WorldWideScience

Sample records for reliability test results

  1. Reliability Estimation Based Upon Test Plan Results

    National Research Council Canada - National Science Library

    Read, Robert

    1997-01-01

    The report contains a brief summary of aspects of the Maximus reliability point and interval estimation technique as it has been applied to the reliability of a device whose surveillance tests contain...

  2. Prediction of safety critical software operational reliability from test reliability using testing environment factors

    International Nuclear Information System (INIS)

    Jung, Hoan Sung; Seong, Poong Hyun

    1999-01-01

    It has been a critical issue to predict the safety critical software reliability in nuclear engineering area. For many years, many researches have focused on the quantification of software reliability and there have been many models developed to quantify software reliability. Most software reliability models estimate the reliability with the failure data collected during the test assuming that the test environments well represent the operation profile. User's interest is however on the operational reliability rather than on the test reliability. The experiences show that the operational reliability is higher than the test reliability. With the assumption that the difference in reliability results from the change of environment, from testing to operation, testing environment factors comprising the aging factor and the coverage factor are developed in this paper and used to predict the ultimate operational reliability with the failure data in testing phase. It is by incorporating test environments applied beyond the operational profile into testing environment factors. The application results show that the proposed method can estimate the operational reliability accurately. (Author). 14 refs., 1 tab., 1 fig

  3. Proof tests on reliability

    International Nuclear Information System (INIS)

    Mishima, Yoshitsugu

    1983-01-01

    In order to obtain public understanding on nuclear power plants, tests should be carried out to prove the reliability and safety of present LWR plants. For example, the aseismicity of nuclear power plants must be verified by using a large scale earthquake simulator. Reliability test began in fiscal 1975, and the proof tests on steam generators and on PWR support and flexure pins against stress corrosion cracking have already been completed, and the results have been internationally highly appreciated. The capacity factor of the nuclear power plant operation in Japan rose to 80% in the summer of 1983, and considering the period of regular inspection, it means the operation of almost full capacity. Japanese LWR technology has now risen to the top place in the world after having overcome the defects. The significance of the reliability test is to secure the functioning till the age limit is reached, to confirm the correct forecast of deteriorating process, to confirm the effectiveness of the remedy to defects and to confirm the accuracy of predicting the behavior of facilities. The reliability of nuclear valves, fuel assemblies, the heat affected zones in welding, reactor cooling pumps and electric instruments has been tested or is being tested. (Kako, I.)

  4. Test Reliability at the Individual Level

    Science.gov (United States)

    Hu, Yueqin; Nesselroade, John R.; Erbacher, Monica K.; Boker, Steven M.; Burt, S. Alexandra; Keel, Pamela K.; Neale, Michael C.; Sisk, Cheryl L.; Klump, Kelly

    2016-01-01

    Reliability has a long history as one of the key psychometric properties of a test. However, a given test might not measure people equally reliably. Test scores from some individuals may have considerably greater error than others. This study proposed two approaches using intraindividual variation to estimate test reliability for each person. A simulation study suggested that the parallel tests approach and the structural equation modeling approach recovered the simulated reliability coefficients. Then in an empirical study, where forty-five females were measured daily on the Positive and Negative Affect Schedule (PANAS) for 45 consecutive days, separate estimates of reliability were generated for each person. Results showed that reliability estimates of the PANAS varied substantially from person to person. The methods provided in this article apply to tests measuring changeable attributes and require repeated measures across time on each individual. This article also provides a set of parallel forms of PANAS. PMID:28936107

  5. Test results of reliable and very high capillary multi-evaporators / condenser loop

    Energy Technology Data Exchange (ETDEWEB)

    Van Oost, S; Dubois, M; Bekaert, G [Societe Anonyme Belge de Construction Aeronautique - SABCA (Belgium)

    1997-12-31

    The paper present the results of various SABCA activities in the field of two-phase heat transport system. These results have been based on a critical review and analysis of the existing two-phase loop and of the future loop needs in space applications. The research and the development of a high capillary wick (capillary pressure up to 38 000 Pa) are described. These activities have led towards the development of a reliable high performance capillary loop concept (HPCPL), which is discussed in details. Several loop configurations mono/multi-evaporators have been ground tested. The presented results of various tests clearly show the viability of this concept for future applications. Proposed flight demonstrations as well as potential applications conclude this paper. (authors) 7 refs.

  6. Test results of reliable and very high capillary multi-evaporators / condenser loop

    Energy Technology Data Exchange (ETDEWEB)

    Van Oost, S.; Dubois, M.; Bekaert, G. [Societe Anonyme Belge de Construction Aeronautique - SABCA (Belgium)

    1996-12-31

    The paper present the results of various SABCA activities in the field of two-phase heat transport system. These results have been based on a critical review and analysis of the existing two-phase loop and of the future loop needs in space applications. The research and the development of a high capillary wick (capillary pressure up to 38 000 Pa) are described. These activities have led towards the development of a reliable high performance capillary loop concept (HPCPL), which is discussed in details. Several loop configurations mono/multi-evaporators have been ground tested. The presented results of various tests clearly show the viability of this concept for future applications. Proposed flight demonstrations as well as potential applications conclude this paper. (authors) 7 refs.

  7. Test-re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females.

    Science.gov (United States)

    Beardsley, Chris; Egerton, Tim; Skinner, Brendon

    2016-01-01

    Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.

  8. Prediction of software operational reliability using testing environment factors

    International Nuclear Information System (INIS)

    Jung, Hoan Sung; Seong, Poong Hyun

    1995-01-01

    For many years, many researches have focused on the quantification of software reliability and there are many models developed to quantify software reliability. Most software reliability models estimate the reliability with the failure data collected during the test assuming that the test environments well represent the operation profile. The experiences show that the operational reliability is higher than the test reliability User's interest is on the operational reliability rather than on the test reliability, however. With the assumption that the difference in reliability results from the change of environment, testing environment factors comprising the aging factor and the coverage factor are defined in this study to predict the ultimate operational reliability with the failure data. It is by incorporating test environments applied beyond the operational profile into testing environment factors. The application results are close to the actual data

  9. Test-retest reliability of cognitive EEG

    Science.gov (United States)

    McEvoy, L. K.; Smith, M. E.; Gevins, A.

    2000-01-01

    OBJECTIVE: Task-related EEG is sensitive to changes in cognitive state produced by increased task difficulty and by transient impairment. If task-related EEG has high test-retest reliability, it could be used as part of a clinical test to assess changes in cognitive function. The aim of this study was to determine the reliability of the EEG recorded during the performance of a working memory (WM) task and a psychomotor vigilance task (PVT). METHODS: EEG was recorded while subjects rested quietly and while they performed the tasks. Within session (test-retest interval of approximately 1 h) and between session (test-retest interval of approximately 7 days) reliability was calculated for four EEG components: frontal midline theta at Fz, posterior theta at Pz, and slow and fast alpha at Pz. RESULTS: Task-related EEG was highly reliable within and between sessions (r0.9 for all components in WM task, and r0.8 for all components in the PVT). Resting EEG also showed high reliability, although the magnitude of the correlation was somewhat smaller than that of the task-related EEG (r0.7 for all 4 components). CONCLUSIONS: These results suggest that under appropriate conditions, task-related EEG has sufficient retest reliability for use in assessing clinical changes in cognitive status.

  10. Prediction of software operational reliability using testing environment factor

    International Nuclear Information System (INIS)

    Jung, Hoan Sung

    1995-02-01

    Software reliability is especially important to customers these days. The need to quantify software reliability of safety-critical systems has been received very special attention and the reliability is rated as one of software's most important attributes. Since the software is an intellectual product of human activity and since it is logically complex, the failures are inevitable. No standard models have been established to prove the correctness and to estimate the reliability of software systems by analysis and/or testing. For many years, many researches have focused on the quantification of software reliability and there are many models developed to quantify software reliability. Most software reliability models estimate the reliability with the failure data collected during the test assuming that the test environments well represent the operation profile. User's interest is on the operational reliability rather than on the test reliability, however. The experiences show that the operational reliability is higher than the test reliability. With the assumption that the difference in reliability results from the change of environment, testing environment factor comprising the aging factor and the coverage factor are defined in this work to predict the ultimate operational reliability with the failure data. It is by incorporating test environments applied beyond the operational profile into testing environment factor Test reliability can also be estimated with this approach without any model change. The application results are close to the actual data. The approach used in this thesis is expected to be applicable to ultra high reliable software systems that are used in nuclear power plants, airplanes, and other safety-critical applications

  11. A study of operational and testing reliability in software reliability analysis

    International Nuclear Information System (INIS)

    Yang, B.; Xie, M.

    2000-01-01

    Software reliability is an important aspect of any complex equipment today. Software reliability is usually estimated based on reliability models such as nonhomogeneous Poisson process (NHPP) models. Software systems are improving in testing phase, while it normally does not change in operational phase. Depending on whether the reliability is to be predicted for testing phase or operation phase, different measure should be used. In this paper, two different reliability concepts, namely, the operational reliability and the testing reliability, are clarified and studied in detail. These concepts have been mixed up or even misused in some existing literature. Using different reliability concept will lead to different reliability values obtained and it will further lead to different reliability-based decisions made. The difference of the estimated reliabilities is studied and the effect on the optimal release time is investigated

  12. Preliminary study for the reliability Assurance on results and procedure of the out-pile mechanical characterization test for a fuel assembly; Lateral Vibration Test (I)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Hee; Yoon, Kyung Hee; Kim, Hyung Kyu [KAERI, Daejeon (Korea, Republic of)

    2007-07-01

    The reliability assurance with respect to the test procedure and results of the out-pile mechanical performance test for the nuclear fuel assembly is an essential task to assure the test quality and to get a permission for fuel loading into the commercial reactor core. For the case of vibration test, proper management and appropriate calibration of instruments and devices used in the test, various efforts to minimize the possible error during the test and signal acquisition process are needed. Additionally, the deep understanding both of the theoretical assumption and simplification for the signal processing/modal analysis and of the functions of the devices used in the test were highly required. In this study, the overall procedure and result of lateral vibration test were assembly's mechanical characterization were briefly introduced. A series of measures to assure and improve the reliability of the vibration test were discussed.

  13. Preliminary study for the reliability Assurance on results and procedure of the out-pile mechanical characterization test for a fuel assembly; Lateral Vibration Test (I)

    International Nuclear Information System (INIS)

    Lee, Kang Hee; Yoon, Kyung Hee; Kim, Hyung Kyu

    2007-01-01

    The reliability assurance with respect to the test procedure and results of the out-pile mechanical performance test for the nuclear fuel assembly is an essential task to assure the test quality and to get a permission for fuel loading into the commercial reactor core. For the case of vibration test, proper management and appropriate calibration of instruments and devices used in the test, various efforts to minimize the possible error during the test and signal acquisition process are needed. Additionally, the deep understanding both of the theoretical assumption and simplification for the signal processing/modal analysis and of the functions of the devices used in the test were highly required. In this study, the overall procedure and result of lateral vibration test were assembly's mechanical characterization were briefly introduced. A series of measures to assure and improve the reliability of the vibration test were discussed

  14. Reliability of movement control tests in the lumbar spine

    Directory of Open Access Journals (Sweden)

    de Bruin Eling D

    2007-09-01

    Full Text Available Abstract Background Movement control dysfunction [MCD] reduces active control of movements. Patients with MCD might form an important subgroup among patients with non specific low back pain. The diagnosis is based on the observation of active movements. Although widely used clinically, only a few studies have been performed to determine the test reliability. The aim of this study was to determine the inter- and intra-observer reliability of movement control dysfunction tests of the lumbar spine. Methods We videoed patients performing a standardized test battery consisting of 10 active movement tests for motor control in 27 patients with non specific low back pain and 13 patients with other diagnoses but without back pain. Four physiotherapists independently rated test performances as correct or incorrect per observation, blinded to all other patient information and to each other. The study was conducted in a private physiotherapy outpatient practice in Reinach, Switzerland. Kappa coefficients, percentage agreements and confidence intervals for inter- and intra-rater results were calculated. Results The kappa values for inter-tester reliability ranged between 0.24 – 0.71. Six tests out of ten showed a substantial reliability [k > 0.6]. Intra-tester reliability was between 0.51 – 0.96, all tests but one showed substantial reliability [k > 0.6]. Conclusion Physiotherapists were able to reliably rate most of the tests in this series of motor control tasks as being performed correctly or not, by viewing films of patients with and without back pain performing the task.

  15. Research on the Reliability Testing of Electrical Automation Control Equipment

    OpenAIRE

    Yongjie Luo

    2014-01-01

    According to the author’s many years’ work experience, this paper first discusses the concepts of electrical automation control equipment reliability testing, and then analyzes the test method of electrical automation control equipment reliability testing, finally, on this basis, this article discusses how to determine the reliability test method of electrical automation control equipment. Results of this study will provide a useful reference for electrical automation control equipment reliab...

  16. Test-Retest Reliability and Predictive Validity of the Implicit Association Test in Children

    Science.gov (United States)

    Rae, James R.; Olson, Kristina R.

    2018-01-01

    The Implicit Association Test (IAT) is increasingly used in developmental research despite minimal evidence of whether children's IAT scores are reliable across time or predictive of behavior. When test-retest reliability and predictive validity have been assessed, the results have been mixed, and because these studies have differed on many…

  17. Reliability Generalization of the Alcohol Use Disorder Identification Test.

    Science.gov (United States)

    Shields, Alan L.; Caruso, John C.

    2002-01-01

    Evaluated the reliability of scores from the Alcohol Use Disorders Identification Test (AUDIT; J. Sounders and others, 1993) in a reliability generalization study based on 17 empirical journal articles. Results show AUDIT scores to be generally reliable for basic assessment. (SLD)

  18. Reliability and validity of two isometric squat tests.

    Science.gov (United States)

    Blazevich, Anthony J; Gill, Nicholas; Newton, Robert U

    2002-05-01

    The purpose of the present study was first to examine the reliability of isometric squat (IS) and isometric forward hack squat (IFHS) tests to determine if repeated measures on the same subjects yielded reliable results. The second purpose was to examine the relation between isometric and dynamic measures of strength to assess validity. Fourteen male subjects performed maximal IS and IFHS tests on 2 occasions and 1 repetition maximum (1-RM) free-weight squat and forward hack squat (FHS) tests on 1 occasion. The 2 tests were found to be highly reliable (intraclass correlation coefficient [ICC](IS) = 0.97 and ICC(IFHS) = 1.00). There was a strong relation between average IS and 1-RM squat performance, and between IFHS and 1-RM FHS performance (r(squat) = 0.77, r(FHS) = 0.76; p squat and FHS test performances (r squat and FHS test performance can be attributed to differences in the movement patterns of the tests

  19. Reliability performance of standby equipment with periodic testing

    International Nuclear Information System (INIS)

    Sim, S.H.

    1985-11-01

    In this report, the reliability performance of standby equipment subjected to periodic testing is studied. analytical expressions have been derived for reliability measures, such as the man accumulated operating time to failure, the expected number of tests between two consecutive failures, the mean time to failure following an emergency start-up and the probability of failing to complete an emergency mission of a specified duration. These results are useful for the reliability assessment of standby equipment such as combustion turbine units of the emergency power supply system, and of the Class III power system at a nuclear generating station

  20. A Reliability Test of a Complex System Based on Empirical Likelihood

    OpenAIRE

    Zhou, Yan; Fu, Liya; Zhang, Jun; Hui, Yongchang

    2016-01-01

    To analyze the reliability of a complex system described by minimal paths, an empirical likelihood method is proposed to solve the reliability test problem when the subsystem distributions are unknown. Furthermore, we provide a reliability test statistic of the complex system and extract the limit distribution of the test statistic. Therefore, we can obtain the confidence interval for reliability and make statistical inferences. The simulation studies also demonstrate the theorem results.

  1. Reliability tests for reactor internals replacement technology

    International Nuclear Information System (INIS)

    Fujimaki, K.; Uchiyama, J.; Ohtsubo, T.

    2000-01-01

    Structural damage due to aging degradation of LWR reactor internals has been reported in several nuclear plants. NUPEC has started a project to test the reliability of the technology for replacing reactor internals, which was directed at preventive maintenance before damage and repair after damage for the aging degradation. The project has been funded by the Ministry of International Trade and Industry (MITI) of Japan since 1995, and it follows the policy of a report that the MITI has formally issued in April 1996 summarizing the countermeasures to be considered for aging nuclear plants and equipment. This paper gives an outline of the whole test plans and the test results for the BWR reactor internals replacement methods; core shroud, ICM housing, and CRD Housing and stub tube. The test results have shown that the methods were reliable and the structural integrity was appropriate based on the evaluation. (author)

  2. Intertester reliability of the talk test in a cardiac rehabilitation population

    DEFF Research Database (Denmark)

    Petersen, Annemette Krintel; Maribo, Thomas; Hjortdal, Vibeke Elisabeth

    2013-01-01

    PURPOSE: The validity of the Talk Test (TT) is well documented, but the reliability of the test is not clear. The aim of this study was to assess the absolute and relative intertester reliability of the TT in cardiac patients. METHODS: Cardiac patients (n = 64) who had completed an exercise...... randomized to tests. Workload in watts at the first negative stage of the TT was registered as the test result. Patients and physiotherapists were blinded to test results of the first test. Absolute reliability of the TT was assessed with Bland-Altman plot, standard error of measurement, and minimal...... detectable change. Relative reliability was assessed using the intraclass correlation coefficient (ICC). RESULTS: Mean difference in peak workload between test and retest was 0.8 W (95% CI: -4.8 to 3.3). Limit of agreement was estimated to be +31/-32 W. Standard error of measurement was 11 W (95% CI: 10...

  3. Reliability Analysis and Test Planning using CAPO-Test for Existing Structures

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Engelund, S.; Faber, Michael Havbro

    2000-01-01

    Evaluation of the reliability of existing concrete structures often requires that the compressive strength of the concrete is estimated on the basis of tests performed with concrete samples from the structure considered. In this paper the CAPO-test method is considered. The different sources...... of uncertainty related to this method are described. It is shown how the uncertainty in the transformation from the CAPO-test results to estimates of the concrete strength can be modeled. Further, the statistical uncertainty is modeled using Bayesian statistics. Finally, it is shown how reliability-based optimal...... planning of CAPO-tests can be performed taking into account the expected costs due to the CAPO-tests and possible repair or failure of the structure considered. An illustrative example is presented where the CAPO-test is compared with conventional concrete cylinder compression tests performed on cores...

  4. Reliability tests for reactor internals rejuvenation technology

    International Nuclear Information System (INIS)

    Fujimaki, Katsumi; Hitoki, Yoichi; Otsubo, Toru; Uchiyama, Junichi

    1998-01-01

    Structural damage due to aging degradation of LWR reactor internals has been reported in several nuclear plants. NUPEC has started a project to test the reliability of the technology for rejuvenating reactor internals which has been funded by the Ministry of International Trade and Industry (MITI) of Japan since 1995. The project follows the policy of a report that the MITI has formally issued in April 1996 summarizing the countermeasures to be considered for aging nuclear plants and equipment. This paper gives an outline of the test plans and results which are directed at preventive maintenance before damage and repair after damage for reactor internals aging degradation. The test results for the replacement methods of ICM housing and BWR core shroud have shown that the methods were reliable and the structural integrity was appropriate based on the evaluation. (author)

  5. Reliability Testing of Cable on Environmental Humidity Condition

    International Nuclear Information System (INIS)

    Situmorang, Johnny; Puradwi, I.W; Sony T, D.T; Handoyo, Demon; Mulyanto, Dwijo; Kusmono, Slamet

    2000-01-01

    Reliability testing of cable on humidified condition has been carried out. As a result, the failure occurred due to reduction of current by increasing the resistance on rising temperature testing. For humidified condition the result which are observed did not significant at the stated condition of testing. The needed time up to the failure criteria increased as a temperature testing increased

  6. Prediction of software operational reliability using testing environment factors

    International Nuclear Information System (INIS)

    Jung, Hoan Sung; Seong, Poong Hyun

    1995-01-01

    A number of software reliability models have been developed to estimate and to predict software reliability. However, there are no established standard models to quantify software reliability. Most models estimate the quality of software in reliability figures such as remaining faults, failure rate, or mean time to next failure at the testing phase, and they consider them ultimate indicators of software reliability. Experience shows that there is a large gap between predicted reliability during development and reliability measured during operation, which means that predicted reliability, or so-called test reliability, is not operational reliability. Customers prefer operational reliability to test reliability. In this study, we propose a method that predicts operational reliability rather than test reliability by introducing the testing environment factor that quantifies the changes in environments

  7. A standard for test reliability in group research.

    Science.gov (United States)

    Ellis, Jules L

    2013-03-01

    Many authors adhere to the rule that test reliabilities should be at least .70 or .80 in group research. This article introduces a new standard according to which reliabilities can be evaluated. This standard is based on the costs or time of the experiment and of administering the test. For example, if test administration costs are 7 % of the total experimental costs, the efficient value of the reliability is .93. If the actual reliability of a test is equal to this efficient reliability, the test size maximizes the statistical power of the experiment, given the costs. As a standard in experimental research, it is proposed that the reliability of the dependent variable be close to the efficient reliability. Adhering to this standard will enhance the statistical power and reduce the costs of experiments.

  8. Developing MESA : an accelerated reliability test

    NARCIS (Netherlands)

    Baskoro, G.; Rouvroye, J.L.; Bacher, W.; Brombacher, A.C.

    2003-01-01

    This paper describes the on-going research on an accelerated reliability test strategy called MESA (Multiple Environment Stress Analysis) intended to find in a fast and efficient manner (potential) reliability problems during the design phase of high volume consumer products. This test has shown

  9. Reliability of four experimental mechanical pain tests in children

    Directory of Open Access Journals (Sweden)

    Soee AL

    2013-02-01

    Full Text Available Ann-Britt L Soee,1 Lise L Thomsen,2 Birte Tornoe,1,3 Liselotte Skov11Department of Pediatrics, Children’s Headache Clinic, Copenhagen University Hospital Herlev, Copenhagen, Denmark; 2Department of Neuropediatrics, Juliane Marie Centre, Copenhagen University Hospital Rigshospitalet, København Ø, Denmark; 3Department of Physiotherapy, Medical Department O, Copenhagen University Hospital Herlev, Herlev, DenmarkPurpose: In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT in healthy children. Furthermore, the aim was also to study the intersession reliability of the following four tests: (1 Total Tenderness Score; (2 PPT; (3 Visual Analog Scale score at suprapressure pain threshold; and (4 area under the curve (stimulus–response functions for pressure versus pain.Participants and methods: Twenty-five healthy school children, 8–14 years of age, participated. Test 2, PPT, was repeated three times at 2 minute intervals on the same day to estimate PPT intrasession reliability using Cronbach’s alpha. Tests 1–4 were repeated after median 21 (interquartile range 10.5–22 days, and Pearson’s correlation coefficient was used to describe the intersession reliability.Results: The PPT test was precise and reliable (Cronbach’s alpha ≥ 0.92. All tests showed a good to excellent correlation between days (intersessions r = 0.66–0.81. There were no indications of significant systematic differences found in any of the four tests between days.Conclusion: All tests seemed to be reliable measurements in pain evaluation in healthy children aged 8–14 years. Given the small sample size, this conclusion needs to be confirmed in future studies.Keywords: repeatability, intraindividual reliability, pressure pain threshold, pain measurement, algometer

  10. Reliability of provocative tests of motion sickness susceptibility

    Science.gov (United States)

    Calkins, D. S.; Reschke, M. F.; Kennedy, R. S.; Dunlop, W. P.

    1987-01-01

    Test-retest reliability values were derived from motion sickness susceptibility scores obtained from two successive exposures to each of three tests: (1) Coriolis sickness sensitivity test; (2) staircase velocity movement test; and (3) parabolic flight static chair test. The reliability of the three tests ranged from 0.70 to 0.88. Normalizing values from predictors with skewed distributions improved the reliability.

  11. Validity and reliability of the NAB Naming Test.

    Science.gov (United States)

    Sachs, Bonnie C; Rush, Beth K; Pedraza, Otto

    2016-05-01

    Confrontation naming is commonly assessed in neuropsychological practice, but few standardized measures of naming exist and those that do are susceptible to the effects of education and culture. The Neuropsychological Assessment Battery (NAB) Naming Test is a 31-item measure used to assess confrontation naming. Despite adequate psychometric information provided by the test publisher, there has been limited independent validation of the test. In this study, we investigated the convergent and discriminant validity, internal consistency, and alternate forms reliability of the NAB Naming Test in a sample of adults (Form 1: n = 247, Form 2: n = 151) clinically referred for neuropsychological evaluation. Results indicate adequate-to-good internal consistency and alternate forms reliability. We also found strong convergent validity as demonstrated by relationships with other neurocognitive measures. We found preliminary evidence that the NAB Naming Test demonstrates a more pronounced ceiling effect than other commonly used measures of naming. To our knowledge, this represents the largest published independent validation study of the NAB Naming Test in a clinical sample. Our findings suggest that the NAB Naming Test demonstrates adequate validity and reliability and merits consideration in the test arsenal of clinical neuropsychologists.

  12. Face Perception and Test Reliabilities in Congenital Prosopagnosia in Seven Tests

    Directory of Open Access Journals (Sweden)

    Janina Esins

    2016-01-01

    Full Text Available Congenital prosopagnosia, the innate impairment in recognizing faces, is a very heterogeneous disorder with different phenotypical manifestations. To investigate the nature of prosopagnosia in more detail, we tested 16 prosopagnosics and 21 controls with an extended test battery addressing various aspects of face recognition. Our results show that prosopagnosics exhibited significant impairments in several face recognition tasks: impaired holistic processing (they were tested amongst others with the Cambridge Face Memory Test (CFMT as well as reduced processing of configural information of faces. This test battery also revealed some new findings. While controls recognized moving faces better than static faces, prosopagnosics did not exhibit this effect. Furthermore, prosopagnosics had significantly impaired gender recognition—which is shown on a groupwise level for the first time in our study. There was no difference between groups in the automatic extraction of face identity information or in object recognition as tested with the Cambridge Car Memory Test. In addition, a methodological analysis of the tests revealed reduced reliability for holistic face processing tests in prosopagnosics. To our knowledge, this is the first study to show that prosopagnosics showed a significantly reduced reliability coefficient (Cronbach’s alpha in the CFMT compared to the controls. We suggest that compensatory strategies employed by the prosopagnosics might be the cause for the vast variety of response patterns revealed by the reduced test reliability. This finding raises the question whether classical face tests measure the same perceptual processes in controls and prosopagnosics.

  13. Test re-test reliability and construct validity of the star-track test of manual dexterity

    DEFF Research Database (Denmark)

    Kildebro, Niels; Amirian, Ilda; Gögenur, Ismail

    2015-01-01

    Objectives. We wished to determine test re-test reliability and construct validity of the star-track test of manual dexterity. Design. Test re-test reliability was examined in a controlled study. Construct validity was tested in a blinded randomized crossover study. Setting. The study was performed...... at a university hospital in Denmark. Participants. A total of 11 subjects for test re-test and 20 subjects for the construct validity study were included. All subjects were healthy volunteers. Intervention. The test re-test trial had two measurements with 2 days pause in between. The interventions...... in the construct validity study included baseline measurement, intervention 1: fatigue, intervention 2: stress, and intervention 3: fatigue and stress. There was a 2 day pause between each intervention. Main outcome measure. An integrated measure of completion time and number of errors was used. Results. All...

  14. CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.

    Science.gov (United States)

    Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David

    2016-03-01

    Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC 2 ,: 1  = 0.59) over Bath-Thermode (ICC 2 ,: 1  = 0.34) or Two-Thermodes (ICC 2 ,: 1  = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC 2 ,: 1  = 0.76 vs ICC 2 ,: 1  = 0.16). Conditioned test-stimulus pain scores were of good (ICC 2 ,: 1  = 0.62) or fair (ICC 2 ,: 1  = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC 2 ,: 1  = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e

  15. Reliability of two social cognition tests: The combined stories test and the social knowledge test.

    Science.gov (United States)

    Thibaudeau, Élisabeth; Cellard, Caroline; Legendre, Maxime; Villeneuve, Karèle; Achim, Amélie M

    2018-04-01

    Deficits in social cognition are common in psychiatric disorders. Validated social cognition measures with good psychometric properties are necessary to assess and target social cognitive deficits. Two recent social cognition tests, the Combined Stories Test (COST) and the Social Knowledge Test (SKT), respectively assess theory of mind and social knowledge. Previous studies have shown good psychometric properties for these tests, but the test-retest reliability has never been documented. The aim of this study was to evaluate the test-retest reliability and the inter-rater reliability of the COST and the SKT. The COST and the SKT were administered twice to a group of forty-two healthy adults, with a delay of approximately four weeks between the assessments. Excellent test-retest reliability was observed for the COST, and a good test-retest reliability was observed for the SKT. There was no evidence of practice effect. Furthermore, an excellent inter-rater reliability was observed for both tests. This study shows a good reliability of the COST and the SKT that adds to the good validity previously reported for these two tests. These good psychometrics properties thus support that the COST and the SKT are adequate measures for the assessment of social cognition. Copyright © 2018. Published by Elsevier B.V.

  16. Test-retest reliability of the Progressive Isoinertial Lifting Evaluation (PILE).

    Science.gov (United States)

    Lygren, Hildegunn; Dragesund, Tove; Joensen, Jón; Ask, Tove; Moe-Nilssen, Rolf

    2005-05-01

    A repeated measures single group design. To investigate test-retest reliability of Progressive Isoinertial Lifting Evaluation on patients with long lasting musculoskeletal problems related to the lumbar spine. Test-retest reliability has been satisfactory in healthy men. Test-retest reliability for clinical populations has not been reported. A total of 31 patients (17 women and 14 men) with long lasting low back pain participated in the study. The patients were tested twice at an interval of 2 days and at the same time of the day. The heaviest load that the patient could lift 4 times was used as outcome measure. The error of measurement indicates that the true result in 95% of cases will be within +/-4.5 kg from the measured value, while the difference between 2 measurements in 95% of cases will be less than 6.4 kg. Intra-class correlation (1,1) was 0.91. Relative test-retest reliability was high assessed by intra-class correlation, but absolute measurement variability reported as the smallest detectable difference has relevance for the interpretation of clinical test results and should also be considered.

  17. The Reliability of Results from National Tests, Public Examinations, and Vocational Qualifications in England

    Science.gov (United States)

    He, Qingping; Opposs, Dennis

    2012-01-01

    National tests, public examinations, and vocational qualifications in England are used for a variety of purposes, including the certification of individual learners in different subject areas and the accountability of individual professionals and institutions. However, there has been ongoing debate about the reliability and validity of their…

  18. Test–re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females

    Directory of Open Access Journals (Sweden)

    Chris Beardsley

    2016-03-01

    Full Text Available Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test–re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81–0.88, test–re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88–0.95, and test–re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65 and good on the right side (ICC = 0.85. Conclusion. Inter-rater reliability and test–re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test–re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test–re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.

  19. Test-retest reliability of infant event related potentials evoked by faces.

    Science.gov (United States)

    Munsters, N M; van Ravenswaaij, H; van den Boomen, C; Kemner, C

    2017-04-05

    Reliable measures are required to draw meaningful conclusions regarding developmental changes in longitudinal studies. Little is known, however, about the test-retest reliability of face-sensitive event related potentials (ERPs), a frequently used neural measure in infants. The aim of the current study is to investigate the test-retest reliability of ERPs typically evoked by faces in 9-10 month-old infants. The infants (N=31) were presented with neutral, fearful and happy faces that contained only the lower or higher spatial frequency information. They were tested twice within two weeks. The present results show that the test-retest reliability of the face-sensitive ERP components is moderate (P400 and Nc) to substantial (N290). However, there is low test-retest reliability for the effects of the specific experimental manipulations (i.e. emotion and spatial frequency) on the face-sensitive ERPs. To conclude, in infants the face-sensitive ERP components (i.e. N290, P400 and Nc) show adequate test-retest reliability, but not the effects of emotion and spatial frequency on these ERP components. We propose that further research focuses on investigating elements that might increase the test-retest reliability, as adequate test-retest reliability is necessary to draw meaningful conclusions on individual developmental trajectories of the face-sensitive ERPs in infants. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Link, H.; Keller, J.; Guo, Y.; McNiff, B.

    2013-04-01

    Gearboxes in wind turbines have not been achieving their expected design life even though they commonly meet or exceed the design criteria specified in current design standards. One of the basic premises of the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) is that the low gearbox reliability results from the absence of critical elements in the design process or insufficient design tools. Key goals of the GRC are to improve design approaches and analysis tools and to recommend practices and test methods resulting in improved design standards for wind turbine gearboxes that lower the cost of energy (COE) through improved reliability. The GRC uses a combined gearbox testing, modeling and analysis approach, along with a database of information from gearbox failures collected from overhauls and investigation of gearbox condition monitoring techniques to improve wind turbine operations and maintenance practices. Testing of Gearbox 2 (GB2) using the two-speed turbine controller that has been used in prior testing. This test series will investigate non-torque loads, high-speed shaft misalignment, and reproduction of field conditions in the dynamometer. This test series will also include vibration testing using an eddy-current brake on the gearbox's high speed shaft.

  1. Test-retest reliability for aerodynamic measures of voice.

    Science.gov (United States)

    Awan, Shaheen N; Novaleski, Carolyn K; Yingling, Julie R

    2013-11-01

    The purpose of this study was to investigate the intrasubject reliability of aerodynamic characteristics of the voice within typical/normal speakers across testing sessions using the Phonatory Aerodynamic System (PAS 6600; KayPENTAX, Montvale, NJ). Participants were 60 healthy young adults (30 males and 30 females) between the ages 18 and 31 years with perceptually typical voice. Participants were tested using the PAS 6600 (Phonatory Aerodynamic System) on two separate days with approximately 1 week between each session at approximately the same time of day. Four PAS protocols were conducted (vital capacity, maximum sustained phonation, comfortable sustained phonation, and voicing efficiency) and measures of expiratory volume, maximum phonation time, mean expiratory airflow (during vowel production) and target airflow (obtained via syllable repetition), peak air pressure, aerodynamic power, aerodynamic resistance, and aerodynamic efficiency were obtained during each testing session. Associated acoustic measures of vocal intensity and frequency were also collected. All phonations were elicited at comfortable pitch and loudness. All aerodynamic and associated variables evaluated in this study showed useable test-retest reliability (ie, intraclass correlation coefficients [ICCs] ≥ 0.60). A high degree of mean test-retest reliability was found across all subjects for aerodynamic and associated acoustic measurements of vital capacity, maximum sustained phonation, glottal resistance, and vocal intensity (all with ICCs > 0.75). Although strong ICCs were observed for measures of glottal power and mean expiratory airflow in males, weaker overall results for these measures (ICC range: 0.60-0.67) were observed in females subjects and sizable coefficients of variation were observed for measures of power, resistance, and efficiency in both men and women. Differences in degree of reliability from measure to measure were revealed in greater detail using methods such as ICCs and

  2. Construction and Evaluation of Reliability and Validity of Reasoning Ability Test

    Science.gov (United States)

    Bhat, Mehraj A.

    2014-01-01

    This paper is based on the construction and evaluation of reliability and validity of reasoning ability test at secondary school students. In this paper an attempt was made to evaluate validity, reliability and to determine the appropriate standards to interpret the results of reasoning ability test. The test includes 45 items to measure six types…

  3. Test-retest reliability and predictive validity of the Implicit Association Test in children.

    Science.gov (United States)

    Rae, James R; Olson, Kristina R

    2018-02-01

    The Implicit Association Test (IAT) is increasingly used in developmental research despite minimal evidence of whether children's IAT scores are reliable across time or predictive of behavior. When test-retest reliability and predictive validity have been assessed, the results have been mixed, and because these studies have differed on many factors simultaneously (lag-time between testing administrations, domain, etc.), it is difficult to discern what factors may explain variability in existing test-retest reliability and predictive validity estimates. Across five studies (total N = 519; ages 6- to 11-years-old), we manipulated two factors that have varied in previous developmental research-lag-time and domain. An internal meta-analysis of these studies revealed that, across three different methods of analyzing the data, mean test-retest (rs of .48, .38, and .34) and predictive validity (rs of .46, .20, and .10) effect sizes were significantly greater than zero. While lag-time did not moderate the magnitude of test-retest coefficients, whether we observed domain differences in test-retest reliability and predictive validity estimates was contingent on other factors, such as how we scored the IAT or whether we included estimates from a unique sample (i.e., a sample containing gender typical and gender diverse children). Recommendations are made for developmental researchers that utilize the IAT in their research. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  4. Models on reliability of non-destructive testing

    International Nuclear Information System (INIS)

    Simola, K.; Pulkkinen, U.

    1998-01-01

    The reliability of ultrasonic inspections has been studied in e.g. international PISC (Programme for the Inspection of Steel Components) exercises. These exercises have produced a large amount of information on the effect of various factors on the reliability of inspections. The information obtained from reliability experiments are used to model the dependency of flaw detection probability on various factors and to evaluate the performance of inspection equipment, including the sizing accuracy. The information from experiments is utilised in a most effective way when mathematical models are applied. Here, some statistical models for reliability of non-destructive tests are introduced. In order to demonstrate the use of inspection reliability models, they have been applied to the inspection results of intergranular stress corrosion cracking (IGSCC) type flaws in PISC III exercise (PISC 1995). The models are applied to both flaw detection frequency data of all inspection teams and to flaw sizing data of one participating team. (author)

  5. Reliability of D-Dimer test results in deciding the necessity of performing CTA in high risk population to establish the diagnosis of PE

    Directory of Open Access Journals (Sweden)

    Saher Ebrahim Taman

    2016-06-01

    Conclusion: Negative D-Dimer test is a reliable diagnostic modality to rule out the need for CT Angiography in patients at high risk population of PE. However, positive test results cannot confirm the diagnosis and further testing is warranted.

  6. Test of understanding of vectors: A reliable multiple-choice vector concept test

    Science.gov (United States)

    Barniol, Pablo; Zavala, Genaro

    2014-06-01

    In this article we discuss the findings of our research on students' understanding of vector concepts in problems without physical context. First, we develop a complete taxonomy of the most frequent errors made by university students when learning vector concepts. This study is based on the results of several test administrations of open-ended problems in which a total of 2067 students participated. Using this taxonomy, we then designed a 20-item multiple-choice test [Test of understanding of vectors (TUV)] and administered it in English to 423 students who were completing the required sequence of introductory physics courses at a large private Mexican university. We evaluated the test's content validity, reliability, and discriminatory power. The results indicate that the TUV is a reliable assessment tool. We also conducted a detailed analysis of the students' understanding of the vector concepts evaluated in the test. The TUV is included in the Supplemental Material as a resource for other researchers studying vector learning, as well as instructors teaching the material.

  7. OPTIMUM DESIGN OF EXPERIMENTS FOR ACCELERATED RELIABILITY TESTING

    Directory of Open Access Journals (Sweden)

    Sebastian Marian ZAHARIA

    2014-05-01

    Full Text Available In this paper is presented a case study that demonstrates how design to experiments (DOE information can be used to design better accelerated reliability tests. In the case study described in this paper, will be done a comparison and optimization between main accelerated reliability test plans (3 Level Best Standard Plan, 3 Level Best Compromise Plan, 3 Level Best Equal Expected Number Failing Plan, 3 Level 4:2:1 Allocation Plan. Before starting an accelerated reliability test, it is advisable to have a plan that helps in accurately estimating reliability at operating conditions while minimizing test time and costs. A test plan should be used to decide on the appropriate stress levels that should be used (for each stress type and the amount of the test units that need to be allocated to the different stress levels (for each combination of the different stress types' levels. For the case study it used ALTA 7 software what provides a complete analysis for data from accelerated reliability tests

  8. Reliability demonstration test planning: A three dimensional consideration

    International Nuclear Information System (INIS)

    Yadav, Om Prakash; Singh, Nanua; Goel, Parveen S.

    2006-01-01

    Increasing customer demand for reliability, fierce market competition on time-to-market and cost, and highly reliable products are making reliability testing more challenging task. This paper presents a systematic approach for identifying critical elements (subsystems and components) of the system and deciding the types of test to be performed to demonstrate reliability. It decomposes the system into three dimensions (i.e. physical, functional and time) and identifies critical elements in the design by allocating system level reliability to each candidate. The decomposition of system level reliability is achieved by using criticality index. The numerical value of criticality index for each candidate is derived based on the information available from failure mode and effects analysis (FMEA) document or warranty data from a prior system. It makes use of this information to develop reliability demonstration test plan for the identified (critical) failure mechanisms and physical elements. It also highlights the benefits of using prior information in order to locate critical spots in the design and in subsequent development of test plans. A case example is presented to demonstrate the proposed approach

  9. Test Re-Test Reliability of Four Versions of the 3-Cone Test in Non-Athletic Men

    Directory of Open Access Journals (Sweden)

    Jason G. Langley, Robert D. Chetlin

    2017-03-01

    Full Text Available Until recently, measurement and evaluation in sport science, especially agility testing, has not always included key elements of proper test construction. Often tests are published without reporting reliability and validity analysis for a specific population. The purpose of the present study was to examine the test re-test reliability of four versions of the 3-Cone Test (3CT, and provide guidance on proper test construction for testing agility in athletic populations. Forty male students enrolled in classes in the Department of Physical Education at a mid-Atlantic university participated. On each of test day participants performed 10 trials. In random order, they performed three trials to the right (3CTR, standard test, three to the left (3CTL, and two modified trials (3CTAR and 3CTAL, which included a reactive component in which a visual cue was given to indicate direction. Intra-class correlation coefficients (ICC indicated a moderate to high reliability for the four tests, 3CTR 0.79 (0.64-0.88, 95%CI, 3CTL 0.73 (0.55-0.85, 3CTAR 0.85(0.74-0.92, and 3CTAL 0.79 (0.64-0.88. Small standard error of the measurement (SEM was found; range 0.09 to 0.10. Pearson correlations between tests were high (0.82-0.92 on day one as well as day two (0.72-0.85. These results indicate each version of the 3-Cone Test is reliable; however, further tests are needed with specific athletic populations. Only the 3CTAR and 3CTAL are tests of agility due to the inclusion of a reactive component. Future studies examining agility testing and training should incorporate technological elements, including automated timing systems and motion capture analysis. Such instrumentation will allow for optimal design of tests that simulate sport-specific game conditions.

  10. Test-retest reliability and validity of the Sniffin' TOM odor memory test.

    Science.gov (United States)

    Croy, Ilona; Zehner, Cora; Larsson, Maria; Zucco, Gesualdo M; Hummel, Thomas

    2015-03-01

    Few attempts have been made to develop an olfactory test that captures episodic retention of olfactory information. Assessment of episodic odor memory is of particular interest in aging and in the cognitively impaired as both episodic memory deficits and olfactory loss have been targeted as reliable hallmarks of cognitive decline and impending dementia. Here, 96 healthy participants (18-92 years) and an additional 19 older people with mild cognitive impairment were tested (73-82 years). Participants were presented with 8 common odors with intentional encoding instructions that were followed by a yes-no recognition test. After recognition completion, participants were asked to identify all odors by means of free or cued identification. A retest of the odor memory test (Sniffin' TOM = test of odor memory) took place 17 days later. The results revealed satisfactory test-retest reliability (0.70) of odor recognition memory. Both recognition and identification performance were negatively affected by age and more pronounced among the cognitively impaired. In conclusion, the present work presents a reliable, valid, and simple test of episodic odor recognition memory that may be used in clinical groups where both episodic memory deficits and olfactory loss are prevalent preclinically such as Alzheimer's disease. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. TEST-RETEST RELIABILITY OF THE CLOSED KINETIC CHAIN UPPER EXTREMITY STABILITY TEST (CKCUEST) IN ADOLESCENTS: RELIABILITY OF CKCUEST IN ADOLESCENTS.

    Science.gov (United States)

    de Oliveira, Valéria M A; Pitangui, Ana C R; Nascimento, Vinícius Y S; da Silva, Hítalo A; Dos Passos, Muana H P; de Araújo, Rodrigo C

    2017-02-01

    The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) has been proposed as an option to assess upper limb function and stability; however, there are few studies that support the use of this test in adolescents. The purpose of the present study was to investigate the intersession reliability and agreement of three CKCUEST scores in adolescents and establish clinimetric values for this test. Test-retest reliability. Twenty-five healthy adolescents of both sexes were evaluated. The subjects performed two CKCUEST with an interval of one week between the tests. An intraclass correlation coefficient (ICC 3,3 ) two-way mixed model with a 95% interval of confidence was utilized to determine intersession reliability. A Bland-Altman graph was plotted to analyze the agreement between assessments. The presence of systematic error was evaluated by a one-sample t test. The difference between the evaluation and reevaluation was observed using a paired-sample t test. The level of significance was set at 0.05. Standard error of measurements and minimum detectable changes were calculated. The intersession reliability of the average touches score, normalized score, and power score were 0.68, 0.68 and 0.87, the standard error of measurement were 2.17, 1.35 and 6.49, and the minimal detectable change was 6.01, 3.74 and 17.98, respectively. The presence of systematic error (p test with moderate to excellent reliability when used with adolescents. The CKCUEST is a measurement with moderate to excellent reliability for adolescents. 2b.

  12. Reliability demonstration test planning using bayesian analysis

    International Nuclear Information System (INIS)

    Chandran, Senthil Kumar; Arul, John A.

    2003-01-01

    In Nuclear Power Plants, the reliability of all the safety systems is very critical from the safety viewpoint and it is very essential that the required reliability requirements be met while satisfying the design constraints. From practical experience, it is found that the reliability of complex systems such as Safety Rod Drive Mechanism is of the order of 10 -4 with an uncertainty factor of 10. To demonstrate the reliability of such systems is prohibitive in terms of cost and time as the number of tests needed is very large. The purpose of this paper is to develop a Bayesian reliability demonstrating testing procedure for exponentially distributed failure times with gamma prior distribution on the failure rate which can be easily and effectively used to demonstrate component/subsystem/system reliability conformance to stated requirements. The important questions addressed in this paper are: With zero failures, how long one should perform the tests and how many components are required to conclude with a given degree of confidence, that the component under test, meets the reliability requirement. The procedure is explained with an example. This procedure can also be extended to demonstrate with more number of failures. The approach presented is applicable for deriving test plans for demonstrating component failure rates of nuclear power plants, as the failure data for similar components are becoming available in existing plants elsewhere. The advantages of this procedure are the criterion upon which the procedure is based is simple and pertinent, the fitting of the prior distribution is an integral part of the procedure and is based on the use of information regarding two percentiles of this distribution and finally, the procedure is straightforward and easy to apply in practice. (author)

  13. Assessing Reliability of Two Versions of Vocabulary Levels Tests in Iranian Context

    Directory of Open Access Journals (Sweden)

    Aso Bayazidi

    2017-02-01

    Full Text Available This study examined the equivalence and reliability of the two versions of the Vocabulary Levels Test in an Iranian context. This study was motivated by the fact that the Vocabulary Levels test is increasingly being used in Iran for both research and pedagogical purposes without having been checked for validity and reliability in this context. The equivalence and reliability of the two versions of the test were examined through the parallel-form approach to reliability in Classical True Score theory. Seventy-five intermediate learners of English as a foreign language at the Iran Language Institute took the two versions of the test with one week interval between the two administrations in a counterbalanced fashion. To examine the equivalence of the two versions, the means and variances of the scores obtained for the two tests were compared using paired-sample t-test and one-way ANOVA, respectively. The results of the analyses indicated that the difference between the means of the two versions was significant, and the two versions cannot be considered as parallel forms. To assess the reliability of the two versions, the correlation between the scores obtained from them was estimated using Pearson Product Moment correlation. The results of the analyses showed that the two versions are highly correlated and are reliable tests. It is concluded that the two versions should not be treated as equivalent in longitudinal and gain score studies.

  14. Factors that influence standard automated perimetry test results in glaucoma: test reliability, technician experience, time of day, and season.

    Science.gov (United States)

    Junoy Montolio, Francisco G; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M

    2012-10-09

    To determine the influence of several factors on standard automated perimetry test results in glaucoma. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience, time of day, and season on the mean deviation (MD) was determined by performing linear regression analysis of MD against time on a series of visual fields and subsequently performing a multiple linear regression analysis with the MD residuals as dependent variable and the factors mentioned above as independent variables. Analyses were performed with and without adjustment for the test reliability (fixation losses and false-positive and false-negative answers) and with and without stratification according to disease stage (baseline MD). Mean follow-up was 9.4 years, with on average 10.8 tests per patient. Technician experience, time of day, and season were associated with the MD. Approximately 0.2 dB lower MD values were found for inexperienced technicians (P Technician experience, time of day, season, and the percentage of false-positive answers have a significant influence on the MD of standard automated perimetry.

  15. Proving test on the reliability for nuclear valves

    International Nuclear Information System (INIS)

    Kajiyama, Yasuo; Tashiro, Hisao; Uga, Takeo; Maeda, Shunichi.

    1986-01-01

    Since valves are the most common components, they could be the most frequent causes of troubles in nuclear power plants. This proving test, therefore, has an important meaning to examine and verify the reliability of various valves under simulating conditions of abnormal and transient operations of the nuclear power plant. The test was performed mainly for the various types and pressure ratings of valves which were used in the primary and secondary systems in BWR and PWR nuclear power plants and which had major operating or safety related functions in those nuclear power plants. The results of the proving test, confirmed for more than four years, showed relatively favourable performance of the tested valves. It is concluded that performances of valves including operability, seat sealing and structural integrity were proved under the thermal cycling, vibration and pipe reaction load conditions. Operating functions during and after accident such as loss of coolant accident were satisfactory. From these results, it was considered that the purpose of this proving test was satisfactorily fulfilled. Several data accumulated by the test would be useful to get better reliability if it was evaluated with the actually experienced data of valves in the nuclear power plants. (Nogami, K.)

  16. Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.

    Science.gov (United States)

    Taylor, Karen; Bulsara, Max; Monterosso, Leanne

    2018-01-01

    Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.

  17. Validity and Reliability of Baseline Testing in a Standardized Environment.

    Science.gov (United States)

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Assessment of the quality of test results from selected civil engineering material testing laboratories in Tanzania

    CSIR Research Space (South Africa)

    Mbawala, SJ

    2017-12-01

    Full Text Available Civil and geotechnical engineering material testing laboratories are expected to produce accurate and reliable test results. However, the ability of laboratories to produce accurate and reliable test results depends on many factors, among others...

  19. A test chip for automatic reliability measurements of interconnect vias

    NARCIS (Netherlands)

    Lippe, K.; Hasper, A.; Elfrink, G.W.; Niehof, J.; Kerkhoff, Hans G.

    1992-01-01

    A test circuit for electromigration reliability measurements was designed and tested. The device under test (DUT) is a via-hole chain. The test circuit permits simultaneous measurements of a number of DUTs, and a fatal error of one DUT does not influence the measurement results of the other DUTs.

  20. Reliability Evaluation of Concentric Butterfly Valve Using Statistical Hypothesis Test

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Mu Seong; Choi, Jong Sik; Choi, Byung Oh; Kim, Do Sik [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of)

    2015-12-15

    A butterfly valve is a type of flow-control device typically used to regulate a fluid flow. This paper presents an estimation of the shape parameter of the Weibull distribution, characteristic life, and B10 life for a concentric butterfly valve based on a statistical analysis of the reliability test data taken before and after the valve improvement. The difference in the shape and scale parameters between the existing and improved valves is reviewed using a statistical hypothesis test. The test results indicate that the shape parameter of the improved valve is similar to that of the existing valve, and that the scale parameter of the improved valve is found to have increased. These analysis results are particularly useful for a reliability qualification test and the determination of the service life cycles.

  1. Reliability Evaluation of Concentric Butterfly Valve Using Statistical Hypothesis Test

    International Nuclear Information System (INIS)

    Chang, Mu Seong; Choi, Jong Sik; Choi, Byung Oh; Kim, Do Sik

    2015-01-01

    A butterfly valve is a type of flow-control device typically used to regulate a fluid flow. This paper presents an estimation of the shape parameter of the Weibull distribution, characteristic life, and B10 life for a concentric butterfly valve based on a statistical analysis of the reliability test data taken before and after the valve improvement. The difference in the shape and scale parameters between the existing and improved valves is reviewed using a statistical hypothesis test. The test results indicate that the shape parameter of the improved valve is similar to that of the existing valve, and that the scale parameter of the improved valve is found to have increased. These analysis results are particularly useful for a reliability qualification test and the determination of the service life cycles

  2. Proving Test on the Reliability for Reactor Containment Vessel

    International Nuclear Information System (INIS)

    Takumi, K.; Nonaka, A.

    1988-01-01

    NUPEC (Nuclear Power Engineering Test Center) has started an eight-year project of Proving Test on the Reliability for Reactor Containment Vessel since June 1987. The objective of this project is to confirm the integrity of containment vessels under severe accident conditions. This paper shows the outline of this project. The test Items are (1) Hydrogen mixing and distribution test, (2) Hydrogen burning test, (3) Iodine trapping characteristics test, and (4) Structural behavior test. Based on the test results, computer codes are verified and as the results of analysis and evaluation by the computer codes, containment integrity is to be confirmed

  3. Basic Concepts in Classical Test Theory: Tests Aren't Reliable, the Nature of Alpha, and Reliability Generalization as a Meta-analytic Method.

    Science.gov (United States)

    Helms, LuAnn Sherbeck

    This paper discusses the fact that reliability is about scores and not tests and how reliability limits effect sizes. The paper also explores the classical reliability coefficients of stability, equivalence, and internal consistency. Stability is concerned with how stable test scores will be over time, while equivalence addresses the relationship…

  4. Accounting for Proof Test Data in a Reliability Based Design Optimization Framework

    Science.gov (United States)

    Ventor, Gerharad; Scotti, Stephen J.

    2012-01-01

    This paper investigates the use of proof (or acceptance) test data during the reliability based design optimization of structural components. It is assumed that every component will be proof tested and that the component will only enter into service if it passes the proof test. The goal is to reduce the component weight, while maintaining high reliability, by exploiting the proof test results during the design process. The proposed procedure results in the simultaneous design of the structural component and the proof test itself and provides the designer with direct control over the probability of failing the proof test. The procedure is illustrated using two analytical example problems and the results indicate that significant weight savings are possible when exploiting the proof test results during the design process.

  5. NDE reliability gains from combining eddy-current and ultrasonic testing

    International Nuclear Information System (INIS)

    Horn, D.; Mayo, W.R.

    1999-01-01

    We investigate statistical methods for combining the results of two complementary inspection techniques, eddy-current and ultrasonic testing. The reliability of rejection/acceptance decisions based on combined information is compared with that based on each inspection technique individually. The measured reliability increases with the amount of information incorporated in the decision. (author)

  6. Design for reliability: NASA reliability preferred practices for design and test

    Science.gov (United States)

    Lalli, Vincent R.

    1994-01-01

    This tutorial summarizes reliability experience from both NASA and industry and reflects engineering practices that support current and future civil space programs. These practices were collected from various NASA field centers and were reviewed by a committee of senior technical representatives from the participating centers (members are listed at the end). The material for this tutorial was taken from the publication issued by the NASA Reliability and Maintainability Steering Committee (NASA Reliability Preferred Practices for Design and Test. NASA TM-4322, 1991). Reliability must be an integral part of the systems engineering process. Although both disciplines must be weighed equally with other technical and programmatic demands, the application of sound reliability principles will be the key to the effectiveness and affordability of America's space program. Our space programs have shown that reliability efforts must focus on the design characteristics that affect the frequency of failure. Herein, we emphasize that these identified design characteristics must be controlled by applying conservative engineering principles.

  7. Reliability of a science admission test (HAM-Nat) at Hamburg medical school.

    Science.gov (United States)

    Hissbach, Johanna; Klusmann, Dietrich; Hampe, Wolfgang

    2011-01-01

    The University Hospital in Hamburg (UKE) started to develop a test of knowledge in natural sciences for admission to medical school in 2005 (Hamburger Auswahlverfahren für Medizinische Studiengänge, Naturwissenschaftsteil, HAM-Nat). This study is a step towards establishing the HAM-Nat. We are investigating parallel forms reliability, the effect of a crash course in chemistry on test results, and correlations of HAM-Nat test results with a test of scientific reasoning (similar to a subtest of the "Test for Medical Studies", TMS). 316 first-year students participated in the study in 2007. They completed different versions of the HAM-Nat test which consisted of items that had already been used (HN2006) and new items (HN2007). Four weeks later half of the participants were tested on the HN2007 version of the HAM-Nat again, while the other half completed the test of scientific reasoning. Within this four week interval students were offered a five day chemistry course. Parallel forms reliability for four different test versions ranged from r(tt)=.53 to r(tt)=.67. The retest reliabilities of the HN2007 halves were r(tt)=.54 and r(tt )=.61. Correlations of the two HAM-Nat versions with the test of scientific reasoning were r=.34 und r=.21. The crash course in chemistry had no effect on HAM-Nat scores. The results suggest that further versions of the test of natural sciences will not easily conform to the standards of internal consistency, parallel-forms reliability and retest reliability. Much care has to be taken in order to assemble items which could be used interchangeably for the construction of new test versions. The test of scientific reasoning and the HAM-Nat are tapping different constructs. Participation in a chemistry course did not improve students' achievement, probably because the content of the course was not coordinated with the test and many students lacked of motivation to do well in the second test.

  8. Reasoning with Inductive Argument Test: A Study of Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Mehmet Emrah Karadere

    2013-11-01

    Full Text Available Reasoning with Inductive Argument Test:A Study of Validity and Reliability Objective: The aim of our study is to research reliability and validity and to evaluate the usability of Turkish version of Reasoning with Inductive Argument Test (RIAT in Turkish healty population. Method: 51 healty volunteers who work in Ankara Dıskapi Yildirim Beyazit Research and Training Hospital participated in this study. Reasoning with Inductive Argument Test (RIAT was translated into Turkish by three clinical good knowledge of English. Participants were given a sociodemographic data form, and RIAT were performed by clinicians. To test the reliability of the Turkish version of RIAT, Cronbach’s alpha coefficient was calculated and the halving method was used for the test. Results: The internal consistency of the Reasoning with Inductive Argument Test (RIAT items, Cronbach’s alpha internal consistency coefficient measurements of 0.73 was found to be statistically significant. Spearman-Brown coefficient that determines the reliability of the whole test r=0.74 was found. Kurtosis values of all the items was below 1.5 and the percentages in the second evaluation were mainly lower. At the same time, both change in belief between self produced RIAT options and given RIAT options (p=0.02, z=-2296 as well as changes in beliefs between related and unrelated items for Obsessive Compulsive Disorder (OCD difference (p=0.03, z=-2.199 were significant. Conclusion: The preliminary data obtained from the study of reliability and validity of the scale shows that ‘Reasoning with Inductive Argument Test’ supports reliability and validity in Turkish population.

  9. Development of seismic technology and reliability based on vibration tests

    International Nuclear Information System (INIS)

    Sasaki, Youichi

    1997-01-01

    This paper deals with some of the vibration tests and investigations on the seismic safety of nuclear power plants (NPPs) in Japan. To ensure the reliability of the seismic safety of nuclear power plants, nuclear power plants in Japan have been designed according to the Technical Guidelines for Aseismic Design of Nuclear Power Plants. This guideline has been developed based on technical date base and findings which were obtained from many vibration tests and investigations. Besides the tests for the guideline, proving tests on seismic reliability of operating nuclear power plants equipment and systems have been carried out. In this paper some vibration tests and their evaluation results are presented. They have crucially contributed to develop the guideline. (J.P.N.)

  10. Development of seismic technology and reliability based on vibration tests

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Youichi [Nuclear Power Engineering Corp., Tokyo (Japan)

    1997-03-01

    This paper deals with some of the vibration tests and investigations on the seismic safety of nuclear power plants (NPPs) in Japan. To ensure the reliability of the seismic safety of nuclear power plants, nuclear power plants in Japan have been designed according to the Technical Guidelines for Aseismic Design of Nuclear Power Plants. This guideline has been developed based on technical date base and findings which were obtained from many vibration tests and investigations. Besides the tests for the guideline, proving tests on seismic reliability of operating nuclear power plants equipment and systems have been carried out. In this paper some vibration tests and their evaluation results are presented. They have crucially contributed to develop the guideline. (J.P.N.)

  11. Reliability test for reactor internals rejuvenation technology

    International Nuclear Information System (INIS)

    Uchiyama, Junichi

    1998-01-01

    41 transparencies were presented on the subject of 'Reliability test for reactor internals rejuvenation technology'. The items presented give an introduction on the management of plant life in Japan and introduce the Nuclear Power Engineering Corporation (NUPEC). The question of what reliability tests for rejuvenation of reactor internals are is discussed in some detail and an outline of each test is given. Altogether six methods to rejuvenate reactor internals are presented, two of which have already been applied to actual plants. The presentation was supported by many detailed drawings and images

  12. Enhancing reliability of ultrasonic testing of welds of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Shcherbinskij, V.G.

    1981-01-01

    Results of investigation of factors influencing the reliability of manual ultrasonic testing of welded joints and weld deposited metal power-generating equipment are presented. Recommendations on the enhancing of reliability are given [ru

  13. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan

    Directory of Open Access Journals (Sweden)

    Moore AL

    2018-02-01

    Full Text Available Amy Lawson Moore, Terissa M Miller Gibson Institute of Cognitive Research, Colorado Springs, CO, USA Purpose: The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills.Methods: This study included 2,737 participants aged 5–85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test–retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement.Results: Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test–retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93.Conclusion: The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan. Keywords: testing, cognitive skills, memory, processing speed, visual processing, auditory processing

  14. First reliability test of a surface micromachined microengine using SHiMMeR

    Energy Technology Data Exchange (ETDEWEB)

    Tanner, D.M.; Smith, N.F.; Bowman, D.J. [and others

    1997-08-01

    The first-ever reliability stress test on surface micromachined microengines developed at Sandia National Laboratories (SNL) has been completed. We stressed 41 microengines at 36,000 RPM and inspected the functionality at 60 RPM. We have observed an infant mortality region, a region of low failure rate (useful life), and no signs of wearout in the data. The reliability data are presented and interpreted using standard reliability methods. Failure analysis results on the stressed microengines are presented. In our effort to study the reliability of MEMS, we need to observe the failures of large numbers of parts to determine the failure modes. To facilitate testing of large numbers of micromachines. The Sandia High Volume Measurement of Micromachine Reliability (SHiMMeR) system has computer controlled positioning and the capability to inspect moving parts. The development of this parallel testing system is discussed in detail.

  15. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    Science.gov (United States)

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing

  16. Reliability and accuracy of Cooper's test in male long distance runners

    Directory of Open Access Journals (Sweden)

    J.R. Alvero-Cruz

    2017-06-01

    Conclusions: All together, our results may confirm a good accuracy and reliability of Cooper's test in amateur long distance runners. Also, improvements or impairment lower than 52.2 m must not be associated with exercise training or retraining, since they are below the values of intra-subject reliability.

  17. Content validity and reliability of test of gross motor development in Chilean children

    Directory of Open Access Journals (Sweden)

    Marcelo Cano-Cappellacci

    2015-01-01

    Full Text Available ABSTRACT OBJECTIVE To validate a Spanish version of the Test of Gross Motor Development (TGMD-2 for the Chilean population. METHODS Descriptive, transversal, non-experimental validity and reliability study. Four translators, three experts and 92 Chilean children, from five to 10 years, students from a primary school in Santiago, Chile, have participated. The Committee of Experts has carried out translation, back-translation and revision processes to determine the translinguistic equivalence and content validity of the test, using the content validity index in 2013. In addition, a pilot implementation was achieved to determine test reliability in Spanish, by using the intraclass correlation coefficient and Bland-Altman method. We evaluated whether the results presented significant differences by replacing the bat with a racket, using T-test. RESULTS We obtained a content validity index higher than 0.80 for language clarity and relevance of the TGMD-2 for children. There were significant differences in the object control subtest when comparing the results with bat and racket. The intraclass correlation coefficient for reliability inter-rater, intra-rater and test-retest reliability was greater than 0.80 in all cases. CONCLUSIONS The TGMD-2 has appropriate content validity to be applied in the Chilean population. The reliability of this test is within the appropriate parameters and its use could be recommended in this population after the establishment of normative data, setting a further precedent for the validation in other Latin American countries.

  18. Influences on and Limitations of Classical Test Theory Reliability Estimates.

    Science.gov (United States)

    Arnold, Margery E.

    It is incorrect to say "the test is reliable" because reliability is a function not only of the test itself, but of many factors. The present paper explains how different factors affect classical reliability estimates such as test-retest, interrater, internal consistency, and equivalent forms coefficients. Furthermore, the limits of classical test…

  19. A COMPUTERIZED DIAGNOSTIC COMPLEX FOR RELIABILITY TESTING OF ELECTRIC MACHINES

    Directory of Open Access Journals (Sweden)

    O.О. Somka

    2015-06-01

    Full Text Available Purpose. To develop a diagnostic complex meeting the criteria and requirements for carrying out accelerated reliability test and realizing the basic modes of electric machines operation and performance of the posed problems necessary in the process of such test. Methodology. To determine and forecast the indices of electric machines reliability in accordance with the statistic data of repair plants we have conditionally divided them into structural parts that are most likely to fail. We have preliminarily assessed the state of each of these parts, which includes revelation of faults and deviations of technical and geometric parameters. We have determined the analyzed electric machine controlled parameters used for assessment of quantitative characteristics of reliability of these parts and electric machines on the whole. Results. As a result of the research, we have substantiated the structure of a computerized complex for electric machines reliability test. It allows us to change thermal and vibration actions without violation of the physics of the processes of aging and wearing of the basic structural parts and elements material. The above mentioned makes it possible to considerably reduce time spent on carrying out electric machines reliability tests and improve trustworthiness of the data obtained as a result of their performance. Originality. A special feature of determination of the controlled parameters consists in removal of vibration components in the idle mode and after disconnection of the analyzed electric machine from the power supply with the aim of singling out the vibration electromagnetic component, fixing the degree of sparking and bend of the shaft by means of phototechnique and local determination of structural parts temperature provided by corresponding location of thermal sensors. Practical value. We have offered a scheme of location of thermal and vibration sensors, which allows improvement of parameters measuring accuracy

  20. Test-retest reliability of the Work Ability Index questionnaire

    NARCIS (Netherlands)

    de Zwart, B. C. H.; Frings-Dresen, M. H. W.; Van Duivenbooden, J. C.

    2002-01-01

    The goal of the study was to assess the test-retest reliability of the Work Ability Index (WAI) questionnaire. Reliability was tested using a test-retest design with a 4 week interval between measurements. Valid data were collected among 97 elderly construction workers aged 40 years and older. We

  1. The Test-Retest Reliability of New Generation Power Indices of Wingate All-Out Test

    Directory of Open Access Journals (Sweden)

    Ozgur Ozkaya

    2018-04-01

    Full Text Available Although reliability correlations of traditional power indices of the Wingate test have been well documented, no study has analyzed new generation power indices based on milliseconds obtained from a Peak Bike. The purpose of this study was to investigate the retest reliability of new generation power indices. Thirty-two well-trained male athletes who were specialized in basketball, football, tennis, or track and field volunteered to take part in the study (age: 24.3 ± 2.2 years; body mass: 77 ± 8.3 kg; height: 180.3 ± 6.3 cm. Participants performed two Wingate all-out sessions on two separate days. Intra-class correlation coefficient (ICC, standard error measurement (SEM, smallest real differences (SRD and coefficient of variation (CV scores were analyzed based on the test and retest data. Reliability results of traditional power indices calculated based on 5-s means such as peak power, average power, power drop, and fatigue index ratio were similar with the previous findings in literature (ICC ≥ 0.94; CV ≤ 2.8%; SEM ≤ 12.28; SRD% ≤ 7.7%. New generation power indices such as peak power, average power, lowest power, power drop, fatigue index, power decline, maximum speed as rpm, and amount of total energy expenditure demonstrated high reliability (ICC ≥ 0.94; CV ≤ 4.3%; SEM ≤ 10.36; SRD% ≤ 8.8%. Time to peak power, time at maximum speed, and power at maximum speed showed a moderate level of reliability (ICC ≥ 0.73; CV ≤ 8.9%; SEM ≤ 63.01; SRD% ≤ 22.4%. The results of this study indicate that reliability correlations and SRD% of new generation power and fatigue-related indices are similar with traditional 5-s means. However, new time-related indices are very sensitive and moderately reliable.

  2. NASA reliability preferred practices for design and test

    Science.gov (United States)

    1991-01-01

    Given here is a manual that was produced to communicate within the aerospace community design practices that have contributed to NASA mission success. The information represents the best technical advice that NASA has to offer on reliability design and test practices. Topics covered include reliability practices, including design criteria, test procedures, and analytical techniques that have been applied to previous space flight programs; and reliability guidelines, including techniques currently applied to space flight projects, where sufficient information exists to certify that the technique will contribute to mission success.

  3. Test-Retest Reliability of the Salutogenic Wellness Promotion Scale (SWPS)

    Science.gov (United States)

    Anderson, L. M.; Moore, J. B.; Hayden, B. M.; Becker, C. M.

    2014-01-01

    Objective: This study examined the temporal stability (i.e. test-retest reliability) of the Salutogenic Wellness Promotion Scale (SWPS) using intraclass correlation coefficients (ICC). Current intraclass results were also compared to previously published interclass correlations to support the use of the intraclass method for test-retest…

  4. Test-retest reliability of the Danish Adult Reading Test in patients with comorbid psychosis and cannabis-use disorder

    DEFF Research Database (Denmark)

    Hjorthøj, Carsten Rygaard; Vesterager, Lone; Nordentoft, Merete

    2013-01-01

    Background: The New Adult Reading Test is a common instrument for assessing pre-morbid IQ for patients with, for instance, schizophrenia. However, test-retest reliability has not been established for patients dually diagnosed with psychosis and substance use disorder. Furthermore, test......-retest reliability of the Danish adaptation has never been established in any population. Aims: To determine the test-retest reliability of the Danish Adult Reading Test (DART) (adapted from the National Adult Reading Test, NART) for patients dually diagnosed with psychosis and cannabis-use disorder. Methods......: This was a secondary analysis of the CapOpus randomized trial. As part of the trial, 103 patients were randomized, and completed the DART up to three times. Pearson's r and pairwise t-tests were calculated. Results: DART score was independent of randomization, cannabis-use frequency and psychopathology. Scores...

  5. Reliability of candida skin test in the evaluation of T-cell function in ...

    African Journals Online (AJOL)

    Background: Both standardized and non-standardized candida skin tests are used in clinical practice for functional in-vivo assessment of cellular immunity with variable results and are considered not reliable under the age of 1 year. We sought to investigate the reliability of using manually prepared candida intradermal test ...

  6. Test rig overview for validation and reliability testing of shutdown system software

    International Nuclear Information System (INIS)

    Zhao, M.; McDonald, A.; Dick, P.

    2007-01-01

    The test rig for Validation and Reliability Testing of shutdown system software has been upgraded from the AECL Windows-based test rig previously used for CANDU6 stations. It includes a Virtual Trip Computer, which is a software simulation of the functional specification of the trip computer, and a real-time trip computer simulator in a separate chassis, which is used during the preparation of trip computer test cases before the actual trip computers are available. This allows preparation work for Validation and Reliability Testing to be performed in advance of delivery of actual trip computers to maintain a project schedule. (author)

  7. Reliability of Maximal Strength Testing in Novice Weightlifters

    Science.gov (United States)

    Loehr, James A.; Lee, Stuart M. C.; Feiveson, Alan H.; Ploutz-Snyder, Lori L.

    2009-01-01

    The one repetition maximum (1RM) is a criterion measure of muscle strength. However, the reliability of 1RM testing in novice subjects has received little attention. Understanding this information is crucial to accurately interpret changes in muscle strength. To evaluate the test-retest reliability of a squat (SQ), heel raise (HR), and deadlift (DL) 1RM in novice subjects. Twenty healthy males (31 plus or minus 5 y, 179.1 plus or minus 6.1 cm, 81.4 plus or minus 10.6 kg) with no weight training experience in the previous six months participated in four 1RM testing sessions, with each session separated by 5-7 days. SQ and HR 1RM were conducted using a smith machine; DL 1RM was assessed using free weights. Session 1 was considered a familiarization and was not included in the statistical analyses. Repeated measures analysis of variance with Tukey fs post-hoc tests were used to detect between-session differences in 1RM (p.0.05). Test-retest reliability was evaluated by intraclass correlation coefficients (ICC). During Session 2, the SQ and DL 1RM (SQ: 90.2 }4.3, DL: 75.9 }3.3 kg) were less than Session 3 (SQ: 95.3 }4.1, DL: 81.5 plus or minus 3.5 kg) and Session 4 (SQ: 96.6 }4.0, DL: 82.4 }3.9 kg), but there were no differences between Session 3 and Session 4. HR 1RM measured during Session 2 (150.1 }3.7 kg) and Session 3 (152.5 }3.9 kg) were not different from one another, but both were less than Session 4 (157.5 }3.8 kg). The reliability (ICC) of 1RM measures for Sessions 2-4 were 0.88, 0.83, and 0.87, for SQ, HR, and DL, respectively. When considering only Sessions 3 and 4, the reliability was 0.93, 0.91, and 0.86 for SQ, HR, and DL, respectively. One familiarization session and 2 test sessions (for SQ and DL) were required to obtain excellent reliability (ICC greater than or equal to 0.90) in 1RM values with novice subjects. We were unable to attain this level of reliability following 3 HR testing sessions therefore additional sessions may be required to obtain an

  8. Operational reliability testing of FBR fuel in EBR-II

    International Nuclear Information System (INIS)

    Asaga, Takeo; Ukai, Shigeharu; Nomura, Shigeo; Shikakura, Sakae

    1991-01-01

    The operational reliability testing of FBR fuel has been conducting in EBR-II as a DOE/PNC collaboration program. This paper reviews the achieved summary of Phase-I test as well as outline of progressing Phase-II test. In Phase-I test, the reliability of FBR fuel pins including 'MONJU' fuel was demonstrated at the event of operational transient. Continued operation of the failed pins was also shown to be feasible without affecting the plant operation. The objectives of the Phase-II test is to extend the data base relating with the operational reliability for long life fuel, and to supply the highly quantitative evaluation. The valuable insight obtained in Phase-II test are considerably expected to be useful toward the achievement of commercial FBR. (author)

  9. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan.

    Science.gov (United States)

    Moore, Amy Lawson; Miller, Terissa M

    2018-01-01

    The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.

  10. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. [Reliability for detection of developmental problems using the semaphore from the Child Development Evaluation test: Is a yellow result different from a red result?

    Science.gov (United States)

    Rizzoli-Córdoba, Antonio; Ortega-Ríosvelasco, Fernando; Villasís-Keever, Miguel Ángel; Pizarro-Castellanos, Mariel; Buenrostro-Márquez, Guillermo; Aceves-Villagrán, Daniel; O'Shea-Cuevas, Gabriel; Muñoz-Hernández, Onofre

    The Child Development Evaluation (CDE) is a screening tool designed and validated in Mexico for detecting developmental problems. The result is expressed through a semaphore. In the CDE test, both yellow and red results are considered positive, although a different intervention is proposed for each. The aim of this work was to evaluate the reliability of the CDE test to discriminate between children with yellow/red result based on the developmental domain quotient (DDQ) obtained through the Battelle Development Inventory, 2nd edition (in Spanish) (BDI-2). The information was obtained for the study from the validation. Children with a normal (green) result in the CDE were excluded. Two different cut-off points of the DDQ were used (BDI-2): social: 20.1% vs. 28.9%; and adaptive: 6.9% vs. 20.4%. The semaphore result yellow/red allows identifying different magnitudes of delay in developmental domains or subdomains, supporting the recommendation of different interventions for each one. Copyright © 2014 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  12. Standardization, Validity and Reliability Study of Gülhane Aphasia Test-2 (GAT-2

    Directory of Open Access Journals (Sweden)

    İlknur Maviş

    2007-04-01

    Full Text Available OBJECTIVE: Gülhane Aphasia Test-2 (GAT-2 has been developed to show the presence of a language disorder ‘aphasia’ and to give the clinician implications for the accompanying speech disorders such as apraxia and dysarthria. OBJECTIVE: The aim of the study was to report standardization, validity and reliability study of GAT-2. METHODS: : 10 healthy individuals were tested initially for the pilot study. 134 healthy individual was included to the standardization study and 30 individuals with aphasia and 11 individuals with right brain injury was included to the validation study. The inter group GAT-2 score differentiations and the effects of age, years of education, sex variances were observed. GAT-2 cut-off scores were calculated by the scores of healthy individuals. GAT-2 test-retest reliability and inter-observer reliability was calculated. RESULTS: Healthy individuals’ GAT-2 scores were significantly different from the GAT-2 scores of aphasic patients, but not from right brain injured patients’. Healthy individuals’ GAT-2 scores were not affected from the sex, age variances but from years of education, so cut-off scores were calculated by this variance. GAT-2 scores of aphasic patients were not affected from age, sex and years of education. Test-retest and inter-observer reliability and internal consistency results showed that GAT-2 is a highly reliable aphasia screening test. CONCLUSION: GAT-2 was found to be a standardized, highly reliable and a valid aphasia test for Turkish stroke patients with aphasia

  13. Optimal number of tests to achieve and validate product reliability

    International Nuclear Information System (INIS)

    Ahmed, Hussam; Chateauneuf, Alaa

    2014-01-01

    The reliability validation of engineering products and systems is mandatory for choosing the best cost-effective design among a series of alternatives. Decisions at early design stages have a large effect on the overall life cycle performance and cost of products. In this paper, an optimization-based formulation is proposed by coupling the costs of product design and validation testing, in order to ensure the product reliability with the minimum number of tests. This formulation addresses the question about the number of tests to be specified through reliability demonstration necessary to validate the product under appropriate confidence level. The proposed formulation takes into account the product cost, the failure cost and the testing cost. The optimization problem can be considered as a decision making system according to the hierarchy of structural reliability measures. The numerical examples show the interest of coupling design and testing parameters. - Highlights: • Coupled formulation for design and testing costs, with lifetime degradation. • Cost-effective testing optimization to achieve reliability target. • Solution procedure for nested aleatoric and epistemic variable spaces

  14. Test-retest and interrater reliability of the functional lower extremity evaluation.

    Science.gov (United States)

    Haitz, Karyn; Shultz, Rebecca; Hodgins, Melissa; Matheson, Gordon O

    2014-12-01

    Repeated-measures clinical measurement reliability study. To establish the reliability and face validity of the Functional Lower Extremity Evaluation (FLEE). The FLEE is a 45-minute battery of 8 standardized functional performance tests that measures 3 components of lower extremity function: control, power, and endurance. The reliability and normative values for the FLEE in healthy athletes are unknown. A face validity survey for the FLEE was sent to sports medicine personnel to evaluate the level of importance and frequency of clinical usage of each test included in the FLEE. The FLEE was then administered and rated for 40 uninjured athletes. To assess test-retest reliability, each athlete was tested twice, 1 week apart, by the same rater. To assess interrater reliability, 3 raters scored each athlete during 1 of the testing sessions. Intraclass correlation coefficients were used to assess the test-retest and interrater reliability of each of the FLEE tests. In the face validity survey, the FLEE tests were rated as highly important by 58% to 71% of respondents but frequently used by only 26% to 45% of respondents. Interrater reliability intraclass correlation coefficients ranged from 0.83 to 1.00, and test-retest reliability ranged from 0.71 to 0.95. The FLEE tests are considered clinically important for assessing lower extremity function by sports medicine personnel but are underused. The FLEE also is a reliable assessment tool. Future studies are required to determine if use of the FLEE to make return-to-play decisions may reduce reinjury rates.

  15. A REVIEW OF SINGLE SPECIES TOXICITY TESTS: ARE THE TESTS RELIABLE PREDICTORS OF AQUATIC ECOSYSTEM COMMUNITY RESPONSES?

    Science.gov (United States)

    This document provides a comprehensive review to evaluate the reliability of indicator species toxicity test results in predicting aquatic ecosystem impacts, also called the ecological relevance of laboratory single species toxicity tests.

  16. Absolute and Relative Reliability of the Timed 'Up & Go' Test and '30second Chair-Stand' Test in Hospitalised Patients with Stroke

    DEFF Research Database (Denmark)

    Lyders Johansen, Katrine; Derby Stistrup, Rikke; Skibdal Schjøtt, Camilla

    2016-01-01

    OBJECTIVE: The timed 'Up & Go' test and '30second Chair-Stand' test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability...... of both tests in patients admitted to an acute stroke unit. METHODS: Sixty-two patients (men, n = 41) attended two test sessions separated by a one hours rest. Intraclass correlation coefficients (ICC2,1) were calculated to assess relative reliability. Absolute reliability was expressed as Standard Error...... of Measurement (with 95% certainty-SEM95) and Smallest Real Difference (SRD) and as percentage of their respective means if heteroscedasticity was observed in Bland Altman plots (SEM95% and SRD%). RESULTS: ICC values for interrater reliability were 0.97 and 0.99 for the timed 'Up & Go' test and 0.88 and 0...

  17. Inter-rater and intra-rater reliability of a movement control test in shoulder.

    Science.gov (United States)

    Rajasekar, S; Bangera, Rakshith K; Sekaran, Padmanaban

    2017-07-01

    Movement faults are commonly observed in patients with musculoskeletal pain. The Kinetic Medial Rotation Test (KMRT) is a movement control test used to identify movement faults of the scapula and gleno-humeral joints during arm movement. Objective tests such as the KMRT need to be reliable and valid for the results to be applied across different clinical settings and patient populations. The primary objective of the present study was to determine the intra-rater and inter-rater reliability of KMRT in subjects with and without shoulder pain. Sixty subjects were included in this study based on specific inclusion and exclusion criteria. Two musculoskeletal physiotherapists with different levels of clinical experience performed the tests. The intra-rater reliability was tested in twenty asymptomatic subjects by a single assessor at two week intervals. An equal number of subjects with and without shoulder pain were tested by both the assessors to determine the inter-rater reliability. Both components of the KMRT, the Gleno- Humeral Anterior Translation (GHAT) and the Scapular Forward Tilt (SCFT) were tested. The Kappa values for inter-rater reliability of the GHAT and SCFT were K = 0.68 & K = 0.65 respectively in subjects with shoulder pain. In asymptomatic subjects, the inter-rater reliability of GHAT was K = 0.61 and SCFT was K = 0.85. Intra-rater reliability ranged from K = 0.66 for GHAT to K = 0.87 for SCFT. Our study found substantial agreement in inter-rater reliability of KMRT in subjects with shoulder pain, whereas substantial to near perfect agreement was found in intra-rater and inter-rater reliability of KMRT in subjects without shoulder pain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Human Reliability Data Bank: evaluation results

    International Nuclear Information System (INIS)

    Comer, M.K.; Donovan, M.D.; Gaddy, C.D.

    1985-01-01

    The US Nuclear Regulatory Commission (NRC), Sandia National Laboratories (SNL), and General Physics Corporation are conducting a research program to determine the practicality, acceptability, and usefulness of a Human Reliability Data Bank for nuclear power industry probabilistic risk assessment (PRA). As part of this program, a survey was conducted of existing human reliability data banks from other industries, and a detailed concept of a Data Bank for the nuclear industry was developed. Subsequently, a detailed specification for implementing the Data Bank was developed. An evaluation of this specification was conducted and is described in this report. The evaluation tested data treatment, storage, and retrieval using the Data Bank structure, as modified from NUREG/CR-2744, and detailed procedures for data processing and retrieval, developed prior to this evaluation and documented in the test specification. The evaluation consisted of an Operability Demonstration and Evaluation of the data processing procedures, a Data Retrieval Demonstration and Evaluation, a Retrospective Analysis that included a survey of organizations currently operating data banks for the nuclear power industry, and an Internal Analysis of the current Data Bank System

  19. Reliability of non-destructive testing methods

    International Nuclear Information System (INIS)

    Broekhoven, M.J.G.

    1988-01-01

    This contribution regards the results of an evaluation of the reliability of radiography (X-rays and gamma-rays), manual-, and mechanized/automated ultrasonic examination by generally accepted codes/rules, with respect to detection, characterization and sizing/localization of defects. The evaluation is based on the results of examinations, by a number of teams, of 30 test plates, 30 and 50 mm thickness, containing V,U, X and K-shaped welds each containing several types of imperfections (211) in total) typical for steel arc fusion welding, such as porosity, inclusions, lack of fusion or penetration and cracks. Besides, some results are presented obtained from research on advanced UT-techniques, viz. the time-of-flight-diffraction and flaw-tip deflection technique. (author)

  20. Reliability of non-destructive testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Broekhoven, M J.G. [Ministry of Social Affairs, (Netherlands)

    1988-12-31

    This contribution regards the results of an evaluation of the reliability of radiography (X-rays and gamma-rays), manual-, and mechanized/automated ultrasonic examination by generally accepted codes/rules, with respect to detection, characterization and sizing/localization of defects. The evaluation is based on the results of examinations, by a number of teams, of 30 test plates, 30 and 50 mm thickness, containing V,U, X and K-shaped welds each containing several types of imperfections (211) in total) typical for steel arc fusion welding, such as porosity, inclusions, lack of fusion or penetration and cracks. Besides, some results are presented obtained from research on advanced UT-techniques, viz. the time-of-flight-diffraction and flaw-tip deflection technique. (author). 4 refs.

  1. FFTF [Fast Flux Test Facility] reactor shutdown system reliability reevaluation

    International Nuclear Information System (INIS)

    Pierce, B.F.

    1986-07-01

    The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations

  2. Validity and Reliability Testing of an e-learning Questionnaire for Chemistry Instruction

    Science.gov (United States)

    Guspatni, G.; Kurniawati, Y.

    2018-04-01

    The aim of this paper is to examine validity and reliability of a questionnaire used to evaluate e-learning implementation in chemistry instruction. 48 questionnaires were filled in by students who had studied chemistry through e-learning system. The questionnaire consisted of 20 indicators evaluating students’ perception on using e-learning. Parametric testing was done as data were assumed to follow normal distribution. Item validity of the questionnaire was examined through item-total correlation using Pearson’s formula while its reliability was assessed with Cronbach’s alpha formula. Moreover, convergent validity was assessed to see whether indicators building a factor had theoretically the same underlying construct. The result of validity testing revealed 19 valid indicators while the result of reliability testing revealed Cronbach’s alpha value of .886. The result of factor analysis showed that questionnaire consisted of five factors, and each of them had indicators building the same construct. This article shows the importance of factor analysis to get a construct valid questionnaire before it is used as research instrument.

  3. Development of an Agility Test for Badminton Players and Assessment of Its Validity and Test-Retest Reliability.

    Science.gov (United States)

    Loureiro, Luiz de França Bahia; de Freitas, Paulo Barbosa

    2016-04-01

    Badminton requires open and fast actions toward the shuttlecock, but there is no specific agility test for badminton players with specific movements. To develop an agility test that simultaneously assesses perception and motor capacity and examine the test's concurrent and construct validity and its test-retest reliability. The Badcamp agility test consists of running as fast as possible to 6 targets placed on the corners and middle points of a rectangular area (5.6 × 4.2 m) from the start position located in the center of it, following visual stimuli presented in a luminous panel. The authors recruited 43 badminton players (17-32 y old) to evaluate concurrent (with shuttle-run agility test--SRAT) and construct validity and test-retest reliability. Results revealed that Badcamp presents concurrent and construct validity, as its performance is strongly related to SRAT (ρ = 0.83, P < .001), with performance of experts being better than nonexpert players (P < .01). In addition, Badcamp is reliable, as no difference (P = .07) and a high intraclass correlation (ICC = .93) were found in the performance of the players on 2 different occasions. The findings indicate that Badcamp is an effective, valid, and reliable tool to measure agility, allowing coaches and athletic trainers to evaluate players' athletic condition and training effectiveness and possibly detect talented individuals in this sport.

  4. Test–re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females

    OpenAIRE

    Chris Beardsley; Tim Egerton; Brendon Skinner

    2016-01-01

    Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females.\\ud \\ud Method. The inter-rater reliability and test–re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart.\\ud \\ud Results. For measuring pel...

  5. Test-retest reliability and practice effects of the Wechsler Memory Scale-III.

    Science.gov (United States)

    Lo, Ada H Y; Humphreys, Michael; Byrne, Gerard J; Pachana, Nancy A

    2012-09-01

    Although serial administration of cognitive tests is increasingly common, there is a paucity of research on test-retest reliabilities and practice effects, both of which are important for evaluating changes in functioning. Reliability is generally conceptualized as involving short-lasting changes in performance. However, when repeated testing occurs over a period of years, there will be some longer lasting effects. The implications of these longer lasting effects and practice effects on reliability were examined in the context of repeated administrations of the Wechsler Memory Scale-III in 339 community-dwelling women aged 40-79 years over 2 to 7 years. The results showed that Logical Memory and Verbal Paired Associates subtests were consistently the most reliable subtests across the age cohorts. The magnitude of practice effects varied as a function of subtests and age. The largest practice effects were found in the youngest age cohort, especially on the Faces, Logical Memory, and Verbal Paired Associates subtests. ©2012 The British Psychological Society.

  6. Increasing the reliability of the fluid/crystallized difference score from the Kaufman Adolescent and Adult Intelligence Test with reliable component analysis.

    Science.gov (United States)

    Caruso, J C

    2001-06-01

    The unreliability of difference scores is a well documented phenomenon in the social sciences and has led researchers and practitioners to interpret differences cautiously, if at all. In the case of the Kaufman Adult and Adolescent Intelligence Test (KAIT), the unreliability of the difference between the Fluid IQ and the Crystallized IQ is due to the high correlation between the two scales. The consequences of the lack of precision with which differences are identified are wide confidence intervals and unpowerful significance tests (i.e., large differences are required to be declared statistically significant). Reliable component analysis (RCA) was performed on the subtests of the KAIT in order to address these problems. RCA is a new data reduction technique that results in uncorrelated component scores with maximum proportions of reliable variance. Results indicate that the scores defined by RCA have discriminant and convergent validity (with respect to the equally weighted scores) and that differences between the scores, derived from a single testing session, were more reliable than differences derived from equal weighting for each age group (11-14 years, 15-34 years, 35-85+ years). This reliability advantage results in narrower confidence intervals around difference scores and smaller differences required for statistical significance.

  7. Data mining-based coefficient of influence factors optimization of test paper reliability

    Science.gov (United States)

    Xu, Peiyao; Jiang, Huiping; Wei, Jieyao

    2018-05-01

    Test is a significant part of the teaching process. It demonstrates the final outcome of school teaching through teachers' teaching level and students' scores. The analysis of test paper is a complex operation that has the characteristics of non-linear relation in the length of the paper, time duration and the degree of difficulty. It is therefore difficult to optimize the coefficient of influence factors under different conditions in order to get text papers with clearly higher reliability with general methods [1]. With data mining techniques like Support Vector Regression (SVR) and Genetic Algorithm (GA), we can model the test paper analysis and optimize the coefficient of impact factors for higher reliability. It's easy to find that the combination of SVR and GA can get an effective advance in reliability from the test results. The optimal coefficient of influence factors optimization has a practicability in actual application, and the whole optimizing operation can offer model basis for test paper analysis.

  8. Validity, Reliability and Standardization Study of the Language Assessment Test for Aphasia

    Directory of Open Access Journals (Sweden)

    Bülent Toğram

    2012-09-01

    Full Text Available OBJECTIVE: Aphasia assessment is the first step towards a well- founded language therapy. Language tests need to consider cultural as well as typological linguistic aspects of a given language. This study was designed to determine the standardization, validity and reliability of Language Assessment Test for Aphasia, which consists of eight subtests including spontaneous speech and language, auditory comprehension, repetition, naming, reading, grammar, speech acts, and writing. METHODS: The test was administered to 282 healthy participants and 92 aphasic participants in age, education and gender matched groups. The validity study of the test was investigated with analysis of content, structure and criterion-related validity. For reliability of the test, the analysis of internal consistency, stability and equivalence reliability was conducted. The influence of variables on healhty participants’ sub-test scores, test score and language score was examined. According to significant differences, norms and cut-off scores based on language score were determined. RESULTS: The group with aphasia performed highly lower than healthy participants on subtest, test and language scores. The test scores of healthy group were mostly affected by age and educational level but not affected by gender. According to significant differences, age and educational level for both groups were determined. Considering age and educational levels, the reference values for the cut-off scores were presented. CONCLUSION: The test was found to be a highly reliable and valid aphasia test for Turkish- speaking aphasic patients either in Turkey or other Turkish communities around the world

  9. The Comprehensive Snack Parenting Questionnaire (CSPQ: Development and Test-Retest Reliability

    Directory of Open Access Journals (Sweden)

    Dorus W. M. Gevers

    2018-04-01

    Full Text Available The narrow focus of existing food parenting instruments led us to develop a food parenting practices instrument measuring the full range of food practices constructs with a focus on snacking behavior. We present the development of the questionnaire and our research on the test-retest reliability. The developed Comprehensive Snack Parenting Questionnaire (CSPQ covers 21 constructs. Test-retest reliability was assessed by calculating intra class correlation coefficients and percentage agreement after two administrations of the CSPQ among a sample of 66 Dutch parents. Test-retest reliability analysis revealed acceptable intra class correlation coefficients (≥0.41 or agreement scores (≥0.60 for all items. These results, together with earlier work, suggest sufficient psychometric characteristics. The comprehensive, but brief CSPQ opens up chances for highly essential but unstudied research questions to understand and predict children’s snack intake. Example applications include studying the interactional nature of food parenting practices or interactions of food parenting with general parenting or child characteristics.

  10. Automation of testing the metrological reliability of nondestructive control systems

    International Nuclear Information System (INIS)

    Zhukov, Yu.A.; Isakov, V.B.; Karlov, Yu.K.; Kovalevskij, Yu.A.

    1987-01-01

    Opportunities of microcomputers are used to solve the problem of testing control-measuring systems. Besides the main program the program of data processing when characterizing the nondestructive control systems is written in the microcomputer. The program includes two modules. The first module contains tests-programs, by which accuracy of functional elements of the microcomputer and interface elements with issuing a message to the operator on readiness of the elements for operation and failure of a certain element are determined. The second module includes: calculational programs when determining metrological reliability of measuring channel reliability, a calculational subprogram for random statistical measuring error, time instability and ''dead time''. Automation of testing metrological reliability of the nondestructive control systems increases reliability of determining metrological parameters and reduces time of system testing

  11. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    Science.gov (United States)

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  12. Test-retest reliability of a balance testing protocol with external perturbations in young healthy adults.

    Science.gov (United States)

    Robbins, Shawn M; Caplan, Ryan M; Aponte, Daniel I; St-Onge, Nancy

    2017-10-01

    External perturbations are utilized to challenge balance and mimic realistic balance threats in patient populations. The reliability of such protocols has not been established. The purpose was to examine test-retest reliability of balance testing with external perturbations. Healthy adults (n=34; mean age 23 years) underwent balance testing over two visits. Participants completed ten balance conditions in which the following parameters were combined: perturbation or non-perturbation, single or double leg, and eyes open or closed. Three trials were collected for each condition. Data were collected on a force plate and external perturbations were applied by translating the plate. Force plate center of pressure (CoP) data were summarized using 13 different CoP measures. Test-retest reliability was examined using intraclass correlation coefficients (ICC) and Bland-Altman plots. CoP measures of total speed and excursion in both anterior-posterior and medial-lateral directions generally had acceptable ICC values for perturbation conditions (ICC=0.46 to 0.87); however, many other CoP measures (e.g. range, area of ellipse) had unacceptable test-retest reliability (ICCbalance testing protocols that include external perturbations should be made to improve test-retest reliability and diminish learning including more extensive participant training and increasing the number of trials. CoP measures that consider all data points (e.g. total speed) are more reliable than those that only consider a few data points. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Reliability Testing the Die-Attach of CPV Cell Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Bosco, N.; Sweet, C.; Kurtz, S.

    2011-02-01

    Results and progress are reported for a course of work to establish an efficient reliability test for the die-attach of CPV cell assemblies. Test vehicle design consists of a ~1 cm2 multijunction cell attached to a substrate via several processes. A thermal cycling sequence is developed in a test-to-failure protocol. Methods of detecting a failed or failing joint are prerequisite for this work; therefore both in-situ and non-destructive methods, including infrared imaging techniques, are being explored as a method to quickly detect non-ideal or failing bonds.

  14. Impact of Relationships between Test and Reference Animals and between Reference Animals on Reliability of Genomic Prediction

    DEFF Research Database (Denmark)

    Wu, Xiaoping; Lund, Mogens Sandø; Sun, Dongxiao

    This study investigated reliability of genomic prediction in various scenarios with regard to relationship between test and reference animals and between animals within the reference population. Different reference populations were generated from EuroGenomics data and 1288 Nordic Holstein bulls...... as a common test population. A GBLUP model and a Bayesian mixture model were applied to predict Genomic breeding values for bulls in the test data. Result showed that a closer relationship between test and reference animals led to a higher reliability, while a closer relationship between reference animal...... resulted in a lower reliability. Therefore, the design of reference population is important for improving the reliability of genomic prediction. With regard to model, the Bayesian mixture model in general led to slightly a higher reliability of genomic prediction than the GBLUP model...

  15. Final report : testing and evaluation for solar hot water reliability.

    Energy Technology Data Exchange (ETDEWEB)

    Caudell, Thomas P. (University of New Mexico, Albuquerque, NM); He, Hongbo (University of New Mexico, Albuquerque, NM); Menicucci, David F. (Building Specialists, Inc., Albuquerque, NM); Mammoli, Andrea A. (University of New Mexico, Albuquerque, NM); Burch, Jay (National Renewable Energy Laboratory, Golden CO)

    2011-07-01

    Solar hot water (SHW) systems are being installed by the thousands. Tax credits and utility rebate programs are spurring this burgeoning market. However, the reliability of these systems is virtually unknown. Recent work by Sandia National Laboratories (SNL) has shown that few data exist to quantify the mean time to failure of these systems. However, there is keen interest in developing new techniques to measure SHW reliability, particularly among utilities that use ratepayer money to pay the rebates. This document reports on an effort to develop and test new, simplified techniques to directly measure the state of health of fielded SHW systems. One approach was developed by the National Renewable Energy Laboratory (NREL) and is based on the idea that the performance of the solar storage tank can reliably indicate the operational status of the SHW systems. Another approach, developed by the University of New Mexico (UNM), uses adaptive resonance theory, a type of neural network, to detect and predict failures. This method uses the same sensors that are normally used to control the SHW system. The NREL method uses two additional temperature sensors on the solar tank. The theories, development, application, and testing of both methods are described in the report. Testing was performed on the SHW Reliability Testbed at UNM, a highly instrumented SHW system developed jointly by SNL and UNM. The two methods were tested against a number of simulated failures. The results show that both methods show promise for inclusion in conventional SHW controllers, giving them advanced capability in detecting and predicting component failures.

  16. Reliability test: X-ray ring exit chambers crotch radiation absorbers. Final report

    International Nuclear Information System (INIS)

    Lynch, D.R.; Morgan, J.

    1999-01-01

    This report details the efforts by engineers at the National Synchrotron Light Source (NSLS) of Brookhaven National Laboratory (BNL) to evaluate the reliability of water-cooled radiation absorbers used in the NSLS X-ray ring. These absorbers are part of the 16 dipole vacuum chambers which comprise the arc sections of the ring. They are located at the intersections (crotch) of the beamline exit ports with the electron beam chamber, and are commonly referred to as crotches. The purpose of these efforts was to demonstrate the reliability of the crotches under operating conditions that the crotches will be subjected to over the entire expected life of the ring. The efforts described include engineering calculations, finite element analysis, conceptual design for a reliability test, test implementation and descriptions, results and conclusions related to these analyses and tests

  17. Forward lunge as a functional performance test in ACL deficient subjects: test-retest reliability

    DEFF Research Database (Denmark)

    Alkjaer, Tine; Henriksen, Marius; Dyhre-Poulsen, Poul

    2009-01-01

    The forward lunge movement may be used as a functional performance test of anterior cruciate ligament (ACL) deficient and reconstructed subjects. The purposes were 1) to determine the test-retest reliability of a forward lunge in healthy subjects and 2) to determine the required numbers...... of repetitions necessary to yield satisfactory reliability. Nineteen healthy subjects performed four trials of a forward lunge on two different days. The movement time, impulses of the ground reaction forces (IFz, IFy), knee joint kinematics and dynamics during the forward lunge were calculated. The relative...... reliability was determined by calculation of Intraclass Correlation Coefficients (ICC). The IFz, IFy and the positive work of the knee extensors showed excellent reliability (ICC >0.75). All other variables demonstrated acceptable reliability (0.4>ICCreliability increased when more than...

  18. Practice effects and test-re-test reliability of the Five Digit Test in patients with stroke over four serial assessments.

    Science.gov (United States)

    Chiu, En-Chi; Koh, Chia-Lin; Tsai, Chia-Yin; Lu, Wen-Shian; Sheu, Ching-Fan; Hsueh, I-Ping; Hsieh, Ching-Lin

    2014-01-01

    To investigate practice effect and test-re-test reliability of the Five Digit Test (FDT) over four serial assessments in patients with stroke. Single-group repeated measures design. Twenty-five patients with stroke were administered the FDT in four consecutive assessments every 2 weeks. The FDT contains four parts with five indices: 'basic measures of attention and processing speed', 'selective attention', 'alternating attention', 'ability of inhibition' and 'ability of switching'. The five indices of the FDT showed trivial-to-small practice effects (Cohen's d = 0.03-0.47) and moderate-to-excellent test-re-test reliability (intra-class correlation coefficient = 0.59-0.97). Practice effects of the five indices all appeared cumulative, but one index, 'basic measures of attention and processing speed', reached a plateau after the second assessment. The minimum and maximum values of the 90% confidence interval (CI) of reliable change index modified for practice (RCIp) for this index were [-17.6, 11.2]. One of five indices of the FDT reached a plateau, whose minimum and maximum values of the 90% CI RCIp are useful to determine whether the change in an individual's score is real. However, clinicians and researchers should be cautious when interpreting the test results of these four indices over repeated assessments.

  19. Reliability and Validity of the Inline Skating Skill Test

    Science.gov (United States)

    Radman, Ivan; Ruzic, Lana; Padovan, Viktoria; Cigrovski, Vjekoslav; Podnar, Hrvoje

    2016-01-01

    This study aimed to examine the reliability and validity of the inline skating skill test. Based on previous skating experience forty-two skaters (26 female and 16 male) were randomized into two groups (competitive level vs. recreational level). They performed the test four times, with a recovery time of 45 minutes between sessions. Prior to testing, the participants rated their skating skill using a scale from 1 to 10. The protocol included performance time measurement through a course, combining different skating techniques. Trivial changes in performance time between the repeated sessions were determined in both competitive females/males and recreational females/males (-1.7% [95% CI: -5.8–2.6%] – 2.2% [95% CI: 0.0–4.5%]). In all four subgroups, the skill test had a low mean within-individual variation (1.6% [95% CI: 1.2–2.4%] – 2.7% [95% CI: 2.1–4.0%]) and high mean inter-session correlation (ICC = 0.97 [95% CI: 0.92–0.99] – 0.99 [95% CI: 0.98–1.00]). The comparison of detected typical errors and smallest worthwhile changes (calculated as standard deviations × 0.2) revealed that the skill test was able to track changes in skaters’ performances. Competitive-level skaters needed shorter time (24.4–26.4%, all p skating skills in amateur competitive and recreational level skaters. Further studies are needed to evaluate the reproducibility of this skill test in different populations including elite inline skaters. Key points Study evaluated the reliability and construct validity of a newly developed inline skating skill test. Evaluated test is a first protocol designed to assess specific inline skating skill. Two groups of amateur skaters with different skating proficiency repeated the skill test in four separate occasions. The results suggest that evaluated test is reliable and valid to evaluate inline skating skill in amateur skaters. PMID:27803616

  20. The reliability of test results from simple test samples in predicting the fatigue performance of automotive components

    International Nuclear Information System (INIS)

    Fourlaris, G.; Ellwood, R.; Jones, T.B.

    2007-01-01

    The use of high strength steels (HSS) in automotive components is steadily increasing as automotive designers use modern steel grades to improve structural performance, reduce vehicle weight and enhance crash performance. Weight reduction can be achieved by substituting mild steel with a thinner gauge HSS, however, it must be ensured that no deterioration in performance including fatigue capability occurs. In this study, tests have been carried out to determine the effects that gauge and material strength have on the fatigue performance of a fusion welded automotive suspension arm. Current finite element (FE) modelling and fatigue prediction techniques have been evaluated to determine their reliability when used for thin strip steels. Results have shown the fatigue performance of welded components to be independent of the strength of the parent material for the steel grades studied, with material thickness and joining process the key features determining the fatigue performance. The correlation between the fatigue performance of simple welded samples under uniaxial, constant amplitude loading and complex components under biaxial in service road load data, has been shown to be unreliable. This study also indicates that with the application of modern technologies, such as tailor-welded blanks (TWB), significant weight savings can be achieved. This is demonstrated by a 19% weight reduction with no detrimental effect on the fatigue performance

  1. Users manual on database of the Piping Reliability Proving Tests at the Japan Atomic Energy Research Institute

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    Japan Atomic Energy Research Institute(JAERI) conducted Piping Reliability Proving Tests from 1975 to 1992 based upon the contracts between JAERI and Science and Technology Agency of Japan under the auspices of the special account law for electric power development promotion. The purposes of those tests are to prove the structural reliability of the primary cooling piping constituting a part of the pressure boundary in the water reactor power plants. The tests with large experimental facilities had ended already in 1990. After that piping reliability analysis by the probabilistic method followed until 1992. This report describes the users manual on databases about the test results using the large experimental facilities. Objectives of the piping reliability proving tests are to prove that the primary piping of the water reactor (1) be reliable throughout the service period, (2) have no possibility of rupture, (3) bring no detrimental influence on the surrounding instrumentations or equipments near the break location. The research activities using large scale piping test facilities are described. The present report does the database about the test results pairing the former report. With these two reports, all the feature of Piping Reliability Proving Tests is made clear. Briefings of the tests are described also written in Japanese or English. (author)

  2. Reliability of the Timed Up and Go test and Ten-Metre Timed Walk Test in Pregnant Women with Pelvic Girdle Pain.

    Science.gov (United States)

    Evensen, Natalie M; Kvåle, Alice; Braekken, Ingeborg H

    2015-09-01

    There is a lack of functional objective tests available to measure functional status in women with pelvic girdle pain (PGP). The purpose of this study was to establish test-retest and intertester reliability of the Timed Up and Go (TUG) test and Ten-metre Timed Walk Test (10mTWT) in pregnant women with PGP. A convenience sample of women was recruited over a 4-month period and tested on two occasions, 1 week apart to determine test-retest reliability. Intertester reliability was established between two assessors at the first testing session. Subjects were instructed to undertake the TUG and 10mTWT at maximum speed. One practise trial and two timed trials for each walking test was undertaken on Day 1 and one practise trial and one timed trial on Day 2. Seventeen women with PGP aged 31.1 years (SD [standard deviation] = 2.3) and 28.7 weeks pregnant (SD = 7.4) completed gait testing. Test-retest reliability using the intraclass correlation coefficient (ICC) was excellent for the TUG (0.88) and good for the 10mTWT (0.74). Intertester reliability was determined in the first 13 participants with excellent ICC values being found for both walking tests (TUG: 0.95; 10mTWT: 0.94). This study demonstrated that the TUG and 10mTWT undertaken at fast pace are reliable, objective functional tests in pregnant women with PGP. While both tests are suitable for use in the clinical and research settings, we would recommend the TUG given the findings of higher test-retest reliability and as this test requires less space and time to set up and score. Future studies in a larger sample size are warranted to confirm the results of this study. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Reliability and validity of a talent identification test battery for seated and standing Paralympic throws.

    Science.gov (United States)

    Spathis, Jemima Grace; Connick, Mark James; Beckman, Emma Maree; Newcombe, Peter Anthony; Tweedy, Sean Michael

    2015-01-01

    Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test-retest reliability. Talent identification test-retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland-Altman plots (Limits of Agreement). Spearman's correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.

  4. Validity and Reliability of the Arabic Token Test for Children

    Science.gov (United States)

    Alkhamra, Rana A.; Al-Jazi, Aya B.

    2016-01-01

    Background: The Token Test for Children (2nd edition) (TTFC) is a measure for assessing receptive language. In this study we describe the translation process, validity and reliability of the Arabic Token Test for Children (A-TTFC). Aims: The aim of this study is to translate, validate and establish the reliability of the Arabic Token Test for…

  5. Conceptualizing Essay Tests' Reliability and Validity: From Research to Theory

    Science.gov (United States)

    Badjadi, Nour El Imane

    2013-01-01

    The current paper on writing assessment surveys the literature on the reliability and validity of essay tests. The paper aims to examine the two concepts in relationship with essay testing as well as to provide a snapshot of the current understandings of the reliability and validity of essay tests as drawn in recent research studies. Bearing in…

  6. Construction of Valid and Reliable Test for Assessment of Students

    Science.gov (United States)

    Osadebe, P. U.

    2015-01-01

    The study was carried out to construct a valid and reliable test in Economics for secondary school students. Two research questions were drawn to guide the establishment of validity and reliability for the Economics Achievement Test (EAT). It is a multiple choice objective test of five options with 100 items. A sample of 1000 students was randomly…

  7. Inter-tester reliability of selected clinical tests for long-lasting temporomandibular disorders.

    Science.gov (United States)

    Julsvoll, Elisabeth Heggem; Vøllestad, Nina Køpke; Opseth, Gro; Robinson, Hilde Stendal

    2017-09-01

    Clinical tests used to examine patients with temporomandibular disorders vary in methodological quality, and some are not tested for reliability. The purpose of this cross-sectional study was to evaluate inter-tester reliability of clinical tests and a cluster of tests used to examine patients with long-lasting temporomandibular disorders. Forty patients with pain in the temporomandibular area treated by health-professionals were included. They were between 18-70 years, had 65 symptomatic (33 right/32 left) and 15 asymptomatic joints. Two manual therapists examined all participants with selected tests. Percentage agreement and the kappa coefficient ( k ) with 95% confidence interval (CI) were used to evaluate the tests with categorical outcomes. For tests with continuous outcomes, the relative inter-tester reliability was assessed by the intraclass-correlation-coefficient (ICC 3,1 , 95% CI) and the absolute reliability was calculated by the smallest detectable change (SDC). The best reliability among single tests was found for the dental stick test, the joint-sound test ( k  = 0.80-1.0) and range of mouth-opening (ICC 3,1 (95% CI) = 0.97 (0.95-0.98) and SDC = 4 mm). The reliability of cluster of tests was excellent with both four and five positive tests out of seven. The reliability was good to excellent for the clinical tests and the cluster of tests when performed by experienced therapists. The tests are feasible for use in the clinical setting. They require no advanced equipment and are easy to perform.

  8. Automatically generated acceptance test: A software reliability experiment

    Science.gov (United States)

    Protzel, Peter W.

    1988-01-01

    This study presents results of a software reliability experiment investigating the feasibility of a new error detection method. The method can be used as an acceptance test and is solely based on empirical data about the behavior of internal states of a program. The experimental design uses the existing environment of a multi-version experiment previously conducted at the NASA Langley Research Center, in which the launch interceptor problem is used as a model. This allows the controlled experimental investigation of versions with well-known single and multiple faults, and the availability of an oracle permits the determination of the error detection performance of the test. Fault interaction phenomena are observed that have an amplifying effect on the number of error occurrences. Preliminary results indicate that all faults examined so far are detected by the acceptance test. This shows promise for further investigations, and for the employment of this test method on other applications.

  9. MEMS Reliability: Infrastructure, Test Structures, Experiments, and Failure Modes

    Energy Technology Data Exchange (ETDEWEB)

    TANNER,DANELLE M.; SMITH,NORMAN F.; IRWIN,LLOYD W.; EATON,WILLIAM P.; HELGESEN,KAREN SUE; CLEMENT,J. JOSEPH; MILLER,WILLIAM M.; MILLER,SAMUEL L.; DUGGER,MICHAEL T.; WALRAVEN,JEREMY A.; PETERSON,KENNETH A.

    2000-01-01

    The burgeoning new technology of Micro-Electro-Mechanical Systems (MEMS) shows great promise in the weapons arena. We can now conceive of micro-gyros, micro-surety systems, and micro-navigators that are extremely small and inexpensive. Do we want to use this new technology in critical applications such as nuclear weapons? This question drove us to understand the reliability and failure mechanisms of silicon surface-micromachined MEMS. Development of a testing infrastructure was a crucial step to perform reliability experiments on MEMS devices and will be reported here. In addition, reliability test structures have been designed and characterized. Many experiments were performed to investigate failure modes and specifically those in different environments (humidity, temperature, shock, vibration, and storage). A predictive reliability model for wear of rubbing surfaces in microengines was developed. The root causes of failure for operating and non-operating MEMS are discussed. The major failure mechanism for operating MEMS was wear of the polysilicon rubbing surfaces. Reliability design rules for future MEMS devices are established.

  10. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    Science.gov (United States)

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which

  11. A New Tool for Nutrition App Quality Evaluation (AQEL): Development, Validation, and Reliability Testing.

    Science.gov (United States)

    DiFilippo, Kristen Nicole; Huang, Wenhao; Chapman-Novakofski, Karen M

    2017-10-27

    The extensive availability and increasing use of mobile apps for nutrition-based health interventions makes evaluation of the quality of these apps crucial for integration of apps into nutritional counseling. The goal of this research was the development, validation, and reliability testing of the app quality evaluation (AQEL) tool, an instrument for evaluating apps' educational quality and technical functionality. Items for evaluating app quality were adapted from website evaluations, with additional items added to evaluate the specific characteristics of apps, resulting in 79 initial items. Expert panels of nutrition and technology professionals and app users reviewed items for face and content validation. After recommended revisions, nutrition experts completed a second AQEL review to ensure clarity. On the basis of 150 sets of responses using the revised AQEL, principal component analysis was completed, reducing AQEL into 5 factors that underwent reliability testing, including internal consistency, split-half reliability, test-retest reliability, and interrater reliability (IRR). Two additional modifiable constructs for evaluating apps based on the age and needs of the target audience as selected by the evaluator were also tested for construct reliability. IRR testing using intraclass correlations (ICC) with all 7 constructs was conducted, with 15 dietitians evaluating one app. Development and validation resulted in the 51-item AQEL. These were reduced to 25 items in 5 factors after principal component analysis, plus 9 modifiable items in two constructs that were not included in principal component analysis. Internal consistency and split-half reliability of the following constructs derived from principal components analysis was good (Cronbach alpha >.80, Spearman-Brown coefficient >.80): behavior change potential, support of knowledge acquisition, app function, and skill development. App purpose split half-reliability was .65. Test-retest reliability showed no

  12. Impact on participation and autonomy: test of validity and reliability for older persons

    Directory of Open Access Journals (Sweden)

    Isabelle Ottenvall Hammar

    2014-10-01

    Full Text Available In research and healthcare it is important to measure older persons’ self-determination in order to improve their possibilities to decide for themselves in daily life. The questionnaire Impact on Participation and Autonomy (IPA assesses self-determination, but is not constructed for older persons. The aim of this study was to examine the validity and reliability of the IPA-S questionnaire for persons aged 70 years and older. The study was performed in two steps; first a validity test of the Swedish version of the questionnaire, IPA-S, followed by a reliability test-retest of an adjusted version. The validity was tested with focus groups and individual interviews on persons aged 77-88 years, and the reliability on persons aged 70-99 years. The validity test result showed that IPA-S is valid for older persons but it was too extensive and the phrasing of the items needed adjustments. The reliability test-retest on the adjusted questionnaire, IPA-Older persons (IPA-O, showed that 15 of 22 items had high agreement. IPA-O can be used to measure older persons’ self-determination in their care and rehabilitation.

  13. Test-retest and between-site reliability in a multicenter fMRI study.

    Science.gov (United States)

    Friedman, Lee; Stern, Hal; Brown, Gregory G; Mathalon, Daniel H; Turner, Jessica; Glover, Gary H; Gollub, Randy L; Lauriello, John; Lim, Kelvin O; Cannon, Tyrone; Greve, Douglas N; Bockholt, Henry Jeremy; Belger, Aysenil; Mueller, Bryon; Doty, Michael J; He, Jianchun; Wells, William; Smyth, Padhraic; Pieper, Steve; Kim, Seyoung; Kubicki, Marek; Vangel, Mark; Potkin, Steven G

    2008-08-01

    In the present report, estimates of test-retest and between-site reliability of fMRI assessments were produced in the context of a multicenter fMRI reliability study (FBIRN Phase 1, www.nbirn.net). Five subjects were scanned on 10 MRI scanners on two occasions. The fMRI task was a simple block design sensorimotor task. The impulse response functions to the stimulation block were derived using an FIR-deconvolution analysis with FMRISTAT. Six functionally-derived ROIs covering the visual, auditory and motor cortices, created from a prior analysis, were used. Two dependent variables were compared: percent signal change and contrast-to-noise-ratio. Reliability was assessed with intraclass correlation coefficients derived from a variance components analysis. Test-retest reliability was high, but initially, between-site reliability was low, indicating a strong contribution from site and site-by-subject variance. However, a number of factors that can markedly improve between-site reliability were uncovered, including increasing the size of the ROIs, adjusting for smoothness differences, and inclusion of additional runs. By employing multiple steps, between-site reliability for 3T scanners was increased by 123%. Dropping one site at a time and assessing reliability can be a useful method of assessing the sensitivity of the results to particular sites. These findings should provide guidance toothers on the best practices for future multicenter studies.

  14. Re-test reliability of gustatory testing and introduction of the sensitive Taste-Drop-Test

    DEFF Research Database (Denmark)

    Fjaeldstad, A; Niklassen, A; Fernandes, H

    2018-01-01

    . Testing gustatory function can be important for diagnostics and assessment of treatment effects. However, the gustatory tests applied are required to be both sensitive and reliable.In this study, we investigate the re-test validity of popular Taste Strips gustatory test for gustatory screening....... Furthermore, we introduce a new sensitive Taste-Drop-Test, which was found to be superior for detecting a more accurate measure of tastant sensitivity....

  15. Reliability of the Test of Integrated Language and Literacy Skills (TILLS)

    Science.gov (United States)

    Mailend, Marja-Liisa; Plante, Elena; Anderson, Michele A.; Applegate, E. Brooks; Nelson, Nickola W.

    2016-01-01

    Background: As new standardized tests become commercially available, it is critical that clinicians have access to the information about a test's psychometric properties, including aspects of reliability. Aims: The purpose of the three studies reported in this article was to investigate the reliability of a new test, the Test of Integrated…

  16. Test-Retest Reliability of Computerized, Everyday Memory Measures and Traditional Memory Tests.

    Science.gov (United States)

    Youngjohn, James R.; And Others

    Test-retest reliabilities and practice effect magnitudes were considered for nine computer-simulated tasks of everyday cognition and five traditional neuropsychological tests. The nine simulated everyday memory tests were from the Memory Assessment Clinic battery as follows: (1) simple reaction time while driving; (2) divided attention (driving…

  17. Reliability testing of the Danish version of the Kidney Disease Quality of Life Short Form

    DEFF Research Database (Denmark)

    Molsted, Stig; Heaf, James; Prescott, Lotte

    2005-01-01

    . MATERIAL AND METHODS: Translation into Danish and back-translation into English were performed. Pilot, field and internal consistency reliability tests were performed. RESULTS: Cronbach's alpha coefficients for the internal reliability test ranged from 0.77 to 0.93 for the eight generic scales. In a test......OBJECTIVE: The questionnaire Kidney Disease Quality of Life Short Form version 1.3 (KDQOL-SF) is valuable for assessing the health-related quality of life in patients treated with chronic dialysis. The aim of this study was to translate and test the reliability of the KDQOL-SF for use in Denmark...... involving all patients, two of the disease-specific scales had Cronbach's alpha coefficients of test of the scores...

  18. Test-retest reliability of the multifocal photopic negative response.

    Science.gov (United States)

    Van Alstine, Anthony W; Viswanathan, Suresh

    2017-02-01

    To assess the test-retest reliability of the multifocal photopic negative response (mfPhNR) of normal human subjects. Multifocal electroretinograms were recorded from one eye of 61 healthy adult subjects on two separate days using a Visual Evoked Response Imaging System software version 4.3 (EDI, San Mateo, California). The visual stimulus delivered on a 75-Hz monitor consisted of seven equal-sized hexagons each subtending 12° of visual angle. The m-step exponent was 9, and the m-sequence was slowed to include at least 30 blank frames after each flash. Only the first slice of the first-order kernel was analyzed. The mfPhNR amplitude was measured at a fixed time in the trough from baseline (BT) as well as at the same fixed time in the trough from the preceding b-wave peak (PT). Additionally, we also analyzed BT normalized either to PT (BT/PT) or to the b-wave amplitude (BT/b-wave). The relative reliability of test-retest differences for each test location was estimated by the Wilcoxon matched-pair signed-rank test and intraclass correlation coefficients (ICC). Absolute test-retest reliability was estimated by Bland-Altman analysis. The test-retest amplitude differences for neither of the two measurement techniques were statistically significant as determined by Wilcoxon matched-pair signed-rank test. PT measurements showed greater ICC values than BT amplitude measurements for all test locations. For each measurement technique, the ICC value of the macular response was greater than that of the surrounding locations. The mean test-retest difference was close to zero for both techniques at each of the test locations, and while the coefficient of reliability (COR-1.96 times the standard deviation of the test-retest difference) was comparable for the two techniques at each test location when expressed in nanovolts, the %COR (COR normalized to the mean test and retest amplitudes) was superior for PT than BT measurements. The ICC and COR were comparable for the BT/PT and

  19. Technical report on the Piping Reliability Proving Tests at the Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    1993-05-01

    Japan Atomic Energy Research Institute (JAERI) conducts Piping Reliability Proving Tests from 1975 to 1992 based upon the contracts between JAERI and Science and Technology Agency of Japan (STA) under the auspices of the special account law for electric power development promotion. The purpose of these tests are to prove the structural reliability of the primary cooling piping constituting a part of the pressure boundary in the light water reactor power plants. The tests with large experimental facilities had ended already in 1990. Presently piping reliability analysis by the probabilistic fracture mechanics method is being done. Until now annual reports concerning the proving tests were produced and submitted to STA, whereas this report summarizes the test results done during these 16 years. Objectives of the piping reliability proving tests are to prove that the primary piping of the light water reactor (1) be reliable throughout the service period, (2) have no possibility of rupture, (3) bring no detrimental influence on the surrounding instrumentations or equipments near the break location even if it ruptured suddenly. To attain these objectives (i) pipe fatigue tests, (ii) unstable pipe fracture tests, (iii) pipe rupture tests and also the analyses by computer codes were done. After carrying out these tests, it is verified that the piping is reliable throughout the service period. The authors of this report are T. Isozaki, K. Shibata, S. Ueda, R. Kurihara, K. Onizawa and A. Kohsaka. The parts they wrote are shown in contents. (author)

  20. Are chiropractic tests for the lumbo-pelvic spine reliable and valid? A systematic critical literature review

    DEFF Research Database (Denmark)

    Hestbaek, L; Leboeuf-Yde, C

    2000-01-01

    OBJECTIVE: To systematically review the peer-reviewed literature about the reliability and validity of chiropractic tests used to determine the need for spinal manipulative therapy of the lumbo-pelvic spine, taking into account the quality of the studies. DATA SOURCES: The CHIROLARS database......-pelvic spine were included. DATA EXTRACTION: Data quality were assessed independently by the two reviewers, with a quality score based on predefined methodologic criteria. Results of the studies were then evaluated in relation to quality. DATA SYNTHESIS: None of the tests studied had been sufficiently...... evaluated in relation to reliability and validity. Only tests for palpation for pain had consistently acceptable results. Motion palpation of the lumbar spine might be valid but showed poor reliability, whereas motion palpation of the sacroiliac joints seemed to be slightly reliable but was not shown...

  1. Reliability of cognitive tests of ELSA-Brasil, the brazilian longitudinal study of adult health

    Science.gov (United States)

    Batista, Juliana Alves; Giatti, Luana; Barreto, Sandhi Maria; Galery, Ana Roscoe Papini; Passos, Valéria Maria de Azeredo

    2013-01-01

    Cognitive function evaluation entails the use of neuropsychological tests, applied exclusively or in sequence. The results of these tests may be influenced by factors related to the environment, the interviewer or the interviewee. OBJECTIVES We examined the test-retest reliability of some tests of the Brazilian version from the Consortium to Establish a Registry for Alzheimer's disease. METHODS The ELSA-Brasil is a multicentre study of civil servants (35-74 years of age) from public institutions across six Brazilian States. The same tests were applied, in different order of appearance, by the same trained and certified interviewer, with an approximate 20-day interval, to 160 adults (51% men, mean age 52 years). The Intraclass Correlation Coefficient (ICC) was used to assess the reliability of the measures; and a dispersion graph was used to examine the patterns of agreement between them. RESULTS We observed higher retest scores in all tests as well as a shorter test completion time for the Trail Making Test B. ICC values for each test were as following: Word List Learning Test (0.56), Word Recall (0.50), Word Recognition (0.35), Phonemic Verbal Fluency Test (VFT, 0.61), Semantic VFT (0.53) and Trail B (0.91). The Bland-Altman plot showed better correlation of executive function (VFT and Trail B) than of memory tests. CONCLUSIONS Better performance in retest may reflect a learning effect, and suggest that retest should be repeated using alternate forms or after longer periods. In this sample of adults with high schooling level, reliability was only moderate for memory tests whereas the measurement of executive function proved more reliable. PMID:29213860

  2. Reliability of Cognitive Tests of ELSA-Brasil, the Brazilian Longitudinal Study of Adult Health

    Directory of Open Access Journals (Sweden)

    Juliana Alves Batista

    Full Text Available ABSTRACT Cognitive function evaluation entails the use of neuropsychological tests, applied exclusively or in sequence. The results of these tests may be influenced by factors related to the environment, the interviewer or the interviewee. Objectives: We examined the test-retest reliability of some tests of the Brazilian version from the Consortium to Establish a Registry for Alzheimer's disease. Methods: The ELSA-Brasil is a multicentre study of civil servants (35-74 years of age from public institutions across six Brazilian States. The same tests were applied, in different order of appearance, by the same trained and certified interviewer, with an approximate 20-day interval, to 160 adults (51% men, mean age 52 years. The Intraclass Correlation Coefficient (ICC was used to assess the reliability of the measures; and a dispersion graph was used to examine the patterns of agreement between them. Results: We observed higher retest scores in all tests as well as a shorter test completion time for the Trail Making Test B. ICC values for each test were as following: Word List Learning Test (0.56, Word Recall (0.50, Word Recognition (0.35, Phonemic Verbal Fluency Test (VFT, 0.61, Semantic VFT (0.53 and Trail B (0.91. The Bland-Altman plot showed better correlation of executive function (VFT and Trail B than of memory tests. Conclusions: Better performance in retest may reflect a learning effect, and suggest that retest should be repeated using alternate forms or after longer periods. In this sample of adults with high schooling level, reliability was only moderate for memory tests whereas the measurement of executive function proved more reliable.

  3. Reliability testing of failed fuel location system

    International Nuclear Information System (INIS)

    Vieru, G.

    1996-01-01

    This paper presents the experimental reliability tests performed in order to prove the reliability parameters for Failed Fuel Location System (FFLS), equipment used to detect in which channel of a particular heat transport loop a fuel failure is located, and to find in which channel what particular bundle pair is failed. To do so, D20 samples from each reactor channel are sequentially monitored to detect a comparatively high level of delayed neutron activity. 15 refs, 8 figs, 2 tabs

  4. Reliability of nondestructive testing of metal strength properties for power equipment

    International Nuclear Information System (INIS)

    Bugaj, N.V.; Lebedev, A.A.; Sharko, A.V.

    1985-01-01

    Ultrasonic control which is a constituent part of a complex control system which includes specimen-free (by hardness) tests, random breaking tests and acoustic measurements is stUdied for its reliability with respect to strength properties of power-equipment metal. Quantitative and alternative criteria are developed to estimate quality of elements for power-equipment according to results of metal strength properties. Acoustic control results are presented for ultimate strength in 12Kh1MF-steel

  5. Impact of relationships between test and training animals and among training animals on reliability of genomic prediction.

    Science.gov (United States)

    Wu, X; Lund, M S; Sun, D; Zhang, Q; Su, G

    2015-10-01

    One of the factors affecting the reliability of genomic prediction is the relationship among the animals of interest. This study investigated the reliability of genomic prediction in various scenarios with regard to the relationship between test and training animals, and among animals within the training data set. Different training data sets were generated from EuroGenomics data and a group of Nordic Holstein bulls (born in 2005 and afterwards) as a common test data set. Genomic breeding values were predicted using a genomic best linear unbiased prediction model and a Bayesian mixture model. The results showed that a closer relationship between test and training animals led to a higher reliability of genomic predictions for the test animals, while a closer relationship among training animals resulted in a lower reliability. In addition, the Bayesian mixture model in general led to a slightly higher reliability of genomic prediction, especially for the scenario of distant relationships between training and test animals. Therefore, to prevent a decrease in reliability, constant updates of the training population with animals from more recent generations are required. Moreover, a training population consisting of less-related animals is favourable for reliability of genomic prediction. © 2015 Blackwell Verlag GmbH.

  6. Validity, Reliability, and Sensitivity of a Volleyball Intermittent Endurance Test.

    Science.gov (United States)

    Rodríguez-Marroyo, Jose A; Medina-Carrillo, Javier; García-López, Juan; Morante, Juan C; Villa, José G; Foster, Carl

    2017-03-01

    To analyze the concurrent and construct validity of a volleyball intermittent endurance test (VIET). The VIET's test-retest reliability and sensitivity to assess seasonal changes was also studied. During the preseason, 71 volleyball players of different competitive levels took part in this study. All performed the VIET and a graded treadmill test with gas-exchange measurement (GXT). Thirty-one of the players performed an additional VIET to analyze the test-retest reliability. To test the VIET's sensitivity, 28 players repeated the VIET and GXT at the end of their season. Significant (P volleyball players.

  7. Design of Accelerated Reliability Test for CNC Motorized Spindle Based on Vibration Signal

    Directory of Open Access Journals (Sweden)

    Chen Chao

    2016-01-01

    Full Text Available Motorized spindle is the key functional component of CNC machining centers which is a mechatronics system with long life and high reliability. The reliability test cycle of motorized spindle is too long and infeasible. This paper proposes a new accelerated test for reliability evaluation of motorized spindle. By field reliability test, authors collect and calculate the load data including rotational speed, cutting force and torque. Load spectrum distribution law is analyzed. And authors design a test platform to apply the load spectrum. A new method to define the fuzzy acceleration factor based on the vibration signal is proposed. Then the whole test plan of accelerated reliability test is done.

  8. Digital System Reliability Test for the Evaluation of safety Critical Software of Digital Reactor Protection System

    Directory of Open Access Journals (Sweden)

    Hyun-Kook Shin

    2006-08-01

    Full Text Available A new Digital Reactor Protection System (DRPS based on VME bus Single Board Computer has been developed by KOPEC to prevent software Common Mode Failure(CMF inside digital system. The new DRPS has been proved to be an effective digital safety system to prevent CMF by Defense-in-Depth and Diversity (DID&D analysis. However, for practical use in Nuclear Power Plants, the performance test and the reliability test are essential for the digital system qualification. In this study, a single channel of DRPS prototype has been manufactured for the evaluation of DRPS capabilities. The integrated functional tests are performed and the system reliability is analyzed and tested. The results of reliability test show that the application software of DRPS has a very high reliability compared with the analog reactor protection systems.

  9. Improving QST Reliability – More Raters, Tests or Occasions? A Multivariate Generalizability Study

    DEFF Research Database (Denmark)

    O'Neill, Søren; O'Neill, Lotte

    2015-01-01

    The reliability of quantitative sensory testing (QST) is affected by the error attributable to both test occasion and rater (examiner) as well as interactions between them. Most reliability studies only account for one source of error. The present study employed a fully-crossed, multivariate...... threshold, intensity, tolerance and modulation with mechanical, thermal and chemical stimuli. The classical test-retest and inter-rater reliability (0.19... procedures. Reliability was improved more by repeated testing on separate occasions opposed to repeated testing by different raters....

  10. Reliability test and failure analysis of high power LED packages

    International Nuclear Information System (INIS)

    Chen Zhaohui; Zhang Qin; Wang Kai; Luo Xiaobing; Liu Sheng

    2011-01-01

    A new type application specific light emitting diode (LED) package (ASLP) with freeform polycarbonate lens for street lighting is developed, whose manufacturing processes are compatible with a typical LED packaging process. The reliability test methods and failure criterions from different vendors are reviewed and compared. It is found that test methods and failure criterions are quite different. The rapid reliability assessment standards are urgently needed for the LED industry. 85 0 C/85 RH with 700 mA is used to test our LED modules with three other vendors for 1000 h, showing no visible degradation in optical performance for our modules, with two other vendors showing significant degradation. Some failure analysis methods such as C-SAM, Nano X-ray CT and optical microscope are used for LED packages. Some failure mechanisms such as delaminations and cracks are detected in the LED packages after the accelerated reliability testing. The finite element simulation method is helpful for the failure analysis and design of the reliability of the LED packaging. One example is used to show one currently used module in industry is vulnerable and may not easily pass the harsh thermal cycle testing. (semiconductor devices)

  11. Test-retest reliability of the driving habits questionnaire in older self-driving adults.

    Science.gov (United States)

    Song, Chiang-Soon; Chun, Byung-Yoon; Chung, Hyun-Sook

    2015-11-01

    [Purpose] The purpose of this study was to investigate the test-retest reliability of the Driving Habits Questionnaire in community-dwelling older self-drivers. [Subjects and Methods] Seventy-four participants were recruited by convenience sampling from local rehabilitation centers. This was a cross-sectional study design that used two clinical measures: the Driving Habits Questionnaire and Mini-mental State Examination. To examine the test-retest reliability of the Driving Habits Questionnaire, the clinical tool was measured twice, five days apart. [Results] The Driving Habits Questionnaire showed good reliability for older community-dwelling self-drivers. The Cronbach's alpha coefficients for the four domains of dependence (0.572), difficulty (0.871), crashes and citations (0.689), and driving space (0.961) of the Driving Habits Questionnaire indicated good or high internal consistency. Driving difficulty correlated significantly with self-reported crashes and citations and driving space. [Conclusion] The results of this study suggest that the Driving Habits Questionnaire is a reliable measure of self-reported interview-based driving behavior in the community-dwelling elderly.

  12. Validity and Reliability of a Medicine Ball Explosive Power Test.

    Science.gov (United States)

    Stockbrugger, Barry A.; Haennel, Robert G.

    2001-01-01

    Evaluated the validity and reliability of a medicine ball throw test to evaluate explosive power. Data on competitive sand volleyball players who performed a medicine ball throw and a standard countermovement jump indicated that the medicine ball throw test was a valid and reliable way to assess explosive power for an analogous total-body movement…

  13. Reliability and smallest real difference of the ankle lunge test post ankle fracture.

    Science.gov (United States)

    Simondson, David; Brock, Kim; Cotton, Susan

    2012-02-01

    This study aimed to determine the reliability and the smallest real difference of the Ankle Lunge test in an ankle fracture patient population. In the post immobilisation stage of ankle fracture, ankle dorsiflexion is an important measure of progress and outcome. The Ankle Lunge test measures weight bearing dorsiflexion, resulting in negative scores (knee to wall distance) and positive scores (toe to wall distance), for which the latter has proven reliability in normal subjects only. A consecutive sample of ankle fracture patients with permission to commence weight bearing, were recruited to the study. Three measurements of the Ankle Lunge Test were performed each by two raters, one senior and one junior physiotherapist. These occurred prior to therapy sessions in the second week after plaster removal. A standardised testing station was utilised and allowed for both knee to wall distance and toe to wall distance measurement. Data was collected from 10 individuals with ankle fracture, with an average age of 36 years (SD 14.8). Seventy seven percent of observations were negative. Intra and inter-rater reliability yielded intra class correlations at or above 0.97, p Ankle Lunge test is a practical and reliable tool for measuring weightbearing dorsiflexion post ankle fracture. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. An Integrated Approach to Establish Validity and Reliability of Reading Tests

    Science.gov (United States)

    Razi, Salim

    2012-01-01

    This study presents the processes of developing and establishing reliability and validity of a reading test by administering an integrative approach as conventional reliability and validity measures superficially reveals the difficulty of a reading test. In this respect, analysing vocabulary frequency of the test is regarded as a more eligible way…

  15. Reliability analysis applied to structural tests

    Science.gov (United States)

    Diamond, P.; Payne, A. O.

    1972-01-01

    The application of reliability theory to predict, from structural fatigue test data, the risk of failure of a structure under service conditions because its load-carrying capability is progressively reduced by the extension of a fatigue crack, is considered. The procedure is applicable to both safe-life and fail-safe structures and, for a prescribed safety level, it will enable an inspection procedure to be planned or, if inspection is not feasible, it will evaluate the life to replacement. The theory has been further developed to cope with the case of structures with initial cracks, such as can occur in modern high-strength materials which are susceptible to the formation of small flaws during the production process. The method has been applied to a structure of high-strength steel and the results are compared with those obtained by the current life estimation procedures. This has shown that the conventional methods can be unconservative in certain cases, depending on the characteristics of the structure and the design operating conditions. The suitability of the probabilistic approach to the interpretation of the results from full-scale fatigue testing of aircraft structures is discussed and the assumptions involved are examined.

  16. The test-retest reliability and criterion validity of a high-intensity, netball-specific circuit test: The Net-Test.

    Science.gov (United States)

    Mungovan, Sean F; Peralta, Paula J; Gass, Gregory C; Scanlan, Aaron T

    2018-04-12

    To examine the test-retest reliability and criterion validity of a high-intensity, netball-specific fitness test. Repeated measures, within-subject design. Eighteen female netball players competing in an international competition completed a trial of the Net-Test, which consists of 14 timed netball-specific movements. Players also completed a series of netball-relevant criterion fitness tests. Ten players completed an additional Net-Test trial one week later to assess test-retest reliability using intraclass correlation coefficient (ICC), typical error of measurement (TEM), and coefficient of variation (CV). The typical error of estimate expressed as CV and Pearson correlations were calculated between each criterion test and Net-Test performance to assess criterion validity. Five movements during the Net-Test displayed moderate ICC (0.84-0.90) and two movements displayed high ICC (0.91-0.93). Seven movements and heart rate taken during the Net-Test held low CV (Test possessed low CV and significant (pTest possesses acceptable reliability for the assessment of netball fitness. Further, the high criterion validity for the Net-Test suggests a range of important netball-specific fitness elements are assessed in combination. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  17. Test-Retest Reliability of Diffusion Tensor Imaging in Huntington's Disease.

    Science.gov (United States)

    Cole, James H; Farmer, Ruth E; Rees, Elin M; Johnson, Hans J; Frost, Chris; Scahill, Rachael I; Hobbs, Nicola Z

    2014-03-21

    Diffusion tensor imaging (DTI) has shown microstructural abnormalities in patients with Huntington's Disease (HD) and work is underway to characterise how these abnormalities change with disease progression. Using methods that will be applied in longitudinal research, we sought to establish the reliability of DTI in early HD patients and controls. Test-retest reliability, quantified using the intraclass correlation coefficient (ICC), was assessed using region-of-interest (ROI)-based white matter atlas and voxelwise approaches on repeat scan data from 22 participants (10 early HD, 12 controls). T1 data was used to generate further ROIs for analysis in a reduced sample of 18 participants. The results suggest that fractional anisotropy (FA) and other diffusivity metrics are generally highly reliable, with ICCs indicating considerably lower within-subject compared to between-subject variability in both HD patients and controls. Where ICC was low, particularly for the diffusivity measures in the caudate and putamen, this was partly influenced by outliers. The analysis suggests that the specific DTI methods used here are appropriate for cross-sectional research in HD, and give confidence that they can also be applied longitudinally, although this requires further investigation. An important caveat for DTI studies is that test-retest reliability may not be evenly distributed throughout the brain whereby highly anisotropic white matter regions tended to show lower relative within-subject variability than other white or grey matter regions.

  18. Educational testing validity and reliability in pharmacy and medical education literature.

    Science.gov (United States)

    Hoover, Matthew J; Jung, Rose; Jacobs, David M; Peeters, Michael J

    2013-12-16

    To evaluate and compare the reliability and validity of educational testing reported in pharmacy education journals to medical education literature. Descriptions of validity evidence sources (content, construct, criterion, and reliability) were extracted from articles that reported educational testing of learners' knowledge, skills, and/or abilities. Using educational testing, the findings of 108 pharmacy education articles were compared to the findings of 198 medical education articles. For pharmacy educational testing, 14 articles (13%) reported more than 1 validity evidence source while 83 articles (77%) reported 1 validity evidence source and 11 articles (10%) did not have evidence. Among validity evidence sources, content validity was reported most frequently. Compared with pharmacy education literature, more medical education articles reported both validity and reliability (59%; particles in pharmacy education compared to medical education, validity, and reliability reporting were limited in the pharmacy education literature.

  19. Reliability of physical examination tests for the diagnosis of knee disorders: Evidence from a systematic review.

    Science.gov (United States)

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Desmeules, François

    2016-12-01

    Clinicians often rely on physical examination tests to guide them in the diagnostic process of knee disorders. However, reliability of these tests is often overlooked and may influence the consistency of results and overall diagnostic validity. Therefore, the objective of this study was to systematically review evidence on the reliability of physical examination tests for the diagnosis of knee disorders. A structured literature search was conducted in databases up to January 2016. Included studies needed to report reliability measures of at least one physical test for any knee disorder. Methodological quality was evaluated using the QAREL checklist. A qualitative synthesis of the evidence was performed. Thirty-three studies were included with a mean QAREL score of 5.5 ± 0.5. Based on low to moderate quality evidence, the Thessaly test for meniscal injuries reached moderate inter-rater reliability (k = 0.54). Based on moderate to excellent quality evidence, the Lachman for anterior cruciate ligament injuries reached moderate to excellent inter-rater reliability (k = 0.42 to 0.81). Based on low to moderate quality evidence, the Tibiofemoral Crepitus, Joint Line and Patellofemoral Pain/Tenderness, Bony Enlargement and Joint Pain on Movement tests for knee osteoarthritis reached fair to excellent inter-rater reliability (k = 0.29 to 0.93). Based on low to moderate quality evidence, the Lateral Glide, Lateral Tilt, Lateral Pull and Quality of Movement tests for patellofemoral pain reached moderate to good inter-rater reliability (k = 0.49 to 0.73). Many physical tests appear to reach good inter-rater reliability, but this is based on low-quality and conflicting evidence. High-quality research is required to evaluate the reliability of knee physical examination tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. IRT-Estimated Reliability for Tests Containing Mixed Item Formats

    Science.gov (United States)

    Shu, Lianghua; Schwarz, Richard D.

    2014-01-01

    As a global measure of precision, item response theory (IRT) estimated reliability is derived for four coefficients (Cronbach's a, Feldt-Raju, stratified a, and marginal reliability). Models with different underlying assumptions concerning test-part similarity are discussed. A detailed computational example is presented for the targeted…

  1. Evaluating the reliability of an injury prevention screening tool: Test-retest study.

    Science.gov (United States)

    Gittelman, Michael A; Kincaid, Madeline; Denny, Sarah; Wervey Arnold, Melissa; FitzGerald, Michael; Carle, Adam C; Mara, Constance A

    2016-10-01

    A standardized injury prevention (IP) screening tool can identify family risks and allow pediatricians to address behaviors. To assess behavior changes on later screens, the tool must be reliable for an individual and ideally between household members. Little research has examined the reliability of safety screening tool questions. This study utilized test-retest reliability of parent responses on an existing IP questionnaire and also compared responses between household parents. Investigators recruited parents of children 0 to 1 year of age during admission to a tertiary care children's hospital. When both parents were present, one was chosen as the "primary" respondent. Primary respondents completed the 30-question IP screening tool after consent, and they were re-screened approximately 4 hours later to test individual reliability. The "second" parent, when present, only completed the tool once. All participants received a 10-dollar gift card. Cohen's Kappa was used to estimate test-retest reliability and inter-rater agreement. Standard test-retest criteria consider Kappa values: 0.0 to 0.40 poor to fair, 0.41 to 0.60 moderate, 0.61 to 0.80 substantial, and 0.81 to 1.00 as almost perfect reliability. One hundred five families participated, with five lost to follow-up. Thirty-two (30.5%) parent dyads completed the tool. Primary respondents were generally mothers (88%) and Caucasian (72%). Test-retest of the primary respondents showed their responses to be almost perfect; average 0.82 (SD = 0.13, range 0.49-1.00). Seventeen questions had almost perfect test-retest reliability and 11 had substantial reliability. However, inter-rater agreement between household members for 12 objective questions showed little agreement between responses; inter-rater agreement averaged 0.35 (SD = 0.34, range -0.19-1.00). One question had almost perfect inter-rater agreement and two had substantial inter-rater agreement. The IP screening tool used by a single individual had excellent

  2. Balance Assessment in Sports-Related Concussion: Evaluating Test-Retest Reliability of the Equilibrate System.

    Science.gov (United States)

    Odom, Mitchell J; Lee, Young M; Zuckerman, Scott L; Apple, Rachel P; Germanos, Theodore; Solomon, Gary S; Sills, Allen K

    2016-01-01

    This study evaluated the test-retest reliability of a novel computer-based, portable balance assessment tool, the Equilibrate System (ES), used to diagnose sports-related concussion. Twenty-seven students participated in ES testing consisting of three sessions over 4 weeks. The modified Balance Error Scoring System was performed. For each participant, test-retest reliability was established using the intraclass correlation coefficient (ICC). The ES test-retest reliability from baseline to week 2 produced an ICC value of 0.495 (95% CI, 0.123-0.745). Week 2 testing produced ICC values of 0.602 (95% CI, 0.279-0.803) and 0.610 (95% CI, 0.299-0.804), respectively. All other single measures test-retest reliability values produced poor ICC values. Same-day ES testing showed fair to good test-retest reliability while interweek measures displayed poor to fair test-retest reliability. Testing conditions should be controlled when using computerized balance assessment methods. ES testing should only be used as a part of a comprehensive assessment.

  3. Validity and Reliability of the Clock Drawing Test in Older People

    Directory of Open Access Journals (Sweden)

    Massoumeh Sadeghipour Roodsari

    2013-07-01

    Full Text Available Objectives: Early diagnosis of cognitive disorders in order to initiate new efficient treatments in time is an important task which cannot be fulfilled without proper cognitive screening tools. The Clock Drawing Test (CDT is a simple inexpensive cognitive screening tool which can be used in primary care settings delivering health services to older people. The aim of this study was to assess validity and reliability of the CDT in Iranian older population. Methods & Materials: In this study the CDT and Mini Mental State Examination (MMSE were concurrently performed on 74 literate participants aged 60 and over. Participants were recruited from the clients of Iran Alzheimer’s Association (dementia patients and non-demented clients, including other patients or care givers during a 5 month period. The CDT was performed by two trained raters using Shulman’s six points scoring method. Using SPSS version 20, reliability was assessed measuring kappa statistics as well as ICC. Concurrent validity between CDT and MMSE were statistically analyzed by spearman’s rank correlation coefficient. Results: Mean age of the participants was 72 years in a range of 60 to 90 years with equal numbers 0f male and female participants. Kappa statistics for test retest reliability was 0.554 (P<0.001. ICC for inter rater reliability was 0.964 (P<0.001. Spearman’s rank correlation coefficient for MMSE and CDT scores was 0.782, statistically significant at P<0.001. Conclusion: CDT is a valid and reliable test in literate older people that can be used as a cognitive screening tool in Iranian older population.

  4. Reliability, Validity and Factor Structure of Drug Abuse Screening Test

    Directory of Open Access Journals (Sweden)

    Sayed Hadi Sayed Alitabar

    2016-05-01

    Full Text Available Background and Objective: According to the increasing of substance use in the country, more researches about this phenomenon are necessary. This Study Investigates the Validity, Reliability and Confirmatory Factor Structure of the Drug Abuse Screening test (DAST. Materials and Methods: The Sample Consisted of 381 Patients (143 Women and 238 Men with a Multi-Stage Cluster Sampling of Areas 2, 6 and 12 of Tehran Were Selected from Each Region, 6 Randomly Selected Drug Rehabilitation Center. The DAST Was Used as Instrument. Divergent & Convergent Validity of this Scale Was Assessed with Problems Assessment for Substance Using Psychiatric Patients (PASUPP and Relapse Prediction Scale (RPS.Results: The DAST after the First Time Factor Structure of Using Confirmatory Factor Analysis Was Confirmed. The DAST Had a Good Internal Consistency (Cranach’s Alpha, and the Reliability of the Test Within a Week, 0.9, 0.8. Also this Scale Had a Positive Correlation with Problems Assessment for Substance Using Psychiatric Patients and Relapse Prediction Scale (P<0.01.Conclusion: The Overall Results Showed that the Drug Abuse Screening Test in Iranian Society Is Valid. It Can Be Said that Self-Report Scale Tool Is Useful for Research Purposes and Addiction.

  5. Reliability of the "Ten Test" for assessment of discriminative sensation in hand trauma.

    Science.gov (United States)

    Berger, Michael J; Regan, William R; Seal, Alex; Bristol, Sean G

    2016-10-01

    "Ten Test" (TT) is a bedside measure of discriminative sensation, whereby the magnitude of abnormal sensation to moving light touch is normalized to an area of normal sensation on an 11-point Likert scale (0-10). The purposes of this study were to determine reliability parameters of the TT in a cohort of patients presenting to a hand trauma clinic with subjectively altered sensation post-injury and to compare the reliability of TT to that of the Weinstein Enhanced Sensory Test (WEST). Study participants (n = 29, mean age = 37 ± 12) comprised patients presenting to an outpatient hand trauma clinic with recent hand trauma and self reported abnormal sensation. Participants underwent TT and WEST by two separate raters on the same day. Interrater reliability, response stability and responsiveness of each test were determined by the intraclass correlation coefficient (ICC: 2, 1), standard error of measurement (SEM) with 95% confidence intervals (CI) and minimal detectable difference score, with 95% CI (MDD95), respectively. The TT displayed excellent interrater reliability (ICC = 0.95, 95% CI 0.89-0.97) compared to good reliability for WEST (ICC = 0.78, 95% CI 0.58-0.89). The range of true scores expected with 95% confidence based on the SEM (i.e. response stability), was ±1.1 for TT and ±1.1 for WEST. MDD95 scores reflecting test responsiveness were 1.5 and 1.6 for TT and WEST, respectively. The TT displayed excellent reliability parameters in this patient population. Reliability parameters were stronger for TT compared to WEST. These results provide support for the use of TT as a component of the sensory exam in hand trauma. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Reliability of externally fixed dynamometry hamstring strength testing in elite youth football players.

    Science.gov (United States)

    Wollin, Martin; Purdam, Craig; Drew, Michael K

    2016-01-01

    To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  7. Intersession reliability of self-selected and narrow stance balance testing in older adults.

    Science.gov (United States)

    Riemann, Bryan L; Piersol, Kelsey

    2017-10-01

    Despite the common practice of using force platforms to assess balance of older adults, few investigations have examined the reliability of postural screening tests in this population. We sought to determine the test-retest reliability of self-selected and narrow stance balance testing with eyes open and eyes closed in healthy older adults. Thirty older adults (>65 years) completed 45 s trials of eyes open and eyes closed stability tests using self-selected and narrow stances on two separate days (1.9 ± .7 days). Average medial-lateral center of pressure velocity was computed. The ICC results ranged from .74 to .86, and no significant systematic changes (P eyes open and closed balance testing using self-selected and narrow stances in older adults was established which should provide a foundation for the development of fall risk screening tests.

  8. Reliability demonstration methodology for products with Gamma Process by optimal accelerated degradation testing

    International Nuclear Information System (INIS)

    Zhang, Chunhua; Lu, Xiang; Tan, Yuanyuan; Wang, Yashun

    2015-01-01

    For products with high reliability and long lifetime, accelerated degradation testing (ADT) may be adopted during product development phase to verify whether its reliability satisfies the predetermined level within feasible test duration. The actual degradation from engineering is usually a strictly monotonic process, such as fatigue crack growth, wear, and erosion. However, the method for reliability demonstration by ADT with monotonic degradation process has not been investigated so far. This paper proposes a reliability demonstration methodology by ADT for this kind of product. We first apply Gamma process to describe the monotonic degradation. Next, we present a reliability demonstration method by converting the required reliability level into allowable cumulative degradation in ADT and comparing the actual accumulative degradation with the allowable level. Further, we suggest an analytical optimal ADT design method for more efficient reliability demonstration by minimizing the asymptotic variance of decision variable in reliability demonstration under the constraints of sample size, test duration, test cost, and predetermined decision risks. The method is validated and illustrated with example on reliability demonstration of alloy product, and is applied to demonstrate the wear reliability within long service duration of spherical plain bearing in the end. - Highlights: • We present a reliability demonstration method by ADT for products with monotonic degradation process, which may be applied to verify reliability with long service life for products with monotonic degradation process within feasible test duration. • We suggest an analytical optimal ADT design method for more efficient reliability demonstration, which differs from the existed optimal ADT design for more accurate reliability estimation by different objective function and different constraints. • The methods are applied to demonstrate the wear reliability within long service duration of

  9. A Latent Class Approach to Estimating Test-Score Reliability

    Science.gov (United States)

    van der Ark, L. Andries; van der Palm, Daniel W.; Sijtsma, Klaas

    2011-01-01

    This study presents a general framework for single-administration reliability methods, such as Cronbach's alpha, Guttman's lambda-2, and method MS. This general framework was used to derive a new approach to estimating test-score reliability by means of the unrestricted latent class model. This new approach is the latent class reliability…

  10. Development of a valid and reliable test to assess trauma radiograph interpretation performance

    International Nuclear Information System (INIS)

    Neep, M.J.; Steffens, T.; Riley, V.; Eastgate, P.; McPhail, S.M.

    2017-01-01

    Objectives: The purpose of this investigation was to develop and examine the preliminary validity and reliability among radiographers of a test to assess trauma radiograph interpretation performance suitable for use among health professionals. Methods: Stage 1 examined 14,159 consecutive appendicular and axial examinations from a hospital emergency department over a 12 month period to quantify a typical anatomical region case-mix of trauma radiographs. A sample of radiographic cases representative of affected anatomical regions was then developed into the Image Interpretation Test (IIT). Stage 2 involved prospective investigations of the IIT's reliability (inter-rater, intra-rater, internal consistency) and validity (concurrent) among 41 radiographers. Results: The IIT included 60 cases. The median (interquartile range) clinical experience of participants was 5 (2–10) years. Case scores were internally consistent (Cronbach's alpha = 0.90). Favourable inter-rater reliability (kappa > 0.70 for 58/60 cases, Intra-class correlation coefficient (ICC) > 0.99 for total score) and intra-rater reliability (kappa > 0.90 for 60/60 cases, ICC > 0.99 for total score) was observed. There was a positive association between radiographers' confidence in image interpretation and IIT score (coefficient = 1.52, r-squared = 0.60, p < 0.001). Conclusions: The IIT developed during this investigation included a selection of radiographic cases consistent with anatomical regions represented in an adult trauma case-mix. This study has also provided foundational preliminary evidence to support the reliability and validity of the IIT among radiographers. The findings suggest that it is possible to assess image interpretation performance of adult trauma radiographs with this test. - Highlights: • Development of an Image Interpretation Test (IIT). • Cases consistent with anatomical regions represented in a typical adult trauma case-mix. • Development of a

  11. Identification of conductive hearing loss using air conduction tests alone: reliability and validity of an automatic test battery.

    Science.gov (United States)

    Convery, Elizabeth; Keidser, Gitte; Seeto, Mark; Freeston, Katrina; Zhou, Dan; Dillon, Harvey

    2014-01-01

    The primary objective of this study was to determine whether a combination of automatically administered pure-tone audiometry and a tone-in-noise detection task, both delivered via an air conduction (AC) pathway, could reliably and validly predict the presence of a conductive component to the hearing loss. The authors hypothesized that performance on the battery of tests would vary according to hearing loss type. A secondary objective was to evaluate the reliability and validity of a novel automatic audiometry algorithm to assess its suitability for inclusion in the test battery. Participants underwent a series of hearing assessments that were conducted in a randomized order: manual pure-tone air conduction audiometry and bone conduction audiometry; automatic pure-tone air conduction audiometry; and an automatic tone-in-noise detection task. The automatic tests were each administered twice. The ability of the automatic test battery to: (a) predict the presence of an air-bone gap (ABG); and (b) accurately measure AC hearing thresholds was assessed against the results of manual audiometry. Test-retest conditions were compared to determine the reliability of each component of the automatic test battery. Data were collected on 120 ears from normal-hearing and conductive, sensorineural, and mixed hearing-loss subgroups. Performance differences between different types of hearing loss were observed. Ears with a conductive component (conductive and mixed ears) tended to have normal signal to noise ratios (SNR) despite impaired thresholds in quiet, while ears without a conductive component (normal and sensorineural ears) demonstrated, on average, an increasing relationship between their thresholds in quiet and their achieved SNR. Using the relationship between these two measures among ears with no conductive component as a benchmark, the likelihood that an ear has a conductive component can be estimated based on the deviation from this benchmark. The sensitivity and

  12. Validity and reliability of tests determining performance-related components of wheelchair basketball

    NARCIS (Netherlands)

    De Groot, Sonja; Balvers, Inge J. M.; Kouwenhoven, Sanne M.; Janssen, Thomas W. J.

    2012-01-01

    The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players'

  13. Validity and reliability of tests determining performance-related components of wheelchair basketball

    NARCIS (Netherlands)

    de Groot, Sonja; Balvers, Inge J.M.; Kouwenhoven, Sanne M.; Janssen, Thomas W.J.

    The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players'

  14. Strength and Pain Threshold Handheld Dynamometry Test Reliability in Patellofemoral Pain.

    Science.gov (United States)

    van der Heijden, R A; Vollebregt, T; Bierma-Zeinstra, S M A; van Middelkoop, M

    2015-12-01

    Patellofemoral pain syndrome (PFPS), characterized by peri- and retropatellar pain, is a common disorder in young, active people. The etiology is unclear; however, quadriceps strength seems to be a contributing factor, and sensitization might play a role. The study purpose is determining the inter-rater reliability of handheld dynamometry to test both quadriceps strength and pressure pain threshold (PPT), a measure for sensitization, in patients with PFPS. This cross-sectional case-control study comprises 3 quadriceps strength and one PPT measurements performed by 2 independent investigators in 22 PFPS patients and 16 matched controls. Inter-rater reliability was analyzed using intraclass correlation coefficients (ICC) and Bland-Altman plots. Inter-rater reliability of quadriceps strength testing was fair to good in PFPS patients (ICC=0.72) and controls (ICC=0.63). Bland-Altman plots showed an increased difference between assessors when average quadriceps strength values exceeded 250 N. Inter-rater reliability of PPT was excellent in patients (ICC=0.79) and fair to good in controls (ICC=0.52). Handheld dynamometry seems to be a reliable method to test both quadriceps strength and PPT in PFPS patients. Inter-rater reliability was higher in PFPS patients compared to control subjects. With regard to quadriceps testing, a higher variance between assessors occurs when quadriceps strength increases. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Enhance pump reliability through improved inservice testing

    International Nuclear Information System (INIS)

    Healy, J.J.

    1990-01-01

    EPRI has undertaken a study to assess the effectiveness of existing testing programs to accurately monitor and predict performance changes before either pump performance degrades or an actual failure occurs. Anticipated changes in inservice testing techniques are directed towards enhancing the validity of test data, ensuring its repeatability, and avoiding deterioration of the pump assembly. There is a new-found interest in test programs of all types that has occurred, in part, because of an increase in reported pump degradation and pump failure. Inservice testing of pumps, which has long been a basis for assuring operability, has apparently produced an opposite effect; namely, the appearance of a reduction in reliability

  16. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Science.gov (United States)

    Guimarães, M. C.; Silva, C. R. E.; Rosado, P. H. G.; Cunha, P. G.; Da Silva, T. A.

    2018-03-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work.

  17. Test-retest reliability of the Military Pre-training Questionnaire.

    Science.gov (United States)

    Robinson, M; Stokes, K; Bilzon, J; Standage, M; Brown, P; Thompson, D

    2010-09-01

    Musculoskeletal injuries are a significant cause of morbidity during military training. A brief, inexpensive and user-friendly tool that demonstrates reliability and validity is warranted to effectively monitor the relationship between multiple predictor variables and injury incidence in military populations. To examine the test-retest reliability of the Military Pre-training Questionnaire (MPQ), designed specifically to assess risk factors for injury among military trainees across five domains (physical activity, injury history, diet, alcohol and smoking). Analyses were based on a convenience sample of 58 male British Army trainees. Kappa (kappa), weighted kappa (kappa(w)) and intraclass correlation coefficients (ICC) were used to evaluate the 2-week test-retest reliability of the MPQ. For index measures constituting the assessment of a given construct, internal consistency was assessed by Cronbach's alpha (alpha) coefficients. Reliability of individual items ranged from poor to almost perfect (kappa range = 0.45-0.86; kappa(w) range = 0.11-0.91; ICC range = 0.34-0.86) with most items demonstrating moderate reliability. Overall scores related to physical activity, diet, alcohol and smoking constructs were reliable between both administrations (ICC = 0.63-0.85). Support for the internal consistency of the incorporated alcohol (alpha = 0.78) and cigarette (alpha = 0.75) scales was also provided. The MPQ is a reliable self-report instrument for assessing multiple injury-related risk factors during initial military training. Further assessment of the psychometric properties of the MPQ (e.g. different types of validity) with military populations/samples will support its interpretation and use in future surveillance and epidemiological studies.

  18. Reliability and accuracy of Cooper's test in male long distance runners

    OpenAIRE

    J.R. Alvero-Cruz; M.A. Giráldez García; E.A. Carnero

    2017-01-01

    Objective: Endurance capacity can be assessed by field test such as Cooper's test; however, reliability and accuracy are rarely reported in the literature. It was our aims to describe reliability and accuracy of Cooper's test in long distance runners. Method: Fifteen male long distance runners performed twice all-out Cooper's test in a 400 m track. Total distance covered, maximum heart rate (HR) and rate of perceived exertion were recorded. Bias correction factor (Bc) was used to describe ...

  19. The Reliability of a Functional Agility Test for Water Polo

    Directory of Open Access Journals (Sweden)

    Tucher Guilherme

    2014-07-01

    Full Text Available Few functional agility tests for water polo take into consideration its specific characteristics. The preliminary objective of this study was to evaluate the reliability of an agility test for water polo players. Fifteen players (16.3 ± 1.8 years old with a minimum of two years of competitive experience were evaluated. A Functional Test for Agility Performance (FTAP was designed to represent the context of this sport. Several trials were performed to familiarize the athlete with the movement. Two experienced coaches measured three repetitions of the FTAP. Descriptive statistics, repeated measures analysis of variance (ANOVA, 95% limit of agreement (LOA, intraclass correlation coefficient (ICC and standard error of measurements (SEM were used for data analysis. It was considered that certain criteria of reliability measures were met. There was no significant difference between the repetitions, which may be explained by an effect of the evaluator, the ability of the players or fatigue (p > 0.05. The ICC average from evaluators was high (0.88. The SEM varied between 0.13 s and 0.49 s. The CV average considering each individual was near 6-7%. These values depended on the condition of measurement. As the FTAP contains some characteristics that create a degree of unpredictability, the same athlete may reach different performance results, increasing variability. An adjustment in the sample, familiarization and careful selection of subjects help to improve this situation and enhance the reliability of the indicators.

  20. Structural Testing of the Blade Reliability Collaborative Effect of Defect Wind Turbine Blades

    Energy Technology Data Exchange (ETDEWEB)

    Desmond, M. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hughes, S. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Paquette, J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-06-08

    Two 8.3-meter (m) wind turbine blades intentionally constructed with manufacturing flaws were tested to failure at the National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL) south of Boulder, Colorado. Two blades were tested; one blade was manufactured with a fiberglass spar cap and the second blade was manufactured with a carbon fiber spar cap. Test loading primarily consisted of flap fatigue loading of the blades, with one quasi-static ultimate load case applied to the carbon fiber spar cap blade. Results of the test program were intended to provide the full-scale test data needed for validation of model and coupon test results of the effect of defects in wind turbine blade composite materials. Testing was part of the Blade Reliability Collaborative (BRC) led by Sandia National Laboratories (SNL). The BRC seeks to develop a deeper understanding of the causes of unexpected blade failures (Paquette 2012), and to develop methods to enable blades to survive to their expected operational lifetime. Recent work in the BRC includes examining and characterizing flaws and defects known to exist in wind turbine blades from manufacturing processes (Riddle et al. 2011). Recent results from reliability databases show that wind turbine rotor blades continue to be a leading contributor to turbine downtime (Paquette 2012).

  1. Reliability of four experimental mechanical pain tests in children

    DEFF Research Database (Denmark)

    Søe, Ann-Britt Langager; Thomsen, Lise L; Tornoe, Birte

    2013-01-01

    In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT) in healthy children. Furthermore, the aim was a...... was also to study the intersession reliability of the following four tests: (1) Total Tenderness Score; (2) PPT; (3) Visual Analog Scale score at suprapressure pain threshold; and (4) area under the curve (stimulus-response functions for pressure versus pain).......In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT) in healthy children. Furthermore, the aim...

  2. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Rosado, P.H.G.; Cunha, P.G. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  3. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    International Nuclear Information System (INIS)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da; Rosado, P.H.G.; Cunha, P.G.

    2017-01-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  4. Comparison of the reliability of parental reporting and the direct test of the Thai Speech and Language Test.

    Science.gov (United States)

    Prathanee, Benjamas; Angsupakorn, Nipa; Pumnum, Tawitree; Seepuaham, Cholada; Jaiyong, Pechcharat

    2012-11-01

    To find reliability of parental or caregiver's report and testing of the Thai Speech and Language Test for Children Aged 0-4 Years Old. Five investigators assessed speech and language abilities from video both contexts: parental or caregivers' report and test forms of Thai Speech and Language Test for Children Aged 0-4 Years Old. Twenty-five normal and 30 children with delayed development or risk for delayed speech and language skills were assessed at age intervals of 3, 6, 9, 12, 15, 18, 24, 30, 36 and 48 months. Reliability of parental or caregivers' testing and reporting was at a moderate level (0.41-0.60). Inter-rater reliability among investigators was excellent (0.86-1.00). The parental or caregivers' report form of the Thai Speech and Language test for Children aged 0-4 years old was an indicator for success at a moderate level. Trained professionals could use both forms of this test as reliable tools at an excellent level.

  5. Resting-state test-retest reliability of a priori defined canonical networks over different preprocessing steps.

    Science.gov (United States)

    Varikuti, Deepthi P; Hoffstaedter, Felix; Genon, Sarah; Schwender, Holger; Reid, Andrew T; Eickhoff, Simon B

    2017-04-01

    Resting-state functional connectivity analysis has become a widely used method for the investigation of human brain connectivity and pathology. The measurement of neuronal activity by functional MRI, however, is impeded by various nuisance signals that reduce the stability of functional connectivity. Several methods exist to address this predicament, but little consensus has yet been reached on the most appropriate approach. Given the crucial importance of reliability for the development of clinical applications, we here investigated the effect of various confound removal approaches on the test-retest reliability of functional-connectivity estimates in two previously defined functional brain networks. Our results showed that gray matter masking improved the reliability of connectivity estimates, whereas denoising based on principal components analysis reduced it. We additionally observed that refraining from using any correction for global signals provided the best test-retest reliability, but failed to reproduce anti-correlations between what have been previously described as antagonistic networks. This suggests that improved reliability can come at the expense of potentially poorer biological validity. Consistent with this, we observed that reliability was proportional to the retained variance, which presumably included structured noise, such as reliable nuisance signals (for instance, noise induced by cardiac processes). We conclude that compromises are necessary between maximizing test-retest reliability and removing variance that may be attributable to non-neuronal sources.

  6. Resting-state test-retest reliability of a priori defined canonical networks over different preprocessing steps

    Science.gov (United States)

    Varikuti, Deepthi P.; Hoffstaedter, Felix; Genon, Sarah; Schwender, Holger; Reid, Andrew T.; Eickhoff, Simon B.

    2016-01-01

    Resting-state functional connectivity analysis has become a widely used method for the investigation of human brain connectivity and pathology. The measurement of neuronal activity by functional MRI, however, is impeded by various nuisance signals that reduce the stability of functional connectivity. Several methods exist to address this predicament, but little consensus has yet been reached on the most appropriate approach. Given the crucial importance of reliability for the development of clinical applications, we here investigated the effect of various confound removal approaches on the test-retest reliability of functional-connectivity estimates in two previously defined functional brain networks. Our results showed that grey matter masking improved the reliability of connectivity estimates, whereas de-noising based on principal components analysis reduced it. We additionally observed that refraining from using any correction for global signals provided the best test-retest reliability, but failed to reproduce anti-correlations between what have been previously described as antagonistic networks. This suggests that improved reliability can come at the expense of potentially poorer biological validity. Consistent with this, we observed that reliability was proportional to the retained variance, which presumably included structured noise, such as reliable nuisance signals (for instance, noise induced by cardiac processes). We conclude that compromises are necessary between maximizing test-retest reliability and removing variance that may be attributable to non-neuronal sources. PMID:27550015

  7. Intra- and interrater reliability of the 'lumbar-locked thoracic rotation test' in competitive swimmers ages 10 through 18 years.

    Science.gov (United States)

    Feijen, Stef; Kuppens, Kevin; Tate, Angela; Baert, Isabel; Struyf, Thomas; Struyf, Filip

    2018-04-17

    Measuring thoracic spine mobility can be of interest to competitive swimmers as it has been associated with shoulder girdle function and scapular position in subjects with and without shoulder pain. At present, no reliability data of thoracic spine mobility measurements are available in the swimming population. This study aims to evaluate the within-session intra- and interrater reliability of the "lumbar-locked rotation test" for thoracic spine rotation in competitive swimmers aged 10 to 18 years. This reliability study is part of a larger prospective cohort study investigating potential risk factors for the development of shoulder pain in competitive swimmers. Within-session, intra- and inter-rater reliability. Competitive swimming clubs in Belgium. 21 competitive swimmers. Intra- and inter-rater reliability of the lumbar-locked thoracic rotation test. Intraclass correlation coefficients (ICCs) ranged from 0.91 (95% CI 0.78 to 0.96) to 0.96 (0.89-0.98) for intra-rater reliability. Results for inter-rater reliability ranged from 0.89 (0.72-0.95) to 0.86 (0.65-0.94) respectively for right and left thoracic rotation. Results suggest good to excellent reliability of the lumbar-locked thoracic rotation test, indicating this test can be used reliably in clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Test - retest reliability of two instruments for measuring public attitudes towards persons with mental illness

    Directory of Open Access Journals (Sweden)

    Leufstadius Christel

    2011-01-01

    Full Text Available Abstract Background Research has identified stigmatization as a major threat to successful treatment of individuals with mental illness. As a consequence several anti-stigma campaigns have been carried out. The results have been discouraging and the field suffers from lack of evidence about interventions that work. There are few reports on psychometric data for instruments used to assess stigma, which thus complicates research efforts. The aim of the present study was to investigate test-retest reliability of the Swedish versions of the questionnaires: FABI and "Changing Minds" and to examine the internal consistency of the two instruments. Method Two instruments, fear and behavioural intentions (FABI and "Changing Minds", used in earlier studies on public attitudes towards persons with mental illness were translated into Swedish and completed by 51 nursing students on two occasions, with an interval of three weeks. Test-retest reliability was calculated by using weighted kappa coefficient and internal consistency using the Cronbach's alpha coefficient. Results Both instruments attain at best moderate test-retest reliability. For the Changing Minds questionnaire almost one fifth (17.9% of the items present poor test-retest reliability and the alpha coefficient for the subscales ranges between 0.19 - 0.46. All of the items in the FABI reach a fair or a moderate agreement between the test and retest, and the questionnaire displays a high internal consistency, alpha 0.80. Conclusions There is a need for development of psychometrically tested instruments within this field of research.

  9. Test-Retest Reliability and Minimal Detectable Change of the D2 Test of Attention in Patients with Schizophrenia.

    Science.gov (United States)

    Lee, Posen; Lu, Wen-Shian; Liu, Chin-Hsuan; Lin, Hung-Yu; Hsieh, Ching-Lin

    2017-12-08

    The d2 Test of Attention (D2) is a commonly used measure of selective attention for patients with schizophrenia. However, its test-retest reliability and minimal detectable change (MDC) are unknown in patients with schizophrenia, limiting its utility in both clinical and research settings. The aim of the present study was to examine the test-retest reliability and MDC of the D2 in patients with schizophrenia. A rater administered the D2 on 108 patients with schizophrenia twice at a 1-month interval. Test-retest reliability was determined through the calculation of the intra-class correlation coefficient (ICC). We also carried out Bland-Altman analysis, which included a scatter plot of the differences between test and retest against their mean. Systematic biases were evaluated by use of a paired t-test. The ICCs for the D2 ranged from 0.78 to 0.94. The MDCs (MDC%) of the seven subscores were 102.3 (29.7), 19.4 (85.0), 7.2 (94.6), 21.0 (69.0), 104.0 (33.1), 105.0 (35.8), and 7.8 (47.8), which represented limited-to-acceptable random measurement error. Trends in the Bland-Altman plots of the omissions (E1), commissions (E2), and errors (E) were noted, presenting that the data had heteroscedasticity. According to the results, the D2 had good test-retest reliability, especially in the scores of TN, TN-E, and CP. For the further research, finding a way to improve the administration procedure to reduce random measurement error would be important for the E1, E2, E, and FR subscores. © The Author(s) 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Online cognition : Factors facilitating reliable online neuropsychological test results

    NARCIS (Netherlands)

    Feenstra, H.E.M.; Vermeulen, I.E.; Murre, J.M.J.; Schagen, S.B.

    2017-01-01

    OBJECTIVE: Online neuropsychological test batteries could allow for large-scale cognitive data collection in clinical studies. However, the few online neuropsychological test batteries that are currently available often still require supervision or lack proper psychometric evaluation. In this paper,

  11. Online cognition : factors facilitating reliable online neuropsychological test results

    NARCIS (Netherlands)

    Feenstra, Heleen E M; Vermeulen, Ivar E; Murre, Jaap M J; Schagen, Sanne B

    OBJECTIVE: Online neuropsychological test batteries could allow for large-scale cognitive data collection in clinical studies. However, the few online neuropsychological test batteries that are currently available often still require supervision or lack proper psychometric evaluation. In this paper,

  12. Validity and reliability of the 10-m walk test and the 6-min walk test in spinal cord injury patients.

    Science.gov (United States)

    Scivoletto, G; Tamburella, F; Laurenza, L; Foti, C; Ditunno, J F; Molinari, M

    2011-06-01

    The 10-m walk test (10MWT) and the 6-min walk test (6MWT) have been recommended for assessment of walking in spinal cord injury (SCI) patients. The study was designed on test-retest analysis of the 10MWT and 6MWT. The objective of this study was to assess validity/reliability of different methods of performing the tests. The study was set at an SCI unit of a rehabilitation hospital. A total of 37 patients; whose median age was 58.5 years (interquartile range 40-66, full range 19-77); median time since onset of SCI was 24 months (interquartile range 16.25-70.5, full range 6-109). Non-traumatic etiology in 20 out of 37 patients; level: 12C, 14T and 11L; American Spinal Injury Association Impairment Scale grade: 35D/2C. Assessment with the 10MWT (with or without dynamic start) and the 6MWT (short or long track) by two blinded raters to evaluate inter/intra-rater reliabilities. The 10MWT was performed in a median of 19 s (25th-75th interquartile range 13-28) with the dynamic start and of 18.4 s (25th-75th interquartile range 12.6-29.9) with the static start (P=0.092). The correlation between the results of the two methods was between 0.98 and 0.99. The inter- and intra-rater reliabilities were between 0.95 and 0.99 for both the methods. The 6MWT showed significant differences according to the track length: patients walked a median of 226.7 m (25th-75th interquartile range 123.2-319) on the longer track and of 187.6 m (25th-75th interquartile range 69.7-240.6) on the short one (P<0.001). The correlation between the results of the two methods was between 0.91 and 0.93. The inter- and intra-rater reliabilities were between 0.98 and 0.99. The 10MWT shows high inter/intra-rater reliability and shows comparable results with both dynamic and static start. The different testing conditions of the 6MWT (track/turns) results in significant differences that need standardization for use in future trials.

  13. Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test Report

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan; Wallen, Robb

    2015-06-10

    Many gearboxes in wind turbines have not been achieving their expected design life [1]; they do, however, commonly meet or exceed the design criteria specified in current standards in the gear, bearing, and wind turbine industry as well as third-party certification criteria. The cost of gearbox replacements and rebuilds, as well as the downtime associated with these failures, has elevated the cost of wind energy. In 2006, the U.S. Department of Energy established the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC). Its key goal is to understand the root causes of premature gearbox failures and improve their reliability [2]. The GRC is examining a hypothesis that the gap between design-estimated and actual wind turbine gearbox reliability is caused by underestimation of loads, inaccurate design tools, the absence of critical elements in the design process, or insufficient testing. This test report describes the recent tests of GRC gearbox (GB) 2 in the National Wind Technology Center (NWTC) dynamometer and documents any modifications to the original test plan [3]. In this manner, it serves as a guide for interpreting the publicly released data sets with brief analyses to illustrate the data. Specific objectives of the test were to assess the effect of dynamic nontorque load (NTL) on the planetary section, generator misalignment on the highspeed shaft (HSS), and field representative conditions on the gearbox in general. Detailed analysis of those test objectives will be presented in subsequent publications.

  14. Reliability of Health-Related Physical Fitness Tests among Colombian Children and Adolescents: The FUPRECOL Study.

    Directory of Open Access Journals (Sweden)

    Robinson Ramírez-Vélez

    Full Text Available Substantial evidence indicates that youth physical fitness levels are an important marker of lifestyle and cardio-metabolic health profiles and predict future risk of chronic diseases. The reliability physical fitness tests have not been explored in Latino-American youth population. This study's aim was to examine the reliability of health-related physical fitness tests that were used in the Colombian health promotion "Fuprecol study". Participants were 229 Colombian youth (boys n = 124 and girls n = 105 aged 9 to 17.9 years old. Five components of health-related physical fitness were measured: 1 morphological component: height, weight, body mass index (BMI, waist circumference, triceps skinfold, subscapular skinfold, and body fat (% via impedance; 2 musculoskeletal component: handgrip and standing long jump test; 3 motor component: speed/agility test (4x10 m shuttle run; 4 flexibility component (hamstring and lumbar extensibility, sit-and-reach test; 5 cardiorespiratory component: 20-meter shuttle-run test (SRT to estimate maximal oxygen consumption. The tests were performed two times, 1 week apart on the same day of the week, except for the SRT which was performed only once. Intra-observer technical errors of measurement (TEMs and inter-rater (reliability were assessed in the morphological component. Reliability for the Musculoskeletal, motor and cardiorespiratory fitness components was examined using Bland-Altman tests. For the morphological component, TEMs were small and reliability was greater than 95% of all cases. For the musculoskeletal, motor, flexibility and cardiorespiratory components, we found adequate reliability patterns in terms of systematic errors (bias and random error (95% limits of agreement. When the fitness assessments were performed twice, the systematic error was nearly 0 for all tests, except for the sit and reach (mean difference: -1.03% [95% CI = -4.35% to -2.28%]. The results from this study indicate that the

  15. Reliable and sensitive physical testing of elite trapeze sailors

    DEFF Research Database (Denmark)

    Bay, Jonathan; Bojsen-Møller, Jens; Nordsborg, Nikolai Baastrup

    2018-01-01

    It was investigated, if a newly developed discipline specific test for elite-level trapeze sailors is reli-able and sensitive. Furthermore, the physical demands of trapeze sailing were examined. In part 1, nine national team athletes were accustomed to a simulated sailing test, which subsequently....... 265 ± 45W, Psailing was 54.5 ± 7.2% VO2max , 75.1 ± 3.1% HRmax and 5.8 ± 2.7 mM, respectively. However, VO2 and HR were substantially higher for periods of the race...... as peak values were 83.5 ± 11.4% and 89.9 ± 1.7% of max, respectively. In conclusion, the present test is reliable and sensitive, thus providing a sailing specific alternative to traditional physical testing of elite trapeze sailors. Additionally, on-water rac-ing requires moderate aerobic energy...

  16. Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Pensinger, Stuart; Sargusingh, Miriam J.

    2014-01-01

    The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

  17. Evidences of validity and reliability of the Luria-Nebraska Test for Children

    Directory of Open Access Journals (Sweden)

    Ricardo Franco de Lima

    2016-01-01

    Full Text Available Abstract This paper aimed to verify evidences of validity and reliability of Luria-Nebraska Test for Children (TLN-C, in Portuguese. Three hundred eighty-seven students aged 6–13 years old, with learning difficulties, comprised the study. They were assessed with the Wechsler Intelligence Scale for Children (WISC-III and TLN-C; and effect of age differences, as well as accuracy rating by internal consistency were investigated. Age effects were found for all subtests and in the general score, except for receptive speech subtest, even when total IQ effect was controlled. Reliability analysis had satisfactory results (0.79. The TLN-C showed evidences of validity and reliability. Receptive speech subtest requires revision.

  18. Test-retest reliability of the 40 Hz EEG auditory steady-state response.

    Directory of Open Access Journals (Sweden)

    Kristina L McFadden

    Full Text Available Auditory evoked steady-state responses are increasingly being used as a marker of brain function and dysfunction in various neuropsychiatric disorders, but research investigating the test-retest reliability of this response is lacking. The purpose of this study was to assess the consistency of the auditory steady-state response (ASSR across sessions. Furthermore, the current study aimed to investigate how the reliability of the ASSR is impacted by stimulus parameters and analysis method employed. The consistency of this response across two sessions spaced approximately 1 week apart was measured in nineteen healthy adults using electroencephalography (EEG. The ASSR was entrained by both 40 Hz amplitude-modulated white noise and click train stimuli. Correlations between sessions were assessed with two separate analytical techniques: a channel-level analysis across the whole-head array and b signal-space projection from auditory dipoles. Overall, the ASSR was significantly correlated between sessions 1 and 2 (p<0.05, multiple comparison corrected, suggesting adequate test-retest reliability of this response. The current study also suggests that measures of inter-trial phase coherence may be more reliable between sessions than measures of evoked power. Results were similar between the two analysis methods, but reliability varied depending on the presented stimulus, with click train stimuli producing more consistent responses than white noise stimuli.

  19. Application of a truncated normal failure distribution in reliability testing

    Science.gov (United States)

    Groves, C., Jr.

    1968-01-01

    Statistical truncated normal distribution function is applied as a time-to-failure distribution function in equipment reliability estimations. Age-dependent characteristics of the truncated function provide a basis for formulating a system of high-reliability testing that effectively merges statistical, engineering, and cost considerations.

  20. Reliability of the Handgrip Strength Test in Elderly Subjects With Parkinson Disease.

    Science.gov (United States)

    Villafañe, Jorge H; Valdes, Kristin; Buraschi, Riccardo; Martinelli, Marco; Bissolotti, Luciano; Negrini, Stefano

    2016-03-01

    The handgrip strength test is widely used by clinicians; however, little has been investigated about its reliability when used in subjects with Parkinson disease (PD). The purpose of this study was to investigate the test-retest reliability of the handgrip strength test for subjects with PD. The PD group consisted of 15 patients, and the control group consisted of 15 healthy subjects. Each patient performed 3 pain-free maximal isometric contractions on each hand on 2 occasions, 1 week apart. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and 95% limits of agreement (LOA) were calculated. The 2-way analysis of variance (ANOVA) was conducted to determine the differences between sides and groups. Test-retest reliability of measurements of grip strength was excellent for dominant (ICC = 0.97; P = .001) and non-dominant (ICC = 0.98; P = .001) hand of participant with PD and (ICC = 0.99; P = .001) and (ICC = 0.99; P = .001) respectively, of healthy group. The Jamar hand dynamometer had fair to excellent test-retest reliability to test grip strength in participants with PD.

  1. Validity and test-retest reliability of a novel simple back extensor muscle strength test.

    Science.gov (United States)

    Harding, Amy T; Weeks, Benjamin Kurt; Horan, Sean A; Little, Andrew; Watson, Steven L; Beck, Belinda Ruth

    2017-01-01

    To develop and determine convergent validity and reliability of a simple and inexpensive clinical test to quantify back extensor muscle strength. Two testing sessions were conducted, 7 days apart. Each session involved three trials of standing maximal isometric back extensor muscle strength using both the novel test and isokinetic dynamometry. Lumbar spine bone mineral density was examined by dual-energy X-ray absorptiometry. Validation was examined with Pearson correlations ( r ). Test-retest reliability was examined with intraclass correlation coefficients and limits of agreement. Pearson correlations and intraclass correlation coefficients are presented with corresponding 95% confidence intervals. Linear regression was used to examine the ability of peak back extensor muscle strength to predict indices of lumbar spine bone mineral density and strength. A total of 52 healthy adults (26 men, 26 women) aged 46.4 ± 20.4 years were recruited from the community. A strong positive relationship was observed between peak back extensor strength from hand-held and isokinetic dynamometry ( r  = 0.824, p  strength test, short- and long-term reliability was excellent (intraclass correlation coefficient = 0.983 (95% confidence interval, 0.971-0.990), p  strength measures with the novel back extensor strength protocol were -6.63 to 7.70 kg, with a mean bias of +0.71 kg. Back extensor strength predicted 11% of variance in lumbar spine bone mineral density ( p  strength ( p  strength is quick, relatively inexpensive, and reliable; demonstrates initial convergent validity in a healthy population; and is associated with bone mass at a clinically important site.

  2. Intra- and inter-rater reliability of movement and palpation tests in patients with neck pain: A systematic review.

    Science.gov (United States)

    Jonsson, Anders; Rasmussen-Barr, Eva

    2018-03-01

    Neck pain is common and often becomes chronic. Various clinical tests of the cervical spine are used to direct and evaluate treatment. This systematic review aimed to identify studies examining the intra- and/or interrater reliability of tests used in clinical examination of patients with neck pain. A database search up to April 2016 was conducted in PubMed, CINAHL, and AMED. The Quality Appraisal of Reliability Studies Checklist (QAREL) was used to assess risk of bias. Eleven studies were included, comprising tests of active and passive movement and pain evaluating participants with ongoing neck pain. One study was assessed with a low risk of bias, three with medium risk, while the rest were assessed with high risk of bias. The results showed differing reliabilities for the included tests ranging from poor to almost perfect. In conclusion, active movement and pain for pain or mobility overall presented acceptable to very good reliability (Kappa >0.40); while passive intervertebral tests had lower Kappa values, suggesting poor reliability. It may be a coincidence that the studies indicating very good reliability tended to be of higher quality (low to moderate risk of bias), while studies finding poor reliability tended to be of lower quality (high risk of bias). Regardless, the current recommendation from this review would suggest the clinical use of tests with acceptable reliability and avoiding the use of tests that have been shown to not be reliable. Finally, it is critical that all future reliability studies are of higher quality with low risk of bias.

  3. Isokinetic Strength and Endurance Tests used Pre- and Post-Spaceflight: Test-Retest Reliability

    Science.gov (United States)

    Laughlin, Mitzi S.; Lee, Stuart M. C.; Loehr, James A.; Amonette, William E.

    2009-01-01

    To assess changes in muscular strength and endurance after microgravity exposure, NASA measures isokinetic strength and endurance across multiple sessions before and after long-duration space flight. Accurate interpretation of pre- and post-flight measures depends upon the reliability of each measure. The purpose of this study was to evaluate the test-retest reliability of the NASA International Space Station (ISS) isokinetic protocol. Twenty-four healthy subjects (12 M/12 F, 32.0 +/- 5.6 years) volunteered to participate. Isokinetic knee, ankle, and trunk flexion and extension strength as well as endurance of the knee flexors and extensors were measured using a Cybex NORM isokinetic dynamometer. The first weekly session was considered a familiarization session. Data were collected and analyzed for weeks 2-4. Repeated measures analysis of variance (alpha=0.05) was used to identify weekly differences in isokinetic measures. Test-retest reliability was evaluated by intraclass correlation coefficients (ICC) (3,1). No significant differences were found between weeks in any of the strength measures and the reliability of the strength measures were all considered excellent (ICC greater than 0.9), except for concentric ankle dorsi-flexion (ICC=0.67). Although a significant difference was noted in weekly endurance measures of knee extension (p less than 0.01), the reliability of endurance measure by week were considered excellent for knee flexion (ICC=0.97) and knee extension (ICC=0.96). Except for concentric ankle dorsi-flexion, the isokinetic strength and endurance measures are highly reliable when following the NASA ISS protocol. This protocol should allow accurate interpretation isokinetic data even with a small number of crew members.

  4. Test-retest reliability of the eating disorder examination-questionnaire (EDE-Q) in a college sample

    OpenAIRE

    Rose, Jennifer S; Vaewsorn, Adin; Rosselli-Navarra, Francine; Wilson, G Terence; Weissman, Ruth Striegel

    2013-01-01

    Background The Eating Disorder Examination-Questionnaire (EDE-Q), a widely used self-report instrument, is often used for measuring change in eating disorder symptoms over the course of treatment. However, limited data exist about test-retest reliability, particularly for men. The current study evaluated EDE-Q 7-day test-retest reliability in male (n = 47) and female (n = 44) undergraduate students together and separately by gender. Results Internal consistency was consistently higher for wom...

  5. Clinical Functional Capacity Testing in Patients With Facioscapulohumeral Muscular Dystrophy: Construct Validity and Interrater Reliability of Antigravity Tests.

    Science.gov (United States)

    Rijken, Noortje H; van Engelen, Baziel G; Weerdesteyn, Vivian; Geurts, Alexander C

    2015-12-01

    To evaluate the construct validity and interrater reliability of 4 simple antigravity tests in a small group of patients with facioscapulohumeral muscular dystrophy (FSHD). Case-control study. University medical center. Patients with various severity levels of FSHD (n=9) and healthy control subjects (n=10) were included (N=19). Not applicable. A 4-point ordinal scale was designed to grade performance on the following 4 antigravity tests: sit to stance, stance to sit, step up, and step down. In addition, the 6-minute walk test, 10-m walking test, Berg Balance Scale, and timed Up and Go test were administered as conventional tests. Construct validity was determined by linear regression analysis using the Clinical Severity Score (CSS) as the dependent variable. Interrater agreement was tested using a κ analysis. Patients with FSHD performed worse on all 4 antigravity tests compared with the controls. Stronger correlations were found within than between test categories (antigravity vs conventional). The antigravity tests revealed the highest explained variance with regard to the CSS (R(2)=.86, P=.014). Interrater agreement was generally good. The results of this exploratory study support the construct validity and interrater reliability of the proposed antigravity tests for the assessment of functional capacity in patients with FSHD taking into account the use of compensatory strategies. Future research should further validate these results in a larger sample of patients with FSHD. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  6. Reproducibility of the results in nondestructive testing

    International Nuclear Information System (INIS)

    Launay, J.P.; Chalaye, H.; Thomas, A.

    1980-10-01

    Pressure vessels must comply with very severe safety criteria. In order to ensure that the required quality is attained, non destructive tests are used and these have to be highly reliable: magnetoscopy and liquid penetration for surface examinations, radiography and ultrasonics for voluminal examinations. In the case of ultrasonic examinations, a study of parameters has been made and a statistical analysis of the results has made it possible to calculate the dispersion due to the testing equipment [fr

  7. Improving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep.

    Science.gov (United States)

    Wang, Jiahui; Han, Junwei; Nguyen, Vinh T; Guo, Lei; Guo, Christine C

    2017-01-01

    Resting state functional magnetic resonance imaging (rs-fMRI) provides a powerful tool to examine large-scale neural networks in the human brain and their disturbances in neuropsychiatric disorders. Thanks to its low demand and high tolerance, resting state paradigms can be easily acquired from clinical population. However, due to the unconstrained nature, resting state paradigm is associated with excessive head movement and proneness to sleep. Consequently, the test-retest reliability of rs-fMRI measures is moderate at best, falling short of widespread use in the clinic. Here, we characterized the effect of sleep on the test-retest reliability of rs-fMRI. Using measures of heart rate variability (HRV) derived from simultaneous electrocardiogram (ECG) recording, we identified portions of fMRI data when subjects were more alert or sleepy, and examined their effects on the test-retest reliability of functional connectivity measures. When volumes of sleep were excluded, the reliability of rs-fMRI is significantly improved, and the improvement appears to be general across brain networks. The amount of improvement is robust with the removal of as much as 60% volumes of sleepiness. Therefore, test-retest reliability of rs-fMRI is affected by sleep and could be improved by excluding volumes of sleepiness as indexed by HRV. Our results suggest a novel and practical method to improve test-retest reliability of rs-fMRI measures.

  8. Maximal cardiorespiratory fitness testing in individuals with chronic stroke with cognitive impairment: practice test effects and test-retest reliability.

    Science.gov (United States)

    Olivier, Charles; Doré, Jean; Blanchet, Sophie; Brooks, Dina; Richards, Carol L; Martel, Guy; Robitaille, Nancy-Michelle; Maltais, Désirée B

    2013-11-01

    To evaluate, for individuals with chronic stroke with cognitive impairment, (1) the effects of a practice test on peak cardiorespiratory fitness test results; (2) cardiorespiratory fitness test-retest reliability; and (3) the relationship between individual practice test effects and cognitive impairment. Cross-sectional. Rehabilitation center. A convenience sample of 21 persons (men [n=12] and women [n=9]; age range, 48-81y; 44.9±36.2mo poststroke) with cognitive impairments who had sufficient lower limb function to perform the test. Not applicable. Peak oxygen consumption (Vo(2)peak, ml·kg(-1)·min(-1)). Test-retest reliability of Vo(2)peak was excellent (intraclass correlation coefficient model 2,1 [ICC2,1]=.94; 95% confidence interval [CI], .86-.98). A paired t test showed that there was no significant difference for the group for Vo(2)peak obtained from 2 symptom-limited cardiorespiratory fitness tests performed 1 week apart on a semirecumbent cycle ergometer (test 2-test 1 difference, -.32ml·kg(-1)·min(-1); 95% CI, -.69 to 1.33ml·kg(-1)·min(-1); P=.512). Individual test-retest differences in Vo(2)peak were, however, positively related to general cognitive function as measured by the Mini-Mental State Examination (ρ=.485; Preliably measured in this group without a practice test. General cognitive function, however, may influence the effect of a practice test in that those with lower general cognitive function appear to respond differently to a practice test than those with higher cognitive function. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. Reliability of the Test of Wheeled Mobility (TOWM) and the Short Wheelie Test

    NARCIS (Netherlands)

    Fliess-Douer, Osnat; Van der Woude, Lucas H. V.; Vanlandewijck, Yves C.

    Objective: To assess the reliability of the Test of Wheeled Mobility (TOWM) and the Wheelie test. Design: Cohort study. Setting: Gymnasium. Participants: Manual wheelchair users (N=30, age 23-53y) with a spinal cord injury. Intervention: Participants performed the 30 skills of the TOWM and the 8

  10. Reliability and number of trials of Y Balance Test in adolescent athletes.

    Science.gov (United States)

    Linek, Pawel; Sikora, Damian; Wolny, Tomasz; Saulicz, Edward

    2017-10-01

    The Star Excursion Balance Test (SEBT) is commonly used to evaluate dynamic equilibrium. The Y Balance Test (Y-BT) is a shortened version of the SEBT where a Y- Balance Kit is commonly used. To date, research concerning the protocol and reliability of the SEBT and Y-BT has been conducted only for adults. The aim of the study was to assess the protocol (the necessary number of trials to stabilize the results) and reliability of the Y-BT in adolescent athletes. One-way repeated-measures analysis of variance (ANOVA) and reliability study. The sample of 38 athletes (mean age: 15.6 years) was selected from a football club. A Y-Balance test kit was applied for the evaluation of dynamic balance. The analysis used the values normalized to the relative length of the lower limbs. After six attempts, three consecutive ones achieved stability for all directions and both extremities (p > 0.05). The intraclass correlation coefficient (ICC 3,1 ), standard error of measurement and minimal detectable change values for the three attempts ranged from 0.57 to 0.82, from 3 to less than 6% and from 7.68 to 13.7%, respectively. In the study of adolescent dynamic equilibrium using the Y-BT, it is recommended to perform nine attempts (including six trial attempts and three measurements). In order to increase reliability it is recommended that the average of the three measured attempts is analysed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Intra and Inter-Rater Reliability of Screening for Movement Impairments: Movement Control Tests from The Foundation Matrix

    Science.gov (United States)

    Mischiati, Carolina R.; Comerford, Mark; Gosford, Emma; Swart, Jacqueline; Ewings, Sean; Botha, Nadine; Stokes, Maria; Mottram, Sarah L.

    2015-01-01

    Pre-season screening is well established within the sporting arena, and aims to enhance performance and reduce injury risk. With the increasing need to identify potential injury with greater accuracy, a new risk assessment process has been produced; The Performance Matrix (battery of movement control tests). As with any new method of objective testing, it is fundamental to establish whether the same results can be reproduced between examiners and by the same examiner on consecutive occasions. This study aimed to determine the intra-rater test re-test and inter-rater reliability of tests from a component of The Performance Matrix, The Foundation Matrix. Twenty participants were screened by two experienced musculoskeletal therapists using nine tests to assess the ability to control movement during specific tasks. Movement evaluation criteria for each test were rated as pass or fail. The therapists observed participants real-time and tests were recorded on video to enable repeated ratings four months later to examine intra-rater reliability (videos rated two weeks apart). Overall test percentage agreement was 87% for inter-rater reliability; 98% Rater 1, 94% Rater 2 for test re-test reliability; and 75% for real-time versus video. Intraclass-correlation coefficients (ICCs) were excellent between raters (0.81) and within raters (Rater 1, 0.96; Rater 2, 0.88) but poor for real-time versus video (0.23). Reliability for individual components of each test was more variable: inter-rater, 68-100%; intra-rater, 88-100% Rater 1, 75-100% Rater 2; and real-time versus video 31-100%. Cohen’s Kappa values for inter-rater reliability were 0.0-1.0; intra-rater 0.6-1.0 for Rater 1; -0.1-1.0 for Rater 2; and -0.1-1 for real-time versus video. It is concluded that both inter and intra-rater reliability of tests in The Foundation Matrix are acceptable when rated by experienced therapists. Recommendations are made for modifying some of the criteria to improve reliability where

  12. Reliability and maintainability data acquisition in equipment development tests

    International Nuclear Information System (INIS)

    Haire, M.J.; Gift, E.H.

    1983-10-01

    The need for collection of reliability, maintainability, and availability data adds a new dimension to the data acquisition requirements of equipment development tests. This report describes the reliability and maintainability data that are considered necessary to ensure that sufficient and high quality data exist for a comprehensive, quantitative evaluation of equipment and system availability. These necessary data are presented as a set of data collection forms. Three data acquisition forms are discussed: an inventory and technical data form, which is filed by the design engineer when the design is finished or the equipment is received; an event report form, which is completed by the senior test operator at each shutdown; and a maintainability report, which is a collaborative effort between senior operators and lead engineers and is completed on restart. In addition, elements of a reliability, maintainability evaluation program are described. Emphasis is placed on the role of data, its storage, and use in such a program

  13. Diagnosis of carpal tunnel syndrome: interobserver reliability of the blinded scratch-collapse test

    NARCIS (Netherlands)

    Blok, Robin D.; Becker, Stéphanie J. E.; Ring, David C.

    2014-01-01

    The reliability of the scratch-collapse test for diagnosis of carpal tunnel syndrome (CTS) has not been tested by independent investigators. This study measured the reliability of the scratch-collapse test comparing the treating hand surgeon and blinded evaluators. We performed a prospective

  14. [Reliability and validity of the Chinese version on Alcohol Use Disorders Identification Test].

    Science.gov (United States)

    Zhang, C; Yang, G P; Li, Z; Li, X N; Li, Y; Hu, J; Zhang, F Y; Zhang, X J

    2017-08-10

    Objective: To assess the reliability and validity of the Chinese version on Alcohol Use Disorders Identification Test (AUDIT) among medical students in China and to provide correct way of application on the recommended scales. Methods: An E-questionnaire was developed and sent to medical students in five different colleges. Students were all active volunteers to accept the testings. Cronbach's α and split-half reliability were calculated to evaluate the reliability of AUDIT while content, contract, discriminant and convergent validity were performed to measure the validity of the scales. Results: The overall Cronbach's α of AUDIT was 0.782 and the split-half reliability was 0.711. Data showed that the domain Cronbach's α and split-half reliability were 0.796 and 0.794 for hazardous alcohol use, 0.561 and 0.623 for dependence symptoms, and 0.647 and 0.640 for harmful alcohol use. Results also showed that the content validity index on the levels of items I-CVI) were from 0.83 to 1.00, the content validity index of scale level (S-CVI/UA) was 0.90, content validity index of average scale level (S-CVI/Ave) was 0.99 and the content validity ratios (CVR) were from 0.80 to 1.00. The simplified version of AUDIT supported a presupposed three-factor structure which could explain 61.175% of the total variance revealed through exploratory factor analysis. AUDIT semed to have good convergent and discriminant validity, with the success rate of calibration experiment as 100%. Conclusion: AUDIT showed good reliability and validity among medical students in China thus worth for promotion on its use.

  15. Stand development and reliability tests of the thermal monitoring means for NPP

    International Nuclear Information System (INIS)

    Nalivaev, V.I.; Nikul'shin, V.S.; Kichigin, A.B.; Dirin, V.F.

    2003-01-01

    The paper is devoted to the reliability tests of thermoelectric thermometers and resistance thermometers during their operation in the nominal mode. Five stands Reliability are developed and operate for realization of tests of all manufactured thermal converters. delivered at NPP. Description of all stands are presented [ru

  16. [Testing reliability and validity of reduced substitutes for leadership scales(rd-SLS)].

    Science.gov (United States)

    Kim, Jeong-Hee

    2005-10-01

    This paper was conducted to test the reliability and validity of rd-SLS, developed by Podsakoff, et al. (1993) which measured 'substitutes for leadership'. The subjects were 345 nurses in 5 general hospitals. Cronbach's and the Guttman split-half coefficient were used to test the reliability of rd-SLS. Factor analysis, and the correlations of the rv-SLS and SLS with rd-SLS were used for convergent and discriminant validity. Cronbach's data was 0.76 and the Guttman split-half coefficient was 0.52. Twelve factors evolved by factor analysis, which explained 70.4% of the total variance. This result was similar to previous study results. However, 'Indifference toward organizational rewards'-related items were classified two factors. It was not clear t hat the rd-SLS consisted of 13 concepts(factors). The correlations of the rv-SLS and SLS with the rd-SLS were 0.93 and 0.87 respectively. The rd-SLS showed a moderate degree of validity and reliability. Thus, it is recommended to use the rd-SLS in general nursing organizations for screening for leadership substitutes. In addition, it is necessary to clarify the concept of organizational rewards. In a further study, the factor structure of the rd-SLS may be considered.

  17. Validity and Reliability of Published Comprehensive Theory of Mind Tests for Normal Preschool Children: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Seyyede Zohreh Ziatabar Ahmadi

    2015-12-01

    Full Text Available Objective: Theory of mind (ToM or mindreading is an aspect of social cognition that evaluates mental states and beliefs of oneself and others. Validity and reliability are very important criteria when evaluating standard tests; and without them, these tests are not usable. The aim of this study was to systematically review the validity and reliability of published English comprehensive ToM tests developed for normal preschool children.Method: We searched MEDLINE (PubMed interface, Web of Science, Science direct, PsycINFO, and also evidence base Medicine (The Cochrane Library databases from 1990 to June 2015. Search strategy was Latin transcription of ‘Theory of Mind’ AND test AND children. Also, we manually studied the reference lists of all final searched articles and carried out a search of their references. Inclusion criteria were as follows: Valid and reliable diagnostic ToM tests published from 1990 to June 2015 for normal preschool children; and exclusion criteria were as follows: the studies that only used ToM tests and single tasks (false belief tasks for ToM assessment and/or had no description about structure, validity or reliability of their tests. Methodological quality of the selected articles was assessed using the Critical Appraisal Skills Programme (CASP.Result: In primary searching, we found 1237 articles in total databases. After removing duplicates and applying all inclusion and exclusion criteria, we selected 11 tests for this systematic review. Conclusion: There were a few valid, reliable and comprehensive ToM tests for normal preschool children. However, we had limitations concerning the included articles. The defined ToM tests were different in populations, tasks, mode of presentations, scoring, mode of responses, times and other variables. Also, they had various validities and reliabilities. Therefore, it is recommended that the researchers and clinicians select the ToM tests according to their psychometric

  18. Multi-bundle shashlik calorimeter prototypes beam-test results

    International Nuclear Information System (INIS)

    Badier, J.; Bloch, P.; Bityukov, S.; Bordalo, P.; Busson, P.; Charlot, C.; Dobrzynski, L.; Golutvin, I.; Guschin, E.; Issakov, V.; Ivanchenko, I.; Klimenko, V.; Marin, V.; Moissenz, P.; Obraztsov, V.; Ostankov, A.; Popov, V.; Puljak, I.; Ramos, S.; Seez, C.; Sergueev, S.; Soushkov, V.; Tanaka, R.; Varela, J.; Virdee, T.S.; Zaitchenko, A.; Zamiatin, N.

    1995-01-01

    The first beam-test results for two- and three-bundle shashlik tower prototypes are described. We found that the spatial resolution, the uniformity of energy response, the calorimeter reliability and hermeticity and also two showers separation are improved in multi-bundle design approach. ((orig.))

  19. Reliability of physical functioning tests in patients with low back pain: a systematic review.

    Science.gov (United States)

    Denteneer, Lenie; Van Daele, Ulrike; Truijen, Steven; De Hertogh, Willem; Meirte, Jill; Stassijns, Gaetane

    2018-01-01

    The aim of this study was to provide a comprehensive overview of physical functioning tests in patients with low back pain (LBP) and to investigate their reliability. A systematic computerized search was finalized in four different databases on June 24, 2017: PubMed, Web of Science, Embase, and MEDLINE. Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed during all stages of this review. Clinical studies that investigate the reliability of physical functioning tests in patients with LBP were eligible. The methodological quality of the included studies was assessed with the use of the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) checklist. To come to final conclusions on the reliability of the identified clinical tests, the current review assessed three factors, namely, outcome assessment, methodological quality, and consistency of description. A total of 20 studies were found eligible and 38 clinical tests were identified. Good overall test-retest reliability was concluded for the extensor endurance test (intraclass correlation coefficient [ICC]=0.93-0.97), the flexor endurance test (ICC=0.90-0.97), the 5-minute walking test (ICC=0.89-0.99), the 50-ft walking test (ICC=0.76-0.96), the shuttle walk test (ICC=0.92-0.99), the sit-to-stand test (ICC=0.91-0.99), and the loaded forward reach test (ICC=0.74-0.98). For inter-rater reliability, only one test, namely, the Biering-Sörensen test (ICC=0.88-0.99), could be concluded to have an overall good inter-rater reliability. None of the identified clinical tests could be concluded to have a good intrarater reliability. Further investigation should focus on a better overall study methodology and the use of identical protocols for the description of clinical tests. The assessment of reliability is only a first step in the recommendation process for the use of clinical tests. In future research, the identified clinical tests in the

  20. Intertester reliability of clinical shoulder instability and laxity tests in subjects with and without self-reported shoulder problems.

    Science.gov (United States)

    Eshoj, Henrik; Ingwersen, Kim Gordon; Larsen, Camilla Marie; Kjaer, Birgitte Hougs; Juul-Kristensen, Birgit

    2018-03-03

    First, to investigate the intertester reliability of clinical shoulder instability and laxity tests, and second, to describe the mutual dependency of each test evaluated by each tester for identifying self-reported shoulder instability and laxity. A standardised protocol for conducting reliability studies was used to test the intertester reliability of the six clinical shoulder instability and laxity tests: apprehension, relocation, surprise, load-and-shift, sulcus sign and Gagey. Cohen's kappa (κ) with 95% CIs besides prevalence-adjusted and bias-adjusted kappa (PABAK), accounting for insufficient prevalence and bias, were computed to establish the intertester reliability and mutual dependency. Forty individuals (13 with self-reported shoulder instability and laxity-related shoulder problems and 27 normal shoulder individuals) aged 18-60 were included. Fair (relocation), moderate (load-and-shift, sulcus sign) and substantial (apprehension, surprise, Gagey) intertester reliability were observed across tests (κ 0.39-0.73; 95% CI 0.00 to 1.00). PABAK improved reliability across tests, resulting in substantial to almost perfect intertester reliability for the apprehension, surprise, load-and-shift and Gagey tests (κ 0.65-0.90). Mutual dependencies between each test and self-reported shoulder problem showed apprehension, relocation and surprise to be the most often used tests to characterise self-reported shoulder instability and laxity conditions. Four tests (apprehension, surprise, load-and-shift and Gagey) out of six were considered intertester reliable for clinical use, while relocation and sulcus sign tests need further standardisation before acceptable evidence. Furthermore, the validity of the tests for shoulder instability and laxity needs to be studied. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Reliability of Single-Leg Balance and Landing Tests in Rugby Union; Prospect of Using Postural Control to Monitor Fatigue.

    Science.gov (United States)

    Troester, Jordan C; Jasmin, Jason G; Duffield, Rob

    2018-06-01

    The present study examined the inter-trial (within test) and inter-test (between test) reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA). Twenty-four players undertook test - re-test measures on two occasions (7 days apart) on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13%) for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13%) was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%). Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%). Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%). Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union.

  2. Reliability of Single-Leg Balance and Landing Tests in Rugby Union; Prospect of Using Postural Control to Monitor Fatigue

    Directory of Open Access Journals (Sweden)

    Jordan C. Troester, Jason G. Jasmin, Rob Duffield

    2018-06-01

    Full Text Available The present study examined the inter-trial (within test and inter-test (between test reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA. Twenty-four players undertook test – re-test measures on two occasions (7 days apart on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13% for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13% was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%. Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%. Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%. Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union.

  3. Applications of majorization and Schur functions in reliability and life testing

    International Nuclear Information System (INIS)

    Proschan, F.

    1975-01-01

    This is an expository paper presenting basic definitions and properties of majorization and Schur functions, and displaying a variety of applications of these concepts in reliability prediction and modelling, and in reliability inference and life testing

  4. Validity and Reliability Study of the Korean Tinetti Mobility Test for Parkinson's Disease.

    Science.gov (United States)

    Park, Jinse; Koh, Seong-Beom; Kim, Hee Jin; Oh, Eungseok; Kim, Joong-Seok; Yun, Ji Young; Kwon, Do-Young; Kim, Younsoo; Kim, Ji Seon; Kwon, Kyum-Yil; Park, Jeong-Ho; Youn, Jinyoung; Jang, Wooyoung

    2018-01-01

    Postural instability and gait disturbance are the cardinal symptoms associated with falling among patients with Parkinson's disease (PD). The Tinetti mobility test (TMT) is a well-established measurement tool used to predict falls among elderly people. However, the TMT has not been established or widely used among PD patients in Korea. The purpose of this study was to evaluate the reliability and validity of the Korean version of the TMT for PD patients. Twenty-four patients diagnosed with PD were enrolled in this study. For the interrater reliability test, thirteen clinicians scored the TMT after watching a video clip. We also used the test-retest method to determine intrarater reliability. For concurrent validation, the unified Parkinson's disease rating scale, Hoehn and Yahr staging, Berg Balance Scale, Timed-Up and Go test, 10-m walk test, and gait analysis by three-dimensional motion capture were also used. We analyzed receiver operating characteristic curve to predict falling. The interrater reliability and intrarater reliability of the Korean Tinetti balance scale were 0.97 and 0.98, respectively. The interrater reliability and intra-rater reliability of the Korean Tinetti gait scale were 0.94 and 0.96, respectively. The Korean TMT scores were significantly correlated with the other clinical scales and three-dimensional motion capture. The cutoff values for predicting falling were 14 points (balance subscale) and 10 points (gait subscale). We found that the Korean version of the TMT showed excellent validity and reliability for gait and balance and had high sensitivity and specificity for predicting falls among patients with PD.

  5. A reliable unipedal stance test for the assessment of balance using a force platform.

    Science.gov (United States)

    Ponce-González, J G; Sanchis-Moysi, J; González-Henriquez, J J; Arteaga-Ortiz, R; Calbet, J A L; Dorado, C

    2014-02-01

    The aim was to develop a unipedal stance test for the assessment of balance using a force platform. A single-leg balance test was conducted in 23 students (mean ± SD) age: 23 ± 3 years) in a standard position limiting the movement of the arms and non-supporting leg. Six attempts, with both the jumping (JL) and the contralateral leg (CL), were performed under 3 conditions: 1) eyes opened; 2) eyes closed; 3) eyes opened and executing a precision task. The same protocol was repeated two-week apart. The mean and the best result of the six attempts performed each day were taken as representative of balance. The speed of the centre of pressure (CP-Speed) showed excellent reliability for the "best result" analysis in all tests (ICCs 0.87-0.97), except in the test with the eyes closed performed on the CL (ICCtest. The single-leg stance balance test proposed is a reliable method to assess balance, especially when performed in a static position, with the eyes opened and using the best result of six attempts as reference, independently of the stance leg.

  6. A RELIABILITY TEST USED FOR THE DEVELOPMENT OF A LOYALTY SCALE

    Directory of Open Access Journals (Sweden)

    Florin-Alexandru LUCA

    2017-06-01

    Full Text Available The development of a loyalty model involves the construction of a proper research instrument. For the loyalty model of the clients for financial services, the pre-testing of the research questionnaire represents a significant stage. This article presents the methodology used in this stage for testing the reliability of a loyalty scale. Firstly, this implies choosing the appropriate scales for each variable included in the suggested research model. Secondly, the internal consistency for each of these scales is measured as an indicator of their reliability. The reliability analysis described represents an essential stage in building a measurement instrument for a loyalty model.

  7. The role of test-retest reliability in measuring individual and group differences in executive functioning.

    Science.gov (United States)

    Paap, Kenneth R; Sawi, Oliver

    2016-12-01

    Studies testing for individual or group differences in executive functioning can be compromised by unknown test-retest reliability. Test-retest reliabilities across an interval of about one week were obtained from performance in the antisaccade, flanker, Simon, and color-shape switching tasks. There is a general trade-off between the greater reliability of single mean RT measures, and the greater process purity of measures based on contrasts between mean RTs in two conditions. The individual differences in RT model recently developed by Miller and Ulrich was used to evaluate the trade-off. Test-retest reliability was statistically significant for 11 of the 12 measures, but was of moderate size, at best, for the difference scores. The test-retest reliabilities for the Simon and flanker interference scores were lower than those for switching costs. Standard practice evaluates the reliability of executive-functioning measures using split-half methods based on data obtained in a single day. Our test-retest measures of reliability are lower, especially for difference scores. These reliability measures must also take into account possible day effects that classical test theory assumes do not occur. Measures based on single mean RTs tend to have acceptable levels of reliability and convergent validity, but are "impure" measures of specific executive functions. The individual differences in RT model shows that the impurity problem is worse than typically assumed. However, the "purer" measures based on difference scores have low convergent validity that is partly caused by deficiencies in test-retest reliability. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Improving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep

    Directory of Open Access Journals (Sweden)

    Jiahui Wang

    2017-05-01

    Full Text Available Resting state functional magnetic resonance imaging (rs-fMRI provides a powerful tool to examine large-scale neural networks in the human brain and their disturbances in neuropsychiatric disorders. Thanks to its low demand and high tolerance, resting state paradigms can be easily acquired from clinical population. However, due to the unconstrained nature, resting state paradigm is associated with excessive head movement and proneness to sleep. Consequently, the test-retest reliability of rs-fMRI measures is moderate at best, falling short of widespread use in the clinic. Here, we characterized the effect of sleep on the test-retest reliability of rs-fMRI. Using measures of heart rate variability (HRV derived from simultaneous electrocardiogram (ECG recording, we identified portions of fMRI data when subjects were more alert or sleepy, and examined their effects on the test-retest reliability of functional connectivity measures. When volumes of sleep were excluded, the reliability of rs-fMRI is significantly improved, and the improvement appears to be general across brain networks. The amount of improvement is robust with the removal of as much as 60% volumes of sleepiness. Therefore, test-retest reliability of rs-fMRI is affected by sleep and could be improved by excluding volumes of sleepiness as indexed by HRV. Our results suggest a novel and practical method to improve test-retest reliability of rs-fMRI measures.

  9. CERN Technical training 2008 - Learning for the LHC: Special Workshop demonstrating reliability with accelerated testing

    CERN Multimedia

    2008-01-01

    Larry Edson’s workshop will show examples of quantitative reliability predictions based upon accelerated testing and demonstrates that reliability testing during the prototyping phase will help ascertain product shortcomings. When these weak points are addressed and the redesigned product is re-tested, the reliability of that product will become much higher. These methodologies successfully used in industry might be exceedingly useful also for component development in particle physics where reliability is of utmost importance. This training will provide participants with the skills necessary to demonstrate reliability requirements using accelerated testing methods. The workshop will focus on accelerated test design that employs increased stress levels. This approach has the advantage of reducing test time, sample size and test facility resources. The methodologies taught are applicable to all types of stresses, spanning the electro...

  10. CERN Technical training 2008 - Learning for the LHC: Special Workshop demonstrating reliability with accelerated testing

    CERN Multimedia

    2008-01-01

    Larry Edson’s workshop will show examples of quantitative reliability predictions based upon accelerated testing and demonstrate that reliability testing during the prototyping phase will help ascertain product shortcomings. When these weak points are addressed and the redesigned product is re-tested, the reliability of that product will become much higher. These methodologies successfully used in industry might be exceedingly useful also for component development in particle physics where reliability is of the utmost importance. This training will provide participants with the skills necessary to demonstrate reliability requirements using accelerated testing methods. The workshop will focus on accelerated test design that employs increased stress levels. This approach has the advantage of reducing test time, sample size and test facility resources. The methodologies taught are applicable to all types of stresses, spanning the elec...

  11. CERN Technical training 2008 - Learning for the LHC: Special workshop demonstrating reliability with accelerated testing

    CERN Multimedia

    2008-01-01

    Larry Edson’s workshop will show examples of quantitative reliability predictions based upon accelerated testing and demonstrate that reliability testing during the prototyping phase will help ascertain product shortcomings. When these weak points are addressed and the redesigned product is re-tested, the reliability of that product will become much higher. These methodologies successfully used in industry might be exceedingly useful also for component development in particle physics where reliability is of the utmost importance. This training will provide participants with the skills necessary to demonstrate reliability requirements using accelerated testing methods. The workshop will focus on accelerated test design that employs increased stress levels. This approach has the advantage of reducing test time, sample size and test facility resources. The methodologies taught are applicable to all types of stresses, spanning the elec...

  12. Reliability of psychophysiological responses across multiple motion sickness stimulation tests

    Science.gov (United States)

    Stout, C. S.; Toscano, W. B.; Cowings, P. S.

    1995-01-01

    Although there is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation, very little evidence exists that examines the reproducibility of autonomic responses within subjects during motion sickness stimulation. Our objectives were to examine the reliability of autonomic responses and symptom levels across five testing occasions using the (1) final minute of testing, (2) change in autonomic response and the change in symptom level, and (3) strength of the relationship between the change in symptom level and the change in autonomic responses across the entire motion sickness test. The results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and symptoms throughout the test duration are less stable across the tests. Finally, autonomic responses and symptom levels are significantly related across the entire motion sickness test.

  13. Gearbox Reliability Collaborative Phase 3 Gearbox 3 Test Report

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wallen, Robb [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-02-24

    Many gearboxes in wind turbines do not achieve their expected design life; they do, however, commonly meet or exceed the design criteria specified in current standards in the gear, bearing, and wind turbine industry as well as third-party certification criteria. The cost of gearbox replacements and rebuilds, as well as the downtime associated with these failures, increases the cost of wind energy. In 2007, the U.S. Department of Energy established the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC). Its goals are to understand the root causes of premature gearbox failures and to improve their reliability. The GRC is examining a hypothesis that the gap between design-estimated and actual wind turbine gearbox reliability is caused by underestimation of loads, inaccurate design tools, the absence of critical elements in the design process, or insufficient testing. This report describes the recently completed tests of GRC Gearbox 3 in the National Wind Technology Center dynamometer and documents any modifications to the original test plan. In this manner, it serves as a guide for interpreting the publicly released data sets with brief analyses to illustrate the data. The primary test objective was to measure the planetary load-sharing characteristics in the same conditions as the original GRC gearbox design. If the measured load-sharing characteristics are close to the design model, the projected improvement in planetary section fatigue life and the efficacy of preloaded TRBs in mitigating the planetary bearing fatigue failure mode will have been demonstrated. Detailed analysis of that test objective will be presented in subsequent publications.

  14. Reasoning with Inductive Argument Test: A Study of Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Mehmet Emrah Karadere

    2013-12-01

    Conclusion: The preliminary data obtained from the study of reliability and validity of the scale shows that ‘Reasoning with Inductive Argument Test’ supports reliability and validity in Turkish population. [JCBPR 2013; 2(3.000: 156-161

  15. Assessing high reliability via Bayesian approach and accelerated tests

    International Nuclear Information System (INIS)

    Erto, Pasquale; Giorgio, Massimiliano

    2002-01-01

    Sometimes the assessment of very high reliability levels is difficult for the following main reasons: - the high reliability level of each item makes it impossible to obtain, in a reasonably short time, a sufficient number of failures; - the high cost of the high reliability items to submit to life tests makes it unfeasible to collect enough data for 'classical' statistical analyses. In the above context, this paper presents a Bayesian solution to the problem of estimation of the parameters of the Weibull-inverse power law model, on the basis of a limited number (say six) of life tests, carried out at different stress levels, all higher than the normal one. The over-stressed (i.e. accelerated) tests allow the use of experimental data obtained in a reasonably short time. The Bayesian approach enables one to reduce the required number of failures adding to the failure information the available a priori engineers' knowledge. This engineers' involvement conforms to the most advanced management policy that aims at involving everyone's commitment in order to obtain total quality. A Monte Carlo study of the non-asymptotic properties of the proposed estimators and a comparison with the properties of maximum likelihood estimators closes the work

  16. We need more replication research - A case for test-retest reliability.

    Science.gov (United States)

    Leppink, Jimmie; Pérez-Fuster, Patricia

    2017-06-01

    Following debates in psychology on the importance of replication research, we have also started to see pleas for a more prominent role for replication research in medical education. To enable replication research, it is of paramount importance to carefully study the reliability of the instruments we use. Cronbach's alpha has been the most widely used estimator of reliability in the field of medical education, notably as some kind of quality label of test or questionnaire scores based on multiple items or of the reliability of assessment across exam stations. However, as this narrative review outlines, Cronbach's alpha or alternative reliability statistics may complement but not replace psychometric methods such as factor analysis. Moreover, multiple-item measurements should be preferred above single-item measurements, and when using single-item measurements, coefficients as Cronbach's alpha should not be interpreted as indicators of the reliability of a single item when that item is administered after fundamentally different activities, such as learning tasks that differ in content. Finally, if we want to follow up on recent pleas for more replication research, we have to start studying the test-retest reliability of the instruments we use.

  17. Reliability of Autonomic Responses and Malaise Across Multiple Motion Sickness Stimulation Tests

    Science.gov (United States)

    Stout, Cynthia S.; Toscano, William B.; Cowings, Patricia S.

    1993-01-01

    There is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation. Additionally, a paucity of data exists that examines the variability within an individual across repeated motion sickness tests. Investigators have also examined the relationship of autonomic responses to motion sickness development. These investigations have used analyses at discrete points in time to describe this relationship. This approach fails to address the time course of autonomic responses and malaise development throughout the motion sickness test. Our objectives were to examine the reliability of autonomic responses and malaise using the final minute of the motion sickness test across five testing occasions, to examine the reliability of the change in autonomic responses and the change in malaise across five testing occasions, and to examine the relationship between changes in autonomic responses and changes in malaise level across the entire motion sickness test. Our results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and malaise throughout the test duration were less stable across the tests. We attribute this instability to variations in individual susceptibility and the error associated with estimating a measure of autonomic gain.

  18. Human and organisational factors in the reliability of non-destructive testing (NOT)

    International Nuclear Information System (INIS)

    Norros, L.

    1998-01-01

    Non-destructive testing used in in-service inspections can be seen as a complicated activity system including three mutually related sub-activities: (1) definition of inspection programs and necessary resources, (2) carrying out diagnostic inspections, and (3) interpretation of the results from the view of plant safety and corrective measures. Various studies to investigate and measure the NDT performance have produced disappointing result. No clear correlations between single human factors and performance have been identified even though general agreement exists concerning the significance of human factors to the reliability of testing. Another incentive for our studies has been to test and evaluate the applicability of the international results in the Finnish circumstances. Three successive studies have thus been carried out on the human and organisational factors in non-destructive testing. (author)

  19. "Graded Cycling Test with Talk Test" Is a Reliable Test to Monitor Cardiovascular Fitness in Patients with Minor Stroke

    DEFF Research Database (Denmark)

    Steen Krawcyk, Rikke; Vinther, Anders; Caesar Petersen, Nicolas

    2017-01-01

    variability may challenge currently used cardiovascular monitoring. The Graded Cycling Test with Talk Test is a submaximal exercise test independent of heart rate variability, shown reliable for patients with cardiac disease. METHODS: Patients diagnosed with lacunar stroke according to TOAST (Trial of Org...... a minor measurement error: 12.9 W for groups of patients (standard error of measurement, SEM95) and 18.3 W for individual patients (smallest real difference). CONCLUSION: The "Graded Cycling Test with Talk Test" is feasible and reliable for monitoring exercise effects in patients with lacunar stroke...... 10172 in Acute Stroke Treatment) criteria performed an incremental exercise test on a stationary bicycle with a 15 W (watt) increase in workload every minute. Toward the end of each incremental step, the patients recited a standardized text passage and subsequently were asked: "Are you still able...

  20. Large test rigs verify Clinch River control rod reliability

    International Nuclear Information System (INIS)

    Michael, H.D.; Smith, G.G.

    1983-01-01

    The purpose of the Clinch River control test programme was to use multiple full-scale prototypic control rod systems for verifying the system's ability to perform reliably during simulated reactor power control and emergency shutdown operations. Two major facilities, the Shutdown Control Rod and Maintenance (Scram) facility and the Dynamic and Seismic Test (Dast) facility, were constructed. The test programme of each facility is described. (UK)

  1. Test your memory-Turkish version (TYM-TR): reliability and validity study of a cognitive screening test.

    Science.gov (United States)

    Maviş, Ilknur; Özbabalik Adapinar, Belgin Demet; Yenilmez, Çinar; Aydin, Ayşe; Olgun, Engin; Bal, Cengiz

    2015-01-01

    The test your memory (TYM) is reported to be a sensitive cognitive function assessment scale for people with dementia. The aim of the present study was to investigate the reliability and validity of an adapted Turkish version of the TYM (TYM-TR) among Turkish dementia patients. The TYM-TR was given to 59 patients with dementia aged 60+ and 336 normal controls aged 23-75+. The diagnostic utility of the TYM-TR was compared with that of the mini-mental state examination (MMSE) to validate it. The internal consistency of the TYM-TR was a = 0.85. The test-retest reliability was 0.97 (P reliability and validity to distinguish dementia in the Turkish population.

  2. Reliability Testing Using the Vehicle Durability Simulator

    Science.gov (United States)

    2017-11-20

    techniques are employed to reduce test and simulation time. Through application of these processes and techniques the reliability characteristics...remote parameter control (RPC) software. The software is specifically designed for the data collection, analysis, and simulation processes outlined in...the selection process for determining the desired runs for simulation . 4.3 Drive File Development. After the data have been reviewed and

  3. The Unsupported Upper Limb Exercise Test in People Without Disabilities: Assessing the Within-Day Test-Retest Reliability and the Effects of Age and Gender.

    Science.gov (United States)

    Oliveira, Ana; Cruz, Joana; Jácome, Cristina; Marques, Alda

    2018-01-01

    Purpose: To estimate the within-day test-retest reliability and standard error of measurement (SEM) of the unsupported upper limb exercise test (UULEX) in adults without disabilities and to determine the effects of age and gender on performance of the UULEX. Method: A cross-sectional study was conducted with 100 adults without disabilities (44 men, mean age 44.2 [SD 26] y; 56 women, mean age 38.1 [SD 24.1] y). Participants performed three UULEX tests to establish within-day reliability, measured using an intra-class correlation coefficient (ICC) model 2 (two-way random effects) with a single rater (ICC[2,1]) and SEM. The effects of age and gender were examined using two-factor mixed-design analysis of variance (ANOVA) and one-way repeated-measures ANOVA. For analysis purposes, four sub-groups were created: younger adults, older adults, men, and women. Results: Excellent within-day reliability and a small SEM were found in the four sub-groups (younger adults: ICC[2,1]=0.88; 95% CI: 0.82, 0.92; SEM∼40 s; older adults: ICC[2,1]=0.82; 95% CI: 0.72, 0.90; SEM∼50 s; men: ICC[2,1]=0.93; 95% CI: 0.88, 0.96; SEM∼30 s; women: ICC[2,1]=0.85; 95% CI: 0.78, 0.91; SEM∼45 s). Younger adults took, on average, 308.24 seconds longer than older adults to perform the test; older adults performed significantly better on the third test ( p 0.05). Conclusion: The within-day test-retest reliability and SEM values of the UULEX may be used to define the magnitude of the error obtained with repeated measures. One UULEX test seems to be adequate for younger adults to achieve reliable results, whereas three tests seem to be needed for older adults.

  4. Calf-raise senior: a new test for assessment of plantar flexor muscle strength in older adults: protocol, validity, and reliability.

    Science.gov (United States)

    André, Helô-Isa; Carnide, Filomena; Borja, Edgar; Ramalho, Fátima; Santos-Rocha, Rita; Veloso, António P

    2016-01-01

    This study aimed to develop a new field test protocol with a standardized measurement of strength and power in plantar flexor muscles targeted to functionally independent older adults, the calf-raise senior (CRS) test, and also evaluate its reliability and validity. Forty-one subjects aged 65 years and older of both sexes participated in five different cross-sectional studies: 1) pilot (n=12); 2) inter- and intrarater agreement (n=12); 3) construct (n=41); 4) criterion validity (n=33); and 5) test-retest reliability (n=41). Different motion parameters were compared in order to define a specifically designed protocol for seniors. Two raters evaluated each participant twice, and the results of the same individual were compared between raters and participants to assess the interrater and intrarater agreement. The validity and reliability studies involved three testing sessions that lasted 2 weeks, including a battery of functional fitness tests, CRS test in two occasions, accelerometry, and strength assessments in an isokinetic dynamometer. The CRS test presented an excellent test-retest reliability (intraclass correlation coefficient [ICC] =0.90, standard error of measurement =2.0) and interrater reliability (ICC =0.93-0.96), as well as a good intrarater agreement (ICC =0.79-0.84). Participants with better results in the CRS test were younger and presented higher levels of physical activity and functional fitness. A significant association between test results and all strength parameters (isometric, r =0.87, r 2 =0.75; isokinetic, r =0.86, r 2 =0.74; and rate of force development, r =0.77, r 2 =0.59) was shown. This study was successful in demonstrating that the CRS test can meet the scientific criteria of validity and reliability. The test can be a good indicator of ankle strength in older adults and proved to discriminate significantly between individuals with improved functionality and levels of physical activity.

  5. The six-item Clock Drawing Testreliability and validity in mild Alzheimer’s disease

    DEFF Research Database (Denmark)

    Jørgensen, Kasper; Kristensen, Maria K; Waldemar, Gunhild

    2015-01-01

    This study presents a reliable, short and practical version of the Clock Drawing Test (CDT) for clinical use and examines its diagnostic accuracy in mild Alzheimer's disease versus elderly nonpatients. Clock drawings from 231 participants were scored independently by four clinical neuropsychologi......This study presents a reliable, short and practical version of the Clock Drawing Test (CDT) for clinical use and examines its diagnostic accuracy in mild Alzheimer's disease versus elderly nonpatients. Clock drawings from 231 participants were scored independently by four clinical...... neuropsychologists blind to diagnostic classification. The interrater agreement of individual scoring criteria was analyzed and items with poor or moderate reliability were excluded. The classification accuracy of the resulting scoring system - the six-item CDT - was examined. We explored the effect of further...

  6. Korean round-robin result for new international program to assess the reliability of emerging nondestructive techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Cho; Kim, Jin Gyum; Kang, Sung Sik; Jhung, Myung Jo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2017-04-15

    The Korea Institute of Nuclear Safety, as a representative organization of Korea, in February 2012 participated in an international Program to Assess the Reliability of Emerging Nondestructive Techniques initiated by the U.S. Nuclear Regulatory Commission. The goal of the Program to Assess the Reliability of Emerging Nondestructive Techniques is to investigate the performance of emerging and prospective novel nondestructive techniques to find flaws in nickel-alloy welds and base materials. In this article, Korean round-robin test results were evaluated with respect to the test blocks and various nondestructive examination techniques. The test blocks were prepared to simulate large-bore dissimilar metal welds, small-bore dissimilar metal welds, and bottom-mounted instrumentation penetration welds in nuclear power plants. Also, lessons learned from the Korean round-robin test were summarized and discussed.

  7. Vertical jumping tests in volleyball: reliability, validity, and playing-position specifics.

    Science.gov (United States)

    Sattler, Tine; Sekulic, Damir; Hadzic, Vedran; Uljevic, Ognjen; Dervisevic, Edvin

    2012-06-01

    Vertical jumping is known to be important in volleyball, and jumping performance tests are frequently studied for their reliability and validity. However, most studies concerning jumping in volleyball have dealt with standard rather than sport-specific jumping procedures and tests. The aims of this study, therefore, were (a) to determine the reliability and factorial validity of 2 volleyball-specific jumping tests, the block jump (BJ) test and the attack jump (AJ) test, relative to 2 frequently used and systematically validated jumping tests, the countermovement jump test and the squat jump test and (b) to establish volleyball position-specific differences in the jumping tests and simple anthropometric indices (body height [BH], body weight, and body mass index [BMI]). The BJ was performed from a defensive volleyball position, with the hands positioned in front of the chest. During an AJ, the players used a 2- to 3-step approach and performed a drop jump with an arm swing followed by a quick vertical jump. A total of 95 high-level volleyball players (all men) participated in this study. The reliability of the jumping tests ranged from 0.97 to 0.99 for Cronbach's alpha coefficients, from 0.93 to 0.97 for interitem correlation coefficients and from 2.1 to 2.8 for coefficients of variation. The highest reliability was found for the specific jumping tests. The factor analysis extracted one significant component, and all of the tests were highly intercorrelated. The analysis of variance with post hoc analysis showed significant differences between 5 playing positions in some of the jumping tests. In general, receivers had a greater jumping capacity, followed by libero players. The differences in jumping capacities should be emphasized vis-a-vis differences in the anthropometric measures of players, where middle hitters had higher BH and body weight, followed by opposite hitters and receivers, with no differences in the BMI between positions.

  8. Reliability and normative values of the foot line test: a technique to assess foot posture

    DEFF Research Database (Denmark)

    Brushøj, C; Larsen, Klaus; Nielsen, MB

    2007-01-01

    STUDY DESIGN: Test-retest reliability. OBJECTIVE: To examine the reliability and report normative values of a novel test, the foot line test (FLT), to describe foot morphology. BACKGROUND: Numerous foot examinations are performed each day, but most existing examination techniques have considerable...... limitations regarding reliability and validity. METHODS: One hundred thirty subjects with mean foot size 44 (41-50 European size) participated. Two examiners, blinded to each other's measurements, measured the right foot of the subjects twice and the left foot once. The position of the most medial aspect...... of the navicular in the mediolateral direction was projected vertically onto a piece of paper placed under the subject's foot, and compared to the position of the forefoot and hindfoot to obtain the FLT value. RESULTS: FLT values ranged from -8 to 14 mm, with a mean (+/-SD) of 3.7 +/- 3.4 mm. The intratester...

  9. Seismic proving tests on the reliability for large components and equipment of nuclear power plants

    International Nuclear Information System (INIS)

    Ohno, Tokue; Tanaka, Nagatoshi

    1988-01-01

    Since Japan has destructive earthquakes frequently, the structural reliability for large components and equipment of nuclear power plants are rigorously required. They are designed using sophisticated seismic analyses and have not yet encountered a destructive earthquake. When nuclear power plants are planned, it is very important that the general public understand the structural reliability during and after an earthquake. Seismic Proving Tests have been planned by Ministry of International Trade and Industry (Miti) to comply with public requirement in Japan. A large-scale high-performance vibration table was constructed at Tasted Engineering Laboratory of Nuclear Power Engineering Test Center (NU PEC), in order to prove the structural reliability by vibrating the test model (of full scale or close to the actual size) in the condition of a destructive earthquake. As for the test models, the following four items were selected out of large components and equipment important to the safety: Reactor Containment Vessel; Primary Coolant Loop or Primary Loop Recirculation System; Reactor Pressure Vessel; and Reactor Core Internals. Here is described a brief of the vibration table, the test method and the results of the tests on PWR Reactor Containment Vessel and BWR Primary Loop Recirculation System (author)

  10. Bayes Analysis and Reliability Implications of Stress-Rupture Testing a Kevlar/Epoxy COPV Using Temperature and Pressure Acceleration

    Science.gov (United States)

    Phoenix, S. Leigh; Kezirian, Michael T.; Murthy, Pappu L. N.

    2009-01-01

    Composite Overwrapped Pressure Vessels (COPVs) that have survived a long service time under pressure generally must be recertified before service is extended. Flight certification is dependent on the reliability analysis to quantify the risk of stress rupture failure in existing flight vessels. Full certification of this reliability model would require a statistically significant number of lifetime tests to be performed and is impractical given the cost and limited flight hardware for certification testing purposes. One approach to confirm the reliability model is to perform a stress rupture test on a flight COPV. Currently, testing of such a Kevlar49 (Dupont)/epoxy COPV is nearing completion. The present paper focuses on a Bayesian statistical approach to analyze the possible failure time results of this test and to assess the implications in choosing between possible model parameter values that in the past have had significant uncertainty. The key uncertain parameters in this case are the actual fiber stress ratio at operating pressure, and the Weibull shape parameter for lifetime; the former has been uncertain due to ambiguities in interpreting the original and a duplicate burst test. The latter has been uncertain due to major differences between COPVs in the database and the actual COPVs in service. Any information obtained that clarifies and eliminates uncertainty in these parameters will have a major effect on the predicted reliability of the service COPVs going forward. The key result is that the longer the vessel survives, the more likely the more optimistic stress ratio model is correct. At the time of writing, the resulting effect on predicted future reliability is dramatic, increasing it by about one "nine," that is, reducing the predicted probability of failure by an order of magnitude. However, testing one vessel does not change the uncertainty on the Weibull shape parameter for lifetime since testing several vessels would be necessary.

  11. Reliability and feasibility of the six minute walk test in subjects with myotonic dystrophy.

    Science.gov (United States)

    Kierkegaard, Marie; Tollbäck, Anna

    2007-12-01

    The objective was to describe test-retest reliability and feasibility of the six minute walk test in adult subjects with myotonic dystrophy type 1. Twelve subjects (28-68 years, mean 44) performed three six minute walk tests on two occasions, one week apart. Relative reliability was high (ICC(2.1)=0.99) and absolute reliability values were low (standard error of measurement 12 m, repeatability 33 m). Feasibility was investigated in a sample of 64 subjects (19-70 years, mean 43). Fifty-two subjects were able to perform two tests on the same day. Subjects with severe proximal weakness had difficulties performing repeated tests. A practice trial followed by a second test on the same day can be recommended for most subjects, and the best test should be used for evaluations. In conclusion, even though the study sample was small, the present study indicates that the six minute walk test is reliable and feasible in subjects with myotonic dystrophy type 1.

  12. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Science.gov (United States)

    Tidstrand, Johan; Horneij, Eva

    2009-01-01

    Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar

  13. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Directory of Open Access Journals (Sweden)

    Tidstrand Johan

    2009-06-01

    Full Text Available Abstract Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs. Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0, for sitting on a Bobath ball good (κ: 0.79 and very good (κ: 0.88 and for the unilateral pelvic lift: good (κ: 0.61 and moderate (κ: 0.47. Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their

  14. Reliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people

    Directory of Open Access Journals (Sweden)

    Boneth M

    2012-05-01

    Full Text Available Objective: to assess the test-retest reliability and level of agreement between measures of the 30 second (30-s Arm Curl and 30-s Chair Stand test in a sample of older adults from Bucaramanga. Materials and methods: a study of evaluation of diagnostic technology was done. Both tests were administered by the same evaluator to 111 adults older than 59 year-old (70,4 ± 7,3, on two occasions, with an interval of time between measures of 4 to 8 days. In the analysis, test-retest reliability was determined using the Intraclass Correlation Coefficient ICC= 2,1 with their confidence interval 95% (CI 95% respective. The agreement level was established by the Bland and Altman method. Results: the test-retest reproducibility of the 30-s Arm Curl test was very good ICC= 0,88 and to the Chair Stand test was good ICC= 0,78. The agreement was very good for both tests of muscle endurance. The CI 95% were between -3,8 and 3,2 stands to 30-s Chair Stand test and between -3,1 and 2,8 curls to 30-s Arm Curl test. Conclusion: the 30-s Arm Curl and 30-s Chair Stand test have good reliability and agreement to assess muscle endurance in older adults functionally independent.

  15. Research Note The reliability of a field test kit for the detection and ...

    African Journals Online (AJOL)

    Research Note The reliability of a field test kit for the detection and the persistence of ... Open Access DOWNLOAD FULL TEXT ... The objectives were to test a field kit for practicality and reliability, to assess the spread of the bacteria among ...

  16. Reliability of the test of gross motor development second edition (TGMD-2) for Kindergarten children in Myanmar.

    Science.gov (United States)

    Aye, Thanda; Oo, Khin Saw; Khin, Myo Thuzar; Kuramoto-Ahuja, Tsugumi; Maruyama, Hitoshi

    2017-10-01

    [Purpose] The purpose of this study was to investigate reliability of the test of gross motor development second edition (TGMD-2) for Kindergarten children in Myanmar. [Subjects and Methods] Fifty healthy Kindergarten children (23 males, 27 females) whose parents/guardians had given written consent were participated. The subjects were explained and demonstrated all 12 gross motor skills of TGMD-2 before the assessment. Each subject individually performed two trials for each gross motor skill and the performance was video recorded. Three raters separately watched the video recordings and rated for inter-rater reliability. The second assessment was done one month later with 25 out of 50 subjects for test-rest reliability. The video recordings of 12 subjects were randomly selected from the first 50 recordings for intra-rater reliability six weeks after the first assessment. The agreement on the locomotor and object control raw scores and the gross motor quotient (GMQ) were calculated. [Results] The findings of all the reliability coefficients for the locomotor and object control raw scores and the GMQ were interpreted as good and excellent reliability. [Conclusion] The results represented that TGMD-2 is a highly reliable and appropriate assessment tool for assessing gross motor skill development of Kindergarten children in Myanmar.

  17. Reliability of a New Lower-Extremity Motor Coordination Test

    Directory of Open Access Journals (Sweden)

    Antosiak-Cyrak Katarzyna

    2015-12-01

    Full Text Available Introduction. Motor coordination is a basic motor ability necessary for daily life, which also allows athletes to win a sports rivalry and patients to assess their recovery progress after therapy and rehabilitation. The aim of the present study was to assess the reliability of a new lower-extremity rate of movements test and testing apparatus.

  18. The validity and reliability of a dynamic neuromuscular stabilization-heel sliding test for core stability.

    Science.gov (United States)

    Cha, Young Joo; Lee, Jae Jin; Kim, Do Hyun; You, Joshua Sung H

    2017-10-23

    Core stabilization plays an important role in the regulation of postural stability. To overcome shortcomings associated with pain and severe core instability during conventional core stabilization tests, we recently developed the dynamic neuromuscular stabilization-based heel sliding (DNS-HS) test. The purpose of this study was to establish the criterion validity and test-retest reliability of the novel DNS-HS test. Twenty young adults with core instability completed both the bilateral straight leg lowering test (BSLLT) and DNS-HS test for the criterion validity study and repeated the DNS-HS test for the test-retest reliability study. Criterion validity was determined by comparing hip joint angle data that were obtained from BSLLT and DNS-HS measures. The test-retest reliability was determined by comparing hip joint angle data. Criterion validity was (ICC2,3) = 0.700 (preliability was (ICC3,3) = 0.953 (pvalidity data demonstrated a good relationship between the gold standard BSLLT and DNS-HS core stability measures. Test-retest reliability data suggests that DNS-HS core stability was a reliable test for core stability. Clinically, the DNS-HS test is useful to objectively quantify core instability and allow early detection and evaluation.

  19. Assessment of Advanced Life Support competence when combining different test methods--reliability and validity

    DEFF Research Database (Denmark)

    Ringsted, C; Lippert, F; Hesselfeldt, R

    2007-01-01

    Cardiac Arrest Simulation Test (CASTest) scenarios for the assessments according to guidelines 2005. AIMS: To analyse the reliability and validity of the individual sub-tests provided by ERC and to find a combination of MCQ and CASTest that provides a reliable and valid single effect measure of ALS...... that possessed high reliability, equality of test sets, and ability to discriminate between the two groups of supposedly different ALS competence. CONCLUSIONS: ERC sub-tests of ALS competence possess sufficient reliability and validity. A combined ALS score with equal weighting of one MCQ and one CASTest can...... competence. METHODS: Two groups of participants were included in this randomised, controlled experimental study: a group of newly graduated doctors, who had not taken the ALS course (N=17) and a group of students, who had passed the ALS course 9 months before the study (N=16). Reliability in terms of inter...

  20. Reliability and convergent validity of the five-step test in people with chronic stroke.

    Science.gov (United States)

    Ng, Shamay S M; Tse, Mimi M Y; Tam, Eric W C; Lai, Cynthia Y Y

    2018-01-10

    (i) To estimate the intra-rater, inter-rater and test-retest reliabilities of the Five-Step Test (FST), as well as the minimum detectable change in FST completion times in people with stroke. (ii) To estimate the convergent validity of the FST with other measures of stroke-specific impairments. (iii) To identify the best cut-off times for distinguishing FST performance in people with stroke from that of healthy older adults. A cross-sectional study. University-based rehabilitation centre. Forty-eight people with stroke and 39 healthy controls. None. The FST, along with (for the stroke survivors only) scores on the Fugl-Meyer Lower Extremity Assessment (FMA-LE), the Berg Balance Scale (BBS), Limits of Stability (LOS) tests, and Activities-specific Balance Confidence (ABC) scale were tested. The FST showed excellent intra-rater (intra-class correlation coefficient; ICC = 0.866-0.905), inter-rater (ICC = 0.998), and test-retest (ICC = 0.838-0.842) reliabilities. A minimum detectable change of 9.16 s was found for the FST in people with stroke. The FST correlated significantly with the FMA-LE, BBS, and LOS results in the forward and sideways directions (r = -0.411 to -0.716, p people with stroke and healthy older adults. The FST is a reliable, easy-to-administer clinical test for assessing stroke survivors' ability to negotiate steps and stairs.

  1. INTERSESSION RELIABILITY OF UPPER EXTREMITY ISOKINETIC PUSH-PULL TESTING.

    Science.gov (United States)

    Riemann, Bryan L; Davis, Sarah E; Huet, Kevin; Davies, George J

    2016-02-01

    Based on the frequency pushing and pulling patterns are used in functional activities, there is a need to establish an objective method of quantifying the muscle performance characteristics associated with these motions, particularly during the later stages of rehabilitation as criteria for discharge. While isokinetic assessment offers an approach to quantifying muscle performance, little is known about closed kinetic chain (CKC) isokinetic testing of the upper extremity (UE). To determine the intersession reliability of isokinetic upper extremity measurement of pushing and pulling peak force and average power at slow (0.24 m/s), medium (0.43 m/s) and fast (0.61 m/s) velocities in healthy young adults. The secondary purpose was to compare pushing and pulling peak force (PF) and average power (AP) between the upper extremity limbs (dominant, non-dominant) across the three velocities. Twenty-four physically active men and women completed a test-retest (>96 hours) protocol in order to establish isokinetic UE CKC reliability of PF and AP during five maximal push and pull repetitions at three velocities. Both limb and speed orders were randomized between subjects. High test-retest relative reliability using intraclass correlation coefficients (ICC2, 1) were revealed for PF (.91-.97) and AP (.85-.95) across velocities, limbs and directions. PF typical error (% coefficient of variation) ranged from 6.1% to 11.3% while AP ranged from 9.9% to 26.7%. PF decreased significantly (p pushing were significantly greater than pulling at all velocities, however the push-pull differences in PF became less as velocity increased. There were no significant differences identified between the dominant and nondominant limbs. Isokinetically derived UE CKC push-pull PF and AP are reliable measures. The lack of limb differences in healthy normal participants suggests that clinicians can consider bilateral comparisons when interpreting test performance. The increase in pushing PF and

  2. The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain

    Science.gov (United States)

    2013-01-01

    Background This study investigates the reliability of muscle performance tests using cost- and time-effective methods similar to those used in clinical practice. When conducting reliability studies, great effort goes into standardising test procedures to facilitate a stable outcome. Therefore, several test trials are often performed. However, when muscle performance tests are applied in the clinical setting, clinicians often only conduct a muscle performance test once as repeated testing may produce fatigue and pain, thus variation in test results. We aimed to investigate whether cervical muscle performance tests, which have shown promising psychometric properties, would remain reliable when examined under conditions similar to those of daily clinical practice. Methods The intra-rater (between-day) and inter-rater (within-day) reliability was assessed for five cervical muscle performance tests in patients with (n = 33) and without neck pain (n = 30). The five tests were joint position error, the cranio-cervical flexion test, the neck flexor muscle endurance test performed in supine and in a 45°-upright position and a new neck extensor test. Results Intra-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.48-0.82), the cranio-cervical flexion test (ICC ≥ 0.69), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.68) and in a 45°-upright position (ICC ≥ 0.41) with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement (ICC = 0.14-0.41). Likewise, inter-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.51-0.75), the cranio-cervical flexion test (ICC ≥ 0.85), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.70) and in a 45°-upright position (ICC ≥ 0.56). However, only slight to fair agreement was found for the neck extensor test (ICC

  3. Long term test-retest reliability of Oswestry Disability Index in male office workers.

    Science.gov (United States)

    Irmak, Rafet; Baltaci, Gul; Ergun, Nevin

    2015-01-01

    The Oswestry Disability Index (ODI) is one of the most common condition specific outcome measures used in the management of spinal disorders. But there is insufficient study on healthy populations and long term test-retest reliability. This is important because healthy populations are often used for control groups in low back pain interventions, and knowing the reliability of the controls affects the interpretation of the findings of these studies. The purpose of this study is to determine the long term test-retest reliability of ODI in office workers. Participants who have no chronic low back pain history were included in study. Subjects were assessed by the Turkish-ODI 2.0 (e-forms) on 1st, 2nd, 4th, 8th, 15th, 30th days to determine the stability of ODI scores over time. The study began with 58 (12 female, 46 male) participants. 36 (3 female, 33 male) participated for the full 30 days. Kolmogorov-Smirnov and Friedman tests were used. Test-retest reliability was evaluated by using nonparametric statistics. All tests were done by using SPSS-11. There was no statistically significant difference among the median scores of each day. (χ= 6.482, p >  0.05). The difference between median score of the days with 1st day was neither statistically nor clinically significant. ODI has long term test re-test reliability in healthy subjects over a 1 month time interval.

  4. Exploration of reliability databases and comparison of former IFMIF's results

    International Nuclear Information System (INIS)

    Tapia, Carlos; Dies, Javier; Abal, Javier; Ibarra, Angel; Arroyo, Jose M.

    2011-01-01

    There is an uncertainty issue about the applicability of industrial databases to new designs, such as the International Fusion Materials Irradiation Facility (IFMIF), as they usually contain elements for which no historical statistics exist. The exploration of common components reliability data in Accelerator Driven Systems (ADS) and Liquid Metal Technologies (LMT) frameworks is the milestone to analyze the data used in IFMIF reliability's reports and for future studies. The comparison between the reliability accelerator results given in the former IFMIF's reports and the databases explored has been made by means of a new accelerator Reliability, Availability, Maintainability (RAM) analysis. The reliability database used in this analysis is traceable.

  5. Reliability, construct and discriminative validity of clinical testing in subjects with and without chronic neck pain

    DEFF Research Database (Denmark)

    Jørgensen, René; Ris Hansen, Inge; Falla, Deborah

    2014-01-01

    -retest reliability in people with and without chronic neck pain. Moreover, construct and between-group discriminative validity of the tests were examined. METHODS: Twenty-one participants with chronic neck pain and 21 asymptomatic participants were included. Intra- and inter-reliability were evaluated for the Cranio-Cervical...... Flexion Test (CCFT), Range of Movement (ROM), Joint Position Error (JPE), Gaze Stability (GS), Smooth Pursuit Neck Torsion Test (SPNTT), and neuromuscular control of the Deep Cervical Extensors (DCE). Test-retest reliability was assessed for Postural Control (SWAY) and Pressure Pain Threshold (PPT) over......BACKGROUND: The reliability of clinical tests for the cervical spine has not been adequately evaluated. Six cervical clinical tests, which are low cost and easy to perform in clinical settings, were tested for intra- and inter-examiner reliability, and two performance tests were assessed for test...

  6. Frontiers of reliability

    CERN Document Server

    Basu, Asit P; Basu, Sujit K

    1998-01-01

    This volume presents recent results in reliability theory by leading experts in the world. It will prove valuable for researchers, and users of reliability theory. It consists of refereed invited papers on a broad spectrum of topics in reliability. The subjects covered include Bayesian reliability, Bayesian reliability modeling, confounding in a series system, DF tests, Edgeworth approximation to reliability, estimation under random censoring, fault tree reduction for reliability, inference about changes in hazard rates, information theory and reliability, mixture experiment, mixture of Weibul

  7. Results from the LHC Beam Dump Reliability Run

    CERN Document Server

    Uythoven, J; Carlier, E; Castronuovo, F; Ducimetière, L; Gallet, E; Goddard, B; Magnin, N; Verhagen, H

    2008-01-01

    The LHC Beam Dumping System is one of the vital elements of the LHC Machine Protection System and has to operate reliably every time a beam dump request is made. Detailed dependability calculations have been made, resulting in expected rates for the different system failure modes. A 'reliability run' of the whole system, installed in its final configuration in the LHC, has been made to discover infant mortality problems and to compare the occurrence of the measured failure modes with their calculations.

  8. Evaluating test-retest reliability in patient-reported outcome measures for older people: A systematic review.

    Science.gov (United States)

    Park, Myung Sook; Kang, Kyung Ja; Jang, Sun Joo; Lee, Joo Yun; Chang, Sun Ju

    2018-03-01

    the studies that report the results of test-retest reliability. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Long-Term Reliability of SiGe/Si HBTs From Accelerated Lifetime Testing

    Science.gov (United States)

    Bhattacharya, Pallab

    2001-01-01

    Accelerated lifetime tests were performed on double-mesa structure Si(0.7)Ge(0.3)/Si npn heterojunction bipolar transistors, grown by molecular beam epitaxy, in the temperature range of 175 C-275 C. The transistors (with 5x20 sq micron emitter area) have DC current gains approx. 40-50 and f(sub T) and f(sub max) of up to 22 GHz and 25 GHz, respectively. It is found that a gradual degradation in these devices is caused by the recombination enhanced impurity diffusion (REID) of boron atoms from the p-type base region and the associated formation of parasitic energy barriers to electron transport from the emitter to collector layers. This REED has been quantitatively modeled and explained, to the first order of approximation, and the agreement with the measured data is good. The mean time to failure (MTTF) of these devices at room temperature under 1.35 x 10(exp 4) A/sq cm current density operation is estimated from the extrapolation of the Arrhenius plots of device lifetime versus reciprocal temperature. The results of the reliability tests offer valuable feedback for SiGe heterostructure design in order to improve the long-term reliability of the devices and circuits made with them. Hot electron induced degradation of the base-emitter junction was also observed during the accelerated lifetime testing. In order to improve the HBT reliability endangered by the hot electrons, deuterium sintered techniques have been proposed. The preliminary results from this study show that a deuterium-sintered HBT is, indeed, more resistant to hot-electron induced base-emitter junction degradation.

  10. Evaluating the test-retest reliability of symptom indices associated with the ImPACT post-concussion symptom scale (PCSS).

    Science.gov (United States)

    Merritt, Victoria C; Bradson, Megan L; Meyer, Jessica E; Arnett, Peter A

    2018-05-01

    The Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) is a commonly used tool in sports concussion assessment. While test-retest reliabilities have been established for the ImPACT cognitive composites, few studies have evaluated the psychometric properties of the ImPACT's Post-Concussion Symptom Scale (PCSS). The purpose of this study was to establish the test-retest reliability of symptom indices associated with the PCSS. Participants included 38 undergraduate students (50.0% male) who underwent neuropsychological testing as part of their participation in their psychology department's research subject pool. The majority of the participants were Caucasian (94.7%) and had no history of concussion (73.7%). All participants completed the ImPACT at two time points, approximately 6 weeks apart. The PCSS was the main outcome measure, and eight symptom indices were calculated (a total symptom score, three symptom summary indices, and four symptom clusters). Pearson correlations (r) and intraclass correlation coefficients (ICCs) were computed as measures of test-retest reliability. Overall, reliabilities ranged from low to high (r = .44 to .80; ICC = .44 to .77). The cognitive symptom cluster exhibited the highest test-retest reliability (r = .80, ICC = .77), followed by the positive symptom total (PST) index, an indicator of the total number of symptoms endorsed (r = .71, ICC = .69). In contrast, the commonly used total symptom score showed lower test-retest reliability (r = .67, ICC = .62). Paired-samples t tests revealed no significant differences between test and retest for any of the symptom variables (all p > .01). Finally, reliable change indices (RCI) were computed to determine whether differences observed between test and retest represented clinically significant change. RCI values were provided for each symptom index at the 80%, 90%, and 95% confidence intervals. These results suggest that evaluating additional symptom

  11. Development of a Saudi Food Frequency Questionnaire and testing its reliability and validity.

    Science.gov (United States)

    Gosadi, Ibrahim M; Alatar, Abdullah A; Otayf, Mojahed M; AlJahani, Dhaherah M; Ghabbani, Hisham M; AlRajban, Waleed A; Alrsheed, Abdullah M; Al-Nasser, Khalid A

    2017-06-01

    To create a food frequency questionnaire specifically designed to capture the dietary habits of Saudis and test its validity and reliability. Methods: This investigation is a longitudinal, test-retest study conducted in King Saud University, Riyadh, Kingdom of Saudi Arabia between December 2015 and March 2016. A list of 140 food items was included in the questionnaire where a closed-ended and open-ended approach was used. Regarding past   year food frequency consumption and 24 hours dietary recall, body weight and height were collected. Internal consistency, test-retest reliability, completeness of the food list, and criterion validity were assessed. Results: One-hundred and thirty eight participants were interviewed to complete the 24 hours dietary recall and the constructed questionnaire. Approximately 85% of the food items reported in the dietary recall were covered in the food frequency questionnaire. The association of body mass index with meats (regression coefficients: 2.28) and dairy products consumption frequency was statistically significant (regression coefficients: 2.31). A high overall reproducibility rate of the questionnaire was detected (Pearsons' correlation coefficient: 0.78 p less than 0.001).  Conclusion: The developed questionnaire has a high reliability and reasonable validity, and suitable for use in nutritional epidemiological investigations in Saudi Arabia.

  12. Accuracy and reliability of Tzanck test compared to histopathology for diagnosis of basal cell carcinoma

    Directory of Open Access Journals (Sweden)

    Vivek Kumar Dey

    2015-01-01

    Full Text Available Background: Histopathology is considered the gold standard for diagnosis of basal cell carcinoma (BCC but is time consuming and needs expertise to make a correct diagnosis. On the other hand, Tzanck test is a simple, easy, inexpensive and rapid test which uses exfoliative cytology to make a diagnosis. Objective: To compare the results of Tzanck test with histopathology in the diagnosis of BCC and to evaluate the diagnostic reliability and accuracy of Tzanck test in BCC. Materials and Method: Twenty-six patients with clinical suspicion of BCC were recruited. Samples for Tzanck test and histopathology were taken and diagnoses made independently. Results of Tzanck test were compared with histopathology. Results: Twenty-three cases were histopathologically proved to be BCC. Tzanck test correlated in 12 cases of BCC and could exclude all three non-BCC lesions. In 11 cases it failed to diagnose BCC. The sensitivity and specificity of Tzanck test were 52.2% and 100%, respectively, and positive and negative predictive values were 100% and 21.4%. Conclusion: Tzanck test can be recommended for initial, rapid evaluation of a clinically diagnosed case of BCC. Under experienced hands, it reliably confirms BCC. The limitation is low negative predictive value. Since it does not give information about subtypes of BCC which is of great value in therapeutic planning, histopathological confirmation is mandatory.

  13. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  14. The Ostomy Adjustment Scale: translation into Norwegian language with validation and reliability testing.

    Science.gov (United States)

    Indrebø, Kirsten Lerum; Andersen, John Roger; Natvig, Gerd Karin

    2014-01-01

    The purpose of this study was to adapt the Ostomy Adjustment Scale to a Norwegian version and to assess its construct validity and 2 components of its reliability (internal consistency and test-retest reliability). One hundred fifty-eight of 217 patients (73%) with a colostomy, ileostomy, or urostomy participated in the study. Slightly more than half (56%) were men. Their mean age was 64 years (range, 26-91 years). All respondents had undergone ostomy surgery at least 3 months before participation in the study. The Ostomy Adjustment Scale was translated into Norwegian according to standard procedures for forward and backward translation. The questionnaire was sent to the participants via regular post. The Cronbach alpha and test-retest were computed to assess reliability. Construct validity was evaluated via correlations between each item and score sums; correlations were used to analyze relationships between the Ostomy Adjustment Scale and the 36-item Short Form Health Survey, the Quality of Life Scale, the Hospital Anxiety & Depression Scale, and the General Self-Efficacy Scale. The Cronbach alpha was 0.93, and test-retest reliability r was 0.69. The average correlation quotient item to sum score was 0.49 (range, 0.31-0.73). Results showed moderate negative correlations between the Ostomy Adjustment Scale and the Hospital Anxiety and Depression Scale (-0.37 and -0.40), and moderate positive correlations between the Ostomy Adjustment Scale and the 36-item Short Form Health Survey, the Quality of Life Scale, and the General Self-Efficacy Scale (0.30-0.45) with the exception of the pain domain in the Short Form 36 (0.28). Regression analysis showed linear associations between the Ostomy Adjustment Scale and sociodemographic and clinical variables with the exception of education. The Norwegian language version of the Ostomy Adjustment Scale was found to possess construct validity, along with internal consistency and test-retest reliability. The instrument is

  15. Feasibility and test-retest reliability of measuring lower‑limb strength in young children with cerebral palsy.

    Science.gov (United States)

    Van Vulpen, L F; De Groot, S; Becher, J G; De Wolf, G S; Dallmeijer, A J

    2013-12-01

    Quantifying leg muscle strength in young children with cerebral palsy (CP) is essential for identifying muscle groups for treatment and for monitoring progress. To study the feasibility, intratester reliability and the optimal test design (number of test occasions and repetitions) of measuring lower-limb strength with handheld dynamometry (HHD) and dynamic ankle plantar flexor strength with the standing heel-rise (SH) test in 3-10 year aged children with CP. Test-retest design. Rehabilitation centre, special needs school for children with disabilities, and university medical centre. Knee extensor, hip abductor and calf muscle strength was assessed in 20 ambulatory children with spastic CP (3-5 years [N.=10] and 6-10 years [N.=10]) on two test occasions. Intraclass correlation coefficients (ICC) and Smallest Detectable Differences (SDD) were calculated to determine the optimal test design for detecting changes in strength. All isometric strength tests had acceptable SDDs (9-30%), when taking the mean values of 2-3 test occasions (separate days) and 2-3 repetitions. The one-leg SH test had large SDDs (40-128% for younger group, 23-48% for older group). Isometric strength (improvements) can only be measured reliably with HHD in young children with CP when the average values over at least 2 test occasions are taken. Reliability of the SH test is not sufficient for measuring individual changes in dynamic muscle strength in the younger children. Results of this study can be used to determine the optimal number of test occasions and repetitions for reliable HHD measurements depending on expected changes, muscle group and age in 3-10 year old children with CP.

  16. Reliability performance testing of totally encapsulating chemical protective suits

    International Nuclear Information System (INIS)

    Johnson, J.S.; Swearengen, P.M.

    1991-01-01

    The need to assure a high degree of reliability for totally encapsulating chemical protective (TECP) suits has been recognized by Lawrence Livermore National Laboratory's (LLNL) Hazards Control Department for some time. The following four tests were proposed as necessary to provide complete evaluation of TECP suit performance: 1. Quantitative leak test (ASTM draft), 2. Worst-case chemical exposure test (conceptual), 3. Pressure leak-rate test (complete, ASTM F1057-87), and 4. Chemical leak-rate test (ASTM draft). This paper reports on these tests which should be applied to measuring TECP suit performance in two stages: design qualification tests and field use tests. Test 1, 2, and 3 are used as design qualification tests, and tests 3 and 4 are used as field use tests

  17. Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study

    Directory of Open Access Journals (Sweden)

    Koblbauer Ian FH

    2011-10-01

    Full Text Available Abstract Background Patients undergoing total knee arthroplasty (TKA often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable measurements should be used. This study aimed to determine the inter- and intrarater reliability of hand-held dynamometry (HHD in measuring isometric knee strength in patients awaiting TKA. Methods To determine interrater reliability, 32 patients (81.3% female were assessed by two examiners. Patients were assessed consecutively by both examiners on the same individual test dates. To determine intrarater reliability, a subgroup (n = 13 was again assessed by the examiners within four weeks of the initial testing procedure. Maximal isometric knee flexor and extensor strength were tested using a modified Citec hand-held dynamometer. Both the affected and unaffected knee were tested. Reliability was assessed using the Intraclass Correlation Coefficient (ICC. In addition, the Standard Error of Measurement (SEM and the Smallest Detectable Difference (SDD were used to determine reliability. Results In both the affected and unaffected knee, the inter- and intrarater reliability were good for knee flexors (ICC range 0.76-0.94 and excellent for knee extensors (ICC range 0.92-0.97. However, measurement error was high, displaying SDD ranges between 21.7% and 36.2% for interrater reliability and between 19.0% and 57.5% for intrarater reliability. Overall, measurement error was higher for the knee flexors than for the knee extensors. Conclusions Modified HHD appears to be a reliable strength measure, producing good to excellent ICC values for both inter- and intrarater reliability in a group of TKA patients. High SEM and SDD values, however, indicate high measurement error for individual measures. This study demonstrates that a modified HHD is appropriate to

  18. Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG Test in Patients with Parkinson's Disease.

    Directory of Open Access Journals (Sweden)

    Rob C van Lummel

    Full Text Available The "Timed Up and Go" (TUG is a widely used measure of physical functioning in older people and in neurological populations, including Parkinson's Disease. When using an inertial sensor measurement system (instrumented TUG [iTUG], the individual components of the iTUG and the trunk kinematics can be measured separately, which may provide relevant additional information.The aim of this study was to determine intra-rater, inter-rater and test-retest reliability of the iTUG in patients with Parkinson's Disease.Twenty eight PD patients, aged 50 years or older, were included. For the iTUG the DynaPort Hybrid (McRoberts, The Hague, The Netherlands was worn at the lower back. The device measured acceleration and angular velocity in three directions at a rate of 100 samples/s. Patients performed the iTUG five times on two consecutive days. Repeated measurements by the same rater on the same day were used to calculate intra-rater reliability. Repeated measurements by different raters on the same day were used to calculate intra-rater and inter-rater reliability. Repeated measurements by the same rater on different days were used to calculate test-retest reliability.Nineteen ICC values (15% were ≥ 0.9 which is considered as excellent reliability. Sixty four ICC values (49% were ≥ 0.70 and < 0.90 which is considered as good reliability. Thirty one ICC values (24% were ≥ 0.50 and < 0.70, indicating moderate reliability. Sixteen ICC values (12% were ≥ 0.30 and < 0.50 indicating poor reliability. Two ICT values (2% were < 0.30 indicating very poor reliability.In conclusion, in patients with Parkinson's disease the intra-rater, inter-rater, and test-retest reliability of the individual components of the instrumented TUG (iTUG was excellent to good for total duration and for turning durations, and good to low for the sub durations and for the kinematics of the SiSt and StSi. The results of this fully automated analysis of instrumented TUG movements

  19. Intra-tester Reliability and Construct Validity of a Hip Abductor Eccentric Strength Test.

    Science.gov (United States)

    Brindle, Richard A; Ebaugh, D David; Milner, Clare E

    2017-11-15

    Side-lying hip abductor strength tests are commonly used to evaluate muscle strength. In a 'break' test the tester applies sufficient force to lower the limb to the table while the patient resists. The peak force is postulated to occur while the leg is lowering, thus representing the participant's eccentric muscle strength. However, it is unclear whether peak force occurs before or after the leg begins to lower. To determine intra-rater reliability and construct validity of a hip abductor eccentric strength test. Intra-rater reliability and construct validity study. Twenty healthy adults (26 ±6 years; 1.66 ±0.06 m; 62.2 ±8.0 kg) made two visits to the laboratory at least one week apart. During the hip abductor eccentric strength test, a hand-held dynamometer recorded peak force and time to peak force and limb position was recorded via a motion capture system. Intra-rater reliability was determined using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable difference (MDD). Construct validity was assessed by determining if peak force occurred after the start of the lowering phase using a one-sample t-test. The hip abductor eccentric strength test had substantial intra-rater reliability (ICC( 3,3 ) = 0.88; 95% confidence interval: 0.65-0.95), SEM of 0.9%BWh, and a MDD of 2.5%BWh. Construct validity was established as peak force occurred 2.1s (±0.6s; range 0.7s to 3.7s) after the start of the lowering phase of the test (p ≤ 0.001). The hip abductor eccentric strength test is a valid and reliable measure of eccentric muscle strength. This test may be used clinically to assess changes in eccentric muscle strength over time.

  20. Test-retest reliability of the Battery for the Assessment of Auditory Sensorimotor and Timing Abilities (BAASTA).

    Science.gov (United States)

    Bégel, Valentin; Verga, Laura; Benoit, Charles-Etienne; Kotz, Sonja A; Bella, Simone Dalla

    2018-04-27

    Perceptual and sensorimotor timing skills can be comprehensively assessed with the Battery for the Assessment of Auditory Sensorimotor and Timing Abilities (BAASTA). The battery has been used for testing rhythmic skills in healthy adults and patient populations (e.g., with Parkinson disease), showing sensitivity to timing and rhythm deficits. Here we assessed the test-retest reliability of the BAASTA in 20 healthy adults. Participants were tested twice with the BAASTA, implemented on a tablet interface, with a 2-week interval. They completed 4 perceptual tasks, namely, duration discrimination, anisochrony detection with tones and music, and the Beat Alignment Test (BAT). Moreover, they completed motor tasks via finger tapping, including unpaced and paced tapping with tones and music, synchronization-continuation, and adaptive tapping to a sequence with a tempo change. Despite high variability among individuals, the results showed stable test-retest reliability in most tasks. A slight but significant improvement from test to retest was found in tapping with music, which may reflect a learning effect. In general, the BAASTA was found a reliable tool for evaluating timing and rhythm skills. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  1. Systems reliability Benchmark exercise part 1-Description and results

    International Nuclear Information System (INIS)

    Amendola, A.

    1986-01-01

    The report describes aims, rules and results of the Systems Reliability Benchmark Exercise, which has been performed in order to assess methods and procedures for reliability analysis of complex systems and involved a large number of European organizations active in NPP safety evaluation. The exercise included both qualitative and quantitative methods and was structured in such a way that separation of the effects of uncertainties in modelling and in data on the overall spread was made possible. Part I describes the way in which RBE has been performed, its main results and conclusions

  2. Perform qualify reliability-power tests by shooting common mistakes: practical problems and standard answers per Telcordia/Bellcore requests

    Science.gov (United States)

    Yu, Zheng

    2002-08-01

    Facing the new demands of the optical fiber communications market, almost all the performance and reliability of optical network system are dependent on the qualification of the fiber optics components. So, how to comply with the system requirements, the Telcordia / Bellcore reliability and high-power testing has become the key issue for the fiber optics components manufacturers. The qualification of Telcordia / Bellcore reliability or high-power testing is a crucial issue for the manufacturers. It is relating to who is the outstanding one in the intense competition market. These testing also need maintenances and optimizations. Now, work on the reliability and high-power testing have become the new demands in the market. The way is needed to get the 'Triple-Win' goal expected by the component-makers, the reliability-testers and the system-users. To those who are meeting practical problems for the testing, there are following seven topics that deal with how to shoot the common mistakes to perform qualify reliability and high-power testing: ¸ Qualification maintenance requirements for the reliability testing ¸ Lots control for preparing the reliability testing ¸ Sampling select per the reliability testing ¸ Interim measurements during the reliability testing ¸ Basic referencing factors relating to the high-power testing ¸ Necessity of re-qualification testing for the changing of producing ¸ Understanding the similarity for product family by the definitions

  3. A Comparison of the Approaches of Generalizability Theory and Item Response Theory in Estimating the Reliability of Test Scores for Testlet-Composed Tests

    Science.gov (United States)

    Lee, Guemin; Park, In-Yong

    2012-01-01

    Previous assessments of the reliability of test scores for testlet-composed tests have indicated that item-based estimation methods overestimate reliability. This study was designed to address issues related to the extent to which item-based estimation methods overestimate the reliability of test scores composed of testlets and to compare several…

  4. Test-retest reliability of trunk accelerometric gait analysis

    DEFF Research Database (Denmark)

    Henriksen, Marius; Lund, Hans; Moe-Nilssen, R

    2004-01-01

    The purpose of this study was to determine the test-retest reliability of a trunk accelerometric gait analysis in healthy subjects. Accelerations were measured during walking using a triaxial accelerometer mounted on the lumbar spine of the subjects. Six men and 14 women (mean age 35.2; range 18...... a definite potential in clinical gait analysis....

  5. Test of Creative Imagination: Validity and Reliability Study

    Science.gov (United States)

    Gundogan, Aysun; Ari, Meziyet; Gonen, Mubeccel

    2013-01-01

    The purpose of this study was to investigate validity and reliability of the test of creative imagination. This study was conducted with the participation of 1000 children, aged between 9-14 and were studying in six primary schools in the city center of Denizli Province, chosen by cluster ratio sampling. In the study, it was revealed that the…

  6. Reliability Of Kraus-Weber Exercise Test As An Evaluation Tool In ...

    African Journals Online (AJOL)

    Reliability Of Kraus-Weber Exercise Test As An Evaluation Tool In Low Back ... strength and flexibility of the back, abdominal, psoas and hamstring muscles. ... Keywords: Kraus-Weber test, low back pain, muscle flexibility, muscle strength.

  7. Reliability and sensitivity to change of the timed standing balance test in children with down syndrome

    Directory of Open Access Journals (Sweden)

    Vencita Priyanka Aranha

    2016-01-01

    Full Text Available Objective: To estimate the reliability and sensitivity to change of the timed standing balance test in children with Down syndrome (DS. Methods: It was a nonblinded, comparison study with a convenience sample of subjects consisting of children with DS (n = 9 aged 8–17 years. The main outcome measure was standing balance which was assessed using timed standing balance test, the time required to maintain in four conditions, eyes open static, eyes closed static, eyes open dynamic, and eyes closed dynamic. Results: Relative reliability was excellent for all four conditions with an Interclass Correlation Coefficient (ICC ranging from 0.91 to 0.93. The variation between repeated measurements for each condition was minimal with standard error of measurement (SEM of 0.21–0.59 s, suggestive of excellent absolute reliability. The sensitivity to change as measured by smallest real change (SRC was 1.27 s for eyes open static, 1.63 s for eyes closed static, 0.58 s for eyes open dynamic, and 0.61 s for eyes closed static. Conclusions: Timed standing balance test is an easy to administer test and sensitive to change with strong absolute and relative reliabilities, an important first step in establishing its utility as a clinical balance measure in children with DS.

  8. Reliability of wind turbine blades: An overview of materials testing

    DEFF Research Database (Denmark)

    Holmes, John W.; Sørensen, Bent F.; Brøndsted, Povl

    2007-01-01

    an understanding of how damage develops in composite structures, composite materials and adhesives. Designing reliable wind turbine blades also requires the further development of laboratory scale and full scale test methods to evaluate the structural response and durability of new materials under various loading......The structural reliability of wind turbine components can have a profound impact on both the profitability and reputation of a wind turbine manufacturer or supplier of wind turbine components. The issue of reliability is of critical concern when large wind farm co-operatives are considered......, and when wind turbines are located in remote regions where the cost of inspections and repairs can be very high. From a structural viewpoint, wind turbine blades are subjected to very complex loading histories with coupled deformation modes. The long-term reliability of wind turbine blades requires...

  9. MIDAS and HIT-6 French translation: reliability and correlation between tests.

    Science.gov (United States)

    Magnoux, E; Freeman, M A; Zlotnik, G

    2008-01-01

    The aim was to evaluate the test-retest reliability of the French translation of the Migraine Disability Assessment (MIDAS) and Headache Impact Test (HIT)-6 questionnaires as applied to episodic and chronic headaches and to assess the correlation between these two questionnaires. The MIDAS and HIT-6 questionnaires, which assess the degree of migraine-related functional disability, are widely used in headache treatment clinics. The French translation has not been checked for test-retest reliability. MIDAS involves recall, over the previous 3 months, of the number of days with functional disability with regard to work and to home and social life. HIT-6 involves a more subjective and general assessment of headache-related disability over the previous 4 weeks. We expect that there may be greater impact recall bias for chronic headaches than for episodic headaches and considered it important to be able to determine if the reliability of these questionnaires is equally good for these two patient populations. Given that both questionnaires have the same objective, that of assessing headache impact, it was thought useful to determine if their results might show a correlation and if they could thus be used interchangeably. The study was approved by an external ethics committee. The subjects were patients who regularly visit the Clinique de la Migraine de Montréal, which specializes in the treatment of headaches. The MIDAS and HIT-6 questionnaires were completed by the patients during their regular visit. Twelve days later, the same questionnaires were mailed with a prepaid return envelope. Sixty-five patients were required in both the episodic and chronic headache groups, assuming an 80% questionnaire return rate. One hundred and eighty-five patients were enrolled, and 143 completed the study, 75 with episodic headaches and 68 with chronic headaches. The questionnaire return rate was 78.9%. On average, questionnaires were completed a second time 21 days after the first

  10. Test-retest reliability of sensor-based sit-to-stand measures in young and older adults.

    Science.gov (United States)

    Regterschot, G Ruben H; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and Five-Times-Sit-to-Stand Test (FTSST) in older adults. Ten healthy young female adults (20-23 years) and 31 older adults (21 females; 73-94 years) participated in two assessment sessions separated by 3-8 days. Vertical peak power was assessed during three (young adults) and five (older adults) normal and fast STS trials with a hybrid motion sensor worn on the hip. Older adults also performed the FTSST and TUGT. The average sensor-based STS peak power of the normal STS trials and the average sensor-based STS peak power of the fast STS trials showed excellent test-retest reliability in young adults (intra-class correlation (ICC)≥0.90; zero in 95% confidence interval of mean difference between test and retest (95%CI of D); standard error of measurement (SEM)≤6.7% of mean peak power) and older adults (ICC≥0.91; zero in 95%CI of D; SEM≤9.9%). Test-retest reliability of sensor-based STS peak power and TUGT (ICC=0.98; zero in 95%CI of D; SEM=8.5%) was comparable in older adults, test-retest reliability of the FTSST was lower (ICC=0.73; zero outside 95%CI of D; SEM=14.4%). Sensor-based STS peak power demonstrated excellent test-retest reliability and may therefore be useful for clinical assessment of functional status and fall risk. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. The reliability of physical examination tests for the diagnosis of anterior cruciate ligament rupture--A systematic review.

    Science.gov (United States)

    Lange, Toni; Freiberg, Alice; Dröge, Patrik; Lützner, Jörg; Schmitt, Jochen; Kopkow, Christian

    2015-06-01

    Systematic literature review. Despite their frequent application in routine care, a systematic review on the reliability of clinical examination tests to evaluate the integrity of the ACL is missing. To summarize and evaluate intra- and interrater reliability research on physical examination tests used for the diagnosis of ACL tears. A comprehensive systematic literature search was conducted in MEDLINE, EMBASE and AMED until May 30th 2013. Studies were included if they assessed the intra- and/or interrater reliability of physical examination tests for the integrity of the ACL. Methodological quality was evaluated with the Quality Appraisal of Reliability Studies (QAREL) tool by two independent reviewers. 110 hits were achieved of which seven articles finally met the inclusion criteria. These studies examined the reliability of four physical examination tests. Intrarater reliability was assessed in three studies and ranged from fair to almost perfect (Cohen's k = 0.22-1.00). Interrater reliability was assessed in all included studies and ranged from slight to almost perfect (Cohen's k = 0.02-0.81). The Lachman test is the physical tests with the highest intrarater reliability (Cohen's k = 1.00), the Lachman test performed in prone position the test with the highest interrater reliability (Cohen's k = 0.81). Included studies were partly of low methodological quality. A meta-analysis could not be performed due to the heterogeneity in study populations, reliability measures and methodological quality of included studies. Systematic investigations on the reliability of physical examination tests to assess the integrity of the ACL are scarce and of varying methodological quality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.

    Science.gov (United States)

    Medina-Mirapeix, Francesc; Vivo-Fernández, Iván; López-Cañizares, Juan; García-Vidal, José A; Benítez-Martínez, Josep Carles; Del Baño-Aledo, María Elena

    2018-01-01

    The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, ptest-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Reliability of fitness tests using methods and time periods common in sport and occupational management.

    Science.gov (United States)

    Burnstein, Bryan D; Steele, Russell J; Shrier, Ian

    2011-01-01

    Fitness testing is used frequently in many areas of physical activity, but the reliability of these measurements under real-world, practical conditions is unknown. To evaluate the reliability of specific fitness tests using the methods and time periods used in the context of real-world sport and occupational management. Cohort study. Eighteen different Cirque du Soleil shows. Cirque du Soleil physical performers who completed 4 consecutive tests (6-month intervals) and were free of injury or illness at each session (n = 238 of 701 physical performers). Performers completed 6 fitness tests on each assessment date: dynamic balance, Harvard step test, handgrip, vertical jump, pull-ups, and 60-second jump test. We calculated the intraclass coefficient (ICC) and limits of agreement between baseline and each time point and the ICC over all 4 time points combined. Reliability was acceptable (ICC > 0.6) over an 18-month time period for all pairwise comparisons and all time points together for the handgrip, vertical jump, and pull-up assessments. The Harvard step test and 60-second jump test had poor reliability (ICC < 0.6) between baseline and other time points. When we excluded the baseline data and calculated the ICC for 6-month, 12-month, and 18-month time points, both the Harvard step test and 60-second jump test demonstrated acceptable reliability. Dynamic balance was unreliable in all contexts. Limit-of-agreement analysis demonstrated considerable intraindividual variability for some tests and a learning effect by administrators on others. Five of the 6 tests in this battery had acceptable reliability over an 18-month time frame, but the values for certain individuals may vary considerably from time to time for some tests. Specific tests may require a learning period for administrators.

  14. The push-off test: development of a simple, reliable test of upper extremity weight-bearing capability.

    Science.gov (United States)

    Vincent, Joshua I; MacDermid, Joy C; Michlovitz, Susan L; Rafuse, Richard; Wells-Rowsell, Christina; Wong, Owen; Bisbee, Leslie

    2014-01-01

    Longitudinal clinical measurement study. The push-off test (POT) is a novel and simple measure of upper extremity weight-bearing that can be measured with a grip dynamometer. There are no published studies on the validity and reliability of the POT. The relationship between upper extremity self-report activity/participation and impairment measures remain an unexplored realm. The primary purpose of this study is to estimate the intra and inter-rater reliability and construct validity of the POT. The secondary purpose is to estimate the relationship between upper extremity self-report activity/participation questionnaires and impairment measures. A convenience sample of 22 patients with wrist or elbow injuries were tested for POT, wrist/elbow range of motion (ROM), isometric wrist extension strength (WES) and grip strength; and completed two self-report activity/participation questionnaires: Disability of the Arm, Shoulder and the Hand (DASH) and Work Limitations Questionnaire (WLQ-26). POT's inter and intra-rater reliability and construct validity was tested. Pearson's correlations were run between the impairment measures and self-report questionnaires to look into the relationship amongst them. The POT demonstrated high inter-rater reliability (ICC affected = 0.97; 95% C.I. 0.93-0.99; ICC unaffected = 0.85; 95% C.I. 0.68-0.94) and intra-rater reliability (ICC affected = 0.96; 95% C.I. 0.92-0.97; ICC unaffected = 0.92; 95% C.I. 0.85-0.97). The POT was correlated moderately with the DASH (r = -0.47; p = 0.03). While examining the relationship between upper extremity self-reported activity/participation questionnaires and impairment measures the strongest correlation was between the DASH and the POT (r = -0.47; p = 0.03) and none of the correlations with the other physical impairment measures reached significance. At-work disability demonstrated insignificant correlations with physical impairments. The POT test provides a reliable and easily

  15. Photovoltaic module reliability improvement through application testing and failure analysis

    Science.gov (United States)

    Dumas, L. N.; Shumka, A.

    1982-01-01

    During the first four years of the U.S. Department of Energy (DOE) National Photovoltatic Program, the Jet Propulsion Laboratory Low-Cost Solar Array (LSA) Project purchased about 400 kW of photovoltaic modules for test and experiments. In order to identify, report, and analyze test and operational problems with the Block Procurement modules, a problem/failure reporting and analysis system was implemented by the LSA Project with the main purpose of providing manufacturers with feedback from test and field experience needed for the improvement of product performance and reliability. A description of the more significant types of failures is presented, taking into account interconnects, cracked cells, dielectric breakdown, delamination, and corrosion. Current design practices and reliability evaluations are also discussed. The conducted evaluation indicates that current module designs incorporate damage-resistant and fault-tolerant features which address field failure mechanisms observed to date.

  16. The new features of the ExaMe evaluation system and reliability of its fixed tests.

    Science.gov (United States)

    Martinková, P; Zvára, K; Zvárová, J; Zvára, K

    2006-01-01

    The ExaMe system for the evaluation of targeted knowledge has been in development since 1998. The new features of the ExaMe system are introduced in this paper. Especially, the new three-layer architecture is described. Besides the system itself, the properties of fixed tests in the ExaMe system are studied. In special detail, the reliability of the fixed tests is discussed. The theory background is explained and some limitations of the reliability are pointed out. Three characteristics used for estimation of reliability of educational tests are discussed: Cronbach's alpha, standardized item alpha and split half coefficient. The relation between these characteristics and reliability and between characteristics themselves is investigated. In more detail, the properties of Cronbach's alpha, the characteristics mostly used for the estimation of reliability, are discussed. A confidence interval is introduced for the characteristics. Since 2000, the serviceability of the ExaMe evaluation system as the supporting evaluation tool has been repeatedly shown at the courses of Ph.D. studies in biomedical informatics at Charles University in Prague. The ExaMe system also opens new possibilities for self-evaluation and distance learning, especially when connected with electronic books on the Internet. The estimation of reliability of tests contains some limitations. Keeping them in mind, we can still get some information about the quality of certain educational tests. Therefore, the estimation of reliability of the fixed tests is implemented in the ExaMe system.

  17. Ecological validity and reliability of an age-adapted endurance field test in young male soccer players

    DEFF Research Database (Denmark)

    Castagna, Carlo; Krustrup, Peter; D'Ottavio, Stefano

    2018-01-01

    The purpose of this study was to examine the reliability and the association with relevant match activities (ecological validity) of an age-adapted field test for intermittent high-intensity endurance known as Yo-Yo intermittent recovery level 1 children test (YYIR1C) in young male soccer players......-intensity metabolic power (r=0.46) distances. Match total distance was largely associated with YYIR1C (r=0.30). The results of this study showed that YYIR1C may be considered a valid and reliable field test for assessing intermittent high-intensity endurance in young male soccer players. Due to the relevance...... performance showed an excellent relative (ICC=0.94) and a good absolute reliability (TEM as %CV=5.1%). Very large and significant associations were found between YYIR1C performance and match high-intensity activity (r=0.53). Large correlations were found between YYIR1C and match sprinting (r=0.42) and high...

  18. Inventory of Motive of Preference for Conventional Paper-and-Pencil Tests: A Study of Validity and Reliability

    Science.gov (United States)

    Eser, Mehmet Taha; Dogan, Nuri

    2017-01-01

    Purpose: The objective of this study is to develop the Inventory of Motive of Preference for Conventional Paper-And-Pencil Tests and to evaluate students' motives for preferring written tests, short-answer tests, true/false tests or multiple-choice tests. This will add a measurement tool to the literature with valid and reliable results to help…

  19. Acoustic stapedial reflexes in healthy neonates: normative data and test-retest reliability.

    Science.gov (United States)

    Kei, Joseph

    2012-01-01

    The acoustic stapedial reflex (ASR) test provides useful information about the function of the auditory system. While it is frequently used with adults and children in a clinical setting, its use with young infants is limited. Presently, there are few data for neonates and inadequate research into the test-retest reliability of the ASR test. This study aimed to establish normative data and evaluate the test-retest reliability of the ASR test in healthy neonates. A cross-sectional experimental design was used to establish ASR normative data and assess the test-retest reliability of ASR thresholds obtained from healthy neonates. Sixty-eight full-term neonates with mean chronological age of 2.5 days (SD = 1.8 day), who passed the automated auditory brainstem response, transient evoked otoacoustic emission, and high frequency (1 kHz) tympanometry (HFT) tests. One randomly selected ear from each neonate was tested using TEOAE (transient evoked otoacoustic emission), HFT, and ASR tests using a 1 kHz probe tone. ASR thresholds were elicited by presenting pure tones of 0.5, 2, and 4 kHz and broadband noise (BBN) separately to the test ear in an ipsilateral stimulation mode. The ASR procedure was repeated to acquire retest data within the same testing session. Descriptive statistics, χ2, and analysis of variance with repeated measures tests were used to analyze ASR data. All neonates exhibited ASR when stimulated by tonal stimuli or BBN. The mean ASRTs (acoustic stapedial reflex thresholds) for the 0.5, 2, and 4 kHz tones were 81.6 ± 7.9, 71.3 ± 7.9, and 65.4 ± 8.7 dB HL, respectively. The mean ASRT for the BBN was estimated to be smaller than 57.2 dB HL, given the limitation of the equipment. The 95th percentiles of the ASRT were 95, 85, 80, and 75 dB HL for the 0.5, 2, and 4 kHz and BBN, respectively. The test-retest reliability of the ASR test for all stimuli was high, with no significant difference in mean ASRTs across the test and retest conditions. Test

  20. Comparison of reading performance tests concerning difficulty of sentences and paragraphs and their reliability

    NARCIS (Netherlands)

    Brussee, T.; van Nispen, R.M.A.; Klerkx, E.M.F.J.; Knol, D.L.; van Rens, G.H.M.B.

    2015-01-01

    In research and practice, sentences or paragraphs of reading tests may be randomly chosen to assess reading performance. This means that in addition to test reliability, all sentences or paragraphs should be reliable and equally difficult to read. The sentences and paragraphs of five (un-)

  1. Reliability and validity of the rey visual design learning test in primary school children

    NARCIS (Netherlands)

    Wilhelm, P.

    2004-01-01

    The Rey Visual Design Learning Test (Rey, 1964, in Spreen & Strauss, 1991) assesses immediate memory span, new learning and recognition for non-verbal material. Three studies are presented that focused on the reliability and validity of the RVDLT in primary school children. Test-retest reliability

  2. The test-retest reliability of the latent construct of executive function depends on whether tasks are represented as formative or reflective indicators.

    Science.gov (United States)

    Willoughby, Michael T; Kuhn, Laura J; Blair, Clancy B; Samek, Anya; List, John A

    2017-10-01

    This study investigates the test-retest reliability of a battery of executive function (EF) tasks with a specific interest in testing whether the method that is used to create a battery-wide score would result in differences in the apparent test-retest reliability of children's performance. A total of 188 4-year-olds completed a battery of computerized EF tasks twice across a period of approximately two weeks. Two different approaches were used to create a score that indexed children's overall performance on the battery-i.e., (1) the mean score of all completed tasks and (2) a factor score estimate which used confirmatory factor analysis (CFA). Pearson and intra-class correlations were used to investigate the test-retest reliability of individual EF tasks, as well as an overall battery score. Consistent with previous studies, the test-retest reliability of individual tasks was modest (rs ≈ .60). The test-retest reliability of the overall battery scores differed depending on the scoring approach (r mean  = .72; r factor_ score  = .99). It is concluded that the children's performance on individual EF tasks exhibit modest levels of test-retest reliability. This underscores the importance of administering multiple tasks and aggregating performance across these tasks in order to improve precision of measurement. However, the specific strategy that is used has a large impact on the apparent test-retest reliability of the overall score. These results replicate our earlier findings and provide additional cautionary evidence against the routine use of factor analytic approaches for representing individual performance across a battery of EF tasks.

  3. A Systematic Review of Statistical Methods Used to Test for Reliability of Medical Instruments Measuring Continuous Variables

    Directory of Open Access Journals (Sweden)

    Rafdzah Zaki

    2013-06-01

    Full Text Available   Objective(s: Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice.   Materials and Methods: In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. Results: The Intra-class Correlation Coefficient (ICC is the most popular method with 25 (60% studies having used this method followed by the comparing means (8 or 19%. Out of 25 studies using the ICC, only 7 (28% reported the confidence intervals and types of ICC used. Most studies (71% also tested the agreement of instruments. Conclusion: This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  4. Interrater reliability of the Volume-Viscosity Swallow Test; screening for dysphagia among hospitalized elderly medical patients.

    Science.gov (United States)

    Jørgensen, Lise Walther; Søndergaard, Kasper; Melgaard, Dorte; Warming, Susan

    2017-12-01

    Oropharyngeal dysphagia (OD) is prevalent among medical and geriatric patients admitted due to acute illness and it is associated with malnutrition, increased length of stay and increased mortality. A valid and reliable bedside screening test for patients at risk of OD is essential in order to detect patients in need of further assessment. The Volume-Viscosity Swallow Test (V-VST) has been shown to be a valid screening test for OD in mixed outpatient populations. However, as reliability of the test has yet to be investigated in a population of medical and geriatric patients admitted due to acute illness, we aimed to determine the interrater reliability of the V-VST in this clinical setting. Reporting in this study is in accordance with proposed guidelines for the reporting of reliability and agreement studies (GRRAS). In three Danish hospitals (CRD-BFH, CRD-GH, NDR-H) 11 skilled occupational therapists examined an unselected group of 110 patients admitted to geriatric or medical wards. In an overall agreement phase raters reached ≥80% agreement before data collection phase was commenced. The V-VST was applied to patients twice within maximum one hour by raters who administrated the test in an order based on randomization, blinded to each other's results. Agreement, Kappa values, weighed Kappa values and Kappa adjusted for bias and prevalence are reported. The interrater reliability of V-VST as screening test for OD in patients admitted to geriatric or medical wards was substantial with an overall Kappa value of 0.77 (95% CI 0.65-0.89) however interrater reliability varied among hospitals ranging from 0.37 (95% CI -0.01 to 0.41) to 0.85 (95% CI 0.75-1.00). Interrater reliability of the accompanying recommendations of volume and viscosity was moderate with a weighted kappa value of 0.55 (95% CI 0.37-0.73) for viscosity and 0.53 (95% CI 0.36-0.7) for volume. The overall prevalence of OD was 34.5%, ranging from 8% to 53.6% across hospitals. The prevalence and bias

  5. Test-Retest Reliability of a Survey to Measure Transport-Related Physical Activity in Adults

    Science.gov (United States)

    Badland, Hannah; Schofield, Grant

    2006-01-01

    The present research details test-retest reliability of a newly developed, telephone-administered TPA survey for adults. This instrument examines barriers, perceptions, and current travel behaviors to place of work/study and local convenience shops. Demonstrated test-retest reliability of the Active Friendly Environments-Transport-Related Physical…

  6. The Functional Test for Agility Performance is a Reliable Quick Decision-Making Test for Skilled Water Polo Players

    Directory of Open Access Journals (Sweden)

    Tucher Guilherme

    2015-06-01

    Full Text Available The reliability of the Functional Test for Agility Performance has only been evaluated in water polo players in a small group of novice athletes. Thus, the aim of this study was to evaluate the reliability of the Functional Test for Agility Performance in skilled water polo players. Forty-two athletes (17.81 ± 3.24 years old with a minimum of 5 years of competitive experience (7.05 ± 2.84 years and playing at the national or international level were evaluated. The Functional Test for Agility Performance is characterized as a specific open decision-making test where a tested player moves as quickly as possible in accordance to a pass made by another player. The time spent in the test was measured by two experienced coaches. Descriptive statistics, repeated measures analysis of variance (ANOVA, 95% limit of agreement (LOA, intraclass correlation coefficient (ICC and standard error of measurements (SEM were used for data analysis. Athletes completed the Functional Test for Agility Performance in 4.15 0.47 s. The ICC value was 0.87 (95% IC = 0.80-0.92. The SEM varied between 0.24 and 0.38 s. The LOA was 1.20 s and the CV average considering each individual trial was 6%. The Functional Test for Agility Performance was shown to be a reliable quick decision-making test for skilled water polo players.

  7. Test-retest reliability of evoked BOLD signals from a cognitive-emotive fMRI test battery.

    Science.gov (United States)

    Plichta, Michael M; Schwarz, Adam J; Grimm, Oliver; Morgen, Katrin; Mier, Daniela; Haddad, Leila; Gerdes, Antje B M; Sauer, Carina; Tost, Heike; Esslinger, Christine; Colman, Peter; Wilson, Frederick; Kirsch, Peter; Meyer-Lindenberg, Andreas

    2012-04-15

    Even more than in cognitive research applications, moving fMRI to the clinic and the drug development process requires the generation of stable and reliable signal changes. The performance characteristics of the fMRI paradigm constrain experimental power and may require different study designs (e.g., crossover vs. parallel groups), yet fMRI reliability characteristics can be strongly dependent on the nature of the fMRI task. The present study investigated both within-subject and group-level reliability of a combined three-task fMRI battery targeting three systems of wide applicability in clinical and cognitive neuroscience: an emotional (face matching), a motivational (monetary reward anticipation) and a cognitive (n-back working memory) task. A group of 25 young, healthy volunteers were scanned twice on a 3T MRI scanner with a mean test-retest interval of 14.6 days. FMRI reliability was quantified using the intraclass correlation coefficient (ICC) applied at three different levels ranging from a global to a localized and fine spatial scale: (1) reliability of group-level activation maps over the whole brain and within targeted regions of interest (ROIs); (2) within-subject reliability of ROI-mean amplitudes and (3) within-subject reliability of individual voxels in the target ROIs. Results showed robust evoked activation of all three tasks in their respective target regions (emotional task=amygdala; motivational task=ventral striatum; cognitive task=right dorsolateral prefrontal cortex and parietal cortices) with high effect sizes (ES) of ROI-mean summary values (ES=1.11-1.44 for the faces task, 0.96-1.43 for the reward task, 0.83-2.58 for the n-back task). Reliability of group level activation was excellent for all three tasks with ICCs of 0.89-0.98 at the whole brain level and 0.66-0.97 within target ROIs. Within-subject reliability of ROI-mean amplitudes across sessions was fair to good for the reward task (ICCs=0.56-0.62) and, dependent on the particular ROI

  8. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease.

    Science.gov (United States)

    Strouwen, Carolien; Molenaar, Esther A L M; Keus, Samyra H J; Münks, Liesbeth; Bloem, Bastiaan R; Nieuwboer, Alice

    2016-08-01

    Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains largely unknown. The purpose of this study was to assess the reliability of DT outcome measures in patients with PD. A repeated-measures design was used. Patients with PD ("on" medication, Mini-Mental State Examination score ≥24) performed 2 cognitive tasks (ie, backward digit span task and auditory Stroop task) and 1 functional task (ie, mobile phone task) in combination with walking. Tasks were assessed at 2 time points (same hour) with an interval of 6 weeks. Test-retest reliability was assessed for gait while performing each secondary task (DT gait) for both cognitive tasks while walking (DT cognitive) and for the functional task while walking (DT functional). Sixty-two patients with PD (age=39-89 years, Hoehn and Yahr stages II-III) were included in the study. Intraclass correlation coefficients (ICCs) showed excellent reliability for DT gait measures, ranging between .86 and .95 when combined with the digit span task, between .86 and .95 when combined with the auditory Stroop task, and between .72 and .90 when combined with the mobile phone task. The standard error of measurements for DT gait speed varied between 0.06 and 0.08 m/s, leading to minimal detectable changes between 0.16 and 0.22 m/s. With regard to DT cognitive measures, reaction times showed good-to-excellent reliability (digit span task: ICC=.75; auditory Stroop task: ICC=.82). The results cannot be generalized to patients with advanced disease or to other DT measures. In people with PD, DT measures proved to be reliable for use in clinical studies and look promising for use in clinical practice to assess improvements after DT training. Large effects, however, are needed to obtain meaningful effect sizes.

  9. Interrater and Test-Retest Reliability and Minimal Detectable Change of the Balance Evaluation Systems Test (BESTest) and Subsystems With Community-Dwelling Older Adults.

    Science.gov (United States)

    Wang-Hsu, Elizabeth; Smith, Susan S

    2017-01-10

    individual subsystem scores ranged from 0.72 to 0.89. The CVME (N = 70) of the BESTest total score was 4.1%. The CVME for the subsystem scores ranged from 5.0% to 10.7%. MDC (N = 70) for the BESTest total score at the 95% CI was 7.6%, or 8.2 points. MDC at the 95% CI for subsystem scores ranged from 11.7% to 19.0% (2.1-3.4 points). Results demonstrated generally good to excellent interrater and test-retest reliability in both the BESTest total and subsystem scores with community-dwelling older adults. The BESTest total and individual subsystem scores demonstrate good to excellent interrater and test-retest reliability with community-dwelling older adults. A change of 7.6% (8.2 points) or more in the BESTest total and a percentage change ranged from 11.7% to 19.0% (2.1-3.4 points) in the subsystem scores are suggested for clinicians to be 95% confident of true change when evaluating change in this population.

  10. Investigation of reliability, validity and normality Persian version of the California Critical Thinking Skills Test; Form B (CCTST

    Directory of Open Access Journals (Sweden)

    Khallli H

    2003-04-01

    Full Text Available Background: To evaluate the effectiveness of the present educational programs in terms of students' achieving problem solving, decision making and critical thinking skills, reliable, valid and standard instrument are needed. Purposes: To Investigate the Reliability, validity and Norm of CCTST Form.B .The California Critical Thinking Skills Test contain 34 multi-choice questions with a correct answer in the jive Critical Thinking (CT cognitive skills domain. Methods: The translated CCTST Form.B were given t0405 BSN nursing students ojNursing Faculties located in Tehran (Tehran, Iran and Shahid Beheshti Universitiesthat were selected in the through random sampling. In order to determine the face and content validity the test was translated and edited by Persian and English language professor and researchers. it was also confirmed by judgments of a panel of medical education experts and psychology professor's. CCTST reliability was determined with internal consistency and use of KR-20. The construct validity of the test was investigated with factor analysis and internal consistency and group difference. Results: The test coefficien for reliablity was 0.62. Factor Analysis indicated that CCTST has been formed from 5 factor (element namely: Analysis, Evaluation, lriference, Inductive and Deductive Reasoning. Internal consistency method shows that All subscales have been high and positive correlation with total test score. Group difference method between nursing and philosophy students (n=50 indicated that there is meaningfUl difference between nursing and philosophy students scores (t=-4.95,p=0.OOO1. Scores percentile norm also show that percentile offifty scores related to 11 raw score and 95, 5 percentiles are related to 17 and 6 raw score ordinary. Conclusions: The Results revealed that the questions test is sufficiently reliable as a research tool, and all subscales measure a single construct (Critical Thinking and are able to distinguished the

  11. Test-retest reliability and cross validation of the functioning everyday with a wheelchair instrument.

    Science.gov (United States)

    Mills, Tamara L; Holm, Margo B; Schmeler, Mark

    2007-01-01

    The purpose of this study was to establish the test-retest reliability and content validity of an outcomes tool designed to measure the effectiveness of seating-mobility interventions on the functional performance of individuals who use wheelchairs or scooters as their primary seating-mobility device. The instrument, Functioning Everyday With a Wheelchair (FEW), is a questionnaire designed to measure perceived user function related to wheelchair/scooter use. Using consumer-generated items, FEW Beta Version 1.0 was developed and test-retest reliability was established. Cross-validation of FEW Beta Version 1.0 was then carried out with five samples of seating-mobility users to establish content validity. Based on the content validity study, FEW Version 2.0 was developed and administered to seating-mobility consumers to examine its test-retest reliability. FEW Beta Version 1.0 yielded an intraclass correlation coefficient (ICC) Model (3,k) of .92, p content validity results revealed that FEW Beta Version 1.0 captured 55% of seating-mobility goals reported by consumers across five samples. FEW Version 2.0 yielded ICC(3,k) = .86, p content validity of FEW Version 2.0 was confirmed. FEW Beta Version 1.0 and FEW Version 2.0 were highly stable in their measurement of participants' seating-mobility goals over a 1-week interval.

  12. Effects of Differential Item Functioning on Examinees' Test Performance and Reliability of Test

    Science.gov (United States)

    Lee, Yi-Hsuan; Zhang, Jinming

    2017-01-01

    Simulations were conducted to examine the effect of differential item functioning (DIF) on measurement consequences such as total scores, item response theory (IRT) ability estimates, and test reliability in terms of the ratio of true-score variance to observed-score variance and the standard error of estimation for the IRT ability parameter. The…

  13. Test-retest reliability of the Clinical Learning Environment, Supervision and Nurse Teacher (CLES + T) scale.

    Science.gov (United States)

    Gustafsson, Margareta; Blomberg, Karin; Holmefur, Marie

    2015-07-01

    The Clinical Learning Environment, Supervision and Nurse Teacher (CLES + T) scale evaluates the student nurses' perception of the learning environment and supervision within the clinical placement. It has never been tested in a replication study. The aim of the present study was to evaluate the test-retest reliability of the CLES + T scale. The CLES + T scale was administered twice to a group of 42 student nurses, with a one-week interval. Test-retest reliability was determined by calculations of Intraclass Correlation Coefficients (ICCs) and weighted Kappa coefficients. Standard Error of Measurements (SEM) and Smallest Detectable Difference (SDD) determined the precision of individual scores. Bland-Altman plots were created for analyses of systematic differences between the test occasions. The results of the study showed that the stability over time was good to excellent (ICC 0.88-0.96) in the sub-dimensions "Supervisory relationship", "Pedagogical atmosphere on the ward" and "Role of the nurse teacher". Measurements of "Premises of nursing on the ward" and "Leadership style of the manager" had lower but still acceptable stability (ICC 0.70-0.75). No systematic differences occurred between the test occasions. This study supports the usefulness of the CLES + T scale as a reliable measure of the student nurses' perception of the learning environment within the clinical placement at a hospital. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Gearbox Reliability Collaborative Phase 3 Gearbox 3 Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wallen, Robb [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-10-01

    This document describes the Phase 3 test plan for the Gearbox Reliability Collaborative Gearbox #3. The primary test objective is to measure the planetary load sharing characteristics in the same conditions as the original gearbox design. If the measured load-sharing characteristics are close to the design model, the projected three-times improvement in planetary section predicted fatigue life and the efficacy of preloaded tapered roller bearings in mitigating the planetary bearing fatigue failure mode will have been demonstrated.

  15. Statistical Considerations in Choosing a Test Reliability Coefficient. ACT Research Report Series, 2012 (10)

    Science.gov (United States)

    Woodruff, David; Wu, Yi-Fang

    2012-01-01

    The purpose of this paper is to illustrate alpha's robustness and usefulness, using actual and simulated educational test data. The sampling properties of alpha are compared with the sampling properties of several other reliability coefficients: Guttman's lambda[subscript 2], lambda[subscript 4], and lambda[subscript 6]; test-retest reliability;…

  16. Reliability Engineering

    International Nuclear Information System (INIS)

    Lee, Sang Yong

    1992-07-01

    This book is about reliability engineering, which describes definition and importance of reliability, development of reliability engineering, failure rate and failure probability density function about types of it, CFR and index distribution, IFR and normal distribution and Weibull distribution, maintainability and movability, reliability test and reliability assumption in index distribution type, normal distribution type and Weibull distribution type, reliability sampling test, reliability of system, design of reliability and functionality failure analysis by FTA.

  17. Reliability of candida skin test in the evaluation of T-cell function in ...

    African Journals Online (AJOL)

    Ehab

    2017-01-23

    Jan 23, 2017 ... considered generally reliable under the age of 1 year.6 ... We sought to investigate the reliability of manually ... Conclusion: Candida intradermal test is a cost- effective ..... Ballow M. Historical perspectives in the diagnosis.

  18. Test-retest reliability of jump execution variables using mechanography: a comparison of jump protocols.

    Science.gov (United States)

    Fitzgerald, John S; Johnson, LuAnn; Tomkinson, Grant; Stein, Jesse; Roemmich, James N

    2018-05-01

    Mechanography during the vertical jump may enhance screening and determining mechanistic causes underlying physical performance changes. Utility of jump mechanography for evaluation is limited by scant test-retest reliability data on force-time variables. This study examined the test-retest reliability of eight jump execution variables assessed from mechanography. Thirty-two women (mean±SD: age 20.8 ± 1.3 yr) and 16 men (age 22.1 ± 1.9 yr) attended a familiarization session and two testing sessions, all one week apart. Participants performed two variations of the squat jump with squat depth self-selected and controlled using a goniometer to 80º knee flexion. Test-retest reliability was quantified as the systematic error (using effect size between jumps), random error (using coefficients of variation), and test-retest correlations (using intra-class correlation coefficients). Overall, jump execution variables demonstrated acceptable reliability, evidenced by small systematic errors (mean±95%CI: 0.2 ± 0.07), moderate random errors (mean±95%CI: 17.8 ± 3.7%), and very strong test-retest correlations (range: 0.73-0.97). Differences in random errors between controlled and self-selected protocols were negligible (mean±95%CI: 1.3 ± 2.3%). Jump execution variables demonstrated acceptable reliability, with no meaningful differences between the controlled and self-selected jump protocols. To simplify testing, a self-selected jump protocol can be used to assess force-time variables with negligible impact on measurement error.

  19. How stable are quantitative sensory testing measurements over time? Report on 10-week reliability and agreement of results in healthy volunteers

    Directory of Open Access Journals (Sweden)

    Nothnagel H

    2017-08-01

    Full Text Available Helen Nothnagel,1,2,* Christian Puta,1,3,* Thomas Lehmann,4 Philipp Baumbach,5 Martha B Menard,6,7 Brunhild Gabriel,1 Holger H W Gabriel,1 Thomas Weiss,8 Frauke Musial2 1Department of Sports Medicine and Health Promotion, Friedrich Schiller University, Jena, Germany; 2Department of Community Medicine, National Research Center in Complementary and Alternative Medicine, UiT, The Arctic University of Norway, Tromsø, Norway; 3Center for Interdisciplinary Prevention of Diseases Related to Professional Activities, 4Department of Medical Statistics, Computer Sciences and Documentation, Friedrich Schiller University, 5Department of Anesthesiology and Intensive Care Medicine, University Hospital Jena, Germany; 6Crocker Institute, Kiawah Island, SC, 7School of Integrative Medicine and Health Sciences, Saybrook University, Oakland, CA, USA; 8Department of Biological and Clinical Psychology, Friedrich Schiller University, Jena, Germany *These authors contributed equally to this work Background: Quantitative sensory testing (QST is a diagnostic tool for the assessment of the somatosensory system. To establish QST as an outcome measure for clinical trials, the question of how similar the measurements are over time is crucial. Therefore, long-term reliability and limits of agreement of the standardized QST protocol of the German Research Network on Neuropathic Pain were tested. Methods: QST on the lower back and hand dorsum (dominant hand were assessed twice in 22 healthy volunteers (10 males and 12 females; mean age: 46.6±13.0 years, with sessions separated by 10.0±2.9 weeks. All measurements were performed by one investigator. To investigate long-term reliability and agreement of QST, differences between the two measurements, correlation coefficients, intraclass correlation coefficients (ICCs, Bland–Altman plots (limits of agreement, and standard error of measurement were used. Results: Most parameters of the QST were reliable over 10 weeks in

  20. Reliability, validity and usefulness of 30-15 Intermittent Fitness Test in Female Soccer Players

    Directory of Open Access Journals (Sweden)

    Nedim Čović

    2016-11-01

    Full Text Available PURPOSE: The aim of this study was to examine the reliability, validity and usefulness of the 30-15IFT in competitive female soccer players. METHODS: Seventeen elite female soccer players participated in the study. A within subject test-retest study design was utilized to assess the reliability of the 30-15 intermittent fitness test (IFT. Seven days prior to 30-15IFT, subjects performed a continuous aerobic running test (CT under laboratory conditions to assess the criterion validity of the 30-15IFT. End running velocity (VCT and VIFT, peak heart rate (HRpeak and maximal oxygen consumption (VO2max were collected and/or estimated for both tests. RESULTS: VIFT (ICC = 0.91; CV = 1.8%, HRpeak (ICC = 0.94; CV = 1.2%, and VO2max (ICC = 0.94; CV = 1.6% obtained from the 30-15IFT were all deemed highly reliable (p>0.05. Pearson product moment correlations between the CT and 30-15IFT for VO2max, HRpeak and end running velocity were large (r = 0.67, p=0.013, very large (r = 0.77, p=0.02 and large (r = 0.57, p=0.042, respectively. CONCLUSION: Current findings suggest that the 30 -15IFT is a valid and reliable intermittent aerobic fitness test of elite female soccer players. The findings have also provided practitioners with evidence to support the accurate detection of meaningful individual changes in VIFT of 0.5 km/h (1 stage and HRpeak of 2 bpm. This information may assist coaches in monitoring ‘real’ aerobic fitness changes to better inform training of female intermittent team sport athletes. Lastly, coaches could use the 30-15IFT as a practical alternative to laboratory based assessments to assess and monitor intermittent aerobic fitness changes in their athletes. Keywords: 30-15 intermittent fitness test, aerobic, cardiorespiratory fitness, intermittent activity, soccer, high intensity interval training.

  1. Reliability assessment for metallized film pulse capacitors with accelerated degradation test

    International Nuclear Information System (INIS)

    Zhao Jianyin; Liu Fang; Xi Wenjun; He Shaobo; Wei Xiaofeng

    2011-01-01

    The high energy density self-healing metallized film pulse capacitor has been applied to all kinds of laser facilities for their power conditioning systems, whose reliability is straightforward affected by the reliability level of capacitors. Reliability analysis of highly reliable devices, such as metallized film capacitors, is a challenge due to cost and time restriction. Accelerated degradation test provides a way to predict its life cost and time effectively. A model and analyses for accelerated degradation data of metallized film capacitors are described. Also described is a method for estimating the distribution of failure time. The estimation values of the unknown parameters in this model are 9.066 9 x 10 -8 and 0.022 1. Both the failure probability density function (PDF) and the cumulative distribution function (CDF) can be presented by this degradation failure model. Based on these estimation values and the PDF/CDF, the reliability model of the metallized film capacitors is obtained. According to the reliability model, the probability of the capacitors surviving to 20 000 shot is 0.972 4. (authors)

  2. Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

    Science.gov (United States)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.

    2010-01-01

    Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

  3. The minimum sit-to-stand height test: reliability, responsiveness and relationship to leg muscle strength.

    Science.gov (United States)

    Schurr, Karl; Sherrington, Catherine; Wallbank, Geraldine; Pamphlett, Patricia; Olivetti, Lynette

    2012-07-01

    To determine the reliability of the minimum sit-to-stand height test, its responsiveness and its relationship to leg muscle strength among rehabilitation unit inpatients and outpatients. Reliability study using two measurers and two test occasions. Secondary analysis of data from two clinical trials. Inpatient and outpatient rehabilitation services in three public hospitals. Eighteen hospital patients and five others participated in the reliability study. Seventy-two rehabilitation unit inpatients and 80 outpatients participated in the clinical trials. The minimum sit-to-stand height test was assessed using a standard procedure. For the reliability study, a second tester repeated the minimum sit-to-stand height test on the same day. In the inpatient clinical trial the measures were repeated two weeks later. In the outpatient trial the measures were repeated five weeks later. Knee extensor muscle strength was assessed in the clinical trials using a hand-held dynamometer. The reliability for the minimum sit-to-stand height test was excellent (intraclass correlation coefficient (ICC) 0.91, 95% confidence interval (CI) 0.81-0.96). The standard error of measurement was 34 mm. Responsiveness was moderate in the inpatient trial (effect size: 0.53) but small in the outpatient trial (effect size: 0.16). A small proportion (8-17%) of variability in minimum sit-to-stand height test was explained by knee extensor muscle strength. The minimum sit-to-stand height test has excellent reliability and moderate responsiveness in an inpatient rehabilitation setting. Responsiveness in an outpatient rehabilitation setting requires further investigation. Performance is influenced by factors other than knee extensor muscle strength.

  4. Test-retest Agreement and Reliability of Quantitative Sensory Testing 1 Year After Breast Cancer Surgery

    DEFF Research Database (Denmark)

    Andersen, Kenneth Geving; Kehlet, Henrik; Aasvang, Eske Kvanner

    2015-01-01

    .5 SD) than within-patient variation (0.23 to 3.55 SD). There were no significant differences between pain and pain-free patients. The individual test-retest variability was higher on the operated side compared with the nonoperated side. DISCUSSION: The QST protocol reliability allows for group......OBJECTIVES: Quantitative sensory testing (QST) is used to assess sensory dysfunction and nerve damage by examining psychophysical responses to controlled, graded stimuli such as mechanical and thermal detection and pain thresholds. In the breast cancer population, 4 studies have used QST to examine...... persistent pain after breast cancer treatment, suggesting neuropathic pain being a prominent pain mechanism. However, the agreement and reliability of QST has not been described in the postsurgical breast cancer population, hindering exact interpretation of QST studies in this population. The aim...

  5. Test-retest reliability, smallest real difference and concurrent validity of six different balance tests on young people with mild to moderate intellectual disability.

    Science.gov (United States)

    Blomqvist, Sven; Wester, Anita; Sundelin, Gunnevi; Rehn, Börje

    2012-12-01

    Some studies have reported that people with intellectual disability may have reduced balance ability compared with the population in general. However, none of these studies involved adolescents, and the reliability and validity of balance tests in this population are not known. The purpose of this study was to examine the reliability of six different balance tests and to investigate their concurrent validity. Test-retest reliability assessment. All subjects were recruited from a special school for people with intellectual disability in Bollnäs, Sweden. Eighty-nine adolescents (35 females and 54 males) with mild to moderate intellectual disability with a mean age of 18 years (range 16 to 20 years). All subjects followed the same test protocol on two occasions within an 11-day period. Balance test performances. Intraclass correlation coefficients greater than 0.80 were achieved for four of the balance tests: Extended Timed Up and Go Test, Modified Functional Reach Test, One-leg Stance Test and Force Platform Test. The smallest real differences ranged from 12% to 40%; less than 20% is considered to be low. Concurrent validity among these balance tests varied between no and low correlation. The results indicate that these tests could be used to evaluate changes in balance ability over time in people with mild to moderate intellectual disability. The low concurrent validity illustrates the importance of knowing more about the influence of various sensory subsystems that are significant for balance among adolescents with intellectual disability. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  6. NDT Reliability - Final Report. Reliability in non-destructive testing (NDT) of the canister components

    Energy Technology Data Exchange (ETDEWEB)

    Pavlovic, Mato; Takahashi, Kazunori; Mueller, Christina; Boehm, Rainer (BAM, Federal Inst. for Materials Research and Testing, Berlin (Germany)); Ronneteg, Ulf (Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden))

    2008-12-15

    This report describes the methodology of the reliability investigation performed on the ultrasonic phased array NDT system, developed by SKB in collaboration with Posiva, for inspection of the canisters for permanent storage of nuclear spent fuel. The canister is composed of a cast iron insert surrounded by a copper shell. The shell is composed of the tube and the lid/base which are welded to the tube after the fuel has been place, in the tube. The manufacturing process of the canister parts and the welding process are described. Possible defects, which might arise in the canister components during the manufacturing or in the weld during the welding, are identified. The number of real defects in manufactured components have been limited. Therefore the reliability of the NDT system has been determined using a number of test objects with artificial defects. The reliability analysis is based on the signal response analysis. The conventional signal response analysis is adopted and further developed before applied on the modern ultrasonic phased-array NDT system. The concept of multi-parameter a, where the response of the NDT system is dependent on more than just one parameter, is introduced. The weakness of use of the peak signal response in the analysis is demonstrated and integration of the amplitudes in the C-scan is proposed as an alternative. The calculation of the volume POD, when the part is inspected with more configurations, is also presented. The reliability analysis is supported by the ultrasonic simulation based on the point source synthesis method

  7. Test-Retest Reliability of Rating of Perceived Exertion and Agreement With 1-Repetition Maximum in Adults.

    Science.gov (United States)

    Bove, Allyn M; Lynch, Andrew D; DePaul, Samantha M; Terhorst, Lauren; Irrgang, James J; Fitzgerald, G Kelley

    2016-09-01

    Study Design Clinical measurement. Background It has been suggested that rating of perceived exertion (RPE) may be a useful alternative to 1-repetition maximum (1RM) to determine proper resistance exercise dosage. However, the test-retest reliability of RPE for resistance exercise has not been determined. Additionally, prior research regarding the relationship between 1RM and RPE is conflicting. Objectives The purpose of this study was to (1) determine test-retest reliability of RPE related to resistance exercise and (2) assess agreement between percentages of 1RM and RPE during quadriceps resistance exercise. Methods A sample of participants with and without knee pathology completed a series of knee extension exercises and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale, then repeated the procedure 1 to 2 weeks later for test-retest reliability. To determine agreement between RPE and 1RM, participants completed knee extension exercises at various percentages of their 1RM (10% to 130% of predicted 1RM) and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale. Percent agreement was calculated between the 1RM and RPE at each resistance interval. Results The intraclass correlation coefficient indicated excellent test-retest reliability of RPE for quadriceps resistance exercises (intraclass correlation coefficient = 0.895; 95% confidence interval: 0.866, 0.918). Overall percent agreement between RPE and 1RM was 60%, but agreement was poor within the ranges that would typically be used for training (50% 1RM for muscle endurance, 70% 1RM and greater for strength). Conclusion Test-retest reliability of perceived exertion during quadriceps resistance exercise was excellent. However, agreement between the RPE and 1RM was poor, especially in common training zones for knee extensor strengthening. J Orthop Sports Phys Ther 2016;46(9):768-774. Epub 5 Aug 2016. doi:10.2519/jospt.2016.6498.

  8. RELIABILITY OF THE ONE REPETITION-MAXIMUM POWER CLEAN TEST IN ADOLESCENT ATHLETES

    Science.gov (United States)

    Faigenbaum, Avery D.; McFarland, James E.; Herman, Robert; Naclerio, Fernando; Ratamess, Nicholas A.; Kang, Jie; Myer, Gregory D.

    2013-01-01

    Although the power clean test is routinely used to assess strength and power performance in adult athletes, the reliability of this measure in younger populations has not been examined. Therefore, the purpose of this study was to determine the reliability of the one repetition maximum (1 RM) power clean in adolescent athletes. Thirty-six male athletes (age 15.9 ± 1.1 yrs, body mass 79.1 ± 20.3 kg, height 175.1 ±7.4 cm) who had more than 1 year of training experience with weightlifting exercises performed a 1 RM power clean on two nonconsecutive days in the afternoon following standardized procedures. All test procedures were supervised by a senior level weightlifting coach and consisted of a systematic progression in test load until the maximum resistance that could be lifted for one repetition using proper exercise technique was determined. Data were analyzed using an intraclass correlation coefficient (ICC [2,k]), Pearson correlation coefficient (r), repeated measures ANOVA, Bland-Altman plot, and typical error analyses. Analysis of the data revealed that the test measures were highly reliable demonstrating a test-retest ICC of 0.98 (95% CI = 0.96–0.99). Testing also demonstrated a strong relationship between 1 RM measures on trial 1 and trial 2 (r=0.98, pinjuries occurred during the study period and the testing protocol was well-tolerated by all subjects. These findings indicate that 1 RM power clean testing has a high degree of reproducibility in trained male adolescent athletes when standardized testing procedures are followed and qualified instruction is present. PMID:22233786

  9. Orthopaedic nurses' knowledge and interrater reliability of neurovascular assessments with 2-point discrimination test.

    Science.gov (United States)

    Turney, Jennifer; Raley Noble, Deana; Kim, Son Chae

    2013-01-01

    : This study was conducted to evaluate the effects of education on knowledge and interrater reliability of neurovascular assessments with 2-point discrimination (2-PD) test among pediatric orthopaedic nurses. : A pre- and posttest study was done among 60 nurses attending 2-hour educational sessions. Neurovascular assessments with 2-PD test were performed on 64 casted pediatric patients by the nurses and 5 nurse experts before and after the educational sessions. : The mean neurovascular assessment knowledge score was improved at posteducation compared with the preeducation (p < .001). The 2-PD test interrater reliability also improved from Cohen's kappa value of 0.24-0.48 at posteducation. : The 2-hour educational session may be effective in improving nurses' knowledge and the interrater reliability of neurovascular assessment with 2-PD test.

  10. Note: An online testing method for lifetime projection of high power light-emitting diode under accelerated reliability test.

    Science.gov (United States)

    Chen, Qi; Chen, Quan; Luo, Xiaobing

    2014-09-01

    In recent years, due to the fast development of high power light-emitting diode (LED), its lifetime prediction and assessment have become a crucial issue. Although the in situ measurement has been widely used for reliability testing in laser diode community, it has not been applied commonly in LED community. In this paper, an online testing method for LED life projection under accelerated reliability test was proposed and the prototype was built. The optical parametric data were collected. The systematic error and the measuring uncertainty were calculated to be within 0.2% and within 2%, respectively. With this online testing method, experimental data can be acquired continuously and sufficient amount of data can be gathered. Thus, the projection fitting accuracy can be improved (r(2) = 0.954) and testing duration can be shortened.

  11. The Validity and Reliability Test of the Indonesian Version of Gastroesophageal Reflux Disease Quality of Life (GERD-QOL) Questionnaire.

    Science.gov (United States)

    Siahaan, Laura A; Syam, Ari F; Simadibrata, Marcellus; Setiati, Siti

    2017-01-01

    to obtain a valid and reliable GERD-QOL questionnaire for Indonesian application. at the initial stage, the GERD-QOL questionnaire was first translated into Indonesian language and the translated questionnaire was subsequently translated back into the original language (back-to-back translation). The results were evaluated by the researcher team and therefore, an Indonesian version of GERD-QOL questionnaire was developed. Ninety-one patients who had been clinically diagnosed with GERD based on the Montreal criteria were interviewed using the Indonesian version of GERD-QOL questionnaire and the SF 36 questionnaire. The validity was evaluated using a method of construct validity and external validity, and reliability can be tested by the method of internal consistency and test retest. the Indonesian version of GERD-QOL questionnaire had a good internal consistency reliability with a Cronbach Alpha of 0.687-0.842 and a good test retest reliability with an intra-class correlation coefficient of 0.756-0.936; pGERD-QOL questionnaire has been proven valid and reliable to evaluate the quality of life of GERD patients.

  12. 75 FR 50853 - Special Conditions: Cirrus Design Corporation Model SF50 Airplane; Function and Reliability Testing

    Science.gov (United States)

    2010-08-18

    ... airplanes. 1. Function and Reliability Testing. Flight tests: In place of 14 CFR 21.35(b)(2), the following...; Function and Reliability Testing AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final special... to CAR part 3 became effective January 15, 1951, and deleted the service test requirements in Section...

  13. Reliability and Validity of the Inline Skating Skill Test

    Directory of Open Access Journals (Sweden)

    Ivan Radman, Lana Ruzic, Viktoria Padovan, Vjekoslav Cigrovski, Hrvoje Podnar

    2016-09-01

    Full Text Available This study aimed to examine the reliability and validity of the inline skating skill test. Based on previous skating experience forty-two skaters (26 female and 16 male were randomized into two groups (competitive level vs. recreational level. They performed the test four times, with a recovery time of 45 minutes between sessions. Prior to testing, the participants rated their skating skill using a scale from 1 to 10. The protocol included performance time measurement through a course, combining different skating techniques. Trivial changes in performance time between the repeated sessions were determined in both competitive females/males and recreational females/males (-1.7% [95% CI: -5.8–2.6%] – 2.2% [95% CI: 0.0–4.5%]. In all four subgroups, the skill test had a low mean within-individual variation (1.6% [95% CI: 1.2–2.4%] – 2.7% [95% CI: 2.1–4.0%] and high mean inter-session correlation (ICC = 0.97 [95% CI: 0.92–0.99] – 0.99 [95% CI: 0.98–1.00]. The comparison of detected typical errors and smallest worthwhile changes (calculated as standard deviations × 0.2 revealed that the skill test was able to track changes in skaters’ performances. Competitive-level skaters needed shorter time (24.4–26.4%, all p < 0.01 to complete the test in comparison to recreational-level skaters. Moreover, moderate correlation (ρ = 0.80–0.82; all p < 0.01 was observed between the participant’s self-rating and achieved performance times. In conclusion, the proposed test is a reliable and valid method to evaluate inline skating skills in amateur competitive and recreational level skaters. Further studies are needed to evaluate the reproducibility of this skill test in different populations including elite inline skaters.

  14. Influences on the Test-Retest Reliability of Functional Connectivity MRI and its Relationship with Behavioral Utility.

    Science.gov (United States)

    Noble, Stephanie; Spann, Marisa N; Tokoglu, Fuyuze; Shen, Xilin; Constable, R Todd; Scheinost, Dustin

    2017-11-01

    Best practices are currently being developed for the acquisition and processing of resting-state magnetic resonance imaging data used to estimate brain functional organization-or "functional connectivity." Standards have been proposed based on test-retest reliability, but open questions remain. These include how amount of data per subject influences whole-brain reliability, the influence of increasing runs versus sessions, the spatial distribution of reliability, the reliability of multivariate methods, and, crucially, how reliability maps onto prediction of behavior. We collected a dataset of 12 extensively sampled individuals (144 min data each across 2 identically configured scanners) to assess test-retest reliability of whole-brain connectivity within the generalizability theory framework. We used Human Connectome Project data to replicate these analyses and relate reliability to behavioral prediction. Overall, the historical 5-min scan produced poor reliability averaged across connections. Increasing the number of sessions was more beneficial than increasing runs. Reliability was lowest for subcortical connections and highest for within-network cortical connections. Multivariate reliability was greater than univariate. Finally, reliability could not be used to improve prediction; these findings are among the first to underscore this distinction for functional connectivity. A comprehensive understanding of test-retest reliability, including its limitations, supports the development of best practices in the field. © The Author 2017. Published by Oxford University Press.

  15. INTRA-RATER RELIABILITY OF THE MULTIPLE SINGLE-LEG HOP-STABILIZATION TEST AND RELATIONSHIPS WITH AGE, LEG DOMINANCE AND TRAINING.

    Science.gov (United States)

    Sawle, Leanne; Freeman, Jennifer; Marsden, Jonathan

    2017-04-01

    Balance is a complex construct, affected by multiple components such as strength and co-ordination. However, whilst assessing an athlete's dynamic balance is an important part of clinical examination, there is no gold standard measure. The multiple single-leg hop-stabilization test is a functional test which may offer a method of evaluating the dynamic attributes of balance, but it needs to show adequate intra-tester reliability. The purpose of this study was to assess the intra-rater reliability of a dynamic balance test, the multiple single-leg hop-stabilization test on the dominant and non-dominant legs. Intra-rater reliability study. Fifteen active participants were tested twice with a 10-minute break between tests. The outcome measure was the multiple single-leg hop-stabilization test score, based on a clinically assessed numerical scoring system. Results were analysed using an Intraclass Correlations Coefficient (ICC 2,1 ) and Bland-Altman plots. Regression analyses explored relationships between test scores, leg dominance, age and training (an alpha level of p = 0.05 was selected). ICCs for intra-rater reliability were 0.85 for the dominant and non-dominant legs (confidence intervals = 0.62-0.95 and 0.61-0.95 respectively). Bland-Altman plots showed scores within two standard deviations. A significant correlation was observed between the dominant and non-dominant leg on balance scores (R 2 =0.49, ptest demonstrated strong intra-tester reliability with active participants. Younger participants who trained more, have better balance scores. This test may be a useful measure for evaluating the dynamic attributes of balance. 3.

  16. Construct validity and reliability of automated body reaction test ...

    African Journals Online (AJOL)

    Automated Body Reaction Test (ABRT) is a new device for skills and physical assessment instrument to measure ability on react, move quickly and accurately in accordance with stimulus. A total of 474 subjects aged 7-17 years old were randomly selected for the construct validity (n=330) and reliability (n=144). The ABRT ...

  17. Reliability of intra-oral quantitative sensory testing (QST) in patients with atypical odontalgia and healthy controls - a multicentre study.

    Science.gov (United States)

    Baad-Hansen, L; Pigg, M; Yang, G; List, T; Svensson, P; Drangsholt, M

    2015-02-01

    The reliability of comprehensive intra-oral quantitative sensory testing (QST) protocol has not been examined systematically in patients with chronic oro-facial pain. The aim of the present multicentre study was to examine test-retest and interexaminer reliability of intra-oral QST measures in terms of absolute values and z-scores as well as within-session coefficients of variation (CV) values in patients with atypical odontalgia (AO) and healthy pain-free controls. Forty-five patients with AO and 68 healthy controls were subjected to bilateral intra-oral gingival QST and unilateral extratrigeminal QST (thenar) on three occasions (twice on 1 day by two different examiners and once approximately 1 week later by one of the examiners). Intra-class correlation coefficients and kappa values for interexaminer and test-retest reliability were computed. Most of the standardised intra-oral QST measures showed fair to excellent interexaminer (9-12 of 13 measures) and test-retest (7-11 of 13 measures) reliability. Furthermore, no robust differences in reliability measures or within-session variability (CV) were detected between patients with AO and the healthy reference group. These reliability results in chronic orofacial pain patients support earlier suggestions based on data from healthy subjects that intra-oral QST is sufficiently reliable for use as a part of a comprehensive evaluation of patients with somatosensory disturbances or neuropathic pain in the trigeminal region. © 2014 John Wiley & Sons Ltd.

  18. Short-term test-retest-reliability of conditioned pain modulation using the cold-heat-pain method in healthy subjects and its correlation to parameters of standardized quantitative sensory testing.

    Science.gov (United States)

    Gehling, Julia; Mainka, Tina; Vollert, Jan; Pogatzki-Zahn, Esther M; Maier, Christoph; Enax-Krumova, Elena K

    2016-08-05

    Conditioned Pain Modulation (CPM) is often used to assess human descending pain inhibition. Nine different studies on the test-retest-reliability of different CPM paradigms have been published, but none of them has investigated the commonly used heat-cold-pain method. The results vary widely and therefore, reliability measures cannot be extrapolated from one CPM paradigm to another. Aim of the present study was to analyse the test-retest-reliability of the common heat-cold-pain method and its correlation to pain thresholds. We tested the short-term test-retest-reliability within 40 ± 19.9 h using a cold-water immersion (10 °C, left hand) as conditioning stimulus (CS) and heat pain (43-49 °C, pain intensity 60 ± 5 on the 101-point numeric rating scale, right forearm) as test stimulus (TS) in 25 healthy right-handed subjects (12females, 31.6 ± 14.1 years). The TS was applied 30s before (TSbefore), during (TSduring) and after (TSafter) the 60s CS. The difference between the pain ratings for TSbefore and TSduring represents the early CPM-effect, between TSbefore and TSafter the late CPM-effect. Quantitative sensory testing (QST, DFNS protocol) was performed on both sessions before the CPM assessment. paired t-tests, Intraclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD), Pearson's correlation, Bland-Altman analysis, significance level p Pain ratings during CPM correlated significantly (ICC: 0.411…0.962) between both days, though ratings for TSafter were lower on day 2 (p pain thresholds. The short-term test-retest-reliability of the early CPM-effect using the heat-cold-pain method in healthy subjects achieved satisfying results in terms of the ICC. The SRD of the early CPM effect showed that an individual change of > 20 NRS can be attributed to a real change rather than chance. The late CPM-effect was weaker and not reliable.

  19. Round robin test programmes in the reliability of thick section ultrasonic inspections: state of the art report

    International Nuclear Information System (INIS)

    Watkins, B.

    1987-03-01

    Inspection reliability is firstly defined and it is shown how difficult it is to be assessed as the influence of such factors as human performance, equipment malfunction and intrinsic technique capability are difficult to quantify. The manufacture of round robin test specimens is then considered: types of flaw, fabrication of test samples. The results of various round robin test programmes that have been carried out to determine both the capability and reliability of NDE to detect and size flaws in steel section for thick sections directly relevant to the requirements of the nuclear industry, are then reviewed and discussed: US Pressure Vessel research committee programme, PISC I Programme, the defect detection trials, and PISC II Programme

  20. Diagnostic reliability of MMPI-2 computer-based test interpretations.

    Science.gov (United States)

    Pant, Hina; McCabe, Brian J; Deskovitz, Mark A; Weed, Nathan C; Williams, John E

    2014-09-01

    Reflecting the common use of the MMPI-2 to provide diagnostic considerations, computer-based test interpretations (CBTIs) also typically offer diagnostic suggestions. However, these diagnostic suggestions can sometimes be shown to vary widely across different CBTI programs even for identical MMPI-2 profiles. The present study evaluated the diagnostic reliability of 6 commercially available CBTIs using a 20-item Q-sort task developed for this study. Four raters each sorted diagnostic classifications based on these 6 CBTI reports for 20 MMPI-2 profiles. Two questions were addressed. First, do users of CBTIs understand the diagnostic information contained within the reports similarly? Overall, diagnostic sorts of the CBTIs showed moderate inter-interpreter diagnostic reliability (mean r = .56), with sorts for the 1/2/3 profile showing the highest inter-interpreter diagnostic reliability (mean r = .67). Second, do different CBTIs programs vary with respect to diagnostic suggestions? It was found that diagnostic sorts of the CBTIs had a mean inter-CBTI diagnostic reliability of r = .56, indicating moderate but not strong agreement across CBTIs in terms of diagnostic suggestions. The strongest inter-CBTI diagnostic agreement was found for sorts of the 1/2/3 profile CBTIs (mean r = .71). Limitations and future directions are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  1. Feasibility and Reliability of Physical Fitness Tests in Older Adults with Intellectual Disability: A Pilot Study

    Science.gov (United States)

    Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    2012-01-01

    Background: Physical fitness is relevant for wellbeing and health, but knowledge on the feasibility and reliability of instruments to measure physical fitness for older adults with intellectual disability is lacking. Methods: Feasibility and test-retest reliability of a physical fitness test battery (Box and Block Test, Response Time Test, walking…

  2. 75 FR 29962 - Special Conditions: Cirrus Design Corporation Model SF50 Airplane; Function and Reliability Testing

    Science.gov (United States)

    2010-05-28

    ... SF50 airplanes. 1. Function and Reliability Testing Flight tests: In place of 14 CFR part 21.35(b)(2... Reliability Testing AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed special..., 1951, and deleted the service test requirements in Section 3.19 for airplanes of 6,000 pounds maximum...

  3. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    .08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability...

  4. Multi Directional Repeated Sprint Is a Valid and Reliable Test for Assessment of Junior Handball Players

    Directory of Open Access Journals (Sweden)

    Amin Daneshfar

    2018-04-01

    Full Text Available The aim of the present study was to examine the validity and reliability of a 10 × (6 × 5 m multi-directional repeated sprint ability test (RSM in elite young team handball (TH players. Participants were members of the Iranian national team (n = 20, age 16.4 ± 0.7 years, weight 82.5 ± 5.5 kg, height 184.8 ± 4.6 cm, body fat 15.4 ± 4.3%. The validity of RSM was tested against a 10 × (15 + 15 m repeated sprint ability test (RSA, Yo-Yo Intermittent Recovery test Level 1 (Yo-Yo IR1, squat jump (SJ and countermovement jump (CMJ. To test the reliability of RSM, the participants repeated the testing sessions of RSM and RSA 1 week later. Both RSA and RSM tests showed good to excellent reliability of the total time (TT, best time (BT, and weakest time (WT. The results of the correlation analysis showed significant inverse correlations between maximum aerobic capacity and TT in RSA (r = −0.57, p ≤ 0.05 and RSM (r = −0.76, p ≤ 0.01. There was also a significant inverse correlation between maximum aerobic capacity with fatigue index (FI in RSA test (r = −0.64, p ≤ 0.01 and in RSM test (r = −0.53, p ≤ 0.05. BT, WT, and TT of RSA was largely-to-very largely correlated with BT (r = 0.58, p ≤ 0.01, WT (r = 0.62, p ≤ 0.01, and TT (r = 0.65, p ≤ 0.01 of RSM. BT in RSM was also correlated with FI in RSM (r = 0.88, p ≤ 0.01. In conclusion, based on the findings of the current study, the recently developed RSM test is a valid and reliable test and should be utilized for assessment of repeated sprint ability in handball players.

  5. Multi Directional Repeated Sprint Is a Valid and Reliable Test for Assessment of Junior Handball Players

    Science.gov (United States)

    Daneshfar, Amin; Gahreman, Daniel E.; Koozehchian, Majid S.; Amani Shalamzari, Sadegh; Hassanzadeh Sablouei, Mozhgan; Rosemann, Thomas; Knechtle, Beat; Nikolaidis, Pantelis T.

    2018-01-01

    The aim of the present study was to examine the validity and reliability of a 10 × (6 × 5 m) multi-directional repeated sprint ability test (RSM) in elite young team handball (TH) players. Participants were members of the Iranian national team (n = 20, age 16.4 ± 0.7 years, weight 82.5 ± 5.5 kg, height 184.8 ± 4.6 cm, body fat 15.4 ± 4.3%). The validity of RSM was tested against a 10 × (15 + 15 m) repeated sprint ability test (RSA), Yo-Yo Intermittent Recovery test Level 1 (Yo-Yo IR1), squat jump (SJ) and countermovement jump (CMJ). To test the reliability of RSM, the participants repeated the testing sessions of RSM and RSA 1 week later. Both RSA and RSM tests showed good to excellent reliability of the total time (TT), best time (BT), and weakest time (WT). The results of the correlation analysis showed significant inverse correlations between maximum aerobic capacity and TT in RSA (r = −0.57, p ≤ 0.05) and RSM (r = −0.76, p ≤ 0.01). There was also a significant inverse correlation between maximum aerobic capacity with fatigue index (FI) in RSA test (r = −0.64, p ≤ 0.01) and in RSM test (r = −0.53, p ≤ 0.05). BT, WT, and TT of RSA was largely-to-very largely correlated with BT (r = 0.58, p ≤ 0.01), WT (r = 0.62, p ≤ 0.01), and TT (r = 0.65, p ≤ 0.01) of RSM. BT in RSM was also correlated with FI in RSM (r = 0.88, p ≤ 0.01). In conclusion, based on the findings of the current study, the recently developed RSM test is a valid and reliable test and should be utilized for assessment of repeated sprint ability in handball players. PMID:29670536

  6. Establishing a 'Physician's Spiritual Well-being Scale' and testing its reliability and validity.

    Science.gov (United States)

    Fang, C K; Li, P Y; Lai, M L; Lin, M H; Bridge, D T; Chen, H W

    2011-01-01

    The purpose of this study was to develop a Physician's Spiritual Well-Being Scale (PSpWBS). The significance of a physician's spiritual well-being was explored through in-depth interviews with and qualitative data collection from focus groups. Based on the results of qualitative analysis and related literature, the PSpWBS consisting of 25 questions was established. Reliability and validity tests were performed on 177 subjects. Four domains of the PSpWBS were devised: physician's characteristics; medical practice challenges; response to changes; and overall well-being. The explainable total variance was 65.65%. Cronbach α was 0.864 when the internal consistency of the whole scale was calculated. Factor analysis showed that the internal consistency Cronbach α value for each factor was between 0.625 and 0.794 and the split-half reliability was 0.865. The scale has satisfactory reliability and validity and could serve as the basis for assessment of the spiritual well-being of a physician.

  7. Test-Retest Reliability of a Serious Game for Delirium Screening in the Emergency Department.

    Science.gov (United States)

    Tong, Tiffany; Chignell, Mark; Tierney, Mary C; Lee, Jacques S

    2016-01-01

    Introduction: Cognitive screening in settings such as emergency departments (ED) is frequently carried out using paper-and-pencil tests that require administration by trained staff. These assessments often compete with other clinical duties and thus may not be routinely administered in these busy settings. Literature has shown that the presence of cognitive impairments such as dementia and delirium are often missed in older ED patients. Failure to recognize delirium can have devastating consequences including increased mortality (Kakuma et al., 2003). Given the demands on emergency staff, an automated cognitive test to screen for delirium onset could be a valuable tool to support delirium prevention and management. In earlier research we examined the concurrent validity of a serious game, and carried out an initial assessment of its potential as a delirium screening tool (Tong et al., 2016). In this paper, we examine the test-retest reliability of the game, as it is an important criterion in a cognitive test for detecting risk of delirium onset. Objective: To demonstrate the test-retest reliability of the screening tool over time in a clinical sample of older emergency patients. A secondary objective is to assess whether there are practice effects that might make game performance unstable over repeated presentations. Materials and Methods: Adults over the age of 70 were recruited from a hospital ED. Each patient played our serious game in an initial session soon after they arrived in the ED, and in follow up sessions conducted at 8-h intervals (for each participant there were up to five follow up sessions, depending on how long the person stayed in the ED). Results: A total of 114 adults (61 females, 53 males) between the ages of 70 and 104 years ( M = 81 years, SD = 7) participated in our study after screening out delirious patients. We observed a test-retest reliability of the serious game (as assessed by correlation r -values) between 0.5 and 0.8 across adjacent

  8. Is the Bayley Scales of Infant and Toddler Developmental Screening Test, Valid and Reliable for Persian Speaking Children?

    Science.gov (United States)

    Soleimani, Farin; Azari, Nadia; Vameghi, Roshanak; Sajedi, Firoozeh; Shahshahani, Soheila; Karimi, Hossein; Kraskian, Adis; Shahrokhi, Amin; Teymouri, Robab; Gharib, Masoud

    2016-10-01

    Advances in perinatal and neonatal care have substantially improved the survival of at-risk infants over the past two decades. The purpose of this study was to assess the reliability and validity of the Bayley Scales of infant and toddler developmental Screening test in Persian-speaking children. This was a cross-sectional prospective study of 403 children aged 1 - 42-months. The Bayley scales screening instrument, which consists of five domains (cognitive, receptive, and expressive communication and fine and gross motor items), was used to measure infants' and toddlers' development. The psychometric properties examined included the face and content validity of the scale, in addition to cultural and linguistic modifications to the scale and its test-retest and inter-rater reliability. An expert team changed some of the test items relating to cultural and linguistic issues. In almost all the age groups, cultural or linguistic changes were made to items in the communication domains. According to Cronbach's alpha for internal consistency, the reliability of the cognitive scale was r = 0.79, and the reliability of the receptive scale was r = 0.76. The reliability for expressive communication, fine motor, and gross motor scales was r = 0.81, r = 0.80, and r = 0.81, respectively. The construct validity of the tests was confirmed using a factor analysis and comparison of the mean scores of the age groups. The intra- and inter-rater reliabilities of the Bayley Scales were good-to-excellent. The results indicated that the Bayley Scales had a high level of reliability in the present study. Thus, the scale can be used in a Persian population.

  9. Test-Retest Reliability and Practice Effects of the Stability Evaluation Test.

    Science.gov (United States)

    Williams, Richelle M; Corvo, Matthew A; Lam, Kenneth C; Williams, Travis A; Gilmer, Lesley K; McLeod, Tamara C Valovich

    2017-01-17

    Postural control plays an essential role in concussion evaluation. The Stability Evaluation Test (SET) aims to objectively analyze postural control by measuring sway velocity on the NeuroCom's VSR portable force platform (Natus, San Carlos, CA). To assess the test-retest reliability and practice effects of the SET protocol. Cohort. Research Laboratory. Fifty healthy adults (males=20, females=30, age=25.30±3.60 years, height=166.60±12.80 cm, mass=68.80±13.90 kg). All participants completed four trials of the SET. Each trial consisted of six 20-second balance tests with eyes closed, under the following conditions: double-leg firm (DFi), single-leg firm (SFi), tandem firm (TFi), double-leg foam (DFo), single-leg foam (SFo), and tandem foam (TFo). Each trial was separated by a 5-minute seated rest period. The dependent variable was sway velocity (deg/sec), with lower values indicating better balance. Sway velocity was recorded for each of the six conditions as well as a composite score for each trial. Test-retest reliability was analyzed across four trials with Intraclass Correlation Coefficients. Practice effects analyzed with repeated measures analysis of variance, followed by Tukey post-hoc comparisons for any significant main effects (preliability values were good to excellent: DFi (ICC=0.88;95%CI:0.81,0.92), SFi (ICC=0.75;95%CI:0.61,0.85), TFi (ICC=0.84;95%CI:0.75,0.90), DFo (ICC=0.83;95%CI:0.74,0.90), SFo (ICC=0.82;95%CI:0.72,0.89), TFo (ICC=0.81;95%CI:0.69,0.88), and composite score (ICC=0.93;95%CI:0.88,0.95). Significant practice effects (preliability for the assessment of postural control in healthy adults. Due to the practice effects noted, a familiarization session is recommended (i.e., all 6 conditions) prior to recording the data. Future studies should evaluate injured patients to determine meaningful change scores during various injuries.

  10. Development, test-retest reliability, and construct validity of the resistance training skills battery.

    Science.gov (United States)

    Lubans, David R; Smith, Jordan J; Harries, Simon K; Barnett, Lisa M; Faigenbaum, Avery D

    2014-05-01

    The aim of this study was to describe the development and assess test-retest reliability and construct validity of the Resistance Training Skills Battery (RTSB) for adolescents. The RTSB provides an assessment of resistance training skill competency and includes 6 exercises (i.e., body weight squat, push-up, lunge, suspended row, standing overhead press, and front support with chest touches). Scoring for each skill is based on the number of performance criteria successfully demonstrated. An overall resistance training skill quotient (RTSQ) is created by adding participants' scores for the 6 skills. Participants (44 boys and 19 girls, mean age = 14.5 ± 1.2 years) completed the RTSB on 2 occasions separated by 7 days. Participants also completed the following fitness tests, which were used to create a muscular fitness score (MFS): handgrip strength, timed push-up, and standing long jump tests. Intraclass correlation (ICC), paired samples t-tests, and typical error were used to assess test-retest reliability. To assess construct validity, gender and RTSQ were entered into a regression model predicting MFS. The rank order repeatability of the RTSQ was high (ICC = 0.88). The model explained 39% of the variance in MFS (p ≤ 0.001) and RTSQ (r = 0.40, p ≤ 0.001) was a significant predictor. This study has demonstrated the construct validity and test-retest reliability of the RTSB in a sample of adolescents. The RTSB can reliably rank participants in regards to their resistance training competency and has the necessary sensitivity to detect small changes in resistance training skill proficiency.

  11. Is gait variability reliable in older adults and Parkinson's disease? Towards an optimal testing protocol.

    Science.gov (United States)

    Galna, Brook; Lord, Sue; Rochester, Lynn

    2013-04-01

    Despite the widespread use of gait variability in research and clinical studies, testing protocols designed to optimise its reliability have not been established. This study evaluates the impact of testing protocol and pathology on the reliability of gait variability. To (i) estimate the reliability of gait variability during continuous and intermittent walking protocols in older adults and people with Parkinson's disease (PD), (ii) determine optimal number of steps for acceptable levels of reliability of gait variability and (iii) provide sample size estimates for use in clinical trials. Gait variability was measured twice, one week apart, in 27 older adults and 25 PD participants. Participants walked at their preferred pace during: (i) a continuous 2 min walk and (ii) 3 intermittent walks over a 12 m walkway. Gait variability was calculated as the within-person standard deviation for step velocity, length and width, and step, stance and swing duration. Reliability of gait variability ranged from poor to excellent (intra class correlations .041-.860; relative limits of agreement 34-89%). Gait variability was more reliable during continuous walks. Control and PD participants demonstrated similar reliability. Increasing the number of steps improved reliability, with most improvement seen across the first 30 steps. In this study, we identified testing protocols that improve the reliability of measuring gait variability. We recommend using a continuous walking protocol and to collect no fewer than 30 steps. Early PD does not appear to impact negatively on the reliability of gait variability. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. The prone bridge test: Performance, validity, and reliability among older and younger adults.

    Science.gov (United States)

    Bohannon, Richard W; Steffl, Michal; Glenney, Susan S; Green, Michelle; Cashwell, Leah; Prajerova, Kveta; Bunn, Jennifer

    2018-04-01

    The prone bridge maneuver, or plank, has been viewed as a potential alternative to curl-ups for assessing trunk muscle performance. The purpose of this study was to assess prone bridge test performance, validity, and reliability among younger and older adults. Sixty younger (20-35 years old) and 60 older (60-79 years old) participants completed this study. Groups were evenly divided by sex. Participants completed surveys regarding physical activity and abdominal exercise participation. Height, weight, body mass index (BMI), and waist circumference were measured. On two occasions, 5-9 days apart, participants held a prone bridge until volitional exhaustion or until repeated technique failure. Validity was examined using data from the first session: convergent validity by calculating correlations between survey responses, anthropometrics, and prone bridge time, known groups validity by using an ANOVA comparing bridge times of younger and older adults and of men and women. Test-retest reliability was examined by using a paired t-test to compare prone bridge times for Session1 and Session 2. Furthermore, an intraclass correlation coefficient (ICC) was used to characterize relative reliability and minimal detectable change (MDC 95% ) was used to describe absolute reliability. The mean prone bridge time was 145.3 ± 71.5 s, and was positively correlated with physical activity participation (p ≤ 0.001) and negatively correlated with BMI and waist circumference (p ≤ 0.003). Younger participants had significantly longer plank times than older participants (p = 0.003). The ICC between testing sessions was 0.915. The prone bridge test is a valid and reliable measure for evaluating abdominal performance in both younger and older adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease

    NARCIS (Netherlands)

    Strouwen, C.; Molenaar, E.A.; Keus, S.H.; Munks, L.; Bloem, B.R.; Nieuwboer, A.

    2016-01-01

    BACKGROUND: Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains

  14. Relative and Absolute Reliability of Timed Up and Go Test in Community Dwelling Older Adult and Healthy Young People

    Directory of Open Access Journals (Sweden)

    Farhad Azadi

    2014-01-01

    Full Text Available Objectives: Relative and absolute reliability are psychometric properties of the test that many clinical decisions are based on them. In many cases, only relative reliability takes into consideration while the absolute reliability is also very important. Methods & Materials: Eleven community-dwelling older adults aged 65 years and older (69.64±3.58 and 20 healthy young in the age range 20 to 35 years (28.80±4.15 using three versions of Timed Up and Go test were evaluated twice with an interval of 2 to 5 days. Results: Generally, the non-homogeneity of the study population was stratified to increase the Intra-class Correlation Coefficient (ICC this coefficient in elderly people is greater than young people and with a secondary task is reduced. In This study, absolute reliability indices using different data sources and equations lead to in more or less similar results. At general, in test–retest situations, the elderly more than the young people must be changed to be interpreted as a real change, not random. The random error contribution is slightly greater in elderly than young and with a secondary task is increased.It seems, heterogeneity leads to moderation in absolute reliability indices. Conclusion: In relative reliability studies, researchers and clinicians should pay attention to factors such as homogeneity of population and etc. As well as, absolute reliability beside relative reliability is needed and necessary in clinical decision making.

  15. The timed "up and go" test : Reliability and validity in persons with unilateral lower limb amputation

    NARCIS (Netherlands)

    Schoppen, Tanneke; Boonstra, Antje; Groothoff, JW; de Vries, J; Goeken, LNH; Eisma, Willem

    Objective: To determine the interrater and interrater reliability and the validity of the Timed "up and go" test as a measure for physical mobility in elderly patients with an amputation of the lower extremity. Design: To test interrater reliability, the test was performed for two observers at

  16. Construct Validity and Test-Retest Reliability of the Climbing Stairs Questionnaire in Lower-Limb Amputees

    NARCIS (Netherlands)

    de Laat, Fred A.; Rommers, Gerardus M.; Geertzen, Jan H.; Roorda, Leo D.

    de Laat FA, Rommers GM, Geertzen JH, Roorda LD. Construct validity and test-retest reliability of the Climbing Stairs Questionnaire in lower-limb amputees. Arch Phys Med Rehabil 2010;91:1396-401. Objective: To investigate the construct validity and test-retest reliability of the Climbing Stairs

  17. Reliable Decentralized Control of Fuzzy Discrete-Event Systems and a Test Algorithm.

    Science.gov (United States)

    Liu, Fuchun; Dziong, Zbigniew

    2013-02-01

    A framework for decentralized control of fuzzy discrete-event systems (FDESs) has been recently presented to guarantee the achievement of a given specification under the joint control of all local fuzzy supervisors. As a continuation, this paper addresses the reliable decentralized control of FDESs in face of possible failures of some local fuzzy supervisors. Roughly speaking, for an FDES equipped with n local fuzzy supervisors, a decentralized supervisor is called k-reliable (1 ≤ k ≤ n) provided that the control performance will not be degraded even when n - k local fuzzy supervisors fail. A necessary and sufficient condition for the existence of k-reliable decentralized supervisors of FDESs is proposed by introducing the notions of M̃uc-controllability and k-reliable coobservability of fuzzy language. In particular, a polynomial-time algorithm to test the k-reliable coobservability is developed by a constructive methodology, which indicates that the existence of k-reliable decentralized supervisors of FDESs can be checked with a polynomial complexity.

  18. Reliability assessment for safety critical systems by statistical random testing

    International Nuclear Information System (INIS)

    Mills, S.E.

    1995-11-01

    In this report we present an overview of reliability assessment for software and focus on some basic aspects of assessing reliability for safety critical systems by statistical random testing. We also discuss possible deviations from some essential assumptions on which the general methodology is based. These deviations appear quite likely in practical applications. We present and discuss possible remedies and adjustments and then undertake applying this methodology to a portion of the SDS1 software. We also indicate shortcomings of the methodology and possible avenues to address to follow to address these problems. (author). 128 refs., 11 tabs., 31 figs

  19. Reliability assessment for safety critical systems by statistical random testing

    Energy Technology Data Exchange (ETDEWEB)

    Mills, S E [Carleton Univ., Ottawa, ON (Canada). Statistical Consulting Centre

    1995-11-01

    In this report we present an overview of reliability assessment for software and focus on some basic aspects of assessing reliability for safety critical systems by statistical random testing. We also discuss possible deviations from some essential assumptions on which the general methodology is based. These deviations appear quite likely in practical applications. We present and discuss possible remedies and adjustments and then undertake applying this methodology to a portion of the SDS1 software. We also indicate shortcomings of the methodology and possible avenues to address to follow to address these problems. (author). 128 refs., 11 tabs., 31 figs.

  20. Reliability and criterion-related validity testing (construct) of the Endotracheal Suction Assessment Tool (ESAT©).

    Science.gov (United States)

    Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne

    2018-05-01

    To establish criterion-related construct validity and test-retest reliability for the Endotracheal Suction Assessment Tool© (ESAT©). Endotracheal tube suction performed in children can significantly affect clinical stability. Previously identified clinical indicators for endotracheal tube suction were used as criteria when designing the ESAT©. Content validity was reported previously. The final stages of psychometric testing are presented. Observational testing was used to measure construct validity and determine whether the ESAT© could guide "inexperienced" paediatric intensive care nurses' decision-making regarding endotracheal tube suction. Test-retest reliability of the ESAT© was performed at two time points. The researchers and paediatric intensive care nurse "experts" developed 10 hypothetical clinical scenarios with predetermined endotracheal tube suction outcomes. "Experienced" (n = 12) and "inexperienced" (n = 14) paediatric intensive care nurses were presented with the scenarios and the ESAT© guiding decision-making about whether to perform endotracheal tube suction for each scenario. Outcomes were compared with those predetermined by the "experts" (n = 9). Test-retest reliability of the ESAT© was measured at two consecutive time points (4 weeks apart) with "experienced" and "inexperienced" paediatric intensive care nurses using the same scenarios and tool to guide decision-making. No differences were observed between endotracheal tube suction decisions made by "experts" (n = 9), "inexperienced" (n = 14) and "experienced" (n = 12) nurses confirming the tool's construct validity. No differences were observed between groups for endotracheal tube suction decisions at T1 and T2. Criterion-related construct validity and test-retest reliability of the ESAT© were demonstrated. Further testing is recommended to confirm reliability in the clinical setting with the "inexperienced" nurse to guide decision-making related to endotracheal tube

  1. Reliability and Validity of a New Test of Change-of-Direction Speed for Field-Based Sports: the Change-of-Direction and Acceleration Test (CODAT).

    Science.gov (United States)

    Lockie, Robert G; Schultz, Adrian B; Callaghan, Samuel J; Jeffriess, Matthew D; Berry, Simon P

    2013-01-01

    Field sport coaches must use reliable and valid tests to assess change-of-direction speed in their athletes. Few tests feature linear sprinting with acute change- of-direction maneuvers. The Change-of-Direction and Acceleration Test (CODAT) was designed to assess field sport change-of-direction speed, and includes a linear 5-meter (m) sprint, 45° and 90° cuts, 3- m sprints to the left and right, and a linear 10-m sprint. This study analyzed the reliability and validity of this test, through comparisons to 20-m sprint (0-5, 0-10, 0-20 m intervals) and Illinois agility run (IAR) performance. Eighteen Australian footballers (age = 23.83 ± 7.04 yrs; height = 1.79 ± 0.06 m; mass = 85.36 ± 13.21 kg) were recruited. Following familiarization, subjects completed the 20-m sprint, CODAT, and IAR in 2 sessions, 48 hours apart. Intra-class correlation coefficients (ICC) assessed relative reliability. Absolute reliability was analyzed through paired samples t-tests (p ≤ 0.05) determining between-session differences. Typical error (TE), coefficient of variation (CV), and differences between the TE and smallest worthwhile change (SWC), also assessed absolute reliability and test usefulness. For the validity analysis, Pearson's correlations (p ≤ 0.05) analyzed between-test relationships. Results showed no between-session differences for any test (p = 0.19-0.86). CODAT time averaged ~6 s, and the ICC and CV equaled 0.84 and 3.0%, respectively. The homogeneous sample of Australian footballers meant that the CODAT's TE (0.19 s) exceeded the usual 0.2 x standard deviation (SD) SWC (0.10 s). However, the CODAT is capable of detecting moderate performance changes (SWC calculated as 0.5 x SD = 0.25 s). There was a near perfect correlation between the CODAT and IAR (r = 0.92), and very large correlations with the 20-m sprint (r = 0.75-0.76), suggesting that the CODAT was a valid change-of-direction speed test. Due to movement specificity, the CODAT has value for field sport

  2. Levodopa responsiveness of dysphagia in advanced Parkinson's disease and reliability testing of the FEES-Levodopa-test.

    Science.gov (United States)

    Warnecke, Tobias; Suttrup, Inga; Schröder, Jens B; Osada, Nani; Oelenberg, Stephan; Hamacher, Christina; Suntrup, Sonja; Dziewas, Rainer

    2016-07-01

    It is still controversially discussed whether central dopaminergic stimulation improves swallowing ability in Parkinson's disease (PD). We evaluated the effect of oral levodopa application on dysphagia in advanced PD patients with motor fluctuations. In 15 PD patients (mean age 71.93 ± 8.29 years, mean disease duration 14.33 ± 5.94 years) with oropharyngeal dysphagia and motor fluctuations endoscopic swallowing evaluation was performed in the off state and on state condition following a specifically developed protocol (FEES-levodopa-test). The respective dysphagia score covered three salient parameters, i. e. premature spillage, penetration/aspiration events and residues, each tested with liquid as well as semisolid and solid food consistencies. An improvement of >30% in this score indicated levodopa responsiveness of dysphagia. Measures were compared between the off- and on-state condition by using the Wilcoxon Test and marginal homogeneity test. Inter- and intrarater reliability was also investigated. Severity of swallowing dysfunction in the off state varied widely. The lowest dysphagia score was 15 points (dysphagia without any aspiration risk). The highest dysphagia score was 84 points (dysphagia with aspiration of all consistencies). Seven patients showed a marked improvement of dysphagia in the on state condition. Eight PD patients did not respond. Inter- and intrarater reliability was excellent for all three subscales in the off state and on state conditions. A significant proportion of advanced PD patients with motor fluctuations and mild to moderate oropharyngeal dysphagia may demonstrate a clinically relevant improvement of swallowing after levodopa challenge. The FEES-levodopa-test is a reliable and sensitive tool to differentiate these responders from non-responders. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Results of the EC research project REQUEST on software quality and reliability

    International Nuclear Information System (INIS)

    Kersken, M.; Saglietti, F.

    1990-01-01

    GRS work in software safety was mainly concerned with the qualitative assessment of software reliability and quality. As a supplement to these activities the work within the REQUEST project emphasized the quantitative determination of the respective parameters. The three-level quality model COQUAMO serves for the computation - and partly for the prediction - of quality factors during the software life cycle. PERFIDE controls the application of software reliability models during the test phase and in early operational life. Specific attention was paid to the assessment of fault-tolerant diverse software systems. (orig.) [de

  4. Interrater reliability assessment using the Test of Gross Motor Development-2.

    Science.gov (United States)

    Barnett, Lisa M; Minto, Christine; Lander, Natalie; Hardy, Louise L

    2014-11-01

    The aim was to examine interrater reliability of the object control subtest from the Test of Gross Motor Development-2 by live observation in a school field setting. Reliability Study--cross sectional. Raters were rated on their ability to agree on (1) the raw total for the six object control skills; (2) each skill performance and (3) the skill components. Agreement for the object control subtest and the individual skills was assessed by an intraclass correlation (ICC) and a kappa statistic assessed for skill component agreement. A total of 37 children (65% girls) aged 4-8 years (M = 6.2, SD = 0.8) were assessed in six skills by two raters; equating to 222 skill tests. Interrater reliability was excellent for the object control subset (ICC = 0.93), and for individual skills, highest for the dribble (ICC = 0.94) followed by strike (ICC = 0.85), overhand throw (ICC = 0.84), underhand roll (ICC = 0.82), kick (ICC = 0.80) and the catch (ICC = 0.71). The strike and the throw had more components with less agreement. Even though the overall subtest score and individual skill agreement was good, some skill components had lower agreement, suggesting these may be more problematic to assess. This may mean some skill components need to be specified differently in order to improve component reliability. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  5. Reliability demonstration test for load-sharing systems with exponential and Weibull components.

    Directory of Open Access Journals (Sweden)

    Jianyu Xu

    Full Text Available Conducting a Reliability Demonstration Test (RDT is a crucial step in production. Products are tested under certain schemes to demonstrate whether their reliability indices reach pre-specified thresholds. Test schemes for RDT have been studied in different situations, e.g., lifetime testing, degradation testing and accelerated testing. Systems designed with several structures are also investigated in many RDT plans. Despite the availability of a range of test plans for different systems, RDT planning for load-sharing systems hasn't yet received the attention it deserves. In this paper, we propose a demonstration method for two specific types of load-sharing systems with components subject to two distributions: exponential and Weibull. Based on the assumptions and interpretations made in several previous works on such load-sharing systems, we set the mean time to failure (MTTF of the total system as the demonstration target. We represent the MTTF as a summation of mean time between successive component failures. Next, we introduce generalized test statistics for both the underlying distributions. Finally, RDT plans for the two types of systems are established on the basis of these test statistics.

  6. An Operators View of Reliability Testing and Decay Heat Rejection Systems

    International Nuclear Information System (INIS)

    Henderson, J.D.C.

    1975-01-01

    The object of this paper is to review the in-situ testing of DHR systems, and to convey policy rather than to indicate a definitive test programme. The test policy is aimed primarily at commissioning the plant and secondly at providing such support for reliability predictions as is practical. Provisions for removal of decay heat from the core and from the reactor tank are described in papers by Broadley and Davies

  7. Test-retest reliability and smallest detectable change of the Bristol Impact of Hypermobility (BIoH) questionnaire.

    Science.gov (United States)

    Palmer, S; Manns, S; Cramp, F; Lewis, R; Clark, E M

    2017-12-01

    The Bristol Impact of Hypermobility (BIoH) questionnaire is a patient-reported outcome measure developed in conjunction with adults with Joint Hypermobility Syndrome (JHS). It has demonstrated strong concurrent validity with the Short Form-36 (SF-36) physical component score but other psychometric properties have yet to be established. This study aimed to determine its test-retest reliability and smallest detectable change (SDC). A test-retest reliability study. Participants were recruited from the Hypermobility Syndromes Association, a patient organisation in the United Kingdom. Recruitment packs were sent to 1080 adults who had given permission to be contacted about research. BIoH and SF-36 questionnaires were administered at baseline and repeated two weeks later. An 11-point global rating of change scale (-5 to +5) was also administered at two weeks. Test-retest analysis and calculation of the SDC was conducted on 'stable' patients (defined as global rating of change -1 to +1). 462 responses were received. 233 patients reported a 'stable' condition and were included in analysis (95% women; mean (SD) age 44.5 (13.9) years; BIoH score 223.6 (54.0)). The BIoH questionnaire demonstrated excellent test-retest reliability (ICC 0.923, 95% CI 0.900-0.940). The SDC was 42 points (equivalent to 19% of the mean baseline score). The SF-36 physical and mental component scores demonstrated poorer test-retest reliability and larger SDCs (as a proportion of the mean baseline scores). The results provide further evidence of the potential of the BIoH questionnaire to underpin research and clinical practice for people with JHS. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Machine Learning Approach for Software Reliability Growth Modeling with Infinite Testing Effort Function

    Directory of Open Access Journals (Sweden)

    Subburaj Ramasamy

    2017-01-01

    Full Text Available Reliability is one of the quantifiable software quality attributes. Software Reliability Growth Models (SRGMs are used to assess the reliability achieved at different times of testing. Traditional time-based SRGMs may not be accurate enough in all situations where test effort varies with time. To overcome this lacuna, test effort was used instead of time in SRGMs. In the past, finite test effort functions were proposed, which may not be realistic as, at infinite testing time, test effort will be infinite. Hence in this paper, we propose an infinite test effort function in conjunction with a classical Nonhomogeneous Poisson Process (NHPP model. We use Artificial Neural Network (ANN for training the proposed model with software failure data. Here it is possible to get a large set of weights for the same model to describe the past failure data equally well. We use machine learning approach to select the appropriate set of weights for the model which will describe both the past and the future data well. We compare the performance of the proposed model with existing model using practical software failure data sets. The proposed log-power TEF based SRGM describes all types of failure data equally well and also improves the accuracy of parameter estimation more than existing TEF and can be used for software release time determination as well.

  9. Reliability of the Balance Evaluation Systems Test (BESTest) and BESTest sections for adults with hemiparesis

    Science.gov (United States)

    Rodrigues, Letícia C.; Marques, Aline P.; Barros, Paula B.; Michaelsen, Stella M.

    2014-01-01

    BACKGROUND: The Balance Evaluation Systems Test (BESTest) was recently created to allow the development of treatments according to the specific balance system affected in each patient. The Brazilian version of the BESTest has not been specifically tested after stroke. OBJECTIVE: To evaluate the intra- and inter-rater reliability and concurrent and convergent validity of the total score of the BESTest and BESTest sections for adults with hemiparesis after stroke. METHOD: The study included 16 subjects (61.1±7.5 years) with chronic hemiparesis (54.5±43.5 months after stroke). The BESTest was administered by two raters in the same week and one of the raters repeated the test after a one-week interval. Intraclass correlation coefficient (ICC) was calculated to assess intra- and interrater reliability. Concurrent validity with the Berg Balance Scale (BBS) and convergent validity with the Activities-specific Balance Confidence scale (ABC-Brazil) were assessed using Pearson's correlation coefficient. RESULTS: Both the BESTest total score (ICC=0.98) and the BESTest sections (ICC between 0.85 and 0.96) have excellent intrarater reliability. Interrater reliability for the total score was excellent (ICC=0.93) and, for the sections, it ranged between 0.71 and 0.94. The correlation coefficient between the BESTest and the BBS and ABC-Brazil were 0.78 and 0.59, respectively. CONCLUSIONS: The Brazilian version of the BESTest demonstrated adequate reliability when measured by sections and could identify what balance system was affected in patients after stroke. Concurrent validity was excellent with the BBS total score and good to excellent with the sections. The total scores but not the sections present adequate convergent validity with the ABC-Brazil. However, other psychometric properties should be further investigated. PMID:25003281

  10. Intra-rater reliability of cervical sensory motor function and cervical reconstruction test in healthy subjects

    Directory of Open Access Journals (Sweden)

    Hatamvand S

    2016-07-01

    Full Text Available Impairment of cervicocephalic and head joint position sense has an important role in the recurrent and chronic of cervicocephalic pain. The various tools are suggested for evaluating the cervicocephalic joint position sense. Although reconstruction of cervical angle is a clinical criterion for measuring the cervicocephalic proprioception, the reliability of this method has not been completely accepted. The purpose of this study was to evaluate intra-rater reliability of cervical sensory motor function and cervical reconstruction test in healthy subjects. twenty four healthy subjects (25.70±6.08 y through simple non-probability sampling participated in this single-group repeatedmeasures reliability study. Participants were asked to relocate the neck, as accurately as possible, after full active cervical flexion, extension and rotation to the left and right sides. Five trials were performed for each movement. Laser pointer was used in head of patient. The distance between zero spot and joint position which patient had been reconstructed, was measured by centimeter. Intra-class correlation Coefficient (ICCs and Pearson's correlation coefficient test was used to determine intra-rater reliability of variables. The results showed that intra-class correlation Coefficient (ICCs values with 95% confidence interval (CI and the standard error of the measurement (SEM were good to excellent agreement for a single investigator between measurement occasions. Intra-class correlation Coefficient (ICCs values were obtained for flexion movement (ICCs:0.75, good, extension movement (ICCs:0.81, very good, right rotation (ICCs:0.64, good and left rotation (ICCs:0.64, good. The cervicocephalic relocation test to neutral head position by laser pointer is a reliable method to measure cervical sensory motor function. Therefore, it can be used for evaluating cervicocephalic proprioception of patient with cervicocephalic pain.

  11. Ten Year Operating Test Results and Post-Test Analysis of a 1/10 Segment Stirling Sodium Heat Pipe, Phase III

    Science.gov (United States)

    Rosenfeld, John, H; Minnerly, Kenneth, G; Dyson, Christopher, M.

    2012-01-01

    High-temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, Stirling cycle heat sources; and with the resurgence of space nuclear power both as reactor heat removal elements and as radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly, long-term materials compatibility is being evaluated through the use of high-temperature life test heat pipes. Thermacore, Inc., has carried out a sodium heat pipe 10-year life test to establish long-term operating reliability. Sodium heat pipes have demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 87,000 hr (10 yr) at nearly 700 C. These life test results have demonstrated the potential for high-temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and post-test analysis of the heat pipe and sodium working fluid are described.

  12. Recumbent Stepper Submaximal Test response is reliable in adults with and without stroke.

    Directory of Open Access Journals (Sweden)

    David R Wilson

    Full Text Available The purpose of the present study was to determine the reliability of the exercise response (predicted peak VO2 using the total body recumbent stepper (TBRS submaximal exercise test in: 1 healthy adults 20-70 years of age and 2 adults participating in inpatient stroke rehabilitation. We hypothesized that the predicted peak VO2 (Visit 1 would have an excellent relationship (r > 0.80 to predicted peak VO2 (Visit 2. We also wanted to test whether the exercise response at Visit 1 and Visit 2 would be significantly different.Healthy adults were recruited from the Kansas City metro area. Stroke participants were recruited during their inpatient rehabilitation stay. Eligible participants completed 2 TBRS submaximal exercise tests between 24 hours and 5 days at similar times of day.A total of 70 participants completed the study. Healthy adults (n = 50 were 36 M, 38.1 ± 10.1 years and stroke participants (n = 20 were 15 M, 62.5 ± 11.8 years of age. The exercise response was reliable for healthy adults (r = 0.980, p<0.01 and stroke participants (r = 0.987, p<0.01 between Visit 1 and Visit 2. Repeated Measures ANOVA showed a significant difference in predicted values between the two visits for healthy adults (47.2 ± 8.4 vs 47.7 ± 8.5 mL∙kg-1∙min-1; p = 0.04 but not for stroke participants (25.0 ± 9.9 vs 25.3 ± 11.4 mL∙kg-1∙min-1; p = 0.65.These results suggest that the exercise response is reliable using the TBRS submaximal exercise test in this cohort of healthy adults and stroke participants.

  13. Reliability and main findings of the FEES-Tensilon Test in patients with myasthenia gravis and dysphagia.

    Science.gov (United States)

    Im, Sun; Suntrup-Krueger, Sonja; Colbow, Sigrid; Sauer, Sonja; Claus, Inga; Meuth, Sven G; Dziewas, Rainer; Warnecke, Tobias

    2018-05-26

    Diagnosis of pharyngeal dysphagia caused by myasthenia gravis (MG) based on clinical examination alone is often challenging. Flexible endoscopic evaluation of swallowing (FEES) combined with Tensilon (edrophonium) application, referred to as the FEES-Tensilon Test, was developed to improve diagnostic accuracy and to detect the main symptoms of pharyngeal dysphagia in MG. Here we investigated inter- and intra-rater reliability of the FEES-Tensilon Test and analyzed the main endoscopic findings. Four experienced raters reviewed a total of 20 FEES-Tensilon-Test videos in randomized order. Residue severity was graded at 4 different pharyngeal spaces before and after Tensilon administration. All interpretations were performed twice per rater, 4 weeks apart (a total of 160 scorings). Intra-rater test-retest reliability and inter-rater reliability levels were calculated. The most frequent FEES findings in MG patients before Tensilon application were prominent residues of semi solids spread all over the hypopharynx in varying locations. The reliability level in the interpretation of the FEES-Tensilon test was excellent regardless of the raters' profession or years of experience with FEES. All 4 raters showed high inter- and intra- reliability levels in interpreting the FEES-Tensilon Test based on residue clearance (kappa=0.922, 0.981). Degree of residue normalization in the vallecular space after Tensilon application showed the highest inter- and intra-rater reliability level (kappa=0.863, 0.957) followed by the epiglottis (kappa=0.813, 0.946) and pyriform sinuses (kappa=0.836, 0.929). Interpretation of the FEES-Tensilon Test based on residue severity and degree of Tensilon clearance, especially in the vallecular space, is consistent and reliable. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  14. Enertech 2-kW high-reliability wind system. Phase II. Fabrication and testing

    Energy Technology Data Exchange (ETDEWEB)

    Cordes, J A; Johnson, B A

    1981-06-01

    A high-reliability wind machine rated for 2 kW in a 9 m/s wind has been developed. Activities are summarized that are centered on the fabrication and testing of prototypes of the wind machine. The test results verified that the wind machine met the power output specification and that the variable-pitch rotor effectively controlled the rotor speed for wind speeds up to 50 mph. Three prototypes of the wind machine were shipped to the Rocky Flats test center in September through November of 1979. Work was also performed to reduce the start-up wind speed. The start-up wind speed to the Enertech facility has been reduced to 4.5 m/s.

  15. New design algorithm and reliability testing of solar powered near ...

    African Journals Online (AJOL)

    New design algorithm and reliability testing of solar powered near-space flight vehicle for defense and security. ... To overcome this problem, we propose a pseudo-satellite system where telecommunication devices are carried on a perpetually flying solar aircraft cruising at stratospheric altitude. Our aircraft will combine ...

  16. Molding compound trends in a denser packaging world: Qualification tests and reliability concerns

    Science.gov (United States)

    Nguyen, L. T.; Lo, R. H. Y.; Chen, A. S.; Belani, J. G.

    1993-12-01

    Molding compound development has traditionally been driven by the memory market, then subsequent applications filter down to other IC technologies such as logic, analog, and ASIC. However, this strategy has changed lately with the introduction of thin packages such as PQFP & TSOP. Rather than targeting a compound for a family of IC such as DRAM or SRAM, compound development efforts are now focused at specific classes of packages. The configurations of these thin packages impose new functional requirements that need to be revisited to provide the optimized combination of properties. The evolution of qualification tests mirrors the advances in epoxy and compounding technologies. From the first standard novolac-based epoxies of the 1970s to the latest 3(sup rd)-generation ultra-low stress materials, longer test times at increasingly harsher environments were achieved. This paper benchmarks the current reliability tests used by the electronic industry, examines those tests that affect and are affected by the molding compounds, discusses the relevance of accelerated testing, and addresses the major reliability issues facing current molding compound development efforts. Six compound-related reliability concerns were selected: moldability, package stresses, package cracking, halogen-induced intermetallic growth at bond pads, moisture-induced corrosion, and interfacial delamination. Causes of each failure type are surveyed and remedies are recommended. Accelerated tests are designed to apply to a limited quantity of devices, bias, or environmental conditions larger than usual ratings, to intensify failure mechanisms that would occur under normal operating conditions. The observed behavior is then extrapolated from the lot to the entire population. Emphasis is on compressing the time necessary to obtain reliability data. This approach has two main drawbacks. With increasingly complex devices, even accelerated tests are expensive. And with new technologies, it becomes

  17. Results of interlaboratory tests regarding TXRF

    International Nuclear Information System (INIS)

    Klockenkaemper, R.; Bohlen, A. von

    2000-01-01

    Interlaboratory or intercomparison tests can be performed for proficiency testing of individual laboratories, for the certification of a special sample material and for the validation of a certain method. We participated in two interlaboratory tests in order to validate total reflection x-ray fluorescence analysis (TXRF). We used our results to evaluate TXRF and to compare it with other competing methods, particularly with respect of precision and accuracy. The first interlaboratory test was organized by IAEA (International Atomic Energy Agency, Vienna, Austria). As a candidate for reference material, a lichen (IAEA-336 Lichen) was distributed among 27 participants. In our laboratory, the powdered biogenic material was digested with nitric acid under high pressure and analyzed by TXRF. - The second interlaboratory test was organized by IRMM (Institute for Reference Materials and Measurements, Geel, Belgium). As a certified test sample with undisclosed values, a sediment (IMEP-14) was delivered to 220 laboratories. We digested the geogenic material again by nitric acid and additionally by hydrofluoric acid and analyzed it by TXRF. - In both test samples, six or eight different trace elements, respectively, were determined by TXRF with a content between 2 and 2000 mg/kg. Calibration was carried out by internal standardization. For that purpose, Ga or Se, respectively, was added as standard element. The measurement uncertainty of TXRF was estimated by the method of error propagation. In our paper we will report on the results of the two interlaboratory tests. It will be shown that TXRF is highly reliable for a correct determination of trace elements in biogenic and geogenic samples. It is competitive with the established methods of trace analyses which were involved in these tests and it is even superior to them in certain aspects. (author)

  18. Test-retest reliability of stride time variability while dual tasking in healthy and demented adults with frontotemporal degeneration

    Directory of Open Access Journals (Sweden)

    Herrmann Francois R

    2011-07-01

    Full Text Available Abstract Background Although test-retest reliability of mean values of spatio-temporal gait parameters has been assessed for reliability while walking alone (i.e., single tasking, little is known about the test-retest reliability of stride time variability (STV while performing an attention demanding-task (i.e., dual tasking. The objective of this study was to examine immediate test-retest reliability of STV while single and dual tasking in cognitively healthy older individuals (CHI and in demented patients with frontotemporal degeneration (FTD. Methods Based on a cross-sectional design, 69 community-dwelling CHI (mean age 75.5 ± 4.3; 43.5% women and 14 demented patients with FTD (mean age 65.7 ± 9.8 years; 6.7% women walked alone (without performing an additional task; i.e., single tasking and while counting backward (CB aloud starting from 50 (i.e., dual tasking. Each subject completed two trials for all the testing conditions. The mean value and the coefficient of variation (CoV of stride time while walking alone and while CB at self-selected walking speed were measured using GAITRite® and SMTEC® footswitch systems. Results ICC of mean value in CHI under both walking conditions were higher than ICC of demented patients with FTD and indicated perfect reliability (ICC > 0.80. Reliability of mean value was better while single tasking than dual tasking in CHI (ICC = 0.96 under single-task and ICC = 0.86 under dual-task, whereas it was the opposite in demented patients (ICC = 0.65 under single-task and ICC = 0.81 under dual-task. ICC of CoV was slight to poor whatever the group of participants and the walking condition (ICC Conclusions The immediate test-retest reliability of the mean value of stride time in single and dual tasking was good in older CHI as well as in demented patients with FTD. In contrast, the variability of stride time was low in both groups of participants.

  19. The Reliability of Quality of Upper Extremity Skills Test in Children with Cerebral Palsy

    Directory of Open Access Journals (Sweden)

    Nazila Akbar-Fahimi

    2012-01-01

    Full Text Available Objective: The aim of this study was to survey the reliability of Intra-rater and Inter-rater with and without video camera assessment in children with spastic cerebral palsy. Materials & Methods: In this cross-sectional study, we validate the Quality of Upper Extremity Skill Test questionnaire. Fifty children with hemiplegia aged 19 to 95 months (mean age 61.31 ± 25.7 month were enrolled in our study using non random available approach. After obtaining parents’ consent, intra-rater assessment was performed in one session and intera rater assessment with camera after 10 days. Then, the third examiner did the reassessment using film observation of 46 children from 50. Spearman correlation for survey the reliability of intra-rater & inter rater with & without video recording assessment & gross motor function classification system 66 for determined functionality of child were used. Results: Intra-rater correlation was 0.774-0.996, Inter-rater correlation was 0.663-0.998 and correlation for video camera assessment was 0.710-0.974 for the first and third evaluation and 0.652-0.938 for second and third evaluation. P value for sub scales and total score was P<0.01. Conclusion: There is a high correlation in Intra rater and inter rater assessment with and without video recording in Quality of Upper Extremity Skill Test in children with cerebral palsy. So that it can be used as a reliable test to evaluate Quality of Upper Extremity Skills in these children.

  20. A flexible latent class approach to estimating test-score reliability

    NARCIS (Netherlands)

    van der Palm, D.W.; van der Ark, L.A.; Sijtsma, K.

    2014-01-01

    The latent class reliability coefficient (LCRC) is improved by using the divisive latent class model instead of the unrestricted latent class model. This results in the divisive latent class reliability coefficient (DLCRC), which unlike LCRC avoids making subjective decisions about the best solution

  1. Test-retest reliability and sensitivity of the 20-meter walk test among patients with knee osteoarthritis.

    Science.gov (United States)

    Motyl, Jillian M; Driban, Jeffrey B; McAdams, Erica; Price, Lori Lyn; McAlindon, Timothy E

    2013-05-10

    The 20-meter walk test is a physical function measure commonly used in clinical research studies and rehabilitation clinics to measure gait speed and monitor changes in patients' physical function over time. Unfortunately, the reliability and sensitivity of this walk test are not well defined and, therefore, limit our ability to evaluate real changes in gait speed not attributable to normal variability. The aim of this study was to assess the test-restest reliability and sensitivity of the 20-meter walk test, at a self-selected pace, among patients with mild to moderate knee osteoarthritis (OA) and to suggest a standardized protocol for future test administration. This was a measurement reliability study. Fifteen consecutive people enrolled in a randomized-controlled trial of intra-articular corticosteroid injections for knee OA participated in this study. All participants completed 4 trials on 2 separate days, 7 to 21 days apart (8 trials total). Each day was divided into 2 sessions, which each involved 2 walking trials. We compared walk times between trials with Wilcoxon signed-rank tests. Similar analyses compared average walk times between sessions. To confirm these analyses, we also calculated Spearman correlation coefficients to assess the relationship between sessions. Finally, smallest detectable differences (SDD) were calculated to estimate the sensitivity of the 20-meter walk test. Wilcoxon signed-rank tests between trials within the same session demonstrated that trials in session 1 were significantly different and in the subsequent 3 sessions, the median differences between trials were not significantly different. Therefore, the first session of each day was considered a practice session, and the SDD between the second session of each day were calculated. SDD was -1.59 seconds (walking slower) and 0.15 seconds (walking faster). Practice trials and a standardized protocol should be used in administration of the 20-meter walk test. Changes in walk time

  2. Reliability analysis of structures under periodic proof tests in service

    Science.gov (United States)

    Yang, J.-N.

    1976-01-01

    A reliability analysis of structures subjected to random service loads and periodic proof tests treats gust loads and maneuver loads as random processes. Crack initiation, crack propagation, and strength degradation are treated as the fatigue process. The time to fatigue crack initiation and ultimate strength are random variables. Residual strength decreases during crack propagation, so that failure rate increases with time. When a structure fails under periodic proof testing, a new structure is built and proof-tested. The probability of structural failure in service is derived from treatment of all the random variables, strength degradations, service loads, proof tests, and the renewal of failed structures. Some numerical examples are worked out.

  3. Feasibility and reliability of physical fitness tests in older adults with intellectual disability : A pilot study

    NARCIS (Netherlands)

    Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    Background Physical fitness is relevant for wellbeing and health, but knowledge on the feasibility and reliability of instruments to measure physical fitness for older adults with intellectual disability is lacking. Methods Feasibility and test-retest reliability of a physical fitness test battery

  4. Reliability and Usefulness of the 30-15 Intermittent Fitness Test in Male and Female Professional Futsal Players

    Directory of Open Access Journals (Sweden)

    Valladares-Rodríguez Santiago

    2017-12-01

    Full Text Available The purpose of this study was to determine the reliability and usefulness of the 30-15 Intermittent Fitness Test (30-15IFT in professional male and female futsal players. Thirteen male (24.4 ± 5.6 years; 174.5 ± 10.3 cm; 70.3 ± 9.9 kg and fourteen female (23.3 ± 4.5 years; 165.8 ± 6.2 cm; 61.7 ± 5.5 kg professional futsal players performed the 30-15IFT on two occasions, separated by 5 days. Maximal intermittent running velocity (VIFT and heart rate at exhaustion (HRpeak data were collected for both tests. Reliability was assessed by the intraclass correlation coefficient (ICC, typical error (TE expressed as a coefficient of variation (CV, and smallest worthwhile change (SWC. VIFT demonstrated very good reliability between sessions, both for male (ICC = 0.92 and female (ICC = 0.96 players. As the TE for VIFT and HRpeak was similar to the calculated SWC for both male and female players, the usefulness of the test was rated as “medium”. A change in performance of at least 2 stages in male players, or a change of more than 1 stage in female players could be interpreted as a meaningful change in aerobic futsal fitness. The results of this study demonstrate that the 30-15IFT is both a reliable and useful test for male and female professional futsal players.

  5. Reliability of 4-meter and 10-meter walk tests after lower extremity surgery.

    Science.gov (United States)

    Unver, Bayram; Baris, Refik Hilmi; Yuksel, Ertugrul; Cekmece, Senol; Kalkan, Serpil; Karatosun, Vasfi

    2017-12-01

    To investigate the test-retest reliability of the 4-meter walk test (4 MWT) and 10-meter walk test (10 MWT) in patients undergoing lower extremity surgery during inpatient rehabilitation. In all, 102 patients with total hip arthroplasty (THA), total knee arthroplasty (TKA), lower extremity fracture (LEF) and soft tissue operation were recruited. Patients performed two 4 MWT and two 10 MWT trials on the same day. The same researcher performed all the measurements to avoid inter-rater variability. The 4 MWT and 10 MWT were shown to have excellent test-retest reliability. The ICCs for the 4 MWT and 10 MWT were found as 0.94 and 0.95, respectively. The SEMs for the 4 MWT and 10 MWT were 2.0 and 5.5 seconds, respectively. The smallest real difference at the 95% confidence level (SRD95) was 5.5 seconds for the 4 MWT and 12.2 seconds for 10 MWT and SRD95 percentage was 31.2 for the 4 MWT and 28.5 for the 10 MWT. Both the 4 MWT and the 10 MWT have excellent reliability in patients undergoing lower extremity surgery such as TKA, THA, LEF and soft tissue operation during inpatient rehabilitation. Clinicians and researchers can be confident that changes above the SRD95s for the different patient groups, for both sexes and with regard to weight-bearing status, represent a real clinical change in rehabilitation process. Implications for Rehabilitation The 4 MWT and the 10 MWT are simple methods and were also shown to be reliable measurement methods in many patient groups. This study illustrates that the test-retest reliability of the 4 MWT and 10 MWT are excellent in patients undergoing lower extremity surgery during inpatient rehabilitation (ICC: 0.94 for 4 MWT, ICC: 0.95 for 10 MWT). Clinicians and researchers can be confident that changes above the SRD95s for the different patient groups, for both sexes and with regard to weight-bearing status represent a real clinical change in rehabilitation process.

  6. On the Reliability of Implicit and Explicit Memory Measures.

    Science.gov (United States)

    Buchner, Axel; Wippich, Werner

    2000-01-01

    Studied the reliability of implicit and explicit memory tests in experiments involving these tests. Results with 168, 84, 120, and 128 undergraduates show that methodological artifacts may cause implicit memory tests to have lower reliability than explicit memory tests, but that implicit tests need not necessarily be less reliable. (SLD)

  7. Study of Optimal Perimetric Testing in Children (OPTIC: Feasibility, Reliability and Repeatability of Perimetry in Children.

    Directory of Open Access Journals (Sweden)

    Dipesh E Patel

    Full Text Available To investigate feasibility, reliability and repeatability of perimetry in children.A prospective, observational study recruiting 154 children aged 5-15 years, without an ophthalmic condition that affects the visual field (controls, identified consecutively between May 2012 and November 2013 from hospital eye clinics. Perimetry was undertaken in a single sitting, with standardised protocols, in a randomised order using the Humphrey static (SITA 24-2 FAST, Goldmann and Octopus kinetic perimeters. Data collected included test duration, subjective experience and test quality (incorporating examiner ratings on comprehension of instructions, fatigue, response to visual and auditory stimuli, concentration and co-operation to assess feasibility and reliability. Testing was repeated within 6 months to assess repeatability.Overall feasibility was very high (Goldmann=96.1%, Octopus=89% and Humphrey=100% completed the tests. Examiner rated reliability was 'good' in 125 (81.2% children for Goldmann, 100 (64.9% for Octopus and 98 (63.6% for Humphrey perimetry. Goldmann perimetry was the most reliable method in children under 9 years of age. Reliability improved with increasing age (multinomial logistic regression (Goldmann, Octopus and Humphrey, p<0.001. No significant differences were found for any of the three test strategies when examining initial and follow-up data outputs (Bland-Altman plots, n=43, suggesting good test repeatability, although the sample size may preclude detection of a small learning effect.Feasibility and reliability of formal perimetry in children improves with age. By the age of 9 years, all the strategies used here were highly feasible and reliable. Clinical assessment of the visual field is achievable in children as young as 5 years, and should be considered where visual field loss is suspected. Since Goldmann perimetry is the most effective strategy in children aged 5-8 years and this perimeter is no longer available, further

  8. Validation and Reliability of a Novel Test of Upper Body Isometric Strength.

    Science.gov (United States)

    Bellar, David; Marcus, Lena; Judge, Lawrence W

    2015-09-29

    The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4%) volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a "push-up" style position while tethered (stainless steel chain) to a load cell (high frequency) anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98) suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001) with all predictor variables attaining significance in the model (pIsometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001). Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment.

  9. Comprehension of Written Grammar Test: Reliability and Known-Groups Validity Study With Hearing and Deaf and Hard-of-Hearing Students.

    Science.gov (United States)

    Cannon, Joanna E; Hubley, Anita M; Millhoff, Courtney; Mazlouman, Shahla

    2016-01-01

    The aim of the current study was to gather validation evidence for the Comprehension of Written Grammar (CWG; Easterbrooks, 2010) receptive test of 26 grammatical structures of English print for use with children who are deaf and hard of hearing (DHH). Reliability and validity data were collected for 98 participants (49 DHH and 49 hearing) in Grades 2-6. The objectives were to: (a) examine 4-week test-retest reliability data; and (b) provide evidence of known-groups validity by examining expected differences between the groups on the CWG vocabulary pretest and main test, as well as selected structures. Results indicated excellent test-retest reliability estimates for CWG test scores. DHH participants performed statistically significantly lower on the CWG vocabulary pretest and main test than the hearing participants. Significantly lower performance by DHH participants on most expected grammatical structures (e.g., basic sentence patterns, auxiliary "be" singular/plural forms, tense, comparatives, and complementation) also provided known groups evidence. Overall, the findings of this study showed strong evidence of the reliability of scores and known group-based validity of inferences made from the CWG. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Reliability and validity of the new Tanaka B Intelligence Scale scores: a group intelligence test.

    Directory of Open Access Journals (Sweden)

    Yota Uno

    Full Text Available OBJECTIVE: The present study evaluated the reliability and concurrent validity of the new Tanaka B Intelligence Scale, which is an intelligence test that can be administered on groups within a short period of time. METHODS: The new Tanaka B Intelligence Scale and Wechsler Intelligence Scale for Children-Third Edition were administered to 81 subjects (mean age ± SD 15.2 ± 0.7 years residing in a juvenile detention home; reliability was assessed using Cronbach's alpha coefficient, and concurrent validity was assessed using the one-way analysis of variance intraclass correlation coefficient. Moreover, receiver operating characteristic analysis for screening for individuals who have a deficit in intellectual function (an FIQ<70 was performed. In addition, stratum-specific likelihood ratios for detection of intellectual disability were calculated. RESULTS: The Cronbach's alpha for the new Tanaka B Intelligence Scale IQ (BIQ was 0.86, and the intraclass correlation coefficient with FIQ was 0.83. Receiver operating characteristic analysis demonstrated an area under the curve of 0.89 (95% CI: 0.85-0.96. In addition, the stratum-specific likelihood ratio for the BIQ≤65 stratum was 13.8 (95% CI: 3.9-48.9, and the stratum-specific likelihood ratio for the BIQ≥76 stratum was 0.1 (95% CI: 0.03-0.4. Thus, intellectual disability could be ruled out or determined. CONCLUSION: The present results demonstrated that the new Tanaka B Intelligence Scale score had high reliability and concurrent validity with the Wechsler Intelligence Scale for Children-Third Edition score. Moreover, the post-test probability for the BIQ could be calculated when screening for individuals who have a deficit in intellectual function. The new Tanaka B Intelligence Test is convenient and can be administered within a variety of settings. This enables evaluation of intellectual development even in settings where performing intelligence tests have previously been difficult.

  11. Meeting Human Reliability Requirements through Human Factors Design, Testing, and Modeling

    Energy Technology Data Exchange (ETDEWEB)

    R. L. Boring

    2007-06-01

    In the design of novel systems, it is important for the human factors engineer to work in parallel with the human reliability analyst to arrive at the safest achievable design that meets design team safety goals and certification or regulatory requirements. This paper introduces the System Development Safety Triptych, a checklist of considerations for the interplay of human factors and human reliability through design, testing, and modeling in product development. This paper also explores three phases of safe system development, corresponding to the conception, design, and implementation of a system.

  12. Boeing's STAR-FODB test results

    Science.gov (United States)

    Fritz, Martin E.; de la Chapelle, Michael; Van Ausdal, Arthur W.

    1995-05-01

    Boeing has successfully concluded a 2 1/2 year, two phase developmental contract for the STAR-Fiber Optic Data Bus (FODB) that is intended for future space-based applications. The first phase included system analysis, trade studies, behavior modeling, and architecture and protocal selection. During this phase we selected AS4074 Linear Token Passing Bus (LTPB) protocol operating at 200 Mbps, along with the passive, star-coupled fiber media. The second phase involved design, build, integration, and performance and environmental test of brassboard hardware. The resulting brassboard hardware successfully passed performance testing, providing 200 Mbps operation with a 32 X 32 star-coupled medium. This hardware is suitable for a spaceflight experiment to validate ground testing and analysis and to demonstrate performace in the intended environment. The fiber bus interface unit (FBIU) is a multichip module containing transceiver, protocol, and data formatting chips, buffer memory, and a station management controller. The FBIU has been designed for low power, high reliability, and radiation tolerance. Nine FBIUs were built and integrated with the fiber optic physical layer consisting of the fiber cable plant (FCP) and star coupler assembly (SCA). Performance and environmental testing, including radiation exposure, was performed on selected FBIUs and the physical layer. The integrated system was demonstrated with a full motion color video image transfer across the bus while simultaneously performing utility functions with a fiber bus control module (FBCM) over a telemetry and control (T&C) bus, in this case AS1773.

  13. Intra-observer and interobserver reliability ofOne Leg Stand Test as a measure of posturalbalance in low back pain patients

    DEFF Research Database (Denmark)

    Maribo, Thomas; Iversen, Elena; Andersen, Niels Trolle

    2009-01-01

    Objective: To determine the absolute and relative reliability of intra-observer and interobserver To determine the absolute and relative reliability of intra-observer and interobserver measurements of postural balance using the One Leg Stand Test in patients with low back pain. Patients and methods...... to stand for the maximum time, and no further analysis was done. Eyes closed: intra-observer reliability was tested in 21 patients; absolute reliability showed a standard error of the measurement (SEM) of 2.48 s and a minimal detectable change (MDC) of 6.88. The relative reliability was acceptable...... with an intra class correlation coefficient (ICC) of 0.86. Interobserver reliability was tested in 27 patients; absolute reliability showed a SEM of 1.42 s and a MDC of 3.95. The relative reliability was acceptable with an ICC of 0.91. Conclusions: The One Leg Stand Test can be used to test postural balance...

  14. Publishing nutrition research: validity, reliability, and diagnostic test assessment in nutrition-related research.

    Science.gov (United States)

    Gleason, Philip M; Harris, Jeffrey; Sheean, Patricia M; Boushey, Carol J; Bruemmer, Barbara

    2010-03-01

    This is the sixth in a series of monographs on research design and analysis. The purpose of this article is to describe and discuss several concepts related to the measurement of nutrition-related characteristics and outcomes, including validity, reliability, and diagnostic tests. The article reviews the methodologic issues related to capturing the various aspects of a given nutrition measure's reliability, including test-retest, inter-item, and interobserver or inter-rater reliability. Similarly, it covers content validity, indicators of absolute vs relative validity, and internal vs external validity. With respect to diagnostic assessment, the article summarizes the concepts of sensitivity and specificity. The hope is that dietetics practitioners will be able to both use high-quality measures of nutrition concepts in their research and recognize these measures in research completed by others. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  15. Test-retest reliability of the 20-sec Wingate test to assess anaerobic power in children with cerebral palsy

    NARCIS (Netherlands)

    Dallmeijer, A.J.; Scholtes, V.A.B.; Brehm, M.A.; Becher, J.G.

    2013-01-01

    OBJECTIVE: The aim of this study was to determine the test-retest reliability of the 20-sec Wingate anaerobic test in children with cerebral palsy. DESIGN: Participants were 22 ambulant children with cerebral palsy, with Gross Motor Function Classification System levels I (limitations in advanced

  16. Test-Retest Reliability of the 20-sec Wingate Test to Assess Anaerobic Power in Children with Cerebral Palsy

    NARCIS (Netherlands)

    Dallmeijer, Annet J.; Scholtes, Vanessa A. B.; Brehm, Merel-Anne; Becher, Jules G.

    2013-01-01

    Objective: The aim of this study was to determine the test-retest reliability of the 20-sec Wingate anaerobic test in children with cerebral palsy. Design: Participants were 22 ambulant children with cerebral palsy, with Gross Motor Function Classification System levels I (limitations in advanced

  17. Reliability of the Swedish version of the Exercise Self-Efficacy Scale (S-ESES): a test-retest study in adults with neurological disease.

    Science.gov (United States)

    Ahlström, Isabell; Hellström, Karin; Emtner, Margareta; Anens, Elisabeth

    2015-03-01

    To examine the test-retest reliability of the Swedish translated version of the Exercise Self-Efficacy Scale (S-ESES) in people with neurological disease and to examine internal consistency. Test-retest study. A total of 30 adults with neurological diseases including: Parkinson's disease; Multiple Sclerosis; Cervical Dystonia; and Charcot-Marie-Tooth disease. The S-ESES was sent twice by surface mail. Completion interval mean was 16 days apart. Weighted kappa, intraclass correlation coefficient 2,1 [ICC (2,1)], standard error of measurement (SEM), also expressed as a percentage value (SEM%), and Cronbach's alpha were calculated. The relative reliability of the test-retest results showed substantial agreement measured using weighted kappa (MD = 0.62) and a very high-reliability ICC (2,1) (0.92). Absolute reliability measured using SEM was 5.3 and SEM% was 20.7. Excellent internal consistency was shown, with an alpha coefficient of 0.91 (test 1) and 0.93 (test 2). The S-ESES is recommended for use in research and in clinical work for people with neurological diseases. The low-absolute reliability, however, indicates a limited ability to measure changes on an individual level.

  18. Attentional and visual demands for sprint performance in non-fatigued and fatigued conditions: reliability of a repeated sprint test

    Directory of Open Access Journals (Sweden)

    Diercks Ron L

    2010-05-01

    Full Text Available Abstract Background Physical performance measures are widely used to assess physical function, providing information about physiological and biomechanical aspects of motor performance. However they do not provide insight into the attentional and visual demands for motor performance. A figure-of-eight sprint test was therefore developed to measure the attentional and visual demands for repeated-sprint performance. The aims of the study were: 1 to assess test-retest reliability of the figure-of-eight sprint test, and 2 to study the attentional and visual demands for sprint performance in a non-fatigued and fatigued condition. Methods Twenty-seven healthy athletes were included in the study. To determine test-retest reliability, a subgroup of 19 athletes performed the figure-of-eight sprint test twice. The figure-of-eight sprint test consisted of nine 30-second sprints. The sprint test consisted of three test parts: sprinting without any restriction, with an attention-demanding task, and with restricted vision. Increases in sprint times with the attention-demanding task or restricted vision are reflective of the attentional and visual demands for sprinting. Intraclass correlation coefficients (ICCs and mean difference between test and retest with 95% confidence limits (CL were used to assess test-retest reliability. Repeated-measures ANOVA were used for comparisons between the sprint times and fatigue measurements of the test parts in both a non-fatigued and fatigued condition. Results The figure-of-eight sprint test showed good test-retest reliability, with ICCs ranging from 0.75 to 0.94 (95% CL: 0.40-0.98. Zero lay within the 95% CL of the mean differences, indicating that no bias existed between sprint performance at test and retest. Sprint times during the test parts with attention-demanding task (P = 0.01 and restricted vision (P Conclusions High ICCs and the absence of systematic variation indicate good test-retest reliability of the figure

  19. Reliability of Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory in a test-retest design.

    Science.gov (United States)

    Larson, Tomas; Kerekes, Nóra; Selinus, Eva Norén; Lichtenstein, Paul; Gumpert, Clara Hellner; Anckarsäter, Henrik; Nilsson, Thomas; Lundström, Sebastian

    2014-02-01

    The Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory is used in epidemiological research to assess neurodevelopmental problems and coexisting conditions. Although the A-TAC has been applied in various populations, data on retest reliability are limited. The objective of the present study was to present additional reliability data. The A-TAC was administered by lay assessors and was completed on two occasions by parents of 400 individual twins, with an average interval of 70 days between test sessions. Intra- and inter-rater reliability were analysed with intraclass correlations and Cohen's kappa. A-TAC showed excellent test-retest intraclass correlations for both autism spectrum disorder and attention deficit hyperactivity disorder (each at .84). Most modules in the A-TAC had intra- and inter-rater reliability intraclass correlation coefficients of > or = .60. Cohen's kappa indi- cated acceptable reliability. The current study provides statistical evidence that the A-TAC yields good test-retest reliability in a population-based cohort of children.

  20. Reliability engineering

    International Nuclear Information System (INIS)

    Lee, Chi Woo; Kim, Sun Jin; Lee, Seung Woo; Jeong, Sang Yeong

    1993-08-01

    This book start what is reliability? such as origin of reliability problems, definition of reliability and reliability and use of reliability. It also deals with probability and calculation of reliability, reliability function and failure rate, probability distribution of reliability, assumption of MTBF, process of probability distribution, down time, maintainability and availability, break down maintenance and preventive maintenance design of reliability, design of reliability for prediction and statistics, reliability test, reliability data and design and management of reliability.

  1. Pitfalls and important issues in testing reliability using intraclass correlation coefficients in orthopaedic research.

    Science.gov (United States)

    Lee, Kyoung Min; Lee, Jaebong; Chung, Chin Youb; Ahn, Soyeon; Sung, Ki Hyuk; Kim, Tae Won; Lee, Hui Jong; Park, Moon Seok

    2012-06-01

    Intra-class correlation coefficients (ICCs) provide a statistical means of testing the reliability. However, their interpretation is not well documented in the orthopedic field. The purpose of this study was to investigate the use of ICCs in the orthopedic literature and to demonstrate pitfalls regarding their use. First, orthopedic articles that used ICCs were retrieved from the Pubmed database, and journal demography, ICC models and concurrent statistics used were evaluated. Second, reliability test was performed on three common physical examinations in cerebral palsy, namely, the Thomas test, the Staheli test, and popliteal angle measurement. Thirty patients were assessed by three orthopedic surgeons to explore the statistical methods testing reliability. Third, the factors affecting the ICC values were examined by simulating the data sets based on the physical examination data where the ranges, slopes, and interobserver variability were modified. Of the 92 orthopedic articles identified, 58 articles (63%) did not clarify the ICC model used, and only 5 articles (5%) described all models, types, and measures. In reliability testing, although the popliteal angle showed a larger mean absolute difference than the Thomas test and the Staheli test, the ICC of popliteal angle was higher, which was believed to be contrary to the context of measurement. In addition, the ICC values were affected by the model, type, and measures used. In simulated data sets, the ICC showed higher values when the range of data sets were larger, the slopes of the data sets were parallel, and the interobserver variability was smaller. Care should be taken when interpreting the absolute ICC values, i.e., a higher ICC does not necessarily mean less variability because the ICC values can also be affected by various factors. The authors recommend that researchers clarify ICC models used and ICC values are interpreted in the context of measurement.

  2. Reliability of a functional test battery evaluating functionality, proprioception, and strength in recreational athletes with functional ankle instability.

    Science.gov (United States)

    Sekir, U; Yildiz, Y; Hazneci, B; Ors, F; Saka, T; Aydin, T

    2008-12-01

    In contrast to the single evaluation methods used in the past, the combination of multiple tests allows one to obtain a global assessment of the ankle joint. The aim of this study was to determine the reliability of the different tests in a functional test battery. Twenty-four male recreational athletes with unilateral functional ankle instability (FAI) were recruited for this study. One component of the test battery included five different functional ability tests. These tests included a single limb hopping course, single-legged and triple-legged hop for distance, and six and cross six meter hop for time. The ankle joint position sense and one leg standing test were used for evaluation of proprioception and sensorimotor control. The isokinetic strengths of the ankle invertor and evertor muscles were evaluated at a velocity of 120 degrees /s. The reliability of the test battery was assessed by calculating the intraclass correlation coefficient (ICC). Each subject was tested two times, with an interval of 3-5 days between the test sessions. The ICCs for ankle functional and proprioceptive ability showed high reliability (ICCs ranging from 0.94 to 0.98). Additionally, isokinetic ankle joint inversion and eversion strength measurements represented good to high reliability (ICCs between 0.82 and 0.98). The functional test battery investigated in this study proved to be a reliable tool for the assessment of athletes with functional ankle instability. Therefore, clinicians may obtain reliable information from the functional test battery during the assessment of ankle joint performance in patients with functional ankle instability.

  3. Test-retest reliability of selected items of Health Behaviour in School-aged Children (HBSC survey questionnaire in Beijing, China

    Directory of Open Access Journals (Sweden)

    Liu Yang

    2010-08-01

    Full Text Available Abstract Background Children's health and health behaviour are essential for their development and it is important to obtain abundant and accurate information to understand young people's health and health behaviour. The Health Behaviour in School-aged Children (HBSC study is among the first large-scale international surveys on adolescent health through self-report questionnaires. So far, more than 40 countries in Europe and North America have been involved in the HBSC study. The purpose of this study is to assess the test-retest reliability of selected items in the Chinese version of the HBSC survey questionnaire in a sample of adolescents in Beijing, China. Methods A sample of 95 male and female students aged 11 or 15 years old participated in a test and retest with a three weeks interval. Student Identity numbers of respondents were utilized to permit matching of test-retest questionnaires. 23 items concerning physical activity, sedentary behaviour, sleep and substance use were evaluated by using the percentage of response shifts and the single measure Intraclass Correlation Coefficients (ICC with 95% confidence interval (CI for all respondents and stratified by gender and age. Items on substance use were only evaluated for school children aged 15 years old. Results The percentage of no response shift between test and retest varied from 32% for the item on computer use at weekends to 92% for the three items on smoking. Of all the 23 items evaluated, 6 items (26% showed a moderate reliability, 12 items (52% displayed a substantial reliability and 4 items (17% indicated almost perfect reliability. No gender and age group difference of the test-retest reliability was found except for a few items on sedentary behaviour. Conclusions The overall findings of this study suggest that most selected indicators in the HBSC survey questionnaire have satisfactory test-retest reliability for the students in Beijing. Further test-retest studies in a large

  4. Development, construct validity and test-retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball

    NARCIS (Netherlands)

    de Witte, Annemarie M. H.; Hoozemans, Marco J. M.; Berger, Monique A. M.; van der Slikke, Rienk M. A.; van der Woude, Lucas H. V.; Veeger, Dirkjan (H. E. J)

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of

  5. A Systematic Review of the Reliability and Validity of Behavioural Tests Used to Assess Behavioural Characteristics Important in Working Dogs.

    Science.gov (United States)

    Brady, Karen; Cracknell, Nina; Zulch, Helen; Mills, Daniel Simon

    2018-01-01

    Working dogs are selected based on predictions from tests that they will be able to perform specific tasks in often challenging environments. However, withdrawal from service in working dogs is still a big problem, bringing into question the reliability of the selection tests used to make these predictions. A systematic review was undertaken aimed at bringing together available information on the reliability and predictive validity of the assessment of behavioural characteristics used with working dogs to establish the quality of selection tests currently available for use to predict success in working dogs. The search procedures resulted in 16 papers meeting the criteria for inclusion. A large range of behaviour tests and parameters were used in the identified papers, and so behaviour tests and their underpinning constructs were grouped on the basis of their relationship with positive core affect (willingness to work, human-directed social behaviour, object-directed play tendencies) and negative core affect (human-directed aggression, approach withdrawal tendencies, sensitivity to aversives). We then examined the papers for reports of inter-rater reliability, within-session intra-rater reliability, test-retest validity and predictive validity. The review revealed a widespread lack of information relating to the reliability and validity of measures to assess behaviour and inconsistencies in terminologies, study parameters and indices of success. There is a need to standardise the reporting of these aspects of behavioural tests in order to improve the knowledge base of what characteristics are predictive of optimal performance in working dog roles, improving selection processes and reducing working dog redundancy. We suggest the use of a framework based on explaining the direct or indirect relationship of the test with core affect.

  6. The reliability of knee joint position testing using electrogoniometry

    Directory of Open Access Journals (Sweden)

    Winter Adele

    2008-01-01

    Full Text Available Abstract Background The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric® electrogoniometer. The clinical utility of electrogoniometry was also addressed. Methods The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers. Results In the first study, inter-tester reliability (ICC[2,10] ranged from 0.58–0.71 in supine, 0.68–0.79 in sitting and 0.57–0.80 in standing. The standard error of measurement between testers was less than 3.55° and the limits of agreement ranged from -12.51° to 12.21°. Reliability coefficients for intra-tester reliability (ICC[3,10] ranged from 0.75–0.76 in supine, 0.86–0.87 in sitting and 0.87–0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7° and the limits of agreement ranged from -8.13° to 7.90°. The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5°. Conclusion Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer.

  7. Test-retest reliability and construct validity of the ENERGY-child questionnaire on energy balance-related behaviours and their potential determinants: the ENERGY-project

    Directory of Open Access Journals (Sweden)

    Singh Amika S

    2011-12-01

    Full Text Available Abstract Background Insight in children's energy balance-related behaviours (EBRBs and their determinants is important to inform obesity prevention research. Therefore, reliable and valid tools to measure these variables in large-scale population research are needed. Objective To examine the test-retest reliability and construct validity of the child questionnaire used in the ENERGY-project, measuring EBRBs and their potential determinants among 10-12 year old children. Methods We collected data among 10-12 year old children (n = 730 in the test-retest reliability study; n = 96 in the construct validity study in six European countries, i.e. Belgium, Greece, Hungary, the Netherlands, Norway, and Spain. Test-retest reliability was assessed using the intra-class correlation coefficient (ICC and percentage agreement comparing scores from two measurements, administered one week apart. To assess construct validity, the agreement between questionnaire responses and a subsequent face-to-face interview was assessed using ICC and percentage agreement. Results Of the 150 questionnaire items, 115 (77% showed good to excellent test-retest reliability as indicated by ICCs > .60 or percentage agreement ≥ 75%. Test-retest reliability was moderate for 34 items (23% and poor for one item. Construct validity appeared to be good to excellent for 70 (47% of the 150 items, as indicated by ICCs > .60 or percentage agreement ≥ 75%. From the other 80 items, construct validity was moderate for 39 (26% and poor for 41 items (27%. Conclusions Our results demonstrate that the ENERGY-child questionnaire, assessing EBRBs of the child as well as personal, family, and school-environmental determinants related to these EBRBs, has good test-retest reliability and moderate to good construct validity for the large majority of items.

  8. Test-retest reliability and construct validity of the ENERGY-child questionnaire on energy balance-related behaviours and their potential determinants: the ENERGY-project

    Science.gov (United States)

    2011-01-01

    Background Insight in children's energy balance-related behaviours (EBRBs) and their determinants is important to inform obesity prevention research. Therefore, reliable and valid tools to measure these variables in large-scale population research are needed. Objective To examine the test-retest reliability and construct validity of the child questionnaire used in the ENERGY-project, measuring EBRBs and their potential determinants among 10-12 year old children. Methods We collected data among 10-12 year old children (n = 730 in the test-retest reliability study; n = 96 in the construct validity study) in six European countries, i.e. Belgium, Greece, Hungary, the Netherlands, Norway, and Spain. Test-retest reliability was assessed using the intra-class correlation coefficient (ICC) and percentage agreement comparing scores from two measurements, administered one week apart. To assess construct validity, the agreement between questionnaire responses and a subsequent face-to-face interview was assessed using ICC and percentage agreement. Results Of the 150 questionnaire items, 115 (77%) showed good to excellent test-retest reliability as indicated by ICCs > .60 or percentage agreement ≥ 75%. Test-retest reliability was moderate for 34 items (23%) and poor for one item. Construct validity appeared to be good to excellent for 70 (47%) of the 150 items, as indicated by ICCs > .60 or percentage agreement ≥ 75%. From the other 80 items, construct validity was moderate for 39 (26%) and poor for 41 items (27%). Conclusions Our results demonstrate that the ENERGY-child questionnaire, assessing EBRBs of the child as well as personal, family, and school-environmental determinants related to these EBRBs, has good test-retest reliability and moderate to good construct validity for the large majority of items. PMID:22152048

  9. SLAC modulator system improvements and reliability results

    International Nuclear Information System (INIS)

    Donaldson, A.R.

    1998-06-01

    In 1995, an improvement project was completed on the 244 klystron modulators in the linear accelerator. The modulator system has been previously described. This article offers project details and their resulting effect on modulator and component reliability. Prior to the project, the authors had collected four operating cycles (1991 through 1995) of MTTF data. In this discussion, the '91 data will be excluded since the modulators operated at 60 Hz. The five periods following the '91 run were reviewed due to the common repetition rate at 120 Hz

  10. Test-retest reliability of the assessment of postural stability in typically developing children and in hearing impaired children.

    Science.gov (United States)

    De Kegel, A; Dhooge, I; Cambier, D; Baetens, T; Palmans, T; Van Waelvelde, H

    2011-04-01

    The purpose of this study was to establish test-retest reliability of centre of pressure (COP) measurements obtained by an AccuGait portable forceplate (ACG), mean COG sway velocity measured by a Basic Balance Master (BBM) and clinical balance tests in children with and without balance difficulties. 49 typically developing children and 23 hearing impaired children, with a higher risk for stability problems, between 6 and 12 years of age participated. Each child performed the modified Clinical Test of Sensory Interaction on Balance (mCTSIB), Unilateral Stance (US) and Tandem Stance on ACG, mCTSIB and US on BBM and clinical balance tests: one-leg standing, balance beam walking and one-leg hopping. All subjects completed 2 test sessions on 2 different days in the same week assessed by the same examiner. Among COP measurements obtained by the ACG, mean sway velocity was the most reliable parameter with all ICCs higher than 0.72. The standard deviation (SD) of sway velocity, sway area, SD of anterior-posterior and SD of medio-lateral COP data showed moderate to excellent reliability with ICCs between 0.55 and 0.96 but some caution must be taken into account in some conditions. BBM is less reliable but clinical balance tests are as reliable as ACG. Hearing impaired children exhibited better relative reliability (ICC) and comparable absolute reliability (SEM) for most balance parameters compared to typically developing children. Reliable information regarding postural stability of typically developing children and hearing impaired children may be obtained utilizing COP measurements generated by an AccuGait system and clinical balance tests. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Reliability and validity of videotaped functional performance tests in ACL-injured subjects

    DEFF Research Database (Denmark)

    von Porat, Anette; Holmström, Eva; Roos, Ewa

    2008-01-01

    BACKGROUND AND PURPOSE: In clinical practice, visual observation is often used to determine functional impairment and to evaluate treatment following a knee injury. The aim of this study was to evaluate the reliability and validity of observational assessments of knee movement pattern quality......, crossover hop on one leg and one-leg hop. The videos were observed by four physiotherapists, and the knee movement pattern quality, a feature of the loading strategy of the lower extremity, was scored on an 11-point rating scale. To assess the criterion validity, the observational rating was correlated...... obtained between the observers' assessment and knee flexion angle, r = 0.37-0.61. The crossover hop test or one-leg hop test was ranked as the most useful test in 172 of 192 occasions (90%) when assessing knee function. CONCLUSION: The moderate to good inter-observer reliability and the moderate criterion...

  12. Reliability, validity and description of timed performance of the Jebsen-Taylor Test in patients with muscular dystrophies.

    Science.gov (United States)

    Artilheiro, Mariana Cunha; Fávero, Francis Meire; Caromano, Fátima Aparecida; Oliveira, Acary de Souza Bulle; Carvas, Nelson; Voos, Mariana Callil; Sá, Cristina Dos Santos Cardoso de

    2017-12-08

    The Jebsen-Taylor Test evaluates upper limb function by measuring timed performance on everyday activities. The test is used to assess and monitor the progression of patients with Parkinson disease, cerebral palsy, stroke and brain injury. To analyze the reliability, internal consistency and validity of the Jebsen-Taylor Test in people with Muscular Dystrophy and to describe and classify upper limb timed performance of people with Muscular Dystrophy. Fifty patients with Muscular Dystrophy were assessed. Non-dominant and dominant upper limb performances on the Jebsen-Taylor Test were filmed. Two raters evaluated timed performance for inter-rater reliability analysis. Test-retest reliability was investigated by using intraclass correlation coefficients. Internal consistency was assessed using the Cronbach alpha. Construct validity was conducted by comparing the Jebsen-Taylor Test with the Performance of Upper Limb. The internal consistency of Jebsen-Taylor Test was good (Cronbach's α=0.98). A very high inter-rater reliability (0.903-0.999), except for writing with an Intraclass correlation coefficient of 0.772-1.000. Strong correlations between the Jebsen-Taylor Test and the Performance of Upper Limb Module were found (rho=-0.712). The Jebsen-Taylor Test is a reliable and valid measure of timed performance for people with Muscular Dystrophy. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  13. Foster Wheeler Solar Development Corporation modular industrial solar retrofit qualification test results

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, C.P.; Dudley, V.E.; Lewandoski, A.A.

    1986-10-01

    Under the Department of Energy's Modular Industrial Solar Retrofit project, industrial process steam systems incorporating line-focus solar thermal collectors were designed and hardware was installed and tested. This report describes the test results for the system designed by Foster Wheeler Solar Development Corporation. The test series included function and safety tests to determine that the system operated as specified, an unattended operations test to demonstrate automatic operation, performance tests to provide a database for predicting system performance, and life cycle tests to evaluate component and maintenance requirements. Component-level modifications to improve system performance and reliability were also evaluated.

  14. Foster Wheeler Solar Development Corporation Modular Industrial Solar Retrofit qualification test results

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, C.P.; Dudley, V.E.; Lewandowski, A.A.

    1987-04-01

    Under the Department of Energy's Modular Industrial Solar Retrofit project, industrial process steam systems incorporating line-focus solar thermal collectors were designed and hardware was installed and tested. This report describes the test results for the system designed by Foster Wheeler Solar Development Corporation. The test series included function and safety tests to determine that the system operated as specified, an unattended operations test to demonstrate automatic operation, performance tests to provide a database for predicting system performance, and life cycle tests to evaluate component and maintenance requirements. Component-level modifications to improve system performance and reliability were also evaluated.

  15. Reliability of thermal interface materials: A review

    International Nuclear Information System (INIS)

    Due, Jens; Robinson, Anthony J.

    2013-01-01

    Thermal interface materials (TIMs) are used extensively to improve thermal conduction across two mating parts. They are particularly crucial in electronics thermal management since excessive junction-to-ambient thermal resistances can cause elevated temperatures which can negatively influence device performance and reliability. Of particular interest to electronic package designers is the thermal resistance of the TIM layer at the end of its design life. Estimations of this allow the package to be designed to perform adequately over its entire useful life. To this end, TIM reliability studies have been performed using accelerated stress tests. This paper reviews the body of work which has been performed on TIM reliability. It focuses on the various test methodologies with commentary on the results which have been obtained for the different TIM materials. Based on the information available in the open literature, a test procedure is proposed for TIM selection based on beginning and end of life performance. - Highlights: ► This paper reviews the body of work which has been performed on TIM reliability. ► Test methodologies for reliability testing are outlined. ► Reliability results for the different TIM materials are discussed. ► A test procedure is proposed for TIM selection BOLife and EOLife performance.

  16. Reliability Generalization: Exploring Variation of Reliability Coefficients of MMPI Clinical Scales Scores.

    Science.gov (United States)

    Vacha-Haase, Tammi; Kogan, Lori R.; Tani, Crystal R.; Woodall, Renee A.

    2001-01-01

    Used reliability generalization to explore the variance of scores on 10 Minnesota Multiphasic Personality Inventory (MMPI) clinical scales drawing on 1,972 articles in the literature on the MMPI. Results highlight the premise that scores, not tests, are reliable or unreliable, and they show that study characteristics do influence scores on the…

  17. Reliability of isometric subtalar pronator and supinator strength testing.

    Science.gov (United States)

    Hagen, Marco; Lahner, Matthias; Winhuysen, Martin; Maiwald, Christian

    2015-01-01

    Due to the specific anatomy of the subtalar joint with its oblique axis, isometric pronator and supinator strength is not well documented. The purpose of this study was to determine intra- and between-session reliability of pronator and supinator strength and lower leg muscle activity measurements during maximum voluntary isometric contractions (MVIC). Pronator and supinator peak torques (PT), with and without supplementary visual muscle strength biofeedback (FB), and muscular activities of peroneus longus (PL) and tibialis anterior (TA) were assessed twice 3 days apart by the same examiner in 21 healthy young male adults (mean age: 27.6 years; SD = 3.9). Limits of agreement (LoA) and minimum detectable change (MDC) were evaluated. By applying FB, reliability of both pronator and supinator PT was improved: LoA were reduced from 32% to 26% and from 20% to 18% and MDC from 20% to 15% and from 16% to 12% in supinator and pronator PT, respectively. Learning effects in pronator and supinator PT (p isometric subtalar pronator and supinator strength testing is reliable in healthy subjects. LoA of 18% and 26% have to be exceeded for pronator and supinator PT, respectively, to detect relevant effects in repeated measures.

  18. Test-Retest Reliability of the Preschool Age Psychiatric Assessment (PAPA)

    Science.gov (United States)

    Egger, Helen Link; Erkanli, Alaattin; Keeler, Gordon; Potts, Edward; Walter, Barbara Keith; Angold, Adrian

    2006-01-01

    Objective: To examine the test-retest reliability of a new interviewer-based psychiatric diagnostic measure (the Preschool Age Psychiatric Assessment) for use with parents of preschoolers 2 to 5 years old. Method: A total of 1,073 parents of children attending a large pediatric clinic completed the Child Behavior Checklist 1 1/2-5. For 18 months,…

  19. Establishing the Test-Retest Reliability & Concurrent Validity for the Repeat Ice Skating Test (RIST) in Adolescent Male Ice Hockey Players

    Science.gov (United States)

    Power, Allan; Faught, Brent E.; Przysucha, Eryk; McPherson, Moira; Montelpare, William

    2012-01-01

    In this study the authors examine the test-retest reliability and concurrent validity of the Repeat Ice Skating Test (RIST). This was an on-ice field anaerobic test that measured average peak power and was validated with 3 anaerobic lab tests: (a) vertical jump, (b) the Margaria-Kalamen stair test, and (c) the Wingate Anaerobic Test. The…

  20. Test-retest reliability of the proposed DSM-5 eating disorder diagnostic criteria

    Science.gov (United States)

    Sysko, Robyn; Roberto, Christina A.; Barnes, Rachel D.; Grilo, Carlos M.; Attia, Evelyn; Walsh, B. Timothy

    2012-01-01

    The proposed DSM-5 classification scheme for eating disorders includes both major and minor changes to the existing DSM-IV diagnostic criteria. It is not known what effect these modifications will have on the ability to make reliable diagnoses. Two studies were conducted to evaluate the short-term test-retest reliability of the proposed DSM-5 eating disorder diagnoses: anorexia nervosa, bulimia nervosa, binge eating disorder, and feeding and eating conditions not elsewhere classified. Participants completed two independent telephone interviews with research assessors (n=70 Study 1; n=55 Study 2). Fair to substantial agreements (κ= 0.80 and 0.54) were observed across eating disorder diagnoses in Study 1 and Study 2, respectively. Acceptable rates of agreement were identified for the individual eating disorder diagnoses, including DSM-5 anorexia nervosa (κ’s of 0.81 to 0.97), bulimia nervosa (κ=0.84), binge eating disorder (κ’s of 0.75 and 0.61), and feeding and eating disorders not elsewhere classified (κ’s of 0.70 and 0.46). Further, improved short-term test-retest reliability was noted when using the DSM-5, in comparison to DSM-IV, criteria for binge eating disorder. Thus, these studies found that trained interviewers can reliably diagnose eating disorders using the proposed DSM-5 criteria; however, additional data from general practice settings and community samples are needed. PMID:22401974

  1. Content Validity Index and Intra- and Inter-Rater Reliability of a New Muscle Strength/Endurance Test Battery for Swedish Soldiers.

    Directory of Open Access Journals (Sweden)

    Helena Larsson

    Full Text Available The objective of this study was to examine the content validity of commonly used muscle performance tests in military personnel and to investigate the reliability of a proposed test battery. For the content validity investigation, thirty selected tests were those described in the literature and/or commonly used in the Nordic and North Atlantic Treaty Organization (NATO countries. Nine selected experts rated, on a four-point Likert scale, the relevance of these tests in relation to five different work tasks: lifting, carrying equipment on the body or in the hands, climbing, and digging. Thereafter, a content validity index (CVI was calculated for each work task. The result showed excellent CVI (≥0.78 for sixteen tests, which comprised of one or more of the military work tasks. Three of the tests; the functional lower-limb loading test (the Ranger test, dead-lift with kettlebells, and back extension, showed excellent content validity for four of the work tasks. For the development of a new muscle strength/endurance test battery, these three tests were further supplemented with two other tests, namely, the chins and side-bridge test. The inter-rater reliability was high (intraclass correlation coefficient, ICC2,1 0.99 for all five tests. The intra-rater reliability was good to high (ICC3,1 0.82-0.96 with an acceptable standard error of mean (SEM, except for the side-bridge test (SEM%>15. Thus, the final suggested test battery for a valid and reliable evaluation of soldiers' muscle performance comprised the following four tests; the Ranger test, dead-lift with kettlebells, chins, and back extension test. The criterion-related validity of the test battery should be further evaluated for soldiers exposed to varying physical workload.

  2. Ball-Sport Endurance and Sprint Test (BEAST90): validity and reliability of a 90-minute soccer performance test.

    Science.gov (United States)

    Williams, Jeremy D; Abt, Grant; Kilding, Andrew E

    2010-12-01

    The aim of this study was to determine the validity and reliability of a 90-minute soccer performance test: Ball-sport Endurance and Sprint Test (BEAST90). Fifteen healthy male amateur soccer players participated and attended 5 testing sessions over a 10-day period to perform physiologic and soccer-specific assessments. This included familiarization sessions and 2 full trials of the BEAST90, separated by 7 days. The total 90-minute distance, mean percent peak heart rate (HRpeak), and estimated percent peak oxygen uptake of the BEAST90 were 8,097 ± 458 m, 85 ± 5% and 82 ± 14%, respectively. Measures obtained from trial 1 and trial 2 were not significantly different (p > 0.05). Reliability of measures over 90 minutes ranged from 0.9-25.5% (% typical error). The BEAST90 protocol replicated soccer match play in terms of time, movement patterns, physical demands (volume and intensity), distances, and mean and HRpeak values, as well as having an aerobic load similar to that observed during a soccer match. Reproducibility of key physical measures during the BEAST90 were mostly high, suggesting good reliability. The BEAST90 could be used in studies that wish to determine the effects of training or nutritional interventions on prolonged intermittent physical performance.

  3. Validation and Reliability of a Novel Test of Upper Body Isometric Strength

    Directory of Open Access Journals (Sweden)

    Bellar David

    2015-09-01

    Full Text Available The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4% volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a “push-up” style position while tethered (stainless steel chain to a load cell (high frequency anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98 suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001 with all predictor variables attaining significance in the model (p<0.05. Isometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001. Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment.

  4. Validation and Reliability of a Novel Test of Upper Body Isometric Strength

    Science.gov (United States)

    Bellar, David; Marcus, Lena; Judge, Lawrence W.

    2015-01-01

    The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4%) volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a “push-up” style position while tethered (stainless steel chain) to a load cell (high frequency) anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98) suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001) with all predictor variables attaining significance in the model (p<0.05). Isometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001). Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment. PMID:26557203

  5. Translation, Validation, and Reliability of the Dutch Late-Life Function and Disability Instrument Computer Adaptive Test.

    Science.gov (United States)

    Arensman, Remco M; Pisters, Martijn F; de Man-van Ginkel, Janneke M; Schuurmans, Marieke J; Jette, Alan M; de Bie, Rob A

    2016-09-01

    Adequate and user-friendly instruments for assessing physical function and disability in older adults are vital for estimating and predicting health care needs in clinical practice. The Late-Life Function and Disability Instrument Computer Adaptive Test (LLFDI-CAT) is a promising instrument for assessing physical function and disability in gerontology research and clinical practice. The aims of this study were: (1) to translate the LLFDI-CAT to the Dutch language and (2) to investigate its validity and reliability in a sample of older adults who spoke Dutch and dwelled in the community. For the assessment of validity of the LLFDI-CAT, a cross-sectional design was used. To assess reliability, measurement of the LLFDI-CAT was repeated in the same sample. The item bank of the LLFDI-CAT was translated with a forward-backward procedure. A sample of 54 older adults completed the LLFDI-CAT, World Health Organization Disability Assessment Schedule 2.0, RAND 36-Item Short-Form Health Survey physical functioning scale (10 items), and 10-Meter Walk Test. The LLFDI-CAT was repeated in 2 to 8 days (mean=4.5 days). Pearson's r and the intraclass correlation coefficient (ICC) (2,1) were calculated to assess validity, group-level reliability, and participant-level reliability. A correlation of .74 for the LLFDI-CAT function scale and the RAND 36-Item Short-Form Health Survey physical functioning scale (10 items) was found. The correlations of the LLFDI-CAT disability scale with the World Health Organization Disability Assessment Schedule 2.0 and the 10-Meter Walk Test were -.57 and -.53, respectively. The ICC (2,1) of the LLFDI-CAT function scale was .84, with a group-level reliability score of .85. The ICC (2,1) of the LLFDI-CAT disability scale was .76, with a group-level reliability score of .81. The high percentage of women in the study and the exclusion of older adults with recent joint replacement or hospitalization limit the generalizability of the results. The Dutch LLFDI

  6. Test-Retest Reliability and Minimal Detectable Change of Randomized Dichotic Digits in Learning-Disabled Children: Implications for Dichotic Listening Training.

    Science.gov (United States)

    Mahdavi, Mohammad Ebrahim; Pourbakht, Akram; Parand, Akram; Jalaie, Shohreh

    2018-03-01

    Evaluation of dichotic listening to digits is a common part of many studies for diagnosis and managing auditory processing disorders in children. Previous researchers have verified test-retest relative reliability of dichotic digits results in normal children and adults. However, detecting intervention-related changes in the ear scores after dichotic listening training requires information regarding trial-to-trial typical variation of individual ear scores that is estimated using indices of absolute reliability. Previous studies have not addressed absolute reliability of dichotic listening results. To compare the results of the Persian randomized dichotic digits test (PRDDT) and its relative and absolute indices of reliability between typical achieving (TA) and learning-disabled (LD) children. A repeated measures observational study. Fifteen LD children were recruited from a previously performed study with age range of 7-12 yr. The control group consisted of 15 TA schoolchildren with age range of 8-11 yr. The Persian randomized dichotic digits test was administered on the children under free recall condition in two test sessions 7-12 days apart. We compared the average of the ear scores and ear advantage between TA and LD children. Relative indices of reliability included Pearson's correlation and intraclass correlation (ICC 2,1 ) coefficients and absolute reliability was evaluated by calculation of standard error of measurement (SEM) and minimal detectable change (MDC) using the raw ear scores. The Pearson correlation coefficient indicated that in both groups of children the ear scores of test and retest sessions were strongly and positively (greater than +0.8) correlated. The ear scores showed excellent ICC coefficient of consistency (0.78-0.82) and fair to excellent ICC coefficient of absolute agreement (0.62-0.74) in TA children and excellent ICC coefficients of consistency and absolute agreement in LD children (0.76-0.87). SEM and SEM% of the ear scores in TA

  7. Test-retest, inter-assessor and intra-assessor reliability of the modified Touwen examination

    NARCIS (Netherlands)

    Peters, Lieke H. J.; Maathuis, Karel G. B.; Kouw, Eva; Hamming, Marjolein; Hadders-Algra, Mijna

    Interest in the Touwen examination (1979) for the assessment of minor neurological dysfunction (MND) is growing. However, information on psychometric properties of this assessment is scarce. Therefore the present study aimed at assessing the test's test-retest, inter- and intra-assessor reliability.

  8. Test-Retest Reliability of Handgrip Strength as an Outcome Measure in Patients With Symptoms of Shoulder Impingement Syndrome.

    Science.gov (United States)

    Savva, Christos; Mougiaris, Paraskevas; Xadjimichael, Christoforos; Karagiannis, Christos; Efstathiou, Michalis

    The purpose of this study was to investigate the degree of test-retest reliability of grip strength measurement using a hand dynamometer in patients with shoulder impingement syndrome. A total of 19 patients (10 women and 9 men; mean ± standard deviation age, 33.2 ± 12.9 years; range 18-59 years) with shoulder impingement syndrome were measured using a hand dynamometer by the same data collector in 2 different testing sessions with a 7-day interval. During each session, patients were encouraged to exert 3 maximal isometric contractions on the affected hand and the mean value of the 3 efforts (measured in kilogram-force [Kgf]) was used for data analysis. The intraclass correlation coefficient (ICC 2,1 ) as well as the standard error of measurement (SEM) and Bland-Altman plot were used to estimate the degree of test-retest reliability and the measurement error, respectively. Grip strength data analysis revealed an ICC 2,1 score of 0.94, which, based on the Shrout classification, is considered as excellent test-retest reliability of grip strength measurement. The small values of SEMs reported in both sessions (SEM 1 , 2.55 Kgf; SEM 2 , 2.39 Kgf) and the small width of the 95% limits of agreement in the Bland-Altman plot (ranging from -7.39 Kgf to 7.03 Kgf) reflected the measurement precision and the narrow variation of the differences during the 2 testing sessions. Results from this study identified excellent test-retest reliability of grip strength measurement in shoulder impingement syndrome, indicating its potential use as an outcome measure in clinical practice. Copyright © 2018. Published by Elsevier Inc.

  9. Reliability characteristics and applicability of a repeated sprint ability test in male young soccer players

    DEFF Research Database (Denmark)

    Castagna, Carlo; Francini, Lorenzo; Krustrup, Peter

    2018-01-01

    The aim of this study was to examine the usefulness and reliability characteristics of a repeated sprint ability test considering 5 line sprints of 30-m interspersed with 30-s of active recovery in non-elite outfield young male soccer players. Twenty-six (age 14.9±1.2 years, height 1.72±0.12 cm......, body mass 62.2±5.1 kg) players were tested 48 hours and 7 days apart for 5x30-m performance over 5 trials (T1-T5). Short- (T1-T2) and long-term reliability (T1-T3-T4-T5) were assessed with Intraclass Correlation Coefficient (ICC) and with typical error for measurement (TEM). Short- and long...... study revealed that the 5x30-m sprint test is a reliable field test in the short and long-term when the sum of sprint times and the best sprint performance are considered as outcome variables. Sprint performance decrements variables showed large variability across trials....

  10. Methodology for performing RF reliability experiments on a generic test structure

    NARCIS (Netherlands)

    Sasse, G.T.; de Vries, Rein J.; Schmitz, Jurriaan

    2007-01-01

    This paper discusses a new technique developed for generating well defined RF large voltage swing signals for on wafer experiments. This technique can be employed for performing a broad range of different RF reliability experiments on one generic test structure. The frequency dependence of a

  11. Test-retest reliability of a questionnaire to assess physical environmental factors pertaining to physical activity

    Directory of Open Access Journals (Sweden)

    McGinn Aileen P

    2005-06-01

    Full Text Available Abstract Background Despite the documented benefits of physical activity, many adults do not obtain the recommended amounts. Barriers to physical activity occur at multiple levels, including at the individual, interpersonal, and environmental levels. Only until more recently has there been a concerted focus on how the physical environment might affect physical activity behavior. With this new area of study, self-report measures should be psychometrically tested before use in research studies. Therefore the objective of this study was to document the test-retest reliability of a questionnaire designed to assess physical environmental factors that might be associated with physical activity in a diverse adult population. Methods Test and retest surveys were conducted over the telephone with 106 African American and White women and men living in either Forsyth County, North Carolina or Jackson, Mississippi. Reliability of self-reported environmental factors across four domains (e.g., access to facilities and destinations, functionality and safety, aesthetics, natural environment was determined using intraclass correlation coefficients (ICC overall and separately by gender and race. Results Generally items displayed moderate and sometimes substantial reliability (ICC between 0.4 to 0.8, with a few differences by gender or race, across each of the domains. Conclusion This study provides some psychometric evidence for the use of many of these questions in studies examining the effect of self-reported physical environmental measures on physical activity behaviors, among African American and White women and men.

  12. Mechanically braked elliptical Wingate test: modification considerations, load optimization, and reliability.

    Science.gov (United States)

    Ozkaya, Ozgur; Colakoglu, Muzaffer; Kuzucu, Erinc O; Yildiztepe, Engin

    2012-05-01

    The 30-second, all-out Wingate test evaluates anaerobic performance using an upper or lower body cycle ergometer (cycle Wingate test). A recent study showed that using a modified electromagnetically braked elliptical trainer for Wingate testing (EWT) leads to greater power outcomes because of larger muscle group recruitment. The main purpose of this study was to modify an elliptical trainer using an easily understandable mechanical brake system instead of an electromagnetically braked modification. Our secondary aim was to determine a proper test load for the EWT to reveal the most efficient anaerobic test outcomes such as peak power (PP), average power (AP), minimum power (MP), power drop (PD), and fatigue index ratio (FI%) and to evaluate the retest reliability of the selected test load. Delta lactate responses (ΔLa) were also analyzed to confirm all the anaerobic performance of the athletes. Thirty healthy and well-trained male university athletes were selected to participate in the study. By analysis of variance, an 18% body mass workload yielded significantly greater test outcomes (PP = 19.5 ± 2.4 W·kg, AP = 13.7 ± 1.7 W·kg, PD = 27.9 ± 5 W·s, FI% = 58.4 ± 3.3%, and ΔLa = 15.4 ± 1.7 mM) than the other (12-24% body mass) tested loads (p braked modification of an elliptical trainer successfully estimated anaerobic power and capacity. A workload of 18% body mass was optimal for measuring maximal and reliable anaerobic power outcomes. Anaerobic testing using an EWT may be more useful to athletes and coaches than traditional cycle ergometers because a greater proportion of muscle groups are worked during exercise on an elliptical trainer.

  13. A Test-Retest Reliability Study of the Whiplash Disability Questionnaire in Patients With Acute Whiplash-Associated Disorders

    DEFF Research Database (Denmark)

    Stupar, Maja; Côté, Pierre; Beaton, Dorcas E

    2015-01-01

    OBJECTIVE: The purpose of this study was to determine the test-retest reliability and the Minimal Detectable Change (MDC) of the Whiplash Disability Questionnaire (WDQ) in individuals with acute whiplash-associated disorders (WADs). METHODS: We performed a test-retest reliability study. We includ...

  14. A fracture mechanics and reliability based method to assess non-destructive testings for pressure vessels

    International Nuclear Information System (INIS)

    Kitagawa, Hideo; Hisada, Toshiaki

    1979-01-01

    Quantitative evaluation has not been made on the effects of carrying out preservice and in-service nondestructive tests for securing the soundness, safety and maintainability of pressure vessels, spending large expenses and labor. Especially the problems concerning the time and interval of in-service inspections lack the reasonable, quantitative evaluation method. In this paper, the problems of pressure vessels are treated by having developed the analysis method based on reliability technology and probability theory. The growth of surface cracks in pressure vessels was estimated, using the results of previous studies. The effects of nondestructive inspection on the defects in pressure vessels were evaluated, and the influences of many factors, such as plate thickness, stress, the accuracy of inspection and so on, on the effects of inspection, and the method of evaluating the inspections at unequal intervals were investigated. The analysis of reliability taking in-service inspection into consideration, the evaluation of in-service inspection and other affecting factors through the typical examples of analysis, and the review concerning the time of inspection are described. The method of analyzing the reliability of pressure vessels, considering the growth of defects and preservice and in-service nondestructive tests, was able to be systematized so as to be practically usable. (Kako, I.)

  15. Evaluating abdominal core muscle fatigue: Assessment of the validity and reliability of the prone bridging test.

    Science.gov (United States)

    De Blaiser, C; De Ridder, R; Willems, T; Danneels, L; Vanden Bossche, L; Palmans, T; Roosen, P

    2018-02-01

    The aims of this study were to research the amplitude and median frequency characteristics of selected abdominal, back, and hip muscles of healthy subjects during a prone bridging endurance test, based on surface electromyography (sEMG), (a) to determine if the prone bridging test is a valid field test to measure abdominal muscle fatigue, and (b) to evaluate if the current method of administrating the prone bridging test is reliable. Thirty healthy subjects participated in this experiment. The sEMG activity of seven abdominal, back, and hip muscles was bilaterally measured. Normalized median frequencies were computed from the EMG power spectra. The prone bridging tests were repeated on separate days to evaluate inter and intratester reliability. Significant differences in normalized median frequency slope (NMF slope ) values between several abdominal, back, and hip muscles could be demonstrated. Moderate-to-high correlation coefficients were shown between NMF slope values and endurance time. Multiple backward linear regression revealed that the test endurance time could only be significantly predicted by the NMF slope of the rectus abdominis. Statistical analysis showed excellent reliability (ICC=0.87-0.89). The findings of this study support the validity and reliability of the prone bridging test for evaluating abdominal muscle fatigue. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Exploring the reliability and validity of the social-moral awareness test.

    Science.gov (United States)

    Livesey, Alexandra; Dodd, Karen; Pote, Helen; Marlow, Elizabeth

    2012-11-01

    The aim of the study was to explore the validity of the social-moral awareness test (SMAT) a measure designed for assessing socio-moral rule knowledge and reasoning in people with learning disabilities. Comparisons between Theory of Mind and socio-moral reasoning allowed the exploration of construct validity of the tool. Factor structure, reliability and discriminant validity were also assessed. Seventy-one participants with mild-moderate learning disabilities completed the two scales of the SMAT and two False Belief Tasks for Theory of Mind. Reliability of the SMAT was very good, and the scales were shown to be uni-dimensional in factor structure. There was a significant positive relationship between Theory of Mind and both SMAT scales. There is early evidence of the construct validity and reliability of the SMAT. Further assessment of the validity of the SMAT will be required. © 2012 Blackwell Publishing Ltd.

  17. Test-retest reliability of myofascial trigger point detection in hip and thigh areas.

    Science.gov (United States)

    Rozenfeld, E; Finestone, A S; Moran, U; Damri, E; Kalichman, L

    2017-10-01

    Myofascial trigger points (MTrP's) are a primary source of pain in patients with musculoskeletal disorders. Nevertheless, they are frequently underdiagnosed. Reliable MTrP palpation is the necessary for their diagnosis and treatment. The few studies that have looked for intra-tester reliability of MTrPs detection in upper body, provide preliminary evidence that MTrP palpation is reliable. Reliability tests for MTrP palpation on the lower limb have not yet been performed. To evaluate inter- and intra-tester reliability of MTrP recognition in hip and thigh muscles. Reliability study. 21 patients (15 males and 6 females, mean age 21.1 years) referred to the physical therapy clinic, 10 with knee or hip pain and 11 with pain in an upper limb, low back, shin or ankle. Two experienced physical therapists performed the examinations, blinded to the subjects' identity, medical condition and results of the previous MTrP evaluation. Each subject was evaluated four times, twice by each examiner in a random order. Dichotomous findings included a palpable taut band, tenderness, referred pain, and relevance of referred pain to patient's complaint. Based on these, diagnosis of latent MTrP's or active MTrP's was established. The evaluation was performed on both legs and included a total of 16 locations in the following muscles: rectus femoris (proximal), vastus medialis (middle and distal), vastus lateralis (middle and distal) and gluteus medius (anterior, posterior and distal). Inter- and intra-tester reliability (Cohen's kappa (κ)) values for single sites ranged from -0.25 to 0.77. Median intra-tester reliability was 0.45 and 0.46 for latent and active MTrP's, and median inter-tester reliability was 0.51 and 0.64 for latent and active MTrPs, respectively. The examination of the distal vastus medialis was most reliable for latent and active MTrP's (intra-tester k = 0.27-0.77, inter-tester k = 0.77 and intra-tester k = 0.53-0.72, inter-tester k = 0.72, correspondingly

  18. Equipment design for reliability testing of protection system

    International Nuclear Information System (INIS)

    Situmorang, Johnny; Tjahjono, H.; Santosa, A. Z.; Tjahjani, S.DT.; Ismu, P.H; Haryanto, D.; Mulyanto, D.; Kusmono, S

    1999-01-01

    The equipment for reliability testing of cable of protection system has been designed as a a furnace with the electric heater have a 4 kW power, and need time 10 minute to reach the designed maximum temperature 3000C. The dimension of furnace is 800 mm diameter and 2000 mm length is isolated use rockwool isolator and coated by aluminium. For the designed maximum temperature the surface temperature is 78 0c. Assemble of specimens is arranged horizontally in the furnace. The failure criteria will be defined based on the behaviour of the load circuit in each line of cable specimens

  19. A reliability generalization meta-analysis of coefficient alpha and test-retest coefficient for the aging males' symptoms (AMS) scale.

    Science.gov (United States)

    Lee, Chin-Pang; Chiu, Yu-Wen; Chu, Chun-Lin; Chen, Yu; Jiang, Kun-Hao; Chen, Jiun-Liang; Chen, Ching-Yen

    2016-12-01

    The aging males' symptoms (AMS) scale is an instrument used to determine the health-related quality of life in adult and elderly men. The purpose of this study was to synthesize internal consistency (Cronbach's alpha) and test-retest reliability for the AMS scale and its three subscales. Of the 123 studies reviewed, 12 provided alpha coefficients which were then used in the meta-analyses of internal consistency. Seven of the 12 included studies provided test-retest coefficients, and these were used in the meta-analyses of test-retest reliability. The AMS scale had excellent internal consistency [α = 0.89 (95% CI 0.88-0.90)]; the mean alpha estimates across the AMS subscales ranged from 0.79 to 0.82. The AMS scale also had good test-retest reliability [r = 0.85 (95% CI 0.82-0.88]; the test-retest reliability coefficients of the AMS subscales ranged from 0.76 to 0.83. There was significant heterogeneity among the included studies. The AMS scale and the three subscales had fairly good internal consistency and test-retest reliability. Future psychometric studies of the AMS scale should report important characteristics of the participants, details of item scores, and test-retest reliability.

  20. Effects of Analytical and Holistic Scoring Patterns on Scorer Reliability in Biology Essay Tests

    Science.gov (United States)

    Ebuoh, Casmir N.

    2018-01-01

    Literature revealed that the patterns/methods of scoring essay tests had been criticized for not being reliable and this unreliability is more likely to be more in internal examinations than in the external examinations. The purpose of this study is to find out the effects of analytical and holistic scoring patterns on scorer reliability in…

  1. Reliability and Concurrent Validity of the Narrow Path Walking Test in Persons With Multiple Sclerosis.

    Science.gov (United States)

    Rosenblum, Uri; Melzer, Itshak

    2017-01-01

    About 90% of people with multiple sclerosis (PwMS) have gait instability and 50% fall. Reliable and clinically feasible methods of gait instability assessment are needed. The study investigated the reliability and validity of the Narrow Path Walking Test (NPWT) under single-task (ST) and dual-task (DT) conditions for PwMS. Thirty PwMS performed the NPWT on 2 different occasions, a week apart. Number of Steps, Trial Time, Trial Velocity, Step Length, Number of Step Errors, Number of Cognitive Task Errors, and Number of Balance Losses were measured. Intraclass correlation coefficients (ICC2,1) were calculated from the average values of NPWT parameters. Absolute reliability was quantified from standard error of measurement (SEM) and smallest real difference (SRD). Concurrent validity of NPWT with Functional Reach Test, Four Square Step Test (FSST), 12-item Multiple Sclerosis Walking Scale (MSWS-12), and 2 Minute Walking Test (2MWT) was determined using partial correlations. Intraclass correlation coefficients (ICCs) for most NPWT parameters during ST and DT ranged from 0.46-0.94 and 0.55-0.95, respectively. The highest relative reliability was found for Number of Step Errors (ICC = 0.94 and 0.93, for ST and DT, respectively) and Trial Velocity (ICC = 0.83 and 0.86, for ST and DT, respectively). Absolute reliability was high for Number of Step Errors in ST (SEM % = 19.53%) and DT (SEM % = 18.14%) and low for Trial Velocity in ST (SEM % = 6.88%) and DT (SEM % = 7.29%). Significant correlations for Number of Step Errors and Trial Velocity were found with FSST, MSWS-12, and 2MWT. In persons with PwMS performing the NPWT, Number of Step Errors and Trial Velocity were highly reliable parameters. Based on correlations with other measures of gait instability, Number of Step Errors was the most valid parameter of dynamic balance under the conditions of our test.Video Abstract available for more insights from the authors (see Supplemental Digital Content 1, available at: http

  2. Reliability and validity of the new Tanaka B Intelligence Scale scores: a group intelligence test.

    Science.gov (United States)

    Uno, Yota; Mizukami, Hitomi; Ando, Masahiko; Yukihiro, Ryoji; Iwasaki, Yoko; Ozaki, Norio

    2014-01-01

    The present study evaluated the reliability and concurrent validity of the new Tanaka B Intelligence Scale, which is an intelligence test that can be administered on groups within a short period of time. The new Tanaka B Intelligence Scale and Wechsler Intelligence Scale for Children-Third Edition were administered to 81 subjects (mean age ± SD 15.2 ± 0.7 years) residing in a juvenile detention home; reliability was assessed using Cronbach's alpha coefficient, and concurrent validity was assessed using the one-way analysis of variance intraclass correlation coefficient. Moreover, receiver operating characteristic analysis for screening for individuals who have a deficit in intellectual function (an FIQIntelligence Scale IQ (BIQ) was 0.86, and the intraclass correlation coefficient with FIQ was 0.83. Receiver operating characteristic analysis demonstrated an area under the curve of 0.89 (95% CI: 0.85-0.96). In addition, the stratum-specific likelihood ratio for the BIQ≤65 stratum was 13.8 (95% CI: 3.9-48.9), and the stratum-specific likelihood ratio for the BIQ≥76 stratum was 0.1 (95% CI: 0.03-0.4). Thus, intellectual disability could be ruled out or determined. The present results demonstrated that the new Tanaka B Intelligence Scale score had high reliability and concurrent validity with the Wechsler Intelligence Scale for Children-Third Edition score. Moreover, the post-test probability for the BIQ could be calculated when screening for individuals who have a deficit in intellectual function. The new Tanaka B Intelligence Test is convenient and can be administered within a variety of settings. This enables evaluation of intellectual development even in settings where performing intelligence tests have previously been difficult.

  3. CIEMAT interlaboratories comparison of the results obtained in the proficiency test run by IAEA

    International Nuclear Information System (INIS)

    Gasco, C.; Anton, M. P.; Alvarez, A.; Navarro, N.; Meral, J.; Gonzalez, A.; Higueras Lafaja, E.

    2000-01-01

    This report contains the results obtained by two different laboratories from CIEMAT after participating in the Proficiency Test organised by IAEA (International Atomic Energy Agency) in 1999. This test involves the analysis of fly ashes containing natural radionuclides and different amounts of added transuranics. The extraction techniques, counting methods and results obtained are detailed. This type of test are used for the labs to achieve their accreditation and check the reliability of the procedures routinely employed. (Author) 4 refs

  4. Lifetime prediction and reliability estimation methodology for Stirling-type pulse tube refrigerators by gaseous contamination accelerated degradation testing

    Science.gov (United States)

    Wan, Fubin; Tan, Yuanyuan; Jiang, Zhenhua; Chen, Xun; Wu, Yinong; Zhao, Peng

    2017-12-01

    Lifetime and reliability are the two performance parameters of premium importance for modern space Stirling-type pulse tube refrigerators (SPTRs), which are required to operate in excess of 10 years. Demonstration of these parameters provides a significant challenge. This paper proposes a lifetime prediction and reliability estimation method that utilizes accelerated degradation testing (ADT) for SPTRs related to gaseous contamination failure. The method was experimentally validated via three groups of gaseous contamination ADT. First, the performance degradation model based on mechanism of contamination failure and material outgassing characteristics of SPTRs was established. Next, a preliminary test was performed to determine whether the mechanism of contamination failure of the SPTRs during ADT is consistent with normal life testing. Subsequently, the experimental program of ADT was designed for SPTRs. Then, three groups of gaseous contamination ADT were performed at elevated ambient temperatures of 40 °C, 50 °C, and 60 °C, respectively and the estimated lifetimes of the SPTRs under normal condition were obtained through acceleration model (Arrhenius model). The results show good fitting of the degradation model with the experimental data. Finally, we obtained the reliability estimation of SPTRs through using the Weibull distribution. The proposed novel methodology enables us to take less than one year time to estimate the reliability of the SPTRs designed for more than 10 years.

  5. Test-Retest Reliability of Isokinetic Knee Strength Measurements in Children Aged 8 to 10 Years.

    Science.gov (United States)

    Fagher, Kristina; Fritzson, Annelie; Drake, Anna Maria

    Isokinetic dynamometry is a useful tool to objectively assess muscle strength of children and adults in athletic and rehabilitative settings. This study examined test-retest reliability of isokinetic knee strength measurements in children aged 8 to 10 years and defined limits for the minimum difference (MD) in strength that indicates a clinically important change. Isokinetic knee strength measurements (using the Biodex System 4) in children will provide reliable results. Descriptive laboratory study. In 22 healthy children, 5 maximal concentric (CON) knee extensor (KE) and knee flexor (KF) contractions at 2 angular velocities (60 deg/s and 180 deg/s) and 5 maximal eccentric (ECC) KE/KF contractions at 60 deg/s were assessed 7 days apart. The intraclass correlation coefficient (ICC 2.1 ) was used to examine relative reliability, and the MD was calculated on the basis of standard error of measurement. ICCs for CON KE/KF peak torque measurements were fair to excellent (range, 0.49-0.81). The MD% values for CON KE and KF ranged from 31% to 37% at 60 deg/s and from 34% to 39% at 180 deg/s. ICCs in the ECC mode were good (range, 0.60-0.70), but associated MD% values were high (>50%). There was no systematic error for CON KE/KF and ECC KE strength measurements at 60 deg/s, but systematic error was found for all other measurements. The dynamometer provides a reliable analysis of isokinetic CON knee strength measurements at 60 deg/s in children aged 8 to 10 years. Measurements at 180 deg/s and in the ECC mode were not reliable, indicating a need for more familiarization prior to testing. The MD values may help clinicians to determine whether a change in knee strength is due to error or intervention.

  6. Results of HHF tests and metallographic investigation of beryllium HHF mockups

    International Nuclear Information System (INIS)

    Giniaytulin, R.; Komarov, V.; Mazul, I.; Yablokov, N.; Watson, R.; Cadden, C.; Yang, N.

    2000-01-01

    The reliability of the beryllium-armoured elements for any fusion facilities strongly depends from the armour tile geometry and determines by the armour thickness and how it is castellated in the planar dimensions. The mockup with the tile dimensions of 5 x 5 x 5 mm demonstrated best results during the HHF tests at EBTS facility (SNLA). Thermal response test demonstrated the ultimate heat flux level fo 16.6 MW/m 2 without failure of the joint, melting of the beryllium surface limited the level of the heat flux. During thousand cycles by heat flux density of 13.5 MW/m 2 no damages in the Be/CuCrZr joint occurred that was approved by metallographic investigation of the tested and non-tested cross-sections. This paper presents the results of HHF testing with Be-armoured mockup that has optimized armour geometry, 2-D temperature analysis for testing conditions and the results of metallographic analysis. The results are discussed and the recommendations for armour dimensions are also made. (orig.)

  7. Spearman's "law of diminishing returns" and the role of test reliability investigated in a large sample of Danish military draftees

    DEFF Research Database (Denmark)

    Teasdale, Thomas William; Hartmann, P.

    2005-01-01

    The present article investigates Spearman's "Law of Diminishing Returns" (SLODR), which hypothesizes that the g saturation for cognitive tests is lower for high ability subjects than for low ability subjects. This hypothesis was tested in a large sample of Danish military draftees (N = 6757) who...... were representative of the young adult male population, aged 18-19, and tested with a group-administered intelligence test comprised of four subtests. The aim of the study was twofold. The first was to reproduce previous SLODR findings by the present authors. This was done by replicating...... in reliability could account for the difference in g saturation across ability groups. The results showed that the reliability was larger for the High ability group, thereby not explaining the present findings....

  8. Reliability and construct validity of Yo-Yo tests in untrained and soccer-trained school-girls aged 9-16

    DEFF Research Database (Denmark)

    Póvoas, Susana C A; Castagna, Carlo; Soares, José Manuel da Costa

    2016-01-01

    Purpose: The reliability and construct validity of three age-adapted-intensity Yo-Yo tests were evaluated in untrained (n=67) vs. soccer-trained (n=65) 9-16-year-old school-girls. Methods: Tests were performed 7 days apart for reliability (9-11-year-old: Yo-Yo intermittent recovery level 1 children...... during test and retest. Conclusion: The Yo-Yo tests are reliable for determining intermittent-exercise capacity and %HRpeak for soccer players and untrained 9-16-year-old girls. They also possess construct validity with better performances for soccer players compared to untrained age-matched girls...

  9. A reliability as an independent variable (RAIV) methodology for optimizing test planning for liquid rocket engines

    Science.gov (United States)

    Strunz, Richard; Herrmann, Jeffrey W.

    2011-12-01

    The hot fire test strategy for liquid rocket engines has always been a concern of space industry and agency alike because no recognized standard exists. Previous hot fire test plans focused on the verification of performance requirements but did not explicitly include reliability as a dimensioning variable. The stakeholders are, however, concerned about a hot fire test strategy that balances reliability, schedule, and affordability. A multiple criteria test planning model is presented that provides a framework to optimize the hot fire test strategy with respect to stakeholder concerns. The Staged Combustion Rocket Engine Demonstrator, a program of the European Space Agency, is used as example to provide the quantitative answer to the claim that a reduced thrust scale demonstrator is cost beneficial for a subsequent flight engine development. Scalability aspects of major subsystems are considered in the prior information definition inside the Bayesian framework. The model is also applied to assess the impact of an increase of the demonstrated reliability level on schedule and affordability.

  10. Test–Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study

    Directory of Open Access Journals (Sweden)

    Clare E. Palmer

    2018-01-01

    Full Text Available Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington’s disease (HD and Parkinson’s disease (PD across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test–retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test–retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test–retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT from the combined-Simon-Stop-Signal task showed moderate test–retest reliability, however, the combined SSRT interference effect showed poor test–retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  11. A prototype tap test imaging system: Initial field test results

    Science.gov (United States)

    Peters, J. J.; Barnard, D. J.; Hudelson, N. A.; Simpson, T. S.; Hsu, D. K.

    2000-05-01

    This paper describes a simple, field-worthy tap test imaging system that gives quantitative information about the size, shape, and severity of defects and damages. The system consists of an accelerometer, electronic circuits for conditioning the signal and measuring the impact duration, a laptop PC and data acquisition and processing software. The images are generated manually by tapping on a grid printed on a plastic sheet laid over the part's surface. A mechanized scanner is currently under development. The prototype has produced images for a variety of aircraft composite and metal honeycomb structures containing flaws, damages, and repairs. Images of the local contact stiffness, deduced from the impact duration using a spring model, revealed quantitatively the stiffness reduction due to flaws and damages, as well as the stiffness enhancement due to substructures. The system has been field tested on commercial and military aircraft as well as rotor blades and engine decks on helicopters. Field test results will be shown and the operation of the system will be demonstrated.—This material is based upon work supported by the Federal Aviation Administration under Contract #DTFA03-98-D-00008, Delivery Order No. IA016 and performed at Iowa State University's Center for NDE as part of the Center for Aviation Systems Reliability program.

  12. Test-retest reliability of trunk motor variability measured by large-array surface electromyography.

    Science.gov (United States)

    Abboud, Jacques; Nougarou, François; Loranger, Michel; Descarreaux, Martin

    2015-01-01

    The objective of this study was to evaluate the test-retest reliability of the trunk muscle activity distribution in asymptomatic participants during muscle fatigue using large-array surface electromyography (EMG). Trunk muscle activity distribution was evaluated twice, with 3 to 4 days between them, in 27 asymptomatic volunteers using large-array surface EMG. Motor variability, assessed with 2 different variables (the centroid coordinates of the root mean square map and the dispersion variable), was evaluated during a low back muscle fatigue task. Test-retest reliability of muscle activity distribution was obtained using Pearson correlation coefficients. A shift in the distribution of EMG amplitude toward the lateral-caudal region of the lumbar erector spinae induced by muscle fatigue was observed. Moderate to very strong correlations were found between both sessions in the last 3 phases of the fatigue task for both motor variability variables, whereas weak to moderate correlations were found in the first phases of the fatigue task only for the dispersion variable. These findings show that, in asymptomatic participants, patterns of EMG activity are less reliable in initial stages of muscle fatigue, whereas later stages are characterized by highly reliable patterns of EMG activity. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  13. Improvement in reliability and accuracy of heater tube eddy current testing by integration with an appropriate destructive test

    International Nuclear Information System (INIS)

    Giovanelli, F.; Gabiccini, S.; Tarli, R.; Motta, P.

    1988-01-01

    A specially developed destructive test is described showing how the reliability and accuracy of a non-destructive technique can be improved if it is suitably accompanied by an appropriate destructive test. The experiment was carried out on samples of AISI 304L tubes from the low-pressure (LP) preheaters of a BWR 900 MW nuclear plant. (author)

  14. Test-retest reliability and responsiveness of the Barthel Index-based Supplementary Scales in patients with stroke.

    Science.gov (United States)

    Lee, Ya-Chen; Yu, Wan-Hui; Hsueh, I-Ping; Chen, Sheng-Shiung; Hsieh, Ching-Lin

    2017-10-01

    A lack of evidence on the test-retest reliability and responsiveness limits the utility of the BI-based Supplementary Scales (BI-SS) in both clinical and research settings. To examine the test-retest reliability and responsiveness of the BI-based Supplementary Scales (BI-SS) in patients with stroke. A repeated-assessments design (1 week apart) was used to examine the test-retest reliability of the BI-SS. For the responsiveness study, the participants were assessed with the BI-SS and BI (treated as an external criterion) at admission to and discharge from rehabilitation wards. Seven outpatient rehabilitation units and one inpatient rehabilitation unit. Outpatients with chronic stroke. Eighty-four outpatients with chronic stroke participated in the test-retest reliability study. Fifty-seven inpatients completed baseline and follow-up assessments in the responsiveness study. For the test-retest reliability study, the values of the intra-class correlation coefficient and the overall percentage of minimal detectable change for the Ability Scale and Self-perceived Difficulty Scale were 0.97, 12.8%, and 0.78, 35.8%, respectively. For the responsiveness study, the standardized effect size and standardized response mean (representing internal responsiveness) of the Ability Scale and Self-perceived Difficulty Scale were 1.17 and 1.56, and 0.78 and 0.89, respectively. Regarding external responsiveness, the change in score of the Ability Scale had significant and moderate association with that of the BI (r=0.61, Ptest-retest reliability and sufficient responsiveness for patients with stroke. However, the Self-perceived Difficulty Scale of the BI-SS has substantial random measurement error and insufficient external responsiveness, which may affect its utility in clinical settings. The findings of this study provide empirical evidence of psychometric properties of the BI-SS for assessing ability and self-perceived difficulty of ADL in patients with stroke.

  15. Test-retest reliability of Eurofit Physical Fitness items for children with visual impairments

    NARCIS (Netherlands)

    Houwen, Suzanne; Visscher, Chris; Hartman, Esther; Lemmink, Koen A. P. M.

    The purpose of this study was to examine the test-retest reliability of physical fitness items from the European Test of Physical Fitness (Eurofit) for children with visual impairments. A sample of 21 children, ages 6-12 years, that were recruited from a special school for children with visual

  16. Reliability Verification of DBE Environment Simulation Test Facility by using Statistics Method

    International Nuclear Information System (INIS)

    Jang, Kyung Nam; Kim, Jong Soeg; Jeong, Sun Chul; Kyung Heum

    2011-01-01

    In the nuclear power plant, all the safety-related equipment including cables under the harsh environment should perform the equipment qualification (EQ) according to the IEEE std 323. There are three types of qualification methods including type testing, operating experience and analysis. In order to environmentally qualify the safety-related equipment using type testing method, not analysis or operation experience method, the representative sample of equipment, including interfaces, should be subjected to a series of tests. Among these tests, Design Basis Events (DBE) environment simulating test is the most important test. DBE simulation test is performed in DBE simulation test chamber according to the postulated DBE conditions including specified high-energy line break (HELB), loss of coolant accident (LOCA), main steam line break (MSLB) and etc, after thermal and radiation aging. Because most DBE conditions have 100% humidity condition, in order to trace temperature and pressure of DBE condition, high temperature steam should be used. During DBE simulation test, if high temperature steam under high pressure inject to the DBE test chamber, the temperature and pressure in test chamber rapidly increase over the target temperature. Therefore, the temperature and pressure in test chamber continue fluctuating during the DBE simulation test to meet target temperature and pressure. We should ensure fairness and accuracy of test result by confirming the performance of DBE environment simulation test facility. In this paper, in order to verify reliability of DBE environment simulation test facility, statistics method is used

  17. Demonstration test for reliability of valves for atomic power plants

    International Nuclear Information System (INIS)

    Hosaka, Shiro

    1978-01-01

    The demonstration test on the reliability of valves for atomic power plants being carried out by the Nuclear Engineering Test Center is reported. This test series is conducted as six-year project from FY 1976 to FY 1981 at the Isogo Test Center. The demonstration test consists of (1) environmental test, (2) reaction force test, (3) vibration test, (4) stress measurement test, (5) operational characteristic test, (6) flow resistance coefficient measuring test, (7) leakage test and (8) safety valve and relief valve test. These contents are explained about the special requirements for nuclear use, for example, the enviornmental condition after the design base accident of PWRs and BWRs, the environmental test sequence for isolation valves of containment vessels under the emergency condition, the seismic test condition for valves of nuclear use, the various stress measurements under thermal transient conditions, the leak test after 500 cycles between the normal operating conditions for PWRs and BWRs and the start up conditions and so on. As for the testing facilities, the whole flow diagram is shown, in which the environmental test section, the vibration test section, the steam test section, the hot water test section, the safety valve test section and main components are included. The specifications of each test section and main components are presented. (Nakai, Y.)

  18. The Persian version of phonological test of diagnostic evaluation articulation and phonology for Persian speaking children and investigating its validity and reliability

    Directory of Open Access Journals (Sweden)

    Talieh Zarifian

    2014-10-01

    Full Text Available Background and Aim: Speech and language pathologists (SLP often refer to phonological data as part of their assessment protocols in evaluating the communication skills of children. The aim of this study was to develop the Persian version of the phonological test in evaluating and diagnosing communication skills in Persian speaking children and to evaluate its validity and reliability.Methods: The Persian phonological test (PPT was conducted on 387 monolingual Persian speaking boys and girls (3-6 years of age who were selected from 12 nurseries in the northwest region of Tehran. Content validity ratio (CVR and content validity index (CVI were assessed by speechtherapists and linguists. Correlation between speech and language pathologists experts' opinions and Persian phonological test results in children with and without phonological disorders was evaluated to investigate the Persian phonological test validity. In addition, the Persian phonological test test-retest reliability was investigated.Results: Both content validity ratio and content validity index were found to be acceptable (CVR≥94.71 and CVI=97.35. The PPT validity was confirmed by finding a good correlation between s peech and language pathologists experts' opinions and Persian phonological test results ( r Kappa =0.73 and r Spearman =0.76. The percent of agreement between transcription and analyzing error patterns in test-retest (ranging from 86.27%-100% and score-rescore (ranging from 94.28%-100% showed that Persian phonological test had a very high reliability.Conclusion: The results of this study show that the Persian phonological test seems to be a suitable tool in evaluating phonological skills of Persian speaking children in clinical settings and research projects.

  19. Under sodium reliability tests on core components and in-core instrumentation

    International Nuclear Information System (INIS)

    Ruppert, E.; Stehle, H.; Vinzens, K.

    1977-01-01

    A sodium test facility for fast breeder core components (AKB), built by INTERATOM at Bensberg, has been operating since 1971 to test fuel dummies and blanket elements as well as absorber elements under simulated normal and extreme reactor conditions. Individual full-scale fuel or blanket elements and arrays of seven elements, modelling a section of the SNR-300 reactor core, have been tested under a wide range of sodium mass flow and isothermal test conditions up to 925K as well as under cyclic changed temperature transients. Besides endurance testing of the core components a special sodium and high-temperature instrumentation is provided to investigate thermohydraulic and vibrational behaviour of the test objects. During all test periods the main subassembly characteristics could be reproduced and the reliability of the instrumentation could be proven. (orig.) [de

  20. Development of a test rig and its application for validation and reliability testing of safety-critical software

    Energy Technology Data Exchange (ETDEWEB)

    Thai, N D; McDonald, A M [Atomic Energy of Canada Ltd., Mississauga, ON (Canada)

    1996-12-31

    This paper describes a versatile test rig developed by AECL for functional testing of safety-critical software used in the process trip computers of the Wolsong CANDU stations. The description covers the hardware and software aspects of the test rig, the test language and its interpreter, and other major testing software utilities such as the test oracle, sampler and profiler. The paper also discusses the application of the rig in the final stages of testing of the process trip computer software, namely validation and reliability tests. It shows how random test cases are generated, test scripts prepared and automatically run on the test rig. The versatility of the rig is further demonstrated in other types of testing such as sub-system tests, verification of the test oracle, testing of newly-developed test script, self-test and calibration. (author). 5 tabs., 10 figs.

  1. Development of a test rig and its application for validation and reliability testing of safety-critical software

    International Nuclear Information System (INIS)

    Thai, N.D.; McDonald, A.M.

    1995-01-01

    This paper describes a versatile test rig developed by AECL for functional testing of safety-critical software used in the process trip computers of the Wolsong CANDU stations. The description covers the hardware and software aspects of the test rig, the test language and its interpreter, and other major testing software utilities such as the test oracle, sampler and profiler. The paper also discusses the application of the rig in the final stages of testing of the process trip computer software, namely validation and reliability tests. It shows how random test cases are generated, test scripts prepared and automatically run on the test rig. The versatility of the rig is further demonstrated in other types of testing such as sub-system tests, verification of the test oracle, testing of newly-developed test script, self-test and calibration. (author). 5 tabs., 10 figs

  2. Reliability analysis of component of affination centrifugal 1 machine by using reliability engineering

    Science.gov (United States)

    Sembiring, N.; Ginting, E.; Darnello, T.

    2017-12-01

    Problems that appear in a company that produces refined sugar, the production floor has not reached the level of critical machine availability because it often suffered damage (breakdown). This results in a sudden loss of production time and production opportunities. This problem can be solved by Reliability Engineering method where the statistical approach to historical damage data is performed to see the pattern of the distribution. The method can provide a value of reliability, rate of damage, and availability level, of an machine during the maintenance time interval schedule. The result of distribution test to time inter-damage data (MTTF) flexible hose component is lognormal distribution while component of teflon cone lifthing is weibull distribution. While from distribution test to mean time of improvement (MTTR) flexible hose component is exponential distribution while component of teflon cone lifthing is weibull distribution. The actual results of the flexible hose component on the replacement schedule per 720 hours obtained reliability of 0.2451 and availability 0.9960. While on the critical components of teflon cone lifthing actual on the replacement schedule per 1944 hours obtained reliability of 0.4083 and availability 0.9927.

  3. Factors That Influence Standard Automated Perimetry Test Results in Glaucoma : Test Reliability, Technician Experience, Time of Day, and Season

    NARCIS (Netherlands)

    Montolio, Francisco G. Junoy; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M.

    2012-01-01

    PURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience,

  4. Factors that influence standard automated perimetry test results in glaucoma: Test reliability, technician experience, time of day, and season

    NARCIS (Netherlands)

    F.G.J. Montolio (Francisco G. Junoy); C. Wesselink (Christiaan); M.C.M. Gordijn (Marijke); N.M. Jansonius (Nomdo)

    2012-01-01

    textabstractPURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician

  5. Reliability of Strength Testing using the Advanced Resistive Exercise Device and Free Weights

    Science.gov (United States)

    English, Kirk L.; Loehr, James A.; Laughlin, Mitzi A.; Lee, Stuart M. C.; Hagan, R. Donald

    2008-01-01

    The Advanced Resistive Exercise Device (ARED) was developed for use on the International Space Station as a countermeasure against muscle atrophy and decreased strength. This investigation examined the reliability of one-repetition maximum (1RM) strength testing using ARED and traditional free weight (FW) exercise. Methods: Six males (180.8 +/- 4.3 cm, 83.6 +/- 6.4 kg, 36 +/- 8 y, mean +/- SD) who had not engaged in resistive exercise for at least six months volunteered to participate in this project. Subjects completed four 1RM testing sessions each for FW and ARED (eight total sessions) using a balanced, randomized, crossover design. All testing using one device was completed before progressing to the other. During each session, 1RM was measured for the squat, heel raise, and deadlift exercises. Generalizability (G) and intraclass correlation coefficients (ICC) were calculated for each exercise on each device and were used to predict the number of sessions needed to obtain a reliable 1RM measurement (G . 0.90). Interclass reliability coefficients and Pearson's correlation coefficients (R) also were calculated for the highest 1RM value (1RM9sub peak)) obtained for each exercise on each device to quantify 1RM relationships between devices.

  6. The Impact Analysis of Psychological Reliability of Population Pilot Study For Selection of Particular Reliable Multi-Choice Item Test in Foreign Language Research Work

    Directory of Open Access Journals (Sweden)

    Seyed Hossein Fazeli

    2010-10-01

    Full Text Available The purpose of research described in the current study is the psychological reliability, its’ importance, application, and more to investigate on the impact analysis of psychological reliability of population pilot study for selection of particular reliable multi-choice item test in foreign language research work. The population for subject recruitment was all under graduated students from second semester at large university in Iran (both male and female that study English as a compulsory paper. In Iran, English is taught as a foreign language.

  7. Danish VISA-A questionnaire with validation and reliability testing for Danish-speaking Achilles tendinopathy patients

    DEFF Research Database (Denmark)

    Iversen, J. V.; Bartels, E. M.; Jørgensen, J. E.

    2016-01-01

    The VISA-A questionnaire has proven to be a valid and reliable tool for assessing severity of Achilles tendinopathy (AT). The aim was to translate and cross-culturally adapt the VISA-A questionnaire for a Danish-speaking AT population, and subsequently perform validity and reliability tests...

  8. Reliability and validity of neurobehavioral function on the Psychology Experimental Building Language test battery in young adults.

    Science.gov (United States)

    Piper, Brian J; Mueller, Shane T; Geerken, Alexander R; Dixon, Kyle L; Kroliczak, Gregory; Olsen, Reid H J; Miller, Jeremy K

    2015-01-01

    Background. The Psychology Experiment Building Language (PEBL) software consists of over one-hundred computerized tests based on classic and novel cognitive neuropsychology and behavioral neurology measures. Although the PEBL tests are becoming more widely utilized, there is currently very limited information about the psychometric properties of these measures. Methods. Study I examined inter-relationships among nine PEBL tests including indices of motor-function (Pursuit Rotor and Dexterity), attention (Test of Attentional Vigilance and Time-Wall), working memory (Digit Span Forward), and executive-function (PEBL Trail Making Test, Berg/Wisconsin Card Sorting Test, Iowa Gambling Test, and Mental Rotation) in a normative sample (N = 189, ages 18-22). Study II evaluated test-retest reliability with a two-week interest interval between administrations in a separate sample (N = 79, ages 18-22). Results. Moderate intra-test, but low inter-test, correlations were observed and ceiling/floor effects were uncommon. Sex differences were identified on the Pursuit Rotor (Cohen's d = 0.89) and Mental Rotation (d = 0.31) tests. The correlation between the test and retest was high for tests of motor learning (Pursuit Rotor time on target r = .86) and attention (Test of Attentional Vigilance response time r = .79), intermediate for memory (digit span r = .63) but lower for the executive function indices (Wisconsin/Berg Card Sorting Test perseverative errors = .45, Tower of London moves = .15). Significant practice effects were identified on several indices of executive function. Conclusions. These results are broadly supportive of the reliability and validity of individual PEBL tests in this sample. These findings indicate that the freely downloadable, open-source PEBL battery (http://pebl.sourceforge.net) is a versatile research tool to study individual differences in neurocognitive performance.

  9. Reliability of specific physical examination tests for the diagnosis of shoulder pathologies: a systematic review and meta-analysis.

    Science.gov (United States)

    Lange, Toni; Matthijs, Omer; Jain, Nitin B; Schmitt, Jochen; Lützner, Jörg; Kopkow, Christian

    2017-03-01

    Shoulder pain in the general population is common and to identify the aetiology of shoulder pain, history, motion and muscle testing, and physical examination tests are usually performed. The aim of this systematic review was to summarise and evaluate intrarater and inter-rater reliability of physical examination tests in the diagnosis of shoulder pathologies. A comprehensive systematic literature search was conducted using MEDLINE, EMBASE, Allied and Complementary Medicine Database (AMED) and Physiotherapy Evidence Database (PEDro) through 20 March 2015. Methodological quality was assessed using the Quality Appraisal of Reliability Studies (QAREL) tool by 2 independent reviewers. The search strategy revealed 3259 articles, of which 18 finally met the inclusion criteria. These studies evaluated the reliability of 62 test and test variations used for the specific physical examination tests for the diagnosis of shoulder pathologies. Methodological quality ranged from 2 to 7 positive criteria of the 11 items of the QAREL tool. This review identified a lack of high-quality studies evaluating inter-rater as well as intrarater reliability of specific physical examination tests for the diagnosis of shoulder pathologies. In addition, reliability measures differed between included studies hindering proper cross-study comparisons. PROSPERO CRD42014009018. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Validity and reliability of the single-trial line drill test of anaerobic power in basketball players.

    Science.gov (United States)

    Fatouros, I G; Laparidis, K; Kambas, A; Chatzinikolaou, A; Techlikidou, E; Katrabasas, I; Douroudos, I; Leontsini, D; Berberidou, F; Draganidis, D; Christoforidis, C; Tsoukas, D; Kelis, S; Taxildaris, K

    2011-03-01

    This study evaluated the validity, reliability, and sensitivity of the single-trial line drill test (SLDT) for anaerobic power assessment. Twenty-four volunteers were assigned to either a control (C, N.=12) or an experimental (BP, N.=12 basketball players) group. SLDT's (time-to-complete) concurrent validity was evaluated against the Wingate testing (WAnT: mean [MP] and peak power [PP]) and a 30-sec vertical jump testing test (VJT: mean height and MP). Blood lactate concentration was measured at rest and immediately post-test. SLDT's reliability [test-retest intraclass correlation coefficients (ICC), coefficient of variation (CV), Bland-Altman plots] and sensitivity were determined (one-way ANOVA). Kendall's tau correlation analysis revealed correlations (Pbasketball players.

  11. Systems reliability/structural reliability

    International Nuclear Information System (INIS)

    Green, A.E.

    1980-01-01

    The question of reliability technology using quantified techniques is considered for systems and structures. Systems reliability analysis has progressed to a viable and proven methodology whereas this has yet to be fully achieved for large scale structures. Structural loading variants over the half-time of the plant are considered to be more difficult to analyse than for systems, even though a relatively crude model may be a necessary starting point. Various reliability characteristics and environmental conditions are considered which enter this problem. The rare event situation is briefly mentioned together with aspects of proof testing and normal and upset loading conditions. (orig.)

  12. Accelerated life testing and reliability of high K multilayer ceramic capacitors

    Science.gov (United States)

    Minford, W. J.

    1981-01-01

    The reliability of one lot of high K multilayer ceramic capacitors was evaluated using accelerated life testing. The degradation in insulation resistance was characterized as a function of voltage and temperature. The times to failure at a voltage-temperature stress conformed to a lognormal distribution with a standard deviation approximately 0.5.

  13. Reliability and validity of neurobehavioral function on the Psychology Experimental Building Language test battery in young adults

    Directory of Open Access Journals (Sweden)

    Brian J. Piper

    2015-12-01

    Full Text Available Background. The Psychology Experiment Building Language (PEBL software consists of over one-hundred computerized tests based on classic and novel cognitive neuropsychology and behavioral neurology measures. Although the PEBL tests are becoming more widely utilized, there is currently very limited information about the psychometric properties of these measures.Methods. Study I examined inter-relationships among nine PEBL tests including indices of motor-function (Pursuit Rotor and Dexterity, attention (Test of Attentional Vigilance and Time-Wall, working memory (Digit Span Forward, and executive-function (PEBL Trail Making Test, Berg/Wisconsin Card Sorting Test, Iowa Gambling Test, and Mental Rotation in a normative sample (N = 189, ages 18–22. Study II evaluated test–retest reliability with a two-week interest interval between administrations in a separate sample (N = 79, ages 18–22.Results. Moderate intra-test, but low inter-test, correlations were observed and ceiling/floor effects were uncommon. Sex differences were identified on the Pursuit Rotor (Cohen’s d = 0.89 and Mental Rotation (d = 0.31 tests. The correlation between the test and retest was high for tests of motor learning (Pursuit Rotor time on target r = .86 and attention (Test of Attentional Vigilance response time r = .79, intermediate for memory (digit span r = .63 but lower for the executive function indices (Wisconsin/Berg Card Sorting Test perseverative errors = .45, Tower of London moves = .15. Significant practice effects were identified on several indices of executive function.Conclusions. These results are broadly supportive of the reliability and validity of individual PEBL tests in this sample. These findings indicate that the freely downloadable, open-source PEBL battery (http://pebl.sourceforge.net is a versatile research tool to study individual differences in neurocognitive performance.

  14. Influence of test reliability on the screening performance of frequency-doubling perimetry

    NARCIS (Netherlands)

    Heeg, GP; Jansonius, NM

    PURPOSE: To investigate the influence of test reliability on the screening performance of frequency,doubling perimetry (FDT). DESIGN: Cross-sectional study. METHODS: FDT sensitivity and specificity were calculated three times using three different strategies for handling unreliable (that is, > 0

  15. Comparison of RPR 'teardrop' card test, VDRL and FTA-ABS tests results on sera from persons with suspected yaws in Columbia.

    Science.gov (United States)

    Hopkins, D R; Florez, D

    1977-08-01

    A small study comparing results of the rapid plasma reagin (RPR) teardrop card test performed in the field, with results of Venereal Disease Research Laboratory (VDRL) and fluorescent treponemal antibody absorption (FTA-ABS) tests performed in the laboratory on venous blood specimens from the same suspected yaws patients was undertaken in Columbia in July 1975. The results suggest that the RPR teardrop card test may be used to screen for infectious, or potentially infectious, yaws patients under field conditions, but that it will not reliably detect patients with VDRL titres of 1:2 or less, or all patients in whom sera are reactive in the FTA-ABS test.

  16. Test of gross motor development-2 for Filipino children with intellectual disability: validity and reliability.

    Science.gov (United States)

    Capio, Catherine M; Eguia, Kathlynne F; Simons, Johan

    2016-01-01

    This study aimed to examine aspects of validity and reliability of the Test of Gross Motor Development-2 (TGMD-2) in Filipino children with intellectual disability. Content and construct validity were verified, as well as inter-rater and intra-rater reliability. Two paediatric physiotherapists tested 81 children with intellectual disability (mean age = 9.29 ± 2.71 years) on locomotor and object control skills. Analysis of covariance, confirmatory factor analysis and analysis of variance were used to test validity, while Cronbach's alpha, intra-class correlation coefficients (ICC) and Bland-Altman plots were used to examine reliability. Age was a significant predictor of locomotor and object control scores (P = 0.004). The data fit the hypothesised two-factor model with fit indices as follows: χ(2) = 33.525, DF = 34, P = 0.491, χ(2)/DF = 0.986. As hypothesised, gender was a significant predictor for object control skills (P = 0.038). Participants' mean scores were significantly below mastery (locomotor, P intellectual disability.

  17. The Screening Test for Emotional Problems-Parent Report (STEP-P): Studies of Reliability and Validity

    Science.gov (United States)

    Erford, Bradley T.; Alsamadi, Silvana C.

    2012-01-01

    Score reliability and validity of parent responses concerning their 10- to 17-year-old students were analyzed using the Screening Test for Emotional Problems-Parent Report (STEP-P), which assesses a variety of emotional problems classified under the Individuals with Disabilities Education Improvement Act. Score reliability, convergent, and…

  18. Materials of large wind turbine blades: Recent results in testing and modeling

    DEFF Research Database (Denmark)

    Mishnaevsky, Leon; Brøndsted, Povl; Nijssen, Rogier

    2012-01-01

    The reliability of rotor blades is the pre-condition for the development and wide use of large wind turbines. In order to accurately predict and improve the wind turbine blade behavior, three main aspects of the reliability and strength of rotor blades were considered: (i) development of methods...... of the effect of the microstructure of wind turbine blade composites on their strength and ways of microstructural optimization of the materials. By testing reference coupons, the effect of testing parameters (temperature and frequency) on the lifetime of blade composites was investigated, and the input data...... clustering, misalignments, interface properties and other factors on the strength and lifetime of the wind turbine blade materials were investigated in the micromechanical finite element simulations. The results described in this paper stem from the Rotor Structure and Materials task of the UPWIND project...

  19. The reliability and validity of the standardized Mensendieck test in relation to disability in patients with chronic pain.

    Science.gov (United States)

    Keessen, Paul; Maaskant, Jolanda; Visser, Bart

    2018-08-01

    The standardized Mensendieck test (SMT) was developed to quantify posture, movement, gait, and respiration. In the hands of an experienced therapist, the SMT is proven to be a reliable tool. It is unclear whether posture, movement, gait, and respiration are related to the degree of functional disability in patients with chronic pain. The objective of this study was to assess the reliability and convergent validity of the SMT in a heterogeneous sample of 50 patients with chronic pain. Internal consistency was determined by Cronbach's α and interrater reliability by the intraclass correlation coefficient (ICC). Convergent validity was assessed by determining the Spearman rank correlation coefficient between the movement quality measured in the SMT and functional limitation measured on the disability rating index (DRI). The internal consistency was Cronbach's α 0.91. Substantial reliability was found for the items: movement (ICC = 0.68), gait (ICC = 0.69), sitting posture (ICC = 0.63), and respiration (ICC = 0.64). Insufficient reliability was found for standing posture (ICC = 0.23). A moderate correlation was found between average test score SMT and the DRI (r = -0.37) and respiration and DRI (r = -0.45). The SMT is a reasonably reliable tool to assess movement, gait, sitting posture, and respiration. None of the items in the domain standing posture has sufficient reliability. A thorough study of this domain should be considered. The results show little evidence for convergent validity. Several items of the SMT correlated moderately with functional limitation with the DRI. These items were global movement, hip flexion, pelvis rotation, and all respiration items.

  20. Development of Chinese Military Personnel Social Support Scale and tests for its reliability and validity

    Directory of Open Access Journals (Sweden)

    Kai-hong TANG

    2013-01-01

    Full Text Available Objective  To develop Chinese Military Personnel Social Support Scaleand verify its reliability and validity. Methods  The Chinese Military Personnel Social Support Scalewas initiated, organized and compiled based upon open-ended questionnaire survey done in a systematic manner, and previous researches were taken as references. A total of 630 military personnel were chosen by random cluster sampling and tested with the Scale, among them 50 were tested with Social Support Rating Scale(SSRS and Chinese Military Psychosomatic Health Scale(CMPHS simultaneously, and the test was done solely a second time with CMPHS 2 weeks later. The reliability and validity were assessed and verified by exploratory factor analysis, confirmatory factor analysis and correlation analysis. Results  The Chinese Military Personnel Social Support Scalecomprised three factors, namely subjective support, objective support and utility of social support. Eighteen items were left in official scale after amendment by factor analysis, and one lying subscale was added. The correlation coefficients between the public factors ranged from 0.477 to 0.589 (P<0.01, and the correlation coefficients between factors and total scale ranged from 0.721 to 0.823 (P<0.01. The test-retest correlation coefficients of total scale and subscales ranged from 0.622 to 0.803 (P<0.01, the Cronbach α coefficients ranged from 0.624 to 0.874, and the split-half correlation coefficients ranged from 0.551 to 0.828. Significant correlation existed between this Scale and two criterion scales, namely SSRS and CMPHS. Conclusion  It is verified that the Chinese Military Personnel Social Support Scalehas excellent reliability and validity, and complying with psychometric standards, it may be used to evaluate the social support level of Chinese military personnel.

  1. Influence of previous experience on resistance training on reliability of one-repetition maximum test.

    Science.gov (United States)

    Ritti-Dias, Raphael Mendes; Avelar, Ademar; Salvador, Emanuel Péricles; Cyrino, Edilson Serpeloni

    2011-05-01

    The 1-repetition maximum test (1RM) has been widely used to assess maximal strength. However, to improve accuracy in assessing maximal strength, several sessions of the 1RM test are recommended. The aim of this study was to analyze the influence of previous resistance training experience on the reliability of 1RM test. Thirty men were assigned to the following 2 groups according to their previous resistance training experience: no previous resistance training experience (NOEXP) and more than 24 months of resistance training experience (EXP). All subjects performed the 1RM tests in bench press and squat in 4 sessions on distinct days. There was a significant session × group effect in bench press (F = 3.09; p reliability of the 1RM test is influenced by the subject's previous experience in resistance training. Subjects without experience in resistance training require more practice and familiarization and show greater increases in maximal strength between sessions than subjects with previous experience in resistance training.

  2. Analysis and Application of Reliability

    International Nuclear Information System (INIS)

    Jeong, Hae Seong; Park, Dong Ho; Kim, Jae Ju

    1999-05-01

    This book tells of analysis and application of reliability, which includes definition, importance and historical background of reliability, function of reliability and failure rate, life distribution and assumption of reliability, reliability of unrepaired system, reliability of repairable system, sampling test of reliability, failure analysis like failure analysis by FEMA and FTA, and cases, accelerated life testing such as basic conception, acceleration and acceleration factor, and analysis of accelerated life testing data, maintenance policy about alternation and inspection.

  3. The reliability of sickling and solubility tests and peripheral blood ...

    African Journals Online (AJOL)

    The reliability of sickling and solubility tests and peripheral blood film method for sickle cell disease screening at district health centers in Uganda. ... Les 200 prélèvements des enfants ages de 6 mois à 5 ans ont été analysés de façon indépendante en utilisant la méthode des analyses d'hématies falciformes, la solubilité et ...

  4. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    Science.gov (United States)

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  5. Test-retest reliability and minimal detectable change of two simplified 3-point balance measures in patients with stroke.

    Science.gov (United States)

    Chen, Yi-Miau; Huang, Yi-Jing; Huang, Chien-Yu; Lin, Gong-Hong; Liaw, Lih-Jiun; Lee, Shih-Chieh; Hsieh, Ching-Lin

    2017-10-01

    The 3-point Berg Balance Scale (BBS-3P) and 3-point Postural Assessment Scale for Stroke Patients (PASS-3P) were simplified from the BBS and PASS to overcome the complex scoring systems. The BBS-3P and PASS-3P were more feasible in busy clinical practice and showed similarly sound validity and responsiveness to the original measures. However, the reliability of the BBS-3P and PASS-3P is unknown limiting their utility and the interpretability of scores. We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BBS-3P and PASS-3P in patients with stroke. Cross-sectional study. The rehabilitation departments of a medical center and a community hospital. A total of 51 chronic stroke patients (64.7% male). Both balance measures were administered twice 7 days apart. The test-retest reliability of both the BBS-3P and PASS-3P were examined by intraclass correlation coefficients (ICC). The MDC and its percentage over the total score (MDC%) of each measure was calculated for examining the random measurement errors. The ICC values of the BBS-3P and PASS-3P were 0.99 and 0.97, respectively. The MDC% (MDC) of the BBS-3P and PASS-3P were 9.1% (5.1 points) and 8.4% (3.0 points), respectively, indicating that both measures had small and acceptable random measurement errors. Our results showed that both the BBS-3P and the PASS-3P had good test-retest reliability, with small and acceptable random measurement error. These two simplified 3-level balance measures can provide reliable results over time. Our findings support the repeated administration of the BBS-3P and PASS-3P to monitor the balance of patients with stroke. The MDC values can help clinicians and researchers interpret the change scores more precisely.

  6. Test-retest reliability of an fMRI paradigm for studies of cardiovascular reactivity.

    Science.gov (United States)

    Sheu, Lei K; Jennings, J Richard; Gianaros, Peter J

    2012-07-01

    We examined the reliability of measures of fMRI, subjective, and cardiovascular reactions to standardized versions of a Stroop color-word task and a multisource interference task. A sample of 14 men and 12 women (30-49 years old) completed the tasks on two occasions, separated by a median of 88 days. The reliability of fMRI BOLD signal changes in brain areas engaged by the tasks was moderate, and aggregating fMRI BOLD signal changes across the tasks improved test-retest reliability metrics. These metrics included voxel-wise intraclass correlation coefficients (ICCs) and overlap ratio statistics. Task-aggregated ratings of subjective arousal, valence, and control, as well as cardiovascular reactions evoked by the tasks showed ICCs of 0.57 to 0.87 (ps reliability. These findings support using these tasks as a battery for fMRI studies of cardiovascular reactivity. Copyright © 2012 Society for Psychophysiological Research.

  7. Criterion validity and reliability of a smartphone delivered sub-maximal fitness test for people with type 2 diabetes

    DEFF Research Database (Denmark)

    Brinklov, Cecilie Fau; Thorsen, Ida Kær; Karstoft, Kristian

    2016-01-01

    Background: Prevention of multi-morbidities following non-communicable diseases requires a systematic registration of adverse modifiable risk factors, including low physical fitness. The aim of the study was to establish criterion validity and reliability of a smartphone app (InterWalk) delivered....... The algorithm was validated using leave-one-out cross validation. Test-retest reliability was tested in a subset of participants (N = 10). Results: The overall VO2peak prediction of the algorithm (R2) was 0.60 and 0.45 when the smartphone was placed in the pockets of the pants and jacket, respectively (p ... calorimetry and the acceleration (vector magnitude) from the smartphone was obtained. The vector magnitude was used to predict VO2peak along with the co-variates weight, height and sex. The validity of the algorithm was tested when the smartphone was placed in the right pocket of the pants or jacket...

  8. How reliable must advanced nondestructive testing be? A concept for the prediction, validation and raised quality of NDT

    International Nuclear Information System (INIS)

    Nockemann, C.; Tillack, G.R.; Schnitger, D.; Heidt, H.

    1995-01-01

    A concept of the harmonic integration of the following three mainstays of the reliability of ndt is proposed: 1. Theoretical prediction of the reliability as a function of physical parameter by computer modelling of the test problem concerned and the ndt process; maximisation by variation of the parameters. 2. Experimental evaluation of the reliability of ndt processes by the application of statistical methods to test practice. 3. Increasing the reliability by the combination of several ndt methods in a standard DV environment and European interconnection and provision of a distributed databank system. International exchange of experience via telecommunication. (orig.) [de

  9. Inter-Rater Reliability and Validity of the Australian Football League’s Kicking and Handball Tests

    Science.gov (United States)

    Cripps, Ashley J.; Hopper, Luke S.; Joyce, Christopher

    2015-01-01

    Talent identification tests used at the Australian Football League’s National Draft Combine assess the capacities of athletes to compete at a professional level. Tests created for the National Draft Combine are also commonly used for talent identification and athlete development in development pathways. The skills tests created by the Australian Football League required players to either handball (striking the ball with the hand) or kick to a series of 6 randomly generated targets. Assessors subjectively rate each skill execution giving a 0-5 score for each disposal. This study aimed to investigate the inter-rater reliability and validity of the skills tests at an adolescent sub-elite level. Male Australian footballers were recruited from sub-elite adolescent teams (n = 121, age = 15.7 ± 0.3 years, height = 1.77 ± 0.07 m, mass = 69.17 ± 8.08 kg). The coaches (n = 7) of each team were also recruited. Inter-rater reliability was assessed using Inter-class correlations (ICC) and Limits of Agreement statistics. Both the kicking (ICC = 0.96, p handball tests (ICC = 0.89, p handball test. Key points The skill tests created by the AFL demonstrated acceptable levels of relative and absolute inter-rater reliability. Both the AFL’s skills tests are able to differentiate between athletes dominant and non-dominant limbs. However, only the kicking test could consistently differentiated between score outcomes over a range of Australian Football specific disposal distances. Both tests demonstrated poor concurrent validity, with no correlation found between coaches’ perceptions of technical skills and actual skill outcomes measured. PMID:26336356

  10. A reliability analysis of the revised competitiveness index.

    Science.gov (United States)

    Harris, Paul B; Houston, John M

    2010-06-01

    This study examined the reliability of the Revised Competitiveness Index by investigating the test-retest reliability, interitem reliability, and factor structure of the measure based on a sample of 280 undergraduates (200 women, 80 men) ranging in age from 18 to 28 years (M = 20.1, SD = 2.1). The findings indicate that the Revised Competitiveness Index has high test-retest reliability, high inter-item reliability, and a stable factor structure. The results support the assertion that the Revised Competitiveness Index assesses competitiveness as a stable trait rather than a dynamic state.

  11. Intra- and inter-rater reliability of the Sollerman hand function test in patients with chronic stroke

    DEFF Research Database (Denmark)

    Brogårdh, Christina; Persson, Ann L; Sjölund, Bengt H

    2007-01-01

    PURPOSE: To examine whether the Sollerman hand function test is reliable in a test-retest situation in patients with chronic stroke. METHOD: Three independent examiners observed each patient at three experimental sessions; two days in week 1 (short-term test-retest) and one day in week 4 (long...... test seems to be a reliable test in patients with chronic stroke, but we recommend that the same examiner evaluates a patient's hand function pre- and post-treatment.......-term test-retest). A total of 24 patients with chronic stroke (mean age; 59.7 years, mean time since stroke onset 29.6 months) participated. The examiners simultaneously assessed the patients' ability to perform 20 subtests. Both ordinal data (generalized kappa) and total sum scores (Spearman's rank...

  12. Clinical Functional Capacity Testing in Patients With Facioscapulohumeral Muscular Dystrophy: Construct Validity and Interrater Reliability of Antigravity Tests

    NARCIS (Netherlands)

    Rijken, N.H.M.; Engelen, B.G.M. van; Weerdesteyn, V.G.M.; Geurts, A.C.H.

    2015-01-01

    OBJECTIVE: To evaluate the construct validity and interrater reliability of 4 simple antigravity tests in a small group of patients with facioscapulohumeral muscular dystrophy (FSHD). DESIGN: Case-control study. SETTING: University medical center. PARTICIPANTS: Patients with various severity levels

  13. Friction and wear in liquid-metal systems: comparability problems of test results obtained from different test facilities

    International Nuclear Information System (INIS)

    Wild, E.; Mack, K.J.

    1976-01-01

    Operational induced relative movements take place between contacting components in the core region of sodium cooled reactors. To ensure reliable long term functioning of such friction loaded components, materials are needed with good sliding properties and high wear resistance. Therefore, tribological properties of material combinations in liquid metal have been investigated experimentally for many years at various research establishments. However, despite identical boundary conditions, the comparison of results published does not yield a satisfactory agreement. The cause must be seen in the individual design and concept of the test sections used. This discrepancy was investigated. The results show that the elasticity, mass movement, and relative motion characteristic to the system prove to be the most important criteria influencing the test results

  14. The Persian version of auditory word discrimination test (P-AWDT) for children: Development, validity, and reliability.

    Science.gov (United States)

    Hashemi, Nassim; Ghorbani, Ali; Soleymani, Zahra; Kamali, Mohmmad; Ahmadi, Zohreh Ziatabar; Mahmoudian, Saeid

    2018-07-01

    Auditory discrimination of speech sounds is an important perceptual ability and a precursor to the acquisition of language. Auditory information is at least partially necessary for the acquisition and organization of phonological rules. There are few standardized behavioral tests to evaluate phonemic distinctive features in children with or without speech and language disorders. The main objective of the present study was the development, validity, and reliability of the Persian version of auditory word discrimination test (P-AWDT) for 4-8-year-old children. A total of 120 typical children and 40 children with speech sound disorder (SSD) participated in the present study. The test comprised of 160 monosyllabic paired-words distributed in the Forms A-1 and the Form A-2 for the initial consonants (80 words) and the Forms B-1 and the Form B-2 for the final consonants (80 words). Moreover, the discrimination of vowels was randomly included in all forms. Content validity was calculated and 50 children repeated the test twice with two weeks of interval (test-retest reliability). Further analysis was also implemented including validity, intraclass correlation coefficient (ICC), Cronbach's alpha (internal consistency), age groups, and gender. The content validity index (CVI) and the test-retest reliability of the P-AWDT were achieved 63%-86% and 81%-96%, respectively. Moreover, the total Cronbach's alpha for the internal consistency was estimated relatively high (0.93). Comparison of the mean scores of the P-AWDT in the typical children and the children with SSD revealed a significant difference. The results revealed that the group with SSD had greater severity of deficit than the typical group in auditory word discrimination. In addition, the difference between the age groups was statistically significant, especially in 4-4.11-year-old children. The performance of the two gender groups was relatively same. The comparison of the P-AWDT scores between the typical children

  15. Emotional-volitional components of operator reliability. [sensorimotor function testing under stress

    Science.gov (United States)

    Mileryan, Y. A.

    1975-01-01

    Sensorimotor function testing in a tracking task under stressfull working conditions established a psychological characterization for a successful aviation pilot: Motivation significantly increased the reliability and effectiveness of their work. Their acitivities were aimed at suppressing weariness and the feeling of fear caused by the stress factors; they showed patience, endurance, persistence, and a capacity for lengthy volitional efforts.

  16. Accelerated stress testing of thin film solar cells: Development of test methods and preliminary results

    Science.gov (United States)

    Lathrop, J. W.

    1985-01-01

    If thin film cells are to be considered a viable option for terrestrial power generation their reliability attributes will need to be explored and confidence in their stability obtained through accelerated testing. Development of a thin film accelerated test program will be more difficult than was the case for crystalline cells because of the monolithic construction nature of the cells. Specially constructed test samples will need to be fabricated, requiring committment to the concept of accelerated testing by the manufacturers. A new test schedule appropriate to thin film cells will need to be developed which will be different from that used in connection with crystalline cells. Preliminary work has been started to seek thin film schedule variations to two of the simplest tests: unbiased temperature and unbiased temperature humidity. Still to be examined are tests which involve the passage of current during temperature and/or humidity stress, either by biasing in the forward (or reverse) directions or by the application of light during stress. Investigation of these current (voltage) accelerated tests will involve development of methods of reliably contacting the thin conductive films during stress.

  17. Test-retest reliability and minimal detectable change scores for sit-to-stand-to-sit tests, the six-minute walk test, the one-leg heel-rise test, and handgrip strength in people undergoing hemodialysis.

    Science.gov (United States)

    Segura-Ortí, Eva; Martínez-Olmos, Francisco José

    2011-08-01

    Determining the relative and absolute reliability of outcomes of physical performance tests for people undergoing hemodialysis is necessary to discriminate between the true effects of exercise interventions and the inherent variability of this cohort. The aims of this study were to assess the relative reliability of sit-to-stand-to-sit tests (the STS-10, which measures the time [in seconds] required to complete 10 full stands from a sitting position, and the STS-60, which measures the number of repetitions achieved in 60 seconds), the Six-Minute Walk Test (6MWT), the one-leg heel-rise test, and the handgrip strength test and to calculate minimal detectable change (MDC) scores in people undergoing hemodialysis. This study was a prospective, nonexperimental investigation. Thirty-nine people undergoing hemodialysis at 2 clinics in Spain were contacted. Study participants performed the STS-10 (n=37), the STS-60 (n=37), and the 6MWT (n=36). At one of the settings, the participants also performed the one-leg heel-rise test (n=21) and the handgrip strength test (n=12) on both the right and the left sides. Participants attended 2 testing sessions 1 to 2 weeks apart. High intraclass correlation coefficients (≥.88) were found for all tests, suggesting good relative reliability. The MDC scores at 90% confidence intervals were as follows: 8.4 seconds for the STS-10, 4 repetitions for the STS-60, 66.3 m for the 6MWT, 3.4 kg for handgrip strength (force-generating capacity), 3.7 repetitions for the one-leg heel-rise test with the right leg, and 5.2 repetitions for the one-leg heel-rise test with the left leg. Limitations A limited sample of patients was used in this study. The STS-16, STS-60, 6MWT, one-leg heel rise test, and handgrip strength test are reliable outcome measures. The MDC scores at 90% confidence intervals for these tests will help to determine whether a change is due to error or to an intervention.

  18. Test-retest reliability of the diagnosis of schizoaffective disorder in childhood and adolescence - A systematic review and meta-analysis.

    Science.gov (United States)

    Salamon, Sarah; Santelmann, Hanno; Franklin, Jeremy; Baethge, Christopher

    2018-04-01

    Reliability of schizoaffective disorder (SAD) diagnoses is low in adults but unclear in children and adolescents (CAD). We estimate the test-retest reliability of SAD and its key differential diagnoses (schizophrenia, bipolar disorder, and unipolar depression). Systematic literature search of Medline, Embase, and PsycInfo for studies on test-retest reliability of SAD, in CAD. Cohen's kappa was extracted from studies. We performed meta-analysis for kappa, including subgroup and sensitivity analysis (PROSPERO protocol: CRD42013006713). Out of > 4000 records screened, seven studies were included. We estimated kappa values of 0.27 [95%-CI: 0.07 0.47] for SAD, 0.56 [0.29; 0.83] for schizophrenia, 0.64 [0.55; 0.74] for bipolar disorder, and 0.66 [0.52; 0.81] for unipolar depression. In 5/7 studies kappa of SAD was lower than that of schizophrenia; similar trends emerged for bipolar disorder (4/5) and unipolar depression (2/3). Estimates of positive agreement of SAD diagnoses supported these results. The number of studies and patients included is low. The point-estimate of the test-retest reliability of schizoaffective disorder is only fair, and lower than that of its main differential diagnoses. All kappa values under study were lower in children and adolescents samples than those reported for adults. Clinically, schizoaffective disorder should be diagnosed in strict adherence to the operationalized criteria and ought to be re-evaluated regularly. Should larger studies confirm the insufficient reliability of schizoaffective disorder in children and adolescents, the clinical value of the diagnosis is highly doubtful. Copyright © 2017. Published by Elsevier B.V.

  19. Factor Structure and Reliability of Test Items for Saudi Teacher Licence Assessment

    Science.gov (United States)

    Alsadaawi, Abdullah Saleh

    2017-01-01

    The Saudi National Assessment Centre administers the Computer Science Teacher Test for teacher certification. The aim of this study is to explore gender differences in candidates' scores, and investigate dimensionality, reliability, and differential item functioning using confirmatory factor analysis and item response theory. The confirmatory…

  20. Reliable test for prenatal prediction of fetal RhD type using maternal plasma from RhD negative women

    DEFF Research Database (Denmark)

    Clausen, Frederik Banch; Krog, Grethe Risum; Rieneck, Klaus

    2005-01-01

    The objective of this study was to establish a reliable test for prenatal prediction of fetal RhD type using maternal plasma from RhD negative women. This test is needed for future prenatal Rh prophylaxis.......The objective of this study was to establish a reliable test for prenatal prediction of fetal RhD type using maternal plasma from RhD negative women. This test is needed for future prenatal Rh prophylaxis....