS)

    Etievant, C.

    1975-02-01

    The measuring methods in operation or still under development for the diagnostics of the TFR plasma parameters (ion and electron temperatures, electron density, current density are reviewed, the diagnostics of the electrical behavior of the discharge, the neutral gas densities, the impurities and the parameters of the plasma turbulence being also investigated. Actual works are principally devoted to: improving ion temperature measurements by the possible use of the Doppler effect or infra-red incoherent scattering; improving n(e) and T(e) measurement by Thomson scattering; measuring the poloidal field and current density; measuring impurities by X and UV spectroscopy and measuring instabilities and turbulence [fr

  8. Recent advances in computational structural reliability analysis methods

    Science.gov (United States)

    Thacker, Ben H.; Wu, Y.-T.; Millwater, Harry R.; Torng, Tony Y.; Riha, David S.

    1993-10-01

    The goal of structural reliability analysis is to determine the probability that the structure will adequately perform its intended function when operating under the given environmental conditions. Thus, the notion of reliability admits the possibility of failure. Given the fact that many different modes of failure are usually possible, achievement of this goal is a formidable task, especially for large, complex structural systems. The traditional (deterministic) design methodology attempts to assure reliability by the application of safety factors and conservative assumptions. However, the safety factor approach lacks a quantitative basis in that the level of reliability is never known and usually results in overly conservative designs because of compounding conservatisms. Furthermore, problem parameters that control the reliability are not identified, nor their importance evaluated. A summary of recent advances in computational structural reliability assessment is presented. A significant level of activity in the research and development community was seen recently, much of which was directed towards the prediction of failure probabilities for single mode failures. The focus is to present some early results and demonstrations of advanced reliability methods applied to structural system problems. This includes structures that can fail as a result of multiple component failures (e.g., a redundant truss), or structural components that may fail due to multiple interacting failure modes (e.g., excessive deflection, resonate vibration, or creep rupture). From these results, some observations and recommendations are made with regard to future research needs.

  9. Assessment and Improving Methods of Reliability Indices in Bakhtar Regional Electricity Company

    Directory of Open Access Journals (Sweden)

    Saeed Shahrezaei

    2013-04-01

    Full Text Available Reliability of a system is the ability of a system to do prospected duties in future and the probability of desirable operation for doing predetermined duties. Power system elements failures data are the main data of reliability assessment in the network. Determining antiseptic parameters is the goal of reliability assessment by using system history data. These parameters help to recognize week points of the system. In other words, the goal of reliability assessment is operation improving and decreasing of the failures and power outages. This paper is developed to assess reliability indices of Bakhtar Regional Electricity Company up to 1393 and the improving methods and their effects on the reliability indices in this network. DIgSILENT Power Factory software is employed for simulation. Simulation results show the positive effect of improving methods in reliability indices of Bakhtar Regional Electricity Company.

  10. Review of Quantitative Software Reliability Methods

    Energy Technology Data Exchange (ETDEWEB)

    Chu, T.L.; Yue, M.; Martinez-Guridi, M.; Lehner, J.

    2010-09-17

    The current U.S. Nuclear Regulatory Commission (NRC) licensing process for digital systems rests on deterministic engineering criteria. In its 1995 probabilistic risk assessment (PRA) policy statement, the Commission encouraged the use of PRA technology in all regulatory matters to the extent supported by the state-of-the-art in PRA methods and data. Although many activities have been completed in the area of risk-informed regulation, the risk-informed analysis process for digital systems has not yet been satisfactorily developed. Since digital instrumentation and control (I&C) systems are expected to play an increasingly important role in nuclear power plant (NPP) safety, the NRC established a digital system research plan that defines a coherent set of research programs to support its regulatory needs. One of the research programs included in the NRC's digital system research plan addresses risk assessment methods and data for digital systems. Digital I&C systems have some unique characteristics, such as using software, and may have different failure causes and/or modes than analog I&C systems; hence, their incorporation into NPP PRAs entails special challenges. The objective of the NRC's digital system risk research is to identify and develop methods, analytical tools, and regulatory guidance for (1) including models of digital systems into NPP PRAs, and (2) using information on the risks of digital systems to support the NRC's risk-informed licensing and oversight activities. For several years, Brookhaven National Laboratory (BNL) has worked on NRC projects to investigate methods and tools for the probabilistic modeling of digital systems, as documented mainly in NUREG/CR-6962 and NUREG/CR-6997. However, the scope of this research principally focused on hardware failures, with limited reviews of software failure experience and software reliability methods. NRC also sponsored research at the Ohio State University investigating the modeling of

  11. An Intelligent Method for Structural Reliability Analysis Based on Response Surface

    Institute of Scientific and Technical Information of China (English)

    桂劲松; 刘红; 康海贵

    2004-01-01

    As water depth increases, the structural safety and reliability of a system become more and more important and challenging. Therefore, the structural reliability method must be applied in ocean engineering design such as offshore platform design. If the performance function is known in structural reliability analysis, the first-order second-moment method is often used. If the performance function could not be definitely expressed, the response surface method is always used because it has a very clear train of thought and simple programming. However, the traditional response surface method fits the response surface of quadratic polynomials where the problem of accuracy could not be solved, because the true limit state surface can be fitted well only in the area near the checking point. In this paper, an intelligent computing method based on the whole response surface is proposed, which can be used for the situation where the performance function could not be definitely expressed in structural reliability analysis. In this method, a response surface of the fuzzy neural network for the whole area should be constructed first, and then the structural reliability can be calculated by the genetic algorithm. In the proposed method, all the sample points for the training network come from the whole area, so the true limit state surface in the whole area can be fitted. Through calculational examples and comparative analysis, it can be known that the proposed method is much better than the traditional response surface method of quadratic polynomials, because, the amount of calculation of finite element analysis is largely reduced, the accuracy of calculation is improved,and the true limit state surface can be fitted very well in the whole area. So, the method proposed in this paper is suitable for engineering application.

  12. Reliability Evaluation of Bridges Based on Nonprobabilistic Response Surface Limit Method

    OpenAIRE

    Chen, Xuyong; Chen, Qian; Bian, Xiaoya; Fan, Jianping

    2017-01-01

    Due to many uncertainties in nonprobabilistic reliability assessment of bridges, the limit state function is generally unknown. The traditional nonprobabilistic response surface method is a lengthy and oscillating iteration process and leads to difficultly solving the nonprobabilistic reliability index. This article proposes a nonprobabilistic response surface limit method based on the interval model. The intention of this method is to solve the upper and lower limits of the nonprobabilistic ...

  13. Survey of methods used to asses human reliability in the human factors reliability benchmark exercise

    International Nuclear Information System (INIS)

    Poucet, A.

    1988-01-01

    The Joint Research Centre of the European Commission has organised a Human Factors Reliability Benchmark Exercise (HF-RBE) with the aim to assess the state-of-the-art in human reliability modelling and assessment. Fifteen teams from eleven countries, representing industry, utilities, licensing organisations and research institutes, participate in the HF-RBE, which is organised around two study cases: (1) analysis of routine functional test and maintenance procedures, with the aim to assess the probability of test-induced failures, the probability of failures to remain unrevealed, and the potential to initiate transients because of errors performed in the test; and (2) analysis of human actions during an operational transient, with the aim to assess the probability that the operators will correctly diagnose the malfunctions and take proper corrective action. The paper briefly reports how the HF-RBE was structured and gives an overview of the methods that have been used for predicting human reliability in both study cases. The experience in applying these methods is discussed and the results obtained are compared. (author)

  14. Revolutionary diagnostic method using rotating atomic nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Frese, W.

    1986-01-23

    Nuclear tomography, a newcomer in medical diagnostics, has rapidly gained ground and recently achieved a decisive success: Electronic sectional images of the body which hitherto took measuring times of several minutes now can be obtained within only a few seconds. This jump in time has been earned by experts of the Goettingen Max Planck Institute for biophysical chemistry who puzzled out the significant modification of the method, which offers completely new insight to clinical diagnostics. One advantage is that nuclear magnetic resonance imaging - as the method also is called - allows dynamic processes to be made visible, and not only the movements of anatomic structures such as the heart, but indeed also physiological processes such as renal excretion. The other decisive improvement is that three-dimensional images of tissue and organs can be obtained. And on top of it all, nuclear magnetic resonance imaging does not invade the patient's body with harmful radiation.

  15. Revolutionary diagnostic method using rotating atomic nuclei

    International Nuclear Information System (INIS)

    Frese, W.

    1986-01-01

    Nuclear tomography, a newcomer in medical diagnostics, has rapidly gained ground and recently achieved a decisive success: Electronic sectional images of the body which hitherto took measuring times of several minutes now can be obtained within only a few seconds. This jump in time has been earned by experts of the Goettingen Max Planck Institute for biophysical chemistry who puzzled out the significant modification of the method, which offers completely new insight to clinical diagnostics. One advantage is that nuclear magnetic resonance imaging - as the method also is called - allows dynamic processes to be made visible, and not only the movements of anatomic structures such as the heart, but indeed also physiological processes such as renal excretion. The other decisive improvement is that three-dimensional images of tissue and organs can be obtained. And on top of it all, nuclear magnetic resonance imaging does not invade the patient's body with harmful radiation. (orig./MG) [de

  16. Limitations in simulator time-based human reliability analysis methods

    International Nuclear Information System (INIS)

    Wreathall, J.

    1989-01-01

    Developments in human reliability analysis (HRA) methods have evolved slowly. Current methods are little changed from those of almost a decade ago, particularly in the use of time-reliability relationships. While these methods were suitable as an interim step, the time (and the need) has come to specify the next evolution of HRA methods. As with any performance-oriented data source, power plant simulator data have no direct connection to HRA models. Errors reported in data are normal deficiencies observed in human performance; failures are events modeled in probabilistic risk assessments (PRAs). Not all errors cause failures; not all failures are caused by errors. Second, the times at which actions are taken provide no measure of the likelihood of failures to act correctly within an accident scenario. Inferences can be made about human reliability, but they must be made with great care. Specific limitations are discussed. Simulator performance data are useful in providing qualitative evidence of the variety of error types and their potential influences on operating systems. More work is required to combine recent developments in the psychology of error with the qualitative data collected at stimulators. Until data become openly available, however, such an advance will not be practical

  17. Reliably detectable flaw size for NDE methods that use calibration

    Science.gov (United States)

    Koshti, Ajay M.

    2017-04-01

    Probability of detection (POD) analysis is used in assessing reliably detectable flaw size in nondestructive evaluation (NDE). MIL-HDBK-1823 and associated mh18232 POD software gives most common methods of POD analysis. In this paper, POD analysis is applied to an NDE method, such as eddy current testing, where calibration is used. NDE calibration standards have known size artificial flaws such as electro-discharge machined (EDM) notches and flat bottom hole (FBH) reflectors which are used to set instrument sensitivity for detection of real flaws. Real flaws such as cracks and crack-like flaws are desired to be detected using these NDE methods. A reliably detectable crack size is required for safe life analysis of fracture critical parts. Therefore, it is important to correlate signal responses from real flaws with signal responses form artificial flaws used in calibration process to determine reliably detectable flaw size.

  18. Diagnostic Value of Manual and Computerized Methods of Dental Casts Analysis

    Directory of Open Access Journals (Sweden)

    H. Rahimi

    2009-06-01

    Full Text Available Objective: The aim of this study was to evaluate the validity of computerized and manual methods of dental cast analysis.Materials and Methods: Twenty set-ups of upper and lower casts using artificial teeth corresponding to various malocclusions were created for a diagnostic in vitro study. Values of tooth size were calculated from the isolated artificial teeth out of the set-ups, results were considered as a gold standard for the tooth size. Arch width was calculated from the existing set-ups on the dentins.Impressions were taken of the casts with alginate and duplicated with dental stone. Models were measured with digital caliper manually. Then images were taken from the occlusal views of the casts by a digital camera. Measurements were done on digital images with the AutoCAD software.The results of the computerized and manual methods were compared with the gold standard.Intra class correlation coefficient of reliability was used to measure the accuracy ofthe methods and the Friedman technique used to evaluate the significance of differences.Results: Results indicated that all measurements were highly correlated, e.g. gold standard and manual (0.9613-0.9991, gold standard and computerized (0.7118-0.9883, manual and computerized (0.6734-0.9914. Statistically significant differences were present between these methods (P<0.05, but they proved not to be clinically significant.Conclusion: Manual measurement is still the most accurate method when compared to the computerized measurements and the results of measurement by computer should be interpreted with caution.

  19. Statistical Bayesian method for reliability evaluation based on ADT data

    Science.gov (United States)

    Lu, Dawei; Wang, Lizhi; Sun, Yusheng; Wang, Xiaohong

    2018-05-01

    Accelerated degradation testing (ADT) is frequently conducted in the laboratory to predict the products’ reliability under normal operating conditions. Two kinds of methods, degradation path models and stochastic process models, are utilized to analyze degradation data and the latter one is the most popular method. However, some limitations like imprecise solution process and estimation result of degradation ratio still exist, which may affect the accuracy of the acceleration model and the extrapolation value. Moreover, the conducted solution of this problem, Bayesian method, lose key information when unifying the degradation data. In this paper, a new data processing and parameter inference method based on Bayesian method is proposed to handle degradation data and solve the problems above. First, Wiener process and acceleration model is chosen; Second, the initial values of degradation model and parameters of prior and posterior distribution under each level is calculated with updating and iteration of estimation values; Third, the lifetime and reliability values are estimated on the basis of the estimation parameters; Finally, a case study is provided to demonstrate the validity of the proposed method. The results illustrate that the proposed method is quite effective and accuracy in estimating the lifetime and reliability of a product.

  20. Development of a reliable and clinically useful Italian version of the Axis II for the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD

    Directory of Open Access Journals (Sweden)

    Ludovica Antonella Macrì

    2008-06-01

    Full Text Available

    Background: Multiple-language versions of the same psychometric instrument are increasingly needed, but simply translating an English version word-to-word into another language is not adequate to account for linguistic and cultural differences. Our aim was to alidate an Italian version of the Axis II of the Research Diagnostic Criteria for temporomandibular disorders (RDC/TMD and to test its reproducibility in order to use this important diagnostic instrument in Italian patients.

    Methods: The original English-language version was translated and culturally adapted for Italian-speaking people, back-translated to English and then tested on 68 subjects: 34 TMD patients and 34 healthy subjects. Internal consistency was assessed by calculating the Cronbach coefficient alpha for the entire scale in the two samples. The reproducibility of the domains was assessed with the use of the Spearman-Brown test-retest reliability test, Wilcoxon matched pair test, Sign test and 2x2table Chi Square test according to the data types. Correlation of the initial and test-retest scores of the Axis II was measured with the Spearman rank correlation coefficient as an additional measure of reproducibility.

    Results: The Italian version of Axis II has a good eproducibility; the internal consistency (measured with he Cronbach coefficient alpha of the overall final questionnaire was excellent: 0.95.

    Conclusions: The Axis II Italian version appeared reliable and it could be useful to assess TMD patients and to standardize the data acquisition in this relevant and common disease.

  1. The 2010 American college of rheumatology fibromyalgia survey diagnostic criteria and symptom severity scale is a valid and reliable tool in a French speaking fibromyalgia cohort

    Directory of Open Access Journals (Sweden)

    Fitzcharles Mary-Ann

    2012-09-01

    Full Text Available Abstract Background Fibromyalgia (FM is a pain condition with associated symptoms contributing to distress. The Fibromyalgia Survey Diagnostic Criteria and Severity Scale (FSDC is a patient-administered questionnaire assessing diagnosis and symptom severity. Locations of body pain measured by the Widespread Pain Index (WPI, and the Symptom Severity scale (SS measuring fatigue, unrefreshing sleep, cognitive and somatic complaints provide a score (0–31, measuring a composite of polysymptomatic distress. The reliability and validity of the translated French version of the FSDC was evaluated. Methods The French FSDC was administered twice to 73 FM patients, and was correlated with measures of symptom status including: Fibromyalgia Impact Questionnaire (FIQ, Health Assessment Questionnaire (HAQ, McGill Pain Questionnaire (MPQ, and a visual analogue scale (VAS for global severity and pain. Test-retest reliability, internal consistency, and construct validity were evaluated. Results Test-retest reliability was between .600 and .888 for the 25 single items of the FSDC, and .912 for the total FSDC, with all correlations significant (p  Conclusions The French FSDC is a valid instrument in French FM patients with reliability and construct validity. It is easily completed, simple to score, and has the potential to become the standard for measurement of polysymptomatic distress in FM.

  2. Mathematical Methods in Survival Analysis, Reliability and Quality of Life

    CERN Document Server

    Huber, Catherine; Mesbah, Mounir

    2008-01-01

    Reliability and survival analysis are important applications of stochastic mathematics (probability, statistics and stochastic processes) that are usually covered separately in spite of the similarity of the involved mathematical theory. This title aims to redress this situation: it includes 21 chapters divided into four parts: Survival analysis, Reliability, Quality of life, and Related topics. Many of these chapters were presented at the European Seminar on Mathematical Methods for Survival Analysis, Reliability and Quality of Life in 2006.

  3. A method of predicting the reliability of CDM coil insulation

    International Nuclear Information System (INIS)

    Kytasty, A.; Ogle, C.; Arrendale, H.

    1992-01-01

    This paper presents a method of predicting the reliability of the Collider Dipole Magnet (CDM) coil insulation design. The method proposes a probabilistic treatment of electrical test data, stress analysis, material properties variability and loading uncertainties to give the reliability estimate. The approach taken to predict reliability of design related failure modes of the CDM is to form analytical models of the various possible failure modes and their related mechanisms or causes, and then statistically assess the contributions of the various contributing variables. The probability of the failure mode occurring is interpreted as the number of times one would expect certain extreme situations to combine and randomly occur. One of the more complex failure modes of the CDM will be used to illustrate this methodology

  4. Developing a reliable signal wire attachment method for rail.

    Science.gov (United States)

    2014-11-01

    The goal of this project was to develop a better attachment method for rail signal wires to improve the reliability of signaling : systems. EWI conducted basic research into the failure mode of current attachment methods and developed and tested a ne...

  5. Advancing methods for reliably assessing motivational interviewing fidelity using the motivational interviewing skills code.

    Science.gov (United States)

    Lord, Sarah Peregrine; Can, Doğan; Yi, Michael; Marin, Rebeca; Dunn, Christopher W; Imel, Zac E; Georgiou, Panayiotis; Narayanan, Shrikanth; Steyvers, Mark; Atkins, David C

    2015-02-01

    The current paper presents novel methods for collecting MISC data and accurately assessing reliability of behavior codes at the level of the utterance. The MISC 2.1 was used to rate MI interviews from five randomized trials targeting alcohol and drug use. Sessions were coded at the utterance-level. Utterance-based coding reliability was estimated using three methods and compared to traditional reliability estimates of session tallies. Session-level reliability was generally higher compared to reliability using utterance-based codes, suggesting that typical methods for MISC reliability may be biased. These novel methods in MI fidelity data collection and reliability assessment provided rich data for therapist feedback and further analyses. Beyond implications for fidelity coding, utterance-level coding schemes may elucidate important elements in the counselor-client interaction that could inform theories of change and the practice of MI. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. The Impact of Gas Turbine Component Leakage Fault on GPA Performance Diagnostics

    Directory of Open Access Journals (Sweden)

    E. L. Ntantis

    2016-01-01

    Full Text Available The leakage analysis is a key factor in determining energy loss from a gas turbine. Once the components assembly fails, air leakage through the opening increases resulting in a performance loss. Therefore, the performance efficiency of the engine cannot be reliably determined, without good estimates and analysis of leakage faults. Consequently, the implementation of a leakage fault within a gas turbine engine model is necessary for any performance diagnostic technique that can expand its diagnostics capabilities for more accurate predictions. This paper explores the impact of gas turbine component leakage fault on GPA (Gas Path Analysis Performance Diagnostics. The analysis is demonstrated with a test case where gas turbine performance simulation and diagnostics code TURBOMATCH is used to build a performance model of a model engine similar to Rolls-Royce Trent 500 turbofan engine, and carry out the diagnostic analysis with the presence of different component fault cases. Conclusively, to improve the reliability of the diagnostic results, a leakage fault analysis of the implemented faults is made. The diagnostic tool used to deal with the analysis of the gas turbine component implemented faults is a model-based method utilizing a non-linear GPA.

  7. Diagnostic methods of fatty liver disease

    International Nuclear Information System (INIS)

    Kukuk, Guido Matthias; Sprinkart, Alois Martin; Traeber, Frank

    2017-01-01

    Fatty liver disease is defined as an abnormal accumulation of lipids into the cytoplasm of hepatocytes. Different kinds of fatty liver diseases are becoming the most important etiologies of end-stage liver disease in the western world. Because fatty liver is a theoretically reversible process, timely and accurate diagnosis is a prerequisite for potential therapeutic options. This work describes major diagnostic methods and discusses particular advantages and disadvantages of various techniques.

  8. Reliability analysis for thermal cutting method based non-explosive separation device

    International Nuclear Information System (INIS)

    Choi, Jun Woo; Hwang, Kuk Ha; Kim, Byung Kyu

    2016-01-01

    In order to increase the reliability of a separation device for a small satellite, a new non-explosive separation device is invented. This device is activated using a thermal cutting method with a Ni-Cr wire. A reliability analysis is carried out for the proposed non-explosive separation device by applying the Fault tree analysis (FTA) method. In the FTA results for the separation device, only ten single-point failure modes are found. The reliability modeling and analysis for the device are performed considering failure of the power supply, the Ni-Cr wire burns failure and unwinds, the holder separation failure, the balls separation failure, and the pin release failure. Ultimately, the reliability of the proposed device is calculated as 0.999989 with five Ni-Cr wire coils

  9. Reliability analysis for thermal cutting method based non-explosive separation device

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jun Woo; Hwang, Kuk Ha; Kim, Byung Kyu [Korea Aerospace University, Goyang (Korea, Republic of)

    2016-12-15

    In order to increase the reliability of a separation device for a small satellite, a new non-explosive separation device is invented. This device is activated using a thermal cutting method with a Ni-Cr wire. A reliability analysis is carried out for the proposed non-explosive separation device by applying the Fault tree analysis (FTA) method. In the FTA results for the separation device, only ten single-point failure modes are found. The reliability modeling and analysis for the device are performed considering failure of the power supply, the Ni-Cr wire burns failure and unwinds, the holder separation failure, the balls separation failure, and the pin release failure. Ultimately, the reliability of the proposed device is calculated as 0.999989 with five Ni-Cr wire coils.

  10. On some methods of NPP functional diagnostics

    International Nuclear Information System (INIS)

    Babkin, N.A.

    1988-01-01

    Methods for NPP functional diagnosis, in which space and time dependences for controlled variable anomalous deviations change are used as characteristic features, are suggested. The methods are oriented for operative recognition of suddenly appearing defects and envelop quite a wide range of possible anomalous effects in an onject under diagnostics. Analysis of transients dynamic properties caused by a failure is realized according to the rules, which do not depend on the character of anomalous situation development

  11. Sensorless PV Array Diagnostic Method for Residential PV Systems

    DEFF Research Database (Denmark)

    Sera, Dezso; Spataru, Sergiu; Mathe, Laszlo

    2011-01-01

    This work proposes a temperature and irradiance sensorless diagnostic method suitable for small residential PV installations, focusing on detection of partial shadows. The method works by detection of failures in crystalline silicone PV arrays by concomitant monitoring of some of their key...

  12. Quantitative Methods for Molecular Diagnostic and Therapeutic Imaging

    OpenAIRE

    Li, Quanzheng

    2013-01-01

    This theme issue provides an overview on the basic quantitative methods, an in-depth discussion on the cutting-edge quantitative analysis approaches as well as their applications for both static and dynamic molecular diagnostic and therapeutic imaging.

  13. Molecular diagnostic methods for invasive fungal disease: the horizon draws nearer?

    Science.gov (United States)

    Halliday, C L; Kidd, S E; Sorrell, T C; Chen, S C-A

    2015-04-01

    Rapid, accurate diagnostic laboratory tests are needed to improve clinical outcomes of invasive fungal disease (IFD). Traditional direct microscopy, culture and histological techniques constitute the 'gold standard' against which newer tests are judged. Molecular diagnostic methods, whether broad-range or fungal-specific, have great potential to enhance sensitivity and speed of IFD diagnosis, but have varying specificities. The use of PCR-based assays, DNA sequencing, and other molecular methods including those incorporating proteomic approaches such as matrix-assisted laser desorption ionisation-time of flight mass spectroscopy (MALDI-TOF MS) have shown promising results. These are used mainly to complement conventional methods since they require standardisation before widespread implementation can be recommended. None are incorporated into diagnostic criteria for defining IFD. Commercial assays may assist standardisation. This review provides an update of molecular-based diagnostic approaches applicable to biological specimens and fungal cultures in microbiology laboratories. We focus on the most common pathogens, Candida and Aspergillus, and the mucormycetes. The position of molecular-based approaches in the detection of azole and echinocandin antifungal resistance is also discussed.

  14. An Investment Level Decision Method to Secure Long-term Reliability

    Science.gov (United States)

    Bamba, Satoshi; Yabe, Kuniaki; Seki, Tomomichi; Shibaya, Tetsuji

    The slowdown in power demand increase and facility replacement causes the aging and lower reliability in power facility. And the aging is followed by the rapid increase of repair and replacement when many facilities reach their lifetime in future. This paper describes a method to estimate the repair and replacement costs in future by applying the life-cycle cost model and renewal theory to the historical data. This paper also describes a method to decide the optimum investment plan, which replaces facilities in the order of cost-effectiveness by setting replacement priority formula, and the minimum investment level to keep the reliability. Estimation examples applied to substation facilities show that the reasonable and leveled future cash-out can keep the reliability by lowering the percentage of replacements caused by fatal failures.

  15. A generic method for assignment of reliability scores applied to solvent accessibility predictions

    Directory of Open Access Journals (Sweden)

    Nielsen Morten

    2009-07-01

    Full Text Available Abstract Background Estimation of the reliability of specific real value predictions is nontrivial and the efficacy of this is often questionable. It is important to know if you can trust a given prediction and therefore the best methods associate a prediction with a reliability score or index. For discrete qualitative predictions, the reliability is conventionally estimated as the difference between output scores of selected classes. Such an approach is not feasible for methods that predict a biological feature as a single real value rather than a classification. As a solution to this challenge, we have implemented a method that predicts the relative surface accessibility of an amino acid and simultaneously predicts the reliability for each prediction, in the form of a Z-score. Results An ensemble of artificial neural networks has been trained on a set of experimentally solved protein structures to predict the relative exposure of the amino acids. The method assigns a reliability score to each surface accessibility prediction as an inherent part of the training process. This is in contrast to the most commonly used procedures where reliabilities are obtained by post-processing the output. Conclusion The performance of the neural networks was evaluated on a commonly used set of sequences known as the CB513 set. An overall Pearson's correlation coefficient of 0.72 was obtained, which is comparable to the performance of the currently best public available method, Real-SPINE. Both methods associate a reliability score with the individual predictions. However, our implementation of reliability scores in the form of a Z-score is shown to be the more informative measure for discriminating good predictions from bad ones in the entire range from completely buried to fully exposed amino acids. This is evident when comparing the Pearson's correlation coefficient for the upper 20% of predictions sorted according to reliability. For this subset, values of 0

  16. Bearing Procurement Analysis Method by Total Cost of Ownership Analysis and Reliability Prediction

    Science.gov (United States)

    Trusaji, Wildan; Akbar, Muhammad; Sukoyo; Irianto, Dradjad

    2018-03-01

    In making bearing procurement analysis, price and its reliability must be considered as decision criteria, since price determines the direct cost as acquisition cost and reliability of bearing determine the indirect cost such as maintenance cost. Despite the indirect cost is hard to identify and measured, it has high contribution to overall cost that will be incurred. So, the indirect cost of reliability must be considered when making bearing procurement analysis. This paper tries to explain bearing evaluation method with the total cost of ownership analysis to consider price and maintenance cost as decision criteria. Furthermore, since there is a lack of failure data when bearing evaluation phase is conducted, reliability prediction method is used to predict bearing reliability from its dynamic load rating parameter. With this method, bearing with a higher price but has higher reliability is preferable for long-term planning. But for short-term planning the cheaper one but has lower reliability is preferable. This contextuality can give rise to conflict between stakeholders. Thus, the planning horizon needs to be agreed by all stakeholder before making a procurement decision.

  17. Minimal methylation classifier (MIMIC): A novel method for derivation and rapid diagnostic detection of disease-associated DNA methylation signatures.

    Science.gov (United States)

    Schwalbe, E C; Hicks, D; Rafiee, G; Bashton, M; Gohlke, H; Enshaei, A; Potluri, S; Matthiesen, J; Mather, M; Taleongpong, P; Chaston, R; Silmon, A; Curtis, A; Lindsey, J C; Crosier, S; Smith, A J; Goschzik, T; Doz, F; Rutkowski, S; Lannering, B; Pietsch, T; Bailey, S; Williamson, D; Clifford, S C

    2017-10-18

    Rapid and reliable detection of disease-associated DNA methylation patterns has major potential to advance molecular diagnostics and underpin research investigations. We describe the development and validation of minimal methylation classifier (MIMIC), combining CpG signature design from genome-wide datasets, multiplex-PCR and detection by single-base extension and MALDI-TOF mass spectrometry, in a novel method to assess multi-locus DNA methylation profiles within routine clinically-applicable assays. We illustrate the application of MIMIC to successfully identify the methylation-dependent diagnostic molecular subgroups of medulloblastoma (the most common malignant childhood brain tumour), using scant/low-quality samples remaining from the most recently completed pan-European medulloblastoma clinical trial, refractory to analysis by conventional genome-wide DNA methylation analysis. Using this approach, we identify critical DNA methylation patterns from previously inaccessible cohorts, and reveal novel survival differences between the medulloblastoma disease subgroups with significant potential for clinical exploitation.

  18. Development, reliability, and validity of the Posttraumatic Stress Disorder Interview for Vietnamese refugees: a diagnostic instrument for Vietnamese refugees.

    Science.gov (United States)

    Dao, Tam K; Poritz, Julia M P; Moody, Rachel P; Szeto, Kim

    2012-08-01

    The Posttraumatic Stress Disorder Interview for Vietnamese Refugees (PTSD-IVR) was created specifically to assess for the presence of current and lifetime history of premigration, migration, encampment, and postmigration traumas in Vietnamese refugees. The purpose of the present study was to describe the development of and investigate the interrater and test-retest reliability of the PTSD-IVR and its validity in relation to the diagnoses obtained from the Longitudinal, Expert, and All Data (LEAD; Spitzer, 1983) standard. Clinicians conducted the diagnosis process with 127 Vietnamese refugees using the LEAD standard and the PTSD-IVR. Assessment of the reliability and validity of the PTSD-IVR yielded good to excellent AUC (area under the receiver operating characteristic curve; .86, .87) and κ values (.66, .74) indicating the reliability of the PTSD-IVR and the agreement between the LEAD procedure and the PTSD-IVR. The results of the present study suggest that the PTSD-IVR performs successfully as a diagnostic instrument specifically created for Vietnamese refugees in their native language. Copyright © 2012 International Society for Traumatic Stress Studies.

  19. Diagnostic methods for dental caries used by private dental ...

    African Journals Online (AJOL)

    Objectives: This study aimed to investigate the preference profiles of various types of diagnostic tools and methods used by private dental practitioners in Ankara for detecting dental caries. Methods: Private dental practitioners, in five districts of Ankara, were provided with questionnaires comprising demographic ...

  20. The Reliability, Impact, and Cost-Effectiveness of Value-Added Teacher Assessment Methods

    Science.gov (United States)

    Yeh, Stuart S.

    2012-01-01

    This article reviews evidence regarding the intertemporal reliability of teacher rankings based on value-added methods. Value-added methods exhibit low reliability, yet are broadly supported by prominent educational researchers and are increasingly being used to evaluate and fire teachers. The article then presents a cost-effectiveness analysis…

  1. Lectin-induced agglutination method of urinary exosomes isolation followed by mi-RNA analysis: Application for prostate cancer diagnostic.

    Science.gov (United States)

    Samsonov, Roman; Shtam, Tatiana; Burdakov, Vladimir; Glotov, Andrey; Tsyrlina, Evgenia; Berstein, Lev; Nosov, Alexander; Evtushenko, Vladimir; Filatov, Michael; Malek, Anastasia

    2016-01-01

    Prostate cancer is the most common cancer in men. Prostate-specific antigen has, however, insufficient diagnostic specificity. Novel complementary diagnostic approaches are greatly needed. MiRNAs are small regulatory RNAs which play an important role in tumorogenesis and are being investigated as a cancer biomarker. In addition to their intracellular regulatory functions, miRNAs are secreted into the extracellular space and can be found in various body fluids, including urine. The stability of extracellular miRNAs is defined by association with proteins, lipoprotein particles, and membrane vesicles. Among the known forms of miRNA packaging, tumour-derived exosome-enclosed miRNAs is thought to reflect the vital activity of cancer cells. The assessment of the exosomal fraction of urinary miRNA may present a new and highly specific method for prostate cancer diagnostics; however, this is challenged by the absence of reliable and inexpensive methods for isolation of exosomes. Prostate cancer (PC) cell lines and urine samples collected from 35 PC patients and 35 healthy donors were used in the study. Lectins, phytohemagglutinin, and concanavalin A were used to induce agglutination of exosomes. The efficiency of isolation process was evaluated by AFM and DLS assays. The protein content of isolated exosomes was analysed by western blotting. Exosomal RNA was assayed by automated electrophoresis and expression level of selected miRNAs was evaluated by RT-qPCR. The diagnostic potency of the urinary exosomal miRNA assessment was estimated by the ROC method. The formation of multi-vesicular agglutinates in urine can be induced by incubation with lectin at a final concentration of 2 mg/ml. These agglutinates contain urinary exosomes and may be pelleted by centrifugation with a relatively low G-force. The analysis of PC-related miRNA in urinary exosomes revealed significant up-regulation of miR-574-3p, miR-141-5p, and miR-21-5p associated with PC. Lectin-induced aggregation is a

  2. Reliability of a semi-quantitative method for dermal exposure assessment (DREAM)

    NARCIS (Netherlands)

    Wendel de Joode, B. van; Hemmen, J.J. van; Meijster, T.; Major, V.; London, L.; Kromhout, H.

    2005-01-01

    Valid and reliable semi-quantitative dermal exposure assessment methods for epidemiological research and for occupational hygiene practice, applicable for different chemical agents, are practically nonexistent. The aim of this study was to assess the reliability of a recently developed

  3. Design Optimization Method for Composite Components Based on Moment Reliability-Sensitivity Criteria

    Science.gov (United States)

    Sun, Zhigang; Wang, Changxi; Niu, Xuming; Song, Yingdong

    2017-08-01

    In this paper, a Reliability-Sensitivity Based Design Optimization (RSBDO) methodology for the design of the ceramic matrix composites (CMCs) components has been proposed. A practical and efficient method for reliability analysis and sensitivity analysis of complex components with arbitrary distribution parameters are investigated by using the perturbation method, the respond surface method, the Edgeworth series and the sensitivity analysis approach. The RSBDO methodology is then established by incorporating sensitivity calculation model into RBDO methodology. Finally, the proposed RSBDO methodology is applied to the design of the CMCs components. By comparing with Monte Carlo simulation, the numerical results demonstrate that the proposed methodology provides an accurate, convergent and computationally efficient method for reliability-analysis based finite element modeling engineering practice.

  4. ICT diagnostic method of beryllium welding quality

    International Nuclear Information System (INIS)

    Sun Lingxia; Wei Kentang; Ye Yunchang

    2002-01-01

    To avoid the interference of high density material for the quality assay of beryllium welding line, a slice by slice scanning method was proposed based upon the research results of the Industrial Computerized Tomography (ICT) diagnostics for weld penetration, weld width, off-centered deviation and weld defects of beryllium-ring welding seam with high density material inside

  5. System reliability with correlated components: Accuracy of the Equivalent Planes method

    NARCIS (Netherlands)

    Roscoe, K.; Diermanse, F.; Vrouwenvelder, A.C.W.M.

    2015-01-01

    Computing system reliability when system components are correlated presents a challenge because it usually requires solving multi-fold integrals numerically, which is generally infeasible due to the computational cost. In Dutch flood defense reliability modeling, an efficient method for computing

  6. System reliability with correlated components : Accuracy of the Equivalent Planes method

    NARCIS (Netherlands)

    Roscoe, K.; Diermanse, F.; Vrouwenvelder, T.

    2015-01-01

    Computing system reliability when system components are correlated presents a challenge because it usually requires solving multi-fold integrals numerically, which is generally infeasible due to the computational cost. In Dutch flood defense reliability modeling, an efficient method for computing

  7. Reliability and validity of the AutoCAD software method in lumbar lordosis measurement.

    Science.gov (United States)

    Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe

    2011-12-01

    The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis.

  8. The effectiveness of diagnostic imaging methods for the assessment of soft tissue and articular disorders of the shoulder and elbow

    Energy Technology Data Exchange (ETDEWEB)

    Shahabpour, M. [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: Maryam@shahabpour.uzbrussel; Kichouh, M.; Laridon, E. [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium); Gielen, J.L. [Department of Radiology, Universitair Ziekenhuis Antwerpen, Universiteit Antwerpen, Wilrijkstraat 10, 2650 Edegem (Belgium); De Mey, J. [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)

    2008-02-15

    There are no clear guidelines for diagnostic imaging of articular and soft tissue pathologies of the shoulder and elbow. Several methods are used, including magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and ultrasound (US). Their cost-effectiveness is still unclear. We performed a meta-analysis of the relevant literature and discussed the role of MR imaging of the shoulder and elbow compared with other diagnostic imaging modalities. For the shoulder impingement syndrome and rotator cuff tears, MRI and US have a comparable accuracy for detection of full-thickness rotator cuff tears. MRA and US might be more accurate for the detection of partial-thickness tears than MRI. Given the large difference in cost of MR and US, ultrasound may be the most cost-effective diagnostic method for identification of full-thickness tears in a specialist hospital setting (Evidence level 3). Both MRA and CT arthrography (CTA) are effective methods for the detection of labrum tears. More recently, multidetector CTA has offered the advantages of thinner slices than with MRA in a shorter examination time. Still, MRA has the advantage towards CTA to directly visualize the affected structures with a better evaluation of extent and location and to detect associated capsuloligamentous injuries. For the elbow pathologies, plain MRI or MRA have the advantage towards CTA to detect occult bone injuries. CTA is better for the assessment of the thin cartilage of the elbow. Both US and MRI are reliable methods to detect chronic epicondylitis; US is more available and far more cost-effective (Evidence level 2). MRA can differentiate complete from partial tears of the medial collateral ligament. US or MRI can detect partial and complete biceps tendon tears and/or bursitis. MRI can provide important diagnostic information in lesions of the ulnar, radial, or median nerve.

  9. Selected Methods For Increases Reliability The Of Electronic Systems Security

    Directory of Open Access Journals (Sweden)

    Paś Jacek

    2015-11-01

    Full Text Available The article presents the issues related to the different methods to increase the reliability of electronic security systems (ESS for example, a fire alarm system (SSP. Reliability of the SSP in the descriptive sense is a property preservation capacity to implement the preset function (e.g. protection: fire airport, the port, logistics base, etc., at a certain time and under certain conditions, e.g. Environmental, despite the possible non-compliance by a specific subset of elements this system. Analyzing the available literature on the ESS-SSP is not available studies on methods to increase the reliability (several works similar topics but moving with respect to the burglary and robbery (Intrusion. Based on the analysis of the set of all paths in the system suitability of the SSP for the scenario mentioned elements fire events (device critical because of security.

  10. Structural Reliability Using Probability Density Estimation Methods Within NESSUS

    Science.gov (United States)

    Chamis, Chrisos C. (Technical Monitor); Godines, Cody Ric

    2003-01-01

    A reliability analysis studies a mathematical model of a physical system taking into account uncertainties of design variables and common results are estimations of a response density, which also implies estimations of its parameters. Some common density parameters include the mean value, the standard deviation, and specific percentile(s) of the response, which are measures of central tendency, variation, and probability regions, respectively. Reliability analyses are important since the results can lead to different designs by calculating the probability of observing safe responses in each of the proposed designs. All of this is done at the expense of added computational time as compared to a single deterministic analysis which will result in one value of the response out of many that make up the density of the response. Sampling methods, such as monte carlo (MC) and latin hypercube sampling (LHS), can be used to perform reliability analyses and can compute nonlinear response density parameters even if the response is dependent on many random variables. Hence, both methods are very robust; however, they are computationally expensive to use in the estimation of the response density parameters. Both methods are 2 of 13 stochastic methods that are contained within the Numerical Evaluation of Stochastic Structures Under Stress (NESSUS) program. NESSUS is a probabilistic finite element analysis (FEA) program that was developed through funding from NASA Glenn Research Center (GRC). It has the additional capability of being linked to other analysis programs; therefore, probabilistic fluid dynamics, fracture mechanics, and heat transfer are only a few of what is possible with this software. The LHS method is the newest addition to the stochastic methods within NESSUS. Part of this work was to enhance NESSUS with the LHS method. The new LHS module is complete, has been successfully integrated with NESSUS, and been used to study four different test cases that have been

  11. New method of leak detecting in diagnostic of gas pipeline system

    International Nuclear Information System (INIS)

    Kalinowski, K.; Dabrowski, A.; Sobkiewicz, D.; Oracz, H.

    2007-01-01

    This report describes new directions in gas transmission pipelines diagnostics as well as new methods and equipment used to detect leaks. It was also shown that efficient and functional diagnostics system is the necessary condition to keep the exploitation of transmission systems safe. (author)

  12. [METHODS OF MATHEMATICAL MODELING IN MORPHOLOGICAL DIAGNOSTICS OF CHORNOBYL FACTOR INFLUENCE ON PROSTATE GLAND OF COAL MINERS-- THE CHERNOBYL DISASTER FIGHTERS].

    Science.gov (United States)

    Danylov, Iu V; Motkov, K V; Shevchenko, T I

    2014-01-01

    The morphometric estimation of parenchyma and stroma condition included the determination of 25 parameters in a prostate gland at 27 persons. The mathematical model of morphogenesis of prostate gland was created by Bayes' method. The method of differential diagnosis of a prostate gland tissues' changes conditioned by the influence of the Chernobyl factor and/or unfavorable terms of the work in underground coal mines have been worked out. Its practical use provides exactness and reliability of the diagnosis (not less than 95%), independence from the level of the qualification and personal experience of the doctor, allows us to unify, optimize and individualize the diagnostic algorithms, answer the requirements of evidential medicine.

  13. NEURAL NETWORK SYSTEM FOR DIAGNOSTICS OF AVIATION DESIGNATION PRODUCTS

    Directory of Open Access Journals (Sweden)

    В. Єременко

    2011-02-01

    Full Text Available In the article for solving the classification problem of the technical state of the  object, proposed to use a hybrid neural network with a Kohonen layer and multilayer perceptron. The information-measuring system can be used for standardless diagnostics, cluster analysis and to classify the products which made from composite materials. The advantage of this architecture is flexibility, high performance, ability to use different methods for collecting diagnostic information about unit under test, high reliability of information processing

  14. Issues in benchmarking human reliability analysis methods: A literature review

    International Nuclear Information System (INIS)

    Boring, Ronald L.; Hendrickson, Stacey M.L.; Forester, John A.; Tran, Tuan Q.; Lois, Erasmia

    2010-01-01

    There is a diversity of human reliability analysis (HRA) methods available for use in assessing human performance within probabilistic risk assessments (PRA). Due to the significant differences in the methods, including the scope, approach, and underlying models, there is a need for an empirical comparison investigating the validity and reliability of the methods. To accomplish this empirical comparison, a benchmarking study comparing and evaluating HRA methods in assessing operator performance in simulator experiments is currently underway. In order to account for as many effects as possible in the construction of this benchmarking study, a literature review was conducted, reviewing past benchmarking studies in the areas of psychology and risk assessment. A number of lessons learned through these studies is presented in order to aid in the design of future HRA benchmarking endeavors.

  15. Issues in benchmarking human reliability analysis methods : a literature review.

    Energy Technology Data Exchange (ETDEWEB)

    Lois, Erasmia (US Nuclear Regulatory Commission); Forester, John Alan; Tran, Tuan Q. (Idaho National Laboratory, Idaho Falls, ID); Hendrickson, Stacey M. Langfitt; Boring, Ronald L. (Idaho National Laboratory, Idaho Falls, ID)

    2008-04-01

    There is a diversity of human reliability analysis (HRA) methods available for use in assessing human performance within probabilistic risk assessment (PRA). Due to the significant differences in the methods, including the scope, approach, and underlying models, there is a need for an empirical comparison investigating the validity and reliability of the methods. To accomplish this empirical comparison, a benchmarking study is currently underway that compares HRA methods with each other and against operator performance in simulator studies. In order to account for as many effects as possible in the construction of this benchmarking study, a literature review was conducted, reviewing past benchmarking studies in the areas of psychology and risk assessment. A number of lessons learned through these studies are presented in order to aid in the design of future HRA benchmarking endeavors.

  16. Evaluation of Information Requirements of Reliability Methods in Engineering Design

    DEFF Research Database (Denmark)

    Marini, Vinicius Kaster; Restrepo-Giraldo, John Dairo; Ahmed-Kristensen, Saeema

    2010-01-01

    This paper aims to characterize the information needed to perform methods for robustness and reliability, and verify their applicability to early design stages. Several methods were evaluated on their support to synthesis in engineering design. Of those methods, FMEA, FTA and HAZOP were selected...

  17. Neural network analysis of vibration signals in the diagnostics of ...

    African Journals Online (AJOL)

    The article is devoted to the improvement of heat network calculation and diagnostics methods. Currently used instruments have many shortcomings for the diagnosis of pipelines, including low reliability of defect detection and subjective decision-making. The authors created an experimental stand, which allows to conduct ...

  18. A generic method for estimating system reliability using Bayesian networks

    International Nuclear Information System (INIS)

    Doguc, Ozge; Ramirez-Marquez, Jose Emmanuel

    2009-01-01

    This study presents a holistic method for constructing a Bayesian network (BN) model for estimating system reliability. BN is a probabilistic approach that is used to model and predict the behavior of a system based on observed stochastic events. The BN model is a directed acyclic graph (DAG) where the nodes represent system components and arcs represent relationships among them. Although recent studies on using BN for estimating system reliability have been proposed, they are based on the assumption that a pre-built BN has been designed to represent the system. In these studies, the task of building the BN is typically left to a group of specialists who are BN and domain experts. The BN experts should learn about the domain before building the BN, which is generally very time consuming and may lead to incorrect deductions. As there are no existing studies to eliminate the need for a human expert in the process of system reliability estimation, this paper introduces a method that uses historical data about the system to be modeled as a BN and provides efficient techniques for automated construction of the BN model, and hence estimation of the system reliability. In this respect K2, a data mining algorithm, is used for finding associations between system components, and thus building the BN model. This algorithm uses a heuristic to provide efficient and accurate results while searching for associations. Moreover, no human intervention is necessary during the process of BN construction and reliability estimation. The paper provides a step-by-step illustration of the method and evaluation of the approach with literature case examples

  19. A generic method for estimating system reliability using Bayesian networks

    Energy Technology Data Exchange (ETDEWEB)

    Doguc, Ozge [Stevens Institute of Technology, Hoboken, NJ 07030 (United States); Ramirez-Marquez, Jose Emmanuel [Stevens Institute of Technology, Hoboken, NJ 07030 (United States)], E-mail: jmarquez@stevens.edu

    2009-02-15

    This study presents a holistic method for constructing a Bayesian network (BN) model for estimating system reliability. BN is a probabilistic approach that is used to model and predict the behavior of a system based on observed stochastic events. The BN model is a directed acyclic graph (DAG) where the nodes represent system components and arcs represent relationships among them. Although recent studies on using BN for estimating system reliability have been proposed, they are based on the assumption that a pre-built BN has been designed to represent the system. In these studies, the task of building the BN is typically left to a group of specialists who are BN and domain experts. The BN experts should learn about the domain before building the BN, which is generally very time consuming and may lead to incorrect deductions. As there are no existing studies to eliminate the need for a human expert in the process of system reliability estimation, this paper introduces a method that uses historical data about the system to be modeled as a BN and provides efficient techniques for automated construction of the BN model, and hence estimation of the system reliability. In this respect K2, a data mining algorithm, is used for finding associations between system components, and thus building the BN model. This algorithm uses a heuristic to provide efficient and accurate results while searching for associations. Moreover, no human intervention is necessary during the process of BN construction and reliability estimation. The paper provides a step-by-step illustration of the method and evaluation of the approach with literature case examples.

  20. Research on Control Method Based on Real-Time Operational Reliability Evaluation for Space Manipulator

    Directory of Open Access Journals (Sweden)

    Yifan Wang

    2014-05-01

    Full Text Available A control method based on real-time operational reliability evaluation for space manipulator is presented for improving the success rate of a manipulator during the execution of a task. In this paper, a method for quantitative analysis of operational reliability is given when manipulator is executing a specified task; then a control model which could control the quantitative operational reliability is built. First, the control process is described by using a state space equation. Second, process parameters are estimated in real time using Bayesian method. Third, the expression of the system's real-time operational reliability is deduced based on the state space equation and process parameters which are estimated using Bayesian method. Finally, a control variable regulation strategy which considers the cost of control is given based on the Theory of Statistical Process Control. It is shown via simulations that this method effectively improves the operational reliability of space manipulator control system.

  1. Study of Fuze Structure and Reliability Design Based on the Direct Search Method

    Science.gov (United States)

    Lin, Zhang; Ning, Wang

    2017-03-01

    Redundant design is one of the important methods to improve the reliability of the system, but mutual coupling of multiple factors is often involved in the design. In my study, Direct Search Method is introduced into the optimum redundancy configuration for design optimization, in which, the reliability, cost, structural weight and other factors can be taken into account simultaneously, and the redundant allocation and reliability design of aircraft critical system are computed. The results show that this method is convenient and workable, and applicable to the redundancy configurations and optimization of various designs upon appropriate modifications. And this method has a good practical value.

  2. Test-Retest Reliability of the Preschool Age Psychiatric Assessment (PAPA)

    Science.gov (United States)

    Egger, Helen Link; Erkanli, Alaattin; Keeler, Gordon; Potts, Edward; Walter, Barbara Keith; Angold, Adrian

    2006-01-01

    Objective: To examine the test-retest reliability of a new interviewer-based psychiatric diagnostic measure (the Preschool Age Psychiatric Assessment) for use with parents of preschoolers 2 to 5 years old. Method: A total of 1,073 parents of children attending a large pediatric clinic completed the Child Behavior Checklist 1 1/2-5. For 18 months,…

  3. An automated method for estimating reliability of grid systems using Bayesian networks

    International Nuclear Information System (INIS)

    Doguc, Ozge; Emmanuel Ramirez-Marquez, Jose

    2012-01-01

    Grid computing has become relevant due to its applications to large-scale resource sharing, wide-area information transfer, and multi-institutional collaborating. In general, in grid computing a service requests the use of a set of resources, available in a grid, to complete certain tasks. Although analysis tools and techniques for these types of systems have been studied, grid reliability analysis is generally computation-intensive to obtain due to the complexity of the system. Moreover, conventional reliability models have some common assumptions that cannot be applied to the grid systems. Therefore, new analytical methods are needed for effective and accurate assessment of grid reliability. This study presents a new method for estimating grid service reliability, which does not require prior knowledge about the grid system structure unlike the previous studies. Moreover, the proposed method does not rely on any assumptions about the link and node failure rates. This approach is based on a data-mining algorithm, the K2, to discover the grid system structure from raw historical system data, that allows to find minimum resource spanning trees (MRST) within the grid then, uses Bayesian networks (BN) to model the MRST and estimate grid service reliability.

  4. APPLICATION OF MRI IN THE DIAGNOSTICS OF M. MASSETER

    Directory of Open Access Journals (Sweden)

    Mariana Dimova-Gabrovska

    2017-06-01

    Full Text Available Magnetic resonance imaging (MRI is a non-invasive diagnostic method which can provide detailed images of organs and structures of the human body. The purpose of this review is to explore and introduce the diagnostic capabilities of MRI in imaging m. masseter in conditions of norm and pathology. The material of the review is information of 20 literary sources selected from 530, found by keywordsfromJanuary to April 2017. The information about MRI imaging of the normal anatomy of m. masseter and the most common findings in muscle - muscle hypertrophy, inflammatory changes, vascular malformations, intramuscular hemangioma, cysticercosis and changes after radiotherapy was analyzed. In conclusion, the diagnostic capabilities of MRI of masseter muscle – both in the conditions of norm and pathology were confirmed. The method is considered to be reliable, objective, non-invasive and accurate.

  5. Vibrational methods of the overhead gas-pipelines technological equipment diagnostics

    International Nuclear Information System (INIS)

    Zakhezin, A.M.; Malysheva, T.V.

    2001-01-01

    The diagnostic methods of overhead gas-pipelines of the technical equipment of gas-compressor station are considered in this article by carrying out registration certification documentation. Some faults of overhead technical gas-pipelines have been proposed. This paper is devoted to the diagnostic methods of the whole gas- pipelines and their parts for some faults during expert checking fulfillment and carrying out registration certification documentation. The analysis of all defects allows to determine a 'between-repairs interval', to develop some operations to avoid these faults and to estimate the repair operation quality, to reduce failure probability. As an example of the effectiveness of technical condition service of vibrational methods by expertise fulfillment have been considered for some defects of the overhead pipelines. (author)

  6. Diagnostic nerve ultrasonography; Diagnostische Nervensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Baeumer, T. [Universitaet zu Luebeck CBBM, Haus 66, Institut fuer Neurogenetik, Luebeck (Germany); Grimm, A. [Universitaetsklinikum Tuebingen, Klinik und Poliklinik fuer Neurologie, Tuebingen (Germany); Schelle, T. [Staedtisches Klinikum Dessau, Neurologische Klinik, Dessau (Germany)

    2017-03-15

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [German] Fuer die Diagnostik von Nervenlaesionen ist ein bildgebendes Verfahren zur Darstellung des peripheren Nervs und seiner ihn umgebenden Strukturen fuer eine aetiologische Einordnung erforderlich. Mit der klinisch-neurologischen Untersuchung und Elektrophysiologie ist eine funktionelle Aussage ueber die Nervenlaesion moeglich. In der Standard-MRT-Untersuchung wird der periphere Nerv nur unzureichend gut dargestellt. Die MRT-Neurographie ist ein sehr gutes, aber auch zeit- und ressourcenintensives Verfahren. Nutzung des Ultraschalls fuer die

  7. Thyroid nodular disease: their usefulness of diagnostic methods

    International Nuclear Information System (INIS)

    Mendez Ayala, Irene Maria; Sanchez Luthard, Maria de los Angeles; Martins Schmitz; Gomez, Silvia

    2009-01-01

    The thyroid nodular disease is defined by the presence of nodules of thyroid of solid, liquid or mixed consistency, they are or non concrete. Solitary nodule thyroid, diffuse and multinodular goiter forms can be presented in. The thyroid nodule is a frequent clinical problem, the clinical prevalence in adult population is of 4%. Objective: to make a bibliographical revision to near the utility of the different methods available for the thyroid nodular pathology diagnosis and determining which of them turns out more specific to differentiate benignancy from malignancy in the found nodules. Materials and Methods: the bibliographical search was made in the data base Medline (Pubmed), in scientific magazines of the region and text books. Criteria of inclusion: bibliographical references pertaining to medical magazines and free full text with an antiquity nongreater to 8 years were included. Conclusion: the presence of thyroid nodules constitutes a reason for frequent consultation, the main diagnostic method at the moment is the fine needle aspiration cytology, due to its simple accomplishment, low cost, not requiring the hospitalization of the patient, and being fundamental in the decision making of the doctor. This diagnostic method is, in addition, the one that with greater certainty allows to differentiate benign from malignant nodules. (authors) [es

  8. Extended block diagram method for a multi-state system reliability assessment

    International Nuclear Information System (INIS)

    Lisnianski, Anatoly

    2007-01-01

    The presented method extends the classical reliability block diagram method to a repairable multi-state system. It is very suitable for engineering applications since the procedure is well formalized and based on the natural decomposition of the entire multi-state system (the system is represented as a collection of its elements). Until now, the classical block diagram method did not provide the reliability assessment for the repairable multi-state system. The straightforward stochastic process methods are very difficult for engineering application in such cases due to the 'dimension damnation'-huge number of system states. The suggested method is based on the combined random processes and the universal generating function technique and drastically reduces the number of states in the multi-state model

  9. Technology Issues of Burning Plasma Diagnostics

    International Nuclear Information System (INIS)

    Kaye, A. S.

    2008-01-01

    The ITER Tokamak will require many diagnostics both for safe and reliable operation of the machine and for understanding of the physics underlying the performance. The design of these diagnostics raises many challenging technical issues not faced on smaller machines. These arise partly from the increase demands on established diagnostics arising from the increased size, higher magnetic field, large heating power, and in particular the dramatically longer pulse duration of ITER, which make issue such as power loading on first wall components more challenging. The demands on reliability and availability of the machine in order to achieve the objectives within the agreed time schedule also place severe additional demands on the design, quality assurance and maintainability of diagnostics. ITER will produce many orders of magnitude more neutrons than previous Tokamaks and will be a licensed nuclear facility. This has important implications for the traceability, quality assurance and availability of safety critical diagnostics, and for the control of the design and procurement of all diagnostics. The high neutron flux/fluence also constrains the design of diagnostics, which must offer shielding consistent with the allowable dose rates on critical components of the Tokamak, and themselves be tolerant of the radiation level at the diagnostic. This paper presents an overview of the more critical issues for ITER diagnostics

  10. Human reliability analysis during PSA at Trillo NPP: main characteristics and analysis of diagnostic errors

    International Nuclear Information System (INIS)

    Barquin, M.A.; Gomez, F.

    1998-01-01

    The design difference between Trillo NPP and other Spanish nuclear power plants (basic Westinghouse and General Electric designs) were made clear in the Human Reliability Analysis of the Probabilistic Safety Analysis (PSA) for Trillo NPP. The object of this paper is to describe the most significant characteristics of the Human Reliability Analysis carried out in the PSA, with special emphasis on the possible diagnostic errors and their consequences, based on the characteristics in the Emergency Operations Manual for Trillo NPP. - In the case of human errors before the initiating event (type 1), the existence of four redundancies in most of the plant safety systems, means that the impact of this type or error on the final results of the PSA is insignificant. However, in the case common cause errors, especially in certain calibration errors, some actions are significant in the final equation for core damage - The number of human actions that the operator has to carry out during the accidents (type 3) modelled, is relatively small in comparison with this value in other PSAs. This is basically due to the high level of automation at Rillo NPP - The Plant Operations Manual cannot be strictly considered to be a symptoms-based procedure. The operation Group must select the chapter from the Operations Manual to be followed, after having diagnosed the perturbing event, using for this purpose and Emergency and Anomaly Decision Tree (M.O.3.0.1) based on the different indications, alarms and symptoms present in the plant after the perturbing event. For this reason, it was decided to analyse the possible diagnosis errors. In the bibliography on diagnosis and commission errors available at the present time, there is no precise methodology for the analysis of this type of error and its incorporation into PSAs. The method used in the PSA for Trillo y NPP to evaluate this type of interaction, is to develop a Diagnosis Error Table, the object of which is to identify the situations in

  11. Risk-based methods for reliability investments in electric power distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Alvehag, Karin

    2011-07-01

    Society relies more and more on a continuous supply of electricity. However, while under investments in reliability lead to an unacceptable number of power interruptions, over investments result in too high costs for society. To give incentives for a socio economically optimal level of reliability, quality regulations have been adopted in many European countries. These quality regulations imply new financial risks for the distribution system operator (DSO) since poor reliability can reduce the allowed revenue for the DSO and compensation may have to be paid to affected customers. This thesis develops a method for evaluating the incentives for reliability investments implied by different quality regulation designs. The method can be used to investigate whether socio economically beneficial projects are also beneficial for a profit-maximizing DSO subject to a particular quality regulation design. To investigate which reinvestment projects are preferable for society and a DSO, risk-based methods are developed. With these methods, the probability of power interruptions and the consequences of these can be simulated. The consequences of interruptions for the DSO will to a large extent depend on the quality regulation. The consequences for the customers, and hence also society, will depend on factors such as the interruption duration and time of occurrence. The proposed risk-based methods consider extreme outage events in the risk assessments by incorporating the impact of severe weather, estimating the full probability distribution of the total reliability cost, and formulating a risk-averse strategy. Results from case studies performed show that quality regulation design has a significant impact on reinvestment project profitability for a DSO. In order to adequately capture the financial risk that the DSO is exposed to, detailed riskbased methods, such as the ones developed in this thesis, are needed. Furthermore, when making investment decisions, a risk

  12. The Monte Carlo Simulation Method for System Reliability and Risk Analysis

    CERN Document Server

    Zio, Enrico

    2013-01-01

    Monte Carlo simulation is one of the best tools for performing realistic analysis of complex systems as it allows most of the limiting assumptions on system behavior to be relaxed. The Monte Carlo Simulation Method for System Reliability and Risk Analysis comprehensively illustrates the Monte Carlo simulation method and its application to reliability and system engineering. Readers are given a sound understanding of the fundamentals of Monte Carlo sampling and simulation and its application for realistic system modeling.   Whilst many of the topics rely on a high-level understanding of calculus, probability and statistics, simple academic examples will be provided in support to the explanation of the theoretical foundations to facilitate comprehension of the subject matter. Case studies will be introduced to provide the practical value of the most advanced techniques.   This detailed approach makes The Monte Carlo Simulation Method for System Reliability and Risk Analysis a key reference for senior undergra...

  13. Research Review: Test-retest reliability of standardized diagnostic interviews to assess child and adolescent psychiatric disorders: a systematic review and meta-analysis.

    Science.gov (United States)

    Duncan, Laura; Comeau, Jinette; Wang, Li; Vitoroulis, Irene; Boyle, Michael H; Bennett, Kathryn

    2018-02-19

    A better understanding of factors contributing to the observed variability in estimates of test-retest reliability in published studies on standardized diagnostic interviews (SDI) is needed. The objectives of this systematic review and meta-analysis were to estimate the pooled test-retest reliability for parent and youth assessments of seven common disorders, and to examine sources of between-study heterogeneity in reliability. Following a systematic review of the literature, multilevel random effects meta-analyses were used to analyse 202 reliability estimates (Cohen's kappa = ҡ) from 31 eligible studies and 5,369 assessments of 3,344 children and youth. Pooled reliability was moderate at ҡ = .58 (CI 95% 0.53-0.63) and between-study heterogeneity was substantial (Q = 2,063 (df = 201), p reliability varied across informants for specific types of psychiatric disorder (ҡ = .53-.69 for parent vs. ҡ = .39-.68 for youth) with estimates significantly higher for parents on attention deficit hyperactivity disorder, oppositional defiant disorder and the broad groupings of externalizing and any disorder. Reliability was also significantly higher in studies with indicators of poor or fair study methodology quality (sample size reliability of SDIs and the usefulness of these tools in both clinical and research contexts. Potential remedies include the introduction of standardized study and reporting requirements for reliability studies, and exploration of other approaches to assessing and classifying child and adolescent psychiatric disorder. © 2018 Association for Child and Adolescent Mental Health.

  14. Reliability and validity of non-radiographic methods of thoracic kyphosis measurement: a systematic review.

    Science.gov (United States)

    Barrett, Eva; McCreesh, Karen; Lewis, Jeremy

    2014-02-01

    A wide array of instruments are available for non-invasive thoracic kyphosis measurement. Guidelines for selecting outcome measures for use in clinical and research practice recommend that properties such as validity and reliability are considered. This systematic review reports on the reliability and validity of non-invasive methods for measuring thoracic kyphosis. A systematic search of 11 electronic databases located studies assessing reliability and/or validity of non-invasive thoracic kyphosis measurement techniques. Two independent reviewers used a critical appraisal tool to assess the quality of retrieved studies. Data was extracted by the primary reviewer. The results were synthesized qualitatively using a level of evidence approach. 27 studies satisfied the eligibility criteria and were included in the review. The reliability, validity and both reliability and validity were investigated by sixteen, two and nine studies respectively. 17/27 studies were deemed to be of high quality. In total, 15 methods of thoracic kyphosis were evaluated in retrieved studies. All investigated methods showed high (ICC ≥ .7) to very high (ICC ≥ .9) levels of reliability. The validity of the methods ranged from low to very high. The strongest levels of evidence for reliability exists in support of the Debrunner kyphometer, Spinal Mouse and Flexicurve index, and for validity supports the arcometer and Flexicurve index. Further reliability and validity studies are required to strengthen the level of evidence for the remaining methods of measurement. This should be addressed by future research. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Reliability of pulse diagnosis in traditional Indian Ayurveda medicine

    DEFF Research Database (Denmark)

    Kurande, Vrinda Hitendra; Waagepetersen, Rasmus; Toft, Egon

    2013-01-01

    In Ayurveda, pulse diagnosis is an important diagnostic method to assess the status of three doshas (bio-entity: vata, pitta and kapha) in the patient. However, this is only justifiable if this method is reliable. The aim of this study is to test the intra-rater and inter-rater reliability of pulse...... diagnosed various combinations of three bio-entities vata, pitta and kapha based on the qualitative description of pulse pattern in Ayurveda. Cohen's weighted kappa statistic was used as a measure of reliability and hypothesis of homogeneous diagnosis (random rating) was tested. The level of weighted kappa...... statistics for each doctor was -0.18, 0.12, 0.31, -0.02, 0.48, 0.1, 0.26, 0.2, 0.34, 0.15, 0.56, 0.03, 0.36, 0.21, 0.4 respectively and the hypothesis of homogeneous diagnosis was only significant (p = 0.04) at the 5 % level for one doctor. The kappa values are in general bigger for the group...

  16. Method for assessing software reliability of the document management system using the RFID technology

    Directory of Open Access Journals (Sweden)

    Kiedrowicz Maciej

    2016-01-01

    Full Text Available The deliberations presented in this study refer to the method for assessing software reliability of the docu-ment management system, using the RFID technology. A method for determining the reliability structure of the dis-cussed software, understood as the index vector for assessing reliability of its components, was proposed. The model of the analyzed software is the control transfer graph, in which the probability of activating individual components during the system's operation results from the so-called operational profile, which characterizes the actual working environment. The reliability structure is established as a result of the solution of a specific mathematical software task. The knowledge of the reliability structure of the software makes it possible to properly plan the time and finan-cial expenses necessary to build the software, which would meet the reliability requirements. The application of the presented method is illustrated by the number example, corresponding to the software reality of the RFID document management system.

  17. Structural system reliability calculation using a probabilistic fault tree analysis method

    Science.gov (United States)

    Torng, T. Y.; Wu, Y.-T.; Millwater, H. R.

    1992-01-01

    The development of a new probabilistic fault tree analysis (PFTA) method for calculating structural system reliability is summarized. The proposed PFTA procedure includes: developing a fault tree to represent the complex structural system, constructing an approximation function for each bottom event, determining a dominant sampling sequence for all bottom events, and calculating the system reliability using an adaptive importance sampling method. PFTA is suitable for complicated structural problems that require computer-intensive computer calculations. A computer program has been developed to implement the PFTA.

  18. Contactless Diagnostics of Turbine Blade Vibration and Damage

    International Nuclear Information System (INIS)

    Prochazka, Pavel; Vanek, Frantisek

    2011-01-01

    The study deals with the contactless diagnostic method used for the identification of steam turbine blade strain, vibration and damage. The tip-timing method based on the evaluation of time differences of blade passages in different rotor revolutions has been modified and improved to provide more precise and reliable results. A new approach to the analysis of the amplitude and time differences of impulse signals generated by a blade passage has been applied. Amplitudes and frequencies of vibrations and static position of blades ascertained by the diagnostic process are used to establish the state of blade damage. A contactless diagnostic system VDS-UT based on magneto-resistive sensors was developed in the Institute of Thermomechanics Academy of Sciences of the Czech Republic. The system provides on-line monitoring of vibration amplitudes and frequencies of all blades and notification of possible blade damage. Evaluation of the axial and circumferential components of the deflections by measuring the amplitude of blade impulse signals results in an overall improvement of the method. Using magneto-resistive sensors, blade elongation and untwisting can be determined as well.

  19. Depression and suicidal behavior in adolescents: a multi-informant and multi-methods approach to diagnostic classification.

    Directory of Open Access Journals (Sweden)

    Andrew James Lewis

    2014-07-01

    Full Text Available Background: Informant discrepancies have been reported between parent and adolescent measures of depressive disorders and suicidality. We aimed to examine the concordance between adolescent and parent ratings of depressive disorder using both clinical interview and questionnaire measures and assess multi-informant and multi-method approaches to classification.Method: Within the context of assessment of eligibility for a randomized clinical trial, 50 parent–adolescent pairs (mean age of adolescents = 15.0 years were interviewed separately with a structured diagnostic interview for depression, the KID-SCID. Adolescent self-report and parent-report versions of the Strengths and Difficulties Questionnaire, the Short Mood and Feelings Questionnaire and the Depressive Experiences Questionnaire were also administered. We examined the diagnostic concordance rates of the parent vs. adolescent structured interview methods and the prediction of adolescent diagnosis via questionnaire methods.Results: Parent proxy reporting of adolescent depression and suicidal thoughts and behavior is not strongly concordant with adolescent report. Adolescent self-reported symptoms on depression scales provide a more accurate report of diagnosable adolescent depression than parent proxy reports of adolescent depressive symptoms. Adolescent self-report measures can be combined to improve the accuracy of classification. Parents tend to over report their adolescent’s depressive symptoms while under reporting their suicidal thoughts and behavior.Conclusion: Parent proxy report is clearly less reliable than the adolescent’s own report of their symptoms and subjective experiences, and could be considered inaccurate for research purposes. While parent report would still be sought clinically where an adolescent refuses to provide information, our findings suggest that parent reporting of adolescent suicidality should be interpreted with caution.

  20. A human reliability based usability evaluation method for safety-critical software

    International Nuclear Information System (INIS)

    Boring, R. L.; Tran, T. Q.; Gertman, D. I.; Ragsdale, A.

    2006-01-01

    Boring and Gertman (2005) introduced a novel method that augments heuristic usability evaluation methods with that of the human reliability analysis method of SPAR-H. By assigning probabilistic modifiers to individual heuristics, it is possible to arrive at the usability error probability (UEP). Although this UEP is not a literal probability of error, it nonetheless provides a quantitative basis to heuristic evaluation. This method allows one to seamlessly prioritize and identify usability issues (i.e., a higher UEP requires more immediate fixes). However, the original version of this method required the usability evaluator to assign priority weights to the final UEP, thus allowing the priority of a usability issue to differ among usability evaluators. The purpose of this paper is to explore an alternative approach to standardize the priority weighting of the UEP in an effort to improve the method's reliability. (authors)

  1. Diagnostic method for photovoltaic systems based on light I-V measurements

    DEFF Research Database (Denmark)

    Spataru, Sergiu; Sera, Dezso; Kerekes, Tamas

    2015-01-01

    , be it external, such as shading or soiling, or degradation or failure of the PV modules and balance-of-system components. This allows for performing preventive and/or reparative maintenance, thus minimizing further losses and costs. This article proposes a complete diagnostic method for detecting shading...... and analysis of the diagnostic parameters and logic was performed based on module level tests on standard crystalline silicon PV modules, and were optimized to detect even small partial shading and increase series-resistance losses. To demonstrate the practical application and operation of this method...

  2. Therapy evaluation and diagnostic accuracy in neuroendocrine tumours: assessment of radiological methods

    International Nuclear Information System (INIS)

    Elvin, A.

    1993-01-01

    The diagnostic accuracy of ultrasonically guided biopsy-gun biopsies was assessed in a group of 47 patients with suspected pancreatic carcinoma. A correct diagnosis was obtained in 44 of the 47 patients (94%). Biopsy-gun biopsy of the pancreas is considered a useful, reliable and non-traumatic method for the diagnosis of pancreatic malignancy. Twenty-five patients with known neuroendocrine tumour disease were biopsied with 1.2 mm and 0.9 mm biopsy-gun needles. The influence of treatment-related fibrosis was also evaluated. The overall diagnostic accuracy with the 0.9 mm needle was 69% as compared to 92% with the 1.2 mm needle. In order to assess the diagnostic accuracy rate for radiologists with different experience of biopsy procedures 175 cases of renal biopsy-gun biopsies were evaluated. No statistical significant difference was found between the different operators. The role of duplex Doppler ultrasound in monitoring interferon treatment-related changes in carcinoid metastases was evaluated. It present duplex Doppler ultrasound does not seem to play a role in the evaluation of tumour therapy in carcinoid patients. Therapy response evaluation was performed with MR imaging in a group of 17 patients with neuroendocrine liver metastases. A significant difference was found between patients responding to and patients with failure of treatment in terms of tumour T1, contrast enhancement and signal intensity ratio. This indicates that MR investigation may be used in therapy monitoring of patients with neuroendocrine metastases. The neuroendocrine-differentiated colonic carcinoma cell line (LCC-18) was transplanted to 29 mice to establish a tumour/animal model that would allow the monitoring of changes with MR imaging induced by interferon therapy and to evaluate whether the therapeutic response could be modulated by different interferon dosages. Interferon does not seem to have any prolonged anti-proliferative effect on the LCC-18 tumour cell line when transplanted to

  3. Diagnostic methods of thermal dusty plasma flows

    International Nuclear Information System (INIS)

    Nefedov, A.P.

    1995-01-01

    The presence in the high-temperature flows of condensed disperse phase (CDP) particles may lead either to an increase of the electron number density n e if the particles assume a positive charge or to its decrease if the charge is negative. The existence of CDP also may effect on optical parameters of the thermal dusty plasma flows, on heat and radiative transfer in the plasma. The entire range of states, from a Debye plasma to a highly nonideal system of charged particles, is realized in a thermal dusty plasma under standard conditions T=2000-3000 K, n e =10 8 - 10 14 cm -3 . The advanced probe and optical diagnostic instruments are needed to study the optical and electrophysical properties of thermal dusty plasma flows. The diagnostic techniques must give the data about such parameters of gas and dispersed phase as temperatures of gas and particles, number densities of electrons, atoms and ions of alkali metals, sizes, velocities and concentrations of CDP particles. It should be noted that number density of alkali metal atoms and gas temperature may be measured by the well known full absorption and generalized reversal methods. This paper describes the probe and optical techniques for diagnostic of dusty plasma flows developed in High Energy Density Research Center of Russian Academy of Sciences. The Forward Angle Scattering Transmissometer (FAST) allows measurement of the average size (Sauter diameter), mass number density, and refractive index of particles in the 0.5-15.0 gm size range. The basis of the method is a dependence of the measured extinction of radiation upon an angular acceptance aperture of the photo detector. The FAST instrument allows one to determine the mass density and the Sauter diameter of a polydispersion of particles without a priori specification of the particle size distribution model and exact data about the article refractive index

  4. Diagnostic methods of thermal dusty plasma flows

    International Nuclear Information System (INIS)

    Nefedov, A.P.

    1995-01-01

    The presence in the high-temperature flows of condensed disperse phase (CDP) particles may lead either to an increase of the electron number density n e if the particles assume a positive charge or to its decrease if the charge is negative. The existence of CDP also may effect on optical parameters of the thermal dusty plasma flows, on heat and radiative transfer in the plasma. The entire range of states, from a Debye plasma to a highly nonideal system of charged particles, is realized in a thermal dusty plasma under standard conditions T=2000-3000 K, n e =10 8 -10 14 cm -3 . The advanced probe and optical diagnostic instruments are needed to study the optical and electrophysical properties of thermal dusty plasma flows. The diagnostic techniques must give the data about such parameters of gas and dispersed phase as temperatures of gas and particles, number densities of electrons, atoms and ions of alkali metals, sizes, velocities and concentrations of CDP particles. It should be noted that number density of alkali metal atoms and gas temperature may be measured by the well known full absorption and generalized reversal methods. This paper describes the probe and optical techniques for diagnostic of dusty plasma flows developed in High Energy Density Research Center of Russian Academy of Sciences. The Forward Angle Scattering Transmissometer (FAST) allows measurement of the average size (Sauter diameter), mass number density, and refractive index of particles in the 0.5-15.0 μm size range. The basis of the method is a dependence of the measured extinction of radiation upon an angular acceptance aperture of the photo detector. The FAST instrument allows one to determine the mass density and the Sauter diameter of a polydispersion of particles without a priori specification of the particle size distribution model and exact data about the particle refractive index

  5. DIAGNOSTIC CHARACTERISTICS OF THE COMPUTER TESTS FORMED BY METHOD OF RESTORED FRAGMENTS

    Directory of Open Access Journals (Sweden)

    Oleksandr O. Petkov

    2013-03-01

    Full Text Available Definition of validity and reliability of tests which are formed by a method of restored fragments is considered in the article. The structure of the controlled theoretical material of limit field of knowledge, language expressions that describe the subject of control, and reliability of test, is analyzed. The technique of definition of the most important components of reliability of the considered tests is given: reliability of quantitative determination of coefficient of assimilation and technological reliability. Results of the lead pedagogical experiments have proved, that tests of the given class allow to make the control of mastering of a theoretical material over a level of reproduction in any field of knowledge with high reliability. It is shown, that validity tests with restored fragments basically caused by a degree of structurization and methodical study of a controllable material and can achieve beforehand set parameters, down to a level of absolute validity.

  6. An exact method for solving logical loops in reliability analysis

    International Nuclear Information System (INIS)

    Matsuoka, Takeshi

    2009-01-01

    This paper presents an exact method for solving logical loops in reliability analysis. The systems that include logical loops are usually described by simultaneous Boolean equations. First, present a basic rule of solving simultaneous Boolean equations. Next, show the analysis procedures for three-component system with external supports. Third, more detailed discussions are given for the establishment of logical loop relation. Finally, take up two typical structures which include more than one logical loop. Their analysis results and corresponding GO-FLOW charts are given. The proposed analytical method is applicable to loop structures that can be described by simultaneous Boolean equations, and it is very useful in evaluating the reliability of complex engineering systems.

  7. Structural reliability methods: Code development status

    Science.gov (United States)

    Millwater, Harry R.; Thacker, Ben H.; Wu, Y.-T.; Cruse, T. A.

    1991-05-01

    The Probabilistic Structures Analysis Method (PSAM) program integrates state of the art probabilistic algorithms with structural analysis methods in order to quantify the behavior of Space Shuttle Main Engine structures subject to uncertain loadings, boundary conditions, material parameters, and geometric conditions. An advanced, efficient probabilistic structural analysis software program, NESSUS (Numerical Evaluation of Stochastic Structures Under Stress) was developed as a deliverable. NESSUS contains a number of integrated software components to perform probabilistic analysis of complex structures. A nonlinear finite element module NESSUS/FEM is used to model the structure and obtain structural sensitivities. Some of the capabilities of NESSUS/FEM are shown. A Fast Probability Integration module NESSUS/FPI estimates the probability given the structural sensitivities. A driver module, PFEM, couples the FEM and FPI. NESSUS, version 5.0, addresses component reliability, resistance, and risk.

  8. Reliable and Valid Assessment of Point-of-care Ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt

    2015-01-01

    physicians' OSAUS scores with diagnostic accuracy. RESULTS: The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores......OBJECTIVE: To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. BACKGROUND: POC US is increasingly used by clinicians and is an essential part of the management of acute surgical...... conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. METHODS: Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different...

  9. AK-SYS: An adaptation of the AK-MCS method for system reliability

    International Nuclear Information System (INIS)

    Fauriat, W.; Gayton, N.

    2014-01-01

    A lot of research work has been proposed over the last two decades to evaluate the probability of failure of a structure involving a very time-consuming mechanical model. Surrogate model approaches based on Kriging, such as the Efficient Global Reliability Analysis (EGRA) or the Active learning and Kriging-based Monte-Carlo Simulation (AK-MCS) methods, are very efficient and each has advantages of its own. EGRA is well suited to evaluating small probabilities, as the surrogate can be used to classify any population. AK-MCS is built in relation to a given population and requires no optimization program for the active learning procedure to be performed. It is therefore easier to implement and more likely to spend computational effort on areas with a significant probability content. When assessing system reliability, analytical approaches and first-order approximation are widely used in the literature. However, in the present paper we rather focus on sampling techniques and, considering the recent adaptation of the EGRA method for systems, a strategy is presented to adapt the AK-MCS method for system reliability. The AK-SYS method, “Active learning and Kriging-based SYStem reliability method”, is presented. Its high efficiency and accuracy are illustrated via various examples

  10. Depression of home cage wheel running: a reliable and clinically relevant method to assess migraine pain in rats.

    Science.gov (United States)

    Kandasamy, Ram; Lee, Andrea T; Morgan, Michael M

    2017-12-01

    The development of new anti-migraine treatments is limited by the difficulty inassessing migraine pain in laboratory animals. Depression of activity is one of the few diagnostic criteria formigraine that can be mimicked in rats. The goal of the present study was to test the hypothesis thatdepression of home cage wheel running is a reliable and clinically relevant method to assess migraine painin rats. Adult female rats were implanted with a cannula to inject allyl isothiocyanate (AITC) onto the dura to induce migraine pain, as has been shown before. Rats recovered from implantation surgery for 8 days in cages containing a running wheel. Home cage wheel running was recorded 23 h a day. AITC and the migraine medication sumatriptan were administered in the hour prior to onset of the dark phase. Administration of AITC caused a concentration-dependent decrease in wheel running that lasted 3 h. The duration and magnitude of AITC-induced depression of wheel running was consistent following three repeated injections spaced 48 h apart. Administration of sumatriptan attenuated AITC-induced depressionof wheel running when a large dose (1 mg/kg) was administered immediately following AITC administration. Wheel running patterns did not change when sumatriptan was given to naïve rats. These data indicate that home cage wheel running is a sensitive, reliable, and clinically relevant method to assess migraine pain in the rat.

  11. Integrated Markov-neural reliability computation method: A case for multiple automated guided vehicle system

    International Nuclear Information System (INIS)

    Fazlollahtabar, Hamed; Saidi-Mehrabad, Mohammad; Balakrishnan, Jaydeep

    2015-01-01

    This paper proposes an integrated Markovian and back propagation neural network approaches to compute reliability of a system. While states of failure occurrences are significant elements for accurate reliability computation, Markovian based reliability assessment method is designed. Due to drawbacks shown by Markovian model for steady state reliability computations and neural network for initial training pattern, integration being called Markov-neural is developed and evaluated. To show efficiency of the proposed approach comparative analyses are performed. Also, for managerial implication purpose an application case for multiple automated guided vehicles (AGVs) in manufacturing networks is conducted. - Highlights: • Integrated Markovian and back propagation neural network approach to compute reliability. • Markovian based reliability assessment method. • Managerial implication is shown in an application case for multiple automated guided vehicles (AGVs) in manufacturing networks

  12. Application of contemporary imaging methods in diagnostics of mild cognitive impairment

    International Nuclear Information System (INIS)

    Walecki, J.; Pawlowska-Detko, A.; Ignaciuk, K.; Gabryelewicz, T.; Barcikowska, M.

    2006-01-01

    Mild cognitive impairment (MCI) is defined as a heterogeneous clinical syndrome associated with high risk of the development of dementia, especially Alzheimer disease (AD). Owing to the recent advances in understanding of the molecular phenomena underlying AD there is a chance of introducing effective therapy for this disease in the near future. Therefore, improvement of early diagnostics methods and finding the markers of AD progression, especially in the high risk population of patients with MCI becomes a crucial issue. From the clinical point of view, great expectations are associated with neuroradiologic methods, which are hoped to make it possible to find the markers of conversion from MCI to dementia and the markers of dementia progression in subjects at risk of the development of AD. Growing interest in the problem of MCI diagnostics, reflected in numerous medical publications that have appeared during the recent few years, has prompted the authors to review and summarize the current knowledge concerning the application of modern neuroradiologic methods in the diagnostics of subjects with MCI. (author)

  13. Using the method of judgement analysis to address variations in diagnostic decision making

    OpenAIRE

    Hancock, Helen C; Mason, James M; Murphy, Jerry J

    2012-01-01

    Abstract Background Heart failure is not a clear-cut diagnosis but a complex clinical syndrome with consequent diagnostic uncertainty. Judgment analysis is a method to help clinical teams to understand how they make complex decisions. The method of judgment analysis was used to determine the factors that influence clinicians' diagnostic decisions about heart failure. Methods Three consultants, three middle grade doctors, and two junior doctors each evaluated 45 patient scenarios. The main out...

  14. Diagnostic examination of the urethra in the female and double-balloon urethrography as a diagnostic method

    International Nuclear Information System (INIS)

    Madeja, C.; Mutze, S.; Poetzschke, B.; Tunn, R.; Heinrich, G.; Hamm, B.

    1997-01-01

    The double-balloon urethrography can be recommended as an efficient diagnostic method for examination of the urethra in the female patient. Because of its improved controllability, retrograde application of the contrast agent is superior to other techniques. Complications can be avoided by maintaining constant pressure during contrast agent application. The few commercially available double-balloon instruments suffer from a number of deficiencies which are the reason for this technique having met with low acceptance, thus being only rarely applied. In addition, application of the instrument is not easy. Nevertheless, this diagnostic technique would deserve much more frequent application. (orig.) [de

  15. Reliability Analysis Of Fire System On The Industry Facility By Use Fameca Method

    International Nuclear Information System (INIS)

    Sony T, D.T.; Situmorang, Johnny; Ismu W, Puradwi; Demon H; Mulyanto, Dwijo; Kusmono, Slamet; Santa, Sigit Asmara

    2000-01-01

    FAMECA is one of the analysis method to determine system reliability on the industry facility. Analysis is done by some procedure that is identification of component function, determination of failure mode, severity level and effect of their failure. Reliability value is determined by three combinations that is severity level, component failure value and critical component. Reliability of analysis has been done for fire system on the industry by FAMECA method. Critical component which identified is pump, air release valve, check valve, manual test valve, isolation valve, control system etc

  16. Ultrasound evaluation of the abductor hallucis muscle: Reliability study

    Directory of Open Access Journals (Sweden)

    Hing Wayne A

    2008-09-01

    Full Text Available Abstract Background The Abductor hallucis muscle (AbdH plays an integral role during gait and is often affected in pathological foot conditions. The aim of this study was to evaluate the within and between-session intra-tester reliability using diagnostic ultrasound of the dorso-plantar thickness, medio-lateral width and cross-sectional area, of the AbdH in asymptomatic adults. Methods The AbdH muscles of thirty asymptomatic subjects were imaged and then measured using a Philips HD11 Ultrasound machine. Interclass correlation coefficients (ICC with 95% confidence intervals (CI were used to calculate both within and between session intra-tester reliability. Results The within-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.99–0.99; medio-lateral width an ICC: of 0.97 (95% CI: 0.92–0.97 and cross-sectional area an ICC of 0.98 (95% CI: 0.98–0.99. Between-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.95 to 0.98; medio-lateral width an ICC of 0.94 (95% CI 0.90 to 0.96 and for cross-sectional area an ICC of 0.79 (95% CI 0.65 to 0.88. Conclusion Diagnostic ultrasound has the potential to be a reliable tool for evaluating the AbdH muscle in asymptomatic subjects. Subsequent studies may be conducted to provide a better understanding of the AbdH function in foot and ankle pathologies.

  17. A Study on the Reliability of Sasang Constitutional Body Trunk Measurement

    Directory of Open Access Journals (Sweden)

    Eunsu Jang

    2012-01-01

    Full Text Available Objective. Body trunk measurement for human plays an important diagnostic role not only in conventional medicine but also in Sasang constitutional medicine (SCM. The Sasang constitutional body trunk measurement (SCBTM consists of the 5-widths and the 8-circumferences which are standard locations currently employed in the SCM society. This study suggests to what extent a comprehensive training can improve the reliability of the SCBTM. Methods. We recruited 10 male subjects and 5 male observers with no experience of anthropometric measurement. We conducted measurements twice before and after a comprehensive training. Relative technical error of measurement (%TEMs was produced to assess intra and inter observer reliabilities. Results. Post-training intra-observer %TEMs of the SCBTM were 0.27% to 1.85% reduced from 0.27% to 6.26% in pre-training, respectively. Post-training inter-observer %TEMs of those were 0.56% to 1.66% reduced from 1.00% to 9.60% in pre-training, respectively. Post-training % total TEMs which represent the whole reliability were 0.68% to 2.18% reduced from maximum value of 10.18%. Conclusion. A comprehensive training makes the SCBTM more reliable, hence giving a sufficiently confident diagnostic tool. It is strongly recommended to give a comprehensive training in advance to take the SCBTM.

  18. A study on the reliability of sasang constitutional body trunk measurement.

    Science.gov (United States)

    Jang, Eunsu; Kim, Jong Yeol; Lee, Haejung; Kim, Honggie; Baek, Younghwa; Lee, Siwoo

    2012-01-01

    Objective. Body trunk measurement for human plays an important diagnostic role not only in conventional medicine but also in Sasang constitutional medicine (SCM). The Sasang constitutional body trunk measurement (SCBTM) consists of the 5-widths and the 8-circumferences which are standard locations currently employed in the SCM society. This study suggests to what extent a comprehensive training can improve the reliability of the SCBTM. Methods. We recruited 10 male subjects and 5 male observers with no experience of anthropometric measurement. We conducted measurements twice before and after a comprehensive training. Relative technical error of measurement (%TEMs) was produced to assess intra and inter observer reliabilities. Results. Post-training intra-observer %TEMs of the SCBTM were 0.27% to 1.85% reduced from 0.27% to 6.26% in pre-training, respectively. Post-training inter-observer %TEMs of those were 0.56% to 1.66% reduced from 1.00% to 9.60% in pre-training, respectively. Post-training % total TEMs which represent the whole reliability were 0.68% to 2.18% reduced from maximum value of 10.18%. Conclusion. A comprehensive training makes the SCBTM more reliable, hence giving a sufficiently confident diagnostic tool. It is strongly recommended to give a comprehensive training in advance to take the SCBTM.

  19. COMPOSITE METHOD OF RELIABILITY RESEARCH FOR HIERARCHICAL MULTILAYER ROUTING SYSTEMS

    Directory of Open Access Journals (Sweden)

    R. B. Tregubov

    2016-09-01

    Full Text Available The paper deals with the idea of a research method for hierarchical multilayer routing systems. The method represents a composition of methods of graph theories, reliability, probabilities, etc. These methods are applied to the solution of different private analysis and optimization tasks and are systemically connected and coordinated with each other through uniform set-theoretic representation of the object of research. The hierarchical multilayer routing systems are considered as infrastructure facilities (gas and oil pipelines, automobile and railway networks, systems of power supply and communication with distribution of material resources, energy or information with the use of hierarchically nested functions of routing. For descriptive reasons theoretical constructions are considered on the example of task solution of probability determination for up state of specific infocommunication system. The author showed the possibility of constructive combination of graph representation of structure of the object of research and a logic probable analysis method of its reliability indices through uniform set-theoretic representation of its elements and processes proceeding in them.

  20. Nova target diagnostics control system

    International Nuclear Information System (INIS)

    Severyn, J.R.

    1985-01-01

    During the past year the Nova target diagnostics control system was finished and put in service. The diagnostics loft constructed to the north of the target room provides the environmental conditions required to collect reliable target diagnostic data. These improvements include equipment cooling and isolation of the power source with strict control of instrumentation grounds to eliminate data corruption due to electromagnetic pulses from the laser power-conditioning system or from target implosion effects

  1. [Methods of mathematical modeling in morphological diagnostics of Chernobyl factor influence on the testes of coal miners of Donbas--the Chernobyl disaster fighters].

    Science.gov (United States)

    Danylov, Iu V; Motkov, K V; Shevchenko, T I

    2014-01-01

    The morphometric estimation of parenchyma and stroma condition included the determination of 29 parameters in testicles at 27 persons. The mathematical model of morphogenesis of testicles was created by Bayes' method. The method of differential diagnosis of testicles tissues' changes conditioned by the influence of the Chernobyl factor and/or unfavorable terms of the work in underground coal mines have been worked out. Its practical use provides exactness and reliability of the diagnosis (not less than 95%), independence from the level of the qualification and personal experience of the doctor, allows us to unify, optimize and individualize the diagnostic algorithms, answer the requirements of evidential medicine.

  2. Method of reduction of diagnostic parameters during observation on the example of a combustion engine

    Directory of Open Access Journals (Sweden)

    Orczyk Malgorzata

    2017-01-01

    Full Text Available The article presents a method of selecting diagnostic parameters which map the process of damaging the object. This method consists in calculating, during the observation, the correlation coefficient between the intensity of damage and the individual diagnostic parameters; and discarding of those parameters whose correlation coefficient values are outside of the narrowest confidence interval of the correlation coefficient. The characteristic feature of this method is that the parameters are reduced during the diagnostic experiment. The essence of the proposed method is illustrated by the vibration diagnosis of an internal combustion engine.

  3. Developing and testing a new method “Theme-situations” for the diagnostics of psychological readiness to developmental conflict resolution in youth

    Directory of Open Access Journals (Sweden)

    N.V. Gorlova

    2013-10-01

    Full Text Available We describe the procedure of development of the author's method for the study of psychological readiness to development conflict management in youth, consisting of three parts, which use the method of projection to varying degrees. The method involves diagnosis of development conflict management in adolescence and actualization of the basic contradictions of adolescence, associated with the importance of the following topics to a maturing individual: setting long-term goals, choice of professional self-realization, partner choice in a romantic relationship, solving the existential questions. The method involves identification of strategies to solve these conflicts by young people (asserting own position and “existential” type of answer to the existential question. It has been tested on the retest reliability and construct validity and showed a wide range of connections to the scales of many well-known psycho-diagnostic tools.

  4. A study in the reliability analysis method for nuclear power plant structures (I)

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Byung Hwan; Choi, Seong Cheol; Shin, Ho Sang; Yang, In Hwan; Kim, Yi Sung; Yu, Young; Kim, Se Hun [Seoul, Nationl Univ., Seoul (Korea, Republic of)

    1999-03-15

    Nuclear power plant structures may be exposed to aggressive environmental effects that may cause their strength and stiffness to decrease over their service life. Although the physics of these damage mechanisms are reasonably well understood and quantitative evaluation of their effects on time-dependent structural behavior is possible in some instances, such evaluations are generally very difficult and remain novel. The assessment of existing steel containment in nuclear power plants for continued service must provide quantitative evidence that they are able to withstand future extreme loads during a service period with an acceptable level of reliability. Rational methodologies to perform the reliability assessment can be developed from mechanistic models of structural deterioration, using time-dependent structural reliability analysis to take loading and strength uncertainties into account. The final goal of this study is to develop the analysis method for the reliability of containment structures. The cause and mechanism of corrosion is first clarified and the reliability assessment method has been established. By introducing the equivalent normal distribution, the procedure of reliability analysis which can determine the failure probabilities has been established. The influence of design variables to reliability and the relation between the reliability and service life will be continued second year research.

  5. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    Science.gov (United States)

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  6. Reliability of clinical ICD-10 schizophrenia diagnoses

    DEFF Research Database (Denmark)

    Jakobsen, Klaus D; Frederiksen, Julie N; Hansen, Thomas

    2005-01-01

    Concern has been expressed as to the reliability of clinical ICD-10 diagnosis of schizophrenia. This study was designed to assess the diagnostic reliability of the clinical ICD-10 diagnosis of schizophrenia in a random sample of Danish in- and outpatients with a history of psychosis. A sample...... value (87%) of ICD-10 schizophrenia and an overall good agreement between clinical and OPCRIT-derived diagnoses (kappa=0.60). An even higher positive predictive value was obtained when diagnoses were amalgamated into a diagnostic entity of schizophrenia-spectrum disorders (98%). Near perfect agreement...... was seen between OPCRIT-derived ICD-10 and DSM-IV diagnoses (kappa=0.87). Thus, this study demonstrates high reliability of the clinical diagnosis of schizophrenia and even more so of the diagnosis of schizophrenia-spectrum disorder....

  7. A comparative study on the HW reliability assessment methods for digital I and C equipment

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hoan Sung; Sung, T. Y.; Eom, H. S.; Park, J. K.; Kang, H. G.; Lee, G. Y. [Korea Atomic Energy Research Institute, Taejeon (Korea); Kim, M. C. [Korea Advanced Institute of Science and Technology, Taejeon (Korea); Jun, S. T. [KHNP, Taejeon (Korea)

    2002-03-01

    It is necessary to predict or to evaluate the reliability of electronic equipment for the probabilistic safety analysis of digital instrument and control equipment. But most databases for the reliability prediction have no data for the up-to-date equipment and the failure modes are not classified. The prediction results for the specific component show different values according to the methods and databases. For boards and systems each method shows different values than others also. This study is for reliability prediction of PDC system for Wolsong NPP1 as a digital I and C equipment. Various reliability prediction methods and failure databases are used in calculation of the reliability to compare the effects of sensitivity and accuracy of each model and database. Many considerations for the reliability assessment of digital systems are derived with the results of this study. 14 refs., 19 figs., 15 tabs. (Author)

  8. Design of multitasking and windows software for beam diagnostic system on HIRFL

    International Nuclear Information System (INIS)

    Nie Zhenpeng; Shen Zhiqing; Xu Xiangyang; Zheng Jianping; Tang Jingyu; Dong Jinmei

    2002-01-01

    An introduction is given to the design idea and method of multitasking and Windows software for beam diagnostic system on HIRFL. The testing result is presented in the end. The software has many advantages such as powerful function, visual display, high reliability and friendly interface, etc

  9. DIAGNOSTIC CHARACTERISTICS OF THE COMPUTER TESTS FORMED BY METHOD OF RESTORED FRAGMENTS

    OpenAIRE

    Oleksandr O. Petkov

    2013-01-01

    Definition of validity and reliability of tests which are formed by a method of restored fragments is considered in the article. The structure of the controlled theoretical material of limit field of knowledge, language expressions that describe the subject of control, and reliability of test, is analyzed. The technique of definition of the most important components of reliability of the considered tests is given: reliability of quantitative determination of coefficient of assimilation and te...

  10. Cost analysis of breast cancer diagnostic assessment programs.

    Science.gov (United States)

    Honein-AbouHaidar, G N; Hoch, J S; Dobrow, M J; Stuart-McEwan, T; McCready, D R; Gagliardi, A R

    2017-10-01

    Diagnostic assessment programs (daps) appear to improve the diagnosis of cancer, but evidence of their cost-effectiveness is lacking. Given that no earlier study used secondary financial data to estimate the cost of diagnostic tests in the province of Ontario, we explored how to use secondary financial data to retrieve the cost of key diagnostic test services in daps, and we tested the reliability of that cost-retrieving method with hospital-reported costs in preparation for future cost-effectiveness studies. We powered our sample at an alpha of 0.05, a power of 80%, and a margin of error of ±5%, and randomly selected a sample of eligible patients referred to a dap for suspected breast cancer during 1 January-31 December 2012. Confirmatory diagnostic tests received by each patient were identified in medical records. Canadian Classification of Health Intervention procedure codes were used to search the secondary financial data Web portal at the Ontario Case Costing Initiative for an estimate of the direct, indirect, and total costs of each test. The hospital-reported cost of each test received was obtained from the host-hospital's finance department. Descriptive statistics were used to calculate the cost of individual or group confirmatory diagnostic tests, and the Wilcoxon signed-rank test or the paired t-test was used to compare the Ontario Case Costing Initiative and hospital-reported costs. For the 191 identified patients with suspected breast cancer, the estimated total cost of $72,195.50 was not significantly different from the hospital-reported total cost of $72,035.52 ( p = 0.24). Costs differed significantly when multiple tests to confirm the diagnosis were completed during one patient visit and when confirmatory tests reported in hospital data and in medical records were discrepant. The additional estimated cost for non-salaried physicians delivering diagnostic services was $28,387.50. It was feasible to use secondary financial data to retrieve the cost

  11. Cost-Effectiveness Analysis of Helicobacter pylori Diagnostic Methods in Patients with Atrophic Gastritis

    Directory of Open Access Journals (Sweden)

    Fumio Omata

    2017-01-01

    Full Text Available Background. There are several diagnostic methods for Helicobacter pylori (H. pylori infection. A cost-effective analysis is needed to decide on the optimal diagnostic method. The aim of this study was to determine a cost-effective diagnostic method in patients with atrophic gastritis (AG. Methods. A decision-analysis model including seven diagnostic methods was constructed for patients with AG diagnosed by esophagogastroduodenoscopy. Expected values of cost and effectiveness were calculated for each test. Results. If the prevalence of H. pylori in the patients with AG is 85% and CAM-resistant H. pylori is 30%, histology, stool H. pylori antigen (SHPAg, bacterial culture (BC, and urine H. pylori antibody (UHPAb were dominated by serum H. pylori IgG antibody (SHPAb, rapid urease test (RUT, and urea breath test (UBT. Among three undominated methods, the incremental cost-effective ratios (ICER of RUT versus SHPAb and UBT versus RUT were $214 and $1914, respectively. If the prevalence of CAM-sensitive H. pylori was less than 55%, BC was not dominated, but its H. pylori eradication success rate was 0.86. Conclusions. RUT was the most cost-effective at the current prevalence of CAM-resistant H. pylori. BC could not be selected due to its poor effectiveness even if CAM-resistant H. pylori was more than 45%.

  12. Model correction factor method for reliability problems involving integrals of non-Gaussian random fields

    DEFF Research Database (Denmark)

    Franchin, P.; Ditlevsen, Ove Dalager; Kiureghian, Armen Der

    2002-01-01

    The model correction factor method (MCFM) is used in conjunction with the first-order reliability method (FORM) to solve structural reliability problems involving integrals of non-Gaussian random fields. The approach replaces the limit-state function with an idealized one, in which the integrals ...

  13. High speed manyframe optical methods for plasma diagnostics

    International Nuclear Information System (INIS)

    Erokhin, A.A.; Shikanov, A.S.; Sklizkov, G.V.; Zakharenkov, Yu.A.; Zorev, N.N.

    1979-01-01

    A complex of active optical plasma and strong ionized shock wave diagnostics is described. The complex consisted of a specially developed high speed manyframe systems of shadow, schlieren and interferometric photography. The comparison of results obtained by a simultaneous registration of investigated object by means of different optical methods allowed us to determine optimal employment range for the methods. The sensitivity, temporal and space resolution of each optical method under conditions of high probe radiation refraction are discussed. The application boundaries of these methods for ionized shock wave investigation were found to depend on the shock wave front width. The methods described were used for the study of laser-produced plasma phenomena, occuring in the experiments on powerful nine-channel laser installation ''Kalmar''. (author)

  14. A dynamic discretization method for reliability inference in Dynamic Bayesian Networks

    International Nuclear Information System (INIS)

    Zhu, Jiandao; Collette, Matthew

    2015-01-01

    The material and modeling parameters that drive structural reliability analysis for marine structures are subject to a significant uncertainty. This is especially true when time-dependent degradation mechanisms such as structural fatigue cracking are considered. Through inspection and monitoring, information such as crack location and size can be obtained to improve these parameters and the corresponding reliability estimates. Dynamic Bayesian Networks (DBNs) are a powerful and flexible tool to model dynamic system behavior and update reliability and uncertainty analysis with life cycle data for problems such as fatigue cracking. However, a central challenge in using DBNs is the need to discretize certain types of continuous random variables to perform network inference while still accurately tracking low-probability failure events. Most existing discretization methods focus on getting the overall shape of the distribution correct, with less emphasis on the tail region. Therefore, a novel scheme is presented specifically to estimate the likelihood of low-probability failure events. The scheme is an iterative algorithm which dynamically partitions the discretization intervals at each iteration. Through applications to two stochastic crack-growth example problems, the algorithm is shown to be robust and accurate. Comparisons are presented between the proposed approach and existing methods for the discretization problem. - Highlights: • A dynamic discretization method is developed for low-probability events in DBNs. • The method is compared to existing approaches on two crack growth problems. • The method is shown to improve on existing methods for low-probability events

  15. Dental and dental hygiene students' diagnostic accuracy in oral radiology: effect of diagnostic strategy and instructional method.

    Science.gov (United States)

    Baghdady, Mariam T; Carnahan, Heather; Lam, Ernest W N; Woods, Nicole N

    2014-09-01

    There has been much debate surrounding diagnostic strategies and the most appropriate training models for novices in oral radiology. It has been argued that an analytic approach, using a step-by-step analysis of the radiographic features of an abnormality, is ideal. Alternative research suggests that novices can successfully employ non-analytic reasoning. Many of these studies do not take instructional methodology into account. This study evaluated the effectiveness of non-analytic and analytic strategies in radiographic interpretation and explored the relationship between instructional methodology and diagnostic strategy. Second-year dental and dental hygiene students were taught four radiographic abnormalities using basic science instructions or a step-by-step algorithm. The students were tested on diagnostic accuracy and memory immediately after learning and one week later. A total of seventy-three students completed both immediate and delayed sessions and were included in the analysis. Students were randomly divided into two instructional conditions: one group provided a diagnostic hypothesis for the image and then identified specific features to support it, while the other group first identified features and then provided a diagnosis. Participants in the diagnosis-first condition (non-analytic reasoning) had higher diagnostic accuracy then those in the features-first condition (analytic reasoning), regardless of their learning condition. No main effect of learning condition or interaction with diagnostic strategy was observed. Educators should be mindful of the potential influence of analytic and non-analytic approaches on the effectiveness of the instructional method.

  16. Modern methods of early diagnostics of juvenile arthritis

    Directory of Open Access Journals (Sweden)

    Chernenkov Y.V.

    2013-06-01

    Full Text Available The problem of inflammatory diseases of joints is one of the most important issues in the pediatrics. Nowadays the significant attention in this sphere is paid to the search of new accurate criteria of diagnostics. It will help estimate the severity of disease, determine the prognosis, choose the method of treatment and monitoring and evaluate the efficacy of the therapy.

  17. Diagnostic efficacy of in vitro methods vs. skin testing in patients with inhalant allergies

    International Nuclear Information System (INIS)

    Corey, J.P.; Liudahl, J.J.; Young, S.A.; Rodman, S.M.

    1991-01-01

    The purpose of our study was to investigate the diagnostic efficacy of two selected methods of in vitro allergy testing. Specifically, the PRIST/modified RAST I125 isotope systems and the Quantizyme/modified EAST alkaline phosphatase method were compared. The time, expense, convenience, and diagnostic efficacy of the two procedures are discussed. Special attention is given to the practicality of each method for the practicing physician

  18. Systematic reviews of diagnostic tests in endocrinology: an audit of methods, reporting, and performance.

    Science.gov (United States)

    Spencer-Bonilla, Gabriela; Singh Ospina, Naykky; Rodriguez-Gutierrez, Rene; Brito, Juan P; Iñiguez-Ariza, Nicole; Tamhane, Shrikant; Erwin, Patricia J; Murad, M Hassan; Montori, Victor M

    2017-07-01

    Systematic reviews provide clinicians and policymakers estimates of diagnostic test accuracy and their usefulness in clinical practice. We identified all available systematic reviews of diagnosis in endocrinology, summarized the diagnostic accuracy of the tests included, and assessed the credibility and clinical usefulness of the methods and reporting. We searched Ovid MEDLINE, EMBASE, and Cochrane CENTRAL from inception to December 2015 for systematic reviews and meta-analyses reporting accuracy measures of diagnostic tests in endocrinology. Experienced reviewers independently screened for eligible studies and collected data. We summarized the results, methods, and reporting of the reviews. We performed subgroup analyses to categorize diagnostic tests as most useful based on their accuracy. We identified 84 systematic reviews; half of the tests included were classified as helpful when positive, one-fourth as helpful when negative. Most authors adequately reported how studies were identified and selected and how their trustworthiness (risk of bias) was judged. Only one in three reviews, however, reported an overall judgment about trustworthiness and one in five reported using adequate meta-analytic methods. One in four reported contacting authors for further information and about half included only patients with diagnostic uncertainty. Up to half of the diagnostic endocrine tests in which the likelihood ratio was calculated or provided are likely to be helpful in practice when positive as are one-quarter when negative. Most diagnostic systematic reviews in endocrine lack methodological rigor, protection against bias, and offer limited credibility. Substantial efforts, therefore, seem necessary to improve the quality of diagnostic systematic reviews in endocrinology.

  19. Reliability and discriminatory power of methods for dental plaque quantification

    Directory of Open Access Journals (Sweden)

    Daniela Prócida Raggio

    2010-04-01

    Full Text Available OBJECTIVE: This in situ study evaluated the discriminatory power and reliability of methods of dental plaque quantification and the relationship between visual indices (VI and fluorescence camera (FC to detect plaque. MATERIAL AND METHODS: Six volunteers used palatal appliances with six bovine enamel blocks presenting different stages of plaque accumulation. The presence of plaque with and without disclosing was assessed using VI. Images were obtained with FC and digital camera in both conditions. The area covered by plaque was assessed. Examinations were done by two independent examiners. Data were analyzed by Kruskal-Wallis and Kappa tests to compare different conditions of samples and to assess the inter-examiner reproducibility. RESULTS: Some methods presented adequate reproducibility. The Turesky index and the assessment of area covered by disclosed plaque in the FC images presented the highest discriminatory powers. CONCLUSION: The Turesky index and images with FC with disclosing present good reliability and discriminatory power in quantifying dental plaque.

  20. Application of reliability analysis methods to the comparison of two safety circuits

    International Nuclear Information System (INIS)

    Signoret, J.-P.

    1975-01-01

    Two circuits of different design, intended for assuming the ''Low Pressure Safety Injection'' function in PWR reactors are analyzed using reliability methods. The reliability analysis of these circuits allows the failure trees to be established and the failure probability derived. The dependence of these results on test use and maintenance is emphasized as well as critical paths. The great number of results obtained may allow a well-informed choice taking account of the reliability wanted for the type of circuits [fr

  1. Improved Efficiency and Reliability of NGS Amplicon Sequencing Data Analysis for Genetic Diagnostic Procedures Using AGSA Software

    Directory of Open Access Journals (Sweden)

    Axel Poulet

    2016-01-01

    Full Text Available Screening for BRCA mutations in women with familial risk of breast or ovarian cancer is an ideal situation for high-throughput sequencing, providing large amounts of low cost data. However, 454, Roche, and Ion Torrent, Thermo Fisher, technologies produce homopolymer-associated indel errors, complicating their use in routine diagnostics. We developed software, named AGSA, which helps to detect false positive mutations in homopolymeric sequences. Seventy-two familial breast cancer cases were analysed in parallel by amplicon 454 pyrosequencing and Sanger dideoxy sequencing for genetic variations of the BRCA genes. All 565 variants detected by dideoxy sequencing were also detected by pyrosequencing. Furthermore, pyrosequencing detected 42 variants that were missed with Sanger technique. Six amplicons contained homopolymer tracts in the coding sequence that were systematically misread by the software supplied by Roche. Read data plotted as histograms by AGSA software aided the analysis considerably and allowed validation of the majority of homopolymers. As an optimisation, additional 250 patients were analysed using microfluidic amplification of regions of interest (Access Array Fluidigm of the BRCA genes, followed by 454 sequencing and AGSA analysis. AGSA complements a complete line of high-throughput diagnostic sequence analysis, reducing time and costs while increasing reliability, notably for homopolymer tracts.

  2. Reliability of Lyapunov characteristic exponents computed by the two-particle method

    Science.gov (United States)

    Mei, Lijie; Huang, Li

    2018-03-01

    For highly complex problems, such as the post-Newtonian formulation of compact binaries, the two-particle method may be a better, or even the only, choice to compute the Lyapunov characteristic exponent (LCE). This method avoids the complex calculations of variational equations compared with the variational method. However, the two-particle method sometimes provides spurious estimates to LCEs. In this paper, we first analyze the equivalence in the definition of LCE between the variational and two-particle methods for Hamiltonian systems. Then, we develop a criterion to determine the reliability of LCEs computed by the two-particle method by considering the magnitude of the initial tangent (or separation) vector ξ0 (or δ0), renormalization time interval τ, machine precision ε, and global truncation error ɛT. The reliable Lyapunov characteristic indicators estimated by the two-particle method form a V-shaped region, which is restricted by d0, ε, and ɛT. Finally, the numerical experiments with the Hénon-Heiles system, the spinning compact binaries, and the post-Newtonian circular restricted three-body problem strongly support the theoretical results.

  3. Dependent systems reliability estimation by structural reliability approach

    DEFF Research Database (Denmark)

    Kostandyan, Erik; Sørensen, John Dalsgaard

    2014-01-01

    Estimation of system reliability by classical system reliability methods generally assumes that the components are statistically independent, thus limiting its applicability in many practical situations. A method is proposed for estimation of the system reliability with dependent components, where...... the leading failure mechanism(s) is described by physics of failure model(s). The proposed method is based on structural reliability techniques and accounts for both statistical and failure effect correlations. It is assumed that failure of any component is due to increasing damage (fatigue phenomena...... identification. Application of the proposed method can be found in many real world systems....

  4. Effect of patient age awareness on diagnostic agreement of chronic or aggressive periodontitis between clinicians; a pilot study

    OpenAIRE

    Oshman, Sarah; El Chaar, Edgard; Lee, Yoonjung Nicole; Engebretson, Steven

    2016-01-01

    Background The aim of this pilot study was to test whether diagnostic agreement of aggressive and chronic periodontitis amongst Board Certified Periodontists, is influenced by knowledge of a patient?s age. In 1999 at the International World Workshop age was removed as a diagnostic criteria for aggressive periodontitis. The impact of this change on the diagnostic reliability amongst clinicians has not yet been assessed. Methods Nine periodontal case reports were twice presented to sixteen boar...

  5. Method of evaluation of diagnostics reference levels in computerized tomography

    International Nuclear Information System (INIS)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  6. Multi-method automated diagnostics of rotating machines

    Science.gov (United States)

    Kostyukov, A. V.; Boychenko, S. N.; Shchelkanov, A. V.; Burda, E. A.

    2017-08-01

    The automated machinery diagnostics and monitoring systems utilized within the petrochemical plants are an integral part of the measures taken to ensure safety and, as a consequence, the efficiency of these industrial facilities. Such systems are often limited in their functionality due to the specifics of the diagnostic techniques adopted. As the diagnostic techniques applied in each system are limited, and machinery defects can have different physical nature, it becomes necessary to combine several diagnostics and monitoring systems to control various machinery components. Such an approach is inconvenient, since it requires additional measures to bring the diagnostic results in a single view of the technical condition of production assets. In this case, we mean by a production facility a bonded complex of a process unit, a drive, a power source and lines. A failure of any of these components will cause an outage of the production asset, which is unacceptable. The purpose of the study is to test a combined use of vibration diagnostics and partial discharge techniques within the diagnostic systems of enterprises for automated control of the technical condition of rotating machinery during maintenance and at production facilities. The described solutions allow you to control the condition of mechanical and electrical components of rotating machines. It is shown that the functionality of the diagnostics systems can be expanded with minimal changes in technological chains of repair and operation of rotating machinery. Automation of such systems reduces the influence of the human factor on the quality of repair and diagnostics of the machinery.

  7. A fast approximation method for reliability analysis of cold-standby systems

    International Nuclear Information System (INIS)

    Wang, Chaonan; Xing, Liudong; Amari, Suprasad V.

    2012-01-01

    Analyzing reliability of large cold-standby systems has been a complicated and time-consuming task, especially for systems with components having non-exponential time-to-failure distributions. In this paper, an approximation model, which is based on the central limit theorem, is presented for the reliability analysis of binary cold-standby systems. The proposed model can estimate the reliability of large cold-standby systems with binary-state components having arbitrary time-to-failure distributions in an efficient and easy way. The accuracy and efficiency of the proposed method are illustrated using several different types of distributions for both 1-out-of-n and k-out-of-n cold-standby systems.

  8. A Novel Reliability Enhanced Handoff Method in Future Wireless Heterogeneous Networks

    Directory of Open Access Journals (Sweden)

    Wang YuPeng

    2016-01-01

    Full Text Available As the demand increases, future networks will follow the trends of network variety and service flexibility, which requires heterogeneous type of network deployment and reliable communication method. In practice, most communication failure happens due to the bad radio link quality, i.e., high-speed users suffers a lot on the problem of radio link failure, which causes the problem of communication interrupt and radio link recovery. To make the communication more reliable, especially for the high mobility users, we propose a novel communication handoff mechanism to reduce the occurrence of service interrupt. Based on computer simulation, we find that the reliability on the service is greatly improved.

  9. A Bayesian reliability evaluation method with integrated accelerated degradation testing and field information

    International Nuclear Information System (INIS)

    Wang, Lizhi; Pan, Rong; Li, Xiaoyang; Jiang, Tongmin

    2013-01-01

    Accelerated degradation testing (ADT) is a common approach in reliability prediction, especially for products with high reliability. However, oftentimes the laboratory condition of ADT is different from the field condition; thus, to predict field failure, one need to calibrate the prediction made by using ADT data. In this paper a Bayesian evaluation method is proposed to integrate the ADT data from laboratory with the failure data from field. Calibration factors are introduced to calibrate the difference between the lab and the field conditions so as to predict a product's actual field reliability more accurately. The information fusion and statistical inference procedure are carried out through a Bayesian approach and Markov chain Monte Carlo methods. The proposed method is demonstrated by two examples and the sensitivity analysis to prior distribution assumption

  10. Reliability analysis of reactor systems by applying probability method; Analiza pouzdanosti reaktorskih sistema primenom metoda verovatnoce

    Energy Technology Data Exchange (ETDEWEB)

    Milivojevic, S [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1974-12-15

    Probability method was chosen for analysing the reactor system reliability is considered realistic since it is based on verified experimental data. In fact this is a statistical method. The probability method developed takes into account the probability distribution of permitted levels of relevant parameters and their particular influence on the reliability of the system as a whole. The proposed method is rather general, and was used for problem of thermal safety analysis of reactor system. This analysis enables to analyze basic properties of the system under different operation conditions, expressed in form of probability they show the reliability of the system on the whole as well as reliability of each component.

  11. Calculation of the reliability of large complex systems by the relevant path method

    International Nuclear Information System (INIS)

    Richter, G.

    1975-03-01

    In this paper, analytical methods are presented and tested with which the probabilistic reliability data of technical systems can be determined for given fault trees and block diagrams and known reliability data of the components. (orig./AK) [de

  12. Review of Reliability-Based Design Optimization Approach and Its Integration with Bayesian Method

    Science.gov (United States)

    Zhang, Xiangnan

    2018-03-01

    A lot of uncertain factors lie in practical engineering, such as external load environment, material property, geometrical shape, initial condition, boundary condition, etc. Reliability method measures the structural safety condition and determine the optimal design parameter combination based on the probabilistic theory. Reliability-based design optimization (RBDO) is the most commonly used approach to minimize the structural cost or other performance under uncertainty variables which combines the reliability theory and optimization. However, it cannot handle the various incomplete information. The Bayesian approach is utilized to incorporate this kind of incomplete information in its uncertainty quantification. In this paper, the RBDO approach and its integration with Bayesian method are introduced.

  13. A Hybrid Neural Network-Genetic Algorithm Technique for Aircraft Engine Performance Diagnostics

    Science.gov (United States)

    Kobayashi, Takahisa; Simon, Donald L.

    2001-01-01

    In this paper, a model-based diagnostic method, which utilizes Neural Networks and Genetic Algorithms, is investigated. Neural networks are applied to estimate the engine internal health, and Genetic Algorithms are applied for sensor bias detection and estimation. This hybrid approach takes advantage of the nonlinear estimation capability provided by neural networks while improving the robustness to measurement uncertainty through the application of Genetic Algorithms. The hybrid diagnostic technique also has the ability to rank multiple potential solutions for a given set of anomalous sensor measurements in order to reduce false alarms and missed detections. The performance of the hybrid diagnostic technique is evaluated through some case studies derived from a turbofan engine simulation. The results show this approach is promising for reliable diagnostics of aircraft engines.

  14. A reliable method for the stability analysis of structures ...

    African Journals Online (AJOL)

    The detection of structural configurations with singular tangent stiffness matrix is essential because they can be unstable. The secondary paths, especially in unstable buckling, can play the most important role in the loss of stability and collapse of the structure. A new method for reliable detection and accurate computation of ...

  15. A web-based test of residents' skills in diagnostic radiology

    International Nuclear Information System (INIS)

    Finlay, K.; Norman, G.R.; Keane, D.R.; Stolberg, H.

    2006-01-01

    To develop an objective, Web-based tool for evaluating residents' knowledge of diagnostic radiology. We developed and tested a Web-based evaluation tool (the Diagnostic Radiology Skills Test) that consists of 3 tests, one in each of 3 domains of diagnostic radiology: chest, gastrointestinal, and musculoskeletal imaging. Each test comprises 30 cases representing a range of difficulty in the domain, including normal states, normal variants, typical cases of common diagnoses, and cases with more subtle findings. Cases are presented with a long menu of domain-specific possible diagnoses (response options), each coded for diagnostic appropriateness. Our subjects were 21 residents in postgraduate year (PGY) 2 to 5 and 11 experts in diagnostic radiology. Subjects accessed the tool via a Web site on our Web server. Residents test results were compared for reliability and validity across domain, case, and training level. In addition, results were correlated with commonly used established and objective evaluation tools. The tool demonstrated consistent monotonic improvement in performance with training level. It showed acceptable reliability in discriminating between residents at different performance levels, both within and across training levels (r = 0.53 within level and 0.69 across levels). Test results also had concurrent validity against the American College of Radiology In-Training Examination, a widely accepted objective assessment tool (r = 0.65, P < 0.01), and 2 Objective Structured Clinical Examinations (OSCEs) focusing on diagnostic skills (r = 0.78 and r 0.69, P < 0.01, respectively). Our study demonstrates the feasibility of a Web-based, standardized, objective assessment method for evaluating residents' performance. (author)

  16. A quantitative calculation for software reliability evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young-Jun; Lee, Jang-Soo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    To meet these regulatory requirements, the software used in the nuclear safety field has been ensured through the development, validation, safety analysis, and quality assurance activities throughout the entire process life cycle from the planning phase to the installation phase. A variety of activities, such as the quality assurance activities are also required to improve the quality of a software. However, there are limitations to ensure that the quality is improved enough. Therefore, the effort to calculate the reliability of the software continues for a quantitative evaluation instead of a qualitative evaluation. In this paper, we propose a quantitative calculation method for the software to be used for a specific operation of the digital controller in an NPP. After injecting random faults in the internal space of a developed controller and calculating the ability to detect the injected faults using diagnostic software, we can evaluate the software reliability of a digital controller in an NPP. We tried to calculate the software reliability of the controller in an NPP using a new method that differs from a traditional method. It calculates the fault detection coverage after injecting the faults into the software memory space rather than the activity through the life cycle process. We attempt differentiation by creating a new definition of the fault, imitating the software fault using the hardware, and giving a consideration and weights for injection faults.

  17. Reliability analysis based on a novel density estimation method for structures with correlations

    Directory of Open Access Journals (Sweden)

    Baoyu LI

    2017-06-01

    Full Text Available Estimating the Probability Density Function (PDF of the performance function is a direct way for structural reliability analysis, and the failure probability can be easily obtained by integration in the failure domain. However, efficiently estimating the PDF is still an urgent problem to be solved. The existing fractional moment based maximum entropy has provided a very advanced method for the PDF estimation, whereas the main shortcoming is that it limits the application of the reliability analysis method only to structures with independent inputs. While in fact, structures with correlated inputs always exist in engineering, thus this paper improves the maximum entropy method, and applies the Unscented Transformation (UT technique to compute the fractional moments of the performance function for structures with correlations, which is a very efficient moment estimation method for models with any inputs. The proposed method can precisely estimate the probability distributions of performance functions for structures with correlations. Besides, the number of function evaluations of the proposed method in reliability analysis, which is determined by UT, is really small. Several examples are employed to illustrate the accuracy and advantages of the proposed method.

  18. An overview of reliability methods in mechanical and structural design

    Science.gov (United States)

    Wirsching, P. H.; Ortiz, K.; Lee, S. J.

    1987-01-01

    An evaluation is made of modern methods of fast probability integration and Monte Carlo treatment for the assessment of structural systems' and components' reliability. Fast probability integration methods are noted to be more efficient than Monte Carlo ones. This is judged to be an important consideration when several point probability estimates must be made in order to construct a distribution function. An example illustrating the relative efficiency of the various methods is included.

  19. Interrater reliability of schizoaffective disorder compared with schizophrenia, bipolar disorder, and unipolar depression - A systematic review and meta-analysis.

    Science.gov (United States)

    Santelmann, Hanno; Franklin, Jeremy; Bußhoff, Jana; Baethge, Christopher

    2016-10-01

    Schizoaffective disorder is a common diagnosis in clinical practice but its nosological status has been subject to debate ever since it was conceptualized. Although it is key that diagnostic reliability is sufficient, schizoaffective disorder has been reported to have low interrater reliability. Evidence based on systematic review and meta-analysis methods, however, is lacking. Using a highly sensitive literature search in Medline, Embase, and PsycInfo we identified studies measuring the interrater reliability of schizoaffective disorder in comparison to schizophrenia, bipolar disorder, and unipolar disorder. Out of 4126 records screened we included 25 studies reporting on 7912 patients diagnosed by different raters. The interrater reliability of schizoaffective disorder was moderate (meta-analytic estimate of Cohen's kappa 0.57 [95% CI: 0.41-0.73]), and substantially lower than that of its main differential diagnoses (difference in kappa between 0.22 and 0.19). Although there was considerable heterogeneity, analyses revealed that the interrater reliability of schizoaffective disorder was consistently lower in the overwhelming majority of studies. The results remained robust in subgroup and sensitivity analyses (e.g., diagnostic manual used) as well as in meta-regressions (e.g., publication year) and analyses of publication bias. Clinically, the results highlight the particular importance of diagnostic re-evaluation in patients diagnosed with schizoaffective disorder. They also quantify a widely held clinical impression of lower interrater reliability and agree with earlier meta-analysis reporting low test-retest reliability. Copyright © 2016. Published by Elsevier B.V.

  20. Reliability and Validity of the Footprint Assessment Method Using Photoshop CS5 Software.

    Science.gov (United States)

    Gutiérrez-Vilahú, Lourdes; Massó-Ortigosa, Núria; Costa-Tutusaus, Lluís; Guerra-Balic, Myriam

    2015-05-01

    Several sophisticated methods of footprint analysis currently exist. However, it is sometimes useful to apply standard measurement methods of recognized evidence with an easy and quick application. We sought to assess the reliability and validity of a new method of footprint assessment in a healthy population using Photoshop CS5 software (Adobe Systems Inc, San Jose, California). Forty-two footprints, corresponding to 21 healthy individuals (11 men with a mean ± SD age of 20.45 ± 2.16 years and 10 women with a mean ± SD age of 20.00 ± 1.70 years) were analyzed. Footprints were recorded in static bipedal standing position using optical podography and digital photography. Three trials for each participant were performed. The Hernández-Corvo, Chippaux-Smirak, and Staheli indices and the Clarke angle were calculated by manual method and by computerized method using Photoshop CS5 software. Test-retest was used to determine reliability. Validity was obtained by intraclass correlation coefficient (ICC). The reliability test for all of the indices showed high values (ICC, 0.98-0.99). Moreover, the validity test clearly showed no difference between techniques (ICC, 0.99-1). The reliability and validity of a method to measure, assess, and record the podometric indices using Photoshop CS5 software has been demonstrated. This provides a quick and accurate tool useful for the digital recording of morphostatic foot study parameters and their control.

  1. PARAMETRIC DIAGNOSTICS OF THE CENTRIFUGAL SUPERCHARGER'S TECHNICAL CONDITION DURING OPERATION

    Directory of Open Access Journals (Sweden)

    Regina A. Khuramshina

    2017-01-01

    Full Text Available Abstract. Objectives The main aim is to develop a mathematical model of a centrifugal compressor and carry out a parametric diagnostics of a centrifugal supercharger's technical condition during operation. Methods  A model is proposed for calculating the thermodynamic properties of natural gas, reducing the parameters of a centrifugal compressor to the initial conditions and to the rotation frequency, as well as the integral indicators of the supercharger's technical state. The technical state of the gas path of the centrifugal supercharger of the compressor unit is determined by the parametric diagnostic method. Results  The software implementation of the mathematical model of centrifugal compressor is carried out using a DVIGwT PC. The analysis of calculations indicates that the model is appropriate, with the error being due to taking into account the properties of iso-butane and i-hexane, in contrast with the VNIIGAZ technique. The evaluation studies of a centrifugal compressor's state are indicative of the presence or absence of its defects. Conclusion  Among a number of the diagnostic methods for evaluating a centrifugal supercharger, the most effective is vibrodiagnostics. However, the search for malfunctions and nascent defects in the flowing part of the centrifugal compressor cannot be limited only to vibrodiagnostic data, which provides about 60% of the reliable information about the state of the gas-air tract. About 20% of the compressor's malfunctions and approximately half of the dangerous modes of the supercharger's flow-through part is detected using thermogasdynamic parametric analysis (parametric diagnostics. The main difficulty of the control over the technical state of the flow-through part of the centrifugal supercharger is in the complication of the quantitative evaluation of the processes taking place in the supercharger, which leads to problems in providing reliable diagnosis during a reasonable period of time.

  2. Network reliability analysis of complex systems using a non-simulation-based method

    International Nuclear Information System (INIS)

    Kim, Youngsuk; Kang, Won-Hee

    2013-01-01

    Civil infrastructures such as transportation, water supply, sewers, telecommunications, and electrical and gas networks often establish highly complex networks, due to their multiple source and distribution nodes, complex topology, and functional interdependence between network components. To understand the reliability of such complex network system under catastrophic events such as earthquakes and to provide proper emergency management actions under such situation, efficient and accurate reliability analysis methods are necessary. In this paper, a non-simulation-based network reliability analysis method is developed based on the Recursive Decomposition Algorithm (RDA) for risk assessment of generic networks whose operation is defined by the connections of multiple initial and terminal node pairs. The proposed method has two separate decomposition processes for two logical functions, intersection and union, and combinations of these processes are used for the decomposition of any general system event with multiple node pairs. The proposed method is illustrated through numerical network examples with a variety of system definitions, and is applied to a benchmark gas transmission pipe network in Memphis TN to estimate the seismic performance and functional degradation of the network under a set of earthquake scenarios.

  3. A generic method for assignment of reliability scores applied to solvent accessibility predictions

    DEFF Research Database (Denmark)

    Petersen, Bent; Petersen, Thomas Nordahl; Andersen, Pernille

    2009-01-01

    : The performance of the neural networks was evaluated on a commonly used set of sequences known as the CB513 set. An overall Pearson's correlation coefficient of 0.72 was obtained, which is comparable to the performance of the currently best public available method, Real-SPINE. Both methods associate a reliability...... comparing the Pearson's correlation coefficient for the upper 20% of predictions sorted according to reliability. For this subset, values of 0.79 and 0.74 are obtained using our and the compared method, respectively. This tendency is true for any selected subset....

  4. Study on reliability analysis based on multilevel flow models and fault tree method

    International Nuclear Information System (INIS)

    Chen Qiang; Yang Ming

    2014-01-01

    Multilevel flow models (MFM) and fault tree method describe the system knowledge in different forms, so the two methods express an equivalent logic of the system reliability under the same boundary conditions and assumptions. Based on this and combined with the characteristics of MFM, a method mapping MFM to fault tree was put forward, thus providing a way to establish fault tree rapidly and realizing qualitative reliability analysis based on MFM. Taking the safety injection system of pressurized water reactor nuclear power plant as an example, its MFM was established and its reliability was analyzed qualitatively. The analysis result shows that the logic of mapping MFM to fault tree is correct. The MFM is easily understood, created and modified. Compared with the traditional fault tree analysis, the workload is greatly reduced and the modeling time is saved. (authors)

  5. Reliability analysis of minimum energy on target for laser facilities with more beam lines

    International Nuclear Information System (INIS)

    Chen Guangyu

    2008-01-01

    Shot reliability performance measures of laser facilities with more beam lines pertain to three categories: minimum-energy-on-target, power balance, and shot diagnostics. Accounting for symmetry of NIF beam line design and similarity of subset reliability in a same partition, a fault tree of meeting minimum-energy-on-target for the large laser facility shot of type K and a simplified method are presented, which are used to analyze hypothetic reliability of partition subsets in order to get trends of influences increasing number of beam lines and diverse shot types of large laser facilities on their shot reliability. Finally, it finds that improving component reliability is more crucial for laser facilities with more beam lines in comparison with those with beam lines and functional diversity from design flexibility is greatly helpful for improving shot reliability. (authors)

  6. Place of modern imaging methods and their influence on the diagnostic process

    International Nuclear Information System (INIS)

    Petkov, D.; Lazarova, I.

    1991-01-01

    The main trends in development of the modern imaging diagnostic methods are presented: increasing the specificity of CT, nuclear-magnetic resonance imaging, positron-emission tomography, digital substractional angiography, echography etc. based on modern technical improvements; objective representation of the physiological and biochemical divergencies in particular diseases; interventional radiology; integral application of different methods; improving the sensitivity and specificity of the methods based on developments in pharmacology (new contrast media, parmaceuticals influencing the function of examinated organs, etc.); the possibilities for data compilation and further computerized processing of primary data. Personal experience is reported with the exploitation of these methods in Bulgaria. Attention is also called to the unfavourable impact connected with the too strong technicization of the diagnostic and therapeutic process in a health, deontologic, economical and social respect. 15 refs

  7. Diagnostic methods of tubal factor in infertility

    International Nuclear Information System (INIS)

    Korzon, T.; Mielnik, J.; Gosciniak, W.

    1993-01-01

    The diagnostic methods of tubal factor in infertility have been presented. In details have been discussed PJ, PK HSG and pelviscopy. These examinations themselves constitute the basic ones in infertility. We turned our attention into technical details and possible mistakes which may occur at the time of performing them, these misinterpretations may lead to absolutely wrong conclusion and diagnosis. Authors have wide experience in performing the discussed examinations and this allows them to share their opinion. Over the years several thousand of PK and HSG examinations have been carried out and also 1000 laparoscopies. (author)

  8. Reliability model of SNS linac (spallation neutron source-ORNL)

    International Nuclear Information System (INIS)

    Pitigoi, A.; Fernandez, P.

    2015-01-01

    A reliability model of SNS LINAC (Spallation Neutron Source at Oak Ridge National Laboratory) has been developed using risk spectrum reliability analysis software and the analysis of the accelerator system's reliability has been performed. The analysis results have been evaluated by comparing them with the SNS operational data. This paper presents the main results and conclusions focusing on the definition of design weaknesses and provides recommendations to improve reliability of the MYRRHA ( linear accelerator. The reliability results show that the most affected SNS LINAC parts/systems are: 1) SCL (superconducting linac), front-end systems: IS, LEBT (low-energy beam transport line), MEBT (medium-energy beam transport line), diagnostics and controls; 2) RF systems (especially the SCL RF system); 3) power supplies and PS controllers. These results are in line with the records in the SNS logbook. The reliability issue that needs to be enforced in the linac design is the redundancy of the systems, subsystems and components most affected by failures. For compensation purposes, there is a need for intelligent fail-over redundancy implementation in controllers. Enough diagnostics has to be implemented to allow reliable functioning of the redundant solutions and to ensure the compensation function

  9. Test-retest reliability of schizoaffective disorder compared with schizophrenia, bipolar disorder, and unipolar depression--a systematic review and meta-analysis.

    Science.gov (United States)

    Santelmann, Hanno; Franklin, Jeremy; Bußhoff, Jana; Baethge, Christopher

    2015-11-01

    Schizoaffective disorder is a frequent diagnosis, and its reliability is subject to ongoing discussion. We compared the diagnostic reliability of schizoaffective disorder with its main differential diagnoses. We systematically searched Medline, Embase, and PsycInfo for all studies on the test-retest reliability of the diagnosis of schizoaffective disorder as compared with schizophrenia, bipolar disorder, and unipolar depression. We used meta-analytic methods to describe and compare Cohen's kappa as well as positive and negative agreement. In addition, multiple pre-specified and post hoc subgroup and sensitivity analyses were carried out. Out of 4,415 studies screened, 49 studies were included. Test-retest reliability of schizoaffective disorder was consistently lower than that of schizophrenia (in 39 out of 42 studies), bipolar disorder (27/33), and unipolar depression (29/35). The mean difference in kappa between schizoaffective disorder and the other diagnoses was approximately 0.2, and mean Cohen's kappa for schizoaffective disorder was 0.50 (95% confidence interval: 0.40-0.59). While findings were unequivocal and homogeneous for schizoaffective disorder's diagnostic reliability relative to its three main differential diagnoses (dichotomous: smaller versus larger), heterogeneity was substantial for continuous measures, even after subgroup and sensitivity analyses. In clinical practice and research, schizoaffective disorder's comparatively low diagnostic reliability should lead to increased efforts to correctly diagnose the disorder. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Diagnostic methods in sepsis: the need of speed

    Directory of Open Access Journals (Sweden)

    Fernando Rodrigues Coelho

    2012-08-01

    Full Text Available OBJECTIVE: Sepsis is a common condition encountered in hospital environments. There is no effective treatment for sepsis, and it remains an important cause of death at intensive care units. This study aimed to discuss some methods that are available in clinics, and tests that have been recently developed for the diagnosis of sepsis. METHODS: A systematic review was performed through the analysis of the following descriptors: sepsis, diagnostic methods, biological markers, and cytokines. RESULTS: The deleterious effects of sepsis are caused by an imbalance between the invasiveness of the pathogen and the ability of the host to mount an effective immune response. Consequently, the host's immune surveillance fails to eliminate the pathogen, allowing it to spread. Moreover, there is a pro-inflammatory mediator release, inappropriate activation of the coagulation and complement cascades, leading to dysfunction of multiple organs and systems. The difficulty achieve total recovery of the patient is explainable. There is an increased incidence of sepsis worldwide due to factors such as aging population, larger number of surgeries, and number of microorganisms resistant to existing antibiotics. CONCLUSION: The search for new diagnostic markers associated with increased risk of sepsis development and molecules that can be correlated to certain steps of sepsis is becoming necessary. This would allow for earlier diagnosis, facilitate patient prognosis characterization, and prediction of possible evolution of each case. All other markers are regrettably constrained to research units.

  11. Are the classic diagnostic methods in mycology still state of the art?

    Science.gov (United States)

    Wiegand, Cornelia; Bauer, Andrea; Brasch, Jochen; Nenoff, Pietro; Schaller, Martin; Mayser, Peter; Hipler, Uta-Christina; Elsner, Peter

    2016-05-01

    The diagnostic workup of cutaneous fungal infections is traditionally based on microscopic KOH preparations as well as culturing of the causative organism from sample material. Another possible option is the detection of fungal elements by dermatohistology. If performed correctly, these methods are generally suitable for the diagnosis of mycoses. However, the advent of personalized medicine and the tasks arising therefrom require new procedures marked by simplicity, specificity, and swiftness. The additional use of DNA-based molecular techniques further enhances sensitivity and diagnostic specificity, and reduces the diagnostic interval to 24-48 hours, compared to weeks required for conventional mycological methods. Given the steady evolution in the field of personalized medicine, simple analytical PCR-based systems are conceivable, which allow for instant diagnosis of dermatophytes in the dermatology office (point-of-care tests). © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  12. Identification of Nasal Bone Fractures on Conventional Radiography and Facial CT: Comparison of the Diagnostic Accuracy in Different Imaging Modalities and Analysis of Interobserver Reliability

    International Nuclear Information System (INIS)

    Baek, Hye Jin; Kim, Dong Wook; Ryu, Ji Hwa; Lee, Yoo Jin

    2013-01-01

    There has been no study to compare the diagnostic accuracy of an experienced radiologist with a trainee in nasal bone fracture. To compare the diagnostic accuracy between conventional radiography and computed tomography (CT) for the identification of nasal bone fractures and to evaluate the interobserver reliability between a staff radiologist and a trainee. A total of 108 patients who underwent conventional radiography and CT after acute nasal trauma were included in this retrospective study. Two readers, a staff radiologist and a second-year resident, independently assessed the results of the imaging studies. Of the 108 patients, the presence of a nasal bone fracture was confirmed in 88 (81.5%) patients. The number of non-depressed fractures was higher than the number of depressed fractures. In nine (10.2%) patients, nasal bone fractures were only identified on conventional radiography, including three depressed and six non-depressed fractures. CT was more accurate as compared to conventional radiography for the identification of nasal bone fractures as determined by both readers (P <0.05), all diagnostic indices of an experienced radiologist were similar to or higher than those of a trainee, and κ statistics showed moderate agreement between the two diagnostic tools for both readers. There was no statistical difference in the assessment of interobserver reliability for both imaging modalities in the identification of nasal bone fractures. For the identification of nasal bone fractures, CT was significantly superior to conventional radiography. Although a staff radiologist showed better values in the identification of nasal bone fracture and differentiation between depressed and non-depressed fractures than a trainee, there was no statistically significant difference in the interpretation of conventional radiography and CT between a radiologist and a trainee

  13. Advanced diagnostics and predictive maintenance to improve availability and reliability of ENEL plants

    Energy Technology Data Exchange (ETDEWEB)

    Cenci, V.; Ghironi, M.; Guidi, L.; Lauro, M.; Pestonesi, D. [ENEL (Italy). Generation and Energy Management Division

    2007-07-01

    This paper reviews the ENEL Generation and Energy Management strategy for diagnostics and predictive maintenance of power plants and provides a comprehensive description of effective applications and systems. Exploiting the most advanced information and communication technologies makes it possible to capture weak and hidden signals and powerful processing can be used to discover forewarning symptoms and identify anomalies both in the process and, above all, inside the devices. The following systems and applications are presented together with results and impact on plant profitability: expert system for the diagnostics of plant main machinery; advanced diagnostics of 'intelligent' fieldbus devices such as on/off valve motor-driven actuators, control-valve positioners and pneumatic actuators, transmitters; control loop and control valve diagnostics in order to investigate valve friction with an estimation of the residual time to failure; multisensorial diagnostics for coal transport and storage systems aimed at preventing firing and structural damages; and wireless sensor networks for the diagnostics of medium and small size components. 4 refs., 14 figs., 1 tab.

  14. Diagnostic accuracy of organ electrodermal diagnostics | Szopinski ...

    African Journals Online (AJOL)

    Objective. To estimate the diagnostic accuracy as well as the scope of utilisation of a new bio-electronic method of organ diagnostics. Design. Double-blind comparative study of the diagnostic results obtained by means of organ electrodermal diagnostics (OED) and clinical diagnoses, as a criterion standard. Setting.

  15. Use of urethral catheters for diagnostic peritoneal lavage in blunt ...

    African Journals Online (AJOL)

    Background: Diagnostic peritoneal lavage (DPL) has been reported to be a reliable diagnostic tool in assessing the need for liparotomy in blunt abdominal trauma (BAT) with a diagnostic accuracy of more thin 95% when using a peritoneal lavage catheter (PLC). The aim of this study was to determine the diagnostic ...

  16. A dynamic particle filter-support vector regression method for reliability prediction

    International Nuclear Information System (INIS)

    Wei, Zhao; Tao, Tao; ZhuoShu, Ding; Zio, Enrico

    2013-01-01

    Support vector regression (SVR) has been applied to time series prediction and some works have demonstrated the feasibility of its use to forecast system reliability. For accuracy of reliability forecasting, the selection of SVR's parameters is important. The existing research works on SVR's parameters selection divide the example dataset into training and test subsets, and tune the parameters on the training data. However, these fixed parameters can lead to poor prediction capabilities if the data of the test subset differ significantly from those of training. Differently, the novel method proposed in this paper uses particle filtering to estimate the SVR model parameters according to the whole measurement sequence up to the last observation instance. By treating the SVR training model as the observation equation of a particle filter, our method allows updating the SVR model parameters dynamically when a new observation comes. Because of the adaptability of the parameters to dynamic data pattern, the new PF–SVR method has superior prediction performance over that of standard SVR. Four application results show that PF–SVR is more robust than SVR to the decrease of the number of training data and the change of initial SVR parameter values. Also, even if there are trends in the test data different from those in the training data, the method can capture the changes, correct the SVR parameters and obtain good predictions. -- Highlights: •A dynamic PF–SVR method is proposed to predict the system reliability. •The method can adjust the SVR parameters according to the change of data. •The method is robust to the size of training data and initial parameter values. •Some cases based on both artificial and real data are studied. •PF–SVR shows superior prediction performance over standard SVR

  17. Methods to compute reliabilities for genomic predictions of feed intake

    Science.gov (United States)

    For new traits without historical reference data, cross-validation is often the preferred method to validate reliability (REL). Time truncation is less useful because few animals gain substantial REL after the truncation point. Accurate cross-validation requires separating genomic gain from pedigree...

  18. Verification of practicability of quantitative reliability evaluation method (De-BDA) in nuclear power plants

    International Nuclear Information System (INIS)

    Takahashi, Kinshiro; Yukimachi, Takeo.

    1988-01-01

    A variety of methods have been applied to study of reliability analysis in which human factors are included in order to enhance the safety and availability of nuclear power plants. De-BDA (Detailed Block Diagram Analysis) is one of such mehtods developed with the objective of creating a more comprehensive and understandable tool for quantitative analysis of reliability associated with plant operations. The practicability of this method has been verified by applying it to reliability analysis of various phases of plant operation as well as evaluation of enhanced man-machine interface in the central control room. (author)

  19. DEMO diagnostics and burn control

    Energy Technology Data Exchange (ETDEWEB)

    Biel, Wolfgang, E-mail: w.biel@fz-juelich.de [Institute of Energy and Climate Research, Forschungszentrum Jülich GmbH, Jülich (Germany); Department of Applied Physics, Ghent University (Belgium); Baar, Marco de [FOM-Institute DIFFER, Nieuwegein (Netherlands); Eindhoven University of Technology (Netherlands); Dinklage, Andreas [Max-Planck-Institut für Plasmaphysik, Greifswald (Germany); Felici, Federico [Eindhoven University of Technology (Netherlands); König, Ralf [Max-Planck-Institut für Plasmaphysik, Greifswald (Germany); Meister, Hans; Treutterer, Wolfgang [Max-Planck-Institut für Plasmaphysik, Garching (Germany); Wenninger, Ronald [Max-Planck-Institut für Plasmaphysik, Garching (Germany); EFDA Power Plant Physics and Technology, Garching (Germany)

    2015-10-15

    Highlights: • An initial concept for the DEMO diagnostic and control system is presented. • A preliminary list of control functions and candidate diagnostics is developed. • Challenges regarding disruptions, power exhaust and radiation control are highlighted. • The need for introducing realistic control margins is emphasized. • On outline of the future R&D plan is presented. - Abstract: The development of the control system for a tokamak demonstration fusion reactor (DEMO) faces unprecedented challenges. First, the requirements for control reliability and accuracy are more stringent than on existing fusion devices: any loss of plasma control on DEMO may result in a disruption which could damage the inner wall of the machine, while operating the device with larger margins against the operational limits would lead to a reduction of the electrical output power. Second, the performance of DEMO control is limited by space restrictions for the implementation of components (optimization of the tritium breeding rate), by lifetime issues for the front-end parts (neutron and gamma radiation, erosion and deposition acting on all components) and by slow, weak and indirect action of the available actuators (plasma shaping, heating and fuelling). The European DEMO conceptual design studies include the development of a reliable control system, since the details of the achievable plasma scenario and the machine design may depend on the actual performance of the control system. In the first phase of development, an initial understanding of the prime choices of diagnostic methods applicable to DEMO, implementation and performance issues, the interrelation with the plasma scenario definition, and the planning of necessary future R&D have been obtained.

  20. Application of system reliability analytical method, GO-FLOW

    International Nuclear Information System (INIS)

    Matsuoka, Takeshi; Fukuto, Junji; Mitomo, Nobuo; Miyazaki, Keiko; Matsukura, Hiroshi; Kobayashi, Michiyuki

    1999-01-01

    The Ship Research Institute proceed a developmental study on GO-FLOW method with various advancing functionalities for the system reliability analysis method occupying main parts of PSA (Probabilistic Safety Assessment). Here was attempted to intend to upgrade functionality of the GO-FLOW method, to develop an analytical function integrated with dynamic behavior analytical function, physical behavior and probable subject transfer, and to prepare a main accident sequence picking-out function. In 1997 fiscal year, in dynamic event-tree analytical system, an analytical function was developed by adding dependency between headings. In simulation analytical function of the accident sequence, main accident sequence of MRX for improved ship propulsion reactor became possible to be covered perfectly. And, input data for analysis was prepared with a function capable easily to set by an analysis operator. (G.K.)

  1. A method of bias correction for maximal reliability with dichotomous measures.

    Science.gov (United States)

    Penev, Spiridon; Raykov, Tenko

    2010-02-01

    This paper is concerned with the reliability of weighted combinations of a given set of dichotomous measures. Maximal reliability for such measures has been discussed in the past, but the pertinent estimator exhibits a considerable bias and mean squared error for moderate sample sizes. We examine this bias, propose a procedure for bias correction, and develop a more accurate asymptotic confidence interval for the resulting estimator. In most empirically relevant cases, the bias correction and mean squared error correction can be performed simultaneously. We propose an approximate (asymptotic) confidence interval for the maximal reliability coefficient, discuss the implementation of this estimator, and investigate the mean squared error of the associated asymptotic approximation. We illustrate the proposed methods using a numerical example.

  2. Advanced solutions for operational reliability improvements

    Energy Technology Data Exchange (ETDEWEB)

    Holmberg, K [VTT Manufacturing Technology, Espoo (Finland)

    1998-12-31

    A great number of new technical tools are today developed for improved operational reliability of machines and industrial equipment. Examples of such techniques and tools recently developed at the Technical Research Centre of Finland (VTT) are: metallographic approach for steam-piping lifetime estimation, an expert system AURORA for corrosion prediction and material selection, an automatic image-processing-based on-line wear particle analysis system, microsensors for condition monitoring, a condition monitoring and expert system, CEPDIA, for the diagnosis of centrifugal pumps, a machine tool analysis and diagnostic expert system, non-leakage magnetic fluid seals with extended lifetime and diamond-like surface coatings on components with decreased friction and wear properties. A hyperbook-supported holistic approach to problem solving in maintenance and reliability engineering has been developed to help the user achieve a holistic understanding of the problem and its relationships, to navigate among the several technical tools and methods available, and to find those suitable for his application. (orig.)

  3. Advanced solutions for operational reliability improvements

    Energy Technology Data Exchange (ETDEWEB)

    Holmberg, K. [VTT Manufacturing Technology, Espoo (Finland)

    1997-12-31

    A great number of new technical tools are today developed for improved operational reliability of machines and industrial equipment. Examples of such techniques and tools recently developed at the Technical Research Centre of Finland (VTT) are: metallographic approach for steam-piping lifetime estimation, an expert system AURORA for corrosion prediction and material selection, an automatic image-processing-based on-line wear particle analysis system, microsensors for condition monitoring, a condition monitoring and expert system, CEPDIA, for the diagnosis of centrifugal pumps, a machine tool analysis and diagnostic expert system, non-leakage magnetic fluid seals with extended lifetime and diamond-like surface coatings on components with decreased friction and wear properties. A hyperbook-supported holistic approach to problem solving in maintenance and reliability engineering has been developed to help the user achieve a holistic understanding of the problem and its relationships, to navigate among the several technical tools and methods available, and to find those suitable for his application. (orig.)

  4. Reliability of diagnosis and clinical efficacy of visceral osteopathy: a systematic review.

    Science.gov (United States)

    Guillaud, Albin; Darbois, Nelly; Monvoisin, Richard; Pinsault, Nicolas

    2018-02-17

    In 2010, the World Health Organization published benchmarks for training in osteopathy in which osteopathic visceral techniques are included. The purpose of this study was to identify and critically appraise the scientific literature concerning the reliability of diagnosis and the clinical efficacy of techniques used in visceral osteopathy. Databases MEDLINE, OSTMED.DR, the Cochrane Library, Osteopathic Research Web, Google Scholar, Journal of American Osteopathic Association (JAOA) website, International Journal of Osteopathic Medicine (IJOM) website, and the catalog of Académie d'ostéopathie de France website were searched through December 2017. Only inter-rater reliability studies including at least two raters or the intra-rater reliability studies including at least two assessments by the same rater were included. For efficacy studies, only randomized-controlled-trials (RCT) or crossover studies on unhealthy subjects (any condition, duration and outcome) were included. Risk of bias was determined using a modified version of the quality appraisal tool for studies of diagnostic reliability (QAREL) in reliability studies. For the efficacy studies, the Cochrane risk of bias tool was used to assess their methodological design. Two authors performed data extraction and analysis. Eight reliability studies and six efficacy studies were included. The analysis of reliability studies shows that the diagnostic techniques used in visceral osteopathy are unreliable. Regarding efficacy studies, the least biased study shows no significant difference for the main outcome. The main risks of bias found in the included studies were due to the absence of blinding of the examiners, an unsuitable statistical method or an absence of primary study outcome. The results of the systematic review lead us to conclude that well-conducted and sound evidence on the reliability and the efficacy of techniques in visceral osteopathy is absent. The review is registered PROSPERO 12th of December

  5. Mapping the different methods adopted for diagnostic imaging instruction at medical schools in Brazil.

    Science.gov (United States)

    Chojniak, Rubens; Carneiro, Dominique Piacenti; Moterani, Gustavo Simonetto Peres; Duarte, Ivone da Silva; Bitencourt, Almir Galvão Vieira; Muglia, Valdair Francisco; D'Ippolito, Giuseppe

    2017-01-01

    To map the different methods for diagnostic imaging instruction at medical schools in Brazil. In this cross-sectional study, a questionnaire was sent to each of the coordinators of 178 Brazilian medical schools. The following characteristics were assessed: teaching model; total course hours; infrastructure; numbers of students and professionals involved; themes addressed; diagnostic imaging modalities covered; and education policies related to diagnostic imaging. Of the 178 questionnaires sent, 45 (25.3%) were completed and returned. Of those 45 responses, 17 (37.8%) were from public medical schools, whereas 28 (62.2%) were from private medical schools. Among the 45 medical schools evaluated, the method of diagnostic imaging instruction was modular at 21 (46.7%), classic (independent discipline) at 13 (28.9%), hybrid (classical and modular) at 9 (20.0%), and none of the preceding at 3 (6.7%). Diagnostic imaging is part of the formal curriculum at 36 (80.0%) of the schools, an elective course at 3 (6.7%), and included within another modality at 6 (13.3%). Professors involved in diagnostic imaging teaching are radiologists at 43 (95.5%) of the institutions. The survey showed that medical courses in Brazil tend to offer diagnostic imaging instruction in courses that include other content and at different time points during the course. Radiologists are extensively involved in undergraduate medical education, regardless of the teaching methodology employed at the institution.

  6. The Diagnostic Value of ELISA Method for Pertussis in Children

    Directory of Open Access Journals (Sweden)

    O. P. Popova

    2016-01-01

    Full Text Available Because of low effectiveness of laboratory methods for diagnosing pertussis it is important to look for new ways of verification of this infection. The article presents the analysis of the diagnostic value of ELISA method, which involves the identification of antibodies of different isotypes (IgM, IgG, IgA to pertussis toxoid (PT and filamentous haemagglutinin (FHA. The study included 279 children: 114 were under 1 year of age, 165 — older than 1 year. The pertussis was confirmed in 74.3 ± 2.6% of patients by using ELISA method. A significant proportion of seronegative patients (46.1 ± 6.2 per cent was revealed in the group of patients under 1 year. The pattern of production of antibodies in unvaccinated children was different. It depended on the age of the children and timing of illness. A low proportion of diagnostically significant indicators of IgM-antibodies at 2—3 weeks of illness was typical for patients under 1 year of age (e.g. 6.7 ± 6.5% as compared to 20.0 ± 7.9% and 50.0 ± 15.3 — 1—3 and 4—6 years of age. The diagnosis of pertussis in children under 1 year of age was confirmed mainly by the detection of IgG, starting from the 4th week of the disease. In the examination of vaccinated children diagnostically significant levels of IgA and IgG were identified (even in the late stages of the disease. Thus, the results of the analysis show special significance of using ELISA method for the diagnosis of pertussis in vaccinated children.

  7. A New Method of Reliability Evaluation Based on Wavelet Information Entropy for Equipment Condition Identification

    International Nuclear Information System (INIS)

    He, Z J; Zhang, X L; Chen, X F

    2012-01-01

    Aiming at reliability evaluation of condition identification of mechanical equipment, it is necessary to analyze condition monitoring information. A new method of reliability evaluation based on wavelet information entropy extracted from vibration signals of mechanical equipment is proposed. The method is quite different from traditional reliability evaluation models that are dependent on probability statistics analysis of large number sample data. The vibration signals of mechanical equipment were analyzed by means of second generation wavelet package (SGWP). We take relative energy in each frequency band of decomposed signal that equals a percentage of the whole signal energy as probability. Normalized information entropy (IE) is obtained based on the relative energy to describe uncertainty of a system instead of probability. The reliability degree is transformed by the normalized wavelet information entropy. A successful application has been achieved to evaluate the assembled quality reliability for a kind of dismountable disk-drum aero-engine. The reliability degree indicates the assembled quality satisfactorily.

  8. Evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia.

    Science.gov (United States)

    Yimer, Mulat; Hailu, Tadesse; Mulu, Wondemagegn; Abera, Bayeh

    2015-12-26

    Although the sensitivity of Wet mount technique is questionable, it is the major diagnostic technique for routine diagnosis of intestinal parasitosis in Ethiopia. Therefore, the aim of this study was the evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia. A cross sectional study was conducted from May to June 2013. Single stool sample was processed for direct, Formol ether concentration (FEC) and Kato Katz methods. The sensitivity and negative predictive value (NPV) of diagnostic tests were calculated in terms of the "Gold" standard method (the combined result of the three methods altogether). A total of 422 school age children were participated in this study. The prevalence of intestinal parasites was high (74.6%) with Kato Katz technique. The sensitivity of Wet mount, FEC and Kato Katz tests against the Gold standard test was 48.9, 63.1 and 93.7%, respectively. Kato Katz technique revealed a better NPV 80.4 (80.1-80.6) as compared to the Wet mount (33.7%) and FEC techniques (41.3%). In this study, the Kato Katz technique outperformed the other two methods but the true values for sensitivity, specificity and diagnostic values are not known. Moreover, it is labor intensive and not easily accessible. Hence, it is preferable to use FEC technique to complement the Wet mount test.

  9. Planning of operation & maintenance using risk and reliability based methods

    DEFF Research Database (Denmark)

    Florian, Mihai; Sørensen, John Dalsgaard

    2015-01-01

    Operation and maintenance (OM) of offshore wind turbines contributes with a substantial part of the total levelized cost of energy (LCOE). The objective of this paper is to present an application of risk- and reliability-based methods for planning of OM. The theoretical basis is presented...

  10. Analysis of the reliability and reproducibility of goniometry compared to hand photogrammetry

    Science.gov (United States)

    de Carvalho, Rosana Martins Ferreira; Mazzer, Nilton; Barbieri, Claudio Henrique

    2012-01-01

    Objective: To evaluate the intra- and inter-examiner reliability and reproducibility of goniometry in relation to photogrammetry of hand, comparing the angles of thumb abduction, PIP joint flexion of the II finger and MCP joint flexion of the V finger. Methods: The study included 30 volunteers, who were divided into three groups: one group of 10 physiotherapy students, one group of 10 physiotherapists, and a third group of 10 therapists of the hand. Each examiner performed the measurements on the same hand mold, using the goniometer followed by two photogrammetry software programs; CorelDraw® and ALCimagem®. Results: The results revealed that the groups and the methods proposed presented inter-examiner reliability, generally rated as excellent (ICC 0.998 I.C. 95% 0.995 - 0.999). In the intra-examiner evaluation, an excellent level of reliability was found between the three groups. In the comparison between groups for each angle and each method, no significant differences were found between the groups for most of the measurements. Conclusion: Goniometry and photogrammetry are reliable and reproducible methods for evaluating measurements of the hand. However, due to the lack of similar references, detailed studies are needed to define the normal parameters between the methods in the joints of the hand. Level of Evidence II, Diagnostic Study. PMID:24453594

  11. A Comparison of Three Methods for the Analysis of Skin Flap Viability: Reliability and Validity.

    Science.gov (United States)

    Tim, Carla Roberta; Martignago, Cintia Cristina Santi; da Silva, Viviane Ribeiro; Dos Santos, Estefany Camila Bonfim; Vieira, Fabiana Nascimento; Parizotto, Nivaldo Antonio; Liebano, Richard Eloin

    2018-05-01

    Objective: Technological advances have provided new alternatives to the analysis of skin flap viability in animal models; however, the interrater validity and reliability of these techniques have yet to be analyzed. The present study aimed to evaluate the interrater validity and reliability of three different methods: weight of paper template (WPT), paper template area (PTA), and photographic analysis. Approach: Sixteen male Wistar rats had their cranially based dorsal skin flap elevated. On the seventh postoperative day, the viable tissue area and the necrotic area of the skin flap were recorded using the paper template method and photo image. The evaluation of the percentage of viable tissue was performed using three methods, simultaneously and independently by two raters. The analysis of interrater reliability and viability was performed using the intraclass correlation coefficient and Bland Altman Plot Analysis was used to visualize the presence or absence of systematic bias in the evaluations of data validity. Results: The results showed that interrater reliability for WPT, measurement of PTA, and photographic analysis were 0.995, 0.990, and 0.982, respectively. For data validity, a correlation >0.90 was observed for all comparisons made between the three methods. In addition, Bland Altman Plot Analysis showed agreement between the comparisons of the methods and the presence of systematic bias was not observed. Innovation: Digital methods are an excellent choice for assessing skin flap viability; moreover, they make data use and storage easier. Conclusion: Independently from the method used, the interrater reliability and validity proved to be excellent for the analysis of skin flaps' viability.

  12. A new method for analyzing diagnostic delay in gynecological cancer

    DEFF Research Database (Denmark)

    Vandborg, Mai Partridge; Edwards, Kasper; Kragtrup, Jakob

    2012-01-01

    AND METHODS: Six women with a diagnostic delay of 6 weeks or more before treatment of gynecological cancer at a specialized regional department (the Department of Gynecology and Obstetrics, Odense University Hospital, Denmark) were included in the study. Maps of existing processes were performed for each...

  13. A New Method for Analyzing Diagnostic Delay in Gynecological Cancer

    DEFF Research Database (Denmark)

    Vandborg, Mai Partridge; Edwards, Kasper; Kragstrup, Jakob

    2012-01-01

    AND METHODS: Six women with a diagnostic delay of 6 weeks or more before treatment of gynecological cancer at a specialized regional department (the Department of Gynecology and Obstetrics, Odense University Hospital, Denmark) were included in the study. Maps of existing processes were performed for each...

  14. Matrix-based system reliability method and applications to bridge networks

    International Nuclear Information System (INIS)

    Kang, W.-H.; Song Junho; Gardoni, Paolo

    2008-01-01

    Using a matrix-based system reliability (MSR) method, one can estimate the probabilities of complex system events by simple matrix calculations. Unlike existing system reliability methods whose complexity depends highly on that of the system event, the MSR method describes any general system event in a simple matrix form and therefore provides a more convenient way of handling the system event and estimating its probability. Even in the case where one has incomplete information on the component probabilities and/or the statistical dependence thereof, the matrix-based framework enables us to estimate the narrowest bounds on the system failure probability by linear programming. This paper presents the MSR method and applies it to a transportation network consisting of bridge structures. The seismic failure probabilities of bridges are estimated by use of the predictive fragility curves developed by a Bayesian methodology based on experimental data and existing deterministic models of the seismic capacity and demand. Using the MSR method, the probability of disconnection between each city/county and a critical facility is estimated. The probability mass function of the number of failed bridges is computed as well. In order to quantify the relative importance of bridges, the MSR method is used to compute the conditional probabilities of bridge failures given that there is at least one city disconnected from the critical facility. The bounds on the probability of disconnection are also obtained for cases with incomplete information

  15. Evaluating the reliability of multi-body mechanisms: A method considering the uncertainties of dynamic performance

    International Nuclear Information System (INIS)

    Wu, Jianing; Yan, Shaoze; Zuo, Ming J.

    2016-01-01

    Mechanism reliability is defined as the ability of a certain mechanism to maintain output accuracy under specified conditions. Mechanism reliability is generally assessed by the classical direct probability method (DPM) derived from the first order second moment (FOSM) method. The DPM relies strongly on the analytical form of the dynamic solution so it is not applicable to multi-body mechanisms that have only numerical solutions. In this paper, an indirect probability model (IPM) is proposed for mechanism reliability evaluation of multi-body mechanisms. IPM combines the dynamic equation, degradation function and Kaplan–Meier estimator to evaluate mechanism reliability comprehensively. Furthermore, to reduce the amount of computation in practical applications, the IPM is simplified into the indirect probability step model (IPSM). A case study of a crank–slider mechanism with clearance is investigated. Results show that relative errors between the theoretical and experimental results of mechanism reliability are less than 5%, demonstrating the effectiveness of the proposed method. - Highlights: • An indirect probability model (IPM) is proposed for mechanism reliability evaluation. • The dynamic equation, degradation function and Kaplan–Meier estimator are used. • Then the simplified form of indirect probability model is proposed. • The experimental results agree well with the predicted results.

  16. Simulation study on unfolding methods for diagnostic X-rays and mixed gamma rays

    International Nuclear Information System (INIS)

    Hashimoto, Makoto; Ohtaka, Masahiko; Ara, Kuniaki; Kanno, Ikuo; Imamura, Ryo; Mikami, Kenta; Nomiya, Seiichiro; Onabe, Hideaki

    2009-01-01

    A photon detector operating in current mode that can sense X-ray energy distribution has been reported. This detector consists of a row of several segment detectors. The energy distribution is derived using an unfolding technique. In this paper, comparisons of the unfolding techniques among error reduction, spectrum surveillance, and neural network methods are discussed through simulation studies on the detection of diagnostic X-rays and gamma rays emitted by a mixture of 137 Cs and 60 Co. For diagnostic X-ray measurement, the spectrum surveillance and neural network methods appeared promising, while the error reduction method yielded poor results. However, in the case of measuring mixtures of gamma rays, the error reduction method was both sufficient and effective. (author)

  17. Precision profiles and analytic reliability of radioimmunologic methods

    International Nuclear Information System (INIS)

    Yaneva, Z.; Popova, Yu.

    1991-01-01

    The aim of the present study is to investigate and compare some methods for creation of 'precision profiles' (PP) and to clarify their possibilities for determining the analytical reliability of RIA. Only methods without complicated mathematical calculations has been used. The reproducibility in serums with a concentration of the determinable hormone in the whole range of the calibration curve has been studied. The radioimmunoassay has been performed with TSH-RIA set (ex East Germany), and comparative evaluations - with commercial sets of HOECHST (Germany) and AMERSHAM (GB). Three methods for obtaining the relationship concentration (IU/l) -reproducibility (C.V.,%) are used and a comparison is made of their corresponding profiles: preliminary rough profile, Rodbard-PP and Ekins-PP. It is concluded that the creation of a precision profile is obligatory and the method of its construction does not influence the relationship's course. PP allows to determine concentration range giving stable results which improves the efficiency of the analitical work. 16 refs., 4 figs

  18. A defect-driven diagnostic method for machine tool spindles.

    Science.gov (United States)

    Vogl, Gregory W; Donmez, M Alkan

    2015-01-01

    Simple vibration-based metrics are, in many cases, insufficient to diagnose machine tool spindle condition. These metrics couple defect-based motion with spindle dynamics; diagnostics should be defect-driven. A new method and spindle condition estimation device (SCED) were developed to acquire data and to separate system dynamics from defect geometry. Based on this method, a spindle condition metric relying only on defect geometry is proposed. Application of the SCED on various milling and turning spindles shows that the new approach is robust for diagnosing the machine tool spindle condition.

  19. Does Radar Technology Support the Diagnosis of Pneumothorax? PneumoScan—A Diagnostic Point-of-Care Tool

    Directory of Open Access Journals (Sweden)

    T. Lindner

    2013-01-01

    Full Text Available Background. A nonrecognized pneumothorax (PTX may become a life-threatening tension PTX. A reliable point-of-care diagnostic tool could help in reduce this risk. For this purpose, we investigated the feasibility of the use of the PneumoScan, an innovative device based on micropower impulse radar (MIR. Patients and Methods. addition to a standard diagnostic protocol including clinical examination, chest X-ray (CXR, and computed tomography (CT, 24 consecutive patients with chest trauma underwent PneumoScan testing in the shock trauma room to exclude a PTX. Results. The application of the PneumoScan was simple, quick, and reliable without functional disorder. Clinical examination and CXR each revealed one and PneumoScan three out of altogether four PTXs (sensitivity 75%, specificity 100%, positive predictive value 100%, and negative predictive value 95%. The undetected PTX did not require intervention. Conclusion. The PneumoScan as a point-of-care device offers additional diagnostic value in patient management following chest trauma. Further studies with more patients have to be performed to evaluate the diagnostic accuracy of the device.

  20. Reliability Study Regarding the Use of Histogram Similarity Methods for Damage Detection

    Directory of Open Access Journals (Sweden)

    Nicoleta Gillich

    2013-01-01

    Full Text Available The paper analyses the reliability of three dissimilarity estimators to compare histograms, as support for a frequency-based damage detection method, able to identify structural changes in beam-like structures. First a brief presentation of the own developed damage detection method is made, with focus on damage localization. It consists actually in comparing a histogram derived from measurement results, with a large series of histograms, namely the damage location indexes for all locations along the beam, obtained by calculus. We tested some dissimilarity estimators like the Minkowski-form Distances, the Kullback-Leibler Divergence and the Histogram Intersection and found the Minkowski Distance as the method providing best results. It was tested for numerous locations, using real measurement results and with results artificially debased by noise, proving its reliability.

  1. Reliability Assessment of Active Distribution System Using Monte Carlo Simulation Method

    Directory of Open Access Journals (Sweden)

    Shaoyun Ge

    2014-01-01

    Full Text Available In this paper we have treated the reliability assessment problem of low and high DG penetration level of active distribution system using the Monte Carlo simulation method. The problem is formulated as a two-case program, the program of low penetration simulation and the program of high penetration simulation. The load shedding strategy and the simulation process were introduced in detail during each FMEA process. Results indicate that the integration of DG can improve the reliability of the system if the system was operated actively.

  2. Objective evaluation of cervical vertebral bone age' its reliability in comparison with hand-wrist bone age: by TW3 method.

    Science.gov (United States)

    Prasad, Cms Krishna; Reddy, Vamsi Nilay; Sreedevi, Gojja; Ponnada, Swaroopa Rani; Priya, K Padma; Naik, B Raveendra

    2013-09-01

    The aim of this study was to establish the validity of a new method for evaluating skeletal maturation by assessing the 3rd and 4th cervical vertebrae seen in the cephalometric radiograph. This study consisted of a sample of 50 patients in the age group of 8 to 14 years of age. Chronologically, they were divided into six groups, based on the age consisting of a minimum of six to a maximum of 10 subjects. All the patients included in the study were females. The selected subjects were clinically examined and then age and date of birth of the patient in years and months was noted. Then lateral cephalograms and hand-wrist radiographs of the patient were taken on the same day with good clarity and contrast. The results suggested that cervical vertebral bone age on cephalometric radiographs calculated with this method is as reliable at estimating bone age as is the Tanner-Whitehouse 3 (TW3) method on hand-wrist radiographs. By determining the cervical vertebral bone age, skeletal maturity can be evaluated in a detailed and objective manner with cephalometric radiographs. The ability to accurately appraise skeletal maturity from cervical vertebral maturation, without the need for additional radiographs, has the potential to improve orthodontic diagnostic and therapeutic decisions. The technique's simplicity and ease of use should encourage this method as a frst level diagnostic tool to assess skeletal maturation. Clinical signifcance: This study revealed that the timing and sequence of ossifcation of the bones in hand and wrist and cervical vertebrae were able to relate the skeletal development of the various skeletal maturity indicators to a child's development. This method provided a mean with which one can determine the skeletal maturity of a person and thereby determine whether the possibility of potential growth existed.

  3. Diagnostic Method of Diabetes Based on Support Vector Machine and Tongue Images

    Directory of Open Access Journals (Sweden)

    Jianfeng Zhang

    2017-01-01

    Full Text Available Objective. The purpose of this research is to develop a diagnostic method of diabetes based on standardized tongue image using support vector machine (SVM. Methods. Tongue images of 296 diabetic subjects and 531 nondiabetic subjects were collected by the TDA-1 digital tongue instrument. Tongue body and tongue coating were separated by the division-merging method and chrominance-threshold method. With extracted color and texture features of the tongue image as input variables, the diagnostic model of diabetes with SVM was trained. After optimizing the combination of SVM kernel parameters and input variables, the influences of the combinations on the model were analyzed. Results. After normalizing parameters of tongue images, the accuracy rate of diabetes predication was increased from 77.83% to 78.77%. The accuracy rate and area under curve (AUC were not reduced after reducing the dimensions of tongue features with principal component analysis (PCA, while substantially saving the training time. During the training for selecting SVM parameters by genetic algorithm (GA, the accuracy rate of cross-validation was grown from 72% or so to 83.06%. Finally, we compare with several state-of-the-art algorithms, and experimental results show that our algorithm has the best predictive accuracy. Conclusions. The diagnostic method of diabetes on the basis of tongue images in Traditional Chinese Medicine (TCM is of great value, indicating the feasibility of digitalized tongue diagnosis.

  4. Reliability testing of tendon disease using two different scanning methods in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Bruyn, George A W; Möller, Ingrid; Garrido, Jesus

    2012-01-01

    To assess the intra- and interobserver reliability of musculoskeletal ultrasonography (US) in detecting inflammatory and destructive tendon abnormalities in patients with RA using two different scanning methods.......To assess the intra- and interobserver reliability of musculoskeletal ultrasonography (US) in detecting inflammatory and destructive tendon abnormalities in patients with RA using two different scanning methods....

  5. Reliability and Validity of Prototype Diagnosis for Adolescent Psychopathology.

    Science.gov (United States)

    Haggerty, Greg; Zodan, Jennifer; Mehra, Ashwin; Zubair, Ayyan; Ghosh, Krishnendu; Siefert, Caleb J; Sinclair, Samuel J; DeFife, Jared

    2016-04-01

    The current study investigated the interrater reliability and validity of prototype ratings of 5 common adolescent psychiatric disorders: attention-deficit/hyperactivity disorder, conduct disorder, major depressive disorder, generalized anxiety disorder, and posttraumatic stress disorder. One hundred fifty-seven adolescent inpatient participants consented to participate in this study. We compared ratings from 2 inpatient clinicians, blinded to each other's ratings and patient measures, after their separate initial diagnostic interview to assess interrater reliability. Prototype ratings completed by clinicians after their initial diagnostic interview with adolescent inpatients and outpatients were compared with patient-reported behavior problems and parents' report of their child's behavioral problems. Prototype ratings demonstrated good interrater reliability. Clinicians' prototype ratings showed predicted relationships with patient-reported behavior problems and parent-reported behavior problems. Prototype matching seems to be a possible alternative for psychiatric diagnosis. Prototype ratings showed good interrater reliability based on clinicians unique experiences with the patient (as opposed to video-/audio-recorded material) with no training.

  6. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    International Nuclear Information System (INIS)

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE's nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer

  7. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE`s nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer.

  8. A Systematic Review of Statistical Methods Used to Test for Reliability of Medical Instruments Measuring Continuous Variables

    Directory of Open Access Journals (Sweden)

    Rafdzah Zaki

    2013-06-01

    Full Text Available   Objective(s: Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice.   Materials and Methods: In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. Results: The Intra-class Correlation Coefficient (ICC is the most popular method with 25 (60% studies having used this method followed by the comparing means (8 or 19%. Out of 25 studies using the ICC, only 7 (28% reported the confidence intervals and types of ICC used. Most studies (71% also tested the agreement of instruments. Conclusion: This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  9. A Sequential Kriging reliability analysis method with characteristics of adaptive sampling regions and parallelizability

    International Nuclear Information System (INIS)

    Wen, Zhixun; Pei, Haiqing; Liu, Hai; Yue, Zhufeng

    2016-01-01

    The sequential Kriging reliability analysis (SKRA) method has been developed in recent years for nonlinear implicit response functions which are expensive to evaluate. This type of method includes EGRA: the efficient reliability analysis method, and AK-MCS: the active learning reliability method combining Kriging model and Monte Carlo simulation. The purpose of this paper is to improve SKRA by adaptive sampling regions and parallelizability. The adaptive sampling regions strategy is proposed to avoid selecting samples in regions where the probability density is so low that the accuracy of these regions has negligible effects on the results. The size of the sampling regions is adapted according to the failure probability calculated by last iteration. Two parallel strategies are introduced and compared, aimed at selecting multiple sample points at a time. The improvement is verified through several troublesome examples. - Highlights: • The ISKRA method improves the efficiency of SKRA. • Adaptive sampling regions strategy reduces the number of needed samples. • The two parallel strategies reduce the number of needed iterations. • The accuracy of the optimal value impacts the number of samples significantly.

  10. Screening, sensitivity, and uncertainty for the CREAM method of Human Reliability Analysis

    International Nuclear Information System (INIS)

    Bedford, Tim; Bayley, Clare; Revie, Matthew

    2013-01-01

    This paper reports a sensitivity analysis of the Cognitive Reliability and Error Analysis Method for Human Reliability Analysis. We consider three different aspects: the difference between the outputs of the Basic and Extended methods, on the same HRA scenario; the variability in outputs through the choices made for common performance conditions (CPCs); and the variability in outputs through the assignment of choices for cognitive function failures (CFFs). We discuss the problem of interpreting categories when applying the method, compare its quantitative structure to that of first generation methods and discuss also how dependence is modelled with the approach. We show that the control mode intervals used in the Basic method are too narrow to be consistent with the Extended method. This motivates a new screening method that gives improved accuracy with respect to the Basic method, in the sense that (on average) halves the uncertainty associated with the Basic method. We make some observations on the design of a screening method that are generally applicable in Risk Analysis. Finally, we propose a new method of combining CPC weights with nominal probabilities so that the calculated probabilities are always in range (i.e. between 0 and 1), while satisfying sensible properties that are consistent with the overall CREAM method

  11. Pulmonary Exacerbation Score in Cystlc Fibrosis Patients: Reliability and Validity Testing

    OpenAIRE

    Keller, F.

    2016-01-01

    Background: Lung disease in cystic fibrosis (CF) is characterized by recurrent pulmonary exacerbations (PEs), but consensus on diagnostic criteria for PE is lacking. The use of a consistent definition of PE as an outcome measure in CF clinical trials would allow meaningful comparison across centers. The aim of this study was to assess the reliability and validity of a simplified version of the Seattle Pulmonary Exacerbation Score (SPEX). Materials and Methods: A cross-sectional observational ...

  12. Note: Additionally refined new possibilities of plasma probe diagnostics

    Science.gov (United States)

    Riaby, V. A.; Savinov, V. P.; Masherov, P. E.; Yakunin, V. G.

    2018-03-01

    In two previous Notes published in this journal, a method of measuring probe sheath thickness and ion mass was described using Langmuir probe diagnostics in low pressure xenon plasma close to Maxwellian substance. According to the first Note, this method includes two stages: (i) in a special experiment with known ion mass, the Bohm and Child-Langmuir-Boguslavsky (CLB) equations for cylindrical Langmuir probes used in this xenon plasma were solved jointly to determine the probe sheath thicknesses and Bohm coefficient CBCyl ≈ 1.13; and (ii) in a general experiment, with known CBCyl, the same equations could be solved to obtain the probe sheath thicknesses and the mean ion mass. In the second Note, the (i) stage of this method was refined: the results of the CLB probe sheath model application, which were termed "evaluations," were corrected using the step-front probe sheath model, which was closer to reality in the special experiment with the xenon plasma. This process resulted in a Bohm coefficient of CBCyl ≈ 1.23 for the cylindrical probe. In the present Note, corrected xenon plasma parameters without the influence of the bare probe protective shield were used for the (i) stage of this diagnostic method. This action also refined the Bohm coefficient, lowering it to CBCyl ≈ 0.745 for cylindrical probes. This advance makes the new diagnostics method more objective and reliable.

  13. Assessment of reliability of Greulich and Pyle (gp) method for ...

    African Journals Online (AJOL)

    Background: Greulich and Pyle standards are the most widely used age estimation standards all over the world. The applicability of the Greulich and Pyle standards to populations which differ from their reference population is often questioned. This study aimed to assess the reliability of Greulich and Pyle (GP) method for ...

  14. Proceeding of 35th domestic symposium on applications of structural reliability and risk assessment methods to nuclear power plants

    International Nuclear Information System (INIS)

    2005-06-01

    As the 35th domestic symposium of Atomic Energy Research Committee, the Japan Welding Engineering Society, the symposium was held titled as Applications of structural reliability/risk assessment methods to nuclear energy'. Six speakers gave lectures titled as 'Structural reliability and risk assessment methods', 'Risk-informed regulation of US nuclear energy and role of probabilistic risk assessment', 'Reliability and risk assessment methods in chemical plants', 'Practical structural design methods based on reliability in architectural and civil areas', 'Maintenance activities based on reliability in thermal power plants' and 'LWR maintenance strategies based on Probabilistic Fracture Mechanics'. (T. Tanaka)

  15. Proposed diagnostic criteria for internet addiction.

    Science.gov (United States)

    Tao, Ran; Huang, Xiuqin; Wang, Jinan; Zhang, Huimin; Zhang, Ying; Li, Mengchen

    2010-03-01

    The objective of this study was to develop diagnostic criteria for internet addiction disorder (IAD) and to evaluate the validity of our proposed diagnostic criteria for discriminating non-dependent from dependent internet use in the general population. This study was conducted in three stages: the developmental stage (110 subjects in the survey group; 408 subjects in the training group), where items of the proposed diagnostic criteria were developed and tested; the validation stage (n = 405), where the proposed criteria were evaluated for criterion-related validity; and the clinical stage (n = 150), where the criteria and the global clinical impression of IAD were evaluated by more than one psychiatrist to determine inter-rater reliability. The proposed internet addiction diagnostic criteria consisted of symptom criterion (seven clinical symptoms of IAD), clinically significant impairment criterion (functional and psychosocial impairments), course criterion (duration of addiction lasting at least 3 months, with at least 6 hours of non-essential internet usage per day) and exclusion criterion (exclusion of dependency attributed to psychotic disorders). A diagnostic score of 2 + 1, where the first two symptoms (preoccupation and withdrawal symptoms) and at least one of the five other symptoms (tolerance, lack of control, continued excessive use despite knowledge of negative effects/affects, loss of interests excluding internet, and use of the internet to escape or relieve a dysphoric mood) was established. Inter-rater reliability was 98%. Our findings suggest that the proposed diagnostic criteria may be useful for the standardization of diagnostic criteria for IAD.

  16. Diagnostic technology and an expert system for photovoltaic systems using the learning method

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, Yasuhiro; Kishi, Hitoshi; Hagihara, Ryuzou; Tanaka, Toshiya; Kozuma, Shinichi; Ishida, Takeo; Waki, Masahiro; Tanaka, Makoto; Kiyama, Seiichi [SANYO Electric Co. Ltd., New Materials Research Center, Moriguchi City, Osaka (Japan)

    2003-02-01

    Diagnostic technology for photovoltaic (PV) systems was developed, using the learning method to take each site's conditions into account. This technology employs diagnostic criteria databases to analyze data acquired from the PV systems. These criteria are updated monthly for each site using analyzed data. To check the shadows on the PV modules and pyranometer, the sophisticated verification method was also applied to this technology. After the diagnosis, a basket method provides maintenance advice for the PV systems. Based on the results of precise diagnoses, this expert system offers quick and proper maintenance advice within a few minutes. This technology is highly useful, because it greatly simplifies the servicing and maintenance of PV systems. (Author)

  17. Calculation of radiation exposure in diagnostic radiology. Method and surveys

    International Nuclear Information System (INIS)

    Duvauferrier, R.; Ramee, A.; Ezzeldin, K.; Guibert, J.L.

    1984-01-01

    A computerized method for evaluating the radiation exposure of the main target organs during various diagnostic radiologic procedures is described. This technique was used for educational purposes: study of exposure variations according to the technical modalities of a given procedure, and study of exposure variations according to various technical protocols (IVU, EGD barium study, etc.). This method was also used for studying exposure of patients during hospitalization in the Rennes Regional Hospital Center (France) in 1982, according to departments (urology, neurology, etc.). This method and results of these three studies are discussed [fr

  18. Reliability analysis of idealized tunnel support system using probability-based methods with case studies

    Science.gov (United States)

    Gharouni-Nik, Morteza; Naeimi, Meysam; Ahadi, Sodayf; Alimoradi, Zahra

    2014-06-01

    In order to determine the overall safety of a tunnel support lining, a reliability-based approach is presented in this paper. Support elements in jointed rock tunnels are provided to control the ground movement caused by stress redistribution during the tunnel drive. Main support elements contribute to stability of the tunnel structure are recognized owing to identify various aspects of reliability and sustainability in the system. The selection of efficient support methods for rock tunneling is a key factor in order to reduce the number of problems during construction and maintain the project cost and time within the limited budget and planned schedule. This paper introduces a smart approach by which decision-makers will be able to find the overall reliability of tunnel support system before selecting the final scheme of the lining system. Due to this research focus, engineering reliability which is a branch of statistics and probability is being appropriately applied to the field and much effort has been made to use it in tunneling while investigating the reliability of the lining support system for the tunnel structure. Therefore, reliability analysis for evaluating the tunnel support performance is the main idea used in this research. Decomposition approaches are used for producing system block diagram and determining the failure probability of the whole system. Effectiveness of the proposed reliability model of tunnel lining together with the recommended approaches is examined using several case studies and the final value of reliability obtained for different designing scenarios. Considering the idea of linear correlation between safety factors and reliability parameters, the values of isolated reliabilities determined for different structural components of tunnel support system. In order to determine individual safety factors, finite element modeling is employed for different structural subsystems and the results of numerical analyses are obtained in

  19. Study of methodology diversification in diagnostics

    International Nuclear Information System (INIS)

    Suda, Kazunori; Yonekawa, Tsuyoshi; Yoshikawa, Shinji; Hasegawa, Makoto

    1999-03-01

    There are several research activities to enhance safety and reliability of nuclear power plant operation and maintenance. We are developing a concept of an autonomous operation system where the role of operators is replaced with artificial intelligence. The purpose of the study described in this report is to develop a operator support system in abnormal plant situations. Conventionally, diagnostic modules based on individual methodology such as expert system have been developed and verified. In this report, methodology diversification is considered to integrate diagnostic modules which performance are confirmed using information processing technique. Technical issues to be considered in diagnostic methodology diversification are; 1)reliability of input data, 2)diversification of knowledge models, algorithms and reasoning schemes, 3)mutual complement and robustness. The diagnostic module utilizing the different approaches defined along with strategy of diversification was evaluated using fast breeder plant simulator. As a result, we confirmed that any singular diagnostic module can not meet accuracy criteria for the entire set of anomaly events. In contrast with this, we confirmed that every abnormality could be precisely diagnosed by a mutual combination. In other words, legitimacy of approach selected by strategy of diversification was shown, and methodology diversification attained clear efficiency for abnormal diagnosis. It has been also confirmed that the diversified diagnostic system implemented in this study is able to maintain its accuracy even in case that encountered scale of abnormality is different from reference cases embedded in the knowledge base. (author)

  20. Diagnostic Methods for Feline Coronavirus: A Review

    Directory of Open Access Journals (Sweden)

    Saeed Sharif

    2010-01-01

    Full Text Available Feline coronaviruses (FCoVs are found throughout the world. Infection with FCoV can result in a diverse range of signs from clinically inapparent infections to a highly fatal disease called feline infectious peritonitis (FIP. FIP is one of the most serious viral diseases of cats. While there is neither an effective vaccine, nor a curative treatment for FIP, a diagnostic protocol for FCoV would greatly assist in the management and control of the virus. Clinical findings in FIP are non-specific and not helpful in making a differential diagnosis. Haematological and biochemical abnormalities in FIP cases are also non-specific. The currently available serological tests have low specificity and sensitivity for detection of active infection and cross-react with FCoV strains of low pathogenicity, the feline enteric coronaviruses (FECV. Reverse transcriptase polymerase chain reaction (RT-PCR has been used to detect FCoV and is rapid and sensitive, but results must be interpreted in the context of clinical findings. At present, a definitive diagnosis of FIP can be established only by histopathological examination of biopsies. This paper describes and compares diagnostic methods for FCoVs and includes a brief account of the virus biology, epidemiology, and pathogenesis.

  1. Studies on the diagnostic accuracy of lymphography

    International Nuclear Information System (INIS)

    Luening, M.; Stargardt, A.; Abet, L.

    1979-01-01

    Contradictory reports in the literature on the reliability of lymphography stimulated the authors to test the diagnostic accuracy, employing methods which are approximately analogous to practice, using carcinoma of the cervix as the model on which the study was carried out. Using 21 observers it was found that there was no correlation between their experience and on-target accuracy of the diagnosis. Good observers obtained an accuracy of 85% with good proportions between sensitivity in the recognition of detail, specificity and readiness to arrive at a decision on the basis of discriminatory ability. With the help of the concept of the ROC curves, the position taken up by the observers in respect of diagnostic decisions, and a complex manner of assessing the various characteristic factors determining diagnostic accuracy, are demonstrated. This form of test, which permits manipulation of different variants of diagnosis, is recommended, among other things, for performance control at the end of training and continuing education courses in other fields of x-ray diagnosis as well. (orig.) [de

  2. The study of diagnostic accuracy of chest nodules by using different compression methods

    International Nuclear Information System (INIS)

    Liang Zhigang; Kuncheng, L.I.; Zhang Jinghong; Liu Shuliang

    2005-01-01

    Background: The purpose of this study was to compare the diagnostic accuracy of small nodules in the chest by using different compression methods. Method: Two radiologists with 5 years experience twice interpreted 39 chest images by using lossless and lossy compression methods. The time interval was 3 weeks. Each time the radiologists interpreted one kind of compressed images. The image browser used the Unisight software provided by Atlastiger Company in Shanghai. The interpreting results were analyzed by the ROCKIT software and the ROC curves were painted by Excel 2002. Results: In studies of receiver operating characteristics for scoring the presence or absence of nodules, the images with lossy compression method showed no statistical difference as compared with the images with lossless compression method. Conclusion: The diagnostic accuracy of chest nodules by using the lossless and lossy compression methods had no significant difference, we could use the lossy compression method to transmit and archive the chest images with nodules

  3. External laryngeal injuries in children--comparison of diagnostic methods.

    Science.gov (United States)

    Zawadzka-Glos, L; Jakubowska, A; Frackiewicz, M; Brzewski, M

    2013-09-01

    The injuries of the larynx constitute around 1% of all injuries. The great majority of the injuries of the larynx happens during playing. The effects of these injuries may appear insignificant however, not always the direct clinical symptoms correlate with the degree of respiratory tract failure. The symptoms of laryngeal injuries depend on the extension and strength of the trauma and always relate to impair patency of respiratory tract. The aim of the study is to compare two diagnostic methods: laryngoscopy and ultrasonography in evaluation of laryngeal injuries in children. In the Department of Pediatric Otolaryngology, Medical University of Warsaw, in the period between 2004 and 2010 there were hospitalised 15 children with external injury of the larynx. From among 15 hospitalized children, 7 were qualified as not serious trauma and were treated preservatively and the other 8 as sever trauma. The mechanism of traumas was diverse. Dyspnea was a predominating symptom, the others included hoarsness, change in voice quality, even aphonia, pain while speaking and swallowing, cough and hemoptysis. Direct laryngoscopy is a standard in diagnostics of the injuries of the larynx. Ultrasonography of the larynx is recommended in every case of laryngeal injury as an additional non-invasive complementary diagnostic examination. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  4. method and container for production of diagnostic scanning agents

    International Nuclear Information System (INIS)

    Ruddock, C.F.

    1979-01-01

    The pertechnetate ion containing the technetium-99m isotope has limited applications in diagnostic scanning because it does not readily form complexes with materials which locate in specific parts of the body. Stannous salts have been widely used to reduce the pertechnetate to a form which readily complexes with materials. In the present invention, both a container and a more suitable metal reducing agent are discussed for transforming the technetium in pertechnetate for diagnostic scanning use. The vessel contains tin or a tin-containing alloy as a reducing agent for the pertechnetate and a complexant for the reduced technetium; all contents are sterile and dry. The present invention is advantageous over the stannous salts method since (1) problems of stannous salt instability during production, storage and after labelling are eliminated; (2) production procedures are simplified; (3) it is not essential to nitrogen purge vials before sterilisation; (4) it reduces toxicity; (5) the shelf life of diagnostic scanning kits may be dramatically improved; (6) the metal reducing agent may be sterilised by γ-irradiation without deteriorating; (7) the labelling technique can be performed over a wide pH range; and (8) the technique should be unaffected by technetium-99 in the technetium-99m. (U.K.)

  5. Diagnostics on LALR(k) conflicts based on a method for LR(k) testing

    DEFF Research Database (Denmark)

    Kristensen, Bent Bruun; Madsen, Ole Lehrmann

    1981-01-01

    A user of an LALR(k) parser generator system may have difficulties in understanding how a given LALR(k) conflict is generated. This is especially difficult if the conflict does not correspond to an LR(k) conflict. A practical method for giving informative diagnostics on LALR(k) conflicts is prese......A user of an LALR(k) parser generator system may have difficulties in understanding how a given LALR(k) conflict is generated. This is especially difficult if the conflict does not correspond to an LR(k) conflict. A practical method for giving informative diagnostics on LALR(k) conflicts...

  6. Intrarater and interrater reliability for measurements in videofluoroscopy of swallowing

    International Nuclear Information System (INIS)

    Baijens, Laura; Barikroo, Ali; Pilz, Walmari

    2013-01-01

    Objective: Intrarater and interrater reliability is crucial to the quality of diagnostic and therapy-effect studies. This paper reports on a systematic review of studies on intrarater and interrater reliability for measurements in videofluoroscopy of swallowing. The aim of this review was to summarize and qualitatively analyze published studies on that topic. Materials and methods: Those published up to March 2013 were found through a comprehensive electronic database search using PubMed, Embase, and The Cochrane Library. Two reviewers independently assessed the studies using strict inclusion criteria. Results: Nineteen studies were included and then qualitatively analyzed. In several of these, methodological problems were found. Moreover, intrarater and interrater reliability varied with the measure applied. A meta-analysis was not carried out as studies were not of sufficient quality to warrant doing so. Conclusion: In order to achieve reliable measurements in videofluoroscopy of swallowing, it is recommended that raters use well-defined guidelines for the levels of ordinal visuoperceptual variables. Furthermore, in order to make the measurements reliable (intrarater and interrater) it is recommended that, following protocolled pre-experimental training, the raters should have maximum consensus about the definition of the measured variables

  7. Intrarater and interrater reliability for measurements in videofluoroscopy of swallowing

    Energy Technology Data Exchange (ETDEWEB)

    Baijens, Laura, E-mail: laura.baijens@mumc.nl [Department of Otorhinolaryngology, Head and Neck Surgery, Maastricht University Medical Center, Maastricht (Netherlands); Barikroo, Ali, E-mail: a.Barikroo@ufl.edu [Swallowing Research Laboratory, Department of Speech, Language and Hearing Sciences, College of Public Health and Health Professions, University of Florida, Gainesville, FL (United States); Pilz, Walmari, E-mail: walmari.pilz@mumc.nl [Department of Otorhinolaryngology, Head and Neck Surgery, Maastricht University Medical Center, Maastricht (Netherlands)

    2013-10-01

    Objective: Intrarater and interrater reliability is crucial to the quality of diagnostic and therapy-effect studies. This paper reports on a systematic review of studies on intrarater and interrater reliability for measurements in videofluoroscopy of swallowing. The aim of this review was to summarize and qualitatively analyze published studies on that topic. Materials and methods: Those published up to March 2013 were found through a comprehensive electronic database search using PubMed, Embase, and The Cochrane Library. Two reviewers independently assessed the studies using strict inclusion criteria. Results: Nineteen studies were included and then qualitatively analyzed. In several of these, methodological problems were found. Moreover, intrarater and interrater reliability varied with the measure applied. A meta-analysis was not carried out as studies were not of sufficient quality to warrant doing so. Conclusion: In order to achieve reliable measurements in videofluoroscopy of swallowing, it is recommended that raters use well-defined guidelines for the levels of ordinal visuoperceptual variables. Furthermore, in order to make the measurements reliable (intrarater and interrater) it is recommended that, following protocolled pre-experimental training, the raters should have maximum consensus about the definition of the measured variables.

  8. Schizoaffective disorder - The reliability of its clinical diagnostic use

    DEFF Research Database (Denmark)

    Vollmer-Larsen, A.; Jacobsen, T.B.; Hemmingsen, R.

    2006-01-01

    OBJECTIVE: Patients with psychoses often suffer from affective symptoms. The originally broad concept of schizoaffective disorder (SAD) has been significantly narrowed, transformed into a convoluted set of criteria both in the ICD-10 and DSM-IV. We examined the reliability of the clinical use...

  9. Improving statistical inference on pathogen densities estimated by quantitative molecular methods: malaria gametocytaemia as a case study.

    Science.gov (United States)

    Walker, Martin; Basáñez, María-Gloria; Ouédraogo, André Lin; Hermsen, Cornelus; Bousema, Teun; Churcher, Thomas S

    2015-01-16

    Quantitative molecular methods (QMMs) such as quantitative real-time polymerase chain reaction (q-PCR), reverse-transcriptase PCR (qRT-PCR) and quantitative nucleic acid sequence-based amplification (QT-NASBA) are increasingly used to estimate pathogen density in a variety of clinical and epidemiological contexts. These methods are often classified as semi-quantitative, yet estimates of reliability or sensitivity are seldom reported. Here, a statistical framework is developed for assessing the reliability (uncertainty) of pathogen densities estimated using QMMs and the associated diagnostic sensitivity. The method is illustrated with quantification of Plasmodium falciparum gametocytaemia by QT-NASBA. The reliability of pathogen (e.g. gametocyte) densities, and the accompanying diagnostic sensitivity, estimated by two contrasting statistical calibration techniques, are compared; a traditional method and a mixed model Bayesian approach. The latter accounts for statistical dependence of QMM assays run under identical laboratory protocols and permits structural modelling of experimental measurements, allowing precision to vary with pathogen density. Traditional calibration cannot account for inter-assay variability arising from imperfect QMMs and generates estimates of pathogen density that have poor reliability, are variable among assays and inaccurately reflect diagnostic sensitivity. The Bayesian mixed model approach assimilates information from replica QMM assays, improving reliability and inter-assay homogeneity, providing an accurate appraisal of quantitative and diagnostic performance. Bayesian mixed model statistical calibration supersedes traditional techniques in the context of QMM-derived estimates of pathogen density, offering the potential to improve substantially the depth and quality of clinical and epidemiological inference for a wide variety of pathogens.

  10. Comprehensive reliability allocation method for CNC lathes based on cubic transformed functions of failure mode and effects analysis

    Science.gov (United States)

    Yang, Zhou; Zhu, Yunpeng; Ren, Hongrui; Zhang, Yimin

    2015-03-01

    Reliability allocation of computerized numerical controlled(CNC) lathes is very important in industry. Traditional allocation methods only focus on high-failure rate components rather than moderate failure rate components, which is not applicable in some conditions. Aiming at solving the problem of CNC lathes reliability allocating, a comprehensive reliability allocation method based on cubic transformed functions of failure modes and effects analysis(FMEA) is presented. Firstly, conventional reliability allocation methods are introduced. Then the limitations of direct combination of comprehensive allocation method with the exponential transformed FMEA method are investigated. Subsequently, a cubic transformed function is established in order to overcome these limitations. Properties of the new transformed functions are discussed by considering the failure severity and the failure occurrence. Designers can choose appropriate transform amplitudes according to their requirements. Finally, a CNC lathe and a spindle system are used as an example to verify the new allocation method. Seven criteria are considered to compare the results of the new method with traditional methods. The allocation results indicate that the new method is more flexible than traditional methods. By employing the new cubic transformed function, the method covers a wider range of problems in CNC reliability allocation without losing the advantages of traditional methods.

  11. Microfluidic diagnostics for low-resource settings

    Science.gov (United States)

    Hawkins, Kenneth R.; Weigl, Bernhard H.

    2010-02-01

    Diagnostics for low-resource settings need to be foremost inexpensive, but also accurate, reliable, rugged and suited to the contexts of the developing world. Diagnostics for global health, based on minimally-instrumented, microfluidicsbased platforms employing low-cost disposables, has become a very active research area recently-thanks, in part, to new funding from the Bill & Melinda Gates Foundation, the National Institutes of Health, and other sources. This has led to a number of interesting prototype devices that are now in advanced development or clinical validation. These devices include disposables and instruments that perform multiplexed PCR-based assays for enteric, febrile, and vaginal diseases, as well as immunoassays for diseases such as malaria, HIV, and various sexually transmitted diseases. More recently, instrument-free diagnostic disposables based on isothermal nucleic-acid amplification have been developed. Regardless of platform, however, the search for truly low-cost manufacturing methods that would enable affordable systems (at volume, in the appropriate context) remains a significant challenge. Here we give an overview of existing platform development efforts, present some original research in this area at PATH, and reiterate a call to action for more.

  12. Diagnostic methods of fatty liver disease; Diagnostik der Fettleber

    Energy Technology Data Exchange (ETDEWEB)

    Kukuk, Guido Matthias; Sprinkart, Alois Martin; Traeber, Frank [Radiologische Universitaetsklinik Bonn (Germany). FE MRT

    2017-09-15

    Fatty liver disease is defined as an abnormal accumulation of lipids into the cytoplasm of hepatocytes. Different kinds of fatty liver diseases are becoming the most important etiologies of end-stage liver disease in the western world. Because fatty liver is a theoretically reversible process, timely and accurate diagnosis is a prerequisite for potential therapeutic options. This work describes major diagnostic methods and discusses particular advantages and disadvantages of various techniques.

  13. Comparison of methods for dependency determination between human failure events within human reliability analysis

    International Nuclear Information System (INIS)

    Cepis, M.

    2007-01-01

    The Human Reliability Analysis (HRA) is a highly subjective evaluation of human performance, which is an input for probabilistic safety assessment, which deals with many parameters of high uncertainty. The objective of this paper is to show that subjectivism can have a large impact on human reliability results and consequently on probabilistic safety assessment results and applications. The objective is to identify the key features, which may decrease of subjectivity of human reliability analysis. Human reliability methods are compared with focus on dependency comparison between Institute Jozef Stefan - Human Reliability Analysis (IJS-HRA) and Standardized Plant Analysis Risk Human Reliability Analysis (SPAR-H). Results show large differences in the calculated human error probabilities for the same events within the same probabilistic safety assessment, which are the consequence of subjectivity. The subjectivity can be reduced by development of more detailed guidelines for human reliability analysis with many practical examples for all steps of the process of evaluation of human performance. (author)

  14. Comparison of Methods for Dependency Determination between Human Failure Events within Human Reliability Analysis

    International Nuclear Information System (INIS)

    Cepin, M.

    2008-01-01

    The human reliability analysis (HRA) is a highly subjective evaluation of human performance, which is an input for probabilistic safety assessment, which deals with many parameters of high uncertainty. The objective of this paper is to show that subjectivism can have a large impact on human reliability results and consequently on probabilistic safety assessment results and applications. The objective is to identify the key features, which may decrease subjectivity of human reliability analysis. Human reliability methods are compared with focus on dependency comparison between Institute Jozef Stefan human reliability analysis (IJS-HRA) and standardized plant analysis risk human reliability analysis (SPAR-H). Results show large differences in the calculated human error probabilities for the same events within the same probabilistic safety assessment, which are the consequence of subjectivity. The subjectivity can be reduced by development of more detailed guidelines for human reliability analysis with many practical examples for all steps of the process of evaluation of human performance

  15. A Simple and Reliable Method of Design for Standalone Photovoltaic Systems

    Science.gov (United States)

    Srinivasarao, Mantri; Sudha, K. Rama; Bhanu, C. V. K.

    2017-06-01

    Standalone photovoltaic (SAPV) systems are seen as a promoting method of electrifying areas of developing world that lack power grid infrastructure. Proliferations of these systems require a design procedure that is simple, reliable and exhibit good performance over its life time. The proposed methodology uses simple empirical formulae and easily available parameters to design SAPV systems, that is, array size with energy storage. After arriving at the different array size (area), performance curves are obtained for optimal design of SAPV system with high amount of reliability in terms of autonomy at a specified value of loss of load probability (LOLP). Based on the array to load ratio (ALR) and levelized energy cost (LEC) through life cycle cost (LCC) analysis, it is shown that the proposed methodology gives better performance, requires simple data and is more reliable when compared with conventional design using monthly average daily load and insolation.

  16. A Hierarchical Reliability Control Method for a Space Manipulator Based on the Strategy of Autonomous Decision-Making

    Directory of Open Access Journals (Sweden)

    Xin Gao

    2016-01-01

    Full Text Available In order to maintain and enhance the operational reliability of a robotic manipulator deployed in space, an operational reliability system control method is presented in this paper. First, a method to divide factors affecting the operational reliability is proposed, which divides the operational reliability factors into task-related factors and cost-related factors. Then the models describing the relationships between the two kinds of factors and control variables are established. Based on this, a multivariable and multiconstraint optimization model is constructed. Second, a hierarchical system control model which incorporates the operational reliability factors is constructed. The control process of the space manipulator is divided into three layers: task planning, path planning, and motion control. Operational reliability related performance parameters are measured and used as the system’s feedback. Taking the factors affecting the operational reliability into consideration, the system can autonomously decide which control layer of the system should be optimized and how to optimize it using a control level adjustment decision module. The operational reliability factors affect these three control levels in the form of control variable constraints. Simulation results demonstrate that the proposed method can achieve a greater probability of meeting the task accuracy requirements, while extending the expected lifetime of the space manipulator.

  17. Diagnostic and therapeutic methods for occupational mercury poisoning

    International Nuclear Information System (INIS)

    Liu Zhanqi; Wang Xiuqin; Luo Futang

    2003-01-01

    A method of diagnosing and treating occupational mercury poisoning is reviewed in this paper. The treating measures for the chelating syndrome are also described. Based on his exposure history, urinary mercury, and clinical symptom, the employee who exposed occupationally to mercury can be diagnosed to a certain degree according to the related diagnostic standards. The chelating agent, such as meso-2, 3-dimercapto-succinicacid (DMSA), is used for mercury-lustrating treatment. By reducing the chelating agent dose and supplying necessary trace element, the side effect of chelating treatment is decreased. (authors)

  18. Collection of methods for reliability and safety engineering

    International Nuclear Information System (INIS)

    Fussell, J.B.; Rasmuson, D.M.; Wilson, J.R.; Burdick, G.R.; Zipperer, J.C.

    1976-04-01

    The document presented contains five reports each describing a method of reliability and safety engineering. Report I provides a conceptual framework for the study of component malfunctions during system evaluations. Report II provides methods for locating groups of critical component failures such that all the component failures in a given group can be caused to occur by the occurrence of a single separate event. These groups of component failures are called common cause candidates. Report III provides a method for acquiring and storing system-independent component failure logic information. The information stored is influenced by the concepts presented in Report I and also includes information useful in locating common cause candidates. Report IV puts forth methods for analyzing situations that involve systems which change character in a predetermined time sequence. These phased missions techniques are applicable to the hypothetical ''accident chains'' frequently analyzed for nuclear power plants. Report V presents a unified approach to cause-consequence analysis, a method of analysis useful during risk assessments. This approach, as developed by the Danish Atomic Energy Commission, is modified to reflect the format and symbology conventionally used for other types of analysis of nuclear reactor systems

  19. Method of reliability allocation based on fault tree analysis and fuzzy math in nuclear power plants

    International Nuclear Information System (INIS)

    Chen Zhaobing; Deng Jian; Cao Xuewu

    2005-01-01

    Reliability allocation is a kind of a difficult multi-objective optimization problem. It can not only be applied to determine the reliability characteristic of reactor systems, subsystem and main components but also be performed to improve the design, operation and maintenance of nuclear plants. The fuzzy math known as one of the powerful tools for fuzzy optimization and the fault analysis deemed to be one of the effective methods of reliability analysis can be applied to the reliability allocation model so as to work out the problems of fuzzy characteristic of some factors and subsystem's choice respectively in this paper. Thus we develop a failure rate allocation model on the basis of the fault tree analysis and fuzzy math. For the choice of the reliability constraint factors, we choose the six important ones according to practical need for conducting the reliability allocation. The subsystem selected by the top-level fault tree analysis is to avoid allocating reliability for all the equipment and components including the unnecessary parts. During the reliability process, some factors can be calculated or measured quantitatively while others only can be assessed qualitatively by the expert rating method. So we adopt fuzzy decision and dualistic contrast to realize the reliability allocation with the help of fault tree analysis. Finally the example of the emergency diesel generator's reliability allocation is used to illustrate reliability allocation model and improve this model simple and applicable. (authors)

  20. Recent diagnostic developments on LHD

    International Nuclear Information System (INIS)

    Sudo, S.; Nagayama, Y.; Peterson, B.J.

    2003-01-01

    Standard diagnostics for fundamental plasma parameters and for plasma physics are routinely utilized for daily operation and physics study in the large helical device (LHD) with high reliability. Diagnostics for steady state plasma are intensively developed, especially for T e , n e (YAG laser Thomson, CO 2 laser polarimeter), data acquisition in steady state, heat resistant probes. To clarify the plasma property of the helical structure, 2-D or 3-D diagnostics are intensively developed: Tangential cameras (Fast SX TV, Photon counting CCD, H α TV); Tomography (Tangential SX CCD, Bolometer); Imaging (Bolometer, ECE, Reflectometer). Divertor and edge physics are one of important key issues for steady state operation. Diagnostics for neutral flux (H α array, Zeeman spectroscopy) and n e (Fast scanning probe, Li beam probe, Pulsed radar reflectometer). In addition to these, advanced diagnostics are being intensively developed with national and international collaborations in LHD. (author)

  1. In-service diagnostics of pumping facilities

    International Nuclear Information System (INIS)

    Jaros, I.

    1987-01-01

    The potential is discussed of technical diagnostics in increasing operating reliability of pumping facilities of conventional and nuclear power plants, and in rationalizing the system of their maintenance. Attention is focused on the selection of diagnostic parameters in which the so-called subjective expert methodology is applied, and on the diagnostic system design. At this stage, the construction of the respective facility and the analysis of the failure rate of its individual assemblies should be considered. The selection of diagnostic means directly depends on the selection of diagnostic parameters and is conditional on other factors, such as availability, cost, technical service, and operator's training. Briefly characterized are Czechoslovak standards assessing the mechanical condition of rotary machines from the measurement of the effective value of the rate of their oscillations. (Z.M.)

  2. Methods for estimating the reliability of the RBMK fuel assemblies and elements

    International Nuclear Information System (INIS)

    Klemin, A.I.; Sitkarev, A.G.

    1985-01-01

    Applied non-parametric methods for calculation of point and interval estimations for the basic nomenclature of reliability factors for the RBMK fuel assemblies and elements are described. As the fuel assembly and element reliability factors, the average lifetime is considered at a preset operating time up to unloading due to fuel burnout as well as the average lifetime at the reactor transient operation and at the steady-state fuel reloading mode of reactor operation. The formulae obtained are included into the special standardized engineering documentation

  3. Learning Diagnostic Diagrams in Transport-Based Data-Collection Systems

    DEFF Research Database (Denmark)

    Tran, Vu The; Eklund, Peter; Cook, Chris

    2014-01-01

    Insights about service improvement in a transit network can be gained by studying transit service reliability. In this paper, a general procedure for constructing a transit service reliability diagnostic (Tsrd) diagram based on a Bayesian network is proposed to automatically build a behavioural...

  4. A simple method to combine multiple molecular biomarkers for dichotomous diagnostic classification

    Directory of Open Access Journals (Sweden)

    Amin Manik A

    2006-10-01

    Full Text Available Abstract Background In spite of the recognized diagnostic potential of biomarkers, the quest for squelching noise and wringing in information from a given set of biomarkers continues. Here, we suggest a statistical algorithm that – assuming each molecular biomarker to be a diagnostic test – enriches the diagnostic performance of an optimized set of independent biomarkers employing established statistical techniques. We validated the proposed algorithm using several simulation datasets in addition to four publicly available real datasets that compared i subjects having cancer with those without; ii subjects with two different cancers; iii subjects with two different types of one cancer; and iv subjects with same cancer resulting in differential time to metastasis. Results Our algorithm comprises of three steps: estimating the area under the receiver operating characteristic curve for each biomarker, identifying a subset of biomarkers using linear regression and combining the chosen biomarkers using linear discriminant function analysis. Combining these established statistical methods that are available in most statistical packages, we observed that the diagnostic accuracy of our approach was 100%, 99.94%, 96.67% and 93.92% for the real datasets used in the study. These estimates were comparable to or better than the ones previously reported using alternative methods. In a synthetic dataset, we also observed that all the biomarkers chosen by our algorithm were indeed truly differentially expressed. Conclusion The proposed algorithm can be used for accurate diagnosis in the setting of dichotomous classification of disease states.

  5. Assessment of Electronic Circuits Reliability Using Boolean Truth Table Modeling Method

    International Nuclear Information System (INIS)

    EI-Shanshoury, A.I.

    2011-01-01

    This paper explores the use of Boolean Truth Table modeling Method (BTTM) in the analysis of qualitative data. It is widely used in certain fields especially in the fields of electrical and electronic engineering. Our work focuses on the evaluation of power supply circuit reliability using (BTTM) which involves systematic attempts to falsify and identify hypotheses on the basis of truth tables constructed from qualitative data. Reliability parameters such as the system's failure rates for the power supply case study are estimated. All possible state combinations (operating and failed states) of the major components in the circuit were listed and their effects on overall system were studied

  6. Trichinella diagnostics and control: Mandatory and best practices for ensuring food safety

    DEFF Research Database (Denmark)

    Gajadhar, A. A.; Pozio, E.; Gamble, H. R.

    2009-01-01

    Because of its role in human disease, there are increasing global requirements for reliable diagnostic and control methods for Trichinella in food animals to ensure meat safety and to facilitate trade. Consequently, there is a need for standardization of methods, programs, and best practices used...... in various porcine and equine pre- and post-slaughter programs, including farm or herd certification programs is also discussed. A brief review of the effectiveness of meat processing methods, such as freezing, cooking and preserving is provided. The importance of proper quality assurance and its application...

  7. An attempt to use FMEA method for an approximate reliability assessment of machinery

    Directory of Open Access Journals (Sweden)

    Przystupa Krzysztof

    2017-01-01

    Full Text Available The paper presents a modified FMEA (Failure Mode and Effect Analysis method to assess reliability of the components that make up a wrench type 2145: MAX Impactol TM Driver Ingersoll Rand Company. This case concerns the analysis of reliability in conditions, when full service data is not known. The aim of the study is to determine the weakest element in the design of the tool.

  8. Identification of reliable gridded reference data for statistical downscaling methods in Alberta

    Science.gov (United States)

    Eum, H. I.; Gupta, A.

    2017-12-01

    Climate models provide essential information to assess impacts of climate change at regional and global scales. However, statistical downscaling methods have been applied to prepare climate model data for various applications such as hydrologic and ecologic modelling at a watershed scale. As the reliability and (spatial and temporal) resolution of statistically downscaled climate data mainly depend on a reference data, identifying the most reliable reference data is crucial for statistical downscaling. A growing number of gridded climate products are available for key climate variables which are main input data to regional modelling systems. However, inconsistencies in these climate products, for example, different combinations of climate variables, varying data domains and data lengths and data accuracy varying with physiographic characteristics of the landscape, have caused significant challenges in selecting the most suitable reference climate data for various environmental studies and modelling. Employing various observation-based daily gridded climate products available in public domain, i.e. thin plate spline regression products (ANUSPLIN and TPS), inverse distance method (Alberta Townships), and numerical climate model (North American Regional Reanalysis) and an optimum interpolation technique (Canadian Precipitation Analysis), this study evaluates the accuracy of the climate products at each grid point by comparing with the Adjusted and Homogenized Canadian Climate Data (AHCCD) observations for precipitation, minimum and maximum temperature over the province of Alberta. Based on the performance of climate products at AHCCD stations, we ranked the reliability of these publically available climate products corresponding to the elevations of stations discretized into several classes. According to the rank of climate products for each elevation class, we identified the most reliable climate products based on the elevation of target points. A web-based system

  9. [A reliability growth assessment method and its application in the development of equipment in space cabin].

    Science.gov (United States)

    Chen, J D; Sun, H L

    1999-04-01

    Objective. To assess and predict reliability of an equipment dynamically by making full use of various test informations in the development of products. Method. A new reliability growth assessment method based on army material system analysis activity (AMSAA) model was developed. The method is composed of the AMSAA model and test data conversion technology. Result. The assessment and prediction results of a space-borne equipment conform to its expectations. Conclusion. It is suggested that this method should be further researched and popularized.

  10. On improving of efficiency of plasma diagnostics with the help of computer

    International Nuclear Information System (INIS)

    Temko, S.W.; Temko, K.W.; Kuz'min, S.K.

    1994-01-01

    The cloud of weakly ionized plasma contaminated by impurities is considered. Impurities are the large-size particles, resulting under influence of adhesion and coagulation. Impurities cause decrease conduction and increase of radiation energy losses. To precipitate impurities one can use ultrasonic coagulation. However, under the acting ultrasonics the turbulence arises and instabilities, disturbing the plasma state, can develop. To stabilize plasma state and to deposit impurities on the walls of gas-discharge camera one needs both the data on diagnostics and the results of calculations as well as the system of situation adaptive controlling. The situations are time-dependent plasma states. The control system is formed from the distributed microprocessors network and from controlling computer. Microprocessors are installed on diagnostic installations, on energy sources and on ultrasonic signals supplies. To improve reliability and refusal-stability of the control system an apparatus, program and time excessivenesses are used. An effective methods of diagnostics can be SHF-methods and laser diagnostics. To find optical calculating data the authors apply statistical thermodynamics of spatial clusters, which was proposed by the authors earlier. Computer compares under the given program the diagnostic data with the results of calculations and produces control responses both on power sources and on generators of ultrasonic signals

  11. Reliable B cell epitope predictions: impacts of method development and improved benchmarking

    DEFF Research Database (Denmark)

    Kringelum, Jens Vindahl; Lundegaard, Claus; Lund, Ole

    2012-01-01

    biomedical applications such as; rational vaccine design, development of disease diagnostics and immunotherapeutics. However, experimental mapping of epitopes is resource intensive making in silico methods an appealing complementary approach. To date, the reported performance of methods for in silico mapping...... evaluation data set improved from 0.712 to 0.727. Our results thus demonstrate that given proper benchmark definitions, B-cell epitope prediction methods achieve highly significant predictive performances suggesting these tools to be a powerful asset in rational epitope discovery. The updated version...

  12. Reliability-Based Topology Optimization Using Stochastic Response Surface Method with Sparse Grid Design

    Directory of Open Access Journals (Sweden)

    Qinghai Zhao

    2015-01-01

    Full Text Available A mathematical framework is developed which integrates the reliability concept into topology optimization to solve reliability-based topology optimization (RBTO problems under uncertainty. Two typical methodologies have been presented and implemented, including the performance measure approach (PMA and the sequential optimization and reliability assessment (SORA. To enhance the computational efficiency of reliability analysis, stochastic response surface method (SRSM is applied to approximate the true limit state function with respect to the normalized random variables, combined with the reasonable design of experiments generated by sparse grid design, which was proven to be an effective and special discretization technique. The uncertainties such as material property and external loads are considered on three numerical examples: a cantilever beam, a loaded knee structure, and a heat conduction problem. Monte-Carlo simulations are also performed to verify the accuracy of the failure probabilities computed by the proposed approach. Based on the results, it is demonstrated that application of SRSM with SGD can produce an efficient reliability analysis in RBTO which enables a more reliable design than that obtained by DTO. It is also found that, under identical accuracy, SORA is superior to PMA in view of computational efficiency.

  13. Reliability and Sensitivity Analysis for Laminated Composite Plate Using Response Surface Method

    International Nuclear Information System (INIS)

    Lee, Seokje; Kim, Ingul; Jang, Moonho; Kim, Jaeki; Moon, Jungwon

    2013-01-01

    Advanced fiber-reinforced laminated composites are widely used in various fields of engineering to reduce weight. The material property of each ply is well known; specifically, it is known that ply is less reliable than metallic materials and very sensitive to the loading direction. Therefore, it is important to consider this uncertainty in the design of laminated composites. In this study, reliability analysis is conducted using Callosum and Meatball interactions for a laminated composite plate for the case in which the tip deflection is the design requirement and the material property is a random variable. Furthermore, the efficiency and accuracy of the approximation method is identified, and a probabilistic sensitivity analysis is conducted. As a result, we can prove the applicability of the advanced design method for the stabilizer of an underwater vehicle

  14. Reliability and Sensitivity Analysis for Laminated Composite Plate Using Response Surface Method

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seokje; Kim, Ingul [Chungnam National Univ., Daejeon (Korea, Republic of); Jang, Moonho; Kim, Jaeki; Moon, Jungwon [LIG Nex1, Yongin (Korea, Republic of)

    2013-04-15

    Advanced fiber-reinforced laminated composites are widely used in various fields of engineering to reduce weight. The material property of each ply is well known; specifically, it is known that ply is less reliable than metallic materials and very sensitive to the loading direction. Therefore, it is important to consider this uncertainty in the design of laminated composites. In this study, reliability analysis is conducted using Callosum and Meatball interactions for a laminated composite plate for the case in which the tip deflection is the design requirement and the material property is a random variable. Furthermore, the efficiency and accuracy of the approximation method is identified, and a probabilistic sensitivity analysis is conducted. As a result, we can prove the applicability of the advanced design method for the stabilizer of an underwater vehicle.

  15. Analyzing the reliability of shuffle-exchange networks using reliability block diagrams

    International Nuclear Information System (INIS)

    Bistouni, Fathollah; Jahanshahi, Mohsen

    2014-01-01

    Supercomputers and multi-processor systems are comprised of thousands of processors that need to communicate in an efficient way. One reasonable solution would be the utilization of multistage interconnection networks (MINs), where the challenge is to analyze the reliability of such networks. One of the methods to increase the reliability and fault-tolerance of the MINs is use of various switching stages. Therefore, recently, the reliability of one of the most common MINs namely shuffle-exchange network (SEN) has been evaluated through the investigation on the impact of increasing the number of switching stage. Also, it is concluded that the reliability of SEN with one additional stage (SEN+) is better than SEN or SEN with two additional stages (SEN+2), even so, the reliability of SEN is better compared to SEN with two additional stages (SEN+2). Here we re-evaluate the reliability of these networks where the results of the terminal, broadcast, and network reliability analysis demonstrate that SEN+ and SEN+2 continuously outperform SEN and are very alike in terms of reliability. - Highlights: • The impact of increasing the number of stages on reliability of MINs is investigated. • The RBD method as an accurate method is used for the reliability analysis of MINs. • Complex series–parallel RBDs are used to determine the reliability of the MINs. • All measures of the reliability (i.e. terminal, broadcast, and network reliability) are analyzed. • All reliability equations will be calculated for different size N×N

  16. Reliable methods for computer simulation error control and a posteriori estimates

    CERN Document Server

    Neittaanmäki, P

    2004-01-01

    Recent decades have seen a very rapid success in developing numerical methods based on explicit control over approximation errors. It may be said that nowadays a new direction is forming in numerical analysis, the main goal of which is to develop methods ofreliable computations. In general, a reliable numerical method must solve two basic problems: (a) generate a sequence of approximations that converges to a solution and (b) verify the accuracy of these approximations. A computer code for such a method must consist of two respective blocks: solver and checker.In this book, we are chie

  17. Diagnostics for plasma control on DEMO: challenges of implementation

    NARCIS (Netherlands)

    Donne, A. J. H.; Costley, A. E.; Morris, A. W.

    2012-01-01

    As a test fusion power plant, DEMO will have to demonstrate reliability and very long pulse/steady-state operation, which calls for unprecedented robustness and reliability of all diagnostic systems (also requiring adequate redundancy). But DEMO will have higher levels of neutron and gamma fluxes,

  18. The Increase of Operational Safety of Ships by Improving Diagnostic Methods for Marine Diesel Engine

    Directory of Open Access Journals (Sweden)

    Kazimierz Witkowski

    2017-06-01

    Full Text Available This article shows the importance of the diagnostic improvement methods of marine engines to boost the economy and safety of operation of marine cargo ships. The need to implement effective diagnostic methods is justified by presenting statistical data of marine diesel engines failure and the cost of their operation. Based on the own research has been proven, for the chosen example, that indicator diagrams and analysis of indicated parameters have limited utility in the diagnosis of damages of marine engine, although this is a method commonly used in operational practice. To achieve greater diagnostic effectiveness, when, based on indicator diagrams, are calculated and then the characteristics of heat release is analyzed - net of heat release characteristics and the intensity of the heat release, it was demonstrated. This procedure is particularly effective in the diagnosis of damage of injection system components marine diesel engine.

  19. A diagnostic test for apraxia in stroke patients: internal consistency and diagnostic value.

    NARCIS (Netherlands)

    Heugten, C.M. van; Dekker, J.; Deelman, B.G.; Stehmann-Saris, F.C.; Kinebanian, A.

    1999-01-01

    The internal consistency and the diagnostic value of a test for apraxia in patients having had a stroke are presented. Results indicate that the items of the test form a strong and consistent scale: Cronbach's alpha as well as the results of a Mokken scale analysis present good reliability and good

  20. INTEGRATED APPLICATION OF OPTICAL DIAGNOSTIC METHODS IN ULCERATIVE COLITIS

    Directory of Open Access Journals (Sweden)

    E. V. Velikanov

    2013-01-01

    Full Text Available Abstract. Our results suggest that the combined use of optical coherent tomography (OCT and fluorescence diagnosis helps to refine the nature and boundaries of the pathological process in the tissue of the colon in ulcerative colitis. Studies have shown that an integrated optical diagnostics allows us to differentiate lesions respectively to histology and to decide on the need for biopsy and venue. This method is most appropriate in cases difficult for diagnosis. 

  1. How to Map Theory: Reliable Methods Are Fruitless Without Rigorous Theory.

    Science.gov (United States)

    Gray, Kurt

    2017-09-01

    Good science requires both reliable methods and rigorous theory. Theory allows us to build a unified structure of knowledge, to connect the dots of individual studies and reveal the bigger picture. Some have criticized the proliferation of pet "Theories," but generic "theory" is essential to healthy science, because questions of theory are ultimately those of validity. Although reliable methods and rigorous theory are synergistic, Action Identification suggests psychological tension between them: The more we focus on methodological details, the less we notice the broader connections. Therefore, psychology needs to supplement training in methods (how to design studies and analyze data) with training in theory (how to connect studies and synthesize ideas). This article provides a technique for visually outlining theory: theory mapping. Theory mapping contains five elements, which are illustrated with moral judgment and with cars. Also included are 15 additional theory maps provided by experts in emotion, culture, priming, power, stress, ideology, morality, marketing, decision-making, and more (see all at theorymaps.org ). Theory mapping provides both precision and synthesis, which helps to resolve arguments, prevent redundancies, assess the theoretical contribution of papers, and evaluate the likelihood of surprising effects.

  2. Inter- and intra- observer reliability of risk assessment of repetitive work without an explicit method.

    Science.gov (United States)

    Eliasson, Kristina; Palm, Peter; Nyman, Teresia; Forsman, Mikael

    2017-07-01

    A common way to conduct practical risk assessments is to observe a job and report the observed long term risks for musculoskeletal disorders. The aim of this study was to evaluate the inter- and intra-observer reliability of ergonomists' risk assessments without the support of an explicit risk assessment method. Twenty-one experienced ergonomists assessed the risk level (low, moderate, high risk) of eight upper body regions, as well as the global risk of 10 video recorded work tasks. Intra-observer reliability was assessed by having nine of the ergonomists repeat the procedure at least three weeks after the first assessment. The ergonomists made their risk assessment based on his/her experience and knowledge. The statistical parameters of reliability included agreement in %, kappa, linearly weighted kappa, intraclass correlation and Kendall's coefficient of concordance. The average inter-observer agreement of the global risk was 53% and the corresponding weighted kappa (K w ) was 0.32, indicating fair reliability. The intra-observer agreement was 61% and 0.41 (K w ). This study indicates that risk assessments of the upper body, without the use of an explicit observational method, have non-acceptable reliability. It is therefore recommended to use systematic risk assessment methods to a higher degree. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. DEPEND-HRA-A method for consideration of dependency in human reliability analysis

    International Nuclear Information System (INIS)

    Cepin, Marko

    2008-01-01

    A consideration of dependencies between human actions is an important issue within the human reliability analysis. A method was developed, which integrates the features of existing methods and the experience from a full scope plant simulator. The method is used on real plant-specific human reliability analysis as a part of the probabilistic safety assessment of a nuclear power plant. The method distinguishes dependency for pre-initiator events from dependency for initiator and post-initiator events. The method identifies dependencies based on scenarios, where consecutive human actions are modeled, and based on a list of minimal cut sets, which is obtained by running the minimal cut set analysis considering high values of human error probabilities in the evaluation. A large example study, which consisted of a large number of human failure events, demonstrated the applicability of the method. Comparative analyses that were performed show that both selection of dependency method and selection of dependency levels within the method largely impact the results of probabilistic safety assessment. If the core damage frequency is not impacted much, the listings of important basic events in terms of risk increase and risk decrease factors may change considerably. More efforts are needed on the subject, which will prepare the background for more detailed guidelines, which will remove the subjectivity from the evaluations as much as it is possible

  4. The six-item Clock Drawing Test – reliability and validity in mild Alzheimer’s disease

    DEFF Research Database (Denmark)

    Jørgensen, Kasper; Kristensen, Maria K; Waldemar, Gunhild

    2015-01-01

    This study presents a reliable, short and practical version of the Clock Drawing Test (CDT) for clinical use and examines its diagnostic accuracy in mild Alzheimer's disease versus elderly nonpatients. Clock drawings from 231 participants were scored independently by four clinical neuropsychologi......This study presents a reliable, short and practical version of the Clock Drawing Test (CDT) for clinical use and examines its diagnostic accuracy in mild Alzheimer's disease versus elderly nonpatients. Clock drawings from 231 participants were scored independently by four clinical...... neuropsychologists blind to diagnostic classification. The interrater agreement of individual scoring criteria was analyzed and items with poor or moderate reliability were excluded. The classification accuracy of the resulting scoring system - the six-item CDT - was examined. We explored the effect of further...

  5. Isothermal multiple displacement amplification: a methodical approach enhancing molecular routine diagnostics of microcarcinomas and small biopsies.

    Science.gov (United States)

    Mairinger, Fabian D; Walter, Robert Fh; Vollbrecht, Claudia; Hager, Thomas; Worm, Karl; Ting, Saskia; Wohlschläger, Jeremias; Zarogoulidis, Paul; Zarogoulidis, Konstantinos; Schmid, Kurt W

    2014-01-01

    Isothermal multiple displacement amplification (IMDA) can be a powerful tool in molecular routine diagnostics for homogeneous and sequence-independent whole-genome amplification of notably small tumor samples, eg, microcarcinomas and biopsies containing a small amount of tumor. Currently, this method is not well established in pathology laboratories. We designed a study to confirm the feasibility and convenience of this method for routine diagnostics with formalin-fixed, paraffin-embedded samples prepared by laser-capture microdissection. A total of 250 μg DNA (concentration 5 μg/μL) was generated by amplification over a period of 8 hours with a material input of approximately 25 cells, approximately equivalent to 175 pg of genomic DNA. In the generated DNA, a representation of all chromosomes could be shown and the presence of elected genes relevant for diagnosis in clinical samples could be proven. Mutational analysis of clinical samples could be performed without any difficulty and showed concordance with earlier diagnostic findings. We established the feasibility and convenience of IMDA for routine diagnostics. We also showed that small amounts of DNA, which were not analyzable with current molecular methods, could be sufficient for a wide field of applications in molecular routine diagnostics when they are preamplified with IMDA.

  6. Battery Test Facility- Electrochemical Analysis and Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrochemical Analysis and Diagnostics Laboratory (EADL) provides battery developers with reliable, independent, and unbiased performance evaluations of their...

  7. Review of Physicochemical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers

    Directory of Open Access Journals (Sweden)

    Janvier Sylvestre N’cho

    2016-05-01

    Full Text Available A power transformer outage has a dramatic financial consequence not only for electric power systems utilities but also for interconnected customers. The service reliability of this important asset largely depends upon the condition of the oil-paper insulation. Therefore, by keeping the qualities of oil-paper insulation system in pristine condition, the maintenance planners can reduce the decline rate of internal faults. Accurate diagnostic methods for analyzing the condition of transformers are therefore essential. Currently, there are various electrical and physicochemical diagnostic techniques available for insulation condition monitoring of power transformers. This paper is aimed at the description, analysis and interpretation of modern physicochemical diagnostics techniques for assessing insulation condition in aged transformers. Since fields and laboratory experiences have shown that transformer oil contains about 70% of diagnostic information, the physicochemical analyses of oil samples can therefore be extremely useful in monitoring the condition of power transformers.

  8. Development of reliability centered maintenance methods and tools

    International Nuclear Information System (INIS)

    Jacquot, J.P.; Dubreuil-Chambardel, A.; Lannoy, A.; Monnier, B.

    1992-12-01

    This paper recalls the development of the RCM (Reliability Centered Maintenance) approach in the nuclear industry and describes the trial study implemented by EDF in the context of the OMF (RCM) Project. The approach developed is currently being applied to about thirty systems (Industrial Project). On a parallel, R and D efforts are being maintained to improve the selectivity of the analysis methods. These methods use Probabilistic Safety Study models, thereby guaranteeing better selectivity in the identification of safety critical elements and enhancing consistency between Maintenance and Safety studies. They also offer more detailed analysis of operation feedback, invoking for example Bayes' methods combining expert judgement and feedback data. Finally, they propose a functional and material representation of the plant. This dual representation describes both the functions assured by maintenance provisions and the material elements required for their implementation. In the final chapter, the targets of the future OMF workstation are summarized and the latter's insertion in the EDF information system is briefly described. (authors). 5 figs., 2 tabs., 7 refs

  9. Evaluation of the reliability of Levine method of wound swab for ...

    African Journals Online (AJOL)

    The aim of this paper is to evaluate the reliability of Levine swab in accurate identification of microorganisms present in a wound and identify the necessity for further studies in this regard. Methods: A semi structured questionnaire was administered and physical examination was performed on patients with chronic wounds ...

  10. GNSS Single Frequency, Single Epoch Reliable Attitude Determination Method with Baseline Vector Constraint

    Directory of Open Access Journals (Sweden)

    Ang Gong

    2015-12-01

    Full Text Available For Global Navigation Satellite System (GNSS single frequency, single epoch attitude determination, this paper proposes a new reliable method with baseline vector constraint. First, prior knowledge of baseline length, heading, and pitch obtained from other navigation equipment or sensors are used to reconstruct objective function rigorously. Then, searching strategy is improved. It substitutes gradually Enlarged ellipsoidal search space for non-ellipsoidal search space to ensure correct ambiguity candidates are within it and make the searching process directly be carried out by least squares ambiguity decorrelation algorithm (LAMBDA method. For all vector candidates, some ones are further eliminated by derived approximate inequality, which accelerates the searching process. Experimental results show that compared to traditional method with only baseline length constraint, this new method can utilize a priori baseline three-dimensional knowledge to fix ambiguity reliably and achieve a high success rate. Experimental tests also verify it is not very sensitive to baseline vector error and can perform robustly when angular error is not great.

  11. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems

    Science.gov (United States)

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Background Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA”, which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). Methods We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. Results According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%” on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Conclusion Such a smart, economical, non-invasive, rapid

  12. Aggressive periodontitis: case definition and diagnostic criteria.

    Science.gov (United States)

    Albandar, Jasim M

    2014-06-01

    Aggressive periodontitis is a destructive disease characterized by the following: the involvement of multiple teeth with a distinctive pattern of periodontal tissue loss; a high rate of disease progression; an early age of onset; and the absence of systemic diseases. In some patients periodontal tissue loss may commence before puberty, whereas in most patients the age of onset is during or somewhat after the circumpubertal period. Besides infection with specific microorganisms, a host predisposition seems to play a key role in the pathogenesis of aggressive periodontitis, as evidenced by the familial aggregation of the disease. In this article we review the historical background of the diagnostic criteria of aggressive periodontitis, present a contemporary case definition and describe the clinical parameters of the disease. At present, the diagnosis of aggressive periodontitis is achieved using case history, clinical examination and radiographic evaluation. The data gathered using these methods are prone to relatively high measurement errors. Besides, this diagnostic approach measures past disease history and may not reliably measure existing disease activity or accurately predict future tissue loss. A diagnosis is often made years after the onset of the disease, partly because current assessment methods detect established disease more readily and reliably than they detect incipient or initial lesions where the tissue loss is minimal and usually below the detection threshold of present examination methods. Future advancements in understanding the pathogenesis of this disease may contribute to an earlier diagnosis. Insofar, future case definitions may involve the identification of key etiologic and risk factors, combined with high-precision methodologies that enable the early detection of initial lesions. This may significantly enhance the predictive value of these tests and detect cases of aggressive periodontitis before significant tissue loss develops. © 2014

  13. A Novel Diagnostic Aid for Detection of Intra-Abdominal Adhesions to the Anterior Abdominal Wall Using Dynamic Magnetic Resonance Imaging

    NARCIS (Netherlands)

    Randall, D.; Fenner, J.; Gillott, R.; Broek, R.P.G ten; Strik, C.; Spencer, P.; Bardhan, K.D.

    2016-01-01

    Introduction. Abdominal adhesions can cause serious morbidity and complicate subsequent operations. Their diagnosis is often one of exclusion due to a lack of a reliable, non-invasive diagnostic technique. Development and testing of a candidate technique are described below. Method. During

  14. Rolling element bearings diagnostics using the Symbolic Aggregate approXimation

    Science.gov (United States)

    Georgoulas, George; Karvelis, Petros; Loutas, Theodoros; Stylios, Chrysostomos D.

    2015-08-01

    Rolling element bearings are a very critical component in various engineering assets. Therefore it is of paramount importance the detection of possible faults, especially at an early stage, that may lead to unexpected interruptions of the production or worse, to severe accidents. This research work introduces a novel, in the field of bearing fault detection, method for the extraction of diagnostic representations of vibration recordings using the Symbolic Aggregate approXimation (SAX) framework and the related intelligent icons representation. SAX essentially transforms the original real valued time-series into a discrete one, which is then represented by a simple histogram form summarizing the occurrence of the chosen symbols/words. Vibration signals from healthy bearings and bearings with three different fault locations and with three different severity levels, as well as loading conditions, are analyzed. Considering the diagnostic problem as a classification one, the analyzed vibration signals and the resulting feature vectors feed simple classifiers achieving remarkably high classification accuracies. Moreover a sliding window scheme combined with a simple majority voting filter further increases the reliability and robustness of the diagnostic method. The results encourage the potential use of the proposed methodology for the diagnosis of bearing faults.

  15. Features of an advanced human reliability analysis method, AGAPE-ET

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Whan; Jung, Won Dea; Park, Jin Kyun [Korea Atomic Energy Research Institute, Taejeon (Korea, Republic of)

    2005-11-15

    This paper presents the main features of an advanced human reliability analysis (HRA) method, AGAPE-ET. It has the capabilities to deal with the diagnosis failures and the errors of commission (EOC), which have not been normally treated in the conventional HRAs. For the analysis of the potential for diagnosis failures, an analysis framework, which is called the misdiagnosis tree analysis (MDTA), and a taxonomy of the misdiagnosis causes with appropriate quantification schemes are provided. For the identification of the EOC events from the misdiagnosis, some procedural guidance is given. An example of the application of the method is also provided.

  16. Features of an advanced human reliability analysis method, AGAPE-ET

    International Nuclear Information System (INIS)

    Kim, Jae Whan; Jung, Won Dea; Park, Jin Kyun

    2005-01-01

    This paper presents the main features of an advanced human reliability analysis (HRA) method, AGAPE-ET. It has the capabilities to deal with the diagnosis failures and the errors of commission (EOC), which have not been normally treated in the conventional HRAs. For the analysis of the potential for diagnosis failures, an analysis framework, which is called the misdiagnosis tree analysis (MDTA), and a taxonomy of the misdiagnosis causes with appropriate quantification schemes are provided. For the identification of the EOC events from the misdiagnosis, some procedural guidance is given. An example of the application of the method is also provided

  17. Assessment of Advanced Life Support competence when combining different test methods--reliability and validity

    DEFF Research Database (Denmark)

    Ringsted, C; Lippert, F; Hesselfeldt, R

    2007-01-01

    Cardiac Arrest Simulation Test (CASTest) scenarios for the assessments according to guidelines 2005. AIMS: To analyse the reliability and validity of the individual sub-tests provided by ERC and to find a combination of MCQ and CASTest that provides a reliable and valid single effect measure of ALS...... that possessed high reliability, equality of test sets, and ability to discriminate between the two groups of supposedly different ALS competence. CONCLUSIONS: ERC sub-tests of ALS competence possess sufficient reliability and validity. A combined ALS score with equal weighting of one MCQ and one CASTest can...... competence. METHODS: Two groups of participants were included in this randomised, controlled experimental study: a group of newly graduated doctors, who had not taken the ALS course (N=17) and a group of students, who had passed the ALS course 9 months before the study (N=16). Reliability in terms of inter...

  18. Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes

    Directory of Open Access Journals (Sweden)

    Beng Kwang Ng

    2013-01-01

    Full Text Available Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standard diagnostic methods for rupture of membranes and placental alpha microglobulin-1 immunoassay. The actual rupture of membranes was diagnosed on review of the medical records after delivery (absence of membrane or a positive pad chart. Main Outcome Measures. Placental alpha microglobulin-1 immunoassay and standard diagnostic methods for diagnosis of rupture of membrane. Results. A total of 211 patients were recruited. At initial presentation, 187 patients (88.6% had ruptured membranes, while 24 patients (11.4% had intact membranes. Placental alpha microglobulin-1 immunoassay confirmed rupture of membranes at initial presentation with a sensitivity of 95.7% (179 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (179 of 179, and negative predictive value of 75.0% (24 of 32. By comparison, the conventional standard diagnostic methods had a sensitivity of 78.1% (146 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (146 of 146, and negative predictive value of 36.9% (24 of 65 in diagnosing rupture of membrane. Conclusion. Placental alpha-microglobulin-1 immunoassay is a rapid and accurate method for confirming the diagnosis of rupture of membrane. It was superior to conventional standard diagnostic methods (pooling, nitrazine, and ferning, the nitrazine test alone or fern test alone.

  19. LOGICAL CONDITIONS ANALYSIS METHOD FOR DIAGNOSTIC TEST RESULTS DECODING APPLIED TO COMPETENCE ELEMENTS PROFICIENCY

    Directory of Open Access Journals (Sweden)

    V. I. Freyman

    2015-11-01

    Full Text Available Subject of Research.Representation features of education results for competence-based educational programs are analyzed. Solution importance of decoding and proficiency estimation for elements and components of discipline parts of competences is shown. The purpose and objectives of research are formulated. Methods. The paper deals with methods of mathematical logic, Boolean algebra, and parametrical analysis of complex diagnostic test results, that controls proficiency of some discipline competence elements. Results. The method of logical conditions analysis is created. It will give the possibility to formulate logical conditions for proficiency determination of each discipline competence element, controlled by complex diagnostic test. Normalized test result is divided into noncrossing zones; a logical condition about controlled elements proficiency is formulated for each of them. Summarized characteristics for test result zones are imposed. An example of logical conditions forming for diagnostic test with preset features is provided. Practical Relevance. The proposed method of logical conditions analysis is applied in the decoding algorithm of proficiency test diagnosis for discipline competence elements. It will give the possibility to automate the search procedure for elements with insufficient proficiency, and is also usable for estimation of education results of a discipline or a component of competence-based educational program.

  20. Overall comparison of subpicosecond electron beam diagnostics by the polychromator, the interferometer and the femtosecond streak camera

    CERN Document Server

    Watanabe, T; Yoshimatsu, T; Sasaki, S; Sugiyama, Y; Ishi, K; Shibata, Y; Kondo, Y; Yoshii, K; Ueda, T; Uesaka, M

    2002-01-01

    Measurements of longitudinal bunch length of subpicosecond and picosecond electron beams have been performed by three methods with three radiation sources at the 35 MeV S-band twin liner accelerators at Nuclear Engineering Research Laboratory, University of Tokyo. The methods we adopt are the femtosecond streak camera with a nondispersive reflective optics, the coherent transition radiation (CTR) Michelson interferometer and the 10 ch polychromator that detects the spectrum of CTR and coherent diffraction radiation (CDR). The measurements by the two CTR methods were independently done with the streak camera and their results were consistent with one another. As a result, the reliability of the polychromator for the diagnostics of less than picosecond electron bunch and the usefulness of the diagnostics for the single shot measurement were verified. Furthermore, perfect nondestructive diagnostics for subpicosecond bunches was performed utilizing CDR interferometry. Then the good agreement between CDR interfero...

  1. A Fast Optimization Method for Reliability and Performance of Cloud Services Composition Application

    Directory of Open Access Journals (Sweden)

    Zhao Wu

    2013-01-01

    Full Text Available At present the cloud computing is one of the newest trends of distributed computation, which is propelling another important revolution of software industry. The cloud services composition is one of the key techniques in software development. The optimization for reliability and performance of cloud services composition application, which is a typical stochastic optimization problem, is confronted with severe challenges due to its randomness and long transaction, as well as the characteristics of the cloud computing resources such as openness and dynamic. The traditional reliability and performance optimization techniques, for example, Markov model and state space analysis and so forth, have some defects such as being too time consuming and easy to cause state space explosion and unsatisfied the assumptions of component execution independence. To overcome these defects, we propose a fast optimization method for reliability and performance of cloud services composition application based on universal generating function and genetic algorithm in this paper. At first, a reliability and performance model for cloud service composition application based on the multiple state system theory is presented. Then the reliability and performance definition based on universal generating function is proposed. Based on this, a fast reliability and performance optimization algorithm is presented. In the end, the illustrative examples are given.

  2. Coupling finite elements and reliability methods - application to safety evaluation of pressurized water reactor vessels

    International Nuclear Information System (INIS)

    Pitner, P.; Venturini, V.

    1995-02-01

    When reliability studies are extended form deterministic calculations in mechanics, it is necessary to take into account input parameters variabilities which are linked to the different sources of uncertainty. Integrals must then be calculated to evaluate the failure risk. This can be performed either by simulation methods, or by approximations ones (FORM/SORM). Model in mechanics often require to perform calculation codes. These ones must then be coupled with the reliability calculations. Theses codes can involve large calculation times when they are invoked numerous times during simulations sequences or in complex iterative procedures. Response surface method gives an approximation of the real response from a reduced number of points for which the finite element code is run. Thus, when it is combined with FORM/SORM methods, a coupling can be carried out which gives results in a reasonable calculation time. An application of response surface method to mechanics reliability coupling for a mechanical model which calls for a finite element code is presented. It corresponds to a probabilistic fracture mechanics study of a pressurized water reactor vessel. (authors). 5 refs., 3 figs

  3. Development of real time diagnostics and feedback algorithms for JET in view of the next step

    Energy Technology Data Exchange (ETDEWEB)

    Murari, A.; Barana, O. [Consorzio RFX Associazione EURATOM ENEA per la Fusione, Corso Stati Uniti 4, Padua (Italy); Felton, R.; Zabeo, L.; Piccolo, F.; Sartori, F. [Euratom/UKAEA Fusion Assoc., Culham Science Centre, Abingdon, Oxon (United Kingdom); Joffrin, E.; Mazon, D.; Laborde, L.; Moreau, D. [Association EURATOM-CEA, CEA Cadarache, 13 - Saint-Paul-lez-Durance (France); Albanese, R. [Assoc. Euratom-ENEA-CREATE, Univ. Mediterranea RC (Italy); Arena, P.; Bruno, M. [Assoc. Euratom-ENEA-CREATE, Univ.di Catania (Italy); Ambrosino, G.; Ariola, M. [Assoc. Euratom-ENEA-CREATE, Univ. Napoli Federico Napoli (Italy); Crisanti, F. [Associazone EURATOM ENEA sulla Fusione, C.R. Frascati (Italy); Luna, E. de la; Sanchez, J. [Associacion EURATOM CIEMAT para Fusion, Madrid (Spain)

    2004-07-01

    Real time control of many plasma parameters will be an essential aspect in the development of reliable high performance operation of Next Step Tokamaks. The main prerequisites for any feedback scheme are the precise real-time determination of the quantities to be controlled, requiring top quality and highly reliable diagnostics, and the availability of robust control algorithms. A new set of real time diagnostics was recently implemented on JET to prove the feasibility of determining, with high accuracy and time resolution, the most important plasma quantities. With regard to feedback algorithms, new model-based controllers were developed to allow a more robust control of several plasma parameters. Both diagnostics and algorithms were successfully used in several experiments, ranging from H-mode plasmas to configuration with ITBs (internal thermal barriers). Since elaboration of computationally heavy measurements is often required, significant attention was devoted to non-algorithmic methods like Digital or Cellular Neural/Nonlinear Networks. The real time hardware and software adopted architectures are also described with particular attention to their relevance to ITER. (authors)

  4. Development of real time diagnostics and feedback algorithms for JET in view of the next step

    International Nuclear Information System (INIS)

    Murari, A.; Felton, R.; Zabeo, L.; Piccolo, F.; Sartori, F.; Murari, A.; Barana, O.; Albanese, R.; Joffrin, E.; Mazon, D.; Laborde, L.; Moreau, D.; Arena, P.; Bruno, M.; Ambrosino, G.; Ariola, M.; Crisanti, F.; Luna, E. de la; Sanchez, J.

    2004-01-01

    Real time control of many plasma parameters will be an essential aspect in the development of reliable high performance operation of Next Step Tokamaks. The main prerequisites for any feedback scheme are the precise real-time determination of the quantities to be controlled, requiring top quality and highly reliable diagnostics, and the availability of robust control algorithms. A new set of real time diagnostics was recently implemented on JET to prove the feasibility of determining, with high accuracy and time resolution, the most important plasma quantities. With regard to feedback algorithms, new model-based controllers were developed to allow a more robust control of several plasma parameters. Both diagnostics and algorithms were successfully used in several experiments, ranging from H-mode plasmas to configuration with internal transport barriers. Since elaboration of computationally heavy measurements is often required, significant attention was devoted to non-algorithmic methods like Digital or Cellular Neural/Nonlinear Networks. The real time hardware and software adopted architectures are also described with particular attention to their relevance to ITER. (authors)

  5. Development of real time diagnostics and feedback algorithms for JET in view of the next step

    International Nuclear Information System (INIS)

    Murari, A.; Barana, O.; Murari, A.; Felton, R.; Zabeo, L.; Piccolo, F.; Sartori, F.; Joffrin, E.; Mazon, D.; Laborde, L.; Moreau, D.; Albanese, R.; Arena, P.; Bruno, M.; Ambrosino, G.; Ariola, M.; Crisanti, F.; Luna, E. de la; Sanchez, J.

    2004-01-01

    Real time control of many plasma parameters will be an essential aspect in the development of reliable high performance operation of Next Step Tokamaks. The main prerequisites for any feedback scheme are the precise real-time determination of the quantities to be controlled, requiring top quality and highly reliable diagnostics, and the availability of robust control algorithms. A new set of real time diagnostics was recently implemented on JET to prove the feasibility of determining, with high accuracy and time resolution, the most important plasma quantities. With regard to feedback algorithms, new model-based controllers were developed to allow a more robust control of several plasma parameters. Both diagnostics and algorithms were successfully used in several experiments, ranging from H-mode plasmas to configuration with ITBs (internal thermal barriers). Since elaboration of computationally heavy measurements is often required, significant attention was devoted to non-algorithmic methods like Digital or Cellular Neural/Nonlinear Networks. The real time hardware and software adopted architectures are also described with particular attention to their relevance to ITER. (authors)

  6. Study on Fault Diagnostics of a Turboprop Engine Using Inverse Performance Model and Artificial Intelligent Methods

    Science.gov (United States)

    Kong, Changduk; Lim, Semyeong

    2011-12-01

    Recently, the health monitoring system of major gas path components of gas turbine uses mostly the model based method like the Gas Path Analysis (GPA). This method is to find quantity changes of component performance characteristic parameters such as isentropic efficiency and mass flow parameter by comparing between measured engine performance parameters such as temperatures, pressures, rotational speeds, fuel consumption, etc. and clean engine performance parameters without any engine faults which are calculated by the base engine performance model. Currently, the expert engine diagnostic systems using the artificial intelligent methods such as Neural Networks (NNs), Fuzzy Logic and Genetic Algorithms (GAs) have been studied to improve the model based method. Among them the NNs are mostly used to the engine fault diagnostic system due to its good learning performance, but it has a drawback due to low accuracy and long learning time to build learning data base if there are large amount of learning data. In addition, it has a very complex structure for finding effectively single type faults or multiple type faults of gas path components. This work builds inversely a base performance model of a turboprop engine to be used for a high altitude operation UAV using measured performance data, and proposes a fault diagnostic system using the base engine performance model and the artificial intelligent methods such as Fuzzy logic and Neural Network. The proposed diagnostic system isolates firstly the faulted components using Fuzzy Logic, then quantifies faults of the identified components using the NN leaned by fault learning data base, which are obtained from the developed base performance model. In leaning the NN, the Feed Forward Back Propagation (FFBP) method is used. Finally, it is verified through several test examples that the component faults implanted arbitrarily in the engine are well isolated and quantified by the proposed diagnostic system.

  7. Isothermal multiple displacement amplification: a methodical approach enhancing molecular routine diagnostics of microcarcinomas and small biopsies

    Directory of Open Access Journals (Sweden)

    Mairinger FD

    2014-08-01

    Full Text Available Fabian D Mairinger,1 Robert FH Walter,2 Claudia Vollbrecht,3 Thomas Hager,1 Karl Worm,1 Saskia Ting,1 Jeremias Wohlschläger,1 Paul Zarogoulidis,4 Konstantinos Zarogoulidis,4 Kurt W Schmid1 1Institute of Pathology, 2Ruhrlandklinik, West German Lung Center, University Hospital Essen, Essen, 3Institute of Pathology, University Hospital Cologne, Cologne, Germany; 4Pulmonary Department, Oncology Unit, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece Background and methods: Isothermal multiple displacement amplification (IMDA can be a powerful tool in molecular routine diagnostics for homogeneous and sequence-independent whole-genome amplification of notably small tumor samples, eg, microcarcinomas and biopsies containing a small amount of tumor. Currently, this method is not well established in pathology laboratories. We designed a study to confirm the feasibility and convenience of this method for routine diagnostics with formalin-fixed, paraffin-embedded samples prepared by laser-capture microdissection. Results: A total of 250 µg DNA (concentration 5 µg/µL was generated by amplification over a period of 8 hours with a material input of approximately 25 cells, approximately equivalent to 175 pg of genomic DNA. In the generated DNA, a representation of all chromosomes could be shown and the presence of elected genes relevant for diagnosis in clinical samples could be proven. Mutational analysis of clinical samples could be performed without any difficulty and showed concordance with earlier diagnostic findings. Conclusion: We established the feasibility and convenience of IMDA for routine diagnostics. We also showed that small amounts of DNA, which were not analyzable with current molecular methods, could be sufficient for a wide field of applications in molecular routine diagnostics when they are preamplified with IMDA. Keywords: isothermal multiple displacement amplification, isothermal, whole

  8. [Diagnostic agreement between two glycosylated a1b hemoglobin methods in Primary Care].

    Science.gov (United States)

    Villar-del-Campo, M C; Rodríguez-Caravaca, G; Gil-Yonte, P; Cidoncha-Calderón, E; García-Cruces Méndez, J; Donnay-Pérez, S

    2014-01-01

    Several methods are available for measuring glycosylated A1c hemoglobin (HbA1c), all rapid methods for point of care use in a clinical or laboratory setting. This study attempts to compare the diagnostic agreement between two methods for detection of HbA1c. A descriptive cross-sectional study of diagnostic agreement was carried out in the Los Carmenes Health Centre. Two groups of patients -with and without type 2 diabetes- were consecutively included. A method for point-of-care use in a Primary Care Clinic setting (DCA(TM) Systems Siemens(®)) was compared with a laboratory test (chromatographic analysis). An analysis was made of the mean concentration of HbA1c, the agreement between methods, using the intra-class correlation coefficient (CCLA1) and the Bland-Altman method. A total of 102 patients were included, 62 diabetic (60.8%) and 40 non-diabetic (39.2%). The overall mean HbA1c was 6.46% (SD=0.88) in the analysis using capillary blood in the clinic with the DCA™ system, and 6.44% (SD=0.86) using the laboratory test (P>.05). The degree of agreement between the two tests was 0.975 (95% CI: 0.963-0.983). The mean of the differences between the results of the two assessed tests was 0.024 (SD=0.27). The percentage of points outside the limits of optimal agreement, as defined in the Bland-Altman graph, was 2.5%. Diagnostic agreement between a method for point-of-care use in a Primary Health Care Clinic and a laboratory test was very high. Detection at the point-of-care allows a quick and simple assessment of HbA1c. Copyright © 2013 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  9. Diagnostic Value of Nineteen Different Imaging Methods for Patients with Breast Cancer: a Network Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Xiao-Hong Zhang

    2018-04-01

    Full Text Available Background/Aims: We performed a network meta-analysis (NMA to investigate and compare the diagnostic value of 19 different imaging methods used for breast cancer (BC. Methods: Cochrane Library, PubMed and EMBASE were searched to collect the relevant literature from the inception of the study until November 2016. A combination of direct and indirect comparisons was performed using an NMA to evaluate the combined odd ratios (OR and draw the surface under the cumulative ranking curves (SUCRA of the diagnostic value of different imaging methods for BC. Results: A total of 39 eligible diagnostic tests regarding 19 imaging methods (mammography [MG], breast-specific gamma imaging [BSGI], color Doppler sonography [CD], contrast-enhanced magnetic resonance imaging [CE-MRI], digital breast tomosynthesis [DBT], fluorodeoxyglucose positron-emission tomography/computed tomography [FDG PET/CT], fluorodeoxyglucose positron-emission tomography [FDG-PET], full field digital mammography [FFDM], handheld breast ultrasound [HHUS], magnetic resonance imaging [MRI], automated breast volume scanner [ABUS], magnetic resonance mammography [MRM], scintimammography [SMM], single photon emission computed tomography scintimammography [SPECT SMM], ultrasound elastography [UE], ultrasonography [US], mammography + ultrasonography [MG + US], mammography + scintimammography [MG + SMM], and ultrasound elastography + ultrasonography [UE + US] were included in the study. According to this network meta-analysis, in comparison to the MG method, the CE-MRI, MRI, MRM, MG + SMM and UE + US methods exhibited relatively higher sensitivity, and the specificity of the FDG PET/CT method was higher, while the BSGI and MRI methods exhibited higher accuracy. Conclusion: The results from this NMA indicate that the diagnostic value of the BSGI, MG + SMM, MRI and CE-MRI methods for BC were relatively higher in terms of sensitivity, specificity and accuracy.

  10. Comparison of sample types and diagnostic methods for in vivo detection of Mycoplasma hyopneumoniae during early stages of infection.

    Science.gov (United States)

    Pieters, Maria; Daniels, Jason; Rovira, Albert

    2017-05-01

    Detection of Mycoplasma hyopneumoniae in live pigs during the early stages of infection is critical for timely implementation of control measures, but is technically challenging. This study compared the sensitivity of various sample types and diagnostic methods for detection of M. hyopneumoniae during the first 28days after experimental exposure. Twenty-one 8-week old pigs were intra-tracheally inoculated on day 0 with M. hyopneumoniae strain 232. Two age matched pigs were mock inoculated and maintained as negative controls. On post-inoculation days 0, 2, 5, 9, 14, 21 and 28, nasal swabs, laryngeal swabs, tracheobronchial lavage fluid, and blood samples were obtained from each pig and oral fluid samples were obtained from each room in which pigs were housed. Serum samples were assayed by ELISA for IgM and IgG M. hyopneumoniae antibodies and C-reactive protein. All other samples were tested for M. hyopneumoniae DNA by species-specific real-time PCR. Serum antibodies (IgG) to M. hyopneumoniae were detected in challenge-inoculated pigs on days 21 and 28. M. hyopneumoniae DNA was detected in samples from experimentally inoculated pigs beginning at 5days post-inoculation. Laryngeal swabs at all samplings beginning on day 5 showed the highest sensitivity for M. hyopneumoniae DNA Detection, while oral fluids showed the lowest sensitivity. Although laryngeal swabs are not considered the typical M. hyopneumoniae diagnostic sample, under the conditions of this study laryngeal swabs tested by PCR proved to be a practical and reliable diagnostic sample for M. hyopneumoniae detection in vivo during early-stage infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. A reliable sewage quality abnormal event monitoring system.

    Science.gov (United States)

    Li, Tianling; Winnel, Melissa; Lin, Hao; Panther, Jared; Liu, Chang; O'Halloran, Roger; Wang, Kewen; An, Taicheng; Wong, Po Keung; Zhang, Shanqing; Zhao, Huijun

    2017-09-15

    With closing water loop through purified recycled water, wastewater becomes a part of source water, requiring reliable wastewater quality monitoring system (WQMS) to manage wastewater source and mitigate potential health risks. However, the development of reliable WQMS is fatally constrained by severe contamination and biofouling of sensors due to the hostile analytical environment of wastewaters, especially raw sewages, that challenges the limit of existing sensing technologies. In this work, we report a technological solution to enable the development of WQMS for real-time abnormal event detection with high reliability and practicality. A vectored high flow hydrodynamic self-cleaning approach and a dual-sensor self-diagnostic concept are adopted for WQMS to effectively encounter vital sensor failing issues caused by contamination and biofouling and ensure the integrity of sensing data. The performance of the WQMS has been evaluated over a 3-year trial period at different sewage catchment sites across three Australian states. It has demonstrated that the developed WQMS is capable of continuously operating in raw sewage for a prolonged period up to 24 months without maintenance and failure, signifying the high reliability and practicality. The demonstrated WQMS capability to reliably acquire real-time wastewater quality information leaps forward the development of effective wastewater source management system. The reported self-cleaning and self-diagnostic concepts should be applicable to other online water quality monitoring systems, opening a new way to encounter the common reliability and stability issues caused by sensor contamination and biofouling. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Structural Reliability Methods for Wind Power Converter System Component Reliability Assessment

    DEFF Research Database (Denmark)

    Kostandyan, Erik; Sørensen, John Dalsgaard

    2012-01-01

    Wind power converter systems are essential subsystems in both off-shore and on-shore wind turbines. It is the main interface between generator and grid connection. This system is affected by numerous stresses where the main contributors might be defined as vibration and temperature loadings....... The temperature variations induce time-varying stresses and thereby fatigue loads. A probabilistic model is used to model fatigue failure for an electrical component in the power converter system. This model is based on a linear damage accumulation and physics of failure approaches, where a failure criterion...... is defined by the threshold model. The attention is focused on crack propagation in solder joints of electrical components due to the temperature loadings. Structural Reliability approaches are used to incorporate model, physical and statistical uncertainties. Reliability estimation by means of structural...

  13. Diagnostic agents containing albumin and methods for making same

    International Nuclear Information System (INIS)

    Saklad, E.L.; Layne, W.W.

    1981-01-01

    This patent specification outlines a method for providing a diagnostic agent for use in radiological testing, comprising the production of an admixture of a source of radionuclide ion (sup(99m)Tc), a reducing agent (source of stannous ions at a pH below 7) and a stabilized, defatted human albumin being sufficiently purified for an aqueous solution not to become cloudy for at least an hour at a pH of 4 or below. Other aspects of the patent provide for a method of producing a radiodiagnostic kit of the above components, packaged in a sealed sterile non-pyrogenic container, and also a method of concentrating sup(99m)Tc in vivo in a target mammalian tissue, by intravenous administration of a mixture of sup(99m)Tc, a reducing agent, and delipidized serum albumin. (U.K.)

  14. Multi-hybrid instrumentations with smartphones and smartpads for innovative in-field and POC diagnostics

    Science.gov (United States)

    Hofmann, Dietrich; Dittrich, Paul-Gerald; Gärtner, Claudia; Klemm, Richard

    2013-03-01

    Aim of the paper is the orientation of research and development on a completely new approach to innovative in-field and point of care diagnostics in industry, biology and medicine. Central functional modules are smartphones and/or smart pads supplemented by additional hardware apps and software apps. Specific examples are given for numerous practical applications concerning optodigital instrumentations. The methodical classification distinguishes between different levels for combination of hardware apps (hwapps) and software apps (swapps) with smartphones and/or smartpads. These methods are fundamental enablers for the transformation from stationary conventional laboratory diagnostics into mobile innovative in-field and point of care diagnostics. The innovative approach opens so far untapped enormous markets due to the convenience, reliability and affordability of smartphone and/or smartpad instruments. A highly visible advantage of smartphones and/or smartpads is the huge number of their distribution, their worldwide connectivity via cloud services and the experienced capability of their users for practical operations.

  15. A Reliability-Oriented Design Method for Power Electronic Converters

    DEFF Research Database (Denmark)

    Wang, Huai; Zhou, Dao; Blaabjerg, Frede

    2013-01-01

    Reliability is a crucial performance indicator of power electronic systems in terms of availability, mission accomplishment and life cycle cost. A paradigm shift in the research on reliability of power electronics is going on from simple handbook based calculations (e.g. models in MIL-HDBK-217F h...... and reliability prediction models are provided. A case study on a 2.3 MW wind power converter is discussed with emphasis on the reliability critical component IGBT modules....

  16. Telepsychiatry clinical decision support system used by non-psychiatrists in remote areas: Validity & reliabilityof diagnostic module

    Directory of Open Access Journals (Sweden)

    Savita Malhotra

    2017-01-01

    Interpretation & conclusions: Diagnostic tool showed acceptable to good validity and reliability when used by non-specialists at remote sites. Our findings show that diagnostic tool of the telepsychiatry application has potential to empower non-psychiatrist doctors and paramedics to diagnose psychiatric disorders accurately and reliably in remote sites.

  17. Sensitivity Weaknesses in Application of some Statistical Distribution in First Order Reliability Methods

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Enevoldsen, I.

    1993-01-01

    It has been observed and shown that in some examples a sensitivity analysis of the first order reliability index results in increasing reliability index, when the standard deviation for a stochastic variable is increased while the expected value is fixed. This unfortunate behaviour can occur when...... a stochastic variable is modelled by an asymmetrical density function. For lognormally, Gumbel and Weibull distributed stochastic variables it is shown for which combinations of the/3-point, the expected value and standard deviation the weakness can occur. In relation to practical application the behaviour...... is probably rather infrequent. A simple example is shown as illustration and to exemplify that for second order reliability methods and for exact calculations of the probability of failure this behaviour is much more infrequent....

  18. Double-contrast imaging of the pharynx in case of dysphagia as the leading symptom. Methodology and diagnostic value

    Energy Technology Data Exchange (ETDEWEB)

    Feyerabend, T; Schmitt, R; Richter, E; Bohndorf, W

    1989-01-01

    The article explains the value of double-contrast pharyngography in the gradual programme of diagnostic means for clarifying the symptom of dysphagia. The method is simple and quick and well suited as a first screening method before more complicated methods are used. It allows reliable assessment of postoperative or postradiogenic morphology in case of malignant oro- or hypopharynx tumors and thus also is suitable for tumor aftercare programmes. (orig./GDG).

  19. Review on Laryngeal Palpation Methods in Muscle Tension Dysphonia: Validity and Reliability Issues.

    Science.gov (United States)

    Khoddami, Seyyedeh Maryam; Ansari, Noureddin Nakhostin; Jalaie, Shohreh

    2015-07-01

    Laryngeal palpation is a common clinical method for the assessment of neck and laryngeal muscles in muscle tension dysphonia (MTD). To review the available laryngeal palpation methods used in patients with MTD for the assessment, diagnosis, or document of treatment outcomes. A systematic review of the literature concerning palpatory methods in MTD was conducted using the databases MEDLINE (PubMed), ScienceDirect, Scopus, Web of science, Web of knowledge and Cochrane Library between July and October 2013. Relevant studies were identified by one reviewer based on screened titles/abstracts and full texts. Manual searching was also used to track the source literature. There were five main as well as miscellaneous palpation methods that were different according to target anatomical structures, judgment or grading system, and using tasks. There were only a few scales available, and the majority of the palpatory methods were qualitative. Most of the palpatory methods evaluate the tension at both static and dynamic tasks. There was little information about the validity and reliability of the available methods. The literature on the scientific evidence of muscle tension indicators perceived by laryngeal palpation in MTD is scarce. Future studies should be conducted to investigate the validity and reliability of palpation methods. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  20. [Knowledge of university students in Szeged, Hungary about reliable contraceptive methods and sexually transmitted diseases].

    Science.gov (United States)

    Devosa, Iván; Kozinszky, Zoltán; Vanya, Melinda; Szili, Károly; Fáyné Dombi, Alice; Barabás, Katalin

    2016-04-03

    Promiscuity and lack of use of reliable contraceptive methods increase the probability of sexually transmitted diseases and the risk of unwanted pregnancies, which are quite common among university students. The aim of the study was to assess the knowledge of university students about reliable contraceptive methods and sexually transmitted diseases, and to assess the effectiveness of the sexual health education in secondary schools, with specific focus on the education held by peers. An anonymous, self-administered questionnaire survey was carried out in a randomized sample of students at the University of Szeged (n = 472, 298 women and 174 men, average age 21 years) between 2009 and 2011. 62.1% of the respondents declared that reproductive health education lessons in high schools held by peers were reliable and authentic source of information, 12.3% considered as a less reliable source, and 25.6% defined the school health education as irrelevant source. Among those, who considered the health education held by peers as a reliable source, there were significantly more females (69.3% vs. 46.6%, p = 0.001), significantly fewer lived in cities (83.6% vs. 94.8%, p = 0.025), and significantly more responders knew that Candida infection can be transmitted through sexual intercourse (79.5% versus 63.9%, p = 0.02) as compared to those who did not consider health education held by peers as a reliable source. The majority of respondents obtained knowledge about sexual issues from the mass media. Young people who considered health educating programs reliable were significantly better informed about Candida disease.

  1. A critical evaluation of deterministic methods in size optimisation of reliable and cost effective standalone hybrid renewable energy systems

    International Nuclear Information System (INIS)

    Maheri, Alireza

    2014-01-01

    Reliability of a hybrid renewable energy system (HRES) strongly depends on various uncertainties affecting the amount of power produced by the system. In the design of systems subject to uncertainties, both deterministic and nondeterministic design approaches can be adopted. In a deterministic design approach, the designer considers the presence of uncertainties and incorporates them indirectly into the design by applying safety factors. It is assumed that, by employing suitable safety factors and considering worst-case-scenarios, reliable systems can be designed. In fact, the multi-objective optimisation problem with two objectives of reliability and cost is reduced to a single-objective optimisation problem with the objective of cost only. In this paper the competence of deterministic design methods in size optimisation of reliable standalone wind–PV–battery, wind–PV–diesel and wind–PV–battery–diesel configurations is examined. For each configuration, first, using different values of safety factors, the optimal size of the system components which minimises the system cost is found deterministically. Then, for each case, using a Monte Carlo simulation, the effect of safety factors on the reliability and the cost are investigated. In performing reliability analysis, several reliability measures, namely, unmet load, blackout durations (total, maximum and average) and mean time between failures are considered. It is shown that the traditional methods of considering the effect of uncertainties in deterministic designs such as design for an autonomy period and employing safety factors have either little or unpredictable impact on the actual reliability of the designed wind–PV–battery configuration. In the case of wind–PV–diesel and wind–PV–battery–diesel configurations it is shown that, while using a high-enough margin of safety in sizing diesel generator leads to reliable systems, the optimum value for this margin of safety leading to a

  2. Diagnostic problems in chest injuries (angiography)

    International Nuclear Information System (INIS)

    Wenz, W.; Strecker, E.P.; Kloehn, I.

    1979-01-01

    Roentgenography is the simplest and most reliable means to arrive at the diagnosis of chest injury. General roentgenograms are difficult to interpret as they tend to be technically imperfect. Fractures, emphysema, pneumothorax, accumulation of fluid can usually be ascertained directly; but the traumatic origin of changes in the pulmonary parenchyma or of an enlarged heart shadow cannot be reliably deduced from the X-ray appearance. It may provide some differential-diagnostic information but the correct interpretation of the findings depends on further observation. In 6-7% of severe chest trauma with vascular injuries and rupture of the diaphragm angiography is indicated. The evidence to be obtained from chest radiography should not be overestimated: fractures of ribs are sometimes overlocked, even by the expert; parenchymatous lesions may manifest themselves as shadows but their nature remains obscure until they have been related to the clinical and subsequent radiological findings. The same applies to rupture of the diaphragm, bronchi or vessels, if only the immediate posttraumatic roentgenographs are examined. A tent-shaped heart shadow is considered characteristic of the presence of fluid in the pericardium; this is valid only for chronic hydropericardium, but not for the potentially fatal cardiac tamponade; if the pericardium has lost its elasticity a haemorrhage of not more than 150 ml may prove fatal. Nor does the roentgenogram provide information about pulmonary function. Especially in cases of pulmonary shock minor changes in the chest roentgenogram may give a false sense of security when, in fact, blood gas analyses show that a life-endangering situation has developed. The radiologist who is aware of the limitations of the method will derive maximum diagnostic benefit from a chest angiography. No other method is capable of supplying information of such great importance in such a short time. (orig.) [de

  3. A reliability design method for a lithium-ion battery pack considering the thermal disequilibrium in electric vehicles

    Science.gov (United States)

    Xia, Quan; Wang, Zili; Ren, Yi; Sun, Bo; Yang, Dezhen; Feng, Qiang

    2018-05-01

    With the rapid development of lithium-ion battery technology in the electric vehicle (EV) industry, the lifetime of the battery cell increases substantially; however, the reliability of the battery pack is still inadequate. Because of the complexity of the battery pack, a reliability design method for a lithium-ion battery pack considering the thermal disequilibrium is proposed in this paper based on cell redundancy. Based on this method, a three-dimensional electric-thermal-flow-coupled model, a stochastic degradation model of cells under field dynamic conditions and a multi-state system reliability model of a battery pack are established. The relationships between the multi-physics coupling model, the degradation model and the system reliability model are first constructed to analyze the reliability of the battery pack and followed by analysis examples with different redundancy strategies. By comparing the reliability of battery packs of different redundant cell numbers and configurations, several conclusions for the redundancy strategy are obtained. More notably, the reliability does not monotonically increase with the number of redundant cells for the thermal disequilibrium effects. In this work, the reliability of a 6 × 5 parallel-series configuration is the optimal system structure. In addition, the effect of the cell arrangement and cooling conditions are investigated.

  4. Software reliability

    CERN Document Server

    Bendell, A

    1986-01-01

    Software Reliability reviews some fundamental issues of software reliability as well as the techniques, models, and metrics used to predict the reliability of software. Topics covered include fault avoidance, fault removal, and fault tolerance, along with statistical methods for the objective assessment of predictive accuracy. Development cost models and life-cycle cost models are also discussed. This book is divided into eight sections and begins with a chapter on adaptive modeling used to predict software reliability, followed by a discussion on failure rate in software reliability growth mo

  5. Reliability and validity in measurement of true humeral retroversion by a three-dimensional cylinder fitting method.

    Science.gov (United States)

    Saka, Masayuki; Yamauchi, Hiroki; Hoshi, Kenji; Yoshioka, Toru; Hamada, Hidetoshi; Gamada, Kazuyoshi

    2015-05-01

    Humeral retroversion is defined as the orientation of the humeral head relative to the distal humerus. Because none of the previous methods used to measure humeral retroversion strictly follow this definition, values obtained by these techniques vary and may be biased by morphologic variations of the humerus. The purpose of this study was 2-fold: to validate a method to define the axis of the distal humerus with a virtual cylinder and to establish the reliability of 3-dimensional (3D) measurement of humeral retroversion by this cylinder fitting method. Humeral retroversion in 14 baseball players (28 humeri) was measured by the 3D cylinder fitting method. The root mean square error was calculated to compare values obtained by a single tester and by 2 different testers using the embedded coordinate system. To establish the reliability, intraclass correlation coefficient (ICC) and precision (standard error of measurement [SEM]) were calculated. The root mean square errors for the humeral coordinate system were reliability and precision of the 3D measurement of retroversion yielded an intratester ICC of 0.99 (SEM, 1.0°) and intertester ICC of 0.96 (SEM, 2.8°). The error in measurements obtained by a distal humerus cylinder fitting method was small enough not to affect retroversion measurement. The 3D measurement of retroversion by this method provides excellent intratester and intertester reliability. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  6. Conceptual transitions in methods of skull-photo superimposition that impact the reliability of identification: a review.

    Science.gov (United States)

    Jayaprakash, Paul T

    2015-01-01

    Establishing identification during skull-photo superimposition relies on correlating the salient morphological features of an unidentified skull with those of a face-image of a suspected dead individual using image overlay processes. Technical progression in the process of overlay has included the incorporation of video cameras, image-mixing devices and software that enables real-time vision-mixing. Conceptual transitions occur in the superimposition methods that involve 'life-size' images, that achieve orientation of the skull to the posture of the face in the photograph and that assess the extent of match. A recent report on the reliability of identification using the superimposition method adopted the currently prevalent methods and suggested an increased rate of failures when skulls were compared with related and unrelated face images. The reported reduction in the reliability of the superimposition method prompted a review of the transition in the concepts that are involved in skull-photo superimposition. The prevalent popular methods for visualizing the superimposed images at less than 'life-size', overlaying skull-face images by relying on the cranial and facial landmarks in the frontal plane when orienting the skull for matching and evaluating the match on a morphological basis by relying on mix-mode alone are the major departures in the methodology that may have reduced the identification reliability. The need to reassess the reliability of the method that incorporates the concepts which have been considered appropriate by the practitioners is stressed. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. MODIFIED ALVARADO SCORING AS A DIAGNOSTIC TOOL IN ACUTE APPENDICITIS- A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    V. K. Arun Kumar

    2017-02-01

    Full Text Available BACKGROUND Acute Appendicitis commonest community-acquired intra-abdominal infections. Acute appendicitis and its associated complications are significant source of morbidity and sometimes mortality. The Modified Alvarado Scoring System (MASS has been reported to be a cheap and quick diagnostic tool in patients with acute appendicitis. Diagnostic accuracy have been observed if the scores were applied to various populations and clinical settings. The purpose of this study was to evaluate the diagnostic value of Modified Alvarado Scoring System in patients with acute appendicitis in our setting. The aim of the study is to evaluate the efficacy of the modified Alvarado score as a diagnostic tool in Acute Appendicitis, as the diagnosis of appendicitis depends on the onset of symptoms and the subjective interpretation of the physical examination. MATERIALS AND METHODS This was a prospective study carried out in Pondicherry Institute of Medical Science during the period of November 2013 to May 2015. This study was done on 50 patients diagnosed with Acute Appendicitis and admitted in General Surgery. RESULTS In this study, there were a total of 50 patients who were taken up for surgery based on clinical and radiological diagnosis. Our study demonstrates that modified Alvarado score applied to all adult patients of acute appendicitis in adults with a sensitivity of 60% and a specificity of 40% only. Showing it wasn’t efficient in diagnosing acute appendicitis. The positive predictive value shown by our study was 80% which is marginally lower than that explained in literature which reports 87.5%. Negative appendicectomy rate in this study is 12%. CONCLUSION Alvarado score is a non-invasive, safe diagnostic procedure, which is simple, fast reliable and repeatable; it can be used in all conditions, without expensive and complicated supportive diagnostic methods. Alvarado score increases the diagnostic certainty of clinical examination in diagnosis of

  8. Competitive Protein-binding assay-based Enzyme-immunoassay Method, Compared to High-pressure Liquid Chromatography, Has a Very Lower Diagnostic Value to Detect Vitamin D Deficiency in 9-12 Years Children.

    Science.gov (United States)

    Zahedi Rad, Maliheh; Neyestani, Tirang Reza; Nikooyeh, Bahareh; Shariatzadeh, Nastaran; Kalayi, Ali; Khalaji, Niloufar; Gharavi, Azam

    2015-01-01

    The most reliable indicator of Vitamin D status is circulating concentration of 25-hydroxycalciferol (25(OH) D) routinely determined by enzyme-immunoassays (EIA) methods. This study was performed to compare commonly used competitive protein-binding assays (CPBA)-based EIA with the gold standard, high-pressure liquid chromatography (HPLC). Concentrations of 25(OH) D in sera from 257 randomly selected school children aged 9-11 years were determined by two methods of CPBA and HPLC. Mean 25(OH) D concentration was 22 ± 18.8 and 21.9 ± 15.6 nmol/L by CPBA and HPLC, respectively. However, mean 25(OH) D concentrations of the two methods became different after excluding undetectable samples (25.1 ± 18.9 vs. 29 ± 14.5 nmol/L, respectively; P = 0.04). Based on predefined Vitamin D deficiency as 25(OH) D < 12.5 nmol/L, CPBA sensitivity and specificity were 44.2% and 60.6%, respectively, compared to HPLC. In receiver operating characteristic curve analysis, the best cut-offs for CPBA was 5.8 nmol/L, which gave 82% sensitivity, but specificity was 17%. Though CPBA may be used as a screening tool, more reliable methods are needed for diagnostic purposes.

  9. Method for remote diagnostics of the internal structure of layered media

    International Nuclear Information System (INIS)

    Lychagov, V V; Kal'yanov, A L; Ryabukho, V P; Lyakin, D V

    2008-01-01

    The method of autocorrelation low coherence interferometry is proposed for diagnostics of inhomogeneities and the internal structure of layered technical and biological samples. In this method the low coherence optical field reflected from the layered sample is analysed by using a Michelson interferometer. Because the object is outside the interferometer, the distance between the interferometer and the object under study is not limited and thus the object can move during the measurements. Theoretical substantiation of the autocorrelation method for media with discrete and continuous optical structure modifications is presented. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

  10. White-Nose Syndrome Disease Severity and a Comparison of Diagnostic Methods.

    Science.gov (United States)

    McGuire, Liam P; Turner, James M; Warnecke, Lisa; McGregor, Glenna; Bollinger, Trent K; Misra, Vikram; Foster, Jeffrey T; Frick, Winifred F; Kilpatrick, A Marm; Willis, Craig K R

    2016-03-01

    White-nose syndrome is caused by the fungus Pseudogymnoascus destructans and has killed millions of hibernating bats in North America but the pathophysiology of the disease remains poorly understood. Our objectives were to (1) assess non-destructive diagnostic methods for P. destructans infection compared to histopathology, the current gold-standard, and (2) to evaluate potential metrics of disease severity. We used data from three captive inoculation experiments involving 181 little brown bats (Myotis lucifugus) to compare histopathology, quantitative PCR (qPCR), and ultraviolet fluorescence as diagnostic methods of P. destructans infection. To assess disease severity, we considered two histology metrics (wing area with fungal hyphae, area of dermal necrosis), P. destructans fungal load (qPCR), ultraviolet fluorescence, and blood chemistry (hematocrit, sodium, glucose, pCO2, and bicarbonate). Quantitative PCR was most effective for early detection of P. destructans, while all three methods were comparable in severe infections. Correlations among hyphae and necrosis scores, qPCR, ultraviolet fluorescence, blood chemistry, and hibernation duration indicate a multi-stage pattern of disease. Disruptions of homeostasis occurred rapidly in late hibernation. Our results provide valuable information about the use of non-destructive techniques for monitoring, and provide novel insight into the pathophysiology of white-nose syndrome, with implications for developing and implementing potential mitigation strategies.

  11. Noninvasive diagnostic methods for perceptual and motor disabilities in children with cerebral palsy

    Directory of Open Access Journals (Sweden)

    Renee Lampe

    2009-09-01

    Full Text Available The field of neuroorthopedics centers on chronic diseases demanding close clinical monitoring. We shall use several examples to show how the various noninvasive diagnostic instruments can be used to obtain insight into the central nervous system as well as into the musculoskeletal system and its morphology. The choice of the most appropriate method depends on the problem; that is, whether the method is to be applied for clinical use or for basic research. In this report we introduce various technical examination methods that are being used successfully in the fields of pediatrics, orthopedics, and neurology. The major examination instrument in pediatric diagnostics is sonography, which is being used in this report as a research instrument for the biomechanics of the musculoskeletal system, but which also gives insight into neurofunctional sequences. In orthopedics, pedography is used for diagnosing deformities of the feet. In neuroorthopedics for children pedography acts as a functional monitor for apraxia and thus allows, for example, a classification of the degree of neurological malfunctions in the lower extremities. The 3D bodyscan is used to minimize x-raying in patients with neurogenic scoliosis. This report introduces examples of the application of MRI and fMRI for basic research. The biometric measuring methods introduced provide precise data in the areas of diagnostics and monitoring and are highly valuable for further neuroorthopedic basic research. In future we expect the ever-evolving technical measuring methods to enable a deeper understanding of the primary neurological causes of and the implications for patients with cerebral palsy and other neuroorthopedic conditions. This may allow the development of new forms of therapy not necessarily predictable today.

  12. Procedures for controlling the risks of reliability, safety, and availability of technical systems

    International Nuclear Information System (INIS)

    1987-01-01

    The reference book covers four sections. Apart from the fundamental aspects of the reliability problem, of risk and safety and the relevant criteria with regard to reliability, the material presented explains reliability in terms of maintenance, logistics and availability, and presents procedures for reliability assessment and determination of factors influencing the reliability, together with suggestions for systems technical integration. The reliability assessment consists of diagnostic and prognostic analyses. The section on factors influencing reliability discusses aspects of organisational structures, programme planning and control, and critical activities. (DG) [de

  13. Exploratory factor analysis and reliability analysis with missing data: A simple method for SPSS users

    Directory of Open Access Journals (Sweden)

    Bruce Weaver

    2014-09-01

    Full Text Available Missing data is a frequent problem for researchers conducting exploratory factor analysis (EFA or reliability analysis. The SPSS FACTOR procedure allows users to select listwise deletion, pairwise deletion or mean substitution as a method for dealing with missing data. The shortcomings of these methods are well-known. Graham (2009 argues that a much better way to deal with missing data in this context is to use a matrix of expectation maximization (EM covariances(or correlations as input for the analysis. SPSS users who have the Missing Values Analysis add-on module can obtain vectors ofEM means and standard deviations plus EM correlation and covariance matrices via the MVA procedure. But unfortunately, MVA has no /MATRIX subcommand, and therefore cannot write the EM correlations directly to a matrix dataset of the type needed as input to the FACTOR and RELIABILITY procedures. We describe two macros that (in conjunction with an intervening MVA command carry out the data management steps needed to create two matrix datasets, one containing EM correlations and the other EM covariances. Either of those matrix datasets can then be used asinput to the FACTOR procedure, and the EM correlations can also be used as input to RELIABILITY. We provide an example that illustrates the use of the two macros to generate the matrix datasets and how to use those datasets as input to the FACTOR and RELIABILITY procedures. We hope that this simple method for handling missing data will prove useful to both students andresearchers who are conducting EFA or reliability analysis.

  14. A Method to Increase Drivers' Trust in Collision Warning Systems Based on Reliability Information of Sensor

    Science.gov (United States)

    Tsutsumi, Shigeyoshi; Wada, Takahiro; Akita, Tokihiko; Doi, Shun'ichi

    Driver's workload tends to be increased during driving under complicated traffic environments like a lane change. In such cases, rear collision warning is effective for reduction of cognitive workload. On the other hand, it is pointed out that false alarm or missing alarm caused by sensor errors leads to decrease of driver' s trust in the warning system and it can result in low efficiency of the system. Suppose that reliability information of the sensor is provided in real-time. In this paper, we propose a new warning method to increase driver' s trust in the system even with low sensor reliability utilizing the sensor reliability information. The effectiveness of the warning methods is shown by driving simulator experiments.

  15. Safety and reliability analysis based on nonprobabilistic methods

    International Nuclear Information System (INIS)

    Kozin, I.O.; Petersen, K.E.

    1996-01-01

    Imprecise probabilities, being developed during the last two decades, offer a considerably more general theory having many advantages which make it very promising for reliability and safety analysis. The objective of the paper is to argue that imprecise probabilities are more appropriate tool for reliability and safety analysis, that they allow to model the behavior of nuclear industry objects more comprehensively and give a possibility to solve some problems unsolved in the framework of conventional approach. Furthermore, some specific examples are given from which we can see the usefulness of the tool for solving some reliability tasks

  16. Temperature diagnostics of a non-thermal plasma jet at atmospheric pressure

    Science.gov (United States)

    Schäfer, Jan

    2013-09-01

    The study reflects the concept of the temperature as a physical quantity resulting from the second thermodynamic law. The reliability of different approaches of the temperature diagnostics of open non-equilibrium systems is discussed using examples of low temperature atmospheric pressure discharges. The focus of this work is a miniaturized non-thermal atmospheric pressure plasma jet for local surface treatment at ambient atmosphere. The micro-discharge is driven with a capacitively coupled radio frequency electric field at 27.12 MHz and fed with argon at rates of about 1 slm through the capillary with an inner diameter of 4 mm. The discharge consists of several contracted filaments with diameter around 300 μm which are rotating azimuthally in the capillary in a self-organized manner. While the measured temperatures of the filament core exceed 700 K, the heat impact on a target below the plasma jet remains limited leading to target temperatures below 400 K. Different kinds of temperatures and energy transport processes are proposed and experimentally investigated. Nevertheless, a reliable and detailed temperature diagnostics is a challenge. We report on a novel diagnostics approach for the spatially and temporally resolved measurement of the gas temperature based on the optical properties of the plasma. Laser Schlieren Deflectometry is adapted to explore temperature profiles of filaments and their behaviour. In parallel, the method demonstrates a fundamental Fermat's principle of minimal energy. Information acquired with this method plays an important role for the optimization of local thin film deposition and surface functionalization by means of the atmospheric pressure plasma jet. The work was supported in part by the Deutsche Forschungsgemeinschaft within SFB-TR 24.

  17. Validity and reliability of a method for assessment of cervical vertebral maturation.

    Science.gov (United States)

    Zhao, Xiao-Guang; Lin, Jiuxiang; Jiang, Jiu-Hui; Wang, Qingzhu; Ng, Sut Hong

    2012-03-01

    To evaluate the validity and reliability of the cervical vertebral maturation (CVM) method with a longitudinal sample. Eighty-six cephalograms from 18 subjects (5 males and 13 females) were selected from the longitudinal database. Total mandibular length was measured on each film; an increased rate served as the gold standard in examination of the validity of the CVM method. Eleven orthodontists, after receiving intensive training in the CVM method, evaluated all films twice. Kendall's W and the weighted kappa statistic were employed. Kendall's W values were higher than 0.8 at both times, indicating strong interobserver reproducibility, but interobserver agreement was documented twice at less than 50%. A wide range of intraobserver agreement was noted (40.7%-79.1%), and substantial intraobserver reproducibility was proved by kappa values (0.53-0.86). With regard to validity, moderate agreement was reported between the gold standard and observer staging at the initial time (kappa values 0.44-0.61). However, agreement seemed to be unacceptable for clinical use, especially in cervical stage 3 (26.8%). Even though the validity and reliability of the CVM method proved statistically acceptable, we suggest that many other growth indicators should be taken into consideration in evaluating adolescent skeletal maturation.

  18. DIAGNOSTIC CARDIAC CATHETERIZATION USING THE MEDRAD AVANTA FLUID MANAGEMENT SYSTEM AS COMPARED TO THE TRADITIONAL MANUAL INJECTION METHOD

    Energy Technology Data Exchange (ETDEWEB)

    Winniford, Michael D

    2013-02-08

    Nearly 4 million patient procedures performed annually in US cardiac catheterization laboratories utilize contrast media to achieve vessel opacification. The amount of contrast media used is variable and depends on the complexity of the procedure, the method of contrast delivery as well as the skill-level of the operator. Since the total amount of contrast used for each procedure can have both patient safety and economic implications, it is essential for cardiologists to have the ability to control contrast delivery such that optimal angiographic image quality is achieved using the least amount of contrast. Although the complication rate associated with cardiac catheterization remains low, the most common serious complication, contrast-induced nephropathy (CIN), is associated with poor prognosis and a high mortality rate. Numerous interventional strategies for preventing and reducing the severity of CIN have demonstrated varying degrees of clinical benefit, but none has been shown to reliably prevent this serious complication. To date, the most effective approach for reducing the risk of CIN is to properly hydrate the patient and to minimize the amount of contrast media administered. Automated injection systems are intended for use in virtually all cardiac catheterization procedures and have numerous features which can provide potential advantages over traditional methods. With automated injection technology the operator is able to control and precisely monitor contrast delivery. Additionally, the MEDRAD Avanta Fluid Management Injection System utilizes a sterile contrast reservoir which eliminates the need to discard unused contrast in individual opened containers following each procedure. Considering that an average of 50% of opened contrast media is wasted using manual injection methods, this savings can provide a substantial economic benefit. Automated systems also facilitate the use of smaller (5 French) catheter sizes. Precise flow control and the use of

  19. Reliability evaluation of oil pipelines operating in aggressive environment

    Science.gov (United States)

    Magomedov, R. M.; Paizulaev, M. M.; Gebel, E. S.

    2017-08-01

    In connection with modern increased requirements for ecology and safety, the development of diagnostic services complex is obligatory and necessary enabling to ensure the reliable operation of the gas transportation infrastructure. Estimation of oil pipelines technical condition should be carried out not only to establish the current values of the equipment technological parameters in operation, but also to predict the dynamics of changes in the physical and mechanical characteristics of the material, the appearance of defects, etc. to ensure reliable and safe operation. In the paper, existing Russian and foreign methods for evaluation of the oil pipelines reliability are considered, taking into account one of the main factors leading to the appearance of crevice in the pipeline material, i.e. change the shape of its cross-section, - corrosion. Without compromising the generality of the reasoning, the assumption of uniform corrosion wear for the initial rectangular cross section has been made. As a result a formula for calculation the probability of failure-free operation was formulated. The proposed mathematical model makes it possible to predict emergency situations, as well as to determine optimal operating conditions for oil pipelines.

  20. Diagnostic classification past, present, and future: implications for pharmacotherapy.

    Science.gov (United States)

    Howland, Robert H

    2013-04-01

    Making a diagnosis is a key step in understanding the natural course of a disorder, selecting an appropriate treatment for the disorder, and predicting its response to treatment. Diagnostic proposals can be evaluated in two ways: reliability and validity. The reliability and validity of diagnoses are not one and the same, although establishing reliability is usually a necessary step before being able to evaluate and determine validity. There is little evidence that most psychiatric diagnoses are valid, but the reliability of diagnoses using classification systems developed since 1970 have greatly improved and are important for clinical practice and research. Past and current diagnostic systems have not optimally assisted the search for disorder-specific pathophysiological mechanisms, and they do not provide the specificity that clinicians would like when selecting medication. The Research Domain Criteria project is intended to shift research away from categorical diagnoses to focus on dysregulated neurobiological systems, and this approach ultimately may be more useful for understanding the pathophysiology of mental disorders and improving the development and use of treatment interventions. Copyright 2013, SLACK Incorporated.

  1. ICF implosion hotspot ion temperature diagnostic techniques based on neutron time-of-flight method

    International Nuclear Information System (INIS)

    Tang Qi; Song Zifeng; Chen Jiabin; Zhan Xiayu

    2013-01-01

    Ion temperature of implosion hotspot is a very important parameter for inertial confinement fusion. It reflects the energy level of the hotspot, and it is very sensitive to implosion symmetry and implosion speed. ICF implosion hotspot ion temperature diagnostic techniques based on neutron time-of-flight method were described. A neutron TOF spectrometer was developed using a ultrafast plastic scintillator as the neutron detector. Time response of the spectrometer has 1.1 ns FWHM and 0.5 ns rising time. TOF spectrum resolving method based on deconvolution and low pass filter was illuminated. Implosion hotspot ion temperature in low neutron yield and low ion temperature condition at Shenguang-Ⅲ facility was acquired using the diagnostic techniques. (authors)

  2. [Cytology in uropathological diagnostics].

    Science.gov (United States)

    Gaisa, N T; Lindemann-Docter, K

    2015-11-01

    Cytology in uropathological diagnostics is mainly performed for oncological purposes. The assessment of malignancy by urothelial cell morphology is therefore decisive; however, cytology is only sensitive enough to detect high-grade tumor cells and the different low-grade tumors cannot be reliably diagnosed. Thus, the four-tier classification system of cytological findings (i.e. negative, atypical cells but significance uncertain, suspicious and positive) refers to high-grade tumor cells only. Furthermore, for valid cytological diagnostics not only the cytological specimen but also clinical information on cystoscopy findings and, if applicable, a biopsy should be evaluated together. In difficult differential diagnostic settings, e.g. differentiation between reactive versus neoplastic atypia or difficult to access lesions in the upper urinary tract, additional fluorescence in situ hybridization of cytological preparations might be helpful. At the moment there are no indications for further immunocytology or additional biomarker tests.

  3. The Methodological Aspect of the Diagnostics of Objects in Economics

    Directory of Open Access Journals (Sweden)

    Grynko Pavlo О.

    2017-12-01

    Full Text Available The article on the basis of morphological analysis defines the concept of «diagnostics in economics». The differences of diagnostics in economics, economic diagnostics, and analysis in economics were analyzed. The types, functions, principles of diagnostics in economics in modern conditions have been substantiated. The interrelationship of diagnostics with other functions of management in economics has been concretized. The logic and contents of stages of the diagnostic technology in economics have been clarified. The reliability of diagnostics in economics is determined by analytical tools, which are applicable in its implementation. Recommendations of analytical tools for realization of diagnostics in economics have been substantiated. A structural-logical scheme of diagnostics in economics, firming its scientific base and providing objectivity in practical implementation has been proposed.

  4. Reliability and validity of a brief method to assess nociceptive flexion reflex (NFR) threshold.

    Science.gov (United States)

    Rhudy, Jamie L; France, Christopher R

    2011-07-01

    The nociceptive flexion reflex (NFR) is a physiological tool to study spinal nociception. However, NFR assessment can take several minutes and expose participants to repeated suprathreshold stimulations. The 4 studies reported here assessed the reliability and validity of a brief method to assess NFR threshold that uses a single ascending series of stimulations (Peak 1 NFR), by comparing it to a well-validated method that uses 3 ascending/descending staircases of stimulations (Staircase NFR). Correlations between the NFR definitions were high, were on par with test-retest correlations of Staircase NFR, and were not affected by participant sex or chronic pain status. Results also indicated the test-retest reliabilities for the 2 definitions were similar. Using larger stimulus increments (4 mAs) to assess Peak 1 NFR tended to result in higher NFR threshold estimates than using the Staircase NFR definition, whereas smaller stimulus increments (2 mAs) tended to result in lower NFR threshold estimates than the Staircase NFR definition. Neither NFR definition was correlated with anxiety, pain catastrophizing, or anxiety sensitivity. In sum, a single ascending series of electrical stimulations results in a reliable and valid estimate of NFR threshold. However, caution may be warranted when comparing NFR thresholds across studies that differ in the ascending stimulus increments. This brief method to assess NFR threshold is reliable and valid; therefore, it should be useful to clinical pain researchers interested in quickly assessing inter- and intra-individual differences in spinal nociceptive processes. Copyright © 2011 American Pain Society. Published by Elsevier Inc. All rights reserved.

  5. Development of A Standard Method for Human Reliability Analysis of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Jung, Won Dea; Kang, Dae Il; Kim, Jae Whan

    2005-12-01

    According as the demand of risk-informed regulation and applications increase, the quality and reliability of a probabilistic safety assessment (PSA) has been more important. KAERI started a study to standardize the process and the rules of HRA (Human Reliability Analysis) which was known as a major contributor to the uncertainty of PSA. The study made progress as follows; assessing the level of quality of the HRAs in Korea and identifying the weaknesses of the HRAs, determining the requirements for developing a standard HRA method, developing the process and rules for quantifying human error probability. Since the risk-informed applications use the ASME PSA standard to ensure PSA quality, the standard HRA method was developed to meet the ASME HRA requirements with level of category II. The standard method was based on THERP and ASEP HRA that are widely used for conventional HRA. However, the method focuses on standardizing and specifying the analysis process, quantification rules and criteria to minimize the deviation of the analysis results caused by different analysts. Several HRA experts from different organizations in Korea participated in developing the standard method. Several case studies were interactively undertaken to verify the usability and applicability of the standard method

  6. Development of A Standard Method for Human Reliability Analysis of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Won Dea; Kang, Dae Il; Kim, Jae Whan

    2005-12-15

    According as the demand of risk-informed regulation and applications increase, the quality and reliability of a probabilistic safety assessment (PSA) has been more important. KAERI started a study to standardize the process and the rules of HRA (Human Reliability Analysis) which was known as a major contributor to the uncertainty of PSA. The study made progress as follows; assessing the level of quality of the HRAs in Korea and identifying the weaknesses of the HRAs, determining the requirements for developing a standard HRA method, developing the process and rules for quantifying human error probability. Since the risk-informed applications use the ASME PSA standard to ensure PSA quality, the standard HRA method was developed to meet the ASME HRA requirements with level of category II. The standard method was based on THERP and ASEP HRA that are widely used for conventional HRA. However, the method focuses on standardizing and specifying the analysis process, quantification rules and criteria to minimize the deviation of the analysis results caused by different analysts. Several HRA experts from different organizations in Korea participated in developing the standard method. Several case studies were interactively undertaken to verify the usability and applicability of the standard method.

  7. Methods to determine fast-ion distribution functions from multi-diagnostic measurements

    DEFF Research Database (Denmark)

    Jacobsen, Asger Schou; Salewski, Mirko

    -ion diagnostic views, it is possible to infer the distribution function using a tomography approach. Several inversion methods for solving this tomography problem in velocity space are implemented and compared. It is found that the best quality it obtained when using inversion methods which penalise steep......Understanding the behaviour of fast ions in a fusion plasma is very important, since the fusion-born alpha particles are expected to be the main source of heating in a fusion power plant. Preferably, the entire fast-ion velocity-space distribution function would be measured. However, no fast...

  8. Magnetic resonance imaging of the wrist: Diagnostic performance statistics

    International Nuclear Information System (INIS)

    Hobby, Jonathan L.; Tom, Brian D.M.; Bearcroft, Philip W.P.; Dixon, Adrian K.

    2001-01-01

    AIM: To review the published diagnostic performance statistics for magnetic resonance imaging (MRI) of the wrist for tears of the triangular fibrocartilage complex, the intrinsic carpal ligaments, and for osteonecrosis of the carpal bones. MATERIALS AND METHODS: We used Medline and Embase to search the English language literature. Studies evaluating the diagnostic performance of MRI of the wrist in living patients with surgical confirmation of MR findings were identified. RESULTS: We identified 11 studies reporting the diagnostic performance of MRI for tears of the triangular fibrocartilage complex for a total of 410 patients, six studies for the scapho-lunate ligament (159 patients), six studies for the luno-triquetral ligament (142 patients) and four studies (56 patients) for osteonecrosis of the carpal bones. CONCLUSIONS: Magnetic resonance imaging is an accurate means of diagnosing tears of the triangular fibrocartilage and carpal osteonecrosis. Although MRI is highly specific for tears of the intrinsic carpal ligaments, its sensitivity is low. The diagnostic performance of MRI in the wrist is improved by using high-resolution T2* weighted 3D gradient echo sequences. Using current imaging techniques without intra-articular contrast medium, magnetic resonance imaging cannot reliably exclude tears of the intrinsic carpal ligaments. Hobby, J.L. (2001)

  9. Reliability of Semiautomated Computational Methods for Estimating Tibiofemoral Contact Stress in the Multicenter Osteoarthritis Study

    Directory of Open Access Journals (Sweden)

    Donald D. Anderson

    2012-01-01

    Full Text Available Recent findings suggest that contact stress is a potent predictor of subsequent symptomatic osteoarthritis development in the knee. However, much larger numbers of knees (likely on the order of hundreds, if not thousands need to be reliably analyzed to achieve the statistical power necessary to clarify this relationship. This study assessed the reliability of new semiautomated computational methods for estimating contact stress in knees from large population-based cohorts. Ten knees of subjects from the Multicenter Osteoarthritis Study were included. Bone surfaces were manually segmented from sequential 1.0 Tesla magnetic resonance imaging slices by three individuals on two nonconsecutive days. Four individuals then registered the resulting bone surfaces to corresponding bone edges on weight-bearing radiographs, using a semi-automated algorithm. Discrete element analysis methods were used to estimate contact stress distributions for each knee. Segmentation and registration reliabilities (day-to-day and interrater for peak and mean medial and lateral tibiofemoral contact stress were assessed with Shrout-Fleiss intraclass correlation coefficients (ICCs. The segmentation and registration steps of the modeling approach were found to have excellent day-to-day (ICC 0.93–0.99 and good inter-rater reliability (0.84–0.97. This approach for estimating compartment-specific tibiofemoral contact stress appears to be sufficiently reliable for use in large population-based cohorts.

  10. IR IMAGING AND VIBRATORY METHODS OF CONTROL AND DIAGNOSTICS OF THE EQUIPMENT AT OJSC «BSW – MANAGEMENT COMPANY OF HOLDING «BMC»

    Directory of Open Access Journals (Sweden)

    A. S. Shinkarev

    2017-01-01

    Full Text Available The article discusses the main methods of diagnostics of the equipment of OJSC «BSW – management company of holding «BMC». Presents results of diagnostics of various equipment with the description of the devices directly used for the diagnostic that can detect various defects of the equipment at the stage of their origination. Describes the advantages of these methods compared to other methods of control and diagnostics.

  11. Machine Maintenance Scheduling with Reliability Engineering Method and Maintenance Value Stream Mapping

    Science.gov (United States)

    Sembiring, N.; Nasution, A. H.

    2018-02-01

    Corrective maintenance i.e replacing or repairing the machine component after machine break down always done in a manufacturing company. It causes the production process must be stopped. Production time will decrease due to the maintenance team must replace or repair the damage machine component. This paper proposes a preventive maintenance’s schedule for a critical component of a critical machine of an crude palm oil and kernel company due to increase maintenance efficiency. The Reliability Engineering & Maintenance Value Stream Mapping is used as a method and a tool to analize the reliability of the component and reduce the wastage in any process by segregating value added and non value added activities.

  12. Reliable method for fission source convergence of Monte Carlo criticality calculation with Wielandt's method

    International Nuclear Information System (INIS)

    Yamamoto, Toshihiro; Miyoshi, Yoshinori

    2004-01-01

    A new algorithm of Monte Carlo criticality calculations for implementing Wielandt's method, which is one of acceleration techniques for deterministic source iteration methods, is developed, and the algorithm can be successfully implemented into MCNP code. In this algorithm, part of fission neutrons emitted during random walk processes are tracked within the current cycle, and thus a fission source distribution used in the next cycle spread more widely. Applying this method intensifies a neutron interaction effect even in a loosely-coupled array where conventional Monte Carlo criticality methods have difficulties, and a converged fission source distribution can be obtained with fewer cycles. Computing time spent for one cycle, however, increases because of tracking fission neutrons within the current cycle, which eventually results in an increase of total computing time up to convergence. In addition, statistical fluctuations of a fission source distribution in a cycle are worsened by applying Wielandt's method to Monte Carlo criticality calculations. However, since a fission source convergence is attained with fewer source iterations, a reliable determination of convergence can easily be made even in a system with a slow convergence. This acceleration method is expected to contribute to prevention of incorrect Monte Carlo criticality calculations. (author)

  13. The Spanish version of the 2010 American College of Rheumatology Preliminary Diagnostic Criteria for fibromyalgia: reliability and validity assessment.

    Science.gov (United States)

    Casanueva, Benigno; García-Fructuoso, Ferrán; Belenguer, Rafael; Alegre, Cayetano; Moreno-Muelas, José V; Hernández, José L; Pina, Tinitario; González-Gay, Miguel Á

    2016-01-01

    To investigate the reliability and validity of the Spanish version of the 2010 American College of Rheumatology (ACR) Preliminary Diagnostic Criteria for Fibromyalgia (FM) in patients with chronic pain. The 2010 ACR Preliminary Diagnostic Criteria for FM were adapted to a Spanish version following the guidelines of the Rheumatology Spanish Society Study Group of FM. Based on the 1990 ACR classi cation criteria for FM, patients with chronic pain were initially divided into two groups: a FM group and another group of non-FM individuals. Patients from the FM group were evaluated by tender points (TP) examination, Fibromyalgia Impact Questionnaire (FIQ), Widespread Pain Index (WPI), and Symptom Severity Scale (SSS). The non-FM (control) group included patients with rheumatoid arthritis (RA) and osteoarthritis (OA). They were evaluated by WPI and SSS. We included 1,169 patients divided into two groups: FM group (n=803; 777 women and 26 men) and non-FM group (n= 366; 147 patients with RA, and 219 with OA). The median value of TP and FIQ in the FM group was 16 and 74 respectively. The preliminary 2010 ACR criteria were met by 665 (82.8%) FM patients and by 112 (30.6%) patients from the non-FM group (pFIQ (p<0.0001), WPI (p<0.0001) and SSS (p<0.0001) were observed when FM patients fulfilling the 2010 ACR criteria were compared with the remaining FM patients who did not fulfill these criteria. Sensitivity of the Spanish version of the 2010 ACR criteria was 85.6% (95%CI: 83.1-88.1), speci city 73.2% (95%CI: 68.4-78), positive predictive value 87.7% (95%CI: 85.3-90.1) and negative predictive value 69.4% (95%CI: 64.5-74.2). Our results indicate that the 2010 ACR Preliminary Diagnostic Criteria for FM may be useful to establish a diagnosis of FM in Spanish individuals with chronic pain.

  14. Studies on WWER core diagnostics

    International Nuclear Information System (INIS)

    Lunin, G.L.; Mitin, V.I.; Bulavin, V.V.

    1987-01-01

    The reliability and safety of nuclear power plants have decisive meaning under the situation that nuclear power generation steadily increases, and among various measures aiming at ensuring the reliability and safety in the operation of nuclear power plants, the countermeasures for protecting reactor core, main process equipment and high pressure circuits from damage have the important role, and the monitoring of condition and the organization of forecast, which are carried out continuously or periodically during the operation of nuclear power stations using the diagnostic expert system specially developed for the purpose, are included in them. Such monitoring enables the early detection of mechanical damage, increase of vibration, defects caused during operation and so on in reactor cores and primary and secondary circuits, and the continuous watching of defect developments. Also boiling in a core is detected, the place of abnormality occurrence is identified, and the intensity and characteristics of boiling are determined, thus the occurrence of dangerous condition is prevented. The developments of an in-core monitoring system and noise diagnostic systems are reported. (Kako, I.)

  15. A fracture mechanics and reliability based method to assess non-destructive testings for pressure vessels

    International Nuclear Information System (INIS)

    Kitagawa, Hideo; Hisada, Toshiaki

    1979-01-01

    Quantitative evaluation has not been made on the effects of carrying out preservice and in-service nondestructive tests for securing the soundness, safety and maintainability of pressure vessels, spending large expenses and labor. Especially the problems concerning the time and interval of in-service inspections lack the reasonable, quantitative evaluation method. In this paper, the problems of pressure vessels are treated by having developed the analysis method based on reliability technology and probability theory. The growth of surface cracks in pressure vessels was estimated, using the results of previous studies. The effects of nondestructive inspection on the defects in pressure vessels were evaluated, and the influences of many factors, such as plate thickness, stress, the accuracy of inspection and so on, on the effects of inspection, and the method of evaluating the inspections at unequal intervals were investigated. The analysis of reliability taking in-service inspection into consideration, the evaluation of in-service inspection and other affecting factors through the typical examples of analysis, and the review concerning the time of inspection are described. The method of analyzing the reliability of pressure vessels, considering the growth of defects and preservice and in-service nondestructive tests, was able to be systematized so as to be practically usable. (Kako, I.)

  16. Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection

    Directory of Open Access Journals (Sweden)

    Han Yih Lau

    2017-12-01

    Full Text Available Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care diagnostic methods for applications in plant disease detection. Polymerase chain reaction (PCR is the most common DNA amplification technology used for detecting various plant and animal pathogens. However, subsequent to PCR based assays, several types of nucleic acid amplification technologies have been developed to achieve higher sensitivity, rapid detection as well as suitable for field applications such as loop-mediated isothermal amplification, helicase-dependent amplification, rolling circle amplification, recombinase polymerase amplification, and molecular inversion probe. The principle behind these technologies has been thoroughly discussed in several review papers; herein we emphasize the application of these technologies to detect plant pathogens by outlining the advantages and disadvantages of each technology in detail.

  17. Applicability of simplified human reliability analysis methods for severe accidents

    Energy Technology Data Exchange (ETDEWEB)

    Boring, R.; St Germain, S. [Idaho National Lab., Idaho Falls, Idaho (United States); Banaseanu, G.; Chatri, H.; Akl, Y. [Canadian Nuclear Safety Commission, Ottawa, Ontario (Canada)

    2016-03-15

    Most contemporary human reliability analysis (HRA) methods were created to analyse design-basis accidents at nuclear power plants. As part of a comprehensive expansion of risk assessments at many plants internationally, HRAs will begin considering severe accident scenarios. Severe accidents, while extremely rare, constitute high consequence events that significantly challenge successful operations and recovery. Challenges during severe accidents include degraded and hazardous operating conditions at the plant, the shift in control from the main control room to the technical support center, the unavailability of plant instrumentation, and the need to use different types of operating procedures. Such shifts in operations may also test key assumptions in existing HRA methods. This paper discusses key differences between design basis and severe accidents, reviews efforts to date to create customized HRA methods suitable for severe accidents, and recommends practices for adapting existing HRA methods that are already being used for HRAs at the plants. (author)

  18. Advanced Optical Diagnostic Methods for Describing Fuel Injection and Combustion Flowfield Phenomena

    Science.gov (United States)

    Locke, Randy J.; Hicks, Yolanda R.; Anderson, Robert C.

    2004-01-01

    resulted from this feedback. Alternate diagnostic methods are constantly being evaluated as to their suitability as a diagnostic tool in these environments. A new method currently under examination is background oriented Schlieren (BOS) for examining the fuel/air mixing processes. While ratioing the Stokes and anti-Stokes nitrogen lines obtained from spontaneous Raman is being refined for temperature measurement. While the primary focus of the GRC diagnostic work remains optical species measurement and flow stream characterization, an increased emphasis has been placed on our involvement in flame code validation efforts. A functional combustor code should shorten and streamline future combustor design. Quantitative measurements of flow parameters such as temperature, species concentration, drop size and velocity using such methods as Raman and phase Doppler anemometry will provide data necessary in this effort.

  19. Towards novel compact laser sources for non-invasive diagnostics and treatment

    Science.gov (United States)

    Rafailov, Edik U.; Litvinova, Karina S.; Sokolovski, Sergei G.

    2015-08-01

    An important field of application of lasers is biomedical optics. Here, they offer great utility for diagnosis, therapy and surgery. For the development of novel methods of laser-based biomedical diagnostics careful study of light propagation in biological tissues is necessary to enhance our understanding of the optical measurements undertaken, increase research and development capacity and the diagnostic reliability of optical technologies. Ultimately, fulfilling these requirements will increase uptake in clinical applications of laser based diagnostics and therapeutics. To address these challenges informative biomarkers relevant to the biological and physiological function or disease state of the organism must be selected. These indicators are the results of the analysis of tissues and cells, such as blood. For non-invasive diagnostics peripheral blood, cells and tissue can potentially provide comprehensive information on the condition of the human organism. A detailed study of the light scattering and absorption characteristics can quickly detect physiological and morphological changes in the cells due to thermal, chemical, antibiotic treatments, etc [1-5]. The selection of a laser source to study the structure of biological particles also benefits from the fact that gross pathological changes are not induced and diagnostics make effective use of the monochromatic directional coherence properties of laser radiation.

  20. Reliable control using the primary and dual Youla parameterizations

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Stoustrup, J.

    2002-01-01

    Different aspects of modeling faults in dynamic systems are considered in connection with reliable control (RC). The fault models include models with additive faults, multiplicative faults and structural changes in the models due to faults in the systems. These descriptions are considered...... in connection with reliable control and feedback control with fault rejection. The main emphasis is on fault modeling. A number of fault diagnosis problems, reliable control problems, and feedback control with fault rejection problems are formulated/considered, again, mainly from a fault modeling point of view....... Reliability is introduced by means of the (primary) Youla parameterization of all stabilizing controllers, where an additional loop is closed around a diagnostic signal. In order to quantify the level of reliability, the dual Youla parameterization is introduced which can be used to analyze how large faults...

  1. Application of fuzzy-MOORA method: Ranking of components for reliability estimation of component-based software systems

    Directory of Open Access Journals (Sweden)

    Zeeshan Ali Siddiqui

    2016-01-01

    Full Text Available Component-based software system (CBSS development technique is an emerging discipline that promises to take software development into a new era. As hardware systems are presently being constructed from kits of parts, software systems may also be assembled from components. It is more reliable to reuse software than to create. It is the glue code and individual components reliability that contribute to the reliability of the overall system. Every component contributes to overall system reliability according to the number of times it is being used, some components are of critical usage, known as usage frequency of component. The usage frequency decides the weight of each component. According to their weights, each component contributes to the overall reliability of the system. Therefore, ranking of components may be obtained by analyzing their reliability impacts on overall application. In this paper, we propose the application of fuzzy multi-objective optimization on the basis of ratio analysis, Fuzzy-MOORA. The method helps us find the best suitable alternative, software component, from a set of available feasible alternatives named software components. It is an accurate and easy to understand tool for solving multi-criteria decision making problems that have imprecise and vague evaluation data. By the use of ratio analysis, the proposed method determines the most suitable alternative among all possible alternatives, and dimensionless measurement will realize the job of ranking of components for estimating CBSS reliability in a non-subjective way. Finally, three case studies are shown to illustrate the use of the proposed technique.

  2. Diagnostic imaging, a 'parallel' discipline. Can current technology provide a reliable digital diagnostic radiology department

    International Nuclear Information System (INIS)

    Moore, C.J.; Eddleston, B.

    1985-01-01

    Only recently has any detailed criticism been voiced about the practicalities of the introduction of generalised, digital, imaging complexes in diagnostic radiology. Although attendant technological problems are highlighted the authors argue that the fundamental causes of current difficulties are not in the generation but in the processing, filing and subsequent retrieval for display of digital image records. In the real world, looking at images is a parallel process of some complexity and so it is perhaps untimely to expect versatile handling of vast image data bases by existing computer hardware and software which, by their current nature, perform tasks serially. (author)

  3. Mechanical reliability assessment of optical fibres in Radiation environments

    International Nuclear Information System (INIS)

    Van Uffelen, M.

    2006-01-01

    After more than two decades of intensive research and even some pioneering applications in space, optical fibres are now finding their way in various radiation environments, including both fission and future fusion nuclear-power plants, and high-energy physics experiments. For example, next to distributed monitoring applications of large nuclear infrastructures, fibre-optics can also be used for data communications during maintenance operations in the reactor vessel of the future ITER (International Thermonuclear Experimental Reactor), or for plasma diagnostics applications during operation of the reactor. These maintenance and diagnostics tasks require the optical fibres to withstand extremely high doses of radiation, up to MGy dose levels and temperatures above 150 degrees Celsius. The reliability assessment of fibre-optic systems for their qualification in nuclear environments often requires to meet stringent radiation tolerance levels. The majority of (usually accelerated) radiation assessments have so far focused on optical properties, such as wavelength-dependent radiation induced attenuation and radio-luminescence. The relation of these radiation effects with the fabrication methods and other environmental parameters has been the subject of years of research. Only a few results are available on the long-term evolution of mechanical properties of irradiated optical fibres. As a first step towards understanding the long-term reliability of fibre-optic composite cables in hostile radiation environments, we therefore performed dynamic fatigue tests with different commercial-grade optical fibres, both multi-mode and single-mode types

  4. The Evaluation Method of the Lightning Strike on Transmission Lines Aiming at Power Grid Reliability

    Science.gov (United States)

    Wen, Jianfeng; Wu, Jianwei; Huang, Liandong; Geng, Yinan; Yu, zhanqing

    2018-01-01

    Lightning protection of power system focuses on reducing the flashover rate, only distinguishing by the voltage level, without considering the functional differences between the transmission lines, and being lack of analysis the effect on the reliability of power grid. This will lead lightning protection design of general transmission lines is surplus but insufficient for key lines. In order to solve this problem, the analysis method of lightning striking on transmission lines for power grid reliability is given. Full wave process theory is used to analyze the lightning back striking; the leader propagation model is used to describe the process of shielding failure of transmission lines. The index of power grid reliability is introduced and the effect of transmission line fault on the reliability of power system is discussed in detail.

  5. Current Human Reliability Analysis Methods Applied to Computerized Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring

    2012-06-01

    Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no US nuclear power plant has implemented CPs in its main control room (Fink et al., 2009). Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of enhanced ease of use and easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

  6. Experimental Investigation on Admittance-Based Piezoelectric Sensor Diagnostic Process

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Hyejin; Park, Tongil; Park, Gyuhae [Chonnam National University, Gwangju (Korea, Republic of)

    2015-01-15

    Structural health monitoring (SHM) techniques based on the use of active-sensing piezoelectric (PZT) materials have received considerable attention. The validation of the PZT functionality during SHM operation is critical to successfully implementing a reliable SHM system. In this study, we investigated several parameters that affect the admittance-based sensor diagnostic process. We experimentally identified the temperature dependency of the active-sensor diagnostic process. We found that the admittance-based sensor diagnostic process can differentiate the adhesion conditions of bonding materials that are used to install a PZT on a structure, which is important when designing a sensor diagnostic process for an SHM system.

  7. Efficient reliability analysis of structures with the rotational quasi-symmetric point- and the maximum entropy methods

    Science.gov (United States)

    Xu, Jun; Dang, Chao; Kong, Fan

    2017-10-01

    This paper presents a new method for efficient structural reliability analysis. In this method, a rotational quasi-symmetric point method (RQ-SPM) is proposed for evaluating the fractional moments of the performance function. Then, the derivation of the performance function's probability density function (PDF) is carried out based on the maximum entropy method in which constraints are specified in terms of fractional moments. In this regard, the probability of failure can be obtained by a simple integral over the performance function's PDF. Six examples, including a finite element-based reliability analysis and a dynamic system with strong nonlinearity, are used to illustrate the efficacy of the proposed method. All the computed results are compared with those by Monte Carlo simulation (MCS). It is found that the proposed method can provide very accurate results with low computational effort.

  8. INNOVATIVE METHODS TO EVALUATE THE RELIABILITY OF INFORMATION CONSOLIDATED FINANCIAL STATEMENTS

    Directory of Open Access Journals (Sweden)

    Irina P. Kurochkina

    2014-01-01

    Full Text Available The article explores the possibility of using foreign innovative methods to assess the reliabilityof information consolidated fi nancial statements of Russian companies. Recommendations aremade under their adaptation and applicationinto commercial organizations. Banish methodindicators are implemented in one of the world’s largest vertically integrated steel and miningcompanies. Audit firms are proposed to usemethods of assessing the reliability of information in the practical application of ISA.

  9. Competitive Protein-binding assay-based Enzyme-immunoassay Method, Compared to High-pressure Liquid Chromatography, Has a Very Lower Diagnostic Value to Detect Vitamin D Deficiency in 9–12 Years Children

    Science.gov (United States)

    Zahedi Rad, Maliheh; Neyestani, Tirang Reza; Nikooyeh, Bahareh; Shariatzadeh, Nastaran; Kalayi, Ali; Khalaji, Niloufar; Gharavi, Azam

    2015-01-01

    Background: The most reliable indicator of Vitamin D status is circulating concentration of 25-hydroxycalciferol (25(OH) D) routinely determined by enzyme-immunoassays (EIA) methods. This study was performed to compare commonly used competitive protein-binding assays (CPBA)-based EIA with the gold standard, high-pressure liquid chromatography (HPLC). Methods: Concentrations of 25(OH) D in sera from 257 randomly selected school children aged 9–11 years were determined by two methods of CPBA and HPLC. Results: Mean 25(OH) D concentration was 22 ± 18.8 and 21.9 ± 15.6 nmol/L by CPBA and HPLC, respectively. However, mean 25(OH) D concentrations of the two methods became different after excluding undetectable samples (25.1 ± 18.9 vs. 29 ± 14.5 nmol/L, respectively; P = 0.04). Based on predefined Vitamin D deficiency as 25(OH) D < 12.5 nmol/L, CPBA sensitivity and specificity were 44.2% and 60.6%, respectively, compared to HPLC. In receiver operating characteristic curve analysis, the best cut-offs for CPBA was 5.8 nmol/L, which gave 82% sensitivity, but specificity was 17%. Conclusions: Though CPBA may be used as a screening tool, more reliable methods are needed for diagnostic purposes. PMID:26330983

  10. Reliability and precision of stress sonography of the ulnar collateral ligament.

    Science.gov (United States)

    Bica, David; Armen, Joseph; Kulas, Anthony S; Youngs, Kevin; Womack, Zachary

    2015-03-01

    Musculoskeletal sonography has emerged as an additional diagnostic tool that can be used to assess medial elbow pain and laxity in overhead throwers. It provides a dynamic, rapid, and noninvasive modality in the evaluation of ligamentous structural integrity. Many studies have demonstrated the utility of dynamic sonography for medial elbow and ulnar collateral ligament (UCL) integrity. However, evaluating the reliabilityand precision of these measurements is critical if sonography is ultimately used as a clinical diagnostic tool. The purpose of this study was to evaluate the reliability and precision of stress sonography applied to the medial elbow. We conducted a cross-sectional study during the 2011 baseball off-season. Eighteen National Collegiate Athletic Association Division I pitchers were enrolled, and 36 elbows were studied. Using sonography, the medial elbow was assessed, and measurements of the UCL length and ulnohumeral joint gapping were performed twice under two conditions (unloaded and loaded) and bilaterally. Intraclass correlation coefficients (0.72-0.94) and standard errors of measurements (0.3-0.9 mm) for UCL length and ulnohumeral joint gapping were good to excellent. Mean differences between unloaded and loaded conditions for the dominant arms were 1.3 mm (gapping; P < .001) and 1.4 mm (UCL length; P < .001). Medial elbow stress sonography is a reliable and precise method for detecting changes in ulnohumeral joint gapping and UCL lengthening. Ultimately, this method may provide clinicians valuable information regarding the medial elbow's response to valgus loading and may help guide treatment options. © 2015 by the American Institute of Ultrasound in Medicine.

  11. Reliability Analysis of a Composite Wind Turbine Blade Section Using the Model Correction Factor Method: Numerical Study and Validation

    DEFF Research Database (Denmark)

    Dimitrov, Nikolay Krasimirov; Friis-Hansen, Peter; Berggreen, Christian

    2013-01-01

    by the composite failure criteria. Each failure mode has been considered in a separate component reliability analysis, followed by a system analysis which gives the total probability of failure of the structure. The Model Correction Factor method used in connection with FORM (First-Order Reliability Method) proved...

  12. Reliability of an experimental method to analyse the impact point on a golf ball during putting.

    Science.gov (United States)

    Richardson, Ashley K; Mitchell, Andrew C S; Hughes, Gerwyn

    2015-06-01

    This study aimed to examine the reliability of an experimental method identifying the location of the impact point on a golf ball during putting. Forty trials were completed using a mechanical putting robot set to reproduce a putt of 3.2 m, with four different putter-ball combinations. After locating the centre of the dimple pattern (centroid) the following variables were tested; distance of the impact point from the centroid, angle of the impact point from the centroid and distance of the impact point from the centroid derived from the X, Y coordinates. Good to excellent reliability was demonstrated in all impact variables reflected in very strong relative (ICC = 0.98-1.00) and absolute reliability (SEM% = 0.9-4.3%). The highest SEM% observed was 7% for the angle of the impact point from the centroid. In conclusion, the experimental method was shown to be reliable at locating the centroid location of a golf ball, therefore allowing for the identification of the point of impact with the putter head and is suitable for use in subsequent studies.

  13. Cable Diagnostic Focused Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  14. Corpuscular plasma diagnostics

    International Nuclear Information System (INIS)

    Afrosimov, V.; Petrov, M.

    1984-01-01

    An elementary explanation is presented of the physical principles and important methods of corpuscular plasma diagnostics. The invaluable role of corpuscular methods for measuring the hot plasma ion component in thermonuclear facilities, especially hydrogen ions in tokamaks, is emphasized. All corpuscular methods employ analysis of fast neutral atoms and therefore the mechanism of their creation inside a hot plasma is explained first. The ammount of information obtainable from spectra of fast neutrals is discussed. Multichannel analyzers developed at the FTI A.F. Ioffe in Leningrad are described in detail. Classical passive corpuscular diagnostics are examined as are active methods using artifitial beams of hydrogen atoms. The method used for obtaining local values of ion temperature and density is explained. Corpuscular spectroscopic diagnostics and its application for measuring impurities is mentioned. (J.U.)

  15. Working Group summary reports from the Advanced Photon Source reliability workshop

    International Nuclear Information System (INIS)

    1992-05-01

    A workshop was held at APS to address reliability goals for accelerator systems. Seventy-one individuals participated in the workshop, including 30 from other institutions. The goals of the workshop were to: (1) Give attendees an introduction to the basic concepts of reliability analysis. (2) Exchange information on operating experience at existing accelerator facilities and strategies for achieving reliability at facilities under design or in construction. (3) Discuss reliability goals for APS and the means of their achievement. This report contains the working group summary report an APS's following systems: RF Systems; Power Supplies; Magnet Systems; Interlock and Diagnostics; and Vacuum Systems

  16. Application of the spectral-correlation method for diagnostics of cellulose paper

    Science.gov (United States)

    Kiesewetter, D.; Malyugin, V.; Reznik, A.; Yudin, A.; Zhuravleva, N.

    2017-11-01

    The spectral-correlation method was described for diagnostics of optically inhomogeneous biological objects and materials of natural origin. The interrelation between parameters of the studied objects and parameters of the cross correlation function of speckle patterns produced by scattering of coherent light at different wavelengths is shown for thickness, optical density and internal structure of the material. A detailed study was performed for cellulose electric insulating paper with different parameters.

  17. Use of the virtual instrument technology in complex diagnostics of marine electrical equipment

    Directory of Open Access Journals (Sweden)

    Ivlev M. L.

    2017-12-01

    Full Text Available The assessment of the most informative methods of diagnostics of mechanisms with electric drive has been given; their realization in a measuring complex on the basis of the virtual device has been considered. The comparative analysis of vibration methods for the analysis of current spectra and the thermal method of nondestructive testing has been carried out. It has been stated that methods of vibration diagnostics are more sensitive to defects in the mechanical part of the electric drive (determination of defects in bearing assemblies, misalignment of shafts, imbalance of rotating parts. Analysis of the current spectrum at the early stage has shown the defects of rotor windings, static and dynamic rotor eccentricity. The temperature of the bearing assemblies and the stator (the thermal control method indicates the defects in lubrication and cooling systems. The set of methods of nondestructive control allows increase the completeness and reliability of diagnosis of the mechanism with electric drive. The optimal solution to realize into one measuring instrument all methods of diagnostics is to use the technology of virtual instruments. The list of components for the measuring part of the complex and the functional scheme of the program for processing the results have been given. Spectra of vibration of defective mechanisms have been obtained with the help of the measuring complex based on the virtual instrument. Some recommendations have been given on the introduction of the virtual appliance in the State register of measuring instruments.

  18. Advance in study of intelligent diagnostic method for nuclear power plant

    International Nuclear Information System (INIS)

    Zhou Gang; Yang Li

    2008-01-01

    The advance of research on the application of three types of intelligent diagnostic approach based on neural network (ANN), fuzzy logic and expert system to the operation status monitoring and fault diagnosis of nuclear power plant (NPP) was reviewed. The research status and characters on status monitoring and fault diagnosis approaches based on neural network, fuzzy logic and expert system for nuclear power plant were analyzed. The development trend of applied research on intelligent diagnostic approaches for nuclear power plant was explored. The analysis results show that the research achievements on intelligent diagnostic approaches based on fuzzy logic and expert system for nuclear power plant are not much relatively. The research of intelligent diagnostic approaches for nuclear power plant concentrate on the aspect of operation status monitoring and fault diagnosis based on neural networks for nuclear power plant. The advancing tendency of intelligent diagnostic approaches for nuclear power plant is the combination of various intelligent diagnostic approaches, the combination of neural network diagnostic approaches and other diagnostic approaches as well as multiple neural network diagnostic approaches. (authors)

  19. [Parenting stress and the reliability of parental information in the diagnostics of children and adolescents with symptoms of psychiatric and behavioral disorders].

    Science.gov (United States)

    Irlbauer-Müller, Viktoria; Eichler, Anna; Stemmler, Mark; Moll, Gunther H; Kratz, Oliver

    2017-07-01

    Information from parents is regularly used in the diagnostic process of children and adolescents with psychiatric symptoms. But the reliability of this information is debatable, because the parents’ own stress can distort their perceptions of the child’s symptoms. For each of N = 68 children and adolescents (11–18 years) who were using mental health services for the first time, we evaluated the ratings of a parent and a professional clinician (internalizing, externalizing symptoms, total-problem score). In addition, parenting stress was scored on the Eltern-Belastungs-Inventars (EBI, Tröster, 2011), which measures both child-related stress and parent-related stress as well as total stress. Highly stressed parent ratings differed more from the clinicians’ ratings than the ratings of less stressed parents. Additionally, correlations showed that higher parenting stress resulted in larger differences between the parent’s and the clinician’s assessments. Multiple regressions proved the predictive value of child-caused parenting stress for these differences. These results apply for internalizing symptoms, externalizing symptoms, and total-problem score. Parenting stress should be evaluated systematically in order to carefully assess the value of the information from parents and to determine how it should be included in diagnostic and therapeutical decisions.

  20. Efficient Estimation of Extreme Non-linear Roll Motions using the First-order Reliability Method (FORM)

    DEFF Research Database (Denmark)

    Jensen, Jørgen Juncher

    2007-01-01

    In on-board decision support systems efficient procedures are needed for real-time estimation of the maximum ship responses to be expected within the next few hours, given on-line information on the sea state and user defined ranges of possible headings and speeds. For linear responses standard...... frequency domain methods can be applied. To non-linear responses like the roll motion, standard methods like direct time domain simulations are not feasible due to the required computational time. However, the statistical distribution of non-linear ship responses can be estimated very accurately using...... the first-order reliability method (FORM), well-known from structural reliability problems. To illustrate the proposed procedure, the roll motion is modelled by a simplified non-linear procedure taking into account non-linear hydrodynamic damping, time-varying restoring and wave excitation moments...

  1. Some aspects of diagnostic systems perspective

    International Nuclear Information System (INIS)

    Korosec, D.

    1998-01-01

    The integrity and safety of all nuclear power plant systems and components is guaranteed by the high requirements to quality assurance during all phases of design, fabrication, construction and operation. Many of the countries operating nuclear facilities, introduced advanced, sophisticated diagnostic systems for continuous monitoring safety important process parameters. The licensee should perform an assessment of the existing diagnostic systems, often supplied by the original design, their reliability and the need for the introduction of the additional monitoring/diagnostic systems. The operating experience should be taken into account and the assessment of the further needs. On this field has to be made on the results of PSA studies. In addition to the cost benefit analysis the evaluation of the new diagnostic systems in the light of nuclear safety should be also made. Experience, gained from the utilities, which have already installed this kind of the equipment should be very useful. Introducing new diagnostic systems will require often a safety assessment of the necessary modifications. Licensing process should be based on the existing nuclear legislation with certain additional requirements. (author)

  2. Online diagnostics of time-resolved electron beam properties with femtosecond resolution for X-ray FELs

    International Nuclear Information System (INIS)

    Yan, Minjie

    2016-07-01

    The European X-ray Free-electron Laser (XFEL) puts high demands on the quality of the highbrightness driving electron beam with bunch lengths in the femtosecond regime. Longitudinal diagnostics is requested to optimize and control the longitudinal profile, the longitudinal phase space, the slice energy spread and the slice emittance of the electron bunch, all of which are crucial to the generation of Self-Amplified Spontaneous Emission (SASE). The high bunch repetition rate of the super-conducting accelerator renders diagnostic method that is (quasi) non-destructive to the generation of SASE possible. In this thesis, three online diagnostic sections utilizing transverse deflecting structures (TDS) have been designed for the European XFEL, providing access to all parameters of interest with a longitudinal resolution down to below 10 fs.The requirement on the non-destructive capability has been realized by the implementation of fast kickermagnets and off-axis screens, which has been validated experimentally using an installation of the same concept at the Free-electron Laser in Hamburg. A special slicing procedure has been developed to significantly enhance the accuracy of slice energy spread measurements. Suppression of coherence effects, which impede the beam imaging in the TDS diagnostics, has been first demonstrated experimentally using the spatial separation method with scintillator screens. Comparison of the results of emittance measurements using the quadrupole scan method with those using the multi-screen method has proved the reliability of the latter method, which has been modelled intensively for the European XFEL.

  3. Application of the Systematic Sensor Selection Strategy for Turbofan Engine Diagnostics

    Science.gov (United States)

    Sowers, T. Shane; Kopasakis, George; Simon, Donald L.

    2008-01-01

    The data acquired from available system sensors forms the foundation upon which any health management system is based, and the available sensor suite directly impacts the overall diagnostic performance that can be achieved. While additional sensors may provide improved fault diagnostic performance, there are other factors that also need to be considered such as instrumentation cost, weight, and reliability. A systematic sensor selection approach is desired to perform sensor selection from a holistic system-level perspective as opposed to performing decisions in an ad hoc or heuristic fashion. The Systematic Sensor Selection Strategy is a methodology that optimally selects a sensor suite from a pool of sensors based on the system fault diagnostic approach, with the ability of taking cost, weight, and reliability into consideration. This procedure was applied to a large commercial turbofan engine simulation. In this initial study, sensor suites tailored for improved diagnostic performance are constructed from a prescribed collection of candidate sensors. The diagnostic performance of the best performing sensor suites in terms of fault detection and identification are demonstrated, with a discussion of the results and implications for future research.

  4. A Reliable Method to Measure Lip Height Using Photogrammetry in Unilateral Cleft Lip Patients.

    Science.gov (United States)

    van der Zeeuw, Frederique; Murabit, Amera; Volcano, Johnny; Torensma, Bart; Patel, Brijesh; Hay, Norman; Thorburn, Guy; Morris, Paul; Sommerlad, Brian; Gnarra, Maria; van der Horst, Chantal; Kangesu, Loshan

    2015-09-01

    There is still no reliable tool to determine the outcome of the repaired unilateral cleft lip (UCL). The aim of this study was therefore to develop an accurate, reliable tool to measure vertical lip height from photographs. The authors measured the vertical height of the cutaneous and vermilion parts of the lip in 72 anterior-posterior view photographs of 17 patients with repairs to a UCL. Points on the lip's white roll and vermillion were marked on both the cleft and the noncleft sides on each image. Two new concepts were tested. First, photographs were standardized using the horizontal (medial to lateral) eye fissure width (EFW) for calibration. Second, the authors tested the interpupillary line (IPL) and the alar base line (ABL) for their reliability as horizontal lines of reference. Measurements were taken by 2 independent researchers, at 2 different time points each. Overall 2304 data points were obtained and analyzed. Results showed that the method was very effective in measuring the height of the lip on the cleft side with the noncleft side. When using the IPL, inter- and intra-rater reliability was 0.99 to 1.0, with the ABL it varied from 0.91 to 0.99 with one exception at 0.84. The IPL was easier to define because in some subjects the overhanging nasal tip obscured the alar base and gave more consistent measurements possibly because the reconstructed alar base was sometimes indistinct. However, measurements from the IPL can only give the percentage difference between the left and right sides of the lip, whereas those from the ABL can also give exact measurements. Patient examples were given that show how the measurements correlate with clinical assessment. The authors propose this method of photogrammetry with the innovative use of the IPL as a reliable horizontal plane and use of the EFW for calibration as a useful and reliable tool to assess the outcome of UCL repair.

  5. Cross-diagnostic validity of the Nottingham health profile index of distress (NHPD

    Directory of Open Access Journals (Sweden)

    Klevsgård Rosemarie

    2008-07-01

    Full Text Available Abstract Background The Nottingham Health Profile index of Distress (NHPD has been proposed as a generic undimensional 24-item measure of illness-related distress that is embedded in the Nottingham Health Profile (NHP. Data indicate that the NHPD may have psychometric advantages to the 6-dimensional NHP profile scores. Detailed psychometric evaluations are, however, lacking. Furthermore, to support the validity of the generic property of outcome measures evidence that scores can be interpreted in the same manner in different diagnostic groups are needed. It is currently unknown if NHPD scores have the same meaning across patient populations. This study evaluated the measurement properties and cross-diagnostic validity of the NHPD as a survey instrument among people with Parkinson's disease (PD and peripheral arterial disease (PAD. Methods Data from 215 (PD and 258 (PAD people were Rasch analyzed regarding model fit, reliability, differential item functioning (DIF, unidimensionality and targeting. In cases of cross-diagnostic DIF this was adjusted for and the impact of DIF on the total score and person measures was assessed. Results The NHPD was found to have good overall and individual item fit in both disorders as well as in the pooled sample, but seven items displayed signs of cross-diagnostic DIF. Following adjustment for DIF some aspects of model fit were slightly compromised, whereas others improved somewhat. DIF did not impact total NHPD scores or resulting person measures, but the unadjusted scale displayed minor signs of multidimensionality. Reliability was > 0.8 in all within- and cross-diagnostic analyses. Items tended to represent more distress (mean, 0 logits than that experienced by the sample (mean, -1.6 logits. Conclusion This study supports the within- and cross-diagnostic validity of the NHPD as a survey tool among people with PD and PAD. We encourage others to reassess available NHP data within the NHPD framework to further

  6. A two-step method for fast and reliable EUV mask metrology

    Science.gov (United States)

    Helfenstein, Patrick; Mochi, Iacopo; Rajendran, Rajeev; Yoshitake, Shusuke; Ekinci, Yasin

    2017-03-01

    One of the major obstacles towards the implementation of extreme ultraviolet lithography for upcoming technology nodes in semiconductor industry remains the realization of a fast and reliable detection methods patterned mask defects. We are developing a reflective EUV mask-scanning lensless imaging tool (RESCAN), installed at the Swiss Light Source synchrotron at the Paul Scherrer Institut. Our system is based on a two-step defect inspection method. In the first step, a low-resolution defect map is generated by die to die comparison of the diffraction patterns from areas with programmed defects, to those from areas that are known to be defect-free on our test sample. In a later stage, a die to database comparison will be implemented in which the measured diffraction patterns will be compared to those calculated directly from the mask layout. This Scattering Scanning Contrast Microscopy technique operates purely in the Fourier domain without the need to obtain the aerial image and, given a sufficient signal to noise ratio, defects are found in a fast and reliable way, albeit with a location accuracy limited by the spot size of the incident illumination. Having thus identified rough locations for the defects, a fine scan is carried out in the vicinity of these locations. Since our source delivers coherent illumination, we can use an iterative phase-retrieval method to reconstruct the aerial image of the scanned area with - in principle - diffraction-limited resolution without the need of an objective lens. Here, we will focus on the aerial image reconstruction technique and give a few examples to illustrate the capability of the method.

  7. Qualitative Evaluation of Digital Hand X-rays is Not a Reliable Method to Assess Bone Mineral Density

    Directory of Open Access Journals (Sweden)

    AndrewJ. Miller

    2017-01-01

    Full Text Available Object: The gold standard for evaluating bone mineral density is dual energy x-ray absorptiometry (DEXA.  Prior studies have shown poor reliability using analog wrist X-rays in diagnosing osteoporosis. Our goal was to investigate if there was improved diagnostic value to visual assessment of digital hand X-rays in osteoporosis screening. We hypothesized that similar to analog counterparts, digital hand X-rays have poor correlation and reliability in determining bone mineral density (BMD relative to DEXA.Methods: We prospectively evaluated female patients older than 65 years who presented to our hand clinic with digital hand and wrist X-rays as part of their evaluation over six months. Patients who had a fracture and were without DEXA scans within the past two years were excluded. Five fellowship-trained hand surgeons, blinded to DEXA T-scores, evaluated the x-rays over two assessments separated by four weeks and classified them as osteoporotic, osteopenic, or normal BMD.  Accuracy relative to DEXA T-score, interobserver and intraobserver rates were calculated.Results: Thirty four patients met the inclusion criteria and a total of 340 x-rays reviews were performed.  The assessments were correct in 169 cases (49% as compared to the DEXA T-scores. A mean weighted kappa coefficient of agreement between observers was 0.29 (range 0.02-0.41 reflecting a fair agreement. The first and second assessment for all five physicians was 0.46 (range 0.19-0.78 reflecting a moderate agreement.  Grouping osteoporosis and osteopenia together compared to normal, the accuracy, interobserver and intraobserver rates increased to 63%, 0.42 and 0.54 respectively.Conclusion: Abnormally low BMD is a common occurrence in patients treated for upper extremity disorders. There is poor accuracy relative to DEXA scan and only fair agreement in diagnosing osteoporosis using visual assessments of digital x-rays.

  8. A rapid reliability estimation method for directed acyclic lifeline networks with statistically dependent components

    International Nuclear Information System (INIS)

    Kang, Won-Hee; Kliese, Alyce

    2014-01-01

    Lifeline networks, such as transportation, water supply, sewers, telecommunications, and electrical and gas networks, are essential elements for the economic and societal functions of urban areas, but their components are highly susceptible to natural or man-made hazards. In this context, it is essential to provide effective pre-disaster hazard mitigation strategies and prompt post-disaster risk management efforts based on rapid system reliability assessment. This paper proposes a rapid reliability estimation method for node-pair connectivity analysis of lifeline networks especially when the network components are statistically correlated. Recursive procedures are proposed to compound all network nodes until they become a single super node representing the connectivity between the origin and destination nodes. The proposed method is applied to numerical network examples and benchmark interconnected power and water networks in Memphis, Shelby County. The connectivity analysis results show the proposed method's reasonable accuracy and remarkable efficiency as compared to the Monte Carlo simulations

  9. Accuracy and Reliability of the Klales et al. (2012) Morphoscopic Pelvic Sexing Method.

    Science.gov (United States)

    Lesciotto, Kate M; Doershuk, Lily J

    2018-01-01

    Klales et al. (2012) devised an ordinal scoring system for the morphoscopic pelvic traits described by Phenice (1969) and used for sex estimation of skeletal remains. The aim of this study was to test the accuracy and reliability of the Klales method using a large sample from the Hamann-Todd collection (n = 279). Two observers were blinded to sex, ancestry, and age and used the Klales et al. method to estimate the sex of each individual. Sex was correctly estimated for females with over 95% accuracy; however, the male allocation accuracy was approximately 50%. Weighted Cohen's kappa and intraclass correlation coefficient analysis for evaluating intra- and interobserver error showed moderate to substantial agreement for all traits. Although each trait can be reliably scored using the Klales method, low accuracy rates and high sex bias indicate better trait descriptions and visual guides are necessary to more accurately reflect the range of morphological variation. © 2017 American Academy of Forensic Sciences.

  10. Developmentally sensitive diagnostic criteria for mental health disorders in early childhood: the diagnostic and statistical manual of mental disorders-IV, the research diagnostic criteria-preschool age, and the diagnostic classification of mental health and developmental disorders of infancy and early childhood-revised.

    Science.gov (United States)

    Egger, Helen L; Emde, Robert N

    2011-01-01

    As the infant mental health field has turned its focus to the presentation, course, and treatment of clinically significant mental health disorders, the need for reliable and valid criteria for identifying and assessing mental health symptoms and disorders in early childhood has become urgent. In this article we offer a critical perspective on diagnostic classification of mental health disorders in young children. We place the issue of early childhood diagnosis within the context of classification of psychopathology at other ages and describe, in some detail, diagnostic classifications that have been developed specifically for young children, including the Diagnostic Classification of Mental Health and Developmental Disorders of Infancy and Early Childhood (DC:0-3R; ZERO TO THREE, 2005), a diagnostic classification for mental health symptoms and disorders in infants, toddlers, and preschoolers. We briefly outline the role of diagnostic classification in clinical assessment and treatment planning. Last, we review the limitations of current approaches to the diagnostic classification of mental health disorders in young children. PsycINFO Database Record (c) 2010 APA, all rights reserved.

  11. Inverse Reliability Task: Artificial Neural Networks and Reliability-Based Optimization Approaches

    OpenAIRE

    Lehký , David; Slowik , Ondřej; Novák , Drahomír

    2014-01-01

    Part 7: Genetic Algorithms; International audience; The paper presents two alternative approaches to solve inverse reliability task – to determine the design parameters to achieve desired target reliabilities. The first approach is based on utilization of artificial neural networks and small-sample simulation Latin hypercube sampling. The second approach considers inverse reliability task as reliability-based optimization task using double-loop method and also small-sample simulation. Efficie...

  12. Reliability of software

    International Nuclear Information System (INIS)

    Kopetz, H.

    1980-01-01

    Common factors and differences in the reliability of hardware and software; reliability increase by means of methods of software redundancy. Maintenance of software for long term operating behavior. (HP) [de

  13. Reliability design of a critical facility: An application of PRA methods

    International Nuclear Information System (INIS)

    Souza Vieira Neto, A.; Souza Borges, W. de

    1987-01-01

    Although a general agreement concerning the enforcement of reliability (probabilistic) design criteria for nuclear utilities is yet to be achieved. PRA methodology can still be used successfully as a project design and review tool, aimed at improving system's prospective performance or minimizing expected accident consequences. In this paper, the potential of such an application of PRA methods is examined in the special case of a critical design project currently being developed in Brazil. (orig.)

  14. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods, Stage 18

    International Nuclear Information System (INIS)

    Pazsit, Imre; Nam, Tran Hoai; Dykin, Victor; Jonsson, Anders

    2013-01-01

    This report constitutes Stage 18 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The objective of the research program is to contribute to the strategic research goal of competence and research capacity by building up competence within the Department of Nuclear Engineering at Chalmers University of Technology, regarding reactor physics, reactor dynamics and noise diagnostics. The purpose is also to contribute to the research goal of giving a basis for SSM's supervision by developing methods for identification and localization of perturbations in reactor cores. Results up to Stage 17 were reported in SKI and SSM reports, as listed in the report's summary

  15. Improvement of human reliability analysis method for PRA

    International Nuclear Information System (INIS)

    Tanji, Junichi; Fujimoto, Haruo

    2013-09-01

    It is required to refine human reliability analysis (HRA) method by, for example, incorporating consideration for the cognitive process of operator into the evaluation of diagnosis errors and decision-making errors, as a part of the development and improvement of methods used in probabilistic risk assessments (PRAs). JNES has been developed a HRA method based on ATHENA which is suitable to handle the structured relationship among diagnosis errors, decision-making errors and operator cognition process. This report summarizes outcomes obtained from the improvement of HRA method, in which enhancement to evaluate how the plant degraded condition affects operator cognitive process and to evaluate human error probabilities (HEPs) which correspond to the contents of operator tasks is made. In addition, this report describes the results of case studies on the representative accident sequences to investigate the applicability of HRA method developed. HEPs of the same accident sequences are also estimated using THERP method, which is most popularly used HRA method, and comparisons of the results obtained using these two methods are made to depict the differences of these methods and issues to be solved. Important conclusions obtained are as follows: (1) Improvement of HRA method using operator cognitive action model. Clarification of factors to be considered in the evaluation of human errors, incorporation of degraded plant safety condition into HRA and investigation of HEPs which are affected by the contents of operator tasks were made to improve the HRA method which can integrate operator cognitive action model into ATHENA method. In addition, the detail of procedures of the improved method was delineated in the form of flowchart. (2) Case studies and comparison with the results evaluated by THERP method. Four operator actions modeled in the PRAs of representative BWR5 and 4-loop PWR plants were selected and evaluated as case studies. These cases were also evaluated using

  16. Non-invasive biomedical research and diagnostics enabled by innovative compact lasers

    Science.gov (United States)

    Litvinova, Karina S.; Rafailov, Ilya E.; Dunaev, Andrey V.; Sokolovski, Sergei G.; Rafailov, Edik U.

    2017-11-01

    For over half a century, laser technology has undergone a technological revolution. These technologies, particularly semiconductor lasers, are employed in a myriad of fields. Optical medical diagnostics, one of the emerging areas of laser application, are on the forefront of application around the world. Optical methods of non- or minimally invasive bio-tissue investigation offer significant advantages over alternative methods, including rapid real-time measurement, non-invasiveness and high resolution (guaranteeing the safety of a patient). These advantages demonstrate the growing success of such techniques. In this review, we will outline the recent status of laser technology applied in the biomedical field, focusing on the various available approaches, particularly utilising compact semiconductor lasers. We will further consider the advancement and integration of several complimentary biophotonic techniques into single multimodal devices, the potential impact of such devices and their future applications. Based on our own studies, we will also cover the simultaneous collection of physiological data with the aid a multifunctional diagnostics system, concentrating on the optimisation of the new technology towards a clinical application. Such data is invaluable for developing algorithms capable of delivering consistent, reliable and meaningful diagnostic information, which can ultimately be employed for the early diagnosis of disease conditions in individuals from around the world.

  17. Decreased Diagnostic Accuracy of Multislice Coronary Computed Tomographic Angiography in Women with Atypical Angina Symptoms

    Directory of Open Access Journals (Sweden)

    Wen-Ying Jin

    2016-01-01

    Conclusions: Although MSCT is a reliable diagnostic modality for the exclusion of significant coronary artery stenoses in all patients, gender and atypical symptoms might have some influence on its diagnostic accuracy.

  18. A methodology to incorporate organizational factors into human reliability analysis

    International Nuclear Information System (INIS)

    Li Pengcheng; Chen Guohua; Zhang Li; Xiao Dongsheng

    2010-01-01

    A new holistic methodology for Human Reliability Analysis (HRA) is proposed to model the effects of the organizational factors on the human reliability. Firstly, a conceptual framework is built, which is used to analyze the causal relationships between the organizational factors and human reliability. Then, the inference model for Human Reliability Analysis is built by combining the conceptual framework with Bayesian networks, which is used to execute the causal inference and diagnostic inference of human reliability. Finally, a case example is presented to demonstrate the specific application of the proposed methodology. The results show that the proposed methodology of combining the conceptual model with Bayesian Networks can not only easily model the causal relationship between organizational factors and human reliability, but in a given context, people can quantitatively measure the human operational reliability, and identify the most likely root causes or the prioritization of root causes caused human error. (authors)

  19. Methods of Helminthiasis Diagnosis at the Present Stage

    Directory of Open Access Journals (Sweden)

    I.B. Yershova

    2014-04-01

    Full Text Available The article describes the methods of diagnosis of helminth infestations: microscopic, immunoenzyme analysis, serology, polymerase chain reaction, bioresonance diagnostics, haemoscanning, as well as instrumental methods (ultrasound and X-ray examination, computed tomography and laboratory analysis of indirect value (complete blood count, liver function tests, fecal dysbiosis. Advantages of methods, as well as disadvantages, the reliability of the findings are described. Questionnaire for patients are offered to determine the risk of helminth infestation.

  20. Between-day reliability of a method for non-invasive estimation of muscle composition.

    Science.gov (United States)

    Simunič, Boštjan

    2012-08-01

    Tensiomyography is a method for valid and non-invasive estimation of skeletal muscle fibre type composition. The validity of selected temporal tensiomyographic measures has been well established recently; there is, however, no evidence regarding the method's between-day reliability. Therefore it is the aim of this paper to establish the between-day repeatability of tensiomyographic measures in three skeletal muscles. For three consecutive days, 10 healthy male volunteers (mean±SD: age 24.6 ± 3.0 years; height 177.9 ± 3.9 cm; weight 72.4 ± 5.2 kg) were examined in a supine position. Four temporal measures (delay, contraction, sustain, and half-relaxation time) and maximal amplitude were extracted from the displacement-time tensiomyogram. A reliability analysis was performed with calculations of bias, random error, coefficient of variation (CV), standard error of measurement, and intra-class correlation coefficient (ICC) with a 95% confidence interval. An analysis of ICC demonstrated excellent agreement (ICC were over 0.94 in 14 out of 15 tested parameters). However, lower CV was observed in half-relaxation time, presumably because of the specifics of the parameter definition itself. These data indicate that for the three muscles tested, tensiomyographic measurements were reproducible across consecutive test days. Furthermore, we indicated the most possible origin of the lowest reliability detected in half-relaxation time. Copyright © 2012 Elsevier Ltd. All rights reserved.