WorldWideScience

Sample records for reliability test results

  1. Reliability Estimation Based Upon Test Plan Results

    National Research Council Canada - National Science Library

    Read, Robert

    1997-01-01

    The report contains a brief summary of aspects of the Maximus reliability point and interval estimation technique as it has been applied to the reliability of a device whose surveillance tests contain...

  2. Online cognition : Factors facilitating reliable online neuropsychological test results

    NARCIS (Netherlands)

    Feenstra, H.E.M.; Vermeulen, I.E.; Murre, J.M.J.; Schagen, S.B.

    2017-01-01

    OBJECTIVE: Online neuropsychological test batteries could allow for large-scale cognitive data collection in clinical studies. However, the few online neuropsychological test batteries that are currently available often still require supervision or lack proper psychometric evaluation. In this paper,

  3. Online cognition : factors facilitating reliable online neuropsychological test results

    NARCIS (Netherlands)

    Feenstra, Heleen E M; Vermeulen, Ivar E; Murre, Jaap M J; Schagen, Sanne B

    OBJECTIVE: Online neuropsychological test batteries could allow for large-scale cognitive data collection in clinical studies. However, the few online neuropsychological test batteries that are currently available often still require supervision or lack proper psychometric evaluation. In this paper,

  4. Test results of reliable and very high capillary multi-evaporators / condenser loop

    Energy Technology Data Exchange (ETDEWEB)

    Van Oost, S; Dubois, M; Bekaert, G [Societe Anonyme Belge de Construction Aeronautique - SABCA (Belgium)

    1997-12-31

    The paper present the results of various SABCA activities in the field of two-phase heat transport system. These results have been based on a critical review and analysis of the existing two-phase loop and of the future loop needs in space applications. The research and the development of a high capillary wick (capillary pressure up to 38 000 Pa) are described. These activities have led towards the development of a reliable high performance capillary loop concept (HPCPL), which is discussed in details. Several loop configurations mono/multi-evaporators have been ground tested. The presented results of various tests clearly show the viability of this concept for future applications. Proposed flight demonstrations as well as potential applications conclude this paper. (authors) 7 refs.

  5. Test results of reliable and very high capillary multi-evaporators / condenser loop

    Energy Technology Data Exchange (ETDEWEB)

    Van Oost, S.; Dubois, M.; Bekaert, G. [Societe Anonyme Belge de Construction Aeronautique - SABCA (Belgium)

    1996-12-31

    The paper present the results of various SABCA activities in the field of two-phase heat transport system. These results have been based on a critical review and analysis of the existing two-phase loop and of the future loop needs in space applications. The research and the development of a high capillary wick (capillary pressure up to 38 000 Pa) are described. These activities have led towards the development of a reliable high performance capillary loop concept (HPCPL), which is discussed in details. Several loop configurations mono/multi-evaporators have been ground tested. The presented results of various tests clearly show the viability of this concept for future applications. Proposed flight demonstrations as well as potential applications conclude this paper. (authors) 7 refs.

  6. Proof tests on reliability

    International Nuclear Information System (INIS)

    Mishima, Yoshitsugu

    1983-01-01

    In order to obtain public understanding on nuclear power plants, tests should be carried out to prove the reliability and safety of present LWR plants. For example, the aseismicity of nuclear power plants must be verified by using a large scale earthquake simulator. Reliability test began in fiscal 1975, and the proof tests on steam generators and on PWR support and flexure pins against stress corrosion cracking have already been completed, and the results have been internationally highly appreciated. The capacity factor of the nuclear power plant operation in Japan rose to 80% in the summer of 1983, and considering the period of regular inspection, it means the operation of almost full capacity. Japanese LWR technology has now risen to the top place in the world after having overcome the defects. The significance of the reliability test is to secure the functioning till the age limit is reached, to confirm the correct forecast of deteriorating process, to confirm the effectiveness of the remedy to defects and to confirm the accuracy of predicting the behavior of facilities. The reliability of nuclear valves, fuel assemblies, the heat affected zones in welding, reactor cooling pumps and electric instruments has been tested or is being tested. (Kako, I.)

  7. The Reliability of Results from National Tests, Public Examinations, and Vocational Qualifications in England

    Science.gov (United States)

    He, Qingping; Opposs, Dennis

    2012-01-01

    National tests, public examinations, and vocational qualifications in England are used for a variety of purposes, including the certification of individual learners in different subject areas and the accountability of individual professionals and institutions. However, there has been ongoing debate about the reliability and validity of their…

  8. Factors that influence standard automated perimetry test results in glaucoma: test reliability, technician experience, time of day, and season.

    Science.gov (United States)

    Junoy Montolio, Francisco G; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M

    2012-10-09

    To determine the influence of several factors on standard automated perimetry test results in glaucoma. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience, time of day, and season on the mean deviation (MD) was determined by performing linear regression analysis of MD against time on a series of visual fields and subsequently performing a multiple linear regression analysis with the MD residuals as dependent variable and the factors mentioned above as independent variables. Analyses were performed with and without adjustment for the test reliability (fixation losses and false-positive and false-negative answers) and with and without stratification according to disease stage (baseline MD). Mean follow-up was 9.4 years, with on average 10.8 tests per patient. Technician experience, time of day, and season were associated with the MD. Approximately 0.2 dB lower MD values were found for inexperienced technicians (P Technician experience, time of day, season, and the percentage of false-positive answers have a significant influence on the MD of standard automated perimetry.

  9. The reliability of test results from simple test samples in predicting the fatigue performance of automotive components

    International Nuclear Information System (INIS)

    Fourlaris, G.; Ellwood, R.; Jones, T.B.

    2007-01-01

    The use of high strength steels (HSS) in automotive components is steadily increasing as automotive designers use modern steel grades to improve structural performance, reduce vehicle weight and enhance crash performance. Weight reduction can be achieved by substituting mild steel with a thinner gauge HSS, however, it must be ensured that no deterioration in performance including fatigue capability occurs. In this study, tests have been carried out to determine the effects that gauge and material strength have on the fatigue performance of a fusion welded automotive suspension arm. Current finite element (FE) modelling and fatigue prediction techniques have been evaluated to determine their reliability when used for thin strip steels. Results have shown the fatigue performance of welded components to be independent of the strength of the parent material for the steel grades studied, with material thickness and joining process the key features determining the fatigue performance. The correlation between the fatigue performance of simple welded samples under uniaxial, constant amplitude loading and complex components under biaxial in service road load data, has been shown to be unreliable. This study also indicates that with the application of modern technologies, such as tailor-welded blanks (TWB), significant weight savings can be achieved. This is demonstrated by a 19% weight reduction with no detrimental effect on the fatigue performance

  10. Demands placed on waste package performance testing and modeling by some general results on reliability analysis

    International Nuclear Information System (INIS)

    Chesnut, D.A.

    1991-09-01

    Waste packages for a US nuclear waste repository are required to provide reasonable assurance of maintaining substantially complete containment of radionuclides for 300 to 1000 years after closure. The waiting time to failure for complex failure processes affecting engineered or manufactured systems is often found to be an exponentially-distributed random variable. Assuming that this simple distribution can be used to describe the behavior of a hypothetical single barrier waste package, calculations presented in this paper show that the mean time to failure (the only parameter needed to completely specify an exponential distribution) would have to be more than 10 7 years in order to provide reasonable assurance of meeting this requirement. With two independent barriers, each would need to have a mean time to failure of only 10 5 years to provide the same reliability. Other examples illustrate how multiple barriers can provide a strategy for not only achieving but demonstrating regulatory compliance

  11. Preliminary study for the reliability Assurance on results and procedure of the out-pile mechanical characterization test for a fuel assembly; Lateral Vibration Test (I)

    International Nuclear Information System (INIS)

    Lee, Kang Hee; Yoon, Kyung Hee; Kim, Hyung Kyu

    2007-01-01

    The reliability assurance with respect to the test procedure and results of the out-pile mechanical performance test for the nuclear fuel assembly is an essential task to assure the test quality and to get a permission for fuel loading into the commercial reactor core. For the case of vibration test, proper management and appropriate calibration of instruments and devices used in the test, various efforts to minimize the possible error during the test and signal acquisition process are needed. Additionally, the deep understanding both of the theoretical assumption and simplification for the signal processing/modal analysis and of the functions of the devices used in the test were highly required. In this study, the overall procedure and result of lateral vibration test were assembly's mechanical characterization were briefly introduced. A series of measures to assure and improve the reliability of the vibration test were discussed

  12. Preliminary study for the reliability Assurance on results and procedure of the out-pile mechanical characterization test for a fuel assembly; Lateral Vibration Test (I)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Hee; Yoon, Kyung Hee; Kim, Hyung Kyu [KAERI, Daejeon (Korea, Republic of)

    2007-07-01

    The reliability assurance with respect to the test procedure and results of the out-pile mechanical performance test for the nuclear fuel assembly is an essential task to assure the test quality and to get a permission for fuel loading into the commercial reactor core. For the case of vibration test, proper management and appropriate calibration of instruments and devices used in the test, various efforts to minimize the possible error during the test and signal acquisition process are needed. Additionally, the deep understanding both of the theoretical assumption and simplification for the signal processing/modal analysis and of the functions of the devices used in the test were highly required. In this study, the overall procedure and result of lateral vibration test were assembly's mechanical characterization were briefly introduced. A series of measures to assure and improve the reliability of the vibration test were discussed.

  13. Factors That Influence Standard Automated Perimetry Test Results in Glaucoma : Test Reliability, Technician Experience, Time of Day, and Season

    NARCIS (Netherlands)

    Montolio, Francisco G. Junoy; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M.

    2012-01-01

    PURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience,

  14. Factors that influence standard automated perimetry test results in glaucoma: Test reliability, technician experience, time of day, and season

    NARCIS (Netherlands)

    F.G.J. Montolio (Francisco G. Junoy); C. Wesselink (Christiaan); M.C.M. Gordijn (Marijke); N.M. Jansonius (Nomdo)

    2012-01-01

    textabstractPURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician

  15. Reliability of D-Dimer test results in deciding the necessity of performing CTA in high risk population to establish the diagnosis of PE

    Directory of Open Access Journals (Sweden)

    Saher Ebrahim Taman

    2016-06-01

    Conclusion: Negative D-Dimer test is a reliable diagnostic modality to rule out the need for CT Angiography in patients at high risk population of PE. However, positive test results cannot confirm the diagnosis and further testing is warranted.

  16. [Reliability for detection of developmental problems using the semaphore from the Child Development Evaluation test: Is a yellow result different from a red result?

    Science.gov (United States)

    Rizzoli-Córdoba, Antonio; Ortega-Ríosvelasco, Fernando; Villasís-Keever, Miguel Ángel; Pizarro-Castellanos, Mariel; Buenrostro-Márquez, Guillermo; Aceves-Villagrán, Daniel; O'Shea-Cuevas, Gabriel; Muñoz-Hernández, Onofre

    The Child Development Evaluation (CDE) is a screening tool designed and validated in Mexico for detecting developmental problems. The result is expressed through a semaphore. In the CDE test, both yellow and red results are considered positive, although a different intervention is proposed for each. The aim of this work was to evaluate the reliability of the CDE test to discriminate between children with yellow/red result based on the developmental domain quotient (DDQ) obtained through the Battelle Development Inventory, 2nd edition (in Spanish) (BDI-2). The information was obtained for the study from the validation. Children with a normal (green) result in the CDE were excluded. Two different cut-off points of the DDQ were used (BDI-2): social: 20.1% vs. 28.9%; and adaptive: 6.9% vs. 20.4%. The semaphore result yellow/red allows identifying different magnitudes of delay in developmental domains or subdomains, supporting the recommendation of different interventions for each one. Copyright © 2014 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  17. Testing Standard Reliability Criteria

    Science.gov (United States)

    Sherry, David

    2017-01-01

    Maul's paper, "Rethinking Traditional Methods of Survey Validation" (Andrew Maul), contains two stages. First he presents empirical results that cast doubt on traditional methods for validating psychological measurement instruments. These results motivate the second stage, a critique of current conceptions of psychological measurement…

  18. Test Reliability at the Individual Level

    Science.gov (United States)

    Hu, Yueqin; Nesselroade, John R.; Erbacher, Monica K.; Boker, Steven M.; Burt, S. Alexandra; Keel, Pamela K.; Neale, Michael C.; Sisk, Cheryl L.; Klump, Kelly

    2016-01-01

    Reliability has a long history as one of the key psychometric properties of a test. However, a given test might not measure people equally reliably. Test scores from some individuals may have considerably greater error than others. This study proposed two approaches using intraindividual variation to estimate test reliability for each person. A simulation study suggested that the parallel tests approach and the structural equation modeling approach recovered the simulated reliability coefficients. Then in an empirical study, where forty-five females were measured daily on the Positive and Negative Affect Schedule (PANAS) for 45 consecutive days, separate estimates of reliability were generated for each person. Results showed that reliability estimates of the PANAS varied substantially from person to person. The methods provided in this article apply to tests measuring changeable attributes and require repeated measures across time on each individual. This article also provides a set of parallel forms of PANAS. PMID:28936107

  19. Prediction of safety critical software operational reliability from test reliability using testing environment factors

    International Nuclear Information System (INIS)

    Jung, Hoan Sung; Seong, Poong Hyun

    1999-01-01

    It has been a critical issue to predict the safety critical software reliability in nuclear engineering area. For many years, many researches have focused on the quantification of software reliability and there have been many models developed to quantify software reliability. Most software reliability models estimate the reliability with the failure data collected during the test assuming that the test environments well represent the operation profile. User's interest is however on the operational reliability rather than on the test reliability. The experiences show that the operational reliability is higher than the test reliability. With the assumption that the difference in reliability results from the change of environment, from testing to operation, testing environment factors comprising the aging factor and the coverage factor are developed in this paper and used to predict the ultimate operational reliability with the failure data in testing phase. It is by incorporating test environments applied beyond the operational profile into testing environment factors. The application results show that the proposed method can estimate the operational reliability accurately. (Author). 14 refs., 1 tab., 1 fig

  20. Test-retest reliability of cognitive EEG

    Science.gov (United States)

    McEvoy, L. K.; Smith, M. E.; Gevins, A.

    2000-01-01

    OBJECTIVE: Task-related EEG is sensitive to changes in cognitive state produced by increased task difficulty and by transient impairment. If task-related EEG has high test-retest reliability, it could be used as part of a clinical test to assess changes in cognitive function. The aim of this study was to determine the reliability of the EEG recorded during the performance of a working memory (WM) task and a psychomotor vigilance task (PVT). METHODS: EEG was recorded while subjects rested quietly and while they performed the tasks. Within session (test-retest interval of approximately 1 h) and between session (test-retest interval of approximately 7 days) reliability was calculated for four EEG components: frontal midline theta at Fz, posterior theta at Pz, and slow and fast alpha at Pz. RESULTS: Task-related EEG was highly reliable within and between sessions (r0.9 for all components in WM task, and r0.8 for all components in the PVT). Resting EEG also showed high reliability, although the magnitude of the correlation was somewhat smaller than that of the task-related EEG (r0.7 for all 4 components). CONCLUSIONS: These results suggest that under appropriate conditions, task-related EEG has sufficient retest reliability for use in assessing clinical changes in cognitive status.

  1. Prediction of software operational reliability using testing environment factors

    International Nuclear Information System (INIS)

    Jung, Hoan Sung; Seong, Poong Hyun

    1995-01-01

    For many years, many researches have focused on the quantification of software reliability and there are many models developed to quantify software reliability. Most software reliability models estimate the reliability with the failure data collected during the test assuming that the test environments well represent the operation profile. The experiences show that the operational reliability is higher than the test reliability User's interest is on the operational reliability rather than on the test reliability, however. With the assumption that the difference in reliability results from the change of environment, testing environment factors comprising the aging factor and the coverage factor are defined in this study to predict the ultimate operational reliability with the failure data. It is by incorporating test environments applied beyond the operational profile into testing environment factors. The application results are close to the actual data

  2. Reliability tests for reactor internals replacement technology

    International Nuclear Information System (INIS)

    Fujimaki, K.; Uchiyama, J.; Ohtsubo, T.

    2000-01-01

    Structural damage due to aging degradation of LWR reactor internals has been reported in several nuclear plants. NUPEC has started a project to test the reliability of the technology for replacing reactor internals, which was directed at preventive maintenance before damage and repair after damage for the aging degradation. The project has been funded by the Ministry of International Trade and Industry (MITI) of Japan since 1995, and it follows the policy of a report that the MITI has formally issued in April 1996 summarizing the countermeasures to be considered for aging nuclear plants and equipment. This paper gives an outline of the whole test plans and the test results for the BWR reactor internals replacement methods; core shroud, ICM housing, and CRD Housing and stub tube. The test results have shown that the methods were reliable and the structural integrity was appropriate based on the evaluation. (author)

  3. Reliability tests for reactor internals rejuvenation technology

    International Nuclear Information System (INIS)

    Fujimaki, Katsumi; Hitoki, Yoichi; Otsubo, Toru; Uchiyama, Junichi

    1998-01-01

    Structural damage due to aging degradation of LWR reactor internals has been reported in several nuclear plants. NUPEC has started a project to test the reliability of the technology for rejuvenating reactor internals which has been funded by the Ministry of International Trade and Industry (MITI) of Japan since 1995. The project follows the policy of a report that the MITI has formally issued in April 1996 summarizing the countermeasures to be considered for aging nuclear plants and equipment. This paper gives an outline of the test plans and results which are directed at preventive maintenance before damage and repair after damage for reactor internals aging degradation. The test results for the replacement methods of ICM housing and BWR core shroud have shown that the methods were reliable and the structural integrity was appropriate based on the evaluation. (author)

  4. How stable are quantitative sensory testing measurements over time? Report on 10-week reliability and agreement of results in healthy volunteers

    Directory of Open Access Journals (Sweden)

    Nothnagel H

    2017-08-01

    Full Text Available Helen Nothnagel,1,2,* Christian Puta,1,3,* Thomas Lehmann,4 Philipp Baumbach,5 Martha B Menard,6,7 Brunhild Gabriel,1 Holger H W Gabriel,1 Thomas Weiss,8 Frauke Musial2 1Department of Sports Medicine and Health Promotion, Friedrich Schiller University, Jena, Germany; 2Department of Community Medicine, National Research Center in Complementary and Alternative Medicine, UiT, The Arctic University of Norway, Tromsø, Norway; 3Center for Interdisciplinary Prevention of Diseases Related to Professional Activities, 4Department of Medical Statistics, Computer Sciences and Documentation, Friedrich Schiller University, 5Department of Anesthesiology and Intensive Care Medicine, University Hospital Jena, Germany; 6Crocker Institute, Kiawah Island, SC, 7School of Integrative Medicine and Health Sciences, Saybrook University, Oakland, CA, USA; 8Department of Biological and Clinical Psychology, Friedrich Schiller University, Jena, Germany *These authors contributed equally to this work Background: Quantitative sensory testing (QST is a diagnostic tool for the assessment of the somatosensory system. To establish QST as an outcome measure for clinical trials, the question of how similar the measurements are over time is crucial. Therefore, long-term reliability and limits of agreement of the standardized QST protocol of the German Research Network on Neuropathic Pain were tested. Methods: QST on the lower back and hand dorsum (dominant hand were assessed twice in 22 healthy volunteers (10 males and 12 females; mean age: 46.6±13.0 years, with sessions separated by 10.0±2.9 weeks. All measurements were performed by one investigator. To investigate long-term reliability and agreement of QST, differences between the two measurements, correlation coefficients, intraclass correlation coefficients (ICCs, Bland–Altman plots (limits of agreement, and standard error of measurement were used. Results: Most parameters of the QST were reliable over 10 weeks in

  5. Developing MESA : an accelerated reliability test

    NARCIS (Netherlands)

    Baskoro, G.; Rouvroye, J.L.; Bacher, W.; Brombacher, A.C.

    2003-01-01

    This paper describes the on-going research on an accelerated reliability test strategy called MESA (Multiple Environment Stress Analysis) intended to find in a fast and efficient manner (potential) reliability problems during the design phase of high volume consumer products. This test has shown

  6. Research on the Reliability Testing of Electrical Automation Control Equipment

    OpenAIRE

    Yongjie Luo

    2014-01-01

    According to the author’s many years’ work experience, this paper first discusses the concepts of electrical automation control equipment reliability testing, and then analyzes the test method of electrical automation control equipment reliability testing, finally, on this basis, this article discusses how to determine the reliability test method of electrical automation control equipment. Results of this study will provide a useful reference for electrical automation control equipment reliab...

  7. Prediction of software operational reliability using testing environment factor

    International Nuclear Information System (INIS)

    Jung, Hoan Sung

    1995-02-01

    Software reliability is especially important to customers these days. The need to quantify software reliability of safety-critical systems has been received very special attention and the reliability is rated as one of software's most important attributes. Since the software is an intellectual product of human activity and since it is logically complex, the failures are inevitable. No standard models have been established to prove the correctness and to estimate the reliability of software systems by analysis and/or testing. For many years, many researches have focused on the quantification of software reliability and there are many models developed to quantify software reliability. Most software reliability models estimate the reliability with the failure data collected during the test assuming that the test environments well represent the operation profile. User's interest is on the operational reliability rather than on the test reliability, however. The experiences show that the operational reliability is higher than the test reliability. With the assumption that the difference in reliability results from the change of environment, testing environment factor comprising the aging factor and the coverage factor are defined in this work to predict the ultimate operational reliability with the failure data. It is by incorporating test environments applied beyond the operational profile into testing environment factor Test reliability can also be estimated with this approach without any model change. The application results are close to the actual data. The approach used in this thesis is expected to be applicable to ultra high reliable software systems that are used in nuclear power plants, airplanes, and other safety-critical applications

  8. Reliability Generalization of the Alcohol Use Disorder Identification Test.

    Science.gov (United States)

    Shields, Alan L.; Caruso, John C.

    2002-01-01

    Evaluated the reliability of scores from the Alcohol Use Disorders Identification Test (AUDIT; J. Sounders and others, 1993) in a reliability generalization study based on 17 empirical journal articles. Results show AUDIT scores to be generally reliable for basic assessment. (SLD)

  9. Human Reliability Data Bank: evaluation results

    International Nuclear Information System (INIS)

    Comer, M.K.; Donovan, M.D.; Gaddy, C.D.

    1985-01-01

    The US Nuclear Regulatory Commission (NRC), Sandia National Laboratories (SNL), and General Physics Corporation are conducting a research program to determine the practicality, acceptability, and usefulness of a Human Reliability Data Bank for nuclear power industry probabilistic risk assessment (PRA). As part of this program, a survey was conducted of existing human reliability data banks from other industries, and a detailed concept of a Data Bank for the nuclear industry was developed. Subsequently, a detailed specification for implementing the Data Bank was developed. An evaluation of this specification was conducted and is described in this report. The evaluation tested data treatment, storage, and retrieval using the Data Bank structure, as modified from NUREG/CR-2744, and detailed procedures for data processing and retrieval, developed prior to this evaluation and documented in the test specification. The evaluation consisted of an Operability Demonstration and Evaluation of the data processing procedures, a Data Retrieval Demonstration and Evaluation, a Retrospective Analysis that included a survey of organizations currently operating data banks for the nuclear power industry, and an Internal Analysis of the current Data Bank System

  10. Reliability of non-destructive testing methods

    International Nuclear Information System (INIS)

    Broekhoven, M.J.G.

    1988-01-01

    This contribution regards the results of an evaluation of the reliability of radiography (X-rays and gamma-rays), manual-, and mechanized/automated ultrasonic examination by generally accepted codes/rules, with respect to detection, characterization and sizing/localization of defects. The evaluation is based on the results of examinations, by a number of teams, of 30 test plates, 30 and 50 mm thickness, containing V,U, X and K-shaped welds each containing several types of imperfections (211) in total) typical for steel arc fusion welding, such as porosity, inclusions, lack of fusion or penetration and cracks. Besides, some results are presented obtained from research on advanced UT-techniques, viz. the time-of-flight-diffraction and flaw-tip deflection technique. (author)

  11. Reliability of non-destructive testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Broekhoven, M J.G. [Ministry of Social Affairs, (Netherlands)

    1988-12-31

    This contribution regards the results of an evaluation of the reliability of radiography (X-rays and gamma-rays), manual-, and mechanized/automated ultrasonic examination by generally accepted codes/rules, with respect to detection, characterization and sizing/localization of defects. The evaluation is based on the results of examinations, by a number of teams, of 30 test plates, 30 and 50 mm thickness, containing V,U, X and K-shaped welds each containing several types of imperfections (211) in total) typical for steel arc fusion welding, such as porosity, inclusions, lack of fusion or penetration and cracks. Besides, some results are presented obtained from research on advanced UT-techniques, viz. the time-of-flight-diffraction and flaw-tip deflection technique. (author). 4 refs.

  12. SLAC modulator system improvements and reliability results

    International Nuclear Information System (INIS)

    Donaldson, A.R.

    1998-06-01

    In 1995, an improvement project was completed on the 244 klystron modulators in the linear accelerator. The modulator system has been previously described. This article offers project details and their resulting effect on modulator and component reliability. Prior to the project, the authors had collected four operating cycles (1991 through 1995) of MTTF data. In this discussion, the '91 data will be excluded since the modulators operated at 60 Hz. The five periods following the '91 run were reviewed due to the common repetition rate at 120 Hz

  13. Reliability test for reactor internals rejuvenation technology

    International Nuclear Information System (INIS)

    Uchiyama, Junichi

    1998-01-01

    41 transparencies were presented on the subject of 'Reliability test for reactor internals rejuvenation technology'. The items presented give an introduction on the management of plant life in Japan and introduce the Nuclear Power Engineering Corporation (NUPEC). The question of what reliability tests for rejuvenation of reactor internals are is discussed in some detail and an outline of each test is given. Altogether six methods to rejuvenate reactor internals are presented, two of which have already been applied to actual plants. The presentation was supported by many detailed drawings and images

  14. Reliability testing of failed fuel location system

    International Nuclear Information System (INIS)

    Vieru, G.

    1996-01-01

    This paper presents the experimental reliability tests performed in order to prove the reliability parameters for Failed Fuel Location System (FFLS), equipment used to detect in which channel of a particular heat transport loop a fuel failure is located, and to find in which channel what particular bundle pair is failed. To do so, D20 samples from each reactor channel are sequentially monitored to detect a comparatively high level of delayed neutron activity. 15 refs, 8 figs, 2 tabs

  15. Reliability demonstration test planning using bayesian analysis

    International Nuclear Information System (INIS)

    Chandran, Senthil Kumar; Arul, John A.

    2003-01-01

    In Nuclear Power Plants, the reliability of all the safety systems is very critical from the safety viewpoint and it is very essential that the required reliability requirements be met while satisfying the design constraints. From practical experience, it is found that the reliability of complex systems such as Safety Rod Drive Mechanism is of the order of 10 -4 with an uncertainty factor of 10. To demonstrate the reliability of such systems is prohibitive in terms of cost and time as the number of tests needed is very large. The purpose of this paper is to develop a Bayesian reliability demonstrating testing procedure for exponentially distributed failure times with gamma prior distribution on the failure rate which can be easily and effectively used to demonstrate component/subsystem/system reliability conformance to stated requirements. The important questions addressed in this paper are: With zero failures, how long one should perform the tests and how many components are required to conclude with a given degree of confidence, that the component under test, meets the reliability requirement. The procedure is explained with an example. This procedure can also be extended to demonstrate with more number of failures. The approach presented is applicable for deriving test plans for demonstrating component failure rates of nuclear power plants, as the failure data for similar components are becoming available in existing plants elsewhere. The advantages of this procedure are the criterion upon which the procedure is based is simple and pertinent, the fitting of the prior distribution is an integral part of the procedure and is based on the use of information regarding two percentiles of this distribution and finally, the procedure is straightforward and easy to apply in practice. (author)

  16. Reliability Testing of Cable on Environmental Humidity Condition

    International Nuclear Information System (INIS)

    Situmorang, Johnny; Puradwi, I.W; Sony T, D.T; Handoyo, Demon; Mulyanto, Dwijo; Kusmono, Slamet

    2000-01-01

    Reliability testing of cable on humidified condition has been carried out. As a result, the failure occurred due to reduction of current by increasing the resistance on rising temperature testing. For humidified condition the result which are observed did not significant at the stated condition of testing. The needed time up to the failure criteria increased as a temperature testing increased

  17. Enhance pump reliability through improved inservice testing

    International Nuclear Information System (INIS)

    Healy, J.J.

    1990-01-01

    EPRI has undertaken a study to assess the effectiveness of existing testing programs to accurately monitor and predict performance changes before either pump performance degrades or an actual failure occurs. Anticipated changes in inservice testing techniques are directed towards enhancing the validity of test data, ensuring its repeatability, and avoiding deterioration of the pump assembly. There is a new-found interest in test programs of all types that has occurred, in part, because of an increase in reported pump degradation and pump failure. Inservice testing of pumps, which has long been a basis for assuring operability, has apparently produced an opposite effect; namely, the appearance of a reduction in reliability

  18. Reliability analysis applied to structural tests

    Science.gov (United States)

    Diamond, P.; Payne, A. O.

    1972-01-01

    The application of reliability theory to predict, from structural fatigue test data, the risk of failure of a structure under service conditions because its load-carrying capability is progressively reduced by the extension of a fatigue crack, is considered. The procedure is applicable to both safe-life and fail-safe structures and, for a prescribed safety level, it will enable an inspection procedure to be planned or, if inspection is not feasible, it will evaluate the life to replacement. The theory has been further developed to cope with the case of structures with initial cracks, such as can occur in modern high-strength materials which are susceptible to the formation of small flaws during the production process. The method has been applied to a structure of high-strength steel and the results are compared with those obtained by the current life estimation procedures. This has shown that the conventional methods can be unconservative in certain cases, depending on the characteristics of the structure and the design operating conditions. The suitability of the probabilistic approach to the interpretation of the results from full-scale fatigue testing of aircraft structures is discussed and the assumptions involved are examined.

  19. Reliability Testing Using the Vehicle Durability Simulator

    Science.gov (United States)

    2017-11-20

    techniques are employed to reduce test and simulation time. Through application of these processes and techniques the reliability characteristics...remote parameter control (RPC) software. The software is specifically designed for the data collection, analysis, and simulation processes outlined in...the selection process for determining the desired runs for simulation . 4.3 Drive File Development. After the data have been reviewed and

  20. A test chip for automatic reliability measurements of interconnect vias

    NARCIS (Netherlands)

    Lippe, K.; Hasper, A.; Elfrink, G.W.; Niehof, J.; Kerkhoff, Hans G.

    1992-01-01

    A test circuit for electromigration reliability measurements was designed and tested. The device under test (DUT) is a via-hole chain. The test circuit permits simultaneous measurements of a number of DUTs, and a fatal error of one DUT does not influence the measurement results of the other DUTs.

  1. Prediction of software operational reliability using testing environment factors

    International Nuclear Information System (INIS)

    Jung, Hoan Sung; Seong, Poong Hyun

    1995-01-01

    A number of software reliability models have been developed to estimate and to predict software reliability. However, there are no established standard models to quantify software reliability. Most models estimate the quality of software in reliability figures such as remaining faults, failure rate, or mean time to next failure at the testing phase, and they consider them ultimate indicators of software reliability. Experience shows that there is a large gap between predicted reliability during development and reliability measured during operation, which means that predicted reliability, or so-called test reliability, is not operational reliability. Customers prefer operational reliability to test reliability. In this study, we propose a method that predicts operational reliability rather than test reliability by introducing the testing environment factor that quantifies the changes in environments

  2. Reliability performance of standby equipment with periodic testing

    International Nuclear Information System (INIS)

    Sim, S.H.

    1985-11-01

    In this report, the reliability performance of standby equipment subjected to periodic testing is studied. analytical expressions have been derived for reliability measures, such as the man accumulated operating time to failure, the expected number of tests between two consecutive failures, the mean time to failure following an emergency start-up and the probability of failing to complete an emergency mission of a specified duration. These results are useful for the reliability assessment of standby equipment such as combustion turbine units of the emergency power supply system, and of the Class III power system at a nuclear generating station

  3. Proving Test on the Reliability for Reactor Containment Vessel

    International Nuclear Information System (INIS)

    Takumi, K.; Nonaka, A.

    1988-01-01

    NUPEC (Nuclear Power Engineering Test Center) has started an eight-year project of Proving Test on the Reliability for Reactor Containment Vessel since June 1987. The objective of this project is to confirm the integrity of containment vessels under severe accident conditions. This paper shows the outline of this project. The test Items are (1) Hydrogen mixing and distribution test, (2) Hydrogen burning test, (3) Iodine trapping characteristics test, and (4) Structural behavior test. Based on the test results, computer codes are verified and as the results of analysis and evaluation by the computer codes, containment integrity is to be confirmed

  4. Reliability of provocative tests of motion sickness susceptibility

    Science.gov (United States)

    Calkins, D. S.; Reschke, M. F.; Kennedy, R. S.; Dunlop, W. P.

    1987-01-01

    Test-retest reliability values were derived from motion sickness susceptibility scores obtained from two successive exposures to each of three tests: (1) Coriolis sickness sensitivity test; (2) staircase velocity movement test; and (3) parabolic flight static chair test. The reliability of the three tests ranged from 0.70 to 0.88. Normalizing values from predictors with skewed distributions improved the reliability.

  5. Reliability of four experimental mechanical pain tests in children

    Directory of Open Access Journals (Sweden)

    Soee AL

    2013-02-01

    Full Text Available Ann-Britt L Soee,1 Lise L Thomsen,2 Birte Tornoe,1,3 Liselotte Skov11Department of Pediatrics, Children’s Headache Clinic, Copenhagen University Hospital Herlev, Copenhagen, Denmark; 2Department of Neuropediatrics, Juliane Marie Centre, Copenhagen University Hospital Rigshospitalet, København Ø, Denmark; 3Department of Physiotherapy, Medical Department O, Copenhagen University Hospital Herlev, Herlev, DenmarkPurpose: In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT in healthy children. Furthermore, the aim was also to study the intersession reliability of the following four tests: (1 Total Tenderness Score; (2 PPT; (3 Visual Analog Scale score at suprapressure pain threshold; and (4 area under the curve (stimulus–response functions for pressure versus pain.Participants and methods: Twenty-five healthy school children, 8–14 years of age, participated. Test 2, PPT, was repeated three times at 2 minute intervals on the same day to estimate PPT intrasession reliability using Cronbach’s alpha. Tests 1–4 were repeated after median 21 (interquartile range 10.5–22 days, and Pearson’s correlation coefficient was used to describe the intersession reliability.Results: The PPT test was precise and reliable (Cronbach’s alpha ≥ 0.92. All tests showed a good to excellent correlation between days (intersessions r = 0.66–0.81. There were no indications of significant systematic differences found in any of the four tests between days.Conclusion: All tests seemed to be reliable measurements in pain evaluation in healthy children aged 8–14 years. Given the small sample size, this conclusion needs to be confirmed in future studies.Keywords: repeatability, intraindividual reliability, pressure pain threshold, pain measurement, algometer

  6. Reliability of movement control tests in the lumbar spine

    Directory of Open Access Journals (Sweden)

    de Bruin Eling D

    2007-09-01

    Full Text Available Abstract Background Movement control dysfunction [MCD] reduces active control of movements. Patients with MCD might form an important subgroup among patients with non specific low back pain. The diagnosis is based on the observation of active movements. Although widely used clinically, only a few studies have been performed to determine the test reliability. The aim of this study was to determine the inter- and intra-observer reliability of movement control dysfunction tests of the lumbar spine. Methods We videoed patients performing a standardized test battery consisting of 10 active movement tests for motor control in 27 patients with non specific low back pain and 13 patients with other diagnoses but without back pain. Four physiotherapists independently rated test performances as correct or incorrect per observation, blinded to all other patient information and to each other. The study was conducted in a private physiotherapy outpatient practice in Reinach, Switzerland. Kappa coefficients, percentage agreements and confidence intervals for inter- and intra-rater results were calculated. Results The kappa values for inter-tester reliability ranged between 0.24 – 0.71. Six tests out of ten showed a substantial reliability [k > 0.6]. Intra-tester reliability was between 0.51 – 0.96, all tests but one showed substantial reliability [k > 0.6]. Conclusion Physiotherapists were able to reliably rate most of the tests in this series of motor control tasks as being performed correctly or not, by viewing films of patients with and without back pain performing the task.

  7. Models on reliability of non-destructive testing

    International Nuclear Information System (INIS)

    Simola, K.; Pulkkinen, U.

    1998-01-01

    The reliability of ultrasonic inspections has been studied in e.g. international PISC (Programme for the Inspection of Steel Components) exercises. These exercises have produced a large amount of information on the effect of various factors on the reliability of inspections. The information obtained from reliability experiments are used to model the dependency of flaw detection probability on various factors and to evaluate the performance of inspection equipment, including the sizing accuracy. The information from experiments is utilised in a most effective way when mathematical models are applied. Here, some statistical models for reliability of non-destructive tests are introduced. In order to demonstrate the use of inspection reliability models, they have been applied to the inspection results of intergranular stress corrosion cracking (IGSCC) type flaws in PISC III exercise (PISC 1995). The models are applied to both flaw detection frequency data of all inspection teams and to flaw sizing data of one participating team. (author)

  8. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  9. Climax granite test results

    Energy Technology Data Exchange (ETDEWEB)

    Ramspott, L.D.

    1980-01-15

    The Lawrence Livermore Laboratory (LLL), as part of the Nevada Nuclear Waste Storage Investigations (NNWSI) program, is carrying out in situ rock mechanics testing in the Climax granitic stock at the Nevada Test Site (NTS). This summary addresses only those field data taken to date that address thermomechanical modeling for a hard-rock repository. The results to be discussed include thermal measurements in a heater test that was conducted from October 1977 through July 1978, and stress and displacement measurements made during and after excavation of the canister storage drift for the Spent Fuel Test (SFT) in the Climax granite. Associated laboratory and field measurements are summarized. The rock temperature for a given applied heat load at a point in time and space can be adequately modeled with simple analytic calculations involving superposition and integration of numerous point source solutions. The input, for locations beyond about a meter from the source, can be a constant thermal conductivity and diffusivity. The value of thermal conductivity required to match the field data is as much as 25% different from laboratory-measured values. Therefore, unless we come to understand the mechanisms for this difference, a simple in situ test will be required to obtain a value for final repository design. Some sensitivity calculations have shown that the temperature field is about ten times more sensitive to conductivity than to diffusivity under the test conditions. The orthogonal array was designed to detect anisotropy. After considering all error sources, anisotropic efforts in the thermal field were less than 5 to 10%.

  10. A study of operational and testing reliability in software reliability analysis

    International Nuclear Information System (INIS)

    Yang, B.; Xie, M.

    2000-01-01

    Software reliability is an important aspect of any complex equipment today. Software reliability is usually estimated based on reliability models such as nonhomogeneous Poisson process (NHPP) models. Software systems are improving in testing phase, while it normally does not change in operational phase. Depending on whether the reliability is to be predicted for testing phase or operation phase, different measure should be used. In this paper, two different reliability concepts, namely, the operational reliability and the testing reliability, are clarified and studied in detail. These concepts have been mixed up or even misused in some existing literature. Using different reliability concept will lead to different reliability values obtained and it will further lead to different reliability-based decisions made. The difference of the estimated reliabilities is studied and the effect on the optimal release time is investigated

  11. Test-Retest Reliability and Predictive Validity of the Implicit Association Test in Children

    Science.gov (United States)

    Rae, James R.; Olson, Kristina R.

    2018-01-01

    The Implicit Association Test (IAT) is increasingly used in developmental research despite minimal evidence of whether children's IAT scores are reliable across time or predictive of behavior. When test-retest reliability and predictive validity have been assessed, the results have been mixed, and because these studies have differed on many…

  12. The reliability of finite element analysis results of the low impact test in predicting the energy absorption performance of thin-walled structures

    Energy Technology Data Exchange (ETDEWEB)

    Alipour, R.; Nejadx, Farokhi A.; Izman, S. [Universiti Teknologi Malaysia, Johor Bahru (Malaysia)

    2015-05-15

    The application of dual phase steels (DPS) such as DP600 in the form of thin-walled structure in automotive components is being continuously increased as vehicle designers utilize modern steel grades and low weight structures to improve structural performance, make automotive light and reinforce crash performance. Preventing cost enhancement of broad investigations in this area can be gained by using computers in structural analysis in order to substitute lots of experiments with finite element analysis (FEA). Nevertheless, it necessitates to be certified that selected method including element type and solution methodology is capable of predicting real condition. In this paper, numerical and experimental studies are done to specify the effect of element type selection and solution methodology on the results of finite element analysis in order to investigate the energy absorption behavior of a DP600 thin-walled structure with three different geometries under a low impact loading. The outcomes indicated the combination of implicit method and solid elements is in better agreement with the experiments. In addition, using a combination of shell element types with implicit method reduces the time of simulation remarkably, although the error of results compared to the experiments increased to some extent.

  13. FFTF [Fast Flux Test Facility] reactor shutdown system reliability reevaluation

    International Nuclear Information System (INIS)

    Pierce, B.F.

    1986-07-01

    The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations

  14. Influences on and Limitations of Classical Test Theory Reliability Estimates.

    Science.gov (United States)

    Arnold, Margery E.

    It is incorrect to say "the test is reliable" because reliability is a function not only of the test itself, but of many factors. The present paper explains how different factors affect classical reliability estimates such as test-retest, interrater, internal consistency, and equivalent forms coefficients. Furthermore, the limits of classical test…

  15. Exploration of reliability databases and comparison of former IFMIF's results

    International Nuclear Information System (INIS)

    Tapia, Carlos; Dies, Javier; Abal, Javier; Ibarra, Angel; Arroyo, Jose M.

    2011-01-01

    There is an uncertainty issue about the applicability of industrial databases to new designs, such as the International Fusion Materials Irradiation Facility (IFMIF), as they usually contain elements for which no historical statistics exist. The exploration of common components reliability data in Accelerator Driven Systems (ADS) and Liquid Metal Technologies (LMT) frameworks is the milestone to analyze the data used in IFMIF reliability's reports and for future studies. The comparison between the reliability accelerator results given in the former IFMIF's reports and the databases explored has been made by means of a new accelerator Reliability, Availability, Maintainability (RAM) analysis. The reliability database used in this analysis is traceable.

  16. Development of seismic technology and reliability based on vibration tests

    International Nuclear Information System (INIS)

    Sasaki, Youichi

    1997-01-01

    This paper deals with some of the vibration tests and investigations on the seismic safety of nuclear power plants (NPPs) in Japan. To ensure the reliability of the seismic safety of nuclear power plants, nuclear power plants in Japan have been designed according to the Technical Guidelines for Aseismic Design of Nuclear Power Plants. This guideline has been developed based on technical date base and findings which were obtained from many vibration tests and investigations. Besides the tests for the guideline, proving tests on seismic reliability of operating nuclear power plants equipment and systems have been carried out. In this paper some vibration tests and their evaluation results are presented. They have crucially contributed to develop the guideline. (J.P.N.)

  17. Development of seismic technology and reliability based on vibration tests

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Youichi [Nuclear Power Engineering Corp., Tokyo (Japan)

    1997-03-01

    This paper deals with some of the vibration tests and investigations on the seismic safety of nuclear power plants (NPPs) in Japan. To ensure the reliability of the seismic safety of nuclear power plants, nuclear power plants in Japan have been designed according to the Technical Guidelines for Aseismic Design of Nuclear Power Plants. This guideline has been developed based on technical date base and findings which were obtained from many vibration tests and investigations. Besides the tests for the guideline, proving tests on seismic reliability of operating nuclear power plants equipment and systems have been carried out. In this paper some vibration tests and their evaluation results are presented. They have crucially contributed to develop the guideline. (J.P.N.)

  18. Reliability Evaluation of Concentric Butterfly Valve Using Statistical Hypothesis Test

    International Nuclear Information System (INIS)

    Chang, Mu Seong; Choi, Jong Sik; Choi, Byung Oh; Kim, Do Sik

    2015-01-01

    A butterfly valve is a type of flow-control device typically used to regulate a fluid flow. This paper presents an estimation of the shape parameter of the Weibull distribution, characteristic life, and B10 life for a concentric butterfly valve based on a statistical analysis of the reliability test data taken before and after the valve improvement. The difference in the shape and scale parameters between the existing and improved valves is reviewed using a statistical hypothesis test. The test results indicate that the shape parameter of the improved valve is similar to that of the existing valve, and that the scale parameter of the improved valve is found to have increased. These analysis results are particularly useful for a reliability qualification test and the determination of the service life cycles

  19. Reliability Evaluation of Concentric Butterfly Valve Using Statistical Hypothesis Test

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Mu Seong; Choi, Jong Sik; Choi, Byung Oh; Kim, Do Sik [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of)

    2015-12-15

    A butterfly valve is a type of flow-control device typically used to regulate a fluid flow. This paper presents an estimation of the shape parameter of the Weibull distribution, characteristic life, and B10 life for a concentric butterfly valve based on a statistical analysis of the reliability test data taken before and after the valve improvement. The difference in the shape and scale parameters between the existing and improved valves is reviewed using a statistical hypothesis test. The test results indicate that the shape parameter of the improved valve is similar to that of the existing valve, and that the scale parameter of the improved valve is found to have increased. These analysis results are particularly useful for a reliability qualification test and the determination of the service life cycles.

  20. Assessment of the quality of test results from selected civil engineering material testing laboratories in Tanzania

    CSIR Research Space (South Africa)

    Mbawala, SJ

    2017-12-01

    Full Text Available Civil and geotechnical engineering material testing laboratories are expected to produce accurate and reliable test results. However, the ability of laboratories to produce accurate and reliable test results depends on many factors, among others...

  1. Validity and Reliability of Baseline Testing in a Standardized Environment.

    Science.gov (United States)

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Link, H.; Keller, J.; Guo, Y.; McNiff, B.

    2013-04-01

    Gearboxes in wind turbines have not been achieving their expected design life even though they commonly meet or exceed the design criteria specified in current design standards. One of the basic premises of the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) is that the low gearbox reliability results from the absence of critical elements in the design process or insufficient design tools. Key goals of the GRC are to improve design approaches and analysis tools and to recommend practices and test methods resulting in improved design standards for wind turbine gearboxes that lower the cost of energy (COE) through improved reliability. The GRC uses a combined gearbox testing, modeling and analysis approach, along with a database of information from gearbox failures collected from overhauls and investigation of gearbox condition monitoring techniques to improve wind turbine operations and maintenance practices. Testing of Gearbox 2 (GB2) using the two-speed turbine controller that has been used in prior testing. This test series will investigate non-torque loads, high-speed shaft misalignment, and reproduction of field conditions in the dynamometer. This test series will also include vibration testing using an eddy-current brake on the gearbox's high speed shaft.

  3. Validity and reliability of the NAB Naming Test.

    Science.gov (United States)

    Sachs, Bonnie C; Rush, Beth K; Pedraza, Otto

    2016-05-01

    Confrontation naming is commonly assessed in neuropsychological practice, but few standardized measures of naming exist and those that do are susceptible to the effects of education and culture. The Neuropsychological Assessment Battery (NAB) Naming Test is a 31-item measure used to assess confrontation naming. Despite adequate psychometric information provided by the test publisher, there has been limited independent validation of the test. In this study, we investigated the convergent and discriminant validity, internal consistency, and alternate forms reliability of the NAB Naming Test in a sample of adults (Form 1: n = 247, Form 2: n = 151) clinically referred for neuropsychological evaluation. Results indicate adequate-to-good internal consistency and alternate forms reliability. We also found strong convergent validity as demonstrated by relationships with other neurocognitive measures. We found preliminary evidence that the NAB Naming Test demonstrates a more pronounced ceiling effect than other commonly used measures of naming. To our knowledge, this represents the largest published independent validation study of the NAB Naming Test in a clinical sample. Our findings suggest that the NAB Naming Test demonstrates adequate validity and reliability and merits consideration in the test arsenal of clinical neuropsychologists.

  4. Test-re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females.

    Science.gov (United States)

    Beardsley, Chris; Egerton, Tim; Skinner, Brendon

    2016-01-01

    Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.

  5. ACSC Indicator: testing reliability for hypertension.

    Science.gov (United States)

    Walker, Robin L; Ghali, William A; Chen, Guanmin; Khalsa, Tej K; Mangat, Birinder K; Campbell, Norm R C; Dixon, Elijah; Rabi, Doreen; Jette, Nathalie; Dhanoa, Robyn; Quan, Hude

    2017-06-26

    With high-quality community-based primary care, hospitalizations for ambulatory care sensitive conditions (ACSC) are considered avoidable. The purpose of this study was to test the inter-physician reliability of judgments of avoidable hospitalizations for one ACSC, uncomplicated hypertension, derived from medical chart review. We applied the Canadian Institute for Health Information's case definition to obtain a random sample of patients who had an ACSC hospitalization for uncomplicated hypertension in Calgary, Alberta. Medical chart review was conducted by three experienced internal medicine specialists. Implicit methods were used to judge avoidability of hospitalization using a validated 5-point scale. There was poor agreement among three physicians raters when judging the avoidability of 82 ACSC hospitalizations for uncomplicated hypertension (κ = 0.092). The κ also remained low when assessing agreement between raters 1 and 3 (κ = 0.092), but the κ was lower (less than chance agreement) for raters 1 and 2 (κ = -0.119) and raters 2 and 3 (κ = -0.008). When the 5-point scale was dichotomized, there was fair agreement among three raters (κ = 0.217). The proportion of ACSC hospitalizations for uncomplicated hypertension that were rated as avoidable was 32.9%, 6.1% and 26.8% for raters 1, 2, and 3, respectively. This study found a low proportion of ACSC hospitalization were rated as avoidable, with poor to fair agreement of judgment between physician raters. This suggests that the validity and utility of this health indicator is questionable. It points to a need to abandon the use of ACSC entirely; or alternatively to work on the development of explicit criteria for judging avoidability of hospitalization for ACSC such as hypertension.

  6. Reliability and validity of two isometric squat tests.

    Science.gov (United States)

    Blazevich, Anthony J; Gill, Nicholas; Newton, Robert U

    2002-05-01

    The purpose of the present study was first to examine the reliability of isometric squat (IS) and isometric forward hack squat (IFHS) tests to determine if repeated measures on the same subjects yielded reliable results. The second purpose was to examine the relation between isometric and dynamic measures of strength to assess validity. Fourteen male subjects performed maximal IS and IFHS tests on 2 occasions and 1 repetition maximum (1-RM) free-weight squat and forward hack squat (FHS) tests on 1 occasion. The 2 tests were found to be highly reliable (intraclass correlation coefficient [ICC](IS) = 0.97 and ICC(IFHS) = 1.00). There was a strong relation between average IS and 1-RM squat performance, and between IFHS and 1-RM FHS performance (r(squat) = 0.77, r(FHS) = 0.76; p squat and FHS test performances (r squat and FHS test performance can be attributed to differences in the movement patterns of the tests

  7. A COMPUTERIZED DIAGNOSTIC COMPLEX FOR RELIABILITY TESTING OF ELECTRIC MACHINES

    Directory of Open Access Journals (Sweden)

    O.О. Somka

    2015-06-01

    Full Text Available Purpose. To develop a diagnostic complex meeting the criteria and requirements for carrying out accelerated reliability test and realizing the basic modes of electric machines operation and performance of the posed problems necessary in the process of such test. Methodology. To determine and forecast the indices of electric machines reliability in accordance with the statistic data of repair plants we have conditionally divided them into structural parts that are most likely to fail. We have preliminarily assessed the state of each of these parts, which includes revelation of faults and deviations of technical and geometric parameters. We have determined the analyzed electric machine controlled parameters used for assessment of quantitative characteristics of reliability of these parts and electric machines on the whole. Results. As a result of the research, we have substantiated the structure of a computerized complex for electric machines reliability test. It allows us to change thermal and vibration actions without violation of the physics of the processes of aging and wearing of the basic structural parts and elements material. The above mentioned makes it possible to considerably reduce time spent on carrying out electric machines reliability tests and improve trustworthiness of the data obtained as a result of their performance. Originality. A special feature of determination of the controlled parameters consists in removal of vibration components in the idle mode and after disconnection of the analyzed electric machine from the power supply with the aim of singling out the vibration electromagnetic component, fixing the degree of sparking and bend of the shaft by means of phototechnique and local determination of structural parts temperature provided by corresponding location of thermal sensors. Practical value. We have offered a scheme of location of thermal and vibration sensors, which allows improvement of parameters measuring accuracy

  8. A standard for test reliability in group research.

    Science.gov (United States)

    Ellis, Jules L

    2013-03-01

    Many authors adhere to the rule that test reliabilities should be at least .70 or .80 in group research. This article introduces a new standard according to which reliabilities can be evaluated. This standard is based on the costs or time of the experiment and of administering the test. For example, if test administration costs are 7 % of the total experimental costs, the efficient value of the reliability is .93. If the actual reliability of a test is equal to this efficient reliability, the test size maximizes the statistical power of the experiment, given the costs. As a standard in experimental research, it is proposed that the reliability of the dependent variable be close to the efficient reliability. Adhering to this standard will enhance the statistical power and reduce the costs of experiments.

  9. Reliability Testing the Die-Attach of CPV Cell Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Bosco, N.; Sweet, C.; Kurtz, S.

    2011-02-01

    Results and progress are reported for a course of work to establish an efficient reliability test for the die-attach of CPV cell assemblies. Test vehicle design consists of a ~1 cm2 multijunction cell attached to a substrate via several processes. A thermal cycling sequence is developed in a test-to-failure protocol. Methods of detecting a failed or failing joint are prerequisite for this work; therefore both in-situ and non-destructive methods, including infrared imaging techniques, are being explored as a method to quickly detect non-ideal or failing bonds.

  10. Pressure locking test results

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1996-12-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.{close_quotes} Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; the authors will publish the results of their thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions.

  11. Pressure locking test results

    International Nuclear Information System (INIS)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D.

    1996-01-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, open-quotes Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.close quotes Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; we will publish the results of our thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions

  12. Test-retest reliability for aerodynamic measures of voice.

    Science.gov (United States)

    Awan, Shaheen N; Novaleski, Carolyn K; Yingling, Julie R

    2013-11-01

    The purpose of this study was to investigate the intrasubject reliability of aerodynamic characteristics of the voice within typical/normal speakers across testing sessions using the Phonatory Aerodynamic System (PAS 6600; KayPENTAX, Montvale, NJ). Participants were 60 healthy young adults (30 males and 30 females) between the ages 18 and 31 years with perceptually typical voice. Participants were tested using the PAS 6600 (Phonatory Aerodynamic System) on two separate days with approximately 1 week between each session at approximately the same time of day. Four PAS protocols were conducted (vital capacity, maximum sustained phonation, comfortable sustained phonation, and voicing efficiency) and measures of expiratory volume, maximum phonation time, mean expiratory airflow (during vowel production) and target airflow (obtained via syllable repetition), peak air pressure, aerodynamic power, aerodynamic resistance, and aerodynamic efficiency were obtained during each testing session. Associated acoustic measures of vocal intensity and frequency were also collected. All phonations were elicited at comfortable pitch and loudness. All aerodynamic and associated variables evaluated in this study showed useable test-retest reliability (ie, intraclass correlation coefficients [ICCs] ≥ 0.60). A high degree of mean test-retest reliability was found across all subjects for aerodynamic and associated acoustic measurements of vital capacity, maximum sustained phonation, glottal resistance, and vocal intensity (all with ICCs > 0.75). Although strong ICCs were observed for measures of glottal power and mean expiratory airflow in males, weaker overall results for these measures (ICC range: 0.60-0.67) were observed in females subjects and sizable coefficients of variation were observed for measures of power, resistance, and efficiency in both men and women. Differences in degree of reliability from measure to measure were revealed in greater detail using methods such as ICCs and

  13. A Reliability Test of a Complex System Based on Empirical Likelihood

    OpenAIRE

    Zhou, Yan; Fu, Liya; Zhang, Jun; Hui, Yongchang

    2016-01-01

    To analyze the reliability of a complex system described by minimal paths, an empirical likelihood method is proposed to solve the reliability test problem when the subsystem distributions are unknown. Furthermore, we provide a reliability test statistic of the complex system and extract the limit distribution of the test statistic. Therefore, we can obtain the confidence interval for reliability and make statistical inferences. The simulation studies also demonstrate the theorem results.

  14. Enhancing reliability of ultrasonic testing of welds of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Shcherbinskij, V.G.

    1981-01-01

    Results of investigation of factors influencing the reliability of manual ultrasonic testing of welded joints and weld deposited metal power-generating equipment are presented. Recommendations on the enhancing of reliability are given [ru

  15. Validity and Reliability of the Arabic Token Test for Children

    Science.gov (United States)

    Alkhamra, Rana A.; Al-Jazi, Aya B.

    2016-01-01

    Background: The Token Test for Children (2nd edition) (TTFC) is a measure for assessing receptive language. In this study we describe the translation process, validity and reliability of the Arabic Token Test for Children (A-TTFC). Aims: The aim of this study is to translate, validate and establish the reliability of the Arabic Token Test for…

  16. Conceptualizing Essay Tests' Reliability and Validity: From Research to Theory

    Science.gov (United States)

    Badjadi, Nour El Imane

    2013-01-01

    The current paper on writing assessment surveys the literature on the reliability and validity of essay tests. The paper aims to examine the two concepts in relationship with essay testing as well as to provide a snapshot of the current understandings of the reliability and validity of essay tests as drawn in recent research studies. Bearing in…

  17. Construction of Valid and Reliable Test for Assessment of Students

    Science.gov (United States)

    Osadebe, P. U.

    2015-01-01

    The study was carried out to construct a valid and reliable test in Economics for secondary school students. Two research questions were drawn to guide the establishment of validity and reliability for the Economics Achievement Test (EAT). It is a multiple choice objective test of five options with 100 items. A sample of 1000 students was randomly…

  18. Test-retest reliability of the Work Ability Index questionnaire

    NARCIS (Netherlands)

    de Zwart, B. C. H.; Frings-Dresen, M. H. W.; Van Duivenbooden, J. C.

    2002-01-01

    The goal of the study was to assess the test-retest reliability of the Work Ability Index (WAI) questionnaire. Reliability was tested using a test-retest design with a 4 week interval between measurements. Valid data were collected among 97 elderly construction workers aged 40 years and older. We

  19. Smallest detectable change and test-retest reliability of a self-reported outcome measure: Results of the Center for Epidemiologic Studies Depression Scale, General Self-Efficacy Scale, and 12-item General Health Questionnaire.

    Science.gov (United States)

    Ohno, Shotaro; Takahashi, Kana; Inoue, Aimi; Takada, Koki; Ishihara, Yoshiaki; Tanigawa, Masaru; Hirao, Kazuki

    2017-12-01

    This study aims to examine the smallest detectable change (SDC) and test-retest reliability of the Center for Epidemiologic Studies Depression Scale (CES-D), General Self-Efficacy Scale (GSES), and 12-item General Health Questionnaire (GHQ-12). We tested 154 young adults at baseline and 2 weeks later. We calculated the intra-class correlation coefficients (ICCs) for test-retest reliability with a two-way random effects model for agreement. We then calculated the standard error of measurement (SEM) for agreement using the ICC formula. The SEM for agreement was used to calculate SDC values at the individual level (SDC ind ) and group level (SDC group ). The study participants included 137 young adults. The ICCs for all self-reported outcome measurement scales exceeded 0.70. The SEM of CES-D was 3.64, leading to an SDC ind of 10.10 points and SDC group of 0.86 points. The SEM of GSES was 1.56, leading to an SDC ind of 4.33 points and SDC group of 0.37 points. The SEM of GHQ-12 with bimodal scoring was 1.47, leading to an SDC ind of 4.06 points and SDC group of 0.35 points. The SEM of GHQ-12 with Likert scoring was 2.44, leading to an SDC ind of 6.76 points and SDC group of 0.58 points. To confirm that the change was not a result of measurement error, a score of self-reported outcome measurement scales would need to change by an amount greater than these SDC values. This has important implications for clinicians and epidemiologists when assessing outcomes. © 2017 John Wiley & Sons, Ltd.

  20. Proving test on the reliability for nuclear valves

    International Nuclear Information System (INIS)

    Kajiyama, Yasuo; Tashiro, Hisao; Uga, Takeo; Maeda, Shunichi.

    1986-01-01

    Since valves are the most common components, they could be the most frequent causes of troubles in nuclear power plants. This proving test, therefore, has an important meaning to examine and verify the reliability of various valves under simulating conditions of abnormal and transient operations of the nuclear power plant. The test was performed mainly for the various types and pressure ratings of valves which were used in the primary and secondary systems in BWR and PWR nuclear power plants and which had major operating or safety related functions in those nuclear power plants. The results of the proving test, confirmed for more than four years, showed relatively favourable performance of the tested valves. It is concluded that performances of valves including operability, seat sealing and structural integrity were proved under the thermal cycling, vibration and pipe reaction load conditions. Operating functions during and after accident such as loss of coolant accident were satisfactory. From these results, it was considered that the purpose of this proving test was satisfactorily fulfilled. Several data accumulated by the test would be useful to get better reliability if it was evaluated with the actually experienced data of valves in the nuclear power plants. (Nogami, K.)

  1. Reliability of two social cognition tests: The combined stories test and the social knowledge test.

    Science.gov (United States)

    Thibaudeau, Élisabeth; Cellard, Caroline; Legendre, Maxime; Villeneuve, Karèle; Achim, Amélie M

    2018-04-01

    Deficits in social cognition are common in psychiatric disorders. Validated social cognition measures with good psychometric properties are necessary to assess and target social cognitive deficits. Two recent social cognition tests, the Combined Stories Test (COST) and the Social Knowledge Test (SKT), respectively assess theory of mind and social knowledge. Previous studies have shown good psychometric properties for these tests, but the test-retest reliability has never been documented. The aim of this study was to evaluate the test-retest reliability and the inter-rater reliability of the COST and the SKT. The COST and the SKT were administered twice to a group of forty-two healthy adults, with a delay of approximately four weeks between the assessments. Excellent test-retest reliability was observed for the COST, and a good test-retest reliability was observed for the SKT. There was no evidence of practice effect. Furthermore, an excellent inter-rater reliability was observed for both tests. This study shows a good reliability of the COST and the SKT that adds to the good validity previously reported for these two tests. These good psychometrics properties thus support that the COST and the SKT are adequate measures for the assessment of social cognition. Copyright © 2018. Published by Elsevier B.V.

  2. Results from the LHC Beam Dump Reliability Run

    CERN Document Server

    Uythoven, J; Carlier, E; Castronuovo, F; Ducimetière, L; Gallet, E; Goddard, B; Magnin, N; Verhagen, H

    2008-01-01

    The LHC Beam Dumping System is one of the vital elements of the LHC Machine Protection System and has to operate reliably every time a beam dump request is made. Detailed dependability calculations have been made, resulting in expected rates for the different system failure modes. A 'reliability run' of the whole system, installed in its final configuration in the LHC, has been made to discover infant mortality problems and to compare the occurrence of the measured failure modes with their calculations.

  3. Automatically generated acceptance test: A software reliability experiment

    Science.gov (United States)

    Protzel, Peter W.

    1988-01-01

    This study presents results of a software reliability experiment investigating the feasibility of a new error detection method. The method can be used as an acceptance test and is solely based on empirical data about the behavior of internal states of a program. The experimental design uses the existing environment of a multi-version experiment previously conducted at the NASA Langley Research Center, in which the launch interceptor problem is used as a model. This allows the controlled experimental investigation of versions with well-known single and multiple faults, and the availability of an oracle permits the determination of the error detection performance of the test. Fault interaction phenomena are observed that have an amplifying effect on the number of error occurrences. Preliminary results indicate that all faults examined so far are detected by the acceptance test. This shows promise for further investigations, and for the employment of this test method on other applications.

  4. The Reliability of a Functional Agility Test for Water Polo

    Directory of Open Access Journals (Sweden)

    Tucher Guilherme

    2014-07-01

    Full Text Available Few functional agility tests for water polo take into consideration its specific characteristics. The preliminary objective of this study was to evaluate the reliability of an agility test for water polo players. Fifteen players (16.3 ± 1.8 years old with a minimum of two years of competitive experience were evaluated. A Functional Test for Agility Performance (FTAP was designed to represent the context of this sport. Several trials were performed to familiarize the athlete with the movement. Two experienced coaches measured three repetitions of the FTAP. Descriptive statistics, repeated measures analysis of variance (ANOVA, 95% limit of agreement (LOA, intraclass correlation coefficient (ICC and standard error of measurements (SEM were used for data analysis. It was considered that certain criteria of reliability measures were met. There was no significant difference between the repetitions, which may be explained by an effect of the evaluator, the ability of the players or fatigue (p > 0.05. The ICC average from evaluators was high (0.88. The SEM varied between 0.13 s and 0.49 s. The CV average considering each individual was near 6-7%. These values depended on the condition of measurement. As the FTAP contains some characteristics that create a degree of unpredictability, the same athlete may reach different performance results, increasing variability. An adjustment in the sample, familiarization and careful selection of subjects help to improve this situation and enhance the reliability of the indicators.

  5. Validity and Reliability of a Medicine Ball Explosive Power Test.

    Science.gov (United States)

    Stockbrugger, Barry A.; Haennel, Robert G.

    2001-01-01

    Evaluated the validity and reliability of a medicine ball throw test to evaluate explosive power. Data on competitive sand volleyball players who performed a medicine ball throw and a standard countermovement jump indicated that the medicine ball throw test was a valid and reliable way to assess explosive power for an analogous total-body movement…

  6. Final report : testing and evaluation for solar hot water reliability.

    Energy Technology Data Exchange (ETDEWEB)

    Caudell, Thomas P. (University of New Mexico, Albuquerque, NM); He, Hongbo (University of New Mexico, Albuquerque, NM); Menicucci, David F. (Building Specialists, Inc., Albuquerque, NM); Mammoli, Andrea A. (University of New Mexico, Albuquerque, NM); Burch, Jay (National Renewable Energy Laboratory, Golden CO)

    2011-07-01

    Solar hot water (SHW) systems are being installed by the thousands. Tax credits and utility rebate programs are spurring this burgeoning market. However, the reliability of these systems is virtually unknown. Recent work by Sandia National Laboratories (SNL) has shown that few data exist to quantify the mean time to failure of these systems. However, there is keen interest in developing new techniques to measure SHW reliability, particularly among utilities that use ratepayer money to pay the rebates. This document reports on an effort to develop and test new, simplified techniques to directly measure the state of health of fielded SHW systems. One approach was developed by the National Renewable Energy Laboratory (NREL) and is based on the idea that the performance of the solar storage tank can reliably indicate the operational status of the SHW systems. Another approach, developed by the University of New Mexico (UNM), uses adaptive resonance theory, a type of neural network, to detect and predict failures. This method uses the same sensors that are normally used to control the SHW system. The NREL method uses two additional temperature sensors on the solar tank. The theories, development, application, and testing of both methods are described in the report. Testing was performed on the SHW Reliability Testbed at UNM, a highly instrumented SHW system developed jointly by SNL and UNM. The two methods were tested against a number of simulated failures. The results show that both methods show promise for inclusion in conventional SHW controllers, giving them advanced capability in detecting and predicting component failures.

  7. CCTF CORE I test results

    International Nuclear Information System (INIS)

    Murao, Yoshio; Sudoh, Takashi; Akimoto, Hajime; Iguchi, Tadashi; Sugimoto, Jun; Fujiki, Kazuo; Hirano, Kenmei

    1982-07-01

    This report presents the results of the following CCTF CORE I tests conducted in FY. 1980. (1) Multi-dimensional effect test, (2) Evaluation model test, (3) FLECHT coupling test. On the first test, one-dimensional treatment of the core thermohydrodynamics was discussed. On the second and third tests, the test results were compared with the results calculated by the evaluation model codes and the results of the corresponding FLECHT-SET test (Run 2714B), respectively. The work was performed under contracts with the Atomic Energy Bureau of Science and Technology Agency of Japan. (author)

  8. Design for reliability: NASA reliability preferred practices for design and test

    Science.gov (United States)

    Lalli, Vincent R.

    1994-01-01

    This tutorial summarizes reliability experience from both NASA and industry and reflects engineering practices that support current and future civil space programs. These practices were collected from various NASA field centers and were reviewed by a committee of senior technical representatives from the participating centers (members are listed at the end). The material for this tutorial was taken from the publication issued by the NASA Reliability and Maintainability Steering Committee (NASA Reliability Preferred Practices for Design and Test. NASA TM-4322, 1991). Reliability must be an integral part of the systems engineering process. Although both disciplines must be weighed equally with other technical and programmatic demands, the application of sound reliability principles will be the key to the effectiveness and affordability of America's space program. Our space programs have shown that reliability efforts must focus on the design characteristics that affect the frequency of failure. Herein, we emphasize that these identified design characteristics must be controlled by applying conservative engineering principles.

  9. Systems reliability Benchmark exercise part 1-Description and results

    International Nuclear Information System (INIS)

    Amendola, A.

    1986-01-01

    The report describes aims, rules and results of the Systems Reliability Benchmark Exercise, which has been performed in order to assess methods and procedures for reliability analysis of complex systems and involved a large number of European organizations active in NPP safety evaluation. The exercise included both qualitative and quantitative methods and was structured in such a way that separation of the effects of uncertainties in modelling and in data on the overall spread was made possible. Part I describes the way in which RBE has been performed, its main results and conclusions

  10. Reliability Analysis and Test Planning using CAPO-Test for Existing Structures

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Engelund, S.; Faber, Michael Havbro

    2000-01-01

    Evaluation of the reliability of existing concrete structures often requires that the compressive strength of the concrete is estimated on the basis of tests performed with concrete samples from the structure considered. In this paper the CAPO-test method is considered. The different sources...... of uncertainty related to this method are described. It is shown how the uncertainty in the transformation from the CAPO-test results to estimates of the concrete strength can be modeled. Further, the statistical uncertainty is modeled using Bayesian statistics. Finally, it is shown how reliability-based optimal...... planning of CAPO-tests can be performed taking into account the expected costs due to the CAPO-tests and possible repair or failure of the structure considered. An illustrative example is presented where the CAPO-test is compared with conventional concrete cylinder compression tests performed on cores...

  11. Construction and Evaluation of Reliability and Validity of Reasoning Ability Test

    Science.gov (United States)

    Bhat, Mehraj A.

    2014-01-01

    This paper is based on the construction and evaluation of reliability and validity of reasoning ability test at secondary school students. In this paper an attempt was made to evaluate validity, reliability and to determine the appropriate standards to interpret the results of reasoning ability test. The test includes 45 items to measure six types…

  12. Reliability and Validity of the Inline Skating Skill Test

    Science.gov (United States)

    Radman, Ivan; Ruzic, Lana; Padovan, Viktoria; Cigrovski, Vjekoslav; Podnar, Hrvoje

    2016-01-01

    This study aimed to examine the reliability and validity of the inline skating skill test. Based on previous skating experience forty-two skaters (26 female and 16 male) were randomized into two groups (competitive level vs. recreational level). They performed the test four times, with a recovery time of 45 minutes between sessions. Prior to testing, the participants rated their skating skill using a scale from 1 to 10. The protocol included performance time measurement through a course, combining different skating techniques. Trivial changes in performance time between the repeated sessions were determined in both competitive females/males and recreational females/males (-1.7% [95% CI: -5.8–2.6%] – 2.2% [95% CI: 0.0–4.5%]). In all four subgroups, the skill test had a low mean within-individual variation (1.6% [95% CI: 1.2–2.4%] – 2.7% [95% CI: 2.1–4.0%]) and high mean inter-session correlation (ICC = 0.97 [95% CI: 0.92–0.99] – 0.99 [95% CI: 0.98–1.00]). The comparison of detected typical errors and smallest worthwhile changes (calculated as standard deviations × 0.2) revealed that the skill test was able to track changes in skaters’ performances. Competitive-level skaters needed shorter time (24.4–26.4%, all p skating skills in amateur competitive and recreational level skaters. Further studies are needed to evaluate the reproducibility of this skill test in different populations including elite inline skaters. Key points Study evaluated the reliability and construct validity of a newly developed inline skating skill test. Evaluated test is a first protocol designed to assess specific inline skating skill. Two groups of amateur skaters with different skating proficiency repeated the skill test in four separate occasions. The results suggest that evaluated test is reliable and valid to evaluate inline skating skill in amateur skaters. PMID:27803616

  13. Reliability, Validity and Factor Structure of Drug Abuse Screening Test

    Directory of Open Access Journals (Sweden)

    Sayed Hadi Sayed Alitabar

    2016-05-01

    Full Text Available Background and Objective: According to the increasing of substance use in the country, more researches about this phenomenon are necessary. This Study Investigates the Validity, Reliability and Confirmatory Factor Structure of the Drug Abuse Screening test (DAST. Materials and Methods: The Sample Consisted of 381 Patients (143 Women and 238 Men with a Multi-Stage Cluster Sampling of Areas 2, 6 and 12 of Tehran Were Selected from Each Region, 6 Randomly Selected Drug Rehabilitation Center. The DAST Was Used as Instrument. Divergent & Convergent Validity of this Scale Was Assessed with Problems Assessment for Substance Using Psychiatric Patients (PASUPP and Relapse Prediction Scale (RPS.Results: The DAST after the First Time Factor Structure of Using Confirmatory Factor Analysis Was Confirmed. The DAST Had a Good Internal Consistency (Cranach’s Alpha, and the Reliability of the Test Within a Week, 0.9, 0.8. Also this Scale Had a Positive Correlation with Problems Assessment for Substance Using Psychiatric Patients and Relapse Prediction Scale (P<0.01.Conclusion: The Overall Results Showed that the Drug Abuse Screening Test in Iranian Society Is Valid. It Can Be Said that Self-Report Scale Tool Is Useful for Research Purposes and Addiction.

  14. Reproducibility of the results in nondestructive testing

    International Nuclear Information System (INIS)

    Launay, J.P.; Chalaye, H.; Thomas, A.

    1980-10-01

    Pressure vessels must comply with very severe safety criteria. In order to ensure that the required quality is attained, non destructive tests are used and these have to be highly reliable: magnetoscopy and liquid penetration for surface examinations, radiography and ultrasonics for voluminal examinations. In the case of ultrasonic examinations, a study of parameters has been made and a statistical analysis of the results has made it possible to calculate the dispersion due to the testing equipment [fr

  15. IRT-Estimated Reliability for Tests Containing Mixed Item Formats

    Science.gov (United States)

    Shu, Lianghua; Schwarz, Richard D.

    2014-01-01

    As a global measure of precision, item response theory (IRT) estimated reliability is derived for four coefficients (Cronbach's a, Feldt-Raju, stratified a, and marginal reliability). Models with different underlying assumptions concerning test-part similarity are discussed. A detailed computational example is presented for the targeted…

  16. A Latent Class Approach to Estimating Test-Score Reliability

    Science.gov (United States)

    van der Ark, L. Andries; van der Palm, Daniel W.; Sijtsma, Klaas

    2011-01-01

    This study presents a general framework for single-administration reliability methods, such as Cronbach's alpha, Guttman's lambda-2, and method MS. This general framework was used to derive a new approach to estimating test-score reliability by means of the unrestricted latent class model. This new approach is the latent class reliability…

  17. Application of a truncated normal failure distribution in reliability testing

    Science.gov (United States)

    Groves, C., Jr.

    1968-01-01

    Statistical truncated normal distribution function is applied as a time-to-failure distribution function in equipment reliability estimations. Age-dependent characteristics of the truncated function provide a basis for formulating a system of high-reliability testing that effectively merges statistical, engineering, and cost considerations.

  18. Face Perception and Test Reliabilities in Congenital Prosopagnosia in Seven Tests

    Directory of Open Access Journals (Sweden)

    Janina Esins

    2016-01-01

    Full Text Available Congenital prosopagnosia, the innate impairment in recognizing faces, is a very heterogeneous disorder with different phenotypical manifestations. To investigate the nature of prosopagnosia in more detail, we tested 16 prosopagnosics and 21 controls with an extended test battery addressing various aspects of face recognition. Our results show that prosopagnosics exhibited significant impairments in several face recognition tasks: impaired holistic processing (they were tested amongst others with the Cambridge Face Memory Test (CFMT as well as reduced processing of configural information of faces. This test battery also revealed some new findings. While controls recognized moving faces better than static faces, prosopagnosics did not exhibit this effect. Furthermore, prosopagnosics had significantly impaired gender recognition—which is shown on a groupwise level for the first time in our study. There was no difference between groups in the automatic extraction of face identity information or in object recognition as tested with the Cambridge Car Memory Test. In addition, a methodological analysis of the tests revealed reduced reliability for holistic face processing tests in prosopagnosics. To our knowledge, this is the first study to show that prosopagnosics showed a significantly reduced reliability coefficient (Cronbach’s alpha in the CFMT compared to the controls. We suggest that compensatory strategies employed by the prosopagnosics might be the cause for the vast variety of response patterns revealed by the reduced test reliability. This finding raises the question whether classical face tests measure the same perceptual processes in controls and prosopagnosics.

  19. Reliability of psychophysiological responses across multiple motion sickness stimulation tests

    Science.gov (United States)

    Stout, C. S.; Toscano, W. B.; Cowings, P. S.

    1995-01-01

    Although there is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation, very little evidence exists that examines the reproducibility of autonomic responses within subjects during motion sickness stimulation. Our objectives were to examine the reliability of autonomic responses and symptom levels across five testing occasions using the (1) final minute of testing, (2) change in autonomic response and the change in symptom level, and (3) strength of the relationship between the change in symptom level and the change in autonomic responses across the entire motion sickness test. The results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and symptoms throughout the test duration are less stable across the tests. Finally, autonomic responses and symptom levels are significantly related across the entire motion sickness test.

  20. Test-retest reliability and predictive validity of the Implicit Association Test in children.

    Science.gov (United States)

    Rae, James R; Olson, Kristina R

    2018-02-01

    The Implicit Association Test (IAT) is increasingly used in developmental research despite minimal evidence of whether children's IAT scores are reliable across time or predictive of behavior. When test-retest reliability and predictive validity have been assessed, the results have been mixed, and because these studies have differed on many factors simultaneously (lag-time between testing administrations, domain, etc.), it is difficult to discern what factors may explain variability in existing test-retest reliability and predictive validity estimates. Across five studies (total N = 519; ages 6- to 11-years-old), we manipulated two factors that have varied in previous developmental research-lag-time and domain. An internal meta-analysis of these studies revealed that, across three different methods of analyzing the data, mean test-retest (rs of .48, .38, and .34) and predictive validity (rs of .46, .20, and .10) effect sizes were significantly greater than zero. While lag-time did not moderate the magnitude of test-retest coefficients, whether we observed domain differences in test-retest reliability and predictive validity estimates was contingent on other factors, such as how we scored the IAT or whether we included estimates from a unique sample (i.e., a sample containing gender typical and gender diverse children). Recommendations are made for developmental researchers that utilize the IAT in their research. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  1. Test re-test reliability and construct validity of the star-track test of manual dexterity

    DEFF Research Database (Denmark)

    Kildebro, Niels; Amirian, Ilda; Gögenur, Ismail

    2015-01-01

    Objectives. We wished to determine test re-test reliability and construct validity of the star-track test of manual dexterity. Design. Test re-test reliability was examined in a controlled study. Construct validity was tested in a blinded randomized crossover study. Setting. The study was performed...... at a university hospital in Denmark. Participants. A total of 11 subjects for test re-test and 20 subjects for the construct validity study were included. All subjects were healthy volunteers. Intervention. The test re-test trial had two measurements with 2 days pause in between. The interventions...... in the construct validity study included baseline measurement, intervention 1: fatigue, intervention 2: stress, and intervention 3: fatigue and stress. There was a 2 day pause between each intervention. Main outcome measure. An integrated measure of completion time and number of errors was used. Results. All...

  2. Automation of testing the metrological reliability of nondestructive control systems

    International Nuclear Information System (INIS)

    Zhukov, Yu.A.; Isakov, V.B.; Karlov, Yu.K.; Kovalevskij, Yu.A.

    1987-01-01

    Opportunities of microcomputers are used to solve the problem of testing control-measuring systems. Besides the main program the program of data processing when characterizing the nondestructive control systems is written in the microcomputer. The program includes two modules. The first module contains tests-programs, by which accuracy of functional elements of the microcomputer and interface elements with issuing a message to the operator on readiness of the elements for operation and failure of a certain element are determined. The second module includes: calculational programs when determining metrological reliability of measuring channel reliability, a calculational subprogram for random statistical measuring error, time instability and ''dead time''. Automation of testing metrological reliability of the nondestructive control systems increases reliability of determining metrological parameters and reduces time of system testing

  3. Validity, Reliability, and Sensitivity of a Volleyball Intermittent Endurance Test.

    Science.gov (United States)

    Rodríguez-Marroyo, Jose A; Medina-Carrillo, Javier; García-López, Juan; Morante, Juan C; Villa, José G; Foster, Carl

    2017-03-01

    To analyze the concurrent and construct validity of a volleyball intermittent endurance test (VIET). The VIET's test-retest reliability and sensitivity to assess seasonal changes was also studied. During the preseason, 71 volleyball players of different competitive levels took part in this study. All performed the VIET and a graded treadmill test with gas-exchange measurement (GXT). Thirty-one of the players performed an additional VIET to analyze the test-retest reliability. To test the VIET's sensitivity, 28 players repeated the VIET and GXT at the end of their season. Significant (P volleyball players.

  4. Re-test reliability of gustatory testing and introduction of the sensitive Taste-Drop-Test

    DEFF Research Database (Denmark)

    Fjaeldstad, A; Niklassen, A; Fernandes, H

    2018-01-01

    . Testing gustatory function can be important for diagnostics and assessment of treatment effects. However, the gustatory tests applied are required to be both sensitive and reliable.In this study, we investigate the re-test validity of popular Taste Strips gustatory test for gustatory screening....... Furthermore, we introduce a new sensitive Taste-Drop-Test, which was found to be superior for detecting a more accurate measure of tastant sensitivity....

  5. NASA reliability preferred practices for design and test

    Science.gov (United States)

    1991-01-01

    Given here is a manual that was produced to communicate within the aerospace community design practices that have contributed to NASA mission success. The information represents the best technical advice that NASA has to offer on reliability design and test practices. Topics covered include reliability practices, including design criteria, test procedures, and analytical techniques that have been applied to previous space flight programs; and reliability guidelines, including techniques currently applied to space flight projects, where sufficient information exists to certify that the technique will contribute to mission success.

  6. Reliability demonstration test planning: A three dimensional consideration

    International Nuclear Information System (INIS)

    Yadav, Om Prakash; Singh, Nanua; Goel, Parveen S.

    2006-01-01

    Increasing customer demand for reliability, fierce market competition on time-to-market and cost, and highly reliable products are making reliability testing more challenging task. This paper presents a systematic approach for identifying critical elements (subsystems and components) of the system and deciding the types of test to be performed to demonstrate reliability. It decomposes the system into three dimensions (i.e. physical, functional and time) and identifies critical elements in the design by allocating system level reliability to each candidate. The decomposition of system level reliability is achieved by using criticality index. The numerical value of criticality index for each candidate is derived based on the information available from failure mode and effects analysis (FMEA) document or warranty data from a prior system. It makes use of this information to develop reliability demonstration test plan for the identified (critical) failure mechanisms and physical elements. It also highlights the benefits of using prior information in order to locate critical spots in the design and in subsequent development of test plans. A case example is presented to demonstrate the proposed approach

  7. A REVIEW OF SINGLE SPECIES TOXICITY TESTS: ARE THE TESTS RELIABLE PREDICTORS OF AQUATIC ECOSYSTEM COMMUNITY RESPONSES?

    Science.gov (United States)

    This document provides a comprehensive review to evaluate the reliability of indicator species toxicity test results in predicting aquatic ecosystem impacts, also called the ecological relevance of laboratory single species toxicity tests.

  8. Operational reliability testing of FBR fuel in EBR-II

    International Nuclear Information System (INIS)

    Asaga, Takeo; Ukai, Shigeharu; Nomura, Shigeo; Shikakura, Sakae

    1991-01-01

    The operational reliability testing of FBR fuel has been conducting in EBR-II as a DOE/PNC collaboration program. This paper reviews the achieved summary of Phase-I test as well as outline of progressing Phase-II test. In Phase-I test, the reliability of FBR fuel pins including 'MONJU' fuel was demonstrated at the event of operational transient. Continued operation of the failed pins was also shown to be feasible without affecting the plant operation. The objectives of the Phase-II test is to extend the data base relating with the operational reliability for long life fuel, and to supply the highly quantitative evaluation. The valuable insight obtained in Phase-II test are considerably expected to be useful toward the achievement of commercial FBR. (author)

  9. Optimal number of tests to achieve and validate product reliability

    International Nuclear Information System (INIS)

    Ahmed, Hussam; Chateauneuf, Alaa

    2014-01-01

    The reliability validation of engineering products and systems is mandatory for choosing the best cost-effective design among a series of alternatives. Decisions at early design stages have a large effect on the overall life cycle performance and cost of products. In this paper, an optimization-based formulation is proposed by coupling the costs of product design and validation testing, in order to ensure the product reliability with the minimum number of tests. This formulation addresses the question about the number of tests to be specified through reliability demonstration necessary to validate the product under appropriate confidence level. The proposed formulation takes into account the product cost, the failure cost and the testing cost. The optimization problem can be considered as a decision making system according to the hierarchy of structural reliability measures. The numerical examples show the interest of coupling design and testing parameters. - Highlights: • Coupled formulation for design and testing costs, with lifetime degradation. • Cost-effective testing optimization to achieve reliability target. • Solution procedure for nested aleatoric and epistemic variable spaces

  10. OPTIMUM DESIGN OF EXPERIMENTS FOR ACCELERATED RELIABILITY TESTING

    Directory of Open Access Journals (Sweden)

    Sebastian Marian ZAHARIA

    2014-05-01

    Full Text Available In this paper is presented a case study that demonstrates how design to experiments (DOE information can be used to design better accelerated reliability tests. In the case study described in this paper, will be done a comparison and optimization between main accelerated reliability test plans (3 Level Best Standard Plan, 3 Level Best Compromise Plan, 3 Level Best Equal Expected Number Failing Plan, 3 Level 4:2:1 Allocation Plan. Before starting an accelerated reliability test, it is advisable to have a plan that helps in accurately estimating reliability at operating conditions while minimizing test time and costs. A test plan should be used to decide on the appropriate stress levels that should be used (for each stress type and the amount of the test units that need to be allocated to the different stress levels (for each combination of the different stress types' levels. For the case study it used ALTA 7 software what provides a complete analysis for data from accelerated reliability tests

  11. Reliability of four experimental mechanical pain tests in children

    DEFF Research Database (Denmark)

    Søe, Ann-Britt Langager; Thomsen, Lise L; Tornoe, Birte

    2013-01-01

    In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT) in healthy children. Furthermore, the aim was a...... was also to study the intersession reliability of the following four tests: (1) Total Tenderness Score; (2) PPT; (3) Visual Analog Scale score at suprapressure pain threshold; and (4) area under the curve (stimulus-response functions for pressure versus pain).......In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT) in healthy children. Furthermore, the aim...

  12. Reliability of candida skin test in the evaluation of T-cell function in ...

    African Journals Online (AJOL)

    Background: Both standardized and non-standardized candida skin tests are used in clinical practice for functional in-vivo assessment of cellular immunity with variable results and are considered not reliable under the age of 1 year. We sought to investigate the reliability of using manually prepared candida intradermal test ...

  13. The Test-Retest Reliability of New Generation Power Indices of Wingate All-Out Test

    Directory of Open Access Journals (Sweden)

    Ozgur Ozkaya

    2018-04-01

    Full Text Available Although reliability correlations of traditional power indices of the Wingate test have been well documented, no study has analyzed new generation power indices based on milliseconds obtained from a Peak Bike. The purpose of this study was to investigate the retest reliability of new generation power indices. Thirty-two well-trained male athletes who were specialized in basketball, football, tennis, or track and field volunteered to take part in the study (age: 24.3 ± 2.2 years; body mass: 77 ± 8.3 kg; height: 180.3 ± 6.3 cm. Participants performed two Wingate all-out sessions on two separate days. Intra-class correlation coefficient (ICC, standard error measurement (SEM, smallest real differences (SRD and coefficient of variation (CV scores were analyzed based on the test and retest data. Reliability results of traditional power indices calculated based on 5-s means such as peak power, average power, power drop, and fatigue index ratio were similar with the previous findings in literature (ICC ≥ 0.94; CV ≤ 2.8%; SEM ≤ 12.28; SRD% ≤ 7.7%. New generation power indices such as peak power, average power, lowest power, power drop, fatigue index, power decline, maximum speed as rpm, and amount of total energy expenditure demonstrated high reliability (ICC ≥ 0.94; CV ≤ 4.3%; SEM ≤ 10.36; SRD% ≤ 8.8%. Time to peak power, time at maximum speed, and power at maximum speed showed a moderate level of reliability (ICC ≥ 0.73; CV ≤ 8.9%; SEM ≤ 63.01; SRD% ≤ 22.4%. The results of this study indicate that reliability correlations and SRD% of new generation power and fatigue-related indices are similar with traditional 5-s means. However, new time-related indices are very sensitive and moderately reliable.

  14. MITG test procedure and results

    International Nuclear Information System (INIS)

    Eck, M.E.; Mukunda, M.

    1983-01-01

    Elements and modules for Radioisotope Thermoelectric Generator have been performance tested since the inception of the RTG program. These test articles seldom resembled flight hardware and often lacked adequate diagnostic instrumentation. Because of this, performance problems were not identified in the early stage of program development. The lack of test data in an unexpected area often hampered the development of a problem solution. A procedure for conducting the MITG Test was developed in an effort to obtain data in a systematic, unambiguous manner. This procedure required the development of extensive data acquisition software and test automation. The development of a facility to implement the test procedure, the facility hardware and software requirements, and the results of the MITG testing are the subject of this paper

  15. Test-retest reliability and validity of the Sniffin' TOM odor memory test.

    Science.gov (United States)

    Croy, Ilona; Zehner, Cora; Larsson, Maria; Zucco, Gesualdo M; Hummel, Thomas

    2015-03-01

    Few attempts have been made to develop an olfactory test that captures episodic retention of olfactory information. Assessment of episodic odor memory is of particular interest in aging and in the cognitively impaired as both episodic memory deficits and olfactory loss have been targeted as reliable hallmarks of cognitive decline and impending dementia. Here, 96 healthy participants (18-92 years) and an additional 19 older people with mild cognitive impairment were tested (73-82 years). Participants were presented with 8 common odors with intentional encoding instructions that were followed by a yes-no recognition test. After recognition completion, participants were asked to identify all odors by means of free or cued identification. A retest of the odor memory test (Sniffin' TOM = test of odor memory) took place 17 days later. The results revealed satisfactory test-retest reliability (0.70) of odor recognition memory. Both recognition and identification performance were negatively affected by age and more pronounced among the cognitively impaired. In conclusion, the present work presents a reliable, valid, and simple test of episodic odor recognition memory that may be used in clinical groups where both episodic memory deficits and olfactory loss are prevalent preclinically such as Alzheimer's disease. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Reliability of a New Lower-Extremity Motor Coordination Test

    Directory of Open Access Journals (Sweden)

    Antosiak-Cyrak Katarzyna

    2015-12-01

    Full Text Available Introduction. Motor coordination is a basic motor ability necessary for daily life, which also allows athletes to win a sports rivalry and patients to assess their recovery progress after therapy and rehabilitation. The aim of the present study was to assess the reliability of a new lower-extremity rate of movements test and testing apparatus.

  17. Test Re-Test Reliability of Four Versions of the 3-Cone Test in Non-Athletic Men

    Directory of Open Access Journals (Sweden)

    Jason G. Langley, Robert D. Chetlin

    2017-03-01

    Full Text Available Until recently, measurement and evaluation in sport science, especially agility testing, has not always included key elements of proper test construction. Often tests are published without reporting reliability and validity analysis for a specific population. The purpose of the present study was to examine the test re-test reliability of four versions of the 3-Cone Test (3CT, and provide guidance on proper test construction for testing agility in athletic populations. Forty male students enrolled in classes in the Department of Physical Education at a mid-Atlantic university participated. On each of test day participants performed 10 trials. In random order, they performed three trials to the right (3CTR, standard test, three to the left (3CTL, and two modified trials (3CTAR and 3CTAL, which included a reactive component in which a visual cue was given to indicate direction. Intra-class correlation coefficients (ICC indicated a moderate to high reliability for the four tests, 3CTR 0.79 (0.64-0.88, 95%CI, 3CTL 0.73 (0.55-0.85, 3CTAR 0.85(0.74-0.92, and 3CTAL 0.79 (0.64-0.88. Small standard error of the measurement (SEM was found; range 0.09 to 0.10. Pearson correlations between tests were high (0.82-0.92 on day one as well as day two (0.72-0.85. These results indicate each version of the 3-Cone Test is reliable; however, further tests are needed with specific athletic populations. Only the 3CTAR and 3CTAL are tests of agility due to the inclusion of a reactive component. Future studies examining agility testing and training should incorporate technological elements, including automated timing systems and motion capture analysis. Such instrumentation will allow for optimal design of tests that simulate sport-specific game conditions.

  18. Intertester reliability of the talk test in a cardiac rehabilitation population

    DEFF Research Database (Denmark)

    Petersen, Annemette Krintel; Maribo, Thomas; Hjortdal, Vibeke Elisabeth

    2013-01-01

    PURPOSE: The validity of the Talk Test (TT) is well documented, but the reliability of the test is not clear. The aim of this study was to assess the absolute and relative intertester reliability of the TT in cardiac patients. METHODS: Cardiac patients (n = 64) who had completed an exercise...... randomized to tests. Workload in watts at the first negative stage of the TT was registered as the test result. Patients and physiotherapists were blinded to test results of the first test. Absolute reliability of the TT was assessed with Bland-Altman plot, standard error of measurement, and minimal...... detectable change. Relative reliability was assessed using the intraclass correlation coefficient (ICC). RESULTS: Mean difference in peak workload between test and retest was 0.8 W (95% CI: -4.8 to 3.3). Limit of agreement was estimated to be +31/-32 W. Standard error of measurement was 11 W (95% CI: 10...

  19. Reliability performance testing of totally encapsulating chemical protective suits

    International Nuclear Information System (INIS)

    Johnson, J.S.; Swearengen, P.M.

    1991-01-01

    The need to assure a high degree of reliability for totally encapsulating chemical protective (TECP) suits has been recognized by Lawrence Livermore National Laboratory's (LLNL) Hazards Control Department for some time. The following four tests were proposed as necessary to provide complete evaluation of TECP suit performance: 1. Quantitative leak test (ASTM draft), 2. Worst-case chemical exposure test (conceptual), 3. Pressure leak-rate test (complete, ASTM F1057-87), and 4. Chemical leak-rate test (ASTM draft). This paper reports on these tests which should be applied to measuring TECP suit performance in two stages: design qualification tests and field use tests. Test 1, 2, and 3 are used as design qualification tests, and tests 3 and 4 are used as field use tests

  20. Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Pensinger, Stuart; Sargusingh, Miriam J.

    2014-01-01

    The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

  1. Reliability and results, but little room to manoeuvre

    International Nuclear Information System (INIS)

    Atkinson, Ian

    1994-01-01

    A wide variety of research programs to produce cost-effective and reliable inspection techniques have arisen following the discovery of stress corrosion cracks in the control rod drive mechanism of pressurized water reactors, notably in France, Belgium and Spain. This article describes the research program results from a cooperative partnership between Comex Nucleaire, Westinghouse Electric and AEA Technology. The package developed offers techniques to provide complete capability in virtually all the design configurations used world-wide. After extensive acceptance trials in France and the United States the techniques are now being used on site at Bugey 3. (UK)

  2. Large test rigs verify Clinch River control rod reliability

    International Nuclear Information System (INIS)

    Michael, H.D.; Smith, G.G.

    1983-01-01

    The purpose of the Clinch River control test programme was to use multiple full-scale prototypic control rod systems for verifying the system's ability to perform reliably during simulated reactor power control and emergency shutdown operations. Two major facilities, the Shutdown Control Rod and Maintenance (Scram) facility and the Dynamic and Seismic Test (Dast) facility, were constructed. The test programme of each facility is described. (UK)

  3. Demonstration test for reliability of valves for atomic power plants

    International Nuclear Information System (INIS)

    Hosaka, Shiro

    1978-01-01

    The demonstration test on the reliability of valves for atomic power plants being carried out by the Nuclear Engineering Test Center is reported. This test series is conducted as six-year project from FY 1976 to FY 1981 at the Isogo Test Center. The demonstration test consists of (1) environmental test, (2) reaction force test, (3) vibration test, (4) stress measurement test, (5) operational characteristic test, (6) flow resistance coefficient measuring test, (7) leakage test and (8) safety valve and relief valve test. These contents are explained about the special requirements for nuclear use, for example, the enviornmental condition after the design base accident of PWRs and BWRs, the environmental test sequence for isolation valves of containment vessels under the emergency condition, the seismic test condition for valves of nuclear use, the various stress measurements under thermal transient conditions, the leak test after 500 cycles between the normal operating conditions for PWRs and BWRs and the start up conditions and so on. As for the testing facilities, the whole flow diagram is shown, in which the environmental test section, the vibration test section, the steam test section, the hot water test section, the safety valve test section and main components are included. The specifications of each test section and main components are presented. (Nakai, Y.)

  4. Reliability of wind turbine blades: An overview of materials testing

    DEFF Research Database (Denmark)

    Holmes, John W.; Sørensen, Bent F.; Brøndsted, Povl

    2007-01-01

    an understanding of how damage develops in composite structures, composite materials and adhesives. Designing reliable wind turbine blades also requires the further development of laboratory scale and full scale test methods to evaluate the structural response and durability of new materials under various loading......The structural reliability of wind turbine components can have a profound impact on both the profitability and reputation of a wind turbine manufacturer or supplier of wind turbine components. The issue of reliability is of critical concern when large wind farm co-operatives are considered......, and when wind turbines are located in remote regions where the cost of inspections and repairs can be very high. From a structural viewpoint, wind turbine blades are subjected to very complex loading histories with coupled deformation modes. The long-term reliability of wind turbine blades requires...

  5. Engineering model cryocooler test results

    International Nuclear Information System (INIS)

    Skimko, M.A.; Stacy, W.D.; McCormick, J.A.

    1992-01-01

    This paper reports that recent testing of diaphragm-defined, Stirling-cycle machines and components has demonstrated cooling performance potential, validated the design code, and confirmed several critical operating characteristics. A breadboard cryocooler was rebuilt and tested from cryogenic to near-ambient cold end temperatures. There was a significant increase in capacity at cryogenic temperatures and the performance results compared will with code predictions at all temperatures. Further testing on a breadboard diaphragm compressor validated the calculated requirement for a minimum axial clearance between diaphragms and mating heads

  6. Test-retest reliability of infant event related potentials evoked by faces.

    Science.gov (United States)

    Munsters, N M; van Ravenswaaij, H; van den Boomen, C; Kemner, C

    2017-04-05

    Reliable measures are required to draw meaningful conclusions regarding developmental changes in longitudinal studies. Little is known, however, about the test-retest reliability of face-sensitive event related potentials (ERPs), a frequently used neural measure in infants. The aim of the current study is to investigate the test-retest reliability of ERPs typically evoked by faces in 9-10 month-old infants. The infants (N=31) were presented with neutral, fearful and happy faces that contained only the lower or higher spatial frequency information. They were tested twice within two weeks. The present results show that the test-retest reliability of the face-sensitive ERP components is moderate (P400 and Nc) to substantial (N290). However, there is low test-retest reliability for the effects of the specific experimental manipulations (i.e. emotion and spatial frequency) on the face-sensitive ERPs. To conclude, in infants the face-sensitive ERP components (i.e. N290, P400 and Nc) show adequate test-retest reliability, but not the effects of emotion and spatial frequency on these ERP components. We propose that further research focuses on investigating elements that might increase the test-retest reliability, as adequate test-retest reliability is necessary to draw meaningful conclusions on individual developmental trajectories of the face-sensitive ERPs in infants. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Reliability test and failure analysis of high power LED packages

    International Nuclear Information System (INIS)

    Chen Zhaohui; Zhang Qin; Wang Kai; Luo Xiaobing; Liu Sheng

    2011-01-01

    A new type application specific light emitting diode (LED) package (ASLP) with freeform polycarbonate lens for street lighting is developed, whose manufacturing processes are compatible with a typical LED packaging process. The reliability test methods and failure criterions from different vendors are reviewed and compared. It is found that test methods and failure criterions are quite different. The rapid reliability assessment standards are urgently needed for the LED industry. 85 0 C/85 RH with 700 mA is used to test our LED modules with three other vendors for 1000 h, showing no visible degradation in optical performance for our modules, with two other vendors showing significant degradation. Some failure analysis methods such as C-SAM, Nano X-ray CT and optical microscope are used for LED packages. Some failure mechanisms such as delaminations and cracks are detected in the LED packages after the accelerated reliability testing. The finite element simulation method is helpful for the failure analysis and design of the reliability of the LED packaging. One example is used to show one currently used module in industry is vulnerable and may not easily pass the harsh thermal cycle testing. (semiconductor devices)

  8. Reliability and maintainability data acquisition in equipment development tests

    International Nuclear Information System (INIS)

    Haire, M.J.; Gift, E.H.

    1983-10-01

    The need for collection of reliability, maintainability, and availability data adds a new dimension to the data acquisition requirements of equipment development tests. This report describes the reliability and maintainability data that are considered necessary to ensure that sufficient and high quality data exist for a comprehensive, quantitative evaluation of equipment and system availability. These necessary data are presented as a set of data collection forms. Three data acquisition forms are discussed: an inventory and technical data form, which is filed by the design engineer when the design is finished or the equipment is received; an event report form, which is completed by the senior test operator at each shutdown; and a maintainability report, which is a collaborative effort between senior operators and lead engineers and is completed on restart. In addition, elements of a reliability, maintainability evaluation program are described. Emphasis is placed on the role of data, its storage, and use in such a program

  9. Test-retest reliability of the multifocal photopic negative response.

    Science.gov (United States)

    Van Alstine, Anthony W; Viswanathan, Suresh

    2017-02-01

    To assess the test-retest reliability of the multifocal photopic negative response (mfPhNR) of normal human subjects. Multifocal electroretinograms were recorded from one eye of 61 healthy adult subjects on two separate days using a Visual Evoked Response Imaging System software version 4.3 (EDI, San Mateo, California). The visual stimulus delivered on a 75-Hz monitor consisted of seven equal-sized hexagons each subtending 12° of visual angle. The m-step exponent was 9, and the m-sequence was slowed to include at least 30 blank frames after each flash. Only the first slice of the first-order kernel was analyzed. The mfPhNR amplitude was measured at a fixed time in the trough from baseline (BT) as well as at the same fixed time in the trough from the preceding b-wave peak (PT). Additionally, we also analyzed BT normalized either to PT (BT/PT) or to the b-wave amplitude (BT/b-wave). The relative reliability of test-retest differences for each test location was estimated by the Wilcoxon matched-pair signed-rank test and intraclass correlation coefficients (ICC). Absolute test-retest reliability was estimated by Bland-Altman analysis. The test-retest amplitude differences for neither of the two measurement techniques were statistically significant as determined by Wilcoxon matched-pair signed-rank test. PT measurements showed greater ICC values than BT amplitude measurements for all test locations. For each measurement technique, the ICC value of the macular response was greater than that of the surrounding locations. The mean test-retest difference was close to zero for both techniques at each of the test locations, and while the coefficient of reliability (COR-1.96 times the standard deviation of the test-retest difference) was comparable for the two techniques at each test location when expressed in nanovolts, the %COR (COR normalized to the mean test and retest amplitudes) was superior for PT than BT measurements. The ICC and COR were comparable for the BT/PT and

  10. Summary of CCTF test results

    International Nuclear Information System (INIS)

    Iguchi, T.; Murao, Y.; Sugimoto, J.; Akimoto, H.; Okubo, T.; Hojo, T.

    1987-01-01

    Conservatism of current safety analysis was assessed by comparing the predicted result with cylindrical core test facility (CCTF) test result performed at Japan Atomic Energy Research Institute. WREM code was selected for the assessment. The overall conservatism of the WREM code on the peak clad temperature prediction was confirmed against CCTF evaluation model (EM) test which simulated the typical initial and boundary conditions in the safety evaluation analysis. WREM code predicted the reasonable core boundary conditions and the conservatism of the code came mainly from core calculation. The conservatism of the WREM code against CCTF data could be attributed to the following three points: (1) no horizontal mixing assumption between subchannels at each elevation; (2) no modeling on heat transfer enhancement caused by the radial core power profile; and (3) conservative heat transfer correlations in the code

  11. Mobile evaporator corrosion test results

    International Nuclear Information System (INIS)

    Rozeveld, A.; Chamberlain, D.B.

    1997-05-01

    Laboratory corrosion tests were conducted on eight candidates to select a durable and cost-effective alloy for use in mobile evaporators to process radioactive waste solutions. Based on an extensive literature survey of corrosion data, three stainless steel alloys (304L, 316L, AL-6XN), four nickel-based alloys (825, 625, 690, G-30), and titanium were selected for testing. The corrosion tests included vapor phase, liquid junction (interface), liquid immersion, and crevice corrosion tests on plain and welded samples of candidate materials. Tests were conducted at 80 degrees C for 45 days in two different test solutions: a nitric acid solution. to simulate evaporator conditions during the processing of the cesium ion-exchange eluant and a highly alkaline sodium hydroxide solution to simulate the composition of Tank 241-AW-101 during evaporation. All of the alloys exhibited excellent corrosion resistance in the alkaline test solution. Corrosion rates were very low and localized corrosion was not observed. Results from the nitric acid tests showed that only 316L stainless steel did not meet our performance criteria. The 316L welded interface and crevice specimens had rates of 22.2 mpy and 21.8 mpy, respectively, which exceeds the maximum corrosion rate of 20 mpy. The other welded samples had about the same corrosion resistance as the plain samples. None of the welded samples showed preferential weld or heat-affected zone (HAZ) attack. Vapor corrosion was negligible for all alloys. All of the alloys except 316L exhibited either open-quotes satisfactoryclose quotes (2-20 mpy) or open-quotes excellentclose quotes (<2 mpy) corrosion resistance as defined by National Association of Corrosion Engineers. However, many of the alloys experienced intergranular corrosion in the nitric acid test solution, which could indicate a susceptibility to stress corrosion cracking (SCC) in this environment

  12. Test-retest reliability of trunk accelerometric gait analysis

    DEFF Research Database (Denmark)

    Henriksen, Marius; Lund, Hans; Moe-Nilssen, R

    2004-01-01

    The purpose of this study was to determine the test-retest reliability of a trunk accelerometric gait analysis in healthy subjects. Accelerations were measured during walking using a triaxial accelerometer mounted on the lumbar spine of the subjects. Six men and 14 women (mean age 35.2; range 18...... a definite potential in clinical gait analysis....

  13. Test of Creative Imagination: Validity and Reliability Study

    Science.gov (United States)

    Gundogan, Aysun; Ari, Meziyet; Gonen, Mubeccel

    2013-01-01

    The purpose of this study was to investigate validity and reliability of the test of creative imagination. This study was conducted with the participation of 1000 children, aged between 9-14 and were studying in six primary schools in the city center of Denizli Province, chosen by cluster ratio sampling. In the study, it was revealed that the…

  14. New design algorithm and reliability testing of solar powered near ...

    African Journals Online (AJOL)

    New design algorithm and reliability testing of solar powered near-space flight vehicle for defense and security. ... To overcome this problem, we propose a pseudo-satellite system where telecommunication devices are carried on a perpetually flying solar aircraft cruising at stratospheric altitude. Our aircraft will combine ...

  15. Construct validity and reliability of automated body reaction test ...

    African Journals Online (AJOL)

    Automated Body Reaction Test (ABRT) is a new device for skills and physical assessment instrument to measure ability on react, move quickly and accurately in accordance with stimulus. A total of 474 subjects aged 7-17 years old were randomly selected for the construct validity (n=330) and reliability (n=144). The ABRT ...

  16. MEMS Reliability: Infrastructure, Test Structures, Experiments, and Failure Modes

    Energy Technology Data Exchange (ETDEWEB)

    TANNER,DANELLE M.; SMITH,NORMAN F.; IRWIN,LLOYD W.; EATON,WILLIAM P.; HELGESEN,KAREN SUE; CLEMENT,J. JOSEPH; MILLER,WILLIAM M.; MILLER,SAMUEL L.; DUGGER,MICHAEL T.; WALRAVEN,JEREMY A.; PETERSON,KENNETH A.

    2000-01-01

    The burgeoning new technology of Micro-Electro-Mechanical Systems (MEMS) shows great promise in the weapons arena. We can now conceive of micro-gyros, micro-surety systems, and micro-navigators that are extremely small and inexpensive. Do we want to use this new technology in critical applications such as nuclear weapons? This question drove us to understand the reliability and failure mechanisms of silicon surface-micromachined MEMS. Development of a testing infrastructure was a crucial step to perform reliability experiments on MEMS devices and will be reported here. In addition, reliability test structures have been designed and characterized. Many experiments were performed to investigate failure modes and specifically those in different environments (humidity, temperature, shock, vibration, and storage). A predictive reliability model for wear of rubbing surfaces in microengines was developed. The root causes of failure for operating and non-operating MEMS are discussed. The major failure mechanism for operating MEMS was wear of the polysilicon rubbing surfaces. Reliability design rules for future MEMS devices are established.

  17. Reliable and sensitive physical testing of elite trapeze sailors

    DEFF Research Database (Denmark)

    Bay, Jonathan; Bojsen-Møller, Jens; Nordsborg, Nikolai Baastrup

    2018-01-01

    It was investigated, if a newly developed discipline specific test for elite-level trapeze sailors is reli-able and sensitive. Furthermore, the physical demands of trapeze sailing were examined. In part 1, nine national team athletes were accustomed to a simulated sailing test, which subsequently....... 265 ± 45W, Psailing was 54.5 ± 7.2% VO2max , 75.1 ± 3.1% HRmax and 5.8 ± 2.7 mM, respectively. However, VO2 and HR were substantially higher for periods of the race...... as peak values were 83.5 ± 11.4% and 89.9 ± 1.7% of max, respectively. In conclusion, the present test is reliable and sensitive, thus providing a sailing specific alternative to traditional physical testing of elite trapeze sailors. Additionally, on-water rac-ing requires moderate aerobic energy...

  18. Gearbox Reliability Collaborative Phase 3 Gearbox 3 Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wallen, Robb [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-10-01

    This document describes the Phase 3 test plan for the Gearbox Reliability Collaborative Gearbox #3. The primary test objective is to measure the planetary load sharing characteristics in the same conditions as the original gearbox design. If the measured load-sharing characteristics are close to the design model, the projected three-times improvement in planetary section predicted fatigue life and the efficacy of preloaded tapered roller bearings in mitigating the planetary bearing fatigue failure mode will have been demonstrated.

  19. NDE reliability gains from combining eddy-current and ultrasonic testing

    International Nuclear Information System (INIS)

    Horn, D.; Mayo, W.R.

    1999-01-01

    We investigate statistical methods for combining the results of two complementary inspection techniques, eddy-current and ultrasonic testing. The reliability of rejection/acceptance decisions based on combined information is compared with that based on each inspection technique individually. The measured reliability increases with the amount of information incorporated in the decision. (author)

  20. Reliability and accuracy of Cooper's test in male long distance runners

    Directory of Open Access Journals (Sweden)

    J.R. Alvero-Cruz

    2017-06-01

    Conclusions: All together, our results may confirm a good accuracy and reliability of Cooper's test in amateur long distance runners. Also, improvements or impairment lower than 52.2 m must not be associated with exercise training or retraining, since they are below the values of intra-subject reliability.

  1. Reliability analysis of structures under periodic proof tests in service

    Science.gov (United States)

    Yang, J.-N.

    1976-01-01

    A reliability analysis of structures subjected to random service loads and periodic proof tests treats gust loads and maneuver loads as random processes. Crack initiation, crack propagation, and strength degradation are treated as the fatigue process. The time to fatigue crack initiation and ultimate strength are random variables. Residual strength decreases during crack propagation, so that failure rate increases with time. When a structure fails under periodic proof testing, a new structure is built and proof-tested. The probability of structural failure in service is derived from treatment of all the random variables, strength degradations, service loads, proof tests, and the renewal of failed structures. Some numerical examples are worked out.

  2. Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test Report

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan; Wallen, Robb

    2015-06-10

    Many gearboxes in wind turbines have not been achieving their expected design life [1]; they do, however, commonly meet or exceed the design criteria specified in current standards in the gear, bearing, and wind turbine industry as well as third-party certification criteria. The cost of gearbox replacements and rebuilds, as well as the downtime associated with these failures, has elevated the cost of wind energy. In 2006, the U.S. Department of Energy established the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC). Its key goal is to understand the root causes of premature gearbox failures and improve their reliability [2]. The GRC is examining a hypothesis that the gap between design-estimated and actual wind turbine gearbox reliability is caused by underestimation of loads, inaccurate design tools, the absence of critical elements in the design process, or insufficient testing. This test report describes the recent tests of GRC gearbox (GB) 2 in the National Wind Technology Center (NWTC) dynamometer and documents any modifications to the original test plan [3]. In this manner, it serves as a guide for interpreting the publicly released data sets with brief analyses to illustrate the data. Specific objectives of the test were to assess the effect of dynamic nontorque load (NTL) on the planetary section, generator misalignment on the highspeed shaft (HSS), and field representative conditions on the gearbox in general. Detailed analysis of those test objectives will be presented in subsequent publications.

  3. Reliability assessment for safety critical systems by statistical random testing

    International Nuclear Information System (INIS)

    Mills, S.E.

    1995-11-01

    In this report we present an overview of reliability assessment for software and focus on some basic aspects of assessing reliability for safety critical systems by statistical random testing. We also discuss possible deviations from some essential assumptions on which the general methodology is based. These deviations appear quite likely in practical applications. We present and discuss possible remedies and adjustments and then undertake applying this methodology to a portion of the SDS1 software. We also indicate shortcomings of the methodology and possible avenues to address to follow to address these problems. (author). 128 refs., 11 tabs., 31 figs

  4. Reliability assessment for safety critical systems by statistical random testing

    Energy Technology Data Exchange (ETDEWEB)

    Mills, S E [Carleton Univ., Ottawa, ON (Canada). Statistical Consulting Centre

    1995-11-01

    In this report we present an overview of reliability assessment for software and focus on some basic aspects of assessing reliability for safety critical systems by statistical random testing. We also discuss possible deviations from some essential assumptions on which the general methodology is based. These deviations appear quite likely in practical applications. We present and discuss possible remedies and adjustments and then undertake applying this methodology to a portion of the SDS1 software. We also indicate shortcomings of the methodology and possible avenues to address to follow to address these problems. (author). 128 refs., 11 tabs., 31 figs.

  5. A Test Stand for Ion Sources of Ultimate Reliability

    International Nuclear Information System (INIS)

    Enparantza, R.; Uriarte, L.; Romano, P.; Alonso, J.; Ariz, I.; Egiraun, M.; Bermejo, F. J.; Etxebarria, V.; Lucas, J.; Del Rio, J. M.; Letchford, A.; Faircloth, D.; Stockli, M.

    2009-01-01

    The rationale behind the ITUR project is to perform a comparison between different kinds of H - ion sources using the same beam diagnostics setup. In particular, a direct comparison will be made in terms of the emittance characteristics of Penning Type sources such as those currently in use in the injector for the ISIS (UK) Pulsed Neutron Source and those of volumetric type such as that driving the injector for the ORNL Spallation Neutron Source (TN, U.S.A.). The endeavour here pursued is thus to build an Ion Source Test Stand where virtually any type of source can be tested and its features measured and, thus compared to the results of other sources under the same gauge. It would be possible then to establish a common ground for effectively comparing different ion sources. The long term objectives are thus to contribute towards building compact sources of minimum emittance, maximum performance, high reliability-availability, high percentage of desired particle production, stability and high brightness. The project consortium is lead by Tekniker-IK4 research centre and partners are companies Elytt Energy and Jema Group. The technical viability is guaranteed by the collaboration between the project consortium and several scientific institutions, such the CSIC (Spain), the University of the Basque Country (Spain), ISIS (STFC-UK), SNS (ORNL-USA) and CEA in Saclay (France).

  6. Photovoltaic module reliability improvement through application testing and failure analysis

    Science.gov (United States)

    Dumas, L. N.; Shumka, A.

    1982-01-01

    During the first four years of the U.S. Department of Energy (DOE) National Photovoltatic Program, the Jet Propulsion Laboratory Low-Cost Solar Array (LSA) Project purchased about 400 kW of photovoltaic modules for test and experiments. In order to identify, report, and analyze test and operational problems with the Block Procurement modules, a problem/failure reporting and analysis system was implemented by the LSA Project with the main purpose of providing manufacturers with feedback from test and field experience needed for the improvement of product performance and reliability. A description of the more significant types of failures is presented, taking into account interconnects, cracked cells, dielectric breakdown, delamination, and corrosion. Current design practices and reliability evaluations are also discussed. The conducted evaluation indicates that current module designs incorporate damage-resistant and fault-tolerant features which address field failure mechanisms observed to date.

  7. The reliability of knee joint position testing using electrogoniometry

    Directory of Open Access Journals (Sweden)

    Winter Adele

    2008-01-01

    Full Text Available Abstract Background The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric® electrogoniometer. The clinical utility of electrogoniometry was also addressed. Methods The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers. Results In the first study, inter-tester reliability (ICC[2,10] ranged from 0.58–0.71 in supine, 0.68–0.79 in sitting and 0.57–0.80 in standing. The standard error of measurement between testers was less than 3.55° and the limits of agreement ranged from -12.51° to 12.21°. Reliability coefficients for intra-tester reliability (ICC[3,10] ranged from 0.75–0.76 in supine, 0.86–0.87 in sitting and 0.87–0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7° and the limits of agreement ranged from -8.13° to 7.90°. The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5°. Conclusion Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer.

  8. Evaluating the RELM Test Results

    Directory of Open Access Journals (Sweden)

    Michael K. Sachs

    2012-01-01

    Full Text Available We consider implications of the Regional Earthquake Likelihood Models (RELM test results with regard to earthquake forecasting. Prospective forecasts were solicited for M≥4.95 earthquakes in California during the period 2006–2010. During this period 31 earthquakes occurred in the test region with M≥4.95. We consider five forecasts that were submitted for the test. We compare the forecasts utilizing forecast verification methodology developed in the atmospheric sciences, specifically for tornadoes. We utilize a “skill score” based on the forecast scores λfi of occurrence of the test earthquakes. A perfect forecast would have λfi=1, and a random (no skill forecast would have λfi=2.86×10-3. The best forecasts (largest value of λfi for the 31 earthquakes had values of λfi=1.24×10-1 to λfi=5.49×10-3. The best mean forecast for all earthquakes was λ̅f=2.84×10-2. The best forecasts are about an order of magnitude better than random forecasts. We discuss the earthquakes, the forecasts, and alternative methods of evaluation of the performance of RELM forecasts. We also discuss the relative merits of alarm-based versus probability-based forecasts.

  9. EFTF cobalt test assembly results

    International Nuclear Information System (INIS)

    Rawlins, J.A.; Wootan, D.W.; Carter, L.L.; Brager, H.R.; Schenter, R.E.

    1988-01-01

    A cobalt test assembly containing yttrium hydride pins for neutron moderation was irradiated in the Fast Flux Test Facility during Cycle 9A for 137.7 equivalent full power days at a power level fo 291 MW. The 36 test pins consisted of a batch of 32 pins containing cobalt metal to produce Co-60, and a set of 4 pins with europium oxide to produce Gd-153, a radioisotope used in detection of the bone disease Osteoporosis. Post-irradiation examination of the cobalt pins determined the Co-60 produced with an accuracy of about 5 %. The measured Co-60 spatially distributed concentrations were within 20 % of the calculated concentrations. The assembly average Co-60 measured activity was 4 % less than the calculated value. The europium oxide pins were gamma scanned for the europium isotopes Eu-152 and Eu-154 to an absolute accuracy of about 10 %. The measured europium radioisotpe anc Gd-153 concentrations were within 20 % of calculated values. In conclusion, the hydride assembly performed well and is an excellent vehicle for many Fast Flux Test Facility isotope production applications. The results also demonstrate that the calculational methods developed by the Westinghouse Hanford Company are very accurate. (author)

  10. Technical report on the Piping Reliability Proving Tests at the Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    1993-05-01

    Japan Atomic Energy Research Institute (JAERI) conducts Piping Reliability Proving Tests from 1975 to 1992 based upon the contracts between JAERI and Science and Technology Agency of Japan (STA) under the auspices of the special account law for electric power development promotion. The purpose of these tests are to prove the structural reliability of the primary cooling piping constituting a part of the pressure boundary in the light water reactor power plants. The tests with large experimental facilities had ended already in 1990. Presently piping reliability analysis by the probabilistic fracture mechanics method is being done. Until now annual reports concerning the proving tests were produced and submitted to STA, whereas this report summarizes the test results done during these 16 years. Objectives of the piping reliability proving tests are to prove that the primary piping of the light water reactor (1) be reliable throughout the service period, (2) have no possibility of rupture, (3) bring no detrimental influence on the surrounding instrumentations or equipments near the break location even if it ruptured suddenly. To attain these objectives (i) pipe fatigue tests, (ii) unstable pipe fracture tests, (iii) pipe rupture tests and also the analyses by computer codes were done. After carrying out these tests, it is verified that the piping is reliable throughout the service period. The authors of this report are T. Isozaki, K. Shibata, S. Ueda, R. Kurihara, K. Onizawa and A. Kohsaka. The parts they wrote are shown in contents. (author)

  11. Test of understanding of vectors: A reliable multiple-choice vector concept test

    Science.gov (United States)

    Barniol, Pablo; Zavala, Genaro

    2014-06-01

    In this article we discuss the findings of our research on students' understanding of vector concepts in problems without physical context. First, we develop a complete taxonomy of the most frequent errors made by university students when learning vector concepts. This study is based on the results of several test administrations of open-ended problems in which a total of 2067 students participated. Using this taxonomy, we then designed a 20-item multiple-choice test [Test of understanding of vectors (TUV)] and administered it in English to 423 students who were completing the required sequence of introductory physics courses at a large private Mexican university. We evaluated the test's content validity, reliability, and discriminatory power. The results indicate that the TUV is a reliable assessment tool. We also conducted a detailed analysis of the students' understanding of the vector concepts evaluated in the test. The TUV is included in the Supplemental Material as a resource for other researchers studying vector learning, as well as instructors teaching the material.

  12. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Telomere Q-PNA-FISH--reliable results from stochastic signals.

    Directory of Open Access Journals (Sweden)

    Andrea Cukusic Kalajzic

    Full Text Available Structural and functional analysis of telomeres is very important for understanding basic biological functions such as genome stability, cell growth control, senescence and aging. Recently, serious concerns have been raised regarding the reliability of current telomere measurement methods such as Southern blot and quantitative polymerase chain reaction. Since telomere length is associated with age related pathologies, including cardiovascular disease and cancer, both at the individual and population level, accurate interpretation of measured results is a necessity. The telomere Q-PNA-FISH technique has been widely used in these studies as well as in commercial analysis for the general population. A hallmark of telomere Q-PNA-FISH is the wide variation among telomere signals which has a major impact on obtained results. In the present study we introduce a specific mathematical and statistical analysis of sister telomere signals during cell culture senescence which enabled us to identify high regularity in their variations. This phenomenon explains the reproducibility of results observed in numerous telomere studies when the Q-PNA-FISH technique is used. In addition, we discuss the molecular mechanisms which probably underlie the observed telomere behavior.

  14. First reliability test of a surface micromachined microengine using SHiMMeR

    Energy Technology Data Exchange (ETDEWEB)

    Tanner, D.M.; Smith, N.F.; Bowman, D.J. [and others

    1997-08-01

    The first-ever reliability stress test on surface micromachined microengines developed at Sandia National Laboratories (SNL) has been completed. We stressed 41 microengines at 36,000 RPM and inspected the functionality at 60 RPM. We have observed an infant mortality region, a region of low failure rate (useful life), and no signs of wearout in the data. The reliability data are presented and interpreted using standard reliability methods. Failure analysis results on the stressed microengines are presented. In our effort to study the reliability of MEMS, we need to observe the failures of large numbers of parts to determine the failure modes. To facilitate testing of large numbers of micromachines. The Sandia High Volume Measurement of Micromachine Reliability (SHiMMeR) system has computer controlled positioning and the capability to inspect moving parts. The development of this parallel testing system is discussed in detail.

  15. Test–re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females

    Directory of Open Access Journals (Sweden)

    Chris Beardsley

    2016-03-01

    Full Text Available Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test–re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81–0.88, test–re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88–0.95, and test–re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65 and good on the right side (ICC = 0.85. Conclusion. Inter-rater reliability and test–re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test–re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test–re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.

  16. Digital System Reliability Test for the Evaluation of safety Critical Software of Digital Reactor Protection System

    Directory of Open Access Journals (Sweden)

    Hyun-Kook Shin

    2006-08-01

    Full Text Available A new Digital Reactor Protection System (DRPS based on VME bus Single Board Computer has been developed by KOPEC to prevent software Common Mode Failure(CMF inside digital system. The new DRPS has been proved to be an effective digital safety system to prevent CMF by Defense-in-Depth and Diversity (DID&D analysis. However, for practical use in Nuclear Power Plants, the performance test and the reliability test are essential for the digital system qualification. In this study, a single channel of DRPS prototype has been manufactured for the evaluation of DRPS capabilities. The integrated functional tests are performed and the system reliability is analyzed and tested. The results of reliability test show that the application software of DRPS has a very high reliability compared with the analog reactor protection systems.

  17. RSG Deployment Case Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Owsley, Stanley L.; Dodson, Michael G.; Hatchell, Brian K.; Seim, Thomas A.; Alexander, David L.; Hawthorne, Woodrow T.

    2005-09-01

    The RSG deployment case design is centered on taking the RSG system and producing a transport case that houses the RSG in a safe and controlled manner for transport. The transport case was driven by two conflicting constraints, first that the case be as light as possible, and second that it meet a stringent list of Military Specified requirements. The design team worked to extract every bit of weight from the design while striving to meet the rigorous Mil-Spec constraints. In the end compromises were made primarily on the specification side to control the overall weight of the transport case. This report outlines the case testing results.

  18. Toward valid and reliable brain imaging results in eating disorders.

    Science.gov (United States)

    Frank, Guido K W; Favaro, Angela; Marsh, Rachel; Ehrlich, Stefan; Lawson, Elizabeth A

    2018-03-01

    Human brain imaging can help improve our understanding of mechanisms underlying brain function and how they drive behavior in health and disease. Such knowledge may eventually help us to devise better treatments for psychiatric disorders. However, the brain imaging literature in psychiatry and especially eating disorders has been inconsistent, and studies are often difficult to replicate. The extent or severity of extremes of eating and state of illness, which are often associated with differences in, for instance hormonal status, comorbidity, and medication use, commonly differ between studies and likely add to variation across study results. Those effects are in addition to the well-described problems arising from differences in task designs, data quality control procedures, image data preprocessing and analysis or statistical thresholds applied across studies. Which of those factors are most relevant to improve reproducibility is still a question for debate and further research. Here we propose guidelines for brain imaging research in eating disorders to acquire valid results that are more reliable and clinically useful. © 2018 Wiley Periodicals, Inc.

  19. Reliability of Maximal Strength Testing in Novice Weightlifters

    Science.gov (United States)

    Loehr, James A.; Lee, Stuart M. C.; Feiveson, Alan H.; Ploutz-Snyder, Lori L.

    2009-01-01

    The one repetition maximum (1RM) is a criterion measure of muscle strength. However, the reliability of 1RM testing in novice subjects has received little attention. Understanding this information is crucial to accurately interpret changes in muscle strength. To evaluate the test-retest reliability of a squat (SQ), heel raise (HR), and deadlift (DL) 1RM in novice subjects. Twenty healthy males (31 plus or minus 5 y, 179.1 plus or minus 6.1 cm, 81.4 plus or minus 10.6 kg) with no weight training experience in the previous six months participated in four 1RM testing sessions, with each session separated by 5-7 days. SQ and HR 1RM were conducted using a smith machine; DL 1RM was assessed using free weights. Session 1 was considered a familiarization and was not included in the statistical analyses. Repeated measures analysis of variance with Tukey fs post-hoc tests were used to detect between-session differences in 1RM (p.0.05). Test-retest reliability was evaluated by intraclass correlation coefficients (ICC). During Session 2, the SQ and DL 1RM (SQ: 90.2 }4.3, DL: 75.9 }3.3 kg) were less than Session 3 (SQ: 95.3 }4.1, DL: 81.5 plus or minus 3.5 kg) and Session 4 (SQ: 96.6 }4.0, DL: 82.4 }3.9 kg), but there were no differences between Session 3 and Session 4. HR 1RM measured during Session 2 (150.1 }3.7 kg) and Session 3 (152.5 }3.9 kg) were not different from one another, but both were less than Session 4 (157.5 }3.8 kg). The reliability (ICC) of 1RM measures for Sessions 2-4 were 0.88, 0.83, and 0.87, for SQ, HR, and DL, respectively. When considering only Sessions 3 and 4, the reliability was 0.93, 0.91, and 0.86 for SQ, HR, and DL, respectively. One familiarization session and 2 test sessions (for SQ and DL) were required to obtain excellent reliability (ICC greater than or equal to 0.90) in 1RM values with novice subjects. We were unable to attain this level of reliability following 3 HR testing sessions therefore additional sessions may be required to obtain an

  20. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  1. Reliability of physical examination tests for the diagnosis of knee disorders: Evidence from a systematic review.

    Science.gov (United States)

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Desmeules, François

    2016-12-01

    Clinicians often rely on physical examination tests to guide them in the diagnostic process of knee disorders. However, reliability of these tests is often overlooked and may influence the consistency of results and overall diagnostic validity. Therefore, the objective of this study was to systematically review evidence on the reliability of physical examination tests for the diagnosis of knee disorders. A structured literature search was conducted in databases up to January 2016. Included studies needed to report reliability measures of at least one physical test for any knee disorder. Methodological quality was evaluated using the QAREL checklist. A qualitative synthesis of the evidence was performed. Thirty-three studies were included with a mean QAREL score of 5.5 ± 0.5. Based on low to moderate quality evidence, the Thessaly test for meniscal injuries reached moderate inter-rater reliability (k = 0.54). Based on moderate to excellent quality evidence, the Lachman for anterior cruciate ligament injuries reached moderate to excellent inter-rater reliability (k = 0.42 to 0.81). Based on low to moderate quality evidence, the Tibiofemoral Crepitus, Joint Line and Patellofemoral Pain/Tenderness, Bony Enlargement and Joint Pain on Movement tests for knee osteoarthritis reached fair to excellent inter-rater reliability (k = 0.29 to 0.93). Based on low to moderate quality evidence, the Lateral Glide, Lateral Tilt, Lateral Pull and Quality of Movement tests for patellofemoral pain reached moderate to good inter-rater reliability (k = 0.49 to 0.73). Many physical tests appear to reach good inter-rater reliability, but this is based on low-quality and conflicting evidence. High-quality research is required to evaluate the reliability of knee physical examination tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. The reliability of sickling and solubility tests and peripheral blood ...

    African Journals Online (AJOL)

    The reliability of sickling and solubility tests and peripheral blood film method for sickle cell disease screening at district health centers in Uganda. ... Les 200 prélèvements des enfants ages de 6 mois à 5 ans ont été analysés de façon indépendante en utilisant la méthode des analyses d'hématies falciformes, la solubilité et ...

  3. Reliability, Validity and Factor Structure of Drug Abuse Screening Test

    OpenAIRE

    Sayed Hadi Sayed Alitabar; Mojtaba Habibi; Maryam Falahatpisheh; Musa Arvin

    2016-01-01

    Background and Objective: According to the increasing of substance use in the country, more researches about this phenomenon are necessary. This Study Investigates the Validity, Reliability and Confirmatory Factor Structure of the Drug Abuse Screening test (DAST). Materials and Methods: The Sample Consisted of 381 Patients (143 Women and 238 Men) with a Multi-Stage Cluster Sampling of Areas 2, 6 and 12 of Tehran Were Selected from Each Region, 6 Randomly Selected Drug Rehabilitation Center. T...

  4. Assessing high reliability via Bayesian approach and accelerated tests

    International Nuclear Information System (INIS)

    Erto, Pasquale; Giorgio, Massimiliano

    2002-01-01

    Sometimes the assessment of very high reliability levels is difficult for the following main reasons: - the high reliability level of each item makes it impossible to obtain, in a reasonably short time, a sufficient number of failures; - the high cost of the high reliability items to submit to life tests makes it unfeasible to collect enough data for 'classical' statistical analyses. In the above context, this paper presents a Bayesian solution to the problem of estimation of the parameters of the Weibull-inverse power law model, on the basis of a limited number (say six) of life tests, carried out at different stress levels, all higher than the normal one. The over-stressed (i.e. accelerated) tests allow the use of experimental data obtained in a reasonably short time. The Bayesian approach enables one to reduce the required number of failures adding to the failure information the available a priori engineers' knowledge. This engineers' involvement conforms to the most advanced management policy that aims at involving everyone's commitment in order to obtain total quality. A Monte Carlo study of the non-asymptotic properties of the proposed estimators and a comparison with the properties of maximum likelihood estimators closes the work

  5. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    Science.gov (United States)

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing

  6. Diagnostic reliability of MMPI-2 computer-based test interpretations.

    Science.gov (United States)

    Pant, Hina; McCabe, Brian J; Deskovitz, Mark A; Weed, Nathan C; Williams, John E

    2014-09-01

    Reflecting the common use of the MMPI-2 to provide diagnostic considerations, computer-based test interpretations (CBTIs) also typically offer diagnostic suggestions. However, these diagnostic suggestions can sometimes be shown to vary widely across different CBTI programs even for identical MMPI-2 profiles. The present study evaluated the diagnostic reliability of 6 commercially available CBTIs using a 20-item Q-sort task developed for this study. Four raters each sorted diagnostic classifications based on these 6 CBTI reports for 20 MMPI-2 profiles. Two questions were addressed. First, do users of CBTIs understand the diagnostic information contained within the reports similarly? Overall, diagnostic sorts of the CBTIs showed moderate inter-interpreter diagnostic reliability (mean r = .56), with sorts for the 1/2/3 profile showing the highest inter-interpreter diagnostic reliability (mean r = .67). Second, do different CBTIs programs vary with respect to diagnostic suggestions? It was found that diagnostic sorts of the CBTIs had a mean inter-CBTI diagnostic reliability of r = .56, indicating moderate but not strong agreement across CBTIs in terms of diagnostic suggestions. The strongest inter-CBTI diagnostic agreement was found for sorts of the 1/2/3 profile CBTIs (mean r = .71). Limitations and future directions are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  7. Assessing Reliability of Two Versions of Vocabulary Levels Tests in Iranian Context

    Directory of Open Access Journals (Sweden)

    Aso Bayazidi

    2017-02-01

    Full Text Available This study examined the equivalence and reliability of the two versions of the Vocabulary Levels Test in an Iranian context. This study was motivated by the fact that the Vocabulary Levels test is increasingly being used in Iran for both research and pedagogical purposes without having been checked for validity and reliability in this context. The equivalence and reliability of the two versions of the test were examined through the parallel-form approach to reliability in Classical True Score theory. Seventy-five intermediate learners of English as a foreign language at the Iran Language Institute took the two versions of the test with one week interval between the two administrations in a counterbalanced fashion. To examine the equivalence of the two versions, the means and variances of the scores obtained for the two tests were compared using paired-sample t-test and one-way ANOVA, respectively. The results of the analyses indicated that the difference between the means of the two versions was significant, and the two versions cannot be considered as parallel forms. To assess the reliability of the two versions, the correlation between the scores obtained from them was estimated using Pearson Product Moment correlation. The results of the analyses showed that the two versions are highly correlated and are reliable tests. It is concluded that the two versions should not be treated as equivalent in longitudinal and gain score studies.

  8. Test-retest reliability of the Danish Adult Reading Test in patients with comorbid psychosis and cannabis-use disorder

    DEFF Research Database (Denmark)

    Hjorthøj, Carsten Rygaard; Vesterager, Lone; Nordentoft, Merete

    2013-01-01

    Background: The New Adult Reading Test is a common instrument for assessing pre-morbid IQ for patients with, for instance, schizophrenia. However, test-retest reliability has not been established for patients dually diagnosed with psychosis and substance use disorder. Furthermore, test......-retest reliability of the Danish adaptation has never been established in any population. Aims: To determine the test-retest reliability of the Danish Adult Reading Test (DART) (adapted from the National Adult Reading Test, NART) for patients dually diagnosed with psychosis and cannabis-use disorder. Methods......: This was a secondary analysis of the CapOpus randomized trial. As part of the trial, 103 patients were randomized, and completed the DART up to three times. Pearson's r and pairwise t-tests were calculated. Results: DART score was independent of randomization, cannabis-use frequency and psychopathology. Scores...

  9. NDT Reliability - Final Report. Reliability in non-destructive testing (NDT) of the canister components

    Energy Technology Data Exchange (ETDEWEB)

    Pavlovic, Mato; Takahashi, Kazunori; Mueller, Christina; Boehm, Rainer (BAM, Federal Inst. for Materials Research and Testing, Berlin (Germany)); Ronneteg, Ulf (Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden))

    2008-12-15

    This report describes the methodology of the reliability investigation performed on the ultrasonic phased array NDT system, developed by SKB in collaboration with Posiva, for inspection of the canisters for permanent storage of nuclear spent fuel. The canister is composed of a cast iron insert surrounded by a copper shell. The shell is composed of the tube and the lid/base which are welded to the tube after the fuel has been place, in the tube. The manufacturing process of the canister parts and the welding process are described. Possible defects, which might arise in the canister components during the manufacturing or in the weld during the welding, are identified. The number of real defects in manufactured components have been limited. Therefore the reliability of the NDT system has been determined using a number of test objects with artificial defects. The reliability analysis is based on the signal response analysis. The conventional signal response analysis is adopted and further developed before applied on the modern ultrasonic phased-array NDT system. The concept of multi-parameter a, where the response of the NDT system is dependent on more than just one parameter, is introduced. The weakness of use of the peak signal response in the analysis is demonstrated and integration of the amplitudes in the C-scan is proposed as an alternative. The calculation of the volume POD, when the part is inspected with more configurations, is also presented. The reliability analysis is supported by the ultrasonic simulation based on the point source synthesis method

  10. Gearbox Reliability Collaborative Phase 3 Gearbox 3 Test Report

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wallen, Robb [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-02-24

    Many gearboxes in wind turbines do not achieve their expected design life; they do, however, commonly meet or exceed the design criteria specified in current standards in the gear, bearing, and wind turbine industry as well as third-party certification criteria. The cost of gearbox replacements and rebuilds, as well as the downtime associated with these failures, increases the cost of wind energy. In 2007, the U.S. Department of Energy established the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC). Its goals are to understand the root causes of premature gearbox failures and to improve their reliability. The GRC is examining a hypothesis that the gap between design-estimated and actual wind turbine gearbox reliability is caused by underestimation of loads, inaccurate design tools, the absence of critical elements in the design process, or insufficient testing. This report describes the recently completed tests of GRC Gearbox 3 in the National Wind Technology Center dynamometer and documents any modifications to the original test plan. In this manner, it serves as a guide for interpreting the publicly released data sets with brief analyses to illustrate the data. The primary test objective was to measure the planetary load-sharing characteristics in the same conditions as the original GRC gearbox design. If the measured load-sharing characteristics are close to the design model, the projected improvement in planetary section fatigue life and the efficacy of preloaded TRBs in mitigating the planetary bearing fatigue failure mode will have been demonstrated. Detailed analysis of that test objective will be presented in subsequent publications.

  11. Inter-rater and intra-rater reliability of a movement control test in shoulder.

    Science.gov (United States)

    Rajasekar, S; Bangera, Rakshith K; Sekaran, Padmanaban

    2017-07-01

    Movement faults are commonly observed in patients with musculoskeletal pain. The Kinetic Medial Rotation Test (KMRT) is a movement control test used to identify movement faults of the scapula and gleno-humeral joints during arm movement. Objective tests such as the KMRT need to be reliable and valid for the results to be applied across different clinical settings and patient populations. The primary objective of the present study was to determine the intra-rater and inter-rater reliability of KMRT in subjects with and without shoulder pain. Sixty subjects were included in this study based on specific inclusion and exclusion criteria. Two musculoskeletal physiotherapists with different levels of clinical experience performed the tests. The intra-rater reliability was tested in twenty asymptomatic subjects by a single assessor at two week intervals. An equal number of subjects with and without shoulder pain were tested by both the assessors to determine the inter-rater reliability. Both components of the KMRT, the Gleno- Humeral Anterior Translation (GHAT) and the Scapular Forward Tilt (SCFT) were tested. The Kappa values for inter-rater reliability of the GHAT and SCFT were K = 0.68 & K = 0.65 respectively in subjects with shoulder pain. In asymptomatic subjects, the inter-rater reliability of GHAT was K = 0.61 and SCFT was K = 0.85. Intra-rater reliability ranged from K = 0.66 for GHAT to K = 0.87 for SCFT. Our study found substantial agreement in inter-rater reliability of KMRT in subjects with shoulder pain, whereas substantial to near perfect agreement was found in intra-rater and inter-rater reliability of KMRT in subjects without shoulder pain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Standardization, Validity and Reliability Study of Gülhane Aphasia Test-2 (GAT-2

    Directory of Open Access Journals (Sweden)

    İlknur Maviş

    2007-04-01

    Full Text Available OBJECTIVE: Gülhane Aphasia Test-2 (GAT-2 has been developed to show the presence of a language disorder ‘aphasia’ and to give the clinician implications for the accompanying speech disorders such as apraxia and dysarthria. OBJECTIVE: The aim of the study was to report standardization, validity and reliability study of GAT-2. METHODS: : 10 healthy individuals were tested initially for the pilot study. 134 healthy individual was included to the standardization study and 30 individuals with aphasia and 11 individuals with right brain injury was included to the validation study. The inter group GAT-2 score differentiations and the effects of age, years of education, sex variances were observed. GAT-2 cut-off scores were calculated by the scores of healthy individuals. GAT-2 test-retest reliability and inter-observer reliability was calculated. RESULTS: Healthy individuals’ GAT-2 scores were significantly different from the GAT-2 scores of aphasic patients, but not from right brain injured patients’. Healthy individuals’ GAT-2 scores were not affected from the sex, age variances but from years of education, so cut-off scores were calculated by this variance. GAT-2 scores of aphasic patients were not affected from age, sex and years of education. Test-retest and inter-observer reliability and internal consistency results showed that GAT-2 is a highly reliable aphasia screening test. CONCLUSION: GAT-2 was found to be a standardized, highly reliable and a valid aphasia test for Turkish stroke patients with aphasia

  13. Results of interlaboratory tests regarding TXRF

    International Nuclear Information System (INIS)

    Klockenkaemper, R.; Bohlen, A. von

    2000-01-01

    Interlaboratory or intercomparison tests can be performed for proficiency testing of individual laboratories, for the certification of a special sample material and for the validation of a certain method. We participated in two interlaboratory tests in order to validate total reflection x-ray fluorescence analysis (TXRF). We used our results to evaluate TXRF and to compare it with other competing methods, particularly with respect of precision and accuracy. The first interlaboratory test was organized by IAEA (International Atomic Energy Agency, Vienna, Austria). As a candidate for reference material, a lichen (IAEA-336 Lichen) was distributed among 27 participants. In our laboratory, the powdered biogenic material was digested with nitric acid under high pressure and analyzed by TXRF. - The second interlaboratory test was organized by IRMM (Institute for Reference Materials and Measurements, Geel, Belgium). As a certified test sample with undisclosed values, a sediment (IMEP-14) was delivered to 220 laboratories. We digested the geogenic material again by nitric acid and additionally by hydrofluoric acid and analyzed it by TXRF. - In both test samples, six or eight different trace elements, respectively, were determined by TXRF with a content between 2 and 2000 mg/kg. Calibration was carried out by internal standardization. For that purpose, Ga or Se, respectively, was added as standard element. The measurement uncertainty of TXRF was estimated by the method of error propagation. In our paper we will report on the results of the two interlaboratory tests. It will be shown that TXRF is highly reliable for a correct determination of trace elements in biogenic and geogenic samples. It is competitive with the established methods of trace analyses which were involved in these tests and it is even superior to them in certain aspects. (author)

  14. Test Results for CSTR Test 4

    International Nuclear Information System (INIS)

    Lee, D.D.

    2001-01-01

    One of the 3 technologies currently being developed for the Savannah River Salt Waste Processing Program is the Small-Tank Tetraphenylborate Process (STTP). This process uses sodium tetraphenylborate to precipitate and remove radioactive Cs from the waste and monosodium titanate to sorb and remove radioactive Sr and actinides. ORNL is demonstrating this process at the 1:4000 scale using a 20-liter continuous-flow stirred tank reactor (CSTR) system. The primary goal of Test 4 was to verify that the STTP process could achieve and maintain the necessary Cs decontamination while TPB was actively decomposing. Even with TPB being decomposed by the off-normal conditions of this test, the decontaimination factor for 137 Cs obtained for the filtrate from the Slurry Concentrating Tank ranged from 47,000 to 646,000, exceeding the WAC standard

  15. Development and reliability testing of a food store observation form.

    Science.gov (United States)

    Rimkus, Leah; Powell, Lisa M; Zenk, Shannon N; Han, Euna; Ohri-Vachaspati, Punam; Pugach, Oksana; Barker, Dianne C; Resnick, Elissa A; Quinn, Christopher M; Myllyluoma, Jaana; Chaloupka, Frank J

    2013-01-01

    To develop a reliable food store observational data collection instrument to be used for measuring product availability, pricing, and promotion. Observational data collection. A total of 120 food stores (26 supermarkets, 34 grocery stores, 54 gas/convenience stores, and 6 mass merchandise stores) in the Chicago metropolitan statistical area. Inter-rater reliability for product availability, pricing, and promotion measures on a food store observational data collection instrument. Cohen's kappa coefficient and proportion of overall agreement for dichotomous variables and intra-class correlation coefficient for continuous variables. Inter-rater reliability, as measured by average kappa coefficient, was 0.84 for food and beverage product availability measures, 0.80 for interior store characteristics, and 0.70 for exterior store characteristics. For continuous measures, average intra-class correlation coefficient was 0.82 for product pricing measures; 0.90 for counts of fresh, frozen, and canned fruit and vegetable options; and 0.85 for counts of advertisements on the store exterior and property. The vast majority of measures demonstrated substantial or almost perfect agreement. Although some items may require revision, results suggest that the instrument may be used to reliably measure the food store environment. Copyright © 2013 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  16. Maximal cardiorespiratory fitness testing in individuals with chronic stroke with cognitive impairment: practice test effects and test-retest reliability.

    Science.gov (United States)

    Olivier, Charles; Doré, Jean; Blanchet, Sophie; Brooks, Dina; Richards, Carol L; Martel, Guy; Robitaille, Nancy-Michelle; Maltais, Désirée B

    2013-11-01

    To evaluate, for individuals with chronic stroke with cognitive impairment, (1) the effects of a practice test on peak cardiorespiratory fitness test results; (2) cardiorespiratory fitness test-retest reliability; and (3) the relationship between individual practice test effects and cognitive impairment. Cross-sectional. Rehabilitation center. A convenience sample of 21 persons (men [n=12] and women [n=9]; age range, 48-81y; 44.9±36.2mo poststroke) with cognitive impairments who had sufficient lower limb function to perform the test. Not applicable. Peak oxygen consumption (Vo(2)peak, ml·kg(-1)·min(-1)). Test-retest reliability of Vo(2)peak was excellent (intraclass correlation coefficient model 2,1 [ICC2,1]=.94; 95% confidence interval [CI], .86-.98). A paired t test showed that there was no significant difference for the group for Vo(2)peak obtained from 2 symptom-limited cardiorespiratory fitness tests performed 1 week apart on a semirecumbent cycle ergometer (test 2-test 1 difference, -.32ml·kg(-1)·min(-1); 95% CI, -.69 to 1.33ml·kg(-1)·min(-1); P=.512). Individual test-retest differences in Vo(2)peak were, however, positively related to general cognitive function as measured by the Mini-Mental State Examination (ρ=.485; Preliably measured in this group without a practice test. General cognitive function, however, may influence the effect of a practice test in that those with lower general cognitive function appear to respond differently to a practice test than those with higher cognitive function. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  17. Accounting for Proof Test Data in a Reliability Based Design Optimization Framework

    Science.gov (United States)

    Ventor, Gerharad; Scotti, Stephen J.

    2012-01-01

    This paper investigates the use of proof (or acceptance) test data during the reliability based design optimization of structural components. It is assumed that every component will be proof tested and that the component will only enter into service if it passes the proof test. The goal is to reduce the component weight, while maintaining high reliability, by exploiting the proof test results during the design process. The proposed procedure results in the simultaneous design of the structural component and the proof test itself and provides the designer with direct control over the probability of failing the proof test. The procedure is illustrated using two analytical example problems and the results indicate that significant weight savings are possible when exploiting the proof test results during the design process.

  18. FIRST RESULTS FROM OEDOTENSIOMETRIC TESTS

    Directory of Open Access Journals (Sweden)

    Luigi Cavazza

    2008-09-01

    Full Text Available An oedotensiometer was used to examine to examine the behaviour of sieved sample of a swelling soil (a vertisol as well as of the same soils treated with solution of Na+ + Ca2+ to simulate the soil changes from excessive irrigation with brackish water. The oedometer test consisted in an infiltration of water from below through a ceramic porous plate at a feeding pressure of +10 cm water and successive drainage under a depression mostly of -112 cm of water. The rate of water entry as well as the swelling rate of the sample were monitored. Preliminary considerations regards the domains in which the shrinkage curve of a swelling soil is subdivided and make hypothesis on the swelling process expected when the infiltration from below of the sample is applied. The results support the hypothesis that when the water pressure is applied some water enters rather rapidly in the larger structural pores and is followed later by the swelling in the smaller pores, responsible for the basic domain. This first conclusion demonstrates that the assumption of a simultaneous movement of solid and liquid components in the sample, which is the base of most theoretical developments for swelling soils, cannot be accepted for the tested samples. Some cases with water clogging on the sample surface confirm a late final swelling of the soil and permitted to evaluate the hydraulic conductivity of the swollen soil. These manifestations are more evident in sodicated soils. The loading of the sample reduces the swelling of the sample and seems to reduce its permeability. The reduction of the feeding water pressure further reduces the sample swelling. The draining process from saturated soil sample shows that most of the process occurs in the large pores of the structural domain. This gives the possibility to evaluate the water diffusivity coefficient for the structural domain of the sample. In draining the soil with the highest sodication there was a variation of soil volume

  19. Reliability of isometric subtalar pronator and supinator strength testing.

    Science.gov (United States)

    Hagen, Marco; Lahner, Matthias; Winhuysen, Martin; Maiwald, Christian

    2015-01-01

    Due to the specific anatomy of the subtalar joint with its oblique axis, isometric pronator and supinator strength is not well documented. The purpose of this study was to determine intra- and between-session reliability of pronator and supinator strength and lower leg muscle activity measurements during maximum voluntary isometric contractions (MVIC). Pronator and supinator peak torques (PT), with and without supplementary visual muscle strength biofeedback (FB), and muscular activities of peroneus longus (PL) and tibialis anterior (TA) were assessed twice 3 days apart by the same examiner in 21 healthy young male adults (mean age: 27.6 years; SD = 3.9). Limits of agreement (LoA) and minimum detectable change (MDC) were evaluated. By applying FB, reliability of both pronator and supinator PT was improved: LoA were reduced from 32% to 26% and from 20% to 18% and MDC from 20% to 15% and from 16% to 12% in supinator and pronator PT, respectively. Learning effects in pronator and supinator PT (p isometric subtalar pronator and supinator strength testing is reliable in healthy subjects. LoA of 18% and 26% have to be exceeded for pronator and supinator PT, respectively, to detect relevant effects in repeated measures.

  20. Forward lunge as a functional performance test in ACL deficient subjects: test-retest reliability

    DEFF Research Database (Denmark)

    Alkjaer, Tine; Henriksen, Marius; Dyhre-Poulsen, Poul

    2009-01-01

    The forward lunge movement may be used as a functional performance test of anterior cruciate ligament (ACL) deficient and reconstructed subjects. The purposes were 1) to determine the test-retest reliability of a forward lunge in healthy subjects and 2) to determine the required numbers...... of repetitions necessary to yield satisfactory reliability. Nineteen healthy subjects performed four trials of a forward lunge on two different days. The movement time, impulses of the ground reaction forces (IFz, IFy), knee joint kinematics and dynamics during the forward lunge were calculated. The relative...... reliability was determined by calculation of Intraclass Correlation Coefficients (ICC). The IFz, IFy and the positive work of the knee extensors showed excellent reliability (ICC >0.75). All other variables demonstrated acceptable reliability (0.4>ICCreliability increased when more than...

  1. Test rig overview for validation and reliability testing of shutdown system software

    International Nuclear Information System (INIS)

    Zhao, M.; McDonald, A.; Dick, P.

    2007-01-01

    The test rig for Validation and Reliability Testing of shutdown system software has been upgraded from the AECL Windows-based test rig previously used for CANDU6 stations. It includes a Virtual Trip Computer, which is a software simulation of the functional specification of the trip computer, and a real-time trip computer simulator in a separate chassis, which is used during the preparation of trip computer test cases before the actual trip computers are available. This allows preparation work for Validation and Reliability Testing to be performed in advance of delivery of actual trip computers to maintain a project schedule. (author)

  2. INTERSESSION RELIABILITY OF UPPER EXTREMITY ISOKINETIC PUSH-PULL TESTING.

    Science.gov (United States)

    Riemann, Bryan L; Davis, Sarah E; Huet, Kevin; Davies, George J

    2016-02-01

    Based on the frequency pushing and pulling patterns are used in functional activities, there is a need to establish an objective method of quantifying the muscle performance characteristics associated with these motions, particularly during the later stages of rehabilitation as criteria for discharge. While isokinetic assessment offers an approach to quantifying muscle performance, little is known about closed kinetic chain (CKC) isokinetic testing of the upper extremity (UE). To determine the intersession reliability of isokinetic upper extremity measurement of pushing and pulling peak force and average power at slow (0.24 m/s), medium (0.43 m/s) and fast (0.61 m/s) velocities in healthy young adults. The secondary purpose was to compare pushing and pulling peak force (PF) and average power (AP) between the upper extremity limbs (dominant, non-dominant) across the three velocities. Twenty-four physically active men and women completed a test-retest (>96 hours) protocol in order to establish isokinetic UE CKC reliability of PF and AP during five maximal push and pull repetitions at three velocities. Both limb and speed orders were randomized between subjects. High test-retest relative reliability using intraclass correlation coefficients (ICC2, 1) were revealed for PF (.91-.97) and AP (.85-.95) across velocities, limbs and directions. PF typical error (% coefficient of variation) ranged from 6.1% to 11.3% while AP ranged from 9.9% to 26.7%. PF decreased significantly (p pushing were significantly greater than pulling at all velocities, however the push-pull differences in PF became less as velocity increased. There were no significant differences identified between the dominant and nondominant limbs. Isokinetically derived UE CKC push-pull PF and AP are reliable measures. The lack of limb differences in healthy normal participants suggests that clinicians can consider bilateral comparisons when interpreting test performance. The increase in pushing PF and

  3. Equipment design for reliability testing of protection system

    International Nuclear Information System (INIS)

    Situmorang, Johnny; Tjahjono, H.; Santosa, A. Z.; Tjahjani, S.DT.; Ismu, P.H; Haryanto, D.; Mulyanto, D.; Kusmono, S

    1999-01-01

    The equipment for reliability testing of cable of protection system has been designed as a a furnace with the electric heater have a 4 kW power, and need time 10 minute to reach the designed maximum temperature 3000C. The dimension of furnace is 800 mm diameter and 2000 mm length is isolated use rockwool isolator and coated by aluminium. For the designed maximum temperature the surface temperature is 78 0c. Assemble of specimens is arranged horizontally in the furnace. The failure criteria will be defined based on the behaviour of the load circuit in each line of cable specimens

  4. Irradiation effects test series test IE-1 test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.; Mehner, A.S.

    1977-03-01

    The report describes the results of the first programmatic test in the Nuclear Regulatory Commission Irradiation Effects Test Series. This test (IE-1) used four 0.97m long PWR-type fuel rods fabricated from previously irradiated Saxton fuel. The objectives of this test were to evaluate the effect of fuel pellet density on pellet-cladding interaction during a power ramp and to evaluate the influence of the irradiated state of the fuel and cladding on rod behavior during film boiling operation. Data are presented on the behavior of irradiated fuel rods during steady-state operation, a power ramp, and film boiling operation. The effects of as-fabricated gap size, as-fabricated fuel density, rod power, and power ramp rate on pellet-cladding interaction are discussed. Test data are compared with FRAP-T2 computer model predictions, and comments on the consequences of sustained film boiling operation on irradiated fuel rod behavior are provided

  5. Reliability and validity of a talent identification test battery for seated and standing Paralympic throws.

    Science.gov (United States)

    Spathis, Jemima Grace; Connick, Mark James; Beckman, Emma Maree; Newcombe, Peter Anthony; Tweedy, Sean Michael

    2015-01-01

    Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test-retest reliability. Talent identification test-retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland-Altman plots (Limits of Agreement). Spearman's correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.

  6. Basic Concepts in Classical Test Theory: Tests Aren't Reliable, the Nature of Alpha, and Reliability Generalization as a Meta-analytic Method.

    Science.gov (United States)

    Helms, LuAnn Sherbeck

    This paper discusses the fact that reliability is about scores and not tests and how reliability limits effect sizes. The paper also explores the classical reliability coefficients of stability, equivalence, and internal consistency. Stability is concerned with how stable test scores will be over time, while equivalence addresses the relationship…

  7. Content validity and reliability of test of gross motor development in Chilean children

    Directory of Open Access Journals (Sweden)

    Marcelo Cano-Cappellacci

    2015-01-01

    Full Text Available ABSTRACT OBJECTIVE To validate a Spanish version of the Test of Gross Motor Development (TGMD-2 for the Chilean population. METHODS Descriptive, transversal, non-experimental validity and reliability study. Four translators, three experts and 92 Chilean children, from five to 10 years, students from a primary school in Santiago, Chile, have participated. The Committee of Experts has carried out translation, back-translation and revision processes to determine the translinguistic equivalence and content validity of the test, using the content validity index in 2013. In addition, a pilot implementation was achieved to determine test reliability in Spanish, by using the intraclass correlation coefficient and Bland-Altman method. We evaluated whether the results presented significant differences by replacing the bat with a racket, using T-test. RESULTS We obtained a content validity index higher than 0.80 for language clarity and relevance of the TGMD-2 for children. There were significant differences in the object control subtest when comparing the results with bat and racket. The intraclass correlation coefficient for reliability inter-rater, intra-rater and test-retest reliability was greater than 0.80 in all cases. CONCLUSIONS The TGMD-2 has appropriate content validity to be applied in the Chilean population. The reliability of this test is within the appropriate parameters and its use could be recommended in this population after the establishment of normative data, setting a further precedent for the validation in other Latin American countries.

  8. Results of the event sequence reliability benchmark exercise

    International Nuclear Information System (INIS)

    Silvestri, E.

    1990-01-01

    The Event Sequence Reliability Benchmark Exercise is the fourth of a series of benchmark exercises on reliability and risk assessment, with specific reference to nuclear power plant applications, and is the logical continuation of the previous benchmark exercises on System Analysis Common Cause Failure and Human Factors. The reference plant is the Nuclear Power Plant at Grohnde Federal Republic of Germany a 1300 MW PWR plant of KWU design. The specific objective of the Exercise is to model, to quantify and to analyze such event sequences initiated by the occurrence of a loss of offsite power that involve the steam generator feed. The general aim is to develop a segment of a risk assessment, which ought to include all the specific aspects and models of quantification, such as common canal failure, Human Factors and System Analysis, developed in the previous reliability benchmark exercises, with the addition of the specific topics of dependences between homologous components belonging to different systems featuring in a given event sequence and of uncertainty quantification, to end up with an overall assessment of: - the state of the art in risk assessment and the relative influences of quantification problems in a general risk assessment framework. The Exercise has been carried out in two phases, both requiring modelling and quantification, with the second phase adopting more restrictive rules and fixing certain common data, as emerged necessary from the first phase. Fourteen teams have participated in the Exercise mostly from EEC countries, with one from Sweden and one from the USA. (author)

  9. Test-retest and between-site reliability in a multicenter fMRI study.

    Science.gov (United States)

    Friedman, Lee; Stern, Hal; Brown, Gregory G; Mathalon, Daniel H; Turner, Jessica; Glover, Gary H; Gollub, Randy L; Lauriello, John; Lim, Kelvin O; Cannon, Tyrone; Greve, Douglas N; Bockholt, Henry Jeremy; Belger, Aysenil; Mueller, Bryon; Doty, Michael J; He, Jianchun; Wells, William; Smyth, Padhraic; Pieper, Steve; Kim, Seyoung; Kubicki, Marek; Vangel, Mark; Potkin, Steven G

    2008-08-01

    In the present report, estimates of test-retest and between-site reliability of fMRI assessments were produced in the context of a multicenter fMRI reliability study (FBIRN Phase 1, www.nbirn.net). Five subjects were scanned on 10 MRI scanners on two occasions. The fMRI task was a simple block design sensorimotor task. The impulse response functions to the stimulation block were derived using an FIR-deconvolution analysis with FMRISTAT. Six functionally-derived ROIs covering the visual, auditory and motor cortices, created from a prior analysis, were used. Two dependent variables were compared: percent signal change and contrast-to-noise-ratio. Reliability was assessed with intraclass correlation coefficients derived from a variance components analysis. Test-retest reliability was high, but initially, between-site reliability was low, indicating a strong contribution from site and site-by-subject variance. However, a number of factors that can markedly improve between-site reliability were uncovered, including increasing the size of the ROIs, adjusting for smoothness differences, and inclusion of additional runs. By employing multiple steps, between-site reliability for 3T scanners was increased by 123%. Dropping one site at a time and assessing reliability can be a useful method of assessing the sensitivity of the results to particular sites. These findings should provide guidance toothers on the best practices for future multicenter studies.

  10. Test-Retest Reliability of Computerized, Everyday Memory Measures and Traditional Memory Tests.

    Science.gov (United States)

    Youngjohn, James R.; And Others

    Test-retest reliabilities and practice effect magnitudes were considered for nine computer-simulated tasks of everyday cognition and five traditional neuropsychological tests. The nine simulated everyday memory tests were from the Memory Assessment Clinic battery as follows: (1) simple reaction time while driving; (2) divided attention (driving…

  11. Test-Retest Reliability of the Salutogenic Wellness Promotion Scale (SWPS)

    Science.gov (United States)

    Anderson, L. M.; Moore, J. B.; Hayden, B. M.; Becker, C. M.

    2014-01-01

    Objective: This study examined the temporal stability (i.e. test-retest reliability) of the Salutogenic Wellness Promotion Scale (SWPS) using intraclass correlation coefficients (ICC). Current intraclass results were also compared to previously published interclass correlations to support the use of the intraclass method for test-retest…

  12. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Rosado, P.H.G.; Cunha, P.G. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  13. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Science.gov (United States)

    Guimarães, M. C.; Silva, C. R. E.; Rosado, P. H. G.; Cunha, P. G.; Da Silva, T. A.

    2018-03-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work.

  14. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    International Nuclear Information System (INIS)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da; Rosado, P.H.G.; Cunha, P.G.

    2017-01-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  15. TESTING METHODS FOR MECHANICALLY IMPROVED SOILS: RELIABILITY AND VALIDITY

    Directory of Open Access Journals (Sweden)

    Ana Petkovšek

    2017-10-01

    Full Text Available A possibility of in-situ mechanical improvement for reducing the liquefaction potential of silty sands was investigated by using three different techniques: Vibratory Roller Compaction, Rapid Impact Compaction (RIC and Soil Mixing. Material properties at all test sites were investigated before and after improvement with the laboratory and the in situ tests (CPT, SDMT, DPSH B, static and dynamic load plate test, geohydraulic tests. Correlation between the results obtained by different test methods gave inconclusive answers.

  16. Validity, Reliability and Standardization Study of the Language Assessment Test for Aphasia

    Directory of Open Access Journals (Sweden)

    Bülent Toğram

    2012-09-01

    Full Text Available OBJECTIVE: Aphasia assessment is the first step towards a well- founded language therapy. Language tests need to consider cultural as well as typological linguistic aspects of a given language. This study was designed to determine the standardization, validity and reliability of Language Assessment Test for Aphasia, which consists of eight subtests including spontaneous speech and language, auditory comprehension, repetition, naming, reading, grammar, speech acts, and writing. METHODS: The test was administered to 282 healthy participants and 92 aphasic participants in age, education and gender matched groups. The validity study of the test was investigated with analysis of content, structure and criterion-related validity. For reliability of the test, the analysis of internal consistency, stability and equivalence reliability was conducted. The influence of variables on healhty participants’ sub-test scores, test score and language score was examined. According to significant differences, norms and cut-off scores based on language score were determined. RESULTS: The group with aphasia performed highly lower than healthy participants on subtest, test and language scores. The test scores of healthy group were mostly affected by age and educational level but not affected by gender. According to significant differences, age and educational level for both groups were determined. Considering age and educational levels, the reference values for the cut-off scores were presented. CONCLUSION: The test was found to be a highly reliable and valid aphasia test for Turkish- speaking aphasic patients either in Turkey or other Turkish communities around the world

  17. Reliability testing of the Danish version of the Kidney Disease Quality of Life Short Form

    DEFF Research Database (Denmark)

    Molsted, Stig; Heaf, James; Prescott, Lotte

    2005-01-01

    . MATERIAL AND METHODS: Translation into Danish and back-translation into English were performed. Pilot, field and internal consistency reliability tests were performed. RESULTS: Cronbach's alpha coefficients for the internal reliability test ranged from 0.77 to 0.93 for the eight generic scales. In a test......OBJECTIVE: The questionnaire Kidney Disease Quality of Life Short Form version 1.3 (KDQOL-SF) is valuable for assessing the health-related quality of life in patients treated with chronic dialysis. The aim of this study was to translate and test the reliability of the KDQOL-SF for use in Denmark...... involving all patients, two of the disease-specific scales had Cronbach's alpha coefficients of test of the scores...

  18. Data mining-based coefficient of influence factors optimization of test paper reliability

    Science.gov (United States)

    Xu, Peiyao; Jiang, Huiping; Wei, Jieyao

    2018-05-01

    Test is a significant part of the teaching process. It demonstrates the final outcome of school teaching through teachers' teaching level and students' scores. The analysis of test paper is a complex operation that has the characteristics of non-linear relation in the length of the paper, time duration and the degree of difficulty. It is therefore difficult to optimize the coefficient of influence factors under different conditions in order to get text papers with clearly higher reliability with general methods [1]. With data mining techniques like Support Vector Regression (SVR) and Genetic Algorithm (GA), we can model the test paper analysis and optimize the coefficient of impact factors for higher reliability. It's easy to find that the combination of SVR and GA can get an effective advance in reliability from the test results. The optimal coefficient of influence factors optimization has a practicability in actual application, and the whole optimizing operation can offer model basis for test paper analysis.

  19. Irradiation effects test Series Scoping Test 1: test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.

    1977-09-01

    The report describes the results of the first scoping test in the Irradiation Effects Test Series conducted by the Thermal Fuels Behavior Program, which is part of the Water Reactor Research Program of EG and G Idaho, Inc. The research is sponsored by the United States Nuclear Regulatory Commission. This test used an unirradiated, three-foot-long, PWR-type fuel rod. The objective of this test was to thoroughly evaluate the remote fabrication procedures to be used for irradiated rods in future tests, handling plans, and reactor operations. Additionally, selected fuel behavior data were obtained. The fuel rod was subjected to a series of preconditioning power cycles followed by a power increase which brought the fuel rod power to about 20.4 kW/ft peak linear heat rating at a coolant mass flux of 1.83 x 10 6 lb/hr-ft 2 . Film boiling occurred for a period of 4.8 minutes following flow reductions to 9.6 x 10 5 and 7.5 x 10 5 lb/hr-ft 2 . The test fuel rod failed following reactor shutdown as a result of heavy internal and external cladding oxidation and embrittlement which occurred during the film boiling operation

  20. Chemical compatibility screening test results

    International Nuclear Information System (INIS)

    Nigrey, P.J.; Dickens, T.G.

    1997-12-01

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60 degrees C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m 2 for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals

  1. Boeing's STAR-FODB test results

    Science.gov (United States)

    Fritz, Martin E.; de la Chapelle, Michael; Van Ausdal, Arthur W.

    1995-05-01

    Boeing has successfully concluded a 2 1/2 year, two phase developmental contract for the STAR-Fiber Optic Data Bus (FODB) that is intended for future space-based applications. The first phase included system analysis, trade studies, behavior modeling, and architecture and protocal selection. During this phase we selected AS4074 Linear Token Passing Bus (LTPB) protocol operating at 200 Mbps, along with the passive, star-coupled fiber media. The second phase involved design, build, integration, and performance and environmental test of brassboard hardware. The resulting brassboard hardware successfully passed performance testing, providing 200 Mbps operation with a 32 X 32 star-coupled medium. This hardware is suitable for a spaceflight experiment to validate ground testing and analysis and to demonstrate performace in the intended environment. The fiber bus interface unit (FBIU) is a multichip module containing transceiver, protocol, and data formatting chips, buffer memory, and a station management controller. The FBIU has been designed for low power, high reliability, and radiation tolerance. Nine FBIUs were built and integrated with the fiber optic physical layer consisting of the fiber cable plant (FCP) and star coupler assembly (SCA). Performance and environmental testing, including radiation exposure, was performed on selected FBIUs and the physical layer. The integrated system was demonstrated with a full motion color video image transfer across the bus while simultaneously performing utility functions with a fiber bus control module (FBCM) over a telemetry and control (T&C) bus, in this case AS1773.

  2. Irradiation effects test series, test IE-5. Test results report

    International Nuclear Information System (INIS)

    Croucher, D.W.; Yackle, T.R.; Allison, C.M.; Ploger, S.A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m 2 for each rod. After a flow reduction to 1800 kg/s-m 2 , film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m 2 produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results

  3. RELIABILITY OF CERTAIN TESTS FOR EVALUATION OF JUDO TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Slavko Obadov

    2007-05-01

    Full Text Available The sample included 106 judokas. Assessment of the level of mastership of judo techniques was carried out by evaluation of fi ve competent studies. Each subject performed a technique three times and each performance was evaluated by the judges. In order to evaluate measurement of each technique, Cronbach’s coeffi cient of reliability  was calculated. During the procedure the subjects's results were also transformed to factor scores i.e. the results of each performer at the main component of evaluation in the fi ve studies. These factor scores could be used in the subsequent procedure of multivariant statistical analysis.

  4. Reliability and Validity of the Inline Skating Skill Test

    Directory of Open Access Journals (Sweden)

    Ivan Radman, Lana Ruzic, Viktoria Padovan, Vjekoslav Cigrovski, Hrvoje Podnar

    2016-09-01

    Full Text Available This study aimed to examine the reliability and validity of the inline skating skill test. Based on previous skating experience forty-two skaters (26 female and 16 male were randomized into two groups (competitive level vs. recreational level. They performed the test four times, with a recovery time of 45 minutes between sessions. Prior to testing, the participants rated their skating skill using a scale from 1 to 10. The protocol included performance time measurement through a course, combining different skating techniques. Trivial changes in performance time between the repeated sessions were determined in both competitive females/males and recreational females/males (-1.7% [95% CI: -5.8–2.6%] – 2.2% [95% CI: 0.0–4.5%]. In all four subgroups, the skill test had a low mean within-individual variation (1.6% [95% CI: 1.2–2.4%] – 2.7% [95% CI: 2.1–4.0%] and high mean inter-session correlation (ICC = 0.97 [95% CI: 0.92–0.99] – 0.99 [95% CI: 0.98–1.00]. The comparison of detected typical errors and smallest worthwhile changes (calculated as standard deviations × 0.2 revealed that the skill test was able to track changes in skaters’ performances. Competitive-level skaters needed shorter time (24.4–26.4%, all p < 0.01 to complete the test in comparison to recreational-level skaters. Moreover, moderate correlation (ρ = 0.80–0.82; all p < 0.01 was observed between the participant’s self-rating and achieved performance times. In conclusion, the proposed test is a reliable and valid method to evaluate inline skating skills in amateur competitive and recreational level skaters. Further studies are needed to evaluate the reproducibility of this skill test in different populations including elite inline skaters.

  5. Railgun bore material test results

    International Nuclear Information System (INIS)

    Wang, S.Y.; Burton, R.L.; Witherspoon, F.D.; Bloomberg, H.W.; Goldstein, S.A.; Tidman, D.A.; Winsor, N.K.

    1987-01-01

    GT-Devices, Inc. has constructed a material test facility (MTF) to study the fundamental heat transfer problem of both railgun and electrothermal guns, and to test candidate gun materials under real plasma conditions. The MTF electrothermally produces gigawatt-level plasmas with pulse lengths of 10-30 microseconds. Circular bore and non-circular bore test barrels have been successfully operated under a wide range of simulated heating environments for EM launchers. Diagnostics include piezoelectric MHz pressure probes, time-of-flight probes, and current and voltage probes. Ablation measurements are accomplished by weighing and optical inspection, including borescope, optical microscope, and scanning electron microscope (SEM). From these measurements the ablation threshold for both the rail and insulator materials can be determined as a function of plasma heating. The MTF diagnostics are supported by an unsteady 1-D model of MTF which uses the flux-corrected transport (FCT) algorithm to calculate the fluid equations in conservative form. A major advantage of the FCT algorithm is that it can model gas dynamic shock behaviour without the requirement of numerical diffusion. The principle use of the code is to predict the material surface temperature ΔT/α from the unsteady heat transfer q(t)

  6. Boraflex test results and evaluation

    International Nuclear Information System (INIS)

    Lindquist, K.; Kline, D.E.; Haley, T.C.

    1993-02-01

    New data developed, collected, and evaluated to further assess the in-pool performance of the neutron absorber material, Boraflex. The data are from new EPRI test programs, utility surveillance programs, and blackness testing at a number of plants. This new data provides a basis for quantifying the gap phenomenon in full length panels of Boraflex in spent fuel racks; the maximum anticipated gap size, frequency of gap occurrence, and axial distribution of gaps. Methods have been developed to assess the reactivity effects of gaps and Boraflex shrinkage. The analyses presented demonstrates that the reactivity effect of gaps is very small, not much larger than the statistical variations inherent in the calculational method. The data and analyses presented serve to close the issue of gap formation and shrinkage in panels of Boraflex and the effect of such gaps and shrinkage on the reactivity of the fuel/rack configuration. Ongoing EPRI programs to assess the long term performance of Boraflex in spent fuel storage racks are described

  7. A New Tool for Nutrition App Quality Evaluation (AQEL): Development, Validation, and Reliability Testing.

    Science.gov (United States)

    DiFilippo, Kristen Nicole; Huang, Wenhao; Chapman-Novakofski, Karen M

    2017-10-27

    The extensive availability and increasing use of mobile apps for nutrition-based health interventions makes evaluation of the quality of these apps crucial for integration of apps into nutritional counseling. The goal of this research was the development, validation, and reliability testing of the app quality evaluation (AQEL) tool, an instrument for evaluating apps' educational quality and technical functionality. Items for evaluating app quality were adapted from website evaluations, with additional items added to evaluate the specific characteristics of apps, resulting in 79 initial items. Expert panels of nutrition and technology professionals and app users reviewed items for face and content validation. After recommended revisions, nutrition experts completed a second AQEL review to ensure clarity. On the basis of 150 sets of responses using the revised AQEL, principal component analysis was completed, reducing AQEL into 5 factors that underwent reliability testing, including internal consistency, split-half reliability, test-retest reliability, and interrater reliability (IRR). Two additional modifiable constructs for evaluating apps based on the age and needs of the target audience as selected by the evaluator were also tested for construct reliability. IRR testing using intraclass correlations (ICC) with all 7 constructs was conducted, with 15 dietitians evaluating one app. Development and validation resulted in the 51-item AQEL. These were reduced to 25 items in 5 factors after principal component analysis, plus 9 modifiable items in two constructs that were not included in principal component analysis. Internal consistency and split-half reliability of the following constructs derived from principal components analysis was good (Cronbach alpha >.80, Spearman-Brown coefficient >.80): behavior change potential, support of knowledge acquisition, app function, and skill development. App purpose split half-reliability was .65. Test-retest reliability showed no

  8. Testing the reliability of information extracted from ancient zircon

    Science.gov (United States)

    Kielman, Ross; Whitehouse, Martin; Nemchin, Alexander

    2015-04-01

    Studies combining zircon U-Pb chronology, trace element distribution as well as O and Hf isotope systematics are a powerful way to gain understanding of the processes shaping Earth's evolution, especially in detrital populations where constraints from the original host are missing. Such studies of the Hadean detrital zircon population abundant in sedimentary rocks in Western Australia have involved analysis of an unusually large number of individual grains, but also highlighted potential problems with the approach, only apparent when multiple analyses are obtained from individual grains. A common feature of the Hadean as well as many early Archaean zircon populations is their apparent inhomogeneity, which reduces confidence in conclusions based on studies combining chemistry and isotopic characteristics of zircon. In order to test the reliability of information extracted from early Earth zircon, we report results from one of the first in-depth multi-method study of zircon from a relatively simple early Archean magmatic rock, used as an analogue to ancient detrital zircon. The approach involves making multiple SIMS analyses in individual grains in order to be comparable to the most advanced studies of detrital zircon populations. The investigated sample is a relatively undeformed, non-migmatitic ca. 3.8 Ga tonalite collected a few kms south of the Isua Greenstone Belt, southwest Greenland. Extracted zircon grains can be combined into three different groups based on the behavior of their U-Pb systems: (i) grains that show internally consistent and concordant ages and define an average age of 3805±15 Ma, taken to be the age of the rock, (ii) grains that are distributed close to the concordia line, but with significant variability between multiple analyses, suggesting an ancient Pb loss and (iii) grains that have multiple analyses distributed along a discordia pointing towards a zero intercept, indicating geologically recent Pb-loss. This overall behavior has

  9. Irradiation Effects Test Series: Test IE-3. Test results report

    International Nuclear Information System (INIS)

    Farrar, L.C.; Allison, C.M.; Croucher, D.W.; Ploger, S.A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m 2 . After a flow reduction to 2120 kg/s-m 2 , film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions

  10. Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.

    Science.gov (United States)

    Taylor, Karen; Bulsara, Max; Monterosso, Leanne

    2018-01-01

    Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.

  11. Reliability of the Test of Wheeled Mobility (TOWM) and the Short Wheelie Test

    NARCIS (Netherlands)

    Fliess-Douer, Osnat; Van der Woude, Lucas H. V.; Vanlandewijck, Yves C.

    Objective: To assess the reliability of the Test of Wheeled Mobility (TOWM) and the Wheelie test. Design: Cohort study. Setting: Gymnasium. Participants: Manual wheelchair users (N=30, age 23-53y) with a spinal cord injury. Intervention: Participants performed the 30 skills of the TOWM and the 8

  12. Reliability of skin testing as a measure of nutritional state

    International Nuclear Information System (INIS)

    Forse, R.A.; Christou, N.; Meakins, J.L.; MacLean, L.D.; Shizgal, H.M.

    1981-01-01

    The reliability of skin testing to assess the nutritional state was evaluated in 257 patients who received total parenteral nutrition (TPN). The nutritional state was assessed by determining body composition, by multiple-isotope dilution. Immunocompetence was simultaneously evaluated by skin testing with five recall antigens. These measurements were carried out before and at two-week intervals during TPN. A statistically significant relationship existed between the response to skin testing and the nutritional state. A body composition consistent with malnutrition was present in the anergic patients, while body composition was normal in the patients who reacted normally to skin testing. However, a considerable overlap existed as 43% of the reactive patients were malnourished, and 21% of the anergic patients were normally nourished. Thirty-seven (43%) of the 86 anergic patients converted and became reactive during TPN, and their body composition improved significantly. The remaining 49 anergic patients (57%) did not convert, and their body composition did not change despite similar nutritional support. The principal difference between the two groups of anergic patients was the nature of the therapy administered. In the anergic patients who converted, therapy was aggressive and appropriate, and clinical improvement occurred in 23 (62.2%) of the patients, with a mortality of 5.4%. In the 49 patients who remained anergic, therapy was often inappropriate or unsuccessful, with clinical improvement in only three (6.1%) of the patients and a mortality of 42.8%. The data demonstrated a significant relationship between the response to skin testing and the nutritional state. However, because of the wide overlap, skin testing does not accurately assess a person's nutritional state. The persistence of the anergic state is indicative of a lack of response to therapy

  13. Reliability and Validity of the Inline Skating Skill Test.

    Science.gov (United States)

    Radman, Ivan; Ruzic, Lana; Padovan, Viktoria; Cigrovski, Vjekoslav; Podnar, Hrvoje

    2016-09-01

    This study aimed to examine the reliability and validity of the inline skating skill test. Based on previous skating experience forty-two skaters (26 female and 16 male) were randomized into two groups (competitive level vs. recreational level). They performed the test four times, with a recovery time of 45 minutes between sessions. Prior to testing, the participants rated their skating skill using a scale from 1 to 10. The protocol included performance time measurement through a course, combining different skating techniques. Trivial changes in performance time between the repeated sessions were determined in both competitive females/males and recreational females/males (-1.7% [95% CI: -5.8-2.6%] - 2.2% [95% CI: 0.0-4.5%]). In all four subgroups, the skill test had a low mean within-individual variation (1.6% [95% CI: 1.2-2.4%] - 2.7% [95% CI: 2.1-4.0%]) and high mean inter-session correlation (ICC = 0.97 [95% CI: 0.92-0.99] - 0.99 [95% CI: 0.98-1.00]). The comparison of detected typical errors and smallest worthwhile changes (calculated as standard deviations × 0.2) revealed that the skill test was able to track changes in skaters' performances. Competitive-level skaters needed shorter time (24.4-26.4%, all p skating skills in amateur competitive and recreational level skaters. Further studies are needed to evaluate the reproducibility of this skill test in different populations including elite inline skaters.

  14. Irradiation Effects Test Series: Test IE-2. Test results report

    International Nuclear Information System (INIS)

    Allison, C.M.; Croucher, D.W.; Ploger, S.A.; Mehner, A.S.

    1977-08-01

    The report describes the results of a test using four 0.97-m long PWR-type fuel rods with differences in diametral gap and cladding irradiation. The objective of this test was to provide information about the effects of these differences on fuel rod behavior during quasi-equilibrium and film boiling operation. The fuel rods were subjected to a series of preconditioning power cycles of less than 30 kW/m. Rod powers were then increased to 68 kW/m at a coolant mass flux of 4900 kg/s-m 2 . After one hour at 68 kW/m, a power-cooling-mismatch sequence was initiated by a flow reduction at constant power. At a flow of 2550 kg/s-m 2 , the onset of film boiling occurred on one rod, Rod IE-011. An additional flow reduction to 2245 kg/s-m 2 caused the onset of film boiling on the remaining three rods. Data are presented on the behavior of fuel rods during quasiequilibrium and during film boiling operation. The effects of initial gap size, cladding irradiation, rod power cycling, a rapid power increase, and sustained film boiling are discussed. These discussions are based on measured test data, preliminary postirradiation examination results, and comparisons of results with FRAP-T3 computer model calculations

  15. Test-retest reliability of a balance testing protocol with external perturbations in young healthy adults.

    Science.gov (United States)

    Robbins, Shawn M; Caplan, Ryan M; Aponte, Daniel I; St-Onge, Nancy

    2017-10-01

    External perturbations are utilized to challenge balance and mimic realistic balance threats in patient populations. The reliability of such protocols has not been established. The purpose was to examine test-retest reliability of balance testing with external perturbations. Healthy adults (n=34; mean age 23 years) underwent balance testing over two visits. Participants completed ten balance conditions in which the following parameters were combined: perturbation or non-perturbation, single or double leg, and eyes open or closed. Three trials were collected for each condition. Data were collected on a force plate and external perturbations were applied by translating the plate. Force plate center of pressure (CoP) data were summarized using 13 different CoP measures. Test-retest reliability was examined using intraclass correlation coefficients (ICC) and Bland-Altman plots. CoP measures of total speed and excursion in both anterior-posterior and medial-lateral directions generally had acceptable ICC values for perturbation conditions (ICC=0.46 to 0.87); however, many other CoP measures (e.g. range, area of ellipse) had unacceptable test-retest reliability (ICCbalance testing protocols that include external perturbations should be made to improve test-retest reliability and diminish learning including more extensive participant training and increasing the number of trials. CoP measures that consider all data points (e.g. total speed) are more reliable than those that only consider a few data points. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. A prototype tap test imaging system: Initial field test results

    Science.gov (United States)

    Peters, J. J.; Barnard, D. J.; Hudelson, N. A.; Simpson, T. S.; Hsu, D. K.

    2000-05-01

    This paper describes a simple, field-worthy tap test imaging system that gives quantitative information about the size, shape, and severity of defects and damages. The system consists of an accelerometer, electronic circuits for conditioning the signal and measuring the impact duration, a laptop PC and data acquisition and processing software. The images are generated manually by tapping on a grid printed on a plastic sheet laid over the part's surface. A mechanized scanner is currently under development. The prototype has produced images for a variety of aircraft composite and metal honeycomb structures containing flaws, damages, and repairs. Images of the local contact stiffness, deduced from the impact duration using a spring model, revealed quantitatively the stiffness reduction due to flaws and damages, as well as the stiffness enhancement due to substructures. The system has been field tested on commercial and military aircraft as well as rotor blades and engine decks on helicopters. Field test results will be shown and the operation of the system will be demonstrated.—This material is based upon work supported by the Federal Aviation Administration under Contract #DTFA03-98-D-00008, Delivery Order No. IA016 and performed at Iowa State University's Center for NDE as part of the Center for Aviation Systems Reliability program.

  17. Salt decontamination demonstration test results

    International Nuclear Information System (INIS)

    Snell, E.B.; Heng, C.J.

    1983-06-01

    The Salt Decontamination Demonstration confirmed that the precipitation process could be used for large-scale decontamination of radioactive waste sale solution. Although a number of refinements are necessary to safely process the long-term requirement of 5 million gallons of waste salt solution per year, there were no observations to suggest that any fundamentals of the process require re-evaluation. Major accomplishments were: (1) 518,000 gallons of decontaminated filtrate were produced from 427,000 gallons of waste salt solution from tank 24H. The demonstration goal was to produce a minimum of 200,000 gallons of decontaminated salt solution; (2) cesium activity in the filtrate was reduced by a factor of 43,000 below the cesium activity in the tank 24 solution. This decontamination factor (DF) exceeded the demonstration goal of a DF greater than 10,000; (3) average strontium-90 activity in the filtrate was reduced by a factor of 26 to less than 10 3 d/m/ml versus a goal of less than 10 4 d/m/ml; and (4) the concentrated precipitate was washed to a final sodium ion concentration of 0.15 M, well below the 0.225 M upper limit for DWPF feed. These accomplishments were achieved on schedule and without incident. Total radiation exposure to personnel was less than 350 mrem and resulted primarily from sampling precipitate slurry inside tank 48. 3 references, 6 figures, 2 tables

  18. Development of an Agility Test for Badminton Players and Assessment of Its Validity and Test-Retest Reliability.

    Science.gov (United States)

    Loureiro, Luiz de França Bahia; de Freitas, Paulo Barbosa

    2016-04-01

    Badminton requires open and fast actions toward the shuttlecock, but there is no specific agility test for badminton players with specific movements. To develop an agility test that simultaneously assesses perception and motor capacity and examine the test's concurrent and construct validity and its test-retest reliability. The Badcamp agility test consists of running as fast as possible to 6 targets placed on the corners and middle points of a rectangular area (5.6 × 4.2 m) from the start position located in the center of it, following visual stimuli presented in a luminous panel. The authors recruited 43 badminton players (17-32 y old) to evaluate concurrent (with shuttle-run agility test--SRAT) and construct validity and test-retest reliability. Results revealed that Badcamp presents concurrent and construct validity, as its performance is strongly related to SRAT (ρ = 0.83, P < .001), with performance of experts being better than nonexpert players (P < .01). In addition, Badcamp is reliable, as no difference (P = .07) and a high intraclass correlation (ICC = .93) were found in the performance of the players on 2 different occasions. The findings indicate that Badcamp is an effective, valid, and reliable tool to measure agility, allowing coaches and athletic trainers to evaluate players' athletic condition and training effectiveness and possibly detect talented individuals in this sport.

  19. Reliability of cognitive tests of ELSA-Brasil, the brazilian longitudinal study of adult health

    Science.gov (United States)

    Batista, Juliana Alves; Giatti, Luana; Barreto, Sandhi Maria; Galery, Ana Roscoe Papini; Passos, Valéria Maria de Azeredo

    2013-01-01

    Cognitive function evaluation entails the use of neuropsychological tests, applied exclusively or in sequence. The results of these tests may be influenced by factors related to the environment, the interviewer or the interviewee. OBJECTIVES We examined the test-retest reliability of some tests of the Brazilian version from the Consortium to Establish a Registry for Alzheimer's disease. METHODS The ELSA-Brasil is a multicentre study of civil servants (35-74 years of age) from public institutions across six Brazilian States. The same tests were applied, in different order of appearance, by the same trained and certified interviewer, with an approximate 20-day interval, to 160 adults (51% men, mean age 52 years). The Intraclass Correlation Coefficient (ICC) was used to assess the reliability of the measures; and a dispersion graph was used to examine the patterns of agreement between them. RESULTS We observed higher retest scores in all tests as well as a shorter test completion time for the Trail Making Test B. ICC values for each test were as following: Word List Learning Test (0.56), Word Recall (0.50), Word Recognition (0.35), Phonemic Verbal Fluency Test (VFT, 0.61), Semantic VFT (0.53) and Trail B (0.91). The Bland-Altman plot showed better correlation of executive function (VFT and Trail B) than of memory tests. CONCLUSIONS Better performance in retest may reflect a learning effect, and suggest that retest should be repeated using alternate forms or after longer periods. In this sample of adults with high schooling level, reliability was only moderate for memory tests whereas the measurement of executive function proved more reliable. PMID:29213860

  20. Reliability of Cognitive Tests of ELSA-Brasil, the Brazilian Longitudinal Study of Adult Health

    Directory of Open Access Journals (Sweden)

    Juliana Alves Batista

    Full Text Available ABSTRACT Cognitive function evaluation entails the use of neuropsychological tests, applied exclusively or in sequence. The results of these tests may be influenced by factors related to the environment, the interviewer or the interviewee. Objectives: We examined the test-retest reliability of some tests of the Brazilian version from the Consortium to Establish a Registry for Alzheimer's disease. Methods: The ELSA-Brasil is a multicentre study of civil servants (35-74 years of age from public institutions across six Brazilian States. The same tests were applied, in different order of appearance, by the same trained and certified interviewer, with an approximate 20-day interval, to 160 adults (51% men, mean age 52 years. The Intraclass Correlation Coefficient (ICC was used to assess the reliability of the measures; and a dispersion graph was used to examine the patterns of agreement between them. Results: We observed higher retest scores in all tests as well as a shorter test completion time for the Trail Making Test B. ICC values for each test were as following: Word List Learning Test (0.56, Word Recall (0.50, Word Recognition (0.35, Phonemic Verbal Fluency Test (VFT, 0.61, Semantic VFT (0.53 and Trail B (0.91. The Bland-Altman plot showed better correlation of executive function (VFT and Trail B than of memory tests. Conclusions: Better performance in retest may reflect a learning effect, and suggest that retest should be repeated using alternate forms or after longer periods. In this sample of adults with high schooling level, reliability was only moderate for memory tests whereas the measurement of executive function proved more reliable.

  1. Reliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people

    Directory of Open Access Journals (Sweden)

    Boneth M

    2012-05-01

    Full Text Available Objective: to assess the test-retest reliability and level of agreement between measures of the 30 second (30-s Arm Curl and 30-s Chair Stand test in a sample of older adults from Bucaramanga. Materials and methods: a study of evaluation of diagnostic technology was done. Both tests were administered by the same evaluator to 111 adults older than 59 year-old (70,4 ± 7,3, on two occasions, with an interval of time between measures of 4 to 8 days. In the analysis, test-retest reliability was determined using the Intraclass Correlation Coefficient ICC= 2,1 with their confidence interval 95% (CI 95% respective. The agreement level was established by the Bland and Altman method. Results: the test-retest reproducibility of the 30-s Arm Curl test was very good ICC= 0,88 and to the Chair Stand test was good ICC= 0,78. The agreement was very good for both tests of muscle endurance. The CI 95% were between -3,8 and 3,2 stands to 30-s Chair Stand test and between -3,1 and 2,8 curls to 30-s Arm Curl test. Conclusion: the 30-s Arm Curl and 30-s Chair Stand test have good reliability and agreement to assess muscle endurance in older adults functionally independent.

  2. Reliability and normative values of the foot line test: a technique to assess foot posture

    DEFF Research Database (Denmark)

    Brushøj, C; Larsen, Klaus; Nielsen, MB

    2007-01-01

    STUDY DESIGN: Test-retest reliability. OBJECTIVE: To examine the reliability and report normative values of a novel test, the foot line test (FLT), to describe foot morphology. BACKGROUND: Numerous foot examinations are performed each day, but most existing examination techniques have considerable...... limitations regarding reliability and validity. METHODS: One hundred thirty subjects with mean foot size 44 (41-50 European size) participated. Two examiners, blinded to each other's measurements, measured the right foot of the subjects twice and the left foot once. The position of the most medial aspect...... of the navicular in the mediolateral direction was projected vertically onto a piece of paper placed under the subject's foot, and compared to the position of the forefoot and hindfoot to obtain the FLT value. RESULTS: FLT values ranged from -8 to 14 mm, with a mean (+/-SD) of 3.7 +/- 3.4 mm. The intratester...

  3. Reliability test: X-ray ring exit chambers crotch radiation absorbers. Final report

    International Nuclear Information System (INIS)

    Lynch, D.R.; Morgan, J.

    1999-01-01

    This report details the efforts by engineers at the National Synchrotron Light Source (NSLS) of Brookhaven National Laboratory (BNL) to evaluate the reliability of water-cooled radiation absorbers used in the NSLS X-ray ring. These absorbers are part of the 16 dipole vacuum chambers which comprise the arc sections of the ring. They are located at the intersections (crotch) of the beamline exit ports with the electron beam chamber, and are commonly referred to as crotches. The purpose of these efforts was to demonstrate the reliability of the crotches under operating conditions that the crotches will be subjected to over the entire expected life of the ring. The efforts described include engineering calculations, finite element analysis, conceptual design for a reliability test, test implementation and descriptions, results and conclusions related to these analyses and tests

  4. Test-retest reliability of the Progressive Isoinertial Lifting Evaluation (PILE).

    Science.gov (United States)

    Lygren, Hildegunn; Dragesund, Tove; Joensen, Jón; Ask, Tove; Moe-Nilssen, Rolf

    2005-05-01

    A repeated measures single group design. To investigate test-retest reliability of Progressive Isoinertial Lifting Evaluation on patients with long lasting musculoskeletal problems related to the lumbar spine. Test-retest reliability has been satisfactory in healthy men. Test-retest reliability for clinical populations has not been reported. A total of 31 patients (17 women and 14 men) with long lasting low back pain participated in the study. The patients were tested twice at an interval of 2 days and at the same time of the day. The heaviest load that the patient could lift 4 times was used as outcome measure. The error of measurement indicates that the true result in 95% of cases will be within +/-4.5 kg from the measured value, while the difference between 2 measurements in 95% of cases will be less than 6.4 kg. Intra-class correlation (1,1) was 0.91. Relative test-retest reliability was high assessed by intra-class correlation, but absolute measurement variability reported as the smallest detectable difference has relevance for the interpretation of clinical test results and should also be considered.

  5. Test - retest reliability of two instruments for measuring public attitudes towards persons with mental illness

    Directory of Open Access Journals (Sweden)

    Leufstadius Christel

    2011-01-01

    Full Text Available Abstract Background Research has identified stigmatization as a major threat to successful treatment of individuals with mental illness. As a consequence several anti-stigma campaigns have been carried out. The results have been discouraging and the field suffers from lack of evidence about interventions that work. There are few reports on psychometric data for instruments used to assess stigma, which thus complicates research efforts. The aim of the present study was to investigate test-retest reliability of the Swedish versions of the questionnaires: FABI and "Changing Minds" and to examine the internal consistency of the two instruments. Method Two instruments, fear and behavioural intentions (FABI and "Changing Minds", used in earlier studies on public attitudes towards persons with mental illness were translated into Swedish and completed by 51 nursing students on two occasions, with an interval of three weeks. Test-retest reliability was calculated by using weighted kappa coefficient and internal consistency using the Cronbach's alpha coefficient. Results Both instruments attain at best moderate test-retest reliability. For the Changing Minds questionnaire almost one fifth (17.9% of the items present poor test-retest reliability and the alpha coefficient for the subscales ranges between 0.19 - 0.46. All of the items in the FABI reach a fair or a moderate agreement between the test and retest, and the questionnaire displays a high internal consistency, alpha 0.80. Conclusions There is a need for development of psychometrically tested instruments within this field of research.

  6. Reliability of nondestructive testing of metal strength properties for power equipment

    International Nuclear Information System (INIS)

    Bugaj, N.V.; Lebedev, A.A.; Sharko, A.V.

    1985-01-01

    Ultrasonic control which is a constituent part of a complex control system which includes specimen-free (by hardness) tests, random breaking tests and acoustic measurements is stUdied for its reliability with respect to strength properties of power-equipment metal. Quantitative and alternative criteria are developed to estimate quality of elements for power-equipment according to results of metal strength properties. Acoustic control results are presented for ultimate strength in 12Kh1MF-steel

  7. Intersession reliability of self-selected and narrow stance balance testing in older adults.

    Science.gov (United States)

    Riemann, Bryan L; Piersol, Kelsey

    2017-10-01

    Despite the common practice of using force platforms to assess balance of older adults, few investigations have examined the reliability of postural screening tests in this population. We sought to determine the test-retest reliability of self-selected and narrow stance balance testing with eyes open and eyes closed in healthy older adults. Thirty older adults (>65 years) completed 45 s trials of eyes open and eyes closed stability tests using self-selected and narrow stances on two separate days (1.9 ± .7 days). Average medial-lateral center of pressure velocity was computed. The ICC results ranged from .74 to .86, and no significant systematic changes (P eyes open and closed balance testing using self-selected and narrow stances in older adults was established which should provide a foundation for the development of fall risk screening tests.

  8. Applying reliability centered maintenance analysis principles to inservice testing

    International Nuclear Information System (INIS)

    Flude, J.W.

    1994-01-01

    Federal regulations require nuclear power plants to use inservice test (IST) programs to ensure the operability of safety-related equipment. IST programs are based on American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code requirements. Many of these plants also use Reliability Centered Maintenance (RCM) to optimize system maintenance. ASME Code requirements are hard to change. The process for requesting authority to use an alternate strategy is long and expensive. The difficulties of obtaining this authority make the use of RCM method on safety-related systems not cost effective. An ASME research task force on Risk Based Inservice Testing is investigating changing the Code. The change will allow plants to apply RCM methods to the problem of maintenance strategy selection for safety-related systems. The research task force is working closely with the Codes and Standards sections to develop a process related to the RCM process. Some day plants will be able to use this process to develop more efficient and safer maintenance strategies

  9. Reasoning with Inductive Argument Test: A Study of Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Mehmet Emrah Karadere

    2013-11-01

    Full Text Available Reasoning with Inductive Argument Test:A Study of Validity and Reliability Objective: The aim of our study is to research reliability and validity and to evaluate the usability of Turkish version of Reasoning with Inductive Argument Test (RIAT in Turkish healty population. Method: 51 healty volunteers who work in Ankara Dıskapi Yildirim Beyazit Research and Training Hospital participated in this study. Reasoning with Inductive Argument Test (RIAT was translated into Turkish by three clinical good knowledge of English. Participants were given a sociodemographic data form, and RIAT were performed by clinicians. To test the reliability of the Turkish version of RIAT, Cronbach’s alpha coefficient was calculated and the halving method was used for the test. Results: The internal consistency of the Reasoning with Inductive Argument Test (RIAT items, Cronbach’s alpha internal consistency coefficient measurements of 0.73 was found to be statistically significant. Spearman-Brown coefficient that determines the reliability of the whole test r=0.74 was found. Kurtosis values of all the items was below 1.5 and the percentages in the second evaluation were mainly lower. At the same time, both change in belief between self produced RIAT options and given RIAT options (p=0.02, z=-2296 as well as changes in beliefs between related and unrelated items for Obsessive Compulsive Disorder (OCD difference (p=0.03, z=-2.199 were significant. Conclusion: The preliminary data obtained from the study of reliability and validity of the scale shows that ‘Reasoning with Inductive Argument Test’ supports reliability and validity in Turkish population.

  10. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan.

    Science.gov (United States)

    Moore, Amy Lawson; Miller, Terissa M

    2018-01-01

    The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.

  11. CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.

    Science.gov (United States)

    Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David

    2016-03-01

    Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC 2 ,: 1  = 0.59) over Bath-Thermode (ICC 2 ,: 1  = 0.34) or Two-Thermodes (ICC 2 ,: 1  = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC 2 ,: 1  = 0.76 vs ICC 2 ,: 1  = 0.16). Conditioned test-stimulus pain scores were of good (ICC 2 ,: 1  = 0.62) or fair (ICC 2 ,: 1  = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC 2 ,: 1  = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e

  12. Testing the reliability of ice-cream cone model

    Science.gov (United States)

    Pan, Zonghao; Shen, Chenglong; Wang, Chuanbing; Liu, Kai; Xue, Xianghui; Wang, Yuming; Wang, Shui

    2015-04-01

    Coronal Mass Ejections (CME)'s properties are important to not only the physical scene itself but space-weather prediction. Several models (such as cone model, GCS model, and so on) have been raised to get rid of the projection effects within the properties observed by spacecraft. According to SOHO/ LASCO observations, we obtain the 'real' 3D parameters of all the FFHCMEs (front-side full halo Coronal Mass Ejections) within the 24th solar cycle till July 2012, by the ice-cream cone model. Considering that the method to obtain 3D parameters from the CME observations by multi-satellite and multi-angle has higher accuracy, we use the GCS model to obtain the real propagation parameters of these CMEs in 3D space and compare the results with which by ice-cream cone model. Then we could discuss the reliability of the ice-cream cone model.

  13. Design of Accelerated Reliability Test for CNC Motorized Spindle Based on Vibration Signal

    Directory of Open Access Journals (Sweden)

    Chen Chao

    2016-01-01

    Full Text Available Motorized spindle is the key functional component of CNC machining centers which is a mechatronics system with long life and high reliability. The reliability test cycle of motorized spindle is too long and infeasible. This paper proposes a new accelerated test for reliability evaluation of motorized spindle. By field reliability test, authors collect and calculate the load data including rotational speed, cutting force and torque. Load spectrum distribution law is analyzed. And authors design a test platform to apply the load spectrum. A new method to define the fuzzy acceleration factor based on the vibration signal is proposed. Then the whole test plan of accelerated reliability test is done.

  14. Reliability of the "Ten Test" for assessment of discriminative sensation in hand trauma.

    Science.gov (United States)

    Berger, Michael J; Regan, William R; Seal, Alex; Bristol, Sean G

    2016-10-01

    "Ten Test" (TT) is a bedside measure of discriminative sensation, whereby the magnitude of abnormal sensation to moving light touch is normalized to an area of normal sensation on an 11-point Likert scale (0-10). The purposes of this study were to determine reliability parameters of the TT in a cohort of patients presenting to a hand trauma clinic with subjectively altered sensation post-injury and to compare the reliability of TT to that of the Weinstein Enhanced Sensory Test (WEST). Study participants (n = 29, mean age = 37 ± 12) comprised patients presenting to an outpatient hand trauma clinic with recent hand trauma and self reported abnormal sensation. Participants underwent TT and WEST by two separate raters on the same day. Interrater reliability, response stability and responsiveness of each test were determined by the intraclass correlation coefficient (ICC: 2, 1), standard error of measurement (SEM) with 95% confidence intervals (CI) and minimal detectable difference score, with 95% CI (MDD95), respectively. The TT displayed excellent interrater reliability (ICC = 0.95, 95% CI 0.89-0.97) compared to good reliability for WEST (ICC = 0.78, 95% CI 0.58-0.89). The range of true scores expected with 95% confidence based on the SEM (i.e. response stability), was ±1.1 for TT and ±1.1 for WEST. MDD95 scores reflecting test responsiveness were 1.5 and 1.6 for TT and WEST, respectively. The TT displayed excellent reliability parameters in this patient population. Reliability parameters were stronger for TT compared to WEST. These results provide support for the use of TT as a component of the sensory exam in hand trauma. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  15. Effects of Differential Item Functioning on Examinees' Test Performance and Reliability of Test

    Science.gov (United States)

    Lee, Yi-Hsuan; Zhang, Jinming

    2017-01-01

    Simulations were conducted to examine the effect of differential item functioning (DIF) on measurement consequences such as total scores, item response theory (IRT) ability estimates, and test reliability in terms of the ratio of true-score variance to observed-score variance and the standard error of estimation for the IRT ability parameter. The…

  16. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    Science.gov (United States)

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  17. Inventory of Motive of Preference for Conventional Paper-and-Pencil Tests: A Study of Validity and Reliability

    Science.gov (United States)

    Eser, Mehmet Taha; Dogan, Nuri

    2017-01-01

    Purpose: The objective of this study is to develop the Inventory of Motive of Preference for Conventional Paper-And-Pencil Tests and to evaluate students' motives for preferring written tests, short-answer tests, true/false tests or multiple-choice tests. This will add a measurement tool to the literature with valid and reliable results to help…

  18. Reliability of a science admission test (HAM-Nat) at Hamburg medical school.

    Science.gov (United States)

    Hissbach, Johanna; Klusmann, Dietrich; Hampe, Wolfgang

    2011-01-01

    The University Hospital in Hamburg (UKE) started to develop a test of knowledge in natural sciences for admission to medical school in 2005 (Hamburger Auswahlverfahren für Medizinische Studiengänge, Naturwissenschaftsteil, HAM-Nat). This study is a step towards establishing the HAM-Nat. We are investigating parallel forms reliability, the effect of a crash course in chemistry on test results, and correlations of HAM-Nat test results with a test of scientific reasoning (similar to a subtest of the "Test for Medical Studies", TMS). 316 first-year students participated in the study in 2007. They completed different versions of the HAM-Nat test which consisted of items that had already been used (HN2006) and new items (HN2007). Four weeks later half of the participants were tested on the HN2007 version of the HAM-Nat again, while the other half completed the test of scientific reasoning. Within this four week interval students were offered a five day chemistry course. Parallel forms reliability for four different test versions ranged from r(tt)=.53 to r(tt)=.67. The retest reliabilities of the HN2007 halves were r(tt)=.54 and r(tt )=.61. Correlations of the two HAM-Nat versions with the test of scientific reasoning were r=.34 und r=.21. The crash course in chemistry had no effect on HAM-Nat scores. The results suggest that further versions of the test of natural sciences will not easily conform to the standards of internal consistency, parallel-forms reliability and retest reliability. Much care has to be taken in order to assemble items which could be used interchangeably for the construction of new test versions. The test of scientific reasoning and the HAM-Nat are tapping different constructs. Participation in a chemistry course did not improve students' achievement, probably because the content of the course was not coordinated with the test and many students lacked of motivation to do well in the second test.

  19. Abnormal Cervical Cancer Screening Test Results

    Science.gov (United States)

    ... AQ FREQUENTLY ASKED QUESTIONS FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test ...

  20. Impact on participation and autonomy: test of validity and reliability for older persons

    Directory of Open Access Journals (Sweden)

    Isabelle Ottenvall Hammar

    2014-10-01

    Full Text Available In research and healthcare it is important to measure older persons’ self-determination in order to improve their possibilities to decide for themselves in daily life. The questionnaire Impact on Participation and Autonomy (IPA assesses self-determination, but is not constructed for older persons. The aim of this study was to examine the validity and reliability of the IPA-S questionnaire for persons aged 70 years and older. The study was performed in two steps; first a validity test of the Swedish version of the questionnaire, IPA-S, followed by a reliability test-retest of an adjusted version. The validity was tested with focus groups and individual interviews on persons aged 77-88 years, and the reliability on persons aged 70-99 years. The validity test result showed that IPA-S is valid for older persons but it was too extensive and the phrasing of the items needed adjustments. The reliability test-retest on the adjusted questionnaire, IPA-Older persons (IPA-O, showed that 15 of 22 items had high agreement. IPA-O can be used to measure older persons’ self-determination in their care and rehabilitation.

  1. Reliability and smallest real difference of the ankle lunge test post ankle fracture.

    Science.gov (United States)

    Simondson, David; Brock, Kim; Cotton, Susan

    2012-02-01

    This study aimed to determine the reliability and the smallest real difference of the Ankle Lunge test in an ankle fracture patient population. In the post immobilisation stage of ankle fracture, ankle dorsiflexion is an important measure of progress and outcome. The Ankle Lunge test measures weight bearing dorsiflexion, resulting in negative scores (knee to wall distance) and positive scores (toe to wall distance), for which the latter has proven reliability in normal subjects only. A consecutive sample of ankle fracture patients with permission to commence weight bearing, were recruited to the study. Three measurements of the Ankle Lunge Test were performed each by two raters, one senior and one junior physiotherapist. These occurred prior to therapy sessions in the second week after plaster removal. A standardised testing station was utilised and allowed for both knee to wall distance and toe to wall distance measurement. Data was collected from 10 individuals with ankle fracture, with an average age of 36 years (SD 14.8). Seventy seven percent of observations were negative. Intra and inter-rater reliability yielded intra class correlations at or above 0.97, p Ankle Lunge test is a practical and reliable tool for measuring weightbearing dorsiflexion post ankle fracture. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Clinical Functional Capacity Testing in Patients With Facioscapulohumeral Muscular Dystrophy: Construct Validity and Interrater Reliability of Antigravity Tests.

    Science.gov (United States)

    Rijken, Noortje H; van Engelen, Baziel G; Weerdesteyn, Vivian; Geurts, Alexander C

    2015-12-01

    To evaluate the construct validity and interrater reliability of 4 simple antigravity tests in a small group of patients with facioscapulohumeral muscular dystrophy (FSHD). Case-control study. University medical center. Patients with various severity levels of FSHD (n=9) and healthy control subjects (n=10) were included (N=19). Not applicable. A 4-point ordinal scale was designed to grade performance on the following 4 antigravity tests: sit to stance, stance to sit, step up, and step down. In addition, the 6-minute walk test, 10-m walking test, Berg Balance Scale, and timed Up and Go test were administered as conventional tests. Construct validity was determined by linear regression analysis using the Clinical Severity Score (CSS) as the dependent variable. Interrater agreement was tested using a κ analysis. Patients with FSHD performed worse on all 4 antigravity tests compared with the controls. Stronger correlations were found within than between test categories (antigravity vs conventional). The antigravity tests revealed the highest explained variance with regard to the CSS (R(2)=.86, P=.014). Interrater agreement was generally good. The results of this exploratory study support the construct validity and interrater reliability of the proposed antigravity tests for the assessment of functional capacity in patients with FSHD taking into account the use of compensatory strategies. Future research should further validate these results in a larger sample of patients with FSHD. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  3. Reliability of externally fixed dynamometry hamstring strength testing in elite youth football players.

    Science.gov (United States)

    Wollin, Martin; Purdam, Craig; Drew, Michael K

    2016-01-01

    To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  4. Basics of Bayesian reliability estimation from attribute test data

    International Nuclear Information System (INIS)

    Martz, H.F. Jr.; Waller, R.A.

    1975-10-01

    The basic notions of Bayesian reliability estimation from attribute lifetest data are presented in an introductory and expository manner. Both Bayesian point and interval estimates of the probability of surviving the lifetest, the reliability, are discussed. The necessary formulas are simply stated, and examples are given to illustrate their use. In particular, a binomial model in conjunction with a beta prior model is considered. Particular attention is given to the procedure for selecting an appropriate prior model in practice. Empirical Bayes point and interval estimates of reliability are discussed and examples are given. 7 figures, 2 tables

  5. Test–re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females

    OpenAIRE

    Chris Beardsley; Tim Egerton; Brendon Skinner

    2016-01-01

    Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females.\\ud \\ud Method. The inter-rater reliability and test–re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart.\\ud \\ud Results. For measuring pel...

  6. Impact of Relationships between Test and Reference Animals and between Reference Animals on Reliability of Genomic Prediction

    DEFF Research Database (Denmark)

    Wu, Xiaoping; Lund, Mogens Sandø; Sun, Dongxiao

    This study investigated reliability of genomic prediction in various scenarios with regard to relationship between test and reference animals and between animals within the reference population. Different reference populations were generated from EuroGenomics data and 1288 Nordic Holstein bulls...... as a common test population. A GBLUP model and a Bayesian mixture model were applied to predict Genomic breeding values for bulls in the test data. Result showed that a closer relationship between test and reference animals led to a higher reliability, while a closer relationship between reference animal...... resulted in a lower reliability. Therefore, the design of reference population is important for improving the reliability of genomic prediction. With regard to model, the Bayesian mixture model in general led to slightly a higher reliability of genomic prediction than the GBLUP model...

  7. Isokinetic Strength and Endurance Tests used Pre- and Post-Spaceflight: Test-Retest Reliability

    Science.gov (United States)

    Laughlin, Mitzi S.; Lee, Stuart M. C.; Loehr, James A.; Amonette, William E.

    2009-01-01

    To assess changes in muscular strength and endurance after microgravity exposure, NASA measures isokinetic strength and endurance across multiple sessions before and after long-duration space flight. Accurate interpretation of pre- and post-flight measures depends upon the reliability of each measure. The purpose of this study was to evaluate the test-retest reliability of the NASA International Space Station (ISS) isokinetic protocol. Twenty-four healthy subjects (12 M/12 F, 32.0 +/- 5.6 years) volunteered to participate. Isokinetic knee, ankle, and trunk flexion and extension strength as well as endurance of the knee flexors and extensors were measured using a Cybex NORM isokinetic dynamometer. The first weekly session was considered a familiarization session. Data were collected and analyzed for weeks 2-4. Repeated measures analysis of variance (alpha=0.05) was used to identify weekly differences in isokinetic measures. Test-retest reliability was evaluated by intraclass correlation coefficients (ICC) (3,1). No significant differences were found between weeks in any of the strength measures and the reliability of the strength measures were all considered excellent (ICC greater than 0.9), except for concentric ankle dorsi-flexion (ICC=0.67). Although a significant difference was noted in weekly endurance measures of knee extension (p less than 0.01), the reliability of endurance measure by week were considered excellent for knee flexion (ICC=0.97) and knee extension (ICC=0.96). Except for concentric ankle dorsi-flexion, the isokinetic strength and endurance measures are highly reliable when following the NASA ISS protocol. This protocol should allow accurate interpretation isokinetic data even with a small number of crew members.

  8. Reliability of Health-Related Physical Fitness Tests among Colombian Children and Adolescents: The FUPRECOL Study.

    Directory of Open Access Journals (Sweden)

    Robinson Ramírez-Vélez

    Full Text Available Substantial evidence indicates that youth physical fitness levels are an important marker of lifestyle and cardio-metabolic health profiles and predict future risk of chronic diseases. The reliability physical fitness tests have not been explored in Latino-American youth population. This study's aim was to examine the reliability of health-related physical fitness tests that were used in the Colombian health promotion "Fuprecol study". Participants were 229 Colombian youth (boys n = 124 and girls n = 105 aged 9 to 17.9 years old. Five components of health-related physical fitness were measured: 1 morphological component: height, weight, body mass index (BMI, waist circumference, triceps skinfold, subscapular skinfold, and body fat (% via impedance; 2 musculoskeletal component: handgrip and standing long jump test; 3 motor component: speed/agility test (4x10 m shuttle run; 4 flexibility component (hamstring and lumbar extensibility, sit-and-reach test; 5 cardiorespiratory component: 20-meter shuttle-run test (SRT to estimate maximal oxygen consumption. The tests were performed two times, 1 week apart on the same day of the week, except for the SRT which was performed only once. Intra-observer technical errors of measurement (TEMs and inter-rater (reliability were assessed in the morphological component. Reliability for the Musculoskeletal, motor and cardiorespiratory fitness components was examined using Bland-Altman tests. For the morphological component, TEMs were small and reliability was greater than 95% of all cases. For the musculoskeletal, motor, flexibility and cardiorespiratory components, we found adequate reliability patterns in terms of systematic errors (bias and random error (95% limits of agreement. When the fitness assessments were performed twice, the systematic error was nearly 0 for all tests, except for the sit and reach (mean difference: -1.03% [95% CI = -4.35% to -2.28%]. The results from this study indicate that the

  9. Absolute and Relative Reliability of the Timed 'Up & Go' Test and '30second Chair-Stand' Test in Hospitalised Patients with Stroke

    DEFF Research Database (Denmark)

    Lyders Johansen, Katrine; Derby Stistrup, Rikke; Skibdal Schjøtt, Camilla

    2016-01-01

    OBJECTIVE: The timed 'Up & Go' test and '30second Chair-Stand' test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability...... of both tests in patients admitted to an acute stroke unit. METHODS: Sixty-two patients (men, n = 41) attended two test sessions separated by a one hours rest. Intraclass correlation coefficients (ICC2,1) were calculated to assess relative reliability. Absolute reliability was expressed as Standard Error...... of Measurement (with 95% certainty-SEM95) and Smallest Real Difference (SRD) and as percentage of their respective means if heteroscedasticity was observed in Bland Altman plots (SEM95% and SRD%). RESULTS: ICC values for interrater reliability were 0.97 and 0.99 for the timed 'Up & Go' test and 0.88 and 0...

  10. Spinal appearance questionnaire: factor analysis, scoring, reliability, and validity testing.

    Science.gov (United States)

    Carreon, Leah Y; Sanders, James O; Polly, David W; Sucato, Daniel J; Parent, Stefan; Roy-Beaudry, Marjolaine; Hopkins, Jeffrey; McClung, Anna; Bratcher, Kelly R; Diamond, Beverly E

    2011-08-15

    Cross sectional. This study presents the factor analysis of the Spinal Appearance Questionnaire (SAQ) and its psychometric properties. Although the SAQ has been administered to a large sample of patients with adolescent idiopathic scoliosis (AIS) treated surgically, its psychometric properties have not been fully evaluated. This study presents the factor analysis and scoring of the SAQ and evaluates its psychometric properties. The SAQ and the Scoliosis Research Society-22 (SRS-22) were administered to AIS patients who were being observed, braced or scheduled for surgery. Standard demographic data and radiographic measures including Lenke type and curve magnitude were also collected. Of the 1802 patients, 83% were female; with a mean age of 14.8 years and mean initial Cobb angle of 55.8° (range, 0°-123°). From the 32 items of the SAQ, 15 loaded on two factors with consistent and significant correlations across all Lenke types. There is an Appearance (items 1-10) and an Expectations factor (items 12-15). Responses are summed giving a range of 5 to 50 for the Appearance domain and 5 to 20 for the Expectations domain. The Cronbach's α was 0.88 for both domains and Total score with a test-retest reliability of 0.81 for Appearance and 0.91 for Expectations. Correlations with major curve magnitude were higher for the SAQ Appearance and SAQ Total scores compared to correlations between the SRS Appearance and SRS Total scores. The SAQ and SRS-22 Scores were statistically significantly different in patients who were scheduled for surgery compared to those who were observed or braced. The SAQ is a valid measure of self-image in patients with AIS with greater correlation to curve magnitude than SRS Appearance and Total score. It also discriminates between patients who require surgery from those who do not.

  11. Test-retest reliability of myofascial trigger point detection in hip and thigh areas.

    Science.gov (United States)

    Rozenfeld, E; Finestone, A S; Moran, U; Damri, E; Kalichman, L

    2017-10-01

    Myofascial trigger points (MTrP's) are a primary source of pain in patients with musculoskeletal disorders. Nevertheless, they are frequently underdiagnosed. Reliable MTrP palpation is the necessary for their diagnosis and treatment. The few studies that have looked for intra-tester reliability of MTrPs detection in upper body, provide preliminary evidence that MTrP palpation is reliable. Reliability tests for MTrP palpation on the lower limb have not yet been performed. To evaluate inter- and intra-tester reliability of MTrP recognition in hip and thigh muscles. Reliability study. 21 patients (15 males and 6 females, mean age 21.1 years) referred to the physical therapy clinic, 10 with knee or hip pain and 11 with pain in an upper limb, low back, shin or ankle. Two experienced physical therapists performed the examinations, blinded to the subjects' identity, medical condition and results of the previous MTrP evaluation. Each subject was evaluated four times, twice by each examiner in a random order. Dichotomous findings included a palpable taut band, tenderness, referred pain, and relevance of referred pain to patient's complaint. Based on these, diagnosis of latent MTrP's or active MTrP's was established. The evaluation was performed on both legs and included a total of 16 locations in the following muscles: rectus femoris (proximal), vastus medialis (middle and distal), vastus lateralis (middle and distal) and gluteus medius (anterior, posterior and distal). Inter- and intra-tester reliability (Cohen's kappa (κ)) values for single sites ranged from -0.25 to 0.77. Median intra-tester reliability was 0.45 and 0.46 for latent and active MTrP's, and median inter-tester reliability was 0.51 and 0.64 for latent and active MTrPs, respectively. The examination of the distal vastus medialis was most reliable for latent and active MTrP's (intra-tester k = 0.27-0.77, inter-tester k = 0.77 and intra-tester k = 0.53-0.72, inter-tester k = 0.72, correspondingly

  12. Reliability and sensitivity to change of the timed standing balance test in children with down syndrome

    Directory of Open Access Journals (Sweden)

    Vencita Priyanka Aranha

    2016-01-01

    Full Text Available Objective: To estimate the reliability and sensitivity to change of the timed standing balance test in children with Down syndrome (DS. Methods: It was a nonblinded, comparison study with a convenience sample of subjects consisting of children with DS (n = 9 aged 8–17 years. The main outcome measure was standing balance which was assessed using timed standing balance test, the time required to maintain in four conditions, eyes open static, eyes closed static, eyes open dynamic, and eyes closed dynamic. Results: Relative reliability was excellent for all four conditions with an Interclass Correlation Coefficient (ICC ranging from 0.91 to 0.93. The variation between repeated measurements for each condition was minimal with standard error of measurement (SEM of 0.21–0.59 s, suggestive of excellent absolute reliability. The sensitivity to change as measured by smallest real change (SRC was 1.27 s for eyes open static, 1.63 s for eyes closed static, 0.58 s for eyes open dynamic, and 0.61 s for eyes closed static. Conclusions: Timed standing balance test is an easy to administer test and sensitive to change with strong absolute and relative reliabilities, an important first step in establishing its utility as a clinical balance measure in children with DS.

  13. Accuracy and reliability of Tzanck test compared to histopathology for diagnosis of basal cell carcinoma

    Directory of Open Access Journals (Sweden)

    Vivek Kumar Dey

    2015-01-01

    Full Text Available Background: Histopathology is considered the gold standard for diagnosis of basal cell carcinoma (BCC but is time consuming and needs expertise to make a correct diagnosis. On the other hand, Tzanck test is a simple, easy, inexpensive and rapid test which uses exfoliative cytology to make a diagnosis. Objective: To compare the results of Tzanck test with histopathology in the diagnosis of BCC and to evaluate the diagnostic reliability and accuracy of Tzanck test in BCC. Materials and Method: Twenty-six patients with clinical suspicion of BCC were recruited. Samples for Tzanck test and histopathology were taken and diagnoses made independently. Results of Tzanck test were compared with histopathology. Results: Twenty-three cases were histopathologically proved to be BCC. Tzanck test correlated in 12 cases of BCC and could exclude all three non-BCC lesions. In 11 cases it failed to diagnose BCC. The sensitivity and specificity of Tzanck test were 52.2% and 100%, respectively, and positive and negative predictive values were 100% and 21.4%. Conclusion: Tzanck test can be recommended for initial, rapid evaluation of a clinically diagnosed case of BCC. Under experienced hands, it reliably confirms BCC. The limitation is low negative predictive value. Since it does not give information about subtypes of BCC which is of great value in therapeutic planning, histopathological confirmation is mandatory.

  14. Reliability of candida skin test in the evaluation of T-cell function in ...

    African Journals Online (AJOL)

    Ehab

    2017-01-23

    Jan 23, 2017 ... considered generally reliable under the age of 1 year.6 ... We sought to investigate the reliability of manually ... Conclusion: Candida intradermal test is a cost- effective ..... Ballow M. Historical perspectives in the diagnosis.

  15. Applications of majorization and Schur functions in reliability and life testing

    International Nuclear Information System (INIS)

    Proschan, F.

    1975-01-01

    This is an expository paper presenting basic definitions and properties of majorization and Schur functions, and displaying a variety of applications of these concepts in reliability prediction and modelling, and in reliability inference and life testing

  16. Multi-bundle shashlik calorimeter prototypes beam-test results

    International Nuclear Information System (INIS)

    Badier, J.; Bloch, P.; Bityukov, S.; Bordalo, P.; Busson, P.; Charlot, C.; Dobrzynski, L.; Golutvin, I.; Guschin, E.; Issakov, V.; Ivanchenko, I.; Klimenko, V.; Marin, V.; Moissenz, P.; Obraztsov, V.; Ostankov, A.; Popov, V.; Puljak, I.; Ramos, S.; Seez, C.; Sergueev, S.; Soushkov, V.; Tanaka, R.; Varela, J.; Virdee, T.S.; Zaitchenko, A.; Zamiatin, N.

    1995-01-01

    The first beam-test results for two- and three-bundle shashlik tower prototypes are described. We found that the spatial resolution, the uniformity of energy response, the calorimeter reliability and hermeticity and also two showers separation are improved in multi-bundle design approach. ((orig.))

  17. Test-retest reliability of the 40 Hz EEG auditory steady-state response.

    Directory of Open Access Journals (Sweden)

    Kristina L McFadden

    Full Text Available Auditory evoked steady-state responses are increasingly being used as a marker of brain function and dysfunction in various neuropsychiatric disorders, but research investigating the test-retest reliability of this response is lacking. The purpose of this study was to assess the consistency of the auditory steady-state response (ASSR across sessions. Furthermore, the current study aimed to investigate how the reliability of the ASSR is impacted by stimulus parameters and analysis method employed. The consistency of this response across two sessions spaced approximately 1 week apart was measured in nineteen healthy adults using electroencephalography (EEG. The ASSR was entrained by both 40 Hz amplitude-modulated white noise and click train stimuli. Correlations between sessions were assessed with two separate analytical techniques: a channel-level analysis across the whole-head array and b signal-space projection from auditory dipoles. Overall, the ASSR was significantly correlated between sessions 1 and 2 (p<0.05, multiple comparison corrected, suggesting adequate test-retest reliability of this response. The current study also suggests that measures of inter-trial phase coherence may be more reliable between sessions than measures of evoked power. Results were similar between the two analysis methods, but reliability varied depending on the presented stimulus, with click train stimuli producing more consistent responses than white noise stimuli.

  18. Validity and test-retest reliability of a novel simple back extensor muscle strength test.

    Science.gov (United States)

    Harding, Amy T; Weeks, Benjamin Kurt; Horan, Sean A; Little, Andrew; Watson, Steven L; Beck, Belinda Ruth

    2017-01-01

    To develop and determine convergent validity and reliability of a simple and inexpensive clinical test to quantify back extensor muscle strength. Two testing sessions were conducted, 7 days apart. Each session involved three trials of standing maximal isometric back extensor muscle strength using both the novel test and isokinetic dynamometry. Lumbar spine bone mineral density was examined by dual-energy X-ray absorptiometry. Validation was examined with Pearson correlations ( r ). Test-retest reliability was examined with intraclass correlation coefficients and limits of agreement. Pearson correlations and intraclass correlation coefficients are presented with corresponding 95% confidence intervals. Linear regression was used to examine the ability of peak back extensor muscle strength to predict indices of lumbar spine bone mineral density and strength. A total of 52 healthy adults (26 men, 26 women) aged 46.4 ± 20.4 years were recruited from the community. A strong positive relationship was observed between peak back extensor strength from hand-held and isokinetic dynamometry ( r  = 0.824, p  strength test, short- and long-term reliability was excellent (intraclass correlation coefficient = 0.983 (95% confidence interval, 0.971-0.990), p  strength measures with the novel back extensor strength protocol were -6.63 to 7.70 kg, with a mean bias of +0.71 kg. Back extensor strength predicted 11% of variance in lumbar spine bone mineral density ( p  strength ( p  strength is quick, relatively inexpensive, and reliable; demonstrates initial convergent validity in a healthy population; and is associated with bone mass at a clinically important site.

  19. Intra- and interrater reliability of the 'lumbar-locked thoracic rotation test' in competitive swimmers ages 10 through 18 years.

    Science.gov (United States)

    Feijen, Stef; Kuppens, Kevin; Tate, Angela; Baert, Isabel; Struyf, Thomas; Struyf, Filip

    2018-04-17

    Measuring thoracic spine mobility can be of interest to competitive swimmers as it has been associated with shoulder girdle function and scapular position in subjects with and without shoulder pain. At present, no reliability data of thoracic spine mobility measurements are available in the swimming population. This study aims to evaluate the within-session intra- and interrater reliability of the "lumbar-locked rotation test" for thoracic spine rotation in competitive swimmers aged 10 to 18 years. This reliability study is part of a larger prospective cohort study investigating potential risk factors for the development of shoulder pain in competitive swimmers. Within-session, intra- and inter-rater reliability. Competitive swimming clubs in Belgium. 21 competitive swimmers. Intra- and inter-rater reliability of the lumbar-locked thoracic rotation test. Intraclass correlation coefficients (ICCs) ranged from 0.91 (95% CI 0.78 to 0.96) to 0.96 (0.89-0.98) for intra-rater reliability. Results for inter-rater reliability ranged from 0.89 (0.72-0.95) to 0.86 (0.65-0.94) respectively for right and left thoracic rotation. Results suggest good to excellent reliability of the lumbar-locked thoracic rotation test, indicating this test can be used reliably in clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    .08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability...

  1. Reliability of the Test of Integrated Language and Literacy Skills (TILLS)

    Science.gov (United States)

    Mailend, Marja-Liisa; Plante, Elena; Anderson, Michele A.; Applegate, E. Brooks; Nelson, Nickola W.

    2016-01-01

    Background: As new standardized tests become commercially available, it is critical that clinicians have access to the information about a test's psychometric properties, including aspects of reliability. Aims: The purpose of the three studies reported in this article was to investigate the reliability of a new test, the Test of Integrated…

  2. Feasibility and Reliability of Physical Fitness Tests in Older Adults with Intellectual Disability: A Pilot Study

    Science.gov (United States)

    Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    2012-01-01

    Background: Physical fitness is relevant for wellbeing and health, but knowledge on the feasibility and reliability of instruments to measure physical fitness for older adults with intellectual disability is lacking. Methods: Feasibility and test-retest reliability of a physical fitness test battery (Box and Block Test, Response Time Test, walking…

  3. 75 FR 50853 - Special Conditions: Cirrus Design Corporation Model SF50 Airplane; Function and Reliability Testing

    Science.gov (United States)

    2010-08-18

    ... airplanes. 1. Function and Reliability Testing. Flight tests: In place of 14 CFR 21.35(b)(2), the following...; Function and Reliability Testing AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final special... to CAR part 3 became effective January 15, 1951, and deleted the service test requirements in Section...

  4. 75 FR 29962 - Special Conditions: Cirrus Design Corporation Model SF50 Airplane; Function and Reliability Testing

    Science.gov (United States)

    2010-05-28

    ... SF50 airplanes. 1. Function and Reliability Testing Flight tests: In place of 14 CFR part 21.35(b)(2... Reliability Testing AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed special..., 1951, and deleted the service test requirements in Section 3.19 for airplanes of 6,000 pounds maximum...

  5. Test-retest Agreement and Reliability of Quantitative Sensory Testing 1 Year After Breast Cancer Surgery

    DEFF Research Database (Denmark)

    Andersen, Kenneth Geving; Kehlet, Henrik; Aasvang, Eske Kvanner

    2015-01-01

    .5 SD) than within-patient variation (0.23 to 3.55 SD). There were no significant differences between pain and pain-free patients. The individual test-retest variability was higher on the operated side compared with the nonoperated side. DISCUSSION: The QST protocol reliability allows for group......OBJECTIVES: Quantitative sensory testing (QST) is used to assess sensory dysfunction and nerve damage by examining psychophysical responses to controlled, graded stimuli such as mechanical and thermal detection and pain thresholds. In the breast cancer population, 4 studies have used QST to examine...... persistent pain after breast cancer treatment, suggesting neuropathic pain being a prominent pain mechanism. However, the agreement and reliability of QST has not been described in the postsurgical breast cancer population, hindering exact interpretation of QST studies in this population. The aim...

  6. Seismic proving tests on the reliability for large components and equipment of nuclear power plants

    International Nuclear Information System (INIS)

    Ohno, Tokue; Tanaka, Nagatoshi

    1988-01-01

    Since Japan has destructive earthquakes frequently, the structural reliability for large components and equipment of nuclear power plants are rigorously required. They are designed using sophisticated seismic analyses and have not yet encountered a destructive earthquake. When nuclear power plants are planned, it is very important that the general public understand the structural reliability during and after an earthquake. Seismic Proving Tests have been planned by Ministry of International Trade and Industry (Miti) to comply with public requirement in Japan. A large-scale high-performance vibration table was constructed at Tasted Engineering Laboratory of Nuclear Power Engineering Test Center (NU PEC), in order to prove the structural reliability by vibrating the test model (of full scale or close to the actual size) in the condition of a destructive earthquake. As for the test models, the following four items were selected out of large components and equipment important to the safety: Reactor Containment Vessel; Primary Coolant Loop or Primary Loop Recirculation System; Reactor Pressure Vessel; and Reactor Core Internals. Here is described a brief of the vibration table, the test method and the results of the tests on PWR Reactor Containment Vessel and BWR Primary Loop Recirculation System (author)

  7. Reliability of Autonomic Responses and Malaise Across Multiple Motion Sickness Stimulation Tests

    Science.gov (United States)

    Stout, Cynthia S.; Toscano, William B.; Cowings, Patricia S.

    1993-01-01

    There is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation. Additionally, a paucity of data exists that examines the variability within an individual across repeated motion sickness tests. Investigators have also examined the relationship of autonomic responses to motion sickness development. These investigations have used analyses at discrete points in time to describe this relationship. This approach fails to address the time course of autonomic responses and malaise development throughout the motion sickness test. Our objectives were to examine the reliability of autonomic responses and malaise using the final minute of the motion sickness test across five testing occasions, to examine the reliability of the change in autonomic responses and the change in malaise across five testing occasions, and to examine the relationship between changes in autonomic responses and changes in malaise level across the entire motion sickness test. Our results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and malaise throughout the test duration were less stable across the tests. We attribute this instability to variations in individual susceptibility and the error associated with estimating a measure of autonomic gain.

  8. Evidences of validity and reliability of the Luria-Nebraska Test for Children

    Directory of Open Access Journals (Sweden)

    Ricardo Franco de Lima

    2016-01-01

    Full Text Available Abstract This paper aimed to verify evidences of validity and reliability of Luria-Nebraska Test for Children (TLN-C, in Portuguese. Three hundred eighty-seven students aged 6–13 years old, with learning difficulties, comprised the study. They were assessed with the Wechsler Intelligence Scale for Children (WISC-III and TLN-C; and effect of age differences, as well as accuracy rating by internal consistency were investigated. Age effects were found for all subtests and in the general score, except for receptive speech subtest, even when total IQ effect was controlled. Reliability analysis had satisfactory results (0.79. The TLN-C showed evidences of validity and reliability. Receptive speech subtest requires revision.

  9. "Graded Cycling Test with Talk Test" Is a Reliable Test to Monitor Cardiovascular Fitness in Patients with Minor Stroke

    DEFF Research Database (Denmark)

    Steen Krawcyk, Rikke; Vinther, Anders; Caesar Petersen, Nicolas

    2017-01-01

    variability may challenge currently used cardiovascular monitoring. The Graded Cycling Test with Talk Test is a submaximal exercise test independent of heart rate variability, shown reliable for patients with cardiac disease. METHODS: Patients diagnosed with lacunar stroke according to TOAST (Trial of Org...... a minor measurement error: 12.9 W for groups of patients (standard error of measurement, SEM95) and 18.3 W for individual patients (smallest real difference). CONCLUSION: The "Graded Cycling Test with Talk Test" is feasible and reliable for monitoring exercise effects in patients with lacunar stroke...... 10172 in Acute Stroke Treatment) criteria performed an incremental exercise test on a stationary bicycle with a 15 W (watt) increase in workload every minute. Toward the end of each incremental step, the patients recited a standardized text passage and subsequently were asked: "Are you still able...

  10. Identification of conductive hearing loss using air conduction tests alone: reliability and validity of an automatic test battery.

    Science.gov (United States)

    Convery, Elizabeth; Keidser, Gitte; Seeto, Mark; Freeston, Katrina; Zhou, Dan; Dillon, Harvey

    2014-01-01

    The primary objective of this study was to determine whether a combination of automatically administered pure-tone audiometry and a tone-in-noise detection task, both delivered via an air conduction (AC) pathway, could reliably and validly predict the presence of a conductive component to the hearing loss. The authors hypothesized that performance on the battery of tests would vary according to hearing loss type. A secondary objective was to evaluate the reliability and validity of a novel automatic audiometry algorithm to assess its suitability for inclusion in the test battery. Participants underwent a series of hearing assessments that were conducted in a randomized order: manual pure-tone air conduction audiometry and bone conduction audiometry; automatic pure-tone air conduction audiometry; and an automatic tone-in-noise detection task. The automatic tests were each administered twice. The ability of the automatic test battery to: (a) predict the presence of an air-bone gap (ABG); and (b) accurately measure AC hearing thresholds was assessed against the results of manual audiometry. Test-retest conditions were compared to determine the reliability of each component of the automatic test battery. Data were collected on 120 ears from normal-hearing and conductive, sensorineural, and mixed hearing-loss subgroups. Performance differences between different types of hearing loss were observed. Ears with a conductive component (conductive and mixed ears) tended to have normal signal to noise ratios (SNR) despite impaired thresholds in quiet, while ears without a conductive component (normal and sensorineural ears) demonstrated, on average, an increasing relationship between their thresholds in quiet and their achieved SNR. Using the relationship between these two measures among ears with no conductive component as a benchmark, the likelihood that an ear has a conductive component can be estimated based on the deviation from this benchmark. The sensitivity and

  11. Reproducibility of the results in ultrasonic testing

    International Nuclear Information System (INIS)

    Chalaye, M.; Launay, J.P.; Thomas, A.

    1980-12-01

    This memorandum reports on the conclusions of the tests carried out in order to evaluate the reproducibility of ultrasonic tests made on welded joints. FRAMATOME have started a study to assess the dispersion of results afforded by the test line and to characterize its behaviour. The tests covered sensors and ultrasonic generators said to be identical to each other (same commercial batch) [fr

  12. Reliability engineering

    International Nuclear Information System (INIS)

    Lee, Chi Woo; Kim, Sun Jin; Lee, Seung Woo; Jeong, Sang Yeong

    1993-08-01

    This book start what is reliability? such as origin of reliability problems, definition of reliability and reliability and use of reliability. It also deals with probability and calculation of reliability, reliability function and failure rate, probability distribution of reliability, assumption of MTBF, process of probability distribution, down time, maintainability and availability, break down maintenance and preventive maintenance design of reliability, design of reliability for prediction and statistics, reliability test, reliability data and design and management of reliability.

  13. Test-Retest Reliability and Minimal Detectable Change of the D2 Test of Attention in Patients with Schizophrenia.

    Science.gov (United States)

    Lee, Posen; Lu, Wen-Shian; Liu, Chin-Hsuan; Lin, Hung-Yu; Hsieh, Ching-Lin

    2017-12-08

    The d2 Test of Attention (D2) is a commonly used measure of selective attention for patients with schizophrenia. However, its test-retest reliability and minimal detectable change (MDC) are unknown in patients with schizophrenia, limiting its utility in both clinical and research settings. The aim of the present study was to examine the test-retest reliability and MDC of the D2 in patients with schizophrenia. A rater administered the D2 on 108 patients with schizophrenia twice at a 1-month interval. Test-retest reliability was determined through the calculation of the intra-class correlation coefficient (ICC). We also carried out Bland-Altman analysis, which included a scatter plot of the differences between test and retest against their mean. Systematic biases were evaluated by use of a paired t-test. The ICCs for the D2 ranged from 0.78 to 0.94. The MDCs (MDC%) of the seven subscores were 102.3 (29.7), 19.4 (85.0), 7.2 (94.6), 21.0 (69.0), 104.0 (33.1), 105.0 (35.8), and 7.8 (47.8), which represented limited-to-acceptable random measurement error. Trends in the Bland-Altman plots of the omissions (E1), commissions (E2), and errors (E) were noted, presenting that the data had heteroscedasticity. According to the results, the D2 had good test-retest reliability, especially in the scores of TN, TN-E, and CP. For the further research, finding a way to improve the administration procedure to reduce random measurement error would be important for the E1, E2, E, and FR subscores. © The Author(s) 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Test-retest reliability and practice effects of the Wechsler Memory Scale-III.

    Science.gov (United States)

    Lo, Ada H Y; Humphreys, Michael; Byrne, Gerard J; Pachana, Nancy A

    2012-09-01

    Although serial administration of cognitive tests is increasingly common, there is a paucity of research on test-retest reliabilities and practice effects, both of which are important for evaluating changes in functioning. Reliability is generally conceptualized as involving short-lasting changes in performance. However, when repeated testing occurs over a period of years, there will be some longer lasting effects. The implications of these longer lasting effects and practice effects on reliability were examined in the context of repeated administrations of the Wechsler Memory Scale-III in 339 community-dwelling women aged 40-79 years over 2 to 7 years. The results showed that Logical Memory and Verbal Paired Associates subtests were consistently the most reliable subtests across the age cohorts. The magnitude of practice effects varied as a function of subtests and age. The largest practice effects were found in the youngest age cohort, especially on the Faces, Logical Memory, and Verbal Paired Associates subtests. ©2012 The British Psychological Society.

  15. Using Economic Experiments to Test the Effect of Reliability Pricing and Self-Sizing on the Private Provision of a Public Good Results: The Case of Constructing Water Conveyance Infrastructure to Mitigate Water Quantity and Quality Concerns in the Sacramento-San Joaquin Delta

    Science.gov (United States)

    Kaplan, J.; Howitt, R. E.; Kroll, S.

    2016-12-01

    Public financing of public projects is becoming more difficult with growing political and financial pressure to reduce the size and scope of government action. Private provision is possible but is often doomed by under-provision. If however, market-like mechanisms could be incorporated into the solicitation of funds to finance the provision of the good, because, for example, the good is supplied stochastically and is divisible, then we would expect fewer incentives to free ride and greater efficiency in providing the public good. In a controlled computer-based economic experiment, we evaluate two market-like conditions (reliability pricing allocation and self-sizing of the good) that are designed to reduce under-provision. The results suggest that financing an infrastructure project when the delivery is allocated based on reliability pricing rather than historical allocation results in significantly greater price formation efficiency and less free riding whether the project is of a fixed size determined by external policy makers or determined endogenously by the sum of private contributions. When reliability pricing and self-sizing (endogenous) mechanism are used in combination free-riding is reduced the greatest among the tested treatments. Furthermore, and as expected, self-sizing when combined with historical allocations results in the worst level of free-riding. This setting for this treatment creates an incentive to undervalue willingness to pay since very low contributions still return positive earnings as long as enough contributions are raised for a single unit. If everyone perceives everyone else is undervaluing their contribution the incentive grows stronger and we see the greatest degree of free riding among the treatments. Lastly, the results from the analysis suggested that the rebate rule may have encouraged those with willingness to pay values less than the cost of the project to feel confident when contributing more than their willingness to pay and

  16. Improving QST Reliability – More Raters, Tests or Occasions? A Multivariate Generalizability Study

    DEFF Research Database (Denmark)

    O'Neill, Søren; O'Neill, Lotte

    2015-01-01

    The reliability of quantitative sensory testing (QST) is affected by the error attributable to both test occasion and rater (examiner) as well as interactions between them. Most reliability studies only account for one source of error. The present study employed a fully-crossed, multivariate...... threshold, intensity, tolerance and modulation with mechanical, thermal and chemical stimuli. The classical test-retest and inter-rater reliability (0.19... procedures. Reliability was improved more by repeated testing on separate occasions opposed to repeated testing by different raters....

  17. [Reliability and validity of the Chinese version on Alcohol Use Disorders Identification Test].

    Science.gov (United States)

    Zhang, C; Yang, G P; Li, Z; Li, X N; Li, Y; Hu, J; Zhang, F Y; Zhang, X J

    2017-08-10

    Objective: To assess the reliability and validity of the Chinese version on Alcohol Use Disorders Identification Test (AUDIT) among medical students in China and to provide correct way of application on the recommended scales. Methods: An E-questionnaire was developed and sent to medical students in five different colleges. Students were all active volunteers to accept the testings. Cronbach's α and split-half reliability were calculated to evaluate the reliability of AUDIT while content, contract, discriminant and convergent validity were performed to measure the validity of the scales. Results: The overall Cronbach's α of AUDIT was 0.782 and the split-half reliability was 0.711. Data showed that the domain Cronbach's α and split-half reliability were 0.796 and 0.794 for hazardous alcohol use, 0.561 and 0.623 for dependence symptoms, and 0.647 and 0.640 for harmful alcohol use. Results also showed that the content validity index on the levels of items I-CVI) were from 0.83 to 1.00, the content validity index of scale level (S-CVI/UA) was 0.90, content validity index of average scale level (S-CVI/Ave) was 0.99 and the content validity ratios (CVR) were from 0.80 to 1.00. The simplified version of AUDIT supported a presupposed three-factor structure which could explain 61.175% of the total variance revealed through exploratory factor analysis. AUDIT semed to have good convergent and discriminant validity, with the success rate of calibration experiment as 100%. Conclusion: AUDIT showed good reliability and validity among medical students in China thus worth for promotion on its use.

  18. Reliability, construct and discriminative validity of clinical testing in subjects with and without chronic neck pain

    DEFF Research Database (Denmark)

    Jørgensen, René; Ris Hansen, Inge; Falla, Deborah

    2014-01-01

    -retest reliability in people with and without chronic neck pain. Moreover, construct and between-group discriminative validity of the tests were examined. METHODS: Twenty-one participants with chronic neck pain and 21 asymptomatic participants were included. Intra- and inter-reliability were evaluated for the Cranio-Cervical...... Flexion Test (CCFT), Range of Movement (ROM), Joint Position Error (JPE), Gaze Stability (GS), Smooth Pursuit Neck Torsion Test (SPNTT), and neuromuscular control of the Deep Cervical Extensors (DCE). Test-retest reliability was assessed for Postural Control (SWAY) and Pressure Pain Threshold (PPT) over......BACKGROUND: The reliability of clinical tests for the cervical spine has not been adequately evaluated. Six cervical clinical tests, which are low cost and easy to perform in clinical settings, were tested for intra- and inter-examiner reliability, and two performance tests were assessed for test...

  19. Structural Testing of the Blade Reliability Collaborative Effect of Defect Wind Turbine Blades

    Energy Technology Data Exchange (ETDEWEB)

    Desmond, M. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hughes, S. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Paquette, J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-06-08

    Two 8.3-meter (m) wind turbine blades intentionally constructed with manufacturing flaws were tested to failure at the National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL) south of Boulder, Colorado. Two blades were tested; one blade was manufactured with a fiberglass spar cap and the second blade was manufactured with a carbon fiber spar cap. Test loading primarily consisted of flap fatigue loading of the blades, with one quasi-static ultimate load case applied to the carbon fiber spar cap blade. Results of the test program were intended to provide the full-scale test data needed for validation of model and coupon test results of the effect of defects in wind turbine blade composite materials. Testing was part of the Blade Reliability Collaborative (BRC) led by Sandia National Laboratories (SNL). The BRC seeks to develop a deeper understanding of the causes of unexpected blade failures (Paquette 2012), and to develop methods to enable blades to survive to their expected operational lifetime. Recent work in the BRC includes examining and characterizing flaws and defects known to exist in wind turbine blades from manufacturing processes (Riddle et al. 2011). Recent results from reliability databases show that wind turbine rotor blades continue to be a leading contributor to turbine downtime (Paquette 2012).

  20. Reliability Verification of DBE Environment Simulation Test Facility by using Statistics Method

    International Nuclear Information System (INIS)

    Jang, Kyung Nam; Kim, Jong Soeg; Jeong, Sun Chul; Kyung Heum

    2011-01-01

    In the nuclear power plant, all the safety-related equipment including cables under the harsh environment should perform the equipment qualification (EQ) according to the IEEE std 323. There are three types of qualification methods including type testing, operating experience and analysis. In order to environmentally qualify the safety-related equipment using type testing method, not analysis or operation experience method, the representative sample of equipment, including interfaces, should be subjected to a series of tests. Among these tests, Design Basis Events (DBE) environment simulating test is the most important test. DBE simulation test is performed in DBE simulation test chamber according to the postulated DBE conditions including specified high-energy line break (HELB), loss of coolant accident (LOCA), main steam line break (MSLB) and etc, after thermal and radiation aging. Because most DBE conditions have 100% humidity condition, in order to trace temperature and pressure of DBE condition, high temperature steam should be used. During DBE simulation test, if high temperature steam under high pressure inject to the DBE test chamber, the temperature and pressure in test chamber rapidly increase over the target temperature. Therefore, the temperature and pressure in test chamber continue fluctuating during the DBE simulation test to meet target temperature and pressure. We should ensure fairness and accuracy of test result by confirming the performance of DBE environment simulation test facility. In this paper, in order to verify reliability of DBE environment simulation test facility, statistics method is used

  1. Test-retest reliability of the driving habits questionnaire in older self-driving adults.

    Science.gov (United States)

    Song, Chiang-Soon; Chun, Byung-Yoon; Chung, Hyun-Sook

    2015-11-01

    [Purpose] The purpose of this study was to investigate the test-retest reliability of the Driving Habits Questionnaire in community-dwelling older self-drivers. [Subjects and Methods] Seventy-four participants were recruited by convenience sampling from local rehabilitation centers. This was a cross-sectional study design that used two clinical measures: the Driving Habits Questionnaire and Mini-mental State Examination. To examine the test-retest reliability of the Driving Habits Questionnaire, the clinical tool was measured twice, five days apart. [Results] The Driving Habits Questionnaire showed good reliability for older community-dwelling self-drivers. The Cronbach's alpha coefficients for the four domains of dependence (0.572), difficulty (0.871), crashes and citations (0.689), and driving space (0.961) of the Driving Habits Questionnaire indicated good or high internal consistency. Driving difficulty correlated significantly with self-reported crashes and citations and driving space. [Conclusion] The results of this study suggest that the Driving Habits Questionnaire is a reliable measure of self-reported interview-based driving behavior in the community-dwelling elderly.

  2. Test-retest reliability of the Clinical Learning Environment, Supervision and Nurse Teacher (CLES + T) scale.

    Science.gov (United States)

    Gustafsson, Margareta; Blomberg, Karin; Holmefur, Marie

    2015-07-01

    The Clinical Learning Environment, Supervision and Nurse Teacher (CLES + T) scale evaluates the student nurses' perception of the learning environment and supervision within the clinical placement. It has never been tested in a replication study. The aim of the present study was to evaluate the test-retest reliability of the CLES + T scale. The CLES + T scale was administered twice to a group of 42 student nurses, with a one-week interval. Test-retest reliability was determined by calculations of Intraclass Correlation Coefficients (ICCs) and weighted Kappa coefficients. Standard Error of Measurements (SEM) and Smallest Detectable Difference (SDD) determined the precision of individual scores. Bland-Altman plots were created for analyses of systematic differences between the test occasions. The results of the study showed that the stability over time was good to excellent (ICC 0.88-0.96) in the sub-dimensions "Supervisory relationship", "Pedagogical atmosphere on the ward" and "Role of the nurse teacher". Measurements of "Premises of nursing on the ward" and "Leadership style of the manager" had lower but still acceptable stability (ICC 0.70-0.75). No systematic differences occurred between the test occasions. This study supports the usefulness of the CLES + T scale as a reliable measure of the student nurses' perception of the learning environment within the clinical placement at a hospital. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Users manual on database of the Piping Reliability Proving Tests at the Japan Atomic Energy Research Institute

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    Japan Atomic Energy Research Institute(JAERI) conducted Piping Reliability Proving Tests from 1975 to 1992 based upon the contracts between JAERI and Science and Technology Agency of Japan under the auspices of the special account law for electric power development promotion. The purposes of those tests are to prove the structural reliability of the primary cooling piping constituting a part of the pressure boundary in the water reactor power plants. The tests with large experimental facilities had ended already in 1990. After that piping reliability analysis by the probabilistic method followed until 1992. This report describes the users manual on databases about the test results using the large experimental facilities. Objectives of the piping reliability proving tests are to prove that the primary piping of the water reactor (1) be reliable throughout the service period, (2) have no possibility of rupture, (3) bring no detrimental influence on the surrounding instrumentations or equipments near the break location. The research activities using large scale piping test facilities are described. The present report does the database about the test results pairing the former report. With these two reports, all the feature of Piping Reliability Proving Tests is made clear. Briefings of the tests are described also written in Japanese or English. (author)

  4. Frontiers of reliability

    CERN Document Server

    Basu, Asit P; Basu, Sujit K

    1998-01-01

    This volume presents recent results in reliability theory by leading experts in the world. It will prove valuable for researchers, and users of reliability theory. It consists of refereed invited papers on a broad spectrum of topics in reliability. The subjects covered include Bayesian reliability, Bayesian reliability modeling, confounding in a series system, DF tests, Edgeworth approximation to reliability, estimation under random censoring, fault tree reduction for reliability, inference about changes in hazard rates, information theory and reliability, mixture experiment, mixture of Weibul

  5. The timed "up and go" test : Reliability and validity in persons with unilateral lower limb amputation

    NARCIS (Netherlands)

    Schoppen, Tanneke; Boonstra, Antje; Groothoff, JW; de Vries, J; Goeken, LNH; Eisma, Willem

    Objective: To determine the interrater and interrater reliability and the validity of the Timed "up and go" test as a measure for physical mobility in elderly patients with an amputation of the lower extremity. Design: To test interrater reliability, the test was performed for two observers at

  6. Validity and reliability of tests determining performance-related components of wheelchair basketball

    NARCIS (Netherlands)

    de Groot, Sonja; Balvers, Inge J.M.; Kouwenhoven, Sanne M.; Janssen, Thomas W.J.

    The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players'

  7. Validity and reliability of tests determining performance-related components of wheelchair basketball

    NARCIS (Netherlands)

    De Groot, Sonja; Balvers, Inge J. M.; Kouwenhoven, Sanne M.; Janssen, Thomas W. J.

    2012-01-01

    The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players'

  8. An Integrated Approach to Establish Validity and Reliability of Reading Tests

    Science.gov (United States)

    Razi, Salim

    2012-01-01

    This study presents the processes of developing and establishing reliability and validity of a reading test by administering an integrative approach as conventional reliability and validity measures superficially reveals the difficulty of a reading test. In this respect, analysing vocabulary frequency of the test is regarded as a more eligible way…

  9. Diagnosis of carpal tunnel syndrome: interobserver reliability of the blinded scratch-collapse test

    NARCIS (Netherlands)

    Blok, Robin D.; Becker, Stéphanie J. E.; Ring, David C.

    2014-01-01

    The reliability of the scratch-collapse test for diagnosis of carpal tunnel syndrome (CTS) has not been tested by independent investigators. This study measured the reliability of the scratch-collapse test comparing the treating hand surgeon and blinded evaluators. We performed a prospective

  10. Validity and Reliability Testing of an e-learning Questionnaire for Chemistry Instruction

    Science.gov (United States)

    Guspatni, G.; Kurniawati, Y.

    2018-04-01

    The aim of this paper is to examine validity and reliability of a questionnaire used to evaluate e-learning implementation in chemistry instruction. 48 questionnaires were filled in by students who had studied chemistry through e-learning system. The questionnaire consisted of 20 indicators evaluating students’ perception on using e-learning. Parametric testing was done as data were assumed to follow normal distribution. Item validity of the questionnaire was examined through item-total correlation using Pearson’s formula while its reliability was assessed with Cronbach’s alpha formula. Moreover, convergent validity was assessed to see whether indicators building a factor had theoretically the same underlying construct. The result of validity testing revealed 19 valid indicators while the result of reliability testing revealed Cronbach’s alpha value of .886. The result of factor analysis showed that questionnaire consisted of five factors, and each of them had indicators building the same construct. This article shows the importance of factor analysis to get a construct valid questionnaire before it is used as research instrument.

  11. Utilization and reliability of nondestructive testing in ordnance

    International Nuclear Information System (INIS)

    Maranhao, M.; Alves, L.E.G.

    1983-01-01

    Information about nondestructive testing used in ordnance are presented. For propellants and breaking load ultrasonic testing and X-ray are used. For skyrocket propellants the X-ray is used to test the continuity of the explosive mass and the burn inhibiting agent. For rupture explosive, the X-ray is used to test the continuity of explosive mass. (E.G.) [pt

  12. Test-Retest Reliability of Diffusion Tensor Imaging in Huntington's Disease.

    Science.gov (United States)

    Cole, James H; Farmer, Ruth E; Rees, Elin M; Johnson, Hans J; Frost, Chris; Scahill, Rachael I; Hobbs, Nicola Z

    2014-03-21

    Diffusion tensor imaging (DTI) has shown microstructural abnormalities in patients with Huntington's Disease (HD) and work is underway to characterise how these abnormalities change with disease progression. Using methods that will be applied in longitudinal research, we sought to establish the reliability of DTI in early HD patients and controls. Test-retest reliability, quantified using the intraclass correlation coefficient (ICC), was assessed using region-of-interest (ROI)-based white matter atlas and voxelwise approaches on repeat scan data from 22 participants (10 early HD, 12 controls). T1 data was used to generate further ROIs for analysis in a reduced sample of 18 participants. The results suggest that fractional anisotropy (FA) and other diffusivity metrics are generally highly reliable, with ICCs indicating considerably lower within-subject compared to between-subject variability in both HD patients and controls. Where ICC was low, particularly for the diffusivity measures in the caudate and putamen, this was partly influenced by outliers. The analysis suggests that the specific DTI methods used here are appropriate for cross-sectional research in HD, and give confidence that they can also be applied longitudinally, although this requires further investigation. An important caveat for DTI studies is that test-retest reliability may not be evenly distributed throughout the brain whereby highly anisotropic white matter regions tended to show lower relative within-subject variability than other white or grey matter regions.

  13. Intertester reliability of clinical shoulder instability and laxity tests in subjects with and without self-reported shoulder problems.

    Science.gov (United States)

    Eshoj, Henrik; Ingwersen, Kim Gordon; Larsen, Camilla Marie; Kjaer, Birgitte Hougs; Juul-Kristensen, Birgit

    2018-03-03

    First, to investigate the intertester reliability of clinical shoulder instability and laxity tests, and second, to describe the mutual dependency of each test evaluated by each tester for identifying self-reported shoulder instability and laxity. A standardised protocol for conducting reliability studies was used to test the intertester reliability of the six clinical shoulder instability and laxity tests: apprehension, relocation, surprise, load-and-shift, sulcus sign and Gagey. Cohen's kappa (κ) with 95% CIs besides prevalence-adjusted and bias-adjusted kappa (PABAK), accounting for insufficient prevalence and bias, were computed to establish the intertester reliability and mutual dependency. Forty individuals (13 with self-reported shoulder instability and laxity-related shoulder problems and 27 normal shoulder individuals) aged 18-60 were included. Fair (relocation), moderate (load-and-shift, sulcus sign) and substantial (apprehension, surprise, Gagey) intertester reliability were observed across tests (κ 0.39-0.73; 95% CI 0.00 to 1.00). PABAK improved reliability across tests, resulting in substantial to almost perfect intertester reliability for the apprehension, surprise, load-and-shift and Gagey tests (κ 0.65-0.90). Mutual dependencies between each test and self-reported shoulder problem showed apprehension, relocation and surprise to be the most often used tests to characterise self-reported shoulder instability and laxity conditions. Four tests (apprehension, surprise, load-and-shift and Gagey) out of six were considered intertester reliable for clinical use, while relocation and sulcus sign tests need further standardisation before acceptable evidence. Furthermore, the validity of the tests for shoulder instability and laxity needs to be studied. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Reliability demonstration methodology for products with Gamma Process by optimal accelerated degradation testing

    International Nuclear Information System (INIS)

    Zhang, Chunhua; Lu, Xiang; Tan, Yuanyuan; Wang, Yashun

    2015-01-01

    For products with high reliability and long lifetime, accelerated degradation testing (ADT) may be adopted during product development phase to verify whether its reliability satisfies the predetermined level within feasible test duration. The actual degradation from engineering is usually a strictly monotonic process, such as fatigue crack growth, wear, and erosion. However, the method for reliability demonstration by ADT with monotonic degradation process has not been investigated so far. This paper proposes a reliability demonstration methodology by ADT for this kind of product. We first apply Gamma process to describe the monotonic degradation. Next, we present a reliability demonstration method by converting the required reliability level into allowable cumulative degradation in ADT and comparing the actual accumulative degradation with the allowable level. Further, we suggest an analytical optimal ADT design method for more efficient reliability demonstration by minimizing the asymptotic variance of decision variable in reliability demonstration under the constraints of sample size, test duration, test cost, and predetermined decision risks. The method is validated and illustrated with example on reliability demonstration of alloy product, and is applied to demonstrate the wear reliability within long service duration of spherical plain bearing in the end. - Highlights: • We present a reliability demonstration method by ADT for products with monotonic degradation process, which may be applied to verify reliability with long service life for products with monotonic degradation process within feasible test duration. • We suggest an analytical optimal ADT design method for more efficient reliability demonstration, which differs from the existed optimal ADT design for more accurate reliability estimation by different objective function and different constraints. • The methods are applied to demonstrate the wear reliability within long service duration of

  15. Intra- and inter-rater reliability of movement and palpation tests in patients with neck pain: A systematic review.

    Science.gov (United States)

    Jonsson, Anders; Rasmussen-Barr, Eva

    2018-03-01

    Neck pain is common and often becomes chronic. Various clinical tests of the cervical spine are used to direct and evaluate treatment. This systematic review aimed to identify studies examining the intra- and/or interrater reliability of tests used in clinical examination of patients with neck pain. A database search up to April 2016 was conducted in PubMed, CINAHL, and AMED. The Quality Appraisal of Reliability Studies Checklist (QAREL) was used to assess risk of bias. Eleven studies were included, comprising tests of active and passive movement and pain evaluating participants with ongoing neck pain. One study was assessed with a low risk of bias, three with medium risk, while the rest were assessed with high risk of bias. The results showed differing reliabilities for the included tests ranging from poor to almost perfect. In conclusion, active movement and pain for pain or mobility overall presented acceptable to very good reliability (Kappa >0.40); while passive intervertebral tests had lower Kappa values, suggesting poor reliability. It may be a coincidence that the studies indicating very good reliability tended to be of higher quality (low to moderate risk of bias), while studies finding poor reliability tended to be of lower quality (high risk of bias). Regardless, the current recommendation from this review would suggest the clinical use of tests with acceptable reliability and avoiding the use of tests that have been shown to not be reliable. Finally, it is critical that all future reliability studies are of higher quality with low risk of bias.

  16. CERN Technical training 2008 - Learning for the LHC: Special Workshop demonstrating reliability with accelerated testing

    CERN Multimedia

    2008-01-01

    Larry Edson’s workshop will show examples of quantitative reliability predictions based upon accelerated testing and demonstrates that reliability testing during the prototyping phase will help ascertain product shortcomings. When these weak points are addressed and the redesigned product is re-tested, the reliability of that product will become much higher. These methodologies successfully used in industry might be exceedingly useful also for component development in particle physics where reliability is of utmost importance. This training will provide participants with the skills necessary to demonstrate reliability requirements using accelerated testing methods. The workshop will focus on accelerated test design that employs increased stress levels. This approach has the advantage of reducing test time, sample size and test facility resources. The methodologies taught are applicable to all types of stresses, spanning the electro...

  17. CERN Technical training 2008 - Learning for the LHC: Special Workshop demonstrating reliability with accelerated testing

    CERN Multimedia

    2008-01-01

    Larry Edson’s workshop will show examples of quantitative reliability predictions based upon accelerated testing and demonstrate that reliability testing during the prototyping phase will help ascertain product shortcomings. When these weak points are addressed and the redesigned product is re-tested, the reliability of that product will become much higher. These methodologies successfully used in industry might be exceedingly useful also for component development in particle physics where reliability is of the utmost importance. This training will provide participants with the skills necessary to demonstrate reliability requirements using accelerated testing methods. The workshop will focus on accelerated test design that employs increased stress levels. This approach has the advantage of reducing test time, sample size and test facility resources. The methodologies taught are applicable to all types of stresses, spanning the elec...

  18. CERN Technical training 2008 - Learning for the LHC: Special workshop demonstrating reliability with accelerated testing

    CERN Multimedia

    2008-01-01

    Larry Edson’s workshop will show examples of quantitative reliability predictions based upon accelerated testing and demonstrate that reliability testing during the prototyping phase will help ascertain product shortcomings. When these weak points are addressed and the redesigned product is re-tested, the reliability of that product will become much higher. These methodologies successfully used in industry might be exceedingly useful also for component development in particle physics where reliability is of the utmost importance. This training will provide participants with the skills necessary to demonstrate reliability requirements using accelerated testing methods. The workshop will focus on accelerated test design that employs increased stress levels. This approach has the advantage of reducing test time, sample size and test facility resources. The methodologies taught are applicable to all types of stresses, spanning the elec...

  19. Reliability of the Balance Evaluation Systems Test (BESTest) and BESTest sections for adults with hemiparesis

    Science.gov (United States)

    Rodrigues, Letícia C.; Marques, Aline P.; Barros, Paula B.; Michaelsen, Stella M.

    2014-01-01

    BACKGROUND: The Balance Evaluation Systems Test (BESTest) was recently created to allow the development of treatments according to the specific balance system affected in each patient. The Brazilian version of the BESTest has not been specifically tested after stroke. OBJECTIVE: To evaluate the intra- and inter-rater reliability and concurrent and convergent validity of the total score of the BESTest and BESTest sections for adults with hemiparesis after stroke. METHOD: The study included 16 subjects (61.1±7.5 years) with chronic hemiparesis (54.5±43.5 months after stroke). The BESTest was administered by two raters in the same week and one of the raters repeated the test after a one-week interval. Intraclass correlation coefficient (ICC) was calculated to assess intra- and interrater reliability. Concurrent validity with the Berg Balance Scale (BBS) and convergent validity with the Activities-specific Balance Confidence scale (ABC-Brazil) were assessed using Pearson's correlation coefficient. RESULTS: Both the BESTest total score (ICC=0.98) and the BESTest sections (ICC between 0.85 and 0.96) have excellent intrarater reliability. Interrater reliability for the total score was excellent (ICC=0.93) and, for the sections, it ranged between 0.71 and 0.94. The correlation coefficient between the BESTest and the BBS and ABC-Brazil were 0.78 and 0.59, respectively. CONCLUSIONS: The Brazilian version of the BESTest demonstrated adequate reliability when measured by sections and could identify what balance system was affected in patients after stroke. Concurrent validity was excellent with the BBS total score and good to excellent with the sections. The total scores but not the sections present adequate convergent validity with the ABC-Brazil. However, other psychometric properties should be further investigated. PMID:25003281

  20. Intra-rater reliability of cervical sensory motor function and cervical reconstruction test in healthy subjects

    Directory of Open Access Journals (Sweden)

    Hatamvand S

    2016-07-01

    Full Text Available Impairment of cervicocephalic and head joint position sense has an important role in the recurrent and chronic of cervicocephalic pain. The various tools are suggested for evaluating the cervicocephalic joint position sense. Although reconstruction of cervical angle is a clinical criterion for measuring the cervicocephalic proprioception, the reliability of this method has not been completely accepted. The purpose of this study was to evaluate intra-rater reliability of cervical sensory motor function and cervical reconstruction test in healthy subjects. twenty four healthy subjects (25.70±6.08 y through simple non-probability sampling participated in this single-group repeatedmeasures reliability study. Participants were asked to relocate the neck, as accurately as possible, after full active cervical flexion, extension and rotation to the left and right sides. Five trials were performed for each movement. Laser pointer was used in head of patient. The distance between zero spot and joint position which patient had been reconstructed, was measured by centimeter. Intra-class correlation Coefficient (ICCs and Pearson's correlation coefficient test was used to determine intra-rater reliability of variables. The results showed that intra-class correlation Coefficient (ICCs values with 95% confidence interval (CI and the standard error of the measurement (SEM were good to excellent agreement for a single investigator between measurement occasions. Intra-class correlation Coefficient (ICCs values were obtained for flexion movement (ICCs:0.75, good, extension movement (ICCs:0.81, very good, right rotation (ICCs:0.64, good and left rotation (ICCs:0.64, good. The cervicocephalic relocation test to neutral head position by laser pointer is a reliable method to measure cervical sensory motor function. Therefore, it can be used for evaluating cervicocephalic proprioception of patient with cervicocephalic pain.

  1. Validity and Reliability of the Clock Drawing Test in Older People

    Directory of Open Access Journals (Sweden)

    Massoumeh Sadeghipour Roodsari

    2013-07-01

    Full Text Available Objectives: Early diagnosis of cognitive disorders in order to initiate new efficient treatments in time is an important task which cannot be fulfilled without proper cognitive screening tools. The Clock Drawing Test (CDT is a simple inexpensive cognitive screening tool which can be used in primary care settings delivering health services to older people. The aim of this study was to assess validity and reliability of the CDT in Iranian older population. Methods & Materials: In this study the CDT and Mini Mental State Examination (MMSE were concurrently performed on 74 literate participants aged 60 and over. Participants were recruited from the clients of Iran Alzheimer’s Association (dementia patients and non-demented clients, including other patients or care givers during a 5 month period. The CDT was performed by two trained raters using Shulman’s six points scoring method. Using SPSS version 20, reliability was assessed measuring kappa statistics as well as ICC. Concurrent validity between CDT and MMSE were statistically analyzed by spearman’s rank correlation coefficient. Results: Mean age of the participants was 72 years in a range of 60 to 90 years with equal numbers 0f male and female participants. Kappa statistics for test retest reliability was 0.554 (P<0.001. ICC for inter rater reliability was 0.964 (P<0.001. Spearman’s rank correlation coefficient for MMSE and CDT scores was 0.782, statistically significant at P<0.001. Conclusion: CDT is a valid and reliable test in literate older people that can be used as a cognitive screening tool in Iranian older population.

  2. Human and organisational factors in the reliability of non-destructive testing (NOT)

    International Nuclear Information System (INIS)

    Norros, L.

    1998-01-01

    Non-destructive testing used in in-service inspections can be seen as a complicated activity system including three mutually related sub-activities: (1) definition of inspection programs and necessary resources, (2) carrying out diagnostic inspections, and (3) interpretation of the results from the view of plant safety and corrective measures. Various studies to investigate and measure the NDT performance have produced disappointing result. No clear correlations between single human factors and performance have been identified even though general agreement exists concerning the significance of human factors to the reliability of testing. Another incentive for our studies has been to test and evaluate the applicability of the international results in the Finnish circumstances. Three successive studies have thus been carried out on the human and organisational factors in non-destructive testing. (author)

  3. Test-retest reliability and task order effects of emotional cognitive tests in healthy subjects.

    Science.gov (United States)

    Adams, Thomas; Pounder, Zoe; Preston, Sally; Hanson, Andy; Gallagher, Peter; Harmer, Catherine J; McAllister-Williams, R Hamish

    2016-11-01

    Little is known of the retest reliability of emotional cognitive tasks or the impact of using different tasks employing similar emotional stimuli within a battery. We investigated this in healthy subjects. We found improved overall performance in an emotional attentional blink task (EABT) with repeat testing at one hour and one week compared to baseline, but the impact of an emotional stimulus on performance was unchanged. Similarly, performance on a facial expression recognition task (FERT) was better one week after a baseline test, though the relative effect of specific emotions was unaltered. There was no effect of repeat testing on an emotional word categorising, recall and recognition task. We found no difference in performance in the FERT and EABT irrespective of task order. We concluded that it is possible to use emotional cognitive tasks in longitudinal studies and combine tasks using emotional facial stimuli in a single battery.

  4. Impact of relationships between test and training animals and among training animals on reliability of genomic prediction.

    Science.gov (United States)

    Wu, X; Lund, M S; Sun, D; Zhang, Q; Su, G

    2015-10-01

    One of the factors affecting the reliability of genomic prediction is the relationship among the animals of interest. This study investigated the reliability of genomic prediction in various scenarios with regard to the relationship between test and training animals, and among animals within the training data set. Different training data sets were generated from EuroGenomics data and a group of Nordic Holstein bulls (born in 2005 and afterwards) as a common test data set. Genomic breeding values were predicted using a genomic best linear unbiased prediction model and a Bayesian mixture model. The results showed that a closer relationship between test and training animals led to a higher reliability of genomic predictions for the test animals, while a closer relationship among training animals resulted in a lower reliability. In addition, the Bayesian mixture model in general led to a slightly higher reliability of genomic prediction, especially for the scenario of distant relationships between training and test animals. Therefore, to prevent a decrease in reliability, constant updates of the training population with animals from more recent generations are required. Moreover, a training population consisting of less-related animals is favourable for reliability of genomic prediction. © 2015 Blackwell Verlag GmbH.

  5. Supercritical CO2 test loop operation and first test results

    International Nuclear Information System (INIS)

    Wright, Steven A.; Pickard, Paul S.

    2009-01-01

    The DOE Office of Nuclear Energy is investigating advanced Brayton cycles for use with next generation nuclear power plants. The focus of this work is on the supercritical CO 2 Brayton cycle which has the potential for high efficiency, and for reduced capital costs due to very compact turbomachinery. Sandia has fabricated and is operating a supercritical CO 2 (S-CO 2 ) test loop to investigate the key technology issues associated with this cycle. This loop is part of a multi-year phased development program to develop a megawatt (MW) class closed S-CO 2 Brayton cycle to demonstrate the applicability of this cycle for DOE Gen-IV program. The current loop has been configured as both a compression loop and as simple heated but unrecuperated Brayton cycle. A second split-flow or re-compression Brayton cycle is currently under development that will use approximately 1 MW of heat to run the Brayton cycle. Early configurations of this split-flow Brayton cycle will be operational later this fiscal year. The key issues for this cycle include the fundamental issues of compressor fluid performance and system control near the critical point, but also the supporting technology issues of bearings, sealing technologies, and rotor windage losses which are also essential to achieving efficiency and cost objectives. These tests are providing the first measurements and information on these key supercritical CO 2 power conversion systems questions. Important data for all these issues has been obtained. This report presents the major results of the testing by showing and comparing the measured compressor performance map with the predicted performance. The compression loop uses a ∼50 kWe motor driven compressor to spin a 37 mm OD compressor at design speeds up to 75,000 rpm with a pressure ratio of 1.8 and a flow rate of 3.53 kg/s for a compressor inlet condition of 305.3 K and 7690 kPa. The most recent configuration of this loop has added a small turbine and 260 kW of heater power is

  6. Validity and reliability of the 10-m walk test and the 6-min walk test in spinal cord injury patients.

    Science.gov (United States)

    Scivoletto, G; Tamburella, F; Laurenza, L; Foti, C; Ditunno, J F; Molinari, M

    2011-06-01

    The 10-m walk test (10MWT) and the 6-min walk test (6MWT) have been recommended for assessment of walking in spinal cord injury (SCI) patients. The study was designed on test-retest analysis of the 10MWT and 6MWT. The objective of this study was to assess validity/reliability of different methods of performing the tests. The study was set at an SCI unit of a rehabilitation hospital. A total of 37 patients; whose median age was 58.5 years (interquartile range 40-66, full range 19-77); median time since onset of SCI was 24 months (interquartile range 16.25-70.5, full range 6-109). Non-traumatic etiology in 20 out of 37 patients; level: 12C, 14T and 11L; American Spinal Injury Association Impairment Scale grade: 35D/2C. Assessment with the 10MWT (with or without dynamic start) and the 6MWT (short or long track) by two blinded raters to evaluate inter/intra-rater reliabilities. The 10MWT was performed in a median of 19 s (25th-75th interquartile range 13-28) with the dynamic start and of 18.4 s (25th-75th interquartile range 12.6-29.9) with the static start (P=0.092). The correlation between the results of the two methods was between 0.98 and 0.99. The inter- and intra-rater reliabilities were between 0.95 and 0.99 for both the methods. The 6MWT showed significant differences according to the track length: patients walked a median of 226.7 m (25th-75th interquartile range 123.2-319) on the longer track and of 187.6 m (25th-75th interquartile range 69.7-240.6) on the short one (P<0.001). The correlation between the results of the two methods was between 0.91 and 0.93. The inter- and intra-rater reliabilities were between 0.98 and 0.99. The 10MWT shows high inter/intra-rater reliability and shows comparable results with both dynamic and static start. The different testing conditions of the 6MWT (track/turns) results in significant differences that need standardization for use in future trials.

  7. A reliable unipedal stance test for the assessment of balance using a force platform.

    Science.gov (United States)

    Ponce-González, J G; Sanchis-Moysi, J; González-Henriquez, J J; Arteaga-Ortiz, R; Calbet, J A L; Dorado, C

    2014-02-01

    The aim was to develop a unipedal stance test for the assessment of balance using a force platform. A single-leg balance test was conducted in 23 students (mean ± SD) age: 23 ± 3 years) in a standard position limiting the movement of the arms and non-supporting leg. Six attempts, with both the jumping (JL) and the contralateral leg (CL), were performed under 3 conditions: 1) eyes opened; 2) eyes closed; 3) eyes opened and executing a precision task. The same protocol was repeated two-week apart. The mean and the best result of the six attempts performed each day were taken as representative of balance. The speed of the centre of pressure (CP-Speed) showed excellent reliability for the "best result" analysis in all tests (ICCs 0.87-0.97), except in the test with the eyes closed performed on the CL (ICCtest. The single-leg stance balance test proposed is a reliable method to assess balance, especially when performed in a static position, with the eyes opened and using the best result of six attempts as reference, independently of the stance leg.

  8. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan

    Directory of Open Access Journals (Sweden)

    Moore AL

    2018-02-01

    Full Text Available Amy Lawson Moore, Terissa M Miller Gibson Institute of Cognitive Research, Colorado Springs, CO, USA Purpose: The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills.Methods: This study included 2,737 participants aged 5–85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test–retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement.Results: Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test–retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93.Conclusion: The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan. Keywords: testing, cognitive skills, memory, processing speed, visual processing, auditory processing

  9. Results of steel containment vessel model test

    International Nuclear Information System (INIS)

    Luk, V.K.; Ludwigsen, J.S.; Hessheimer, M.F.; Komine, Kuniaki; Matsumoto, Tomoyuki; Costello, J.F.

    1998-05-01

    A series of static overpressurization tests of scale models of nuclear containment structures is being conducted by Sandia National Laboratories for the Nuclear Power Engineering Corporation of Japan and the US Nuclear Regulatory Commission. Two tests are being conducted: (1) a test of a model of a steel containment vessel (SCV) and (2) a test of a model of a prestressed concrete containment vessel (PCCV). This paper summarizes the conduct of the high pressure pneumatic test of the SCV model and the results of that test. Results of this test are summarized and are compared with pretest predictions performed by the sponsoring organizations and others who participated in a blind pretest prediction effort. Questions raised by this comparison are identified and plans for posttest analysis are discussed

  10. The PANDA facility and first test results

    International Nuclear Information System (INIS)

    Dreier, J.; Huggenberger, M.; Aubert, C.; Bandurski, T.; Fischer, O.; Healzer, J.; Lomperski, S.; Strassberger, H.J.; Varadi, G.; Yadigaroglu, G.

    1996-01-01

    The PANDA test facility at the Paul Scherrer Institute is used to study the long-term performance of the Simplified Boiling Water Reactor's passive containment cooling system. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensable gases in the system. The facility is in 1:1 vertical scale and 1:25 scale for volume, power etc. Extensive facility characterization tests and steady-state passive containment condenser performance tests are presented. The results of the base case test of a series of transient system behaviour tests are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the Simplified Boiling Water Reactor's containment is likely to be favorably responsive and highly robust to changes in the thermal transport patterns. (orig.) [de

  11. Multi Directional Repeated Sprint Is a Valid and Reliable Test for Assessment of Junior Handball Players

    Directory of Open Access Journals (Sweden)

    Amin Daneshfar

    2018-04-01

    Full Text Available The aim of the present study was to examine the validity and reliability of a 10 × (6 × 5 m multi-directional repeated sprint ability test (RSM in elite young team handball (TH players. Participants were members of the Iranian national team (n = 20, age 16.4 ± 0.7 years, weight 82.5 ± 5.5 kg, height 184.8 ± 4.6 cm, body fat 15.4 ± 4.3%. The validity of RSM was tested against a 10 × (15 + 15 m repeated sprint ability test (RSA, Yo-Yo Intermittent Recovery test Level 1 (Yo-Yo IR1, squat jump (SJ and countermovement jump (CMJ. To test the reliability of RSM, the participants repeated the testing sessions of RSM and RSA 1 week later. Both RSA and RSM tests showed good to excellent reliability of the total time (TT, best time (BT, and weakest time (WT. The results of the correlation analysis showed significant inverse correlations between maximum aerobic capacity and TT in RSA (r = −0.57, p ≤ 0.05 and RSM (r = −0.76, p ≤ 0.01. There was also a significant inverse correlation between maximum aerobic capacity with fatigue index (FI in RSA test (r = −0.64, p ≤ 0.01 and in RSM test (r = −0.53, p ≤ 0.05. BT, WT, and TT of RSA was largely-to-very largely correlated with BT (r = 0.58, p ≤ 0.01, WT (r = 0.62, p ≤ 0.01, and TT (r = 0.65, p ≤ 0.01 of RSM. BT in RSM was also correlated with FI in RSM (r = 0.88, p ≤ 0.01. In conclusion, based on the findings of the current study, the recently developed RSM test is a valid and reliable test and should be utilized for assessment of repeated sprint ability in handball players.

  12. Multi Directional Repeated Sprint Is a Valid and Reliable Test for Assessment of Junior Handball Players

    Science.gov (United States)

    Daneshfar, Amin; Gahreman, Daniel E.; Koozehchian, Majid S.; Amani Shalamzari, Sadegh; Hassanzadeh Sablouei, Mozhgan; Rosemann, Thomas; Knechtle, Beat; Nikolaidis, Pantelis T.

    2018-01-01

    The aim of the present study was to examine the validity and reliability of a 10 × (6 × 5 m) multi-directional repeated sprint ability test (RSM) in elite young team handball (TH) players. Participants were members of the Iranian national team (n = 20, age 16.4 ± 0.7 years, weight 82.5 ± 5.5 kg, height 184.8 ± 4.6 cm, body fat 15.4 ± 4.3%). The validity of RSM was tested against a 10 × (15 + 15 m) repeated sprint ability test (RSA), Yo-Yo Intermittent Recovery test Level 1 (Yo-Yo IR1), squat jump (SJ) and countermovement jump (CMJ). To test the reliability of RSM, the participants repeated the testing sessions of RSM and RSA 1 week later. Both RSA and RSM tests showed good to excellent reliability of the total time (TT), best time (BT), and weakest time (WT). The results of the correlation analysis showed significant inverse correlations between maximum aerobic capacity and TT in RSA (r = −0.57, p ≤ 0.05) and RSM (r = −0.76, p ≤ 0.01). There was also a significant inverse correlation between maximum aerobic capacity with fatigue index (FI) in RSA test (r = −0.64, p ≤ 0.01) and in RSM test (r = −0.53, p ≤ 0.05). BT, WT, and TT of RSA was largely-to-very largely correlated with BT (r = 0.58, p ≤ 0.01), WT (r = 0.62, p ≤ 0.01), and TT (r = 0.65, p ≤ 0.01) of RSM. BT in RSM was also correlated with FI in RSM (r = 0.88, p ≤ 0.01). In conclusion, based on the findings of the current study, the recently developed RSM test is a valid and reliable test and should be utilized for assessment of repeated sprint ability in handball players. PMID:29670536

  13. Development of a valid and reliable test to assess trauma radiograph interpretation performance

    International Nuclear Information System (INIS)

    Neep, M.J.; Steffens, T.; Riley, V.; Eastgate, P.; McPhail, S.M.

    2017-01-01

    Objectives: The purpose of this investigation was to develop and examine the preliminary validity and reliability among radiographers of a test to assess trauma radiograph interpretation performance suitable for use among health professionals. Methods: Stage 1 examined 14,159 consecutive appendicular and axial examinations from a hospital emergency department over a 12 month period to quantify a typical anatomical region case-mix of trauma radiographs. A sample of radiographic cases representative of affected anatomical regions was then developed into the Image Interpretation Test (IIT). Stage 2 involved prospective investigations of the IIT's reliability (inter-rater, intra-rater, internal consistency) and validity (concurrent) among 41 radiographers. Results: The IIT included 60 cases. The median (interquartile range) clinical experience of participants was 5 (2–10) years. Case scores were internally consistent (Cronbach's alpha = 0.90). Favourable inter-rater reliability (kappa > 0.70 for 58/60 cases, Intra-class correlation coefficient (ICC) > 0.99 for total score) and intra-rater reliability (kappa > 0.90 for 60/60 cases, ICC > 0.99 for total score) was observed. There was a positive association between radiographers' confidence in image interpretation and IIT score (coefficient = 1.52, r-squared = 0.60, p < 0.001). Conclusions: The IIT developed during this investigation included a selection of radiographic cases consistent with anatomical regions represented in an adult trauma case-mix. This study has also provided foundational preliminary evidence to support the reliability and validity of the IIT among radiographers. The findings suggest that it is possible to assess image interpretation performance of adult trauma radiographs with this test. - Highlights: • Development of an Image Interpretation Test (IIT). • Cases consistent with anatomical regions represented in a typical adult trauma case-mix. • Development of a

  14. Superconducting solenoid model magnet test results

    Energy Technology Data Exchange (ETDEWEB)

    Carcagno, R.; Dimarco, J.; Feher, S.; Ginsburg, C.M.; Hess, C.; Kashikhin, V.V.; Orris, D.F.; Pischalnikov, Y.; Sylvester, C.; Tartaglia, M.A.; Terechkine, I.; /Fermilab

    2006-08-01

    Superconducting solenoid magnets suitable for the room temperature front end of the Fermilab High Intensity Neutrino Source (formerly known as Proton Driver), an 8 GeV superconducting H- linac, have been designed and fabricated at Fermilab, and tested in the Fermilab Magnet Test Facility. We report here results of studies on the first model magnets in this program, including the mechanical properties during fabrication and testing in liquid helium at 4.2 K, quench performance, and magnetic field measurements. We also describe new test facility systems and instrumentation that have been developed to accomplish these tests.

  15. Superconducting solenoid model magnet test results

    International Nuclear Information System (INIS)

    Carcagno, R.; Dimarco, J.; Feher, S.; Ginsburg, C.M.; Hess, C.; Kashikhin, V.V.; Orris, D.F.; Pischalnikov, Y.; Sylvester, C.; Tartaglia, M.A.; Terechkine, I.; Tompkins, J.C.; Wokas, T.; Fermilab

    2006-01-01

    Superconducting solenoid magnets suitable for the room temperature front end of the Fermilab High Intensity Neutrino Source (formerly known as Proton Driver), an 8 GeV superconducting H- linac, have been designed and fabricated at Fermilab, and tested in the Fermilab Magnet Test Facility. We report here results of studies on the first model magnets in this program, including the mechanical properties during fabrication and testing in liquid helium at 4.2 K, quench performance, and magnetic field measurements. We also describe new test facility systems and instrumentation that have been developed to accomplish these tests

  16. Alternative filtration testing program: Pre-evaluation of test results

    International Nuclear Information System (INIS)

    Georgeton, G.K.; Poirier, M.R.

    1990-01-01

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing

  17. Alternative filtration testing program: Pre-evaluation of test results

    Energy Technology Data Exchange (ETDEWEB)

    Georgeton, G.K.; Poirier, M.R.

    1990-09-28

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing.

  18. Test results of HTTR control system

    International Nuclear Information System (INIS)

    Motegi, Toshihiro; Iigaki, Kazuhiko; Saito, Kenji; Sawahata, Hiroaki; Hirato, Yoji; Kondo, Makoto; Shibutani, Hideki; Ogawa, Satoru; Shinozaki, Masayuki; Mizushima, Toshihiko; Kawasaki, Kozo

    2006-06-01

    The plant control performance of the IHX helium flow rate control system, the PPWC helium flow rate control system, the secondary helium flow rate control system, the inlet temperature control system, the reactor power control system and the outlet temperature control system of the HTTR are obtained through function tests and power-up tests. As the test results, the control systems show stable control response under transient condition. Both of inlet temperature control system and reactor power control system shows stable operation from 30% to 100%, respectively. This report describes the outline of control systems and test results. (author)

  19. Test-retest reliability and cross validation of the functioning everyday with a wheelchair instrument.

    Science.gov (United States)

    Mills, Tamara L; Holm, Margo B; Schmeler, Mark

    2007-01-01

    The purpose of this study was to establish the test-retest reliability and content validity of an outcomes tool designed to measure the effectiveness of seating-mobility interventions on the functional performance of individuals who use wheelchairs or scooters as their primary seating-mobility device. The instrument, Functioning Everyday With a Wheelchair (FEW), is a questionnaire designed to measure perceived user function related to wheelchair/scooter use. Using consumer-generated items, FEW Beta Version 1.0 was developed and test-retest reliability was established. Cross-validation of FEW Beta Version 1.0 was then carried out with five samples of seating-mobility users to establish content validity. Based on the content validity study, FEW Version 2.0 was developed and administered to seating-mobility consumers to examine its test-retest reliability. FEW Beta Version 1.0 yielded an intraclass correlation coefficient (ICC) Model (3,k) of .92, p content validity results revealed that FEW Beta Version 1.0 captured 55% of seating-mobility goals reported by consumers across five samples. FEW Version 2.0 yielded ICC(3,k) = .86, p content validity of FEW Version 2.0 was confirmed. FEW Beta Version 1.0 and FEW Version 2.0 were highly stable in their measurement of participants' seating-mobility goals over a 1-week interval.

  20. The Comprehensive Snack Parenting Questionnaire (CSPQ: Development and Test-Retest Reliability

    Directory of Open Access Journals (Sweden)

    Dorus W. M. Gevers

    2018-04-01

    Full Text Available The narrow focus of existing food parenting instruments led us to develop a food parenting practices instrument measuring the full range of food practices constructs with a focus on snacking behavior. We present the development of the questionnaire and our research on the test-retest reliability. The developed Comprehensive Snack Parenting Questionnaire (CSPQ covers 21 constructs. Test-retest reliability was assessed by calculating intra class correlation coefficients and percentage agreement after two administrations of the CSPQ among a sample of 66 Dutch parents. Test-retest reliability analysis revealed acceptable intra class correlation coefficients (≥0.41 or agreement scores (≥0.60 for all items. These results, together with earlier work, suggest sufficient psychometric characteristics. The comprehensive, but brief CSPQ opens up chances for highly essential but unstudied research questions to understand and predict children’s snack intake. Example applications include studying the interactional nature of food parenting practices or interactions of food parenting with general parenting or child characteristics.

  1. Development of a Saudi Food Frequency Questionnaire and testing its reliability and validity.

    Science.gov (United States)

    Gosadi, Ibrahim M; Alatar, Abdullah A; Otayf, Mojahed M; AlJahani, Dhaherah M; Ghabbani, Hisham M; AlRajban, Waleed A; Alrsheed, Abdullah M; Al-Nasser, Khalid A

    2017-06-01

    To create a food frequency questionnaire specifically designed to capture the dietary habits of Saudis and test its validity and reliability. Methods: This investigation is a longitudinal, test-retest study conducted in King Saud University, Riyadh, Kingdom of Saudi Arabia between December 2015 and March 2016. A list of 140 food items was included in the questionnaire where a closed-ended and open-ended approach was used. Regarding past   year food frequency consumption and 24 hours dietary recall, body weight and height were collected. Internal consistency, test-retest reliability, completeness of the food list, and criterion validity were assessed. Results: One-hundred and thirty eight participants were interviewed to complete the 24 hours dietary recall and the constructed questionnaire. Approximately 85% of the food items reported in the dietary recall were covered in the food frequency questionnaire. The association of body mass index with meats (regression coefficients: 2.28) and dairy products consumption frequency was statistically significant (regression coefficients: 2.31). A high overall reproducibility rate of the questionnaire was detected (Pearsons' correlation coefficient: 0.78 p less than 0.001).  Conclusion: The developed questionnaire has a high reliability and reasonable validity, and suitable for use in nutritional epidemiological investigations in Saudi Arabia.

  2. Test-retest reliability of a questionnaire to assess physical environmental factors pertaining to physical activity

    Directory of Open Access Journals (Sweden)

    McGinn Aileen P

    2005-06-01

    Full Text Available Abstract Background Despite the documented benefits of physical activity, many adults do not obtain the recommended amounts. Barriers to physical activity occur at multiple levels, including at the individual, interpersonal, and environmental levels. Only until more recently has there been a concerted focus on how the physical environment might affect physical activity behavior. With this new area of study, self-report measures should be psychometrically tested before use in research studies. Therefore the objective of this study was to document the test-retest reliability of a questionnaire designed to assess physical environmental factors that might be associated with physical activity in a diverse adult population. Methods Test and retest surveys were conducted over the telephone with 106 African American and White women and men living in either Forsyth County, North Carolina or Jackson, Mississippi. Reliability of self-reported environmental factors across four domains (e.g., access to facilities and destinations, functionality and safety, aesthetics, natural environment was determined using intraclass correlation coefficients (ICC overall and separately by gender and race. Results Generally items displayed moderate and sometimes substantial reliability (ICC between 0.4 to 0.8, with a few differences by gender or race, across each of the domains. Conclusion This study provides some psychometric evidence for the use of many of these questions in studies examining the effect of self-reported physical environmental measures on physical activity behaviors, among African American and White women and men.

  3. Feasibility and reliability of physical fitness tests in older adults with intellectual disability : A pilot study

    NARCIS (Netherlands)

    Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    Background Physical fitness is relevant for wellbeing and health, but knowledge on the feasibility and reliability of instruments to measure physical fitness for older adults with intellectual disability is lacking. Methods Feasibility and test-retest reliability of a physical fitness test battery

  4. Statistical Considerations in Choosing a Test Reliability Coefficient. ACT Research Report Series, 2012 (10)

    Science.gov (United States)

    Woodruff, David; Wu, Yi-Fang

    2012-01-01

    The purpose of this paper is to illustrate alpha's robustness and usefulness, using actual and simulated educational test data. The sampling properties of alpha are compared with the sampling properties of several other reliability coefficients: Guttman's lambda[subscript 2], lambda[subscript 4], and lambda[subscript 6]; test-retest reliability;…

  5. Reliability and validity of the rey visual design learning test in primary school children

    NARCIS (Netherlands)

    Wilhelm, P.

    2004-01-01

    The Rey Visual Design Learning Test (Rey, 1964, in Spreen & Strauss, 1991) assesses immediate memory span, new learning and recognition for non-verbal material. Three studies are presented that focused on the reliability and validity of the RVDLT in primary school children. Test-retest reliability

  6. Stand development and reliability tests of the thermal monitoring means for NPP

    International Nuclear Information System (INIS)

    Nalivaev, V.I.; Nikul'shin, V.S.; Kichigin, A.B.; Dirin, V.F.

    2003-01-01

    The paper is devoted to the reliability tests of thermoelectric thermometers and resistance thermometers during their operation in the nominal mode. Five stands Reliability are developed and operate for realization of tests of all manufactured thermal converters. delivered at NPP. Description of all stands are presented [ru

  7. Research Note The reliability of a field test kit for the detection and ...

    African Journals Online (AJOL)

    Research Note The reliability of a field test kit for the detection and the persistence of ... Open Access DOWNLOAD FULL TEXT ... The objectives were to test a field kit for practicality and reliability, to assess the spread of the bacteria among ...

  8. Comparison of reading performance tests concerning difficulty of sentences and paragraphs and their reliability

    NARCIS (Netherlands)

    Brussee, T.; van Nispen, R.M.A.; Klerkx, E.M.F.J.; Knol, D.L.; van Rens, G.H.M.B.

    2015-01-01

    In research and practice, sentences or paragraphs of reading tests may be randomly chosen to assess reading performance. This means that in addition to test reliability, all sentences or paragraphs should be reliable and equally difficult to read. The sentences and paragraphs of five (un-)

  9. Test-Retest Reliability of a Survey to Measure Transport-Related Physical Activity in Adults

    Science.gov (United States)

    Badland, Hannah; Schofield, Grant

    2006-01-01

    The present research details test-retest reliability of a newly developed, telephone-administered TPA survey for adults. This instrument examines barriers, perceptions, and current travel behaviors to place of work/study and local convenience shops. Demonstrated test-retest reliability of the Active Friendly Environments-Transport-Related Physical…

  10. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Science.gov (United States)

    Tidstrand, Johan; Horneij, Eva

    2009-01-01

    Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar

  11. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Directory of Open Access Journals (Sweden)

    Tidstrand Johan

    2009-06-01

    Full Text Available Abstract Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs. Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0, for sitting on a Bobath ball good (κ: 0.79 and very good (κ: 0.88 and for the unilateral pelvic lift: good (κ: 0.61 and moderate (κ: 0.47. Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their

  12. Validity and reliability testing of the Prenatal Psychosocial Profile.

    Science.gov (United States)

    Curry, M A; Campbell, R A; Christian, M

    1994-04-01

    Two studies of low-income pregnant women (N = 179) were done to examine the validity and reliability of the Prenatal Psychosocial Profile (PPP). The PPP, a composite of the Rosenberg Self-Esteem Scale, the Support Behaviors Inventory, and a newly developed measure of stress, is a brief, comprehensive clinical assessment of psychosocial risk during pregnancy. Construct validity of the stress scale was supported by theoretically predicted negative correlations with self-esteem, partner support, and support from others (N = 91). Convergent validity of the stress scale was demonstrated by a correlation of .71 with the Difficult Life Circumstances Scale. Adequate levels of internal consistency were found. Interrelationships between the four subscales were consistent with the underlying conceptualization, and there was beginning evidence of the factorial independence of the subscales.

  13. NASA preferred reliability-practices for design and test

    Science.gov (United States)

    Lisk, Ronald C.

    1992-01-01

    NASA HQ established the NASA R&M Steering Committee (R&MSC) comprised of membership from each NASA field center. The primary charter of the R&MSC is to obtain, record, and share the best design practices that NASA has applied to successful space flight programs and current design considerations (guidelines) that should enhance flight reliability on emerging programs. The practices and guidelines are being assembled in a living document for distribution to NASA centers and the aerospace community. The document will be updated annually with additional practices and guidelines as contributions from the centers are reviewed and approved by the R&MSC. Practices and guidelines are not requirements, but rather a means of sharing procedures and techniques that a given center and the R&MSC together feel have strong technical merit and application to the design of space-related equipment.

  14. TEST-RETEST RELIABILITY OF THE CLOSED KINETIC CHAIN UPPER EXTREMITY STABILITY TEST (CKCUEST) IN ADOLESCENTS: RELIABILITY OF CKCUEST IN ADOLESCENTS.

    Science.gov (United States)

    de Oliveira, Valéria M A; Pitangui, Ana C R; Nascimento, Vinícius Y S; da Silva, Hítalo A; Dos Passos, Muana H P; de Araújo, Rodrigo C

    2017-02-01

    The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) has been proposed as an option to assess upper limb function and stability; however, there are few studies that support the use of this test in adolescents. The purpose of the present study was to investigate the intersession reliability and agreement of three CKCUEST scores in adolescents and establish clinimetric values for this test. Test-retest reliability. Twenty-five healthy adolescents of both sexes were evaluated. The subjects performed two CKCUEST with an interval of one week between the tests. An intraclass correlation coefficient (ICC 3,3 ) two-way mixed model with a 95% interval of confidence was utilized to determine intersession reliability. A Bland-Altman graph was plotted to analyze the agreement between assessments. The presence of systematic error was evaluated by a one-sample t test. The difference between the evaluation and reevaluation was observed using a paired-sample t test. The level of significance was set at 0.05. Standard error of measurements and minimum detectable changes were calculated. The intersession reliability of the average touches score, normalized score, and power score were 0.68, 0.68 and 0.87, the standard error of measurement were 2.17, 1.35 and 6.49, and the minimal detectable change was 6.01, 3.74 and 17.98, respectively. The presence of systematic error (p test with moderate to excellent reliability when used with adolescents. The CKCUEST is a measurement with moderate to excellent reliability for adolescents. 2b.

  15. BWR Full Integral Simulation Test (FIST). Phase I test results

    International Nuclear Information System (INIS)

    Hwang, W.S.; Alamgir, M.; Sutherland, W.A.

    1984-09-01

    A new full height BWR system simulator has been built under the Full-Integral-Simulation-Test (FIST) program to investigate the system responses to various transients. The test program consists of two test phases. This report provides a summary, discussions, highlights and conclusions of the FIST Phase I tests. Eight matrix tests were conducted in the FIST Phase I. These tests have investigated the large break, small break and steamline break LOCA's, as well as natural circulation and power transients. Results and governing phenomena of each test have been evaluated and discussed in detail in this report. One of the FIST program objectives is to assess the TRAC code by comparisons with test data. Two pretest predictions made with TRACB02 are presented and compared with test data in this report

  16. Intra and Inter-Rater Reliability of Screening for Movement Impairments: Movement Control Tests from The Foundation Matrix

    Science.gov (United States)

    Mischiati, Carolina R.; Comerford, Mark; Gosford, Emma; Swart, Jacqueline; Ewings, Sean; Botha, Nadine; Stokes, Maria; Mottram, Sarah L.

    2015-01-01

    Pre-season screening is well established within the sporting arena, and aims to enhance performance and reduce injury risk. With the increasing need to identify potential injury with greater accuracy, a new risk assessment process has been produced; The Performance Matrix (battery of movement control tests). As with any new method of objective testing, it is fundamental to establish whether the same results can be reproduced between examiners and by the same examiner on consecutive occasions. This study aimed to determine the intra-rater test re-test and inter-rater reliability of tests from a component of The Performance Matrix, The Foundation Matrix. Twenty participants were screened by two experienced musculoskeletal therapists using nine tests to assess the ability to control movement during specific tasks. Movement evaluation criteria for each test were rated as pass or fail. The therapists observed participants real-time and tests were recorded on video to enable repeated ratings four months later to examine intra-rater reliability (videos rated two weeks apart). Overall test percentage agreement was 87% for inter-rater reliability; 98% Rater 1, 94% Rater 2 for test re-test reliability; and 75% for real-time versus video. Intraclass-correlation coefficients (ICCs) were excellent between raters (0.81) and within raters (Rater 1, 0.96; Rater 2, 0.88) but poor for real-time versus video (0.23). Reliability for individual components of each test was more variable: inter-rater, 68-100%; intra-rater, 88-100% Rater 1, 75-100% Rater 2; and real-time versus video 31-100%. Cohen’s Kappa values for inter-rater reliability were 0.0-1.0; intra-rater 0.6-1.0 for Rater 1; -0.1-1.0 for Rater 2; and -0.1-1 for real-time versus video. It is concluded that both inter and intra-rater reliability of tests in The Foundation Matrix are acceptable when rated by experienced therapists. Recommendations are made for modifying some of the criteria to improve reliability where

  17. Reliability of the Timed Up and Go test and Ten-Metre Timed Walk Test in Pregnant Women with Pelvic Girdle Pain.

    Science.gov (United States)

    Evensen, Natalie M; Kvåle, Alice; Braekken, Ingeborg H

    2015-09-01

    There is a lack of functional objective tests available to measure functional status in women with pelvic girdle pain (PGP). The purpose of this study was to establish test-retest and intertester reliability of the Timed Up and Go (TUG) test and Ten-metre Timed Walk Test (10mTWT) in pregnant women with PGP. A convenience sample of women was recruited over a 4-month period and tested on two occasions, 1 week apart to determine test-retest reliability. Intertester reliability was established between two assessors at the first testing session. Subjects were instructed to undertake the TUG and 10mTWT at maximum speed. One practise trial and two timed trials for each walking test was undertaken on Day 1 and one practise trial and one timed trial on Day 2. Seventeen women with PGP aged 31.1 years (SD [standard deviation] = 2.3) and 28.7 weeks pregnant (SD = 7.4) completed gait testing. Test-retest reliability using the intraclass correlation coefficient (ICC) was excellent for the TUG (0.88) and good for the 10mTWT (0.74). Intertester reliability was determined in the first 13 participants with excellent ICC values being found for both walking tests (TUG: 0.95; 10mTWT: 0.94). This study demonstrated that the TUG and 10mTWT undertaken at fast pace are reliable, objective functional tests in pregnant women with PGP. While both tests are suitable for use in the clinical and research settings, we would recommend the TUG given the findings of higher test-retest reliability and as this test requires less space and time to set up and score. Future studies in a larger sample size are warranted to confirm the results of this study. Copyright © 2015 John Wiley & Sons, Ltd.

  18. The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain

    Science.gov (United States)

    2013-01-01

    Background This study investigates the reliability of muscle performance tests using cost- and time-effective methods similar to those used in clinical practice. When conducting reliability studies, great effort goes into standardising test procedures to facilitate a stable outcome. Therefore, several test trials are often performed. However, when muscle performance tests are applied in the clinical setting, clinicians often only conduct a muscle performance test once as repeated testing may produce fatigue and pain, thus variation in test results. We aimed to investigate whether cervical muscle performance tests, which have shown promising psychometric properties, would remain reliable when examined under conditions similar to those of daily clinical practice. Methods The intra-rater (between-day) and inter-rater (within-day) reliability was assessed for five cervical muscle performance tests in patients with (n = 33) and without neck pain (n = 30). The five tests were joint position error, the cranio-cervical flexion test, the neck flexor muscle endurance test performed in supine and in a 45°-upright position and a new neck extensor test. Results Intra-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.48-0.82), the cranio-cervical flexion test (ICC ≥ 0.69), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.68) and in a 45°-upright position (ICC ≥ 0.41) with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement (ICC = 0.14-0.41). Likewise, inter-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.51-0.75), the cranio-cervical flexion test (ICC ≥ 0.85), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.70) and in a 45°-upright position (ICC ≥ 0.56). However, only slight to fair agreement was found for the neck extensor test (ICC

  19. Test-Retest Reliability of Isokinetic Knee Strength Measurements in Children Aged 8 to 10 Years.

    Science.gov (United States)

    Fagher, Kristina; Fritzson, Annelie; Drake, Anna Maria

    Isokinetic dynamometry is a useful tool to objectively assess muscle strength of children and adults in athletic and rehabilitative settings. This study examined test-retest reliability of isokinetic knee strength measurements in children aged 8 to 10 years and defined limits for the minimum difference (MD) in strength that indicates a clinically important change. Isokinetic knee strength measurements (using the Biodex System 4) in children will provide reliable results. Descriptive laboratory study. In 22 healthy children, 5 maximal concentric (CON) knee extensor (KE) and knee flexor (KF) contractions at 2 angular velocities (60 deg/s and 180 deg/s) and 5 maximal eccentric (ECC) KE/KF contractions at 60 deg/s were assessed 7 days apart. The intraclass correlation coefficient (ICC 2.1 ) was used to examine relative reliability, and the MD was calculated on the basis of standard error of measurement. ICCs for CON KE/KF peak torque measurements were fair to excellent (range, 0.49-0.81). The MD% values for CON KE and KF ranged from 31% to 37% at 60 deg/s and from 34% to 39% at 180 deg/s. ICCs in the ECC mode were good (range, 0.60-0.70), but associated MD% values were high (>50%). There was no systematic error for CON KE/KF and ECC KE strength measurements at 60 deg/s, but systematic error was found for all other measurements. The dynamometer provides a reliable analysis of isokinetic CON knee strength measurements at 60 deg/s in children aged 8 to 10 years. Measurements at 180 deg/s and in the ECC mode were not reliable, indicating a need for more familiarization prior to testing. The MD values may help clinicians to determine whether a change in knee strength is due to error or intervention.

  20. Are chiropractic tests for the lumbo-pelvic spine reliable and valid? A systematic critical literature review

    DEFF Research Database (Denmark)

    Hestbaek, L; Leboeuf-Yde, C

    2000-01-01

    OBJECTIVE: To systematically review the peer-reviewed literature about the reliability and validity of chiropractic tests used to determine the need for spinal manipulative therapy of the lumbo-pelvic spine, taking into account the quality of the studies. DATA SOURCES: The CHIROLARS database......-pelvic spine were included. DATA EXTRACTION: Data quality were assessed independently by the two reviewers, with a quality score based on predefined methodologic criteria. Results of the studies were then evaluated in relation to quality. DATA SYNTHESIS: None of the tests studied had been sufficiently...... evaluated in relation to reliability and validity. Only tests for palpation for pain had consistently acceptable results. Motion palpation of the lumbar spine might be valid but showed poor reliability, whereas motion palpation of the sacroiliac joints seemed to be slightly reliable but was not shown...

  1. Increasing the reliability of the fluid/crystallized difference score from the Kaufman Adolescent and Adult Intelligence Test with reliable component analysis.

    Science.gov (United States)

    Caruso, J C

    2001-06-01

    The unreliability of difference scores is a well documented phenomenon in the social sciences and has led researchers and practitioners to interpret differences cautiously, if at all. In the case of the Kaufman Adult and Adolescent Intelligence Test (KAIT), the unreliability of the difference between the Fluid IQ and the Crystallized IQ is due to the high correlation between the two scales. The consequences of the lack of precision with which differences are identified are wide confidence intervals and unpowerful significance tests (i.e., large differences are required to be declared statistically significant). Reliable component analysis (RCA) was performed on the subtests of the KAIT in order to address these problems. RCA is a new data reduction technique that results in uncorrelated component scores with maximum proportions of reliable variance. Results indicate that the scores defined by RCA have discriminant and convergent validity (with respect to the equally weighted scores) and that differences between the scores, derived from a single testing session, were more reliable than differences derived from equal weighting for each age group (11-14 years, 15-34 years, 35-85+ years). This reliability advantage results in narrower confidence intervals around difference scores and smaller differences required for statistical significance.

  2. Reliability Of Kraus-Weber Exercise Test As An Evaluation Tool In ...

    African Journals Online (AJOL)

    Reliability Of Kraus-Weber Exercise Test As An Evaluation Tool In Low Back ... strength and flexibility of the back, abdominal, psoas and hamstring muscles. ... Keywords: Kraus-Weber test, low back pain, muscle flexibility, muscle strength.

  3. SULTAN test facility: Summary of recent results

    International Nuclear Information System (INIS)

    Stepanov, Boris; Bruzzone, Pierluigi; Sedlak, Kamil; Croari, Giancarlo

    2013-01-01

    The test campaigns of the ITER conductors in the SULTAN test facility re-started in December 2011 after three months break. The main focus of the activities is about the qualification tests of the Central Solenoid (CS) conductors, with three different samples for a total six variations of strand suppliers and cable layouts. In 2012, five Toroidal Field (TF) conductor samples have also been tested as part of the supplier and process qualification phase of the European, Korean, Chinese and Russian Federation Agencies. A summary of the test results for all the ITER samples tested in the last period is presented, including an updated statistics of the broad transition, the performance degradation and the impact of layout variations. The role of SULTAN test facility during the ITER construction is reviewed, and the load of work for the next three years is anticipated

  4. Production LHC HTS power lead test results

    CERN Document Server

    Tartaglia, M; Fehér, S; Huang, Y; Orris, D F; Pischalnikov, Y; Rabehl, Roger Jon; Sylvester, C D; Zbasnik, J

    2005-01-01

    The Fermilab Magnet test facility has built and operated a test stand to characterize the performance of HTS power leads. We report here the results of production tests of 20 pairs of 7.5 kA HTS power leads manufactured by industry for installation in feed boxes for the LHC Interaction Region quadrupole strings. Included are discussions of the thermal, electrical, and quench characteristics under "standard" and "extreme" operating conditions, and the stability of performance across thermal cycles.

  5. Production LHC HTS power lead test results

    International Nuclear Information System (INIS)

    Tartaglia, M.A.; Carcagno, R.H.; Feher, S.; Huang, Y.; Orris, D.F.; Pischalnikov, Y.; Rabehl, R.J.; Sylvester, C.; Zbasnik, J.

    2004-01-01

    The Fermilab Magnet test facility has built and operated a test stand to characterize the performance of HTS power leads. We report here the results of production tests of 20 pairs of 7.5 kA HTS power leads manufactured by industry for installation in feed boxes for the LHC Interaction Region quadrupole strings. Included are discussions of the thermal, electrical, and quench characteristics under ''standard'' and ''extreme'' operating conditions, and the stability of performance across thermal cycles

  6. Resting-state test-retest reliability of a priori defined canonical networks over different preprocessing steps.

    Science.gov (United States)

    Varikuti, Deepthi P; Hoffstaedter, Felix; Genon, Sarah; Schwender, Holger; Reid, Andrew T; Eickhoff, Simon B

    2017-04-01

    Resting-state functional connectivity analysis has become a widely used method for the investigation of human brain connectivity and pathology. The measurement of neuronal activity by functional MRI, however, is impeded by various nuisance signals that reduce the stability of functional connectivity. Several methods exist to address this predicament, but little consensus has yet been reached on the most appropriate approach. Given the crucial importance of reliability for the development of clinical applications, we here investigated the effect of various confound removal approaches on the test-retest reliability of functional-connectivity estimates in two previously defined functional brain networks. Our results showed that gray matter masking improved the reliability of connectivity estimates, whereas denoising based on principal components analysis reduced it. We additionally observed that refraining from using any correction for global signals provided the best test-retest reliability, but failed to reproduce anti-correlations between what have been previously described as antagonistic networks. This suggests that improved reliability can come at the expense of potentially poorer biological validity. Consistent with this, we observed that reliability was proportional to the retained variance, which presumably included structured noise, such as reliable nuisance signals (for instance, noise induced by cardiac processes). We conclude that compromises are necessary between maximizing test-retest reliability and removing variance that may be attributable to non-neuronal sources.

  7. Resting-state test-retest reliability of a priori defined canonical networks over different preprocessing steps

    Science.gov (United States)

    Varikuti, Deepthi P.; Hoffstaedter, Felix; Genon, Sarah; Schwender, Holger; Reid, Andrew T.; Eickhoff, Simon B.

    2016-01-01

    Resting-state functional connectivity analysis has become a widely used method for the investigation of human brain connectivity and pathology. The measurement of neuronal activity by functional MRI, however, is impeded by various nuisance signals that reduce the stability of functional connectivity. Several methods exist to address this predicament, but little consensus has yet been reached on the most appropriate approach. Given the crucial importance of reliability for the development of clinical applications, we here investigated the effect of various confound removal approaches on the test-retest reliability of functional-connectivity estimates in two previously defined functional brain networks. Our results showed that grey matter masking improved the reliability of connectivity estimates, whereas de-noising based on principal components analysis reduced it. We additionally observed that refraining from using any correction for global signals provided the best test-retest reliability, but failed to reproduce anti-correlations between what have been previously described as antagonistic networks. This suggests that improved reliability can come at the expense of potentially poorer biological validity. Consistent with this, we observed that reliability was proportional to the retained variance, which presumably included structured noise, such as reliable nuisance signals (for instance, noise induced by cardiac processes). We conclude that compromises are necessary between maximizing test-retest reliability and removing variance that may be attributable to non-neuronal sources. PMID:27550015

  8. [Testing reliability and validity of reduced substitutes for leadership scales(rd-SLS)].

    Science.gov (United States)

    Kim, Jeong-Hee

    2005-10-01

    This paper was conducted to test the reliability and validity of rd-SLS, developed by Podsakoff, et al. (1993) which measured 'substitutes for leadership'. The subjects were 345 nurses in 5 general hospitals. Cronbach's and the Guttman split-half coefficient were used to test the reliability of rd-SLS. Factor analysis, and the correlations of the rv-SLS and SLS with rd-SLS were used for convergent and discriminant validity. Cronbach's data was 0.76 and the Guttman split-half coefficient was 0.52. Twelve factors evolved by factor analysis, which explained 70.4% of the total variance. This result was similar to previous study results. However, 'Indifference toward organizational rewards'-related items were classified two factors. It was not clear t hat the rd-SLS consisted of 13 concepts(factors). The correlations of the rv-SLS and SLS with the rd-SLS were 0.93 and 0.87 respectively. The rd-SLS showed a moderate degree of validity and reliability. Thus, it is recommended to use the rd-SLS in general nursing organizations for screening for leadership substitutes. In addition, it is necessary to clarify the concept of organizational rewards. In a further study, the factor structure of the rd-SLS may be considered.

  9. Reliability and accuracy of Cooper's test in male long distance runners

    OpenAIRE

    J.R. Alvero-Cruz; M.A. Giráldez García; E.A. Carnero

    2017-01-01

    Objective: Endurance capacity can be assessed by field test such as Cooper's test; however, reliability and accuracy are rarely reported in the literature. It was our aims to describe reliability and accuracy of Cooper's test in long distance runners. Method: Fifteen male long distance runners performed twice all-out Cooper's test in a 400 m track. Total distance covered, maximum heart rate (HR) and rate of perceived exertion were recorded. Bias correction factor (Bc) was used to describe ...

  10. Prototype bellows sealed nuclear valve development -reliability through testing

    International Nuclear Information System (INIS)

    Dixon, D.F.; Abbas, M.

    1978-01-01

    To assist in appraising bellows sealed valve performance, 10 tests were done on a ''1 in.'' prototype bellows sealed valve design. The tests simulated primary heat transport (PHT) system conditions for a 600 MWe CANDU-PHW. The design approach was to have all valve components outlast the bellows in endurance tests; this was achieved. The valve design meets the Atomic Energy of Canada Limited specification. For comparison, bellows fatigue failure data were fitted to both log-normal and Weibull distributions. A numerical example shows how to select valve stroke amplitude on the basis of valve flow requirement and the minimum acceptable fatigue life. (author)

  11. Reliability of genetic bottleneck tests for detecting recent population declines

    NARCIS (Netherlands)

    Peery, M. Zachariah; Kirby, Rebecca; Reid, Brendan N.; Stoelting, Ricka; Doucet-Beer, Elena; Robinson, Stacie; Vasquez-Carrillo, Catalina; Pauli, Jonathan N.; Palsboll, Per J.

    The identification of population bottlenecks is critical in conservation because populations that have experienced significant reductions in abundance are subject to a variety of genetic and demographic processes that can hasten extinction. Genetic bottleneck tests constitute an appealing and

  12. Reliability and convergent validity of the five-step test in people with chronic stroke.

    Science.gov (United States)

    Ng, Shamay S M; Tse, Mimi M Y; Tam, Eric W C; Lai, Cynthia Y Y

    2018-01-10

    (i) To estimate the intra-rater, inter-rater and test-retest reliabilities of the Five-Step Test (FST), as well as the minimum detectable change in FST completion times in people with stroke. (ii) To estimate the convergent validity of the FST with other measures of stroke-specific impairments. (iii) To identify the best cut-off times for distinguishing FST performance in people with stroke from that of healthy older adults. A cross-sectional study. University-based rehabilitation centre. Forty-eight people with stroke and 39 healthy controls. None. The FST, along with (for the stroke survivors only) scores on the Fugl-Meyer Lower Extremity Assessment (FMA-LE), the Berg Balance Scale (BBS), Limits of Stability (LOS) tests, and Activities-specific Balance Confidence (ABC) scale were tested. The FST showed excellent intra-rater (intra-class correlation coefficient; ICC = 0.866-0.905), inter-rater (ICC = 0.998), and test-retest (ICC = 0.838-0.842) reliabilities. A minimum detectable change of 9.16 s was found for the FST in people with stroke. The FST correlated significantly with the FMA-LE, BBS, and LOS results in the forward and sideways directions (r = -0.411 to -0.716, p people with stroke and healthy older adults. The FST is a reliable, easy-to-administer clinical test for assessing stroke survivors' ability to negotiate steps and stairs.

  13. Relative and Absolute Reliability of Timed Up and Go Test in Community Dwelling Older Adult and Healthy Young People

    Directory of Open Access Journals (Sweden)

    Farhad Azadi

    2014-01-01

    Full Text Available Objectives: Relative and absolute reliability are psychometric properties of the test that many clinical decisions are based on them. In many cases, only relative reliability takes into consideration while the absolute reliability is also very important. Methods & Materials: Eleven community-dwelling older adults aged 65 years and older (69.64±3.58 and 20 healthy young in the age range 20 to 35 years (28.80±4.15 using three versions of Timed Up and Go test were evaluated twice with an interval of 2 to 5 days. Results: Generally, the non-homogeneity of the study population was stratified to increase the Intra-class Correlation Coefficient (ICC this coefficient in elderly people is greater than young people and with a secondary task is reduced. In This study, absolute reliability indices using different data sources and equations lead to in more or less similar results. At general, in test–retest situations, the elderly more than the young people must be changed to be interpreted as a real change, not random. The random error contribution is slightly greater in elderly than young and with a secondary task is increased.It seems, heterogeneity leads to moderation in absolute reliability indices. Conclusion: In relative reliability studies, researchers and clinicians should pay attention to factors such as homogeneity of population and etc. As well as, absolute reliability beside relative reliability is needed and necessary in clinical decision making.

  14. Validity and Reliability of Published Comprehensive Theory of Mind Tests for Normal Preschool Children: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Seyyede Zohreh Ziatabar Ahmadi

    2015-12-01

    Full Text Available Objective: Theory of mind (ToM or mindreading is an aspect of social cognition that evaluates mental states and beliefs of oneself and others. Validity and reliability are very important criteria when evaluating standard tests; and without them, these tests are not usable. The aim of this study was to systematically review the validity and reliability of published English comprehensive ToM tests developed for normal preschool children.Method: We searched MEDLINE (PubMed interface, Web of Science, Science direct, PsycINFO, and also evidence base Medicine (The Cochrane Library databases from 1990 to June 2015. Search strategy was Latin transcription of ‘Theory of Mind’ AND test AND children. Also, we manually studied the reference lists of all final searched articles and carried out a search of their references. Inclusion criteria were as follows: Valid and reliable diagnostic ToM tests published from 1990 to June 2015 for normal preschool children; and exclusion criteria were as follows: the studies that only used ToM tests and single tasks (false belief tasks for ToM assessment and/or had no description about structure, validity or reliability of their tests. Methodological quality of the selected articles was assessed using the Critical Appraisal Skills Programme (CASP.Result: In primary searching, we found 1237 articles in total databases. After removing duplicates and applying all inclusion and exclusion criteria, we selected 11 tests for this systematic review. Conclusion: There were a few valid, reliable and comprehensive ToM tests for normal preschool children. However, we had limitations concerning the included articles. The defined ToM tests were different in populations, tasks, mode of presentations, scoring, mode of responses, times and other variables. Also, they had various validities and reliabilities. Therefore, it is recommended that the researchers and clinicians select the ToM tests according to their psychometric

  15. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease.

    Science.gov (United States)

    Strouwen, Carolien; Molenaar, Esther A L M; Keus, Samyra H J; Münks, Liesbeth; Bloem, Bastiaan R; Nieuwboer, Alice

    2016-08-01

    Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains largely unknown. The purpose of this study was to assess the reliability of DT outcome measures in patients with PD. A repeated-measures design was used. Patients with PD ("on" medication, Mini-Mental State Examination score ≥24) performed 2 cognitive tasks (ie, backward digit span task and auditory Stroop task) and 1 functional task (ie, mobile phone task) in combination with walking. Tasks were assessed at 2 time points (same hour) with an interval of 6 weeks. Test-retest reliability was assessed for gait while performing each secondary task (DT gait) for both cognitive tasks while walking (DT cognitive) and for the functional task while walking (DT functional). Sixty-two patients with PD (age=39-89 years, Hoehn and Yahr stages II-III) were included in the study. Intraclass correlation coefficients (ICCs) showed excellent reliability for DT gait measures, ranging between .86 and .95 when combined with the digit span task, between .86 and .95 when combined with the auditory Stroop task, and between .72 and .90 when combined with the mobile phone task. The standard error of measurements for DT gait speed varied between 0.06 and 0.08 m/s, leading to minimal detectable changes between 0.16 and 0.22 m/s. With regard to DT cognitive measures, reaction times showed good-to-excellent reliability (digit span task: ICC=.75; auditory Stroop task: ICC=.82). The results cannot be generalized to patients with advanced disease or to other DT measures. In people with PD, DT measures proved to be reliable for use in clinical studies and look promising for use in clinical practice to assess improvements after DT training. Large effects, however, are needed to obtain meaningful effect sizes.

  16. Is gait variability reliable in older adults and Parkinson's disease? Towards an optimal testing protocol.

    Science.gov (United States)

    Galna, Brook; Lord, Sue; Rochester, Lynn

    2013-04-01

    Despite the widespread use of gait variability in research and clinical studies, testing protocols designed to optimise its reliability have not been established. This study evaluates the impact of testing protocol and pathology on the reliability of gait variability. To (i) estimate the reliability of gait variability during continuous and intermittent walking protocols in older adults and people with Parkinson's disease (PD), (ii) determine optimal number of steps for acceptable levels of reliability of gait variability and (iii) provide sample size estimates for use in clinical trials. Gait variability was measured twice, one week apart, in 27 older adults and 25 PD participants. Participants walked at their preferred pace during: (i) a continuous 2 min walk and (ii) 3 intermittent walks over a 12 m walkway. Gait variability was calculated as the within-person standard deviation for step velocity, length and width, and step, stance and swing duration. Reliability of gait variability ranged from poor to excellent (intra class correlations .041-.860; relative limits of agreement 34-89%). Gait variability was more reliable during continuous walks. Control and PD participants demonstrated similar reliability. Increasing the number of steps improved reliability, with most improvement seen across the first 30 steps. In this study, we identified testing protocols that improve the reliability of measuring gait variability. We recommend using a continuous walking protocol and to collect no fewer than 30 steps. Early PD does not appear to impact negatively on the reliability of gait variability. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Reliability and number of trials of Y Balance Test in adolescent athletes.

    Science.gov (United States)

    Linek, Pawel; Sikora, Damian; Wolny, Tomasz; Saulicz, Edward

    2017-10-01

    The Star Excursion Balance Test (SEBT) is commonly used to evaluate dynamic equilibrium. The Y Balance Test (Y-BT) is a shortened version of the SEBT where a Y- Balance Kit is commonly used. To date, research concerning the protocol and reliability of the SEBT and Y-BT has been conducted only for adults. The aim of the study was to assess the protocol (the necessary number of trials to stabilize the results) and reliability of the Y-BT in adolescent athletes. One-way repeated-measures analysis of variance (ANOVA) and reliability study. The sample of 38 athletes (mean age: 15.6 years) was selected from a football club. A Y-Balance test kit was applied for the evaluation of dynamic balance. The analysis used the values normalized to the relative length of the lower limbs. After six attempts, three consecutive ones achieved stability for all directions and both extremities (p > 0.05). The intraclass correlation coefficient (ICC 3,1 ), standard error of measurement and minimal detectable change values for the three attempts ranged from 0.57 to 0.82, from 3 to less than 6% and from 7.68 to 13.7%, respectively. In the study of adolescent dynamic equilibrium using the Y-BT, it is recommended to perform nine attempts (including six trial attempts and three measurements). In order to increase reliability it is recommended that the average of the three measured attempts is analysed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Reliability of intra-oral quantitative sensory testing (QST) in patients with atypical odontalgia and healthy controls - a multicentre study.

    Science.gov (United States)

    Baad-Hansen, L; Pigg, M; Yang, G; List, T; Svensson, P; Drangsholt, M

    2015-02-01

    The reliability of comprehensive intra-oral quantitative sensory testing (QST) protocol has not been examined systematically in patients with chronic oro-facial pain. The aim of the present multicentre study was to examine test-retest and interexaminer reliability of intra-oral QST measures in terms of absolute values and z-scores as well as within-session coefficients of variation (CV) values in patients with atypical odontalgia (AO) and healthy pain-free controls. Forty-five patients with AO and 68 healthy controls were subjected to bilateral intra-oral gingival QST and unilateral extratrigeminal QST (thenar) on three occasions (twice on 1 day by two different examiners and once approximately 1 week later by one of the examiners). Intra-class correlation coefficients and kappa values for interexaminer and test-retest reliability were computed. Most of the standardised intra-oral QST measures showed fair to excellent interexaminer (9-12 of 13 measures) and test-retest (7-11 of 13 measures) reliability. Furthermore, no robust differences in reliability measures or within-session variability (CV) were detected between patients with AO and the healthy reference group. These reliability results in chronic orofacial pain patients support earlier suggestions based on data from healthy subjects that intra-oral QST is sufficiently reliable for use as a part of a comprehensive evaluation of patients with somatosensory disturbances or neuropathic pain in the trigeminal region. © 2014 John Wiley & Sons Ltd.

  19. Balance Assessment in Sports-Related Concussion: Evaluating Test-Retest Reliability of the Equilibrate System.

    Science.gov (United States)

    Odom, Mitchell J; Lee, Young M; Zuckerman, Scott L; Apple, Rachel P; Germanos, Theodore; Solomon, Gary S; Sills, Allen K

    2016-01-01

    This study evaluated the test-retest reliability of a novel computer-based, portable balance assessment tool, the Equilibrate System (ES), used to diagnose sports-related concussion. Twenty-seven students participated in ES testing consisting of three sessions over 4 weeks. The modified Balance Error Scoring System was performed. For each participant, test-retest reliability was established using the intraclass correlation coefficient (ICC). The ES test-retest reliability from baseline to week 2 produced an ICC value of 0.495 (95% CI, 0.123-0.745). Week 2 testing produced ICC values of 0.602 (95% CI, 0.279-0.803) and 0.610 (95% CI, 0.299-0.804), respectively. All other single measures test-retest reliability values produced poor ICC values. Same-day ES testing showed fair to good test-retest reliability while interweek measures displayed poor to fair test-retest reliability. Testing conditions should be controlled when using computerized balance assessment methods. ES testing should only be used as a part of a comprehensive assessment.

  20. Assessment of Advanced Life Support competence when combining different test methods--reliability and validity

    DEFF Research Database (Denmark)

    Ringsted, C; Lippert, F; Hesselfeldt, R

    2007-01-01

    Cardiac Arrest Simulation Test (CASTest) scenarios for the assessments according to guidelines 2005. AIMS: To analyse the reliability and validity of the individual sub-tests provided by ERC and to find a combination of MCQ and CASTest that provides a reliable and valid single effect measure of ALS...... that possessed high reliability, equality of test sets, and ability to discriminate between the two groups of supposedly different ALS competence. CONCLUSIONS: ERC sub-tests of ALS competence possess sufficient reliability and validity. A combined ALS score with equal weighting of one MCQ and one CASTest can...... competence. METHODS: Two groups of participants were included in this randomised, controlled experimental study: a group of newly graduated doctors, who had not taken the ALS course (N=17) and a group of students, who had passed the ALS course 9 months before the study (N=16). Reliability in terms of inter...

  1. A fracture mechanics and reliability based method to assess non-destructive testings for pressure vessels

    International Nuclear Information System (INIS)

    Kitagawa, Hideo; Hisada, Toshiaki

    1979-01-01

    Quantitative evaluation has not been made on the effects of carrying out preservice and in-service nondestructive tests for securing the soundness, safety and maintainability of pressure vessels, spending large expenses and labor. Especially the problems concerning the time and interval of in-service inspections lack the reasonable, quantitative evaluation method. In this paper, the problems of pressure vessels are treated by having developed the analysis method based on reliability technology and probability theory. The growth of surface cracks in pressure vessels was estimated, using the results of previous studies. The effects of nondestructive inspection on the defects in pressure vessels were evaluated, and the influences of many factors, such as plate thickness, stress, the accuracy of inspection and so on, on the effects of inspection, and the method of evaluating the inspections at unequal intervals were investigated. The analysis of reliability taking in-service inspection into consideration, the evaluation of in-service inspection and other affecting factors through the typical examples of analysis, and the review concerning the time of inspection are described. The method of analyzing the reliability of pressure vessels, considering the growth of defects and preservice and in-service nondestructive tests, was able to be systematized so as to be practically usable. (Kako, I.)

  2. AMSTERDAM-NIJMEGEN EVERYDAY LANGUAGE TEST - CONSTRUCTION, RELIABILITY AND VALIDITY

    NARCIS (Netherlands)

    BLOMERT, L; KEAN, ML; KOSTER, C; SCHOKKER, J

    1994-01-01

    The Amsterdam-Nijmegen Everyday Language Test (ANELT) is designed to measure, first, the level of verbal communicative abilities of aphasic patients and, second, changes in these abilities over time. The level of communicative effectiveness is determined by the adequacy of bringing a message across.

  3. Obtaining reliable Likelihood Ratio tests from simulated likelihood functions

    DEFF Research Database (Denmark)

    Andersen, Laura Mørch

    It is standard practice by researchers and the default option in many statistical programs to base test statistics for mixed models on simulations using asymmetric draws (e.g. Halton draws). This paper shows that when the estimated likelihood functions depend on standard deviations of mixed param...

  4. The role of test-retest reliability in measuring individual and group differences in executive functioning.

    Science.gov (United States)

    Paap, Kenneth R; Sawi, Oliver

    2016-12-01

    Studies testing for individual or group differences in executive functioning can be compromised by unknown test-retest reliability. Test-retest reliabilities across an interval of about one week were obtained from performance in the antisaccade, flanker, Simon, and color-shape switching tasks. There is a general trade-off between the greater reliability of single mean RT measures, and the greater process purity of measures based on contrasts between mean RTs in two conditions. The individual differences in RT model recently developed by Miller and Ulrich was used to evaluate the trade-off. Test-retest reliability was statistically significant for 11 of the 12 measures, but was of moderate size, at best, for the difference scores. The test-retest reliabilities for the Simon and flanker interference scores were lower than those for switching costs. Standard practice evaluates the reliability of executive-functioning measures using split-half methods based on data obtained in a single day. Our test-retest measures of reliability are lower, especially for difference scores. These reliability measures must also take into account possible day effects that classical test theory assumes do not occur. Measures based on single mean RTs tend to have acceptable levels of reliability and convergent validity, but are "impure" measures of specific executive functions. The individual differences in RT model shows that the impurity problem is worse than typically assumed. However, the "purer" measures based on difference scores have low convergent validity that is partly caused by deficiencies in test-retest reliability. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Korean round-robin result for new international program to assess the reliability of emerging nondestructive techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Cho; Kim, Jin Gyum; Kang, Sung Sik; Jhung, Myung Jo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2017-04-15

    The Korea Institute of Nuclear Safety, as a representative organization of Korea, in February 2012 participated in an international Program to Assess the Reliability of Emerging Nondestructive Techniques initiated by the U.S. Nuclear Regulatory Commission. The goal of the Program to Assess the Reliability of Emerging Nondestructive Techniques is to investigate the performance of emerging and prospective novel nondestructive techniques to find flaws in nickel-alloy welds and base materials. In this article, Korean round-robin test results were evaluated with respect to the test blocks and various nondestructive examination techniques. The test blocks were prepared to simulate large-bore dissimilar metal welds, small-bore dissimilar metal welds, and bottom-mounted instrumentation penetration welds in nuclear power plants. Also, lessons learned from the Korean round-robin test were summarized and discussed.

  6. Test-retest and interrater reliability of the functional lower extremity evaluation.

    Science.gov (United States)

    Haitz, Karyn; Shultz, Rebecca; Hodgins, Melissa; Matheson, Gordon O

    2014-12-01

    Repeated-measures clinical measurement reliability study. To establish the reliability and face validity of the Functional Lower Extremity Evaluation (FLEE). The FLEE is a 45-minute battery of 8 standardized functional performance tests that measures 3 components of lower extremity function: control, power, and endurance. The reliability and normative values for the FLEE in healthy athletes are unknown. A face validity survey for the FLEE was sent to sports medicine personnel to evaluate the level of importance and frequency of clinical usage of each test included in the FLEE. The FLEE was then administered and rated for 40 uninjured athletes. To assess test-retest reliability, each athlete was tested twice, 1 week apart, by the same rater. To assess interrater reliability, 3 raters scored each athlete during 1 of the testing sessions. Intraclass correlation coefficients were used to assess the test-retest and interrater reliability of each of the FLEE tests. In the face validity survey, the FLEE tests were rated as highly important by 58% to 71% of respondents but frequently used by only 26% to 45% of respondents. Interrater reliability intraclass correlation coefficients ranged from 0.83 to 1.00, and test-retest reliability ranged from 0.71 to 0.95. The FLEE tests are considered clinically important for assessing lower extremity function by sports medicine personnel but are underused. The FLEE also is a reliable assessment tool. Future studies are required to determine if use of the FLEE to make return-to-play decisions may reduce reinjury rates.

  7. Reliability and validity of the new Tanaka B Intelligence Scale scores: a group intelligence test.

    Directory of Open Access Journals (Sweden)

    Yota Uno

    Full Text Available OBJECTIVE: The present study evaluated the reliability and concurrent validity of the new Tanaka B Intelligence Scale, which is an intelligence test that can be administered on groups within a short period of time. METHODS: The new Tanaka B Intelligence Scale and Wechsler Intelligence Scale for Children-Third Edition were administered to 81 subjects (mean age ± SD 15.2 ± 0.7 years residing in a juvenile detention home; reliability was assessed using Cronbach's alpha coefficient, and concurrent validity was assessed using the one-way analysis of variance intraclass correlation coefficient. Moreover, receiver operating characteristic analysis for screening for individuals who have a deficit in intellectual function (an FIQ<70 was performed. In addition, stratum-specific likelihood ratios for detection of intellectual disability were calculated. RESULTS: The Cronbach's alpha for the new Tanaka B Intelligence Scale IQ (BIQ was 0.86, and the intraclass correlation coefficient with FIQ was 0.83. Receiver operating characteristic analysis demonstrated an area under the curve of 0.89 (95% CI: 0.85-0.96. In addition, the stratum-specific likelihood ratio for the BIQ≤65 stratum was 13.8 (95% CI: 3.9-48.9, and the stratum-specific likelihood ratio for the BIQ≥76 stratum was 0.1 (95% CI: 0.03-0.4. Thus, intellectual disability could be ruled out or determined. CONCLUSION: The present results demonstrated that the new Tanaka B Intelligence Scale score had high reliability and concurrent validity with the Wechsler Intelligence Scale for Children-Third Edition score. Moreover, the post-test probability for the BIQ could be calculated when screening for individuals who have a deficit in intellectual function. The new Tanaka B Intelligence Test is convenient and can be administered within a variety of settings. This enables evaluation of intellectual development even in settings where performing intelligence tests have previously been difficult.

  8. Test-Retest Reliability of a Serious Game for Delirium Screening in the Emergency Department.

    Science.gov (United States)

    Tong, Tiffany; Chignell, Mark; Tierney, Mary C; Lee, Jacques S

    2016-01-01

    Introduction: Cognitive screening in settings such as emergency departments (ED) is frequently carried out using paper-and-pencil tests that require administration by trained staff. These assessments often compete with other clinical duties and thus may not be routinely administered in these busy settings. Literature has shown that the presence of cognitive impairments such as dementia and delirium are often missed in older ED patients. Failure to recognize delirium can have devastating consequences including increased mortality (Kakuma et al., 2003). Given the demands on emergency staff, an automated cognitive test to screen for delirium onset could be a valuable tool to support delirium prevention and management. In earlier research we examined the concurrent validity of a serious game, and carried out an initial assessment of its potential as a delirium screening tool (Tong et al., 2016). In this paper, we examine the test-retest reliability of the game, as it is an important criterion in a cognitive test for detecting risk of delirium onset. Objective: To demonstrate the test-retest reliability of the screening tool over time in a clinical sample of older emergency patients. A secondary objective is to assess whether there are practice effects that might make game performance unstable over repeated presentations. Materials and Methods: Adults over the age of 70 were recruited from a hospital ED. Each patient played our serious game in an initial session soon after they arrived in the ED, and in follow up sessions conducted at 8-h intervals (for each participant there were up to five follow up sessions, depending on how long the person stayed in the ED). Results: A total of 114 adults (61 females, 53 males) between the ages of 70 and 104 years ( M = 81 years, SD = 7) participated in our study after screening out delirious patients. We observed a test-retest reliability of the serious game (as assessed by correlation r -values) between 0.5 and 0.8 across adjacent

  9. Inter-tester reliability of selected clinical tests for long-lasting temporomandibular disorders.

    Science.gov (United States)

    Julsvoll, Elisabeth Heggem; Vøllestad, Nina Køpke; Opseth, Gro; Robinson, Hilde Stendal

    2017-09-01

    Clinical tests used to examine patients with temporomandibular disorders vary in methodological quality, and some are not tested for reliability. The purpose of this cross-sectional study was to evaluate inter-tester reliability of clinical tests and a cluster of tests used to examine patients with long-lasting temporomandibular disorders. Forty patients with pain in the temporomandibular area treated by health-professionals were included. They were between 18-70 years, had 65 symptomatic (33 right/32 left) and 15 asymptomatic joints. Two manual therapists examined all participants with selected tests. Percentage agreement and the kappa coefficient ( k ) with 95% confidence interval (CI) were used to evaluate the tests with categorical outcomes. For tests with continuous outcomes, the relative inter-tester reliability was assessed by the intraclass-correlation-coefficient (ICC 3,1 , 95% CI) and the absolute reliability was calculated by the smallest detectable change (SDC). The best reliability among single tests was found for the dental stick test, the joint-sound test ( k  = 0.80-1.0) and range of mouth-opening (ICC 3,1 (95% CI) = 0.97 (0.95-0.98) and SDC = 4 mm). The reliability of cluster of tests was excellent with both four and five positive tests out of seven. The reliability was good to excellent for the clinical tests and the cluster of tests when performed by experienced therapists. The tests are feasible for use in the clinical setting. They require no advanced equipment and are easy to perform.

  10. Results of a Demonstration Assessment of Passive System Reliability Utilizing the Reliability Method for Passive Systems (RMPS)

    Energy Technology Data Exchange (ETDEWEB)

    Bucknor, Matthew; Grabaskas, David; Brunett, Acacia; Grelle, Austin

    2015-04-26

    Advanced small modular reactor designs include many advantageous design features such as passively driven safety systems that are arguably more reliable and cost effective relative to conventional active systems. Despite their attractiveness, a reliability assessment of passive systems can be difficult using conventional reliability methods due to the nature of passive systems. Simple deviations in boundary conditions can induce functional failures in a passive system, and intermediate or unexpected operating modes can also occur. As part of an ongoing project, Argonne National Laboratory is investigating various methodologies to address passive system reliability. The Reliability Method for Passive Systems (RMPS), a systematic approach for examining reliability, is one technique chosen for this analysis. This methodology is combined with the Risk-Informed Safety Margin Characterization (RISMC) approach to assess the reliability of a passive system and the impact of its associated uncertainties. For this demonstration problem, an integrated plant model of an advanced small modular pool-type sodium fast reactor with a passive reactor cavity cooling system is subjected to a station blackout using RELAP5-3D. This paper discusses important aspects of the reliability assessment, including deployment of the methodology, the uncertainty identification and quantification process, and identification of key risk metrics.

  11. Reliability of Single-Leg Balance and Landing Tests in Rugby Union; Prospect of Using Postural Control to Monitor Fatigue.

    Science.gov (United States)

    Troester, Jordan C; Jasmin, Jason G; Duffield, Rob

    2018-06-01

    The present study examined the inter-trial (within test) and inter-test (between test) reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA). Twenty-four players undertook test - re-test measures on two occasions (7 days apart) on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13%) for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13%) was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%). Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%). Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%). Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union.

  12. Reliability of Single-Leg Balance and Landing Tests in Rugby Union; Prospect of Using Postural Control to Monitor Fatigue

    Directory of Open Access Journals (Sweden)

    Jordan C. Troester, Jason G. Jasmin, Rob Duffield

    2018-06-01

    Full Text Available The present study examined the inter-trial (within test and inter-test (between test reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA. Twenty-four players undertook test – re-test measures on two occasions (7 days apart on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13% for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13% was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%. Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%. Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%. Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union.

  13. Acknowledging the results of blood tests

    DEFF Research Database (Denmark)

    Torkilsheyggi, Arnvør Martinsdottir á; Hertzum, Morten

    At the studied hospital, physicians from the Medical and Surgical Departments work some of their shifts in the Emergency Department (ED). Though icons showing the blood-test process were introduced on electronic whiteboards in the ED, these icons did not lead to increased attention to test acknow...... acknowledgement. Rather, the physicians, trans-ferred work practices from their own departments, which did not have electronic white-boards, to the ED. This finding suggests a challenge to the cross-disciplinary work and norms for how to follow up on blood-test results in the ED....

  14. Practice effects and test-re-test reliability of the Five Digit Test in patients with stroke over four serial assessments.

    Science.gov (United States)

    Chiu, En-Chi; Koh, Chia-Lin; Tsai, Chia-Yin; Lu, Wen-Shian; Sheu, Ching-Fan; Hsueh, I-Ping; Hsieh, Ching-Lin

    2014-01-01

    To investigate practice effect and test-re-test reliability of the Five Digit Test (FDT) over four serial assessments in patients with stroke. Single-group repeated measures design. Twenty-five patients with stroke were administered the FDT in four consecutive assessments every 2 weeks. The FDT contains four parts with five indices: 'basic measures of attention and processing speed', 'selective attention', 'alternating attention', 'ability of inhibition' and 'ability of switching'. The five indices of the FDT showed trivial-to-small practice effects (Cohen's d = 0.03-0.47) and moderate-to-excellent test-re-test reliability (intra-class correlation coefficient = 0.59-0.97). Practice effects of the five indices all appeared cumulative, but one index, 'basic measures of attention and processing speed', reached a plateau after the second assessment. The minimum and maximum values of the 90% confidence interval (CI) of reliable change index modified for practice (RCIp) for this index were [-17.6, 11.2]. One of five indices of the FDT reached a plateau, whose minimum and maximum values of the 90% CI RCIp are useful to determine whether the change in an individual's score is real. However, clinicians and researchers should be cautious when interpreting the test results of these four indices over repeated assessments.

  15. Results of the EC research project REQUEST on software quality and reliability

    International Nuclear Information System (INIS)

    Kersken, M.; Saglietti, F.

    1990-01-01

    GRS work in software safety was mainly concerned with the qualitative assessment of software reliability and quality. As a supplement to these activities the work within the REQUEST project emphasized the quantitative determination of the respective parameters. The three-level quality model COQUAMO serves for the computation - and partly for the prediction - of quality factors during the software life cycle. PERFIDE controls the application of software reliability models during the test phase and in early operational life. Specific attention was paid to the assessment of fault-tolerant diverse software systems. (orig.) [de

  16. Improving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep.

    Science.gov (United States)

    Wang, Jiahui; Han, Junwei; Nguyen, Vinh T; Guo, Lei; Guo, Christine C

    2017-01-01

    Resting state functional magnetic resonance imaging (rs-fMRI) provides a powerful tool to examine large-scale neural networks in the human brain and their disturbances in neuropsychiatric disorders. Thanks to its low demand and high tolerance, resting state paradigms can be easily acquired from clinical population. However, due to the unconstrained nature, resting state paradigm is associated with excessive head movement and proneness to sleep. Consequently, the test-retest reliability of rs-fMRI measures is moderate at best, falling short of widespread use in the clinic. Here, we characterized the effect of sleep on the test-retest reliability of rs-fMRI. Using measures of heart rate variability (HRV) derived from simultaneous electrocardiogram (ECG) recording, we identified portions of fMRI data when subjects were more alert or sleepy, and examined their effects on the test-retest reliability of functional connectivity measures. When volumes of sleep were excluded, the reliability of rs-fMRI is significantly improved, and the improvement appears to be general across brain networks. The amount of improvement is robust with the removal of as much as 60% volumes of sleepiness. Therefore, test-retest reliability of rs-fMRI is affected by sleep and could be improved by excluding volumes of sleepiness as indexed by HRV. Our results suggest a novel and practical method to improve test-retest reliability of rs-fMRI measures.

  17. Improving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep

    Directory of Open Access Journals (Sweden)

    Jiahui Wang

    2017-05-01

    Full Text Available Resting state functional magnetic resonance imaging (rs-fMRI provides a powerful tool to examine large-scale neural networks in the human brain and their disturbances in neuropsychiatric disorders. Thanks to its low demand and high tolerance, resting state paradigms can be easily acquired from clinical population. However, due to the unconstrained nature, resting state paradigm is associated with excessive head movement and proneness to sleep. Consequently, the test-retest reliability of rs-fMRI measures is moderate at best, falling short of widespread use in the clinic. Here, we characterized the effect of sleep on the test-retest reliability of rs-fMRI. Using measures of heart rate variability (HRV derived from simultaneous electrocardiogram (ECG recording, we identified portions of fMRI data when subjects were more alert or sleepy, and examined their effects on the test-retest reliability of functional connectivity measures. When volumes of sleep were excluded, the reliability of rs-fMRI is significantly improved, and the improvement appears to be general across brain networks. The amount of improvement is robust with the removal of as much as 60% volumes of sleepiness. Therefore, test-retest reliability of rs-fMRI is affected by sleep and could be improved by excluding volumes of sleepiness as indexed by HRV. Our results suggest a novel and practical method to improve test-retest reliability of rs-fMRI measures.

  18. The Ostomy Adjustment Scale: translation into Norwegian language with validation and reliability testing.

    Science.gov (United States)

    Indrebø, Kirsten Lerum; Andersen, John Roger; Natvig, Gerd Karin

    2014-01-01

    The purpose of this study was to adapt the Ostomy Adjustment Scale to a Norwegian version and to assess its construct validity and 2 components of its reliability (internal consistency and test-retest reliability). One hundred fifty-eight of 217 patients (73%) with a colostomy, ileostomy, or urostomy participated in the study. Slightly more than half (56%) were men. Their mean age was 64 years (range, 26-91 years). All respondents had undergone ostomy surgery at least 3 months before participation in the study. The Ostomy Adjustment Scale was translated into Norwegian according to standard procedures for forward and backward translation. The questionnaire was sent to the participants via regular post. The Cronbach alpha and test-retest were computed to assess reliability. Construct validity was evaluated via correlations between each item and score sums; correlations were used to analyze relationships between the Ostomy Adjustment Scale and the 36-item Short Form Health Survey, the Quality of Life Scale, the Hospital Anxiety & Depression Scale, and the General Self-Efficacy Scale. The Cronbach alpha was 0.93, and test-retest reliability r was 0.69. The average correlation quotient item to sum score was 0.49 (range, 0.31-0.73). Results showed moderate negative correlations between the Ostomy Adjustment Scale and the Hospital Anxiety and Depression Scale (-0.37 and -0.40), and moderate positive correlations between the Ostomy Adjustment Scale and the 36-item Short Form Health Survey, the Quality of Life Scale, and the General Self-Efficacy Scale (0.30-0.45) with the exception of the pain domain in the Short Form 36 (0.28). Regression analysis showed linear associations between the Ostomy Adjustment Scale and sociodemographic and clinical variables with the exception of education. The Norwegian language version of the Ostomy Adjustment Scale was found to possess construct validity, along with internal consistency and test-retest reliability. The instrument is

  19. Design of experiments for test of fuel element reliability

    International Nuclear Information System (INIS)

    Boehmert, J.; Juettner, C.; Linek, J.

    1989-01-01

    Changes of fuel element design and modifications of the operational conditions have to be tested in experiments and pilot projects for nuclear safety. Experimental design is an useful statistical method minimizing costs and risks for this procedure. The main problem of our work was to investigate the connection between failure rate of fuel elements, sample size, confidence interval, and error probability. Using the statistic model of the binomial distribution appropriate relations were derived and discussed. A stepwise procedure based on a modified sequential analysis according to Wald was developed as a strategy of introduction for modifications of the fuel element design and of the operational conditions. (author)

  20. Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

    Science.gov (United States)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.

    2010-01-01

    Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

  1. The validity and reliability of a dynamic neuromuscular stabilization-heel sliding test for core stability.

    Science.gov (United States)

    Cha, Young Joo; Lee, Jae Jin; Kim, Do Hyun; You, Joshua Sung H

    2017-10-23

    Core stabilization plays an important role in the regulation of postural stability. To overcome shortcomings associated with pain and severe core instability during conventional core stabilization tests, we recently developed the dynamic neuromuscular stabilization-based heel sliding (DNS-HS) test. The purpose of this study was to establish the criterion validity and test-retest reliability of the novel DNS-HS test. Twenty young adults with core instability completed both the bilateral straight leg lowering test (BSLLT) and DNS-HS test for the criterion validity study and repeated the DNS-HS test for the test-retest reliability study. Criterion validity was determined by comparing hip joint angle data that were obtained from BSLLT and DNS-HS measures. The test-retest reliability was determined by comparing hip joint angle data. Criterion validity was (ICC2,3) = 0.700 (preliability was (ICC3,3) = 0.953 (pvalidity data demonstrated a good relationship between the gold standard BSLLT and DNS-HS core stability measures. Test-retest reliability data suggests that DNS-HS core stability was a reliable test for core stability. Clinically, the DNS-HS test is useful to objectively quantify core instability and allow early detection and evaluation.

  2. Validity and reliability of new agility test among elite and subelite under 14-soccer players.

    Directory of Open Access Journals (Sweden)

    Younés Hachana

    Full Text Available BACKGROUND: Agility is a determinant component in soccer performance. This study aimed to evaluate the reliability and sensitivity of a "Modified Illinois change of direction test" (MICODT in ninety-five U-14 soccer players. METHODS: A total of 95 U-14 soccer players (mean ± SD: age: 13.61 ± 1.04 years; body mass: 30.52 ± 4.54 kg; height: 1.57 ± 0.1 m from a professional and semi-professional soccer academy, participated to this study. Sixty of them took part in reliability analysis and thirty-two in sensitivity analysis. RESULTS: The intraclass correlation coefficient (ICC that aims to assess relative reliability of the MICODT was of 0.99, and its standard error of measurement (SEM for absolute reliability was <5% (1.24%. The MICODT's capacity to detect change is "good", it's SEM (0.10 s was ≤ SWC (0.33 s. The MICODT is significantly correlated to the Illinois change of direction speed test (ICODT (r = 0.77; p<0.0001. The ICODT's MDC95 (0.64 s was twice about the MICODT's MDC95 (0.28 s, indicating that MICODT presents better ability to detect true changes than ICODT. The MICODT provided good sensitivity since elite U-14 soccer players were better than non-elite one on MICODT (p = 0.005; dz = 1.01 [large]. This was supported by an area under the ROC curve of 0.77 (CI 95%, 0.59 to 0.89, p<0.0008. The difference observed in these two groups in ICODT was not statistically significant (p = 0.14; dz = 0.51 [small], showing poor discriminant ability. CONCLUSION: MICODT can be considered as more suitable protocol for assessing agility performance level than ICODT in U-14 soccer players.

  3. High-Speed Shaft Bearing Loads Testing and Modeling in the NREL Gearbox Reliability Collaborative: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    McNiff, B.; Guo, Y.; Keller, J.; Sethuraman, L.

    2014-12-01

    Bearing failures in the high speed output stage of the gearbox are plaguing the wind turbine industry. Accordingly, the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) has performed an experimental and theoretical investigation of loads within these bearings. The purpose of this paper is to describe the instrumentation, calibrations, data post-processing and initial results from this testing and modeling effort. Measured HSS torque, bending, and bearing loads are related to model predictions. Of additional interest is examining if the shaft measurements can be simply related to bearing load measurements, eliminating the need for invasive modifications of the bearing races for such instrumentation.

  4. Test anxiety inventory-State: Preliminary analysis of validity and reliability in psychology college students

    Directory of Open Access Journals (Sweden)

    Sergio Dominguez-Lara

    2016-12-01

    Full Text Available The objective of the present study was to examine the internal structure of the Test anxiety inventory-State (TAI-State in Spanish version. A sample of 125 college students from Lima (84.8% female between 18 and 31 years old (M = 22.51 was evaluated. The internal structure of the STAI was analyzed by a confirmatory factor analysis, evaluating three models: oblique, bifactor and unidimensional. The results indicate that a single dimension constitutes the STAI and there are coefficients of reliability with high magnitudes. In conclusion, the version studied shows favorable psychometric properties that support its use in Lima.

  5. Test-Retest Reliability and Practice Effects of the Stability Evaluation Test.

    Science.gov (United States)

    Williams, Richelle M; Corvo, Matthew A; Lam, Kenneth C; Williams, Travis A; Gilmer, Lesley K; McLeod, Tamara C Valovich

    2017-01-17

    Postural control plays an essential role in concussion evaluation. The Stability Evaluation Test (SET) aims to objectively analyze postural control by measuring sway velocity on the NeuroCom's VSR portable force platform (Natus, San Carlos, CA). To assess the test-retest reliability and practice effects of the SET protocol. Cohort. Research Laboratory. Fifty healthy adults (males=20, females=30, age=25.30±3.60 years, height=166.60±12.80 cm, mass=68.80±13.90 kg). All participants completed four trials of the SET. Each trial consisted of six 20-second balance tests with eyes closed, under the following conditions: double-leg firm (DFi), single-leg firm (SFi), tandem firm (TFi), double-leg foam (DFo), single-leg foam (SFo), and tandem foam (TFo). Each trial was separated by a 5-minute seated rest period. The dependent variable was sway velocity (deg/sec), with lower values indicating better balance. Sway velocity was recorded for each of the six conditions as well as a composite score for each trial. Test-retest reliability was analyzed across four trials with Intraclass Correlation Coefficients. Practice effects analyzed with repeated measures analysis of variance, followed by Tukey post-hoc comparisons for any significant main effects (preliability values were good to excellent: DFi (ICC=0.88;95%CI:0.81,0.92), SFi (ICC=0.75;95%CI:0.61,0.85), TFi (ICC=0.84;95%CI:0.75,0.90), DFo (ICC=0.83;95%CI:0.74,0.90), SFo (ICC=0.82;95%CI:0.72,0.89), TFo (ICC=0.81;95%CI:0.69,0.88), and composite score (ICC=0.93;95%CI:0.88,0.95). Significant practice effects (preliability for the assessment of postural control in healthy adults. Due to the practice effects noted, a familiarization session is recommended (i.e., all 6 conditions) prior to recording the data. Future studies should evaluate injured patients to determine meaningful change scores during various injuries.

  6. The new features of the ExaMe evaluation system and reliability of its fixed tests.

    Science.gov (United States)

    Martinková, P; Zvára, K; Zvárová, J; Zvára, K

    2006-01-01

    The ExaMe system for the evaluation of targeted knowledge has been in development since 1998. The new features of the ExaMe system are introduced in this paper. Especially, the new three-layer architecture is described. Besides the system itself, the properties of fixed tests in the ExaMe system are studied. In special detail, the reliability of the fixed tests is discussed. The theory background is explained and some limitations of the reliability are pointed out. Three characteristics used for estimation of reliability of educational tests are discussed: Cronbach's alpha, standardized item alpha and split half coefficient. The relation between these characteristics and reliability and between characteristics themselves is investigated. In more detail, the properties of Cronbach's alpha, the characteristics mostly used for the estimation of reliability, are discussed. A confidence interval is introduced for the characteristics. Since 2000, the serviceability of the ExaMe evaluation system as the supporting evaluation tool has been repeatedly shown at the courses of Ph.D. studies in biomedical informatics at Charles University in Prague. The ExaMe system also opens new possibilities for self-evaluation and distance learning, especially when connected with electronic books on the Internet. The estimation of reliability of tests contains some limitations. Keeping them in mind, we can still get some information about the quality of certain educational tests. Therefore, the estimation of reliability of the fixed tests is implemented in the ExaMe system.

  7. Effects of Analytical and Holistic Scoring Patterns on Scorer Reliability in Biology Essay Tests

    Science.gov (United States)

    Ebuoh, Casmir N.

    2018-01-01

    Literature revealed that the patterns/methods of scoring essay tests had been criticized for not being reliable and this unreliability is more likely to be more in internal examinations than in the external examinations. The purpose of this study is to find out the effects of analytical and holistic scoring patterns on scorer reliability in…

  8. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease

    NARCIS (Netherlands)

    Strouwen, C.; Molenaar, E.A.; Keus, S.H.; Munks, L.; Bloem, B.R.; Nieuwboer, A.

    2016-01-01

    BACKGROUND: Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains

  9. Reasoning with Inductive Argument Test: A Study of Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Mehmet Emrah Karadere

    2013-12-01

    Conclusion: The preliminary data obtained from the study of reliability and validity of the scale shows that ‘Reasoning with Inductive Argument Test’ supports reliability and validity in Turkish population. [JCBPR 2013; 2(3.000: 156-161

  10. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    Science.gov (United States)

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which

  11. Recumbent Stepper Submaximal Test response is reliable in adults with and without stroke.

    Directory of Open Access Journals (Sweden)

    David R Wilson

    Full Text Available The purpose of the present study was to determine the reliability of the exercise response (predicted peak VO2 using the total body recumbent stepper (TBRS submaximal exercise test in: 1 healthy adults 20-70 years of age and 2 adults participating in inpatient stroke rehabilitation. We hypothesized that the predicted peak VO2 (Visit 1 would have an excellent relationship (r > 0.80 to predicted peak VO2 (Visit 2. We also wanted to test whether the exercise response at Visit 1 and Visit 2 would be significantly different.Healthy adults were recruited from the Kansas City metro area. Stroke participants were recruited during their inpatient rehabilitation stay. Eligible participants completed 2 TBRS submaximal exercise tests between 24 hours and 5 days at similar times of day.A total of 70 participants completed the study. Healthy adults (n = 50 were 36 M, 38.1 ± 10.1 years and stroke participants (n = 20 were 15 M, 62.5 ± 11.8 years of age. The exercise response was reliable for healthy adults (r = 0.980, p<0.01 and stroke participants (r = 0.987, p<0.01 between Visit 1 and Visit 2. Repeated Measures ANOVA showed a significant difference in predicted values between the two visits for healthy adults (47.2 ± 8.4 vs 47.7 ± 8.5 mL∙kg-1∙min-1; p = 0.04 but not for stroke participants (25.0 ± 9.9 vs 25.3 ± 11.4 mL∙kg-1∙min-1; p = 0.65.These results suggest that the exercise response is reliable using the TBRS submaximal exercise test in this cohort of healthy adults and stroke participants.

  12. Development of Chinese Military Personnel Social Support Scale and tests for its reliability and validity

    Directory of Open Access Journals (Sweden)

    Kai-hong TANG

    2013-01-01

    Full Text Available Objective  To develop Chinese Military Personnel Social Support Scaleand verify its reliability and validity. Methods  The Chinese Military Personnel Social Support Scalewas initiated, organized and compiled based upon open-ended questionnaire survey done in a systematic manner, and previous researches were taken as references. A total of 630 military personnel were chosen by random cluster sampling and tested with the Scale, among them 50 were tested with Social Support Rating Scale(SSRS and Chinese Military Psychosomatic Health Scale(CMPHS simultaneously, and the test was done solely a second time with CMPHS 2 weeks later. The reliability and validity were assessed and verified by exploratory factor analysis, confirmatory factor analysis and correlation analysis. Results  The Chinese Military Personnel Social Support Scalecomprised three factors, namely subjective support, objective support and utility of social support. Eighteen items were left in official scale after amendment by factor analysis, and one lying subscale was added. The correlation coefficients between the public factors ranged from 0.477 to 0.589 (P<0.01, and the correlation coefficients between factors and total scale ranged from 0.721 to 0.823 (P<0.01. The test-retest correlation coefficients of total scale and subscales ranged from 0.622 to 0.803 (P<0.01, the Cronbach α coefficients ranged from 0.624 to 0.874, and the split-half correlation coefficients ranged from 0.551 to 0.828. Significant correlation existed between this Scale and two criterion scales, namely SSRS and CMPHS. Conclusion  It is verified that the Chinese Military Personnel Social Support Scalehas excellent reliability and validity, and complying with psychometric standards, it may be used to evaluate the social support level of Chinese military personnel.

  13. Reliability and validity of the new Tanaka B Intelligence Scale scores: a group intelligence test.

    Science.gov (United States)

    Uno, Yota; Mizukami, Hitomi; Ando, Masahiko; Yukihiro, Ryoji; Iwasaki, Yoko; Ozaki, Norio

    2014-01-01

    The present study evaluated the reliability and concurrent validity of the new Tanaka B Intelligence Scale, which is an intelligence test that can be administered on groups within a short period of time. The new Tanaka B Intelligence Scale and Wechsler Intelligence Scale for Children-Third Edition were administered to 81 subjects (mean age ± SD 15.2 ± 0.7 years) residing in a juvenile detention home; reliability was assessed using Cronbach's alpha coefficient, and concurrent validity was assessed using the one-way analysis of variance intraclass correlation coefficient. Moreover, receiver operating characteristic analysis for screening for individuals who have a deficit in intellectual function (an FIQIntelligence Scale IQ (BIQ) was 0.86, and the intraclass correlation coefficient with FIQ was 0.83. Receiver operating characteristic analysis demonstrated an area under the curve of 0.89 (95% CI: 0.85-0.96). In addition, the stratum-specific likelihood ratio for the BIQ≤65 stratum was 13.8 (95% CI: 3.9-48.9), and the stratum-specific likelihood ratio for the BIQ≥76 stratum was 0.1 (95% CI: 0.03-0.4). Thus, intellectual disability could be ruled out or determined. The present results demonstrated that the new Tanaka B Intelligence Scale score had high reliability and concurrent validity with the Wechsler Intelligence Scale for Children-Third Edition score. Moreover, the post-test probability for the BIQ could be calculated when screening for individuals who have a deficit in intellectual function. The new Tanaka B Intelligence Test is convenient and can be administered within a variety of settings. This enables evaluation of intellectual development even in settings where performing intelligence tests have previously been difficult.

  14. Test Results of PBMR Fuel Spheres

    International Nuclear Information System (INIS)

    Koshcheev, Konstantin; Diakov, Alexander; Beltyukov, Igor; Barybin, Andrey; Chernetsov, Mikhail

    2014-01-01

    Results of pre-irradiation testing of fuel spheres (FS) and coated particles (CP) manufactured by PBMR SOC (Republic of South Africa) are described. The stable high quality level of major characteristics (dimensions, CP coating structure, uranium-235 contamination of the FS matrix graphite and the outer PyC layer of the CP coating) are shown. Results of a methodical irradiation test of two FS in helium and neon medium at temperatures of 800 to 1300 °C with simultaneous determination of release-to-birth ratios for major gaseous fission products (GFP) are described. (author)

  15. Reliability, validity and usefulness of 30-15 Intermittent Fitness Test in Female Soccer Players

    Directory of Open Access Journals (Sweden)

    Nedim Čović

    2016-11-01

    Full Text Available PURPOSE: The aim of this study was to examine the reliability, validity and usefulness of the 30-15IFT in competitive female soccer players. METHODS: Seventeen elite female soccer players participated in the study. A within subject test-retest study design was utilized to assess the reliability of the 30-15 intermittent fitness test (IFT. Seven days prior to 30-15IFT, subjects performed a continuous aerobic running test (CT under laboratory conditions to assess the criterion validity of the 30-15IFT. End running velocity (VCT and VIFT, peak heart rate (HRpeak and maximal oxygen consumption (VO2max were collected and/or estimated for both tests. RESULTS: VIFT (ICC = 0.91; CV = 1.8%, HRpeak (ICC = 0.94; CV = 1.2%, and VO2max (ICC = 0.94; CV = 1.6% obtained from the 30-15IFT were all deemed highly reliable (p>0.05. Pearson product moment correlations between the CT and 30-15IFT for VO2max, HRpeak and end running velocity were large (r = 0.67, p=0.013, very large (r = 0.77, p=0.02 and large (r = 0.57, p=0.042, respectively. CONCLUSION: Current findings suggest that the 30 -15IFT is a valid and reliable intermittent aerobic fitness test of elite female soccer players. The findings have also provided practitioners with evidence to support the accurate detection of meaningful individual changes in VIFT of 0.5 km/h (1 stage and HRpeak of 2 bpm. This information may assist coaches in monitoring ‘real’ aerobic fitness changes to better inform training of female intermittent team sport athletes. Lastly, coaches could use the 30-15IFT as a practical alternative to laboratory based assessments to assess and monitor intermittent aerobic fitness changes in their athletes. Keywords: 30-15 intermittent fitness test, aerobic, cardiorespiratory fitness, intermittent activity, soccer, high intensity interval training.

  16. Enertech 2-kW high-reliability wind system. Phase II. Fabrication and testing

    Energy Technology Data Exchange (ETDEWEB)

    Cordes, J A; Johnson, B A

    1981-06-01

    A high-reliability wind machine rated for 2 kW in a 9 m/s wind has been developed. Activities are summarized that are centered on the fabrication and testing of prototypes of the wind machine. The test results verified that the wind machine met the power output specification and that the variable-pitch rotor effectively controlled the rotor speed for wind speeds up to 50 mph. Three prototypes of the wind machine were shipped to the Rocky Flats test center in September through November of 1979. Work was also performed to reduce the start-up wind speed. The start-up wind speed to the Enertech facility has been reduced to 4.5 m/s.

  17. Human and organisational factors influencing the reliability of non-destructive testing. An international literary survey

    International Nuclear Information System (INIS)

    Kettunen, J.; Norros, L.

    1996-04-01

    The aim of the study is to chart human and organisational factors influencing the reliability of non-destructive testing (NDT). The emphasis will be in ultrasonic testing (UT) and in the planning and execution of in-service inspections during nuclear power plant maintenance outages. Being a literary survey this study is mainly based on the foreign and domestic research available on the topic. In consequence, the results presented in this report reflect the ideas of international research community. In addition to this, Finnish nuclear power plant operators (Imatran Voima Oy and Teollisuuden Voima Oy), independent inspection organisations and the Finnish Centre for Radiation and Nuclear Safety have provided us with valuable information on NDT theory and practice. Especially, a kind of 'big picture' of non-destructive testing has been pursued in the study. (6 figs., 2 tabs.)

  18. A study on the reliability evaluation of shot peened aluminium alloy using accelerated life test

    International Nuclear Information System (INIS)

    Nam, Ji Hun; Cheong, Seong Kyun; Kang, Min Woo

    2006-01-01

    In this paper, the concept of accelerated life test, which is a popular research field nowadays, is applied to the shot peened material. To predict the efficient and exact room temperature fatigue characteristics from the high temperature fatigue data, the adequate accelerated model is investigated. Ono type rotary bending fatigue tester and high temperature chamber were used for the experiment. Room temperature fatigue lives were predicted by applying accelerated models and doing reliability evaluation. Room temperature fatigue tests were accomplished to check the effectiveness of predicted data and the adequate accelerated life test models were presented by considering errors. Experimental result using Arrhenius model, fatigue limit obtain almost 5.45% of error, inverse power law has about 1.36% of error, so we found that inverse power law is applied well to temperature-life relative of shot peended material

  19. Long-Term Reliability of SiGe/Si HBTs From Accelerated Lifetime Testing

    Science.gov (United States)

    Bhattacharya, Pallab

    2001-01-01

    Accelerated lifetime tests were performed on double-mesa structure Si(0.7)Ge(0.3)/Si npn heterojunction bipolar transistors, grown by molecular beam epitaxy, in the temperature range of 175 C-275 C. The transistors (with 5x20 sq micron emitter area) have DC current gains approx. 40-50 and f(sub T) and f(sub max) of up to 22 GHz and 25 GHz, respectively. It is found that a gradual degradation in these devices is caused by the recombination enhanced impurity diffusion (REID) of boron atoms from the p-type base region and the associated formation of parasitic energy barriers to electron transport from the emitter to collector layers. This REED has been quantitatively modeled and explained, to the first order of approximation, and the agreement with the measured data is good. The mean time to failure (MTTF) of these devices at room temperature under 1.35 x 10(exp 4) A/sq cm current density operation is estimated from the extrapolation of the Arrhenius plots of device lifetime versus reciprocal temperature. The results of the reliability tests offer valuable feedback for SiGe heterostructure design in order to improve the long-term reliability of the devices and circuits made with them. Hot electron induced degradation of the base-emitter junction was also observed during the accelerated lifetime testing. In order to improve the HBT reliability endangered by the hot electrons, deuterium sintered techniques have been proposed. The preliminary results from this study show that a deuterium-sintered HBT is, indeed, more resistant to hot-electron induced base-emitter junction degradation.

  20. Reliability of the test of gross motor development second edition (TGMD-2) for Kindergarten children in Myanmar.

    Science.gov (United States)

    Aye, Thanda; Oo, Khin Saw; Khin, Myo Thuzar; Kuramoto-Ahuja, Tsugumi; Maruyama, Hitoshi

    2017-10-01

    [Purpose] The purpose of this study was to investigate reliability of the test of gross motor development second edition (TGMD-2) for Kindergarten children in Myanmar. [Subjects and Methods] Fifty healthy Kindergarten children (23 males, 27 females) whose parents/guardians had given written consent were participated. The subjects were explained and demonstrated all 12 gross motor skills of TGMD-2 before the assessment. Each subject individually performed two trials for each gross motor skill and the performance was video recorded. Three raters separately watched the video recordings and rated for inter-rater reliability. The second assessment was done one month later with 25 out of 50 subjects for test-rest reliability. The video recordings of 12 subjects were randomly selected from the first 50 recordings for intra-rater reliability six weeks after the first assessment. The agreement on the locomotor and object control raw scores and the gross motor quotient (GMQ) were calculated. [Results] The findings of all the reliability coefficients for the locomotor and object control raw scores and the GMQ were interpreted as good and excellent reliability. [Conclusion] The results represented that TGMD-2 is a highly reliable and appropriate assessment tool for assessing gross motor skill development of Kindergarten children in Myanmar.

  1. Test-retest reliability of evoked BOLD signals from a cognitive-emotive fMRI test battery.

    Science.gov (United States)

    Plichta, Michael M; Schwarz, Adam J; Grimm, Oliver; Morgen, Katrin; Mier, Daniela; Haddad, Leila; Gerdes, Antje B M; Sauer, Carina; Tost, Heike; Esslinger, Christine; Colman, Peter; Wilson, Frederick; Kirsch, Peter; Meyer-Lindenberg, Andreas

    2012-04-15

    Even more than in cognitive research applications, moving fMRI to the clinic and the drug development process requires the generation of stable and reliable signal changes. The performance characteristics of the fMRI paradigm constrain experimental power and may require different study designs (e.g., crossover vs. parallel groups), yet fMRI reliability characteristics can be strongly dependent on the nature of the fMRI task. The present study investigated both within-subject and group-level reliability of a combined three-task fMRI battery targeting three systems of wide applicability in clinical and cognitive neuroscience: an emotional (face matching), a motivational (monetary reward anticipation) and a cognitive (n-back working memory) task. A group of 25 young, healthy volunteers were scanned twice on a 3T MRI scanner with a mean test-retest interval of 14.6 days. FMRI reliability was quantified using the intraclass correlation coefficient (ICC) applied at three different levels ranging from a global to a localized and fine spatial scale: (1) reliability of group-level activation maps over the whole brain and within targeted regions of interest (ROIs); (2) within-subject reliability of ROI-mean amplitudes and (3) within-subject reliability of individual voxels in the target ROIs. Results showed robust evoked activation of all three tasks in their respective target regions (emotional task=amygdala; motivational task=ventral striatum; cognitive task=right dorsolateral prefrontal cortex and parietal cortices) with high effect sizes (ES) of ROI-mean summary values (ES=1.11-1.44 for the faces task, 0.96-1.43 for the reward task, 0.83-2.58 for the n-back task). Reliability of group level activation was excellent for all three tasks with ICCs of 0.89-0.98 at the whole brain level and 0.66-0.97 within target ROIs. Within-subject reliability of ROI-mean amplitudes across sessions was fair to good for the reward task (ICCs=0.56-0.62) and, dependent on the particular ROI

  2. Clinical Functional Capacity Testing in Patients With Facioscapulohumeral Muscular Dystrophy: Construct Validity and Interrater Reliability of Antigravity Tests

    NARCIS (Netherlands)

    Rijken, N.H.M.; Engelen, B.G.M. van; Weerdesteyn, V.G.M.; Geurts, A.C.H.

    2015-01-01

    OBJECTIVE: To evaluate the construct validity and interrater reliability of 4 simple antigravity tests in a small group of patients with facioscapulohumeral muscular dystrophy (FSHD). DESIGN: Case-control study. SETTING: University medical center. PARTICIPANTS: Patients with various severity levels

  3. Bayesian analysis of heat pipe life test data for reliability demonstration testing

    International Nuclear Information System (INIS)

    Bartholomew, R.J.; Martz, H.F.

    1985-01-01

    The demonstration testing duration requirements to establish a quantitative measure of assurance of expected lifetime for heat pipes was determined. The heat pipes are candidate devices for transporting heat generated in a nuclear reactor core to thermoelectric converters for use as a space-based electric power plant. A Bayesian analysis technique is employed, utilizing a limited Delphi survey, and a geometric mean accelerated test criterion involving heat pipe power (P) and temperature (T). Resulting calculations indicate considerable test savings can be achieved by employing the method, but development testing to determine heat pipe failure mechanisms should not be circumvented

  4. ALICE TRD results from prototype tests

    CERN Document Server

    Andronic, A; Blume, C; Braun-Munzinger, P; Bucher, D; Catanescu, G; Ciobanu, M; Daues, H W; Devismes, A; Finck, C; Herrmann, N; Lister, T A; Mahmoud, Tariq; Peitzmann, Thomas; Petrovici, M; Reygers, K; Santo, R; Schicker, R; Sedykha, S; Simon, R S; Stachel, J; Stelzer, H; Wessels, J P; Winkelmann, O; Windelband, B; Xu, C

    2002-01-01

    We present results from tests of a prototype of the TRD for the ALICE experiment at LHC. We investigate the performance-of different radiator types, composed of foils, fibres and foams. The pion rejection performance for different methods of analysis over a momentum range from 0.7 to 2 GeV/c is presented. (8 refs).

  5. SLD liquid argon calorimeter prototype test results

    International Nuclear Information System (INIS)

    Dubois, R.; Eigen, G.; Au, Y.

    1985-10-01

    The results of the SLD test beam program for the selection of a calorimeter radiator composition within a liquid argon system are described, with emphasis on the study of the use of uranium to obtain equalization of pion and electron responses

  6. Cone Penetrometer N Factor Determination Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Follett, Jordan R.

    2014-03-05

    This document contains the results of testing activities to determine the empirical 'N Factor' for the cone penetrometer in kaolin clay simulant. The N Factor is used to releate resistance measurements taken with the cone penetrometer to shear strength.

  7. Ball Aerospace SBMD Coating Test Results

    Science.gov (United States)

    Brown, Robert; Lightsey, Paul; Russell, J. Kevin (Technical Monitor)

    2002-01-01

    The Sub-scale Beryllium Mirror Demonstrator that was successfully tested to demonstrate cryogenic figuring of a bare mirror has been coated with a protected gold reflective surface and retested at cryogenic temperatures. Results showing less than 9 nm rms surface distortion attributable to the added coating are presented.

  8. Accreditation and radiation protection - the cost or smaller doses and reliable results

    International Nuclear Information System (INIS)

    Omahen, G.; Zdesar, U.

    2011-01-01

    Laboratories involved in the protection against radiation and therefore in the measurement of radioactivity, dose rate and contamination have always been tied to the quality of their measurements, particularly those that have performed measurements for nuclear power plants. However in the laboratories more than quality it was more important, that people are professional, that they are engaged in scientific work and know how to interpret the results. Very often these are things that do not go along with reviewing the measuring instruments and quality records. However customer requires measurement results that can be trusted. This is the purpose of the standard SIST EN ISO / IEC 17025 in which the requirements for testing and calibration laboratories are standardised. The standard in force since 1999. In some countries, requests for accreditation of testing laboratories according to SIST EN ISO / IEC 17025 is even in regulation. This request is for example in the Croatian and Slovenian regulations for laboratories involved in measuring the radioactivity, dose rate, contamination, or by checking the X-ray apparatus. Several laboratories have been accreditation for several years. From that experience we can conclude that customer gets reliable results from the accredited laboratories at relatively low cost. On the other side laboratory which his accredited has introduced a line of work and his laboratory, there are rules for equipment, personnel, training and all that eventually enhanced measurement expertise. With accreditation, it is much easier to compensate for the loss of workers due to pension or leaving the laboratory because every moment must always be in the laboratory at least two who know how to work on the method. Accreditation is not improving radiation protection or reducing Becquerel in the air. But at least we know how accurate mSv or Bq are and how small mSv and Bq can be measured. (author) [sr

  9. Establishing a 'Physician's Spiritual Well-being Scale' and testing its reliability and validity.

    Science.gov (United States)

    Fang, C K; Li, P Y; Lai, M L; Lin, M H; Bridge, D T; Chen, H W

    2011-01-01

    The purpose of this study was to develop a Physician's Spiritual Well-Being Scale (PSpWBS). The significance of a physician's spiritual well-being was explored through in-depth interviews with and qualitative data collection from focus groups. Based on the results of qualitative analysis and related literature, the PSpWBS consisting of 25 questions was established. Reliability and validity tests were performed on 177 subjects. Four domains of the PSpWBS were devised: physician's characteristics; medical practice challenges; response to changes; and overall well-being. The explainable total variance was 65.65%. Cronbach α was 0.864 when the internal consistency of the whole scale was calculated. Factor analysis showed that the internal consistency Cronbach α value for each factor was between 0.625 and 0.794 and the split-half reliability was 0.865. The scale has satisfactory reliability and validity and could serve as the basis for assessment of the spiritual well-being of a physician.

  10. Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment. Research project

    International Nuclear Information System (INIS)

    Martorell, S.; Serradell, V.; Munoz, A.; Sanchez, A.

    1997-01-01

    Background, objective, scope, detailed working plan and follow-up and final product of the project ''Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment'' are described

  11. Educational testing validity and reliability in pharmacy and medical education literature.

    Science.gov (United States)

    Hoover, Matthew J; Jung, Rose; Jacobs, David M; Peeters, Michael J

    2013-12-16

    To evaluate and compare the reliability and validity of educational testing reported in pharmacy education journals to medical education literature. Descriptions of validity evidence sources (content, construct, criterion, and reliability) were extracted from articles that reported educational testing of learners' knowledge, skills, and/or abilities. Using educational testing, the findings of 108 pharmacy education articles were compared to the findings of 198 medical education articles. For pharmacy educational testing, 14 articles (13%) reported more than 1 validity evidence source while 83 articles (77%) reported 1 validity evidence source and 11 articles (10%) did not have evidence. Among validity evidence sources, content validity was reported most frequently. Compared with pharmacy education literature, more medical education articles reported both validity and reliability (59%; particles in pharmacy education compared to medical education, validity, and reliability reporting were limited in the pharmacy education literature.

  12. Reliability of physical functioning tests in patients with low back pain: a systematic review.

    Science.gov (United States)

    Denteneer, Lenie; Van Daele, Ulrike; Truijen, Steven; De Hertogh, Willem; Meirte, Jill; Stassijns, Gaetane

    2018-01-01

    The aim of this study was to provide a comprehensive overview of physical functioning tests in patients with low back pain (LBP) and to investigate their reliability. A systematic computerized search was finalized in four different databases on June 24, 2017: PubMed, Web of Science, Embase, and MEDLINE. Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed during all stages of this review. Clinical studies that investigate the reliability of physical functioning tests in patients with LBP were eligible. The methodological quality of the included studies was assessed with the use of the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) checklist. To come to final conclusions on the reliability of the identified clinical tests, the current review assessed three factors, namely, outcome assessment, methodological quality, and consistency of description. A total of 20 studies were found eligible and 38 clinical tests were identified. Good overall test-retest reliability was concluded for the extensor endurance test (intraclass correlation coefficient [ICC]=0.93-0.97), the flexor endurance test (ICC=0.90-0.97), the 5-minute walking test (ICC=0.89-0.99), the 50-ft walking test (ICC=0.76-0.96), the shuttle walk test (ICC=0.92-0.99), the sit-to-stand test (ICC=0.91-0.99), and the loaded forward reach test (ICC=0.74-0.98). For inter-rater reliability, only one test, namely, the Biering-Sörensen test (ICC=0.88-0.99), could be concluded to have an overall good inter-rater reliability. None of the identified clinical tests could be concluded to have a good intrarater reliability. Further investigation should focus on a better overall study methodology and the use of identical protocols for the description of clinical tests. The assessment of reliability is only a first step in the recommendation process for the use of clinical tests. In future research, the identified clinical tests in the

  13. Vabrasio is a reliable test to rule out endometrial cancer

    DEFF Research Database (Denmark)

    Andersen, Anita; Lauszus, Finn Friis

    2015-01-01

    Introduction: Endometrial cancer is the most common gynaecological cancer in Denmark, and its incidence peaks in the postmenopausal years. The aim of the present study was to evaluate the effectiveness of vacuum aspirator (vabrasio) for the detection of endometrial cancer in terms of sensitivity......, specificity and predictive value. Methods: A cohort counting 503 women who had vabrasio was evaluated retrospectively. The women included were consecutive patients who had received vabrasio at the 
Department of Gynaecology and Obstetrics at Herning Hos­pital, Denmark, during a two-year period. They were iden......­tified by searching the hospital database for the Inter­na­tional Classification of Diseases, tenth version (ICD-10) code for vabrasio.
 Results: The indications for vabrasio were postmeno­pausal bleeding (45%), meno/metrorrhagia (43%) and thickened endometrium/polyp (6%). The first evaluation by vabrasio was normal...

  14. Reliability of fitness tests using methods and time periods common in sport and occupational management.

    Science.gov (United States)

    Burnstein, Bryan D; Steele, Russell J; Shrier, Ian

    2011-01-01

    Fitness testing is used frequently in many areas of physical activity, but the reliability of these measurements under real-world, practical conditions is unknown. To evaluate the reliability of specific fitness tests using the methods and time periods used in the context of real-world sport and occupational management. Cohort study. Eighteen different Cirque du Soleil shows. Cirque du Soleil physical performers who completed 4 consecutive tests (6-month intervals) and were free of injury or illness at each session (n = 238 of 701 physical performers). Performers completed 6 fitness tests on each assessment date: dynamic balance, Harvard step test, handgrip, vertical jump, pull-ups, and 60-second jump test. We calculated the intraclass coefficient (ICC) and limits of agreement between baseline and each time point and the ICC over all 4 time points combined. Reliability was acceptable (ICC > 0.6) over an 18-month time period for all pairwise comparisons and all time points together for the handgrip, vertical jump, and pull-up assessments. The Harvard step test and 60-second jump test had poor reliability (ICC < 0.6) between baseline and other time points. When we excluded the baseline data and calculated the ICC for 6-month, 12-month, and 18-month time points, both the Harvard step test and 60-second jump test demonstrated acceptable reliability. Dynamic balance was unreliable in all contexts. Limit-of-agreement analysis demonstrated considerable intraindividual variability for some tests and a learning effect by administrators on others. Five of the 6 tests in this battery had acceptable reliability over an 18-month time frame, but the values for certain individuals may vary considerably from time to time for some tests. Specific tests may require a learning period for administrators.

  15. The Reliability of Quality of Upper Extremity Skills Test in Children with Cerebral Palsy

    Directory of Open Access Journals (Sweden)

    Nazila Akbar-Fahimi

    2012-01-01

    Full Text Available Objective: The aim of this study was to survey the reliability of Intra-rater and Inter-rater with and without video camera assessment in children with spastic cerebral palsy. Materials & Methods: In this cross-sectional study, we validate the Quality of Upper Extremity Skill Test questionnaire. Fifty children with hemiplegia aged 19 to 95 months (mean age 61.31 ± 25.7 month were enrolled in our study using non random available approach. After obtaining parents’ consent, intra-rater assessment was performed in one session and intera rater assessment with camera after 10 days. Then, the third examiner did the reassessment using film observation of 46 children from 50. Spearman correlation for survey the reliability of intra-rater & inter rater with & without video recording assessment & gross motor function classification system 66 for determined functionality of child were used. Results: Intra-rater correlation was 0.774-0.996, Inter-rater correlation was 0.663-0.998 and correlation for video camera assessment was 0.710-0.974 for the first and third evaluation and 0.652-0.938 for second and third evaluation. P value for sub scales and total score was P<0.01. Conclusion: There is a high correlation in Intra rater and inter rater assessment with and without video recording in Quality of Upper Extremity Skill Test in children with cerebral palsy. So that it can be used as a reliable test to evaluate Quality of Upper Extremity Skills in these children.

  16. Strength cues and blocking at test promote reliable within-list criterion shifts in recognition memory.

    Science.gov (United States)

    Hicks, Jason L; Starns, Jeffrey J

    2014-07-01

    In seven experiments, we explored the potential for strength-based, within-list criterion shifts in recognition memory. People studied a mix of target words, some presented four times (strong) and others studied once (weak). In Experiments 1, 2, 4A, and 4B, the test was organized into alternating blocks of 10, 20, or 40 trials. Each block contained lures intermixed with strong targets only or weak targets only. In strength-cued conditions, test probes appeared in a unique font color for strong and weak blocks. In the uncued conditions of Experiments 1 and 2, similar strength blocks were tested, but strength was not cued with font color. False alarms to lures were lower in blocks containing strong target words, as compared with lures in blocks containing weak targets, but only when strength was cued with font color. Providing test feedback in Experiment 2 did not alter these results. In Experiments 3A-3C, test items were presented in a random order (i.e., not blocked by strength). Of these three experiments, only one demonstrated a significant shift even though strength cues were provided. Overall, the criterion shift was larger and more reliable as block size increased, and the shift occurred only when strength was cued with font color. These results clarify the factors that affect participants' willingness to change their response criterion within a test list.

  17. Using VIIRS Day/Night Band to Measure Electricity Supply Reliability: Preliminary Results from Maharashtra, India

    Directory of Open Access Journals (Sweden)

    Michael L. Mann

    2016-08-01

    Full Text Available Unreliable electricity supplies are common in developing countries and impose large socio-economic costs, yet precise information on electricity reliability is typically unavailable. This paper presents preliminary results from a machine-learning approach for using satellite imagery of nighttime lights to develop estimates of electricity reliability for western India at a finer spatial scale. We use data from the Visible Infrared Imaging Radiometer Suite (VIIRS onboard the Suomi National Polar Partnership (SNPP satellite together with newly-available data from networked household voltage meters. Our results point to the possibilities of this approach as well as areas for refinement. With currently available training data, we find a limited ability to detect individual outages identified by household-level measurements of electricity voltage. This is likely due to the relatively small number of individual outages observed in our preliminary data. However, we find that the approach can estimate electricity reliability rates for individual locations fairly well, with the predicted versus actual regression yielding an R2 > 0.5. We also find that, despite the after midnight overpass time of the SNPP satellite, the reliability estimates derived are representative of daytime reliability.

  18. A RELIABILITY TEST USED FOR THE DEVELOPMENT OF A LOYALTY SCALE

    Directory of Open Access Journals (Sweden)

    Florin-Alexandru LUCA

    2017-06-01

    Full Text Available The development of a loyalty model involves the construction of a proper research instrument. For the loyalty model of the clients for financial services, the pre-testing of the research questionnaire represents a significant stage. This article presents the methodology used in this stage for testing the reliability of a loyalty scale. Firstly, this implies choosing the appropriate scales for each variable included in the suggested research model. Secondly, the internal consistency for each of these scales is measured as an indicator of their reliability. The reliability analysis described represents an essential stage in building a measurement instrument for a loyalty model.

  19. Development of a test rig and its application for validation and reliability testing of safety-critical software

    Energy Technology Data Exchange (ETDEWEB)

    Thai, N D; McDonald, A M [Atomic Energy of Canada Ltd., Mississauga, ON (Canada)

    1996-12-31

    This paper describes a versatile test rig developed by AECL for functional testing of safety-critical software used in the process trip computers of the Wolsong CANDU stations. The description covers the hardware and software aspects of the test rig, the test language and its interpreter, and other major testing software utilities such as the test oracle, sampler and profiler. The paper also discusses the application of the rig in the final stages of testing of the process trip computer software, namely validation and reliability tests. It shows how random test cases are generated, test scripts prepared and automatically run on the test rig. The versatility of the rig is further demonstrated in other types of testing such as sub-system tests, verification of the test oracle, testing of newly-developed test script, self-test and calibration. (author). 5 tabs., 10 figs.

  20. Development of a test rig and its application for validation and reliability testing of safety-critical software

    International Nuclear Information System (INIS)

    Thai, N.D.; McDonald, A.M.

    1995-01-01

    This paper describes a versatile test rig developed by AECL for functional testing of safety-critical software used in the process trip computers of the Wolsong CANDU stations. The description covers the hardware and software aspects of the test rig, the test language and its interpreter, and other major testing software utilities such as the test oracle, sampler and profiler. The paper also discusses the application of the rig in the final stages of testing of the process trip computer software, namely validation and reliability tests. It shows how random test cases are generated, test scripts prepared and automatically run on the test rig. The versatility of the rig is further demonstrated in other types of testing such as sub-system tests, verification of the test oracle, testing of newly-developed test script, self-test and calibration. (author). 5 tabs., 10 figs

  1. Laboratory results of the AOF system testing

    Science.gov (United States)

    Kolb, Johann; Madec, Pierre-Yves; Arsenault, Robin; Oberti, Sylvain; Paufique, Jérôme; La Penna, Paolo; Ströbele, Stefan; Donaldson, Robert; Soenke, Christian; Suárez Valles, Marcos; Kiekebusch, Mario; Argomedo, Javier; Le Louarn, Miska; Vernet, Elise; Haguenauer, Pierre; Duhoux, Philippe; Aller-Carpentier, Emmanuel; Valenzuela, Jose Javier; Guerra, Juan Carlos

    2016-07-01

    For two years starting in February 2014, the AO modules GRAAL for HAWK-I and GALACSI for MUSE of the Adaptive Optics Facility project have undergone System Testing at ESO's Headquarters. They offer four different modes: NGS SCAO, LGS GLAO in the IR, LGS GLAO and LTAO in the visible. A detailed characterization of those modes was made possible by the existence of ASSIST, a test bench emulating an adaptive VLT including the Deformable Secondary Mirror, a star simulator and turbulence generator and a VLT focal plane re-imager. This phase aimed at validating all the possible components and loops of the AO modules before installation at the actual VLT that comprises the added complexity of real LGSs, a harsher non-reproducible environment and the adaptive telescope control. In this paper we present some of the major results obtained and challenges encountered during the phase of System Tests, like the preparation of the Acquisition sequence, the testing of the Jitter loop, the performance optimization in GLAO and the offload of low-order modes from the DSM to the telescope (restricted to the M2 hexapod). The System Tests concluded with the successful acceptance, shipping, installation and first commissioning of GRAAL in 2015 as well as the acceptance and shipping of GALACSI, ready for installation and commissioning early 2017.

  2. Testing comparison models of DASS-12 and its reliability among adolescents in Malaysia.

    Science.gov (United States)

    Osman, Zubaidah Jamil; Mukhtar, Firdaus; Hashim, Hairul Anuar; Abdul Latiff, Latiffah; Mohd Sidik, Sherina; Awang, Hamidin; Ibrahim, Normala; Abdul Rahman, Hejar; Ismail, Siti Irma Fadhilah; Ibrahim, Faisal; Tajik, Esra; Othman, Norlijah

    2014-10-01

    The 21-item Depression, Anxiety and Stress Scale (DASS-21) is frequently used in non-clinical research to measure mental health factors among adults. However, previous studies have concluded that the 21 items are not stable for utilization among the adolescent population. Thus, the aims of this study are to examine the structure of the factors and to report on the reliability of the refined version of the DASS that consists of 12 items. A total of 2850 students (aged 13 to 17 years old) from three major ethnic in Malaysia completed the DASS-21. The study was conducted at 10 randomly selected secondary schools in the northern state of Peninsular Malaysia. The study population comprised secondary school students (Forms 1, 2 and 4) from the selected schools. Based on the results of the EFA stage, 12 items were included in a final CFA to test the fit of the model. Using maximum likelihood procedures to estimate the model, the selected fit indices indicated a close model fit (χ(2)=132.94, df=57, p=.000; CFI=.96; RMR=.02; RMSEA=.04). Moreover, significant loadings of all the unstandardized regression weights implied an acceptable convergent validity. Besides the convergent validity of the item, a discriminant validity of the subscales was also evident from the moderate latent factor inter-correlations, which ranged from .62 to .75. The subscale reliability was further estimated using Cronbach's alpha and the adequate reliability of the subscales was obtained (Total=76; Depression=.68; Anxiety=.53; Stress=.52). The new version of the 12-item DASS for adolescents in Malaysia (DASS-12) is reliable and has a stable factor structure, and thus it is a useful instrument for distinguishing between depression, anxiety and stress. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Pre-analytical and analytical aspects affecting clinical reliability of plasma glucose results.

    Science.gov (United States)

    Pasqualetti, Sara; Braga, Federica; Panteghini, Mauro

    2017-07-01

    The measurement of plasma glucose (PG) plays a central role in recognizing disturbances in carbohydrate metabolism, with established decision limits that are globally accepted. This requires that PG results are reliable and unequivocally valid no matter where they are obtained. To control the pre-analytical variability of PG and prevent in vitro glycolysis, the use of citrate as rapidly effective glycolysis inhibitor has been proposed. However, the commercial availability of several tubes with studies showing different performance has created confusion among users. Moreover, and more importantly, studies have shown that tubes promptly inhibiting glycolysis give PG results that are significantly higher than tubes containing sodium fluoride only, used in the majority of studies generating the current PG cut-points, with a different clinical classification of subjects. From the analytical point of view, to be equivalent among different measuring systems, PG results should be traceable to a recognized higher-order reference via the implementation of an unbroken metrological hierarchy. In doing this, it is important that manufacturers of measuring systems consider the uncertainty accumulated through the different steps of the selected traceability chain. In particular, PG results should fulfil analytical performance specifications defined to fit the intended clinical application. Since PG has tight homeostatic control, its biological variability may be used to define these limits. Alternatively, given the central diagnostic role of the analyte, an outcome model showing the impact of analytical performance of test on clinical classifications of subjects can be used. Using these specifications, performance assessment studies employing commutable control materials with values assigned by reference procedure have shown that the quality of PG measurements is often far from desirable and that problems are exacerbated using point-of-care devices. Copyright © 2017 The Canadian

  4. Experiences in Germany with reliability data assessment, results and current problems

    International Nuclear Information System (INIS)

    Homke, P.; Kutsch, W.; Lindauer, E.

    1982-01-01

    This paper gives a survey on reliability data assessment in the FRG. The activities, which were carried out for the German Risk Assessment Study are presented together with selected results. A systematic data collection in a nuclear power plant is described and the experiences are discussed, which were gained in this project

  5. An accelerated stress testing program for determining the reliability sensitivity of silicon solar cells to encapsulation and metallization systems

    Science.gov (United States)

    Lathrop, J. W.; Davis, C. W.; Royal, E.

    1982-01-01

    The use of accelerated testing methods in a program to determine the reliability attributes of terrestrial silicon solar cells is discussed. Different failure modes are to be expected when cells with and without encapsulation are subjected to accelerated testing and separate test schedules for each are described. Unencapsulated test cells having slight variations in metallization are used to illustrate how accelerated testing can highlight different diffusion related failure mechanisms. The usefulness of accelerated testing when applied to encapsulated cells is illustrated by results showing that moisture related degradation may be many times worse with some forms of encapsulation than with no encapsulation at all.

  6. Reliability Engineering

    International Nuclear Information System (INIS)

    Lee, Sang Yong

    1992-07-01

    This book is about reliability engineering, which describes definition and importance of reliability, development of reliability engineering, failure rate and failure probability density function about types of it, CFR and index distribution, IFR and normal distribution and Weibull distribution, maintainability and movability, reliability test and reliability assumption in index distribution type, normal distribution type and Weibull distribution type, reliability sampling test, reliability of system, design of reliability and functionality failure analysis by FTA.

  7. Results from the CLIC Test Facility

    CERN Document Server

    Braun, H; Bossart, Rudolf; Chautard, F; Corsini, R; Delahaye, J P; Godot, J C; Hutchins, S; Kamber, I; Madsen, J H B; Rinolfi, Louis; Rossat, G; Schreiber, S; Suberlucq, Guy; Thorndahl, L; Wilson, Ian H; Wuensch, Walter

    1996-01-01

    In order to study the principle of the Compact Linear Collider (CLIC) based on the Two Beam Acceleration (TBA) scheme at high frequency, a CLIC Test Facility (CTF) has been set-up at CERN. After four years of successful running, the experimental programme is now fully completed and all its objectives reached, particularly the generation of a high intensity drive beam with short bunches by a photo-injector, the production of 30 GHz RF power and the acceleration of a probe beam by 30 GHz structures. A summary of the CTF results and their impact on linear collider design is given. This covers 30 GHz high power testing, study of intense, short single bunches; as well as RF-Gun, photocathode and beam diagnostic developments. A second phase of the test facility (CTF2) is presently being installed to demonstrate the feasibility of the TBA scheme by constructing a fully engineered, 10 m long, test section very similar to the CLIC drive and main linacs, producing up to 480 MW of peak RF power at 30 GHz and acceleratin...

  8. Long term test-retest reliability of Oswestry Disability Index in male office workers.

    Science.gov (United States)

    Irmak, Rafet; Baltaci, Gul; Ergun, Nevin

    2015-01-01

    The Oswestry Disability Index (ODI) is one of the most common condition specific outcome measures used in the management of spinal disorders. But there is insufficient study on healthy populations and long term test-retest reliability. This is important because healthy populations are often used for control groups in low back pain interventions, and knowing the reliability of the controls affects the interpretation of the findings of these studies. The purpose of this study is to determine the long term test-retest reliability of ODI in office workers. Participants who have no chronic low back pain history were included in study. Subjects were assessed by the Turkish-ODI 2.0 (e-forms) on 1st, 2nd, 4th, 8th, 15th, 30th days to determine the stability of ODI scores over time. The study began with 58 (12 female, 46 male) participants. 36 (3 female, 33 male) participated for the full 30 days. Kolmogorov-Smirnov and Friedman tests were used. Test-retest reliability was evaluated by using nonparametric statistics. All tests were done by using SPSS-11. There was no statistically significant difference among the median scores of each day. (χ= 6.482, p >  0.05). The difference between median score of the days with 1st day was neither statistically nor clinically significant. ODI has long term test re-test reliability in healthy subjects over a 1 month time interval.

  9. Solar energy characteristics and some photovoltaic testing results in Jeddah

    Energy Technology Data Exchange (ETDEWEB)

    Mosalam Shaltout, M A

    1986-01-01

    The data for global radiation were analysed to investigate the correlation with climatological factors. Solar cell module testing under Jeddah climatic conditions was initiated in 1984-1985. The goal of this work was to study the performance and reliability of a commercially-available module in outdoor conditions in order to obtain information on solar cell system design, and to observe the influence of our specific climate conditions on module energy output. The use of results obtained for precise system sizing is discussed.

  10. Test results of the UNK superconducting dipole magnets

    International Nuclear Information System (INIS)

    Ageev, A.I.; Andreev, N.I.; Gridasov, V.I.

    1993-01-01

    Results of studied, training, temperature and velocity dependence of 25 critical current of superconducting magnets (SC), as well as, of dynamic losses of dipole and statical inflows in UNK operating cycle at currents that are higher than critical ones (5250 A), are presented. Service life tests of SC-dipole demonstrated that their design may ensure durable operation of magnets under UNK conditions. Conclusions are made that temperature margin of magnets equal to 0.8 K will enable to ensure their reliable operation under dynamic and radiation heat releases at acceleration and extraction of beam, as well as, under emergency extraction of stored energy. 4 refs.; 5 figs

  11. Design, construction and testing of replacement nuclear coolant pump stators to meet today's equipment reliability expectations

    International Nuclear Information System (INIS)

    Fostier, L.; Howell, D.

    2005-01-01

    The reliability expectations of equipment and components in today's nuclear power plant are much greater than three or more decades ago when nuclear plants were first constructed due to economic impact of a failure. Very few components in a pressurized water reactor plant can have as much impact of the plants capacity factor as a catastrophic failure of a reactor coolant pump winding. This paper describes the maintenance approach taken by one North American utility in attempt to preclude such failures. The paper will discuss the challenges of the reactor coolant pump application and the enhancements made in the winding design and construction by the supplier to address failure mechanisms so as to better meet present reliability expectations in accordance with dedicated specifications. The paper will also present the in-process and final testing requirements and limits imposed in an attempt to ensure quality of the machine windings, along with selected test results from the stators that have been designed and constructed to these specifications to date. (author)

  12. A Systematic Review of Statistical Methods Used to Test for Reliability of Medical Instruments Measuring Continuous Variables

    Directory of Open Access Journals (Sweden)

    Rafdzah Zaki

    2013-06-01

    Full Text Available   Objective(s: Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice.   Materials and Methods: In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. Results: The Intra-class Correlation Coefficient (ICC is the most popular method with 25 (60% studies having used this method followed by the comparing means (8 or 19%. Out of 25 studies using the ICC, only 7 (28% reported the confidence intervals and types of ICC used. Most studies (71% also tested the agreement of instruments. Conclusion: This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  13. The Benchmark Test Results of QNX RTOS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jang Yeol; Lee, Young Jun; Cheon, Se Woo; Lee, Jang Soo; Kwon, Kee Choon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    A Real-Time Operating System(RTOS) is an Operating System(OS) intended for real-time applications. Benchmarking is a point of reference by which something can be measured. The QNX is a Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available Personal Computer(PC) for applications such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS). The ELMSYS PC Hardware is being qualified by KTL(Korea Testing Lab.) for use as a Cabinet Operator Module(COM). The QNX RTOS is being dedicated by Korea Atomic Energy Research Institute (KAERI). This paper describes the outline and benchmarking test results on Context Switching, Message Passing, Synchronization and Deadline Violation of QNX RTOS under the ELMSYS PC platform

  14. The Benchmark Test Results of QNX RTOS

    International Nuclear Information System (INIS)

    Kim, Jang Yeol; Lee, Young Jun; Cheon, Se Woo; Lee, Jang Soo; Kwon, Kee Choon

    2010-01-01

    A Real-Time Operating System(RTOS) is an Operating System(OS) intended for real-time applications. Benchmarking is a point of reference by which something can be measured. The QNX is a Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available Personal Computer(PC) for applications such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS). The ELMSYS PC Hardware is being qualified by KTL(Korea Testing Lab.) for use as a Cabinet Operator Module(COM). The QNX RTOS is being dedicated by Korea Atomic Energy Research Institute (KAERI). This paper describes the outline and benchmarking test results on Context Switching, Message Passing, Synchronization and Deadline Violation of QNX RTOS under the ELMSYS PC platform

  15. Synthesis of low cycle fatigue test results

    International Nuclear Information System (INIS)

    Andrews, R.M.

    1990-01-01

    Axial strain controlled cycle fatigue tests were carried out on type 316 stainless steel parent metal, vacuum and non-vacuum electron beams welds, submerged arc welds and gas shielded metal arc welds. Testing covered total strains in the range 0.6% to 2%, and was at room temperature and 550 0 C. Parent metal and the electron beam welds showed rapid cyclic hardening, while arc welds showed little hardening. The weld metal cyclic stress-strain response was above that obtained for the parent metal, although below data obtained by other workers for similar parent materials. Weld metal endurances were above the ASME N47 continuous cycling design line at both temperatures, and comparable with parent metal data. However, the weld metal data approached the design line at low strain ranges (around 0.5%). Endurances were predicted from crack growth rates estimated from striation spacings, giving acceptable results except for the gas shielded metal arc weldments. (author)

  16. Results from the STAR TPC system test

    International Nuclear Information System (INIS)

    Betts, W.

    1996-01-01

    A system test of various components of the Solenoidal Tracker at RHIC (STAR) detector, operating in concern, has recently come on-line. Communication between a major sub-detector, a sector of the Time Projection Chamber (TPC), and the trigger, data acquisition and slow controls systems has been established, enabling data from cosmic ray muons to be collected. First results from an analysis of the TPC data are presented. These include measurements of system noise, electronic parameters such as amplifier gains and pedestal values, and tracking resolution for cosmic ray muons and laser induced ionization tracks. A discussion on the experience gained in integrating the different components for the system test is also given

  17. Test-retest reliability of the eating disorder examination-questionnaire (EDE-Q) in a college sample

    OpenAIRE

    Rose, Jennifer S; Vaewsorn, Adin; Rosselli-Navarra, Francine; Wilson, G Terence; Weissman, Ruth Striegel

    2013-01-01

    Background The Eating Disorder Examination-Questionnaire (EDE-Q), a widely used self-report instrument, is often used for measuring change in eating disorder symptoms over the course of treatment. However, limited data exist about test-retest reliability, particularly for men. The current study evaluated EDE-Q 7-day test-retest reliability in male (n = 47) and female (n = 44) undergraduate students together and separately by gender. Results Internal consistency was consistently higher for wom...

  18. Reliability of different methods used for forming of working samples in the laboratory for seed testing

    Directory of Open Access Journals (Sweden)

    Opra Branislava

    2000-01-01

    Full Text Available The testing of seed quality starts from the moment a sample is formed in a warehouse during processing or packaging of the seed. The seed sampling as the process of obtaining the working sample also assumes each step undertaken during its testing in the laboratory. With the aim of appropriate forming of a seed sample in the laboratory, the usage of seed divider is prescribed for large seeded species (such as seed the size of wheat or larger (ISTA Rules, 1999. The aim of this paper was the comparison of different methods used for obtaining the working samples of maize and wheat seeds using conical, soil and centrifugal dividers. The number of seed of added admixtures confirmed the reliability of working samples formation. To each maize sample (1000 g 10 seeds of the following admixtures were added: Zea mays L. (red pericarp, Hordeum vulgäre L., Triticum aestivum L., and Glycine max (L. Merr. Two methods were used for formation of maze seed working sample. To wheat samples (1000 g 10 seeds of each of the following species were added: Avena saliva (hulled seeds, Hordeum vulgäre L., Galium tricorne Stokes, and Polygonum lapatifolmm L. For formation of wheat seed working samples four methods were used. Optimum of 9, but not less than 7 seeds of admixture were due to be determined in the maize seed working sample, while for wheat, at least one seed of admixture was expected to be found in the working sample. The obtained results confirmed that the formation of the maize seed working samples was the most reliable when centrifugal divider, the first method was used (average of admixture - 9.37. From the observed admixtures the seed of Triticum aestivum L. was the most uniformly distributed, the first method also being used (6.93. The second method gains high average values satisfying the given criterion, but it should be used with previous homogenization of the sample being tested. The forming of wheat seed working samples is the most reliable if the

  19. Bayes Analysis and Reliability Implications of Stress-Rupture Testing a Kevlar/Epoxy COPV Using Temperature and Pressure Acceleration

    Science.gov (United States)

    Phoenix, S. Leigh; Kezirian, Michael T.; Murthy, Pappu L. N.

    2009-01-01

    Composite Overwrapped Pressure Vessels (COPVs) that have survived a long service time under pressure generally must be recertified before service is extended. Flight certification is dependent on the reliability analysis to quantify the risk of stress rupture failure in existing flight vessels. Full certification of this reliability model would require a statistically significant number of lifetime tests to be performed and is impractical given the cost and limited flight hardware for certification testing purposes. One approach to confirm the reliability model is to perform a stress rupture test on a flight COPV. Currently, testing of such a Kevlar49 (Dupont)/epoxy COPV is nearing completion. The present paper focuses on a Bayesian statistical approach to analyze the possible failure time results of this test and to assess the implications in choosing between possible model parameter values that in the past have had significant uncertainty. The key uncertain parameters in this case are the actual fiber stress ratio at operating pressure, and the Weibull shape parameter for lifetime; the former has been uncertain due to ambiguities in interpreting the original and a duplicate burst test. The latter has been uncertain due to major differences between COPVs in the database and the actual COPVs in service. Any information obtained that clarifies and eliminates uncertainty in these parameters will have a major effect on the predicted reliability of the service COPVs going forward. The key result is that the longer the vessel survives, the more likely the more optimistic stress ratio model is correct. At the time of writing, the resulting effect on predicted future reliability is dramatic, increasing it by about one "nine," that is, reducing the predicted probability of failure by an order of magnitude. However, testing one vessel does not change the uncertainty on the Weibull shape parameter for lifetime since testing several vessels would be necessary.

  20. Validity and Reliability Study of the Korean Tinetti Mobility Test for Parkinson's Disease.

    Science.gov (United States)

    Park, Jinse; Koh, Seong-Beom; Kim, Hee Jin; Oh, Eungseok; Kim, Joong-Seok; Yun, Ji Young; Kwon, Do-Young; Kim, Younsoo; Kim, Ji Seon; Kwon, Kyum-Yil; Park, Jeong-Ho; Youn, Jinyoung; Jang, Wooyoung

    2018-01-01

    Postural instability and gait disturbance are the cardinal symptoms associated with falling among patients with Parkinson's disease (PD). The Tinetti mobility test (TMT) is a well-established measurement tool used to predict falls among elderly people. However, the TMT has not been established or widely used among PD patients in Korea. The purpose of this study was to evaluate the reliability and validity of the Korean version of the TMT for PD patients. Twenty-four patients diagnosed with PD were enrolled in this study. For the interrater reliability test, thirteen clinicians scored the TMT after watching a video clip. We also used the test-retest method to determine intrarater reliability. For concurrent validation, the unified Parkinson's disease rating scale, Hoehn and Yahr staging, Berg Balance Scale, Timed-Up and Go test, 10-m walk test, and gait analysis by three-dimensional motion capture were also used. We analyzed receiver operating characteristic curve to predict falling. The interrater reliability and intrarater reliability of the Korean Tinetti balance scale were 0.97 and 0.98, respectively. The interrater reliability and intra-rater reliability of the Korean Tinetti gait scale were 0.94 and 0.96, respectively. The Korean TMT scores were significantly correlated with the other clinical scales and three-dimensional motion capture. The cutoff values for predicting falling were 14 points (balance subscale) and 10 points (gait subscale). We found that the Korean version of the TMT showed excellent validity and reliability for gait and balance and had high sensitivity and specificity for predicting falls among patients with PD.

  1. Strength and Pain Threshold Handheld Dynamometry Test Reliability in Patellofemoral Pain.

    Science.gov (United States)

    van der Heijden, R A; Vollebregt, T; Bierma-Zeinstra, S M A; van Middelkoop, M

    2015-12-01

    Patellofemoral pain syndrome (PFPS), characterized by peri- and retropatellar pain, is a common disorder in young, active people. The etiology is unclear; however, quadriceps strength seems to be a contributing factor, and sensitization might play a role. The study purpose is determining the inter-rater reliability of handheld dynamometry to test both quadriceps strength and pressure pain threshold (PPT), a measure for sensitization, in patients with PFPS. This cross-sectional case-control study comprises 3 quadriceps strength and one PPT measurements performed by 2 independent investigators in 22 PFPS patients and 16 matched controls. Inter-rater reliability was analyzed using intraclass correlation coefficients (ICC) and Bland-Altman plots. Inter-rater reliability of quadriceps strength testing was fair to good in PFPS patients (ICC=0.72) and controls (ICC=0.63). Bland-Altman plots showed an increased difference between assessors when average quadriceps strength values exceeded 250 N. Inter-rater reliability of PPT was excellent in patients (ICC=0.79) and fair to good in controls (ICC=0.52). Handheld dynamometry seems to be a reliable method to test both quadriceps strength and PPT in PFPS patients. Inter-rater reliability was higher in PFPS patients compared to control subjects. With regard to quadriceps testing, a higher variance between assessors occurs when quadriceps strength increases. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Investigation of reliability, validity and normality Persian version of the California Critical Thinking Skills Test; Form B (CCTST

    Directory of Open Access Journals (Sweden)

    Khallli H

    2003-04-01

    Full Text Available Background: To evaluate the effectiveness of the present educational programs in terms of students' achieving problem solving, decision making and critical thinking skills, reliable, valid and standard instrument are needed. Purposes: To Investigate the Reliability, validity and Norm of CCTST Form.B .The California Critical Thinking Skills Test contain 34 multi-choice questions with a correct answer in the jive Critical Thinking (CT cognitive skills domain. Methods: The translated CCTST Form.B were given t0405 BSN nursing students ojNursing Faculties located in Tehran (Tehran, Iran and Shahid Beheshti Universitiesthat were selected in the through random sampling. In order to determine the face and content validity the test was translated and edited by Persian and English language professor and researchers. it was also confirmed by judgments of a panel of medical education experts and psychology professor's. CCTST reliability was determined with internal consistency and use of KR-20. The construct validity of the test was investigated with factor analysis and internal consistency and group difference. Results: The test coefficien for reliablity was 0.62. Factor Analysis indicated that CCTST has been formed from 5 factor (element namely: Analysis, Evaluation, lriference, Inductive and Deductive Reasoning. Internal consistency method shows that All subscales have been high and positive correlation with total test score. Group difference method between nursing and philosophy students (n=50 indicated that there is meaningfUl difference between nursing and philosophy students scores (t=-4.95,p=0.OOO1. Scores percentile norm also show that percentile offifty scores related to 11 raw score and 95, 5 percentiles are related to 17 and 6 raw score ordinary. Conclusions: The Results revealed that the questions test is sufficiently reliable as a research tool, and all subscales measure a single construct (Critical Thinking and are able to distinguished the

  3. Evaluation of ring tensile test results

    International Nuclear Information System (INIS)

    Chatterjee, S.; Anantharaman, S.; Balakrishnan, K.S.; Sivaramakrish, K.S.

    1990-01-01

    Ring specimens of 5-mm width cut from Zircaloy-2 cladding of reactor operated fuel elements that had experienced 5000 to 15,000 MWD/T of fuel burnup were subjected to ring tensile testing. The true stress-true strain data points up to the onset of necking from the individual load-elongation curves of these specimens were used as input data in Voce's equation. The results reveal that the uniform elongation (UE) values generated using Voce's equation were within (UE-2)% of the experimental percent uniform elongation (UE%). The corresponding ultimate tensile strength values were within ±1%. The uncertainty inherently associated in the determination of gauge length introduces extraneous deformation in the rings tested. Previous results had shown that a 14% increase in cladding diameter caused the gauge length to increase by 40%. To simulate the contribution of extraneous deformation due to an increase in cladding diameter, an analysis of the variation of the tensile parameters (uniform elongation and ultimate tensile strength) due to increase in the gauge length in the range of 10 to 40% was carried out. The results are discussed

  4. Test of Understanding of Vectors: A Reliable Multiple-Choice Vector Concept Test

    Science.gov (United States)

    Barniol, Pablo; Zavala, Genaro

    2014-01-01

    In this article we discuss the findings of our research on students' understanding of vector concepts in problems without physical context. First, we develop a complete taxonomy of the most frequent errors made by university students when learning vector concepts. This study is based on the results of several test administrations of open-ended…

  5. Dual color radiometer imagery and test results

    International Nuclear Information System (INIS)

    Silver, A.; Carlen, F.; Link, D.; Zegel, F.

    1989-01-01

    This paper presents a review of the technical characteristics of the Dual Color Radiometer and recent data and test results. The Dual Color Radiometer is a state-of-the-art device that provides simultaneous pixel to pixel registered thermal imagery in both the 3 to 5 and 8 to 12 micron regions. The device is unique in terms of its spatial and temperature resolution of less than 0.10 degrees C temperature and 0.10 milliradian spatial resolution. In addition, the device is tailored for use by the Automatic Target Recognizer (ATR) community

  6. A flexible latent class approach to estimating test-score reliability

    NARCIS (Netherlands)

    van der Palm, D.W.; van der Ark, L.A.; Sijtsma, K.

    2014-01-01

    The latent class reliability coefficient (LCRC) is improved by using the divisive latent class model instead of the unrestricted latent class model. This results in the divisive latent class reliability coefficient (DLCRC), which unlike LCRC avoids making subjective decisions about the best solution

  7. Arc melter demonstration baseline test results

    International Nuclear Information System (INIS)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; Oden, L.L.; O'Connor, W.K.; Turner, P.C.

    1994-07-01

    This report describes the test results and evaluation for the Phase 1 (baseline) arc melter vitrification test series conducted for the Buried Waste Integrated Demonstration program (BWID). Phase 1 tests were conducted on surrogate mixtures of as-incinerated wastes and soil. Some buried wastes, soils, and stored wastes at the INEL and other DOE sites, are contaminated with transuranic (TRU) radionuclides and hazardous organics and metals. The high temperature environment in an electric arc furnace may be used to process these wastes to produce materials suitable for final disposal. An electric arc furnace system can treat heterogeneous wastes and contaminated soils by (a) dissolving and retaining TRU elements and selected toxic metals as oxides in the slag phase, (b) destroying organic materials by dissociation, pyrolyzation, and combustion, and (c) capturing separated volatilized metals in the offgas system for further treatment. Structural metals in the waste may be melted and tapped separately for recycle or disposal, or these metals may be oxidized and dissolved into the slag. The molten slag, after cooling, will provide a glass/ceramic final waste form that is homogeneous, highly nonleachable, and extremely durable. These features make this waste form suitable for immobilization of TRU radionuclides and toxic metals for geologic timeframes. Further, the volume of contaminated wastes and soils will be substantially reduced in the process

  8. AOF: standalone test results of GALACSI

    Science.gov (United States)

    La Penna, P.; Aller Carpentier, E.; Argomedo, J.; Arsenault, R.; Conzelmann, R. D.; Delabre, B.; Donaldson, R.; Gago, F.; Gutierrez-Cheetam, P.; Hubin, N.; Jolley, P.; Kiekebusch, M.; Kirchbauer, J. P.; Klein, B.; Kolb, J.; Kuntschner, H.; Le Louarn, M.; Lizon, J.-L.; Madec, P.-Y.; Manescau, A.; Mehrgan, L.; Oberti, S.; Quentin, J.; Sedghi, B.; Ströbele, S.; Suárez Valles, M.; Soenke, C.; Tordo, S.; Vernet, J.

    2016-07-01

    GALACSI is the Adaptive Optics (AO) module that will serve the MUSE Integral Field Spectrograph. In Wide Field Mode it will enhance the collected energy in a 0.2"×0.2" pixel by a factor 2 at 750 nm over a Field of View (FoV) of 1'×1' using the Ground Layer AO (GLAO) technique. In Narrow Field Mode, it will provide a Strehl Ratio of 5% (goal 10%) at 650 nm, but in a smaller FoV (7.5"×7.5" FoV), using Laser Tomography AO (LTAO). Before being ready for shipping to Paranal, the system has gone through an extensive testing phase in Europe, first in standalone mode and then in closed loop with the DSM in Europe. After outlining the technical features of the system, we describe here the first part of that testing phase and the integration with the AOF ASSIST (Adaptive Secondary Setup and Instrument Stimulator) testbench, including a specific adapter for the IRLOS truth sensor. The procedures for the standalone verification of the main system performances are outlined, and the results of the internal functional tests of GALACSI after full integration and alignment on ASSIST are presented.

  9. Partial-array test results in IFSMTF

    International Nuclear Information System (INIS)

    Lue, J.W.; Dresner, L.; Koizumi, K.; Lubell, M.S.; Luton, J.N.; Shen, S.S.; Zahn, G.R.; Zichy, J.A.

    1985-01-01

    Preliminary performance tests of two large superconducting magnets have been carried out in the International Fusion Superconducting Magnet Test Facility (IFSMTF). Each of the Japanese (JA) and General Dynamics/Convair (GD) coils was operated up to its full design current of 10.2 kA with the other serving as an adjacent background coil at 40% of design current. Cryostatic stability was demonstrated for both coils by noting recovery from a full half-turn (5 m) driven normal. A new pick-up coil compensation scheme was successfully used for the quench detection system. Each coil remained superconducting when the other was dumped. Unique instrumentation was used to measure changes in bore dimensions and displacement of the winding from the coil case. Agreement between structural analysis and measurement of bore dimension changes resulting from magnetic loads is good. The Swiss (CH) coil underwent only a cryogenic test. The forced cooling worked well and an inlet temperature of 3.8 K was demonstrated

  10. Test-retest reliability of barbell velocity during the free-weight bench-press exercise.

    Science.gov (United States)

    Stock, Matt S; Beck, Travis W; DeFreitas, Jason M; Dillon, Michael A

    2011-01-01

    The purpose of this study was to calculate test-retest reliability statistics for peak barbell velocity during the free-weight bench-press exercise for loads corresponding to 10-90% of the 1-repetition maximum (1RM). Twenty-one healthy, resistance-trained men (mean ± SD age = 23.5 ± 2.7 years; body mass = 90.5 ± 14.6 kg; 1RM bench press = 125.4 ± 18.4 kg) volunteered for this study. A minimum of 48 hours after a maximal strength testing and familiarization session, the subjects performed single repetitions of the free-weight bench-press exercise at each tenth percentile (10-90%) of the 1RM on 2 separate occasions. For each repetition, the subjects were instructed to press the barbell as rapidly as possible, and peak barbell velocity was measured with a Tendo Weightlifting Analyzer. The test-retest intraclass correlation coefficients (model 2,1) and corresponding standard errors of measurement (expressed as percentages of the mean barbell velocity values) were 0.717 (4.2%), 0.572 (5.0%), 0.805 (3.1%), 0.669 (4.7%), 0.790 (4.6%), 0.785 (4.8%), 0.811 (5.8%), 0.714 (10.3%), and 0.594 (12.6%) for the weights corresponding to 10-90% 1RM. There were no mean differences between the barbell velocity values from trials 1 and 2. These results indicated moderate to high test-retest reliability for barbell velocity from 10 to 70% 1RM but decreased consistency at 80 and 90% 1RM. When examining barbell velocity during the free-weight bench-press exercise, greater measurement error must be overcome at 80 and 90% 1RM to be confident that an observed change is meaningful.

  11. Interrater and Intrarater Reliability of the Balance Computerized Adaptive Test in Patients With Stroke.

    Science.gov (United States)

    Chiang, Hsin-Yu; Lu, Wen-Shian; Yu, Wan-Hui; Hsueh, I-Ping; Hsieh, Ching-Lin

    2018-04-11

    To examine the interrater and intrarater reliability of the Balance Computerized Adaptive Test (Balance CAT) in patients with chronic stroke having a wide range of balance functions. Repeated assessments design (1wk apart). Seven teaching hospitals. A pooled sample (N=102) including 2 independent groups of outpatients (n=50 for the interrater reliability study; n=52 for the intrarater reliability study) with chronic stroke. Not applicable. Balance CAT. For the interrater reliability study, the values of intraclass correlation coefficient, minimal detectable change (MDC), and percentage of MDC (MDC%) for the Balance CAT were .84, 1.90, and 31.0%, respectively. For the intrarater reliability study, the values of intraclass correlation coefficient, MDC, and MDC% ranged from .89 to .91, from 1.14 to 1.26, and from 17.1% to 18.6%, respectively. The Balance CAT showed sufficient intrarater reliability in patients with chronic stroke having balance functions ranging from sitting with support to independent walking. Although the Balance CAT may have good interrater reliability, we found substantial random measurement error between different raters. Accordingly, if the Balance CAT is used as an outcome measure in clinical or research settings, same raters are suggested over different time points to ensure reliable assessments. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  12. A limited assessment of the ASEP human reliability analysis procedure using simulator examination results

    International Nuclear Information System (INIS)

    Gore, B.R.; Dukelow, J.S. Jr.; Mitts, T.M.; Nicholson, W.L.

    1995-10-01

    This report presents a limited assessment of the conservatism of the Accident Sequence Evaluation Program (ASEP) human reliability analysis (HRA) procedure described in NUREG/CR-4772. In particular, the, ASEP post-accident, post-diagnosis, nominal HRA procedure is assessed within the context of an individual's performance of critical tasks on the simulator portion of requalification examinations administered to nuclear power plant operators. An assessment of the degree to which operator perforn:Lance during simulator examinations is an accurate reflection of operator performance during actual accident conditions was outside the scope of work for this project; therefore, no direct inference can be made from this report about such performance. The data for this study are derived from simulator examination reports from the NRC requalification examination cycle. A total of 4071 critical tasks were identified, of which 45 had been failed. The ASEP procedure was used to estimate human error probability (HEP) values for critical tasks, and the HEP results were compared with the failure rates observed in the examinations. The ASEP procedure was applied by PNL operator license examiners who supplemented the limited information in the examination reports with expert judgment based upon their extensive simulator examination experience. ASEP analyses were performed for a sample of 162 critical tasks selected randomly from the 4071, and the results were used to characterize the entire population. ASEP analyses were also performed for all of the 45 failed critical tasks. Two tests were performed to assess the bias of the ASEP HEPs compared with the data from the requalification examinations. The first compared the average of the ASEP HEP values with the fraction of the population actually failed and it found a statistically significant factor of two bias on the average

  13. Development, construct validity and test-retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball

    NARCIS (Netherlands)

    de Witte, Annemarie M. H.; Hoozemans, Marco J. M.; Berger, Monique A. M.; van der Slikke, Rienk M. A.; van der Woude, Lucas H. V.; Veeger, Dirkjan (H. E. J)

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of

  14. Improvement in reliability and accuracy of heater tube eddy current testing by integration with an appropriate destructive test

    International Nuclear Information System (INIS)

    Giovanelli, F.; Gabiccini, S.; Tarli, R.; Motta, P.

    1988-01-01

    A specially developed destructive test is described showing how the reliability and accuracy of a non-destructive technique can be improved if it is suitably accompanied by an appropriate destructive test. The experiment was carried out on samples of AISI 304L tubes from the low-pressure (LP) preheaters of a BWR 900 MW nuclear plant. (author)

  15. Test-retest reliability of the 20-sec Wingate test to assess anaerobic power in children with cerebral palsy

    NARCIS (Netherlands)

    Dallmeijer, A.J.; Scholtes, V.A.B.; Brehm, M.A.; Becher, J.G.

    2013-01-01

    OBJECTIVE: The aim of this study was to determine the test-retest reliability of the 20-sec Wingate anaerobic test in children with cerebral palsy. DESIGN: Participants were 22 ambulant children with cerebral palsy, with Gross Motor Function Classification System levels I (limitations in advanced

  16. Test-Retest Reliability of the 20-sec Wingate Test to Assess Anaerobic Power in Children with Cerebral Palsy

    NARCIS (Netherlands)

    Dallmeijer, Annet J.; Scholtes, Vanessa A. B.; Brehm, Merel-Anne; Becher, Jules G.

    2013-01-01

    Objective: The aim of this study was to determine the test-retest reliability of the 20-sec Wingate anaerobic test in children with cerebral palsy. Design: Participants were 22 ambulant children with cerebral palsy, with Gross Motor Function Classification System levels I (limitations in advanced

  17. Updated Results of Ultrasonic Transducer Irradiation Test

    Energy Technology Data Exchange (ETDEWEB)

    Daw, Joshua; Palmer, Joe [Idaho National Laboratory, P.O. Box 1625, MS 4112, Idaho Falls, ID, 38415-3840 (United States); Ramuhalli, Pradeep; Keller, Paul; Montgomery, Robert [Pacific Northwest National Laboratory, 902 Battelle Blvd. Richland, WA, 99354 (United States); Chien, Hual-Te [Argonne National Laboratory, 9700 S. Cass Avenue Argonne, IL, 60439 (United States); Tittmann, Bernhard; Reinhardt, Brian [Pennsylvania State University, 212 Earth and Engr. Sciences Building, University Park, PA, 16802 (United States); Kohse, Gordon [Massachusetts Institute of Technology, 77 Massachusetts Ave. Cambridge, MA 02139 (United States); Rempe, Joy [Rempe and Associates, LLC, 360 Stillwater, Idaho Falls, ID 83404 (United States); Villard, J.F. [Commissariat a l' energie atomique et aux energies alternatives, Centre d' etudes de Cadarache, 13108 Saint-Paul-lez-Durance (France)

    2015-07-01

    Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 10{sup 21} n/cm{sup 2}. A multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET-ASI) program also provided initial support for this effort. This irradiation, which started in February 2014, is an instrumented lead test and real-time transducer performance data are collected along with temperature and neutron and gamma flux data. The irradiation is ongoing and will continue to approximately mid-2015. To date, very encouraging results have been attained as several transducers continue to operate under irradiation. (authors)

  18. Use of a valve operation test and evaluation system to enhance valve reliability

    International Nuclear Information System (INIS)

    Lowry, D.A.

    1990-01-01

    Power plant owners have emphasized the need for assuring safe, reliable operation of valves. While most valves must simply open or close, the mechanisms involved can be quite complex. Motor operated valves (MOVs) must be properly adjusted to assure operability. Individual operator components determine the performance of the entire MOV. Failure in MOVs could cripple or shut down a unit. Thus, a complete valve program consisting of design reviews, operational testing, and preventive and predictive maintenance activities will enhance an owner's confidence level that his valves win operate as expected. Liberty's Valve Operation Test and Evaluation System (VOTES) accurately measures stein thrust without intruding on valve operation. Since mounting a strain gage to a valve stem is a desirable but impractical way of obtaining precise stem thrust, Liberty developed a method to obtain identical data by placing a strain gage sensor on the valve yoke. VOTES provides information which effectively eliminates costly, unscheduled downtime. This paper presents the results of infield VOTES testing. The system's proven ability to identify and characterize actuator and valve performance is demonstrated. Specific topics of discussion include the ability of VOTES to ease a utility's IE Bulletin 8543 concerns and conclusively diagnose MOV components. Data from static and differential pressure testing are presented. Technical, operational, and financial advantages resulting from VOTES technology are explored in detail

  19. Validation and Reliability of a Novel Test of Upper Body Isometric Strength

    Directory of Open Access Journals (Sweden)

    Bellar David

    2015-09-01

    Full Text Available The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4% volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a “push-up” style position while tethered (stainless steel chain to a load cell (high frequency anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98 suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001 with all predictor variables attaining significance in the model (p<0.05. Isometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001. Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment.

  20. Validation and Reliability of a Novel Test of Upper Body Isometric Strength.

    Science.gov (United States)

    Bellar, David; Marcus, Lena; Judge, Lawrence W

    2015-09-29

    The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4%) volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a "push-up" style position while tethered (stainless steel chain) to a load cell (high frequency) anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98) suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001) with all predictor variables attaining significance in the model (pIsometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001). Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment.

  1. Validation and Reliability of a Novel Test of Upper Body Isometric Strength

    Science.gov (United States)

    Bellar, David; Marcus, Lena; Judge, Lawrence W.

    2015-01-01

    The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4%) volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a “push-up” style position while tethered (stainless steel chain) to a load cell (high frequency) anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98) suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001) with all predictor variables attaining significance in the model (p<0.05). Isometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001). Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment. PMID:26557203

  2. Orthopaedic nurses' knowledge and interrater reliability of neurovascular assessments with 2-point discrimination test.

    Science.gov (United States)

    Turney, Jennifer; Raley Noble, Deana; Kim, Son Chae

    2013-01-01

    : This study was conducted to evaluate the effects of education on knowledge and interrater reliability of neurovascular assessments with 2-point discrimination (2-PD) test among pediatric orthopaedic nurses. : A pre- and posttest study was done among 60 nurses attending 2-hour educational sessions. Neurovascular assessments with 2-PD test were performed on 64 casted pediatric patients by the nurses and 5 nurse experts before and after the educational sessions. : The mean neurovascular assessment knowledge score was improved at posteducation compared with the preeducation (p < .001). The 2-PD test interrater reliability also improved from Cohen's kappa value of 0.24-0.48 at posteducation. : The 2-hour educational session may be effective in improving nurses' knowledge and the interrater reliability of neurovascular assessment with 2-PD test.

  3. Study of Optimal Perimetric Testing in Children (OPTIC: Feasibility, Reliability and Repeatability of Perimetry in Children.

    Directory of Open Access Journals (Sweden)

    Dipesh E Patel

    Full Text Available To investigate feasibility, reliability and repeatability of perimetry in children.A prospective, observational study recruiting 154 children aged 5-15 years, without an ophthalmic condition that affects the visual field (controls, identified consecutively between May 2012 and November 2013 from hospital eye clinics. Perimetry was undertaken in a single sitting, with standardised protocols, in a randomised order using the Humphrey static (SITA 24-2 FAST, Goldmann and Octopus kinetic perimeters. Data collected included test duration, subjective experience and test quality (incorporating examiner ratings on comprehension of instructions, fatigue, response to visual and auditory stimuli, concentration and co-operation to assess feasibility and reliability. Testing was repeated within 6 months to assess repeatability.Overall feasibility was very high (Goldmann=96.1%, Octopus=89% and Humphrey=100% completed the tests. Examiner rated reliability was 'good' in 125 (81.2% children for Goldmann, 100 (64.9% for Octopus and 98 (63.6% for Humphrey perimetry. Goldmann perimetry was the most reliable method in children under 9 years of age. Reliability improved with increasing age (multinomial logistic regression (Goldmann, Octopus and Humphrey, p<0.001. No significant differences were found for any of the three test strategies when examining initial and follow-up data outputs (Bland-Altman plots, n=43, suggesting good test repeatability, although the sample size may preclude detection of a small learning effect.Feasibility and reliability of formal perimetry in children improves with age. By the age of 9 years, all the strategies used here were highly feasible and reliable. Clinical assessment of the visual field is achievable in children as young as 5 years, and should be considered where visual field loss is suspected. Since Goldmann perimetry is the most effective strategy in children aged 5-8 years and this perimeter is no longer available, further

  4. Operationalization and reliability testing of ICF categories relevant for physiotherapists' interventions in the acute hospital

    OpenAIRE

    Grill, E; Gloor-Juzi, T; Huber, E O; Stucki, G

    2011-01-01

    Objective: To operationalize items based on categories of the International Classification of Functioning, Disability and Health (ICF) relevant to patient problems that are addressed by physiotherapeutic interventions in the acute hospital, and to test the reliability of these items when applied by physiotherapists. Methods: A selection of 124 ICF categories was operationalized in a formal decision-making and consensus process. The reliability of the newly operationalized item list ...

  5. Reliability and Validity of the New Tanaka B Intelligence Scale Scores: A Group Intelligence Test

    OpenAIRE

    Uno, Yota; Mizukami, Hitomi; Ando, Masahiko; Yukihiro, Ryoji; Iwasaki, Yoko; Ozaki, Norio

    2014-01-01

    OBJECTIVE: The present study evaluated the reliability and concurrent validity of the new Tanaka B Intelligence Scale, which is an intelligence test that can be administered on groups within a short period of time. METHODS: The new Tanaka B Intelligence Scale and Wechsler Intelligence Scale for Children-Third Edition were administered to 81 subjects (mean age ± SD 15.2 ± 0.7 years) residing in a juvenile detention home; reliability was assessed using Cronbach's alpha coefficient, and concurre...

  6. Evaluating the reliability of an injury prevention screening tool: Test-retest study.

    Science.gov (United States)

    Gittelman, Michael A; Kincaid, Madeline; Denny, Sarah; Wervey Arnold, Melissa; FitzGerald, Michael; Carle, Adam C; Mara, Constance A

    2016-10-01

    A standardized injury prevention (IP) screening tool can identify family risks and allow pediatricians to address behaviors. To assess behavior changes on later screens, the tool must be reliable for an individual and ideally between household members. Little research has examined the reliability of safety screening tool questions. This study utilized test-retest reliability of parent responses on an existing IP questionnaire and also compared responses between household parents. Investigators recruited parents of children 0 to 1 year of age during admission to a tertiary care children's hospital. When both parents were present, one was chosen as the "primary" respondent. Primary respondents completed the 30-question IP screening tool after consent, and they were re-screened approximately 4 hours later to test individual reliability. The "second" parent, when present, only completed the tool once. All participants received a 10-dollar gift card. Cohen's Kappa was used to estimate test-retest reliability and inter-rater agreement. Standard test-retest criteria consider Kappa values: 0.0 to 0.40 poor to fair, 0.41 to 0.60 moderate, 0.61 to 0.80 substantial, and 0.81 to 1.00 as almost perfect reliability. One hundred five families participated, with five lost to follow-up. Thirty-two (30.5%) parent dyads completed the tool. Primary respondents were generally mothers (88%) and Caucasian (72%). Test-retest of the primary respondents showed their responses to be almost perfect; average 0.82 (SD = 0.13, range 0.49-1.00). Seventeen questions had almost perfect test-retest reliability and 11 had substantial reliability. However, inter-rater agreement between household members for 12 objective questions showed little agreement between responses; inter-rater agreement averaged 0.35 (SD = 0.34, range -0.19-1.00). One question had almost perfect inter-rater agreement and two had substantial inter-rater agreement. The IP screening tool used by a single individual had excellent

  7. Test-retest reliability of Eurofit Physical Fitness items for children with visual impairments

    NARCIS (Netherlands)

    Houwen, Suzanne; Visscher, Chris; Hartman, Esther; Lemmink, Koen A. P. M.

    The purpose of this study was to examine the test-retest reliability of physical fitness items from the European Test of Physical Fitness (Eurofit) for children with visual impairments. A sample of 21 children, ages 6-12 years, that were recruited from a special school for children with visual

  8. Feasibility and Reliability of Two Different Walking Tests in People With Severe Intellectual and Sensory Disabilities

    NARCIS (Netherlands)

    Waninge, Aly; Evenhuis, I.E.; Van Wijck, R.; van der Schans, Cees

    2011-01-01

    Background  The purpose of this study is to describe feasibility and test–retest reliability of the six-minute walking distance test (6MWD) and an adapted shuttle run test (aSRT) in persons with severe intellectual and sensory (multiple) disabilities. Materials and Methods  Forty-seven persons with

  9. Test-retest, inter-assessor and intra-assessor reliability of the modified Touwen examination

    NARCIS (Netherlands)

    Peters, Lieke H. J.; Maathuis, Karel G. B.; Kouw, Eva; Hamming, Marjolein; Hadders-Algra, Mijna

    Interest in the Touwen examination (1979) for the assessment of minor neurological dysfunction (MND) is growing. However, information on psychometric properties of this assessment is scarce. Therefore the present study aimed at assessing the test's test-retest, inter- and intra-assessor reliability.

  10. Reliability and feasibility of the six minute walk test in subjects with myotonic dystrophy.

    Science.gov (United States)

    Kierkegaard, Marie; Tollbäck, Anna

    2007-12-01

    The objective was to describe test-retest reliability and feasibility of the six minute walk test in adult subjects with myotonic dystrophy type 1. Twelve subjects (28-68 years, mean 44) performed three six minute walk tests on two occasions, one week apart. Relative reliability was high (ICC(2.1)=0.99) and absolute reliability values were low (standard error of measurement 12 m, repeatability 33 m). Feasibility was investigated in a sample of 64 subjects (19-70 years, mean 43). Fifty-two subjects were able to perform two tests on the same day. Subjects with severe proximal weakness had difficulties performing repeated tests. A practice trial followed by a second test on the same day can be recommended for most subjects, and the best test should be used for evaluations. In conclusion, even though the study sample was small, the present study indicates that the six minute walk test is reliable and feasible in subjects with myotonic dystrophy type 1.

  11. Test-retest reliability of the isernhagen work systems functional capacity evaluation in healthy adults

    NARCIS (Netherlands)

    Reneman, MF; Brouwer, S; Meinema, A; Dijkstra, PU; Geertzen, JHB; Groothoff, JW

    2004-01-01

    Aim of this study was to investigate test-retest reliability of the Isernhagen Work System Functional Capacity Evaluation (IWS FCE) in healthy subjects. The IWS FCE consists of 28 tests that reflect work-related activities such as lifting, carrying, bending, etc. A convenience sample of 26 healthy

  12. reliability reliability

    African Journals Online (AJOL)

    eobe

    Corresponding author, Tel: +234-703. RELIABILITY .... V , , given by the code of practice. However, checks must .... an optimization procedure over the failure domain F corresponding .... of Concrete Members based on Utility Theory,. Technical ...

  13. Is the Bayley Scales of Infant and Toddler Developmental Screening Test, Valid and Reliable for Persian Speaking Children?

    Science.gov (United States)

    Soleimani, Farin; Azari, Nadia; Vameghi, Roshanak; Sajedi, Firoozeh; Shahshahani, Soheila; Karimi, Hossein; Kraskian, Adis; Shahrokhi, Amin; Teymouri, Robab; Gharib, Masoud

    2016-10-01

    Advances in perinatal and neonatal care have substantially improved the survival of at-risk infants over the past two decades. The purpose of this study was to assess the reliability and validity of the Bayley Scales of infant and toddler developmental Screening test in Persian-speaking children. This was a cross-sectional prospective study of 403 children aged 1 - 42-months. The Bayley scales screening instrument, which consists of five domains (cognitive, receptive, and expressive communication and fine and gross motor items), was used to measure infants' and toddlers' development. The psychometric properties examined included the face and content validity of the scale, in addition to cultural and linguistic modifications to the scale and its test-retest and inter-rater reliability. An expert team changed some of the test items relating to cultural and linguistic issues. In almost all the age groups, cultural or linguistic changes were made to items in the communication domains. According to Cronbach's alpha for internal consistency, the reliability of the cognitive scale was r = 0.79, and the reliability of the receptive scale was r = 0.76. The reliability for expressive communication, fine motor, and gross motor scales was r = 0.81, r = 0.80, and r = 0.81, respectively. The construct validity of the tests was confirmed using a factor analysis and comparison of the mean scores of the age groups. The intra- and inter-rater reliabilities of the Bayley Scales were good-to-excellent. The results indicated that the Bayley Scales had a high level of reliability in the present study. Thus, the scale can be used in a Persian population.

  14. Comparison of the reliability of parental reporting and the direct test of the Thai Speech and Language Test.

    Science.gov (United States)

    Prathanee, Benjamas; Angsupakorn, Nipa; Pumnum, Tawitree; Seepuaham, Cholada; Jaiyong, Pechcharat

    2012-11-01

    To find reliability of parental or caregiver's report and testing of the Thai Speech and Language Test for Children Aged 0-4 Years Old. Five investigators assessed speech and language abilities from video both contexts: parental or caregivers' report and test forms of Thai Speech and Language Test for Children Aged 0-4 Years Old. Twenty-five normal and 30 children with delayed development or risk for delayed speech and language skills were assessed at age intervals of 3, 6, 9, 12, 15, 18, 24, 30, 36 and 48 months. Reliability of parental or caregivers' testing and reporting was at a moderate level (0.41-0.60). Inter-rater reliability among investigators was excellent (0.86-1.00). The parental or caregivers' report form of the Thai Speech and Language test for Children aged 0-4 years old was an indicator for success at a moderate level. Trained professionals could use both forms of this test as reliable tools at an excellent level.

  15. Feasibility and test-retest reliability of measuring lower‑limb strength in young children with cerebral palsy.

    Science.gov (United States)

    Van Vulpen, L F; De Groot, S; Becher, J G; De Wolf, G S; Dallmeijer, A J

    2013-12-01

    Quantifying leg muscle strength in young children with cerebral palsy (CP) is essential for identifying muscle groups for treatment and for monitoring progress. To study the feasibility, intratester reliability and the optimal test design (number of test occasions and repetitions) of measuring lower-limb strength with handheld dynamometry (HHD) and dynamic ankle plantar flexor strength with the standing heel-rise (SH) test in 3-10 year aged children with CP. Test-retest design. Rehabilitation centre, special needs school for children with disabilities, and university medical centre. Knee extensor, hip abductor and calf muscle strength was assessed in 20 ambulatory children with spastic CP (3-5 years [N.=10] and 6-10 years [N.=10]) on two test occasions. Intraclass correlation coefficients (ICC) and Smallest Detectable Differences (SDD) were calculated to determine the optimal test design for detecting changes in strength. All isometric strength tests had acceptable SDDs (9-30%), when taking the mean values of 2-3 test occasions (separate days) and 2-3 repetitions. The one-leg SH test had large SDDs (40-128% for younger group, 23-48% for older group). Isometric strength (improvements) can only be measured reliably with HHD in young children with CP when the average values over at least 2 test occasions are taken. Reliability of the SH test is not sufficient for measuring individual changes in dynamic muscle strength in the younger children. Results of this study can be used to determine the optimal number of test occasions and repetitions for reliable HHD measurements depending on expected changes, muscle group and age in 3-10 year old children with CP.

  16. Results from the Cooler and Lead Tests

    International Nuclear Information System (INIS)

    Green, Michael A.

    2010-01-01

    The report presents the results of testing MICE spectrometer magnet current leads on a test apparatus that combines both the copper leads and the high temperature superconducting (HTS) leads with a single Cryomech PT415 cooler and liquid helium tank. The current is carried through the copper leads from 300 K to the top of the HTS leads. The current is then carried through the HTS leads to a feed-through from the vacuum space to the inside of a liquid helium tank. The experiment allows one to measure the performance of both cooler stages along with the performance of the leads. While the leads were powered we measured the voltage drops through the copper leads, through the HTS leads, through spliced to the feed-through, through the feed-through and through the low-temperature superconducting loop that connects one lead to the other. Measurements were made using the leads that were used in spectrometer magnet 1A and spectrometer magnet 2A. These are the same leads that were used for Superbend and Venus magnets at LBNL. The IL/A for these leads was 5.2 x 10 6 m -1 . The leads turned out to be too long. The same measurements were made using the leads that were installed in magnet 2B. The magnet 2B leads had an IL/A of 3.3 x 10 6 A m -1 . This report discusses the cooler performance and the measured electrical performance of the lead circuit that contains the copper leads and the superconducting leads. All of the HTS leads that were installed in magnet 2B were current tested using this apparatus.

  17. Tuned Chamber Core Panel Acoustic Test Results

    Science.gov (United States)

    Schiller, Noah H.; Allen, Albert R.

    2016-01-01

    This report documents acoustic testing of tuned chamber core panels, which can be used to supplement the low-frequency performance of conventional acoustic treatment. The tuned chamber core concept incorporates low-frequency noise control directly within the primary structure and is applicable to sandwich constructions with a directional core, including corrugated-, truss-, and fluted-core designs. These types of sandwich structures have long, hollow channels (or chambers) in the core. By adding small holes through one of the facesheets, the hollow chambers can be utilized as an array of low-frequency acoustic resonators. These resonators can then be used to attenuate low-frequency noise (below 400 Hz) inside a vehicle compartment without increasing the weight or size of the structure. The results of this test program demonstrate that the tuned chamber core concept is effective when used in isolation or combined with acoustic foam treatments. Specifically, an array of acoustic resonators integrated within the core of the panels was shown to improve both the low-frequency absorption and transmission loss of the structure in targeted one-third octave bands.

  18. The minimum sit-to-stand height test: reliability, responsiveness and relationship to leg muscle strength.

    Science.gov (United States)

    Schurr, Karl; Sherrington, Catherine; Wallbank, Geraldine; Pamphlett, Patricia; Olivetti, Lynette

    2012-07-01

    To determine the reliability of the minimum sit-to-stand height test, its responsiveness and its relationship to leg muscle strength among rehabilitation unit inpatients and outpatients. Reliability study using two measurers and two test occasions. Secondary analysis of data from two clinical trials. Inpatient and outpatient rehabilitation services in three public hospitals. Eighteen hospital patients and five others participated in the reliability study. Seventy-two rehabilitation unit inpatients and 80 outpatients participated in the clinical trials. The minimum sit-to-stand height test was assessed using a standard procedure. For the reliability study, a second tester repeated the minimum sit-to-stand height test on the same day. In the inpatient clinical trial the measures were repeated two weeks later. In the outpatient trial the measures were repeated five weeks later. Knee extensor muscle strength was assessed in the clinical trials using a hand-held dynamometer. The reliability for the minimum sit-to-stand height test was excellent (intraclass correlation coefficient (ICC) 0.91, 95% confidence interval (CI) 0.81-0.96). The standard error of measurement was 34 mm. Responsiveness was moderate in the inpatient trial (effect size: 0.53) but small in the outpatient trial (effect size: 0.16). A small proportion (8-17%) of variability in minimum sit-to-stand height test was explained by knee extensor muscle strength. The minimum sit-to-stand height test has excellent reliability and moderate responsiveness in an inpatient rehabilitation setting. Responsiveness in an outpatient rehabilitation setting requires further investigation. Performance is influenced by factors other than knee extensor muscle strength.

  19. Evaluating abdominal core muscle fatigue: Assessment of the validity and reliability of the prone bridging test.

    Science.gov (United States)

    De Blaiser, C; De Ridder, R; Willems, T; Danneels, L; Vanden Bossche, L; Palmans, T; Roosen, P

    2018-02-01

    The aims of this study were to research the amplitude and median frequency characteristics of selected abdominal, back, and hip muscles of healthy subjects during a prone bridging endurance test, based on surface electromyography (sEMG), (a) to determine if the prone bridging test is a valid field test to measure abdominal muscle fatigue, and (b) to evaluate if the current method of administrating the prone bridging test is reliable. Thirty healthy subjects participated in this experiment. The sEMG activity of seven abdominal, back, and hip muscles was bilaterally measured. Normalized median frequencies were computed from the EMG power spectra. The prone bridging tests were repeated on separate days to evaluate inter and intratester reliability. Significant differences in normalized median frequency slope (NMF slope ) values between several abdominal, back, and hip muscles could be demonstrated. Moderate-to-high correlation coefficients were shown between NMF slope values and endurance time. Multiple backward linear regression revealed that the test endurance time could only be significantly predicted by the NMF slope of the rectus abdominis. Statistical analysis showed excellent reliability (ICC=0.87-0.89). The findings of this study support the validity and reliability of the prone bridging test for evaluating abdominal muscle fatigue. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Development and interrater reliability testing of a telephone interview training programme for Australian nurse interviewers.

    Science.gov (United States)

    Ahern, Tracey; Gardner, Anne; Gardner, Glenn; Middleton, Sandy; Della, Phillip

    2013-05-01

    The final phase of a three phase study analysing the implementation and impact of the nurse practitioner role in Australia (the Australian Nurse Practitioner Project or AUSPRAC) was undertaken in 2009, requiring nurse telephone interviewers to gather information about health outcomes directly from patients and their treating nurse practitioners. A team of several registered nurses was recruited and trained as telephone interviewers. The aim of this paper is to report on development and evaluation of the training process for telephone interviewers. The training process involved planning the content and methods to be used in the training session; delivering the session; testing skills and understanding of interviewers post-training; collecting and analysing data to determine the degree to which the training process was successful in meeting objectives and post-training follow-up. All aspects of the training process were informed by established educational principles. Interrater reliability between interviewers was high for well-validated sections of the survey instrument resulting in 100% agreement between interviewers. Other sections with unvalidated questions showed lower agreement (between 75% and 90%). Overall the agreement between interviewers was 92%. Each interviewer was also measured against a specifically developed master script or gold standard and for this each interviewer achieved a percentage of correct answers of 94.7% or better. This equated to a Kappa value of 0.92 or better. The telephone interviewer training process was very effective and achieved high interrater reliability. We argue that the high reliability was due to the use of well validated instruments and the carefully planned programme based on established educational principles. There is limited published literature on how to successfully operationalise educational principles and tailor them for specific research studies; this report addresses this knowledge gap. Copyright © 2012 Elsevier

  1. Selected problems and results of the transient event and reliability analyses for the German safety study

    International Nuclear Information System (INIS)

    Hoertner, H.

    1977-01-01

    For the investigation of the risk of nuclear power plants loss-of-coolant accidents and transients have to be analyzed. The different functions of the engineered safety features installed to cope with transients are explained. The event tree analysis is carried out for the important transient 'loss of normal onsite power'. Preliminary results of the reliability analyses performed for quantitative evaluation of this event tree are shown. (orig.) [de

  2. Field Lysimeter Test Facility: Second year (FY 1989) test results

    International Nuclear Information System (INIS)

    Campbell, M.D.; Gee, G.W.; Kanyid, M.J.; Rockhold, M.L.

    1990-04-01

    The Record of Decision associated with the Hanford Defense Waste Environmental Impact Statement (53 FR 12449-53) commits to an evaluation of the use of protective barriers placed over near-surface wastes. The barrier must protect against wind and water erosion and limit plant and animal intrusion and infiltration of water. Successful conclusion of this program will yield the necessary protective barrier design for near-surface waste isolation. This report presents results from the second year of tests at the FLTF. The primary objective of testing protective barriers at the FLTF was to measure the water budgets within the various barriers and assess the effectiveness of their designs in limiting water intrusion into the zone beneath each barrier. Information obtained from these measurements is intended for use in refining barrier designs. Four elements of water budget were measured during the year: precipitation, evaporation, storage, and drainage. Run-off, which is a fifth element of a complete water budget, was made negligible by a lip on the lysimeters that protrudes 5 cm above the soil surface to prevent run-off. A secondary objective of testing protective barriers at the FLTF was to refine procedures and equipment to support data collection for verification of the computer model needed for long-term projections of barrier performance. 6 refs

  3. A Systematic Review of the Reliability and Validity of Behavioural Tests Used to Assess Behavioural Characteristics Important in Working Dogs.

    Science.gov (United States)

    Brady, Karen; Cracknell, Nina; Zulch, Helen; Mills, Daniel Simon

    2018-01-01

    Working dogs are selected based on predictions from tests that they will be able to perform specific tasks in often challenging environments. However, withdrawal from service in working dogs is still a big problem, bringing into question the reliability of the selection tests used to make these predictions. A systematic review was undertaken aimed at bringing together available information on the reliability and predictive validity of the assessment of behavioural characteristics used with working dogs to establish the quality of selection tests currently available for use to predict success in working dogs. The search procedures resulted in 16 papers meeting the criteria for inclusion. A large range of behaviour tests and parameters were used in the identified papers, and so behaviour tests and their underpinning constructs were grouped on the basis of their relationship with positive core affect (willingness to work, human-directed social behaviour, object-directed play tendencies) and negative core affect (human-directed aggression, approach withdrawal tendencies, sensitivity to aversives). We then examined the papers for reports of inter-rater reliability, within-session intra-rater reliability, test-retest validity and predictive validity. The review revealed a widespread lack of information relating to the reliability and validity of measures to assess behaviour and inconsistencies in terminologies, study parameters and indices of success. There is a need to standardise the reporting of these aspects of behavioural tests in order to improve the knowledge base of what characteristics are predictive of optimal performance in working dog roles, improving selection processes and reducing working dog redundancy. We suggest the use of a framework based on explaining the direct or indirect relationship of the test with core affect.

  4. MIDAS and HIT-6 French translation: reliability and correlation between tests.

    Science.gov (United States)

    Magnoux, E; Freeman, M A; Zlotnik, G

    2008-01-01

    The aim was to evaluate the test-retest reliability of the French translation of the Migraine Disability Assessment (MIDAS) and Headache Impact Test (HIT)-6 questionnaires as applied to episodic and chronic headaches and to assess the correlation between these two questionnaires. The MIDAS and HIT-6 questionnaires, which assess the degree of migraine-related functional disability, are widely used in headache treatment clinics. The French translation has not been checked for test-retest reliability. MIDAS involves recall, over the previous 3 months, of the number of days with functional disability with regard to work and to home and social life. HIT-6 involves a more subjective and general assessment of headache-related disability over the previous 4 weeks. We expect that there may be greater impact recall bias for chronic headaches than for episodic headaches and considered it important to be able to determine if the reliability of these questionnaires is equally good for these two patient populations. Given that both questionnaires have the same objective, that of assessing headache impact, it was thought useful to determine if their results might show a correlation and if they could thus be used interchangeably. The study was approved by an external ethics committee. The subjects were patients who regularly visit the Clinique de la Migraine de Montréal, which specializes in the treatment of headaches. The MIDAS and HIT-6 questionnaires were completed by the patients during their regular visit. Twelve days later, the same questionnaires were mailed with a prepaid return envelope. Sixty-five patients were required in both the episodic and chronic headache groups, assuming an 80% questionnaire return rate. One hundred and eighty-five patients were enrolled, and 143 completed the study, 75 with episodic headaches and 68 with chronic headaches. The questionnaire return rate was 78.9%. On average, questionnaires were completed a second time 21 days after the first

  5. Vertical jumping tests in volleyball: reliability, validity, and playing-position specifics.

    Science.gov (United States)

    Sattler, Tine; Sekulic, Damir; Hadzic, Vedran; Uljevic, Ognjen; Dervisevic, Edvin

    2012-06-01

    Vertical jumping is known to be important in volleyball, and jumping performance tests are frequently studied for their reliability and validity. However, most studies concerning jumping in volleyball have dealt with standard rather than sport-specific jumping procedures and tests. The aims of this study, therefore, were (a) to determine the reliability and factorial validity of 2 volleyball-specific jumping tests, the block jump (BJ) test and the attack jump (AJ) test, relative to 2 frequently used and systematically validated jumping tests, the countermovement jump test and the squat jump test and (b) to establish volleyball position-specific differences in the jumping tests and simple anthropometric indices (body height [BH], body weight, and body mass index [BMI]). The BJ was performed from a defensive volleyball position, with the hands positioned in front of the chest. During an AJ, the players used a 2- to 3-step approach and performed a drop jump with an arm swing followed by a quick vertical jump. A total of 95 high-level volleyball players (all men) participated in this study. The reliability of the jumping tests ranged from 0.97 to 0.99 for Cronbach's alpha coefficients, from 0.93 to 0.97 for interitem correlation coefficients and from 2.1 to 2.8 for coefficients of variation. The highest reliability was found for the specific jumping tests. The factor analysis extracted one significant component, and all of the tests were highly intercorrelated. The analysis of variance with post hoc analysis showed significant differences between 5 playing positions in some of the jumping tests. In general, receivers had a greater jumping capacity, followed by libero players. The differences in jumping capacities should be emphasized vis-a-vis differences in the anthropometric measures of players, where middle hitters had higher BH and body weight, followed by opposite hitters and receivers, with no differences in the BMI between positions.

  6. Attentional and visual demands for sprint performance in non-fatigued and fatigued conditions: reliability of a repeated sprint test

    Directory of Open Access Journals (Sweden)

    Diercks Ron L

    2010-05-01

    Full Text Available Abstract Background Physical performance measures are widely used to assess physical function, providing information about physiological and biomechanical aspects of motor performance. However they do not provide insight into the attentional and visual demands for motor performance. A figure-of-eight sprint test was therefore developed to measure the attentional and visual demands for repeated-sprint performance. The aims of the study were: 1 to assess test-retest reliability of the figure-of-eight sprint test, and 2 to study the attentional and visual demands for sprint performance in a non-fatigued and fatigued condition. Methods Twenty-seven healthy athletes were included in the study. To determine test-retest reliability, a subgroup of 19 athletes performed the figure-of-eight sprint test twice. The figure-of-eight sprint test consisted of nine 30-second sprints. The sprint test consisted of three test parts: sprinting without any restriction, with an attention-demanding task, and with restricted vision. Increases in sprint times with the attention-demanding task or restricted vision are reflective of the attentional and visual demands for sprinting. Intraclass correlation coefficients (ICCs and mean difference between test and retest with 95% confidence limits (CL were used to assess test-retest reliability. Repeated-measures ANOVA were used for comparisons between the sprint times and fatigue measurements of the test parts in both a non-fatigued and fatigued condition. Results The figure-of-eight sprint test showed good test-retest reliability, with ICCs ranging from 0.75 to 0.94 (95% CL: 0.40-0.98. Zero lay within the 95% CL of the mean differences, indicating that no bias existed between sprint performance at test and retest. Sprint times during the test parts with attention-demanding task (P = 0.01 and restricted vision (P Conclusions High ICCs and the absence of systematic variation indicate good test-retest reliability of the figure

  7. The Validity and Reliability Test of the Indonesian Version of Gastroesophageal Reflux Disease Quality of Life (GERD-QOL) Questionnaire.

    Science.gov (United States)

    Siahaan, Laura A; Syam, Ari F; Simadibrata, Marcellus; Setiati, Siti

    2017-01-01

    to obtain a valid and reliable GERD-QOL questionnaire for Indonesian application. at the initial stage, the GERD-QOL questionnaire was first translated into Indonesian language and the translated questionnaire was subsequently translated back into the original language (back-to-back translation). The results were evaluated by the researcher team and therefore, an Indonesian version of GERD-QOL questionnaire was developed. Ninety-one patients who had been clinically diagnosed with GERD based on the Montreal criteria were interviewed using the Indonesian version of GERD-QOL questionnaire and the SF 36 questionnaire. The validity was evaluated using a method of construct validity and external validity, and reliability can be tested by the method of internal consistency and test retest. the Indonesian version of GERD-QOL questionnaire had a good internal consistency reliability with a Cronbach Alpha of 0.687-0.842 and a good test retest reliability with an intra-class correlation coefficient of 0.756-0.936; pGERD-QOL questionnaire has been proven valid and reliable to evaluate the quality of life of GERD patients.

  8. The six-item Clock Drawing Testreliability and validity in mild Alzheimer’s disease

    DEFF Research Database (Denmark)

    Jørgensen, Kasper; Kristensen, Maria K; Waldemar, Gunhild

    2015-01-01

    This study presents a reliable, short and practical version of the Clock Drawing Test (CDT) for clinical use and examines its diagnostic accuracy in mild Alzheimer's disease versus elderly nonpatients. Clock drawings from 231 participants were scored independently by four clinical neuropsychologi......This study presents a reliable, short and practical version of the Clock Drawing Test (CDT) for clinical use and examines its diagnostic accuracy in mild Alzheimer's disease versus elderly nonpatients. Clock drawings from 231 participants were scored independently by four clinical...... neuropsychologists blind to diagnostic classification. The interrater agreement of individual scoring criteria was analyzed and items with poor or moderate reliability were excluded. The classification accuracy of the resulting scoring system - the six-item CDT - was examined. We explored the effect of further...

  9. Interrater reliability of the Volume-Viscosity Swallow Test; screening for dysphagia among hospitalized elderly medical patients.

    Science.gov (United States)

    Jørgensen, Lise Walther; Søndergaard, Kasper; Melgaard, Dorte; Warming, Susan

    2017-12-01

    Oropharyngeal dysphagia (OD) is prevalent among medical and geriatric patients admitted due to acute illness and it is associated with malnutrition, increased length of stay and increased mortality. A valid and reliable bedside screening test for patients at risk of OD is essential in order to detect patients in need of further assessment. The Volume-Viscosity Swallow Test (V-VST) has been shown to be a valid screening test for OD in mixed outpatient populations. However, as reliability of the test has yet to be investigated in a population of medical and geriatric patients admitted due to acute illness, we aimed to determine the interrater reliability of the V-VST in this clinical setting. Reporting in this study is in accordance with proposed guidelines for the reporting of reliability and agreement studies (GRRAS). In three Danish hospitals (CRD-BFH, CRD-GH, NDR-H) 11 skilled occupational therapists examined an unselected group of 110 patients admitted to geriatric or medical wards. In an overall agreement phase raters reached ≥80% agreement before data collection phase was commenced. The V-VST was applied to patients twice within maximum one hour by raters who administrated the test in an order based on randomization, blinded to each other's results. Agreement, Kappa values, weighed Kappa values and Kappa adjusted for bias and prevalence are reported. The interrater reliability of V-VST as screening test for OD in patients admitted to geriatric or medical wards was substantial with an overall Kappa value of 0.77 (95% CI 0.65-0.89) however interrater reliability varied among hospitals ranging from 0.37 (95% CI -0.01 to 0.41) to 0.85 (95% CI 0.75-1.00). Interrater reliability of the accompanying recommendations of volume and viscosity was moderate with a weighted kappa value of 0.55 (95% CI 0.37-0.73) for viscosity and 0.53 (95% CI 0.36-0.7) for volume. The overall prevalence of OD was 34.5%, ranging from 8% to 53.6% across hospitals. The prevalence and bias

  10. Intra-tester Reliability and Construct Validity of a Hip Abductor Eccentric Strength Test.

    Science.gov (United States)

    Brindle, Richard A; Ebaugh, D David; Milner, Clare E

    2017-11-15

    Side-lying hip abductor strength tests are commonly used to evaluate muscle strength. In a 'break' test the tester applies sufficient force to lower the limb to the table while the patient resists. The peak force is postulated to occur while the leg is lowering, thus representing the participant's eccentric muscle strength. However, it is unclear whether peak force occurs before or after the leg begins to lower. To determine intra-rater reliability and construct validity of a hip abductor eccentric strength test. Intra-rater reliability and construct validity study. Twenty healthy adults (26 ±6 years; 1.66 ±0.06 m; 62.2 ±8.0 kg) made two visits to the laboratory at least one week apart. During the hip abductor eccentric strength test, a hand-held dynamometer recorded peak force and time to peak force and limb position was recorded via a motion capture system. Intra-rater reliability was determined using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable difference (MDD). Construct validity was assessed by determining if peak force occurred after the start of the lowering phase using a one-sample t-test. The hip abductor eccentric strength test had substantial intra-rater reliability (ICC( 3,3 ) = 0.88; 95% confidence interval: 0.65-0.95), SEM of 0.9%BWh, and a MDD of 2.5%BWh. Construct validity was established as peak force occurred 2.1s (±0.6s; range 0.7s to 3.7s) after the start of the lowering phase of the test (p ≤ 0.001). The hip abductor eccentric strength test is a valid and reliable measure of eccentric muscle strength. This test may be used clinically to assess changes in eccentric muscle strength over time.

  11. The Functional Test for Agility Performance is a Reliable Quick Decision-Making Test for Skilled Water Polo Players

    Directory of Open Access Journals (Sweden)

    Tucher Guilherme

    2015-06-01

    Full Text Available The reliability of the Functional Test for Agility Performance has only been evaluated in water polo players in a small group of novice athletes. Thus, the aim of this study was to evaluate the reliability of the Functional Test for Agility Performance in skilled water polo players. Forty-two athletes (17.81 ± 3.24 years old with a minimum of 5 years of competitive experience (7.05 ± 2.84 years and playing at the national or international level were evaluated. The Functional Test for Agility Performance is characterized as a specific open decision-making test where a tested player moves as quickly as possible in accordance to a pass made by another player. The time spent in the test was measured by two experienced coaches. Descriptive statistics, repeated measures analysis of variance (ANOVA, 95% limit of agreement (LOA, intraclass correlation coefficient (ICC and standard error of measurements (SEM were used for data analysis. Athletes completed the Functional Test for Agility Performance in 4.15 0.47 s. The ICC value was 0.87 (95% IC = 0.80-0.92. The SEM varied between 0.24 and 0.38 s. The LOA was 1.20 s and the CV average considering each individual trial was 6%. The Functional Test for Agility Performance was shown to be a reliable quick decision-making test for skilled water polo players.

  12. We need more replication research - A case for test-retest reliability.

    Science.gov (United States)

    Leppink, Jimmie; Pérez-Fuster, Patricia

    2017-06-01

    Following debates in psychology on the importance of replication research, we have also started to see pleas for a more prominent role for replication research in medical education. To enable replication research, it is of paramount importance to carefully study the reliability of the instruments we use. Cronbach's alpha has been the most widely used estimator of reliability in the field of medical education, notably as some kind of quality label of test or questionnaire scores based on multiple items or of the reliability of assessment across exam stations. However, as this narrative review outlines, Cronbach's alpha or alternative reliability statistics may complement but not replace psychometric methods such as factor analysis. Moreover, multiple-item measurements should be preferred above single-item measurements, and when using single-item measurements, coefficients as Cronbach's alpha should not be interpreted as indicators of the reliability of a single item when that item is administered after fundamentally different activities, such as learning tasks that differ in content. Finally, if we want to follow up on recent pleas for more replication research, we have to start studying the test-retest reliability of the instruments we use.

  13. Full length prototype SSC dipole test results

    International Nuclear Information System (INIS)

    Strait, J.; Brown, B.C.; Carson, J.

    1987-01-01

    Results are presented from tests of the first full length prototype SSC dipole magnet. The cryogenic behavior of the magnet during a slow cooldown to 4.5K and a slow warmup to room temperature has been measured. Magnetic field quality was measured at currents up to 2000 A. Averaged over the body field all harmonics with the exception of b 2 and b 8 are at or within the tolerances specified by the SSC Central Design Group. (The values of b 2 and b 8 result from known design and construction defects which will be be corrected in later magnets.) Using an NMR probe the average body field strength is measured to be 10.283 G/A with point to point variations on the order of one part in 1000. Data are presented on quench behavior of the magnet up to 3500 A (approximately 55% of full field) including longitudinal and transverse velocities for the first 250 msec of the quench

  14. Reliability of the Handgrip Strength Test in Elderly Subjects With Parkinson Disease.

    Science.gov (United States)

    Villafañe, Jorge H; Valdes, Kristin; Buraschi, Riccardo; Martinelli, Marco; Bissolotti, Luciano; Negrini, Stefano

    2016-03-01

    The handgrip strength test is widely used by clinicians; however, little has been investigated about its reliability when used in subjects with Parkinson disease (PD). The purpose of this study was to investigate the test-retest reliability of the handgrip strength test for subjects with PD. The PD group consisted of 15 patients, and the control group consisted of 15 healthy subjects. Each patient performed 3 pain-free maximal isometric contractions on each hand on 2 occasions, 1 week apart. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and 95% limits of agreement (LOA) were calculated. The 2-way analysis of variance (ANOVA) was conducted to determine the differences between sides and groups. Test-retest reliability of measurements of grip strength was excellent for dominant (ICC = 0.97; P = .001) and non-dominant (ICC = 0.98; P = .001) hand of participant with PD and (ICC = 0.99; P = .001) and (ICC = 0.99; P = .001) respectively, of healthy group. The Jamar hand dynamometer had fair to excellent test-retest reliability to test grip strength in participants with PD.

  15. An Operators View of Reliability Testing and Decay Heat Rejection Systems

    International Nuclear Information System (INIS)

    Henderson, J