WorldWideScience

Sample records for reliability program standard

  1. Reliability-based maintenance evaluations and standard preventive maintenance programs

    International Nuclear Information System (INIS)

    Varno, M.; McKinley, M.

    1993-01-01

    Due to recent issuance of 10CFR50.65, the U.S. Nuclear Regulatory Commission maintenance rule (Rule), and the open-quotes Industry Guideline for Monitoring the Effectiveness of Maintenance at Nuclear Power Plantsclose quotes prepared by the Nuclear Management and Resources Council, many utilities are undertaking review or evaluation of current preventive maintenance (PM) programs. Although PM optimization and documentation are not specifically required by the Rule, an appropriate and effective PM program (PMP) will be the cornerstone of the successful and cost-effective implementation of the Rule. Currently, a project is being conducted at the Vermont Yankee Nuclear Power Station (VYNPS) in conjunction with Quadrex Energy Services to evaluate, optimize, and document the PMP. The project began in March 1993 and is scheduled for completion in mid-1995. The initial scope for the project is the evaluation of those structures, systems, and components that are within the scope of the Rule. Because of the number of systems to be evaluated (∼50), the desired completion schedule, and cost considerations, a streamlined approach to PM optimization and documentation is being utilized

  2. Reliability programs for nuclear power plants. Regulatory standard S-98 revision 1

    International Nuclear Information System (INIS)

    2005-07-01

    The purpose of this regulatory standard is to help assure, in accordance with the purpose of the Nuclear Safety and Control Act (NSCA), that a licensee who constructs or operates a nuclear power plant (NPP) develops and implements a reliability program that assures that the systems important to safety at the plant can and will meet their defined design and performance specifications at acceptable levels of reliability throughout the lifetime of the facility. This regulatory standard describes the requirements of a reliability program for a nuclear power plant. The licensee shall implement the requirements described in this regulatory standard when a condition of a licence or other legally enforceable instrument so requires.(author)

  3. Human Reliability Program Overview

    Energy Technology Data Exchange (ETDEWEB)

    Bodin, Michael

    2012-09-25

    This presentation covers the high points of the Human Reliability Program, including certification/decertification, critical positions, due process, organizational structure, program components, personnel security, an overview of the US DOE reliability program, retirees and academia, and security program integration.

  4. Standard Hardware Acquisition and Reliability Program's (SHARP's) efforts in incorporating fiber optic interconnects into standard electronic module (SEM) connectors

    Science.gov (United States)

    Riggs, William R.

    1994-05-01

    SHARP is a Navy wide logistics technology development effort aimed at reducing the acquisition costs, support costs, and risks of military electronic weapon systems while increasing the performance capability, reliability, maintainability, and readiness of these systems. Lower life cycle costs for electronic hardware are achieved through technology transition, standardization, and reliability enhancement to improve system affordability and availability as well as enhancing fleet modernization. Advanced technology is transferred into the fleet through hardware specifications for weapon system building blocks of standard electronic modules, standard power systems, and standard electronic systems. The product lines are all defined with respect to their size, weight, I/O, environmental performance, and operational performance. This method of defining the standard is very conducive to inserting new technologies into systems using the standard hardware. This is the approach taken thus far in inserting photonic technologies into SHARP hardware. All of the efforts have been related to module packaging; i.e. interconnects, component packaging, and module developments. Fiber optic interconnects are discussed in this paper.

  5. Human factor reliability program

    International Nuclear Information System (INIS)

    Knoblochova, L.

    2017-01-01

    The human factor's reliability program was at Slovenske elektrarne, a.s. (SE) nuclear power plants. introduced as one of the components Initiatives of Excellent Performance in 2011. The initiative's goal was to increase the reliability of both people and facilities, in response to 3 major areas of improvement - Need for improvement of the results, Troubleshooting support, Supporting the achievement of the company's goals. The human agent's reliability program is in practice included: - Tools to prevent human error; - Managerial observation and coaching; - Human factor analysis; -Quick information about the event with a human agent; -Human reliability timeline and performance indicators; - Basic, periodic and extraordinary training in human factor reliability(authors)

  6. 18 CFR 39.5 - Reliability Standards.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Reliability Standards... RELIABILITY STANDARDS § 39.5 Reliability Standards. (a) The Electric Reliability Organization shall file each Reliability Standard or modification to a Reliability Standard that it proposes to be made effective under...

  7. Human Reliability Program Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Landers, John; Rogers, Erin; Gerke, Gretchen

    2014-05-18

    A Human Reliability Program (HRP) is designed to protect national security as well as worker and public safety by continuously evaluating the reliability of those who have access to sensitive materials, facilities, and programs. Some elements of a site HRP include systematic (1) supervisory reviews, (2) medical and psychological assessments, (3) management evaluations, (4) personnel security reviews, and (4) training of HRP staff and critical positions. Over the years of implementing an HRP, the Department of Energy (DOE) has faced various challenges and overcome obstacles. During this 4-day activity, participants will examine programs that mitigate threats to nuclear security and the insider threat to include HRP, Nuclear Security Culture (NSC) Enhancement, and Employee Assistance Programs. The focus will be to develop an understanding of the need for a systematic HRP and to discuss challenges and best practices associated with mitigating the insider threat.

  8. 78 FR 63036 - Transmission Planning Reliability Standards

    Science.gov (United States)

    2013-10-23

    ... Reliability Standards for the Bulk Power System, 130 FERC ] 61,200 (2010). \\8\\ Mandatory Reliability Standards... electric system operations across normal and contingency conditions. We also find that Reliability Standard... Reliability Standards for the Bulk Power System, 131 FERC ] 61,231 at P 21. Comments 24. NERC supports the...

  9. AECL's reliability and maintainability program

    International Nuclear Information System (INIS)

    Wolfe, W.A.; Nieuwhof, G.W.E.

    1976-05-01

    AECL's reliability and maintainability program for nuclear generating stations is described. How the various resources of the company are organized to design and construct stations that operate reliably and safely is shown. Reliability and maintainability includes not only special mathematically oriented techniques, but also the technical skills and organizational abilities of the company. (author)

  10. 77 FR 26714 - Transmission Planning Reliability Standards

    Science.gov (United States)

    2012-05-07

    ... Reliability Standards for the Bulk-Power System, Order No. 693, FERC Stats. & Regs. ] 31,242, order on reh'g... Standards for the Bulk Power System, 130 FERC ] 61,200 (2010) (March 2010 Order). \\12\\ Mandatory Reliability... excluded from future planning assessments and its potential impact to bulk electric system reliability...

  11. 76 FR 16277 - System Restoration Reliability Standards

    Science.gov (United States)

    2011-03-23

    ... electric system. Blackstart units are essential to restart generation and restore power to the grid in the... Standard EOP-007-0. \\2\\ Mandatory Reliability Standards for the Bulk-Power System, Order No. 693, 72 FR... = $5,894,624. Title: Mandatory Reliability Standards for the Bulk-Power System. Action: FERC 725A...

  12. Dental Assisting Program Standards.

    Science.gov (United States)

    Georgia Univ., Athens. Dept. of Vocational Education.

    This publication contains statewide standards for the dental assisting program in Georgia. The standards are divided into 12 categories: foundations (philosophy, purpose, goals, program objectives, availability, evaluation); admissions (admission requirements, provisional admission requirements, recruitment, evaluation and planning); program…

  13. 75 FR 71625 - System Restoration Reliability Standards

    Science.gov (United States)

    2010-11-24

    ... to start operating and delivering electric power without assistance from the electric system... and system restoration and reporting following disturbances. \\3\\ North American Electric Reliability... Reliability Standards for the Bulk-Power System and determined that the proposed requirements are necessary to...

  14. Emergency diesel generator reliability program

    International Nuclear Information System (INIS)

    Serkiz, A.W.

    1989-01-01

    The need for an emergency diesel generator (EDG) reliability program has been established by 10 CFR Part 50, Section 50.63, Loss of All Alternating Current Power, which requires that utilities assess their station blackout duration and recovery capability. EDGs are the principal emergency ac power sources for coping with a station blackout. Regulatory Guide 1.155, Station Blackout, identifies a need for (1) an EDG reliability equal to or greater than 0.95, and (2) an EDG reliability program to monitor and maintain the required levels. The resolution of Generic Safety Issue (GSI) B-56 embodies the identification of a suitable EDG reliability program structure, revision of pertinent regulatory guides and Tech Specs, and development of an Inspection Module. Resolution of B-56 is coupled to the resolution of Unresolved Safety Issue (USI) A-44, Station Blackout, which resulted in the station blackout rule, 10 CFR 50.63 and Regulatory Guide 1.155, Station Blackout. This paper discusses the principal elements of an EDG reliability program developed for resolving GSI B-56 and related matters

  15. 78 FR 41339 - Electric Reliability Organization Proposal To Retire Requirements in Reliability Standards

    Science.gov (United States)

    2013-07-10

    ...] Electric Reliability Organization Proposal To Retire Requirements in Reliability Standards AGENCY: Federal... Reliability Standards identified by the North American Electric Reliability Corporation (NERC), the Commission-certified Electric Reliability Organization. FOR FURTHER INFORMATION CONTACT: Kevin Ryan (Legal Information...

  16. Standards in reliability and safety engineering

    International Nuclear Information System (INIS)

    O'Connor, Patrick

    1998-01-01

    This article explains how the highest 'world class' levels of reliability and safety are achieved, by adherence to the basic principles of excellence in design, production, support and maintenance, by continuous improvement, and by understanding that excellence and improvement lead to reduced costs. These principles are contrasted with the methods that have been developed and standardised, particularly military standards for reliability, ISO9000, and safety case regulations. The article concludes that the formal, standardised approaches are misleading and counterproductive, and recommends that they be replaced by a philosophy based on the realities of human performance

  17. Standardizing the practice of human reliability analysis

    International Nuclear Information System (INIS)

    Hallbert, B.P.

    1993-01-01

    The practice of human reliability analysis (HRA) within the nuclear industry varies greatly in terms of posited mechanisms that shape human performance, methods of characterizing and analytically modeling human behavior, and the techniques that are employed to estimate the frequency with which human error occurs. This variation has been a source of contention among HRA practitioners regarding the validity of results obtained from different HRA methods. It has also resulted in attempts to develop standard methods and procedures for conducting HRAs. For many of the same reasons, the practice of HRA has not been standardized or has been standardized only to the extent that individual analysts have developed heuristics and consistent approaches in their practice of HRA. From the standpoint of consumers and regulators, this has resulted in a lack of clear acceptance criteria for the assumptions, modeling, and quantification of human errors in probabilistic risk assessments

  18. Interim reliability evaluation program (IREP)

    International Nuclear Information System (INIS)

    Carlson, D.D.; Murphy, J.A.

    1981-01-01

    The Interim Reliability Evaluation Program (IREP), sponsored by the Office of Nuclear Regulatory Research of the US Nuclear Regulatory Commission, is currently applying probabilistic risk analysis techniques to two PWR and two BWR type power plants. Emphasis was placed on the systems analysis portion of the risk assessment, as opposed to accident phenomenology or consequence analysis, since the identification of risk significant plant features was of primary interest. Traditional event tree/fault tree modeling was used for the analysis. However, the study involved a more thorough investigation of transient initiators and of support system faults than studies in the past and substantially improved techniques were used to quantify accident sequence frequencies. This study also attempted to quantify the potential for operator recovery actions in the course of each significant accident

  19. 76 FR 58101 - Electric Reliability Organization Interpretation of Transmission Operations Reliability Standard

    Science.gov (United States)

    2011-09-20

    ....C. Cir. 2009). \\4\\ Mandatory Reliability Standards for the Bulk-Power System, Order No. 693, FERC... for maintaining real and reactive power balance. \\14\\ Electric Reliability Organization Interpretation...; Order No. 753] Electric Reliability Organization Interpretation of Transmission Operations Reliability...

  20. 18 CFR 40.3 - Availability of Reliability Standards.

    Science.gov (United States)

    2010-04-01

    ... Reliability Standards. 40.3 Section 40.3 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT MANDATORY RELIABILITY STANDARDS FOR THE BULK-POWER SYSTEM § 40.3 Availability of Reliability Standards. The Electric Reliability...

  1. Behavioral reliability program for the nuclear industry. Technical report

    International Nuclear Information System (INIS)

    Buchanan, J.C.; Davis, S.O.; Dunnette, M.D.; Meyer, P.; Sharac, J.

    1981-07-01

    The subject of the study was the development of standards for a behavioral observation program which could be used by the NRC licensed nuclear industry to detect indications of emotional instability in its employees who have access to protected and vital areas. Emphasis was placed on those observable characteristics which could be assessed by supervisors or peers in a work environment. The behavioral reliability program, as was defined in this report, encompasses the concept and basic components of the program, the definition of the behavioral reliability program, the definition of the behavioral reliability criterion, and a set of instructions for the creation and implementation of the program by an individual facility

  2. Common-Reliability Cumulative-Binomial Program

    Science.gov (United States)

    Scheuer, Ernest, M.; Bowerman, Paul N.

    1989-01-01

    Cumulative-binomial computer program, CROSSER, one of set of three programs, calculates cumulative binomial probability distributions for arbitrary inputs. CROSSER, CUMBIN (NPO-17555), and NEWTONP (NPO-17556), used independently of one another. Point of equality between reliability of system and common reliability of components found. Used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. Program written in C.

  3. 78 FR 27113 - Version 5 Critical Infrastructure Protection Reliability Standards

    Science.gov (United States)

    2013-05-09

    ... approve certain reliability standards proposed by the North American Electric Reliability Corporation... Infrastructure Protection Reliability Standards, 143 FERC ] 61,055 (2013). This errata notice serves to correct P... Commission 18 CFR Part 40 [Docket No. RM13-5-000] Version 5 Critical Infrastructure Protection Reliability...

  4. 75 FR 14386 - Interpretation of Transmission Planning Reliability Standard

    Science.gov (United States)

    2010-03-25

    ...] Interpretation of Transmission Planning Reliability Standard March 18, 2010. AGENCY: Federal Energy Regulatory... transmission planning Reliability Standard TPL-002-0 provides that planning authorities and transmission... Reliability Standard TPL-002-0. In this order, the Commission proposes to reject NERC's proposed...

  5. 78 FR 76986 - Version 5 Critical Infrastructure Protection Reliability Standards

    Science.gov (United States)

    2013-12-20

    ...; Order No. 791] Version 5 Critical Infrastructure Protection Reliability Standards AGENCY: Federal Energy... 72755). The regulations approved certain reliability standards proposed by the North American Electric... Infrastructure Protection Reliability Standards, 145 FERC ] 61,160 (2013). This errata notice serves to correct P...

  6. 78 FR 58492 - Generator Verification Reliability Standards

    Science.gov (United States)

    2013-09-24

    ... power capability that is available for planning models and bulk electric system reliability assessments... of generator equipment needed to support Bulk-Power System reliability and enhance coordination of... support Bulk-Power System reliability and will ensure that accurate data is verified and made available...

  7. System-Reliability Cumulative-Binomial Program

    Science.gov (United States)

    Scheuer, Ernest M.; Bowerman, Paul N.

    1989-01-01

    Cumulative-binomial computer program, NEWTONP, one of set of three programs, calculates cumulative binomial probability distributions for arbitrary inputs. NEWTONP, CUMBIN (NPO-17555), and CROSSER (NPO-17557), used independently of one another. Program finds probability required to yield given system reliability. Used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. Program written in C.

  8. A reliability program approach to operational safety

    International Nuclear Information System (INIS)

    Mueller, C.J.; Bezella, W.A.

    1985-01-01

    A Reliability Program (RP) model based on proven reliability techniques is being formulated for potential application in the nuclear power industry. Methods employed under NASA and military direction, commercial airline and related FAA programs were surveyed and a review of current nuclear risk-dominant issues conducted. The need for a reliability approach to address dependent system failures, operating and emergency procedures and human performance, and develop a plant-specific performance data base for safety decision making is demonstrated. Current research has concentrated on developing a Reliability Program approach for the operating phase of a nuclear plant's lifecycle. The approach incorporates performance monitoring and evaluation activities with dedicated tasks that integrate these activities with operation, surveillance, and maintenance of the plant. The detection, root-cause evaluation and before-the-fact correction of incipient or actual systems failures as a mechanism for maintaining plant safety is a major objective of the Reliability Program. (orig./HP)

  9. 18 CFR 40.2 - Mandatory Reliability Standards.

    Science.gov (United States)

    2010-04-01

    ...-POWER SYSTEM § 40.2 Mandatory Reliability Standards. (a) Each applicable user, owner or operator of the Bulk-Power System must comply with Commission-approved Reliability Standards developed by the Electric... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Mandatory Reliability...

  10. 18 CFR 39.7 - Enforcement of Reliability Standards.

    Science.gov (United States)

    2010-04-01

    ... audits of compliance with Reliability Standards by users, owners and operators of the Bulk-Power System... resolved by an admission that the user, owner or operator of the Bulk-Power System violated a Reliability...-Power System for a violation of a Reliability Standard approved by the Commission if, after notice and...

  11. 78 FR 44475 - Protection System Maintenance Reliability Standard

    Science.gov (United States)

    2013-07-24

    ... that the performance or product has some reliability-related value, then the requirement will have...] Protection System Maintenance Reliability Standard AGENCY: Federal Energy Regulatory Commission, Energy... Commission proposes to approve a revised Reliability Standard, PRC-005- 2--Protection System Maintenance, to...

  12. Improvement of standards on functional reliability of electric power systems

    International Nuclear Information System (INIS)

    Barinov, V.A.; Volkov, G.A.; Kalita, V.V.; Kogan, F.L.; Makarov, S.F.; Manevich, A.S.; Mogirev, V.V.; Sin'chugov, F.I.; Skopintsev, V.A.; Khvoshchinskaya, Z.G.

    1993-01-01

    Analysis of the most principal aspects of the existing standards and requirements on assuring safety and stability of electric power systems (EPS) and effective (reliable and economical) power supply of consumers is given. The reliability is determined as ability to accomplish the assigned functions. Basic recommendations on improving the standards regulating the safety and reliability of the NPP functioning are formulated

  13. Equipment Reliability Program in NPP Krsko

    International Nuclear Information System (INIS)

    Skaler, F.; Djetelic, N.

    2006-01-01

    Operation that is safe, reliable, effective and acceptable to public is the common message in a mission statement of commercial nuclear power plants (NPPs). To fulfill these goals, nuclear industry, among other areas, has to focus on: 1 Human Performance (HU) and 2 Equipment Reliability (EQ). The performance objective of HU is as follows: The behaviors of all personnel result in safe and reliable station operation. While unwanted human behaviors in operations mostly result directly in the event, the behavior flaws either in the area of maintenance or engineering usually cause decreased equipment reliability. Unsatisfied Human performance leads even the best designed power plants into significant operating events, which can be found as well-known examples in nuclear industry. Equipment reliability is today recognized as the key to success. While the human performance at most NPPs has been improving since the start of WANO / INPO / IAEA evaluations, the open energy market has forced the nuclear plants to reduce production costs and operate more reliably and effectively. The balance between these two (opposite) goals has made equipment reliability even more important for safe, reliable and efficient production. Insisting on on-line operation by ignoring some principles of safety could nowadays in a well-developed safety culture and human performance environment exceed the cost of electricity losses. In last decade the leading USA nuclear companies put a lot of effort to improve equipment reliability primarily based on INPO Equipment Reliability Program AP-913 at their NPP stations. The Equipment Reliability Program is the key program not only for safe and reliable operation, but also for the Life Cycle Management and Aging Management on the way to the nuclear power plant life extension. The purpose of Equipment Reliability process is to identify, organize, integrate and coordinate equipment reliability activities (preventive and predictive maintenance, maintenance

  14. Software reliability and programming language

    International Nuclear Information System (INIS)

    Ehrenberger, W.

    1983-01-01

    When discussing advantages and drawbacks of programming languages, it is sometimes suggested to use these languages also for safety-related tasks. The author states the demands to be made on programming languages for this purpose. His recommendations are based on the work of TC7 of the European Workshop on Industrial Computer Systems and WG A3 of IEC SC 45a. (orig./HP) [de

  15. 18 CFR 292.308 - Standards for operating reliability.

    Science.gov (United States)

    2010-04-01

    ... reliability. 292.308 Section 292.308 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... SMALL POWER PRODUCTION AND COGENERATION Arrangements Between Electric Utilities and Qualifying... may establish reasonable standards to ensure system safety and reliability of interconnected...

  16. Establishing monitoring programs for travel time reliability.

    Science.gov (United States)

    2014-01-01

    Within the second Strategic Highway Research Program (SHRP 2), Project L02 focused on creating a suite of methods by which transportation agencies could monitor and evaluate travel time reliability. Creation of the methods also produced an improved u...

  17. 76 FR 66057 - North American Electric Reliability Corporation; Order Approving Regional Reliability Standard

    Science.gov (United States)

    2011-10-25

    ... Reliability Standard that is necessitated by a physical difference in the Bulk-Power System.\\7\\ \\7\\ Order No... Reliability Standards for the Bulk-Power System, Order No. 693, FERC Stats. & Regs. ] 31,242, order on reh'g... electric system event analyses and thereby improve system reliability by promoting improved system design...

  18. 76 FR 42534 - Mandatory Reliability Standards for Interconnection Reliability Operating Limits; System...

    Science.gov (United States)

    2011-07-19

    ... Reliability Operating Limits; System Restoration Reliability Standards AGENCY: Federal Energy Regulatory... data necessary to analyze and monitor Interconnection Reliability Operating Limits (IROL) within its... Interconnection Reliability Operating Limits, Order No. 748, 134 FERC ] 61,213 (2011). \\2\\ The term ``Wide-Area...

  19. The standard for program management

    CERN Document Server

    2017-01-01

    The Standard for Program Management – Fourth Edition differs from prior editions by focusing on the principles of good program management. Program activities have been realigned to program lifecycle phases rather than topics, and the first section was expanded to address the key roles of program manager, program sponsor and program management office. It has also been updated to better align with PMI’s Governance of Portfolios, Programs, and Projects: A Practice Guide.

  20. Reliability Standards of Complex Engineering Systems

    Science.gov (United States)

    Galperin, E. M.; Zayko, V. A.; Gorshkalev, P. A.

    2017-11-01

    Production and manufacture play an important role in today’s modern society. Industrial production is nowadays characterized by increased and complex communications between its parts. The problem of preventing accidents in a large industrial enterprise becomes especially relevant. In these circumstances, the reliability of enterprise functioning is of particular importance. Potential damage caused by an accident at such enterprise may lead to substantial material losses and, in some cases, can even cause a loss of human lives. That is why industrial enterprise functioning reliability is immensely important. In terms of their reliability, industrial facilities (objects) are divided into simple and complex. Simple objects are characterized by only two conditions: operable and non-operable. A complex object exists in more than two conditions. The main characteristic here is the stability of its operation. This paper develops the reliability indicator combining the set theory methodology and a state space method. Both are widely used to analyze dynamically developing probability processes. The research also introduces a set of reliability indicators for complex technical systems.

  1. A standard for test reliability in group research.

    Science.gov (United States)

    Ellis, Jules L

    2013-03-01

    Many authors adhere to the rule that test reliabilities should be at least .70 or .80 in group research. This article introduces a new standard according to which reliabilities can be evaluated. This standard is based on the costs or time of the experiment and of administering the test. For example, if test administration costs are 7 % of the total experimental costs, the efficient value of the reliability is .93. If the actual reliability of a test is equal to this efficient reliability, the test size maximizes the statistical power of the experiment, given the costs. As a standard in experimental research, it is proposed that the reliability of the dependent variable be close to the efficient reliability. Adhering to this standard will enhance the statistical power and reduce the costs of experiments.

  2. 78 FR 30804 - Transmission Planning Reliability Standards

    Science.gov (United States)

    2013-05-23

    ... shedding firm load versus planning to shed firm load, while still ensuring that the decision-making process... load loss. NERC states that it developed this information to ensure that an entity adequately... adverse reliability impacts. While consumers and local communities should be able to make decisions about...

  3. 75 FR 35689 - System Personnel Training Reliability Standards

    Science.gov (United States)

    2010-06-23

    ... planning staff at control areas and reliability coordinators concerning power system characteristics and... Coordination--Staffing). \\11\\ Mandatory Reliability Standards for the Bulk-Power System, Order No. 693, Federal... American bulk electric system are competent to perform those reliability-related tasks.\\22\\ The proposed...

  4. 78 FR 24107 - Version 5 Critical Infrastructure Protection Reliability Standards

    Science.gov (United States)

    2013-04-24

    ...-Power System.\\6\\ In Order No. 706, the Commission approved eight CIP Reliability Standards (CIP-002-1... documentation requirements to allow entities to focus on the reliability and security of the Bulk Power System... reliability of the bulk electric system. Requirement R1 includes controls to protect data that would be useful...

  5. 77 FR 7526 - Interpretation of Protection System Reliability Standard

    Science.gov (United States)

    2012-02-13

    ... Federal Power Act (FPA) requires a Commission-certified Electric Reliability Organization (ERO) to develop.... Cir. 2009). \\8\\ Mandatory Reliability Standards for the Bulk-Power System, Order No. 693, FERC Stats... a person that is ``directly and materially affected'' by Bulk-Power System reliability may request...

  6. 75 FR 72664 - System Personnel Training Reliability Standards

    Science.gov (United States)

    2010-11-26

    ...--Staffing). \\2\\ Mandatory Reliability Standards for the Bulk-Power System, Order No. 693, 72 FR 16416 (Apr... on the North American bulk electric system are competent to perform those reliability-related tasks... PER-004-2 will achieve a significant improvement in the reliability of the Bulk- Power System and...

  7. 76 FR 16240 - Mandatory Reliability Standards for Interconnection Reliability Operating Limits

    Science.gov (United States)

    2011-03-23

    ... identified by the Commission. \\5\\ Mandatory Reliability Standards for the Bulk-Power System, Order No. 693... reliability of the interconnection by ensuring that the bulk electric system is assessed during the operations... responsibility for SOLs. Further, Bulk-Power System reliability practices assign responsibilities for analyzing...

  8. Systems reliability analysis: applications of the SPARCS System-Reliability Assessment Computer Program

    International Nuclear Information System (INIS)

    Locks, M.O.

    1978-01-01

    SPARCS-2 (Simulation Program for Assessing the Reliabilities of Complex Systems, Version 2) is a PL/1 computer program for assessing (establishing interval estimates for) the reliability and the MTBF of a large and complex s-coherent system of any modular configuration. The system can consist of a complex logical assembly of independently failing attribute (binomial-Bernoulli) and time-to-failure (Poisson-exponential) components, without regard to their placement. Alternatively, it can be a configuration of independently failing modules, where each module has either or both attribute and time-to-failure components. SPARCS-2 also has an improved super modularity feature. Modules with minimal-cut unreliabiliy calculations can be mixed with those having minimal-path reliability calculations. All output has been standardized to system reliability or probability of success, regardless of the form in which the input data is presented, and whatever the configuration of modules or elements within modules

  9. Reliability and Validity of 10 Different Standard Setting Procedures.

    Science.gov (United States)

    Halpin, Glennelle; Halpin, Gerald

    Research indicating that different cut-off points result from the use of different standard-setting techniques leaves decision makers with a disturbing dilemma: Which standard-setting method is best? This investigation of the reliability and validity of 10 different standard-setting approaches was designed to provide information that might help…

  10. Conservation Law Enforcement Program Standardization

    National Research Council Canada - National Science Library

    Rogers, Stan

    2004-01-01

    The ultimate goal of standardization is to develop a safe and effective program that is recognized within the USAF, DoD, and by other Federal and state law enforcement agencies, and the general public...

  11. Improvement of AC motor reliability from technique standardization

    International Nuclear Information System (INIS)

    Muniz, P.R.; Faria, M.D.R.; Mendes, M.P.; Silva, J.N.; Dos Santos, J.D.

    2005-01-01

    The purpose of this paper is to explain the increase of reliability of motors serviced in the Electrical Maintenance Shop of Companhia Siderurgica de Tubarao by standardization of the technique based on Brazilian and International Standards, manufacturer's recommendations and the experience of the maintenance staff. (author)

  12. Reactive Programming in Standard ML

    OpenAIRE

    Pucella, Riccardo

    2004-01-01

    Reactive systems are systems that maintain an ongoing interaction with their environment, activated by receiving input events from the environment and producing output events in response. Modern programming languages designed to program such systems use a paradigm based on the notions of instants and activations. We describe a library for Standard ML that provides basic primitives for programming reactive systems. The library is a low-level system upon which more sophisticated reactive behavi...

  13. Observations on the Reliability of Rubidium Frequency Standards on Block 2/2A GPS Satellites

    Science.gov (United States)

    Dieter, Gary L.

    1996-01-01

    Currently, the block 2/2A Global Positioning System (GPS) satellites are equipped with two rubidium frequency standards. These frequency standards were originally intended to serve as the back-ups to two cesium frequency standards. As the constellation ages, the master Control Station is forced to initialize and increasing number or rubidium frequency standards. Unfortunately the operational use of these frequency standards has not lived up to initial expectations. Although the performance of these rubidium frequency standards has met and even exceeded GPS requirements, their reliability has not. The number of unscheduled outage times and the short operational lifetimes of the rubidium frequency standards compare poorly to the track record of the cesium frequency standards. Only a small number of rubidium frequency standards have actually been made operational. Of these, a large percentage have exhibited poor reliability. If this trend continues, it is unlikely that the rubidium frequency standards will help contribute to the navigation payload meeting program specification.

  14. Component reliability analysis for development of component reliability DB of Korean standard NPPs

    International Nuclear Information System (INIS)

    Choi, S. Y.; Han, S. H.; Kim, S. H.

    2002-01-01

    The reliability data of Korean NPP that reflects the plant specific characteristics is necessary for PSA and Risk Informed Application. We have performed a project to develop the component reliability DB and calculate the component reliability such as failure rate and unavailability. We have collected the component operation data and failure/repair data of Korean standard NPPs. We have analyzed failure data by developing a data analysis method which incorporates the domestic data situation. And then we have compared the reliability results with the generic data for the foreign NPPs

  15. Innovation and reliability of atomic standards for PTTI applications

    Science.gov (United States)

    Kern, R.

    1981-01-01

    Innovation and reliability in hyperfine frequency standards and clock systems are discussed. Hyperfine standards are defined as those precision frequency sources and clocks which use a hyperfine atomic transition for frequency control and which have realized significant commercial production and acceptance (cesium, hydrogen, and rubidium atoms). References to other systems such as thallium and ammonia are excluded since these atomic standards have not been commercially exploited in this country.

  16. Interim Reliability Evaluation Program procedures guide

    International Nuclear Information System (INIS)

    Carlson, D.D.; Gallup, D.R.; Kolaczkowski, A.M.; Kolb, G.J.; Stack, D.W.; Lofgren, E.; Horton, W.H.; Lobner, P.R.

    1983-01-01

    This document presents procedures for conducting analyses of a scope similar to those performed in Phase II of the Interim Reliability Evaluation Program (IREP). It documents the current state of the art in performing the plant systems analysis portion of a probabilistic risk assessment. Insights gained into managing such an analysis are discussed. Step-by-step procedures and methodological guidance constitute the major portion of the document. While not to be viewed as a cookbook, the procedures set forth the principal steps in performing an IREP analysis. Guidance for resolving the problems encountered in previous analyses is offered. Numerous examples and representative products from previous analyses clarify the discussion

  17. 78 FR 30747 - Reliability Standards for Geomagnetic Disturbances

    Science.gov (United States)

    2013-05-23

    ... that the scientific understanding of GMDs is still evolving, we recognize that Reliability Standards... by solar events, results in distortions to the earth's magnetic field, can be of varying intensity... systems.\\4\\ The interaction of the earth's magnetic field and solar events can cause low frequency GICs to...

  18. 76 FR 58716 - Interpretation of Transmission Planning Reliability Standard

    Science.gov (United States)

    2011-09-22

    ..., Western Public Agencies Group, Western Montana Electric G&T Cooperative, Inc., Oregon Municipal Electric... Enforcement of Electric Reliability Standards, Order No. 672, FERC Stats. & Regs. ] 31,204, order on reh'g... FERC ] 61,062, order on reh'g & compliance, 117 FERC ] 61,126 (2006), aff'd sub nom. Alcoa, Inc. v...

  19. 75 FR 81152 - Interpretation of Protection System Reliability Standard

    Science.gov (United States)

    2010-12-27

    ..., generation and transmission (G&T) cooperative or similar organization to accept compliance responsibility on... Reliability Standards, Order No. 672, FERC Stats. & Regs. ] 31,204, order on reh'g, Order No. 672-A, FERC... reh'g & compliance, 117 FERC ] 61,126 (2006), aff'd sub nom. Alcoa, Inc. v. FERC, 564 F.3d 1342 (DC...

  20. Human reliability program: Components and effects

    International Nuclear Information System (INIS)

    Baley-Downes, S.

    1986-01-01

    The term ''Human Reliability Program'' (HRP) is defined as a series of selective controls which are implemented and integrated to identify the ''insider threat'' from current and prospective employees who are dishonest, disloyal and unreliable. The HRP, although not a prediction of human behaviour, is an excellent tool for decision making and should compliment security and improve employee quality. The HRP consists of several component applications such as management evaluation; appropriate background investigative requirements; occupational health examination and laboratory testing; drug/alcohol screening; psychological testing and interviews; polygraph examination; job related aberrant behaviour recognition; on-going education and training; document control; drug/alcohol rehabilitation; periodic HRP audit; and implementation of an onsite central clearing house. The components and effects of HRP are discussed in further detail in this paper

  1. Standardization of reliability reporting for cochlear implants: an interim report.

    Science.gov (United States)

    Backous, Douglas D; Watson, Stacey D

    2007-04-01

    To propose a standard definition of "out of specification" for cochlear implants and a paradigm for inclusion of category C of the ISO standard 5841-2:2000 for reporting in cumulative survival statistics. A standard definition of "out of specification" and consistent reporting by manufacturers of cochlear implants will create a fair and consistent representation of cumulative survival. This will allow discernment of differences between manufacturers for reliability and for detection of trends in reliability between model types from the same manufacturer. Three separate meetings with representatives of the three manufacturers of cochlear implants marketed in the United States were staged over a 13-mo period. Standard questions, created by the authors, were addressed by each representative to determine the current state of device reliability reporting. Results were presented to clinicians at the William House Cochlear Implant study Group and the Implantable devices sub-committee of the American Academy of Otolaryngology (2004, 2005) and at the 8th International Cochlear Implant Conference (2004) for feedback. After assimilation of feedback by all parties, the standard was written and reviewed by representatives from each manufacturer for accuracy of data. A complaint-driven standard was developed. A "cochlear implant" as an internal device placed and skin closed in surgery. An internal device is "out of specification" when one or more technical characteristics is outside the limits of normal function and results in explantation or non-use by the patient." Children will be reported separately from adults, each model of device will be reported on annually, a minimum of 200 devices must be in each model group for Cumulative Survival Reporting (CSR). Confidence limits are set at 95%. Explants will be determined to be "biological" or "technical." Technical explants are included in CSR reports. Devices failing to meet specifications set by the manufacturer, not in use but

  2. 18 CFR 39.6 - Conflict of a Reliability Standard with a Commission Order.

    Science.gov (United States)

    2010-04-01

    ... Reliability Standard with a Commission Order. 39.6 Section 39.6 Conservation of Power and Water Resources..., APPROVAL, AND ENFORCEMENT OF ELECTRIC RELIABILITY STANDARDS § 39.6 Conflict of a Reliability Standard with... Transmission Organization determines that a Reliability Standard may conflict with a function, rule, order...

  3. Ontario's standard offer programs: moving toward a cleaner energy future

    International Nuclear Information System (INIS)

    Shervill, P.

    2006-01-01

    The Ontario Standard Offer Program is designed to ensure reliable, long-term electricity supply for Ontario. The functional areas of the program are planning, conservation and supply sector development. The long-term plan is to create a self-sustaining electricity market in Ontario with 2700 MW renewable sources by 2010 including wind, waterpower, solar photovoltaic (PV) and biomass

  4. Validity and Reliability of Baseline Testing in a Standardized Environment.

    Science.gov (United States)

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. 78 FR 44557 - Revision to Transmission Vegetation Management Reliability Standard; Notice of Compliance Filing

    Science.gov (United States)

    2013-07-24

    ... Transmission Vegetation Management Reliability Standard; Notice of Compliance Filing Take notice that on July 12, 2013, the North American Electric Reliability Corporation (NERC), pursuant to Order No. 777 \\1... Reliability Standard FAC-003-2 to its Web site. \\1\\ Revisions to Reliability Standard for Transmission...

  6. Program integration of predictive maintenance with reliability centered maintenance

    International Nuclear Information System (INIS)

    Strong, D.K. Jr; Wray, D.M.

    1990-01-01

    This paper addresses improving the safety and reliability of power plants in a cost-effective manner by integrating the recently developed reliability centered maintenance techniques with the traditional predictive maintenance techniques of nuclear power plants. The topics of the paper include a description of reliability centered maintenance (RCM), enhancing RCM with predictive maintenance, predictive maintenance programs, condition monitoring techniques, performance test techniques, the mid-Atlantic Reliability Centered Maintenance Users Group, test guides and the benefits of shared guide development

  7. Standards for Adult Education ESL Programs

    Science.gov (United States)

    TESOL Press, 2013

    2013-01-01

    What are the components of a quality education ESL program? TESOL's "Standards for Adult Education ESL Programs" answers this question by defining quality components from a national perspective. Using program indicators in eight distinct areas, the standards can be used to review an existing program or as a guide in setting up a new…

  8. Status of an operating reliability program

    International Nuclear Information System (INIS)

    Johnson, R.A.

    1985-01-01

    This paper deals with productivity improvement programs (PIP) for nuclear generating plants. The PIP was implemented in 1979 as a joint effort between Commonwealth Edison's (CECo's) operating nuclear stations and the Station Nuclear Engineering Department. Goals were set to reduce nonproductivity by 10% over a 5 year period. This goal was accomplished December 31, 1983. Topics of discussion are program method, problem analysis and resolution, program results, program improvements, and proposed additions to the PIP. The program is providing CECo with greater electrical generating productivity

  9. Selenide isotope generator for the Galileo mission. Reliability program plan

    International Nuclear Information System (INIS)

    1978-10-01

    The reliability program plan for the Selenide Isotope Generator (SIG) program is presented. It delineates the specific tasks that will be accomplished by Teledyne Energy Systems and its suppliers during design, development, fabrication and test of deliverable Radioisotopic Thermoelectric Generators (RTG), Electrical Heated Thermoelectric Generators (ETG) and associated Ground Support Equipment (GSE). The Plan is formulated in general accordance with procedures specified in DOE Reliability Engineering Program Requirements Publication No. SNS-2, dated June 17, 1974. The Reliability Program Plan presented herein defines the total reliability effort without further reference to Government Specifications. The reliability tasks to be accomplished are delineated herein and become the basis for contract compliance to the extent specified in the SIG contract Statement of Work

  10. 78 FR 44909 - Regional Reliability Standard BAL-002-WECC-2-Contingency Reserve

    Science.gov (United States)

    2013-07-25

    ...\\ Mandatory Reliability Standards for the Bulk-Power System, Order No. 693, FERC Stats. & Regs. ] 31,242...-002-WECC-2 (Contingency Reserve). The North American Electric Reliability Corporation (NERC) and... (Technical Information), Office of Electric Reliability, Division of Reliability Standards, Federal Energy...

  11. Standards for School Guidance Programs in Maryland.

    Science.gov (United States)

    Maryland State Dept. of Education, Baltimore. Div. of Compensatory, Urban, and Supplementary Programs.

    This brochure is a checklist to rate school compliance with the standards for school guidance programs in Maryland, which were developed by the Maryland State Department of Education. The first set of standards addresses the philosophy and goals of school guidance programs in Maryland and the extent to which program goals and objectives are…

  12. 76 FR 64082 - Mandatory Reliability Standards for the Bulk-Power System; Notice of Staff Meeting

    Science.gov (United States)

    2011-10-17

    ... Reliability Standards for the Bulk-Power System; Notice of Staff Meeting Take notice that the Federal Energy... R1.3.10 of Commission-approved transmission planning Reliability Standard TPL-002- 0 (System... additional actions necessary to address the matter.\\3\\ \\1\\ Mandatory Reliability Standards for the Bulk-Power...

  13. 78 FR 22773 - Revisions to Reliability Standard for Transmission Vegetation Management; Correction

    Science.gov (United States)

    2013-04-17

    ...; Order No. 777] Revisions to Reliability Standard for Transmission Vegetation Management; Correction... modifying certain Reliability Standards. DATES: Effective on May 28, 2013. FOR FURTHER INFORMATION CONTACT... Requirement R2 of Reliability Standard FAC-003-2 within 45 days of the effective date of the Final Rule, while...

  14. 78 FR 45447 - Revisions to Modeling, Data, and Analysis Reliability Standard

    Science.gov (United States)

    2013-07-29

    ...; Order No. 782] Revisions to Modeling, Data, and Analysis Reliability Standard AGENCY: Federal Energy... Analysis (MOD) Reliability Standard MOD- 028-2, submitted to the Commission for approval by the North... Organization. The Commission finds that the proposed Reliability Standard represents an improvement over the...

  15. 75 FR 52528 - Mandatory Reliability Standards for the Bulk-Power System; Notice of Technical Conference

    Science.gov (United States)

    2010-08-26

    ...] Mandatory Reliability Standards for the Bulk-Power System; Notice of Technical Conference August 19, 2010... Order No. 693 the Commission approved Reliability Standard BAL-003-0 as mandatory and enforceable and directed the ERO to develop a modification to BAL-003-0 through the Reliability Standards development...

  16. A survey of NASA and military standards on fault tolerance and reliability applied to robotics

    Science.gov (United States)

    Cavallaro, Joseph R.; Walker, Ian D.

    1994-01-01

    There is currently increasing interest and activity in the area of reliability and fault tolerance for robotics. This paper discusses the application of Standards in robot reliability, and surveys the literature of relevant existing standards. A bibliography of relevant Military and NASA standards for reliability and fault tolerance is included.

  17. 78 FR 21929 - Transmission Relay Loadability Reliability Standard; Notice of Compliance Filing

    Science.gov (United States)

    2013-04-12

    ... Relay Loadability Reliability Standard; Notice of Compliance Filing Take notice that on February 19... Relay Loadability Reliability Standard, Order No. 733, 130 FERC ] 61,221 (2010) (Order No. 733); order..., 136 FERC ] 61,185 (2011). \\2\\ Transmission Relay Loadability Reliability Standard, 138 FERC ] 61,197...

  18. 76 FR 23470 - Version One Regional Reliability Standard for Transmission Operations

    Science.gov (United States)

    2011-04-27

    ...; Order No. 752] Version One Regional Reliability Standard for Transmission Operations AGENCY: Federal... Power Act, the Federal Energy Regulatory Commission approves regional Reliability Standard TOP-007-WECC... purpose of this regional Reliability Standard is to ensure that actual flows and associated scheduled...

  19. 78 FR 55249 - Transmission Relay Loadability Reliability Standard; Notice of Compliance Filing

    Science.gov (United States)

    2013-09-10

    ...; RM11-16-000] Transmission Relay Loadability Reliability Standard; Notice of Compliance Filing Take.... \\1\\ Transmission Relay Loadability Reliability Standard, Order No. 733, 130 FERC ] 61, 221 (2010..., Order No. 733-B, 136 FERC ] 61,185 (2011). \\2\\ Transmission Relay Loadability Reliability Standard, 138...

  20. 76 FR 23801 - North American Electric Reliability Corporation; Order Approving Reliability Standard

    Science.gov (United States)

    2011-04-28

    ... have an operating plan and facilities for backup functionality to ensure Bulk-Power System reliability... entity's primary control center on the reliability of the Bulk-Power System. \\1\\ Mandatory Reliability... potential impact of a violation of the Requirement on the reliability of the Bulk-Power System. The...

  1. 78 FR 72755 - Version 5 Critical Infrastructure Protection Reliability Standards

    Science.gov (United States)

    2013-12-03

    ... impact on Bulk-Power System reliability. However, the Commission is concerned that the proposed language... focus on the reliability and security of the Bulk Power System.'' \\26\\ Accordingly, NERC requests that...-002-5 through CIP-011-1, submitted by the North American Electric Reliability Corporation (NERC), the...

  2. Establishing monitoring programs for travel time reliability. [supporting datasets

    Science.gov (United States)

    2014-01-01

    The objective of this project was to develop system designs for programs to monitor travel time reliability and to prepare a guidebook that practitioners and others can use to design, build, operate, and maintain such systems. Generally, such travel ...

  3. Management plan for the Nuclear Standards Program

    International Nuclear Information System (INIS)

    1979-11-01

    This Management Plan was prepared to describe the manner in which Oak Ridge National Laboratory will provide technical management of the Nuclear Standards Program. The organizational structure that has been established within ORNL for this function is the Nuclear Standards Management Center, which includes the Nuclear Standards Office (NSO) already in existence at ORNL. This plan is intended to support the policies and practices for the development and application of technical standards in ETN projects, programs, and technology developments as set forth in a standards policy memorandum from the DOE Program Director for Nuclear Energy

  4. Statis Program Analysis for Reliable, Trusted Apps

    Science.gov (United States)

    2017-02-01

    and prevent errors in their Java programs. The Checker Framework includes compiler plug-ins (“checkers”) that find bugs or verify their absence. It...versions of the Java language. 4.8 DATAFLOW FRAMEWORK The dataflow framework enables more accurate analysis of source code. (Despite their similar...names, the dataflow framework is independent of the (Information) Flow Checker of chapter 2.) In Java code, a given operation may be permitted or

  5. 78 FR 38851 - Electric Reliability Organization Proposal To Retire Requirements in Reliability Standards

    Science.gov (United States)

    2013-06-28

    ... either: Provide little protection for Bulk-Power System reliability or are redundant with other aspects... for retirement either: (1) Provide little protection for Bulk-Power System reliability or (2) are... to assure reliability of the Bulk-Power System and should be withdrawn. We have identified 41...

  6. Standards for maintenance documentation of COSMOS programs

    International Nuclear Information System (INIS)

    Burstall, R.F.; Rickets, T.M.; Butland, A.T.D.

    1982-06-01

    The Compatible Open Shop Modular Operating Scheme (COSMOS) is used for fast reactor neutronics and subassembly distortion calculations in the UK. It provides database and databank facilities for this purpose. A large number of applications programs use these facilities. This report sets down the standards agreed for use in the preparation of maintenance documents for these programs. These standards have been developed as the result of experience with earlier more complicated standards. Some of the terminology used in this report is particular to COSMOS, but the general features of the standard may be useful to those responsible for other computer programs. (author)

  7. 78 FR 73112 - Monitoring System Conditions-Transmission Operations Reliability Standards; Interconnection...

    Science.gov (United States)

    2013-12-05

    ...\\ \\8\\ Mandatory Reliability Standards for the Bulk-Power System, Order No. 693, 72 FR 16416 (Apr. 4... operators and reliability coordinators to ``plan and operate the interconnected Bulk Electric System in a... mandated in the currently- effective standards, thereby improving reliability of the bulk power system...

  8. 77 FR 64920 - Revisions to Reliability Standard for Transmission Vegetation Management

    Science.gov (United States)

    2012-10-24

    ... reliability of the Bulk Electric System.'' NERC defines ``System Operating Limit'' as ``[t]he value (such as... values or gives reason to revisit the Reliability Standard. Accordingly, consistent with the activity...] Revisions to Reliability Standard for Transmission Vegetation Management AGENCY: Federal Energy Regulatory...

  9. 75 FR 14103 - Version One Regional Reliability Standard for Resource and Demand Balancing

    Science.gov (United States)

    2010-03-24

    ... current regional Reliability Standard was developed and used under a manual interchange transaction...] Version One Regional Reliability Standard for Resource and Demand Balancing March 18, 2010. AGENCY... section 215 of the Federal Power Act, the Commission proposes to remand a revised regional Reliability...

  10. 77 FR 53884 - Automatic Underfrequency Load Shedding and Load Shedding Plans Reliability Standards; Notice of...

    Science.gov (United States)

    2012-09-04

    ... Underfrequency Load Shedding and Load Shedding Plans Reliability Standards; Notice of Compliance Filing Take notice that on August 9, 2012, North American Electric Reliability Corporation submitted a compliance... Load Shedding Plans Reliability Standards, 139 FERC ] 61,098, (Order No. 763) (2012). Any person...

  11. 75 FR 15371 - Time Error Correction Reliability Standard

    Science.gov (United States)

    2010-03-29

    ... Electric Reliability Council of Texas (ERCOT) manages the flow of electric power to 22 million Texas customers. As the independent system operator for the region, ERCOT schedules power on an electric grid that... Coordinating Council (WECC) is responsible for coordinating and promoting bulk electric system reliability in...

  12. John F. Kennedy Space Center, Safety, Reliability, Maintainability and Quality Assurance, Survey and Audit Program

    Science.gov (United States)

    1994-01-01

    This document is the product of the KSC Survey and Audit Working Group composed of civil service and contractor Safety, Reliability, and Quality Assurance (SR&QA) personnel. The program described herein provides standardized terminology, uniformity of survey and audit operations, and emphasizes process assessments rather than a program based solely on compliance. The program establishes minimum training requirements, adopts an auditor certification methodology, and includes survey and audit metrics for the audited organizations as well as the auditing organization.

  13. Automation of reliability evaluation procedures through CARE - The computer-aided reliability estimation program.

    Science.gov (United States)

    Mathur, F. P.

    1972-01-01

    Description of an on-line interactive computer program called CARE (Computer-Aided Reliability Estimation) which can model self-repair and fault-tolerant organizations and perform certain other functions. Essentially CARE consists of a repository of mathematical equations defining the various basic redundancy schemes. These equations, under program control, are then interrelated to generate the desired mathematical model to fit the architecture of the system under evaluation. The mathematical model is then supplied with ground instances of its variables and is then evaluated to generate values for the reliability-theoretic functions applied to the model.

  14. RCM [reliability-centered maintenance] at Ginna: Preventive maintenance program optimization at year 20

    International Nuclear Information System (INIS)

    Edgar, E.C.

    1989-01-01

    The reliability-centered maintenance (RCM) program at Rochester Gas ampersand Electric Company's Ginna station is entering its second year. Of the 20 systems originally selected for evaluation, 10 are in various stages of completion, and recommendations resulting from the earliest systems studied are now being implemented. As expected, few major discoveries have been made in terms of preventive maintenance program failings or excesses. The performance of the now 20-yr-old plant has been excellent in recent years, and objectives focus more on ensuring continued high standards of safety, reliability, and economy than on maintenance program cost reduction

  15. 78 FR 71448 - Regional Reliability Standard BAL-002-WECC-2-Contingency Reserve

    Science.gov (United States)

    2013-11-29

    ...; Order No. 789] Regional Reliability Standard BAL-002-WECC-2--Contingency Reserve AGENCY: Federal Energy... (Contingency Reserve). The North American Electric Reliability Corporation (NERC) and Western Electricity... Region and is meant to specify the quantity and types of [[Page 71449

  16. Reliability of the individual components of the Canadian Armed Forces Physical Employment Standard.

    Science.gov (United States)

    Stockbrugger, Barry G; Reilly, Tara J; Blacklock, Rachel E; Gagnon, Patrick J

    2018-01-29

    This investigation recruited 24 participants from both the Canadian Armed Forces (CAF) and civilian populations to complete 4 separate trials at "best effort" of each of the 4 components in the CAF Physical Employment Standard named the FORCE Evaluation: Fitness for Operational Requirements of CAF Employment. Analyses were performed to examine the level of variability and reliability within each component. The results demonstrate that candidates should be provided with at least 1 retest if they have recently completed at least 2 previous best effort attempts as per the protocol. In addition, the minimal detectable difference is given for each of the 4 components in seconds which identifies the threshold for subsequent action, either retest or remedial training, for those unable to meet the minimum standard. These results will educate the delivery of this employment standard, function as a method of accommodation, in addition to providing direction for physical training programs.

  17. 75 FR 66038 - Planning Resource Adequacy Assessment Reliability Standard

    Science.gov (United States)

    2010-10-27

    ..., providing a common framework for resource adequacy analysis, assessment, and documentation) effectively and...://www.nerc.com/commondocs.php?cd=2 . D. Proposed Effective Date 24. Proposed regional Reliability...

  18. 1994 DOE Technical Standards Program Workshop: Proceedings

    International Nuclear Information System (INIS)

    Spellman, D.J.

    1994-01-01

    The DOE Technical Standards Program has been structured to provide guidance and assistance for the development, adoption, and use of voluntary standards within the Department. OMB Circular A-119, ''Federal Participation in the Development and Use of Voluntary Standards'' establishes the policy to be followed in working with voluntary standards bodies, and in adopting and using voluntary standards whenever feasible. The DOE Technical Standards Program is consistent with this policy and is dedicated to the task of promoting its implementation. The theme of this year's workshop is ''Standards Initiatives in Environmental Management fostering the development and use of industry standards for safe, environmentally responsible operations.'' The objective of the workshop is to increase the participant's awareness of the standardization activities taking place nationally and internationally and the impact of these activities on their efforts, and to facilitate the exchange of experiences, processes, and tools for implementing the program. Workshop sessions will include presentations by industry and Government notables in the environment, safety, and health arena with ample opportunity for everyone to ask questions and share experiences. There will be a breakout session which will concentrate on resolution of issues arising from the implementation of the DOE Technical Standards Program and a plenary session to discuss the plans developed by the breakout groups. Many organizations provide services and products which support the development, processing, distribution, and retrieval of standards. Those organizations listed at the end of the agenda will have exhibits available for your perusal throughout the workshop. Last year's workshop was very successful in stimulating an understanding of an interest in the standards program. This year, we hope to build on that success and provide an environment for the synergism of ideas to enhance the program and advance its implementation

  19. Human performance for the success of equipment reliability programs

    International Nuclear Information System (INIS)

    Woodcock, J.

    2007-01-01

    Human performance is a critical element of programs directed at equipment reliability. Reliable equipment performance requires broad support from all levels of plant management and throughout all plant departments. Experience at both nuclear power plants and fuel manufacturing plants shows that human performance must be addressed during all phases of program implementation from the beginning through the establishment of a living, on-going process. At the beginning, certain organizational and management actions during the initiation of the program set the stage for successful adoption by station personnel, leading to more rapid benefits. For the long term, equipment reliability is a living process needed throughout the lifetime of a station, a program which must be motivated and measured. Sustained acceptance and participation by the plant personnel is a requirement, and culture is a key ingredient. This paper will provide an overview of key human performance issues to be considered, using the application of the INPO AP-913 Equipment Reliability Guideline as a basis and gives some best practices for training, communicating and implementing programs. The very last part includes ways to tell if the program is effective

  20. USL/DBMS NASA/PC R and D project C programming standards

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Moreau, Dennis R.

    1984-01-01

    A set of programming standards intended to promote reliability, readability, and portability of C programs written for PC research and development projects is established. These standards must be adhered to except where reasons for deviation are clearly identified and approved by the PC team. Any approved deviation from these standards must also be clearly documented in the pertinent source code.

  1. Reliability centered Maintenance (RCM) program for Chashma NPP (CHASNUPP)

    International Nuclear Information System (INIS)

    Khalid, S.; Khan, S.A.

    2000-01-01

    This paper describes the proposed Reliability Centered Maintenance (RCM) program for Chashma Nuclear Power Plant (CHASNUPP). Major steps are the identification of risk critical components and the implementation of RCM procedures. Identification of risk critical components is based upon the CHASNUPP level 1 PSA results (performed under IAEA TC Project PAK/9/019) which is near completion. The other requirements for implementation of RCM program is the qualitative analysis to be performed for identifying the dominant potential failure modes of each risk critical component and determination of the necessary maintenance activities, required to ensure reliable operation of the identified risk critical components. Implementation of RCM program for these components will lead to improvement in plant availability and safety together with reduction in the maintenance cost. Development - implementation of RCM program at this stage will help the CHASNUPP Maintenance department who is now developing the maintenance program - procedures for CHASNUPP. (author)

  2. 1996 DOE technical standards program workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    The workshop theme is `The Strategic Standardization Initiative - A Technology Exchange and Global Competitiveness Challenge for DOE.` The workshop goal is to inform the DOE technical standards community of strategic standardization activities taking place in the Department, other Government agencies, standards developing organizations, and industry. Individuals working on technical standards will be challenged to improve cooperation and communications with the involved organizations in response to the initiative. Workshop sessions include presentations by representatives from various Government agencies that focus on coordination among and participation of Government personnel in the voluntary standards process; reports by standards organizations, industry, and DOE representatives on current technology exchange programs; and how the road ahead appears for `information superhighway` standardization. Another session highlights successful standardization case studies selected from several sites across the DOE complex. The workshop concludes with a panel discussion on the goals and objectives of the DOE Technical Standards Program as envisioned by senior DOE management. The annual workshop on technical standards has proven to be an effective medium for communicating information related to standards throughout the DOE community. Technical standards are used to transfer technology and standardize work processes to produce consistent, acceptable results. They provide a practical solution to the Department`s challenge to protect the environment and the health and safety of the public and workers during all facility operations. Through standards, the technologies of industries and governments worldwide are available to DOE. The DOE Technical Standards Program, a Department-wide effort that crosscuts all organizations and disciplines, links the Department to those technologies.

  3. Design reliability assurance program for Korean next generation reactor

    International Nuclear Information System (INIS)

    Lee, Beom-Su; Han, Jin-Kyu; Na, Jang Hwan; Yoo, Kyung Yeong

    1997-01-01

    The Korean Next Generation Reactor (KNGR) project is to develop standardized nuclear power plant design for the construction of future nuclear power plants in Korea. The main purpose of the KNGR project is to develop the advanced nuclear power plants, which enhance safety and economics significantly through the incorporation of design concepts for severe accident prevention and mitigation, supplementary passive safety concept, simplification and application of modularization and so on. For those, Probabilistic Safety Assessment (PSA) and availability study will be performed at the early stage of the design, and the Design Reliability Assurance Program (D-RAP) is applied in the development of the KNGR to ensure that the safety and availability evaluated in the PSA and availability study at the early phase of the design is maintained through the detailed design, construction, procurement and operation of the plants. This paper presents the D-RAP concept that could be applied at the stage of the basic design of the nuclear power plants, based on the models for the reference plants and/or similar plants. 4 refs., 1 fig

  4. Value-Added Models for Teacher Preparation Programs: Validity and Reliability Threats, and a Manageable Alternative

    Science.gov (United States)

    Brady, Michael P.; Heiser, Lawrence A.; McCormick, Jazarae K.; Forgan, James

    2016-01-01

    High-stakes standardized student assessments are increasingly used in value-added evaluation models to connect teacher performance to P-12 student learning. These assessments are also being used to evaluate teacher preparation programs, despite validity and reliability threats. A more rational model linking student performance to candidates who…

  5. A reliability program for emergency diesel generators at nuclear power plants: Program structure

    International Nuclear Information System (INIS)

    Lofgren, E.V.; DeMoss, G.M.; Fragola, J.R.; Appignani, P.L.; Delarche, G.; Boccio, J.

    1988-04-01

    The purpose of this report is to provide technical guidelines for NRC staff use in the development of positions for evaluating emergency diesel generator (EDG) reliability programs. Such reviews will likely result following resolution of USI A-44 and GSI B-56. The diesel generator reliability program is a management system for achieving and maintaining a selected (or target) level of reliability. This can be achieved by: (1) understanding the factors that control the EDG reliability and (2) then applying reliability and maintenance techniques in the proper proportion to achieve selected performance goals. The concepts and guidelines discussed in this report are concepts and approaches that have been successful in applications where high levels of reliability must be maintained. Both an EDG reliability program process and a set of review items for NRC use are provided. The review items represent a checklist for reviewing EDG reliability programs. They do not, in themselves, constitute a reliability program. Rather, the review items are those distinctive features of a reliability program that must be present for the program to be effective

  6. 75 FR 71613 - Mandatory Reliability Standards for Interconnection Reliability Operating Limits

    Science.gov (United States)

    2010-11-24

    ... Interconnection to relieve overloads on the facilities modeled in the Interchange Distribution Calculator (IDC... for other SOLs. But the Functional Model assigns a much broader role to the reliability coordinator to...

  7. 77 FR 16435 - Transmission Relay Loadability Reliability Standard

    Science.gov (United States)

    2012-03-21

    ... conditions on all applicable transmission lines and transformers. I. Background A. Relay Protection Systems 2... and a power swing. If a power swing is detected, the protection system, ``blocks,'' or prevents the... to the reliability of the Bulk-Power System by requiring load-responsive phase protection relay...

  8. High Speed Simulation Framework for Reliable Logic Programs

    International Nuclear Information System (INIS)

    Lee, Wan-Bok; Kim, Seog-Ju

    2006-01-01

    This paper shows a case study of designing a PLC logic simulator that was developed to simulate and verify PLC control programs for nuclear plant systems. The nuclear control system requires strict restrictions rather than normal process control system does, since it works with nuclear power plants requiring high reliability under severe environment. One restriction is the safeness of the control programs which can be assured by exploiting severe testing. Another restriction is the simulation speed of the control programs, that should be fast enough to control multi devices concurrently in real-time. To cope with these restrictions, we devised a logic compiler which generates C-code programs from given PLC logic programs. Once the logic program was translated into C-code, the program could be analyzed by conventional software analysis tools and could be used to construct a fast logic simulator after cross-compiling, in fact, that is a kind of compiled-code simulation

  9. 75 FR 35021 - Reliability Standards Development and NERC and Regional Entity Enforcement; Notice of Technical...

    Science.gov (United States)

    2010-06-21

    ... Standards Development and NERC and Regional Entity Enforcement; Notice of Technical Conference June 15, 2010... Technical Conference to address industry perspectives on certain issues pertaining to the development and... Electric Reliability Organization's (ERO) standards development process; communication and interactions...

  10. Reliability assurance program for operational emergency ac power system

    International Nuclear Information System (INIS)

    Heineman, J.B.; Ragland, W.A.; Mueller, C.J.

    1985-01-01

    A comprehensive review of emergency ac power systems in nuclear generating plants (the vast majority of these plants contain redundant diesel generator systems) delineates several operational areas that can be improved by instituting a reliability assurance program (RAP), which initially upgrades the diesel generator performance and provides for ongoing monitoring and maintenance based upon alert levels

  11. 75 FR 36385 - Reliability Standards Development and NERC and Regional Entity Enforcement Supplemental Notice of...

    Science.gov (United States)

    2010-06-25

    ... Standards Development and NERC and Regional Entity Enforcement Supplemental Notice of Technical Conference... development and enforcement of mandatory Reliability Standards for the Bulk-Power System by the North American Electric Reliability Corporation and the Regional Entities. The conference will be held on Tuesday, July 6...

  12. 75 FR 40819 - Reliability Standards Development and NERC and Regional Entity Enforcement; Notice Soliciting...

    Science.gov (United States)

    2010-07-14

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. AD10-14-000] Reliability Standards Development and NERC and Regional Entity Enforcement; Notice Soliciting Comments July 7, 2010... technical conference to explore issues pertaining to the development of mandatory Reliability Standards for...

  13. Achieving High Reliability Operations Through Multi-Program Integration

    Energy Technology Data Exchange (ETDEWEB)

    Holly M. Ashley; Ronald K. Farris; Robert E. Richards

    2009-04-01

    Over the last 20 years the Idaho National Laboratory (INL) has adopted a number of operations and safety-related programs which has each periodically taken its turn in the limelight. As new programs have come along there has been natural competition for resources, focus and commitment. In the last few years, the INL has made real progress in integrating all these programs and are starting to realize important synergies. Contributing to this integration are both collaborative individuals and an emerging shared vision and goal of the INL fully maturing in its high reliability operations. This goal is so powerful because the concept of high reliability operations (and the resulting organizations) is a masterful amalgam and orchestrator of the best of all the participating programs (i.e. conduct of operations, behavior based safety, human performance, voluntary protection, quality assurance, and integrated safety management). This paper is a brief recounting of the lessons learned, thus far, at the INL in bringing previously competing programs into harmony under the goal (umbrella) of seeking to perform regularly as a high reliability organization. In addition to a brief diagram-illustrated historical review, the authors will share the INL’s primary successes (things already effectively stopped or started) and the gaps yet to be bridged.

  14. RIO: a program to determine reliability importance and allocate optimal reliability goals

    International Nuclear Information System (INIS)

    Poloski, J.P.

    1978-09-01

    The designer of a nuclear plant must know the plant's associated risk limitations so that he can design the plant accordingly. To design a safety system, he must understand its importance and how it relates to the overall plant risk. The computer program RIO can aid the designer to understand a system's contribution to the plant's overall risk. The methodology developed and presented was sponsored by the Nuclear Research Applications Division of the Department of Energy for use in the Gas Cooled Fast Breeder Reactor (GCFR) Program. The principal motivation behind its development was the need to translate nuclear plants safety goals into reliability goals for systems which make up that plant. The method described herein will make use of the GCFR Accident Initiation and Progression Analyses (AIPA) event trees and other models in order to determine these reliability goals

  15. DOE Human Reliability Program Removals Report 2004-2006

    International Nuclear Information System (INIS)

    Center for Human Reliability Studies

    2007-01-01

    This report presents results of the comprehensive data analysis and assessment of all U.S. Department of Energy (DOE) and National Nuclear Security Administration (NNSA) facilities that have positions requiring workers to be certified in the Human Reliability Program (HRP). Those facilities include: Albuquerque, Amarillo, DOE Headquarters, Hanford, Idaho, Nevada, Oak Ridge, Oakland, and Savannah River. The HRP was established to ensure, through continuous review and evaluation, the reliability of individuals who have access to the DOE's most sensitive facilities, materials, and information

  16. Critical Assessment of the Foundations of Power Transmission and Distribution Reliability Metrics and Standards.

    Science.gov (United States)

    Nateghi, Roshanak; Guikema, Seth D; Wu, Yue Grace; Bruss, C Bayan

    2016-01-01

    The U.S. federal government regulates the reliability of bulk power systems, while the reliability of power distribution systems is regulated at a state level. In this article, we review the history of regulating electric service reliability and study the existing reliability metrics, indices, and standards for power transmission and distribution networks. We assess the foundations of the reliability standards and metrics, discuss how they are applied to outages caused by large exogenous disturbances such as natural disasters, and investigate whether the standards adequately internalize the impacts of these events. Our reflections shed light on how existing standards conceptualize reliability, question the basis for treating large-scale hazard-induced outages differently from normal daily outages, and discuss whether this conceptualization maps well onto customer expectations. We show that the risk indices for transmission systems used in regulating power system reliability do not adequately capture the risks that transmission systems are prone to, particularly when it comes to low-probability high-impact events. We also point out several shortcomings associated with the way in which regulators require utilities to calculate and report distribution system reliability indices. We offer several recommendations for improving the conceptualization of reliability metrics and standards. We conclude that while the approaches taken in reliability standards have made considerable advances in enhancing the reliability of power systems and may be logical from a utility perspective during normal operation, existing standards do not provide a sufficient incentive structure for the utilities to adequately ensure high levels of reliability for end-users, particularly during large-scale events. © 2015 Society for Risk Analysis.

  17. 76 FR 58730 - Version 4 Critical Infrastructure Protection Reliability Standards

    Science.gov (United States)

    2011-09-22

    ... Critical Cyber Assets; (3) internal, management, approval of the risk-based assessment; (4) external review... consider applicable features of the NIST Risk Management Framework to ensure protection of all cyber... activities in the Risk Management Framework has an associated NIST security standard and/or guidance document...

  18. Department of Energy Nuclear Energy Standards Program

    International Nuclear Information System (INIS)

    Silver, E.G.

    1980-01-01

    The policy with respect to the development and use of standards in the Department of Energy (DOE) programs concerned with maintaining and developing the nuclear option for the civilian sector (both in the form of the currently used light water reactors and for advanced concepts including the Liquid Metal Fast Breeder Reactor), is embodied in a Nuclear Standards Policy, issued in 1978, whose perspectives and philosophy are discussed

  19. Environmental radioactive intercomparison program and radioactive standards program

    Energy Technology Data Exchange (ETDEWEB)

    Dilbeck, G. [Environmental Monitoring Systems Laboratory, Las Vegas, NV (United States)

    1993-12-31

    The Environmental Radioactivity Intercomparison Program described herein provides quality assurance support for laboratories involved in analyzing public drinking water under the Safe Drinking Water Act (SDWA) Regulations, and to the environmental radiation monitoring activities of various agencies. More than 300 federal and state nuclear facilities and private laboratories participate in some phase of the program. This presentation describes the Intercomparison Program studies and matrices involved, summarizes the precision and accuracy requirements of various radioactive analytes, and describes the traceability determinations involved with radioactive calibration standards distributed to the participants. A summary of program participants, sample and report distributions, and additional responsibilities of this program are discussed.

  20. System safety and reliability using object-oriented programming techniques

    International Nuclear Information System (INIS)

    Patterson-Hine, F.A.; Koen, B.V.

    1987-01-01

    Direct evaluation fault tree codes have been written in recursive, list-processing computer languages such as PL/1 (PATREC-I) and LISP (PATREC-L). The pattern-matching strategy implemented in these codes has been used extensively in France to evaluate system reliability. Recent reviews of the risk management process suggest that a data base containing plant-specific information be integrated with a package of codes used for probabilistic risk assessment (PRA) to alleviate some of the difficulties that make a PRA so costly and time-intensive. A new programming paradigm, object-oriented programming, is uniquely suited for the development of such a software system. A knowledge base and fault tree evaluation algorithm, based on previous experience with PATREC-L, have been implemented using object-oriented techniques, resulting in a reliability assessment environment that is easy to develop, modify, and extend

  1. Interim reliability evaluation program, Browns Ferry fault trees

    International Nuclear Information System (INIS)

    Stewart, M.E.

    1981-01-01

    An abbreviated fault tree method is used to evaluate and model Browns Ferry systems in the Interim Reliability Evaluation programs, simplifying the recording and displaying of events, yet maintaining the system of identifying faults. The level of investigation is not changed. The analytical thought process inherent in the conventional method is not compromised. But the abbreviated method takes less time, and the fault modes are much more visible

  2. Validity and Reliability of a Glucometer Against Industry Reference Standards.

    Science.gov (United States)

    Salacinski, Amanda J; Alford, Micah; Drevets, Kathryn; Hart, Sarah; Hunt, Brian E

    2014-01-01

    As an appealing alternative to reference glucose analyzers, portable glucometers are recommended for self-monitoring at home, in the field, and in research settings. The purpose was to characterize the accuracy and precision, and bias of glucometers in biomedical research. Fifteen young (20-36 years; mean = 24.5), moderately to highly active men (n = 10) and women (n = 5), defined by exercising 2 to 3 times a week for the past 6 months, were given an oral glucose tolerance test (OGTT) after an overnight fast. Participants ingested 50, 75, or 150 grams of glucose over a 5-minute period. The glucometer was compared to a reference instrument. The glucometer had 39% of values within 15% of measurements made using the reference instrument ranging from 45.05 to 169.37 mg/dl. There was both a proportional (-0.45 to -0.39) and small fixed (5.06 and 0.90 mg/dl) bias. Results of the present study suggest that the glucometer provided poor validity and reliability results compared to the results provided by the reference laboratory analyzer. The portable glucometers should be used for patient management, but not for diagnosis, treatment, or research purposes. © 2014 Diabetes Technology Society.

  3. RELIABLE COGNITIVE DIMENSIONAL DOCUMENT RANKING BY WEIGHTED STANDARD CAUCHY DISTRIBUTION

    Directory of Open Access Journals (Sweden)

    S Florence Vijila

    2017-04-01

    Full Text Available Categorization of cognitively uniform and consistent documents such as University question papers are in demand by e-learners. Literature indicates that Standard Cauchy distribution and the derived values are extensively used for checking uniformity and consistency of documents. The paper attempts to apply this technique for categorizing question papers according to four selective cognitive dimensions. For this purpose cognitive dimensional keyword sets of these four categories (also termed as portrayal concepts are assumed and an automatic procedure is developed to quantify these dimensions in question papers. The categorization is relatively accurate when checked with manual methods. Hence simple and well established term frequency / inverse document frequency ‘tf/ IDF’ technique is considered for automating the categorization process. After the documents categorization, standard Cauchy formula is applied to rank order the documents that have the least differences among Cauchy value, (according to Cauchy theorem so as obtain consistent and uniform documents in an order or ranked. For the purpose of experiments and social survey, seven question papers (documents have been designed with various consistencies. To validate this proposed technique social survey is administered on selective samples of e-learners of Tamil Nadu, India. Results are encouraging and conclusions drawn out of the experiments will be useful to researchers of concept mining and categorizing documents according to concepts. Findings have also contributed utility value to e-learning system designers.

  4. Accident Sequence Evaluation Program: Human reliability analysis procedure

    Energy Technology Data Exchange (ETDEWEB)

    Swain, A.D.

    1987-02-01

    This document presents a shortened version of the procedure, models, and data for human reliability analysis (HRA) which are presented in the Handbook of Human Reliability Analysis With emphasis on Nuclear Power Plant Applications (NUREG/CR-1278, August 1983). This shortened version was prepared and tried out as part of the Accident Sequence Evaluation Program (ASEP) funded by the US Nuclear Regulatory Commission and managed by Sandia National Laboratories. The intent of this new HRA procedure, called the ''ASEP HRA Procedure,'' is to enable systems analysts, with minimal support from experts in human reliability analysis, to make estimates of human error probabilities and other human performance characteristics which are sufficiently accurate for many probabilistic risk assessments. The ASEP HRA Procedure consists of a Pre-Accident Screening HRA, a Pre-Accident Nominal HRA, a Post-Accident Screening HRA, and a Post-Accident Nominal HRA. The procedure in this document includes changes made after tryout and evaluation of the procedure in four nuclear power plants by four different systems analysts and related personnel, including human reliability specialists. The changes consist of some additional explanatory material (including examples), and more detailed definitions of some of the terms. 42 refs.

  5. Accident Sequence Evaluation Program: Human reliability analysis procedure

    International Nuclear Information System (INIS)

    Swain, A.D.

    1987-02-01

    This document presents a shortened version of the procedure, models, and data for human reliability analysis (HRA) which are presented in the Handbook of Human Reliability Analysis With emphasis on Nuclear Power Plant Applications (NUREG/CR-1278, August 1983). This shortened version was prepared and tried out as part of the Accident Sequence Evaluation Program (ASEP) funded by the US Nuclear Regulatory Commission and managed by Sandia National Laboratories. The intent of this new HRA procedure, called the ''ASEP HRA Procedure,'' is to enable systems analysts, with minimal support from experts in human reliability analysis, to make estimates of human error probabilities and other human performance characteristics which are sufficiently accurate for many probabilistic risk assessments. The ASEP HRA Procedure consists of a Pre-Accident Screening HRA, a Pre-Accident Nominal HRA, a Post-Accident Screening HRA, and a Post-Accident Nominal HRA. The procedure in this document includes changes made after tryout and evaluation of the procedure in four nuclear power plants by four different systems analysts and related personnel, including human reliability specialists. The changes consist of some additional explanatory material (including examples), and more detailed definitions of some of the terms. 42 refs

  6. Role of secondary standard dosimetry laboratory in radiation protection program

    International Nuclear Information System (INIS)

    Rahman, Sohaila; Ali, Noriah Mohd.

    2008-01-01

    Full text: The radiation dosimetry program is an important element of operational radiation protection. Dosimetry data enable workers and radiation protection professionals to evaluate and control work practices to eliminate unnecessary exposure to ionizing radiation. The usefulness of the data produced however depends on its quality and traceability. The emphasis of the global dosimetry program is focused through the IAEA/WHO network of secondary standard dosimetry laboratories (SSDLs), which aims for the determination of SI quantities through proper traceable calibration of radiation protection equipment. The responsibility of SSDL-NUCLEAR MALAYSIA to guarantee a reliable dosimetry service, which is traceable to international standards, is elucidated. It acts as the basis for harmonized occupational radiation monitoring in Malaysia.

  7. Standardization of domestic human reliability analysis and experience of human reliability analysis in probabilistic safety assessment for NPPs under design

    International Nuclear Information System (INIS)

    Kang, D. I.; Jung, W. D.

    2002-01-01

    This paper introduces the background and development activities of domestic standardization of procedure and method for Human Reliability Analysis (HRA) to avoid the intervention of subjectivity by HRA analyst in Probabilistic Safety Assessment (PSA) as possible, and the review of the HRA results for domestic nuclear power plants under design studied by Korea Atomic Energy Research Institute. We identify the HRA methods used for PSA for domestic NPPs and discuss the subjectivity of HRA analyst shown in performing a HRA. Also, we introduce the PSA guidelines published in USA and review the HRA results based on them. We propose the system of a standard procedure and method for HRA to be developed

  8. Reliability improvement: where do we go from here. The role of codes and standards

    International Nuclear Information System (INIS)

    Davidson, R.H.

    1976-01-01

    The role of codes and standards in contributing to the future improvement is discussed. The Nuclear Plant Reliability Data System is examined. It is suggested that two systems of the type are needed. One system should focus on component and system reliability while the other should focus on system availability, capacity factor, and fixed outage rate assessment

  9. 75 FR 65964 - Version One Regional Reliability Standard for Resource and Demand Balancing

    Science.gov (United States)

    2010-10-27

    ... this record and, thus, does not persuade us.\\35\\ \\33\\ WECC's analysis shows that, over the past 15... notes that the currently approved regional Reliability Standard was established through negotiations in...

  10. Russian standards and design practice of ensuring NPP reliability under severe external loading conditions

    Energy Technology Data Exchange (ETDEWEB)

    Birbraer, A N [St. Petersburg Research and Design Institute Atomenergoproject, St. Petersburt (Russian Federation)

    1993-07-01

    Russian Standards and design practice of ensuring NPP reliability under severe external loading conditions are described. The main attention is paid to the seismic design requirements. Explosions, aircraft impact, and tornado are briefly examined too (author)

  11. Russian standards and design practice of ensuring NPP reliability under severe external loading conditions

    International Nuclear Information System (INIS)

    Birbraer, A.N.

    1993-01-01

    Russian Standards and design practice of ensuring NPP reliability under severe external loading conditions are described. The main attention is paid to the seismic design requirements. Explosions, aircraft impact, and tornado are briefly examined too (author)

  12. 77 FR 25164 - Revision to Transmission Vegetation Management Reliability Standard; Notice Inviting Comments on...

    Science.gov (United States)

    2012-04-27

    ... mathematics and documentation of the technical justification behind the application of the Gallet equation and... application in NERC- approved Reliability Standard FAC-003-2 reasonable to address the minimum distance...

  13. Establishment of quality, reliability and design standards for low, medium, and high power microwave hybrid microcircuits

    Science.gov (United States)

    Robinson, E. A.

    1973-01-01

    Quality, reliability, and design standards for microwave hybrid microcircuits were established. The MSFC Standard 85M03926 for hybrid microcircuits was reviewed and modifications were generated for use with microwave hybrid microcircuits. The results for reliability tests of microwave thin film capacitors, transistors, and microwave circuits are presented. Twenty-two microwave receivers were tested for 13,500 unit hours. The result of 111,121 module burn-in and operating hours for an integrated solid state transceiver module is reported.

  14. 1997 DOE technical standards program workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-10-01

    The Department of Energy held its annual Technical Standards Program Workshop on July 8--10, 1997, at the Loews L`Enfant Plaza Hotel in Washington, DC. The workshop focused on aspects of implementation of the National Technology Transfer and Advancement Act of 1995 [Public Law (PL) 104-113] and the related revision (still pending) to OMB Circular A119 (OMB A119), Federal Participation in the Development and Use of Voluntary Standards. It also addressed DOE`s efforts in transitioning to a standards-based operating culture, and, through this transition, to change from a developer of internal technical standards to a customer of external technical standards. The workshop was designed to provide a forum to better understand how the new law is affecting Department activities. Panel topics such as ``Public Law 104-113 and Its Influence on Federal Agency Standards Activities`` and ``Update on Global Standards Issues`` provided insight on both the internal and external effects of the new law. Keynote speaker Richard Meier of Meadowbrook International (and formerly the Deputy Assistant US Trade Representative) addressed the subject of international trade balance statistics. He pointed out that increases in US export figures do not necessarily indicate increases in employment. Rather, increased employment results from product growth. Mr Meier also discussed issues such as the US migration to the sue of the metric system, the impact of budget limitations on Government participation in voluntary standards organizations, international standards ISO 9000 and ISO 14000, and DOE`s role in the worldwide transition from weapons production to cleanup.

  15. Fuzzy Goal Programming Approach in Selective Maintenance Reliability Model

    Directory of Open Access Journals (Sweden)

    Neha Gupta

    2013-12-01

    Full Text Available 800x600 In the present paper, we have considered the allocation problem of repairable components for a parallel-series system as a multi-objective optimization problem and have discussed two different models. In first model the reliability of subsystems are considered as different objectives. In second model the cost and time spent on repairing the components are considered as two different objectives. These two models is formulated as multi-objective Nonlinear Programming Problem (MONLPP and a Fuzzy goal programming method is used to work out the compromise allocation in multi-objective selective maintenance reliability model in which we define the membership functions of each objective function and then transform membership functions into equivalent linear membership functions by first order Taylor series and finally by forming a fuzzy goal programming model obtain a desired compromise allocation of maintenance components. A numerical example is also worked out to illustrate the computational details of the method.  Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4

  16. Summary of component reliability data for probabilistic safety analysis of Korean standard nuclear power plant

    International Nuclear Information System (INIS)

    Choi, S. Y.; Han, S. H.

    2004-01-01

    The reliability data of Korean NPP that reflects the plant specific characteristics is necessary for PSA of Korean nuclear power plants. We have performed a study to develop the component reliability DB and S/W for component reliability analysis. Based on the system, we had have collected the component operation data and failure/repair data during plant operation data to 1998/2000 for YGN 3,4/UCN 3,4 respectively. Recently, we have upgraded the database by collecting additional data by 2002 for Korean standard nuclear power plants and performed component reliability analysis and Bayesian analysis again. In this paper, we supply the summary of component reliability data for probabilistic safety analysis of Korean standard nuclear power plant and describe the plant specific characteristics compared to the generic data

  17. Reliability of an interactive computer program for advance care planning.

    Science.gov (United States)

    Schubart, Jane R; Levi, Benjamin H; Camacho, Fabian; Whitehead, Megan; Farace, Elana; Green, Michael J

    2012-06-01

    Despite widespread efforts to promote advance directives (ADs), completion rates remain low. Making Your Wishes Known: Planning Your Medical Future (MYWK) is an interactive computer program that guides individuals through the process of advance care planning, explaining health conditions and interventions that commonly involve life or death decisions, helps them articulate their values/goals, and translates users' preferences into a detailed AD document. The purpose of this study was to demonstrate that (in the absence of major life changes) the AD generated by MYWK reliably reflects an individual's values/preferences. English speakers ≥30 years old completed MYWK twice, 4 to 6 weeks apart. Reliability indices were assessed for three AD components: General Wishes; Specific Wishes for treatment; and Quality-of-Life values (QoL). Twenty-four participants completed the study. Both the Specific Wishes and QoL scales had high internal consistency in both time periods (Knuder Richardson formula 20 [KR-20]=0.83-0.95, and 0.86-0.89). Test-retest reliability was perfect for General Wishes (κ=1), high for QoL (Pearson's correlation coefficient=0.83), but lower for Specific Wishes (Pearson's correlation coefficient=0.57). MYWK generates an AD where General Wishes and QoL (but not Specific Wishes) statements remain consistent over time.

  18. Reliability of an Interactive Computer Program for Advance Care Planning

    Science.gov (United States)

    Levi, Benjamin H.; Camacho, Fabian; Whitehead, Megan; Farace, Elana; Green, Michael J

    2012-01-01

    Abstract Despite widespread efforts to promote advance directives (ADs), completion rates remain low. Making Your Wishes Known: Planning Your Medical Future (MYWK) is an interactive computer program that guides individuals through the process of advance care planning, explaining health conditions and interventions that commonly involve life or death decisions, helps them articulate their values/goals, and translates users' preferences into a detailed AD document. The purpose of this study was to demonstrate that (in the absence of major life changes) the AD generated by MYWK reliably reflects an individual's values/preferences. English speakers ≥30 years old completed MYWK twice, 4 to 6 weeks apart. Reliability indices were assessed for three AD components: General Wishes; Specific Wishes for treatment; and Quality-of-Life values (QoL). Twenty-four participants completed the study. Both the Specific Wishes and QoL scales had high internal consistency in both time periods (Knuder Richardson formula 20 [KR-20]=0.83–0.95, and 0.86–0.89). Test-retest reliability was perfect for General Wishes (κ=1), high for QoL (Pearson's correlation coefficient=0.83), but lower for Specific Wishes (Pearson's correlation coefficient=0.57). MYWK generates an AD where General Wishes and QoL (but not Specific Wishes) statements remain consistent over time. PMID:22512830

  19. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  20. Design-reliability assurance program application to ACP600

    International Nuclear Information System (INIS)

    Zhichao, Huang; Bo, Zhao

    2012-01-01

    ACP600 is a newly nuclear power plant technology made by CNNC in China and it is based on the Generation III NPPs design experience and general safety goals. The ACP600 Design Reliability Assurance Program (D-RAP) is implemented as an integral part of the ACP600 design process. A RAP is a formal management system which assures the collection of important characteristic information about plant performance throughout each phase of its life and directs the use of this information in the implementation of analytical and management process which are specifically designed to meet two specific objects: confirm the plant goals and cost effective improvements. In general, typical reliability assurance program have 4 broad functional elements: 1) Goals and performance criteria; 2) Management system and implementing procedures; 3) Analytical tools and investigative methods; and 4) Information management. In this paper we will use the D-RAP technical and Risk-Informed requirements, and establish the RAM and PSA model to optimize the ACP600 design. Compared with previous design process, the D-RAP is more competent for the higher design targets and requirements, enjoying more creativity through an easier implementation of technical breakthroughs. By using D-RAP, the plants goals, system goals, performance criteria and safety criteria can be easier to realize, and the design can be optimized and more rational

  1. Standards and reliability in evaluation: when rules of thumb don't apply.

    Science.gov (United States)

    Norcini, J J

    1999-10-01

    The purpose of this paper is to identify situations in which two rules of thumb in evaluation do not apply. The first rule is that all standards should be absolute. When selection decisions are being made or when classroom tests are given, however, relative standards may be better. The second rule of thumb is that every test should have a reliability of .80 or better. Depending on the circumstances, though, the standard error of measurement, the consistency of pass/fail classifications, and the domain-referenced reliability coefficients may be better indicators of reproducibility.

  2. Department of Defense need for a micro-electromechanical systems (MEMS) reliability assessment program

    Science.gov (United States)

    Zunino, James L., III; Skelton, Donald

    2005-01-01

    As the United States (U.S.) Army transforms into a lighter, more lethal, and more agile force, the technologies that support both legacy and emerging weapon systems must decrease in size while increasing in intelligence. Micro-electromechanical systems (MEMS) are one such technology that the Army as well as entire DOD will heavily rely on in achieving these objectives. Current and future military applications of MEMS devices include safety and arming devices, guidance systems, sensors/detectors, inertial measurement units, tracking devices, radio frequency devices, wireless radio frequency identification (RFID), etc. Even though the reliance on MEMS devices has been increasing, there have been no studies performed to determine their reliability and failure mechanisms. Furthermore, no standardized test protocols exist for assessing reliability. Accordingly, the U.S. Army Corrosion Office at Picatinny, NJ has initiated the MEMS Reliability Assessment Program to address this issue.

  3. MPprimer: a program for reliable multiplex PCR primer design

    Directory of Open Access Journals (Sweden)

    Wang Xiaolei

    2010-03-01

    Full Text Available Abstract Background Multiplex PCR, defined as the simultaneous amplification of multiple regions of a DNA template or multiple DNA templates using more than one primer set (comprising a forward primer and a reverse primer in one tube, has been widely used in diagnostic applications of clinical and environmental microbiology studies. However, primer design for multiplex PCR is still a challenging problem and several factors need to be considered. These problems include mis-priming due to nonspecific binding to non-target DNA templates, primer dimerization, and the inability to separate and purify DNA amplicons with similar electrophoretic mobility. Results A program named MPprimer was developed to help users for reliable multiplex PCR primer design. It employs the widely used primer design program Primer3 and the primer specificity evaluation program MFEprimer to design and evaluate the candidate primers based on genomic or transcript DNA database, followed by careful examination to avoid primer dimerization. The graph-expanding algorithm derived from the greedy algorithm was used to determine the optimal primer set combinations (PSCs for multiplex PCR assay. In addition, MPprimer provides a virtual electrophotogram to help users choose the best PSC. The experimental validation from 2× to 5× plex PCR demonstrates the reliability of MPprimer. As another example, MPprimer is able to design the multiplex PCR primers for DMD (dystrophin gene which caused Duchenne Muscular Dystrophy, which has 79 exons, for 20×, 20×, 20×, 14×, and 5× plex PCR reactions in five tubes to detect underlying exon deletions. Conclusions MPprimer is a valuable tool for designing specific, non-dimerizing primer set combinations with constrained amplicons size for multiplex PCR assays.

  4. Standard Review Plan Update and Development Program

    International Nuclear Information System (INIS)

    1992-05-01

    This implementing procedures document (IPD) was prepared for use in implementing tasks under the standard review plan update and development program (SRP-UDP). The IPD provides comprehensive guidance and detailed procedures for SRP-UDP tasks. The IPD is mandatory for contractors performing work for the SRP-UDP. It is guidance for the staff. At the completion of the SRP-UDP, the IPD will be revised (to remove the UDP aspects) and will replace NRR Office Letter No. 800 as long-term maintenance procedures

  5. Standard Review Plan Update and Development Program

    Energy Technology Data Exchange (ETDEWEB)

    1992-05-01

    This implementing procedures document (IPD) was prepared for use in implementing tasks under the standard review plan update and development program (SRP-UDP). The IPD provides comprehensive guidance and detailed procedures for SRP-UDP tasks. The IPD is mandatory for contractors performing work for the SRP-UDP. It is guidance for the staff. At the completion of the SRP-UDP, the IPD will be revised (to remove the UDP aspects) and will replace NRR Office Letter No. 800 as long-term maintenance procedures.

  6. Development of an analysis rule of diagnosis error for standard method of human reliability analysis

    International Nuclear Information System (INIS)

    Jeong, W. D.; Kang, D. I.; Jeong, K. S.

    2003-01-01

    This paper presents the status of development of Korea standard method for Human Reliability Analysis (HRA), and proposed a standard procedure and rules for the evaluation of diagnosis error probability. The quality of KSNP HRA was evaluated using the requirement of ASME PRA standard guideline, and the design requirement for the standard HRA method was defined. Analysis procedure and rules, developed so far, to analyze diagnosis error probability was suggested as a part of the standard method. And also a study of comprehensive application was performed to evaluate the suitability of the proposed rules

  7. To the problem of reliability standardization in computer-aided manufacturing at NPP units

    International Nuclear Information System (INIS)

    Yastrebenetskij, M.A.; Shvyryaev, Yu.V.; Spektor, L.I.; Nikonenko, I.V.

    1989-01-01

    The problems of reliability standardization in computer-aided manufacturing of NPP units considering the following approaches: computer-aided manufacturing of NPP units as a part of automated technological complex; computer-aided manufacturing of NPP units as multi-functional system, are analyzed. Selection of the composition of reliability indeces for computer-aided manufacturing of NPP units for each of the approaches considered is substantiated

  8. Standardization, Validity and Reliability Study of Gülhane Aphasia Test-2 (GAT-2

    Directory of Open Access Journals (Sweden)

    İlknur Maviş

    2007-04-01

    Full Text Available OBJECTIVE: Gülhane Aphasia Test-2 (GAT-2 has been developed to show the presence of a language disorder ‘aphasia’ and to give the clinician implications for the accompanying speech disorders such as apraxia and dysarthria. OBJECTIVE: The aim of the study was to report standardization, validity and reliability study of GAT-2. METHODS: : 10 healthy individuals were tested initially for the pilot study. 134 healthy individual was included to the standardization study and 30 individuals with aphasia and 11 individuals with right brain injury was included to the validation study. The inter group GAT-2 score differentiations and the effects of age, years of education, sex variances were observed. GAT-2 cut-off scores were calculated by the scores of healthy individuals. GAT-2 test-retest reliability and inter-observer reliability was calculated. RESULTS: Healthy individuals’ GAT-2 scores were significantly different from the GAT-2 scores of aphasic patients, but not from right brain injured patients’. Healthy individuals’ GAT-2 scores were not affected from the sex, age variances but from years of education, so cut-off scores were calculated by this variance. GAT-2 scores of aphasic patients were not affected from age, sex and years of education. Test-retest and inter-observer reliability and internal consistency results showed that GAT-2 is a highly reliable aphasia screening test. CONCLUSION: GAT-2 was found to be a standardized, highly reliable and a valid aphasia test for Turkish stroke patients with aphasia

  9. Implementation of PATREC nuclear reliability program in PROLOG

    International Nuclear Information System (INIS)

    Koen, B.V.; Koen, D.B.

    1987-01-01

    PROLOG, the de facto computer language for research in artificial intelligence in Japan, is a logical choice for research in the pattern recognition strategy for evaluating the reliability of complex systems expressed as fault trees. PROLOG's basic data type is the tree, and its basic control construct is pattern matching. It is also based on recursive programming and allows dynamic allocation of memory, both of which are essential for an efficient reduction of the input tree. Since the inference engine of PROLOG automatically examines the user-defined data base in a systematic order, an additional advantage of this language is that the largest known pattern will always be found first without coding complex tree searches of the pattern library as was required in other computer languages such as PL/1 and LISP

  10. 49 CFR Appendix E to Part 238 - General Principles of Reliability-Based Maintenance Programs

    Science.gov (United States)

    2010-10-01

    ... STANDARDS Pt. 238, App. E Appendix E to Part 238—General Principles of Reliability-Based Maintenance... 49 Transportation 4 2010-10-01 2010-10-01 false General Principles of Reliability-Based... the design level of safety and reliability of the equipment; (2) To restore safety and reliability to...

  11. Reliability and acceptability of a five-station multiple mini-interview model for residency program recruitment

    Directory of Open Access Journals (Sweden)

    Julian Diaz Fraga

    2013-12-01

    Full Text Available Background: Standard interviews are used by most residency programs in the United States for assessment of aptitude of the non-cognitive competencies, but variability of interviewer skill, interviewer bias, interviewer leniency or stringency, and context specificity limit reliability. Aim: To investigate reliability and acceptability of five-station multiple mini-interview (MMI model for resident selection into an internal medicine residency program in the United States. Setting: One independent academic medical center. Participants: Two hundred and thirty-seven applicants and 17 faculty interviewers. Program description: Five, 10-min MMI stations with five different interviewers blinded to the candidate's records and one traditional 20-min interview with the program director. Candidates were rated on two items: interpersonal and communication skills, and overall performance. Program evaluation: Generalizability data showed that the reliability of our process was high (>0.9. The results of anonymous surveys demonstrated that both applicants and interviewers consider the MMI as a fair and more effective tool to evaluate non-cognitive traits, and prefer the MMI to standard interviews. Discussion: The MMI process for residency interviews can generate reliable interview results using only five stations, and it is acceptable and preferred over standard interview modalities by the applicants and faculty members of one US residency program.

  12. Monitoring system for accuracy and reliability characteristics of standard temperature measurements in WWER-440 reactors

    International Nuclear Information System (INIS)

    Stanc, S.; Repa, M.

    2001-01-01

    Description of a monitoring system for accuracy and reliability characteristics of standard temperature measurements in WWER-440 reactors and benefits obtained from its use are shown in the presentation. As standard reactor temperature measurement, coolant temperature measurement at fuel assembly outlets and in loops, entered into the In-Reactor Control System , are considered. Such systems have been implemented at two V-230 reactors and are under implementation at other four V-213 reactors. (Authors)

  13. 76 FR 66220 - Automatic Underfrequency Load Shedding and Load Shedding Plans Reliability Standards

    Science.gov (United States)

    2011-10-26

    .... I. Background A. Underfrequency Load Shedding 4. An interconnected electric power system must... generation and load within an interconnected electric power system is shown in the frequency of the system.\\4... Reliability Standards for the Bulk-Power System, Order No. 693, FERC Stats. & Regs. ] 31,242, order on reh'g...

  14. Open and Distance Education Accreditation Standards Scale: Validity and Reliability Studies

    Science.gov (United States)

    Can, Ertug

    2016-01-01

    The purpose of this study is to develop, and test the validity and reliability of a scale for the use of researchers to determine the accreditation standards of open and distance education based on the views of administrators, teachers, staff and students. This research was designed according to the general descriptive survey model since it aims…

  15. 77 FR 59151 - Regional Reliability Standard PRC-006-NPCC-1-Automatic Underfrequency Load Shedding

    Science.gov (United States)

    2012-09-26

    ... approval. The proposed regional Reliability Standard applies to generator owners, planning coordinators... Commission, Secretary of the Commission, 888 First Street NE., Washington, DC 20426. Instructions: For... Commission, 888 First Street NE., Washington, DC 20426, Telephone: (202) 502-6750, [email protected

  16. Standardized Patients Provide a Reliable Assessment of Athletic Training Students' Clinical Skills

    Science.gov (United States)

    Armstrong, Kirk J.; Jarriel, Amanda J.

    2016-01-01

    Context: Providing students reliable objective feedback regarding their clinical performance is of great value for ongoing clinical skill assessment. Since a standardized patient (SP) is trained to consistently portray the case, students can be assessed and receive immediate feedback within the same clinical encounter; however, no research, to our…

  17. 75 FR 59261 - Mandatory Reliability Standards for the Bulk Power System; Supplemental Notice of Technical...

    Science.gov (United States)

    2010-09-27

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket Nos. RM06-16-010; RM06-16-011] Mandatory Reliability Standards for the Bulk Power System; Supplemental Notice of Technical Conference September 17, 2010. On August 19, 2010 the Federal Energy Regulatory Commission announced that a Technical...

  18. Standard high-reliability integrated circuit logic packaging. [for deep space tracking stations

    Science.gov (United States)

    Slaughter, D. W.

    1977-01-01

    A family of standard, high-reliability hardware used for packaging digital integrated circuits is described. The design transition from early prototypes to production hardware is covered and future plans are discussed. Interconnections techniques are described as well as connectors and related hardware available at both the microcircuit packaging and main-frame level. General applications information is also provided.

  19. 75 FR 57764 - Mandatory Reliability Standards for the Bulk Power System; Supplemental Notice of Technical...

    Science.gov (United States)

    2010-09-22

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket Nos. RM06-16-010; RM06-16-011] Mandatory Reliability Standards for the Bulk Power System; Supplemental Notice of Technical Conference September 14, 2010. On August 19, 2010 the Federal Energy Regulatory Commission announced that a Technical...

  20. 75 FR 61478 - Mandatory Reliability Standards for the Bulk Power System; Notice Allowing Post-Technical...

    Science.gov (United States)

    2010-10-05

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket Nos. RM06-16-010; RM06-16-011] Mandatory Reliability Standards for the Bulk Power System; Notice Allowing Post-Technical Conference Comments September 24, 2010. On September 23, 2010, the Federal Energy Regulatory Commission conducted a...

  1. 14 CFR 151.99 - Modifications of programming standards.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Modifications of programming standards. 151... (CONTINUED) AIRPORTS FEDERAL AID TO AIRPORTS Project Programming Standards § 151.99 Modifications of programming standards. The Director, Airports, Service, or the Regional Director concerned may, on individual...

  2. Development of A Standard Method for Human Reliability Analysis (HRA) of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kang, Dae Il; Jung, Won Dea; Kim, Jae Whan

    2005-12-01

    According as the demand of risk-informed regulation and applications increase, the quality and reliability of a probabilistic safety assessment (PSA) has been more important. KAERI started a study to standardize the process and the rules of HRA (Human Reliability Analysis) which was known as a major contributor to the uncertainty of PSA. The study made progress as follows; assessing the level of quality of the HRAs in Korea and identifying the weaknesses of the HRAs, determining the requirements for developing a standard HRA method, developing the process and rules for quantifying human error probability. Since the risk-informed applications use the ASME and ANS PSA standard to ensure PSA quality, the standard HRA method was developed to meet the ASME and ANS HRA requirements with level of category II. The standard method was based on THERP and ASEP HRA that are widely used for conventional HRA. However, the method focuses on standardizing and specifying the analysis process, quantification rules and criteria to minimize the deviation of the analysis results caused by different analysts. Several HRA experts from different organizations in Korea participated in developing the standard method. Several case studies were interactively undertaken to verify the usability and applicability of the standard method

  3. Development of A Standard Method for Human Reliability Analysis of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Jung, Won Dea; Kang, Dae Il; Kim, Jae Whan

    2005-12-01

    According as the demand of risk-informed regulation and applications increase, the quality and reliability of a probabilistic safety assessment (PSA) has been more important. KAERI started a study to standardize the process and the rules of HRA (Human Reliability Analysis) which was known as a major contributor to the uncertainty of PSA. The study made progress as follows; assessing the level of quality of the HRAs in Korea and identifying the weaknesses of the HRAs, determining the requirements for developing a standard HRA method, developing the process and rules for quantifying human error probability. Since the risk-informed applications use the ASME PSA standard to ensure PSA quality, the standard HRA method was developed to meet the ASME HRA requirements with level of category II. The standard method was based on THERP and ASEP HRA that are widely used for conventional HRA. However, the method focuses on standardizing and specifying the analysis process, quantification rules and criteria to minimize the deviation of the analysis results caused by different analysts. Several HRA experts from different organizations in Korea participated in developing the standard method. Several case studies were interactively undertaken to verify the usability and applicability of the standard method

  4. Development of A Standard Method for Human Reliability Analysis of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Won Dea; Kang, Dae Il; Kim, Jae Whan

    2005-12-15

    According as the demand of risk-informed regulation and applications increase, the quality and reliability of a probabilistic safety assessment (PSA) has been more important. KAERI started a study to standardize the process and the rules of HRA (Human Reliability Analysis) which was known as a major contributor to the uncertainty of PSA. The study made progress as follows; assessing the level of quality of the HRAs in Korea and identifying the weaknesses of the HRAs, determining the requirements for developing a standard HRA method, developing the process and rules for quantifying human error probability. Since the risk-informed applications use the ASME PSA standard to ensure PSA quality, the standard HRA method was developed to meet the ASME HRA requirements with level of category II. The standard method was based on THERP and ASEP HRA that are widely used for conventional HRA. However, the method focuses on standardizing and specifying the analysis process, quantification rules and criteria to minimize the deviation of the analysis results caused by different analysts. Several HRA experts from different organizations in Korea participated in developing the standard method. Several case studies were interactively undertaken to verify the usability and applicability of the standard method.

  5. Development of A Standard Method for Human Reliability Analysis (HRA) of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dae Il; Jung, Won Dea; Kim, Jae Whan

    2005-12-15

    According as the demand of risk-informed regulation and applications increase, the quality and reliability of a probabilistic safety assessment (PSA) has been more important. KAERI started a study to standardize the process and the rules of HRA (Human Reliability Analysis) which was known as a major contributor to the uncertainty of PSA. The study made progress as follows; assessing the level of quality of the HRAs in Korea and identifying the weaknesses of the HRAs, determining the requirements for developing a standard HRA method, developing the process and rules for quantifying human error probability. Since the risk-informed applications use the ASME and ANS PSA standard to ensure PSA quality, the standard HRA method was developed to meet the ASME and ANS HRA requirements with level of category II. The standard method was based on THERP and ASEP HRA that are widely used for conventional HRA. However, the method focuses on standardizing and specifying the analysis process, quantification rules and criteria to minimize the deviation of the analysis results caused by different analysts. Several HRA experts from different organizations in Korea participated in developing the standard method. Several case studies were interactively undertaken to verify the usability and applicability of the standard method.

  6. Implementing a Reliability Centered Maintenance Program at NASA's Kennedy Space Center

    National Research Council Canada - National Science Library

    Tuttle, Raymond

    1998-01-01

    .... A reliability centered maintenance (RCM) program seeks to offer equal or greater reliability at decreased cost by insuring only applicable, effective maintenance is performed and by in large part replacing time based maintenance...

  7. The national standards program for research reactors

    International Nuclear Information System (INIS)

    Whittemore, W.L.

    1977-01-01

    In 1970 a standards committee called ANS-15 was established by the American Nuclear Society (ANS) to prepare appropriate standards for research reactors. In addition, ANS acts as Secretariat for a national standards committee N17 which is responsible to the American National Standards Institute (ANSI) for the national consensus efforts for standards related to research reactors. To date ANS-15 has completed or is working on 14 standards covering all aspects of the operation of research reactors. Of the 11 research reactor standards submitted to the ANSI N17 Committee since its inception, six have been issued as National standards, and the remaining are still in the process of review. (author)

  8. Leveraging Standards to Promote Program Quality

    Science.gov (United States)

    Young, Michelle D.; Mawhinney, Hanna; Reed, Cynthia J.

    2016-01-01

    Standards provide a foundation for thinking about leadership development and practice. This article explores three sets of standards that impact educational leadership preparation: (a) the recently revised Interstate School Leaders Licensure Consortium (ISLLC) standards, which are now known as the Practice Standards for Educational Leaders (PSEL);…

  9. The Children's Body Image Scale: reliability and use with international standards for body mass index.

    Science.gov (United States)

    Truby, Helen; Paxton, Susan J

    2008-03-01

    To test the reliability of the Children's Body Image Scale (CBIS) and assess its usefulness in the context of new body size charts for children. Participants were 281 primary schoolchildren with 50% being retested after 3 weeks. The CBIS figure scale was compared with a range of international body mass index (BMI) reference standards. Children had a high degree of body image dissatisfaction. The test-retest reliability of the CBIS was supported. The CBIS is a useful tool for assessing body image in children with sound scale properties. It can also be used to identify the body size of children, which lies outside the healthy weight range of BMI.

  10. SIMON. A computer program for reliability and statistical analysis using Monte Carlo simulation. Program description and manual

    International Nuclear Information System (INIS)

    Kongsoe, H.E.; Lauridsen, K.

    1993-09-01

    SIMON is a program for calculation of reliability and statistical analysis. The program is of the Monte Carlo type, and it is designed with high flexibility, and has a large potential for application to complex problems like reliability analyses of very large systems and of systems, where complex modelling or knowledge of special details are required. Examples of application of the program, including input and output, for reliability and statistical analysis are presented. (au) (3 tabs., 3 ills., 5 refs.)

  11. Exploration of reliability assurance program (RAP) for advanced nuclear power plant

    International Nuclear Information System (INIS)

    Chen Fang; Xu Rongbin

    2009-01-01

    This article describes the new requirements in US SRP on Reliability Assurance Program, inquires into the evolution of the reliability assurance requirements, and investigates the regulatory requirements on reliability assurance program for advanced reactors, it's main contents, and evaluation review practices and related issues, with the aim of enabling staff to understand be familiar and pay attention to this engineering program. This article may be as a reference for related workers. (authors)

  12. 78 FR 79567 - National School Lunch Program and School Breakfast Program: Nutrition Standards for All Foods...

    Science.gov (United States)

    2013-12-31

    ... Program: Nutrition Standards for All Foods Sold in Schools as Required by the Healthy, Hunger-Free Kids... interim rule entitled National School Lunch Program and School Breakfast Program: Nutrition Standards for..., 2013 / Rules and Regulations [[Page 79567

  13. [The analytical reliability of clinical laboratory information and role of the standards in its support].

    Science.gov (United States)

    Men'shikov, V V

    2012-12-01

    The article deals with the factors impacting the reliability of clinical laboratory information. The differences of qualities of laboratory analysis tools produced by various manufacturers are discussed. These characteristics are the causes of discrepancy of the results of laboratory analyses of the same analite. The role of the reference system in supporting the comparability of laboratory analysis results is demonstrated. The project of national standard is presented to regulate the requirements to standards and calibrators for analysis of qualitative and non-metrical characteristics of components of biomaterials.

  14. Implementation of PATREC nuclear reliability program in LISP

    International Nuclear Information System (INIS)

    Patterson-Hine, F.A.; Koen, B.V.

    1985-01-01

    The reliability of large systems can be represented by reliability fault trees that contain the failure probabilities for the individual elements in the original network and the logical connectives that describe the interdependence of those probabilities. The PATREC 1 computer code was written to demonstrate the feasibility of using list processing techniques for the resolution of a reliability fault tree by pattern recognition. PATREC 1 was written in PL/1 and is used widely in France. The fault tree is expressed as a linked data structure, oriented, mapped into an end-ordered traverse, and used to retrieve known patterns stored as a linked-tree library. The basic idea of pattern recognition is to prune the fault tree by identifying known patterns, retrieving the corresponding mathematical equation, and evaluating the replacement leaves. This process is repeated until the original tree is reduced to a single leaf - the system reliability

  15. Reliability program plan for the Kilowatt Isotope Power System (KIPS) technology verification phase

    International Nuclear Information System (INIS)

    1978-01-01

    Ths document is an integral part of the Kilowatt Isotope Power System (KIPS) Program Plan. This document defines the KIPS Reliability Program Plan for the Technology Verification Phase. This document delineates the reliability assurance tasks that are to be accomplished by Sundstrand and its suppliers during the design, fabrication and testing of the KIPS

  16. DATMAN: A reliability data analysis program using Bayesian updating

    International Nuclear Information System (INIS)

    Becker, M.; Feltus, M.A.

    1996-01-01

    Preventive maintenance (PM) techniques focus on the prevention of failures, in particular, system components that are important to plant functions. Reliability-centered maintenance (RCM) improves on the PM techniques by introducing a set of guidelines by which to evaluate the system functions. It also minimizes intrusive maintenance, labor, and equipment downtime without sacrificing system performance when its function is essential for plant safety. Both the PM and RCM approaches require that system reliability data be updated as more component failures and operation time are acquired. Systems reliability and the likelihood of component failures can be calculated by Bayesian statistical methods, which can update these data. The DATMAN computer code has been developed at Penn State to simplify the Bayesian analysis by performing tedious calculations needed for RCM reliability analysis. DATMAN reads data for updating, fits a distribution that best fits the data, and calculates component reliability. DATMAN provides a user-friendly interface menu that allows the user to choose from several common prior and posterior distributions, insert new failure data, and visually select the distribution that matches the data most accurately

  17. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Science.gov (United States)

    Tidstrand, Johan; Horneij, Eva

    2009-01-01

    Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar

  18. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Directory of Open Access Journals (Sweden)

    Tidstrand Johan

    2009-06-01

    Full Text Available Abstract Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs. Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0, for sitting on a Bobath ball good (κ: 0.79 and very good (κ: 0.88 and for the unilateral pelvic lift: good (κ: 0.61 and moderate (κ: 0.47. Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their

  19. Validity, Reliability and Standardization Study of the Language Assessment Test for Aphasia

    Directory of Open Access Journals (Sweden)

    Bülent Toğram

    2012-09-01

    Full Text Available OBJECTIVE: Aphasia assessment is the first step towards a well- founded language therapy. Language tests need to consider cultural as well as typological linguistic aspects of a given language. This study was designed to determine the standardization, validity and reliability of Language Assessment Test for Aphasia, which consists of eight subtests including spontaneous speech and language, auditory comprehension, repetition, naming, reading, grammar, speech acts, and writing. METHODS: The test was administered to 282 healthy participants and 92 aphasic participants in age, education and gender matched groups. The validity study of the test was investigated with analysis of content, structure and criterion-related validity. For reliability of the test, the analysis of internal consistency, stability and equivalence reliability was conducted. The influence of variables on healhty participants’ sub-test scores, test score and language score was examined. According to significant differences, norms and cut-off scores based on language score were determined. RESULTS: The group with aphasia performed highly lower than healthy participants on subtest, test and language scores. The test scores of healthy group were mostly affected by age and educational level but not affected by gender. According to significant differences, age and educational level for both groups were determined. Considering age and educational levels, the reference values for the cut-off scores were presented. CONCLUSION: The test was found to be a highly reliable and valid aphasia test for Turkish- speaking aphasic patients either in Turkey or other Turkish communities around the world

  20. Reliability and validity of the Farsi version of the standardized assessment of personality-abbreviated scale

    Directory of Open Access Journals (Sweden)

    Maryam Sepehri

    2017-06-01

    Full Text Available Introduction: A short screening tool for high-risk individuals with personality disorder (PD is useful both for clinicians and researchers. The aim of this study was to assess the validity and reliability of the Farsi version of the Standardized Assessment of Personality-Abbreviated Scale (SAPAS. Methods: The original English version of the SAPAS questionnaire was translated into Farsi, and then, translated back into English by two professionals. A survey was then conducted using the questionnaire on 150 clients of primary health care centers in Tabriz, Iran. A total of 235 medical students were also studied for the reliability assessment of the questionnaire. The SAPAS was compared to the short form of Minnesota Multiphasic Personality Inventory (MMPI. The data analysis was performed using receiver operating characteristic (ROC curve technique, operating characteristic for diagnostic efficacy, Cronbach's alpha, and test-retest for reliability evaluation. Results: We found an area under the curve (AUC of 0.566 [95% confidence intervals (CI: 0.455-0.677]; sensitivity of 0.89 and specificity of 0.26 at the cut-off score of 2 and higher. The total Cronbach's alpha coefficient was 0.38 and Cohen's kappa ranged between 0.5 and 0.8. Conclusion: The current study showed that the Farsi version of the SAPAS was relatively less efficient, in term of validity and reliability, in the screening of PD in the population.

  1. The United States nuclear plant reliability data program: Its description and status

    International Nuclear Information System (INIS)

    Wise, M.J.

    1975-01-01

    The American National Standards Institute Subcommittee N18-20 has developed and implemented the United States Nuclear Plant Reliability Data System (NPRDS). The NPRDS is designed to accumulate, store, analyse, and report reliability and failure statistics on systems and components of nuclear power plants related to nuclear safety. Input data to the NPRDS consist of engineering, operating, and failure information submitted on a voluntary basis by participating utilities. Prior to entry into the computerized data base, the data are thoroughly checked for accuracy by both the submitting organizations and the NPRDS operating contractor. The data base is the source of various periodic output reports to the nuclear power industry and is utilized to produce special reports upon request. The present data base represents data accumulated from about thirty nuclear units with additional units expected to begin submitting data immediately. The objective is to have essentially all operating nuclear units in the United States of America participating in the program by the end of 1975. The first NPRDS annual reports containing meaningful reliability and failure statistics are expected to be produced following the end of 1975. (author)

  2. NASA software documentation standard software engineering program

    Science.gov (United States)

    1991-01-01

    The NASA Software Documentation Standard (hereinafter referred to as Standard) can be applied to the documentation of all NASA software. This Standard is limited to documentation format and content requirements. It does not mandate specific management, engineering, or assurance standards or techniques. This Standard defines the format and content of documentation for software acquisition, development, and sustaining engineering. Format requirements address where information shall be recorded and content requirements address what information shall be recorded. This Standard provides a framework to allow consistency of documentation across NASA and visibility into the completeness of project documentation. This basic framework consists of four major sections (or volumes). The Management Plan contains all planning and business aspects of a software project, including engineering and assurance planning. The Product Specification contains all technical engineering information, including software requirements and design. The Assurance and Test Procedures contains all technical assurance information, including Test, Quality Assurance (QA), and Verification and Validation (V&V). The Management, Engineering, and Assurance Reports is the library and/or listing of all project reports.

  3. Technical Analysis Program / Flight Standards Automation System -

    Data.gov (United States)

    Department of Transportation — 1-TAP is a national data quality application 2-Logbook is field office tracking and suspense program for investigation tracking and certification tracking 3-Numerous...

  4. Developing a system engineering program to improve performance and reliability

    International Nuclear Information System (INIS)

    Keuter, D.

    1985-01-01

    After several maintenance, operational, and equipment problems last year, Trojan set out on a mission to improve plant performance and reliability by strengthening its on-site engineering organization. This paper presents Trojan's plans in developing an on-site system engineering organization

  5. EDF/EPRI collaborative program on operator reliability experiments

    International Nuclear Information System (INIS)

    Villemeur, A.; Meslin, T.; Mosneron, F.; Worledge, D.H.; Joksimovich, V.; Spurgin, A.J.

    1988-01-01

    Electricite de France (EDF) and Electric Power Research Institute (EPRI) have been involved in human reliability studies over the last few years, in the context of improvements in human reliability assessment (HRA) methodologies, and have been following a systematic process since 1982 which consists of addressing the following five ingredients: - First, classify human interactions into a limited number of classes. - Second, introduce an acceptable framework to organize the application of HRA to PRA studies. - Third, select approach(es) to quantification. - Fourth, test promising models. - Fifth, establish an appropriate data base for tested model(s) with regard to specific applications. EPRI has just recently completed Phase I of the fourth topic. This primarily focused on testing the fundamental hypotheses behing the human cognitive reliability (HCR) correlation, using power plant simulators. EDF has been carrying out simulator studies since 1980, both for man-machine interface validation and HRA data collection. This background of experience provided a stepping stone for the EPRI project. On the other hand, before 1986, EDF had mainly been concentrating on getting qualitative insights from the tests and lacked experience in quantitative analysis and modeling, while EPRI had made advances in this latter area. Before the EPRI Operator Reliability Experiments (ORE) project was initiated, it was abundantly clear to EPRI and EDF that cooperation between the two could be useful and that both parties could gain from the cooperation

  6. Reliability studies for the nuclear-powered artificial heart program

    International Nuclear Information System (INIS)

    Horita, M.; Zeigler, R.K.

    1976-04-01

    By assuming that the failures of an artificial heart system with a mean life of 10 y can be modeled by a particular probability distribution, both the probability of a failure in the system within t years and the reliability required of each subsystem and component were investigated

  7. Standard semiconductor packaging for high-reliability low-cost MEMS applications

    Science.gov (United States)

    Harney, Kieran P.

    2005-01-01

    Microelectronic packaging technology has evolved over the years in response to the needs of IC technology. The fundamental purpose of the package is to provide protection for the silicon chip and to provide electrical connection to the circuit board. Major change has been witnessed in packaging and today wafer level packaging technology has further revolutionized the industry. MEMS (Micro Electro Mechanical Systems) technology has created new challenges for packaging that do not exist in standard ICs. However, the fundamental objective of MEMS packaging is the same as traditional ICs, the low cost and reliable presentation of the MEMS chip to the next level interconnect. Inertial MEMS is one of the best examples of the successful commercialization of MEMS technology. The adoption of MEMS accelerometers for automotive airbag applications has created a high volume market that demands the highest reliability at low cost. The suppliers to these markets have responded by exploiting standard semiconductor packaging infrastructures. However, there are special packaging needs for MEMS that cannot be ignored. New applications for inertial MEMS devices are emerging in the consumer space that adds the imperative of small size to the need for reliability and low cost. These trends are not unique to MEMS accelerometers. For any MEMS technology to be successful the packaging must provide the basic reliability and interconnection functions, adding the least possible cost to the product. This paper will discuss the evolution of MEMS packaging in the accelerometer industry and identify the main issues that needed to be addressed to enable the successful commercialization of the technology in the automotive and consumer markets.

  8. Development of a standard for computer program verification and control

    International Nuclear Information System (INIS)

    Dunn, T.E.; Ozer, O.

    1980-01-01

    It is expected that adherence to the guidelines of the ANS 10.4 will: 1. Provide confidence that the program conforms to its requirements specification; 2. Provide confidence that the computer program has been adequately evaluated and tested; 3. Provide confidence that program changes are adequately evaluated, tested, and controlled; and 4. Enhance assurance that reliable data will be produced for engineering, scientific, and safety analysis purposes

  9. The two errors of using the within-subject standard deviation (WSD) as the standard error of a reliable change index.

    Science.gov (United States)

    Maassen, Gerard H

    2010-08-01

    In this Journal, Lewis and colleagues introduced a new Reliable Change Index (RCI(WSD)), which incorporated the within-subject standard deviation (WSD) of a repeated measurement design as the standard error. In this note, two opposite errors in using WSD this way are demonstrated. First, being the standard error of measurement of only a single assessment makes WSD too small when practice effects are absent. Then, too many individuals will be designated reliably changed. Second, WSD can grow unlimitedly to the extent that differential practice effects occur. This can even make RCI(WSD) unable to detect any reliable change.

  10. Special Education Compliance: Program Review Standards and Indicators.

    Science.gov (United States)

    Missouri State Dept. of Elementary and Secondary Education, Jefferson City. Div. of Special Education.

    This manual contains special education standards and indicators for educating children with disabilities in Missouri. It is divided into four main sections. Section 1 contains special education compliance standards based upon the federal Office of Special Education Programs Continuous Improvement Monitoring Program clusters and indicators. The…

  11. Video training and certification program improves reliability of postischemic neurologic deficit measurement in the rat.

    Science.gov (United States)

    Taninishi, Hideki; Pearlstein, Molly; Sheng, Huaxin; Izutsu, Miwa; Chaparro, Rafael E; Goldstein, Larry B; Warner, David S

    2016-12-01

    Scoring systems are used to measure behavioral deficits in stroke research. Video-assisted training is used to standardize stroke-related neurologic deficit scoring in humans. We hypothesized that a video-assisted training and certification program can improve inter-rater reliability in assessing neurologic function after middle cerebral artery occlusion in rats. Three expert raters scored neurologic deficits in post-middle cerebral artery occlusion rats using three published systems having different complexity levels (3, 18, or 48 points). The system having the highest point estimate for the correlation between neurologic score and infarct size was selected to create a video-assisted training and certification program. Eight trainee raters completed the video-assisted training and certification program. Inter-rater agreement ( Κ: score) and agreement with expert consensus scores were measured before and after video-assisted training and certification program completion. The 48-point system correlated best with infarct size. Video-assisted training and certification improved agreement with expert consensus scores (pretraining = 65 ± 10, posttraining = 87 ± 14, 112 possible scores, P  0.4 (pretraining = 4, posttraining = 9), and number of categories with an improvement in the Κ: score from pretraining to posttraining (n = 6). Video-assisted training and certification improved trainee inter-rater reliability and agreement with expert consensus behavioral scores in rats after middle cerebral artery occlusion. Video-assisted training and certification may be useful in multilaboratory preclinical studies. © The Author(s) 2015.

  12. Development of reliability-based design and assessment standards for onshore gas transmission pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Joe; Rothwell, Brian [TransCanada PipeLines Ltd., Calgary, AB (Canada); Nessim, Maher; Zhou, Wenxing [C-FER Technologies, Edmonton, AB (Canada)

    2005-07-01

    Onshore pipelines have traditionally been designed with a deterministic stress based methodology. The changing operating environment has however imposed many challenges to the pipeline industry, including heightened public awareness of risk, more challenging natural hazards and increased economic competitiveness. To meet the societal expectation of pipeline safety and enhance the competitiveness of the pipeline industry, significant efforts have been spent for the development of reliability-based design and assessment (RBDA) methodology. This paper will briefly review the technology development in the RBDA area and the focus will be on the progresses in the past years in standard development within the American Society of Mechanical Engineers (ASME) and the Canadian Standard Association (CSA) organizations. (author)

  13. Reliability of linear distance measurement for dental implant length with standardized periapical radiographs

    International Nuclear Information System (INIS)

    Wakoh, Mamoru; Harada, Takuya; Otonari, Takamichi

    2006-01-01

    The purpose of this study was to investigate the accuracy of distance measurements of implant length based on periapical radiographs compared with that of other modalities. We carried out an experimental trial to compare precision in distance measurement. Dental implant fixtures were buried in the canine and first molar regions. These were then subjected to periapical (PE) radiography, panoramic (PA) radiography conventional (CV) and medical computed (CT) tomography. The length of the implant fixture on each film was measured by nine observers and degree of precision was statistically analyzed. The precision of both PE radiographs and CT tomograms was closest at the highest level. Standardized PE radiography, in particular, was superior to CT tomography in the first molar region. This suggests that standardized PE radiographs should be utilized as a reliable modality for longitudinal and linear distance measurement, depending on implant length at local implantation site. (author)

  14. ECOTOURISM CERTIFICATION PROGRAMS: STANDARDS AND BENEFITS

    Directory of Open Access Journals (Sweden)

    Mariia Holub

    2015-11-01

    Full Text Available The problem of researching the ecotourism certification processes in the world is very up-to-date nowadays. The relevance of the research is stipulated by current state of environ-mental pollutants, the development of sustainable politics implementation and the fact that now people aware of real danger of environmental catastrophe that threatens the survival of civilization. That’s why the purpose of the article is conducting a complex analysis of foreign ecotourism certi-fication programs. Moreover, it is necessary to study the evolution of ecotourism development to understand the key issues of this problem. The object of this article is the analysis of ecotourism certification worldwide. The subject of the article is the detection of theoretical, methodological and practical aspects of implementation of effective ecotourism certification programs in Ukraine. To clarify all aspects of studying this issue it is necessary to use such theoretical and methodological basis as: modern theories of the genesis and evolution of ecological tourism, logical and analogy analysis, historical method, hypothetical method, classification and graphical method. Using such methods it was found that the development of ecotourism formation has taking three evolutionary steps, which affected the creation of its definition. This fact reveals the classification of different types of sustainable tourism and provides an impetus of ecotourism certification studies. Moreover, it was identified that there is a logical regularity in ecotourism certification programs all over the world. As the result, it was found that practically all the ecotourism certification processes are functioning successfully nowadays. By the way, it can be observed the rapid increase in the amount of ecocertified companies. Moreover, the programs which were analyzed in this article were divided into several steps (depends on the ecotourism certification program following which a company can

  15. Reliability program plan for the Isotope Brayton Ground Demonstration System (phase I)

    International Nuclear Information System (INIS)

    1975-01-01

    The reliability and quality assurance organizational relationships, the methods to be used, the tasks to be completed, and the documentation to be published are presented. The total program is intended to provide the necessary reliability and quality assurance associated with the design, fabrication, and testing of the GDS. It is consistent with the general objectives of the ERDA Quality Assurance (QA) program requirements document ''SNS-1'' dated April 1972 and reliability program requirements document ''SNS-2'' dated 17 June 1974 but has been specifically modified for the GDS with the intent of establishing background data for the subsequent Phase II effort

  16. Reliability and validity of the Korean standard pattern identification for stroke (K-SPI-Stroke questionnaire

    Directory of Open Access Journals (Sweden)

    Kang Byoung-Kab

    2012-04-01

    Full Text Available Abstract Background The present study was conducted to examine the reliability and validity of the ‘Korean Standard Pattern Identification for Stroke (K-SPI-Stroke’, which was developed and evaluated within the context of traditional Korean medicine (TKM. Methods Between September 2006 and December 2010, 2,905 patients from 11 Korean medical hospitals were asked to complete the K-SPI-Stroke questionnaire as a part of project ' Fundamental study for the standardization and objectification of pattern identification in traditional Korean medicine for stroke (SOPI-Stroke. Each patient was independently diagnosed by two TKM physicians from the same site according to one of four patterns, as suggested by the Korea Institute of Oriental Medicine: 1 a Qi deficiency pattern, 2 a Dampness-phlegm pattern, 3 a Yin deficiency pattern, or 4 a Fire-heat pattern. We estimated the internal consistency using Cronbach’s α coefficient, the discriminant validity using the means score of patterns, and the predictive validity using the classification accuracy of the K-SPI-Stroke questionnaire. Results The K-SPI-Stroke questionnaire had satisfactory internal consistency (α = 0.700 and validity, with significant differences in the mean of scores among the four patterns. The overall classification accuracy of this questionnaire was 65.2 %. Conclusion These results suggest that the K-SPI-Stroke questionnaire is a reliable and valid instrument for estimating the severity of the four patterns.

  17. Mobile phone radiation health risk controversy: the reliability and sufficiency of science behind the safety standards.

    Science.gov (United States)

    Leszczynski, Dariusz; Xu, Zhengping

    2010-01-27

    There is ongoing discussion whether the mobile phone radiation causes any health effects. The International Commission on Non-Ionizing Radiation Protection, the International Committee on Electromagnetic Safety and the World Health Organization are assuring that there is no proven health risk and that the present safety limits protect all mobile phone users. However, based on the available scientific evidence, the situation is not as clear. The majority of the evidence comes from in vitro laboratory studies and is of very limited use for determining health risk. Animal toxicology studies are inadequate because it is not possible to "overdose" microwave radiation, as it is done with chemical agents, due to simultaneous induction of heating side-effects. There is a lack of human volunteer studies that would, in unbiased way, demonstrate whether human body responds at all to mobile phone radiation. Finally, the epidemiological evidence is insufficient due to, among others, selection and misclassification bias and the low sensitivity of this approach in detection of health risk within the population. This indicates that the presently available scientific evidence is insufficient to prove reliability of the current safety standards. Therefore, we recommend to use precaution when dealing with mobile phones and, whenever possible and feasible, to limit body exposure to this radiation. Continuation of the research on mobile phone radiation effects is needed in order to improve the basis and the reliability of the safety standards.

  18. Mobile phone radiation health risk controversy: the reliability and sufficiency of science behind the safety standards

    Directory of Open Access Journals (Sweden)

    Leszczynski Dariusz

    2010-01-01

    Full Text Available Abstract There is ongoing discussion whether the mobile phone radiation causes any health effects. The International Commission on Non-Ionizing Radiation Protection, the International Committee on Electromagnetic Safety and the World Health Organization are assuring that there is no proven health risk and that the present safety limits protect all mobile phone users. However, based on the available scientific evidence, the situation is not as clear. The majority of the evidence comes from in vitro laboratory studies and is of very limited use for determining health risk. Animal toxicology studies are inadequate because it is not possible to "overdose" microwave radiation, as it is done with chemical agents, due to simultaneous induction of heating side-effects. There is a lack of human volunteer studies that would, in unbiased way, demonstrate whether human body responds at all to mobile phone radiation. Finally, the epidemiological evidence is insufficient due to, among others, selection and misclassification bias and the low sensitivity of this approach in detection of health risk within the population. This indicates that the presently available scientific evidence is insufficient to prove reliability of the current safety standards. Therefore, we recommend to use precaution when dealing with mobile phones and, whenever possible and feasible, to limit body exposure to this radiation. Continuation of the research on mobile phone radiation effects is needed in order to improve the basis and the reliability of the safety standards.

  19. Development of reliability and probabilistic safety assessment program RiskA

    International Nuclear Information System (INIS)

    Wu, Yican

    2015-01-01

    Highlights: • There are four parts in the structure of RiskA. User input part lets users input the PSA model and some necessary data by GUI or model transformation tool. In calculation engine part, fault tree analysis, event tree analysis, uncertainty analysis, sensitivity analysis, importance analysis and failure mode and effects analysis are supplied. User output part outputs the analysis results, user customized reports and some other data. The last part includes reliability database, some other common tools and help documents. • RiskA has several advanced features. Extensible framework makes it easy to add any new functions, making RiskA to be a large platform of reliability and probabilistic safety assessment. It is very fast to analysis fault tree in RiskA because many advanced algorithm improvement were made. Many model formats can be imported and exported, which made the PSA model in the commercial software can be easily transformed to adapt RiskA platform. Web-based co-modeling let several users in different places work together whenever they are online. • The comparison between RiskA and other mature PSA codes (e.g. CAFTA, RiskSpectrum, XFTA) has demonstrated that the calculation and analysis of RiskA is correct and efficient. Based on the development of this code package, many applications of safety and reliability analysis of some research reactors and nuclear power plants were performed. The development of RiskA appears to be of realistic and potential value for academic research and practical operation safety management of nuclear power plants in China and abroad. - Abstract: PSA (probabilistic safety assessment) software, the indispensable tool in nuclear safety assessment, has been widely used. An integrated reliability and PSA program named RiskA has been developed by FDS Team. RiskA supplies several standard PSA modules including fault tree analysis, event tree analysis, uncertainty analysis, failure mode and effect analysis and reliability

  20. The Reliable Replacement Warhead Program: Background and Current Developments

    National Research Council Canada - National Science Library

    Medalia, Jonathan

    2008-01-01

    ...), part of a larger Stockpile Stewardship Program (SSP), replaces components. Modifying some components would require a nuclear test, but the United States has observed a test moratorium since 1992...

  1. Use of reliability data for QA program evaluation

    International Nuclear Information System (INIS)

    Guarro, S.B.

    1985-01-01

    Possible analytical approaches for evaluation of the effectiveness in the operation of US commercial nuclear power plants are discussed. These approaches may be based on key plant component performance comparisons, correlation models, or comprehensive cost-benefit evaluation frameworks. As plant availability and reliability data must be used to quantify the models, the quality of these data conditions the amount of information that can ultimately be extracted. The potential impact of uncertainties in the data must be considered carefully, especially before application of the more complex models. 10 refs., 4 tabs

  2. Development of reliability program for emergency diesel generators in domestic nuclear power plants

    International Nuclear Information System (INIS)

    Kim, Young Ho; Jung, Hyun Jong; Choi, Kwang Hee; Hong, Seoung Yeul

    2001-01-01

    Surveillance tests of Emergency Diesel Generators (EDGs) in Nuclear Power Plants (NPPs) have been conducted periodically to verify the reliability and integrity of the EDGs, however, it was found that these surveillance methods were so conservative and severe as to accelerate the degradation of the EDGs. Hence, new regulatory guideline, Reg. Guide 1.9 Rev. 3, was established by the U.S. NRC to resolve these problems. But it requires the additional implementation of reliability program of the EDGs to improve the actual reliability of them. In Korea, the EDGs of Yonggwang nuclear units 3 and 4 were the first plant applying new Reg. guide 1.9 rev.3 and implementing EDG reliability program. Furthermore it is expected that new guideline for the EDGs will be applied to other EDGs of Korean NPPs. In this paper, this reliability program is described, and it can be used as a reference for other EDGs in Korean NPPs

  3. Flash Memory Reliability: Read, Program, and Erase Latency Versus Endurance Cycling

    Science.gov (United States)

    Heidecker, Jason

    2010-01-01

    This report documents the efforts and results of the fiscal year (FY) 2010 NASA Electronic Parts and Packaging Program (NEPP) task for nonvolatile memory (NVM) reliability. This year's focus was to measure latency (read, program, and erase) of NAND Flash memories and determine how these parameters drift with erase/program/read endurance cycling.

  4. Using standardized video cases for assessment of medical communication skills: reliability of an objective structured video examination by computer

    NARCIS (Netherlands)

    Hulsman, R. L.; Mollema, E. D.; Oort, F. J.; Hoos, A. M.; de Haes, J. C. J. M.

    2006-01-01

    OBJECTIVE: Using standardized video cases in a computerized objective structured video examination (OSVE) aims to measure cognitive scripts underlying overt communication behavior by questions on knowledge, understanding and performance. In this study the reliability of the OSVE assessment is

  5. Intraobserver and intermethod reliability for using two different computer programs in preoperative lower limb alignment analysis

    Directory of Open Access Journals (Sweden)

    Mohamed Kenawey

    2016-12-01

    Conclusion: Computer assisted lower limb alignment analysis is reliable whether using graphics editing program or specialized planning software. However slight higher variability for angles away from the knee joint can be expected.

  6. Proposal of programming standards for a computerized protection system

    International Nuclear Information System (INIS)

    Ehrenberger, W.; Voges, U.

    1975-05-01

    In process computer systems with high safety and reliability requirements, correctness of the software has to be proved. During the development of a program specific guidelines should be met in order to facilitate the verification of its correctness. This paper is a collection of relevant proposals. (orig.) [de

  7. Reliability and reproducibility of subaxial cervical injury description system: a standardized nomenclature schema.

    Science.gov (United States)

    Bono, Christopher M; Schoenfeld, Andrew; Gupta, Giri; Harrop, James S; Anderson, Paul; Patel, Alpesh A; Dimar, John; Aarabi, Bizhan; Dailey, Andrew; Vaccaro, Alexander R; Gahr, Ralf; Shaffrey, Christopher; Anderson, David G; Rampersaud, Raj

    2011-08-01

    Radiographic measurement study. To develop a standardized cervical injury nomenclature system to facilitate description, communication, and classification among health care providers. The reliability and reproducibility of this system was then examined. Description of subaxial cervical injuries is critical for treatment decision making and comparing scientific reports of outcomes. Despite a number of available classification systems, surgeons, and researchers continue to use descriptive nomenclature, such as "burst" and "teardrop" fractures, to describe injuries. However, there is considerable inconsistency with use of such terms in the literature. Eleven distinct injury types and associated definitions were established for the subaxial cervical spine and subsequently refined by members of the Spine Trauma Study Group. A series of 18 cases of patients with a broad spectrum of subaxial cervical spine injuries was prepared and distributed to surgeon raters. Each rater was provided with the full nomenclature document and asked to select primary and secondary injury types for each case. After receipt of the raters' first round of classifications, the cases were resorted and returned to the raters for a second round of review. Interrater and intrarater reliabilities were calculated as percent agreement and Cohen kappa (κ) values. Intrarater reliability was assessed by comparing a given rater's diagnosis from the first and second rounds. Nineteen surgeons completed the first and second rounds of the study. Overall, the system demonstrated 56.4% interrater agreement and 72.8% intrarater agreement. Overall, interrater κ values demonstrated moderate agreement while intrarater κ values showed substantial agreement. Analyzed by injury types, only four (burst fractures, lateral mass fractures, flexion teardrop fractures, and anterior distraction injuries) demonstrated greater than 50% interrater agreement. This study demonstrated that, even in ideal circumstances, there is

  8. Shoulder muscle endurance: the development of a standardized and reliable protocol

    Directory of Open Access Journals (Sweden)

    Roy Jean-Sébastien

    2011-01-01

    Full Text Available Abstract Background Shoulder muscle fatigue has been proposed as a possible link to explain the association between repetitive arm use and the development of rotator cuff disorders. To our knowledge, no standardized clinical endurance protocol has been developed to evaluate the effects of muscle fatigue on shoulder function. Such a test could improve clinical examination of individuals with shoulder disorders. Therefore, the purpose of this study was to establish a reliable protocol for objective assessment of shoulder muscle endurance. Methods An endurance protocol was developed on a stationary dynamometer (Biodex System 3. The endurance protocol was performed in isotonic mode with the resistance set at 50% of each subject's peak torque as measured for shoulder external (ER and internal rotation (IR. Each subject performed 60 continuous repetitions of IR/ER rotation. The endurance protocol was performed by 36 healthy individuals on two separate occasions at least two days apart. Maximal isometric shoulder strength tests were performed before and after the fatigue protocol to evaluate the effects of the endurance protocol and its reliability. Paired t-tests were used to evaluate the reduction in shoulder strength due to the protocol, while intraclass correlation coefficients (ICC and minimal detectable change (MDC were used to evaluate its reliability. Results Maximal isometric strength was significantly decreased after the endurance protocol (P 0.84. Conclusions Changes in muscular performance observed during and after the muscular endurance protocol suggests that the protocol did result in muscular fatigue. Furthermore, this study established that the resultant effects of fatigue of the proposed isotonic protocol were reproducible over time. The protocol was performed without difficulty by all volunteers and took less than 10 minutes to perform, suggesting that it might be feasible for clinical practice. This protocol could be used to induce

  9. DOE standard: The Department of Energy Laboratory Accreditation Program administration

    International Nuclear Information System (INIS)

    1998-12-01

    This technical standard describes the US Department of Energy Laboratory Accreditation Program (DOELAP), organizational responsibilities, and the accreditation process. DOELAP evaluates and accredits personnel dosimetry and radiobioassay programs used for worker monitoring and protection at DOE and DOE contractor sites and facilities as required in Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection. The purpose of this technical standard is to establish procedures for administering DOELAP and acquiring accreditation

  10. IEEE standard requirements for reliability analysis in the design and operation of safety systems for nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    The purpose of this standard is to provide uniform, minimum acceptable requirements for the performance of reliability analyses for safety-related systems found in nuclear-power generating stations, but not to define the need for an analysis. The need for reliability analysis has been identified in other standards which expand the requirements of regulations (e.g., IEEE Std 379-1972 (ANSI N41.2-1972), ''Guide for the Application of the Single-Failure Criterion to Nuclear Power Generating Station Protection System,'' which describes the application of the single-failure criterion). IEEE Std 352-1975, ''Guide for General Principles of Reliability Analysis of Nuclear Power Generating Station Protection Systems,'' provides guidance in the application and use of reliability techniques referred to in this standard

  11. Comparison of Size Modulation Standard Automated Perimetry and Conventional Standard Automated Perimetry with a 10-2 Test Program in Glaucoma Patients.

    Science.gov (United States)

    Hirasawa, Kazunori; Takahashi, Natsumi; Satou, Tsukasa; Kasahara, Masayuki; Matsumura, Kazuhiro; Shoji, Nobuyuki

    2017-08-01

    This prospective observational study compared the performance of size modulation standard automated perimetry with the Octopus 600 10-2 test program, with stimulus size modulation during testing, based on stimulus intensity and conventional standard automated perimetry, with that of the Humphrey 10-2 test program in glaucoma patients. Eighty-seven eyes of 87 glaucoma patients underwent size modulation standard automated perimetry with Dynamic strategy and conventional standard automated perimetry using the SITA standard strategy. The main outcome measures were global indices, point-wise threshold, visual defect size and depth, reliability indices, and test duration; these were compared between size modulation standard automated perimetry and conventional standard automated perimetry. Global indices and point-wise threshold values between size modulation standard automated perimetry and conventional standard automated perimetry were moderately to strongly correlated (p 33.40, p modulation standard automated perimetry than with conventional standard automated perimetry, but the visual-field defect size was smaller (p modulation-standard automated perimetry than on conventional standard automated perimetry. The reliability indices, particularly the false-negative response, of size modulation standard automated perimetry were worse than those of conventional standard automated perimetry (p modulation standard automated perimetry than with conventional standard automated perimetry (p = 0.02). Global indices and the point-wise threshold value of the two testing modalities correlated well. However, the potential of a large stimulus presented at an area with a decreased sensitivity with size modulation standard automated perimetry could underestimate the actual threshold in the 10-2 test protocol, as compared with conventional standard automated perimetry.

  12. Microgrid Reliability Modeling and Battery Scheduling Using Stochastic Linear Programming

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Goncalo; Stadler, Michael; Siddiqui, Afzal; Marnay, Chris; DeForest, Nicholas; Barbosa-Povoa, Ana; Ferrao, Paulo

    2013-05-23

    This paper describes the introduction of stochastic linear programming into Operations DER-CAM, a tool used to obtain optimal operating schedules for a given microgrid under local economic and environmental conditions. This application follows previous work on optimal scheduling of a lithium-iron-phosphate battery given the output uncertainty of a 1 MW molten carbonate fuel cell. Both are in the Santa Rita Jail microgrid, located in Dublin, California. This fuel cell has proven unreliable, partially justifying the consideration of storage options. Several stochastic DER-CAM runs are executed to compare different scenarios to values obtained by a deterministic approach. Results indicate that using a stochastic approach provides a conservative yet more lucrative battery schedule. Lower expected energy bills result, given fuel cell outages, in potential savings exceeding 6percent.

  13. Reliability of the k{sub 0}-standardization method using geological sample analysed in a proficiency test

    Energy Technology Data Exchange (ETDEWEB)

    Pelaes, Ana Clara O.; Menezes, Maria Ângela de B.C., E-mail: anacpelaes@gmail.com, E-mail: menezes@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-11-01

    The Neutron Activation Analysis (NAA) is an analytical technique to determine the elemental chemical composition in samples of several matrices, that has been applied by the Laboratory for Neutron Activation Analysis, located at Centro de Desenvolvimento da Tecnologia Nuclear /Comissão Nacional de Energia Nuclear (Nuclear Technology Development Center/Brazilian Commission for Nuclear Energy), CDTN/CNEN, since the starting up of the TRIGA MARK I IPR-R1 reactor, in 1960. Among the methods of application of the technique, the k{sub 0}-standardization method, which was established at CDTN in 1995, is the most efficient and in 2003 it was reestablished and optimized. In order to verify the reproducibility of the results generated by the application of the k{sub 0}-standardization method at CDTN, aliquots of a geological sample sent by WEPAL (Wageningen Evaluating Programs for Analytical Laboratories) were analysed and its results were compared with the results obtained through the Intercomparison of Results organized by the International Atomic Energy Agency in 2015. WEPAL is an accredited institution for the organisation of interlaboratory studies, preparing and organizing proficiency testing schemes all over the world. Therefore, the comparison with the results provided aims to contribute to the continuous improvement of the quality of the results obtained by the CDTN. The objective of this study was to verify the reliability of the method applied two years after the intercomparison round. (author)

  14. Development of a Reliability Program approach to assuring operational nuclear safety

    International Nuclear Information System (INIS)

    Mueller, C.J.; Bezella, W.A.

    1985-01-01

    A Reliability Program (RP) model based on proven reliability techniques used in other high technology industries is being formulated for potential application in the nuclear power industry. Research findings are discussed. The reliability methods employed under NASA and military direction, commercial airline and related FAA programs were surveyed with several reliability concepts (e.g., quantitative reliability goals, reliability centered maintenance) appearing to be directly transferable. Other tasks in the RP development effort involved the benchmarking and evaluation of the existing nuclear regulations and practices relevant to safety/reliability integration. A review of current risk-dominant issues was also conducted using results from existing probabilistic risk assessment studies. The ongoing RP development tasks have concentrated on defining a RP for the operating phase of a nuclear plant's lifecycle. The RP approach incorporates safety systems risk/reliability analysis and performance monitoring activities with dedicated tasks that integrate these activities with operating, surveillance, and maintenance of the plant. The detection, root-cause evaluation and before-the-fact correction of incipient or actual systems failures as a mechanism for maintaining plant safety is a major objective of the RP

  15. Reliability and safety program plan outline for the operational phase of a waste isolation facility

    International Nuclear Information System (INIS)

    Ammer, H.G.; Wood, D.E.

    1977-01-01

    A Reliability and Safety Program plan outline has been prepared for the operational phase of a Waste Isolation Facility. The program includes major functions of risk assessment, technical support activities, quality assurance, operational safety, configuration monitoring, reliability analysis and support and coordination meetings. Detailed activity or task descriptions are included for each function. Activities are time-phased and presented in the PERT format for scheduling and interactions. Task descriptions include manloading, travel, and computer time estimates to provide data for future costing. The program outlined here will be used to provide guidance from a reliability and safety standpoint to design, procurement, construction, and operation of repositories for nuclear waste. These repositories are to be constructed under the National Waste Terminal Storage program under the direction of the Office of Waste Isolation, Union Carbide Corp. Nuclear Division

  16. Suncor maintenance and reliability

    Energy Technology Data Exchange (ETDEWEB)

    Little, S. [Suncor Energy, Calgary, AB (Canada)

    2006-07-01

    Fleet maintenance and reliability at Suncor Energy was discussed in this presentation, with reference to Suncor Energy's primary and support equipment fleets. This paper also discussed Suncor Energy's maintenance and reliability standard involving people, processes and technology. An organizational maturity chart that graphed organizational learning against organizational performance was illustrated. The presentation also reviewed the maintenance and reliability framework; maintenance reliability model; the process overview of the maintenance and reliability standard; a process flow chart of maintenance strategies and programs; and an asset reliability improvement process flow chart. An example of an improvement initiative was included, with reference to a shovel reliability review; a dipper trip reliability investigation; bucket related failures by type and frequency; root cause analysis of the reliability process; and additional actions taken. Last, the presentation provided a graph of the results of the improvement initiative and presented the key lessons learned. tabs., figs.

  17. SRS ES ampersand H standards compliance program management plan

    International Nuclear Information System (INIS)

    Hearn, W.H.

    1993-01-01

    On March 8, 1990, the Defense Nuclear Facilities Safety Board (DNFSB) issued Recommendation 90-2 to the Secretary of Energy. This recommendation, based upon the DNFSB's initial review and evaluation of the content and implementation of standards relating to the design, construction, operations, and decommissioning of defense nuclear facilities of the Department of Energy (DOE), called for three actions: (1) identification of specific standards that apply to design, construction, operation and decommissioning of DOE facilities; (2) assessment of the adequacy of those standards for protecting public health and safety; and (3) determination of the extent to which they have and are being implemented. This document defines the elements of the SRS program required to support the HQ program in response to DNFSB Recommendation 90-2. The objective is to ensure a consistent approach for all sitewide ES and H Standards Compliance Program efforts that satisfied the intent of Recommendation 90-2 and the HQ 90-2 Implementation Plan in a cost-effective manner. The methodology and instructions for implementation of the SRS program are contained in the Standards Compliance Program Implementation Plan. The Management Plan shall be used in conjunction with the Implementation Plan

  18. Implementation and Sustainability of the Russian Federation Ministry of Defense Nuclear Personnel Reliability Program

    International Nuclear Information System (INIS)

    Lata, Vasiliy; Coates, Cameron W.

    2010-01-01

    Through a cooperative effort between the US Department of Energy and the Russian Federation (RF) Ministry of Defense (MOD) a Personnel Reliability Program (PRP) for the nuclear handlers within the RF MOD is at the stage of implementation. Sustaining the program is of major significance for long term success. This paper will discuss the elements of the RF PRP and the equipment needs for implementation. Program requirements, documentation needs, training, and assurances of appropriate equipment use will be addressed.

  19. A study of science leadership and science standards in exemplary standards-based science programs

    Science.gov (United States)

    Carpenter, Wendy Renae

    The purpose for conducting this qualitative study was to explore best practices of exemplary standards-based science programs and instructional leadership practices in a charter high school and in a traditional high school. The focus of this study included how twelve participants aligned practices to National Science Education Standards to describe their science programs and science instructional practices. This study used a multi-site case study qualitative design. Data were obtained through a review of literature, interviews, observations, review of educational documents, and researcher's notes collected in a field log. The methodology used was a multi-site case study because of the potential, through cross analysis, for providing greater explanation of the findings in the study (Merriam, 1988). This study discovered six characteristics about the two high school's science programs that enhance the literature found in the National Science Education Standards; (a) Culture of expectations for learning-In exemplary science programs teachers are familiar with a wide range of curricula. They have the ability to examine critically and select activities to use with their students to promote the understanding of science; (b) Culture of varied experiences-In exemplary science programs students are provided different paths to learning, which help students, take in information and make sense of concepts and skills that are set forth by the standards; (c) Culture of continuous feedback-In exemplary science programs teachers and students work together to engage students in ongoing assessments of their work and that of others as prescribed in the standards; (d) Culture of Observations-In exemplary science programs students, teachers, and principals reflect on classroom instructional practices; teachers receive ongoing evaluations about their teaching and apply feedback towards improving practices as outlined in the standards; (e) Culture of continuous learning-In exemplary

  20. Relationship between internal medicine program board examination pass rates, accreditation standards, and program size.

    Science.gov (United States)

    Falcone, John L; Gonzalo, Jed D

    2014-01-19

    To determine Internal Medicine residency program compliance with the Accreditation Council for Graduate Medical Education 80% pass-rate standard and the correlation between residency program size and performance on the American Board of Internal Medicine Certifying Examination. Using a cross-sectional study design from 2010-2012 American Board of Internal Medicine Certifying Examination data of all Internal Medicine residency pro-grams, comparisons were made between program pass rates to the Accreditation Council for Graduate Medical Education pass-rate standard. To assess the correlation between program size and performance, a Spearman's rho was calculated. To evaluate program size and its relationship to the pass-rate standard, receiver operative characteristic curves were calculated. Of 372 Internal Medicine residency programs, 276 programs (74%) achieved a pass rate of =80%, surpassing the Accreditation Council for Graduate Medical Education minimum standard. A weak correlation was found between residency program size and pass rate for the three-year period (p=0.19, pInternal Medicine residency programs complied with Accreditation Council for Graduate Medical Education pass-rate standards, a quarter of the programs failed to meet this requirement. Program size is positively but weakly associated with American Board of Internal Medicine Certifying Examination performance, suggesting other unidentified variables significantly contribute to program performance.

  1. Comparative reliability of structured versus unstructured interviews in the admission process of a residency program.

    Science.gov (United States)

    Blouin, Danielle; Day, Andrew G; Pavlov, Andrey

    2011-12-01

    Although never directly compared, structured interviews are reported as being more reliable than unstructured interviews. This study compared the reliability of both types of interview when applied to a common pool of applicants for positions in an emergency medicine residency program. In 2008, one structured interview was added to the two unstructured interviews traditionally used in our resident selection process. A formal job analysis using the critical incident technique guided the development of the structured interview tool. This tool consisted of 7 scenarios assessing 4 of the domains deemed essential for success as a resident in this program. The traditional interview tool assessed 5 general criteria. In addition to these criteria, the unstructured panel members were asked to rate each candidate on the same 4 essential domains rated by the structured panel members. All 3 panels interviewed all candidates. Main outcomes were the overall, interitem, and interrater reliabilities, the correlations between interview panels, and the dimensionality of each interview tool. Thirty candidates were interviewed. The overall reliability reached 0.43 for the structured interview, and 0.81 and 0.71 for the unstructured interviews. Analyses of the variance components showed a high interrater, low interitem reliability for the structured interview, and a high interrater, high interitem reliability for the unstructured interviews. The summary measures from the 2 unstructured interviews were significantly correlated, but neither was correlated with the structured interview. Only the structured interview was multidimensional. A structured interview did not yield a higher overall reliability than both unstructured interviews. The lower reliability is explained by a lower interitem reliability, which in turn is due to the multidimensionality of the interview tool. Both unstructured panels consistently rated a single dimension, even when prompted to assess the 4 specific domains

  2. Performance, compliance and reliability of Waste stabilization pond: Effluent discharge quality and environmental protection agency standards in Ghana

    DEFF Research Database (Denmark)

    Owusu-Ansah, Emmanuel de-Graft Johnson; Sampson, Angelina; Amponsah, Samuel K.

    2015-01-01

    function to establish the relationship between the statistical coefficient of variation and the coefficient of reliability based on rth moment about the origin in the moment of generation function to generate the functions of the mean and standard deviation, properties of the standard Z normal distribution...... were used to establish the coefficient of reliability relationship depending on the coefficient of variation influenced by the standard of deviation. Discharge values of Physico-chemical Parameters measured from the WSP were found be performing acceptably based on the EPA standards, whereas only four......Measuring performance has been arguerably, one of the metric with many facets with different school of thoughts, as there exist different approaches of measuring it. Several of the existing approaches measure such metric by comparison with standards esherined in policy documents and as a result...

  3. Reliability study: digital engineered safety feature actuation system of Korean Standard Nuclear Power Plant

    International Nuclear Information System (INIS)

    Sudarno; Kang, H. G.; Jang, S. C.; Eom, H. S.; Ha, J. J.

    2003-04-01

    The usage of digital Instrumentation and Control (I and C) in a nuclear power plant becomes more extensive, including safety related systems. The PSA application of these new designs are very important in order to evaluate their reliability. In particular, Korean Standard Nuclear Power Plants (KSNPPs), typically Ulchin 5 and 6 (UCN 5 and 6) reactor units, adopted the digital safety-critical systems such as Digital Plant Protection System (DPPS) and Digital Engineered Safety Feature Actuation System (DESFAS). In this research, we developed fault tree models for assessing the unavailability of the DESFAS functions. We also performed an analysis of the quantification results. The unavailability results of different DESFAS functions showed that their values are comprised from 5.461E-5 to 3.14E-4. The system unavailability of DESFAS AFAS-1 is estimated as 5.461E-5, which is about 27% less than that of analog system if we consider the difference of human failure probability estimation between both analyses. The results of this study could be utilized in risk-effect analysis of KSNPP. We expect that the safety analysis result will contribute to design feedback

  4. Assessing the reliability of the borderline regression method as a standard setting procedure for objective structured clinical examination

    Directory of Open Access Journals (Sweden)

    Sara Mortaz Hejri

    2013-01-01

    Full Text Available Background: One of the methods used for standard setting is the borderline regression method (BRM. This study aims to assess the reliability of BRM when the pass-fail standard in an objective structured clinical examination (OSCE was calculated by averaging the BRM standards obtained for each station separately. Materials and Methods: In nine stations of the OSCE with direct observation the examiners gave each student a checklist score and a global score. Using a linear regression model for each station, we calculated the checklist score cut-off on the regression equation for the global scale cut-off set at 2. The OSCE pass-fail standard was defined as the average of all station′s standard. To determine the reliability, the root mean square error (RMSE was calculated. The R2 coefficient and the inter-grade discrimination were calculated to assess the quality of OSCE. Results: The mean total test score was 60.78. The OSCE pass-fail standard and its RMSE were 47.37 and 0.55, respectively. The R2 coefficients ranged from 0.44 to 0.79. The inter-grade discrimination score varied greatly among stations. Conclusion: The RMSE of the standard was very small indicating that BRM is a reliable method of setting standard for OSCE, which has the advantage of providing data for quality assurance.

  5. Standard Review Plan Maintenance Program implementing procedures document

    International Nuclear Information System (INIS)

    1996-11-01

    The implementing Procedures Document (IPD) was developed by the Inspection Program Projects Branch, Office of Nuclear Reactor Regulation, with assistance from Pacific Northwest National Laboratory, for the Standard Review Plan Maintenance Program (SRP-MP). The SRP-MP was established to maintain the Standard Review Plan (SRP) on an on-going basis. The IPD provides guidance, including an overall approach and procedures, for SRP-MP tasks. The objective of the IPD is to ensure that modifications to SRP need to reflect current NRC requirements and guidance are identified and that a consistent methodology is used to develop and revise SRP sections

  6. A method for developing standard patient education program

    DEFF Research Database (Denmark)

    Lura, Carolina Bryne; Hauch, Sophie Misser Pallesgaard; Gøeg, Kirstine Rosenbeck

    2018-01-01

    for developing standard digital patient education programs for patients in self-administration of blood samples drawn from CVC. The Design Science Research Paradigm was used to develop a digital patient education program, called PAVIOSY, to increase patient safety during execution of the blood sample collection...... of the educational patient system, health professionals must be engaged early in the development of content and design phase....

  7. Reliability of Pressure Ulcer Rates: How Precisely Can We Differentiate Among Hospital Units, and Does the Standard Signal‐Noise Reliability Measure Reflect This Precision?

    Science.gov (United States)

    Cramer, Emily

    2016-01-01

    Abstract Hospital performance reports often include rankings of unit pressure ulcer rates. Differentiating among units on the basis of quality requires reliable measurement. Our objectives were to describe and apply methods for assessing reliability of hospital‐acquired pressure ulcer rates and evaluate a standard signal‐noise reliability measure as an indicator of precision of differentiation among units. Quarterly pressure ulcer data from 8,199 critical care, step‐down, medical, surgical, and medical‐surgical nursing units from 1,299 US hospitals were analyzed. Using beta‐binomial models, we estimated between‐unit variability (signal) and within‐unit variability (noise) in annual unit pressure ulcer rates. Signal‐noise reliability was computed as the ratio of between‐unit variability to the total of between‐ and within‐unit variability. To assess precision of differentiation among units based on ranked pressure ulcer rates, we simulated data to estimate the probabilities of a unit's observed pressure ulcer rate rank in a given sample falling within five and ten percentiles of its true rank, and the probabilities of units with ulcer rates in the highest quartile and highest decile being identified as such. We assessed the signal‐noise measure as an indicator of differentiation precision by computing its correlations with these probabilities. Pressure ulcer rates based on a single year of quarterly or weekly prevalence surveys were too susceptible to noise to allow for precise differentiation among units, and signal‐noise reliability was a poor indicator of precision of differentiation. To ensure precise differentiation on the basis of true differences, alternative methods of assessing reliability should be applied to measures purported to differentiate among providers or units based on quality. © 2016 The Authors. Research in Nursing & Health published by Wiley Periodicals, Inc. PMID:27223598

  8. The INEL Human Reliability Program: The first two years of experience

    International Nuclear Information System (INIS)

    Minner, D.E.

    1986-01-01

    This paper provides a review of the design, implementation, and operation of the INEL Human Reliability Program from January 1984 through June of 1986. Human Reliability Programs are defined in terms of the ''insider threat'' to security of nuclear facilities. The design of HRP's are discussed with special attention given the special challenge of the disgruntled employee. Each component of an HRP is reviewed noting pitfalls and opportunities with each: drug testing of applicants and incumbents, psychological evaluation by management, security clearance procedures and administration including the use of an Employee Review Board to recommend action prior to final management decision

  9. Reliability database development for use with an object-oriented fault tree evaluation program

    Science.gov (United States)

    Heger, A. Sharif; Harringtton, Robert J.; Koen, Billy V.; Patterson-Hine, F. Ann

    1989-01-01

    A description is given of the development of a fault-tree analysis method using object-oriented programming. In addition, the authors discuss the programs that have been developed or are under development to connect a fault-tree analysis routine to a reliability database. To assess the performance of the routines, a relational database simulating one of the nuclear power industry databases has been constructed. For a realistic assessment of the results of this project, the use of one of existing nuclear power reliability databases is planned.

  10. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Version 5.0: Data loading manual. Volume 10

    International Nuclear Information System (INIS)

    VanHorn, R.L.; Wolfram, L.M.; Fowler, R.D.; Beck, S.T.; Smith, C.L.

    1995-04-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) suite of programs can be used to organize and standardize in an electronic format information from probabilistic risk assessments or individual plant examinations. The Models and Results Database (MAR-D) program of the SAPHIRE suite serves as the repository for probabilistic risk assessment and individual plant examination data and information. This report demonstrates by examples the common electronic and manual methods used to load these types of data. It is not a stand alone document but references documents that contribute information relative to the data loading process. This document provides a more detailed discussion and instructions for using SAPHIRE 5.0 only when enough information on a specific topic is not provided by another available source

  11. Cultural Adaptation and Reliability of the Compliance with Standard Precautions Scale (CSPS) for Nurses in Brazil.

    Science.gov (United States)

    Pereira, Fernanda Maria Vieira; Lam, Simon Ching; Gir, Elucir

    2017-03-02

    this study aimed to carry of the cultural adaptation and to evaluate the reliability of the Compliance with Standard Precautions Scale (CSPS) for nurses in Brazil. the adaptation process entailed translation, consensus among judges, back-translation, semantic validation and pretest. The reliability was evaluated by internal consistency (Cronbach alpha) and stability (test-retest). The instrument was administered to a sample group of 300 nurses who worked in a large hospital located in the city of São Paulo/SP, Brazil. through the semantic validation, the items from the scale were considered understandable and deemed important for the nurse´s clinical practice. The CSPS Brazilian Portuguese version (CSPS-PB) revealed excellent interpretability. The Cronbach`s alpha was 0.61 and the intraclass correlation coefficient was 0.85. the initial study showed that CSPS-PB is appropriate to assess compliance with standard precautions among nurses in Brazil. The reliability was considered acceptable. Furhter study is necessary to evaluate its comprehensive psychometric properties. adaptar culturalmente y evaluar la confiabilidad de la Compliance with Standard Precautions Scale (CSPS) para enfermeros en Brasil. el proceso de adaptación abarcó la traducción, consenso entre jueces, retrotraducción, validación semántica y pretest. La confiabilidad fue evaluada mediante la consistencia interna (alfa de Cronbach) y estabilidad (test-retest). El instrumento fue administrado a una muestra de 300 enfermeros actuantes en un gran hospital ubicado en la ciudad de São Paulo/SP, Brasil. a través de la validación semántica, los ítems de la escala fueron considerados comprensibles e importantes para la práctica clínica enfermera. La versión en portugués de Brasil de la CSPS (CSPS-PB) reveló excelente posibilidad de interpretación. El alfa de Cronbach correspondió a 0.61 y el coeficiente de correlación intraclase fue 0.85. el estudio inicial mostró que la CSPS-PB es

  12. SAPHIRE6.64, System Analysis Programs for Hands-on Integrated Reliability

    International Nuclear Information System (INIS)

    2001-01-01

    1 - Description of program or function: SAPHIRE is a collection of programs developed for the purpose of performing those functions necessary to create and analyze a complete Probabilistic Risk Assessment (PRA) primarily for nuclear power plants. The programs included in this suite are the Integrated Reliability and Risk Analysis System (IRRAS), the System Analysis and Risk Assessment (SARA) system, the Models And Results Database (MAR-D) system, and the Fault tree, Event tree and P and ID (FEP) editors. Previously these programs were released as separate packages. These programs include functions to allow the user to create event trees and fault trees, to define accident sequences and basic event failure data, to solve system and accident sequence fault trees, to quantify cut sets, and to perform uncertainty analysis on the results. Also included in this program are features to allow the analyst to generate reports and displays that can be used to document the results of an analysis. Since this software is a very detailed technical tool, the user of this program should be familiar with PRA concepts and the methods used to perform these analyses. 2 - Methods: SAPHIRE is written in MODULA-2 and uses an integrated commercial graphics package to interactively construct and edit fault trees. The fault tree solving methods used are industry recognized top down algorithms. For quantification, the program uses standard methods to propagate the failure information through the generated cut sets. SAPHIRE includes a separate module called the Graphical Evaluation Module (GEM). GEM provides a highly specialized user interface with SAPHIRE which automates the process for evaluating operational events at commercial nuclear power plants. Using GEM an analyst can estimate the risk associated with operational events (that is, perform a Level 1, Level 2, and Level 3 analysis for operational events) in a very efficient and expeditious manner. This on-line reference guide will

  13. 41 CFR 101-26.501-2 - Standardized buying programs.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Standardized buying programs. 101-26.501-2 Section 101-26.501-2 Public Contracts and Property Management Federal Property Management Regulations System FEDERAL PROPERTY MANAGEMENT REGULATIONS SUPPLY AND PROCUREMENT 26-PROCUREMENT...

  14. How to Integrate International Financial Reporting Standards into Accounting Programs

    Science.gov (United States)

    Singer, Robert A.

    2012-01-01

    It is expected the SEC will require U.S. domestic companies to prepare and file their annual 10Ks in accordance with international financial reporting standards (IFRS) by 2016. Given the probability that the FASB-IASB convergence project (i.e., Norwalk Agreement) will continue subsequent to mandatory adoption, US accounting programs will be…

  15. Reliability of a structured interview for admission to an emergency medicine residency program.

    Science.gov (United States)

    Blouin, Danielle

    2010-10-01

    Interviews are most important in resident selection. Structured interviews are more reliable than unstructured ones. We sought to measure the interrater reliability of a newly designed structured interview during the selection process to an Emergency Medicine residency program. The critical incident technique was used to extract the desired dimensions of performance. The interview tool consisted of 7 clinical scenarios and 1 global rating. Three trained interviewers marked each candidate on all scenarios without discussing candidates' responses. Interitem consistency and estimates of variance were computed. Twenty-eight candidates were interviewed. The generalizability coefficient was 0.67. Removing the central tendency ratings increased the coefficient to 0.74. Coefficients of interitem consistency ranged from 0.64 to 0.74. The structured interview tool provided good although suboptimal interrater reliability. Increasing the number of scenarios improves reliability as does applying differential weights to the rating scale anchors. The latter would also facilitate the identification of those candidates with extreme ratings.

  16. A Standardized Rubric for Evaluating Webquest Design: Reliability Analysis of ZUNAL Webquest Design Rubric

    Science.gov (United States)

    Unal, Zafer; Bodur, Yasar; Unal, Aslihan

    2012-01-01

    Current literature provides many examples of rubrics that are used to evaluate the quality of web-quest designs. However, reliability of these rubrics has not yet been researched. This is the first study to fully characterize and assess the reliability of a webquest evaluation rubric. The ZUNAL rubric was created to utilize the strengths of the…

  17. EPRI (Electric Power Research Institute) operator reliability experiments program - Training implications

    International Nuclear Information System (INIS)

    Joksimovich, V.; Spurgin, A.J.; Orvis, D.D.; Moieni, P.; Worledge, D.H.

    1990-01-01

    The primary purpose of the EPRI Operator Reliability Experiments (ORE) Program is to collect data for use in reliability and safety studies of nuclear power plant operation to more realistically take credit for operator performance in preventing core damage. The two objectives for fulfilling this purpose are: (1) to obtain quantitative/qualitative performance data on operating crew responses in the control room for potential accident sequences by using plant simulators, and (2) to test the Human Cognitive Reliability (HCR) correlation. This paper briefly discusses the background to this program, data collection and analysis, the results and quantitative/qualitative insights stemming from phase one which might be of interest to simulator operators and trainers

  18. SRS ES and H Standards Compliance Program Implementation Plan

    International Nuclear Information System (INIS)

    Hearn, W.H.

    1993-01-01

    On March 8, 1990, the Defense Nuclear Facilities Safety Board (DNFSB) issued Recommendation 90-2 to the Secretary of Energy. This recommendation, based upon the DNFSB's initial review and evaluation of the content and implementation of standards relating to the design, construction, operations, and decommissioning of defense nuclear facilities of the U.S. Department of Energy (DOE), called for three actions: identification of specific standards that apply to design, construction, operation and decommissioning of DOE facilities; assessment of the adequacy of those standards for protecting public health and safety; and determination of the extent to which they have and are being implemented. The purpose of this Implementation Plan is to define the single program for all sitewide and facility 90-2 ES and H Standards Compliance efforts, which will satisfy the HQ Implementation Plan, avoid duplicate efforts, be as simple and achievable as possible, include cost-saving innovations, use a graded approach based on facility hazards and future needs of facilities, and support configuration control for facility requirements. The Defense Waste Processing Facility (DWPF) has been designated a pilot facility for the 90-2 program and has progressed with their facility program ahead of the site-level program. The DWPF, and other Government-Owned Contractor-Operated (GOCO) facilities that progress on an enhanced schedule, will serve as pilot facilities for the site-level program. The lessons learned with their requirement identifications, and their assessments of the adequacy of and their compliance with these requirements will be used to improve the efficiency of the site-level and subsequent programs

  19. 48 CFR 1852.246-70 - Mission Critical Space System Personnel Reliability Program.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Mission Critical Space... CONTRACT CLAUSES Texts of Provisions and Clauses 1852.246-70 Mission Critical Space System Personnel Reliability Program. As prescribed in 1846.370(a), insert the following clause: Mission Critical Space System...

  20. Intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom

    International Nuclear Information System (INIS)

    Lee, Song; Choi, Joon Il; Park, Michael Yong; Yeo, Dong Myung; Byun, Jae Young; Jung, Seung Eun; Rha, Sung Eun; Oh, Soon Nam; Lee, Young Joon

    2014-01-01

    To evaluate intra- and interobserver reliability of the gray scale/dynamic range of the phantom image evaluation of ultrasonography using a standardized phantom, and to assess the effect of interactive education on the reliability. Three radiologists (a resident, and two board-certified radiologists with 2 and 7 years of experience in evaluating ultrasound phantom images) performed the gray scale/dynamic range test for an ultrasound machine using a standardized phantom. They scored the number of visible cylindrical structures of varying degrees of brightness and made a pass or fail decision. First, they scored 49 phantom images twice from a 2010 survey with limited knowledge of phantom images. After this, the radiologists underwent two hours of interactive education for the phantom images and scored another 91 phantom images from a 2011 survey twice. Intra- and interobserver reliability before and after the interactive education session were analyzed using K analyses. Before education, the K-value for intraobserver reliability for the radiologist with 7 years of experience, 2 years of experience, and the resident was 0.386, 0.469, and 0.465, respectively. After education, the K-values were improved (0.823, 0.611, and 0.711, respectively). For interobserver reliability, the K-value was also better after the education for the 3 participants (0.067, 0.002, and 0.547 before education; 0.635, 0.667, and 0.616 after education, respectively). The intra- and interobserver reliability of the gray scale/dynamic range was fair to substantial. Interactive education can improve reliability. For more reliable results, double- checking of phantom images by multiple reviewers is recommended.

  1. reliability reliability

    African Journals Online (AJOL)

    eobe

    Corresponding author, Tel: +234-703. RELIABILITY .... V , , given by the code of practice. However, checks must .... an optimization procedure over the failure domain F corresponding .... of Concrete Members based on Utility Theory,. Technical ...

  2. Marketing Program Standardization: The Experience of TNCs in Poland

    Directory of Open Access Journals (Sweden)

    Mariusz Sagan

    2016-01-01

    Full Text Available The purpose of this study is to determine the rate of standardization of marketing programs in transnational corporations in the consumer goods market in Poland, which currently is one of the fastest growing markets in the world. An important research objective was to observe how Polish consumers adopt the marketing patterns and related lifestyles from countries of Western Europe and the USA. The empirical tests and data, collected in a sample survey of 35 transnational corporations and their 140 products, and using varied methods of statistical inference, allowed to formulate the following conclusions. The analyzed TNC’s adopted a clear standardization strategy in the Polish market. Among the analyzed products, 2/3 of them have been entirely transferred from foreign markets into the Polish market. A detailed analysis has indicated that the standardization rate of product and its items in the FMCG market in Poland is high and very high, and significantly higher than the pricing and advertising strategy standardization rates. The product standardization rate in the Polish market has been slightly higher than the rate in the developed countries, yet the pricing standardization has been significantly lower. The standardization of advertising strategies showed similar features.

  3. 77 FR 43190 - Regional Reliability Standard PRC-006-SERC-01-Automatic Underfrequency Load Shedding Requirements

    Science.gov (United States)

    2012-07-24

    ..., Oklahoma, Arkansas, Louisiana, Texas and Florida). The SERC Region is currently geographically divided into... Requirement itself and directed NERC to make that requirement explicit in future versions of the Reliability..., 888 First Street NE., [[Page 43195

  4. Substation design improvement with a probabilistic reliability approach using the TOPASE program

    Energy Technology Data Exchange (ETDEWEB)

    Bulot, M.; Heroin, G.; Bergerot, J-L.; Le Du, M. [Electricite de France (France)

    1997-12-31

    TOPASE, (the French acronym for Probabilistic Tools and Data Processing for the Analysis of Electric Systems), developed by Electricite de France (EDF) to perform reliability studies on transmission substations, was described. TOPASE serves a dual objective of assisting in the automation of HV substation studies, as well as enabling electrical systems experts who are not necessarily specialists in reliability studies to perform such studies. The program is capable of quantifying the occurrence rate of undesirable events and of identifying critical equipment and the main incident scenarios. The program can be used to improve an existing substation, to choose an HV structure during the design stage, or to choose a system of protective devices. Data collected during 1996 and 1997 will be analyzed to identify useful experiences and to validate the basic concepts of the program. 4 figs.

  5. Planning and implementation of reliability/quality programs to energy plants

    International Nuclear Information System (INIS)

    Quenon, J.

    1986-01-01

    Quality Assurance principles have long been applied in part to many varied industrial enterprises. The advent of commercial nuclear power brought the evolution of a more comprehensive approach to the applications of quality assurance programs in this industry. However, the application philosophy was almost totally aimed at assuring the safety of the worker and the public. Recently, there has been a strong movement by industries and business in the U.S. and Europe to apply quality assurance in a more general way to assure overall reliability as well as safety. This paper describes an approach to enable management to not only make initial determinations of how to apply the elements of a reliability/quality assurance program, but how to continuously adjust the program to optimize the benefits that can be obtained

  6. Analysis and recommendations for a reliable programming of software based safety systems

    International Nuclear Information System (INIS)

    Nunez McLeod, J.; Nunez McLeod, J.E.; Rivera, S.S.

    1997-01-01

    The present paper summarizes the results of several studies performed for the development of high software on i486 microprocessors, towards its utilization for control and safety systems for nuclear power plants. The work is based on software programmed in C language. Several recommendations oriented to high reliability software are analyzed, relating the requirements on high level language to its influence on assembler level. Several metrics are implemented, that allow for the quantification of the results achieved. New metrics were developed and other were adapted, in order to obtain more efficient indexes for the software description. Such metrics are helpful to visualize the adaptation of the software under development to the quality rules under use. A specific program developed to assist the reliability analyst on this quantification is also present in the paper. It performs the analysis of an executable program written in C language, disassembling it and evaluating its inter al structures. (author)

  7. Assessment of the reliability of standard automated perimetry in regions of glaucomatous damage.

    Science.gov (United States)

    Gardiner, Stuart K; Swanson, William H; Goren, Deborah; Mansberger, Steven L; Demirel, Shaban

    2014-07-01

    Visual field testing uses high-contrast stimuli in areas of severe visual field loss. However, retinal ganglion cells saturate with high-contrast stimuli, suggesting that the probability of detecting perimetric stimuli may not increase indefinitely as contrast increases. Driven by this concept, this study examines the lower limit of perimetric sensitivity for reliable testing by standard automated perimetry. Evaluation of a diagnostic test. A total of 34 participants with moderate to severe glaucoma; mean deviation at their last clinic visit averaged -10.90 dB (range, -20.94 to -3.38 dB). A total of 75 of the 136 locations tested had a perimetric sensitivity of ≤ 19 dB. Frequency-of-seeing curves were constructed at 4 nonadjacent visual field locations by the Method of Constant Stimuli (MOCS), using 35 stimulus presentations at each of 7 contrasts. Locations were chosen a priori and included at least 2 with glaucomatous damage but a sensitivity of ≥ 6 dB. Cumulative Gaussian curves were fit to the data, first assuming a 5% false-negative rate and subsequently allowing the asymptotic maximum response probability to be a free parameter. The strength of the relation (R(2)) between perimetric sensitivity (mean of last 2 clinic visits) and MOCS sensitivity (from the experiment) for all locations with perimetric sensitivity within ± 4 dB of each selected value, at 0.5 dB intervals. Bins centered at sensitivities ≥ 19 dB always had R(2) >0.1. All bins centered at sensitivities ≤ 15 dB had R(2) <0.1, an indication that sensitivities are unreliable. No consistent conclusions could be drawn between 15 and 19 dB. At 57 of the 81 locations with perimetric sensitivity <19 dB, including 49 of the 63 locations ≤ 15 dB, the fitted asymptotic maximum response probability was <80%, consistent with the hypothesis of response saturation. At 29 of these locations the asymptotic maximum was <50%, and so contrast sensitivity (50% response rate) is undefined. Clinical

  8. A Primer for DoD Reliability, Maintainability, Safety, and Logistics Standards, 1992

    Science.gov (United States)

    1991-10-01

    Application of Reliability-Centered Maintenance to Naval Aircraft Weapon Systems and Support Equipment "* FMD -91 Failure Mode/Mechanism...Distributions ( FMD -91) available from the Reliability Analysis Center, HIT Research Institute, 201 Mill St., Rome, NY 13440-8200. 14.4 PHYSICAL...Fault Tree Analysis ( FTA ) (9) Sneak Circuit Analysis (10) Design Reviews Items (1) and (2) are addressed in Section 7 largely by reference to MIL

  9. DOE standard: Filter test facility quality program plan

    International Nuclear Information System (INIS)

    1999-02-01

    This standard was developed primarily for application in US Department of Energy programs. It contains specific direction for HEPA filter testing performed at a DOE-accepted HEPA Filter Test Facility (FTF). Beneficial comments (recommendations, additions, deletions) and any pertinent data that may improve this document should be sent to the Office of Nuclear Safety Policy and Standards (EH-31), US Department of Energy, Washington, DC 20585, by letter or by using the self-addressed Document Improvement Proposal form (DOE F 1300.3) appearing at the end of this document

  10. Opinions of practitioners and program directors concerning accreditation standards for postdoctoral pediatric dentistry training programs.

    Science.gov (United States)

    Casamassimo, P S; Wilson, S

    1999-01-01

    This study was performed to assess opinions of program directors and practitioners about the importance and necessary numbers of experiences required by current accreditation standards for training of pediatric dentists. A 32-item questionnaire was sent to all program directors of ADA-accredited postdoctoral pediatric dentistry training programs and to a random sample of 10% of the fellow/active membership of the American Academy of Pediatric Dentistry. An overall response rate of 56% was obtained from the single mailing. Practitioners and program directors differed significantly (P dentistry: initiating and completing a research paper, biostatistics/epidemiology, and practice management. Program directors had little difficulty obtaining required experiences, and program dependence on Medicaid did not negatively affect quality of education. Practitioners and program directors agreed on the importance of most experiences and activities required by current accreditation standards.

  11. Development and Evaluation of a Training Program for Organ Procurement Coordinators Using Standardized Patient Methodology.

    Science.gov (United States)

    Odabasi, Orhan; Elcin, Melih; Uzun Basusta, Bilge; Gulkaya Anik, Esin; Aki, Tuncay F; Bozoklar, Ata

    2015-12-01

    The low rate of consent by next of kin of donor-eligible patients is a major limiting factor in organ transplant. Educating health care professionals about their role may lead to measurable improvements in the process. Our aim was to describe the developmental steps of a communication skills training program for health care professionals using standardized patients and to evaluate the results. We developed a rubric and 5 cases for standardized family interviews. The 20 participants interviewed standardized families at the beginning and at the end of the training course, with interviews followed by debriefing sessions. Participants also provided feedback before and after the course. The performance of each participant was assessed by his or her peers using the rubric. We calculated the generalizability coefficient to measure the reliability of the rubric and used the Wilcoxon signed rank test to compare achievement among participants. Statistical analyses were performed with SPSS software (SPSS: An IBM Company, version 17.0, IBM Corporation, Armonk, NY, USA). All participants received higher scores in their second interview, including novice participants who expressed great discomfort during their first interview. The participants rated the scenarios and the standardized patients as very representative of real-life situations, with feedback forms showing that the interviews, the video recording sessions, and the debriefing sessions contributed to their learning. Our program was designed to meet the current expectations and implications in the field of donor consent from next of kin. Results showed that our training program developed using standardized patient methodology was effective in obtaining the communication skills needed for family interviews during the consent process. The rubric developed during the study was a valid and reliable assessment tool that could be used in further educational activities. The participants showed significant improvements in

  12. Reliability and integrity management program for PBMR helium pressure boundary components - HTR2008-58036

    International Nuclear Information System (INIS)

    Fleming, K. N.; Gamble, R.; Gosselin, S.; Fletcher, J.; Broom, N.

    2008-01-01

    The purpose of this paper is to present the results of a study to establish strategies for the reliability and integrity management (RIM) of passive metallic components for the PBMR. The RIM strategies investigated include design elements, leak detection and testing approaches, and non-destructive examinations. Specific combinations of strategies are determined to be necessary and sufficient to achieve target reliability goals for passive components. This study recommends a basis for the RIM program for the PBMR Demonstration Power Plant (DPP) and provides guidance for the development by the American Society of Mechanical Engineers (ASME) of RIM requirements for Modular High Temperature Gas-Cooled Reactors (MHRs). (authors)

  13. Reliability of an Automated High-Resolution Manometry Analysis Program across Expert Users, Novice Users, and Speech-Language Pathologists

    Science.gov (United States)

    Jones, Corinne A.; Hoffman, Matthew R.; Geng, Zhixian; Abdelhalim, Suzan M.; Jiang, Jack J.; McCulloch, Timothy M.

    2014-01-01

    Purpose: The purpose of this study was to investigate inter- and intrarater reliability among expert users, novice users, and speech-language pathologists with a semiautomated high-resolution manometry analysis program. We hypothesized that all users would have high intrarater reliability and high interrater reliability. Method: Three expert…

  14. Education Technology Standards Self-Efficacy (ETSSE) Scale: A Validity and Reliability Study

    Science.gov (United States)

    Simsek, Omer; Yazar, Taha

    2016-01-01

    Problem Statement: The educational technology standards for teachers set by the International Society for Technology in Education (the ISTE Standards-T) represent an important framework for using technology effectively in teaching and learning processes. These standards are widely used by universities, educational institutions, and schools. The…

  15. A reference standard-based quality assurance program for radiology.

    Science.gov (United States)

    Liu, Patrick T; Johnson, C Daniel; Miranda, Rafael; Patel, Maitray D; Phillips, Carrie J

    2010-01-01

    The authors have developed a comprehensive radiology quality assurance (QA) program that evaluates radiology interpretations and procedures by comparing them with reference standards. Performance metrics are calculated and then compared with benchmarks or goals on the basis of published multicenter data and meta-analyses. Additional workload for physicians is kept to a minimum by having trained allied health staff members perform the comparisons of radiology reports with the reference standards. The performance metrics tracked by the QA program include the accuracy of CT colonography for detecting polyps, the false-negative rate for mammographic detection of breast cancer, the accuracy of CT angiography detection of coronary artery stenosis, the accuracy of meniscal tear detection on MRI, the accuracy of carotid artery stenosis detection on MR angiography, the accuracy of parathyroid adenoma detection by parathyroid scintigraphy, the success rate for obtaining cortical tissue on ultrasound-guided core biopsies of pelvic renal transplants, and the technical success rate for peripheral arterial angioplasty procedures. In contrast with peer-review programs, this reference standard-based QA program minimizes the possibilities of reviewer bias and erroneous second reviewer interpretations. The more objective assessment of performance afforded by the QA program will provide data that can easily be used for education and management conferences, research projects, and multicenter evaluations. Additionally, such performance data could be used by radiology departments to demonstrate their value over nonradiology competitors to referring clinicians, hospitals, patients, and third-party payers. Copyright 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. Genetic Programming and Standardization in Water Temperature Modelling

    Directory of Open Access Journals (Sweden)

    Maritza Arganis

    2009-01-01

    Full Text Available An application of Genetic Programming (an evolutionary computational tool without and with standardization data is presented with the aim of modeling the behavior of the water temperature in a river in terms of meteorological variables that are easily measured, to explore their explanatory power and to emphasize the utility of the standardization of variables in order to reduce the effect of those with large variance. Recorded data corresponding to the water temperature behavior at the Ebro River, Spain, are used as analysis case, showing a performance improvement on the developed model when data are standardized. This improvement is reflected in a reduction of the mean square error. Finally, the models obtained in this document were applied to estimate the water temperature in 2004, in order to provide evidence about their applicability to forecasting purposes.

  17. Environmental assessment for the Consumer Products Efficiency Standards program

    Energy Technology Data Exchange (ETDEWEB)

    1980-05-23

    The Energy Policy and Conservation Act of 1975 as amended by the National Energy Conservation Policy Act of 1978, requires the DOE to prescribe energy efficiency standards for thirteen consumer products. The Consumer Products Efficiency Standards (CPES) program covers the following products: refrigerators and refrigerator-freezers; freezers;clothes dryers;water heaters; room air conditioners; home heating equipment (not including furnaces); kitchen ranges and ovens; central air conditioners (cooling and heat pumps); furnaces; dishwashers; television sets; clothes washers; and humidifiers and dehumidifiers. DOE is proposing two sets of standards for all thirteen consumer products: intermediate standards to become effective in 1981 for the first nine products and in 1982 for the second four products, and final standards to become effective in 1986 and 1987, respectively. The final standards are more restrictive than the intermediate standards and will provide manufacturers with the maximum time permitted under the Act to plan and develop extensive new lines of efficient consumer products. The final standards proposed by DOE require the maximum improvements in efficiency which are technologically feasible and economically justified, as required by Section 325(c) of EPCA. The thirteen consumer products account for approximately 90% of all the energy consumed in the nation's residences, or more than 20% of the nation's energy needs. Increases in the energy efficiency of these consumer products can help to narrow the gap between the nation's increasing demand for energy and decreasing supplies of domestic oil and natural gas. Improvements in the efficiency of consumer products can thus help to solve the nation's energy crisis.

  18. Practical standard for nuclear power plant life management programs: 2007

    International Nuclear Information System (INIS)

    2006-03-01

    The standard specifies the method of implementing nuclear power plant life management programs. The plant life management programs evaluate the integrity of the plant structures, systems and components, assessing if appropriate measures are taken against existing aging phenomena, if there are possibilities of occurrence and development of aging phenomena and if a sufficient level of margin is maintained to assure the integrity throughout the future operating period. The programs also assess the validity of the current maintenance activities, such as trend monitoring, walkdowns, periodic tests and inspections, repair and replacement work for the purpose of preventive maintenance, and utilization of lessons learned from past trouble experience, in order to newly identify maintenance measures. The technical evaluation on aging phenomena is conducted to establish the 10 year maintenance program for nuclear power plants until the plant reaches 30 years of service. The standard was established and issued by the Atomic Energy Society of Japan (AESJ) through the discussion of experts in the associated fields. (T. Tanaka)

  19. Reliability of early radiographic evaluations for canine hip dysplasia obtained from the standard ventrodorsal radiographic projection

    International Nuclear Information System (INIS)

    Corley, E.A.; Keller, G.G.; Lattimer, J.C.; Ellersieck, M.R.

    1997-01-01

    To determine reliability of preliminary evaluations for canine hip dysplasia (CHD) performed by the Orthopedic Foundation for Animals on dogs between 3 and 18 months of age. Retrospective analysis of data from the Orthopedic Foundation for Animals database. 2,332 Golden Retrievers, Labrador Retrievers, German Shepherd Dogs, and Rottweilers for which preliminary evaluation had been performed between 3 and 18 months of age and for which results of a definitive evaluation performed after 24 months of age were available. Each radiograph was evaluated, and hip joint status was graded as excellent, good, fair, or borderline phenotype or mild, moderate, or severe dysplasia. Preliminary evaluations were performed by 1 radiologist; definitive evaluations were the consensus of 3 radiologists. Reliability of preliminary evaluations was calculated as the percentage of definitive evaluations (normal vs dysplastic) that were unchanged from preliminary evaluations. Reliability of a preliminary evaluation of normal hip joint phenotype decreased significantly as the preliminary evaluation changed from excellent (100%) to good (97.9%) to fair (76.9%) phenotype. Reliability of a preliminary evaluation of CHD increased significantly as the preliminary evaluation changed from mild (84.4%) to moderate (97.4%) CHD. Reliability of preliminary evaluations increased significantly as age at the time of preliminary evaluation increased, regardless of whether dogs received a preliminary evaluation of normal phenotype or CHD. Results suggest that preliminary evaluations of hip joint status in dogs are generally reliable. However, dogs that receive a preliminary evaluation of fair phenotype of mild CHD should be reevaluated after 24 months of age

  20. Phd study of reliability and validity: One step closer to a standardized music therapy assessment model

    DEFF Research Database (Denmark)

    Jacobsen, Stine Lindahl

    The paper will present a phd study concerning reliability and validity of music therapy assessment model “Assessment of Parenting Competences” (APC) in the area of families with emotionally neglected children. This study had a multiple strategy design with a philosophical base of critical realism...... and pragmatism. The fixed design for this study was a between and within groups design in testing the APCs reliability and validity. The two different groups were parents with neglected children and parents with non-neglected children. The flexible design had a multiple case study strategy specifically...

  1. Crisis Reliability Indicators Supporting Emergency Services (CRISES): A Framework for Developing Performance Measures for Behavioral Health Crisis and Psychiatric Emergency Programs.

    Science.gov (United States)

    Balfour, Margaret E; Tanner, Kathleen; Jurica, Paul J; Rhoads, Richard; Carson, Chris A

    2016-01-01

    Crisis and emergency psychiatric services are an integral part of the healthcare system, yet there are no standardized measures for programs providing these services. We developed the Crisis Reliability Indicators Supporting Emergency Services (CRISES) framework to create measures that inform internal performance improvement initiatives and allow comparison across programs. The framework consists of two components-the CRISES domains (timely, safe, accessible, least-restrictive, effective, consumer/family centered, and partnership) and the measures supporting each domain. The CRISES framework provides a foundation for development of standardized measures for the crisis field. This will become increasingly important as pay-for-performance initiatives expand with healthcare reform.

  2. Assessment of the Japanese Energy Efficiency Standards Program

    Directory of Open Access Journals (Sweden)

    Jun Arakawa

    2015-03-01

    Full Text Available Japanese energy efficiency standards program for appliances is a unique program which sets and revises mandatory standards based on the products of the highest energy efficiency on the markets. This study assessed the cost-effectiveness of the standard settings for air conditioner as a major residential appliance or typical example in the program. Based on analyses of empirical data, the net costs and effects from 1999 to 2040 were estimated. When applying a discount rate of 3%, the cost of abating CO2 emissions realized through the considered standards was estimated to be -13700 JPY/t-CO2. The sensitivity analysis, however, showed the cost turns into positive at a discount rate of 26% or higher. The authors also revealed that the standards’ “excellent” cost-effectiveness largely depends on that of the 1st standard setting, and the CO2 abatement cost through the 2nd standard was estimated to be as high as 26800 JPY/t-CO2. The results imply that the government is required to be careful about the possible economic burden imposed when considering introducing new, additional standards.

  3. An efficient particle swarm approach for mixed-integer programming in reliability-redundancy optimization applications

    International Nuclear Information System (INIS)

    Santos Coelho, Leandro dos

    2009-01-01

    The reliability-redundancy optimization problems can involve the selection of components with multiple choices and redundancy levels that produce maximum benefits, and are subject to the cost, weight, and volume constraints. Many classical mathematical methods have failed in handling nonconvexities and nonsmoothness in reliability-redundancy optimization problems. As an alternative to the classical optimization approaches, the meta-heuristics have been given much attention by many researchers due to their ability to find an almost global optimal solutions. One of these meta-heuristics is the particle swarm optimization (PSO). PSO is a population-based heuristic optimization technique inspired by social behavior of bird flocking and fish schooling. This paper presents an efficient PSO algorithm based on Gaussian distribution and chaotic sequence (PSO-GC) to solve the reliability-redundancy optimization problems. In this context, two examples in reliability-redundancy design problems are evaluated. Simulation results demonstrate that the proposed PSO-GC is a promising optimization technique. PSO-GC performs well for the two examples of mixed-integer programming in reliability-redundancy applications considered in this paper. The solutions obtained by the PSO-GC are better than the previously best-known solutions available in the recent literature

  4. An efficient particle swarm approach for mixed-integer programming in reliability-redundancy optimization applications

    Energy Technology Data Exchange (ETDEWEB)

    Santos Coelho, Leandro dos [Industrial and Systems Engineering Graduate Program, LAS/PPGEPS, Pontifical Catholic University of Parana, PUCPR, Imaculada Conceicao, 1155, 80215-901 Curitiba, Parana (Brazil)], E-mail: leandro.coelho@pucpr.br

    2009-04-15

    The reliability-redundancy optimization problems can involve the selection of components with multiple choices and redundancy levels that produce maximum benefits, and are subject to the cost, weight, and volume constraints. Many classical mathematical methods have failed in handling nonconvexities and nonsmoothness in reliability-redundancy optimization problems. As an alternative to the classical optimization approaches, the meta-heuristics have been given much attention by many researchers due to their ability to find an almost global optimal solutions. One of these meta-heuristics is the particle swarm optimization (PSO). PSO is a population-based heuristic optimization technique inspired by social behavior of bird flocking and fish schooling. This paper presents an efficient PSO algorithm based on Gaussian distribution and chaotic sequence (PSO-GC) to solve the reliability-redundancy optimization problems. In this context, two examples in reliability-redundancy design problems are evaluated. Simulation results demonstrate that the proposed PSO-GC is a promising optimization technique. PSO-GC performs well for the two examples of mixed-integer programming in reliability-redundancy applications considered in this paper. The solutions obtained by the PSO-GC are better than the previously best-known solutions available in the recent literature.

  5. A reliability program for emergency diesel generators at nuclear power plants: Maintenance, surveillance, and condition monitoring

    International Nuclear Information System (INIS)

    Lofgren, E.V.; Henderson, W.; Burghardt, D.; Kripps, L.; Rothleder, B.

    1988-12-01

    This report is a companion report on NUREG/CR-5078, Volume 1, ''A Reliability Program for Emergency Diesel Generators at Nuclear Power Plants: Program Structure.'' The purpose of this report is to provide technical findings and insights related to: failure evaluation, troubleshooting, maintenance, surveillance, and condition monitoring. Examples and recommendations are provided for each of these areas based on actual emergency diesel generator (EDG) operating experience and the opinions of diesel generator experts. This report expands the more general guidance provided in Volume 1. In addition, a discussion of EDG interactions with other plant systems (e.g., instrument, air, service water, dc power) is provided since experience has shown that these support systems and their operation can adversely affect EDG reliability. Portions of this report have been designed for use by onsite personnel for evaluating operational characteristics of EDGs. 5 refs., 8 figs., 7 tabs

  6. Indian program for development of technologies relevant to reliable, non-intrusive, concealed-contraband detection

    International Nuclear Information System (INIS)

    Auluck, S.K.H.

    2007-01-01

    Generating capability for reliable, non-intrusive detection of concealed-contraband, particularly, organic contraband like explosives and narcotics, has become a national priority. This capability spans a spectrum of technologies. If a technology mission addressing the needs of a highly sophisticated technology like PFNA is set up, the capabilities acquired would be adequate to meet the requirements of many other sets of technologies. This forms the background of the Indian program for development of technologies relevant to reliable, non-intrusive, concealed contraband detection. One of the central themes of the technology development programs would be modularization of the neutron source and detector technologies, so that common elements can be combined in different ways for meeting a variety of application requirements. (author)

  7. 77 FR 27574 - Automatic Underfrequency Load Shedding and Load Shedding Plans Reliability Standards

    Science.gov (United States)

    2012-05-11

    ....'' \\33\\ \\33\\ NERC Comments at 8. 45. EEI, MISO, and G&T Cooperatives support the timelines in Reliability... rushed. EEI, MISO, and G&T Cooperatives state that planning coordinators can complete analyses of less... G&T Cooperatives, assessments of complex events can be time and resource intensive. Thus, we agree...

  8. 75 FR 4375 - Transmission Loading Relief Reliability Standard and Curtailment Priorities

    Science.gov (United States)

    2010-01-27

    ... the curtailment priorities set forth in the Commission's pro forma open access transmission tariff... prevent or manage potential or actual system operating limit or interconnection reliability operating...). \\2\\ A System Operating Limit or SOL is the value (such as MW, MVar, amperes, frequency or volts) that...

  9. CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.

    Science.gov (United States)

    Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David

    2016-03-01

    Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC 2 ,: 1  = 0.59) over Bath-Thermode (ICC 2 ,: 1  = 0.34) or Two-Thermodes (ICC 2 ,: 1  = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC 2 ,: 1  = 0.76 vs ICC 2 ,: 1  = 0.16). Conditioned test-stimulus pain scores were of good (ICC 2 ,: 1  = 0.62) or fair (ICC 2 ,: 1  = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC 2 ,: 1  = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e

  10. Evaluating the reliability of uranium concentration and isotope ratio measurements via an interlaboratory comparison program

    International Nuclear Information System (INIS)

    Oliveira Junior, Olivio Pereira de; Oliveira, Inez Cristina de; Pereira, Marcia Regina; Tanabe, Eduardo

    2009-01-01

    The nuclear fuel cycle is a strategic area for the Brazilian development because it is associated with the generation of electricity needed to boost the country economy. Uranium is one the chemical elements in this cycle and its concentration and isotope composition must be accurately known. In this present work, the reliability of the uranium concentration and isotope ratio measurements carried out at the CTMSP analytical laboratories is evaluated by the results obtained in an international interlaboratory comparison program. (author)

  11. Applicability of the “Gallet equation” to the vegetation clearances of NERC Reliability Standard FAC-003-2

    Energy Technology Data Exchange (ETDEWEB)

    Kirkham, Harold

    2012-03-31

    NERC has proposed a standard to use to specify clearances between vegetation and power lines. The purpose of the rule is to reduce the probability of flashover to a calculably low level. This report was commissioned by FERC’s Office of Electrical Reliability. The scope of the study was analysis of the mathematics and documentation of the technical justification behind the application of the Gallet equation and the assumptions used in the technical reference paper

  12. The reliability and validity of the standardized Mensendieck test in relation to disability in patients with chronic pain.

    Science.gov (United States)

    Keessen, Paul; Maaskant, Jolanda; Visser, Bart

    2018-08-01

    The standardized Mensendieck test (SMT) was developed to quantify posture, movement, gait, and respiration. In the hands of an experienced therapist, the SMT is proven to be a reliable tool. It is unclear whether posture, movement, gait, and respiration are related to the degree of functional disability in patients with chronic pain. The objective of this study was to assess the reliability and convergent validity of the SMT in a heterogeneous sample of 50 patients with chronic pain. Internal consistency was determined by Cronbach's α and interrater reliability by the intraclass correlation coefficient (ICC). Convergent validity was assessed by determining the Spearman rank correlation coefficient between the movement quality measured in the SMT and functional limitation measured on the disability rating index (DRI). The internal consistency was Cronbach's α 0.91. Substantial reliability was found for the items: movement (ICC = 0.68), gait (ICC = 0.69), sitting posture (ICC = 0.63), and respiration (ICC = 0.64). Insufficient reliability was found for standing posture (ICC = 0.23). A moderate correlation was found between average test score SMT and the DRI (r = -0.37) and respiration and DRI (r = -0.45). The SMT is a reasonably reliable tool to assess movement, gait, sitting posture, and respiration. None of the items in the domain standing posture has sufficient reliability. A thorough study of this domain should be considered. The results show little evidence for convergent validity. Several items of the SMT correlated moderately with functional limitation with the DRI. These items were global movement, hip flexion, pelvis rotation, and all respiration items.

  13. Standard Review Plan for Environmental Restoration Program Quality Management Plans

    International Nuclear Information System (INIS)

    1993-12-01

    The Department of Energy, Richland Operations Office (RL) Manual Environmental Restoration Program Quality System Requirements (QSR) for the Hanford Site, defines all quality requirements governing Hanford Environmental Restoration (ER) Program activities. The QSR requires that ER Program participants develop Quality Management Plans (QMPs) that describe how the QSR requirements will be implemented for their assigned scopes of work. This standard review plan (SRP) describes the ER program participant responsibilities for submittal of QMPs to the RL Environmental Restoration Division for review and the RL methodology for performing the reviews of participant QMPS. The SRP serves the following functions: acts as a guide in the development or revision of QMPs to assure that the content is complete and adequate; acts as a checklist to be used by the RL staff in their review of participant QMPs; acts as an index or matrix between the requirements of the QSR and implementing methodologies described in the QMPs; decreases the time and subjectivity of document reviews; and provides a formal, documented method for describing exceptions, modifications, or waivers to established ER Program quality requirements

  14. Guide for monitoring effectiveness of utility Reliability Centered Maintenance (RCM) programs

    International Nuclear Information System (INIS)

    Midgett, W.D.; Wilson, J.F.; Krochmal, D.F.; Owsenek, L.W.

    1991-02-01

    Reliability centered maintenance (RCM) programs help utilities optimize preventive maintenance efforts while improving plant safety and economy through increased dependability of plant components. The project team developed this guide and accompanying methodology based on status updates from the Ginna and San Onofre demonstration projects. These updates addressed areas ranging from system selection to the effectiveness of RCM program implementation. In addition, the team incorporated information from a 12-utility survey soliciting opinions on the need for a methodology to monitor RCM cost-effectiveness. An analysis of the 12-utility survey showed that no techniques had been developed to measure RCM program cost-effectiveness. Thus, this guide addresses two key areas: Pros and cons of various monitoring techniques available to assess the overall effectiveness of RCM and a methodology for specifically evaluating the cost-effectiveness of RCM programs. 1 fig

  15. 75 FR 43059 - Mandatory Reliability Standards for the Calculation of Available Transfer Capability, Capacity...

    Science.gov (United States)

    2010-07-23

    ... Standards for Business Practices and Communications Protocols for Public Utilities July 15, 2010. AGENCY... Practices and Communication Protocols for Public Utilities. Order No. 729-B Order on Rehearing and..., Order No. 729-A, 131 FERC ] 61,109 (2010). \\2\\ Standards for Business Practices and Communication...

  16. Is air-displacement plethysmography a reliable method of detecting ongoing changes in percent body fat within obese children involved in a weight management program?

    DEFF Research Database (Denmark)

    Ewane, Cecile; McConkey, Stacy A; Kreiter, Clarence D

    2010-01-01

    (percent body fat) over time. The gold standard method, hydrodensitometry, has severe limitations for the pediatric population. OBJECTIVE: This study examines the reliability of air-displacement plethysmography (ADP) in detecting percent body fat changes within obese children over time. METHODS: Percent...... body fat by ADP, weight, and body mass index (BMI) were measured for eight obese children aged 5-12 years enrolled in a weight management program over a 12-month period. These measurements were taken at initial evaluation, 1.5 months, 3 months, 6 months, and 12 months to monitor the progress...... of the subjects and detect any changes in these measures over time. Statistical analysis was used to determine the reliability of the data collected. RESULTS: The reliability estimate for percent body fat by ADP was 0.78. This was much lower than the reliability of BMI, 0.98, and weight measurements, 0...

  17. Concept of Draft International Standard for a Unified Approach to Space Program Quality Assurance

    Science.gov (United States)

    Stryzhak, Y.; Vasilina, V.; Kurbatov, V.

    2002-01-01

    For want of the unified approach to guaranteed space project and product quality assurance, implementation of many international space programs has become a challenge. Globalization of aerospace industry and participation of various international ventures with diverse quality assurance requirements in big international space programs requires for urgent generation of unified international standards related to this field. To ensure successful fulfillment of space missions, aerospace companies should design and process reliable and safe products with properties complying or bettering User's (or Customer's) requirements. Quality of the products designed or processed by subcontractors (or other suppliers) should also be in compliance with the main user (customer)'s requirements. Implementation of this involved set of unified requirements will be made possible by creating and approving a system (series) of international standards under a generic title Space Product Quality Assurance based on a system consensus principle. Conceptual features of the baseline standard in this system (series) should comprise: - Procedures for ISO 9000, CEN and ECSS requirements adaptation and introduction into space product creation, design, manufacture, testing and operation; - Procedures for quality assurance at initial (design) phases of space programs, with a decision on the end product made based on the principle of independence; - Procedures to arrange incoming inspection of products delivered by subcontractors (including testing, audit of supplier's procedures, review of supplier's documentation), and space product certification; - Procedures to identify materials and primary products applied; - Procedures for quality system audit at the component part, primary product and materials supplier facilities; - Unified procedures to form a list of basic performances to be under configuration management; - Unified procedures to form a list of critical space product components, and unified

  18. Designing time-of-use program based on stochastic security constrained unit commitment considering reliability index

    International Nuclear Information System (INIS)

    Nikzad, Mehdi; Mozafari, Babak; Bashirvand, Mahdi; Solaymani, Soodabeh; Ranjbar, Ali Mohamad

    2012-01-01

    Recently in electricity markets, a massive focus has been made on setting up opportunities for participating demand side. Such opportunities, also known as demand response (DR) options, are triggered by either a grid reliability problem or high electricity prices. Two important challenges that market operators are facing are appropriate designing and reasonable pricing of DR options. In this paper, time-of-use program (TOU) as a prevalent time-varying program is modeled linearly based on own and cross elasticity definition. In order to decide on TOU rates, a stochastic model is proposed in which the optimum TOU rates are determined based on grid reliability index set by the operator. Expected Load Not Supplied (ELNS) is used to evaluate reliability of the power system in each hour. The proposed stochastic model is formulated as a two-stage stochastic mixed-integer linear programming (SMILP) problem and solved using CPLEX solver. The validity of the method is tested over the IEEE 24-bus test system. In this regard, the impact of the proposed pricing method on system load profile; operational costs and required capacity of up- and down-spinning reserve as well as improvement of load factor is demonstrated. Also the sensitivity of the results to elasticity coefficients is investigated. -- Highlights: ► Time-of-use demand response program is linearly modeled. ► A stochastic model is proposed to determine the optimum TOU rates based on ELNS index set by the operator. ► The model is formulated as a short-term two-stage stochastic mixed-integer linear programming problem.

  19. Unified programs nationally? Strengths and weaknesses of the learning standards

    Directory of Open Access Journals (Sweden)

    Ignacio Polo Martínez

    2014-06-01

    Full Text Available The inclusion of measurable learning standards as an element of the curriculum has definitely opened the door to the connection between the curriculum and external assessments. Since its origin, the potential impact of that element in improving our educational system has been defended and criticized. The truth is that in our country, though all regions are based on the same Royal Decree of core curriculum, and therefore the same reference for the evaluation, curriculum that ultimately applies to students ( teaching-learning- assessment from the different regions can have significant differences . This article proposes, from the analysis of various research , training programs, the plan of action for inspection and the author's own experience in processes of curriculum specifications , assess the potential strengths and weaknesses of the learning standards.

  20. Effect of standardized training on the reliability of the Cochrane risk of bias assessment tool: a prospective study.

    Science.gov (United States)

    da Costa, Bruno R; Beckett, Brooke; Diaz, Alison; Resta, Nina M; Johnston, Bradley C; Egger, Matthias; Jüni, Peter; Armijo-Olivo, Susan

    2017-03-03

    The Cochrane risk of bias tool is commonly criticized for having a low reliability. We aimed to investigate whether training of raters, with objective and standardized instructions on how to assess risk of bias, can improve the reliability of the Cochrane risk of bias tool. In this pilot study, four raters inexperienced in risk of bias assessment were randomly allocated to minimal or intensive standardized training for risk of bias assessment of randomized trials of physical therapy treatments for patients with knee osteoarthritis pain. Two raters were experienced risk of bias assessors who served as reference. The primary outcome of our study was between-group reliability, defined as the agreement of the risk of bias assessments of inexperienced raters with the reference assessments of experienced raters. Consensus-based assessments were used for this purpose. The secondary outcome was within-group reliability, defined as the agreement of assessments within pairs of inexperienced raters. We calculated the chance-corrected weighted Kappa to quantify agreement within and between groups of raters for each of the domains of the risk of bias tool. A total of 56 trials were included in our analysis. The Kappa for the agreement of inexperienced raters with reference across items of the risk of bias tool ranged from 0.10 to 0.81 for the minimal training group and from 0.41 to 0.90 for the standardized training group. The Kappa values for the agreement within pairs of inexperienced raters across the items of the risk of bias tool ranged from 0 to 0.38 for the minimal training group and from 0.93 to 1 for the standardized training group. Between-group differences in Kappa for the agreement of inexperienced raters with reference always favored the standardized training group and was most pronounced for incomplete outcome data (difference in Kappa 0.52, p training on risk of bias assessment may significantly improve the reliability of the Cochrane risk of bias tool.

  1. Standard Review Plan Update and Development Program. Implementing Procedures Document

    Energy Technology Data Exchange (ETDEWEB)

    1992-05-01

    This implementing procedures document (IPD) was prepared for use in implementing tasks under the standard review plan update and development program (SRP-UDP). The IPD provides comprehensive guidance and detailed procedures for SRP-UDP tasks. The IPD is mandatory for contractors performing work for the SRP-UDP. It is guidance for the staff. At the completion of the SRP-UDP, the IPD will be revised (to remove the UDP aspects) and will replace NRR Office Letter No. 800 as long-term maintenance procedures.

  2. Composite Reliability and Standard Errors of Measurement for a Seven-Subtest Short Form of the Wechsler Adult Intelligence Scale-Revised.

    Science.gov (United States)

    Schretlen, David; And Others

    1994-01-01

    Composite reliability and standard errors of measurement were computed for prorated Verbal, Performance, and Full-Scale intelligence quotient (IQ) scores from a seven-subtest short form of the Wechsler Adult Intelligence Scale-Revised. Results with 1,880 adults (standardization sample) indicate that this form is as reliable as the complete test.…

  3. A System Approach to Advanced Practice Clinician Standardization and High Reliability.

    Science.gov (United States)

    Okuno-Jones, Susan; Siehoff, Alice; Law, Jennifer; Juarez, Patricia

    Advanced practice clinicians (APCs) are an integral part of the health care team. Opportunities exist within Advocate Health Care to standardize and optimize APC practice across the system. To enhance the role and talents of APCs, an approach to role definition and optimization of practice and a structured approach to orientation and evaluation are shared. Although in the early stages of development, definition and standardization of accountabilities in a framework to support system changes are transforming the practice of APCs.

  4. Data Standards for the Genomes to Life Program

    Energy Technology Data Exchange (ETDEWEB)

    Arkin, Adam; Ambrosiano, John; Babnigg, Gyorgy; Frank, Ed; Geist,Al; Giometti, Carol; Jacobsen, Janet; Samatova, Nagiza; Slater, Nancy; Taylor, Ron

    2004-01-31

    Existing GTL Projects already have produced volumes of dataand, over the course of the next five years, will produce an estimatedhundreds, or possibly thousands, of terabytes of data from hundreds ofexperiments conducted at dozens of laboratories in National Labs anduniversities across the nation. These data will be the basis forpublications by individual researchers, research groups, andmulti-institutional collaborations, and the basis for future DOEdecisions on funding further research in bioremediation. The short-termand long-term value of the data to project participants, to the DOE, andto the nation depends, however, on being able to access the data and onhow, or whether, the data are archived. The ability to access data is thestarting point for data analysis and interpretation, data integration,data mining, and development of data-driven models. Limited orinefficient data access means that less data are analyzed in acost-effective and timely manner. Data production in the GTL Program willlikely outstrip, or may have already outstripped, the ability to analyzethe data. Being able to access data depends on two key factors: datastandards and implementation of the data standards. For the purpose ofthis proposal, a data standard is defined as a standard, documented wayin which data and information about the data are describe. The attributesof the experiment in which the data were collected need to be known andthe measurements corresponding to the data collected need to bedescribed. In general terms, a data standard could be a form (electronicor paper) that is completed by a researcher or a document that prescribeshow a protocol or experiment should be described in writing.Datastandards are critical to data access because they provide a frameworkfor organizing and managing data. Researchers spend significant amountsof time managing data and information about experiments using labnotebooks, computer files, Excel spreadsheets, etc. In addition, dataoutput format

  5. Status of the reliability centered maintenance program at Ontario Hydro's Bruce 'A' Nuclear Division

    International Nuclear Information System (INIS)

    Khan, I.

    1995-01-01

    Bruce A started a preventive maintenance (PM) quality improvement program in August of 1991. This initiative was taken to address the concerns expressed by the AECB and the Peer Audits finding. The concerns were on the quality of the Bruce A PM Program and its execution in the field. Reliability Centered Maintenance (RCM) analysis was selected as the PM program quality improvement and optimization technique. Therefore, RCM became a key component of Bruce A's Integrated PM program and maintenance strategy. As a result of RCM implementation, and improvements in the work planning and scheduling process, Bruce A is seeing downward trends in the corrective maintenance work load, maintenance preventable forced outages, overdue/missed PM tasks and corrective maintenance backlog. Control Room Operators have reported observing an improvement in systems and equipment response to transients. Other benefits include a documented, controlled and traceable PM program. In addition, the team approach required by RCM has started to improve staff confidence in the PM program which, in turn, is improving the compliance with the PM program. (author)

  6. Effect of standardized training on the reliability of the Cochrane risk of bias assessment tool: a study protocol.

    Science.gov (United States)

    da Costa, Bruno R; Resta, Nina M; Beckett, Brooke; Israel-Stahre, Nicholas; Diaz, Alison; Johnston, Bradley C; Egger, Matthias; Jüni, Peter; Armijo-Olivo, Susan

    2014-12-13

    The Cochrane risk of bias (RoB) tool has been widely embraced by the systematic review community, but several studies have reported that its reliability is low. We aim to investigate whether training of raters, including objective and standardized instructions on how to assess risk of bias, can improve the reliability of this tool. We describe the methods that will be used in this investigation and present an intensive standardized training package for risk of bias assessment that could be used by contributors to the Cochrane Collaboration and other reviewers. This is a pilot study. We will first perform a systematic literature review to identify randomized clinical trials (RCTs) that will be used for risk of bias assessment. Using the identified RCTs, we will then do a randomized experiment, where raters will be allocated to two different training schemes: minimal training and intensive standardized training. We will calculate the chance-corrected weighted Kappa with 95% confidence intervals to quantify within- and between-group Kappa agreement for each of the domains of the risk of bias tool. To calculate between-group Kappa agreement, we will use risk of bias assessments from pairs of raters after resolution of disagreements. Between-group Kappa agreement will quantify the agreement between the risk of bias assessment of raters in the training groups and the risk of bias assessment of experienced raters. To compare agreement of raters under different training conditions, we will calculate differences between Kappa values with 95% confidence intervals. This study will investigate whether the reliability of the risk of bias tool can be improved by training raters using standardized instructions for risk of bias assessment. One group of inexperienced raters will receive intensive training on risk of bias assessment and the other will receive minimal training. By including a control group with minimal training, we will attempt to mimic what many review authors

  7. The design of reliability data bases, part I: review of standard design concepts

    International Nuclear Information System (INIS)

    Cooke, Roger M.

    1996-01-01

    Main styles in the design of reliability data banks (RDB's) are reviewed. The conceptual and mathematical tools underlying these designs are summarized. A key point is the method for assessing failure rates for competing failure modes. The theory of independent competing risk and the relation to colored Poisson processes is explained. The notions of observed and naked failure rates are defined, and their equivalence under the assumption of independence is shown. In conclusion, the needs of different users are compared with the information currently offered

  8. Identifying Strategies Programs Adopt to Meet Healthy Eating and Physical Activity Standards in Afterschool Programs.

    Science.gov (United States)

    Weaver, Robert G; Moore, Justin B; Turner-McGrievy, Brie; Saunders, Ruth; Beighle, Aaron; Khan, M Mahmud; Chandler, Jessica; Brazendale, Keith; Randell, Allison; Webster, Collin; Beets, Michael W

    2017-08-01

    The YMCA of USA has adopted Healthy Eating and Physical Activity (HEPA) Standards for its afterschool programs (ASPs). Little is known about strategies YMCA ASPs are implementing to achieve Standards and these strategies' effectiveness. (1) Identify strategies implemented in YMCA ASPs and (2) evaluate the relationship between strategy implementation and meeting Standards. HEPA was measured via accelerometer (moderate-to-vigorous-physical-activity [MVPA]) and direct observation (snacks served) in 20 ASPs. Strategies were identified and mapped onto a capacity building framework ( Strategies To Enhance Practice [STEPs]). Mixed-effects regression estimated increases in HEPA outcomes as implementation increased. Model-implied estimates were calculated for high (i.e., highest implementation score achieved), moderate (median implementation score across programs), and low (lowest implementation score achieved) implementation for both HEPA separately. Programs implemented a variety of strategies identified in STEPs. For every 1-point increase in implementation score 1.45% (95% confidence interval = 0.33% to 2.55%, p ≤ .001) more girls accumulated 30 min/day of MVPA and fruits and/or vegetables were served on 0.11 more days (95% confidence interval = 0.11-0.45, p ≤ .01). Relationships between implementation and other HEPA outcomes did not reach statistical significance. Still regression estimates indicated that desserts are served on 1.94 fewer days (i.e., 0.40 vs. 2.34) in the highest implementing program than the lowest implementing program and water is served 0.73 more days (i.e., 2.37 vs. 1.64). Adopting HEPA Standards at the national level does not lead to changes in routine practice in all programs. Practical strategies that programs could adopt to more fully comply with the HEPA Standards are identified.

  9. Cultural Adaptation and Reliability of the Compliance with Standard Precautions Scale (CSPS) for Nurses in Brazil 1

    Science.gov (United States)

    Pereira, Fernanda Maria Vieira; Lam, Simon Ching; Gir, Elucir

    2017-01-01

    ABSTRACT Objective: this study aimed to carry of the cultural adaptation and to evaluate the reliability of the Compliance with Standard Precautions Scale (CSPS) for nurses in Brazil. Method: the adaptation process entailed translation, consensus among judges, back-translation, semantic validation and pretest. The reliability was evaluated by internal consistency (Cronbach alpha) and stability (test-retest). The instrument was administered to a sample group of 300 nurses who worked in a large hospital located in the city of São Paulo/SP, Brazil. Results: through the semantic validation, the items from the scale were considered understandable and deemed important for the nurse´s clinical practice. The CSPS Brazilian Portuguese version (CSPS-PB) revealed excellent interpretability. The Cronbach`s alpha was 0.61 and the intraclass correlation coefficient was 0.85. Conclusion: the initial study showed that CSPS-PB is appropriate to assess compliance with standard precautions among nurses in Brazil. The reliability was considered acceptable. Furhter study is necessary to evaluate its comprehensive psychometric properties. PMID:28301030

  10. [Reliability and validity of the standardized Mini Mental State Examination in the diagnosis of mild dementia in Turkish population].

    Science.gov (United States)

    Güngen, Can; Ertan, Turan; Eker, Engin; Yaşar, Resmiye; Engin, Funda

    2002-01-01

    Reliability and validity of the Mini Mental State Examination in differentiating mild dementia from normal controls in Turkish population. The Standardized Mini Mental State Examination (SMMSE) and its instruction were translated into Turkish. A total of 212 subjects with mean age of 77 +/- 6, were recruited for the study. 71 were diagnosed to be demented and 141 were evaluated as normal controls. The scale total score was analysed for discriminant validity using Student's t-test. Sensitivity, specificity, positive and negative predictive values and kappa score were calculated for all of the scores between 18 and 29. Kappa value was calculated for the comparison of the dementia diagnosis between the two investigators using the best cut off score obtained in the analysis above. Statistical analysis revealed that the Turkish version of the SMMSE has high discriminant validity and interrater reliability in the diagnosis of mild dementia. The cut off score 23/24 was found to have the highest sensitivity (0.91), specificity (0.95), positive and negative predictive values (0.90 and 0.95) and kappa score (0.86). Interrater reliability analysis showed high correlation (r:0.99) and kappa value (0.92). The results of this study showed that the Turkish version of the SMMSE has high reliability and validity for the diagnosis of mild dementia in Turkish population.

  11. Empiric reliability of diagnostic and prognostic estimations of physical standards of children, going in for sports.

    Directory of Open Access Journals (Sweden)

    Zaporozhanov V.A.

    2012-12-01

    Full Text Available In the conditions of sporting-pedagogical practices objective estimation of potential possibilities gettings busy already on the initial stages of long-term preparation examined as one of issues of the day. The proper quantitative information allows to individualize preparation of gettings in obedience to requirements to the guided processes busy. Research purpose - logically and metrical to rotin expedience of metrical method of calculations of reliability of results of the control measurings, in-use for diagnostics of psychophysical fitness and prognosis of growth of trade gettings busy in the select type of sport. Material and methods. Analysed the results of the control measurings on four indexes of psychophysical preparedness and estimation of experts of fitness 24th gettings busy composition of children of gymnastic school. The results of initial and final inspection of gymnasts on the same control tests processed the method of mathematical statistics. Expected the metrical estimations of reliability of measurings is stability, co-ordination and informing of control information for current diagnostics and prognosis of sporting possibilities inspected. Results. Expedience of the use in these aims of metrical operations of calculation of complex estimation of the psychophysical state of gettings busy is metrology grounded. Conclusions. Research results confirm expedience of calculation of complex estimation of psychophysical features gettings busy for diagnostics of fitness in the select type of sport and trade prognosis on the subsequent stages of preparation.

  12. 78 FR 18817 - Revisions to Reliability Standard for Transmission Vegetation Management

    Science.gov (United States)

    2013-03-28

    ... used in the technical reference paper [Exh. A of NERC's petition].'' \\25\\ \\24\\ NERC Petition, Ex. I... set by Institute of Electric and Electronics Engineers (IEEE) Standard 516 that, as indicated in Order... Power Research Institute (EPRI) is planning to undertake field tests of energized high voltage conductor...

  13. 75 FR 39244 - Reliability Standards Development and NERC and Regional Entity Enforcement; Further Notice...

    Science.gov (United States)

    2010-07-08

    ... Standards Development and NERC and Regional Entity Enforcement; Further Notice Concerning Technical... convene a Commissioner-led technical conference regarding issues pertaining to the development of... Corporation and the Regional Entities as previously announced.\\1\\ \\1\\ Notice of Technical Conference, 75 FR 35...

  14. Reliability Analysis of RSG-GAS Primary Cooling System to Support Aging Management Program

    Science.gov (United States)

    Deswandri; Subekti, M.; Sunaryo, Geni Rina

    2018-02-01

    Multipurpose Research Reactor G.A. Siwabessy (RSG-GAS) which has been operating since 1987 is one of the main facilities on supporting research, development and application of nuclear energy programs in BATAN. Until now, the RSG-GAS research reactor has been successfully operated safely and securely. However, because it has been operating for nearly 30 years, the structures, systems and components (SSCs) from the reactor would have started experiencing an aging phase. The process of aging certainly causes a decrease in reliability and safe performances of the reactor, therefore the aging management program is needed to resolve the issues. One of the programs in the aging management is to evaluate the safety and reliability of the system and also screening the critical components to be managed.One method that can be used for such purposes is the Fault Tree Analysis (FTA). In this papers FTA method is used to screening the critical components in the RSG-GAS Primary Cooling System. The evaluation results showed that the primary isolation valves are the basic events which are dominant against the system failure.

  15. Reliable LC-MS quantitative glycomics using iGlycoMab stable isotope labeled glycans as internal standards.

    Science.gov (United States)

    Zhou, Shiyue; Tello, Nadia; Harvey, Alex; Boyes, Barry; Orlando, Ron; Mechref, Yehia

    2016-06-01

    Glycans have numerous functions in various biological processes and participate in the progress of diseases. Reliable quantitative glycomic profiling techniques could contribute to the understanding of the biological functions of glycans, and lead to the discovery of potential glycan biomarkers for diseases. Although LC-MS is a powerful analytical tool for quantitative glycomics, the variation of ionization efficiency and MS intensity bias are influencing quantitation reliability. Internal standards can be utilized for glycomic quantitation by MS-based methods to reduce variability. In this study, we used stable isotope labeled IgG2b monoclonal antibody, iGlycoMab, as an internal standard to reduce potential for errors and to reduce variabililty due to sample digestion, derivatization, and fluctuation of nanoESI efficiency in the LC-MS analysis of permethylated N-glycans released from model glycoproteins, human blood serum, and breast cancer cell line. We observed an unanticipated degradation of isotope labeled glycans, tracked a source of such degradation, and optimized a sample preparation protocol to minimize degradation of the internal standard glycans. All results indicated the effectiveness of using iGlycoMab to minimize errors originating from sample handling and instruments. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Reliable change indices and standardized regression-based change score norms for evaluating neuropsychological change in children with epilepsy.

    Science.gov (United States)

    Busch, Robyn M; Lineweaver, Tara T; Ferguson, Lisa; Haut, Jennifer S

    2015-06-01

    Reliable change indices (RCIs) and standardized regression-based (SRB) change score norms permit evaluation of meaningful changes in test scores following treatment interventions, like epilepsy surgery, while accounting for test-retest reliability, practice effects, score fluctuations due to error, and relevant clinical and demographic factors. Although these methods are frequently used to assess cognitive change after epilepsy surgery in adults, they have not been widely applied to examine cognitive change in children with epilepsy. The goal of the current study was to develop RCIs and SRB change score norms for use in children with epilepsy. Sixty-three children with epilepsy (age range: 6-16; M=10.19, SD=2.58) underwent comprehensive neuropsychological evaluations at two time points an average of 12 months apart. Practice effect-adjusted RCIs and SRB change score norms were calculated for all cognitive measures in the battery. Practice effects were quite variable across the neuropsychological measures, with the greatest differences observed among older children, particularly on the Children's Memory Scale and Wisconsin Card Sorting Test. There was also notable variability in test-retest reliabilities across measures in the battery, with coefficients ranging from 0.14 to 0.92. Reliable change indices and SRB change score norms for use in assessing meaningful cognitive change in children following epilepsy surgery are provided for measures with reliability coefficients above 0.50. This is the first study to provide RCIs and SRB change score norms for a comprehensive neuropsychological battery based on a large sample of children with epilepsy. Tables to aid in evaluating cognitive changes in children who have undergone epilepsy surgery are provided for clinical use. An Excel sheet to perform all relevant calculations is also available to interested clinicians or researchers. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. A reliable parameter to standardize the scoring of stem cell spheres.

    Directory of Open Access Journals (Sweden)

    Xiaochen Zhou

    Full Text Available Sphere formation assay is widely used in selection and enrichment of normal stem cells or cancer stem cells (CSCs, also known as tumor initiating cells (TICs, based on their ability to grow in serum-free suspension culture for clonal proliferation. However, there is no standardized parameter to accurately score the spheres, which should be reflected by both the number and size of the spheres. Here we define a novel parameter, designated as Standardized Sphere Score (SSS, which is expressed by the total volume of selected spheres divided by the number of cells initially plated. SSS was validated in quantification of both tumor spheres from cancer cell lines and embryonic bodies (EB from mouse embryonic stem cells with high sensitivity and reproducibility.

  18. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Quality Assurance Manual

    Energy Technology Data Exchange (ETDEWEB)

    C. L. Smith; R. Nims; K. J. Kvarfordt; C. Wharton

    2008-08-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment using a personal computer running the Microsoft Windows operating system. SAPHIRE is primarily funded by the U.S. Nuclear Regulatory Commission (NRC). The role of the INL in this project is that of software developer and tester. This development takes place using formal software development procedures and is subject to quality assurance (QA) processes. The purpose of this document is to describe how the SAPHIRE software QA is performed for Version 6 and 7, what constitutes its parts, and limitations of those processes.

  19. Designing and Assessing the Validity and Reliability of the Hospital Readiness Assessment Tools to Conducting Quality Improvement Program

    Directory of Open Access Journals (Sweden)

    Kamal Gholipoor

    2016-09-01

    Full Text Available Background and objectives : Identifying the readiness of hospital and its strengths and weaknesses can be useful in developing appropriate planning and situation analyses and management to getting effective in clinical audit programs. The aim of this study was to design and assess the validity of the Hospital Readiness Assessment Tools to conduct quality improvement and clinical audit programs. Material and Methods: In this study, based on the results of a systematic review of literature, an initial questionnaire with 77 items was designed. Questionnaire content validity was reviewed by experts in the field of hospital management and quality improvement in Tabriz University of Medical Sciences. For this purpose, 20 questionnaires were sent to experts. Finally, 15 participants returned completed questionnaire. Questionnaire validity was reviewed and confirmed based on Content Validity Index and Content Validity Ratio. Questionnaire reliability was confirmed based on Cronbach's alpha index (α = 0.96 in a pilot study by participation of 30 hospital managers. Results: The results showed that the final questionnaire contains 54 questions as nine category as: data and information (9 items, teamwork (12 questions, resources (5 questions, patient and education (5, intervention design and implementation (5 questions, clinical audit management (4 questions, human resources (6 questions, evidence and standard (4 items and evaluation and feedback (4 items. The final questionnaire content validity index was 0.91 and final questionnaire Cronbach's alpha coefficient was 0.96. Conclusion: Considering the relative good validity and reliability of the designed tool in this study, it appears that the questionnaire can be used to identify and assess the readiness of hospitals for quality improvement and clinical audit program implementation

  20. 75 FR 18850 - National Protection and Programs Directorate; Chemical Facility Anti-Terrorism Standards...

    Science.gov (United States)

    2010-04-13

    ... Directorate; Chemical Facility Anti-Terrorism Standards Personnel Surety Program AGENCY: National Protection...-terrorism Vulnerability Information (CVI), Sensitive Security Information (SSI), or Protected Critical... . SUPPLEMENTARY INFORMATION: Program Description The Chemical Facility Anti-Terrorism Standards (CFATS), 6 CFR...

  1. The Reliability of Multisource Feedback in Competency-Based Assessment Programs: The Effects of Multiple Occasions and Assessor Groups

    NARCIS (Netherlands)

    Moonen-van Loon, J.M.; Overeem, K.; Govaerts, M.J.; Verhoeven, B.H.; Vleuten, C.P.M. van der; Driessen, E.W.

    2015-01-01

    PURPOSE: Residency programs around the world use multisource feedback (MSF) to evaluate learners' performance. Studies of the reliability of MSF show mixed results. This study aimed to identify the reliability of MSF as practiced across occasions with varying numbers of assessors from different

  2. International Review of Standards and Labeling Programs for Distribution Transformers

    Energy Technology Data Exchange (ETDEWEB)

    Letschert, Virginie [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Scholand, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Carreño, Ana María [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hernandez, Carolina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-06-20

    Transmission and distribution (T&D) losses in electricity networks represent 8.5% of final energy consumption in the world. In Latin America, T&D losses range between 6% and 20% of final energy consumption, and represent 7% in Chile. Because approximately one-third of T&D losses take place in distribution transformers alone, there is significant potential to save energy and reduce costs and carbon emissions through policy intervention to increase distribution transformer efficiency. A large number of economies around the world have recognized the significant impact of addressing distribution losses and have implemented policies to support market transformation towards more efficient distribution transformers. As a result, there is considerable international experience to be shared and leveraged to inform countries interested in reducing distribution losses through policy intervention. The report builds upon past international studies of standards and labeling (S&L) programs for distribution transformers to present the current energy efficiency programs for distribution transformers around the world.

  3. A Method for Developing Standard Patient Education Program.

    Science.gov (United States)

    Lura, Carolina Bryne; Hauch, Sophie Misser Pallesgaard; Gøeg, Kirstine Rosenbeck; Pape-Haugaard, Louise

    2018-01-01

    In Denmark, patients being treated on Haematology Outpatients Departments get instructed to self-manage their blood sample collection from Central Venous Catheter (CVC). However, this is a complex and risky procedure, which can jeopardize patient safety. The aim of the study was to suggest a method for developing standard digital patient education programs for patients in self-administration of blood samples drawn from CVC. The Design Science Research Paradigm was used to develop a digital patient education program, called PAVIOSY, to increase patient safety during execution of the blood sample collection procedure by using videos for teaching as well as procedural support. A step-by-step guide was developed and used as basis for making the videos. Quality assurance through evaluation with a nurse was conducted on both the step-by-step guide and the videos. The quality assurance evaluation of the videos showed; 1) Errors due to the order of the procedure can be determined by reviewing the videos despite that the guide was followed. 2) Videos can be used to identify errors - important for patient safety - in the procedure, which are not identifiable in a written script. To ensure correct clinical content of the educational patient system, health professionals must be engaged early in the development of content and design phase.

  4. Use of standard reliability levels in design and safety assessment of in-pile loops

    International Nuclear Information System (INIS)

    Bogani, G.; Verre, A.; Balestreri, S.; Colombo, A.G.; Luisi, T.

    1975-01-01

    This paper describes a logic-probabilistic analysis technique for a critical design review and safety assessment of in-pile loops. The examples in this paper refer to the analysis performed for the experimental loops already constructed or under construction in the ESSOR reactor of the Joint Research Centre of Ispra, as irradiation facilities for fuel element research and development tests. The proposed technique is based on the classification into categories of components and protective device malfunctions. Such subdivision into categories was agreed upon by the Italian Safety Authority and Euratom JRC, and adopted for the safety assessment of the ESSOR reactor in-pile loops. For each category, the method makes a link with a corresponding malfunction probability range (probability level). This probability level is defined taking into account design, construction, inspection and maintenance criteria as well as periodic controls; therefore the quality level and consequently the reliability level are thus also defined. The analysis is developed in the following stages: (1) definition of the analysis object (top event) and drawing of the relative fault-tree; (2) loop design analysis and preliminary optimization based on logic criteria; (3) classification into categories of the fault-tree primary events; (4) final loop design analysis and optimization based on defined component quality requirements. Stages 2 and 4 are quite different since stage 2 mainly consists of a redundance optimization, while stage 4 acts on the component quality level in such a way that each minimum cut-set leading to the top has an acceptable probability level. During analysis development, use is made of computer codes which, among other things enable the verification of fault-tree logic makeup, the listing of the minimum cut-sets with and without event categorization, and the evaluation of each cut-set order. (author)

  5. 41 CFR 102-194.5 - What is the Standard and Optional Forms Management Program?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What is the Standard and Optional Forms Management Program? 102-194.5 Section 102-194.5 Public Contracts and Property Management... PROGRAMS 194-STANDARD AND OPTIONAL FORMS MANAGEMENT PROGRAM § 102-194.5 What is the Standard and Optional...

  6. 40 CFR 131.8 - Requirements for Indian Tribes to administer a water quality standards program.

    Science.gov (United States)

    2010-07-01

    ... administer a water quality standards program. 131.8 Section 131.8 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS WATER QUALITY STANDARDS General Provisions § 131.8 Requirements for Indian Tribes to administer a water quality standards program. (a) The Regional Administrator, as...

  7. 75 FR 37733 - Regulation of Fuels and Fuel Additives: Modifications to Renewable Fuel Standard Program

    Science.gov (United States)

    2010-06-30

    ... Regulation of Fuels and Fuel Additives: Modifications to Renewable Fuel Standard Program AGENCY... direct final rule to amend the Renewable Fuel Standard program requirements on May 10, 2010. Because EPA... Fuel Standard program requirements, published on May 10, 2010. We stated in that direct final rule that...

  8. Review of predialysis education programs: a need for standardization

    Directory of Open Access Journals (Sweden)

    Van den Bosch J

    2015-09-01

    Full Text Available Judith Van den Bosch,1 D Simone Warren,1 Peter A Rutherford21Pallas Health Research and Consultancy BV, Rotterdam, the Netherlands; 2Baxter Healthcare SA, Zürich, SwitzerlandAbstract: To make an informed decision on renal replacement therapy, patients should receive education about dialysis options in a structured program covering all modalities. Many patients do not receive such education, and there is disparity in the information they receive. This review aims to compile evidence on effective components of predialysis education programs as related to modality choice and outcomes. PubMed MEDLINE, Cochrane Library, and Ovid searches (from January 1, 1995 to December 31, 2013 with the main search terms of “predialysis”, “peritoneal dialysis”, “home dialysis”, “education”, “information”, and “decision” were performed. Of the 1,005 articles returned from the initial search, 110 were given full text reviews as they potentially met inclusion criteria (for example, they included adults or predialysis patients, or the details of an education program were reported. Only 29 out of the 110 studies met inclusion criteria. Ten out of 13 studies using a comparative design, showed an increase in home dialysis choice after predialysis education. Descriptions of the educational process varied and included individual and group education, multidisciplinary intervention, and varying duration and frequency of sessions. Problem-solving group sessions seem to be an effective component for enhancing the proportion of home dialysis choice. Evidence is lacking for many components, such as timing and staff competencies. There is a need for a standardized approach to evaluate the effect of predialysis educational interventions.Keywords: dialysis, end-stage renal disease, informed decision, modality choice

  9. Reliability and agreement between 2 strength devices used in the newly modified and standardized Constant score

    DEFF Research Database (Denmark)

    Kristensen, Morten Tange; Aagesen, Maria; Hjerrild, Signe

    2014-01-01

    HYPOTHESIS: The new and standardized test protocol for the Constant score (CS) provides new methodology, but different devices are still used for shoulder strength testing. It was hypothesized that strength measurements using the IsoForceControl (IFC) dynamometer (MDS Medical Device Solutions......, Oberburg, Switzerland) would provide results comparable with the IDO isometer (Innovative Design Orthopaedics, Redditch, UK). MATERIALS AND METHODS: Sixty healthy subjects, aged 19 to 83 years, were studied, with 5 men and 5 women in each of 6 ten-year age groups. The IFC and IDO were used in randomized...... order with an 8-minute interval between testing. Subjects performed 3 successive trials with strong verbal encouragement, with 1 minute between trials. The best strength performance was used in the analysis. The rater and subjects were blinded to all results. RESULTS: The IFC produced 0.28-kg (0.62-lb...

  10. Reliable Change Indices and Standardized Regression-Based Change Score Norms for Evaluating Neuropsychological Change in Children with Epilepsy

    Science.gov (United States)

    Busch, Robyn M.; Lineweaver, Tara T.; Ferguson, Lisa; Haut, Jennifer S.

    2015-01-01

    Reliable change index scores (RCIs) and standardized regression-based change score norms (SRBs) permit evaluation of meaningful changes in test scores following treatment interventions, like epilepsy surgery, while accounting for test-retest reliability, practice effects, score fluctuations due to error, and relevant clinical and demographic factors. Although these methods are frequently used to assess cognitive change after epilepsy surgery in adults, they have not been widely applied to examine cognitive change in children with epilepsy. The goal of the current study was to develop RCIs and SRBs for use in children with epilepsy. Sixty-three children with epilepsy (age range 6–16; M=10.19, SD=2.58) underwent comprehensive neuropsychological evaluations at two time points an average of 12 months apart. Practice adjusted RCIs and SRBs were calculated for all cognitive measures in the battery. Practice effects were quite variable across the neuropsychological measures, with the greatest differences observed among older children, particularly on the Children’s Memory Scale and Wisconsin Card Sorting Test. There was also notable variability in test-retest reliabilities across measures in the battery, with coefficients ranging from 0.14 to 0.92. RCIs and SRBs for use in assessing meaningful cognitive change in children following epilepsy surgery are provided for measures with reliability coefficients above 0.50. This is the first study to provide RCIs and SRBs for a comprehensive neuropsychological battery based on a large sample of children with epilepsy. Tables to aid in evaluating cognitive changes in children who have undergone epilepsy surgery are provided for clinical use. An excel sheet to perform all relevant calculations is also available to interested clinicians or researchers. PMID:26043163

  11. Systems analysis programs for hands-on integrated reliability evaluations (SAPHIRE), Version 5.0

    International Nuclear Information System (INIS)

    Russell, K.D.; Kvarfordt, K.J.; Hoffman, C.L.

    1995-10-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. The Graphical Evaluation Module (GEM) is a special application tool designed for evaluation of operational occurrences using the Accident Sequence Precursor (ASP) program methods. GEM provides the capability for an analyst to quickly and easily perform conditional core damage probability (CCDP) calculations. The analyst can then use the CCDP calculations to determine if the occurrence of an initiating event or a condition adversely impacts safety. It uses models and data developed in the SAPHIRE specially for the ASP program. GEM requires more data than that normally provided in SAPHIRE and will not perform properly with other models or data bases. This is the first release of GEM and the developers of GEM welcome user comments and feedback that will generate ideas for improvements to future versions. GEM is designated as version 5.0 to track GEM codes along with the other SAPHIRE codes as the GEM relies on the same, shared database structure

  12. A study of adopting maintenance rule under the periodic safety review and reliability centered maintenance program

    International Nuclear Information System (INIS)

    Kilyoo, Kim

    2001-01-01

    U.S Maintenance Rule (MR) has three main functions. One is to monitor the performance changes of SSCs (Structure, System, and Component) caused by risk informed applications. Periodic Safety Review (PSR) program is widely adopted in Europe while it is not adopted in U. S. A where MR and new oversight program are instead used. Recently, in Korea, it was determined to adopt PSR, and the first PSR program has started this year for Kori unit 1 as a pilot plant. Also, a traditional Reliability Centered Maintenance (RCM) has been performed for 4 systems of YGN unit 1 and 2 and it will be applied to the other nuclear power plants in Korea. However, since MR is adopting many useful concept of RCM, traditional RCM could not be further performed without being associated with MR. Thus, MR, RCM and PSR have recently become hot issue policies which should be well associated each other in Korea, and this paper suggests a desirable new maintenance process which would embrace the concepts of the three policies, and also discusses whether U.S. MR is necessary even though a PSR program is already adopted, and if necessary, then how cost-effectively it can be introduced to. (author)

  13. The rating reliability calculator

    Directory of Open Access Journals (Sweden)

    Solomon David J

    2004-04-01

    Full Text Available Abstract Background Rating scales form an important means of gathering evaluation data. Since important decisions are often based on these evaluations, determining the reliability of rating data can be critical. Most commonly used methods of estimating reliability require a complete set of ratings i.e. every subject being rated must be rated by each judge. Over fifty years ago Ebel described an algorithm for estimating the reliability of ratings based on incomplete data. While his article has been widely cited over the years, software based on the algorithm is not readily available. This paper describes an easy-to-use Web-based utility for estimating the reliability of ratings based on incomplete data using Ebel's algorithm. Methods The program is available public use on our server and the source code is freely available under GNU General Public License. The utility is written in PHP, a common open source imbedded scripting language. The rating data can be entered in a convenient format on the user's personal computer that the program will upload to the server for calculating the reliability and other statistics describing the ratings. Results When the program is run it displays the reliability, number of subject rated, harmonic mean number of judges rating each subject, the mean and standard deviation of the averaged ratings per subject. The program also displays the mean, standard deviation and number of ratings for each subject rated. Additionally the program will estimate the reliability of an average of a number of ratings for each subject via the Spearman-Brown prophecy formula. Conclusion This simple web-based program provides a convenient means of estimating the reliability of rating data without the need to conduct special studies in order to provide complete rating data. I would welcome other researchers revising and enhancing the program.

  14. DOE [Department of Energy]-Nuclear Energy Standards Program annual assessment, FY 1990

    International Nuclear Information System (INIS)

    Williams, D.L. Jr.

    1990-11-01

    To meet the objectives of the programs funded by the Department of Energy (DOE)-Nuclear Energy (NE) Technology Support Programs, the Performance Assurance Project Office (PAPO) administers a nuclear standards program and related activities and fosters the development and application of standards. This standards program is carried out in accordance with the principles in DOE Order 1300.2, Department of Energy Standards Program, December 18, 1980. The purposes of this effort, as set forth in three subtasks, are to (1) manage the NE Standards Program, (2) manage the development and maintenance of NE standards, and (3) operate an NE Standards Information Program. This report assesses the Performance Assurance Project Office (PAPO) activities in terms of the objectives of the Department of Energy-Nuclear Energy (DOE-NE) funded programs. To meet these objectives, PAPO administers a nuclear standards program and related activities and fosters the development and application of standards. This task is carried out in accordance with the principles set forth in DOE Order 1300.2, Department of Energy Standards Program, December 18, 1980, and DOE memorandum, Implementation of DOE Orders on Quality Assurance, Standards, and Unusual Occurrence Reporting for Nuclear Energy Programs, March 3, 1982, and with guidance from the DOE-NE Technology Support Programs. 1 tab. (JF)

  15. Development and inter-rater reliability of a standardized verbal instruction manual for the Chinese Geriatric Depression Scale-short form.

    Science.gov (United States)

    Wong, M T P; Ho, T P; Ho, M Y; Yu, C S; Wong, Y H; Lee, S Y

    2002-05-01

    The Geriatric Depression Scale (GDS) is a common screening tool for elderly depression in Hong Kong. This study aimed at (1) developing a standardized manual for the verbal administration and scoring of the GDS-SF, and (2) comparing the inter-rater reliability between the standardized and non-standardized verbal administration of GDS-SF. Two studies were reported. In Study 1, the process of developing the manual was described. In Study 2, we compared the inter-rater reliabilities of GDS-SF scores using the standardized verbal instructions and the traditional non-standardized administration. Results of Study 2 indicated that the standardized procedure in verbal administration and scoring improved the inter-rater reliabilities of GDS-SF. Copyright 2002 John Wiley & Sons, Ltd.

  16. After reliability centred maintenance. Preventive maintenance living program implementation at Bruce Power

    International Nuclear Information System (INIS)

    Harazim, Michael L.; Ferguson, Brian J.

    2003-01-01

    Industrial preventive maintenance (PM) programs represent a large part of plant O and M costs. PM Optimization (PMO) projects represent an effective mechanism for identifying unnecessary PM, extending PM intervals and infusing predictive maintenance (PdM) methods. However, once optimized, what process prevents the PM program from returning to a state of disarray? This is the function of a PM living program (PMLP). In 1997, an independent performance assessment identified concerns with the applicability and effectiveness of all Ontario Power Generation, Inc. (OPGI) PM programs. In response, OPGI instituted an Integrated Maintenance Program (IMP) including Reliability Centred Maintenance (RCM) and a PMLP. It should be noted that the PMLP was developed for the 3 OPGI nuclear Sites (i.e. Bruce, Pickering, and Darlington). Effective 1 May 2001, the Bruce Site has been leased to a group of investors lead by British Energy. This paper is written in historical context and therefore refers to the Bruce Site as part of OPGI. The PMLP is made up of five elements: 1) process control, 2) change control, 3) worker feedback, 4) program performance metrics, and 5) deferral module. A PMLP software tool, originally applied to Duke Energy nuclear plants, was enhanced and customized specifically for the OPGI PMLP, and then implemented at all three of OPGI's nuclear sites. The objective of the OPGI PMLP was to: Provide processes/procedures for continual optimization of all site PM tasks, Ensure effective and timely revision of PM tasks in the work management system, Ensure PM tasks remain applicable/effective at all times, Maintain and enhance PM consistency on a component, system and Site basis, Ensure that new predictive maintenance techniques are applied and integrated with the PM program, Ensure that mandated PM tasks are identified and executed, Provide a mechanism for craft feedback, Meet regulatory requirements for PM program effectiveness, and Provide PM task deferral

  17. Test-Retest Reliability of Standard and Emotional Stroop Tasks: An Investigation of Color-Word and Picture-Word Versions

    Science.gov (United States)

    Strauss, Gregory P.; Allen, Daniel N.; Jorgensen, Melinda L.; Cramer, Stacey L.

    2005-01-01

    Previous studies have examined the reliability of scores derived from various Stroop tasks. However, few studies have compared reliability of more recently developed Stroop variants such as emotional Stroop tasks to standard versions of the Stroop. The current study developed four different single-stimulus Stroop tasks and compared test-retest…

  18. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE), Version 5.0: Integrated Reliability and Risk Analysis System (IRRAS) reference manual. Volume 2

    International Nuclear Information System (INIS)

    Russell, K.D.; Kvarfordt, K.J.; Skinner, N.L.; Wood, S.T.; Rasmuson, D.M.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. The Integrated Reliability and Risk Analysis System (IRRAS) is a state-of-the-art, microcomputer-based probabilistic risk assessment (PRA) model development and analysis tool to address key nuclear plant safety issues. IRRAS is an integrated software tool that gives the use the ability to create and analyze fault trees and accident sequences using a microcomputer. This program provides functions that range from graphical fault tree construction to cut set generation and quantification to report generation. Version 1.0 of the IRRAS program was released in February of 1987. Since then, many user comments and enhancements have been incorporated into the program providing a much more powerful and user-friendly system. This version has been designated IRRAS 5.0 and is the subject of this Reference Manual. Version 5.0 of IRRAS provides the same capabilities as earlier versions and ads the ability to perform location transformations, seismic analysis, and provides enhancements to the user interface as well as improved algorithm performance. Additionally, version 5.0 contains new alphanumeric fault tree and event used for event tree rules, recovery rules, and end state partitioning

  19. Biocoder: A programming language for standardizing and automating biology protocols.

    Science.gov (United States)

    Ananthanarayanan, Vaishnavi; Thies, William

    2010-11-08

    Published descriptions of biology protocols are often ambiguous and incomplete, making them difficult to replicate in other laboratories. However, there is increasing benefit to formalizing the descriptions of protocols, as laboratory automation systems (such as microfluidic chips) are becoming increasingly capable of executing them. Our goal in this paper is to improve both the reproducibility and automation of biology experiments by using a programming language to express the precise series of steps taken. We have developed BioCoder, a C++ library that enables biologists to express the exact steps needed to execute a protocol. In addition to being suitable for automation, BioCoder converts the code into a readable, English-language description for use by biologists. We have implemented over 65 protocols in BioCoder; the most complex of these was successfully executed by a biologist in the laboratory using BioCoder as the only reference. We argue that BioCoder exposes and resolves ambiguities in existing protocols, and could provide the software foundations for future automation platforms. BioCoder is freely available for download at http://research.microsoft.com/en-us/um/india/projects/biocoder/. BioCoder represents the first practical programming system for standardizing and automating biology protocols. Our vision is to change the way that experimental methods are communicated: rather than publishing a written account of the protocols used, researchers will simply publish the code. Our experience suggests that this practice is tractable and offers many benefits. We invite other researchers to leverage BioCoder to improve the precision and completeness of their protocols, and also to adapt and extend BioCoder to new domains.

  20. Reliability and availability of redundant systems: Computational program and the use of nomograms

    International Nuclear Information System (INIS)

    Signoret, J.P.

    1975-01-01

    A rigorous mathematical approach to determining the reliability and availability of repairable actively redundant systems - (r/m) systems - is considered for the case where the m units comprising the system are identical and the failure and repair rates, lambda and μ respectively, are constant. The method used involves the Markov processes, operator calculus and matrix calculus. All the results of the study are handled by the FIDIAS program, which is a practical tool for calculating with a high degree of precision the reliability or availability of such (r/m) systems whatever the values of m and r. In the FIDIAS-TC version of FIDIAS it is possible to plot curves with a Benson plotter, so that nomograms are produced for rapid and simple determination of the probabilities of failure or non-availability of the (r/m) systems considered. The practical application of nomograms is of interest because (2/3) and (2/4) actively redundant systems are very often used in the control circuits of power reactors. It is shown how easily one can compare these two systems using nomograms and how one can determine lambda or μ as a function of the anticipated result

  1. Improving reliability of state estimation programming and computing suite based on analyzing a fault tree

    Directory of Open Access Journals (Sweden)

    Kolosok Irina

    2017-01-01

    Full Text Available Reliable information on the current state parameters obtained as a result of processing the measurements from systems of the SCADA and WAMS data acquisition and processing through methods of state estimation (SE is a condition that enables to successfully manage an energy power system (EPS. SCADA and WAMS systems themselves, as any technical systems, are subject to failures and faults that lead to distortion and loss of information. The SE procedure enables to find erroneous measurements, therefore, it is a barrier for the distorted information to penetrate into control problems. At the same time, the programming and computing suite (PCS implementing the SE functions may itself provide a wrong decision due to imperfection of the software algorithms and errors. In this study, we propose to use a fault tree to analyze consequences of failures and faults in SCADA and WAMS and in the very SE procedure. Based on the analysis of the obtained measurement information and on the SE results, we determine the state estimation PCS fault tolerance level featuring its reliability.

  2. Interim reliability evaluation program: analysis of the Arkansas Nuclear One. Unit 1 Nuclear Power Plant

    International Nuclear Information System (INIS)

    Kolb, G.J.; Kunsman, D.M.; Bell, B.J.

    1982-06-01

    This report represents the results of the analysis of Arkansas Nuclear One (ANO) Unit 1 nuclear power plant which was performed as part of the Interim Reliability Evaluation Program (IREP). The IREP has several objectives, two of which are achieved by the analysis presented in this report. These objectives are: (1) the identification, in a preliminary way, of those accident sequences which are expected to dominate the public health and safety risks; and (2) the development of state-of-the-art plant system models which can be used as a foundation for subsequent, more intensive applications of probabilistic risk assessment. The primary methodological tools used in the analysis were event trees and fault trees. These tools were used to study core melt accidents initiated by loss of coolant accidents (LOCAs) of six different break size ranges and eight different types of transients

  3. Improving human reliability through better nuclear power plant system design: Program for advanced nuclear power studies

    International Nuclear Information System (INIS)

    Golay, M.W.

    1993-01-01

    The project on ''Development of a Theory of the Dependence of Human Reliability upon System Designs as a Means of Improving Nuclear Power Plant Performance'' was been undertaken in order to address the problem of human error in advanced nuclear power plant designs. Lack of a mature theory has retarded progress in reducing likely frequencies of human errors. Work being pursued in this project is to perform a set of experiments involving human subjects who are required to operate, diagnose and respond to changes in computer-simulated systems, relevant to those encountered in nuclear power plants, which are made to differ in complexity in a systematic manner. The computer program used to present the problems to be solved also records the response of the operator as it unfolds

  4. A dynamic programming algorithm for the buffer allocation problem in homogeneous asymptotically reliable serial production lines

    Directory of Open Access Journals (Sweden)

    Diamantidis A. C.

    2004-01-01

    Full Text Available In this study, the buffer allocation problem (BAP in homogeneous, asymptotically reliable serial production lines is considered. A known aggregation method, given by Lim, Meerkov, and Top (1990, for the performance evaluation (i.e., estimation of throughput of this type of production lines when the buffer allocation is known, is used as an evaluative method in conjunction with a newly developed dynamic programming (DP algorithm for the BAP. The proposed algorithm is applied to production lines where the number of machines is varying from four up to a hundred machines. The proposed algorithm is fast because it reduces the volume of computations by rejecting allocations that do not lead to maximization of the line's throughput. Numerical results are also given for large production lines.

  5. Insights from the interim reliability evaluation program pertinent to reactor safety issues

    International Nuclear Information System (INIS)

    Carlson, D.D.

    1983-01-01

    The Interim Reliability Evaluation Program (IREP) consisted of concurrent probabilistic analyses of four operating nuclear power plants. This paper presents and integrated view of the results of the analyses drawing insights pertinent to reactor safety. The importance to risk of accident sequences initiated by transients and small loss-of-coolant accidents was confirmed. Support systems were found to contribute significantly to the sets of dominant accident sequences, either due to single failures which could disable one or more mitigating systems or due to their initiating plant transients. Human errors in response to accidents also were important risk contributors. Consideration of operator recovery actions influences accident sequence frequency estimates, the list of accident sequences dominating core melt, and the set of dominant risk contributors. Accidents involving station blackout, reactor coolant pump seal leaks and ruptures, and loss-of-coolant accidents requiring manual initiation of coolant injection were found to be risk significant

  6. Development of a Standardized Kalamazoo Communication Skills Assessment Tool for Radiologists: Validation, Multisource Reliability, and Lessons Learned.

    Science.gov (United States)

    Brown, Stephen D; Rider, Elizabeth A; Jamieson, Katherine; Meyer, Elaine C; Callahan, Michael J; DeBenedectis, Carolynn M; Bixby, Sarah D; Walters, Michele; Forman, Sara F; Varrin, Pamela H; Forbes, Peter; Roussin, Christopher J

    2017-08-01

    The purpose of this study was to develop and test a standardized communication skills assessment instrument for radiology. The Delphi method was used to validate the Kalamazoo Communication Skills Assessment instrument for radiology by revising and achieving consensus on the 43 items of the preexisting instrument among an interdisciplinary team of experts consisting of five radiologists and four nonradiologists (two men, seven women). Reviewers assessed the applicability of the instrument to evaluation of conversations between radiology trainees and trained actors portraying concerned parents in enactments about bad news, radiation risks, and diagnostic errors that were video recorded during a communication workshop. Interrater reliability was assessed by use of the revised instrument to rate a series of enactments between trainees and actors video recorded in a hospital-based simulator center. Eight raters evaluated each of seven different video-recorded interactions between physicians and parent-actors. The final instrument contained 43 items. After three review rounds, 42 of 43 (98%) items had an average rating of relevant or very relevant for bad news conversations. All items were rated as relevant or very relevant for conversations about error disclosure and radiation risk. Reliability and rater agreement measures were moderate. The intraclass correlation coefficient range was 0.07-0.58; mean, 0.30; SD, 0.13; and median, 0.30. The range of weighted kappa values was 0.03-0.47; mean, 0.23; SD, 0.12; and median, 0.22. Ratings varied significantly among conversations (χ 2 6 = 1186; p communication skills assessment instrument is highly relevant for radiology, having moderate interrater reliability. These findings have important implications for assessing the relational competencies of radiology trainees.

  7. Reliability constrained decision model for energy service provider incorporating demand response programs

    International Nuclear Information System (INIS)

    Mahboubi-Moghaddam, Esmaeil; Nayeripour, Majid; Aghaei, Jamshid

    2016-01-01

    Highlights: • The operation of Energy Service Providers (ESPs) in electricity markets is modeled. • Demand response as the cost-effective solution is used for energy service provider. • The market price uncertainty is modeled using the robust optimization technique. • The reliability of the distribution network is embedded into the framework. • The simulation results demonstrate the benefits of robust framework for ESPs. - Abstract: Demand response (DR) programs are becoming a critical concept for the efficiency of current electric power industries. Therefore, its various capabilities and barriers have to be investigated. In this paper, an effective decision model is presented for the strategic behavior of energy service providers (ESPs) to demonstrate how to participate in the day-ahead electricity market and how to allocate demand in the smart distribution network. Since market price affects DR and vice versa, a new two-step sequential framework is proposed, in which unit commitment problem (UC) is solved to forecast the expected locational marginal prices (LMPs), and successively DR program is applied to optimize the total cost of providing energy for the distribution network customers. This total cost includes the cost of purchased power from the market and distributed generation (DG) units, incentive cost paid to the customers, and compensation cost of power interruptions. To obtain compensation cost, the reliability evaluation of the distribution network is embedded into the framework using some innovative constraints. Furthermore, to consider the unexpected behaviors of the other market participants, the LMP prices are modeled as the uncertainty parameters using the robust optimization technique, which is more practical compared to the conventional stochastic approach. The simulation results demonstrate the significant benefits of the presented framework for the strategic performance of ESPs.

  8. Systems analysis programs for hands-on integrated reliability evaluations (SAPHIRE) version 5.0

    International Nuclear Information System (INIS)

    Russell, K.D.; Kvarfordt, K.J.; Skinner, N.L.; Wood, S.T.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. This volume is the reference manual for the Systems Analysis and Risk Assessment (SARA) System Version 5.0, a microcomputer-based system used to analyze the safety issues of a open-quotes familyclose quotes [i.e., a power plant, a manufacturing facility, any facility on which a probabilistic risk assessment (PRA) might be performed]. The SARA database contains PRA data primarily for the dominant accident sequences of a family and descriptive information about the family including event trees, fault trees, and system model diagrams. The number of facility databases that can be accessed is limited only by the amount of disk storage available. To simulate changes to family systems, SARA users change the failure rates of initiating and basic events and/or modify the structure of the cut sets that make up the event trees, fault trees, and systems. The user then evaluates the effects of these changes through the recalculation of the resultant accident sequence probabilities and importance measures. The results are displayed in tables and graphs that may be printed for reports. A preliminary version of the SARA program was completed in August 1985 and has undergone several updates in response to user suggestions and to maintain compatibility with the other SAPHIRE programs. Version 5.0 of SARA provides the same capability as earlier versions and adds the ability to process unlimited cut sets; display fire, flood, and seismic data; and perform more powerful cut set editing

  9. Teaching communication skills in clinical settings: comparing two applications of a comprehensive program with standardized and real patients.

    Science.gov (United States)

    Carvalho, Irene P; Pais, Vanessa G; Silva, Filipa R; Martins, Raquel; Figueiredo-Braga, Margarida; Pedrosa, Raquel; Almeida, Susana S; Correia, Luís; Ribeiro-Silva, Raquel; Castro-Vale, Ivone; Teles, Ana; Mota-Cardoso, Rui

    2014-05-09

    Communication is important for the quality of clinical practice, and programs have been implemented to improve healthcare providers' communication skills. However, the consistency of programs teaching communication skills has received little attention, and debate exists about the application of acquired skills to real patients. This study inspects whether (1) results from a communication program are replicated with different samples, and (2) results with standardized patients apply to interviews with real patients. A structured, nine-month communication program was applied in two consecutive years to two different samples of healthcare professionals (25 in the first year, 20 in the second year). Results were assessed at four different points in time, each year, regarding participants' confidence levels (self-rated), basic communication skills in interviews with standardized patients, and basic communication skills in interviews with real patients. Data were analyzed using GLM Repeated-Measures procedures. Improvements were statistically significant in both years in all measures except in simulated patients' assessment of the 2008 group. Differences between the two samples were non-significant. Differences between interviews with standardized and with real patients were also non-significant. The program's positive outcomes were replicated in different samples, and acquired skills were successfully applied to real-patient interviews. This reinforces this type of program structure as a valuable training tool, with results translating into real situations. It also adds to the reliability of the assessment instruments employed, though these may need adaptation in the case of real patients.

  10. Development of Standards for Textiles and Clothing Postsecondary Programs. Final Report.

    Science.gov (United States)

    Iowa State Univ. of Science and Technology, Ames. Dept. of Home Economics Education.

    A project was conducted to validate program standards and performance standards for four postsecondary occupational areas--fashion merchandising, fashion design, apparel, and window treatment services. Returns from 117 questionnaires from postsecondary institutions in fifty states were used to develop program standards statements and to provide…

  11. 24 CFR 200.950 - Building product standards and certification program for solar water heating system.

    Science.gov (United States)

    2010-04-01

    ... PROGRAMS Minimum Property Standards § 200.950 Building product standards and certification program for...) concerning labeling of a product, the administrator's validation mark and the manufacturer's certification of... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Building product standards and...

  12. 24 CFR 200.948 - Building product standards and certification program for carpet cushion.

    Science.gov (United States)

    2010-04-01

    ... Minimum Property Standards § 200.948 Building product standards and certification program for carpet... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Building product standards and certification program for carpet cushion. 200.948 Section 200.948 Housing and Urban Development Regulations...

  13. 78 FR 73589 - Energy Conservation Program: Energy Conservation Standards for Commercial and Industrial Electric...

    Science.gov (United States)

    2013-12-06

    ... Conservation Program: Energy Conservation Standards for Commercial and Industrial Electric Motors; Proposed... Conservation Program: Energy Conservation Standards for Commercial and Industrial Electric Motors AGENCY... proposes energy conservation standards for a number of different groups of electric motors that DOE has not...

  14. Standardized Testing Program for Solid-State Hydrogen Storage Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Michael A. [Southwest Research Institute; Page, Richard A. [Southwest Research Institute

    2012-07-30

    In the US and abroad, major research and development initiatives toward establishing a hydrogen-based transportation infrastructure have been undertaken, encompassing key technological challenges in hydrogen production and delivery, fuel cells, and hydrogen storage. However, the principal obstacle to the implementation of a safe, low-pressure hydrogen fueling system for fuel-cell powered vehicles remains storage under conditions of near-ambient temperature and moderate pressure. The choices for viable hydrogen storage systems at the present time are limited to compressed gas storage tanks, cryogenic liquid hydrogen storage tanks, chemical hydrogen storage, and hydrogen absorbed or adsorbed in a solid-state material (a.k.a. solid-state storage). Solid-state hydrogen storage may offer overriding benefits in terms of storage capacity, kinetics and, most importantly, safety.The fervor among the research community to develop novel storage materials had, in many instances, the unfortunate consequence of making erroneous, if not wild, claims on the reported storage capacities achievable in such materials, to the extent that the potential viability of emerging materials was difficult to assess. This problem led to a widespread need to establish a capability to accurately and independently assess the storage behavior of a wide array of different classes of solid-state storage materials, employing qualified methods, thus allowing development efforts to focus on those materials that showed the most promise. However, standard guidelines, dedicated facilities, or certification programs specifically aimed at testing and assessing the performance, safety, and life cycle of these emergent materials had not been established. To address the stated need, the Testing Laboratory for Solid-State Hydrogen Storage Technologies was commissioned as a national-level focal point for evaluating new materials emerging from the designated Materials Centers of Excellence (MCoE) according to

  15. Reliability evaluation of high-performance, low-power FinFET standard cells based on mixed RBB/FBB technique

    Science.gov (United States)

    Wang, Tian; Cui, Xiaoxin; Ni, Yewen; Liao, Kai; Liao, Nan; Yu, Dunshan; Cui, Xiaole

    2017-04-01

    With shrinking transistor feature size, the fin-type field-effect transistor (FinFET) has become the most promising option in low-power circuit design due to its superior capability to suppress leakage. To support the VLSI digital system flow based on logic synthesis, we have designed an optimized high-performance low-power FinFET standard cell library based on employing the mixed FBB/RBB technique in the existing stacked structure of each cell. This paper presents the reliability evaluation of the optimized cells under process and operating environment variations based on Monte Carlo analysis. The variations are modelled with Gaussian distribution of the device parameters and 10000 sweeps are conducted in the simulation to obtain the statistical properties of the worst-case delay and input-dependent leakage for each cell. For comparison, a set of non-optimal cells that adopt the same topology without employing the mixed biasing technique is also generated. Experimental results show that the optimized cells achieve standard deviation reduction of 39.1% and 30.7% at most in worst-case delay and input-dependent leakage respectively while the normalized deviation shrinking in worst-case delay and input-dependent leakage can be up to 98.37% and 24.13%, respectively, which demonstrates that our optimized cells are less sensitive to variability and exhibit more reliability. Project supported by the National Natural Science Foundation of China (No. 61306040), the State Key Development Program for Basic Research of China (No. 2015CB057201), the Beijing Natural Science Foundation (No. 4152020), and Natural Science Foundation of Guangdong Province, China (No. 2015A030313147).

  16. Testing Standard Reliability Criteria

    Science.gov (United States)

    Sherry, David

    2017-01-01

    Maul's paper, "Rethinking Traditional Methods of Survey Validation" (Andrew Maul), contains two stages. First he presents empirical results that cast doubt on traditional methods for validating psychological measurement instruments. These results motivate the second stage, a critique of current conceptions of psychological measurement…

  17. QA support for TFTR reliability improvement program in preparation for DT operation

    International Nuclear Information System (INIS)

    Parsells, R.F.; Howard, H.P.

    1987-01-01

    As TFTR approaches experiments in the Q=1 regime, machine reliability becomes a major variable in achieving experimental objectives. This paper describes the methods used to quantify current reliability levels, levels required for D-T operations, proposed methods for reliability growth and improvement, and tracking of reliability performance in that growth. Included in this scope are data collection techniques and short comings, bounding current reliability on the upper end, and requirements for D-T operations. Problem characterization through Pareto diagrams provides insight into recurrent failure modes and the use of Duane plots for charting of reliability changes both cumulative and instantaneous, is explained and demonstrated

  18. Factors that influence standard automated perimetry test results in glaucoma: test reliability, technician experience, time of day, and season.

    Science.gov (United States)

    Junoy Montolio, Francisco G; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M

    2012-10-09

    To determine the influence of several factors on standard automated perimetry test results in glaucoma. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience, time of day, and season on the mean deviation (MD) was determined by performing linear regression analysis of MD against time on a series of visual fields and subsequently performing a multiple linear regression analysis with the MD residuals as dependent variable and the factors mentioned above as independent variables. Analyses were performed with and without adjustment for the test reliability (fixation losses and false-positive and false-negative answers) and with and without stratification according to disease stage (baseline MD). Mean follow-up was 9.4 years, with on average 10.8 tests per patient. Technician experience, time of day, and season were associated with the MD. Approximately 0.2 dB lower MD values were found for inexperienced technicians (P Technician experience, time of day, season, and the percentage of false-positive answers have a significant influence on the MD of standard automated perimetry.

  19. Review of the Commission program for standardization of nuclear power plants and recommendations to improve standardization concepts

    International Nuclear Information System (INIS)

    1978-02-01

    This is a report of a staff study describing the need and utility of specific changes to the Commission's standardization program. The various matters considered in the study include: (1) A discussion of industry use to date of the standardization program. (2) A discussion of the experience to date with each of the standardization concepts. (3) A review of public comments on the standardization program and the staff response to each principal comment. (4) A review of the need for standardization considering the likely number of license applications to be submitted in the coming years. (5) A discussion of the reference system concept, including review of applicable experience and recommended changes to the concept. (6) A discussion of the duplicate plant concept, including review of applicable experience and recommended changes to the concept. (7) A discussion of the manufacturing license concept, including review of applicable experience and recommended changes to the concept. (8) A discussion of the replicate plant concept, including review of applicable experience and recommended changes to the concept. (9) A discussion of the effective periods for approved designs under all four standardization concepts. (10) A description of continuing staff activities related to the standardization program

  20. Space Shuttle Program Primary Avionics Software System (PASS) Success Legacy - Quality and Reliability Date

    Science.gov (United States)

    Orr, James K.; Peltier, Daryl

    2010-01-01

    Thsi slide presentation reviews the avionics software system on board the space shuttle, with particular emphasis on the quality and reliability. The Primary Avionics Software System (PASS) provides automatic and fly-by-wire control of critical shuttle systems which executes in redundant computers. Charts given show the number of space shuttle flights vs time, PASS's development history, and other charts that point to the reliability of the system's development. The reliability of the system is also compared to predicted reliability.

  1. ETV Program Report: Coatings for Wastewater Collection Systems - Standard Cement Materials, Epoxy Coating 4553

    Science.gov (United States)

    The Standard Cement Materials, Inc. Standard Epoxy Coating 4553™ (SEC 4553) epoxy coating used for wastewater collection system rehabilitation was evaluated by EPA’s Environmental Technology Verification Program under laboratory conditions at the Center for Innovative Grouting Ma...

  2. 24 CFR 200.947 - Building product standards and certification program for polystyrene foam insulation board.

    Science.gov (United States)

    2010-04-01

    ... INTRODUCTION TO FHA PROGRAMS Minimum Property Standards § 200.947 Building product standards and certification... product, the administrator's certification of compliance with the applicable standards and the type of... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Building product standards and...

  3. Teaching communication skills in clinical settings: comparing two applications of a comprehensive program with standardized and real patients

    Science.gov (United States)

    2014-01-01

    Background Communication is important for the quality of clinical practice, and programs have been implemented to improve healthcare providers’ communication skills. However, the consistency of programs teaching communication skills has received little attention, and debate exists about the application of acquired skills to real patients. This study inspects whether (1) results from a communication program are replicated with different samples, and (2) results with standardized patients apply to interviews with real patients. Methods A structured, nine-month communication program was applied in two consecutive years to two different samples of healthcare professionals (25 in the first year, 20 in the second year). Results were assessed at four different points in time, each year, regarding participants’ confidence levels (self-rated), basic communication skills in interviews with standardized patients, and basic communication skills in interviews with real patients. Data were analyzed using GLM Repeated-Measures procedures. Results Improvements were statistically significant in both years in all measures except in simulated patients’ assessment of the 2008 group. Differences between the two samples were non-significant. Differences between interviews with standardized and with real patients were also non-significant. Conclusions The program’s positive outcomes were replicated in different samples, and acquired skills were successfully applied to real-patient interviews. This reinforces this type of program structure as a valuable training tool, with results translating into real situations. It also adds to the reliability of the assessment instruments employed, though these may need adaptation in the case of real patients. PMID:24886341

  4. Defense Standardization Program Journal. October/December 2012

    Science.gov (United States)

    2012-10-01

    Barriers to Trade ( TBT ).The WTO TBT agreement establishes principles for interna- tional standardization processes using attributes similar to those...WTO TBT agreement, the proposed standardization regulation states that public authorities should make best use of the full range of relevant

  5. A Linear Programming Reformulation of the Standard Quadratic Optimization Problem

    NARCIS (Netherlands)

    de Klerk, E.; Pasechnik, D.V.

    2005-01-01

    The problem of minimizing a quadratic form over the standard simplex is known as the standard quadratic optimization problem (SQO).It is NPhard, and contains the maximum stable set problem in graphs as a special case.In this note we show that the SQO problem may be reformulated as an (exponentially

  6. Improvements in valve reliability due to implementation of effective condition monitoring programs

    International Nuclear Information System (INIS)

    Hale, Stan

    2003-01-01

    Modern diagnostic systems for motor-operated valves, pneumatic control valves and checkvalves have facilitated a shift in the maintenance philosophy for valves and actuators in nuclear power plants from schedule based to condition-based maintenance (CBM). This shift enables plant management to focus resources and schedule priority on the plant equipment that warrants attention thereby not wasting resources or increasing the human factors risk on equipment that has not degraded. The most recent initiatives combine condition monitoring with risk/safety insights to focus attention and resonances on the right equipment at the right time consistent with each component's safety-significance. The activities of the ASME working groups responsible for nuclear O and M codes have kept pace with the technology and process improvements necessary to maximize the technical and economic benefits of condition based and risk informed maintenance. This paper discusses adoption of valve condition monitoring in the nuclear power industry, changes to ASME codes and standards during the 90's to facilitate adoption of condition monitoring technology for in-service testing and recent efforts to combine risk insights with condition monitoring strategies to achieve the highest level of valve reliability and nuclear safety without over inflating maintenance cost. (author)

  7. 76 FR 77999 - Standardizing Program Reporting Requirements for Broadcast Licensees

    Science.gov (United States)

    2011-12-15

    ... concerns, and in view of advances in technology and the revisions to the form we discuss here, should not... within each news program, i.e. the length of each story? How should the term ``program segment'' be... reporting, since some stories reported on the local news are more national in character, and would not fit...

  8. 38 CFR 1.15 - Standards for program evaluation.

    Science.gov (United States)

    2010-07-01

    ... program operates. (3) Validity. The degree of statistical validity should be assessed within the research... intent, contain a method to measure fulfillment of the objectives, ascertain the degree to which goals... the data. (f) Each program evaluation requires a systematic research design to collect the data...

  9. Results of the reliability benchmark exercise and the future CEC-JRC program

    International Nuclear Information System (INIS)

    Amendola, A.

    1985-01-01

    As a contribution towards identifying problem areas and for assessing probabilistic safety assessment (PSA) methods and procedures of analysis, JRC has organized a wide-range Benchmark Exercise on systems reliability. This has been executed by ten different teams involving seventeen organizations from nine European countries. The exercise has been based on a real case (Auxiliary Feedwater System of EDF Paluel PWR 1300 MWe Unit), starting from analysis of technical specifications, logical and topological layout and operational procedures. Terms of references included both qualitative and quantitative analyses. The subdivision of the exercise into different phases and the rules adopted allowed assessment of the different components of the spread of the overall results. It appeared that modelling uncertainties may overwhelm data uncertainties and major efforts must be spent in order to improve consistency and completeness of qualitative analysis. After successful completion of the first exercise, CEC-JRC program has planned separate exercises on analysis of dependent failures and human factors before approaching the evaluation of a complete accident sequence

  10. Asymmetric Programming: A Highly Reliable Metadata Allocation Strategy for MLC NAND Flash Memory-Based Sensor Systems

    Science.gov (United States)

    Huang, Min; Liu, Zhaoqing; Qiao, Liyan

    2014-01-01

    While the NAND flash memory is widely used as the storage medium in modern sensor systems, the aggressive shrinking of process geometry and an increase in the number of bits stored in each memory cell will inevitably degrade the reliability of NAND flash memory. In particular, it's critical to enhance metadata reliability, which occupies only a small portion of the storage space, but maintains the critical information of the file system and the address translations of the storage system. Metadata damage will cause the system to crash or a large amount of data to be lost. This paper presents Asymmetric Programming, a highly reliable metadata allocation strategy for MLC NAND flash memory storage systems. Our technique exploits for the first time the property of the multi-page architecture of MLC NAND flash memory to improve the reliability of metadata. The basic idea is to keep metadata in most significant bit (MSB) pages which are more reliable than least significant bit (LSB) pages. Thus, we can achieve relatively low bit error rates for metadata. Based on this idea, we propose two strategies to optimize address mapping and garbage collection. We have implemented Asymmetric Programming on a real hardware platform. The experimental results show that Asymmetric Programming can achieve a reduction in the number of page errors of up to 99.05% with the baseline error correction scheme. PMID:25310473

  11. Asymmetric Programming: A Highly Reliable Metadata Allocation Strategy for MLC NAND Flash Memory-Based Sensor Systems

    Directory of Open Access Journals (Sweden)

    Min Huang

    2014-10-01

    Full Text Available While the NAND flash memory is widely used as the storage medium in modern sensor systems, the aggressive shrinking of process geometry and an increase in the number of bits stored in each memory cell will inevitably degrade the reliability of NAND flash memory. In particular, it’s critical to enhance metadata reliability, which occupies only a small portion of the storage space, but maintains the critical information of the file system and the address translations of the storage system. Metadata damage will cause the system to crash or a large amount of data to be lost. This paper presents Asymmetric Programming, a highly reliable metadata allocation strategy for MLC NAND flash memory storage systems. Our technique exploits for the first time the property of the multi-page architecture of MLC NAND flash memory to improve the reliability of metadata. The basic idea is to keep metadata in most significant bit (MSB pages which are more reliable than least significant bit (LSB pages. Thus, we can achieve relatively low bit error rates for metadata. Based on this idea, we propose two strategies to optimize address mapping and garbage collection. We have implemented Asymmetric Programming on a real hardware platform. The experimental results show that Asymmetric Programming can achieve a reduction in the number of page errors of up to 99.05% with the baseline error correction scheme.

  12. Defense Standardization Program Journal. October/December 2011

    Science.gov (United States)

    2011-12-01

    Trade Organization (WTO) Committee on Technical Bar- riers to Trade ( TBT ),’ they are less likely to create unnecessary barriers to trade. International...standards can also increase efficiency, enhance the quality of life and transfer technology from developed to developing countries. The TBT ...its commitment to the TBT principles for the development of international stan- dards2 and the Code of Good Practice.1 The U.S.—based standardization

  13. Defense Standardization Program Journal. April/September 2012

    Science.gov (United States)

    2012-01-01

    were magnified. In 1905, a committee of the National Fire Protection Association established a national standard for the diameter and threads per inch...for fire hydrants and hose couplings. The standard specifies that fire hydrants have 2.5-inch hose connections with 7.5 threads per inch and that...dsp.dla.mil I Field of view, lens material haze, luminous transmittance, and lens abrasion resistance (APR) I Communications (APR) I Fogging (APR

  14. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Code Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    C. L. Smith; K. J. Kvarfordt; S. T. Wood

    2008-08-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer. SAPHIRE is funded by the U.S. Nuclear Regulatory Commission (NRC) and developed by the Idaho National Laboratory (INL). The INL's primary role in this project is that of software developer. However, the INL also plays an important role in technology transfer by interfacing and supporting SAPHIRE users comprised of a wide range of PRA practitioners from the NRC, national laboratories, the private sector, and foreign countries. SAPHIRE can be used to model a complex system’s response to initiating events, quantify associated damage outcome frequencies, and identify important contributors to this damage (Level 1 PRA) and to analyze containment performance during a severe accident and quantify radioactive releases (Level 2 PRA). It can be used for a PRA evaluating a variety of operating conditions, for example, for a nuclear reactor at full power, low power, or at shutdown conditions. Furthermore, SAPHIRE can be used to analyze both internal and external initiating events and has special features for transforming models built for internal event analysis to models for external event analysis. It can also be used in a limited manner to quantify risk in terms of release consequences to both the public and the environment (Level 3 PRA). SAPHIRE includes a separate module called the Graphical Evaluation Module (GEM). GEM provides a highly specialized user interface with SAPHIRE that automates SAPHIRE process steps for evaluating operational events at commercial nuclear power plants. Using GEM, an analyst can estimate the risk associated with operational events in a very efficient and expeditious manner. This reference guide will introduce the SAPHIRE Version 7.0 software. A brief discussion of the purpose and history of the software is included along with

  15. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Code Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    C. L. Smith; K. J. Kvarfordt; S. T. Wood

    2006-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer. SAPHIRE is funded by the U.S. Nuclear Regulatory Commission (NRC) and developed by the Idaho National Laboratory (INL). The INL's primary role in this project is that of software developer. However, the INL also plays an important role in technology transfer by interfacing and supporting SAPHIRE users comprised of a wide range of PRA practitioners from the NRC, national laboratories, the private sector, and foreign countries. SAPHIRE can be used to model a complex system’s response to initiating events, quantify associated damage outcome frequencies, and identify important contributors to this damage (Level 1 PRA) and to analyze containment performance during a severe accident and quantify radioactive releases (Level 2 PRA). It can be used for a PRA evaluating a variety of operating conditions, for example, for a nuclear reactor at full power, low power, or at shutdown conditions. Furthermore, SAPHIRE can be used to analyze both internal and external initiating events and has special features for ansforming models built for internal event analysis to models for external event analysis. It can also be used in a limited manner to quantify risk in terms of release consequences to both the public and the environment (Level 3 PRA). SAPHIRE includes a separate module called the Graphical Evaluation Module (GEM). GEM provides a highly specialized user interface with SAPHIRE that automates SAPHIRE process steps for evaluating operational events at commercial nuclear power plants. Using GEM, an analyst can estimate the risk associated with operational events in a very efficient and expeditious manner. This reference guide will introduce the SAPHIRE Version 7.0 software. A brief discussion of the purpose and history of the software is included along with

  16. The role of the American Society for Testing and Materials (ASTM) in providing standards to support reliability technology for nuclear power plants

    International Nuclear Information System (INIS)

    Steele, L.E.

    1978-01-01

    ASTM is an international society for managing the development of standards on characteristics and performance of materials, products, systems and services and the promotion of related knowledge. This paper provides on overview of ASTM, emphasizing its contribution to nuclear systems reliability. In so doing, the author, from his perspective as chairman of ASTM committee E 10 on ''Nuclear Applications and the Measurement of Radiation Effects and the Committee on Standards'', illustrates ASTM contributions to the understanding and control of radiation embrittlement of light-water reactor pressure vessels. Four major related taks are summarized and pertinent standards identified. These include: (1) surveillance practice (5 standards), (2) neutron dosimetry (8 standards), (3) specification for steels for nuclear service (7 standards) and (4) basic guidelines for thermal annealing to correct radiation embrittlement (1 standard). This illustration, a specific accomplishment using ASTM standards, is cited within the context of the broader nuclear-related activities of ASTM. (author)

  17. Standard Guide for Radiation Protection Program for Decommissioning Operations

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1987-01-01

    1.1 This guide provides instruction to the individual charged with the responsibility for developing and implementing the radiation protection program for decommissioning operations. 1.2 This guide provides a basis for the user to develop radiation protection program documentation that will support both the radiological engineering and radiation safety aspects of the decommissioning project. 1.3 This guide presents a description of those elements that should be addressed in a specific radiation protection plan for each decommissioning project. The plan would, in turn, form the basis for development of the implementation procedures that execute the intent of the plan. 1.4 This guide applies to the development of radiation protection programs established to control exposures to radiation and radioactive materials associated with the decommissioning of nuclear facilities. The intent of this guide is to supplement existing radiation protection programs as they may pertain to decommissioning workers, members of...

  18. Related Rules and Programs that Help States Attain PM Standards

    Science.gov (United States)

    EPA’s national and regional rules to reduce emissions of pollutants that form particle pollution will help state and local governments meet the PM NAAQS. A number of voluntary programs also are helping areas reduce fine PM pollution.

  19. The USCG/environment Canada/ASTM standards development program

    International Nuclear Information System (INIS)

    Whittaker, H.

    1992-01-01

    Environment Canada's Emergencies Engineering Division (EED) has been charged, as a result of the Public Review Panel on Tanker Safety and Marine Emergency Response report, with increased R ampersand D in marine oil spills. This activity will, of necessity, include development of standards and guidelines for the testing and/or usage of oil spill cleanup equipment. The United States Coast Guard (USCG) has been charged with implementing the provisions of the Oil Pollution Act of 1990 (OPA-90), as it pertains to marine transportation vessels and facilities. Among the provisions are requirements for vessel and facility owners and operators to develop comprehensive response plans that specifically match response resources to spill removal requirements. Meeting the response plan provisions of OPA-90 requires common standards for testing, selecting and assigning resources to anticipated response needs and objectively evaluating response plans for adequacy. In August of 1991, the USCG OPA-90 office approached ASTM to determine the feasibility of developing standards through that organizations procedures. Meetings were then held between the OPA-90 staff and members of the ASTM Committee F-20 on Hazardous Substances and Oil Spill Response. An agreement was reached to commence standards development in the areas of: Barriers, Skimmers, Treating Agents, Pumps, Beach Clean-up, Sorbents, Bioremediation, In-situ Burning, Temporary Storage Devices, Communications, Remote Sensing. It was recognized that ASTM and other organizational standards existed in several of these areas, but there were those where none were known to exist. Standards development was, therefore, expected to be a complicated and time-consuming process. Both the USCG OPA-90 and EC/EED offices required standards to be developed quickly, without subverting the ASTM process. Mechanical containment and recovery was considered to be the primary area of concern for both groups

  20. Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program

    Science.gov (United States)

    Sled, Elizabeth A.; Sheehy, Lisa M.; Felson, David T.; Costigan, Patrick A.; Lam, Miu; Cooke, T. Derek V.

    2010-01-01

    The objective of the study was to evaluate the reliability of frontal plane lower limb alignment measures using a landmark-based method by (1) comparing inter- and intra-reader reliability between measurements of alignment obtained manually with those using a computer program, and (2) determining inter- and intra-reader reliability of computer-assisted alignment measures from full-limb radiographs. An established method for measuring alignment was used, involving selection of 10 femoral and tibial bone landmarks. 1) To compare manual and computer methods, we used digital images and matching paper copies of five alignment patterns simulating healthy and malaligned limbs drawn using AutoCAD. Seven readers were trained in each system. Paper copies were measured manually and repeat measurements were performed daily for 3 days, followed by a similar routine with the digital images using the computer. 2) To examine the reliability of computer-assisted measures from full-limb radiographs, 100 images (200 limbs) were selected as a random sample from 1,500 full-limb digital radiographs which were part of the Multicenter Osteoarthritis (MOST) Study. Three trained readers used the software program to measure alignment twice from the batch of 100 images, with two or more weeks between batch handling. Manual and computer measures of alignment showed excellent agreement (intraclass correlations [ICCs] 0.977 – 0.999 for computer analysis; 0.820 – 0.995 for manual measures). The computer program applied to full-limb radiographs produced alignment measurements with high inter- and intra-reader reliability (ICCs 0.839 – 0.998). In conclusion, alignment measures using a bone landmark-based approach and a computer program were highly reliable between multiple readers. PMID:19882339

  1. Reliability Calculations

    DEFF Research Database (Denmark)

    Petersen, Kurt Erling

    1986-01-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety...... and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic...... approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very...

  2. Perform qualify reliability-power tests by shooting common mistakes: practical problems and standard answers per Telcordia/Bellcore requests

    Science.gov (United States)

    Yu, Zheng

    2002-08-01

    Facing the new demands of the optical fiber communications market, almost all the performance and reliability of optical network system are dependent on the qualification of the fiber optics components. So, how to comply with the system requirements, the Telcordia / Bellcore reliability and high-power testing has become the key issue for the fiber optics components manufacturers. The qualification of Telcordia / Bellcore reliability or high-power testing is a crucial issue for the manufacturers. It is relating to who is the outstanding one in the intense competition market. These testing also need maintenances and optimizations. Now, work on the reliability and high-power testing have become the new demands in the market. The way is needed to get the 'Triple-Win' goal expected by the component-makers, the reliability-testers and the system-users. To those who are meeting practical problems for the testing, there are following seven topics that deal with how to shoot the common mistakes to perform qualify reliability and high-power testing: ¸ Qualification maintenance requirements for the reliability testing ¸ Lots control for preparing the reliability testing ¸ Sampling select per the reliability testing ¸ Interim measurements during the reliability testing ¸ Basic referencing factors relating to the high-power testing ¸ Necessity of re-qualification testing for the changing of producing ¸ Understanding the similarity for product family by the definitions

  3. Standard interfaces for program-modular multiprocessor systems

    International Nuclear Information System (INIS)

    Chernykh, E.V.

    1982-01-01

    The peculiarities of the structures of existing and developed standard interfaces used in automation systems for nuclear physical experiments are considered. general structural characteristics of multiprocessor system interfaces are revealed. The comparison of the existing system CAMAC crate and designed standards of COMPEX, E3S and FASTBUS interfaces by capacity and relative cost is carried out. The analysis of the given data shows that operation of any interface is more advantageous at the rates close to capacity values, the relative cost being minimum. In this case the advantage is on the side of interfaces with greater capacity values for which at a moderated decrease of the exchange or requests processing rate the relative costs grow slower. A higher capacity of one-cycle exchange is provided with functional data way specialization in the interface. The conclusion is drawn that most perspective trend in the development of automation systems for high energy physics experiments is using FASTBUS standard

  4. Evaluation of four building energy analysis computer programs against ASHRAE standard 140-2007

    CSIR Research Space (South Africa)

    Szewczuk, S

    2014-08-01

    Full Text Available ) standard or code of practice. Agrément requested the CSIR to evaluate a range of building energy simulation computer programs. The standard against which these computer programs were to be evaluated was developed by the American Society of Heating...

  5. Cartographic standards to improve maps produced by the Forest Inventory and Analysis program

    Science.gov (United States)

    Charles H. (Hobie) Perry; Mark D. Nelson

    2009-01-01

    The Forest Service, U.S. Department of Agriculture's Forest Inventory and Analysis (FIA) program is incorporating an increasing number of cartographic products in reports, publications, and presentations. To create greater quality and consistency within the national FIA program, a Geospatial Standards team developed cartographic design standards for FIA map...

  6. Defense Standardization Program Journal. January-March 2012

    Science.gov (United States)

    2012-03-01

    example, the team added standardized qualification and performance verification procedures, such as edge-reten- tion verification, cathodic disbondment...edge retention. In addition, they incorporated cathodic disbondment tests used to verify the performance of pipeline coatings into the specification...pure electrodeposited aluminum—were identified as being suitable plating finishing options for replacing cadmium. DLA Land and Maritime added these

  7. 76 FR 11502 - Notice of Vitamin D Standardization Program

    Science.gov (United States)

    2011-03-02

    ... that can be used for calibration and trueness control by laboratories measuring 25(OH)D. These... done in national health surveys, it also allows for participation of clinical, public health, research and commercial laboratories and commercial trade organizations in the standardization effort. FOR...

  8. Research Review: Test-retest reliability of standardized diagnostic interviews to assess child and adolescent psychiatric disorders: a systematic review and meta-analysis.

    Science.gov (United States)

    Duncan, Laura; Comeau, Jinette; Wang, Li; Vitoroulis, Irene; Boyle, Michael H; Bennett, Kathryn

    2018-02-19

    A better understanding of factors contributing to the observed variability in estimates of test-retest reliability in published studies on standardized diagnostic interviews (SDI) is needed. The objectives of this systematic review and meta-analysis were to estimate the pooled test-retest reliability for parent and youth assessments of seven common disorders, and to examine sources of between-study heterogeneity in reliability. Following a systematic review of the literature, multilevel random effects meta-analyses were used to analyse 202 reliability estimates (Cohen's kappa = ҡ) from 31 eligible studies and 5,369 assessments of 3,344 children and youth. Pooled reliability was moderate at ҡ = .58 (CI 95% 0.53-0.63) and between-study heterogeneity was substantial (Q = 2,063 (df = 201), p reliability varied across informants for specific types of psychiatric disorder (ҡ = .53-.69 for parent vs. ҡ = .39-.68 for youth) with estimates significantly higher for parents on attention deficit hyperactivity disorder, oppositional defiant disorder and the broad groupings of externalizing and any disorder. Reliability was also significantly higher in studies with indicators of poor or fair study methodology quality (sample size reliability of SDIs and the usefulness of these tools in both clinical and research contexts. Potential remedies include the introduction of standardized study and reporting requirements for reliability studies, and exploration of other approaches to assessing and classifying child and adolescent psychiatric disorder. © 2018 Association for Child and Adolescent Mental Health.

  9. Reliability of instruments in a cooperative, multisite study: employment intervention demonstration program.

    Science.gov (United States)

    Salyers, M P; McHugo, G J; Cook, J A; Razzano, L A; Drake, R E; Mueser, K T

    2001-09-01

    Reliability of well-known instruments was examined in 202 people with severe mental illness participating in a multisite vocational study. We examined interrater reliability of the Positive and Negative Syndrome Scale (PANSS) and the internal consistency and test-retest reliability of the PANSS, the Rosenberg Self-Esteem Scale, the Medical Outcomes Study Short Form-36 (SF-36), and the Quality of Life Interview. Most scales had good levels of reliability, with intraclass correlation coefficients (ICCs) and coefficient alphas above .70. However, the SF-36 scales were generally less stable over time, particularly Social Functioning (ICC = .55). Test-retest reliability was lower among less educated respondents and among ethnic minorities. We recommend close monitoring of psychometric issues in future multisite studies.

  10. Characterizing reliability in a product/process design-assurance program

    Energy Technology Data Exchange (ETDEWEB)

    Kerscher, W.J. III [Delphi Energy and Engine Management Systems, Flint, MI (United States); Booker, J.M.; Bement, T.R.; Meyer, M.A. [Los Alamos National Lab., NM (United States)

    1997-10-01

    Over the years many advancing techniques in the area of reliability engineering have surfaced in the military sphere of influence, and one of these techniques is Reliability Growth Testing (RGT). Private industry has reviewed RGT as part of the solution to their reliability concerns, but many practical considerations have slowed its implementation. It`s objective is to demonstrate the reliability requirement of a new product with a specified confidence. This paper speaks directly to that objective but discusses a somewhat different approach to achieving it. Rather than conducting testing as a continuum and developing statistical confidence bands around the results, this Bayesian updating approach starts with a reliability estimate characterized by large uncertainty and then proceeds to reduce the uncertainty by folding in fresh information in a Bayesian framework.

  11. National screening program vs. standardized neurodevelopmental follow-up

    NARCIS (Netherlands)

    Maschke, Cornelia; Ellenrieder, Birte; Hecher, Kurt; Bartmann, Peter

    Background: Long-term follow-up is urgently needed to decide on the consequences of new therapies. Objective: This study assesses the use of a national child development screening program for a follow-up examination of a defined patient group. Patients and methods: Neurodevelopmental outcome of 139

  12. Quality Assurance Plans under the Renewable Fuel Standard Program

    Science.gov (United States)

    Quality Assurance Plan or (QAP) is a voluntary program where independent third-parties may audit and verify that RINs have been properly generated and are valid for compliance purposes. RINs verified under a QAP may be purchased by regulated parties.

  13. A Revised Admissions Standard for One Community College Nursing Program

    Science.gov (United States)

    Lown, Maris A.

    2010-01-01

    Predicting success on the NCLEX-RN is of paramount importance to nursing programs as they are held accountable for this outcome by accrediting agencies and by boards of nursing. This action research study examined the relationship between the NET admission test, anatomy and physiology grades, grade point average (GPA) on admission to the program…

  14. 75 FR 17036 - Energy Conservation Program: Energy Conservation Standards for Small Electric Motors; Correction

    Science.gov (United States)

    2010-04-05

    ... Conservation Program: Energy Conservation Standards for Small Electric Motors; Correction AGENCY: Office of... standards for small electric motors, which was published on March 9, 2010. In that final rule, the U.S... titled ``Energy Conservation Standards for Small Electric Motors.'' 75 FR 10874. Since the publication of...

  15. 77 FR 59712 - Energy Conservation Program: Energy Conservation Standards for Dishwashers

    Science.gov (United States)

    2012-10-01

    ... amended energy conservation standards, DOE conducted a market survey using all available public... Energy Conservation Program: Energy Conservation Standards for Dishwashers AGENCY: Office of Energy... establish amended energy conservation standards for dishwashers in the Federal Register on May 30, 2012. DOE...

  16. RECOMMENDED FOUNDATION FILL MATERIALS CONSTRUCTION STANDARD OF THE FLORIDA RADON RESEARCH PROGRAM

    Science.gov (United States)

    The report summarizes the technical basis for a recommended foundation fill materials standard for new construction houses in Florida. he radon-control construction standard was developed by the Florida Radon Research Program (FRRP). ill material standards are formulated for: (1)...

  17. Defense Standardization Program Journal. April/June 2011

    Science.gov (United States)

    2011-06-01

    years, the seven winners have played an integral part in keeping our men and women in uniform sate and in providing them the tools they need to get...supporting our men and women in uniform, helping to multiply capability through interoperability, and saving money tor the taxpayer. 1 hope that reading...committee chair of ASTM B687, "Standard Specifi- cation for Brass, Copper, and Chromium-Plated Pipe Nipples " (FSC 4730), to incor- porate eight additional

  18. Global Potential of Energy Efficiency Standards and Labeling Programs

    Energy Technology Data Exchange (ETDEWEB)

    McNeil, Michael A; McNeil, Michael A.; Letschert, Virginie; de la Rue du Can, Stephane

    2008-06-15

    This report estimates the global potential reductions in greenhouse gas emissions by 2030 for energy efficiency improvements associated with equipment (appliances, lighting, and HVAC) in buildings by means of energy efficiency standards and labels (EES&L). A consensus has emerged among the world's scientists and many corporate and political leaders regarding the need to address the threat of climate change through emissions mitigation and adaptation. A further consensus has emerged that a central component of these strategies must be focused around energy, which is the primary generator of greenhouse gas emissions. Two important questions result from this consensus: 'what kinds of policies encourage the appropriate transformation to energy efficiency' and 'how much impact can these policies have'? This report aims to contribute to the dialogue surrounding these issues by considering the potential impacts of a single policy type, applied on a global scale. The policy addressed in this report is Energy Efficient Standards and Labeling (EES&L) for energy-consuming equipment, which has now been implemented in over 60 countries. Mandatory energy performance standards are important because they contribute positively to a nation's economy and provide relative certainty about the outcome (both timing and magnitudes). Labels also contribute positively to a nation's economy and importantly increase the awareness of the energy-consuming public. Other policies not analyzed here (utility incentives, tax credits) are complimentary to standards and labels and also contribute in significant ways to reducing greenhouse gas emissions. We believe the analysis reported here to be the first systematic attempt to evaluate the potential of savings from EES&L for all countries and for such a large set of products. The goal of the analysis is to provide an assessment that is sufficiently well-quantified and accurate to allow comparison and integration

  19. Defense Standardization Program Journal. October/December 2009.

    Science.gov (United States)

    2009-12-01

    Franchisee ! Distributor Contract Manufacturer Independent Distributor or Stocking Distributor g Highest Confidence in Authority Ewest...continued by suppliers. Although the FWG-IDR is focused on digital radiography, its work on data standardization and management will benefit all methods of...obtain funding to gain long-term benefits in periods of constrained funding. The most important task in technology migration is the identification

  20. Proposed Accreditation Standards for Degree-Granting Correspondence Programs Offered by Accredited Institutions.

    Science.gov (United States)

    McGraw-Hill Continuing Education Center, Washington, DC.

    A study on proposed accreditation standards grew out of a need to (1) stimulate the growth of quality correspondence degree programs; and (2) provide a policy for accreditation of correspondence degree programs so that graduates would be encouraged to pursue advanced degree programs offered elsewhere by educational institutions. The study focused…

  1. Simplified Asset Indices to Measure Wealth and Equity in Health Programs: A Reliability and Validity Analysis Using Survey Data From 16 Countries.

    Science.gov (United States)

    Chakraborty, Nirali M; Fry, Kenzo; Behl, Rasika; Longfield, Kim

    2016-03-01

    Social franchising programs in low- and middle-income countries have tried using the standard wealth index, based on the Demographic and Health Survey (DHS) questionnaire, in client exit interviews to assess clients' relative wealth compared with the national wealth distribution to ensure equity in service delivery. The large number of survey questions required to capture the wealth index variables have proved cumbersome for programs. Using an adaptation of the Delphi method, we developed shortened wealth indices and in February 2015 consulted 15 stakeholders in equity measurement. Together, we selected the best of 5 alternative indices, accompanied by 2 measures of agreement (percent agreement and Cohen's kappa statistic) comparing wealth quintile assignment in the new indices to the full DHS index. The panel agreed that reducing the number of assets was more important than standardization across countries because a short index would provide strong indication of client wealth and be easier to collect and use in the field. Additionally, the panel agreed that the simplified index should be highly correlated with the DHS for each country (kappa ≥ 0.75) for both national and urban-specific samples. We then revised indices for 16 countries and selected the minimum number of questions and question options required to achieve a kappa statistic ≥ 0.75 for both national and urban populations. After combining the 5 wealth quintiles into 3 groups, which the expert panel deemed more programmatically meaningful, reliability between the standard DHS wealth index and each of 3 simplified indices was high (median kappa = 0.81, 086, and 0.77, respectively, for index B that included only the common questions from the DHS VI questionnaire, index D that included the common questions plus country-specific questions, and index E that found the shortest list of common and country-specific questions that met the minimum reliability criteria of kappa ≥ 0.75). Index E was the

  2. Simplified Asset Indices to Measure Wealth and Equity in Health Programs: A Reliability and Validity Analysis Using Survey Data From 16 Countries

    Science.gov (United States)

    Chakraborty, Nirali M; Fry, Kenzo; Behl, Rasika; Longfield, Kim

    2016-01-01

    ABSTRACT Background: Social franchising programs in low- and middle-income countries have tried using the standard wealth index, based on the Demographic and Health Survey (DHS) questionnaire, in client exit interviews to assess clients’ relative wealth compared with the national wealth distribution to ensure equity in service delivery. The large number of survey questions required to capture the wealth index variables have proved cumbersome for programs. Methods: Using an adaptation of the Delphi method, we developed shortened wealth indices and in February 2015 consulted 15 stakeholders in equity measurement. Together, we selected the best of 5 alternative indices, accompanied by 2 measures of agreement (percent agreement and Cohen’s kappa statistic) comparing wealth quintile assignment in the new indices to the full DHS index. The panel agreed that reducing the number of assets was more important than standardization across countries because a short index would provide strong indication of client wealth and be easier to collect and use in the field. Additionally, the panel agreed that the simplified index should be highly correlated with the DHS for each country (kappa ≥ 0.75) for both national and urban-specific samples. We then revised indices for 16 countries and selected the minimum number of questions and question options required to achieve a kappa statistic ≥ 0.75 for both national and urban populations. Findings: After combining the 5 wealth quintiles into 3 groups, which the expert panel deemed more programmatically meaningful, reliability between the standard DHS wealth index and each of 3 simplified indices was high (median kappa = 0.81, 086, and 0.77, respectively, for index B that included only the common questions from the DHS VI questionnaire, index D that included the common questions plus country-specific questions, and index E that found the shortest list of common and country-specific questions that met the minimum reliability

  3. Programming standards for effective S-3D game development

    Science.gov (United States)

    Schneider, Neil; Matveev, Alexander

    2008-02-01

    When a video game is in development, more often than not it is being rendered in three dimensions - complete with volumetric depth. It's the PC monitor that is taking this three-dimensional information, and artificially displaying it in a flat, two-dimensional format. Stereoscopic drivers take the three-dimensional information captured from DirectX and OpenGL calls and properly display it with a unique left and right sided view for each eye so a proper stereoscopic 3D image can be seen by the gamer. The two-dimensional limitation of how information is displayed on screen has encouraged programming short-cuts and work-arounds that stifle this stereoscopic 3D effect, and the purpose of this guide is to outline techniques to get the best of both worlds. While the programming requirements do not significantly add to the game development time, following these guidelines will greatly enhance your customer's stereoscopic 3D experience, increase your likelihood of earning Meant to be Seen certification, and give you instant cost-free access to the industry's most valued consumer base. While this outline is mostly based on NVIDIA's programming guide and iZ3D resources, it is designed to work with all stereoscopic 3D hardware solutions and is not proprietary in any way.

  4. Inter-examiner reliability of a standardized Ultra-sonographic method for classification of changes related to supraspinatus tendinopathy – a pilot study

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Ingwersen, Kim Gordon; Hjarnbæk, John

    2015-01-01

    Inter-examiner reliability of a standardized Ultra-sonographic method for classification of changes related to supraspinatus tendinopathy – a pilot study Ingwersen KG1, 2, Hjarbaek J3, Eshøj H1, Larsen CM1, 4, Vobbe J5, Juul-Kristensen B1, 6 1Institute of Sports Science and Clinical Biomechanics......, University of Southern Denmark, Odense, Denmark. 2Physiotherapy Department, Hospital Lillebaelt, Vejle Hospital, Vejle, Denmark 3Department of Radiology, Musculoskeletal section, Odense University Hospital, Odense, Denmark 4Health Sciences Research Centre, University College Lillebaelt, Odense Denmark 5...... athletes. For optimizing rehabilitation to the different stages of tendinopathy (1) ultra-sonography (US) may be used. Reliability of such method for RT is lacking. Aims. To develop and test inter-examiner reliability of US for classifying RT. Materials and Methods. A three-phased standardized protocol...

  5. Visualization of postoperative anterior cruciate ligament reconstruction bone tunnels: Reliability of standard radiographs, CT scans, and 3D virtual reality images

    NARCIS (Netherlands)

    D.E. Meuffels (Duncan); J.W. Potters (Jan Willem); A.H.J. Koning (Anton); C.H. Brown Jr Jr. (Charles); J.A.N. Verhaar (Jan); M. Reijman (Max)

    2011-01-01

    textabstractBackground and purpose: Non-anatomic bone tunnel placement is the most common cause of a failed ACL reconstruction. Accurate and reproducible methods to visualize and document bone tunnel placement are therefore important. We evaluated the reliability of standard radiographs, CT scans,

  6. Military Personnel: DMDC Data on Officers' Commissioning Programs is Insufficiently Reliable and Needs to be Corrected

    National Research Council Canada - National Science Library

    Stewart, Derek B

    2007-01-01

    .... The purpose of this report is to bring to your attention reliability issues with DMDC data that we encountered while preparing our report and to provide you with our recommendations to address these issues...

  7. Secondary calibration laboratory for ionizing radiation laboratory accreitation program National Institute of Standards and Technology National Voluntary Laboratory Accreditation Program

    Energy Technology Data Exchange (ETDEWEB)

    Martin, P.R.

    1993-12-31

    This paper presents an overview of the procedures and requirements for accreditation under the Secondary Calibration Laboratory for Ionizing Radiation Program (SCLIR LAP). The requirements for a quality system, proficiency testing and the onsite assessment are discussed. The purpose of the accreditation program is to establish a network of secondary calibration laboratories that can provide calibrations traceable to the primary national standards.

  8. Secondary calibration laboratory for ionizing radiation laboratory accreitation program National Institute of Standards and Technology National Voluntary Laboratory Accreditation Program

    International Nuclear Information System (INIS)

    Martin, P.R.

    1993-01-01

    This paper presents an overview of the procedures and requirements for accreditation under the Secondary Calibration Laboratory for Ionizing Radiation Program (SCLIR LAP). The requirements for a quality system, proficiency testing and the onsite assessment are discussed. The purpose of the accreditation program is to establish a network of secondary calibration laboratories that can provide calibrations traceable to the primary national standards

  9. EPA's LLW standards program: Below regulatory concern criteria development

    International Nuclear Information System (INIS)

    Holcomb, W.F.; Gruhlke, J.M.

    1987-01-01

    The Environmental Protection Agency (EPA) is developing generally applicable environmental standards for land disposal of low-level radioactive wastes. These standards will include criteria for determining which wastes have sufficiently low levels of radioactivity to be considered ''Below Regulatory Concern'' (BRC) in regards to their radiation hazard. Risk assessments to support the BRC criteria include an analysis of 18 surrogate radioactive waste streams, generated by nuclear power reactors and other fuel cycle facilities, industrial, medical and educational facilities, and consumers. Deregulated disposal alternatives, such as sanitary landfills, municipal dumps, incinerators and on-site landfills, situated in diverse demographic settings are used in the analysis. A number of waste streams which contributed only small doses or fractions of a health effect over 10,000 years were identified. Disposal of such wastes without consideration of their very low radioactivity could result in significant cost savings to the commercial fuel cycle and government operations as well as to medical, educational, and industrial facilities, and with minimal risk to the public. The concept of BRC wastes appears both feasible and cost effective

  10. DOE standard: The Department of Energy Laboratory Accreditation Program for radiobioassay

    International Nuclear Information System (INIS)

    1998-12-01

    This technical standard describes the US Department of Energy Laboratory Accreditation Program (DOELAP) for Radiobioassay, for use by the US Department of Energy (DOE) and DOE Contractor radiobioassay programs. This standard is intended to be used in conjunction with the general administrative technical standard that describes the overall DOELAP accreditation process--DOE-STD-1111-98, Department of Energy Laboratory Accreditation Program Administration. This technical standard pertains to radiobioassay service laboratories that provide either direct or indirect (in vivo or in vitro) radiobioassay measurements in support of internal dosimetry programs at DOE facilities or for DOE and DOE contractors. Similar technical standards have been developed for other DOELAP dosimetry programs. This program consists of providing an accreditation to DOE radiobioassay programs based on successful completion of a performance-testing process and an on-site evaluation by technical experts. This standard describes the technical requirements and processes specific to the DOELAP Radiobioassay Accreditation Program as required by 10 CFR 835 and as specified generically in DOE-STD-1111-98

  11. ABACC laboratories quality assurance through Secondary Standards Exchange Program

    International Nuclear Information System (INIS)

    Guidicini, Olga Mafra; Thompson, Jay; Soriano, Michael

    2003-01-01

    In September 1999, the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC), with assistance from the New Brunswick Laboratory (NBL) of the U.S. Department of Energy, started a new cooperative activity with, among other objectives, the production and characterization of a traceable uranium secondary standard and the performance of the Third Round Robin for ABACC's laboratory network. Brazil and Argentina have fabricated UO 2 pellets for use as a secondary standard. Samples from the two batches were sent to NBL for the determination of the reference values for both uranium concentration (%U) and isotopic composition for each batch. ABACC and NBL then organized the Third ABACC Round Robin for Brazilian and Argentine laboratories that are part of the ABACC network. The laboratories comprising the network can be used to analyze real samples collected during the ABACC inspections. The Brazilian and Argentine pellets were distributed to all the laboratories together with the protocol to be followed for the uranium concentration analysis, the forms for reporting the measurement results, and natural UO 2 pellets (CETAMA OU1) to be used as reference material. For the laboratories with capability of measuring isotopics, NBL reference material CRM 125-A was provided. Several laboratories from each country provided results. As soon as the measurement results were sent to the organizers, they were statistically evaluated by NBL. During a meeting held at ABACC headquarters with the participation of NBL representatives, the ABACC technical support officer, and representatives of all the participant laboratories, the results were discussed and compared with the reference values. All the laboratories had the occasion, in an open discussion, to explain and show the difficulties and problems they faced during the exercise. ABACC had the opportunity not only to judge the quality of the measurements these laboratories performed, but also to determine

  12. Integrated Data Analysis (IDCA) Program - PETN Class 4 Standard

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Shelley, Timothy J. [Air Force Research Lab. (AFRL), Tyndall AFB, FL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Phillips, Jason J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2012-08-01

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of PETN Class 4. The PETN was found to have: 1) an impact sensitivity (DH50) range of 6 to 12 cm, 2) a BAM friction sensitivity (F50) range 7 to 11 kg, TIL (0/10) of 3.7 to 7.2 kg, 3) a ABL friction sensitivity threshold of 5 or less psig at 8 fps, 4) an ABL ESD sensitivity threshold of 0.031 to 0.326 j/g, and 5) a thermal sensitivity of an endothermic feature with Tmin = ~ 141 °C, and a exothermic feature with a Tmax = ~205°C.

  13. Scinfi, a program to calculate the standardization curve in liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1984-01-01

    A code, Scinfi, was developed, written in Basic, to compute the efficiency-quench standardization curve for any radionuclide. The program requires the standardization curve for 3 H and the polynomial relations between counting efficiency and figure of merit for both 3 H and the problem (e.g. 14 C). The program is applied to the computation of the efficiency-quench standardization curve for 14 C. Five different liquid scintillation spectrometers and two scintillator solutions have been checked. The computation results are compared with the experimental values obtained with a set of 14 C standardized samples. (author)

  14. SCINFI, a program to calculate the standardization curve in liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1984-01-01

    A code, SCINFI, was developed, written in BASIC, to compute the efficiency- quench standardization curve for any radionuclide. The program requires the standardization curve for 3H and the polynomial relations between counting efficiency and figure of merit for both 3H and the problem (e.g. 14 C ). The program is applied to the computation of the efficiency-quench standardization curve for 14 c . Five different liquid scintillation spectrometers and two scintillator solutions have bean checked. The computation results are compared with the experimental values obtained with a set of 14 c standardized samples. (Author)

  15. Intra-rater and inter-rater reliability of the standardized ultrasound protocol for assessing subacromial structures

    DEFF Research Database (Denmark)

    Hougs Kjær, Birgitte; Ellegaard, Karen; Wieland, Ina

    2017-01-01

    BACKGROUND: US-examinations related to shoulder impingement (SI) often vary due to methodological differences, examiner positions, transducers, and recording parameters. Reliable US protocols for examination of different structures related to shoulder impingement are therefore needed. OBJECTIVES...... of the supraspinatus tendon (SUPRA) and subacromial subdeltoid (SASD) bursa in two imaging positions, and the acromial humeral distance (AHD) in one position. Additionally, agreement on dynamic impingement (DI) examination was performed. The intra- and inter-rater reliability was carried out on the same day...

  16. Korean round-robin result for new international program to assess the reliability of emerging nondestructive techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Cho; Kim, Jin Gyum; Kang, Sung Sik; Jhung, Myung Jo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2017-04-15

    The Korea Institute of Nuclear Safety, as a representative organization of Korea, in February 2012 participated in an international Program to Assess the Reliability of Emerging Nondestructive Techniques initiated by the U.S. Nuclear Regulatory Commission. The goal of the Program to Assess the Reliability of Emerging Nondestructive Techniques is to investigate the performance of emerging and prospective novel nondestructive techniques to find flaws in nickel-alloy welds and base materials. In this article, Korean round-robin test results were evaluated with respect to the test blocks and various nondestructive examination techniques. The test blocks were prepared to simulate large-bore dissimilar metal welds, small-bore dissimilar metal welds, and bottom-mounted instrumentation penetration welds in nuclear power plants. Also, lessons learned from the Korean round-robin test were summarized and discussed.

  17. Radioactivity standards distribution program, 1978--1979. Interim report, 1978--1979

    International Nuclear Information System (INIS)

    Ziegler, L.H.

    1978-06-01

    A program for the distribution of calibrated radioactive samples, as one function of EPA's quality assurance program for environmental radiation measurements, is described. Included is a discussion of the objectives of the distribution program and a description of the preparation, availability, and distribution of calibrated radioactive samples. Instructions and application forms are included for laboratories desiring to participate in the program. This document is not a research report. It is designed for use by personnel of laboratories participating or desiring to participate in the Radioactivity Standards Distribution Program, which is a part of the U.S. Environmental Protection Agency's quality assurance program

  18. An evaluation of the Browns Ferry Nuclear Plant preventive maintenance program based on reliability centered maintenance analysis

    International Nuclear Information System (INIS)

    McCullough, C.L.; McCullough, C.A.

    1989-01-01

    Reliability centered maintenance (RCM) techniques were used to support a preventative maintenance (PM) upgrade program (PMUP) performed at TVA Browns Ferry Nuclear Plant (BFNP). The purpose of the RCM analysis was to identify critical equipment based on risk and economic importance and to evaluate the PM activities applicable to that equipment. The analysis may be conveniently divided into three steps, which will be outlined in the Approach section of this paper. The net benefit of the RCM approach was a prioritization of the focus of the PM upgrade program so that plant components receive attention proportional to their importance, and assurance that PM activities properly address the most likely component failure causes

  19. Physical Fitness Reference Standards in French Youth: The BOUGE Program.

    Science.gov (United States)

    Vanhelst, Jérémy; Labreuche, Julien; Béghin, Laurent; Drumez, Elodie; Fardy, Paul S; Chapelot, Didier; Mikulovic, Jacques; Ulmer, Zékya

    2017-06-01

    The aim of this study was to establish sex- and age-specific physical fitness percentiles in French youth. A sample of 11,186 children and adolescents (5,546 boys and 5,640 girls), aged between 10 and 15 years, was assessed in the French national BOUGE study. Participants were tested for their cardiorespiratory fitness, muscular endurance, speed, flexibility, and agility using the following tests: 20-m shuttle run tests, curl-ups test, 50-m sprint test, back-saver sit and reach test, and 10 × 5-m shuttle run test. Percentile values were estimated for French youth as a function of age stratified by sex using the generalized additive model for location, scale, and shape (GAMLSS). In general, physical fitness was better in boys than in girls, except for the back-saver sit and reach test, in which girls performed better. Except for the back-saver sit and reach test and 10 × 5-m shuttle run test, physical fitness performance was significantly associated with age. Sex- and age-specific normative values for physical fitness tests in French youth expressed as percentiles from the fifth to the 95th are provided. Reference values provide normative data for French youth. The data are useful in identifying special needs for appropriate intervention programs.

  20. Systems analysis programs for hands-on integrated reliability evaluations (SAPHIRE) version 5.0, technical reference manual

    International Nuclear Information System (INIS)

    Russell, K.D.; Atwood, C.L.; Galyean, W.J.; Sattison, M.B.; Rasmuson, D.M.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. This volume provides information on the principles used in the construction and operation of Version 5.0 of the Integrated Reliability and Risk Analysis System (IRRAS) and the System Analysis and Risk Assessment (SARA) system. It summarizes the fundamental mathematical concepts of sets and logic, fault trees, and probability. This volume then describes the algorithms that these programs use to construct a fault tree and to obtain the minimal cut sets. It gives the formulas used to obtain the probability of the top event from the minimal cut sets, and the formulas for probabilities that are appropriate under various assumptions concerning repairability and mission time. It defines the measures of basic event importance that these programs can calculate. This volume gives an overview of uncertainty analysis using simple Monte Carlo sampling or Latin Hypercube sampling, and states the algorithms used by these programs to generate random basic event probabilities from various distributions. Further references are given, and a detailed example of the reduction and quantification of a simple fault tree is provided in an appendix

  1. 34 CFR 369.44 - What wage and hour standards apply to community rehabilitation programs?

    Science.gov (United States)

    2010-07-01

    ... VOCATIONAL REHABILITATION SERVICE PROJECTS What Conditions Must Be Met by a Grantee? § 369.44 What wage and... hour standards must be observed in projects carried out in community rehabilitation programs...

  2. The Brazilian time and frequency atomic standards program

    Directory of Open Access Journals (Sweden)

    Mushtaq Ahmed

    2008-06-01

    Full Text Available Cesium atomic beam clocks have been the workhorse for many demanding applications in science and technology for the past four decades. Tests of the fundamental laws of physics and the search for minute changes in fundamental constants, the synchronization of telecommunication networks, and realization of the satellite-based global positioning system would not be possible without atomic clocks. The adoption of optical cooling and trapping techniques, has produced a major advance in atomic clock precision. Cold-atom fountain and compact cold-atom clocks have also been developed. Measurement precision of a few parts in 10(15 has been demonstrated for a cold-atom fountain clock. We present here an overview of the time and frequency metrology program based on cesium atoms under development at USP São Carlos. This activity consists of construction and characterization of atomic-beam, and several variations of cold-atom clocks. We discuss the basic working principles, construction, evaluation, and important applications of atomic clocks in the Brazilian program.Relógios atômicos de feixe de Césio têm sido a base para diversas aplicações em ciência e tecnologia nas últimas quatro décadas. Testes de leis fundamentais de física, buscas por mínimas variações em constantes fundamentais, sincronização de redes de telecomunicações e o funcionamento do sistema de posicionamento global, baseado em satélites de navegação, não seriam possíveis sem os relógios atômicos. A adoção de técnicas de aprisionamento e resfriamento ópticos tem permitido um grande avanço na precisão dos relógios atômicos. Chafarizes de átomos frios e relógios compactos de átomos frios também têm sido desenvolvidos. Precisões de medida de algumas partes em 1015 foram demonstradas para relógios do tipo chafariz de átomos frios. Apresentamos uma visão geral do programa de metrologia de tempo e freqüência baseado em átomos de césio, em

  3. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE)

    International Nuclear Information System (INIS)

    C. L. Smith

    2006-01-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer (PC) running the Microsoft Windows operating system. SAPHIRE is primarily funded by the U.S. Nuclear Regulatory Commission (NRC) and developed by the Idaho National Laboratory (INL). INL's primary role in this project is that of software developer and tester. However, INL also plays an important role in technology transfer by interfacing and supporting SAPHIRE users, who constitute a wide range of PRA practitioners from the NRC, national laboratories, the private sector, and foreign countries. SAPHIRE can be used to model a complex system's response to initiating events and quantify associated consequential outcome frequencies. Specifically, for nuclear power plant applications, SAPHIRE can identify important contributors to core damage (Level 1 PRA) and containment failure during a severe accident which lead to releases (Level 2 PRA). It can be used for a PRA where the reactor is at full power, low power, or at shutdown conditions. Furthermore, it can be used to analyze both internal and external initiating events and has special features for transforming an internal events model to a model for external events, such as flooding and fire analysis. It can also be used in a limited manner to quantify risk in terms of release consequences to the public and environment (Level 3 PRA). SAPHIRE also includes a separate module called the Graphical Evaluation Module (GEM). GEM is a special user interface linked to SAPHIRE that automates the SAPHIRE process steps for evaluating operational events at commercial nuclear power plants. Using GEM, an analyst can estimate the risk associated with operational events (for example, to calculate a conditional core damage probability) very efficiently and expeditiously. This report provides an overview of the functions

  4. The National Surgical Quality Improvement Program 30-Day Challenge: Microsurgical Breast Reconstruction Outcomes Reporting Reliability

    Directory of Open Access Journals (Sweden)

    Austin D. Chen

    2018-03-01

    Conclusion:. For immediate, free-tissue breast reconstruction, the ACS-NSQIP may be reliable for monitoring and comparing SSI, WD, URO, and URA rates. However, clinicians may find it useful to understand limitations of the ACS-NSQIP for complications and risk factors, as it may underreport complications occurring beyond 30 days.

  5. R&D program benefits estimation: DOE Office of Electricity Delivery and Energy Reliability

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2006-12-04

    The overall mission of the U.S. Department of Energy’s Office of Electricity Delivery and Energy Reliability (OE) is to lead national efforts to modernize the electric grid, enhance the security and reliability of the energy infrastructure, and facilitate recovery from disruptions to the energy supply. In support of this mission, OE conducts a portfolio of research and development (R&D) activities to advance technologies to enhance electric power delivery. Multiple benefits are anticipated to result from the deployment of these technologies, including higher quality and more reliable power, energy savings, and lower cost electricity. In addition, OE engages State and local government decision-makers and the private sector to address issues related to the reliability and security of the grid, including responding to national emergencies that affect energy delivery. The OE R&D activities are comprised of four R&D lines: High Temperature Superconductivity (HTS), Visualization and Controls (V&C), Energy Storage and Power Electronics (ES&PE), and Distributed Systems Integration (DSI).

  6. Reliability and validity of a novel Kinect-based software program for measuring posture, balance and side-bending.

    Science.gov (United States)

    Grooten, Wilhelmus Johannes Andreas; Sandberg, Lisa; Ressman, John; Diamantoglou, Nicolas; Johansson, Elin; Rasmussen-Barr, Eva

    2018-01-08

    Clinical examinations are subjective and often show a low validity and reliability. Objective and highly reliable quantitative assessments are available in laboratory settings using 3D motion analysis, but these systems are too expensive to use for simple clinical examinations. Qinematic™ is an interactive movement analyses system based on the Kinect camera and is an easy-to-use clinical measurement system for assessing posture, balance and side-bending. The aim of the study was to test the test-retest the reliability and construct validity of Qinematic™ in a healthy population, and to calculate the minimal clinical differences for the variables of interest. A further aim was to identify the discriminative validity of Qinematic™ in people with low-back pain (LBP). We performed a test-retest reliability study (n = 37) with around 1 week between the occasions, a construct validity study (n = 30) in which Qinematic™ was tested against a 3D motion capture system, and a discriminative validity study, in which a group of people with LBP (n = 20) was compared to healthy controls (n = 17). We tested a large range of psychometric properties of 18 variables in three sections: posture (head and pelvic position, weight distribution), balance (sway area and velocity in single- and double-leg stance), and side-bending. The majority of the variables in the posture and balance sections, showed poor/fair reliability (ICC validity (Spearman reliability (ICC =0.898), excellent validity (r = 0.943), and Qinematic™ could differentiate between LPB and healthy individuals (p = 0.012). This paper shows that a novel software program (Qinematic™) based on the Kinect camera for measuring balance, posture and side-bending has poor psychometric properties, indicating that the variables on balance and posture should not be used for monitoring individual changes over time or in research. Future research on the dynamic tasks of Qinematic™ is warranted.

  7. 78 FR 51463 - Energy Conservation Program: Energy Conservation Standards for Metal Halide Lamp Fixtures

    Science.gov (United States)

    2013-08-20

    ... merging the metal halide lamp fixture and the high-intensity discharge (HID) lamp rulemakings. This NOPR... Conservation Program: Energy Conservation Standards for Metal Halide Lamp Fixtures; Proposed Rule #0;#0;Federal...: Energy Conservation Standards for Metal Halide Lamp Fixtures AGENCY: Office of Energy Efficiency and...

  8. Do School-Based Tutoring Programs Significantly Improve Student Performance on Standardized Tests?

    Science.gov (United States)

    Rothman, Terri; Henderson, Mary

    2011-01-01

    This study used a pre-post, nonequivalent control group design to examine the impact of an in-district, after-school tutoring program on eighth grade students' standardized test scores in language arts and mathematics. Students who had scored in the near-passing range on either the language arts or mathematics aspect of a standardized test at the…

  9. 75 FR 20111 - Energy Conservation Program: Energy Conservation Standards for Residential Water Heaters, Direct...

    Science.gov (United States)

    2010-04-16

    ... Program: Energy Conservation Standards for Residential Water Heaters, Direct Heating Equipment, and Pool... heating equipment and pool heaters. Table I.1--Amended Energy Conservation Standards for Residential Water... for national energy and water conservation; and 7. Other factors the Secretary of Energy (Secretary...

  10. 77 FR 10997 - Energy Conservation Program: Energy Conservation Standards for Distribution Transformers; Correction

    Science.gov (United States)

    2012-02-24

    ... Conservation Program: Energy Conservation Standards for Distribution Transformers; Correction AGENCY: Office of... standards for distribution transformers. It was recently discovered that values in certain tables of the...,'' including distribution transformers. The Energy Policy Act of 1992 (EPACT 1992), Public Law 102-486, amended...

  11. 78 FR 63999 - Notice of Vitamin D Standardization Program (VDSP) Symposium: Tools To Improve Laboratory...

    Science.gov (United States)

    2013-10-25

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health Notice of Vitamin D... Vitamin D Standardization Program (VDSP) to those with an interest in the effort to standardize vitamin D... laboratory personnel; vitamin D researchers; and members of professional societies with clinical and public...

  12. Analysis of Evidence Supporting the Educational Leadership Constituent Council 2011 Educational Leadership Program Standards

    Science.gov (United States)

    Tucker, Pamela D.; Anderson, Erin; Reynolds, Amy L.; Mawhinney, Hanne

    2016-01-01

    This document analysis provides a summary of the research from high-impact journals published between 2008 and 2013 with the explicit purpose of determining the extent to which the current empirical evidence supports the individual 2011 Educational Leadership Constituent Council Program Standards and their elements. We found that the standards are…

  13. Reliability Engineering

    CERN Document Server

    Lazzaroni, Massimo

    2012-01-01

    This book gives a practical guide for designers and users in Information and Communication Technology context. In particular, in the first Section, the definition of the fundamental terms according to the international standards are given. Then, some theoretical concepts and reliability models are presented in Chapters 2 and 3: the aim is to evaluate performance for components and systems and reliability growth. Chapter 4, by introducing the laboratory tests, puts in evidence the reliability concept from the experimental point of view. In ICT context, the failure rate for a given system can be

  14. Study on Design and Implementation of JAVA Programming Procedural Assessment Standard

    Science.gov (United States)

    Tingting, Xu; Hua, Ma; Xiujuan, Wang; Jing, Wang

    2015-01-01

    The traditional JAVA course examination is just a list of questions from which we cannot know students' skills of programming. According to the eight abilities in curriculum objectives, we designed an assessment standard of JAVA programming course that is based on employment orientation and apply it to practical teaching to check the teaching…

  15. 77 FR 38743 - Energy Efficiency Program for Consumer Products: Energy Conservation Standards for Battery...

    Science.gov (United States)

    2012-06-29

    ... Efficiency Program for Consumer Products: Energy Conservation Standards for Battery Chargers and External Power Supplies AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION... Energy Efficiency and Renewable Energy, Building Technologies Program, EE-2J, 1000 Independence Avenue SW...

  16. 78 FR 9631 - Energy Efficiency Program for Consumer Products: Energy Conservation Standards for Residential...

    Science.gov (United States)

    2013-02-11

    ... Efficiency Program for Consumer Products: Energy Conservation Standards for Residential Boilers AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Notice of public meeting.... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, EE-2J...

  17. Reliability and standard market design : a square plug and a round socket, the fundamental flaw of the market design

    International Nuclear Information System (INIS)

    Bekman, K.

    2003-01-01

    A electricity power system is designed and built to deliver reliable power supplies. A failure of a single component should not lead to the failure of the entire system. Oversupply results in prices at marginal cost of production, inadequate return on capital investment and economic failure of supplies. Uneconomic sources of supply would pull out in cases of oversupply. Competitive markets need flexible supply and demand and scarcity pricing in order to promote new investment. The problem with such a scenario is that scarcity reduces the level of reliability. An oversupply, while ensuring reliability, offers an inadequate return on capital. This presentation included several graphs depicting results of market failure with reference to NYMEX analysis of credit quality, NEPOOL summer capacity 2001, NYS summer capacity 2001, and PJM summer capacity 2001. A graph illustrating a New England 2002 load duration curve and its analysis was also included. According to the author, the market design is flawed because it does not pay for reliability. It fails to compensate generation for capital at risk, and it fails to address the fact that nearly half of the capacity supplies less than 10 per cent energy. He notes that the liquidity crisis will continue and grow unless changes are made and new entrants come into the market. 8 figs

  18. Validity and reliability of portfolio assessment of competency in a baccalaureate dental hygiene program

    Science.gov (United States)

    Gadbury-Amyot, Cynthia C.

    This study examined validity and reliability of portfolio assessment using Messick's (1996, 1995) unified framework of construct validity. Theoretical and empirical evidence was sought for six aspects of construct validity. The sample included twenty student portfolios. Each portfolio were evaluated by seven faculty raters using a primary trait analysis scoring rubric. There was a significant relationship (r = .81--.95; p Dental Hygiene Board Examination (r = .60; p Dental Testing Service examination was both weak and nonsignificant (r = .19; p > .05). An open-ended survey was used to elicit student feedback on portfolio development. A majority of the students (76%) perceived value in the development of programmatic portfolios. In conclusion, the pattern of findings from this study suggest that portfolios can serve as a valid and reliable measure for assessing student competency.

  19. Reliability, standard error, and minimum detectable change of clinical pressure pain threshold testing in people with and without acute neck pain.

    Science.gov (United States)

    Walton, David M; Macdermid, Joy C; Nielson, Warren; Teasell, Robert W; Chiasson, Marco; Brown, Lauren

    2011-09-01

    Clinical measurement. To evaluate the intrarater, interrater, and test-retest reliability of an accessible digital algometer, and to determine the minimum detectable change in normal healthy individuals and a clinical population with neck pain. Pressure pain threshold testing may be a valuable assessment and prognostic indicator for people with neck pain. To date, most of this research has been completed using algometers that are too resource intensive for routine clinical use. Novice raters (physiotherapy students or clinical physiotherapists) were trained to perform algometry testing over 2 clinically relevant sites: the angle of the upper trapezius and the belly of the tibialis anterior. A convenience sample of normal healthy individuals and a clinical sample of people with neck pain were tested by 2 different raters (all participants) and on 2 different days (healthy participants only). Intraclass correlation coefficient (ICC), standard error of measurement, and minimum detectable change were calculated. A total of 60 healthy volunteers and 40 people with neck pain were recruited. Intrarater reliability was almost perfect (ICC = 0.94-0.97), interrater reliability was substantial to near perfect (ICC = 0.79-0.90), and test-retest reliability was substantial (ICC = 0.76-0.79). Smaller change was detectable in the trapezius compared to the tibialis anterior. This study provides evidence that novice raters can perform digital algometry with adequate reliability for research and clinical use in people with and without neck pain.

  20. Reliability and Validity of the Sensory Component of the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI): A Systematic Review.

    Science.gov (United States)

    Hales, M; Biros, E; Reznik, J E

    2015-01-01

    Since 1982, the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI) has been used to classify sensation of spinal cord injury (SCI) through pinprick and light touch scores. The absence of proprioception, pain, and temperature within this scale creates questions about its validity and accuracy. To assess whether the sensory component of the ISNCSCI represents a reliable and valid measure of classification of SCI. A systematic review of studies examining the reliability and validity of the sensory component of the ISNCSCI published between 1982 and February 2013 was conducted. The electronic databases MEDLINE via Ovid, CINAHL, PEDro, and Scopus were searched for relevant articles. A secondary search of reference lists was also completed. Chosen articles were assessed according to the Oxford Centre for Evidence-Based Medicine hierarchy of evidence and critically appraised using the McMasters Critical Review Form. A statistical analysis was conducted to investigate the variability of the results given by reliability studies. Twelve studies were identified: 9 reviewed reliability and 3 reviewed validity. All studies demonstrated low levels of evidence and moderate critical appraisal scores. The majority of the articles (~67%; 6/9) assessing the reliability suggested that training was positively associated with better posttest results. The results of the 3 studies that assessed the validity of the ISNCSCI scale were confounding. Due to the low to moderate quality of the current literature, the sensory component of the ISNCSCI requires further revision and investigation if it is to be a useful tool in clinical trials.

  1. Reliability calculations

    International Nuclear Information System (INIS)

    Petersen, K.E.

    1986-03-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very complex systems. In order to increase the applicability of the programs variance reduction techniques can be applied to speed up the calculation process. Variance reduction techniques have been studied and procedures for implementation of importance sampling are suggested. (author)

  2. Measuring Program Quality, Part 2: Addressing Potential Cultural Bias in a Rater Reliability Exam

    Science.gov (United States)

    Richer, Amanda; Charmaraman, Linda; Ceder, Ineke

    2018-01-01

    Like instruments used in afterschool programs to assess children's social and emotional growth or to evaluate staff members' performance, instruments used to evaluate program quality should be free from bias. Practitioners and researchers alike want to know that assessment instruments, whatever their type or intent, treat all people fairly and do…

  3. Safety implications of standardized continuous quality improvement programs in community pharmacy.

    Science.gov (United States)

    Boyle, Todd A; Ho, Certina; Mackinnon, Neil J; Mahaffey, Thomas; Taylor, Jeffrey M

    2013-06-01

    Standardized continuous quality improvement (CQI) programs combine Web-based technologies and standardized improvement processes, tools, and expectations to enable quality-related events (QREs) occurring in individual pharmacies to be shared with pharmacies in other jurisdictions. Because standardized CQI programs are still new to community pharmacy, little is known about how they impact medication safety. This research identifies key aspects of medication safety that change as a result of implementing a standardized CQI program. Fifty-three community pharmacies in Nova Scotia, Canada, adopted the SafetyNET-Rx standardized CQI program in April 2010. The Institute for Safe Medication Practices (ISMP) Canada's Medication Safety Self-Assessment (MSSA) survey was administered to these pharmacies before and 1 year into their use of the SafetyNET-Rx program. The nonparametric Wilcoxon signed-rank test was used to explore where changes in patient safety occurred as a result of SafetyNETRx use. Significant improvements occurred with quality processes and risk management, staff competence, and education, and communication of drug orders and other information. Patient education, environmental factors, and the use of devices did not show statistically significant changes. As CQI programs are designed to share learning from QREs, it is reassuring to see that the largest improvements are related to quality processes, risk management, staff competence, and education.

  4. Evaluation model applied to TRANSPETRO's Marine Terminals Standardization Program

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de; Mueller, Gabriela [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Garcia, Luciano Maldonado [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes an innovative evaluation model applied to TRANSPETRO's 'Marine Terminals Standardization Program' based on updating approaches of programs evaluation and organizational learning. Since the program was launched in 2004, the need for having an evaluation model able to evaluate its implementation progress, to measure the degree of standards compliance and its potential economic, social and environmental impacts has become evident. Within a vision of safe and environmentally responsible operations of marine terminals, this evaluation model was jointly designed by TRANSPETRO and PUC-Rio to promote continuous improvement and learning in operational practices and in the standardization process itself. TRANSPETRO believes that standardization supports its services and management innovation capability by creating objective and internationally recognized parameters, targets and metrology for its business activities. The conceptual model and application guidelines for this important tool are presented in this paper, as well as the next steps towards its implementation. (author)

  5. Probabilistic safety assessment of Tehran Research Reactor using systems analysis programs for hands-on integrated reliability evaluations

    International Nuclear Information System (INIS)

    Hosseini, M.H.; Nematollahi, M.R.; Sepanloo, K.

    2004-01-01

    Probabilistic safety assessment application is found to be a practical tool for research reactor safety due to intense involvement of human interactions in an experimental facility. In this document the application of the probabilistic safety assessment to the Tehran Research Reactor is presented. The level 1 practicabilities safety assessment application involved: Familiarization with the plant, selection of accident initiators, mitigating functions and system definitions, event tree constructions and quantifications, fault tree constructions and quantification, human reliability, component failure data base development and dependent failure analysis. Each of the steps of the analysis given above is discussed with highlights from the selected results. Quantification of the constructed models is done using systems analysis programs for hands-on integrated reliability evaluations software

  6. Review of standards and guidelines pertinent to DOE's remedial action programs

    International Nuclear Information System (INIS)

    Soldat, J.K.; Denham, D.H.

    1984-10-01

    A number of radiological standards, guidelines, and dose criteria have been promulgated that may be relevant to the Department of Energy's (DOE) Remedial Action programs. Some of these will be applied to remedial actions undertaken by DOE to ensure that health and safety aspects will be adequately addressed. Pacific Northwest Laboratory staff are reviewing and evaluating existing and proposed environmental radiological standards and criteria for their applicability. National and international environmental standards and criteria, and studies conducted by other DOE contractors are being evaluated. The aim of the review is to identify gaps in these standards and guidelines and to recommend further development as necessary. This paper provides a summary of the standards and guidelines evaluated for applicability to DOE's Remedial Action programs. 33 references, 5 tables

  7. NAGC Pre-K-Grade 12 Gifted Education Programming Standards: A Guide to Planning and Implementing High-Quality Services

    Science.gov (United States)

    Johnsen, Susan K., Ed.

    2012-01-01

    The new Pre-K-Grade 12 Gifted Education Programming Standards should be part of every school district's repertoire of standards to ensure that the learning needs of advanced students are being met. "NAGC Pre-K-Grade 12 Gifted Education Programming Standards: A Guide to Planning and Implementing High-Quality Services" details six standards that…

  8. International Review of the Development and Implementation of Energy Efficiency Standards and Labeling Programs

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Nan; Zheng, Nina; Fridley, David

    2012-02-28

    Appliance energy efficiency standards and labeling (S&L) programs have been important policy tools for regulating the efficiency of energy-using products for over 40 years and continue to expand in terms of geographic and product coverage. The most common S&L programs include mandatory minimum energy performance standards (MEPS) that seek to push the market for efficient products, and energy information and endorsement labels that seek to pull the market. This study seeks to review and compare some of the earliest and most well-developed S&L programs in three countries and one region: the U.S. MEPS and ENERGY STAR, Australia MEPS and Energy Label, European Union MEPS and Ecodesign requirements and Energy Label and Japanese Top Runner programs. For each program, key elements of S&L programs are evaluated and comparative analyses across the programs undertaken to identify best practice examples of individual elements as well as cross-cutting factors for success and lessons learned in international S&L program development and implementation. The international review and comparative analysis identified several overarching themes and highlighted some common factors behind successful program elements. First, standard-setting and programmatic implementation can benefit significantly from a legal framework that stipulates a specific timeline or schedule for standard-setting and revision, product coverage and legal sanctions for non-compliance. Second, the different MEPS programs revealed similarities in targeting efficiency gains that are technically feasible and economically justified as the principle for choosing a standard level, in many cases at a level that no product on the current market could reach. Third, detailed survey data such as the U.S. Residential Energy Consumption Survey (RECS) and rigorous analyses provide a strong foundation for standard-setting while incorporating the participation of different groups of stakeholders further strengthen the process

  9. Reliability and safety analysis methodology in the nuclear programs of ERDA

    International Nuclear Information System (INIS)

    Hannum, W.H.; Gavigan, F.X.; Emon, D.E.

    1976-01-01

    After discussing the general need for and advantages of risk analysis, including a summary of the previous application of risk concepts to reactor systems, descriptions are given of the existing and planned programs funded by the U.S. Energy Research and Development Administration for use in advanced nuclear reactor systems. Some of the results from existing programs are given, and future efforts are described. 32 refs

  10. A cost-efficient and reliable energy management of a micro-grid using intelligent demand-response program

    International Nuclear Information System (INIS)

    Safamehr, Hossein; Rahimi-Kian, Ashkan

    2015-01-01

    Providing a cost-efficient and reliable energy is one of the main issues in human societies of the 21st century. In response to this demand, new features of micro grid technology have provided huge potentials, specifically by the capability of having an interactive coordination between energy suppliers and consumers. Accordingly, this paper offers an improved model for achieving an optimal Demand Response programing. To solve the proposed multi-objective optimization problem, Artificial Bee Colony algorithm and quasi-static technique are utilized. The considered objectives in this paper are minimizing the overall cost of energy consumption and also improving the technical parameters of micro grid over a time horizon. This optimization is subject to several constraints such as satisfying the energy balance and the operating constraints of each energy supply sources. Manageable load or load as source is another enabling feature existing in smart energy networks, which is considered in this paper and its effect on cost reduction and reliability improvement is studied. Trying to examine the performance of the proposed Demand Response Programing in real conditions, the uncertainties are also analyzed by stochastic methods. The results show significant improvements which are obtained by applying just intelligent programming and management. - Highlights: • This paper presents a cost-efficient and reliable energy management of a micro-grid. • New models of battery and manageable loads are formulated. • Artificial Bee Colony algorithm is used to solve the optimization problem. • Quasi-static technique is used to simplify the solving procedure. • The uncertainties are also analyzed by stochastic methods.

  11. Reliability of nine programs of topological predictions and their application to integral membrane channel and carrier proteins.

    Science.gov (United States)

    Reddy, Abhinay; Cho, Jaehoon; Ling, Sam; Reddy, Vamsee; Shlykov, Maksim; Saier, Milton H

    2014-01-01

    We evaluated topological predictions for nine different programs, HMMTOP, TMHMM, SVMTOP, DAS, SOSUI, TOPCONS, PHOBIUS, MEMSAT-SVM (hereinafter referred to as MEMSAT), and SPOCTOPUS. These programs were first evaluated using four large topologically well-defined families of secondary transporters, and the three best programs were further evaluated using topologically more diverse families of channels and carriers. In the initial studies, the order of accuracy was: SPOCTOPUS > MEMSAT > HMMTOP > TOPCONS > PHOBIUS > TMHMM > SVMTOP > DAS > SOSUI. Some families, such as the Sugar Porter Family (2.A.1.1) of the Major Facilitator Superfamily (MFS; TC #2.A.1) and the Amino Acid/Polyamine/Organocation (APC) Family (TC #2.A.3), were correctly predicted with high accuracy while others, such as the Mitochondrial Carrier (MC) (TC #2.A.29) and the K(+) transporter (Trk) families (TC #2.A.38), were predicted with much lower accuracy. For small, topologically homogeneous families, SPOCTOPUS and MEMSAT were generally most reliable, while with large, more diverse superfamilies, HMMTOP often proved to have the greatest prediction accuracy. We next developed a novel program, TM-STATS, that tabulates HMMTOP, SPOCTOPUS or MEMSAT-based topological predictions for any subdivision (class, subclass, superfamily, family, subfamily, or any combination of these) of the Transporter Classification Database (TCDB; www.tcdb.org) and examined the following subclasses: α-type channel proteins (TC subclasses 1.A and 1.E), secreted pore-forming toxins (TC subclass 1.C) and secondary carriers (subclass 2.A). Histograms were generated for each of these subclasses, and the results were analyzed according to subclass, family and protein. The results provide an update of topological predictions for integral membrane transport proteins as well as guides for the development of more reliable topological prediction programs, taking family-specific characteristics into account. © 2014 S. Karger AG, Basel.

  12. A review of standardized patients in clinical education: Implications for speech-language pathology programs.

    Science.gov (United States)

    Hill, Anne E; Davidson, Bronwyn J; Theodoros, Deborah G

    2010-06-01

    The use of standardized patients has been reported as a viable addition to traditional models of professional practice education in medicine, nursing and allied health programs. Educational programs rely on the inclusion of work-integrated learning components in order to graduate competent practitioners. Allied health programs world-wide have reported increasing difficulty in attaining sufficient traditional placements for students within the workplace. In response to this, allied health professionals are challenged to be innovative and problem-solving in the development and maintenance of clinical education placements and to consider potential alternative learning opportunities for students. Whilst there is a bank of literature describing the use of standardized patients in medicine and nursing, reports of its use in speech-language pathology clinical education are limited. Therefore, this paper aims to (1) provide a review of literature reporting on the use of standardized patients within medical and allied health professions with particular reference to use in speech-language pathology, (2) discuss methodological and practical issues involved in establishing and maintaining a standardized patient program and (3) identify future directions for research and clinical programs using standardized patients to build foundation clinical skills such as communication, interpersonal interaction and interviewing.

  13. Reliability and Availability Analysis of Some Systems with Common-Cause Failures Using SPICE Circuit Simulation Program

    Directory of Open Access Journals (Sweden)

    Muhammad Taher Abuelma'atti

    1999-01-01

    Full Text Available The effectiveness of SPICE circuit simulation program in calculating probabilities, reliability, steady-state availability and mean-time to failure of repairable systems described by Markov models is demonstrated. Two examples are presented. The first example is a warm standby system with common-cause failures and human errors. The second example is a non-identical unit parallel system with common-cause failures. In both cases recourse to numerical solution is inevitable to obtain the Laplace transforms of the probabilities. Results obtained using SPICE are compared with previously published results obtained using the Laplace transform method. Full SPICE listings are included.

  14. An accelerated stress testing program for determining the reliability sensitivity of silicon solar cells to encapsulation and metallization systems

    Science.gov (United States)

    Lathrop, J. W.; Davis, C. W.; Royal, E.

    1982-01-01

    The use of accelerated testing methods in a program to determine the reliability attributes of terrestrial silicon solar cells is discussed. Different failure modes are to be expected when cells with and without encapsulation are subjected to accelerated testing and separate test schedules for each are described. Unencapsulated test cells having slight variations in metallization are used to illustrate how accelerated testing can highlight different diffusion related failure mechanisms. The usefulness of accelerated testing when applied to encapsulated cells is illustrated by results showing that moisture related degradation may be many times worse with some forms of encapsulation than with no encapsulation at all.

  15. Standing Up a Narcotic Confirmation Laboratory for the Russian Federation Ministry of Defense Nuclear Personnel Reliability Program

    International Nuclear Information System (INIS)

    Lukyanenko, Victor; Eisele, Gerhard R.; Coates, Cameron W.

    2010-01-01

    Through a cooperative effort between the U. S. Department of Energy and the Russian Federation (RF) Ministry of Defense (MOD) a Personnel Reliability Program (PRP) for the nuclear handlers within the RF MOD has been implemented. A key element in the RF MOD PRP is the detection and confirmation of narcotic use in subject military and civilian personnel. This paper describes the process of narcotics screening and testing in the RF MOD and explains the confirmation process once screening has shown a positive result. Issues of laboratory certification, employee certification, employee training, sample chain-of-custody, and equipment needs will be addressed.

  16. The effect of state renewable portfolio standards on consumer participation in green pricing programs

    Science.gov (United States)

    Maltese, James L.

    In the last several years, two mechanisms for increasing the supply of renewable electricity have become increasingly popular: renewable portfolio standards, a state policy of mandating increased production of green power; and green pricing programs, which allow customers to purchase green power through their utilities. These mechanisms have been effective in increasing the adoption of renewable energy; however, it is unclear whether they interact in a way that is mutually beneficial or counterproductive. It is important to understand the effect of renewable portfolio standards on the voluntary market for green energy, especially as Congress considers a nationwide portfolio standard. The effectiveness of a renewable portfolio standard may be undercut if it leads customers to purchase less green power. This study analyzes the relationship between the passage and implementation of a renewable portfolio standard and two measures of enrollment in utility green pricing programs. Using eight years of data for all fifty states, the study utilizes multiple regression analysis with fixed-effects estimation. The results indicate that the passage of a renewable portfolio standard has a positive and statistically significant effect on green pricing enrollment within the state. At the same time, the rate at which states increase the stringency of the renewable portfolio standard is found to have no effect on enrollment. Although further study is needed to determine if additional factors are responsible for the observed increase in green pricing enrollment, this study provides evidence that such programs do not harm, and may in fact encourage, voluntary purchases of green power.

  17. Alternative Renewable Biomass Tracking Program Document under the Renewable Fuel Standard Program

    Science.gov (United States)

    The approval letters that EPA approves a company's biomass tracking program meeting all the requirements outlined in 40 CFR part 80.1454, including elements determined necessary to achieve the level of quality assurance required under the regulation list.

  18. Maximizing Energy Savings Reliability in BC Hydro Industrial Demand-side Management Programs: An Assessment of Performance Incentive Models

    Science.gov (United States)

    Gosman, Nathaniel

    For energy utilities faced with expanded jurisdictional energy efficiency requirements and pursuing demand-side management (DSM) incentive programs in the large industrial sector, performance incentive programs can be an effective means to maximize the reliability of planned energy savings. Performance incentive programs balance the objectives of high participation rates with persistent energy savings by: (1) providing financial incentives and resources to minimize constraints to investment in energy efficiency, and (2) requiring that incentive payments be dependent on measured energy savings over time. As BC Hydro increases its DSM initiatives to meet the Clean Energy Act objective to reduce at least 66 per cent of new electricity demand with DSM by 2020, the utility is faced with a higher level of DSM risk, or uncertainties that impact the costeffective acquisition of planned energy savings. For industrial DSM incentive programs, DSM risk can be broken down into project development and project performance risks. Development risk represents the project ramp-up phase and is the risk that planned energy savings do not materialize due to low customer response to program incentives. Performance risk represents the operational phase and is the risk that planned energy savings do not persist over the effective measure life. DSM project development and performance risks are, in turn, a result of industrial economic, technological and organizational conditions, or DSM risk factors. In the BC large industrial sector, and characteristic of large industrial sectors in general, these DSM risk factors include: (1) capital constraints to investment in energy efficiency, (2) commodity price volatility, (3) limited internal staffing resources to deploy towards energy efficiency, (4) variable load, process-based energy saving potential, and (5) a lack of organizational awareness of an operation's energy efficiency over time (energy performance). This research assessed the capacity

  19. Review of cause-based decision tree approach for the development of domestic standard human reliability analysis procedure in low power/shutdown operation probabilistic safety assessment

    International Nuclear Information System (INIS)

    Kang, D. I.; Jung, W. D.

    2003-01-01

    We review the Cause-Based Decision Tree (CBDT) approach to decide whether we incorporate it or not for the development of domestic standard Human Reliability Analysis (HRA) procedure in low power/shutdown operation Probabilistic Safety Assessment (PSA). In this paper, we introduce the cause based decision tree approach, quantify human errors using it, and identify merits and demerits of it in comparision with previously used THERP. The review results show that it is difficult to incorporate the CBDT method for the development of domestic standard HRA procedure in low power/shutdown PSA because the CBDT method need for the subjective judgment of HRA analyst like as THERP. However, it is expected that the incorporation of the CBDT method into the development of domestic standard HRA procedure only for the comparision of quantitative HRA results will relieve the burden of development of detailed HRA procedure and will help maintain consistent quantitative HRA results

  20. High-reliability logic system evaluation of a programmed multiprocessor solution. Application in the nuclear reactor safety field

    International Nuclear Information System (INIS)

    Lallement, Dominique.

    1979-01-01

    Nuclear reactors are monitored by several systems combined. The hydraulic and mechanical limitations on the equipment and the heat transfer requirements in the core set a reliable working range for the boiler defined with certain safety margins. The control system tends to keep the power plant within this working range. The protection system covers all the electrical and mechanical equipment needed to safeguard the boiler in the event of abnormal transients or accidents accounted for in the design of the plant. On units in service protection is handled by cabled automatic systems. For better reliability and safety operation, greater flexibility of use (modularity, adaptability) and improved start-up criteria by data processing the tendency is to use digital programmed systems. Computers are already present in control systems but their introduction into protection systems meets with some reticence on the part of the nuclear safety authorities. A study on the replacement of conventional by digital protection systems is presented. From choices partly made on the principles which should govern the hardware and software of a protection system the reliability of different structures and elements was examined and an experimental model built with its simulator and test facilities. A prototype based on these options and studies is being built and is to be set up on one of the CEN-G reactors for tests [fr

  1. An enhanced reliability-oriented workforce planning model for process industry using combined fuzzy goal programming and differential evolution approach

    Science.gov (United States)

    Ighravwe, D. E.; Oke, S. A.; Adebiyi, K. A.

    2018-03-01

    This paper draws on the "human reliability" concept as a structure for gaining insight into the maintenance workforce assessment in a process industry. Human reliability hinges on developing the reliability of humans to a threshold that guides the maintenance workforce to execute accurate decisions within the limits of resources and time allocations. This concept offers a worthwhile point of deviation to encompass three elegant adjustments to literature model in terms of maintenance time, workforce performance and return-on-workforce investments. These fully explain the results of our influence. The presented structure breaks new grounds in maintenance workforce theory and practice from a number of perspectives. First, we have successfully implemented fuzzy goal programming (FGP) and differential evolution (DE) techniques for the solution of optimisation problem in maintenance of a process plant for the first time. The results obtained in this work showed better quality of solution from the DE algorithm compared with those of genetic algorithm and particle swarm optimisation algorithm, thus expressing superiority of the proposed procedure over them. Second, the analytical discourse, which was framed on stochastic theory, focusing on specific application to a process plant in Nigeria is a novelty. The work provides more insights into maintenance workforce planning during overhaul rework and overtime maintenance activities in manufacturing systems and demonstrated capacity in generating substantially helpful information for practice.

  2. Validity and reliability of 3D US for the detection of erosions in patients with rheumatoid arthritis using MRI as the gold standard

    DEFF Research Database (Denmark)

    Ellegaard, K; Bliddal, H; Møller Døhn, U

    2014-01-01

    PURPOSE: To test the reliability and validity of a 3D US erosion score in RA using MRI as the gold standard. MATERIALS AND METHODS: RA patients were examined with 3D US and 3 T MRI over the 2nd and 3rd metacarpophalangeal joints. 3D blocks were evaluated by two investigators. The erosions were...... estimated according to a semi-quantitative score (SQS) (0 - 3) and a quantitative score (QS) (mm²). MRI was evaluated according to the RAMRIS score. For the estimation of reliability, intra-class correlation coefficients (ICC) were used. Validity was tested using Spearman's rho (rs). The sensitivity...... and specificity were also calculated. RESULTS: 28 patients with RA were included. The ICC for the inter-observer reliability in the QS was 0.41 and 0.13 for the metacarpal bone and phalangeal bone, respectively, and 0.86 and 0.16, respectively, in the SQS.  The ICC for the intra-observer reliability in the QS...

  3. An investigation into the minimum accelerometry wear time for reliable estimates of habitual physical activity and definition of a standard measurement day in pre-school children.

    Science.gov (United States)

    Hislop, Jane; Law, James; Rush, Robert; Grainger, Andrew; Bulley, Cathy; Reilly, John J; Mercer, Tom

    2014-11-01

    The purpose of this study was to determine the number of hours and days of accelerometry data necessary to provide a reliable estimate of habitual physical activity in pre-school children. The impact of a weekend day on reliability estimates was also determined and standard measurement days were defined for weekend and weekdays.Accelerometry data were collected from 112 children (60 males, 52 females, mean (SD) 3.7 (0.7)yr) over 7 d. The Spearman-Brown Prophecy formula (S-B prophecy formula) was used to predict the number of days and hours of data required to achieve an intraclass correlation coefficient (ICC) of 0.7. The impact of including a weekend day was evaluated by comparing the reliability coefficient (r) for any 4 d of data with data for 4 d including one weekend day.Our observations indicate that 3 d of accelerometry monitoring, regardless of whether it includes a weekend day, for at least 7 h  d(-1) offers sufficient reliability to characterise total physical activity and sedentary behaviour of pre-school children. These findings offer an approach that addresses the underlying tension in epidemiologic surveillance studies between the need to maintain acceptable measurement rigour and retention of a representatively meaningful sample size.

  4. Impact of standards and certification on environmental impairment liability insurance programs

    International Nuclear Information System (INIS)

    Gulledge, W.P.

    1993-01-01

    Environmental impairment liability (EIL) insurance is available for petroleum storage tank and other environmental exposures. Recent standards and performance criteria for leak detection for underground storage tanks (USTs) and other technical standards for USTs have been both a benefit and an interference to risk-based underwriting of storage tank EIL insurance programs. Insurance underwriters and state financial responsibility program administrators are confronted with confusing information to manage these environmental risks. Standards and certification are also key issues for site assessment programs. Recent activities from ASTM and the Institute for Environmental Auditing (IEA) have addressed the need to increase the professional stature of site assessments and environmental management. Reaction and acceptance of these efforts by the users have been mixed. Ultimately, these efforts will greatly impact insurance coverage for environmental risks

  5. Self-Reliability and Motivation in a Nuclear Security Culture Enhancement Program

    Energy Technology Data Exchange (ETDEWEB)

    Rogers,E.; deBoer,G.; Crawford, C.; De Castro, K.; Landers, J.

    2009-10-19

    The threat of nuclear terrorism has become a global concern. Many countries continue to make efforts to strengthen nuclear security by enhancing systems of nuclear material protection, control, and accounting (MPC&A). Though MPC&A systems can significantly upgrade nuclear security, they do not eliminate the "human factor." Gen. Eugene Habiger, a former "Assistant Secretary for Safeguards and Security" at the U.S. Department of Energy’s (DOE) nuclear-weapons complex and a former commander of U.S. strategic nuclear forces, has observed that "good security is 20% equipment and 80% people." Although eliminating the "human factor" is not possible, accounting for and mitigating the risk of the insider threat is an essential element in establishing an effective nuclear security culture. This paper will consider the organizational role in mitigating the risk associated with the malicious insider through monitoring and enhancing human reliability and motivation as well as enhancing the nuclear security culture.

  6. Self-Reliability and Motivation in a Nuclear Security Culture Enhancement Program

    International Nuclear Information System (INIS)

    Rogers, E.; deBoer, G.; Crawford, C.; De Castro, K.; Landers, J.

    2009-01-01

    The threat of nuclear terrorism has become a global concern. Many countries continue to make efforts to strengthen nuclear security by enhancing systems of nuclear material protection, control, and accounting (MPC and A). Though MPC and A systems can significantly upgrade nuclear security, they do not eliminate the 'human factor.' Gen. Eugene Habiger, a former 'Assistant Secretary for Safeguards and Security' at the U.S. Department of Energy's (DOE) nuclear-weapons complex and a former commander of U.S. strategic nuclear forces, has observed that 'good security is 20% equipment and 80% people.' Although eliminating the 'human factor' is not possible, accounting for and mitigating the risk of the insider threat is an essential element in establishing an effective nuclear security culture. This paper will consider the organizational role in mitigating the risk associated with the malicious insider through monitoring and enhancing human reliability and motivation as well as enhancing the nuclear security culture.

  7. A multi-objective reliable programming model for disruption in supply chain

    Directory of Open Access Journals (Sweden)

    Emran Mohammadi

    2013-05-01

    Full Text Available One of the primary concerns on supply chain management is to handle risk components, properly. There are various reasons for having risk in supply chain such as natural disasters, unexpected incidents, etc. When a series of facilities are built and deployed, one or a number of them could probably fail at any time due to bad weather conditions, labor strikes, economic crises, sabotage or terrorist attacks and changes in ownership of the system. The objective of risk management is to reduce the effects of different domains to an acceptable level. To overcome the risk, we propose a reliable capacitated supply chain network design (RSCND model by considering random disruptions risk in both distribution centers and suppliers. The proposed study of this paper considers three objective functions and the implementation is verified using some instance.

  8. Risk programming and sparse data: how to get more reliable results

    NARCIS (Netherlands)

    Hardaker, J.B.; Lien, G.; Asseldonk, van M.A.P.M.; Richardson, W.; Hegrenes, A.

    2008-01-01

    Because relevant historical data for farms are inevitably sparse, most risk programming studies rely on few observations. We discuss how to use available information to derive an appropriate multivariate distribution function that can be sampled for a more complete representation of the possible

  9. Review of standards and guidelines pertinent to DOE's Remedial Action programs

    International Nuclear Information System (INIS)

    Soldat, J.K.; Denham, D.H.

    1985-01-01

    A number of radiological standards, guidelines, and dose criteria have been promulgated that may be relevant to the Department of Energy's (DOE) Remedial Action programs. Some of these are being applied to remedial actions undertaken by DOE to ensure that health and safety aspects are adequately addressed. Pacific Northwest Laboratory staff reviewed existing and proposed environmental radiological standards and criteria for their applicability to DOE's Remedial Action Programs. National and international environmental standards and criteria, and studies conducted by other DOE contractors were reviewed. The review indicated that there is a lack of uniformity between the dose guidelines developed by the various agencies. A uniform dose standard is needed for DandD, at least as an upper limit with application of the ALARA philosophy. 33 references, 5 tables

  10. ISO/IEC 17025 laboratory accreditation of NRC Acoustical Standards Program

    Science.gov (United States)

    Wong, George S. K.; Wu, Lixue; Hanes, Peter; Ohm, Won-Suk

    2004-05-01

    Experience gained during the external accreditation of the Acoustical Standards Program at the Institute for National Measurement Standards of the National Research Council is discussed. Some highlights include the preparation of documents for calibration procedures, control documents with attention to reducing future paper work and the need to maintain documentation or paper trails to satisfy the external assessors. General recommendations will be given for laboratories that are contemplating an external audit in accordance to the requirements of ISO/IEC 17025.

  11. SCINFI II A program to calculate the standardization curve in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    1985-07-01

    A code, SCINFI II, written in BASIC, has been developed to compute the efficiency-quench standardization curve for any beta radionuclide. The free parameter method has been applied. The program requires the standardization curve for 3{sup H} and the polynomial or tabulated relating counting efficiency as figure of merit for both 3{sup H} and the problem radionuclide. The program is applied to the computation, of the counting efficiency for different values of quench when the problem is 14{sup C}. The results of four different computation methods are compared. (Author) 17 refs.

  12. SCINFI II A program to calculate the standardization curve in liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1985-01-01

    A code, SCINFI II, written in BASIC, has been developed to compute the efficiency-quench standardization curve for any beta radionuclide. The free parameter method has been applied. The program requires the standardization curve for 3 H and the polynomial or tabulated relating counting efficiency as figure of merit for both 3 H and the problem radionuclide. The program is applied to the computation, of the counting efficiency for different values of quench when the problem is 14 C . The results of four different computation methods are compared. (Author) 17 refs

  13. Design of Standards and Labeling programs in Chile: Techno-Economic Analysis for Refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Letschert, Virginie E. [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division.; McNeil, Michael A. [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division.; Pavon, Mariana [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division.; Lutz, Wolfgang F. [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division.

    2013-05-01

    Lawrence Berkeley National Laboratory is a global leader in the study of energy efficiency and its effective implementation through government policy. The Energy Analysis and Environmental Impacts Department of LBNL’s Environmental Energy Technologies Division provides technical assistance to help federal, stat e and local government agencies in the United States, and throughout the world, develop long-term strategies, policy, and programs to encourage energy efficiency in all sectors and industries. In the past, LBNL has assisted staff of various countries government agencies and their con tractors in providing methodologies to analyze cost-effectiveness of regulations and asses s overall national impacts of efficiency programs. The paper presents the work done in collaboration with the Ministry of Energy (MoE) in Chile and the Collaborative Labeling Appliance Standards Programs (CLASP) on designing a Minimum Energy Performance Standards (MEPS) and ext ending the current labeling program for refrigerators.

  14. The standard calibration instrument automation system for the atomic absorption spectrophotometer. Part 3: Program documentation

    Science.gov (United States)

    Ryan, D. P.; Roth, G. S.

    1982-04-01

    Complete documentation of the 15 programs and 11 data files of the EPA Atomic Absorption Instrument Automation System is presented. The system incorporates the following major features: (1) multipoint calibration using first, second, or third degree regression or linear interpolation, (2) timely quality control assessments for spiked samples, duplicates, laboratory control standards, reagent blanks, and instrument check standards, (3) reagent blank subtraction, and (4) plotting of calibration curves and raw data peaks. The programs of this system are written in Data General Extended BASIC, Revision 4.3, as enhanced for multi-user, real-time data acquisition. They run in a Data General Nova 840 minicomputer under the operating system RDOS, Revision 6.2. There is a functional description, a symbol definitions table, a functional flowchart, a program listing, and a symbol cross reference table for each program. The structure of every data file is also detailed.

  15. Battelle integrity of nuclear piping program. Summary of results and implications for codes/standards

    International Nuclear Information System (INIS)

    Miura, Naoki

    2005-01-01

    The BINP(Battelle Integrity of Nuclear Piping) program was proposed by Battelle to elaborate pipe fracture evaluation methods and to improve LBB and in-service flaw evaluation criteria. The program has been conducted from October 1998 to September 2003. In Japan, CRIEPI participated in the program on behalf of electric utilities and fabricators to catch up the technical backgrounds for possible future revision of LBB and in-service flaw evaluation standards and to investigate the issues needed to be reflected to current domestic standards. A series of the results obtained from the program has been well utilized for the new LBB Regulatory Guide Program by USNRC and for proposal of revised in-service flaw evaluation criteria to the ASME Code Committee. The results were assessed whether they had implications for the existing or future domestic standards. As a result, the impact of many of these issues, which were concerned to be adversely affected to LBB approval or allowable flaw sizes in flaw evaluation criteria, was found to be relatively minor under actual plant conditions. At the same time, some issues that needed to be resolved to address advanced and rational standards in the future were specified. (author)

  16. Developing Standards for Language Teacher Education Programs in Indonesia: Professionalizing or Losing in Complexity?

    Directory of Open Access Journals (Sweden)

    Luciana Luciana

    2004-01-01

    Full Text Available Setting standards for language teacher education programs, materials, and evaluation sparks some hope in attempts to improve the quality of the programs. Yet, this very fact augmented by my examination of ten language teacher education programs in Java, Bali, and Lampung (FKIP and PGRI triggers a critical look at the idea of standard development. In particular, I would like to explore whether it can lead to a better professionalism or we are just lost in the complexity of the standardization itself. This paper consists of four sections. Departing from an overview of language teacher education programs in Indonesia and the theoretical foundations, some major problems in this area are identified. Following this, the discussion is focused on the idea of standard development for language teacher education programs in Indonesia. Eventually, some suggestions are put forth to highlight the need for establishing coherent curriculum framework bridging the two realms of language teacher education and school milieu as well as providing learners with knowledge base that enables them to cope with complex demands of school settings and more essentially, to act as an agent in the social change process.

  17. Factors That Influence Standard Automated Perimetry Test Results in Glaucoma : Test Reliability, Technician Experience, Time of Day, and Season

    NARCIS (Netherlands)

    Montolio, Francisco G. Junoy; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M.

    2012-01-01

    PURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience,

  18. Factors that influence standard automated perimetry test results in glaucoma: Test reliability, technician experience, time of day, and season

    NARCIS (Netherlands)

    F.G.J. Montolio (Francisco G. Junoy); C. Wesselink (Christiaan); M.C.M. Gordijn (Marijke); N.M. Jansonius (Nomdo)

    2012-01-01

    textabstractPURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician

  19. High-temperature gas-cooled reactor safety-reliability program plan

    Energy Technology Data Exchange (ETDEWEB)

    1981-03-01

    The purpose of this document is to present a safety plan as part of an overall program plan for the design and development of the High Temperature Gas-Cooled Reactor (HTGR). This plan is intended to establish a logical framework for identifying the technology necessary to demonstrate that the requisite degree of public risk safety can be achieved economically. This plan provides a coherent system safety approach together with goals and success criterion as part of a unifying strategy for licensing a lead reactor plant in the near term. It is intended to provide guidance to program participants involved in producing a technology base for the HTGR that is fully responsive to safety consideration in the design, evaluation, licensing, public acceptance, and economic optimization of reactor systems.

  20. Risk programming and sparse data: how to get more reliable results

    OpenAIRE

    Hardaker, J. Brian; Lien, Gudbrand D.; Van Asseldonk, Marcel A.P.M.; Richardson, James W.; Hegrenes, Agnar

    2008-01-01

    Because relevant historical data for farms are inevitably sparse, most risk programming studies rely on few observations. We discuss how to use available information to derive an appropriate multivariate distribution function that can be sampled for a more complete representation of the possible risks in riskbased models. For the particular example of a Norwegian mixed livestock and crop farm, the solution is shown to be unstable with few states, although the cost of picking a sub-optimal pla...

  1. Self-Reliability and Motivation in a Nuclear Security Culture Enhancement Program

    Energy Technology Data Exchange (ETDEWEB)

    Crawford,C.; de Boer,G.; De Castro, K; Landers, Ph.D., J; Rogers, E

    2009-10-19

    The threat of nuclear terrorism has become a global concern. Many countries continue to make efforts to strengthen nuclear security by enhancing systems of nuclear material protection, control, and accounting (MPC&A). Though MPC&A systems can significantly upgrade nuclear security, they do not eliminate the "human factor." This paper will describe some of the key elements of a comprehensive, sustainable nuclear security culture enhancement program and how implementation can mitigate the insider threat.

  2. Reliability engineering

    International Nuclear Information System (INIS)

    Lee, Chi Woo; Kim, Sun Jin; Lee, Seung Woo; Jeong, Sang Yeong

    1993-08-01

    This book start what is reliability? such as origin of reliability problems, definition of reliability and reliability and use of reliability. It also deals with probability and calculation of reliability, reliability function and failure rate, probability distribution of reliability, assumption of MTBF, process of probability distribution, down time, maintainability and availability, break down maintenance and preventive maintenance design of reliability, design of reliability for prediction and statistics, reliability test, reliability data and design and management of reliability.

  3. 78 FR 9529 - National School Lunch Program and School Breakfast Program: Nutrition Standards for All Foods...

    Science.gov (United States)

    2013-02-08

    ... collection burden inventory for the National School Lunch Program is 12,181,012. These changes are contingent... American children and adolescents: What changes in prevalence rates could not reveal. International Journal... purchase and consume at school. Researchers concluded that these kinds of changes in food exposure and...

  4. Reliability and Validity of the Sensory Component of the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI): A Systematic Review

    Science.gov (United States)

    Hales, M.; Biros, E.

    2015-01-01

    Background: Since 1982, the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI) has been used to classify sensation of spinal cord injury (SCI) through pinprick and light touch scores. The absence of proprioception, pain, and temperature within this scale creates questions about its validity and accuracy. Objectives: To assess whether the sensory component of the ISNCSCI represents a reliable and valid measure of classification of SCI. Methods: A systematic review of studies examining the reliability and validity of the sensory component of the ISNCSCI published between 1982 and February 2013 was conducted. The electronic databases MEDLINE via Ovid, CINAHL, PEDro, and Scopus were searched for relevant articles. A secondary search of reference lists was also completed. Chosen articles were assessed according to the Oxford Centre for Evidence-Based Medicine hierarchy of evidence and critically appraised using the McMasters Critical Review Form. A statistical analysis was conducted to investigate the variability of the results given by reliability studies. Results: Twelve studies were identified: 9 reviewed reliability and 3 reviewed validity. All studies demonstrated low levels of evidence and moderate critical appraisal scores. The majority of the articles (~67%; 6/9) assessing the reliability suggested that training was positively associated with better posttest results. The results of the 3 studies that assessed the validity of the ISNCSCI scale were confounding. Conclusions: Due to the low to moderate quality of the current literature, the sensory component of the ISNCSCI requires further revision and investigation if it is to be a useful tool in clinical trials. PMID:26363591

  5. Electronic laboratory quality assurance program: A method of enhancing the prosthodontic curriculum and addressing accreditation standards.

    Science.gov (United States)

    Moghadam, Marjan; Jahangiri, Leila

    2015-08-01

    An electronic quality assurance (eQA) program was developed to replace a paper-based system and to address standards introduced by the Commission on Dental Accreditation (CODA) and to improve educational outcomes. This eQA program provides feedback to predoctoral dental students on prosthodontic laboratory steps at New York University College of Dentistry. The purpose of this study was to compare the eQA program of performing laboratory quality assurance with the former paper-based format. Fourth-year predoctoral dental students (n=334) who experienced both the paper-based and the electronic version of the quality assurance program were surveyed about their experiences. Additionally, data extracted from the eQA program were analyzed to identify areas of weakness in the curriculum. The study findings revealed that 73.8% of the students preferred the eQA program to the paper-based version. The average number of treatments that did not pass quality assurance standards was 119.5 per month. This indicated a 6.34% laboratory failure rate. Further analysis of these data revealed that 62.1% of the errors were related to fixed prosthodontic treatment, 27.9% to partial removable dental prostheses, and 10% to complete removable dental prostheses in the first 18 months of program implementation. The eQA program was favored by dental students who have experienced both electronic and paper-based versions of the system. Error type analysis can yield the ability to create customized faculty standardization sessions and refine the didactic and clinical teaching of the predoctoral students. This program was also able to link patient care activity with the student's laboratory activities, thus addressing the latest requirements of the CODA regarding the competence of graduates in evaluating laboratory work related to their patient care. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Standard error of measurement of 5 health utility indexes across the range of health for use in estimating reliability and responsiveness.

    Science.gov (United States)

    Palta, Mari; Chen, Han-Yang; Kaplan, Robert M; Feeny, David; Cherepanov, Dasha; Fryback, Dennis G

    2011-01-01

    Standard errors of measurement (SEMs) of health-related quality of life (HRQoL) indexes are not well characterized. SEM is needed to estimate responsiveness statistics, and is a component of reliability. To estimate the SEM of 5 HRQoL indexes. The National Health Measurement Study (NHMS) was a population-based survey. The Clinical Outcomes and Measurement of Health Study (COMHS) provided repeated measures. A total of 3844 randomly selected adults from the noninstitutionalized population aged 35 to 89 y in the contiguous United States and 265 cataract patients. The SF6-36v2™, QWB-SA, EQ-5D, HUI2, and HUI3 were included. An item-response theory approach captured joint variation in indexes into a composite construct of health (theta). The authors estimated 1) the test-retest standard deviation (SEM-TR) from COMHS, 2) the structural standard deviation (SEM-S) around theta from NHMS, and 3) reliability coefficients. SEM-TR was 0.068 (SF-6D), 0.087 (QWB-SA), 0.093 (EQ-5D), 0.100 (HUI2), and 0.134 (HUI3), whereas SEM-S was 0.071, 0.094, 0.084, 0.074, and 0.117, respectively. These yield reliability coefficients 0.66 (COMHS) and 0.71 (NHMS) for SF-6D, 0.59 and 0.64 for QWB-SA, 0.61 and 0.70 for EQ-5D, 0.64 and 0.80 for HUI2, and 0.75 and 0.77 for HUI3, respectively. The SEM varied across levels of health, especially for HUI2, HUI3, and EQ-5D, and was influenced by ceiling effects. Limitations. Repeated measures were 5 mo apart, and estimated theta contained measurement error. The 2 types of SEM are similar and substantial for all the indexes and vary across health.

  7. Intercoder Reliability of Mapping Between Pharmaceutical Dose Forms in the German Medication Plan and EDQM Standard Terms.

    Science.gov (United States)

    Sass, Julian; Becker, Kim; Ludmann, Dominik; Pantazoglou, Elisabeth; Dewenter, Heike; Thun, Sylvia

    2018-01-01

    A nationally uniform medication plan has recently been part of German legislation. The specification for the German medication plan was developed in cooperation between various stakeholders of the healthcare system. Its' goal is to enhance usability and interoperability while also providing patients and physicians with the necessary information they require for a safe and high-quality therapy. Within the research and development project named Medication Plan PLUS, the specification of the medication plan was tested and reviewed for semantic interoperability in particular. In this study, the list of pharmaceutical dose forms provided in the specification was mapped to the standard terms of the European Directorate for the Quality of Medicines & HealthCare by different coders. The level of agreement between coders was calculated using Cohen's Kappa (κ). Results show that less than half of the dose forms could be coded with EDQM standard terms. In addition to that Kappa was found to be moderate, which means rather unconvincing agreement among coders. In conclusion, there is still vast room for improvement in utilization of standardized international vocabulary and unused potential considering cross-border eHealth implementations in the future.

  8. Development of a reliable simulation-based test for diagnostic abdominal ultrasound with a pass/fail standard usable for mastery learning

    DEFF Research Database (Denmark)

    Østergaard, Mia L; Nielsen, Kristina R; Albrecht-Beste, Elisabeth

    2018-01-01

    training can benefit from competency-based education based on reliable tests. • This simulation-based test can differentiate between competency levels of ultrasound examiners. • This test is suitable for competency-based education, e.g. mastery learning. • We provide a pass/fail standard without false...... from The European Federation of Societies for Ultrasound in Medicine and Biology. Four groups of experience levels were constructed: Novices (medical students), trainees (first-year radiology residents), intermediates (third- to fourth-year radiology residents) and advanced (physicians with ultrasound...

  9. 76 FR 70547 - Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts

    Science.gov (United States)

    2011-11-14

    ... the term ``fluorescent lamp,'' which EPCA defines as ``a low pressure mercury electric-discharge... discharge into light,'' and as including the four enumerated types of fluorescent lamps for which EPCA... Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts; Final Rule #0;#0;Federal...

  10. Standards for Competence in Braille Literacy Skills in Teacher Preparation Programs.

    Science.gov (United States)

    Amato, Sheila

    2002-01-01

    A survey was conducted with 45 instructors from teacher training programs for teaching students with visual impairments. Respondents evidenced a strong commitment to Braille literacy and teacher preparation, however, findings indicate a lack of consistency in Braille courses with respect to standards and criteria for competence in Braille…

  11. 75 FR 21981 - Energy Conservation Program: Energy Conservation Standards for Residential Water Heaters, Direct...

    Science.gov (United States)

    2010-04-27

    ... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket Number EE-2006-BT-STD-0129] RIN 1904-AA90 Energy Conservation Program: Energy Conservation Standards for Residential Water Heaters, Direct Heating Equipment, and Pool Heaters Correction In rule document 2010-7611 beginning on page 20112 in the issue of Friday...

  12. Views of surgery program directors on the current ACGME and proposed IOM duty-hour standards.

    Science.gov (United States)

    Willis, Ross E; Coverdill, James E; Mellinger, John D; Collins, J Craig; Potts, John R; Dent, Daniel L

    2009-01-01

    The purpose of this study was to survey the experiences of surgery program directors with the current Accreditation Council for Graduate Medical Education (ACGME) duty-hour standards and views of the Institute of Medicine (IOM) proposed duty-hour recommendations. A total of 118 program directors (47.6% of all surgery programs in the US) responded to the survey. Results showed that the current duty-hour standards have hindered clinical education opportunities by reducing or eliminating rotations on many services, didactic teaching conferences, and clinical bedside teaching opportunities. Additionally, patient safety has been compromised by frequent hand offs of care. Most IOM recommendations were perceived as extremely difficult or impossible to implement, with the exception of the moonlighting recommendation. The results indicated that adopting the IOM recommendations is not feasible given current workforce limitations, and most program directors supported maintaining the current duty-hour standards until such time as there is evidence-based outcomes research to direct change. The conclusion was that the current ACGME duty-hour standards have reduced teaching opportunities and narrowed the scope of training.

  13. 78 FR 54197 - Energy Efficiency Program for Commercial and Industrial Equipment: Energy Conservation Standards...

    Science.gov (United States)

    2013-09-03

    .... EERE-2013-BT-STD-0030] RIN 1904-AD01 Energy Efficiency Program for Commercial and Industrial Equipment: Energy Conservation Standards for Commercial Packaged Boilers AGENCY: Office of Energy Efficiency and..., Office of Energy Efficiency and Renewable Energy, Building Technologies Office, EE-2J, 1000 Independence...

  14. 75 FR 31323 - Energy Efficiency Program: Energy Conservation Standards Furnace Fans: Public Meeting and...

    Science.gov (United States)

    2010-06-03

    .... EERE-2010-BT-STD-0011] RIN 1904-AC22 Energy Efficiency Program: Energy Conservation Standards Furnace Fans: Public Meeting and Availability of the Framework Document AGENCY: Office of Energy Efficiency and... Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies, EE-2J, 1000 Independence...

  15. 42 CFR Appendix A to Part 75 - Standards for Accreditation of Educational Programs for Radiographers

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Standards for Accreditation of Educational Programs for Radiographers A Appendix A to Part 75 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH... film evaluation; (k) Methods of patient care; (l) Pathology; (m) Radiologic physics; and (n) Radiation...

  16. APA Reporting Standards in Quantitative Research Dissertations from an Online EdD Program

    Science.gov (United States)

    Salgado, Griselle

    2013-01-01

    This study was an investigation of the reporting practices in dissertations with quantitative research designs produced by students enrolled in an online Doctor of Education (EdD) program, one that follows the American Psychological Association (APA) standards for reporting research. Limited, empirical information exists about the competencies in…

  17. 77 FR 53199 - California State Motor Vehicle Pollution Control Standards; Advanced Clean Car Program; Request...

    Science.gov (United States)

    2012-08-31

    ... cars, light-duty trucks and medium-duty passenger vehicles (and limited requirements related to heavy... ENVIRONMENTAL PROTECTION AGENCY [AMS-FRL-9724-4] California State Motor Vehicle Pollution Control Standards; Advanced Clean Car Program; Request for Waiver of Preemption; Opportunity for Public Hearing and...

  18. The Gold Standard Program for Smoking Cessation is Effective for Participants Over 60 Years of Age

    DEFF Research Database (Denmark)

    Flamand, Mette Kehlet; Schroeder, Torben V; Tønnesen, Hanne

    2015-01-01

    BACKGROUND: Tobacco smoking is more prevalent among the elderly than among the young, and the elderly also have the most frequent contact with the health care system. The aim of this study was to evaluate the effectiveness of the Gold Standard Program, which is an intensive six-week smoking...

  19. 13 CFR 121.402 - What size standards are applicable to Federal Government Contracting programs?

    Science.gov (United States)

    2010-01-01

    ... Size Eligibility Requirements for Government Procurement § 121.402 What size standards are applicable... being purchased. Other factors considered include previous Government procurement classifications of the... to Federal Government Contracting programs? 121.402 Section 121.402 Business Credit and Assistance...

  20. 78 FR 20842 - Energy Conservation Program: Energy Conservation Standards for Residential Clothes Dryers and...

    Science.gov (United States)

    2013-04-08

    ... DeLonghi); energy and environmental advocates (American Council for an Energy Efficient Economy (ACEEE... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket Number EERE-2013-BT-STD-0020] RIN 1904-AC98 Energy Conservation Program: Energy Conservation Standards for Residential Clothes Dryers and Room Air Conditioners...

  1. 25 CFR 36.12 - Standard III-Program needs assessment.

    Science.gov (United States)

    2010-04-01

    ...., (1) Perceptions of the parents, tribes, educators, and the students with regard to the relevance and....12 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR EDUCATION MINIMUM ACADEMIC STANDARDS... Program Evaluation. This assessment shall include at least the following: (a) A clear statement of student...

  2. 78 FR 25626 - Energy Conservation Program for Consumer Products: Energy Conservation Standards for Ceiling Fans...

    Science.gov (United States)

    2013-05-02

    ... Conservation Program for Consumer Products: Energy Conservation Standards for Ceiling Fans and Ceiling Fan... for residential ceiling fans and ceiling fan light kits in the Federal Register. This document... other aspect of the rulemaking for ceiling fans and ceiling fan light kits. The comment period is...

  3. Accomplishing PETE Learning Standards and Program Accreditation through Teacher Candidates' Technology-Based Service Learning Projects

    Science.gov (United States)

    Gibbone, Anne; Mercier, Kevin

    2014-01-01

    Teacher candidates' use of technology is a component of physical education teacher education (PETE) program learning goals and accreditation standards. The methods presented in this article can help teacher candidates to learn about and apply technology as an instructional tool prior to and during field or clinical experiences. The goal in…

  4. 25 CFR 36.50 - Standard XVII-School program evaluation and needs assessment.

    Science.gov (United States)

    2010-04-01

    ... MINIMUM ACADEMIC STANDARDS FOR THE BASIC EDUCATION OF INDIAN CHILDREN AND NATIONAL CRITERIA FOR DORMITORY... process evaluation methods. The areas to be reviewed will include, but not be limited to, the following... planning and implementation. (4) Curriculum development and instruction. (5) Primary education. (6) Program...

  5. 76 FR 18066 - Regulation of Fuels and Fuel Additives: Changes to Renewable Fuel Standard Program

    Science.gov (United States)

    2011-04-01

    ... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 80 Regulation of Fuels and Fuel Additives: Changes to Renewable Fuel Standard Program CFR Correction In Title 40 of the Code of Federal Regulations, Parts 72 to...-generating foreign producers and importers of renewable fuels for which RINs have been generated by the...

  6. Standards & Criteria for the Development and Evaluation of a Comprehensive Employee Assistance Program.

    Science.gov (United States)

    Health Resources and Services Administration, Rockville, MD. Bureau of Health Care Delivery and Assistance.

    This document was designed for use by persons or agencies interested in both establishing and evaluating employee assistance programs (EAP) for federal employees. It contains essential elements, standards, and assessment criteria which have been developed to assist in the planning and implementation of services, and to provide a framework for…

  7. Reliable quantification of bite-force performance requires use of appropriate biting substrate and standardization of bite out-lever.

    Science.gov (United States)

    Lappin, A Kristopher; Jones, Marc E H

    2014-12-15

    Bite-force performance is an ecologically important measure of whole-organism performance that shapes dietary breadth and feeding strategies and, in some taxa, determines reproductive success. It also is a metric that is crucial to testing and evaluating biomechanical models. We reviewed nearly 100 published studies of a range of taxa that incorporate direct in vivo measurements of bite force. Problematically, methods of data collection and processing vary considerably among studies. In particular, there is little consensus on the appropriate substrate to use on the biting surface of force transducers. In addition, the bite out-lever, defined as the distance from the fulcrum (i.e. jaw joint) to the position along the jawline at which the jaws engage the transducer, is rarely taken into account. We examined the effect of bite substrate and bite out-lever on bite-force estimates in a diverse sample of lizards. Results indicate that both variables have a significant impact on the accuracy of measurements. Maximum bite force is significantly greater using leather as the biting substrate compared with a metal substrate. Less-forceful bites on metal are likely due to inhibitory feedback from mechanoreceptors that prevent damage to the feeding apparatus. Standardization of bite out-lever affected which trial produced maximum performance for a given individual. Indeed, maximum bite force is usually underestimated without standardization because it is expected to be greatest at the minimum out-lever (i.e. back of the jaws), which in studies is rarely targeted with success. We assert that future studies should use a pliable substrate, such as leather, and use appropriate standardization for bite out-lever. © 2014. Published by The Company of Biologists Ltd.

  8. A Standardized "Rescue" Exercise Program for Symptomatic Flare-up of Knee Osteoarthritis

    DEFF Research Database (Denmark)

    Bartholdy, Cecilie; Klokker, Louise; Bandak, Elisabeth

    2016-01-01

    the implementation of standardized rescue exercises for patients with pain exacerbations and to assess whether performing these benefit or further worsen symptoms in patients with exacerbated symptoms of knee OA. Methods The data from 2 randomized controlled studies of exercise in patients with knee OA were used......Study Design Secondary analysis of clinical trial data. Background Knee osteoarthritis (OA) management has changed significantly over recent decades toward nonpharmacological treatments, particularly exercise. However, the optimal exercise program remains to be established. Objective To describe....... A supervised, standard exercise program that included standardized "rescue" exercises to be performed in the event of symptomatic exacerbation, defined as knee pain of greater than 5 on a 0-to-10 numeric pain-rating scale, was conducted for 12 weeks at 3 sessions per week. Pain ratings were obtained before...

  9. On the Reliability of Nonlinear Modeling using Enhanced Genetic Programming Techniques

    Science.gov (United States)

    Winkler, S. M.; Affenzeller, M.; Wagner, S.

    The use of genetic programming (GP) in nonlinear system identification enables the automated search for mathematical models that are evolved by an evolutionary process using the principles of selection, crossover and mutation. Due to the stochastic element that is intrinsic to any evolutionary process, GP cannot guarantee the generation of similar or even equal models in each GP process execution; still, if there is a physical model underlying to the data that are analyzed, then GP is expected to find these structures and produce somehow similar results. In this paper we define a function for measuring the syntactic similarity of mathematical models represented as structure trees; using this similarity function we compare the results produced by GP techniques for a data set representing measurement data of a BMW Diesel engine.

  10. Standard guide for establishing a quality assurance program for uranium conversion facilities

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide provides guidance and recommended practices for establishing a comprehensive quality assurance program for uranium conversion facilities. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate health and safety practices and determine the applicability of regulatory limitations prior to use. 1.3 The basic elements of a quality assurance program appear in the following order: FUNCTION SECTION Organization 5 Quality Assurance Program 6 Design Control 7 Instructions, Procedures & Drawings 8 Document Control 9 Procurement 10 Identification and Traceability 11 Processes 12 Inspection 13 Control of Measuring and Test Equipment 14 Handling, Storage and Shipping 15 Inspection, Test and Operating Status 16 Control of Nonconforming Items 17 Corrective Actions 18 Quality Assurance Records 19 Audits 20 TABLE 1 NQA-1 Basic Requirements Relat...

  11. Assessment of the Impacts of Standards and Labeling Programs inMexico (four products).

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Itha; Pulido, Henry; McNeil, Michael A.; Turiel, Isaac; della Cava, Mirka

    2007-06-12

    This study analyzes impacts from energy efficiency standards and labeling in Mexico from 1994 through 2005 for four major products: household refrigerators, room air conditioners, three-phase (squirrel cage) induction motors, and clothes washers. It is a retrospective analysis, seeking to assess verified impacts on product efficiency in the Mexican market in the first ten years after standards were implemented. Such an analysis allows the Mexican government to compare actual to originally forecast program benefits. In addition, it provides an extremely valuable benchmark for other countries considering standards, and to the energy policy community as a whole. The methodology for evaluation begins with historical test data taken for a large number of models of each product type between 1994 and 2005. The pre-standard efficiency of models in 1994 is taken as a baseline throughout the analysis. Model efficiency data were provided by an independent certification laboratory (ANCE), which tested products as part of the certification and enforcement mechanism defined by the standards program. Using this data, together with economic and market data provided by both government and private sector sources, the analysis considers several types of national level program impacts. These include: Energy savings; Environmental (emissions) impacts, and Net financial impacts to consumers, manufacturers and utilities. Energy savings impacts are calculated using the same methodology as the original projections, allowing a comparison. Other impacts are calculated using a robust and sophisticated methodology developed by the Instituto de Investigaciones Electricas (IIE) and Lawrence Berkeley National Laboratory (LBNL), in a collaboration supported by the Collaborative Labeling and Standards Program (CLASP).

  12. Evaluation of Public Service Electric & Gas Company`s standard offer program, Volume I

    Energy Technology Data Exchange (ETDEWEB)

    Goldman, C.A.; Kito, M.S.; Moezzi, M.M.

    1995-07-01

    In May 1993, Public Service Electric and Gas (PSE&G), the largest investor-owned utility in New Jersey, initiated the Standard Offer program, an innovative approach to acquiring demand-side management (DSM) resources. In this program, PSE&G offers longterm contracts with standard terms and conditions to project sponsors, either customers or third-party energy service companies (ESCOs), on a first-come, first-serve basis to fill a resource block. The design includes posted, time-differentiated prices which are paid for energy savings that will be verified over the contract term (5, 10, or 15 years) based on a statewide measurement and verification (M&V) protocol. The design of the Standard Offer differs significantly from DSM bidding programs in several respects. The eligibility requirements and posted prices allow ESCOs and other energy service providers to market and develop projects among customers with few constraints on acceptable end use efficiency technologies. In contrast, in DSM bidding, ESCOs typically submit bids without final commitments from customers and the utility selects a limited number of winning bidders who often agree to deliver a pre-specified mix of savings from various end uses in targeted markets. The major objectives of the LBNL evaluation were to assess market response and customer satisfaction; analyze program costs and cost-effectiveness; review and evaluate the utility`s administration and delivery of the program; examine the role of PSE&G`s energy services subsidiary (PSCRC) in the program and the effect of its involvement on the development of the energy services industry in New Jersey; and discuss the potential applicability of the Standard Offer concept given current trends in the electricity industry (i.e., increasing competition and the prospect of industry restructuring).

  13. Validation of a standard forensic anthropology examination protocol by measurement of applicability and reliability on exhumed and archive samples of known biological attribution.

    Science.gov (United States)

    Francisco, Raffaela Arrabaça; Evison, Martin Paul; Costa Junior, Moacyr Lobo da; Silveira, Teresa Cristina Pantozzi; Secchieri, José Marcelo; Guimarães, Marco Aurelio

    2017-10-01

    Forensic anthropology makes an important contribution to human identification and assessment of the causes and mechanisms of death and body disposal in criminal and civil investigations, including those related to atrocity, disaster and trafficking victim identification. The methods used are comparative, relying on assignment of questioned material to categories observed in standard reference material of known attribution. Reference collections typically originate in Europe and North America, and are not necessarily representative of contemporary global populations. Methods based on them must be validated when applied to novel populations. This study describes the validation of a standardized forensic anthropology examination protocol by application to two contemporary Brazilian skeletal samples of known attribution. One sample (n=90) was collected from exhumations following 7-35 years of burial and the second (n=30) was collected following successful investigations following routine case work. The study presents measurement of (1) the applicability of each of the methods: used and (2) the reliability with which the biographic parameters were assigned in each case. The results are discussed with reference to published assessments of methodological reliability regarding sex, age and-in particular-ancestry estimation. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Competence prized: program sets standards and maps out oilfield career paths for the first time

    International Nuclear Information System (INIS)

    Taylor, R.

    2000-01-01

    An ambitious program to address the problems of underqualified staff and staff shortages in the oil and gas industry was initiated in 1995 by the Petroleum Services Association of Canada. The intent of the program - the Petroleum Services Competency Program - was to create a labour force recognized as competent at what it does and to demonstrate to young people considering future careers that employment in the petroleum services sector could offer a rewarding career. The key strength of the PSCP is that assessment of an individual is on the job; competency assessment measures performance under working conditions with the reality, constraints, and pressures of the working environment. The program is modelled after the British National Vocational Qualification (NVQ) system. The certification database is maintained by the Petroleum Industry Training Service (PITS) which also issues the certification to successful graduates. PITS also provides training for assessors, although training for assessors is also provided by other training vendors. Auditors will monitor both assessor proficiency and equity of assessment between companies. To date certification standards for 28 occupations have been completed in the areas of pumping, wireline, trucking, well testing and well site supervision. In all cases competency standards are upgraded on a continuous basis to keep pace with advancing technology. Participation in the program is voluntary, and a certificate is not required for someone to work in the occupation. Nevertheless, official certification is the eventual goal. There is minimal government intervention. The program is strictly performance-based with no seniority or timeline used to determine worker competence; wages are not regulated or recommended through this program. The program is supported by a large number of oil companies, but like any change, it will take time to have a clear understanding of how the program benefits the entire oil and natural gas industry

  15. 24 CFR 200.949 - Building product standards and certification program for exterior insulated steel door systems.

    Science.gov (United States)

    2010-04-01

    ... INTRODUCTION TO FHA PROGRAMS Minimum Property Standards § 200.949 Building product standards and certification... product, the administrator's certification of compliance with the applicable standards is required to be... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Building product standards and...

  16. Renewables without limits : moving Ontario to advanced renewable tariffs by updating Ontario's groundbreaking standard offer program

    International Nuclear Information System (INIS)

    Gipe, P.

    2007-11-01

    The Ontario Sustainable Energy Association (OSEA) promotes the development of community-owned renewable energy generation. It was emphasized that in order to achieve OSEA's original objectives of developing as much renewable energy as quickly as possible through community participation, changes are needed to Ontario's groundbreaking standard offer contract (SOC) program. This report examined the status of Ontario's SOC program and proposed changes to the program as part of the program's first two-year review. The report provided a summary of the program and discussed each of the program's goals, notably to encourage broad participation; eliminate barriers to distributed renewable generation; provide a stable market for renewable generation; stimulate new investment in renewable generation; provide a rigorous pricing model for setting the tariffs; create a program applicable to all renewable technologies; provide a simple, streamlined, and cost-effective application process; and provide a dispute resolution process. The program goals as developed by the Ontario Power Authority and Ontario Energy Board were discussed with reference to mixed results to date; simplicity; removing barriers; balancing targets with value to ratepayers; and building on the efforts of OSEA. Advanced renewable tariffs (ART) and tariff determination was also discussed along with ART's in Germany, France, Spain and Ontario. Inflation indexing; tariff degression; proposed new tariffs by technology; and other costs and factors affecting profitability were also reviewed. ref., tabs

  17. A reliability simulation language for reliability analysis

    International Nuclear Information System (INIS)

    Deans, N.D.; Miller, A.J.; Mann, D.P.

    1986-01-01

    The results of work being undertaken to develop a Reliability Description Language (RDL) which will enable reliability analysts to describe complex reliability problems in a simple, clear and unambiguous way are described. Component and system features can be stated in a formal manner and subsequently used, along with control statements to form a structured program. The program can be compiled and executed on a general-purpose computer or special-purpose simulator. (DG)

  18. Data Availability in Appliance Standards and Labeling Program Development and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Romankiewicz, John [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Khanna, Nina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Vine, Edward [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Zhou, Nan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-05-01

    In this report, we describe the necessary data inputs for both standards development and program evaluation and perform an initial assessment of the availability and uncertainty of those data inputs in China. For standards development, we find that China and its standards and labeling program administrators currently has access to the basic market and technical data needed for conducting market and technology assessment and technological and economic analyses. Some data, such as shipments data, is readily available from the China Energy Label product registration database while the availability of other data, including average unit energy consumption, prices and design options, needs improvement. Unlike some other countries such as the United States, most of the necessary data for conducting standards development analyses are not publicly available or compiled in a consolidated data source. In addition, improved data on design and efficiency options as well as cost data (e.g., manufacturing costs, mark-ups, production and product use-phase costs) – key inputs to several technoeconomic analyses – are particularly in need given China’s unconsolidated manufacturing industry. For program evaluation, we find that while China can conduct simple savings evaluations on its incentive programs with the data it currently has available from the Ministry of Finance – the program administrator, the savings estimates produced by such an evaluation will carry high uncertainty. As such, China could benefit from an increase in surveying and metering in the next one to three years to decrease the uncertainty surrounding key data points such as unit energy savings and free ridership.

  19. Development of healthy eating and physical activity quality standards for out-of-school time programs.

    Science.gov (United States)

    Wiecha, Jean L; Hall, Georgia; Gannett, Ellen; Roth, Barbara

    2012-12-01

    Out-of-school time (OST) programs serve over 8 million children per year and have ample opportunity to promote health through menu and physical activity choices. Until recently, however, the field has lacked a comprehensive set of operationalizable standards for healthy eating and physical activity. The National AfterSchool Association adopted voluntary healthy eating and physical activity quality standards (HEPAQS) in April, 2011. We describe the development of HEPAQS. This work reflects a social ecological model for changing children's eating and activity behaviors through program-level interventions. The standards were developed using a national, mixed-methods needs assessment, review of existing standards and expert recommendations, and a participatory process of discussion, review, and consensus engaging 19 influential service and policy organizations and agencies in the Healthy Out-of-School Time (HOST) coalition, which we convened in 2009. The HOST coalition approved a final version of the HEPAQS in January, 2011. The 11 standards address content, curriculum selection, staff training, program support, and environmental support for healthy eating and physical activity. In April, 2011, the HEPAQS were adopted by the National AfterSchool Association, and have subsequently been widely disseminated. Extensive adoption and implementation efforts are underway. The availability of a comprehensive set of standards for healthy eating and physical activity in OST provides practical information to help community-based youth-serving organizations participate in obesity and chronic disease prevention. A working awareness of their content will be useful to scientists undertaking health promotion studies in the out-of-school time setting.

  20. NedWind 25 Blade Testing at NREL for the European Standards Measurement and Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Larwood, S.; Musial, W.; Freebury, G.; Beattie, A.G.

    2001-04-19

    In the mid-90s the European community initiated the Standards, Measurements, and Testing (SMT) program to harmonize testing and measurement procedures in several industries. Within the program, a project was carried out called the European Wind Turbine Testing Procedure Development. The second part of that project, called Blade Test Methods and Techniques, included the United States and was devised to help blade-testing laboratories harmonize their testing methods. This report provides the results of those tests conducted by the National Renewable Energy Laboratory.