WorldWideScience

Sample records for reliability assessment process

  1. Sequential optimization and reliability assessment method for metal forming processes

    International Nuclear Information System (INIS)

    Sahai, Atul; Schramm, Uwe; Buranathiti, Thaweepat; Chen Wei; Cao Jian; Xia, Cedric Z.

    2004-01-01

    Uncertainty is inevitable in any design process. The uncertainty could be due to the variations in geometry of the part, material properties or due to the lack of knowledge about the phenomena being modeled itself. Deterministic design optimization does not take uncertainty into account and worst case scenario assumptions lead to vastly over conservative design. Probabilistic design, such as reliability-based design and robust design, offers tools for making robust and reliable decisions under the presence of uncertainty in the design process. Probabilistic design optimization often involves double-loop procedure for optimization and iterative probabilistic assessment. This results in high computational demand. The high computational demand can be reduced by replacing computationally intensive simulation models with less costly surrogate models and by employing Sequential Optimization and reliability assessment (SORA) method. The SORA method uses a single-loop strategy with a series of cycles of deterministic optimization and reliability assessment. The deterministic optimization and reliability assessment is decoupled in each cycle. This leads to quick improvement of design from one cycle to other and increase in computational efficiency. This paper demonstrates the effectiveness of Sequential Optimization and Reliability Assessment (SORA) method when applied to designing a sheet metal flanging process. Surrogate models are used as less costly approximations to the computationally expensive Finite Element simulations

  2. Time-variant reliability assessment through equivalent stochastic process transformation

    International Nuclear Information System (INIS)

    Wang, Zequn; Chen, Wei

    2016-01-01

    Time-variant reliability measures the probability that an engineering system successfully performs intended functions over a certain period of time under various sources of uncertainty. In practice, it is computationally prohibitive to propagate uncertainty in time-variant reliability assessment based on expensive or complex numerical models. This paper presents an equivalent stochastic process transformation approach for cost-effective prediction of reliability deterioration over the life cycle of an engineering system. To reduce the high dimensionality, a time-independent reliability model is developed by translating random processes and time parameters into random parameters in order to equivalently cover all potential failures that may occur during the time interval of interest. With the time-independent reliability model, an instantaneous failure surface is attained by using a Kriging-based surrogate model to identify all potential failure events. To enhance the efficacy of failure surface identification, a maximum confidence enhancement method is utilized to update the Kriging model sequentially. Then, the time-variant reliability is approximated using Monte Carlo simulations of the Kriging model where system failures over a time interval are predicted by the instantaneous failure surface. The results of two case studies demonstrate that the proposed approach is able to accurately predict the time evolution of system reliability while requiring much less computational efforts compared with the existing analytical approach. - Highlights: • Developed a new approach for time-variant reliability analysis. • Proposed a novel stochastic process transformation procedure to reduce the dimensionality. • Employed Kriging models with confidence-based adaptive sampling scheme to enhance computational efficiency. • The approach is effective for handling random process in time-variant reliability analysis. • Two case studies are used to demonstrate the efficacy

  3. Evidential analytic hierarchy process dependence assessment methodology in human reliability analysis

    International Nuclear Information System (INIS)

    Chen, Lu Yuan; Zhou, Xinyi; Xiao, Fuyuan; Deng, Yong; Mahadevan, Sankaran

    2017-01-01

    In human reliability analysis, dependence assessment is an important issue in risky large complex systems, such as operation of a nuclear power plant. Many existing methods depend on an expert's judgment, which contributes to the subjectivity and restrictions of results. Recently, a computational method, based on the Dempster-Shafer evidence theory and analytic hierarchy process, has been proposed to handle the dependence in human reliability analysis. The model can deal with uncertainty in an analyst's judgment and reduce the subjectivity in the evaluation process. However, the computation is heavy and complicated to some degree. The most important issue is that the existing method is in a positive aspect, which may cause an underestimation of the risk. In this study, a new evidential analytic hierarchy process dependence assessment methodology, based on the improvement of existing methods, has been proposed, which is expected to be easier and more effective

  4. Evidential Analytic Hierarchy Process Dependence Assessment Methodology in Human Reliability Analysis

    Directory of Open Access Journals (Sweden)

    Luyuan Chen

    2017-02-01

    Full Text Available In human reliability analysis, dependence assessment is an important issue in risky large complex systems, such as operation of a nuclear power plant. Many existing methods depend on an expert's judgment, which contributes to the subjectivity and restrictions of results. Recently, a computational method, based on the Dempster–Shafer evidence theory and analytic hierarchy process, has been proposed to handle the dependence in human reliability analysis. The model can deal with uncertainty in an analyst's judgment and reduce the subjectivity in the evaluation process. However, the computation is heavy and complicated to some degree. The most important issue is that the existing method is in a positive aspect, which may cause an underestimation of the risk. In this study, a new evidential analytic hierarchy process dependence assessment methodology, based on the improvement of existing methods, has been proposed, which is expected to be easier and more effective.

  5. Evidential analytic hierarchy process dependence assessment methodology in human reliability analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Lu Yuan; Zhou, Xinyi; Xiao, Fuyuan; Deng, Yong [School of Computer and Information Science, Southwest University, Chongqing (China); Mahadevan, Sankaran [School of Engineering, Vanderbilt University, Nashville (United States)

    2017-02-15

    In human reliability analysis, dependence assessment is an important issue in risky large complex systems, such as operation of a nuclear power plant. Many existing methods depend on an expert's judgment, which contributes to the subjectivity and restrictions of results. Recently, a computational method, based on the Dempster-Shafer evidence theory and analytic hierarchy process, has been proposed to handle the dependence in human reliability analysis. The model can deal with uncertainty in an analyst's judgment and reduce the subjectivity in the evaluation process. However, the computation is heavy and complicated to some degree. The most important issue is that the existing method is in a positive aspect, which may cause an underestimation of the risk. In this study, a new evidential analytic hierarchy process dependence assessment methodology, based on the improvement of existing methods, has been proposed, which is expected to be easier and more effective.

  6. Harmonization process and reliability assessment of anthropometric measurements in the elderly EXERNET multi-centre study.

    Directory of Open Access Journals (Sweden)

    Alba Gómez-Cabello

    Full Text Available BACKGROUND: The elderly EXERNET multi-centre study aims to collect normative anthropometric data for old functionally independent adults living in Spain. PURPOSE: To describe the standardization process and reliability of the anthropometric measurements carried out in the pilot study and during the final workshop, examining both intra- and inter-rater errors for measurements. MATERIALS AND METHODS: A total of 98 elderly from five different regions participated in the intra-rater error assessment, and 10 different seniors living in the city of Toledo (Spain participated in the inter-rater assessment. We examined both intra- and inter-rater errors for heights and circumferences. RESULTS: For height, intra-rater technical errors of measurement (TEMs were smaller than 0.25 cm. For circumferences and knee height, TEMs were smaller than 1 cm, except for waist circumference in the city of Cáceres. Reliability for heights and circumferences was greater than 98% in all cases. Inter-rater TEMs were 0.61 cm for height, 0.75 cm for knee-height and ranged between 2.70 and 3.09 cm for the circumferences measured. Inter-rater reliabilities for anthropometric measurements were always higher than 90%. CONCLUSION: The harmonization process, including the workshop and pilot study, guarantee the quality of the anthropometric measurements in the elderly EXERNET multi-centre study. High reliability and low TEM may be expected when assessing anthropometry in elderly population.

  7. OSS reliability measurement and assessment

    CERN Document Server

    Yamada, Shigeru

    2016-01-01

    This book analyses quantitative open source software (OSS) reliability assessment and its applications, focusing on three major topic areas: the Fundamentals of OSS Quality/Reliability Measurement and Assessment; the Practical Applications of OSS Reliability Modelling; and Recent Developments in OSS Reliability Modelling. Offering an ideal reference guide for graduate students and researchers in reliability for open source software (OSS) and modelling, the book introduces several methods of reliability assessment for OSS including component-oriented reliability analysis based on analytic hierarchy process (AHP), analytic network process (ANP), and non-homogeneous Poisson process (NHPP) models, the stochastic differential equation models and hazard rate models. These measurement and management technologies are essential to producing and maintaining quality/reliable systems using OSS.

  8. Assessment of Sensory Processing and Executive Functions in Childhood: Development, Reliability, and Validity of the EPYFEI

    Directory of Open Access Journals (Sweden)

    Dulce Romero-Ayuso

    2018-03-01

    Full Text Available The aim of this study was to determine the psychometric properties of the “Assessment of Sensory Processing and Executive Functions in Childhood” (EPYFEI, a questionnaire designed to assess the sensory processing and executive functions of children aged between 3 and 11 years. The EPYFEI was completed by a sample of 1,732 parents of children aged between 3 and 11 years who lived in Spain. An exploratory factor analysis was conducted and showed five main factors: (1 executive attention, working memory, and initiation of actions; (2 general sensory processing; (3 emotional and behavioral self-regulation; (4 supervision, correction of actions, and problem solving; and (5 inhibitory. The reliability of the analysis was high both for the whole questionnaire and for the factors it is composed of. Results provide evidence of the potential usefulness of the EPYFEI in clinical contexts for the early detection of neurodevelopmental disorders, in which there may be a deficit of executive functions and sensory processing.

  9. Integration of human reliability analysis into the probabilistic risk assessment process: phase 1

    International Nuclear Information System (INIS)

    Bell, B.J.; Vickroy, S.C.

    1985-01-01

    The US Nuclear Regulatory Commission and Pacific Northwest Laboratory initiated a research program in 1984 to develop a testable set of analytical procedures for integrating human reliability analysis (HRA) into the probabilistic risk assessment (PRA) process to more adequately assess the overall impact of human performance on risk. In this three phase program, stand-alone HRA/PRA analytic procedures will be developed and field evaluated to provide improved methods, techniques, and models for applying quantitative and qualitative human error data which systematically integrate HRA principles, techniques, and analyses throughout the entire PRA process. Phase 1 of the program involved analysis of state-of-the-art PRAs to define the structures and processes currently in use in the industry. Phase 2 research will involve developing a new or revised PRA methodology which will enable more efficient regulation of the industry using quantitative or qualitative results of the PRA. Finally, Phase 3 will be to field test those procedures to assure that the results generated by the new methodologies will be usable and acceptable to the NRC. This paper briefly describes the first phase of the program and outlines the second

  10. Integration of human reliability analysis into the probabilistic risk assessment process: Phase 1

    International Nuclear Information System (INIS)

    Bell, B.J.; Vickroy, S.C.

    1984-10-01

    A research program was initiated to develop a testable set of analytical procedures for integrating human reliability analysis (HRA) into the probabilistic risk assessment (PRA) process to more adequately assess the overall impact of human performance on risk. In this three-phase program, stand-alone HRA/PRA analytic procedures will be developed and field evaluated to provide improved methods, techniques, and models for applying quantitative and qualitative human error data which systematically integrate HRA principles, techniques, and analyses throughout the entire PRA process. Phase 1 of the program involved analysis of state-of-the-art PRAs to define the structures and processes currently in use in the industry. Phase 2 research will involve developing a new or revised PRA methodology which will enable more efficient regulation of the industry using quantitative or qualitative results of the PRA. Finally, Phase 3 will be to field test those procedures to assure that the results generated by the new methodologies will be usable and acceptable to the NRC. This paper briefly describes the first phase of the program and outlines the second

  11. Approach to reliability assessment

    International Nuclear Information System (INIS)

    Green, A.E.; Bourne, A.J.

    1975-01-01

    Experience has shown that reliability assessments can play an important role in the early design and subsequent operation of technological systems where reliability is at a premium. The approaches to and techniques for such assessments, which have been outlined in the paper, have been successfully applied in variety of applications ranging from individual equipments to large and complex systems. The general approach involves the logical and systematic establishment of the purpose, performance requirements and reliability criteria of systems. This is followed by an appraisal of likely system achievment based on the understanding of different types of variational behavior. A fundamental reliability model emerges from the correlation between the appropriate Q and H functions for performance requirement and achievement. This model may cover the complete spectrum of performance behavior in all the system dimensions

  12. Dynamic analysis and reliability assessment of structures with uncertain-but-bounded parameters under stochastic process excitations

    International Nuclear Information System (INIS)

    Do, Duy Minh; Gao, Wei; Song, Chongmin; Tangaramvong, Sawekchai

    2014-01-01

    This paper presents the non-deterministic dynamic analysis and reliability assessment of structures with uncertain-but-bounded parameters under stochastic process excitations. Random ground acceleration from earthquake motion is adopted to illustrate the stochastic process force. The exact change ranges of natural frequencies, random vibration displacement and stress responses of structures are investigated under the interval analysis framework. Formulations for structural reliability are developed considering the safe boundary and structural random vibration responses as interval parameters. An improved particle swarm optimization algorithm, namely randomised lower sequence initialized high-order nonlinear particle swarm optimization algorithm, is employed to capture the better bounds of structural dynamic characteristics, random vibration responses and reliability. Three numerical examples are used to demonstrate the presented method for interval random vibration analysis and reliability assessment of structures. The accuracy of the results obtained by the presented method is verified by the randomised Quasi-Monte Carlo simulation method (QMCSM) and direct Monte Carlo simulation method (MCSM). - Highlights: • Interval uncertainty is introduced into structural random vibration responses. • Interval dynamic reliability assessments of structures are implemented. • Boundaries of structural dynamic response and reliability are achieved

  13. A comparative study of the probabilistic fracture mechanics and the stochastic Markovian process approaches for structural reliability assessment

    Energy Technology Data Exchange (ETDEWEB)

    Stavrakakis, G.; Lucia, A.C.; Solomos, G. (Commission of the European Communities, Ispra (Italy). Joint Research Centre)

    1990-01-01

    The two computer codes COVASTOL and RELIEF, developed for the modeling of cumulative damage processes in the framework of probabilistic structural reliability, are compared. They are based respectively on the randomisation of a differential crack growth law and on the theory of discrete Markov processes. The codes are applied for fatigue crack growth predictions using two sets of data of crack propagation curves from specimens. The results are critically analyzed and an extensive discussion follows on the merits and limitations of each code. Their transferability for the reliability assessment of real structures is investigated. (author).

  14. Safety and reliability assessment

    International Nuclear Information System (INIS)

    1979-01-01

    This report contains the papers delivered at the course on safety and reliability assessment held at the CSIR Conference Centre, Scientia, Pretoria. The following topics were discussed: safety standards; licensing; biological effects of radiation; what is a PWR; safety principles in the design of a nuclear reactor; radio-release analysis; quality assurance; the staffing, organisation and training for a nuclear power plant project; event trees, fault trees and probability; Automatic Protective Systems; sources of failure-rate data; interpretation of failure data; synthesis and reliability; quantification of human error in man-machine systems; dispersion of noxious substances through the atmosphere; criticality aspects of enrichment and recovery plants; and risk and hazard analysis. Extensive examples are given as well as case studies

  15. Assessing Reliability of Cellulose Hydrolysis Models to Support Biofuel Process Design – Identifiability and Uncertainty Analysis

    DEFF Research Database (Denmark)

    Sin, Gürkan; Meyer, Anne S.; Gernaey, Krist

    2010-01-01

    The reliability of cellulose hydrolysis models is studied using the NREL model. An identifiability analysis revealed that only 6 out of 26 parameters are identifiable from the available data (typical hydrolysis experiments). Attempting to identify a higher number of parameters (as done in the ori......The reliability of cellulose hydrolysis models is studied using the NREL model. An identifiability analysis revealed that only 6 out of 26 parameters are identifiable from the available data (typical hydrolysis experiments). Attempting to identify a higher number of parameters (as done...

  16. Operator reliability assessment system (OPERAS)

    International Nuclear Information System (INIS)

    Singh, A.; Spurgin, A.J.; Martin, T.; Welsch, J.; Hallam, J.W.

    1991-01-01

    OPERAS is a personal-computer (PC) based software to collect and process simulator data on control-room operators responses during requalification training scenarios. The data collection scheme is based upon approach developed earlier during the EPRI Operator Reliability Experiments project. The software allows automated data collection from simulator, thus minimizing simulator staff time and resources to collect, maintain and process data which can be useful in monitoring, assessing and enhancing the progress of crew reliability and effectiveness. The system is designed to provide the data and output information in the form of user-friendly charts, tables and figures for use by plant staff. OPERAS prototype software has been implemented at the Diablo Canyon (PWR) and Millstone (BWR) plants and is currently being used to collect operator response data. Data collected from similator include plant-state variables such as reactor pressure and temperature, malfunction, times at which annunciators are activated, operator actions and observations of crew behavior by training staff. The data and systematic analytical results provided by the OPERAS system can contribute to increase objectivity by the utility probabilistic risk analysis (PRA) and training staff in monitoring and assessing reliability of their crews

  17. Development of a Tablet-based symbol digit modalities test for reliably assessing information processing speed in patients with stroke.

    Science.gov (United States)

    Tung, Li-Chen; Yu, Wan-Hui; Lin, Gong-Hong; Yu, Tzu-Ying; Wu, Chien-Te; Tsai, Chia-Yin; Chou, Willy; Chen, Mei-Hsiang; Hsieh, Ching-Lin

    2016-09-01

    To develop a Tablet-based Symbol Digit Modalities Test (T-SDMT) and to examine the test-retest reliability and concurrent validity of the T-SDMT in patients with stroke. The study had two phases. In the first phase, six experts, nine college students and five outpatients participated in the development and testing of the T-SDMT. In the second phase, 52 outpatients were evaluated twice (2 weeks apart) with the T-SDMT and SDMT to examine the test-retest reliability and concurrent validity of the T-SDMT. The T-SDMT was developed via expert input and college student/patient feedback. Regarding test-retest reliability, the practise effects of the T-SDMT and SDMT were both trivial (d=0.12) but significant (p≦0.015). The improvement in the T-SDMT (4.7%) was smaller than that in the SDMT (5.6%). The minimal detectable changes (MDC%) of the T-SDMT and SDMT were 6.7 (22.8%) and 10.3 (32.8%), respectively. The T-SDMT and SDMT were highly correlated with each other at the two time points (Pearson's r=0.90-0.91). The T-SDMT demonstrated good concurrent validity with the SDMT. Because the T-SDMT had a smaller practise effect and less random measurement error (superior test-retest reliability), it is recommended over the SDMT for assessing information processing speed in patients with stroke. Implications for Rehabilitation The Symbol Digit Modalities Test (SDMT), a common measure of information processing speed, showed a substantial practise effect and considerable random measurement error in patients with stroke. The Tablet-based SDMT (T-SDMT) has been developed to reduce the practise effect and random measurement error of the SDMT in patients with stroke. The T-SDMT had smaller practise effect and random measurement error than the SDMT, which can provide more reliable assessments of information processing speed.

  18. Reliability Assessment Of Wind Turbines

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard

    2014-01-01

    Reduction of cost of energy for wind turbines are very important in order to make wind energy competitive compared to other energy sources. Therefore the turbine components should be designed to have sufficient reliability but also not be too costly (and safe). This paper presents models...... for uncertainty modeling and reliability assessment of especially the structural components such as tower, blades, substructure and foundation. But since the function of a wind turbine is highly dependent on many electrical and mechanical components as well as a control system also reliability aspects...... of these components are discussed and it is described how there reliability influences the reliability of the structural components. Two illustrative examples are presented considering uncertainty modeling, reliability assessment and calibration of partial safety factors for structural wind turbine components exposed...

  19. Software reliability assessment

    International Nuclear Information System (INIS)

    Barnes, M.; Bradley, P.A.; Brewer, M.A.

    1994-01-01

    The increased usage and sophistication of computers applied to real time safety-related systems in the United Kingdom has spurred on the desire to provide a standard framework within which to assess dependable computing systems. Recent accidents and ensuing legislation have acted as a catalyst in this area. One particular aspect of dependable computing systems is that of software, which is usually designed to reduce risk at the system level, but which can increase risk if it is unreliable. Various organizations have recognized the problem of assessing the risk imposed to the system by unreliable software, and have taken initial steps to develop and use such assessment frameworks. This paper relates the approach of Consultancy Services of AEA Technology in developing a framework to assess the risk imposed by unreliable software. In addition, the paper discusses the experiences gained by Consultancy Services in applying the assessment framework to commercial and research projects. The framework is applicable to software used in safety applications, including proprietary software. Although the paper is written with Nuclear Reactor Safety applications in mind, the principles discussed can be applied to safety applications in all industries

  20. New Approaches to Reliability Assessment

    DEFF Research Database (Denmark)

    Ma, Ke; Wang, Huai; Blaabjerg, Frede

    2016-01-01

    of energy. New approaches for reliability assessment are being taken in the design phase of power electronics systems based on the physics-of-failure in components. In this approach, many new methods, such as multidisciplinary simulation tools, strength testing of components, translation of mission profiles......, and statistical analysis, are involved to enable better prediction and design of reliability for products. This article gives an overview of the new design flow in the reliability engineering of power electronics from the system-level point of view and discusses some of the emerging needs for the technology...

  1. Reliability Assessment of Concrete Bridges

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle; Middleton, C. R.

    This paper is partly based on research performed for the Highways Agency, London, UK under the project DPU/9/44 "Revision of Bridge Assessment Rules Based on Whole Life Performance: concrete bridges". It contains the details of a methodology which can be used to generate Whole Life (WL) reliability...... profiles. These WL reliability profiles may be used to establish revised rules for concrete bridges. This paper is to some extend based on Thoft-Christensen et. al. [1996], Thoft-Christensen [1996] et. al. and Thoft-Christensen [1996]....

  2. Response process and test–retest reliability of the Context Assessment for Community Health tool in Vietnam

    Directory of Open Access Journals (Sweden)

    Duong M. Duc

    2016-06-01

    Full Text Available Background: The recently developed Context Assessment for Community Health (COACH tool aims to measure aspects of the local healthcare context perceived to influence knowledge translation in low- and middle-income countries. The tool measures eight dimensions (organizational resources , community engagement, monitoring services for action, sources of knowledge, commitment to work, work culture, leadership, and informal payment through 49 items. Objective: The study aimed to explore the understanding and stability of the COACH tool among health providers in Vietnam. Designs: To investigate the response process, think-aloud interviews were undertaken with five community health workers, six nurses and midwives, and five physicians. Identified problems were classified according to Conrad and Blair's taxonomy and grouped according to an estimation of the magnitude of the problem's effect on the response data. Further, the stability of the tool was examined using a test–retest survey among 77 respondents. The reliability was analyzed for items (intraclass correlation coefficient (ICC and percent agreement and dimensions (ICC and Bland–Altman plots. Results: In general, the think-aloud interviews revealed that the COACH tool was perceived as clear, well organized, and easy to answer. Most items were understood as intended. However, seven prominent problems in the items were identified and the content of three dimensions was perceived to be of a sensitive nature. In the test–retest survey, two-thirds of the items and seven of eight dimensions were found to have an ICC agreement ranging from moderate to substantial (0.5–0.7, demonstrating that the instrument has an acceptable level of stability. Conclusions: This study provides evidence that the Vietnamese translation of the COACH tool is generally perceived to be clear and easy to understand and has acceptable stability. There is, however, a need to rephrase and add generic examples to clarify

  3. Response process and test-retest reliability of the Context Assessment for Community Health tool in Vietnam.

    Science.gov (United States)

    Duc, Duong M; Bergström, Anna; Eriksson, Leif; Selling, Katarina; Thi Thu Ha, Bui; Wallin, Lars

    2016-01-01

    The recently developed Context Assessment for Community Health (COACH) tool aims to measure aspects of the local healthcare context perceived to influence knowledge translation in low- and middle-income countries. The tool measures eight dimensions (organizational resources, community engagement, monitoring services for action, sources of knowledge, commitment to work, work culture, leadership, and informal payment) through 49 items. The study aimed to explore the understanding and stability of the COACH tool among health providers in Vietnam. To investigate the response process, think-aloud interviews were undertaken with five community health workers, six nurses and midwives, and five physicians. Identified problems were classified according to Conrad and Blair's taxonomy and grouped according to an estimation of the magnitude of the problem's effect on the response data. Further, the stability of the tool was examined using a test-retest survey among 77 respondents. The reliability was analyzed for items (intraclass correlation coefficient (ICC) and percent agreement) and dimensions (ICC and Bland-Altman plots). In general, the think-aloud interviews revealed that the COACH tool was perceived as clear, well organized, and easy to answer. Most items were understood as intended. However, seven prominent problems in the items were identified and the content of three dimensions was perceived to be of a sensitive nature. In the test-retest survey, two-thirds of the items and seven of eight dimensions were found to have an ICC agreement ranging from moderate to substantial (0.5-0.7), demonstrating that the instrument has an acceptable level of stability. This study provides evidence that the Vietnamese translation of the COACH tool is generally perceived to be clear and easy to understand and has acceptable stability. There is, however, a need to rephrase and add generic examples to clarify some items and to further review items with low ICC.

  4. Reliability assessment of Wind turbines

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard

    2015-01-01

    Wind turbines can be considered as structures that are in between civil engineering structures and machines since they consist of structural components and many electrical and machine components together with a control system. Further, a wind turbine is not a one-of-a-kind structure...... but manufactured in series production based on many component tests, some prototype tests and zeroseries wind turbines. These characteristics influence the reliability assessment where focus in this paper is on the structural components. Levelized Cost Of Energy is very important for wind energy, especially when...... comparing to other energy sources. Therefore much focus is on cost reductions and improved reliability both for offshore and onshore wind turbines. The wind turbine components should be designed to have sufficient reliability level with respect to both extreme and fatigue loads but also not be too costly...

  5. Human reliability assessment and probabilistic risk assessment

    International Nuclear Information System (INIS)

    Embrey, D.E.; Lucas, D.A.

    1989-01-01

    Human reliability assessment (HRA) is used within Probabilistic Risk Assessment (PRA) to identify the human errors (both omission and commission) which have a significant effect on the overall safety of the system and to quantify the probability of their occurrence. There exist a variey of HRA techniques and the selection of an appropriate one is often difficult. This paper reviews a number of available HRA techniques and discusses their strengths and weaknesses. The techniques reviewed include: decompositional methods, time-reliability curves and systematic expert judgement techniques. (orig.)

  6. Assessing reliability in energy supply systems

    International Nuclear Information System (INIS)

    McCarthy, Ryan W.; Ogden, Joan M.; Sperling, Daniel

    2007-01-01

    Reliability has always been a concern in the energy sector, but concerns are escalating as energy demand increases and the political stability of many energy supply regions becomes more questionable. But how does one define and measure reliability? We introduce a method to assess reliability in energy supply systems in terms of adequacy and security. It derives from reliability assessment frameworks developed for the electricity sector, which are extended to include qualitative considerations and to be applicable to new energy systems by incorporating decision-making processes based on expert opinion and multi-attribute utility theory. The method presented here is flexible and can be applied to any energy system. To illustrate its use, we apply the method to two hydrogen pathways: (1) centralized steam reforming of imported liquefied natural gas with pipeline distribution of hydrogen, and (2) on-site electrolysis of water using renewable electricity produced independently from the electricity grid

  7. Interactive reliability assessment using an integrated reliability data bank

    International Nuclear Information System (INIS)

    Allan, R.N.; Whitehead, A.M.

    1986-01-01

    The logical structure, techniques and practical application of a computer-aided technique based on a microcomputer using floppy disc Random Access Files is described. This interactive computational technique is efficient if the reliability prediction program is coupled directly to a relevant source of data to create an integrated reliability assessment/reliability data bank system. (DG)

  8. Reliability data collection and use in risk and availability assessment

    International Nuclear Information System (INIS)

    Colombari, V.

    1989-01-01

    For EuReDatA it is a prevailing objective to initiate and support contact between experts, companies and institutions active in reliability engineering and research. Main topics of this 6th EuReDatA Conference are: Reliability data banks; incidents data banks; common cause data; source and propagation of uncertainties; computer aided risk analysis; reliability and incidents data acquisition and processing; human reliability; probabilistic safety and availability assessment; feedback of reliability into system design; data fusion; reliability modeling and techniques; structural and mechanical reliability; consequence modeling; software and electronic reliability; reliability tests. Some conference papers are separately indexed in the database. (HP)

  9. [Assessment of the validity and reliability of the processes of change scale based on the transtheoretical model of vegetable consumption behavior in Japanese male workers].

    Science.gov (United States)

    Kushida, Osamu; Murayama, Nobuko

    2012-12-01

    A core construct of the Transtheoretical model is that the processes and stages of change are strongly related to observable behavioral changes. We created the Processes of Change Scale of vegetable consumption behavior and examined the validity and reliability of this scale. In September 2009, a self-administered questionnaire was administered to male Japanese employees, aged 20-59 years, working at 20 worksites in Niigata City in Japan. The stages of change (precontempration, contemplation, preparation, action, and maintenance stage) were measured using 2 items that assessed participants' current implementation of the target behavior (eating 5 or more servings of vegetables per day) and their readiness to change their habits. The Processes of Change Scale of vegetable consumption behavior comprised 10 items assessing 5 cognitive processes (consciousness raising, emotional arousal, environmental reevaluation, self-reevaluation, and social liberation) and 5 behavioral processes (commitment, rewards, helping relationships, countering, and environment control). Each item was selected from an existing scale. Decisional balance (pros [2 items] and cons [2 items]), and self-efficacy (3 items) were also assessed, because these constructs were considered to be relevant to the processes of change. The internal consistency reliability of the scale was examined using Cronbach's alpha. Its construct validity was examined using a factor analysis of the processes of change, decisional balance, and self-efficacy variables, while its criterion-related validity was determined by assessing the association between the scale scores and the stages of change. The data of 527 (out of 600) participants (mean age, 41.1 years) were analyzed. Results indicated that the Processes of Change Scale had sufficient internal consistency reliability (Cronbach's alpha: cognitive processes=0.722, behavioral processes=0.803). The processes of change were divided into 2 factors: "consciousness raising

  10. Human reliability assessment in context

    International Nuclear Information System (INIS)

    Hollnagel, Erik

    2005-01-01

    Human Reliability Assessment (HRA) is conducted on the unspoken premise that 'human error' is a meaningful concept and that it can be associated with individual actions. The basis for this assumption it found in the origin of HRA, as a necessary extension of PSA to account for the impact of failures emanating from human actions. Although it was natural to model HRA on PSA, a large number of studies have shown that the premises are wrong, specifically that human and technological functions cannot be decomposed in the same manner. The general experience from accident studies also indicates that action failures are a function of the context, and that it is the variability of the context rather than the 'human error probability' that is the much sought for signal. Accepting this will have significant consequences for the way in which HRA, and ultimately also PSA, should be pursued

  11. Human reliability. Is probabilistic human reliability assessment possible?

    International Nuclear Information System (INIS)

    Mosneron Dupin, F.

    1996-01-01

    The possibility of carrying out Probabilistic Human Reliability Assessments (PHRA) is often doubted. Basing ourselves on the experience Electricite de France (EDF) has acquired in Probabilistic Safety Assessments for nuclear power plants, we show why the uncertainty of PHRA is very high. We then specify the limits of generic data and models for PHRA: very important factors are often poorly taken into account. To account for them, you need to have proper understanding of the actual context in which operators work. This demands surveys on the field (power plant and simulator) all of which must be carried out with behaviours science skills. The idea of estimating the probabilities of operator failure must not be abandoned, but probabilities must be given less importance, for they are only approximate indications. The qualitative aspects of PHRA should be given greater value (analysis process and qualitative insights). That is why the description (illustrated by case histories) of the main mechanisms of human behaviour, and of their manifestations in the nuclear power plant context (in terms of habits, attitudes, and informal methods and organization in particular) should be an important part of PHRA handbooks. These handbooks should also insist more on methods for gathering information on the actual context of the work of operators. Under these conditions, the PHRA should be possible and even desirable as a process for systematic analysis and assessment of human intervention. (author). 24 refs, 2 figs, 1 tab

  12. Human reliability. Is probabilistic human reliability assessment possible?

    Energy Technology Data Exchange (ETDEWEB)

    Mosneron Dupin, F

    1997-12-31

    The possibility of carrying out Probabilistic Human Reliability Assessments (PHRA) is often doubted. Basing ourselves on the experience Electricite de France (EDF) has acquired in Probabilistic Safety Assessments for nuclear power plants, we show why the uncertainty of PHRA is very high. We then specify the limits of generic data and models for PHRA: very important factors are often poorly taken into account. To account for them, you need to have proper understanding of the actual context in which operators work. This demands surveys on the field (power plant and simulator) all of which must be carried out with behaviours science skills. The idea of estimating the probabilities of operator failure must not be abandoned, but probabilities must be given less importance, for they are only approximate indications. The qualitative aspects of PHRA should be given greater value (analysis process and qualitative insights). That is why the description (illustrated by case histories) of the main mechanisms of human behaviour, and of their manifestations in the nuclear power plant context (in terms of habits, attitudes, and informal methods and organization in particular) should be an important part of PHRA handbooks. These handbooks should also insist more on methods for gathering information on the actual context of the work of operators. Under these conditions, the PHRA should be possible and even desirable as a process for systematic analysis and assessment of human intervention. (author). 24 refs, 2 figs, 1 tab.

  13. Automated reliability assessment for spectroscopic redshift measurements

    Science.gov (United States)

    Jamal, S.; Le Brun, V.; Le Fèvre, O.; Vibert, D.; Schmitt, A.; Surace, C.; Copin, Y.; Garilli, B.; Moresco, M.; Pozzetti, L.

    2018-03-01

    Context. Future large-scale surveys, such as the ESA Euclid mission, will produce a large set of galaxy redshifts (≥106) that will require fully automated data-processing pipelines to analyze the data, extract crucial information and ensure that all requirements are met. A fundamental element in these pipelines is to associate to each galaxy redshift measurement a quality, or reliability, estimate. Aim. In this work, we introduce a new approach to automate the spectroscopic redshift reliability assessment based on machine learning (ML) and characteristics of the redshift probability density function. Methods: We propose to rephrase the spectroscopic redshift estimation into a Bayesian framework, in order to incorporate all sources of information and uncertainties related to the redshift estimation process and produce a redshift posterior probability density function (PDF). To automate the assessment of a reliability flag, we exploit key features in the redshift posterior PDF and machine learning algorithms. Results: As a working example, public data from the VIMOS VLT Deep Survey is exploited to present and test this new methodology. We first tried to reproduce the existing reliability flags using supervised classification in order to describe different types of redshift PDFs, but due to the subjective definition of these flags (classification accuracy 58%), we soon opted for a new homogeneous partitioning of the data into distinct clusters via unsupervised classification. After assessing the accuracy of the new clusters via resubstitution and test predictions (classification accuracy 98%), we projected unlabeled data from preliminary mock simulations for the Euclid space mission into this mapping to predict their redshift reliability labels. Conclusions: Through the development of a methodology in which a system can build its own experience to assess the quality of a parameter, we are able to set a preliminary basis of an automated reliability assessment for

  14. Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR): Guide to data processing and revision: Part 2, Human error probability data entry and revision procedures

    International Nuclear Information System (INIS)

    Gilmore, W.E.; Gertman, D.I.; Gilbert, B.G.; Reece, W.J.

    1988-11-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automated data base management system for processing and storing human error probability (HEP) and hardware component failure data (HCFD). The NUCLARR system software resides on an IBM (or compatible) personal micro-computer. Users can perform data base searches to furnish HEP estimates and HCFD rates. In this manner, the NUCLARR system can be used to support a variety of risk assessment activities. This volume, Volume 3 of a 5-volume series, presents the procedures used to process HEP and HCFD for entry in NUCLARR and describes how to modify the existing NUCLARR taxonomy in order to add either equipment types or action verbs. Volume 3 also specifies the various roles of the administrative staff on assignment to the NUCLARR Clearinghouse who are tasked with maintaining the data base, dealing with user requests, and processing NUCLARR data. 5 refs., 34 figs., 3 tabs

  15. Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR): Guide to data processing and revision: Part 3, Hardware component failure data entry and revision procedures

    International Nuclear Information System (INIS)

    Gilmore, W.E.; Gertman, D.I.; Gilbert, B.G.; Reece, W.J.

    1988-11-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automated data base management system for processing and storing human error probability (HEP) and hardware component failure data (HCFD). The NUCLARR system software resides on an IBM (or compatible) personal micro-computer. Users can perform data base searches to furnish HEP estimates and HCFD rates. In this manner, the NUCLARR system can be used to support a variety of risk assessment activities. This volume, Volume 3 of a 5-volume series, presents the procedures used to process HEP and HCFD for entry in NUCLARR and describes how to modify the existing NUCLARR taxonomy in order to add equipment types of action verbs. Volume 3 also specifies the various roles of the administrative staff on assignment to the NUCLARR Clearinghouse who are tasked with maintaining the data base, dealing with user requests, and processing NUCLARR data

  16. Operational human performance reliability assessment (OHPRA)

    International Nuclear Information System (INIS)

    Haas, P.M.; Swanson, P.J.; Connelly, E.M.

    1993-01-01

    Operational Human Performance Reliability Assessment (OHPRA) is an approach for assessing human performance that is being developed in response to demands from modern process industries for practical and effective tools to assess and improve human performance, and therefore overall system performance and safety. The single most distinguishing feature of the approach is that is defines human performance in open-quotes operationalclose quotes terms. OHPRA is focused not on generation of human error probabilities, but on practical analysis of human performance to aid management in (1) identifying open-quotes fixableclose quotes problems and (2) providing input on the importance and nature of potential improvements. Development of the model in progress uses a unique approach for eliciting expert strategies for assessing performance. A PC-based model incorporating this expertise is planned. A preliminary version of the approach has already been used successfully to identify practical human performance problems in reactor and chemical process plant operations

  17. Equipment Reliability Process in Krsko NPP

    International Nuclear Information System (INIS)

    Gluhak, M.

    2016-01-01

    To ensure long-term safe and reliable plant operation, equipment operability and availability must also be ensured by setting a group of processes to be established within the nuclear power plant. Equipment reliability process represents the integration and coordination of important equipment reliability activities into one process, which enables equipment performance and condition monitoring, preventive maintenance activities development, implementation and optimization, continuous improvement of the processes and long term planning. The initiative for introducing systematic approach for equipment reliability assuring came from US nuclear industry guided by INPO (Institute of Nuclear Power Operations) and by participation of several US nuclear utilities. As a result of the initiative, first edition of INPO document AP-913, 'Equipment Reliability Process Description' was issued and it became a basic document for implementation of equipment reliability process for the whole nuclear industry. The scope of equipment reliability process in Krsko NPP consists of following programs: equipment criticality classification, preventive maintenance program, corrective action program, system health reports and long-term investment plan. By implementation, supervision and continuous improvement of those programs, guided by more than thirty years of operating experience, Krsko NPP will continue to be on a track of safe and reliable operation until the end of prolonged life time. (author).

  18. Structural reliability assessment capability in NESSUS

    Science.gov (United States)

    Millwater, H.; Wu, Y.-T.

    1992-07-01

    The principal capabilities of NESSUS (Numerical Evaluation of Stochastic Structures Under Stress), an advanced computer code developed for probabilistic structural response analysis, are reviewed, and its structural reliability assessed. The code combines flexible structural modeling tools with advanced probabilistic algorithms in order to compute probabilistic structural response and resistance, component reliability and risk, and system reliability and risk. An illustrative numerical example is presented.

  19. Reliability assessments in qualitative health promotion research.

    Science.gov (United States)

    Cook, Kay E

    2012-03-01

    This article contributes to the debate about the use of reliability assessments in qualitative research in general, and health promotion research in particular. In this article, I examine the use of reliability assessments in qualitative health promotion research in response to health promotion researchers' commonly held misconception that reliability assessments improve the rigor of qualitative research. All qualitative articles published in the journal Health Promotion International from 2003 to 2009 employing reliability assessments were examined. In total, 31.3% (20/64) articles employed some form of reliability assessment. The use of reliability assessments increased over the study period, ranging from qualitative articles decreased. The articles were then classified into four types of reliability assessments, including the verification of thematic codes, the use of inter-rater reliability statistics, congruence in team coding and congruence in coding across sites. The merits of each type were discussed, with the subsequent discussion focusing on the deductive nature of reliable thematic coding, the limited depth of immediately verifiable data and the usefulness of such studies to health promotion and the advancement of the qualitative paradigm.

  20. Human Reliability in Probabilistic Safety Assessments

    International Nuclear Information System (INIS)

    Nunez Mendez, J.

    1989-01-01

    Nowadays a growing interest in environmental aspects is detected in our country. It implies an assessment of the risk involved in the industrial processes and installations in order to determine if those are into the acceptable limits. In these safety assessments, among which PSA (Probabilistic Safety Assessments), can be pointed out the role played by the human being in the system is one of the more relevant subjects (This relevance has been demonstrated in the accidents happened) . However, in Spain there aren't manuals specifically dedicated to asses the human contribution to risk in the frame of PSAs. This report aims to improve this situation providing: a) a theoretical background to help the reader in the understanding of the nature of the human error, b) a quid to carry out a Human Reliability Analysis and c) a selected overview of the techniques and methodologies currently applied in this area. (Author) 20 refs

  1. Intraclass reliability for assessing how well Taiwan constrained hospital-provided medical services using statistical process control chart techniques.

    Science.gov (United States)

    Chien, Tsair-Wei; Chou, Ming-Ting; Wang, Wen-Chung; Tsai, Li-Shu; Lin, Weir-Sen

    2012-05-15

    Few studies discuss the indicators used to assess the effect on cost containment in healthcare across hospitals in a single-payer national healthcare system with constrained medical resources. We present the intraclass correlation coefficient (ICC) to assess how well Taiwan constrained hospital-provided medical services in such a system. A custom Excel-VBA routine to record the distances of standard deviations (SDs) from the central line (the mean over the previous 12 months) of a control chart was used to construct and scale annual medical expenditures sequentially from 2000 to 2009 for 421 hospitals in Taiwan to generate the ICC. The ICC was then used to evaluate Taiwan's year-based convergent power to remain unchanged in hospital-provided constrained medical services. A bubble chart of SDs for a specific month was generated to present the effects of using control charts in a national healthcare system. ICCs were generated for Taiwan's year-based convergent power to constrain its medical services from 2000 to 2009. All hospital groups showed a gradually well-controlled supply of services that decreased from 0.772 to 0.415. The bubble chart identified outlier hospitals that required investigation of possible excessive reimbursements in a specific time period. We recommend using the ICC to annually assess a nation's year-based convergent power to constrain medical services across hospitals. Using sequential control charts to regularly monitor hospital reimbursements is required to achieve financial control in a single-payer nationwide healthcare system.

  2. Operator reliability assessment system (OPERAS)

    International Nuclear Information System (INIS)

    Spurgin, A.J.; Hallam, J.W.; Spurgin, J.P.; Singh, A.

    1991-01-01

    The paper gives an overview of the OPERAS project. It discusses the background which led to the design of the PC-based data collection and analysis system connected to plant training simulators including those used for nuclear power plants. The usefulness of a system like OPERAS was perceived during an earlier EPRI project, the Operator Reliability Experiments project, by EPRI and PG and E. The data collection and analysis approaches used in OPERAS were developed during the ORE project. The paper not only discusses the design of OPERAS but discusses the functions performed and the current experiences with the two prototype systems. Also listed are potential uses of OPERAS by utility personnel in Operations, Training and PRA groups

  3. Improving Reliability of a Residency Interview Process

    Science.gov (United States)

    Serres, Michelle L.; Gundrum, Todd E.

    2013-01-01

    Objective. To improve the reliability and discrimination of a pharmacy resident interview evaluation form, and thereby improve the reliability of the interview process. Methods. In phase 1 of the study, authors used a Many-Facet Rasch Measurement model to optimize an existing evaluation form for reliability and discrimination. In phase 2, interviewer pairs used the modified evaluation form within 4 separate interview stations. In phase 3, 8 interviewers individually-evaluated each candidate in one-on-one interviews. Results. In phase 1, the evaluation form had a reliability of 0.98 with person separation of 6.56; reproducibly, the form separated applicants into 6 distinct groups. Using that form in phase 2 and 3, our largest variation source was candidates, while content specificity was the next largest variation source. The phase 2 g-coefficient was 0.787, while confirmatory phase 3 was 0.922. Process reliability improved with more stations despite fewer interviewers per station—impact of content specificity was greatly reduced with more interview stations. Conclusion. A more reliable, discriminating evaluation form was developed to evaluate candidates during resident interviews, and a process was designed that reduced the impact from content specificity. PMID:24159209

  4. Improving reliability of a residency interview process.

    Science.gov (United States)

    Peeters, Michael J; Serres, Michelle L; Gundrum, Todd E

    2013-10-14

    To improve the reliability and discrimination of a pharmacy resident interview evaluation form, and thereby improve the reliability of the interview process. In phase 1 of the study, authors used a Many-Facet Rasch Measurement model to optimize an existing evaluation form for reliability and discrimination. In phase 2, interviewer pairs used the modified evaluation form within 4 separate interview stations. In phase 3, 8 interviewers individually-evaluated each candidate in one-on-one interviews. In phase 1, the evaluation form had a reliability of 0.98 with person separation of 6.56; reproducibly, the form separated applicants into 6 distinct groups. Using that form in phase 2 and 3, our largest variation source was candidates, while content specificity was the next largest variation source. The phase 2 g-coefficient was 0.787, while confirmatory phase 3 was 0.922. Process reliability improved with more stations despite fewer interviewers per station-impact of content specificity was greatly reduced with more interview stations. A more reliable, discriminating evaluation form was developed to evaluate candidates during resident interviews, and a process was designed that reduced the impact from content specificity.

  5. Reevaluating Interrater Reliability in Offender Risk Assessment

    NARCIS (Netherlands)

    van der Knaap, L.M.; Leenarts, L.E.W.; Born, M.P.; Oosterveld, P.

    2012-01-01

    Offender risk and needs assessment, one of the pillars of the risk-need-responsivity model of offender rehabilitation, usually depends on raters assessing offender risk and needs. The few available studies of interrater reliability in offender risk assessment are, however, limited in the

  6. Reevaluating Interrater Reliability in Offender Risk Assessment

    Science.gov (United States)

    van der Knaap, Leontien M.; Leenarts, Laura E. W.; Born, Marise Ph.; Oosterveld, Paul

    2012-01-01

    Offender risk and needs assessment, one of the pillars of the risk-need-responsivity model of offender rehabilitation, usually depends on raters assessing offender risk and needs. The few available studies of interrater reliability in offender risk assessment are, however, limited in the generalizability of their results. The present study…

  7. Design and reliability of a didactic inphographic rubric assessment

    OpenAIRE

    Guzmán-cedillo, Yunuen Ixchel

    2017-01-01

    The objective of this study is to describe design, validity process and reliability of a rubric assessment to evaluate didactic infographics quality. Participants were fifteen judges who participate in different moments of elaboration rubric process; it was made in three process phases: design, settings and reliability determination. Content validity was obtained by percentage agreement between 3 judges by component of the rubric; likewise a Krippendorff’s alpha were applied (a = .710) in pi...

  8. A general software reliability process simulation technique

    Science.gov (United States)

    Tausworthe, Robert C.

    1991-01-01

    The structure and rationale of the generalized software reliability process, together with the design and implementation of a computer program that simulates this process are described. Given assumed parameters of a particular project, the users of this program are able to generate simulated status timelines of work products, numbers of injected anomalies, and the progress of testing, fault isolation, repair, validation, and retest. Such timelines are useful in comparison with actual timeline data, for validating the project input parameters, and for providing data for researchers in reliability prediction modeling.

  9. An approach for assessing human decision reliability

    International Nuclear Information System (INIS)

    Pyy, P.

    2000-01-01

    This paper presents a method to study human reliability in decision situations related to nuclear power plant disturbances. Decisions often play a significant role in handling of emergency situations. The method may be applied to probabilistic safety assessments (PSAs) in cases where decision making is an important dimension of an accident sequence. Such situations are frequent e.g. in accident management. In this paper, a modelling approach for decision reliability studies is first proposed. Then, a case study with two decision situations with relatively different characteristics is presented. Qualitative and quantitative findings of the study are discussed. In very simple decision cases with time pressure, time reliability correlation proved out to be a feasible reliability modelling method. In all other decision situations, more advanced probabilistic decision models have to be used. Finally, decision probability assessment by using simulator run results and expert judgement is presented

  10. Reliability assessment based on subjective inferences

    International Nuclear Information System (INIS)

    Ma Zhibo; Zhu Jianshi; Xu Naixin

    2003-01-01

    The reliability information which comes from subjective analysis is often incomplete prior. This information can be generally assumed to exist in the form of either a stated prior mean of R (reliability) or a stated prior credibility interval on R. An efficient approach is developed to determine a complete beta prior distribution from the subjective information according to the principle of maximum entropy, and the the reliability of survival/failure product is assessed via Bayes theorem. Numerical examples are presented to illustrate the methods

  11. Reliable processing of graphene using metal etchmasks

    Directory of Open Access Journals (Sweden)

    Peltekis Nikos

    2011-01-01

    Full Text Available Abstract Graphene exhibits exciting properties which make it an appealing candidate for use in electronic devices. Reliable processes for device fabrication are crucial prerequisites for this. We developed a large area of CVD synthesis and transfer of graphene films. With patterning of these graphene layers using standard photoresist masks, we are able to produce arrays of gated graphene devices with four point contacts. The etching and lift off process poses problems because of delamination and contamination due to polymer residues when using standard resists. We introduce a metal etch mask which minimises these problems. The high quality of graphene is shown by Raman and XPS spectroscopy as well as electrical measurements. The process is of high value for applications, as it improves the processability of graphene using high-throughput lithography and etching techniques.

  12. Assessment of the Reliability of Concrete Bridges

    DEFF Research Database (Denmark)

    Middleton, C. R.; Thoft-Christensen, Palle

    Although there has been a considerable amount of research into different aspects of concrete bridge reliability, it has still not been widely adopted in professional practice other than in the development and calibration of codes. This situation appears to be changing as there has been a signific......Although there has been a considerable amount of research into different aspects of concrete bridge reliability, it has still not been widely adopted in professional practice other than in the development and calibration of codes. This situation appears to be changing as there has been...... adopted to assist in achieving this goal. Rather than review the specific research on this subject this paper examines a number of key issues related to the practical application of reliability analysis to the assessment of concrete bridges....

  13. Product reliability and the reliability of its emanating operational processes.

    NARCIS (Netherlands)

    Sonnemans, P.J.M.; Geudens, W.H.J.M.

    1999-01-01

    This paper addresses the problem of proper reliability management in business operations today, facing increasing demands on essential business drivers such as time to market, quality and financial profit. In this paper a general method is described of how to achieve product quality in a highly

  14. Reliability analysis and assessment of structural systems

    International Nuclear Information System (INIS)

    Yao, J.T.P.; Anderson, C.A.

    1977-01-01

    The study of structural reliability deals with the probability of having satisfactory performance of the structure under consideration within any specific time period. To pursue this study, it is necessary to apply available knowledge and methodology in structural analysis (including dynamics) and design, behavior of materials and structures, experimental mechanics, and the theory of probability and statistics. In addition, various severe loading phenomena such as strong motion earthquakes and wind storms are important considerations. For three decades now, much work has been done on reliability analysis of structures, and during this past decade, certain so-called 'Level I' reliability-based design codes have been proposed and are in various stages of implementation. These contributions will be critically reviewed and summarized in this paper. Because of the undesirable consequences resulting from the failure of nuclear structures, it is important and desirable to consider the structural reliability in the analysis and design of these structures. Moreover, after these nuclear structures are constructed, it is desirable for engineers to be able to assess the structural reliability periodically as well as immediately following the occurrence of severe loading conditions such as a strong-motion earthquake. During this past decade, increasing use has been made of techniques of system identification in structural engineering. On the basis of non-destructive test results, various methods have been developed to obtain an adequate mathematical model (such as the equations of motion with more realistic parameters) to represent the structural system

  15. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  16. Reliability and Probabilistic Risk Assessment - How They Play Together

    Science.gov (United States)

    Safie, Fayssal M.; Stutts, Richard G.; Zhaofeng, Huang

    2015-01-01

    PRA methodology is one of the probabilistic analysis methods that NASA brought from the nuclear industry to assess the risk of LOM, LOV and LOC for launch vehicles. PRA is a system scenario based risk assessment that uses a combination of fault trees, event trees, event sequence diagrams, and probability and statistical data to analyze the risk of a system, a process, or an activity. It is a process designed to answer three basic questions: What can go wrong? How likely is it? What is the severity of the degradation? Since 1986, NASA, along with industry partners, has conducted a number of PRA studies to predict the overall launch vehicles risks. Planning Research Corporation conducted the first of these studies in 1988. In 1995, Science Applications International Corporation (SAIC) conducted a comprehensive PRA study. In July 1996, NASA conducted a two-year study (October 1996 - September 1998) to develop a model that provided the overall Space Shuttle risk and estimates of risk changes due to proposed Space Shuttle upgrades. After the Columbia accident, NASA conducted a PRA on the Shuttle External Tank (ET) foam. This study was the most focused and extensive risk assessment that NASA has conducted in recent years. It used a dynamic, physics-based, integrated system analysis approach to understand the integrated system risk due to ET foam loss in flight. Most recently, a PRA for Ares I launch vehicle has been performed in support of the Constellation program. Reliability, on the other hand, addresses the loss of functions. In a broader sense, reliability engineering is a discipline that involves the application of engineering principles to the design and processing of products, both hardware and software, for meeting product reliability requirements or goals. It is a very broad design-support discipline. It has important interfaces with many other engineering disciplines. Reliability as a figure of merit (i.e. the metric) is the probability that an item will

  17. DUAL-PROCESS, a highly reliable process control system

    International Nuclear Information System (INIS)

    Buerger, L.; Gossanyi, A.; Parkanyi, T.; Szabo, G.; Vegh, E.

    1983-02-01

    A multiprocessor process control system is described. During its development the reliability was the most important aspect because it is used in the computerized control of a 5 MW research reactor. DUAL-PROCESS is fully compatible with the earlier single processor control system PROCESS-24K. The paper deals in detail with the communication, synchronization, error detection and error recovery problems of the operating system. (author)

  18. Methodology for reliability based condition assessment

    International Nuclear Information System (INIS)

    Mori, Y.; Ellingwood, B.

    1993-08-01

    Structures in nuclear power plants may be exposed to aggressive environmental effects that cause their strength to decrease over an extended period of service. A major concern in evaluating the continued service for such structures is to ensure that in their current condition they are able to withstand future extreme load events during the intended service life with a level of reliability sufficient for public safety. This report describes a methodology to facilitate quantitative assessments of current and future structural reliability and performance of structures in nuclear power plants. This methodology takes into account the nature of past and future loads, and randomness in strength and in degradation resulting from environmental factors. An adaptive Monte Carlo simulation procedure is used to evaluate time-dependent system reliability. The time-dependent reliability is sensitive to the time-varying load characteristics and to the choice of initial strength and strength degradation models but not to correlation in component strengths within a system. Inspection/maintenance strategies are identified that minimize the expected future costs of keeping the failure probability of a structure at or below an established target failure probability during its anticipated service period

  19. Reliability assessment of nuclear structural systems

    International Nuclear Information System (INIS)

    Reich, M.; Hwang, H.

    1983-01-01

    Reliability assessment of nuclear structural systems has been receiving more emphasis over the last few years. This paper deals with the recent progress made by the Structural Analysis Division of Brookhaven National Laboratory (BNL), in the development of a probability-based reliability analysis methodology for safety evaluation of reactor containments and other seismic category I structures. An important feature of this methodology is the incorporation of finite element analysis and random vibration theory. By utilizing this method, it is possible to evaluate the safety of nuclear structures under various static and dynamic loads in terms of limit state probability. Progress in other related areas, such as the establishment of probabilistic characteristics for various loads and structural resistance, are also described. Results of an application of the methodology to a realistic reinforced concrete containment subjected to dead and live loads, accidental internal pressures and earthquake ground accelerations are presented

  20. Sequential decision reliability concept and failure rate assessment

    International Nuclear Information System (INIS)

    Ciftcioglu, O.

    1990-11-01

    Conventionally, a reliability concept is considered together with both each basic unit and their integration in a complicated large scale system such as a nuclear power plant (NPP). Basically, as the plant's operational status is determined by the information obtained from various sensors, the plant's reliability and the risk assessment is closely related to the reliability of the sensory information and hence the sensor components. However, considering the relevant information-processing systems, e.g. fault detection processors, there exists a further question about the reliability of such systems, specifically the reliability of the systems' decision-based outcomes by means of which the further actions are performed. To this end, a general sequential decision reliability concept and the failure rate assessment methodology is introduced. The implications of the methodology are investigated and the importance of the decision reliability concept in system operation is demonstrated by means of sensory signals in real-time from the Borssele NPP in the Netherlands. (author). 21 refs.; 8 figs

  1. Structural reliability analysis and seismic risk assessment

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Shinozuka, M.

    1984-01-01

    This paper presents a reliability analysis method for safety evaluation of nuclear structures. By utilizing this method, it is possible to estimate the limit state probability in the lifetime of structures and to generate analytically the fragility curves for PRA studies. The earthquake ground acceleration, in this approach, is represented by a segment of stationary Gaussian process with a zero mean and a Kanai-Tajimi Spectrum. All possible seismic hazard at a site represented by a hazard curve is also taken into consideration. Furthermore, the limit state of a structure is analytically defined and the corresponding limit state surface is then established. Finally, the fragility curve is generated and the limit state probability is evaluated. In this paper, using a realistic reinforced concrete containment as an example, results of the reliability analysis of the containment subjected to dead load, live load and ground earthquake acceleration are presented and a fragility curve for PRA studies is also constructed

  2. Human reliability in probabilistic safety assessments

    International Nuclear Information System (INIS)

    Nunez Mendez, J.

    1989-01-01

    Nowadays a growing interest in medioambiental aspects is detected in our country. It implies an assessment of the risk involved in the industrial processess and installations in order to determine if those are into the acceptable limits. In these safety assessments, among which PSA (Probabilistic Safety Assessments), can be pointed out the role played by the human being in the system is one of the more relevant subjects. (This relevance has been demostrated in the accidents happenned). However in Spain there aren't manuals specifically dedicated to asses the human contribution to risk in the frame of PSAs. This report aims to improve this situation providing: a) a theoretical background to help the reader in the understanding of the nature of the human error, b) a guide to carry out a Human Reliability Analysis and c) a selected overwiev of the techniques and methodologies currently applied in this area. (Author)

  3. Student Precision and Reliability of the Team Sport Assessment in ...

    African Journals Online (AJOL)

    TSAP) and formative assessment of invasion sport. The specific objectives were to determine the degree of agreement among expert observers, inter-observer reliability (internal consistency), and intra observer reliability (temporal reliability).

  4. Reliability of histologic assessment in patients with eosinophilic oesophagitis.

    Science.gov (United States)

    Warners, M J; Ambarus, C A; Bredenoord, A J; Verheij, J; Lauwers, G Y; Walsh, J C; Katzka, D A; Nelson, S; van Viegen, T; Furuta, G T; Gupta, S K; Stitt, L; Zou, G; Parker, C E; Shackelton, L M; D Haens, G R; Sandborn, W J; Dellon, E S; Feagan, B G; Collins, M H; Jairath, V; Pai, R K

    2018-04-01

    The validity of the eosinophilic oesophagitis (EoE) histologic scoring system (EoEHSS) has been demonstrated, but only preliminary reliability data exist. Formally assess the reliability of the EoEHSS and additional histologic features. Four expert gastrointestinal pathologists independently reviewed slides from adult patients with EoE (N = 45) twice, in random order, using standardised training materials and scoring conventions for the EoEHSS and additional histologic features agreed upon during a modified Delphi process. Intra- and inter-rater reliability for scoring the EoEHSS, a visual analogue scale (VAS) of overall histopathologic disease severity, and additional histologic features were assessed using intra-class correlation coefficients (ICCs). Almost perfect intra-rater reliability was observed for the composite EoEHSS scores and the VAS. Inter-rater reliability was also almost perfect for the composite EoEHSS scores and substantial for the VAS. Of the EoEHSS items, eosinophilic inflammation was associated with the highest ICC estimates and consistent with almost perfect intra- and inter-rater reliability. With the exception of dyskeratotic epithelial cells and surface epithelial alteration, ICC estimates for the remaining EoEHSS items were above the benchmarks for substantial intra-rater, and moderate inter-rater reliability. Estimation of peak eosinophil count and number of lamina propria eosinophils were associated with the highest ICC estimates among the exploratory items. The composite EoEHSS and most component items are associated with substantial reliability when assessed by central pathologists. Future studies should assess responsiveness of the score to change after a therapeutic intervention to facilitate its use in clinical trials. © 2018 John Wiley & Sons Ltd.

  5. The analytic hierarchy process as a systematic approach to the identification of important parameters for the reliability assessment of passive systems

    International Nuclear Information System (INIS)

    Zio, E.; Cantarella, M.; Cammi, A.

    2003-01-01

    Passive systems play a crucial role in the development of future solutions for nuclear plant technology. A fundamental issue still to be resolved is the quantification of the reliability of such systems. In this paper, we firstly illustrate a systematic methodology to guide the definition of the failure criteria of a passive system and the evaluation of its probability of occurrence, through the identification of the relevant system parameters and the propagation of their associated uncertainties. Within this methodology, we propose the use of the analytic hierarchy process as a structured and reproducible tool for the decomposition of the problem and the identification of the dominant system parameters. An example of its application to a real passive system is illustrated in details

  6. Assessment of physical server reliability in multi cloud computing system

    Science.gov (United States)

    Kalyani, B. J. D.; Rao, Kolasani Ramchand H.

    2018-04-01

    Business organizations nowadays functioning with more than one cloud provider. By spreading cloud deployment across multiple service providers, it creates space for competitive prices that minimize the burden on enterprises spending budget. To assess the software reliability of multi cloud application layered software reliability assessment paradigm is considered with three levels of abstractions application layer, virtualization layer, and server layer. The reliability of each layer is assessed separately and is combined to get the reliability of multi-cloud computing application. In this paper, we focused on how to assess the reliability of server layer with required algorithms and explore the steps in the assessment of server reliability.

  7. Reliability of medical audit in quality assessment of medical care

    Directory of Open Access Journals (Sweden)

    Camacho Luiz Antonio Bastos

    1996-01-01

    Full Text Available Medical audit of hospital records has been a major component of quality of care assessment, although physician judgment is known to have low reliability. We estimated interrater agreement of quality assessment in a sample of patients with cardiac conditions admitted to an American teaching hospital. Physician-reviewers used structured review methods designed to improve quality assessment based on judgment. Chance-corrected agreement for the items considered more relevant to process and outcome of care ranged from low to moderate (0.2 to 0.6, depending on the review item and the principal diagnoses and procedures the patients underwent. Results from several studies seem to converge on this point. Comparisons among different settings should be made with caution, given the sensitivity of agreement measurements to prevalence rates. Reliability of review methods in their current stage could be improved by combining the assessment of two or more reviewers, and by emphasizing outcome-oriented events.

  8. The DYLAM approach to systems safety and reliability assessment

    International Nuclear Information System (INIS)

    Amendola, A.

    1988-01-01

    A survey of the principal features and applications of DYLAM (Dynamic Logical Analytical Methodology) is presented, whose basic principles can be summarized as follows: after a particular modelling of the component states, computerized heuristical procedures generate stochastic configurations of the system, whereas the resulting physical processes are simultaneously simulated to give account of the possible interactions between physics and states and, on the other hand, to search for system dangerous configurations and related probabilities. The association of probabilistic techniques for describing the states with physical equations for describing the process results in a very powerful tool for safety and reliability assessment of systems potentially subjected to dangerous incidental transients. A comprehensive picture of DYLAM capability for manifold applications can be obtained by the review of the study cases analyzed (LMFBR core accident, systems reliability assessment, accident simulation, man-machine interaction analysis, chemical reactors safety, etc.)

  9. Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR): Data manual

    International Nuclear Information System (INIS)

    Gilbert, B.G.; Reece, W.J.; Gertman, D.I.; Gilmore, W.E.; Galyean, W.J.

    1990-12-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automated data base management system for processing and storing human error probability and hardware component failure data. The NUCLARR system software resides on an IBM (or compatible) personal computer. NUCLARR can furnish the end user with data inputs for both human and hardware reliability analysis in support of a variety of risk assessment activities. The NUCLARR system is documented is a five-volume series of reports. Volume V: Data Manual provides a hard-copy representation of all data and related information available within the NUCLARR system software. This document is organized in three sections. Part 1 is the summary description, which presents an overview of the NUCLARR system and data processing procedures. Part 2 contains all data and information relevant to the human error probability (HEP) data side of NUCLARR. Data and information for the hardware component failure data (HCFD) side are presented in Part 3. 7 refs

  10. Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR)

    International Nuclear Information System (INIS)

    Gilbert, B.G.; Reece, W.J.; Gertman, D.I.; Gilmore, W.E.; Galyean, W.J.

    1990-12-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automated data base management system for processing and storing human error probability and hardware component failure data. The NUCLARR system software resides on an IBM (or compatible) personal computer. NUCLARR can furnish the end user with data inputs for both human and hardware reliability analysis in support of a variety of risk assessment activities. The NUCLARR system is documented in a five-volume series of reports. Volume 5: Data Manual provides a hard-copy representation of all data and related information available within the NUCLARR system software. This document is organized in three sections. Part 1 is the summary description, which presents an overview of the NUCLARR system and data processing procedures. Part 2 contains all data and information relevant to the human error probability (HEP) data side of NUCLARR. Data and information for the hardware component failure data (HCFD) side are presented in Part 3. 7 refs

  11. Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR): Data manual

    International Nuclear Information System (INIS)

    Gilbert, B.G.; Reece, W.J.; Gertman, D.I.; Gilmore, W.E.; Galyean, W.J.

    1990-12-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automated data base management system for processing and storing human error probability and hardware component failure data. The NUCLARR system software resides on an IBM (or compatible) personal computer. NUCLARR can furnish the end user with data inputs for both human and hardware reliability analysis in support of a variety of risk assessment activities. The NUCLARR system is documented in a five-volume series of reports. Volume V: Data Manual provides a hard-copy representation of all data and related information available within the NUCLARR system software. This document is organized in three sections. Part 1 is the summary description, which presents an overview of the NUCLARR system and data processing procedures. Part 2 contains all data and information relevant to the human error probability (HEP) side of NUCLARR. Data and information for the hardware component failure data (HCFD) side are presented in Part 3. 7 refs., 1 fig

  12. Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR): Summary description

    International Nuclear Information System (INIS)

    Gertman, D.I.; Gilmore, W.E.; Galyean, W.J.; Groh, M.R.; Gentillon, C.D.; Gilbert, B.G.; Reece, W.J.

    1990-05-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automate data base management system for storing and processing human error probability and hardware component failure rate data. The NUCLARR system software resides on an IBM (or compatible) personal microcomputer. NUCLARR can be accessed by the end user to furnish data suitable for input in human and/or hardware reliability analysis to support a variety of risk assessment activities. The NUCLARR system is documented in a five-volume series of reports. This document Volume 1, of this series is the Summary Description, which presents an overview of the data management system, including a description of data collection, data qualification, data structure, and taxonomies. Programming activities, procedures for processing data, a user's guide, and hard copy data manual are presented in Volumes 2 through 5, NUREG/CR-4639

  13. Lifetime Reliability Assessment of Concrete Slab Bridges

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    A procedure for lifetime assesment of the reliability of short concrete slab bridges is presented in the paper. Corrosion of the reinforcement is the deterioration mechanism used for estimating the reliability profiles for such bridges. The importance of using sensitivity measures is stressed....... Finally the produce is illustrated on 6 existing UK bridges....

  14. Reliability assessment using Bayesian networks. Case study on quantative reliability estimation of a software-based motor protection relay

    International Nuclear Information System (INIS)

    Helminen, A.; Pulkkinen, U.

    2003-06-01

    In this report a quantitative reliability assessment of motor protection relay SPAM 150 C has been carried out. The assessment focuses to the methodological analysis of the quantitative reliability assessment using the software-based motor protection relay as a case study. The assessment method is based on Bayesian networks and tries to take the full advantage of the previous work done in a project called Programmable Automation System Safety Integrity assessment (PASSI). From the results and experiences achieved during the work it is justified to claim that the assessment method presented in the work enables a flexible use of qualitative and quantitative elements of reliability related evidence in a single reliability assessment. At the same time the assessment method is a concurrent way of reasoning one's beliefs and references about the reliability of the system. Full advantage of the assessment method is taken when using the method as a way to cultivate the information related to the reliability of software-based systems. The method can also be used as a communicational instrument in a licensing process of software-based systems. (orig.)

  15. Design and reliability of a didactic inphographic rubric assessment

    Directory of Open Access Journals (Sweden)

    Yunuen Ixchel GUZMÁN-CEDILLO

    2017-12-01

    Full Text Available The objective of this study is to describe design, validity process and reliability of a rubric assessment to evaluate didactic infographics quality. Participants were fifteen judges who participate in different moments of elaboration rubric process; it was made in three process phases: design, settings and reliability determination. Content validity was obtained by percentage agreement between 3 judges by component of the rubric; likewise a Krippendorff’s alpha were applied (a = .710 in pilot assessment with 5 infographics in order to set possible writings contradictions between components and criteria of performance. The intern consistence was determined by Cronbach’s alpha (? = .806 in 22 infographics gradation. An Intraclass correlation coefficient icc (a = .909 was applied to 6 judges qualifications also a Krippendorff’s alpha (a = .538 both of them in ordinal levels. The rubric is composed by 9 components, 3 performance levels, definitions of each component and assignments how to use the rubric. Results suggest the rubric is valid and reliable to grade quality of didactic infographic.

  16. An approach for assessing ALWR passive safety system reliability

    International Nuclear Information System (INIS)

    Hake, T.M.

    1991-01-01

    Many advanced light water reactor designs incorporate passive rather than active safety features for front-line accident response. A method for evaluating the reliability of these passive systems in the context of probabilistic risk assessment has been developed at Sandia National Laboratories. This method addresses both the component (e.g. valve) failure aspect of passive system failure, and uncertainties in system success criteria arising from uncertainties in the system's underlying physical processes. These processes provide the system's driving force; examples are natural circulation and gravity-induced injection. This paper describes the method, and provides some preliminary results of application of the approach to the Westinghouse AP600 design

  17. Computer-aided reliability and risk assessment

    International Nuclear Information System (INIS)

    Leicht, R.; Wingender, H.J.

    1989-01-01

    Activities in the fields of reliability and risk analyses have led to the development of particular software tools which now are combined in the PC-based integrated CARARA system. The options available in this system cover a wide range of reliability-oriented tasks, like organizing raw failure data in the component/event data bank FDB, performing statistical analysis of those data with the program FDA, managing the resulting parameters in the reliability data bank RDB, and performing fault tree analysis with the fault tree code FTL or evaluating the risk of toxic or radioactive material release with the STAR code. (orig.)

  18. Assessing the reliability of skilled performance

    International Nuclear Information System (INIS)

    Dougherty, E.M.; Collins, E.P.

    1996-01-01

    In some high-hazard military tasks, precision of motor skills is crucial to avoid a risk-sensitive drop or other mishap. Sparse data supports a basic level of reliability for this activity seemingly much lower than typical, individual action, slip-mode errors would yield. A typical occurrence failure rate seems to be of the order of 1 x 10 -5 per opportunity. A speculation is tendered that this represents a difference in kind; that the reliability of skills is a different taxon than previously called out in the typical scheme of human reliability

  19. A model for assessing human cognitive reliability in PRA studies

    International Nuclear Information System (INIS)

    Hannaman, G.W.; Spurgin, A.J.; Lukic, Y.

    1985-01-01

    This paper summarizes the status of a research project sponsored by EPRI as part of the Probabilistic Risk Assessment (PRA) technology improvement program and conducted by NUS Corporation to develop a model of Human Cognitive Reliability (HCR). The model was synthesized from features identified in a review of existing models. The model development was based on the hypothesis that the key factors affecting crew response times are separable. The inputs to the model consist of key parameters the values of which can be determined by PRA analysts for each accident situation being assessed. The output is a set of curves which represent the probability of control room crew non-response as a function of time for different conditions affecting their performance. The non-response probability is then a contributor to the overall non-success of operating crews to achieve a functional objective identified in the PRA study. Simulator data and some small scale tests were utilized to illustrate the calibration of interim HCR model coefficients for different types of cognitive processing since the data were sparse. The model can potentially help PRA analysts make human reliability assessments more explicit. The model incorporates concepts from psychological models of human cognitive behavior, information from current collections of human reliability data sources and crew response time data from simulator training exercises

  20. Statistical reliability assessment of software-based systems

    International Nuclear Information System (INIS)

    Korhonen, J.; Pulkkinen, U.; Haapanen, P.

    1997-01-01

    Plant vendors nowadays propose software-based systems even for the most critical safety functions. The reliability estimation of safety critical software-based systems is difficult since the conventional modeling techniques do not necessarily apply to the analysis of these systems, and the quantification seems to be impossible. Due to lack of operational experience and due to the nature of software faults, the conventional reliability estimation methods can not be applied. New methods are therefore needed for the safety assessment of software-based systems. In the research project Programmable automation systems in nuclear power plants (OHA), financed together by the Finnish Centre for Radiation and Nuclear Safety (STUK), the Ministry of Trade and Industry and the Technical Research Centre of Finland (VTT), various safety assessment methods and tools for software based systems are developed and evaluated. This volume in the OHA-report series deals with the statistical reliability assessment of software based systems on the basis of dynamic test results and qualitative evidence from the system design process. Other reports to be published later on in OHA-report series will handle the diversity requirements in safety critical software-based systems, generation of test data from operational profiles and handling of programmable automation in plant PSA-studies. (orig.) (25 refs.)

  1. Different Reliability Assessment Approaches for Wave Energy Converters

    DEFF Research Database (Denmark)

    Ambühl, Simon; Kramer, Morten Mejlhede; Sørensen, John Dalsgaard

    2015-01-01

    Reliability assessments are of importance for wave energy converters (WECs) due to the fact that accessibility might be limited in case of failure and maintenance. These failure rates can be adapted by reliability considerations. There are two different approaches to how reliability can...

  2. Probabilistic assessment of pressure vessel and piping reliability

    International Nuclear Information System (INIS)

    Sundararajan, C.

    1986-01-01

    The paper presents a critical review of the state-of-the-art in probabilistic assessment of pressure vessel and piping reliability. First the differences in assessing the reliability directly from historical failure data and indirectly by a probabilistic analysis of the failure phenomenon are discussed and the advantages and disadvantages are pointed out. The rest of the paper deals with the latter approach of reliability assessment. Methods of probabilistic reliability assessment are described and major projects where these methods are applied for pressure vessel and piping problems are discussed. An extensive list of references is provided at the end of the paper

  3. Parts and Components Reliability Assessment: A Cost Effective Approach

    Science.gov (United States)

    Lee, Lydia

    2009-01-01

    System reliability assessment is a methodology which incorporates reliability analyses performed at parts and components level such as Reliability Prediction, Failure Modes and Effects Analysis (FMEA) and Fault Tree Analysis (FTA) to assess risks, perform design tradeoffs, and therefore, to ensure effective productivity and/or mission success. The system reliability is used to optimize the product design to accommodate today?s mandated budget, manpower, and schedule constraints. Stand ard based reliability assessment is an effective approach consisting of reliability predictions together with other reliability analyses for electronic, electrical, and electro-mechanical (EEE) complex parts and components of large systems based on failure rate estimates published by the United States (U.S.) military or commercial standards and handbooks. Many of these standards are globally accepted and recognized. The reliability assessment is especially useful during the initial stages when the system design is still in the development and hard failure data is not yet available or manufacturers are not contractually obliged by their customers to publish the reliability estimates/predictions for their parts and components. This paper presents a methodology to assess system reliability using parts and components reliability estimates to ensure effective productivity and/or mission success in an efficient manner, low cost, and tight schedule.

  4. Results of a Demonstration Assessment of Passive System Reliability Utilizing the Reliability Method for Passive Systems (RMPS)

    Energy Technology Data Exchange (ETDEWEB)

    Bucknor, Matthew; Grabaskas, David; Brunett, Acacia; Grelle, Austin

    2015-04-26

    Advanced small modular reactor designs include many advantageous design features such as passively driven safety systems that are arguably more reliable and cost effective relative to conventional active systems. Despite their attractiveness, a reliability assessment of passive systems can be difficult using conventional reliability methods due to the nature of passive systems. Simple deviations in boundary conditions can induce functional failures in a passive system, and intermediate or unexpected operating modes can also occur. As part of an ongoing project, Argonne National Laboratory is investigating various methodologies to address passive system reliability. The Reliability Method for Passive Systems (RMPS), a systematic approach for examining reliability, is one technique chosen for this analysis. This methodology is combined with the Risk-Informed Safety Margin Characterization (RISMC) approach to assess the reliability of a passive system and the impact of its associated uncertainties. For this demonstration problem, an integrated plant model of an advanced small modular pool-type sodium fast reactor with a passive reactor cavity cooling system is subjected to a station blackout using RELAP5-3D. This paper discusses important aspects of the reliability assessment, including deployment of the methodology, the uncertainty identification and quantification process, and identification of key risk metrics.

  5. Process evaluation of the human reliability data bank

    International Nuclear Information System (INIS)

    Miller, D.P.; Comer, K.

    1985-01-01

    The US Nuclear Regulatory Commission and Sandia National Laboratories have been developing a plan for a human reliability data bank since August 1981. This research is in response to the data need of the nuclear power industry's probabilistic risk assessment community. The three phases of the program are to: (a) develop the data bank concept, (b) develop an implementation plan and conduct a process evaluation, and (c) assist a sponsor in implementing the data bank. The program is now in Phase B. This paper describes the methods used and the results of the process evaluation. Decisions to be made in the future regarding full-scale implementation will be based, in part, on the outcome of this study

  6. Process evaluation of the human reliability data bank

    International Nuclear Information System (INIS)

    Miller, D.P.; Comer, K.

    1984-01-01

    The US Nuclear Regulatory Commission and Sandia National Laboratories have been developing a plan for a human reliability data bank since August 1981. This research is in response to the data needs of the nuclear power industry's probabilistic risk assessment community. The three phases of the program are to: (A) develop the data bank concept, (B) develop an implementation plan and conduct a process evaluation, and (C) assist a sponsor in implementing the data bank. The program is now in Phase B. This paper describes the methods used and the results of the process evaluation. Decisions to be made in the future regarding full-scale implementation will be based in part on the outcome of this study

  7. Preliminary investigation on reliability assessment of passive safety system

    International Nuclear Information System (INIS)

    Huang Changfan; Kuang Bo

    2012-01-01

    The reliability evaluation of passive safety system plays an important part in probabilistic safety assessment (PSA) of nuclear power plant applying passive safety design, which depends quantitatively on reliabilities of passive safety system. According to the object of reliability assessment of passive safety system, relevant parameters are identified. Then passive system behavior during accident scenarios are studied. A practical example of this method is given for the case of reliability assessment of AP1000 passive heat removal system in loss of normal feedwater accident. Key and design parameters of PRHRS are identified and functional failure criteria are established. Parameter combinations acquired by Latin hyper~ cube sampling (LHS) in possible parametric ranges are input and calculations of uncertainty propagation through RELAP5/MOD3 code are carried out. Based on the calculations, sensitivity assessment on PRHRS functional criteria and reliability evaluation of the system are presented, which might provide further PSA with PRHR system reliability. (authors)

  8. Process plant equipment operation, control, and reliability

    CERN Document Server

    Holloway, Michael D; Onyewuenyi, Oliver A

    2012-01-01

    "Process Plant Equipment Book is another great publication from Wiley as a reference book for final year students as well as those who will work or are working in chemical production plants and refinery…" -Associate Prof. Dr. Ramli Mat, Deputy Dean (Academic), Faculty of Chemical Engineering, Universiti Teknologi Malaysia "…give[s] readers access to both fundamental information on process plant equipment and to practical ideas, best practices and experiences of highly successful engineers from around the world… The book is illustrated throughout with numerous black & white p

  9. Assessing Reliability of Cold Spray Sputter Targets in Photovoltaic Manufacturing

    Science.gov (United States)

    Hardikar, Kedar; Vlcek, Johannes; Bheemreddy, Venkata; Juliano, Daniel

    2017-10-01

    Cold spray has been used to manufacture more than 800 Cu-In-Ga (CIG) sputter targets for deposition of high-efficiency photovoltaic thin films. It is a preferred technique since it enables high deposit purity and transfer of non-equilibrium alloy states to the target material. In this work, an integrated approach to reliability assessment of such targets with deposit weight in excess of 50 lb. is undertaken, involving thermal-mechanical characterization of the material in as-deposited condition, characterization of the interface adhesion on cylindrical substrate in as-deposited condition, and developing means to assess target integrity under thermal-mechanical loads during the physical vapor deposition (PVD) sputtering process. Mechanical characterization of cold spray deposited CIG alloy is accomplished through the use of indentation testing and adaptation of Brazilian disk test. A custom lever test was developed to characterize adhesion along the cylindrical interface between the CIG deposit and cylindrical substrate, overcoming limitations of current standards. A cohesive zone model for crack initiation and propagation at the deposit interface is developed and validated using the lever test and later used to simulate the potential catastrophic target failure in the PVD process. It is shown that this approach enables reliability assessment of sputter targets and improves robustness.

  10. Process related contaminations causing climatic reliability issues

    DEFF Research Database (Denmark)

    Jellesen, Morten Stendahl; Dutta, Mondira; Verdingovas, Vadimas

    2012-01-01

    contaminants during the wave and re-flow soldering process; however variation in temperature on the PCBA surface during soldering can result in considerable amounts of active residues being left locally. Typical no-clean flux systems used today consist of weak organic acids (WOA) and active residues left...

  11. Representative process sampling for reliable data analysis

    DEFF Research Database (Denmark)

    Julius, Lars Petersen; Esbensen, Kim

    2005-01-01

    (sampling variances) can be reduced greatly however, and sampling biases can be eliminated completely, by respecting a simple set of rules and guidelines provided by TOS. A systematic approach for description of process heterogeneity furnishes in-depth knowledge about the specific variability of any 1-D lot...

  12. Reliability assessment of underground shaft closure

    International Nuclear Information System (INIS)

    Fossum, A.F.; Munson, D.E.

    1994-01-01

    The intent of the WIPP, being constructed in the bedded geologic salt deposits of Southeastern New Mexico, is to provide the technological basis for the safe disposal of radioactive Transuranic (TRU) wastes generated by the defense programs of the United States. In determining this technological basis, advanced reliability and structural analysis techniques are used to determine the probability of time-to-closure of a hypothetical underground shaft located in an argillaceous salt formation and filled with compacted crushed salt. Before being filled with crushed salt for sealing, the shaft provides access to an underground facility. Reliable closure of the shaft depends upon the sealing of the shaft through creep closure and recompaction of crushed backfill. Appropriate methods are demonstrated to calculate cumulative distribution functions of the closure based on laboratory determined random variable uncertainty in salt creep properties

  13. Risk and reliability assessment for telecommunications networks

    Energy Technology Data Exchange (ETDEWEB)

    Wyss, G.D.; Schriner, H.K.; Gaylor, T.R.

    1996-08-01

    Sandia National Laboratories has assembled an interdisciplinary team to explore the applicability of probabilistic logic modeling (PLM) techniques to model network reliability for a wide variety of communications network architectures. The authors have found that the reliability and failure modes of current generation network technologies can be effectively modeled using fault tree PLM techniques. They have developed a ``plug-and-play`` fault tree analysis methodology that can be used to model connectivity and the provision of network services in a wide variety of current generation network architectures. They have also developed an efficient search algorithm that can be used to determine the minimal cut sets of an arbitrarily-interconnected (non-hierarchical) network without the construction of a fault tree model. This paper provides an overview of these modeling techniques and describes how they are applied to networks that exhibit hybrid network structures (i.e., a network in which some areas are hierarchical and some areas are not hierarchical).

  14. Suprahyoid Muscle Complex: A Reliable Neural Assessment Tool For Dysphagia?

    DEFF Research Database (Denmark)

    Kothari, Mohit; Stubbs, Peter William; Pedersen, Asger Roer

    be a non-invasive reliable neural assessment tool for patients with dysphagia. Objective: To investigate the possibility of using the suprahyoid muscle complex (SMC) using surface electromyography (sEMG) to assess changes to neural pathways by determining the reliability of measurements in healthy...

  15. Reliability of assessment of adherence to an antimicrobial treatment guideline

    NARCIS (Netherlands)

    Mol, PGM; Gans, ROB; Panday, PVN; Degener, JE; Laseur, M; Haaijer-Ruskamp, FM

    Assessment procedures for adherence to a guideline must be reliable and credible. The aim of this study was to explore the reliability of assessment of adherence, taking account of the professional backgrounds of the observers. A secondary analysis explored the impact of case characteristics on

  16. Reliability assessment using the concept of possibility

    International Nuclear Information System (INIS)

    Ping, R.; Zhao, G.

    1994-01-01

    The role of the possibility theory in the quantitative approach to the reliability of large scale systems, in particular man-machine systems, is discussed. According to the original idea due to professor L.A. Zadeh, an error rate may be associated with a possibility distribution and a probability distribution. They describe the potentiallity and the actuality for error. This is especially important for the analysis of big accidents

  17. Extrapolation Method for System Reliability Assessment

    DEFF Research Database (Denmark)

    Qin, Jianjun; Nishijima, Kazuyoshi; Faber, Michael Havbro

    2012-01-01

    of integrals with scaled domains. The performance of this class of approximation depends on the approach applied for the scaling and the functional form utilized for the extrapolation. A scheme for this task is derived here taking basis in the theory of asymptotic solutions to multinormal probability integrals......The present paper presents a new scheme for probability integral solution for system reliability analysis, which takes basis in the approaches by Naess et al. (2009) and Bucher (2009). The idea is to evaluate the probability integral by extrapolation, based on a sequence of MC approximations...... that the proposed scheme is efficient and adds to generality for this class of approximations for probability integrals....

  18. Reliability and maintainability assessment factors for reliable fault-tolerant systems

    Science.gov (United States)

    Bavuso, S. J.

    1984-01-01

    A long term goal of the NASA Langley Research Center is the development of a reliability assessment methodology of sufficient power to enable the credible comparison of the stochastic attributes of one ultrareliable system design against others. This methodology, developed over a 10 year period, is a combined analytic and simulative technique. An analytic component is the Computer Aided Reliability Estimation capability, third generation, or simply CARE III. A simulative component is the Gate Logic Software Simulator capability, or GLOSS. The numerous factors that potentially have a degrading effect on system reliability and the ways in which these factors that are peculiar to highly reliable fault tolerant systems are accounted for in credible reliability assessments. Also presented are the modeling difficulties that result from their inclusion and the ways in which CARE III and GLOSS mitigate the intractability of the heretofore unworkable mathematics.

  19. Analysis and assessment of water treatment plant reliability

    Directory of Open Access Journals (Sweden)

    Szpak Dawid

    2017-03-01

    Full Text Available The subject of the publication is the analysis and assessment of the reliability of the surface water treatment plant (WTP. In the study the one parameter method of reliability assessment was used. Based on the flow sheet derived from the water company the reliability scheme of the analysed WTP was prepared. On the basis of the daily WTP work report the availability index Kg for the individual elements included in the WTP, was determined. Then, based on the developed reliability scheme showing the interrelationships between elements, the availability index Kg for the whole WTP was determined. The obtained value of the availability index Kg was compared with the criteria values.

  20. New process for weld metal reliability

    International Nuclear Information System (INIS)

    Hebel, A.G.

    1985-01-01

    The industry-wide nature of weld cracking alerts one to the possibility that there is a fundamental law being overlooked. And in overlooking this law, industry is unable to counteract it. That law mandates that restraint during welding causes internal stress; internal stress causes weld metal to crack. Component restraint during welding, according to the welding standard, is the major cause of weld metal failures. When the metal working industry accepts this fact and begins to counter the effects of restraint, the number of weld failures experienced fall dramatically. Bonal Technologies, inc., of Detroit, has developed the first consistently effective non-thermal process to relieve stress caused by restraint during welding. Bonal's patented Mets-Lax sub-resonant stress relief acts as a restraint neutralizer when used during welding. Meta-Lax weld conditioning produces a finer more uniform weld grain structure. A finer, more uniform grain structure is a clear metallurgical indication of improved mechanical weld properties. Other benefits like less internal stress, and less warpage are also achieved

  1. Reliability Estimation of the Pultrusion Process Using the First-Order Reliability Method (FORM)

    DEFF Research Database (Denmark)

    Baran, Ismet; Tutum, Cem Celal; Hattel, Jesper Henri

    2013-01-01

    In the present study the reliability estimation of the pultrusion process of a flat plate is analyzed by using the first order reliability method (FORM). The implementation of the numerical process model is validated by comparing the deterministic temperature and cure degree profiles...... with corresponding analyses in the literature. The centerline degree of cure at the exit (CDOCE) being less than a critical value and the maximum composite temperature (Tmax) during the process being greater than a critical temperature are selected as the limit state functions (LSFs) for the FORM. The cumulative...

  2. Process of performance assessment

    International Nuclear Information System (INIS)

    King, C.M.; Halford, D.K.

    1987-01-01

    Performance assessment is the process used to evaluate the environmental consequences of disposal of radioactive waste in the biosphere. An introductory review of the subject is presented. Emphasis is placed on the process of performance assessment from the standpoint of defining the process. Performance assessment, from evolving experience at DOE sites, has short-term and long-term subprograms, the components of which are discussed. The role of mathematical modeling in performance assessment is addressed including the pros and cons of current approaches. Finally, the system/site/technology issues as the focal point of this symposium are reviewed

  3. Assessing the Impact of Imperfect Diagnosis on Service Reliability

    DEFF Research Database (Denmark)

    Grønbæk, Lars Jesper; Schwefel, Hans-Peter; Kjærgaard, Jens Kristian

    2010-01-01

    , representative diagnosis performance metrics have been defined and their closed-form solutions obtained for the Markov model. These equations enable model parameterization from traces of implemented diagnosis components. The diagnosis model has been integrated in a reliability model assessing the impact...... of the diagnosis functions for the studied reliability problem. In a simulation study we finally analyze trade-off properties of diagnosis heuristics from literature, map them to the analytic Markov model, and investigate its suitability for service reliability optimization....

  4. PROVIDING RELIABILITY OF HUMAN RESOURCES IN PRODUCTION MANAGEMENT PROCESS

    Directory of Open Access Journals (Sweden)

    Anna MAZUR

    2014-07-01

    Full Text Available People are the most valuable asset of an organization and the results of a company mostly depends on them. The human factor can also be a weak link in the company and cause of the high risk for many of the processes. Reliability of the human factor in the process of the manufacturing process will depend on many factors. The authors include aspects of human error, safety culture, knowledge, communication skills, teamwork and leadership role in the developed model of reliability of human resources in the management of the production process. Based on the case study and the results of research and observation of the author present risk areas defined in a specific manufacturing process and the results of evaluation of the reliability of human resources in the process.

  5. Reliability analysis of common hazardous waste treatment processes

    International Nuclear Information System (INIS)

    Waters, R.D.

    1993-05-01

    Five hazardous waste treatment processes are analyzed probabilistically using Monte Carlo simulation to elucidate the relationships between process safety factors and reliability levels. The treatment processes evaluated are packed tower aeration, reverse osmosis, activated sludge, upflow anaerobic sludge blanket, and activated carbon adsorption

  6. Reliability analysis of common hazardous waste treatment processes

    Energy Technology Data Exchange (ETDEWEB)

    Waters, Robert D. [Vanderbilt Univ., Nashville, TN (United States)

    1993-05-01

    Five hazardous waste treatment processes are analyzed probabilistically using Monte Carlo simulation to elucidate the relationships between process safety factors and reliability levels. The treatment processes evaluated are packed tower aeration, reverse osmosis, activated sludge, upflow anaerobic sludge blanket, and activated carbon adsorption.

  7. A clinical assessment tool used for physiotherapy students--is it reliable?

    Science.gov (United States)

    Lewis, Lucy K; Stiller, Kathy; Hardy, Frances

    2008-01-01

    Educational institutions providing professional programs such as physiotherapy must provide high-quality student assessment procedures. To ensure that assessment is consistent, assessment tools should have an acceptable level of reliability. There is a paucity of research evaluating the reliability of clinical assessment tools used for physiotherapy students. This study evaluated the inter- and intrarater reliability of an assessment tool used for physiotherapy students during a clinical placement. Five clinical educators and one academic participated in the study. Each rater independently marked 22 student written assessments that had been completed by students after viewing a videotaped patient physiotherapy assessment. The raters repeated the marking process 7 weeks later, with the assessments provided in a randomised order. The interrater reliability (Intraclass Correlation Coefficient) for the total scores was 0.32, representing a poor level of reliability. A high level of intrarater reliability (percentage agreement) was found for the clinical educators, with a difference in section scores of one mark or less on 93.4% of occasions. Further research should be undertaken to reevaluate the reliability of this clinical assessment tool following training. The reliability of clinical assessment tools used in other areas of physiotherapy education should be formally measured rather than assumed.

  8. Probabilistic simulation applications to reliability assessments

    International Nuclear Information System (INIS)

    Miller, Ian; Nutt, Mark W.; Hill, Ralph S. III

    2003-01-01

    Probabilistic risk/reliability (PRA) analyses for engineered systems are conventionally based on fault-tree methods. These methods are mature and efficient, and are well suited to systems consisting of interacting components with known, low probabilities of failure. Even complex systems, such as nuclear power plants or aircraft, are modeled by the careful application of these approaches. However, for systems that may evolve in complex and nonlinear ways, and where the performance of components may be a sensitive function of the history of their working environments, fault-tree methods can be very demanding. This paper proposes an alternative method of evaluating such systems, based on probabilistic simulation using intelligent software objects to represent the components of such systems. Using a Monte Carlo approach, simulation models can be constructed from relatively simple interacting objects that capture the essential behavior of the components that they represent. Such models are capable of reflecting the complex behaviors of the systems that they represent in a natural and realistic way. (author)

  9. Systems reliability analysis: applications of the SPARCS System-Reliability Assessment Computer Program

    International Nuclear Information System (INIS)

    Locks, M.O.

    1978-01-01

    SPARCS-2 (Simulation Program for Assessing the Reliabilities of Complex Systems, Version 2) is a PL/1 computer program for assessing (establishing interval estimates for) the reliability and the MTBF of a large and complex s-coherent system of any modular configuration. The system can consist of a complex logical assembly of independently failing attribute (binomial-Bernoulli) and time-to-failure (Poisson-exponential) components, without regard to their placement. Alternatively, it can be a configuration of independently failing modules, where each module has either or both attribute and time-to-failure components. SPARCS-2 also has an improved super modularity feature. Modules with minimal-cut unreliabiliy calculations can be mixed with those having minimal-path reliability calculations. All output has been standardized to system reliability or probability of success, regardless of the form in which the input data is presented, and whatever the configuration of modules or elements within modules

  10. 75 FR 66038 - Planning Resource Adequacy Assessment Reliability Standard

    Science.gov (United States)

    2010-10-27

    ..., providing a common framework for resource adequacy analysis, assessment, and documentation) effectively and...://www.nerc.com/commondocs.php?cd=2 . D. Proposed Effective Date 24. Proposed regional Reliability...

  11. NPTool: Towards Scalability and Reliability of Business Process Management

    Science.gov (United States)

    Braghetto, Kelly Rosa; Ferreira, João Eduardo; Pu, Calton

    Currently one important challenge in business process management is provide at the same time scalability and reliability of business process executions. This difficulty becomes more accentuated when the execution control assumes complex countless business processes. This work presents NavigationPlanTool (NPTool), a tool to control the execution of business processes. NPTool is supported by Navigation Plan Definition Language (NPDL), a language for business processes specification that uses process algebra as formal foundation. NPTool implements the NPDL language as a SQL extension. The main contribution of this paper is a description of the NPTool showing how the process algebra features combined with a relational database model can be used to provide a scalable and reliable control in the execution of business processes. The next steps of NPTool include reuse of control-flow patterns and support to data flow management.

  12. Human reliability assessment on the basis of operating experience

    International Nuclear Information System (INIS)

    Straeter, O.

    1997-01-01

    For development of methodology, available models for qualitative assessment of human errors (e.g. by Swain, Hacker, Rasmussen) and a variety of known systematic approaches for quantitiative assessment of inadequate human action (e.g. THERP, ASEP, HCR, SLIM) were taken as a basis to establish a job specification, which in turn was used for developing a method for acquisition, characterisation and evaluation of errors. This method encompasses the two processes of event analysis and event evaluation: The first step comprises analysis of events by analysis of information describing the conditions and scenarios of relevance to the inadequate human action examined. In addition to the description of process sequences, information is taken into account on possible conditions that may bring about failure. As an assessment of human reliability requires manifold approaches for evaluation, a connectionistic procedure was developed for evaluation of the compilation of events based on a debate about various approaches from the domain of artificial intelligence (AI). This procedure yields both qualitative and quantitative information through a homogenous approach. (orig./GL) [de

  13. Reliability and comparison of acromion assessment techniques on x-ray and magnetic resonance imaging (reliability of acromion assessment techniques)

    International Nuclear Information System (INIS)

    Viskontas, D.G.; MacDermid, J.C.; Drosdowech, D.S.; Garvin, G.J.; Romano, W.M.; Faber, K.J.

    2005-01-01

    To determine the reliability and correlation of plain radiography and magnetic resonance imaging (MRI) in the assessment of acromion morphology. Materials and Methods: Acromion morphology was assessed using the lateral acromion angle (LAA) and the acromion-humeral interval (AHI). Thirty patients who had x-rays and MRI for impingement syndrome were included. Six blinded observers assessed the acromion morphology subjectively and objectively. Results: Neither acromion assessment technique demonstrated a positive correlation (kappa and intraclass coefficient 0.55) when measured objectively by experienced observers. Conclusion: The LAA and the AHI are both reliable acromion assessment techniques on X-ray and MRI when measured objectively and by experienced observers. (author)

  14. Reliability and Probabilistic Risk Assessment - How They Play Together

    Science.gov (United States)

    Safie, Fayssal M.; Stutts, Richard; Huang, Zhaofeng

    2015-01-01

    The objective of this presentation is to discuss the PRA process and the reliability engineering discipline, their differences and similarities, and how they are used as complimentary analyses to support design and flight decisions.

  15. Usage models in reliability assessment of software-based systems

    Energy Technology Data Exchange (ETDEWEB)

    Haapanen, P.; Pulkkinen, U. [VTT Automation, Espoo (Finland); Korhonen, J. [VTT Electronics, Espoo (Finland)

    1997-04-01

    This volume in the OHA-project report series deals with the statistical reliability assessment of software based systems on the basis of dynamic test results and qualitative evidence from the system design process. Other reports to be published later on in the OHA-project report series will handle the diversity requirements in safety critical software-based systems, generation of test data from operational profiles and handling of programmable automation in plant PSA-studies. In this report the issues related to the statistical testing and especially automated test case generation are considered. The goal is to find an efficient method for building usage models for the generation of statistically significant set of test cases and to gather practical experiences from this method by applying it in a case study. The scope of the study also includes the tool support for the method, as the models may grow quite large and complex. (32 refs., 30 figs.).

  16. Usage models in reliability assessment of software-based systems

    International Nuclear Information System (INIS)

    Haapanen, P.; Pulkkinen, U.; Korhonen, J.

    1997-04-01

    This volume in the OHA-project report series deals with the statistical reliability assessment of software based systems on the basis of dynamic test results and qualitative evidence from the system design process. Other reports to be published later on in the OHA-project report series will handle the diversity requirements in safety critical software-based systems, generation of test data from operational profiles and handling of programmable automation in plant PSA-studies. In this report the issues related to the statistical testing and especially automated test case generation are considered. The goal is to find an efficient method for building usage models for the generation of statistically significant set of test cases and to gather practical experiences from this method by applying it in a case study. The scope of the study also includes the tool support for the method, as the models may grow quite large and complex. (32 refs., 30 figs.)

  17. Time-dependent reliability analysis and condition assessment of structures

    International Nuclear Information System (INIS)

    Ellingwood, B.R.

    1997-01-01

    Structures generally play a passive role in assurance of safety in nuclear plant operation, but are important if the plant is to withstand the effect of extreme environmental or abnormal events. Relative to mechanical and electrical components, structural systems and components would be difficult and costly to replace. While the performance of steel or reinforced concrete structures in service generally has been very good, their strengths may deteriorate during an extended service life as a result of changes brought on by an aggressive environment, excessive loading, or accidental loading. Quantitative tools for condition assessment of aging structures can be developed using time-dependent structural reliability analysis methods. Such methods provide a framework for addressing the uncertainties attendant to aging in the decision process

  18. Translation, reliability, and clinical utility of the Melbourne Assessment 2.

    Science.gov (United States)

    Gerber, Corinna N; Plebani, Anael; Labruyère, Rob

    2017-10-12

    The aims were to (i) provide a German translation of the Melbourne Assessment 2 (MA2), a quantitative test to measure unilateral upper limb function in children with neurological disabilities and (ii) to evaluate its reliability and aspects of clinical utility. After its translation into German and approval of the back translation by the original authors, the MA2 was performed and videotaped twice with 30 children with neuromotor disorders. For each participant, two raters scored the video of the first test for inter-rater reliability. To determine test-retest reliability, one rater additionally scored the video of the second test while the other rater repeated the scoring of the first video to evaluate intra-rater reliability. Time needed for rater training, test administration, and scoring was recorded. The four subscale scores showed excellent intra-, inter-rater, and test-retest reliability with intraclass correlation coefficients of 0.90-1.00 (95%-confidence intervals 0.78-1.00). Score items revealed substantial to almost perfect intra-rater reliability (weighted kappa k w  = 0.66-1.00) for the more affected side. Score item inter-rater and test-retest reliability of the same extremity were, with one exception, moderate to almost perfect (k w  = 0.42-0.97; k w  = 0.40-0.89). Furthermore, the MA2 was feasible and acceptable for patients and clinicians. The MA2 showed excellent subscale and moderate to almost perfect score item reliability. Implications for Rehabilitation There is a lack of high-quality studies about psychometric properties of upper limb measurement tools in the neuropediatric population. The Melbourne Assessment 2 is a promising tool for reliable measurement of unilateral upper limb movement quality in the neuropediatric population. The Melbourne Assessment 2 is acceptable and practicable to therapists and patients for routine use in clinical care.

  19. Modelling and estimating degradation processes with application in structural reliability

    International Nuclear Information System (INIS)

    Chiquet, J.

    2007-06-01

    The characteristic level of degradation of a given structure is modeled through a stochastic process called the degradation process. The random evolution of the degradation process is governed by a differential system with Markovian environment. We put the associated reliability framework by considering the failure of the structure once the degradation process reaches a critical threshold. A closed form solution of the reliability function is obtained thanks to Markov renewal theory. Then, we build an estimation methodology for the parameters of the stochastic processes involved. The estimation methods and the theoretical results, as well as the associated numerical algorithms, are validated on simulated data sets. Our method is applied to the modelling of a real degradation mechanism, known as crack growth, for which an experimental data set is considered. (authors)

  20. Is the Frontal Assessment Battery reliable in ALS patients?

    NARCIS (Netherlands)

    Raaphorst, J.; Beeldman, E.; Jaeger, B.; Schmand, B.A.; Berg, L.H. van den; Weikamp, J.G.; Schelhaas, H.J.; Visser, M. de; Haan, R.J. de

    2013-01-01

    The assessment of frontal functions in ALS patients is important because of the overlap with the behavioural variant of frontotemporal dementia (bvFTD). We investigated the applicability and reliability of the Frontal Assessment Battery (FAB) within a cohort of predominantly prevalent ALS patients.

  1. Photographic assessment of burn size and depth: reliability and validity

    NARCIS (Netherlands)

    Hop, M.; Moues, C.; Bogomolova, K.; Nieuwenhuis, M.; Oen, I.; Middelkoop, E.; Breederveld, R.; de Baar, M.

    2014-01-01

    Objective: The aim of this study was to examine the reliability and validity of using photographs of burns to assess both burn size and depth. Method: Fifty randomly selected photographs taken on day 0-1 post burn were assessed by seven burn experts and eight referring physicians. Inter-rater

  2. Valid and Reliable Science Content Assessments for Science Teachers

    Science.gov (United States)

    Tretter, Thomas R.; Brown, Sherri L.; Bush, William S.; Saderholm, Jon C.; Holmes, Vicki-Lynn

    2013-01-01

    Science teachers' content knowledge is an important influence on student learning, highlighting an ongoing need for programs, and assessments of those programs, designed to support teacher learning of science. Valid and reliable assessments of teacher science knowledge are needed for direct measurement of this crucial variable. This paper…

  3. Reliability and validity of subjective assessment of lumbar lordosis in ...

    African Journals Online (AJOL)

    Radiological assessment of lumbar lordotic curve aids in early diagnosis of conditions even before neurologic changes set in. Objective: To ascertain the level of reliability and validity of subjective assessment of lumbar lordosis in conventional radiography. Design: A blinded, repeated-measures diagnostic test was carried ...

  4. Data driven CAN node reliability assessment for manufacturing system

    Science.gov (United States)

    Zhang, Leiming; Yuan, Yong; Lei, Yong

    2017-01-01

    The reliability of the Controller Area Network(CAN) is critical to the performance and safety of the system. However, direct bus-off time assessment tools are lacking in practice due to inaccessibility of the node information and the complexity of the node interactions upon errors. In order to measure the mean time to bus-off(MTTB) of all the nodes, a novel data driven node bus-off time assessment method for CAN network is proposed by directly using network error information. First, the corresponding network error event sequence for each node is constructed using multiple-layer network error information. Then, the generalized zero inflated Poisson process(GZIP) model is established for each node based on the error event sequence. Finally, the stochastic model is constructed to predict the MTTB of the node. The accelerated case studies with different error injection rates are conducted on a laboratory network to demonstrate the proposed method, where the network errors are generated by a computer controlled error injection system. Experiment results show that the MTTB of nodes predicted by the proposed method agree well with observations in the case studies. The proposed data driven node time to bus-off assessment method for CAN networks can successfully predict the MTTB of nodes by directly using network error event data.

  5. A computational Bayesian approach to dependency assessment in system reliability

    International Nuclear Information System (INIS)

    Yontay, Petek; Pan, Rong

    2016-01-01

    Due to the increasing complexity of engineered products, it is of great importance to develop a tool to assess reliability dependencies among components and systems under the uncertainty of system reliability structure. In this paper, a Bayesian network approach is proposed for evaluating the conditional probability of failure within a complex system, using a multilevel system configuration. Coupling with Bayesian inference, the posterior distributions of these conditional probabilities can be estimated by combining failure information and expert opinions at both system and component levels. Three data scenarios are considered in this study, and they demonstrate that, with the quantification of the stochastic relationship of reliability within a system, the dependency structure in system reliability can be gradually revealed by the data collected at different system levels. - Highlights: • A Bayesian network representation of system reliability is presented. • Bayesian inference methods for assessing dependencies in system reliability are developed. • Complete and incomplete data scenarios are discussed. • The proposed approach is able to integrate reliability information from multiple sources at multiple levels of the system.

  6. Reliability of sonographic assessment of tendinopathy in tennis elbow.

    Science.gov (United States)

    Poltawski, Leon; Ali, Syed; Jayaram, Vijay; Watson, Tim

    2012-01-01

    To assess the reliability and compute the minimum detectable change using sonographic scales to quantify the extent of pathology and hyperaemia in the common extensor tendon in people with tennis elbow. The lateral elbows of 19 people with tennis elbow were assessed sonographically twice, 1-2 weeks apart. Greyscale and power Doppler images were recorded for subsequent rating of abnormalities. Tendon thickening, hypoechogenicity, fibrillar disruption and calcification were each rated on four-point scales, and scores were summed to provide an overall rating of structural abnormality; hyperaemia was scored on a five point scale. Inter-rater reliability was established using the intraclass correlation coefficient (ICC) to compare scores assigned independently to the same set of images by a radiologist and a physiotherapist with training in musculoskeletal imaging. Test-retest reliability was assessed by comparing scores assigned by the physiotherapist to images recorded at the two sessions. The minimum detectable change (MDC) was calculated from the test-retest reliability data. ICC values for inter-rater reliability ranged from 0.35 (95% CI: 0.05, 0.60) for fibrillar disruption to 0.77 (0.55, 0.88) for overall greyscale score, and 0.89 (0.79, 0.95) for hyperaemia. Test-retest reliability ranged from 0.70 (0.48, 0.84) for tendon thickening to 0.82 (0.66, 0.90) for overall greyscale score and 0.86 (0.73, 0.93) for calcification. The MDC for the greyscale total score was 2.0/12 and for the hyperaemia score was 1.1/5. The sonographic scoring system used in this study may be used reliably to quantify tendon abnormalities and change over time. A relatively inexperienced imager can conduct the assessment and use the rating scales reliably.

  7. Techniques, processes, and measures for software safety and reliability

    International Nuclear Information System (INIS)

    Sparkman, D.

    1992-01-01

    The purpose of this report is to provide a detailed survey of current recommended practices and measurement techniques for the development of reliable and safe software-based systems. This report is intended to assist the United States Nuclear Reaction Regulation (NRR) in determining the importance and maturity of the available techniques and in assessing the relevance of individual standards for application to instrumentation and control systems in nuclear power generating stations. Lawrence Livermore National Laboratory (LLNL) provides technical support for the Instrumentation and Control System Branch (ICSB) of NRRin advanced instrumentation and control systems, distributed digital systems, software reliability, and the application of verificafion and validafion for the development of software

  8. Assessment of modern methods of human factor reliability analysis in PSA studies

    International Nuclear Information System (INIS)

    Holy, J.

    2001-12-01

    The report is structured as follows: Classical terms and objects (Probabilistic safety assessment as a framework for human reliability assessment; Human failure within the PSA model; Basic types of operator failure modelled in a PSA study and analyzed by HRA methods; Qualitative analysis of human reliability; Quantitative analysis of human reliability used; Process of analysis of nuclear reactor operator reliability in a PSA study); New terms and objects (Analysis of dependences; Errors of omission; Errors of commission; Error forcing context); and Overview and brief assessment of human reliability analysis (Basic characteristics of the methods; Assets and drawbacks of the use of each of HRA method; History and prospects of the use of the methods). (P.A.)

  9. Review of Reliability Assessment of Westinghouse SSPS Using SPC by WEC

    International Nuclear Information System (INIS)

    Kang, H. T.; Chung, H. Y.

    2007-01-01

    Westinghouse Electric Company (WEC) has accomplished the reliability assessment of Westinghouse Solid State Protection System (SSPS) in KORI no. 2, 3, 4, and YGN no. 1, 2. In their studies, it is reported that creating a cost-effective plan for improving the reliability of the SSPS and at KORI no. 2, 3 and 4, and YGN no. 1, 2 should be needed while reducing their maintenance cost. In this paper, we reviewed the reliability assessment of Westinghouse SSPS analyzed in two performance standards, availability, and the maintenance expense using Statistic Process Control (SPC). As a result, it is concluded all plants have several failures reported but no effect on the system's availability, and the maintenance expense analysis did not reduce the current maintenance expense by 30%. Therefore, overall review for the reliability assessment is that a new strategy for cost-effective plan and/or upgrade approach for improving the reliability of the aging Westinghouse SSPS should be needed

  10. Reliable and valid assessment of Lichtenstein hernia repair skills

    DEFF Research Database (Denmark)

    Carlsen, C G; Lindorff Larsen, Karen; Funch-Jensen, P

    2014-01-01

    PURPOSE: Lichtenstein hernia repair is a common surgical procedure and one of the first procedures performed by a surgical trainee. However, formal assessment tools developed for this procedure are few and sparsely validated. The aim of this study was to determine the reliability and validity...... of an assessment tool designed to measure surgical skills in Lichtenstein hernia repair. METHODS: Key issues were identified through a focus group interview. On this basis, an assessment tool with eight items was designed. Ten surgeons and surgical trainees were video recorded while performing Lichtenstein hernia...... a significant difference between the three groups which indicates construct validity, p skills can be assessed blindly by a single rater in a reliable and valid fashion with the new procedure-specific assessment tool. We recommend this tool for future assessment...

  11. Assessment of structural reliability of precast concrete buildings

    Directory of Open Access Journals (Sweden)

    Koyankin Alexandr

    2018-01-01

    Full Text Available Precast housing construction is currently being under rapid development, however, reliability of building structures made from precast reinforced concrete cannot be assessed rationally due to insufficient research data on that subject. In this regard, experimental and numerical studies were conducted to assess structural reliability of precast buildings as described in the given paper. Experimental studies of full-scale and model samples were conducted; numerical studies were held based on finite element models using “Lira” software. The objects under study included fragment of flooring of a building under construction, full-size fragment of flooring, full-scale models of precast cross-beams-to-columns joints and joints between hollow-core floor slabs and precast and cast-in-place cross-beams. Conducted research enabled to perform an objective assessment of structural reliability of precast buildings.

  12. Assessing Process and Product

    DEFF Research Database (Denmark)

    Bennedsen, Jens; Caspersen, Michael E.

    2006-01-01

    The final assessment of a course must reflect its goals, and contents. An important goal of our introductory programming course is that the students learn a systematic approach for the development of computer programs. Having the programming process as learning objective naturally raises the ques...

  13. A new measurement of workload in Web application reliability assessment

    Directory of Open Access Journals (Sweden)

    CUI Xia

    2015-02-01

    Full Text Available Web application has been popular in various fields of social life.It becomes more and more important to study the reliability of Web application.In this paper the definition of Web application failure is firstly brought out,and then the definition of Web application reliability.By analyzing data in the IIS server logs and selecting corresponding usage and information delivery failure data,the paper study the feasibility of Web application reliability assessment from the perspective of Web software system based on IIS server logs.Because the usage for a Web site often has certain regularity,a new measurement of workload in Web application reliability assessment is raised.In this method,the unit is removed by weighted average technique;and the weights are assessed by setting objective function and optimization.Finally an experiment was raised for validation.The experiment result shows the assessment of Web application reliability base on the new workload is better.

  14. ASSESSING AND COMBINING RELIABILITY OF PROTEIN INTERACTION SOURCES

    Science.gov (United States)

    LEACH, SONIA; GABOW, AARON; HUNTER, LAWRENCE; GOLDBERG, DEBRA S.

    2008-01-01

    Integrating diverse sources of interaction information to create protein networks requires strategies sensitive to differences in accuracy and coverage of each source. Previous integration approaches calculate reliabilities of protein interaction information sources based on congruity to a designated ‘gold standard.’ In this paper, we provide a comparison of the two most popular existing approaches and propose a novel alternative for assessing reliabilities which does not require a gold standard. We identify a new method for combining the resultant reliabilities and compare it against an existing method. Further, we propose an extrinsic approach to evaluation of reliability estimates, considering their influence on the downstream tasks of inferring protein function and learning regulatory networks from expression data. Results using this evaluation method show 1) our method for reliability estimation is an attractive alternative to those requiring a gold standard and 2) the new method for combining reliabilities is less sensitive to noise in reliability assignments than the similar existing technique. PMID:17990508

  15. Assessment of the reliability of ultrasonic inspection methods

    International Nuclear Information System (INIS)

    Haines, N.F.; Langston, D.B.; Green, A.J.; Wilson, R.

    1982-01-01

    The reliability of NDT techniques has remained an open question for many years. A reliable technique may be defined as one that, when rigorously applied by a number of inspection teams, consistently finds then correctly sizes all defects of concern. In this paper we report an assessment of the reliability of defect detection by manual ultrasonic methods applied to the inspection of thick section pressure vessel weldments. Initially we consider the available data relating to the inherent physical capabilities of ultrasonic techniques to detect cracks in weldment and then, independently, we assess the likely variability in team to team performance when several teams are asked to follow the same specified test procedure. The two aspects of 'capability' and 'variability' are brought together to provide quantitative estimates of the overall reliability of ultrasonic inspection of thick section pressure vessel weldments based on currently existing data. The final section of the paper considers current research programmes on reliability and presents a view on how these will help to further improve NDT reliability. (author)

  16. Reliable and valid assessment of performance in thoracoscopy

    DEFF Research Database (Denmark)

    Konge, Lars; Lehnert, Per; Hansen, Henrik Jessen

    2012-01-01

    BACKGROUND: As we move toward competency-based education in medicine, we have lagged in developing competency-based evaluation methods. In the era of minimally invasive surgery, there is a need for a reliable and valid tool dedicated to measure competence in video-assisted thoracoscopic surgery....... The purpose of this study is to create such an assessment tool, and to explore its reliability and validity. METHODS: An expert group of physicians created an assessment tool consisting of 10 items rated on a five-point rating scale. The following factors were included: economy and confidence of movement...

  17. Reliability assessment for safety critical systems by statistical random testing

    International Nuclear Information System (INIS)

    Mills, S.E.

    1995-11-01

    In this report we present an overview of reliability assessment for software and focus on some basic aspects of assessing reliability for safety critical systems by statistical random testing. We also discuss possible deviations from some essential assumptions on which the general methodology is based. These deviations appear quite likely in practical applications. We present and discuss possible remedies and adjustments and then undertake applying this methodology to a portion of the SDS1 software. We also indicate shortcomings of the methodology and possible avenues to address to follow to address these problems. (author). 128 refs., 11 tabs., 31 figs

  18. Reliability assessment for safety critical systems by statistical random testing

    Energy Technology Data Exchange (ETDEWEB)

    Mills, S E [Carleton Univ., Ottawa, ON (Canada). Statistical Consulting Centre

    1995-11-01

    In this report we present an overview of reliability assessment for software and focus on some basic aspects of assessing reliability for safety critical systems by statistical random testing. We also discuss possible deviations from some essential assumptions on which the general methodology is based. These deviations appear quite likely in practical applications. We present and discuss possible remedies and adjustments and then undertake applying this methodology to a portion of the SDS1 software. We also indicate shortcomings of the methodology and possible avenues to address to follow to address these problems. (author). 128 refs., 11 tabs., 31 figs.

  19. Numerical Model based Reliability Estimation of Selective Laser Melting Process

    DEFF Research Database (Denmark)

    Mohanty, Sankhya; Hattel, Jesper Henri

    2014-01-01

    Selective laser melting is developing into a standard manufacturing technology with applications in various sectors. However, the process is still far from being at par with conventional processes such as welding and casting, the primary reason of which is the unreliability of the process. While...... of the selective laser melting process. A validated 3D finite-volume alternating-direction-implicit numerical technique is used to model the selective laser melting process, and is calibrated against results from single track formation experiments. Correlation coefficients are determined for process input...... parameters such as laser power, speed, beam profile, etc. Subsequently, uncertainties in the processing parameters are utilized to predict a range for the various outputs, using a Monte Carlo method based uncertainty analysis methodology, and the reliability of the process is established....

  20. Statistical reliability analyses of two wood plastic composite extrusion processes

    International Nuclear Information System (INIS)

    Crookston, Kevin A.; Mark Young, Timothy; Harper, David; Guess, Frank M.

    2011-01-01

    Estimates of the reliability of wood plastic composites (WPC) are explored for two industrial extrusion lines. The goal of the paper is to use parametric and non-parametric analyses to examine potential differences in the WPC metrics of reliability for the two extrusion lines that may be helpful for use by the practitioner. A parametric analysis of the extrusion lines reveals some similarities and disparities in the best models; however, a non-parametric analysis reveals unique and insightful differences between Kaplan-Meier survival curves for the modulus of elasticity (MOE) and modulus of rupture (MOR) of the WPC industrial data. The distinctive non-parametric comparisons indicate the source of the differences in strength between the 10.2% and 48.0% fractiles [3,183-3,517 MPa] for MOE and for MOR between the 2.0% and 95.1% fractiles [18.9-25.7 MPa]. Distribution fitting as related to selection of the proper statistical methods is discussed with relevance to estimating the reliability of WPC. The ability to detect statistical differences in the product reliability of WPC between extrusion processes may benefit WPC producers in improving product reliability and safety of this widely used house-decking product. The approach can be applied to many other safety and complex system lifetime comparisons.

  1. Reliability assessment of complex electromechanical systems under epistemic uncertainty

    International Nuclear Information System (INIS)

    Mi, Jinhua; Li, Yan-Feng; Yang, Yuan-Jian; Peng, Weiwen; Huang, Hong-Zhong

    2016-01-01

    The appearance of macro-engineering and mega-project have led to the increasing complexity of modern electromechanical systems (EMSs). The complexity of the system structure and failure mechanism makes it more difficult for reliability assessment of these systems. Uncertainty, dynamic and nonlinearity characteristics always exist in engineering systems due to the complexity introduced by the changing environments, lack of data and random interference. This paper presents a comprehensive study on the reliability assessment of complex systems. In view of the dynamic characteristics within the system, it makes use of the advantages of the dynamic fault tree (DFT) for characterizing system behaviors. The lifetime of system units can be expressed as bounded closed intervals by incorporating field failures, test data and design expertize. Then the coefficient of variation (COV) method is employed to estimate the parameters of life distributions. An extended probability-box (P-Box) is proposed to convey the present of epistemic uncertainty induced by the incomplete information about the data. By mapping the DFT into an equivalent Bayesian network (BN), relevant reliability parameters and indexes have been calculated. Furthermore, the Monte Carlo (MC) simulation method is utilized to compute the DFT model with consideration of system replacement policy. The results show that this integrated approach is more flexible and effective for assessing the reliability of complex dynamic systems. - Highlights: • A comprehensive study on the reliability assessment of complex system is presented. • An extended probability-box is proposed to convey the present of epistemic uncertainty. • The dynamic fault tree model is built. • Bayesian network and Monte Carlo simulation methods are used. • The reliability assessment of a complex electromechanical system is performed.

  2. Reliable and valid assessment of Lichtenstein hernia repair skills.

    Science.gov (United States)

    Carlsen, C G; Lindorff-Larsen, K; Funch-Jensen, P; Lund, L; Charles, P; Konge, L

    2014-08-01

    Lichtenstein hernia repair is a common surgical procedure and one of the first procedures performed by a surgical trainee. However, formal assessment tools developed for this procedure are few and sparsely validated. The aim of this study was to determine the reliability and validity of an assessment tool designed to measure surgical skills in Lichtenstein hernia repair. Key issues were identified through a focus group interview. On this basis, an assessment tool with eight items was designed. Ten surgeons and surgical trainees were video recorded while performing Lichtenstein hernia repair, (four experts, three intermediates, and three novices). The videos were blindly and individually assessed by three raters (surgical consultants) using the assessment tool. Based on these assessments, validity and reliability were explored. The internal consistency of the items was high (Cronbach's alpha = 0.97). The inter-rater reliability was very good with an intra-class correlation coefficient (ICC) = 0.93. Generalizability analysis showed a coefficient above 0.8 even with one rater. The coefficient improved to 0.92 if three raters were used. One-way analysis of variance found a significant difference between the three groups which indicates construct validity, p fashion with the new procedure-specific assessment tool. We recommend this tool for future assessment of trainees performing Lichtenstein hernia repair to ensure that the objectives of competency-based surgical training are met.

  3. Human reliability analysis methods for probabilistic safety assessment

    International Nuclear Information System (INIS)

    Pyy, P.

    2000-11-01

    Human reliability analysis (HRA) of a probabilistic safety assessment (PSA) includes identifying human actions from safety point of view, modelling the most important of them in PSA models, and assessing their probabilities. As manifested by many incidents and studies, human actions may have both positive and negative effect on safety and economy. Human reliability analysis is one of the areas of probabilistic safety assessment (PSA) that has direct applications outside the nuclear industry. The thesis focuses upon developments in human reliability analysis methods and data. The aim is to support PSA by extending the applicability of HRA. The thesis consists of six publications and a summary. The summary includes general considerations and a discussion about human actions in the nuclear power plant (NPP) environment. A condensed discussion about the results of the attached publications is then given, including new development in methods and data. At the end of the summary part, the contribution of the publications to good practice in HRA is presented. In the publications, studies based on the collection of data on maintenance-related failures, simulator runs and expert judgement are presented in order to extend the human reliability analysis database. Furthermore, methodological frameworks are presented to perform a comprehensive HRA, including shutdown conditions, to study reliability of decision making, and to study the effects of wrong human actions. In the last publication, an interdisciplinary approach to analysing human decision making is presented. The publications also include practical applications of the presented methodological frameworks. (orig.)

  4. Achieving High Reliability with People, Processes, and Technology.

    Science.gov (United States)

    Saunders, Candice L; Brennan, John A

    2017-01-01

    High reliability as a corporate value in healthcare can be achieved by meeting the "Quadruple Aim" of improving population health, reducing per capita costs, enhancing the patient experience, and improving provider wellness. This drive starts with the board of trustees, CEO, and other senior leaders who ingrain high reliability throughout the organization. At WellStar Health System, the board developed an ambitious goal to become a top-decile health system in safety and quality metrics. To achieve this goal, WellStar has embarked on a journey toward high reliability and has committed to Lean management practices consistent with the Institute for Healthcare Improvement's definition of a high-reliability organization (HRO): one that is committed to the prevention of failure, early identification and mitigation of failure, and redesign of processes based on identifiable failures. In the end, a successful HRO can provide safe, effective, patient- and family-centered, timely, efficient, and equitable care through a convergence of people, processes, and technology.

  5. Reliable and Valid Assessment of Point-of-care Ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt

    2015-01-01

    physicians' OSAUS scores with diagnostic accuracy. RESULTS: The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores......OBJECTIVE: To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. BACKGROUND: POC US is increasingly used by clinicians and is an essential part of the management of acute surgical...... conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. METHODS: Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different...

  6. Validity and Reliability of Revised Inventory of Learning Processes.

    Science.gov (United States)

    Gadzella, B. M.; And Others

    The Inventory of Learning Processes (ILP) was developed by Schmeck, Ribich, and Ramanaiah in 1977 as a self-report inventory to assess learning style through a behavioral-oriented approach. The ILP was revised by Schmeck in 1983. The Revised ILP contains six scales: (1) Deep Processing; (2) Elaborative Processing; (3) Shallow Processing; (4)…

  7. Windfarm Generation Assessment for ReliabilityAnalysis of Power Systems

    DEFF Research Database (Denmark)

    Negra, Nicola Barberis; Holmstrøm, Ole; Bak-Jensen, Birgitte

    2007-01-01

    Due to the fast development of wind generation in the past ten years, increasing interest has been paid to techniques for assessing different aspects of power systems with a large amount of installed wind generation. One of these aspects concerns power system reliability. Windfarm modelling plays...

  8. Windfarm generation assessment for reliability analysis of power systems

    DEFF Research Database (Denmark)

    Negra, N.B.; Holmstrøm, O.; Bak-Jensen, B.

    2007-01-01

    Due to the fast development of wind generation in the past ten years, increasing interest has been paid to techniques for assessing different aspects of power systems with a large amount of installed wind generation. One of these aspects concerns power system reliability. Windfarm modelling plays...

  9. Methodology for reliability, economic and environmental assessment of wave energy

    International Nuclear Information System (INIS)

    Thorpe, T.W.; Muirhead, S.

    1994-01-01

    As part of the Preliminary Actions in Wave Energy R and D for DG XII's Joule programme, methodologies were developed to facilitate assessment of the reliability, economics and environmental impact of wave energy. This paper outlines these methodologies, their limitations and areas requiring further R and D. (author)

  10. Reliable and Valid Assessment of Clinical Bronchoscopy Performance

    DEFF Research Database (Denmark)

    Konge, Lars; Larsen, Klaus Richter; Clementsen, Paul

    2012-01-01

    : The interrater reliability was high, with Cronbach's a = 0.86. Assessment of 3 bronchoscopies by a single rater had a generalizability coefficient of 0.84. The correlation between experience and performance was good (Pearson correlation = 0.76). There were significant differences between the groups for all...

  11. Assessment of the Reliability of Concrete Slab Bridges

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle; Jensen, F. M.; Middleton, C. R.

    This paper is based on research performed for the Highways Agency, London, UK under the project DPU/9/44 "Revision of Bridge Assessment Rules Based on Whole Life Performance: Concrete Bridges". It contains details of a methodology which can be used to generate Whole Life (WL) reliability profiles....

  12. Assessment of reliability of Greulich and Pyle (gp) method for ...

    African Journals Online (AJOL)

    Background: Greulich and Pyle standards are the most widely used age estimation standards all over the world. The applicability of the Greulich and Pyle standards to populations which differ from their reference population is often questioned. This study aimed to assess the reliability of Greulich and Pyle (GP) method for ...

  13. Reliability of scored patient generated subjective global assessment ...

    African Journals Online (AJOL)

    Objective: Establish the reliability of the scored Patient Generated-Subjective Global Assessment (PG-SGA) in determining nutritional status among Antiretroviral Therapy (ART) naive HIV-infected adults. Methods: A descriptive, cross sectional study among outpatient medical clinics, in The AIDS Support Organization ...

  14. Qualification Users' Perceptions and Experiences of Assessment Reliability

    Science.gov (United States)

    Chamberlain, Suzanne

    2013-01-01

    This paper presents the findings of a study designed to explore qualification users' perceptions and experiences of reliability in the context of national assessment outcomes in England. The study consisted of 17 focus groups conducted across six sectors of qualification users: students, teachers, trainee teachers, job-seekers, employers and…

  15. Risk assessment and reliability for low level radioactive waste disposal

    International Nuclear Information System (INIS)

    Gregory, P.O.; Jones, G.A.

    1986-01-01

    The reliability of critical design features at low-level radioactive waste disposal facilities is a major concern in the licensing of these structures. To date, no systematic methodology has been adopted to evaluate the geotechnical reliability of Uranium Mill Tailings Remedial Action (UMTRA) disposal facilities currently being designed and/or constructed. This paper discusses and critiques the deterministic methods currently used to evaluate UMTRA reliability. Because deterministic methods may not be applicable in some cases because of the unusually long design life of UMTRA facilities, it is proposed that a probabilistic risk assessment-based methodology be used as a secondary method to aid in the evaluating of geotechnical reliability of critical items. Similar methodologies have proven successful in evaluating the reliability of a variety of conventional earth structures. In this paper, an ''acceptable'' level of risk for UMTRA facilities is developed, an evaluation method is presented, and two example applications of the proposed methodology are provided for a generic UMTRA disposal facility. The proposed technique is shown to be a simple method which might be used to aid in reliability evaluations on a selective basis. Finally, other possible applications and the limitations of the proposed methodology are discussed

  16. The Reliability and Structure of the Classroom Assessment Scoring System in German Pre-Schools

    Science.gov (United States)

    Stuck, Andrea; Kammermeyer, Gisela; Roux, Susanna

    2016-01-01

    This study examined the reliability and structure of the Classroom Assessment Scoring System (CLASS; Pianta, R. C., K. M. La Paro, and B. K. Hamre. 2008. "Classroom Assessment Scoring System. Manual Pre-K." Baltimore, MD: Brookes) and the quality of interactional processes in a German pre-school setting, drawing on a sample of 390…

  17. Reliability of high power electron accelerators for radiation processing

    International Nuclear Information System (INIS)

    Zimek, Z.

    2011-01-01

    Accelerators applied for radiation processing are installed in industrial facilities where accelerator availability coefficient should be at the level of 95% to fulfill requirements according to industry standards. Usually the exploitation of electron accelerator reviles the number of short and few long lasting failures. Some technical shortages can be overcome by practical implementation the experience gained in accelerator technology development by different accelerator manufactures. The reliability/availability of high power accelerators for application in flue gas treatment process must be dramatically improved to meet industrial standards. Support of accelerator technology dedicated for environment protection should be provided by governmental and international institutions to overcome accelerator reliability/availability problem and high risk and low direct profit in this particular application. (author)

  18. Reliability of high power electron accelerators for radiation processing

    Energy Technology Data Exchange (ETDEWEB)

    Zimek, Z. [Department of Radiation Chemistry and Technology, Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    2011-07-01

    Accelerators applied for radiation processing are installed in industrial facilities where accelerator availability coefficient should be at the level of 95% to fulfill requirements according to industry standards. Usually the exploitation of electron accelerator reviles the number of short and few long lasting failures. Some technical shortages can be overcome by practical implementation the experience gained in accelerator technology development by different accelerator manufactures. The reliability/availability of high power accelerators for application in flue gas treatment process must be dramatically improved to meet industrial standards. Support of accelerator technology dedicated for environment protection should be provided by governmental and international institutions to overcome accelerator reliability/availability problem and high risk and low direct profit in this particular application. (author)

  19. Observer reliability in assessing placental maturity by histology.

    OpenAIRE

    Khong, T Y; Staples, A; Bendon, R W; Chambers, H M; Gould, S J; Knowles, S; Shen-Schwarz, S

    1995-01-01

    AIMS--To evaluate the ability of five experienced perinatal pathologists to assess placental maturity reliably by histology. METHODS--Twenty four haematoxylin and eosin slides, six each from placentas of 27, 31, 35, and 39 weeks' gestation, were circulated to five pathologists on three separate occasions. The slides were labelled with the correct or incorrect gestational ages. RESULTS--The mean absolute error over all 360 readings was 2.72 weeks. Only 54% of the slides were assessed within tw...

  20. An approach for assessing ALWR passive safety system reliability

    International Nuclear Information System (INIS)

    Hake, T.M.

    1991-01-01

    Many of the advanced light water reactor (ALWR) concepts proposed for the next generation of nuclear power plants rely on passive rather than active systems to perform safety functions. Despite the reduced redundancy of the passive systems as compared to active systems in current plants, the assertion is that the overall safety of the plant is enhanced due to the much higher expected reliability of the passive systems. In order to investigate this assertion, a study is being conducted at Sandia National Laboratories to evaluate the reliability of ALWR passive safety features in the context of probabilistic risk assessment (PRA). The purpose of this paper is to provide a brief overview of the approach to this study. The quantification of passive system reliability is not as straightforward as for active systems, due to the lack of operating experience, and to the greater uncertainty in the governing physical phenomena. Thus, the adequacy of current methods for evaluating system reliability must be assessed, and alternatives proposed if necessary. For this study, the Westinghouse Advanced Passive 600 MWe reactor (AP600) was chosen as the advanced reactor for analysis, because of the availability of AP600 design information. This study compares the reliability of AP600 emergency cooling system with that of corresponding systems in a current generation reactor

  1. Reliability of the Hazelbaker Assessment Tool for Lingual Frenulum Function

    Directory of Open Access Journals (Sweden)

    James Jennifer P

    2006-03-01

    Full Text Available Abstract Background About 3% of infants are born with a tongue-tie which may lead to breastfeeding problems such as ineffective latch, painful attachment or poor weight gain. The Hazelbaker Assessment Tool for Lingual Frenulum Function (HATLFF has been developed to give a quantitative assessment of the tongue-tie and recommendation about frenotomy (release of the frenulum. The aim of this study was to assess the inter-rater reliability of the HATLFF. Methods Fifty-eight infants referred to the Breastfeeding Education and Support Services (BESS at The Royal Women's Hospital for assessment of tongue-tie and 25 control infants were assessed by two clinicians independently. Results The Appearance items received kappas between about 0.4 to 0.6, which represents "moderate" reliability. The first three Function items (lateralization, lift and extension of tongue had kappa values over 0.65 which indicates "substantial" agreement. The four Function items relating to infant sucking (spread, cupping, peristalsis and snapback received low kappa values with insignificant p values. There was 96% agreement between the two assessors on the recommendation for frenotomy (kappa 0.92, excellent agreement. The study found that the Function Score can be more simply assessed using only the first three function items (ie not scoring the sucking items, with a cut-off of ≤4 for recommendation of frenotomy. Conclusion We found that the HATLFF has a high reliability in a study of infants with tongue-tie and control infants

  2. Reliability and criterion validity of an observation protocol for working technique assessments in cash register work.

    Science.gov (United States)

    Palm, Peter; Josephson, Malin; Mathiassen, Svend Erik; Kjellberg, Katarina

    2016-06-01

    We evaluated the intra- and inter-observer reliability and criterion validity of an observation protocol, developed in an iterative process involving practicing ergonomists, for assessment of working technique during cash register work for the purpose of preventing upper extremity symptoms. Two ergonomists independently assessed 17 15-min videos of cash register work on two occasions each, as a basis for examining reliability. Criterion validity was assessed by comparing these assessments with meticulous video-based analyses by researchers. Intra-observer reliability was acceptable (i.e. proportional agreement >0.7 and kappa >0.4) for 10/10 questions. Inter-observer reliability was acceptable for only 3/10 questions. An acceptable inter-observer reliability combined with an acceptable criterion validity was obtained only for one working technique aspect, 'Quality of movements'. Thus, major elements of the cashiers' working technique could not be assessed with an acceptable accuracy from short periods of observations by one observer, such as often desired by practitioners. Practitioner Summary: We examined an observation protocol for assessing working technique in cash register work. It was feasible in use, but inter-observer reliability and criterion validity were generally not acceptable when working technique aspects were assessed from short periods of work. We recommend the protocol to be used for educational purposes only.

  3. Nonspecialist Raters Can Provide Reliable Assessments of Procedural Skills

    DEFF Research Database (Denmark)

    Mahmood, Oria; Dagnæs, Julia; Bube, Sarah

    2018-01-01

    was significant (p Pearson's correlation of 0.77 for the nonspecialists and 0.75 for the specialists. The test-retest reliability showed the biggest difference between the 2 groups, 0.59 and 0.38 for the nonspecialist raters and the specialist raters, respectively (p ... was chosen as it is a simple procedural skill that is crucial to master in a resident urology program. RESULTS: The internal consistency of assessments was high, Cronbach's α = 0.93 and 0.95 for nonspecialist and specialist raters, respectively (p correlations). The interrater reliability...

  4. Quantitative reliability assessment for safety critical system software

    International Nuclear Information System (INIS)

    Chung, Dae Won; Kwon, Soon Man

    2005-01-01

    An essential issue in the replacement of the old analogue I and C to computer-based digital systems in nuclear power plants is the quantitative software reliability assessment. Software reliability models have been successfully applied to many industrial applications, but have the unfortunate drawback of requiring data from which one can formulate a model. Software which is developed for safety critical applications is frequently unable to produce such data for at least two reasons. First, the software is frequently one-of-a-kind, and second, it rarely fails. Safety critical software is normally expected to pass every unit test producing precious little failure data. The basic premise of the rare events approach is that well-tested software does not fail under normal routine and input signals, which means that failures must be triggered by unusual input data and computer states. The failure data found under the reasonable testing cases and testing time for these conditions should be considered for the quantitative reliability assessment. We will present the quantitative reliability assessment methodology of safety critical software for rare failure cases in this paper

  5. A Bayesian belief nets based quantitative software reliability assessment for PSA: COTS case study

    International Nuclear Information System (INIS)

    Eom, H. S.; Sung, T. Y.; Jeong, H. S.; Park, J. H.; Kang, H. G.; Lee, K. Y.; Park, J. K

    2002-03-01

    Current reliability assessments of safety critical software embedded in the digital systems in nuclear power plants are based on the rule-based qualitative assessment methods. Then recently practical needs require the quantitative features of software reliability for Probabilistic Safety Assessment (PSA) that is one of important methods being used in assessing the whole safety of nuclear power plant. But conventional quantitative software reliability assessment methods are not enough to get the necessary results in assessing the safety critical software used in nuclear power plants. Thus, current reliability assessment methods for these digital systems exclude the software part or use arbitrary values for the software reliability in the assessment. This reports discusses a Bayesian Belief Nets (BBN) based quantification method that models current qualitative software assessment in formal way and produces quantitative results required for PSA. Commercial Off-The-Shelf (COTS) software dedication process that KAERI developed was applied to the discussed BBN based method for evaluating the plausibility of the proposed method in PSA

  6. High reliability flow system - an assessment of pump reliability and optimisation of the number of pumps

    International Nuclear Information System (INIS)

    Butterfield, J.M.

    1981-01-01

    A system is considered where a number of pumps operate in parallel. Normally, all pumps operate, driven by main motors fed from the grid. Each pump has a pony motor fed from an individual battery supply. Each pony motor is normally running, but not engaged to the pump shaft. On demand, e.g. failure of grid supplies, each pony motor is designed to clutch-in automatically when the pump speed falls to a specified value. The probability of all the pony motors failing to clutch-in on demand must be demonstrated with 95% confidence to be less than 10 -8 per demand. This assessment considers how the required reliability of pony motor drives might be demonstrated in practice and the implications on choice of the number of pumps at the design stage. The assessment recognises that not only must the system prove to be extremely reliable, but that demonstration that reliability is adequate must be done during plant commissioning, with practical limits on the amount of testing performed. It is concluded that a minimum of eight pony motors should be provided, eight pumps each with one pony motor (preferred) or five pumps each with two independent pony motors. A minimum of two diverse pony motor systems should be provided. (author)

  7. Reliability Assessment of Transformerless PV Inverters considering Mission Profiles

    Directory of Open Access Journals (Sweden)

    Yongheng Yang

    2015-01-01

    Full Text Available Due to the small volume and high efficiency, transformerless inverters have gained much popularity in grid-connected PV applications, where minimizing leakage current injection is mandatory. This can be achieved by either modifying the modulation schemes or adding extra power switching devices, resulting in an uneven distribution of the power losses on the switching devices. Consequently, the device thermal loading is redistributed and thus may alter the entire inverter reliability performance, especially under a long-term operation. In this consideration, this paper assesses the device reliability of three transformerless inverters under a yearly mission profile (i.e., solar irradiance and ambient temperature. The mission profile is translated to device thermal loading, which is used for lifetime prediction. Comparison results reveal the lifetime mismatches among the power switching devices operating under the same condition, which offers new thoughts for a robust design and a reliable operation of grid-connected transformerless PV inverters with high efficiency.

  8. Reliability-based assessment of polyethylene pipe creep lifetime

    International Nuclear Information System (INIS)

    Khelif, Rabia; Chateauneuf, Alaa; Chaoui, Kamel

    2007-01-01

    Lifetime management of underground pipelines is mandatory for safe hydrocarbon transmission and distribution systems. The use of high-density polyethylene tubes subjected to internal pressure, external loading and environmental variations requires a reliability study in order to define the service limits and the optimal operating conditions. In service, the time-dependent phenomena, especially creep, take place during the pipe lifetime, leading to significant strength reduction. In this work, the reliability-based assessment of pipe lifetime models is carried out, in order to propose a probabilistic methodology for lifetime model selection and to determine the pipe safety levels as well as the most important parameters for pipeline reliability. This study is enhanced by parametric analysis on pipe configuration, gas pressure and operating temperature

  9. Reliability-based assessment of polyethylene pipe creep lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Khelif, Rabia [LaMI-UBP and IFMA, Campus de Clermont-Fd, Les Cezeaux, BP 265, 63175 Aubiere Cedex (France); LR3MI, Departement de Genie Mecanique, Universite Badji Mokhtar, BP 12, Annaba 23000 (Algeria)], E-mail: rabia.khelif@ifma.fr; Chateauneuf, Alaa [LGC-University Blaise Pascal, Campus des Cezeaux, BP 206, 63174 Aubiere Cedex (France)], E-mail: alaa.chateauneuf@polytech.univ-bpclermont.fr; Chaoui, Kamel [LR3MI, Departement de Genie Mecanique, Universite Badji Mokhtar, BP 12, Annaba 23000 (Algeria)], E-mail: chaoui@univ-annaba.org

    2007-12-15

    Lifetime management of underground pipelines is mandatory for safe hydrocarbon transmission and distribution systems. The use of high-density polyethylene tubes subjected to internal pressure, external loading and environmental variations requires a reliability study in order to define the service limits and the optimal operating conditions. In service, the time-dependent phenomena, especially creep, take place during the pipe lifetime, leading to significant strength reduction. In this work, the reliability-based assessment of pipe lifetime models is carried out, in order to propose a probabilistic methodology for lifetime model selection and to determine the pipe safety levels as well as the most important parameters for pipeline reliability. This study is enhanced by parametric analysis on pipe configuration, gas pressure and operating temperature.

  10. Reliability and Validity Assessment of a Linear Position Transducer

    Science.gov (United States)

    Garnacho-Castaño, Manuel V.; López-Lastra, Silvia; Maté-Muñoz, José L.

    2015-01-01

    The objectives of the study were to determine the validity and reliability of peak velocity (PV), average velocity (AV), peak power (PP) and average power (AP) measurements were made using a linear position transducer. Validity was assessed by comparing measurements simultaneously obtained using the Tendo Weightlifting Analyzer Systemi and T-Force Dynamic Measurement Systemr (Ergotech, Murcia, Spain) during two resistance exercises, bench press (BP) and full back squat (BS), performed by 71 trained male subjects. For the reliability study, a further 32 men completed both lifts using the Tendo Weightlifting Analyzer Systemz in two identical testing sessions one week apart (session 1 vs. session 2). Intraclass correlation coefficients (ICCs) indicating the validity of the Tendo Weightlifting Analyzer Systemi were high, with values ranging from 0.853 to 0.989. Systematic biases and random errors were low to moderate for almost all variables, being higher in the case of PP (bias ±157.56 W; error ±131.84 W). Proportional biases were identified for almost all variables. Test-retest reliability was strong with ICCs ranging from 0.922 to 0.988. Reliability results also showed minimal systematic biases and random errors, which were only significant for PP (bias -19.19 W; error ±67.57 W). Only PV recorded in the BS showed no significant proportional bias. The Tendo Weightlifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and estimating power in resistance exercises. The low biases and random errors observed here (mainly AV, AP) make this device a useful tool for monitoring resistance training. Key points This study determined the validity and reliability of peak velocity, average velocity, peak power and average power measurements made using a linear position transducer The Tendo Weight-lifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and power. PMID:25729300

  11. Seismic reliability assessment methodology for CANDU concrete containment structures-phase 11

    International Nuclear Information System (INIS)

    Hong, H.P.

    1996-07-01

    This study was undertaken to verify a set of load factors for reliability-based seismic evaluation of CANDU containment structures in Eastern Canada. Here, the new, site-specific, results of probabilistic seismic hazard assessment (response spectral velocity) were applied. It was found that the previously recommended load factors are relatively insensitive to the new seismic hazard information, and are adequate for a reliability-based seismic evaluation process. (author). 4 refs., 5 tabs., 9 figs

  12. Nanoscale deformation measurements for reliability assessment of material interfaces

    Science.gov (United States)

    Keller, Jürgen; Gollhardt, Astrid; Vogel, Dietmar; Michel, Bernd

    2006-03-01

    With the development and application of micro/nano electronic mechanical systems (MEMS, NEMS) for a variety of market segments new reliability issues will arise. The understanding of material interfaces is the key for a successful design for reliability of MEMS/NEMS and sensor systems. Furthermore in the field of BIOMEMS newly developed advanced materials and well known engineering materials are combined despite of fully developed reliability concepts for such devices and components. In addition the increasing interface-to volume ratio in highly integrated systems and nanoparticle filled materials are challenges for experimental reliability evaluation. New strategies for reliability assessment on the submicron scale are essential to fulfil the needs of future devices. In this paper a nanoscale resolution experimental method for the measurement of thermo-mechanical deformation at material interfaces is introduced. The determination of displacement fields is based on scanning probe microscopy (SPM) data. In-situ SPM scans of the analyzed object (i.e. material interface) are carried out at different thermo-mechanical load states. The obtained images are compared by grayscale cross correlation algorithms. This allows the tracking of local image patterns of the analyzed surface structure. The measurement results are full-field displacement fields with nanometer resolution. With the obtained data the mixed mode type of loading at material interfaces can be analyzed with highest resolution for future needs in micro system and nanotechnology.

  13. Equipment reliability process improvement and preventive maintenance optimization

    International Nuclear Information System (INIS)

    Darragi, M.; Georges, A.; Vaillancourt, R.; Komljenovic, D.; Croteau, M.

    2004-01-01

    The Gentilly-2 Nuclear Power Plant wants to optimize its preventive maintenance program through an Integrated Equipment Reliability Process. All equipment reliability related activities should be reviewed and optimized in a systematic approach especially for aging plants such as G2. This new approach has to be founded on best practices methods with the purpose of the rationalization of the preventive maintenance program and the performance monitoring of on-site systems, structures and components (SSC). A rational preventive maintenance strategy is based on optimized task scopes and frequencies depending on their applicability, critical effects on system safety and plant availability as well as cost-effectiveness. Preventive maintenance strategy efficiency is systematically monitored through degradation indicators. (author)

  14. Reliability Engineering for ATLAS Petascale Data Processing on the Grid

    CERN Document Server

    Golubkov, D V; The ATLAS collaboration; Vaniachine, A V

    2012-01-01

    The ATLAS detector is in its third year of continuous LHC running taking data for physics analysis. A starting point for ATLAS physics analysis is reconstruction of the raw data. First-pass processing takes place shortly after data taking, followed later by reprocessing of the raw data with updated software and calibrations to improve the quality of the reconstructed data for physics analysis. Data reprocessing involves a significant commitment of computing resources and is conducted on the Grid. The reconstruction of one petabyte of ATLAS data with 1B collision events from the LHC takes about three million core-hours. Petascale data processing on the Grid involves millions of data processing jobs. At such scales, the reprocessing must handle a continuous stream of failures. Automatic job resubmission recovers transient failures at the cost of CPU time used by the failed jobs. Orchestrating ATLAS data processing applications to ensure efficient usage of tens of thousands of CPU-cores, reliability engineering ...

  15. Mammography image assessment; validity and reliability of current scheme

    International Nuclear Information System (INIS)

    Hill, C.; Robinson, L.

    2015-01-01

    Mammographers currently score their own images according to criteria set out by Regional Quality Assurance. The criteria used are based on the ‘Perfect, Good, Moderate, Inadequate’ (PGMI) marking criteria established by the National Health Service Breast Screening Programme (NHSBSP) in their Quality Assurance Guidelines of 2006 1 . This document discusses the validity and reliability of the current mammography image assessment scheme. Commencing with a critical review of the literature this document sets out to highlight problems with the national approach to the use of marking schemes. The findings suggest that ‘PGMI’ scheme is flawed in terms of reliability and validity and is not universally applied across the UK. There also appear to be differences in schemes used by trainees and qualified mammographers. Initial recommendations are to be made in collaboration with colleagues within the National Health Service Breast Screening Programme (NHSBSP), Higher Education Centres, College of Radiographers and the Royal College of Radiologists in order to identify a mammography image appraisal scheme that is fit for purpose. - Highlights: • Currently no robust evidence based marking tools in use for the assessment of images in mammography. • Is current system valid, reliable and robust? • How can the current image assessment tool be improved? • Should students and qualified mammographers use the same tool? • What marking criteria are available for image assessment?

  16. Comparative reliability of structured versus unstructured interviews in the admission process of a residency program.

    Science.gov (United States)

    Blouin, Danielle; Day, Andrew G; Pavlov, Andrey

    2011-12-01

    Although never directly compared, structured interviews are reported as being more reliable than unstructured interviews. This study compared the reliability of both types of interview when applied to a common pool of applicants for positions in an emergency medicine residency program. In 2008, one structured interview was added to the two unstructured interviews traditionally used in our resident selection process. A formal job analysis using the critical incident technique guided the development of the structured interview tool. This tool consisted of 7 scenarios assessing 4 of the domains deemed essential for success as a resident in this program. The traditional interview tool assessed 5 general criteria. In addition to these criteria, the unstructured panel members were asked to rate each candidate on the same 4 essential domains rated by the structured panel members. All 3 panels interviewed all candidates. Main outcomes were the overall, interitem, and interrater reliabilities, the correlations between interview panels, and the dimensionality of each interview tool. Thirty candidates were interviewed. The overall reliability reached 0.43 for the structured interview, and 0.81 and 0.71 for the unstructured interviews. Analyses of the variance components showed a high interrater, low interitem reliability for the structured interview, and a high interrater, high interitem reliability for the unstructured interviews. The summary measures from the 2 unstructured interviews were significantly correlated, but neither was correlated with the structured interview. Only the structured interview was multidimensional. A structured interview did not yield a higher overall reliability than both unstructured interviews. The lower reliability is explained by a lower interitem reliability, which in turn is due to the multidimensionality of the interview tool. Both unstructured panels consistently rated a single dimension, even when prompted to assess the 4 specific domains

  17. Reliability Assessment for Low-cost Unmanned Aerial Vehicles

    Science.gov (United States)

    Freeman, Paul Michael

    Existing low-cost unmanned aerospace systems are unreliable, and engineers must blend reliability analysis with fault-tolerant control in novel ways. This dissertation introduces the University of Minnesota unmanned aerial vehicle flight research platform, a comprehensive simulation and flight test facility for reliability and fault-tolerance research. An industry-standard reliability assessment technique, the failure modes and effects analysis, is performed for an unmanned aircraft. Particular attention is afforded to the control surface and servo-actuation subsystem. Maintaining effector health is essential for safe flight; failures may lead to loss of control incidents. Failure likelihood, severity, and risk are qualitatively assessed for several effector failure modes. Design changes are recommended to improve aircraft reliability based on this analysis. Most notably, the control surfaces are split, providing independent actuation and dual-redundancy. The simulation models for control surface aerodynamic effects are updated to reflect the split surfaces using a first-principles geometric analysis. The failure modes and effects analysis is extended by using a high-fidelity nonlinear aircraft simulation. A trim state discovery is performed to identify the achievable steady, wings-level flight envelope of the healthy and damaged vehicle. Tolerance of elevator actuator failures is studied using familiar tools from linear systems analysis. This analysis reveals significant inherent performance limitations for candidate adaptive/reconfigurable control algorithms used for the vehicle. Moreover, it demonstrates how these tools can be applied in a design feedback loop to make safety-critical unmanned systems more reliable. Control surface impairments that do occur must be quickly and accurately detected. This dissertation also considers fault detection and identification for an unmanned aerial vehicle using model-based and model-free approaches and applies those

  18. Reliability-based condition assessment of steel containment and liners

    International Nuclear Information System (INIS)

    Ellingwood, B.; Bhattacharya, B.; Zheng, R.

    1996-11-01

    Steel containments and liners in nuclear power plants may be exposed to aggressive environments that may cause their strength and stiffness to decrease during the plant service life. Among the factors recognized as having the potential to cause structural deterioration are uniform, pitting or crevice corrosion; fatigue, including crack initiation and propagation to fracture; elevated temperature; and irradiation. The evaluation of steel containments and liners for continued service must provide assurance that they are able to withstand future extreme loads during the service period with a level of reliability that is sufficient for public safety. Rational methodologies to provide such assurances can be developed using modern structural reliability analysis principles that take uncertainties in loading, strength, and degradation resulting from environmental factors into account. The research described in this report is in support of the Steel Containments and Liners Program being conducted for the US Nuclear Regulatory Commission by the Oak Ridge National Laboratory. The research demonstrates the feasibility of using reliability analysis as a tool for performing condition assessments and service life predictions of steel containments and liners. Mathematical models that describe time-dependent changes in steel due to aggressive environmental factors are identified, and statistical data supporting the use of these models in time-dependent reliability analysis are summarized. The analysis of steel containment fragility is described, and simple illustrations of the impact on reliability of structural degradation are provided. The role of nondestructive evaluation in time-dependent reliability analysis, both in terms of defect detection and sizing, is examined. A Markov model provides a tool for accounting for time-dependent changes in damage condition of a structural component or system. 151 refs

  19. Development of the Concise Data Processing Assessment

    Directory of Open Access Journals (Sweden)

    James Day

    2011-06-01

    Full Text Available The Concise Data Processing Assessment (CDPA was developed to probe student abilities related to the nature of measurement and uncertainty and to handling data. The diagnostic is a ten question, multiple-choice test that can be used as both a pre-test and post-test. A key component of the development process was interviews with students, which were used to both uncover common modes of student thinking and validate item wording. To evaluate the reliability and discriminatory power of this diagnostic, we performed statistical tests focusing on both item analysis (item difficulty index, item discrimination index, and point-biserial coefficient and on the entire test (test reliability and Ferguson’s delta. Scores on the CDPA range from chance (for novices to about 80% (for experts, indicating that it possesses good dynamic range. Overall, the results indicate that the CDPA is a reliable assessment tool for measuring targeted abilities in undergraduate physics students.

  20. Interrater reliability of videotaped observational gait-analysis assessments.

    Science.gov (United States)

    Eastlack, M E; Arvidson, J; Snyder-Mackler, L; Danoff, J V; McGarvey, C L

    1991-06-01

    The purpose of this study was to determine the interrater reliability of videotaped observational gait-analysis (VOGA) assessments. Fifty-four licensed physical therapists with varying amounts of clinical experience served as raters. Three patients with rheumatoid arthritis who demonstrated an abnormal gait pattern served as subjects for the videotape. The raters analyzed each patient's most severely involved knee during the four subphases of stance for the kinematic variables of knee flexion and genu valgum. Raters were asked to determine whether these variables were inadequate, normal, or excessive. The temporospatial variables analyzed throughout the entire gait cycle were cadence, step length, stride length, stance time, and step width. Generalized kappa coefficients ranged from .11 to .52. Intraclass correlation coefficients (2,1) and (3,1) were slightly higher. Our results indicate that physical therapists' VOGA assessments are only slightly to moderately reliable and that improved interrater reliability of the assessments of physical therapists utilizing this technique is needed. Our data suggest that there is a need for greater standardization of gait-analysis training.

  1. Adhesives technology for electronic applications materials, processing, reliability

    CERN Document Server

    Licari, James J

    2011-01-01

    Adhesives are widely used in the manufacture and assembly of electronic circuits and products. Generally, electronics design engineers and manufacturing engineers are not well versed in adhesives, while adhesion chemists have a limited knowledge of electronics. This book bridges these knowledge gaps and is useful to both groups. The book includes chapters covering types of adhesive, the chemistry on which they are based, and their properties, applications, processes, specifications, and reliability. Coverage of toxicity, environmental impacts and the regulatory framework make this book par

  2. Full scale experimental assessment of reliability of steady state design criteria of activated sludge process with biological nitrogen removal and chemical phosphorus removal; Verifica sperimentale a scala reale di criteri di dimensionamento dei sistemi a fanghi attivi per la rimozione dei nutrienti

    Energy Technology Data Exchange (ETDEWEB)

    Tatano, F. [Politecnico di Milano, Milan (Italy). Dip. di Ingegneria Idraulica, Ambientale e del Rilevamento, Sez. Ambientale

    1996-06-01

    The biological phase of a wastewater treatment plant situated in the Ruhr River Region (Germany), has been monitored for about one year. The collected experimental data have been elaborated in this paper with the objective of an assessment of the reliability of some recent steady-state design criteria of the activated sludge process with biological nitrogen removal and chemical phosphorus removal.

  3. Reliability Assessment of Wind Farm Electrical System Based on a Probability Transfer Technique

    Directory of Open Access Journals (Sweden)

    Hejun Yang

    2018-03-01

    Full Text Available The electrical system of a wind farm has a significant influence on the wind farm reliability and electrical energy yield. The disconnect switch installed in an electrical system cannot only improve the operating flexibility, but also enhance the reliability for a wind farm. Therefore, this paper develops a probabilistic transfer technique for integrating the electrical topology structure, the isolation operation of disconnect switch, and stochastic failure of electrical equipment into the reliability assessment of wind farm electrical system. Firstly, as the traditional two-state reliability model of electrical equipment cannot consider the isolation operation, so the paper develops a three-state reliability model to replace the two-state model for incorporating the isolation operation. In addition, a proportion apportion technique is presented to evaluate the state probability. Secondly, this paper develops a probabilistic transfer technique based on the thoughts that through transfer the unreliability of electrical system to the energy transmission interruption of wind turbine generators (WTGs. Finally, some novel indices for describing the reliability of wind farm electrical system are designed, and the variance coefficient of the designed indices is used as a convergence criterion to determine the termination of the assessment process. The proposed technique is applied to the reliability assessment of a wind farm with the different topologies. The simulation results show that the proposed techniques are effective in practical applications.

  4. Reliability assessment of passive containment isolation system using APSRA methodology

    International Nuclear Information System (INIS)

    Nayak, A.K.; Jain, Vikas; Gartia, M.R.; Srivastava, A.; Prasad, Hari; Anthony, A.; Gaikwad, A.J.; Bhatia, S.; Sinha, R.K.

    2008-01-01

    In this paper, a methodology known as APSRA (Assessment of Passive System ReliAbility) has been employed for evaluation of the reliability of passive systems. The methodology has been applied to the passive containment isolation system (PCIS) of the Indian advanced heavy water reactor (AHWR). In the APSRA methodology, the passive system reliability evaluation is based on the failure probability of the system to carryout the desired function. The methodology first determines the operational characteristics of the system and the failure conditions by assigning a predetermined failure criterion. The failure surface is predicted using a best estimate code considering deviations of the operating parameters from their nominal states, which affect the PCIS performance. APSRA proposes to compare the code predictions with the test data to generate the uncertainties on the failure parameter prediction, which is later considered in the code for accurate prediction of failure surface of the system. Once the failure surface of the system is predicted, the cause of failure is examined through root diagnosis, which occurs mainly due to failure of mechanical components. The failure probability of these components is evaluated through a classical PSA treatment using the generic data. The reliability of the PCIS is evaluated from the probability of availability of the components for the success of the passive containment isolation system

  5. A reliability assessment methodology for the VHTR passive safety system

    International Nuclear Information System (INIS)

    Lee, Hyungsuk; Jae, Moosung

    2014-01-01

    The passive safety system of a VHTR (Very High Temperature Reactor), which has recently attracted worldwide attention, is currently being considered for the design of safety improvements for the next generation of nuclear power plants in Korea. The functionality of the passive system does not rely on an external source of an electrical support system, but on the intelligent use of natural phenomena. Its function involves an ultimate heat sink for a passive secondary auxiliary cooling system, especially during a station blackout such as the case of the Fukushima Daiichi reactor accidents. However, it is not easy to quantitatively evaluate the reliability of passive safety for the purpose of risk analysis, considering the existing active system failure since the classical reliability assessment method cannot be applied. Therefore, we present a new methodology to quantify the reliability based on reliability physics models. This evaluation framework is then applied to of the conceptually designed VHTR in Korea. The Response Surface Method (RSM) is also utilized for evaluating the uncertainty of the maximum temperature of nuclear fuel. The proposed method could contribute to evaluating accident sequence frequency and designing new innovative nuclear systems, such as the reactor cavity cooling system (RCCS) in VHTR to be designed and constructed in Korea.

  6. Reliability and Validity Assessment of a Linear Position Transducer

    Directory of Open Access Journals (Sweden)

    Manuel V. Garnacho-Castaño

    2015-03-01

    Full Text Available The objectives of the study were to determine the validity and reliability of peak velocity (PV, average velocity (AV, peak power (PP and average power (AP measurements were made using a linear position transducer. Validity was assessed by comparing measurements simultaneously obtained using the Tendo Weightlifting Analyzer Systemi and T-Force Dynamic Measurement Systemr (Ergotech, Murcia, Spain during two resistance exercises, bench press (BP and full back squat (BS, performed by 71 trained male subjects. For the reliability study, a further 32 men completed both lifts using the Tendo Weightlifting Analyzer Systemz in two identical testing sessions one week apart (session 1 vs. session 2. Intraclass correlation coefficients (ICCs indicating the validity of the Tendo Weightlifting Analyzer Systemi were high, with values ranging from 0.853 to 0.989. Systematic biases and random errors were low to moderate for almost all variables, being higher in the case of PP (bias ±157.56 W; error ±131.84 W. Proportional biases were identified for almost all variables. Test-retest reliability was strong with ICCs ranging from 0.922 to 0.988. Reliability results also showed minimal systematic biases and random errors, which were only significant for PP (bias -19.19 W; error ±67.57 W. Only PV recorded in the BS showed no significant proportional bias. The Tendo Weightlifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and estimating power in resistance exercises. The low biases and random errors observed here (mainly AV, AP make this device a useful tool for monitoring resistance training.

  7. Reliability Assessment of Transformerless PV Inverters Considering Mission Profiles

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2015-01-01

    reliability of three transformerless inverters under a yearly mission profile (i.e., solar irradiance and ambient temperature). The mission profile is translated to device thermal loading, which is used for lifetime prediction. Compar¬ison results reveal the lifetime mismatches among the power switching......Due to the small volume and high efficiency, transformerless inverters have gained much popularity in grid-connected PV applications, where minimizing leakage current injection is mandatory. This can be achieved either by modifying the modulation schemes or adding extra power switching devices......, resulting in an uneven distribution of the power losses on the switching devices. Consequently, the device thermal loading is redis-tributed, and thus may alter the entire inverter reliability performance, especially under a long-term operation. In this consideration, this paper assesses the device...

  8. Improving risk assessment by defining consistent and reliable system scenarios

    Directory of Open Access Journals (Sweden)

    B. Mazzorana

    2009-02-01

    Full Text Available During the entire procedure of risk assessment for hydrologic hazards, the selection of consistent and reliable scenarios, constructed in a strictly systematic way, is fundamental for the quality and reproducibility of the results. However, subjective assumptions on relevant impact variables such as sediment transport intensity on the system loading side and weak point response mechanisms repeatedly cause biases in the results, and consequently affect transparency and required quality standards. Furthermore, the system response of mitigation measures to extreme event loadings represents another key variable in hazard assessment, as well as the integral risk management including intervention planning. Formative Scenario Analysis, as a supplement to conventional risk assessment methods, is a technique to construct well-defined sets of assumptions to gain insight into a specific case and the potential system behaviour. By two case studies, carried out (1 to analyse sediment transport dynamics in a torrent section equipped with control measures, and (2 to identify hazards induced by woody debris transport at hydraulic weak points, the applicability of the Formative Scenario Analysis technique is presented. It is argued that during scenario planning in general and with respect to integral risk management in particular, Formative Scenario Analysis allows for the development of reliable and reproducible scenarios in order to design more specifically an application framework for the sustainable assessment of natural hazards impact. The overall aim is to optimise the hazard mapping and zoning procedure by methodologically integrating quantitative and qualitative knowledge.

  9. Recommended practices for wind farm data collection and reliability assessment for O&M optimization

    DEFF Research Database (Denmark)

    Hahn, Berthold; Welte, Thomas; Faulstich, Stefan

    2017-01-01

    . The complete results of IEA Wind Task 33 are described in the expert group report on recommended practices for "Wind farm data collection and reliability assessment for O&M optimization" which will be published by IEA Wind in 2017. This paper briefly presents the background of the work, the recommended process...

  10. Reliability assessment of creep rupture life for Gr. 91 steel

    International Nuclear Information System (INIS)

    Kim, Woo-Gon; Park, Jae-Young; Kim, Seon-Jin; Jang, Jinsung

    2013-01-01

    Highlights: • Statistical analysis of a number of creep rupture data based on Z parameter. • Determination of the constant C in LM parameter and long-term creep life prediction. • Generation of random variables for Z s and Z cr by Monte-Carlo simulation in a SCRI model. • Examples for design application were reasonably drawn from the viewpoints of reliability. - Abstract: This paper presents reliability assessment of the long-term creep life of Gr. 91 steel, which is a major structural material for high temperature structural components of Generation-IV reactor systems. A number of creep rupture data for Gr. 91 steel were collected through literature surveys, and the long-term creep life was predicted by Larson–Miller parameter. A “Z parameter” method was used to describe the magnitude of the deviation of the creep rupture data to a master curve. A “Service Condition-creep Rupture property Interference (SCRI) model” based on the Z parameter was used to simultaneously consider the scattering of the creep rupture data of materials and the fluctuations of service conditions in reliability assessment. A statistical analysis of the creep rupture data was conducted by the Z parameter. To carry out the SCRI model, a number of random variables for Z s describing service conditions and Z cr describing the dispersion of the creep rupture data were generated using a Monte-Carlo simulation technique. As examples for application, the creep rupture life under a certain service conditions of Gr. 91 steel was reasonably drawn from the viewpoints of reliability

  11. Reliability Omnipotent Analysis For First Stage Separator On The Separation Process Of Gas, Oil And Water

    International Nuclear Information System (INIS)

    Sony Tjahyani, D. T.; Ismu W, Puradwi; Asmara Santa, Sigit

    2001-01-01

    Reliability of industry can be evaluated based on two aspects which are risk and economic aspects. From these points, optimation value can be determined optimation value. Risk of the oil refinery process are fire and explosion, so assessment of this system must be done. One system of the oil refinery process is first stage separator which is used to separate gas, oil and water. Evaluation of reliability for first stage separator system has been done with FAMECA and HAZap method. The analysis results, the probability of fire and explosion of 1.1x10 - 2 3 /hour and 1.2x10 - 1 1 /hour, respectively. The reliability value of the system is high because each undesired event is anticipated with safety system or safety component

  12. Reliability, compliance, and security in web-based course assessments

    Directory of Open Access Journals (Sweden)

    Scott Bonham

    2008-04-01

    Full Text Available Pre- and postcourse assessment has become a very important tool for education research in physics and other areas. The web offers an attractive alternative to in-class paper administration, but concerns about web-based administration include reliability due to changes in medium, student compliance rates, and test security, both question leakage and utilization of web resources. An investigation was carried out in introductory astronomy courses comparing pre- and postcourse administration of assessments using the web and on paper. Overall no difference was seen in performance due to the medium. Compliance rates fluctuated greatly, and factors that seemed to produce higher rates are identified. Notably, email reminders increased compliance by 20%. Most of the 559 students complied with requests to not copy, print, or save questions nor use web resources; about 1% did copy some question text and around 2% frequently used other windows or applications while completing the assessment.

  13. A comparative evaluation of five human reliability assessment techniques

    International Nuclear Information System (INIS)

    Kirwan, B.

    1988-01-01

    A field experiment was undertaken to evaluate the accuracy, usefulness, and resources requirements of five human reliability quantification techniques (Techniques for Human Error Rate Prediction (THERP); Paired Comparisons, Human Error Assessment and Reduction Technique (HEART), Success Liklihood Index Method (SLIM)-Multi Attribute Utility Decomposition (MAUD), and Absolute Probability Judgement). This was achieved by assessing technique predictions against a set of known human error probabilities, and by comparing their predictions on a set of five realistic Probabilisitc Risk Assessment (PRA) human error. On a combined measure of accuracy THERP and Absolute Probability Judgement performed best, whilst HEART showed indications of accuracy and was lower in resources usage than other techniques. HEART and THERP both appear to benefit from using trained assessors in order to obtain the best results. SLIM and Paired Comparisons require further research on achieving a robust calibration relationship between their scale values and absolute probabilities. (author)

  14. Relevance and reliability of experimental data in human health risk assessment of pesticides.

    Science.gov (United States)

    Kaltenhäuser, Johanna; Kneuer, Carsten; Marx-Stoelting, Philip; Niemann, Lars; Schubert, Jens; Stein, Bernd; Solecki, Roland

    2017-08-01

    Evaluation of data relevance, reliability and contribution to uncertainty is crucial in regulatory health risk assessment if robust conclusions are to be drawn. Whether a specific study is used as key study, as additional information or not accepted depends in part on the criteria according to which its relevance and reliability are judged. In addition to GLP-compliant regulatory studies following OECD Test Guidelines, data from peer-reviewed scientific literature have to be evaluated in regulatory risk assessment of pesticide active substances. Publications should be taken into account if they are of acceptable relevance and reliability. Their contribution to the overall weight of evidence is influenced by factors including test organism, study design and statistical methods, as well as test item identification, documentation and reporting of results. Various reports make recommendations for improving the quality of risk assessments and different criteria catalogues have been published to support evaluation of data relevance and reliability. Their intention was to guide transparent decision making on the integration of the respective information into the regulatory process. This article describes an approach to assess the relevance and reliability of experimental data from guideline-compliant studies as well as from non-guideline studies published in the scientific literature in the specific context of uncertainty and risk assessment of pesticides. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Reliability assessment of aging structures subjected to gradual and shock deteriorations

    International Nuclear Information System (INIS)

    Wang, Cao; Zhang, Hao; Li, Quanwang

    2017-01-01

    Civil structures and infrastructure facilities are susceptible to deterioration posed by the effects of natural hazards and aggressive environmental conditions. These factors may increase the risk of service interruption of infrastructures, and should be taken into account when assessing the structural reliability during an infrastructure's service life. Modeling the resistance deterioration process reasonably is the basis for structural reliability analysis. In this paper, a novel model is developed for describing the deterioration of aging structures. The deterioration is a combination of two stochastic processes: the gradual deterioration posed by environmental effects and the shock deterioration caused by severe load attacks. The dependency of the deterioration magnitude on the load intensity is considered. The Gaussian copula function is employed to help construct the joint distribution of correlated random variables. Semi-analytical methods are developed to assess the structural failure time and the number of significant load events (shocks) to failure. Illustrative examples are presented to demonstrate the applicability of the proposed model in structural reliability analysis. Parametric studies are performed to investigate the role of deterioration-load correlation in structural reliability. - Highlights: • A new resistance deterioration model for aging structures is proposed. • Time-dependent reliability analysis methods incorporating the proposed deterioration model are developed. • Parametric studies are performed to investigate the role of deterioration-load correlation in structural reliability.

  16. Reliability Assessment of Active Distribution System Using Monte Carlo Simulation Method

    Directory of Open Access Journals (Sweden)

    Shaoyun Ge

    2014-01-01

    Full Text Available In this paper we have treated the reliability assessment problem of low and high DG penetration level of active distribution system using the Monte Carlo simulation method. The problem is formulated as a two-case program, the program of low penetration simulation and the program of high penetration simulation. The load shedding strategy and the simulation process were introduced in detail during each FMEA process. Results indicate that the integration of DG can improve the reliability of the system if the system was operated actively.

  17. Stochastic process corrosion growth models for pipeline reliability

    International Nuclear Information System (INIS)

    Bazán, Felipe Alexander Vargas; Beck, André Teófilo

    2013-01-01

    Highlights: •Novel non-linear stochastic process corrosion growth model is proposed. •Corrosion rate modeled as random Poisson pulses. •Time to corrosion initiation and inherent time-variability properly represented. •Continuous corrosion growth histories obtained. •Model is shown to precisely fit actual corrosion data at two time points. -- Abstract: Linear random variable corrosion models are extensively employed in reliability analysis of pipelines. However, linear models grossly neglect well-known characteristics of the corrosion process. Herein, a non-linear model is proposed, where corrosion rate is represented as a Poisson square wave process. The resulting model represents inherent time-variability of corrosion growth, produces continuous growth and leads to mean growth at less-than-one power of time. Different corrosion models are adjusted to the same set of actual corrosion data for two inspections. The proposed non-linear random process corrosion growth model leads to the best fit to the data, while better representing problem physics

  18. Reliability of Volumetry and Perimetry to Assess Knee Volume.

    Science.gov (United States)

    Nunes, Guilherme S; Yamashitafuji, Igor; Wageck, Bruna; Teixeira, Guilherme Garcia; Karloh, Manuela; de Noronha, Marcos

    2016-08-24

    The treatment of edema after a knee injury is usually 1 of the main objectives during rehabilitation. To assess the success of treatment, 2 methods are commonly used in clinical practice: volumetry and perimetry. To investigate the intra- and interassessor reliability of volumetry and perimetry to assess knee volume. Cross-sectional. Laboratory. 45 healthy participants (26 women) with mean age of 22.4 ± 2.8 y. Knee volume was assessed by 3 assessors (A, B, and C) with 3 methods (lower-limb volumetry [LLV], knee volumetry [KV], and knee perimetry [KP]). Assessor A was the most-experienced assessor, and assessor C, the least experienced. LLV and KV were performed with participants in the orthostatic position, while KP was performed with participants in supine. For the interassessor analysis, the ICC2,1 was high (.82) for KV and very high for LLV (.99) and KP (.99). For the intra-assessor analysis, ICC2,1 ranged from moderate to high for KV (.69-.83) and was very high for LLV (.99) and KP (.97-.99). KV, LLV, and KP are reliable methods, both intra- and interassessor, to measure knee volume.

  19. Method for assessing reliability of a network considering probabilistic safety assessment

    International Nuclear Information System (INIS)

    Cepin, M.

    2005-01-01

    A method for assessment of reliability of the network is developed, which uses the features of the fault tree analysis. The method is developed in a way that the increase of the network under consideration does not require significant increase of the model. The method is applied to small examples of network consisting of a small number of nodes and a small number of their connections. The results give the network reliability. They identify equipment, which is to be carefully maintained in order that the network reliability is not reduced, and equipment, which is a candidate for redundancy, as this would improve network reliability significantly. (author)

  20. Assessing high reliability via Bayesian approach and accelerated tests

    International Nuclear Information System (INIS)

    Erto, Pasquale; Giorgio, Massimiliano

    2002-01-01

    Sometimes the assessment of very high reliability levels is difficult for the following main reasons: - the high reliability level of each item makes it impossible to obtain, in a reasonably short time, a sufficient number of failures; - the high cost of the high reliability items to submit to life tests makes it unfeasible to collect enough data for 'classical' statistical analyses. In the above context, this paper presents a Bayesian solution to the problem of estimation of the parameters of the Weibull-inverse power law model, on the basis of a limited number (say six) of life tests, carried out at different stress levels, all higher than the normal one. The over-stressed (i.e. accelerated) tests allow the use of experimental data obtained in a reasonably short time. The Bayesian approach enables one to reduce the required number of failures adding to the failure information the available a priori engineers' knowledge. This engineers' involvement conforms to the most advanced management policy that aims at involving everyone's commitment in order to obtain total quality. A Monte Carlo study of the non-asymptotic properties of the proposed estimators and a comparison with the properties of maximum likelihood estimators closes the work

  1. Reliability assessment of distribution power systems including distributed generations

    International Nuclear Information System (INIS)

    Megdiche, M.

    2004-12-01

    Nowadays, power systems have reached a good level of reliability. Nevertheless, considering the modifications induced by the connections of small independent producers to distribution networks, there's a need to assess the reliability of these new systems. Distribution networks present several functional characteristics, highlighted by the qualitative study of the failures, as dispersed loads at several places, variable topology and some electrotechnical phenomena which must be taken into account to model the events that can occur. The adopted reliability calculations method is Monte Carlo simulations, the probabilistic method most powerful and most flexible to model complex operating of the distribution system. We devoted a first part on the case of a 20 kV feeder to which a cogeneration unit is connected. The method was applied to a software of stochastic Petri nets simulations. Then a second part related to the study of a low voltage power system supplied by dispersed generations. Here, the complexity of the events required to code the method in an environment of programming allowing the use of power system calculations (load flow, short-circuit, load shedding, management of units powers) in order to analyse the system state for each new event. (author)

  2. Seismic reliability assessment methodology for CANDU concrete containment structures

    International Nuclear Information System (INIS)

    Stephens, M.J.; Nessim, M.A.; Hong, H.P.

    1995-05-01

    A study was undertaken to develop a reliability-based methodology for the assessment of existing CANDU concrete containment structures with respect to seismic loading. The focus of the study was on defining appropriate specified values and partial safety factors for earthquake loading and resistance parameters. Key issues addressed in the work were the identification of an approach to select design earthquake spectra that satisfy consistent safety levels, and the use of structure-specific data in the evaluation of structural resistance. (author). 23 refs., 9 tabs., 15 figs

  3. Complex method to calculate objective assessments of information systems protection to improve expert assessments reliability

    Science.gov (United States)

    Abdenov, A. Zh; Trushin, V. A.; Abdenova, G. A.

    2018-01-01

    The paper considers the questions of filling the relevant SIEM nodes based on calculations of objective assessments in order to improve the reliability of subjective expert assessments. The proposed methodology is necessary for the most accurate security risk assessment of information systems. This technique is also intended for the purpose of establishing real-time operational information protection in the enterprise information systems. Risk calculations are based on objective estimates of the adverse events implementation probabilities, predictions of the damage magnitude from information security violations. Calculations of objective assessments are necessary to increase the reliability of the proposed expert assessments.

  4. Use of reliability engineering tools in safety and risk assessment of nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Raso, Amanda Laureano; Vasconcelos, Vanderley de; Marques, Raíssa Oliveira; Soares, Wellington Antonio; Mesquita, Amir Zacarias, E-mail: amandaraso@hotmail.com, E-mail: vasconv@cdtn.br, E-mail: raissaomarques@gmail.com, E-mail: soaresw@cdtn.br, E-mail: amir@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Serviço de Tecnologia de Reatores

    2017-07-01

    Safety, reliability and availability are fundamental criteria in design, construction and operation of nuclear facilities, as nuclear power plants. Deterministic and probabilistic risk assessments of such facilities are required by regulatory authorities in order to meet licensing regulations, contributing to assure safety, as well as reduce costs and environmental impacts. Probabilistic Risk Assessment has become an important part of licensing requirements of the nuclear power plants in Brazil and in the world. Risk can be defined as a qualitative and/or quantitative assessment of accident sequence frequencies (or probabilities) and their consequences. Risk management is a systematic application of management policies, procedures and practices to identify, analyze, plan, implement, control, communicate and document risks. Several tools and computer codes must be combined, in order to estimate both probabilities and consequences of accidents. Event Tree Analysis (ETA), Fault Tree Analysis (FTA), Reliability Block Diagrams (RBD), and Markov models are examples of evaluation tools that can support the safety and risk assessment for analyzing process systems, identifying potential accidents, and estimating consequences. Because of complexity of such analyzes, specialized computer codes are required, such as the reliability engineering software develop by Reliasoft® Corporation. BlockSim (FTA, RBD and Markov models), RENO (ETA and consequence assessment), Weibull++ (life data and uncertainty analysis), and Xfmea (qualitative risk assessment) are some codes that can be highlighted. This work describes an integrated approach using these tools and software to carry out reliability, safety, and risk assessment of nuclear facilities, as well as, and application example. (author)

  5. Use of reliability engineering tools in safety and risk assessment of nuclear facilities

    International Nuclear Information System (INIS)

    Raso, Amanda Laureano; Vasconcelos, Vanderley de; Marques, Raíssa Oliveira; Soares, Wellington Antonio; Mesquita, Amir Zacarias

    2017-01-01

    Safety, reliability and availability are fundamental criteria in design, construction and operation of nuclear facilities, as nuclear power plants. Deterministic and probabilistic risk assessments of such facilities are required by regulatory authorities in order to meet licensing regulations, contributing to assure safety, as well as reduce costs and environmental impacts. Probabilistic Risk Assessment has become an important part of licensing requirements of the nuclear power plants in Brazil and in the world. Risk can be defined as a qualitative and/or quantitative assessment of accident sequence frequencies (or probabilities) and their consequences. Risk management is a systematic application of management policies, procedures and practices to identify, analyze, plan, implement, control, communicate and document risks. Several tools and computer codes must be combined, in order to estimate both probabilities and consequences of accidents. Event Tree Analysis (ETA), Fault Tree Analysis (FTA), Reliability Block Diagrams (RBD), and Markov models are examples of evaluation tools that can support the safety and risk assessment for analyzing process systems, identifying potential accidents, and estimating consequences. Because of complexity of such analyzes, specialized computer codes are required, such as the reliability engineering software develop by Reliasoft® Corporation. BlockSim (FTA, RBD and Markov models), RENO (ETA and consequence assessment), Weibull++ (life data and uncertainty analysis), and Xfmea (qualitative risk assessment) are some codes that can be highlighted. This work describes an integrated approach using these tools and software to carry out reliability, safety, and risk assessment of nuclear facilities, as well as, and application example. (author)

  6. Reliable scar scoring system to assess photographs of burn patients.

    Science.gov (United States)

    Mecott, Gabriel A; Finnerty, Celeste C; Herndon, David N; Al-Mousawi, Ahmed M; Branski, Ludwik K; Hegde, Sachin; Kraft, Robert; Williams, Felicia N; Maldonado, Susana A; Rivero, Haidy G; Rodriguez-Escobar, Noe; Jeschke, Marc G

    2015-12-01

    Several scar-scoring scales exist to clinically monitor burn scar development and maturation. Although scoring scars through direct clinical examination is ideal, scars must sometimes be scored from photographs. No scar scale currently exists for the latter purpose. We modified a previously described scar scale (Yeong et al., J Burn Care Rehabil 1997) and tested the reliability of this new scale in assessing burn scars from photographs. The new scale consisted of three parameters as follows: scar height, surface appearance, and color mismatch. Each parameter was assigned a score of 1 (best) to 4 (worst), generating a total score of 3-12. Five physicians with burns training scored 120 representative photographs using the original and modified scales. Reliability was analyzed using coefficient of agreement, Cronbach alpha, intraclass correlation coefficient, variance, and coefficient of variance. Analysis of variance was performed using the Kruskal-Wallis test. Color mismatch and scar height scores were validated by analyzing actual height and color differences. The intraclass correlation coefficient, the coefficient of agreement, and Cronbach alpha were higher for the modified scale than those of the original scale. The original scale produced more variance than that in the modified scale. Subanalysis demonstrated that, for all categories, the modified scale had greater correlation and reliability than the original scale. The correlation between color mismatch scores and actual color differences was 0.84 and between scar height scores and actual height was 0.81. The modified scar scale is a simple, reliable, and useful scale for evaluating photographs of burn patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Reliability Assessment and Reliability-Based Inspection and Maintenance of Offshore Wind Turbines

    DEFF Research Database (Denmark)

    Ramirez, José Rangel

    actions are the most relevant and effective means of control of deterioration. The risk-based inspection planning methodology, based on Bayesian decision theory, represents an important tool to identify the suitable strategy to inspect and control the deterioration in structures such as offshore wind...... performance during the life cycle. The deterioration processes, such as fatigue and corrosion, are typically affecting offshore structural systems. This damage decreases the system performance and increases the risk of failure, thus not fulfilling the established safety criteria. Inspection and maintenance...... to their offshore location, no pollution risks and low human risks since they are unmanned. This allows the allocation of lower reliability level compared to e.g. oil & gas installations. With the incursion to water depths between 20 and 50 meters, the use of jacket and tripod structures represents a feasible...

  8. Feasibility and reliability of frailty assessment in the critically ill: a systematic review.

    Science.gov (United States)

    Pugh, Richard J; Ellison, Amy; Pye, Kate; Subbe, Christian P; Thorpe, Chris M; Lone, Nazir I; Clegg, Andrew

    2018-02-26

    For healthcare systems, an ageing population poses challenges in the delivery of equitable and effective care. Frailty assessment has the potential to improve care in the intensive care setting, but applying assessment tools in critical illness may be problematic. The aim of this systematic review was to evaluate evidence for the feasibility and reliability of frailty assessment in critical care. Our primary search was conducted in Medline, Medline In-process, EMBASE, CINAHL, PsycINFO, AMED, Cochrane Database of Systematic Reviews, and Web of Science (January 2001 to October 2017). We included observational studies reporting data on feasibility and reliability of frailty assessment in the critical care setting in patients 16 years and older. Feasibility was assessed in terms of timing of evaluation, the background, training and expertise required for assessors, and reliance upon proxy input. Reliability was assessed in terms of inter-rater reliability. Data from 11 study publications are included, representing 8 study cohorts and 7761 patients. Proxy involvement in frailty assessment ranged from 58 to 100%. Feasibility data were not well-reported overall, but the exclusion rate due to lack of proxy availability ranged from 0 to 45%, the highest rate observed where family involvement was mandatory and the assessment tool relatively complex (frailty index, FI). Conventional elements of frailty phenotype (FP) assessment required modification prior to use in two studies. Clinical staff tended to use a simple judgement-based tool, the clinical frailty scale (CFS). Inter-rater reliability was reported in one study using the CFS and although a good level of agreement was observed between clinician assessments, this was a small and single-centre study. Though of unproven reliability in the critically ill, CFS was the tool used most widely by critical care clinical staff. Conventional FP assessment required modification for general application in critical care, and an FI

  9. Application of nonparametric statistics to material strength/reliability assessment

    International Nuclear Information System (INIS)

    Arai, Taketoshi

    1992-01-01

    An advanced material technology requires data base on a wide variety of material behavior which need to be established experimentally. It may often happen that experiments are practically limited in terms of reproducibility or a range of test parameters. Statistical methods can be applied to understanding uncertainties in such a quantitative manner as required from the reliability point of view. Statistical assessment involves determinations of a most probable value and the maximum and/or minimum value as one-sided or two-sided confidence limit. A scatter of test data can be approximated by a theoretical distribution only if the goodness of fit satisfies a test criterion. Alternatively, nonparametric statistics (NPS) or distribution-free statistics can be applied. Mathematical procedures by NPS are well established for dealing with most reliability problems. They handle only order statistics of a sample. Mathematical formulas and some applications to engineering assessments are described. They include confidence limits of median, population coverage of sample, required minimum number of a sample, and confidence limits of fracture probability. These applications demonstrate that a nonparametric statistical estimation is useful in logical decision making in the case a large uncertainty exists. (author)

  10. Mechanical reliability assessment of optical fibres in Radiation environments

    International Nuclear Information System (INIS)

    Van Uffelen, M.

    2006-01-01

    After more than two decades of intensive research and even some pioneering applications in space, optical fibres are now finding their way in various radiation environments, including both fission and future fusion nuclear-power plants, and high-energy physics experiments. For example, next to distributed monitoring applications of large nuclear infrastructures, fibre-optics can also be used for data communications during maintenance operations in the reactor vessel of the future ITER (International Thermonuclear Experimental Reactor), or for plasma diagnostics applications during operation of the reactor. These maintenance and diagnostics tasks require the optical fibres to withstand extremely high doses of radiation, up to MGy dose levels and temperatures above 150 degrees Celsius. The reliability assessment of fibre-optic systems for their qualification in nuclear environments often requires to meet stringent radiation tolerance levels. The majority of (usually accelerated) radiation assessments have so far focused on optical properties, such as wavelength-dependent radiation induced attenuation and radio-luminescence. The relation of these radiation effects with the fabrication methods and other environmental parameters has been the subject of years of research. Only a few results are available on the long-term evolution of mechanical properties of irradiated optical fibres. As a first step towards understanding the long-term reliability of fibre-optic composite cables in hostile radiation environments, we therefore performed dynamic fatigue tests with different commercial-grade optical fibres, both multi-mode and single-mode types

  11. Reliabilities of mental rotation tasks: limits to the assessment of individual differences.

    Science.gov (United States)

    Hirschfeld, Gerrit; Thielsch, Meinald T; Zernikow, Boris

    2013-01-01

    Mental rotation tasks with objects and body parts as targets are widely used in cognitive neuropsychology. Even though these tasks are well established to study between-groups differences, the reliability on an individual level is largely unknown. We present a systematic study on the internal consistency and test-retest reliability of individual differences in mental rotation tasks comparing different target types and orders of presentations. In total n = 99 participants (n = 63 for the retest) completed the mental rotation tasks with hands, feet, faces, and cars as targets. Different target types were presented in either randomly mixed blocks or blocks of homogeneous targets. Across all target types, the consistency (split-half reliability) and stability (test-retest reliabilities) were good or acceptable both for intercepts and slopes. At the level of individual targets, only intercepts showed acceptable reliabilities. Blocked presentations resulted in significantly faster and numerically more consistent and stable responses. Mental rotation tasks-especially in blocked variants-can be used to reliably assess individual differences in global processing speed. However, the assessment of the theoretically important slope parameter for individual targets requires further adaptations to mental rotation tests.

  12. Reliability assessment using degradation models: bayesian and classical approaches

    Directory of Open Access Journals (Sweden)

    Marta Afonso Freitas

    2010-04-01

    Full Text Available Traditionally, reliability assessment of devices has been based on (accelerated life tests. However, for highly reliable products, little information about reliability is provided by life tests in which few or no failures are typically observed. Since most failures arise from a degradation mechanism at work for which there are characteristics that degrade over time, one alternative is monitor the device for a period of time and assess its reliability from the changes in performance (degradation observed during that period. The goal of this article is to illustrate how degradation data can be modeled and analyzed by using "classical" and Bayesian approaches. Four methods of data analysis based on classical inference are presented. Next we show how Bayesian methods can also be used to provide a natural approach to analyzing degradation data. The approaches are applied to a real data set regarding train wheels degradation.Tradicionalmente, o acesso à confiabilidade de dispositivos tem sido baseado em testes de vida (acelerados. Entretanto, para produtos altamente confiáveis, pouca informação a respeito de sua confiabilidade é fornecida por testes de vida no quais poucas ou nenhumas falhas são observadas. Uma vez que boa parte das falhas é induzida por mecanismos de degradação, uma alternativa é monitorar o dispositivo por um período de tempo e acessar sua confiabilidade através das mudanças em desempenho (degradação observadas durante aquele período. O objetivo deste artigo é ilustrar como dados de degradação podem ser modelados e analisados utilizando-se abordagens "clássicas" e Bayesiana. Quatro métodos de análise de dados baseados em inferência clássica são apresentados. A seguir, mostramos como os métodos Bayesianos podem também ser aplicados para proporcionar uma abordagem natural à análise de dados de degradação. As abordagens são aplicadas a um banco de dados real relacionado à degradação de rodas de trens.

  13. Reliability assessment of competing risks with generalized mixed shock models

    International Nuclear Information System (INIS)

    Rafiee, Koosha; Feng, Qianmei; Coit, David W.

    2017-01-01

    This paper investigates reliability modeling for systems subject to dependent competing risks considering the impact from a new generalized mixed shock model. Two dependent competing risks are soft failure due to a degradation process, and hard failure due to random shocks. The shock process contains fatal shocks that can cause hard failure instantaneously, and nonfatal shocks that impact the system in three different ways: 1) damaging the unit by immediately increasing the degradation level, 2) speeding up the deterioration by accelerating the degradation rate, and 3) weakening the unit strength by reducing the hard failure threshold. While the first impact from nonfatal shocks comes from each individual shock, the other two impacts are realized when the condition for a new generalized mixed shock model is satisfied. Unlike most existing mixed shock models that consider a combination of two shock patterns, our new generalized mixed shock model includes three classic shock patterns. According to the proposed generalized mixed shock model, the degradation rate and the hard failure threshold can simultaneously shift multiple times, whenever the condition for one of these three shock patterns is satisfied. An example using micro-electro-mechanical systems devices illustrates the effectiveness of the proposed approach with sensitivity analysis. - Highlights: • A rich reliability model for systems subject to dependent failures is proposed. • The degradation rate and the hard failure threshold can shift simultaneously. • The shift is triggered by a new generalized mixed shock model. • The shift can occur multiple times under the generalized mixed shock model.

  14. Software reliability evaluation of digital plant protection system development process using V and V

    International Nuclear Information System (INIS)

    Lee, Na Young; Hwang, Il Soon; Seong, Seung Hwan; Oh, Seung Rok

    2001-01-01

    In the nuclear power industry, digital technology has been introduced recently for the Instrumentation and Control (I and C) of reactor systems. For its application to the safety critical system such as Reactor Protection System(RPS), a reliability assessment is indispensable. Unlike traditional reliability models, software reliability is hard to evaluate, and should be evaluated throughout development lifecycle. In the development process of Digital Plant Protection System(DPPS), the concept of verification and validation (V and V) was introduced to assure the quality of the product. Also, test should be performed to assure the reliability. Verification procedure with model checking is relatively well defined, however, test is labor intensive and not well organized. In this paper, we developed the methodological process of combining the verification with validation test case generation. For this, we used PVS for the table specification and for the theorem proving. As a result, we could not only save time to design test case but also get more effective and complete verification related test case set. Add to this, we could extract some meaningful factors useful for the reliability evaluation both from the V and V and verification combined tests

  15. Reliability worth assessment of radial systems with distributed generation

    OpenAIRE

    Bellart Llavall, Francesc Xavier

    2010-01-01

    With recent advances in technology, utilities generation (DG) on the distribution systems. Reliability worth is very important in power system planning and operation. Having a DG ensures reli increase the reliability worth. This research project presents the study of a radial distribution system and the impact of placing DG in order to increase the reliability worth. where a DG have to be placed. The reliability improvement is measured by different reliability indices tha...

  16. The reliability analysis of cutting tools in the HSM processes

    OpenAIRE

    W.S. Lin

    2008-01-01

    Purpose: This article mainly describe the reliability of the cutting tools in the high speed turning by normaldistribution model.Design/methodology/approach: A series of experimental tests have been done to evaluate the reliabilityvariation of the cutting tools. From experimental results, the tool wear distribution and the tool life are determined,and the tool life distribution and the reliability function of cutting tools are derived. Further, the reliability ofcutting tools at anytime for h...

  17. Assessment of microelectronics packaging for high temperature, high reliability applications

    Energy Technology Data Exchange (ETDEWEB)

    Uribe, F.

    1997-04-01

    This report details characterization and development activities in electronic packaging for high temperature applications. This project was conducted through a Department of Energy sponsored Cooperative Research and Development Agreement between Sandia National Laboratories and General Motors. Even though the target application of this collaborative effort is an automotive electronic throttle control system which would be located in the engine compartment, results of this work are directly applicable to Sandia`s national security mission. The component count associated with the throttle control dictates the use of high density packaging not offered by conventional surface mount. An enabling packaging technology was selected and thermal models defined which characterized the thermal and mechanical response of the throttle control module. These models were used to optimize thick film multichip module design, characterize the thermal signatures of the electronic components inside the module, and to determine the temperature field and resulting thermal stresses under conditions that may be encountered during the operational life of the throttle control module. Because the need to use unpackaged devices limits the level of testing that can be performed either at the wafer level or as individual dice, an approach to assure a high level of reliability of the unpackaged components was formulated. Component assembly and interconnect technologies were also evaluated and characterized for high temperature applications. Electrical, mechanical and chemical characterizations of enabling die and component attach technologies were performed. Additionally, studies were conducted to assess the performance and reliability of gold and aluminum wire bonding to thick film conductor inks. Kinetic models were developed and validated to estimate wire bond reliability.

  18. Reliability of a semi-quantitative method for dermal exposure assessment (DREAM)

    NARCIS (Netherlands)

    Wendel de Joode, B. van; Hemmen, J.J. van; Meijster, T.; Major, V.; London, L.; Kromhout, H.

    2005-01-01

    Valid and reliable semi-quantitative dermal exposure assessment methods for epidemiological research and for occupational hygiene practice, applicable for different chemical agents, are practically nonexistent. The aim of this study was to assess the reliability of a recently developed

  19. Probabilistic risk assessment course documentation. Volume 3. System reliability and analysis techniques, Session A - reliability

    International Nuclear Information System (INIS)

    Lofgren, E.V.

    1985-08-01

    This course in System Reliability and Analysis Techniques focuses on the quantitative estimation of reliability at the systems level. Various methods are reviewed, but the structure provided by the fault tree method is used as the basis for system reliability estimates. The principles of fault tree analysis are briefly reviewed. Contributors to system unreliability and unavailability are reviewed, models are given for quantitative evaluation, and the requirements for both generic and plant-specific data are discussed. Also covered are issues of quantifying component faults that relate to the systems context in which the components are embedded. All reliability terms are carefully defined. 44 figs., 22 tabs

  20. Modified Tuck Jump Assessment: Reliability and Training of Raters

    Directory of Open Access Journals (Sweden)

    Craig A. Smith, Nicole J. Chimera, Monica R. Lininger, Meghan Warren

    2017-09-01

    Full Text Available We are writing with regard to “Intra- and inter-rater reliability of the modified tuck jump assessment,” by Fort-Vanmeerhaeghe et al. (2017 published in the Journal of Sports Science & Medicine. The authors reported on the reliability of the modified Tuck Jump Assessment (TJA. The purpose of the article was twofold: to introduce a new scoring methodology and to report on the interrater and intrarater reliability. The authors found the modified TJA to have excellent interrater reliability (ICC = 0.94, 95% CI = 0.88-0.97 and intrarater reliability (rater 1 ICC = 0.94, 95% CI = 0.88-0.9; rater 2 ICC = 0.96, 95% CI = 0.92-0.98 with experienced raters (n = 2 in a sample of 24 elite volleyball athletes. Overall, we found the study to be well conducted and valuable to the field of injury screening; however, the study did not adequately explain how the raters were trained in the modified TJA to improve consistency of scoring, or the modifications of the individual flaw “excessive contact noise at landing.” This information is necessary to improve the clinical utility of the TJA and direct future reliability studies. The TJA has been changed at least three times in the literature: from the initial introduction (Myer et al., 2006 to the most referenced and detailed protocol (Myer et al., 2011 to the publication under discussion (Fort-Vanmeerhaeghe et al., 2017. The initial test protocol was based upon clinical expertise and has evolved over time as new research emerged and problems arose with the original TJA. Initially, the TJA was scored on a visual analog scale (Myer et al., 2006, changed to a dichotomous scale (0 for no flaw or 1 for flaw present (Myer et al., 2011 and most recently modified using an ordinal scale (Fort-Vanmeerhaeghe et al., 2017. A significant disparity in the reported interrater and intrarater reliability arose with the dichotomously scored TJA, between those involved in the development of the TJA (Herrington et al., 2013

  1. Processes and Procedures for Estimating Score Reliability and Precision

    Science.gov (United States)

    Bardhoshi, Gerta; Erford, Bradley T.

    2017-01-01

    Precision is a key facet of test development, with score reliability determined primarily according to the types of error one wants to approximate and demonstrate. This article identifies and discusses several primary forms of reliability estimation: internal consistency (i.e., split-half, KR-20, a), test-retest, alternate forms, interscorer, and…

  2. Analysis of dependent failures in risk assessment and reliability evaluation

    International Nuclear Information System (INIS)

    Fleming, K.N.; Mosleh, A.; Kelley, A.P. Jr.; Gas-Cooled Reactors Associates, La Jolla, CA)

    1983-01-01

    The ability to estimate the risk of potential reactor accidents is largely determined by the ability to analyze statistically dependent multiple failures. The importance of dependent failures has been indicated in recent probabilistic risk assessment (PRA) studies as well as in reports of reactor operating experiences. This article highlights the importance of several different types of dependent failures from the perspective of the risk and reliability analyst and provides references to the methods and data available for their analysis. In addition to describing the current state of the art, some recent advances, pitfalls, misconceptions, and limitations of some approaches to dependent failure analysis are addressed. A summary is included of the discourse on this subject, which is presented in the Institute of Electrical and Electronics Engineers/American Nuclear Society PRA Procedures Guide

  3. Quantification of human reliability in probabilistic safety assessment

    International Nuclear Information System (INIS)

    Hirschberg, S.; Dankg, Vinh N.

    1996-01-01

    Human performance may substantially influence the reliability and safety of complex technical systems. For this reason, Human Reliability Analysis (HRA) constitutes an important part of Probabilistic Safety Assessment (PSAs) or Quantitative Risk Analyses (QRAs). The results of these studies as well as analyses of past accidents and incidents clearly demonstrate the importance of human interactions. The contribution of human errors to the core damage frequency (CDF), as estimated in the Swedish nuclear PSAs, are between 15 and 88%. A survey of the FRAs in the Swiss PSAs shows that also for the Swiss nuclear power plants the estimated HE contributions are substantial (49% of the CDF due to internal events in the case of Beznau and 70% in the case of Muehleberg; for the total CDF, including external events, 25% respectively 20%). Similar results can be extracted from the PSAs carried out for French, German, and US plants. In PSAs or QRAs, the adequate treatment of the human interactions with the system is a key to the understanding of accident sequences and their relative importance to overall risk. The main objectives of HRA are: first, to ensure that the key human interactions are systematically identified and incorporated into the safety analysis in a traceable manner, and second, to quantify the probabilities of their success and failure. Adopting a structured and systematic approach to the assessment of human performance makes it possible to provide greater confidence that the safety and availability of human-machine systems is not unduly jeopardized by human performance problems. Section 2 discusses the different types of human interactions analysed in PSAs. More generally, the section presents how HRA fits in the overall safety analysis, that is, how the human interactions to be quantified are identified. Section 3 addresses the methods for quantification. Section 4 concludes the paper by presenting some recommendations and pointing out the limitations of the

  4. Assessment of Data Reliability of Wireless Sensor Network for Bioinformatics

    Directory of Open Access Journals (Sweden)

    Ting Dong

    2017-09-01

    Full Text Available As a focal point of biotechnology, bioinformatics integrates knowledge from biology, mathematics, physics, chemistry, computer science and information science. It generally deals with genome informatics, protein structure and drug design. However, the data or information thus acquired from the main areas of bioinformatics may not be effective. Some researchers combined bioinformatics with wireless sensor network (WSN into biosensor and other tools, and applied them to such areas as fermentation, environmental monitoring, food engineering, clinical medicine and military. In the combination, the WSN is used to collect data and information. The reliability of the WSN in bioinformatics is the prerequisite to effective utilization of information. It is greatly influenced by factors like quality, benefits, service, timeliness and stability, some of them are qualitative and some are quantitative. Hence, it is necessary to develop a method that can handle both qualitative and quantitative assessment of information. A viable option is the fuzzy linguistic method, especially 2-tuple linguistic model, which has been extensively used to cope with such issues. As a result, this paper introduces 2-tuple linguistic representation to assist experts in giving their opinions on different WSNs in bioinformatics that involve multiple factors. Moreover, the author proposes a novel way to determine attribute weights and uses the method to weigh the relative importance of different influencing factors which can be considered as attributes in the assessment of the WSN in bioinformatics. Finally, an illustrative example is given to provide a reasonable solution for the assessment.

  5. Reliability algorithms applied to reinforced concrete structures durability assessment

    Directory of Open Access Journals (Sweden)

    C. G. Nogueira

    Full Text Available This paper addresses the analysis of probabilistic corrosion time initiation in reinforced concrete structures exposed to ions chloride penetration. Structural durability is an important criterion which must be evaluated in every type of structure, especially when these structures are constructed in aggressive atmospheres. Considering reinforced concrete members, chloride diffusion process is widely used to evaluate the durability. Therefore, at modelling this phenomenon, corrosion of reinforcements can be better estimated and prevented. These processes begin when a threshold level of chlorides concentration is reached at the steel bars of reinforcements. Despite the robustness of several models proposed in the literature, deterministic approaches fail to predict accurately the corrosion time initiation due to the inherently randomness observed in this process. In this regard, the durability can be more realistically represented using probabilistic approaches. A probabilistic analysis of ions chloride penetration is presented in this paper. The ions chloride penetration is simulated using the Fick's second law of diffusion. This law represents the chloride diffusion process, considering time dependent effects. The probability of failure is calculated using Monte Carlo simulation and the First Order Reliability Method (FORM with a direct coupling approach. Some examples are considered in order to study these phenomena and a simplified method is proposed to determine optimal values for concrete cover.

  6. Impact of data source on travel time reliability assessment.

    Science.gov (United States)

    2014-08-01

    Travel time reliability measures are becoming an increasingly important input to the mobility and : congestion management studies. In the case of Maryland State Highway Administration, reliability : measures are key elements in the agencys Annual ...

  7. Portfolio assessment during medical internships: How to obtain a reliable and feasible assessment procedure?

    Science.gov (United States)

    Michels, Nele R M; Driessen, Erik W; Muijtjens, Arno M M; Van Gaal, Luc F; Bossaert, Leo L; De Winter, Benedicte Y

    2009-12-01

    A portfolio is used to mentor and assess students' clinical performance at the workplace. However, students and raters often perceive the portfolio as a time-consuming instrument. In this study, we investigated whether assessment during medical internship by a portfolio can combine reliability and feasibility. The domain-oriented reliability of 61 double-rated portfolios was measured, using a generalisability analysis with portfolio tasks and raters as sources of variation in measuring the performance of a student. We obtained reliability (Phi coefficient) of 0.87 with this internship portfolio containing 15 double-rated tasks. The generalisability analysis showed that an acceptable level of reliability (Phi = 0.80) was maintained when the amount of portfolio tasks was decreased to 13 or 9 using one and two raters, respectively. Our study shows that a portfolio can be a reliable method for the assessment of workplace learning. The possibility of reducing the amount of tasks or raters while maintaining a sufficient level of reliability suggests an increase in feasibility of portfolio use for both students and raters.

  8. Dynamic reliability assessment and prediction for repairable systems with interval-censored data

    International Nuclear Information System (INIS)

    Peng, Yizhen; Wang, Yu; Zi, YanYang; Tsui, Kwok-Leung; Zhang, Chuhua

    2017-01-01

    The ‘Test, Analyze and Fix’ process is widely applied to improve the reliability of a repairable system. In this process, dynamic reliability assessment for the system has been paid a great deal of attention. Due to instrument malfunctions, staff omissions and imperfect inspection strategies, field reliability data are often subject to interval censoring, making dynamic reliability assessment become a difficult task. Most traditional methods assume this kind of data as multiple normal distributed variables or the missing mechanism as missing at random, which may cause a large bias in parameter estimation. This paper proposes a novel method to evaluate and predict the dynamic reliability of a repairable system subject to interval-censored problem. First, a multiple imputation strategy based on the assumption that the reliability growth trend follows a nonhomogeneous Poisson process is developed to derive the distributions of missing data. Second, a new order statistic model that can transfer the dependent variables into independent variables is developed to simplify the imputation procedure. The unknown parameters of the model are iteratively inferred by the Monte Carlo expectation maximization (MCEM) algorithm. Finally, to verify the effectiveness of the proposed method, a simulation and a real case study for gas pipeline compressor system are implemented. - Highlights: • A new multiple imputation strategy was developed to derive the PDF of missing data. • A new order statistic model was developed to simplify the imputation procedure. • The parameters of the order statistic model were iteratively inferred by MCEM. • A real cases study was conducted to verify the effectiveness of the proposed method.

  9. Reliability engineering

    International Nuclear Information System (INIS)

    Lee, Chi Woo; Kim, Sun Jin; Lee, Seung Woo; Jeong, Sang Yeong

    1993-08-01

    This book start what is reliability? such as origin of reliability problems, definition of reliability and reliability and use of reliability. It also deals with probability and calculation of reliability, reliability function and failure rate, probability distribution of reliability, assumption of MTBF, process of probability distribution, down time, maintainability and availability, break down maintenance and preventive maintenance design of reliability, design of reliability for prediction and statistics, reliability test, reliability data and design and management of reliability.

  10. Modeling Parameters of Reliability of Technological Processes of Hydrocarbon Pipeline Transportation

    Directory of Open Access Journals (Sweden)

    Shalay Viktor

    2016-01-01

    Full Text Available On the basis of methods of system analysis and parametric reliability theory, the mathematical modeling of processes of oil and gas equipment operation in reliability monitoring was conducted according to dispatching data. To check the quality of empiric distribution coordination , an algorithm and mathematical methods of analysis are worked out in the on-line mode in a changing operating conditions. An analysis of physical cause-and-effect relations mechanism between the key factors and changing parameters of technical systems of oil and gas facilities is made, the basic types of technical distribution parameters are defined. Evaluation of the adequacy the analyzed parameters of the type of distribution is provided by using a criterion A.Kolmogorov, as the most universal, accurate and adequate to verify the distribution of continuous processes of complex multiple-technical systems. Methods of calculation are provided for supervising by independent bodies for risk assessment and safety facilities.

  11. Accuracy and Reliability of Peer Assessment of Athletic Training Psychomotor Laboratory Skills

    Science.gov (United States)

    Marty, Melissa C.; Henning, Jolene M.; Willse, John T.

    2010-01-01

    less reliable than having more than 1 student assess those skills on more than 1 occasion. Peer assessment of psychomotor skills could be an important part of the learning process and a tool to supplement instructor assessment. PMID:21062185

  12. Accuracy and reliability of peer assessment of athletic training psychomotor laboratory skills.

    Science.gov (United States)

    Marty, Melissa C; Henning, Jolene M; Willse, John T

    2010-01-01

    Peer assessment is defined as students judging the level or quality of a fellow student's understanding. No researchers have yet demonstrated the accuracy or reliability of peer assessment in athletic training education. To determine the accuracy and reliability of peer assessment of athletic training students' psychomotor skills. Cross-sectional study. Entry-level master's athletic training education program. First-year (n  =  5) and second-year (n  =  8) students. Participants evaluated 10 videos of a peer performing 3 psychomotor skills (middle deltoid manual muscle test, Faber test, and Slocum drawer test) on 2 separate occasions using a valid assessment tool. Accuracy of each peer-assessment score was examined through percentage correct scores. We used a generalizability study to determine how reliable athletic training students were in assessing a peer performing the aforementioned skills. Decision studies using generalizability theory demonstrated how the peer-assessment scores were affected by the number of participants and number of occasions. Participants had a high percentage of correct scores: 96.84% for the middle deltoid manual muscle test, 94.83% for the Faber test, and 97.13% for the Slocum drawer test. They were not able to reliably assess a peer performing any of the psychomotor skills on only 1 occasion. However, the φ increased (exceeding the 0.70 minimal standard) when 2 participants assessed the skill on 3 occasions (φ  =  0.79) for the Faber test, with 1 participant on 2 occasions (φ  =  0.76) for the Slocum drawer test, and with 3 participants on 2 occasions for the middle deltoid manual muscle test (φ  =  0.72). Although students did not detect all errors, they assessed their peers with an average of 96% accuracy. Having only 1 student assess a peer performing certain psychomotor skills was less reliable than having more than 1 student assess those skills on more than 1 occasion. Peer assessment of psychomotor skills

  13. Reliability of a single objective measure in assessing sleepiness.

    Science.gov (United States)

    Sunwoo, Bernie Y; Jackson, Nicholas; Maislin, Greg; Gurubhagavatula, Indira; George, Charles F; Pack, Allan I

    2012-01-01

    To evaluate reliability of single objective tests in assessing sleepiness. Subjects who completed polysomnography underwent a 4-nap multiple sleep latency test (MSLT) the following day. Prior to each nap opportunity on MSLT, subjects performed the psychomotor vigilance test (PVT) and divided attention driving task (DADT). Results of single versus multiple test administrations were compared using the intraclass correlation coefficient (ICC) and adjusted for test administration order effects to explore time of day effects. Measures were explored as continuous and binary (i.e., impaired or not impaired). Community-based sample evaluated at a tertiary, university-based sleep center. 372 adult commercial vehicle operators oversampled for increased obstructive sleep apnea risk. N/A. AS CONTINUOUS MEASURES, ICC WERE AS FOLLOWS: MSLT 0.45, PVT median response time 0.69, PVT number of lapses 0.51, 10-min DADT tracking error 0.87, 20-min DADT tracking error 0.90. Based on binary outcomes, ICC were: MSLT 0.63, PVT number of lapses 0.85, 10-min DADT 0.95, 20-min DADT 0.96. Statistically significant time of day effects were seen in both the MSLT and PVT but not the DADT. Correlation between ESS and different objective tests was strongest for MSLT, range [-0.270 to -0.195] and persisted across all time points. Single DADT and PVT administrations are reliable measures of sleepiness. A single MSLT administration can reasonably discriminate individuals with MSL < 8 minutes. These results support the use of a single administration of some objective tests of sleepiness when performed under controlled conditions in routine clinical care.

  14. An objective spinal motion imaging assessment (OSMIA): reliability, accuracy and exposure data.

    OpenAIRE

    Breen, Alan C.; Muggleton, J.M.; Mellor, F.E.

    2006-01-01

    Abstract Background Minimally-invasive measurement of continuous inter-vertebral motion in clinical settings is difficult to achieve. This paper describes the reliability, validity and radiation exposure levels in a new Objective Spinal Motion Imaging Assessment system (OSMIA) based on low-dose fluoroscopy and image processing. Methods Fluoroscopic sequences in coronal and sagittal planes were obtained from 2 calibration models using dry lumbar vertebrae, plus the lumbar spines of 30 asymptom...

  15. Reliability assessment of restructured power systems using reliability network equivalent and pseudo-sequential simulation techniques

    International Nuclear Information System (INIS)

    Ding, Yi; Wang, Peng; Goel, Lalit; Billinton, Roy; Karki, Rajesh

    2007-01-01

    This paper presents a technique to evaluate reliability of a restructured power system with a bilateral market. The proposed technique is based on the combination of the reliability network equivalent and pseudo-sequential simulation approaches. The reliability network equivalent techniques have been implemented in the Monte Carlo simulation procedure to reduce the computational burden of the analysis. Pseudo-sequential simulation has been used to increase the computational efficiency of the non-sequential simulation method and to model the chronological aspects of market trading and system operation. Multi-state Markov models for generation and transmission systems are proposed and implemented in the simulation. A new load shedding scheme is proposed during generation inadequacy and network congestion to minimize the load curtailment. The IEEE reliability test system (RTS) is used to illustrate the technique. (author)

  16. ITSM process assessment supporting ITIL

    CERN Document Server

    Barafort, Béatrix; Cortina, Stéphane

    2009-01-01

    The key to any successful IT Service Management solution are strong, clear processes that are fit for purpose. The continual cycle of service improvements must therefore look at the existing processes and assess how effective they are within changing business requirements.This innovative title not only looks at this fundamental process assessment, it does it using the key ISO/IEC standard in this area. In brief, this title explains the meeting between two standards:ITIL: the de facto standard in IT Service Management.ISO/IEC 15504 Information technology - Process assessmentReaders can therefor

  17. Assessment of the nursing care product (APROCENF: a reliability and construct validity study

    Directory of Open Access Journals (Sweden)

    Danielle Fabiana Cucolo

    Full Text Available ABSTRACT Objectives: to verify the reliability and construct validity estimates of the "Assessment of nursing care product" scale (APROCENF and its applicability. Methods: this validation study included a sample of 40 (inter-rater reliability and 172 (construct validity assessments performed by nurses at the end of the work shift at nine inpatient services of a teaching hospital in the Brazilian Southeast. The data were collected between February and September/2014 with interruptions. Cronbach's alpha and Spearman's correlation coefficients were calculated, as well as the intraclass correlation and the weighted kappa index (inter-rater reliability. Exploratory factor analysis was used with principal component extraction and varimax rotation (construct validity. Results: the internal consistency revealed an alpha coefficient of 0.85, item-item correlation ranging between 0.13 and 0.61 and item-total correlation between 0.43 and 0.69. Inter-rater equivalence was obtained and all items evidenced significant factor loadings. Conclusion: this research evidenced the reliability and construct validity of the scale to assess the nursing care product. Its application in nursing practice permits identifying improvements needed in the production process, contributing to management and care decisions.

  18. Reliability analysis of nuclear component cooling water system using semi-Markov process model

    International Nuclear Information System (INIS)

    Veeramany, Arun; Pandey, Mahesh D.

    2011-01-01

    Research highlights: → Semi-Markov process (SMP) model is used to evaluate system failure probability of the nuclear component cooling water (NCCW) system. → SMP is used because it can solve reliability block diagram with a mixture of redundant repairable and non-repairable components. → The primary objective is to demonstrate that SMP can consider Weibull failure time distribution for components while a Markov model cannot → Result: the variability in component failure time is directly proportional to the NCCW system failure probability. → The result can be utilized as an initiating event probability in probabilistic safety assessment projects. - Abstract: A reliability analysis of nuclear component cooling water (NCCW) system is carried out. Semi-Markov process model is used in the analysis because it has potential to solve a reliability block diagram with a mixture of repairable and non-repairable components. With Markov models it is only possible to assume an exponential profile for component failure times. An advantage of the proposed model is the ability to assume Weibull distribution for the failure time of components. In an attempt to reduce the number of states in the model, it is shown that usage of poly-Weibull distribution arises. The objective of the paper is to determine system failure probability under these assumptions. Monte Carlo simulation is used to validate the model result. This result can be utilized as an initiating event probability in probabilistic safety assessment projects.

  19. The process of performance assessment

    International Nuclear Information System (INIS)

    King, C.M.; Halford, D.K.

    1986-01-01

    An introductory review of the subject of ''Performance Assessment'' will be presented. Emphasis will be placed on the process of performance assessment from the standpoint of defining the process. Performance assessment, from evolving experience at DOE sites, has short-term and long-term subprograms, the components of which will be discussed. The role of mathematical modeling in performance assessment will be addressed including the pros and cons of current approaches. Finally, the ''system/site/technology'' issues as the focal point of this symposium will be reviewed

  20. Human Reliability Analysis in Support of Risk Assessment for Positive Train Control

    Science.gov (United States)

    2003-06-01

    This report describes an approach to evaluating the reliability of human actions that are modeled in a probabilistic risk assessment : (PRA) of train control operations. This approach to human reliability analysis (HRA) has been applied in the case o...

  1. Assessment of ALWR passive safety system reliability. Phase 1: Methodology development and component failure quantification

    International Nuclear Information System (INIS)

    Hake, T.M.; Heger, A.S.

    1995-04-01

    Many advanced light water reactor (ALWR) concepts proposed for the next generation of nuclear power plants rely on passive systems to perform safety functions, rather than active systems as in current reactor designs. These passive systems depend to a great extent on physical processes such as natural circulation for their driving force, and not on active components, such as pumps. An NRC-sponsored study was begun at Sandia National Laboratories to develop and implement a methodology for evaluating ALWR passive system reliability in the context of probabilistic risk assessment (PRA). This report documents the first of three phases of this study, including methodology development, system-level qualitative analysis, and sequence-level component failure quantification. The methodology developed addresses both the component (e.g. valve) failure aspect of passive system failure, and uncertainties in system success criteria arising from uncertainties in the system's underlying physical processes. Traditional PRA methods, such as fault and event tree modeling, are applied to the component failure aspect. Thermal-hydraulic calculations are incorporated into a formal expert judgment process to address uncertainties in selected natural processes and success criteria. The first phase of the program has emphasized the component failure element of passive system reliability, rather than the natural process uncertainties. Although cursory evaluation of the natural processes has been performed as part of Phase 1, detailed assessment of these processes will take place during Phases 2 and 3 of the program

  2. Reliability-based Assessment of Fatigue Life for Bridges

    DEFF Research Database (Denmark)

    Toft, Henrik Stensgaard; Sørensen, John Dalsgaard

    2012-01-01

    The reliability level for bridges is discussed based on a comparison of the reliability levels proposed and used by e.g. JCSS, ISO, NKB and Eurocodes. The influence of reserve capacity by which failure of a specific detail does not lead to structural collapse is investigated. The results show...

  3. Construction of Valid and Reliable Test for Assessment of Students

    Science.gov (United States)

    Osadebe, P. U.

    2015-01-01

    The study was carried out to construct a valid and reliable test in Economics for secondary school students. Two research questions were drawn to guide the establishment of validity and reliability for the Economics Achievement Test (EAT). It is a multiple choice objective test of five options with 100 items. A sample of 1000 students was randomly…

  4. Assessment of power reliability and improvement potential by using ...

    African Journals Online (AJOL)

    This paper presents the use of smart reclosers for improving reliability of a distribution system of one of the major cities of Ethiopia. As frequent power interruptions are posing a huge problem to the life of the people and the economy, finding a solution to the problem is very essential. Electric reliability has affected social well ...

  5. Reliability assessment of Indian Point Unit 3 containment structure

    International Nuclear Information System (INIS)

    Kawakami, J.; Hwang, H.; Chang, M.T.; Reich, M.

    1984-01-01

    In the current design criteria, the load combinations specified for design of concrete containment structures are in the deterministic formats. However, by applying the probability-based reliability method developed by BNL to the concrete containment structures designed according to the criteria, it is possible to evaluate the reliability levels implied in the current design criteria. For this purpose, the reliability analysis is applied to the Indian Point Unit No. 3 containment. The details of the containment structure such as the geometries and the rebar arrangements, etc., are taken from the working drawings and the final safety analysis reports. Three kinds of loads are considered in the reliability analysis. They are, dead load (D), accidental pressure due to a large LOCA (P), and earthquake ground acceleration (E). Reliability analysis of the containment subjected to all combinations of loads is performed. Results are presented in this report

  6. Reliability and validity of a brief method to assess nociceptive flexion reflex (NFR) threshold.

    Science.gov (United States)

    Rhudy, Jamie L; France, Christopher R

    2011-07-01

    The nociceptive flexion reflex (NFR) is a physiological tool to study spinal nociception. However, NFR assessment can take several minutes and expose participants to repeated suprathreshold stimulations. The 4 studies reported here assessed the reliability and validity of a brief method to assess NFR threshold that uses a single ascending series of stimulations (Peak 1 NFR), by comparing it to a well-validated method that uses 3 ascending/descending staircases of stimulations (Staircase NFR). Correlations between the NFR definitions were high, were on par with test-retest correlations of Staircase NFR, and were not affected by participant sex or chronic pain status. Results also indicated the test-retest reliabilities for the 2 definitions were similar. Using larger stimulus increments (4 mAs) to assess Peak 1 NFR tended to result in higher NFR threshold estimates than using the Staircase NFR definition, whereas smaller stimulus increments (2 mAs) tended to result in lower NFR threshold estimates than the Staircase NFR definition. Neither NFR definition was correlated with anxiety, pain catastrophizing, or anxiety sensitivity. In sum, a single ascending series of electrical stimulations results in a reliable and valid estimate of NFR threshold. However, caution may be warranted when comparing NFR thresholds across studies that differ in the ascending stimulus increments. This brief method to assess NFR threshold is reliable and valid; therefore, it should be useful to clinical pain researchers interested in quickly assessing inter- and intra-individual differences in spinal nociceptive processes. Copyright © 2011 American Pain Society. Published by Elsevier Inc. All rights reserved.

  7. Reliability Assessment and Reliability-Based Inspection and Maintenance of Offshore Wind Turbines

    DEFF Research Database (Denmark)

    Ramírez, José G. Rangel; Sørensen, John Dalsgaard

    2009-01-01

    Probabilistic methodologies represent an important tool to identify the suitable strategy to inspect and deal with the deterioration in structures such as offshore wind turbines (OWT). Reliability based methods such as Risk Based Inspection (RBI) planning may represent a proper methodology to opt...

  8. Reliability assessment of ballistic jump squats and bench throws.

    Science.gov (United States)

    Alemany, Joseph A; Pandorf, Clay E; Montain, Scott J; Castellani, John W; Tuckow, Alexander P; Nindl, Bradley C

    2005-02-01

    The purpose of this investigation was to determine the test-retest reliability and coefficient of variation of 2 novel physical performance tests. Ten healthy men (22.0 +/- 3.0 years, 87.0 +/- 8.0 kg, 20.0 +/- 5.0% body fat) performed 30 continuous and dynamic jump squats (JS) and bench throws (BT) on 4 separate occasions. The movements were performed under loaded conditions utilizing 30% of subject's predetermined 1 repetition maximum in the back squat and bench press. Mean power (MP; W), peak power (PP; W), mean velocity (MV; m.s(-1)), peak velocity (PV; m.s(-1)), and total work (TW; J) were assessed using a ballistic measurement system (Innervations Inc., Muncie, IN). Data were analyzed using repeated measures analysis of variance with Duncan's post hoc test when mean differences were p < or = 0.05. Intraclass correlation coefficient (ICC) and within-subject coefficient of variation (CV%) were also calculated. All values are presented as mean +/- SE. BT variables were statistically similar across the 4 sessions: MP (350.0 +/- 13.9 W), PP (431.4 +/- 18.5 W) MV (1.6 +/- 0.03 m.s(-1)), PV (2.0 +/- 0.03 m.s(-1)), and TW (199.1 +/- 7.2 J). For JS, session 3 PP (1,669.8 +/- 111.2 W) was significantly greater vs. sessions 1, 2, and 4 (1,601.2 +/- 58.4 W). Session 4 MP (1,403.2 +/- 88.6 W) and MV (1.9 +/- 0.1 m.s(-1)) for JS were significantly lower during sessions 1, 2, and 3 (MP: 1,479.4.5 +/- 44.8 W, MV: 2.0 +/- 0.05 m.s(-1)). TW (834.7 +/- 24.3 J) and PV (2.2 +/- 0.04 m.s(-1)) were statistically similar during all sessions for JS. The CVs ranged from 3.0 to 7.6% for the BT and 3.2 to 5.7% for the JS. ICCs for MP, PP, MV, PV, and TW were 0.92, 0.95, 0.94, 0.91, and 0.95, respectively, during BT. ICCs during JS for MP, PP, MV, PV, and TW were 0.96, 0.98, 0.94, 0.94, and 0.89, respectively. The results of the current study support the use of a 30 continuous and dynamic BT protocol as a reliable upper-body physical performance test, which can be administered with

  9. Nuclear computerized library for assessing reactor reliability (NUCLARR): User's guide: Part 3, NUCLARR system description

    International Nuclear Information System (INIS)

    Gilmore, W.E.; Gentillon, C.D.; Gertman, D.I.; Beers, G.H.; Galyean, W.J.; Gilbert, B.G.

    1988-06-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automated data base management system for processing and storing human error probability and hardware component failure data. The NUCLARR system software resides on an IBM (or compatible) personal micro-computer. NUCLARR can be used by the end user to furnish data inputs for both human and hardware reliability analysis in support of a variety of risk assessment activities. The NUCLARR system is documented in a five-volume series of reports. Volume IV of this series is the User's Guide for operating the NUCLARR software and is presented in three parts. This document, Part 3: NUCLARR System Description, provides an in-depth discussion of the design characteristics and special features of the NUCLARR software. Part 3 also presents the organization of the data base structures and techniques used to manipulate the data

  10. Nuclear computerized library for assessing reactor reliability (NUCLARR): Part 2, Guide to operations: User's guide

    International Nuclear Information System (INIS)

    Gilmore, W.E.; Gentillon, C.D.; Gertman, D.I.; Beers, G.H.; Galyean, W.J.; Gilbert, B.G.

    1988-06-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automated data base management system for processing and storing human error probability and hardware component failure data. The NUCLARR system software resides on an IBM (or compatible) personal micro-computer. NUCLARR can be used by the end user to furnish data inputs for both human and hardware reliability analysis in support of a variety of risk assessment activities. The NUCLARR system is documented in a five-volume series of reports. Volume IV of this series is the User's Guide for operating the NUCLARR software and is presented in three parts. This volume, Part 2: Guide to Operations, contains the instructions and basic procedures for using the NUCLARR software. Part 2 provides guidance and information for getting started, performing the desired functions, and making the most efficient use of the system's features

  11. Human Reliability Assessments: Using the Past (Shuttle) to Predict the Future (Orion)

    Science.gov (United States)

    DeMott, Diana L.; Bigler, Mark A.

    2017-01-01

    NASA (National Aeronautics and Space Administration) Johnson Space Center (JSC) Safety and Mission Assurance (S&MA) uses two human reliability analysis (HRA) methodologies. The first is a simplified method which is based on how much time is available to complete the action, with consideration included for environmental and personal factors that could influence the human's reliability. This method is expected to provide a conservative value or placeholder as a preliminary estimate. This preliminary estimate or screening value is used to determine which placeholder needs a more detailed assessment. The second methodology is used to develop a more detailed human reliability assessment on the performance of critical human actions. This assessment needs to consider more than the time available, this would include factors such as: the importance of the action, the context, environmental factors, potential human stresses, previous experience, training, physical design interfaces, available procedures/checklists and internal human stresses. The more detailed assessment is expected to be more realistic than that based primarily on time available. When performing an HRA on a system or process that has an operational history, we have information specific to the task based on this history and experience. In the case of a Probabilistic Risk Assessment (PRA) that is based on a new design and has no operational history, providing a "reasonable" assessment of potential crew actions becomes more challenging. To determine what is expected of future operational parameters, the experience from individuals who had relevant experience and were familiar with the system and process previously implemented by NASA was used to provide the "best" available data. Personnel from Flight Operations, Flight Directors, Launch Test Directors, Control Room Console Operators, and Astronauts were all interviewed to provide a comprehensive picture of previous NASA operations. Verification of the

  12. LED Lighting System Reliability Modeling and Inference via Random Effects Gamma Process and Copula Function

    Directory of Open Access Journals (Sweden)

    Huibing Hao

    2015-01-01

    Full Text Available Light emitting diode (LED lamp has attracted increasing interest in the field of lighting systems due to its low energy and long lifetime. For different functions (i.e., illumination and color, it may have two or more performance characteristics. When the multiple performance characteristics are dependent, it creates a challenging problem to accurately analyze the system reliability. In this paper, we assume that the system has two performance characteristics, and each performance characteristic is governed by a random effects Gamma process where the random effects can capture the unit to unit differences. The dependency of performance characteristics is described by a Frank copula function. Via the copula function, the reliability assessment model is proposed. Considering the model is so complicated and analytically intractable, the Markov chain Monte Carlo (MCMC method is used to estimate the unknown parameters. A numerical example about actual LED lamps data is given to demonstrate the usefulness and validity of the proposed model and method.

  13. Knowledge modelling and reliability processing: presentation of the Figaro language and associated tools

    International Nuclear Information System (INIS)

    Bouissou, M.; Villatte, N.; Bouhadana, H.; Bannelier, M.

    1991-12-01

    EDF has been developing for several years an integrated set of knowledge-based and algorithmic tools for automation of reliability assessment of complex (especially sequential) systems. In this environment, the reliability expert has at his disposal all the powerful software tools for qualitative and quantitative processing, besides he gets various means to generate automatically the inputs for these tools, through the acquisition of graphical data. The development of these tools has been based on FIGARO, a specific language, which was built to get an homogeneous system modelling. Various compilers and interpreters get a FIGARO model into conventional models, such as fault-trees, Markov chains, Petri Networks. In this report, we introduce the main basics of FIGARO language, illustrating them with examples

  14. Reliability and validity evidence of the Assessment of Language Use in Social Contexts for Adults (ALUSCA).

    Science.gov (United States)

    Valente, Ana Rita S; Hall, Andreia; Alvelos, Helena; Leahy, Margaret; Jesus, Luis M T

    2018-04-12

    The appropriate use of language in context depends on the speaker's pragmatic language competencies. A coding system was used to develop a specific and adult-focused self-administered questionnaire to adults who stutter and adults who do not stutter, The Assessment of Language Use in Social Contexts for Adults, with three categories: precursors, basic exchanges, and extended literal/non-literal discourse. This paper presents the content validity, item analysis, reliability coefficients and evidences of construct validity of the instrument. Content validity analysis was based on a two-stage process: first, 11 pragmatic questionnaires were assessed to identify items that probe each pragmatic competency and to create the first version of the instrument; second, items were assessed qualitatively by an expert panel composed by adults who stutter and controls, and quantitatively and qualitatively by an expert panel composed by clinicians. A pilot study was conducted with five adults who stutter and five controls to analyse items and calculate reliability. Construct validity evidences were obtained using the hypothesized relationships method and factor analysis with 28 adults who stutter and 28 controls. Concerning content validity, the questionnaires assessed up to 13 pragmatic competencies. Qualitative and quantitative analysis revealed ambiguities in items construction. Disagreement between experts was solved through item modification. The pilot study showed that the instrument presented internal consistency and temporal stability. Significant differences between adults who stutter and controls and different response profiles revealed the instrument's underlying construct. The instrument is reliable and presented evidences of construct validity.

  15. Extended block diagram method for a multi-state system reliability assessment

    International Nuclear Information System (INIS)

    Lisnianski, Anatoly

    2007-01-01

    The presented method extends the classical reliability block diagram method to a repairable multi-state system. It is very suitable for engineering applications since the procedure is well formalized and based on the natural decomposition of the entire multi-state system (the system is represented as a collection of its elements). Until now, the classical block diagram method did not provide the reliability assessment for the repairable multi-state system. The straightforward stochastic process methods are very difficult for engineering application in such cases due to the 'dimension damnation'-huge number of system states. The suggested method is based on the combined random processes and the universal generating function technique and drastically reduces the number of states in the multi-state model

  16. Modeling human intention formation for human reliability assessment

    International Nuclear Information System (INIS)

    Woods, D.D.; Roth, E.M.; Pople, H. Jr.

    1988-01-01

    This paper describes a dynamic simulation capability for modeling how people form intentions to act in nuclear power plant emergency situations. This modeling tool, Cognitive Environment Simulation or CES, was developed based on techniques from artificial intelligence. It simulates the cognitive processes that determine situation assessment and intention formation. It can be used to investigate analytically what situations and factors lead to intention failures, what actions follow from intention failures (e.g. errors of omission, errors of commission, common mode errors), the ability to recover from errors or additional machine failures, and the effects of changes in the NPP person machine system. One application of the CES modeling environment is to enhance the measurement of the human contribution to risk in probabilistic risk assessment studies. (author)

  17. Power Electronic Packaging Design, Assembly Process, Reliability and Modeling

    CERN Document Server

    Liu, Yong

    2012-01-01

    Power Electronic Packaging presents an in-depth overview of power electronic packaging design, assembly,reliability and modeling. Since there is a drastic difference between IC fabrication and power electronic packaging, the book systematically introduces typical power electronic packaging design, assembly, reliability and failure analysis and material selection so readers can clearly understand each task's unique characteristics. Power electronic packaging is one of the fastest growing segments in the power electronic industry, due to the rapid growth of power integrated circuit (IC) fabrication, especially for applications like portable, consumer, home, computing and automotive electronics. This book also covers how advances in both semiconductor content and power advanced package design have helped cause advances in power device capability in recent years. The author extrapolates the most recent trends in the book's areas of focus to highlight where further improvement in materials and techniques can d...

  18. Network reliability assessment using a cellular automata approach

    International Nuclear Information System (INIS)

    Rocco S, Claudio M.; Moreno, Jose Ali

    2002-01-01

    Two cellular automata (CA) models that evaluate the s-t connectedness and shortest path in a network are presented. CA based algorithms enhance the performance of classical algorithms, since they allow a more reliable and straightforward parallel implementation resulting in a dynamic network evaluation, where changes in the connectivity and/or link costs can readily be incorporated avoiding recalculation from scratch. The paper also demonstrates how these algorithms can be applied for network reliability evaluation (based on Monte-Carlo approach) and for finding s-t path with maximal reliability

  19. A method to assign failure rates for piping reliability assessments

    International Nuclear Information System (INIS)

    Gamble, R.M.; Tagart, S.W. Jr.

    1991-01-01

    This paper reports on a simplified method that has been developed to assign failure rates that can be used in reliability and risk studies of piping. The method can be applied on a line-by-line basis by identifying line and location specific attributes that can lead to piping unreliability from in-service degradation mechanisms and random events. A survey of service experience for nuclear piping reliability also was performed. The data from this survey provides a basis for identifying in-service failure attributes and assigning failure rates for risk and reliability studies

  20. Condition-based Human Reliability Assessment for digitalized control room

    International Nuclear Information System (INIS)

    Kang, H. G.; Jang, S. C.; Eom, H. S.; Ha, J. J.

    2005-04-01

    In safety-critical systems, the generation failure of an actuation signal is caused by the concurrent failures of the automated systems and an operator action. These two sources of safety signals are complicatedly correlated. The failures of sensors or automated systems will cause a lack of necessary information for a human operator and result in error-forcing contexts such as the loss of corresponding alarms and indications. In the conventional analysis, the Human Error Probabilities (HEP) are estimated based on the assumption of 'normal condition of indications and alarms'. In order to construct a more realistic signal-generation failure model, we have to consider more complicated conditions in a more realistic manner. In this study, we performed two kinds of investigation for addressing this issue. We performed the analytic calculations for estimating the effect of sensors failures on the system unavailability and plant risk. For the single-parameter safety signals, the analysis result reveals that the quantification of the HEP should be performed by focusing on the 'no alarm from the automatic system and corresponding indications unavailable' situation. This study also proposes a Condition-Based Human Reliability Assessment (CBHRA) method in order to address these complicated conditions in a practical way. We apply the CBHRA method to the manual actuation of the safety features such as a reactor trip and auxiliary feedwater actuation in Korean Standard Nuclear Power Plants. In the case of conventional single HEP method, it is very hard to consider the multiple HE conditions. The merit of CBHRA is clearly shown in the application to the AFAS generation where no dominating HE condition exits. In this case, even if the HE conditions are carefully investigated, the single HEP method cannot accommodate the multiple conditions in a fault tree. On the other hand, the application result of the reactor trip in SLOCA shows that if there is a dominating condition, the use

  1. SALP (Sensitivity Analysis by List Processing), a computer assisted technique for binary systems reliability analysis

    International Nuclear Information System (INIS)

    Astolfi, M.; Mancini, G.; Volta, G.; Van Den Muyzenberg, C.L.; Contini, S.; Garribba, S.

    1978-01-01

    A computerized technique which allows the modelling by AND, OR, NOT binary trees, of various complex situations encountered in safety and reliability assessment, is described. By the use of list-processing, numerical and non-numerical types of information are used together. By proper marking of gates and primary events, stand-by systems, common cause failure and multiphase systems can be analyzed. The basic algorithms used in this technique are shown in detail. Application to a stand-by and multiphase system is then illustrated

  2. Structural Reliability Methods for Wind Power Converter System Component Reliability Assessment

    DEFF Research Database (Denmark)

    Kostandyan, Erik; Sørensen, John Dalsgaard

    2012-01-01

    Wind power converter systems are essential subsystems in both off-shore and on-shore wind turbines. It is the main interface between generator and grid connection. This system is affected by numerous stresses where the main contributors might be defined as vibration and temperature loadings....... The temperature variations induce time-varying stresses and thereby fatigue loads. A probabilistic model is used to model fatigue failure for an electrical component in the power converter system. This model is based on a linear damage accumulation and physics of failure approaches, where a failure criterion...... is defined by the threshold model. The attention is focused on crack propagation in solder joints of electrical components due to the temperature loadings. Structural Reliability approaches are used to incorporate model, physical and statistical uncertainties. Reliability estimation by means of structural...

  3. Reliability demonstration methodology for products with Gamma Process by optimal accelerated degradation testing

    International Nuclear Information System (INIS)

    Zhang, Chunhua; Lu, Xiang; Tan, Yuanyuan; Wang, Yashun

    2015-01-01

    For products with high reliability and long lifetime, accelerated degradation testing (ADT) may be adopted during product development phase to verify whether its reliability satisfies the predetermined level within feasible test duration. The actual degradation from engineering is usually a strictly monotonic process, such as fatigue crack growth, wear, and erosion. However, the method for reliability demonstration by ADT with monotonic degradation process has not been investigated so far. This paper proposes a reliability demonstration methodology by ADT for this kind of product. We first apply Gamma process to describe the monotonic degradation. Next, we present a reliability demonstration method by converting the required reliability level into allowable cumulative degradation in ADT and comparing the actual accumulative degradation with the allowable level. Further, we suggest an analytical optimal ADT design method for more efficient reliability demonstration by minimizing the asymptotic variance of decision variable in reliability demonstration under the constraints of sample size, test duration, test cost, and predetermined decision risks. The method is validated and illustrated with example on reliability demonstration of alloy product, and is applied to demonstrate the wear reliability within long service duration of spherical plain bearing in the end. - Highlights: • We present a reliability demonstration method by ADT for products with monotonic degradation process, which may be applied to verify reliability with long service life for products with monotonic degradation process within feasible test duration. • We suggest an analytical optimal ADT design method for more efficient reliability demonstration, which differs from the existed optimal ADT design for more accurate reliability estimation by different objective function and different constraints. • The methods are applied to demonstrate the wear reliability within long service duration of

  4. Assessment and Improving Methods of Reliability Indices in Bakhtar Regional Electricity Company

    Directory of Open Access Journals (Sweden)

    Saeed Shahrezaei

    2013-04-01

    Full Text Available Reliability of a system is the ability of a system to do prospected duties in future and the probability of desirable operation for doing predetermined duties. Power system elements failures data are the main data of reliability assessment in the network. Determining antiseptic parameters is the goal of reliability assessment by using system history data. These parameters help to recognize week points of the system. In other words, the goal of reliability assessment is operation improving and decreasing of the failures and power outages. This paper is developed to assess reliability indices of Bakhtar Regional Electricity Company up to 1393 and the improving methods and their effects on the reliability indices in this network. DIgSILENT Power Factory software is employed for simulation. Simulation results show the positive effect of improving methods in reliability indices of Bakhtar Regional Electricity Company.

  5. Reliability assessment of Port Harcourt 33/11kv Distribution System ...

    African Journals Online (AJOL)

    This makes reliability studies an important task besides all the other analyses required for assessing the system performance. The paper presents an analytical approach in the reliability assessment of the Port Harcourt 33/11kV power distribution system. The assessment was performed with the 2009 power outage data ...

  6. The collection, storage and use of equipment performance data for the safety and reliability assessment of nuclear power plants

    International Nuclear Information System (INIS)

    Fothergill, C.D.H.

    1975-01-01

    It has been characteristic of the Nuclear Industry that it should grow up in an atmosphere where reliability and operational safety considerations have been of vital importance. Consequently all aspects of Nuclear Power Reactor design, construction and operation (in the U.K.A.E.A.) are subjected to rigorous reliability assessments, beginning with the automatic protective devices and the safety shut-down systems. This has resulted in the setting up of large and small private data stores to support this upsurgence of Safety and Reliability assessment work. Unfortunately, much of the information being stored and published falls short of the minimum requirements of Safety Assessors and Reliability Analysts who need to make use of it. That there is still an urgent need for more work to be done in the Reliability Data field is universally acknowledged. The characteristics which make up good quality reliability data must be defined and achievable minimum standards must be set for its identification, collection, storage and retrieval. To this end the United Kingdom Atomic Energy Authority have set up the Systems Reliability Service Data Bank. This includes a computerized storage facility comprised of two principal data stores: (i) Reliability Data Store, (ii) Event Data Store. The figures available in the Reliability Data Store range from those relating to the lifetimes of minute components to those obtained from the assessment of whole plants and complete assemblies. These data have been accumulated from many reliable sources both inside and outside the Nuclear Industry, including the transfer of 'live' data generated from the results of reliability surveillance exercises associated with Event Data collection. Computer techniques developed specifically for the Reliability Data Store enable further 'processing' of these data to be carried out. The Event Data Store consists of three discrete computerized data stores, each one providing the necessary storage, retrieval and

  7. Reliability of the Bulb Dynamometer for Assessing Grip Strength

    Directory of Open Access Journals (Sweden)

    Colleen Maher

    2018-04-01

    Full Text Available Background: Hand function is an overall indicator of health and is often measured using grip strength. Handheld dynamometry is the most common method of measuring grip strength. The purpose of this study was to determine the inter-rater and test-retest reliability, the reliability of one trial versus three trials, and the preliminary norms for a young adult population using the Baseline® Pneumatic Squeeze Bulb Dynamometer (30 psi. Methods: This study used a one-group methodological design. One hundred and three healthy adults (30 males and 73 females were recruited. Six measurements were collected for each hand per participant. The data was analyzed using Intraclass Correlation Coefficients (ICC two-way effects model (2,2 and paired-samples t-tests. Results: The ICC for inter-rater reliability ranged from 0.955 to 0.977. Conclusion: The results of this study suggest that the bulb dynamometer is a reliable tool to measure grip strength and should be further explored for reliable and valid use in diverse populations and as an alternative to the Jamar dynamometer.

  8. Performance assessment of coupled processes

    International Nuclear Information System (INIS)

    Pigford, T.H.

    1987-01-01

    The author considers all processes to be coupled. For example, a waste package heats the surrounding rock and its pore water, creating gradients in density and pressure that result in increased water flow. That process can be described as coupled, in that the flow is a consequence of heating. In a narrower sense, one speaks also of the more weakly coupled transport processes, expressed by the Onsager reciprocal relations, that state that a transport current, i.e., flux, of heat is accompanied by a small transport current of material, as evidenced in isotope separation by thermal diffusion, the Thompson effect in thermoelectricity, etc. This paper presents a performance assessment of coupled processes

  9. Configuration Management Process Assessment Strategy

    Science.gov (United States)

    Henry, Thad

    2014-01-01

    Purpose: To propose a strategy for assessing the development and effectiveness of configuration management systems within Programs, Projects, and Design Activities performed by technical organizations and their supporting development contractors. Scope: Various entities CM Systems will be assessed dependent on Project Scope (DDT&E), Support Services and Acquisition Agreements. Approach: Model based structured against assessing organizations CM requirements including best practices maturity criteria. The model is tailored to the entity being assessed dependent on their CM system. The assessment approach provides objective feedback to Engineering and Project Management of the observed CM system maturity state versus the ideal state of the configuration management processes and outcomes(system). center dot Identifies strengths and risks versus audit gotcha's (findings/observations). center dot Used "recursively and iteratively" throughout program lifecycle at select points of need. (Typical assessments timing is Post PDR/Post CDR) center dot Ideal state criteria and maturity targets are reviewed with the assessed entity prior to an assessment (Tailoring) and is dependent on the assessed phase of the CM system. center dot Supports exit success criteria for Preliminary and Critical Design Reviews. center dot Gives a comprehensive CM system assessment which ultimately supports configuration verification activities.*

  10. A Reliability Assessment Method for the VHTR Safety Systems

    International Nuclear Information System (INIS)

    Lee, Hyung Sok; Jae, Moo Sung; Kim, Yong Wan

    2011-01-01

    The Passive safety system by very high temperature reactor which has attracted worldwide attention in the last century is the reliability safety system introduced for the improvement in the safety of the next generation nuclear power plant design. The Passive system functionality does not rely on an external source of energy, but on an intelligent use of the natural phenomena, such as gravity, conduction and radiation, which are always present. Because of these features, it is difficult to evaluate the passive safety on the risk analysis methodology having considered the existing active system failure. Therefore new reliability methodology has to be considered. In this study, the preliminary evaluation and conceptualization are tried, applying the concept of the load and capacity from the reliability physics model, designing the new passive system analysis methodology, and the trial applying to paper plant.

  11. A questionnaire for assessing breastfeeding intentions and practices in Nigeria: validity, reliability and translation.

    Science.gov (United States)

    Emmanuel, Andy; Clow, Sheila E

    2017-06-07

    Validating a questionnaire/instrument (whether developed or adapted) before proceeding to the field for data collection is important. This article presents the modification of an Irish questionnaire for a Nigerian setting. The validation process and reliability testing of this questionnaire (which was used in assessing previous breastfeeding practices and breastfeeding intentions of pregnant women in English and Hausa languages) were also presented. Five experts in the field of breastfeeding and infant feeding voluntarily and independently evaluated the instrument. The experts evaluated the various items of the questionnaire based on relevance, clarity, simplicity and ambiguity on a Likert scale of 4. The analysis was performed to determine the content validity index (CVI).Two language experts performed the translation and back-translation. Ten pregnant women completed questionnaires which were evaluated for internal consistency. Two other pregnant women completed the questionnaire twice at an interval of two weeks to test the reliability. SPSS version 21 was used to calculate the coefficient of reliability. The content validity index was high (0.94 for relevance, clarity and ambiguity and 0.96 for simplicity). The analysis suggested that four of the seventy one items should be removed. Cronbach's Alpha was 0.81, while the reliability coefficient was 0.76. The emerged validated questionnaire was translated from English to Hausa, then, back-translated into English and compared for accuracy. The final instrument is reliable and valid for data collection on breastfeeding in Nigeria among English and Hausa speakers. Therefore, the instrument is recommended for use in assessing breastfeeding intention and practices in Nigeria.

  12. Reliability assessment of hydraulic cylinders considering service loads and flaw distribution

    International Nuclear Information System (INIS)

    Altamura, Alessandra; Beretta, Stefano

    2012-01-01

    Manufacturing process, service conditions and material properties are all necessary requirements to a good design of tubular mechanical components subjected to fatigue. The most common approach to this design is usually deterministic, where a fixed NDT threshold, related to flaw acceptance limit, is set. However many uncertainties are left aside, i.e. the failure probability related to the fatigue strength under applied loads. This paper addresses the reliability evaluation of tubular mechanical components carrying some flaws and subjected to cyclic internal pressure variation. The aim is comparing the probability of failure obtained under several assumptions. A reliability assessment model, based on a random variable approach, has been implemented by using the Monte Carlo method. The analysis of the results, from a case study based on load spectra measurements of hydraulic cylinders of earth moving machines, has consented to evaluate the most important factors influencing the fatigue life prediction of these components. Highlights: ► Reliability evaluation of tubular components subjected to variable internal pressure. ► The dispersion of the threshold controls the stochasticity of crack growth. ► A random variable model has been developed using Monte Carlo. ► Initial crack size and spectrum shape are key factors in reliability evaluation.

  13. Reliability assessment of underground pipelines under the combined effect of active corrosion and residual stress

    International Nuclear Information System (INIS)

    Amirat, A.; Mohamed-Chateauneuf, A.; Chaoui, K.

    2006-01-01

    Lifetime management of underground pipelines is mandatory for safe hydrocarbon transmission and distribution systems. Reliability analysis is recognized as a powerful decision-making tool for risk-based design and maintenance. Both the residual stresses generated during the manufacturing process and in-service corrosion reduce the ability to resist internal and external loading. In this study, the residual stress distribution in large diameter pipes has been characterized experimentally in order to be coupled with the corrosion model. During the pipe lifetime, residual stress relaxation occurs due to the loss of pipe thickness as material layers are consumed by corrosion. The reliability-based assessment of residual stress effects is applied to underground pipelines under a roadway, with and without active corrosion. It has been found that the residual stress greatly increases the failure probability, especially in the early stage of the pipe lifetime

  14. Component reliability data for use in probabilistic safety assessment

    International Nuclear Information System (INIS)

    1988-10-01

    Generic component reliability data is indispensable in any probabilistic safety analysis. It is not realistic to assume that all possible component failures and failure modes modeled in a PSA would be available from the operating experience of a specific plant in a statistically meaningful way. The degree that generic data is used in PSAs varies from case to case. Some studies are totally based on generic data while others use generic data as prior information to be specialized by plant specific data. Most studies, however, finally use a combination where data for certain components come from generic data sources and others from Bayesian updating. The IAEA effort to compile a generic component reliability data base aimed at facilitating the use of data available in the literature and at highlighting pitfalls which deserve special consideration. It was also intended to complement the fault tree and event tree package (PSAPACK) and to facilitate its use. Moreover, it should be noted, that the IAEA has recently initiated a Coordinated Research Program in Reliability Data Collection, Retrieval and Analysis. In this framework the issues identified as most affecting the quality of existing data bases would be addressed. This report presents the results of a compilation made from the specialized literature and includes reliability data for components usually considered in PSA

  15. Training Raters to Assess Adult ADHD: Reliability of Ratings

    Science.gov (United States)

    Adler, Lenard A.; Spencer, Thomas; Faraone, Stephen V.; Reimherr, Fred W.; Kelsey, Douglas; Michelson, David; Biederman, Joseph

    2005-01-01

    The standardization of ADHD ratings in adults is important given their differing symptom presentation. The authors investigated the agreement and reliability of rater standardization in a large-scale trial of atomoxetine in adults with ADHD. Training of 91 raters for the investigator-administered ADHD Rating Scale (ADHDRS-IV-Inv) occurred prior to…

  16. Re-assessing reliability based on survived loads

    NARCIS (Netherlands)

    Schweckendiek, T.

    2011-01-01

    The reliability of flood defenses is often dictated by large uncertainties in the hydraulic loading and the structural resistance. Additional information decreases uncertainty, however, acquiring it is often costly. One source of information, even though in many cases readily available, is hardly

  17. Assessing Assertion: An Investigation of Construct Validity and Reliability.

    Science.gov (United States)

    Kern, Jeffrey M.; MacDonald, Marian L.

    The reliability and meaning of assertiveness tests were explored using 120 female undergraduates. Several self-report inventories (the College Self-Expression Scale, Conflict Resolution Inventory, and a global rating from one to seven) were administered, as were three anxiety measures (Timed Behavior Checklist, response latency, and response…

  18. Pattern Recognition for Reliability Assessment of Water Distribution Networks

    NARCIS (Netherlands)

    Trifunovi?, N.

    2012-01-01

    The study presented in this manuscript investigates the patterns that describe reliability of water distribution networks focusing to the node connectivity, energy balance, and economics of construction, operation and maintenance. A number of measures to evaluate the network resilience has been

  19. Assessment of the Reliability Profiles for Concrete Bridges

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    In this paper calculation of reliability profiles is discussed. ULS as well as SLS limit states are formulated. Corrosion due to chloride penetration is the considered deterioration mechanism. Three models for corrosion are formulated. A definition of service lifetime for concrete bridges...

  20. Technical report on reliability assessment of the digital I and C equipment using reliability block diagram

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Young; Hwang, In Koo; Cha, Kyung Ho; Park, Joo Hyun; Choi, Jong Gyun; Lee, Ki Young; Park, Jong Kyun [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-03-01

    As the operational life-time of nuclear power plants being currently developed is increasing with technology improvements, the life-time of instrumentation and control systems is also required to be met to this plant operational period. The electronic devices are usually expected to be available less than for 10 years. Therefore, an appropriate S and PM (surveillance and preventive maintenance) strategy should be established to secure the reliability and availability of the plants. EPRI-URD requires that the mean time between failures caused by any I and C system failure shall be more than 50 operating years. The methodology to access of the mean time between failures of I and C system is included in this report. 35 refs., 19 figs., 3 tabs. (Author)

  1. Uncertainty Quantification in the Reliability and Risk Assessment of Generation IV Reactors: Final Scientific/Technical Report

    International Nuclear Information System (INIS)

    Vierow, Karen; Aldemir, Tunc

    2009-01-01

    The project entitled, 'Uncertainty Quantification in the Reliability and Risk Assessment of Generation IV Reactors', was conducted as a DOE NERI project collaboration between Texas A and M University and The Ohio State University between March 2006 and June 2009. The overall goal of the proposed project was to develop practical approaches and tools by which dynamic reliability and risk assessment techniques can be used to augment the uncertainty quantification process in probabilistic risk assessment (PRA) methods and PRA applications for Generation IV reactors. This report is the Final Scientific/Technical Report summarizing the project.

  2. Uncertainty Quantification in the Reliability and Risk Assessment of Generation IV Reactors: Final Scientific/Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Vierow, Karen; Aldemir, Tunc

    2009-09-10

    The project entitled, “Uncertainty Quantification in the Reliability and Risk Assessment of Generation IV Reactors”, was conducted as a DOE NERI project collaboration between Texas A&M University and The Ohio State University between March 2006 and June 2009. The overall goal of the proposed project was to develop practical approaches and tools by which dynamic reliability and risk assessment techniques can be used to augment the uncertainty quantification process in probabilistic risk assessment (PRA) methods and PRA applications for Generation IV reactors. This report is the Final Scientific/Technical Report summarizing the project.

  3. A prospective study assessing agreement and reliability of a geriatric evaluation.

    Science.gov (United States)

    Locatelli, Isabella; Monod, Stéfanie; Cornuz, Jacques; Büla, Christophe J; Senn, Nicolas

    2017-07-19

    The present study takes place within a geriatric program, aiming at improving the diagnosis and management of geriatric syndromes in primary care. Within this program it was of prime importance to be able to rely on a robust and reproducible geriatric consultation to use as a gold standard for evaluating a primary care brief assessment tool. The specific objective of the present study was thus assessing the agreement and reliability of a comprehensive geriatric consultation. The study was conducted at the outpatient clinic of the Service of Geriatric Medicine, University of Lausanne, Switzerland. All community-dwelling older persons aged 70 years and above were eligible. Patients were excluded if they hadn't a primary care physician, they were unable to speak French, or they were already assessed by a geriatrician within the last 12 months. A set of 9 geriatricians evaluated 20 patients. Each patient was assessed twice within a 2-month delay. Geriatric consultations were based on a structured evaluation process, leading to rating the following geriatric conditions: functional, cognitive, visual, and hearing impairment, mood disorders, risk of fall, osteoporosis, malnutrition, and urinary incontinence. Reliability and agreement estimates on each of these items were obtained using a three-way Intraclass Correlation and a three-way Observed Disagreement index. The latter allowed a decomposition of overall disagreement into disagreements due to each source of error variability (visit, rater and random). Agreement ranged between 0.62 and 0.85. For most domains, geriatrician-related error variability explained an important proportion of disagreement. Reliability ranged between 0 and 0.8. It was poor/moderate for visual impairment, malnutrition and risk of fall, and good/excellent for functional/cognitive/hearing impairment, osteoporosis, incontinence and mood disorders. Six out of nine items of the geriatric consultation described in this study (functional

  4. Fast Reliability Assessing Method for Distribution Network with Distributed Renewable Energy Generation

    Science.gov (United States)

    Chen, Fan; Huang, Shaoxiong; Ding, Jinjin; Ding, Jinjin; Gao, Bo; Xie, Yuguang; Wang, Xiaoming

    2018-01-01

    This paper proposes a fast reliability assessing method for distribution grid with distributed renewable energy generation. First, the Weibull distribution and the Beta distribution are used to describe the probability distribution characteristics of wind speed and solar irradiance respectively, and the models of wind farm, solar park and local load are built for reliability assessment. Then based on power system production cost simulation probability discretization and linearization power flow, a optimal power flow objected with minimum cost of conventional power generation is to be resolved. Thus a reliability assessment for distribution grid is implemented fast and accurately. The Loss Of Load Probability (LOLP) and Expected Energy Not Supplied (EENS) are selected as the reliability index, a simulation for IEEE RBTS BUS6 system in MATLAB indicates that the fast reliability assessing method calculates the reliability index much faster with the accuracy ensured when compared with Monte Carlo method.

  5. Generation reliability assessment in oligopoly power market using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Haroonabadi, H.; Haghifam, M.R.

    2007-01-01

    This paper addressed issues regarding power generation reliability assessment (HLI) in deregulated power pool markets. Most HLI reliability evaluation methods are based on the loss of load (LOLE) approach which is among the most suitable indices to describe the level of generation reliability. LOLE refers to the time in which load is greater than the amount of available generation. While most reliability assessments deal only with power system constraints, this study considered HLI reliability assessment in an oligopoly power market using Monte Carlo simulation (MCS). It evaluated the sensitivity of the reliability index to different reserve margins and future margins. The reliability index was determined by intersecting the offer and demand curves of power plants and comparing them to other parameters. The paper described the fundamentals of an oligopoly power pool market and proposed an algorithm for HLI reliability assessment for such a market. The proposed method was assessed on the IEEE-Reliability Test System with satisfactory results. In all cases, generation reliability indices were evaluated with different reserve margins and various load levels. 19 refs., 7 figs., 1 appendix

  6. Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR): Volume 1, Summary description

    International Nuclear Information System (INIS)

    Gertman, D.I.; Gilmore, W.E.; Galyean, W.J.; Groh, M.R.; Gentillon, C.D.; Gilbert, B.G.

    1988-02-01

    A data management system has been implemented which supports a variety of risk-related analyses and provides a repository of hardware component failure and human error probability data to the risk analyst. The Nuclear Computerized Library for Assessing Reactor Reliability, NUCLARR, is an interactive, graphically oriented system which resides on a personal computer (PC) or PC-compatible environment. An overview of the data management system, including a description of data collection, specification, data structure, and taxonomies, is presented in Volume I of this report. Programming activities, procedures for processing data, user's guide, and hard copy data manual are presented in Volumes II through V

  7. A Structural Reliability Business Process Modelling with System Dynamics Simulation

    OpenAIRE

    Lam, C. Y.; Chan, S. L.; Ip, W. H.

    2010-01-01

    Business activity flow analysis enables organizations to manage structured business processes, and can thus help them to improve performance. The six types of business activities identified here (i.e., SOA, SEA, MEA, SPA, MSA and FIA) are correlated and interact with one another, and the decisions from any business activity form feedback loops with previous and succeeding activities, thus allowing the business process to be modelled and simulated. For instance, for any company that is eager t...

  8. Electric Power quality Analysis in research reactor: Impacts on nuclear safety assessment and electrical distribution reliability

    International Nuclear Information System (INIS)

    Touati, Said; Chennai, Salim; Souli, Aissa

    2015-01-01

    The increased requirements on supervision, control, and performance in modern power systems make power quality monitoring a common practise for utilities. Large databases are created and automatic processing of the data is required for fast and effective use of the available information. Aim of the work presented in this paper is the development of tools for analysis of monitoring power quality data and in particular measurements of voltage and currents in various level of electrical power distribution. The study is extended to evaluate the reliability of the electrical system in nuclear plant. Power Quality is a measure of how well a system supports reliable operation of its loads. A power disturbance or event can involve voltage, current, or frequency. Power disturbances can originate in consumer power systems, consumer loads, or the utility. The effect of power quality problems is the loss power supply leading to severe damage to equipments. So, we try to track and improve system reliability. The assessment can be focused on the study of impact of short circuits on the system, harmonics distortion, power factor improvement and effects of transient disturbances on the Electrical System during motor starting and power system fault conditions. We focus also on the review of the Electrical System design against the Nuclear Directorate Safety Assessment principles, including those extended during the last Fukushima nuclear accident. The simplified configuration of the required system can be extended from this simple scheme. To achieve these studies, we have used a demo ETAP power station software for several simulations. (authors)

  9. Electric Power quality Analysis in research reactor: Impacts on nuclear safety assessment and electrical distribution reliability

    Energy Technology Data Exchange (ETDEWEB)

    Touati, Said; Chennai, Salim; Souli, Aissa [Nuclear Research Centre of Birine, Ain Oussera, Djelfa Province (Algeria)

    2015-07-01

    The increased requirements on supervision, control, and performance in modern power systems make power quality monitoring a common practise for utilities. Large databases are created and automatic processing of the data is required for fast and effective use of the available information. Aim of the work presented in this paper is the development of tools for analysis of monitoring power quality data and in particular measurements of voltage and currents in various level of electrical power distribution. The study is extended to evaluate the reliability of the electrical system in nuclear plant. Power Quality is a measure of how well a system supports reliable operation of its loads. A power disturbance or event can involve voltage, current, or frequency. Power disturbances can originate in consumer power systems, consumer loads, or the utility. The effect of power quality problems is the loss power supply leading to severe damage to equipments. So, we try to track and improve system reliability. The assessment can be focused on the study of impact of short circuits on the system, harmonics distortion, power factor improvement and effects of transient disturbances on the Electrical System during motor starting and power system fault conditions. We focus also on the review of the Electrical System design against the Nuclear Directorate Safety Assessment principles, including those extended during the last Fukushima nuclear accident. The simplified configuration of the required system can be extended from this simple scheme. To achieve these studies, we have used a demo ETAP power station software for several simulations. (authors)

  10. The solution of the reliability problem in the repair process of the plates of the silica bricks press boxes

    Directory of Open Access Journals (Sweden)

    Nochvai V.М.

    2017-05-01

    Full Text Available The research analyzes recommendations existing in different sources of information for the choice of methods of strengthening and reconditioning of worn machine parts. These methods include: the method of electric arc deposition, chemical-thermal treatment, gas-powder deposition, gas-powder and plasma spraying, electric arc metallization. As a result of studies of wear of the working surfaces of the plates of silicate brick press boxes, we define that the plates wear out unevenly and the thickness of the worn layer varies between 0.3 ... 2 mm. Technological method is chosen as the method of the plate reliability enhancement and maintaining. One of the main technological stages of reliability formation is machine parts strengthening using the methods of strengthening technologies, namely electric arc metallization. Wire models Нп-65Г, ФМИ-2, Нп-40Х13 are used to develop wear-resistant coatings with desired properties. Technological process of the plates repair consists of the following basic operations: plate preparation, wire preparation, plate coating, plate grinding, final checking. Single and complex reliability indicators are determined by testing a set of the plates and registering all the indicators (operating time, failures, faults. The value of the economic reliability index of the plate Kе equals to 0,10. Higher plate reliability is achieved at the expense of extra cost for plate strengthening using wire Нп-40Х13, and the price of Bн plate reliability is 104,83 UAH. Complex indicators of reliability of the reconditioned plate of the silica bricks press boxes are used for more complete reliability assessment. Availability coefficient Kг. equals to 0,995 and characterizes two different properties simultaneously: reliability and maintainability. Coefficient of technical use Kт.в. equals to 0,974 and most fully characterizes the reliability of the plates because it considers time in the process of maintenance, repair and

  11. Federal environmental assessment panel process

    International Nuclear Information System (INIS)

    Edwards, R.A.; King, J.M.

    1996-01-01

    The Government of Canada inaugurated an environmental assessment process in 1973. Since that time, the Department of Natural Resources, or its predecessor, the Department of Energy Mines and Resources, and industrial clients of the Department, have been major participants in the process. In 1995, the authors interviewed representatives of a number of client industries and selected individuals, to ask their opinion of the public hearing part of the environmental assessment process, with the objective of identifying shortcomings and proposing improvements. Respondents criticized the hearings as costly, time-wasting, bureaucratic, and uncertain in cost, time, and outcome. A number of observations on noted areas of shortcoming are presented in this paper, with suggestions for improvement

  12. Federal environmental assessment panel process

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, R A; King, J M [Natural Resources Canada, Ottawa, ON (Canada)

    1997-12-31

    The Government of Canada inaugurated an environmental assessment process in 1973. Since that time, the Department of Natural Resources, or its predecessor, the Department of Energy Mines and Resources, and industrial clients of the Department, have been major participants in the process. In 1995, the authors interviewed representatives of a number of client industries and selected individuals, to ask their opinion of the public hearing part of the environmental assessment process, with the objective of identifying shortcomings and proposing improvements. Respondents criticized the hearings as costly, time-wasting, bureaucratic, and uncertain in cost, time, and outcome. A number of observations on noted areas of shortcoming are presented in this paper, with suggestions for improvement.

  13. Reliability assessment of the containment of a PWR

    International Nuclear Information System (INIS)

    Schueller, G.I.; Wellein, R.; Wittmann, F.H.; Boulahdour, T.; Mihashi, M.; Zorn, N.F.; Bauer, J.

    1981-09-01

    The aim of this research effort was to contribute to the development of methods to quantify the risk involved with nuclear power plants. Using a large component, i.e. the containment of the reference plant BIBLIS B (PWR) as sample structure a reliability analysis was performed which is based on realistic assumptions of loads and material properties. For this purpose in many fields it was necessary to develop new methods, collect data, and where not available, obtain data in tests. This effort concentrated on partial aspects and on the other hand on the development of a methodology for an overall reliability concept. According to the results of the previous project, the keypoints of this effort are the treatment of loss of coolant accidents (small leak), earthquake loading, the possibly resulting crackpropagation in the steel hull, and the structural mechanics and material strength aspects of the reinforced concrete hull subjected to impact loading (aircraft impact). (orig./HP) [de

  14. Reliability evaluation of hard disk drive failures based on counting processes

    International Nuclear Information System (INIS)

    Ye, Zhi-Sheng; Xie, Min; Tang, Loon-Ching

    2013-01-01

    Reliability assessment for hard disk drives (HDDs) is important yet difficult for manufacturers. Motivated by the fact that the particle accumulation in the HDDs, which accounts for most HDD catastrophic failures, is contributed from the internal and external sources, a counting process with two arrival sources is proposed to model the particle cumulative process in HDDs. This model successfully explains the collapse of traditional ALT approaches for accelerated life test data. Parameter estimation and hypothesis tests for the model are developed and illustrated with real data from a HDD test. A simulation study is conducted to examine the accuracy of large sample normal approximations that are used to test existence of the internal and external sources.

  15. Assessment of teacher competence using video portfolios: reliability, construct validity and consequential validity

    NARCIS (Netherlands)

    Admiraal, W.; Hoeksma, M.; van de Kamp, M.-T.; van Duin, G.

    2011-01-01

    The richness and complexity of video portfolios endanger both the reliability and validity of the assessment of teacher competencies. In a post-graduate teacher education program, the assessment of video portfolios was evaluated for its reliability, construct validity, and consequential validity.

  16. Reliability and validity of a tool to assess airway management skills in anesthesia trainees

    Directory of Open Access Journals (Sweden)

    Aliya Ahmed

    2016-01-01

    Conclusion: The tool designed to assess bag-mask ventilation and tracheal intubation skills in anesthesia trainees demonstrated excellent inter-rater reliability, fair test-retest reliability, and good construct validity. The authors recommend its use for formative and summative assessment of junior anesthesia trainees.

  17. Development and preliminary reliability of a multitasking assessment for executive functioning after concussion.

    Science.gov (United States)

    Smith, Laurel B; Radomski, Mary Vining; Davidson, Leslie Freeman; Finkelstein, Marsha; Weightman, Margaret M; McCulloch, Karen L; Scherer, Matthew R

    2014-01-01

    OBJECTIVES. Executive functioning deficits may result from concussion. The Charge of Quarters (CQ) Duty Task is a multitask assessment designed to assess executive functioning in servicemembers after concussion. In this article, we discuss the rationale and process used in the development of the CQ Duty Task and present pilot data from the preliminary evaluation of interrater reliability (IRR). METHOD. Three evaluators observed as 12 healthy participants performed the CQ Duty Task and measured performance using various metrics. Intraclass correlation coefficient (ICC) quantified IRR. RESULTS. The ICC for task completion was .94. ICCs for other assessment metrics were variable. CONCLUSION. Preliminary IRR data for the CQ Duty Task are encouraging, but further investigation is needed to improve IRR in some domains. Lessons learned in the development of the CQ Duty Task could benefit future test development efforts with populations other than the military. Copyright © 2014 by the American Occupational Therapy Association, Inc.

  18. Human Reliability in Probabilistic Safety Assessments; Fiabilidad Humana en los Analisis Probabilisticos de Seguridad

    Energy Technology Data Exchange (ETDEWEB)

    Nunez Mendez, J

    1989-07-01

    Nowadays a growing interest in environmental aspects is detected in our country. It implies an assessment of the risk involved in the industrial processes and installations in order to determine if those are into the acceptable limits. In these safety assessments, among which PSA (Probabilistic Safety Assessments), can be pointed out the role played by the human being in the system is one of the more relevant subjects (This relevance has been demonstrated in the accidents happened) . However, in Spain there aren't manuals specifically dedicated to asses the human contribution to risk in the frame of PSAs. This report aims to improve this situation providing: a) a theoretical background to help the reader in the understanding of the nature of the human error, b) a quid to carry out a Human Reliability Analysis and c) a selected overview of the techniques and methodologies currently applied in this area. (Author) 20 refs.

  19. Human Reliability in Probabilistic Safety Assessments; Fiabilidad Humana en los Analisis Probabilisticos de Seguridad

    Energy Technology Data Exchange (ETDEWEB)

    Nunez Mendez, J.

    1989-07-01

    Nowadays a growing interest in environmental aspects is detected in our country. It implies an assessment of the risk involved in the industrial processes and installations in order to determine if those are into the acceptable limits. In these safety assessments, among which PSA (Probabilistic Safety Assessments), can be pointed out the role played by the human being in the system is one of the more relevant subjects (This relevance has been demonstrated in the accidents happened) . However, in Spain there aren't manuals specifically dedicated to asses the human contribution to risk in the frame of PSAs. This report aims to improve this situation providing: a) a theoretical background to help the reader in the understanding of the nature of the human error, b) a quid to carry out a Human Reliability Analysis and c) a selected overview of the techniques and methodologies currently applied in this area. (Author) 20 refs.

  20. Advancing methods for reliably assessing motivational interviewing fidelity using the motivational interviewing skills code.

    Science.gov (United States)

    Lord, Sarah Peregrine; Can, Doğan; Yi, Michael; Marin, Rebeca; Dunn, Christopher W; Imel, Zac E; Georgiou, Panayiotis; Narayanan, Shrikanth; Steyvers, Mark; Atkins, David C

    2015-02-01

    The current paper presents novel methods for collecting MISC data and accurately assessing reliability of behavior codes at the level of the utterance. The MISC 2.1 was used to rate MI interviews from five randomized trials targeting alcohol and drug use. Sessions were coded at the utterance-level. Utterance-based coding reliability was estimated using three methods and compared to traditional reliability estimates of session tallies. Session-level reliability was generally higher compared to reliability using utterance-based codes, suggesting that typical methods for MISC reliability may be biased. These novel methods in MI fidelity data collection and reliability assessment provided rich data for therapist feedback and further analyses. Beyond implications for fidelity coding, utterance-level coding schemes may elucidate important elements in the counselor-client interaction that could inform theories of change and the practice of MI. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Validity and Reliability of Field-Based Measures for Assessing Movement Skill Competency in Lifelong Physical Activities: A Systematic Review.

    Science.gov (United States)

    Hulteen, Ryan M; Lander, Natalie J; Morgan, Philip J; Barnett, Lisa M; Robertson, Samuel J; Lubans, David R

    2015-10-01

    It has been suggested that young people should develop competence in a variety of 'lifelong physical activities' to ensure that they can be active across the lifespan. The primary aim of this systematic review is to report the methodological properties, validity, reliability, and test duration of field-based measures that assess movement skill competency in lifelong physical activities. A secondary aim was to clearly define those characteristics unique to lifelong physical activities. A search of four electronic databases (Scopus, SPORTDiscus, ProQuest, and PubMed) was conducted between June 2014 and April 2015 with no date restrictions. Studies addressing the validity and/or reliability of lifelong physical activity tests were reviewed. Included articles were required to assess lifelong physical activities using process-oriented measures, as well as report either one type of validity or reliability. Assessment criteria for methodological quality were adapted from a checklist used in a previous review of sport skill outcome assessments. Movement skill assessments for eight different lifelong physical activities (badminton, cycling, dance, golf, racquetball, resistance training, swimming, and tennis) in 17 studies were identified for inclusion. Methodological quality, validity, reliability, and test duration (time to assess a single participant), for each article were assessed. Moderate to excellent reliability results were found in 16 of 17 studies, with 71% reporting inter-rater reliability and 41% reporting intra-rater reliability. Only four studies in this review reported test-retest reliability. Ten studies reported validity results; content validity was cited in 41% of these studies. Construct validity was reported in 24% of studies, while criterion validity was only reported in 12% of studies. Numerous assessments for lifelong physical activities may exist, yet only assessments for eight lifelong physical activities were included in this review

  2. Silicon analog components device design, process integration, characterization, and reliability

    CERN Document Server

    El-Kareh, Badih

    2015-01-01

    This book covers modern analog components, their characteristics, and interactions with process parameters. It serves as a comprehensive guide, addressing both the theoretical and practical aspects of modern silicon devices and the relationship between their electrical properties and processing conditions. Based on the authors’ extensive experience in the development of analog devices, this book is intended for engineers and scientists in semiconductor research, development and manufacturing. The problems at the end of each chapter and the numerous charts, figures and tables also make it appropriate for use as a text in graduate and advanced undergraduate courses in electrical engineering and materials science.

  3. RELIABILITY ASSESSMENT OF ENTROPY METHOD FOR SYSTEM CONSISTED OF IDENTICAL EXPONENTIAL UNITS

    Institute of Scientific and Technical Information of China (English)

    Sun Youchao; Shi Jun

    2004-01-01

    The reliability assessment of unit-system near two levels is the most important content in the reliability multi-level synthesis of complex systems. Introducing the information theory into system reliability assessment, using the addible characteristic of information quantity and the principle of equivalence of information quantity, an entropy method of data information conversion is presented for the system consisted of identical exponential units. The basic conversion formulae of entropy method of unit test data are derived based on the principle of information quantity equivalence. The general models of entropy method synthesis assessment for system reliability approximate lower limits are established according to the fundamental principle of the unit reliability assessment. The applications of the entropy method are discussed by way of practical examples. Compared with the traditional methods, the entropy method is found to be valid and practicable and the assessment results are very satisfactory.

  4. On the use of NDT Data for Reliability-Based Assessment of Existing Timber Structures

    DEFF Research Database (Denmark)

    Sousa, Hélder S.; Sørensen, John Dalsgaard; Kirkegaard, Poul Henning

    2013-01-01

    The objective of this paper is to address the possibilities of using non-destructive testing (NDT) data for updating information and obtaining adequate characterization of the reliability level of existing timber structures and, also, for assessing the evolution in time of performance...... of these structures when exposed to deterioration. By improving the knowledge upon the mechanical properties of timber, better and more substantiated decisions after a reliability safety assessment are aimed at. Bayesian methods are used to update the mechanical properties of timber and reliability assessment......, and information of NDT is also used to calibrate these models. The proposed approach is used for reliability assessment of different structural timber systems. Reliability of the structural system is assessed regarding the failure consequences of individual elements defined as key elements which were determined...

  5. FE modeling of Cu wire bond process and reliability

    NARCIS (Netherlands)

    Yuan, C.A.; Weltevreden, E.R.; Akker, P. van den; Kregting, R.; Vreugd, J. de; Zhang, G.Q.

    2011-01-01

    Copper based wire bonding technology is widely accepted by electronic packaging industry due to the world-wide cost reduction actions (compared to gold wire bond). However, the mechanical characterization of copper wire differs from the gold wire; hence the new wire bond process setting and new bond

  6. Prediction of thermo-mechanical reliability of wafer backend processes

    NARCIS (Netherlands)

    Gonda, V.; Toonder, den J.M.J.; Beijer, J.G.J.; Zhang, G.Q.; van Driel, W.D.; Hoofman, R.J.O.M.; Ernst, L.J.

    2004-01-01

    More than 65% of IC failures are related to thermal and mechanical problems. For wafer backend processes, thermo-mechanical failure is one of the major bottlenecks. The ongoing technological trends like miniaturization, introduction of new materials, and function/product integration will increase

  7. "The Reliability, Validity, and Utility of Self-Assessment"

    Directory of Open Access Journals (Sweden)

    John A. Ross

    2006-11-01

    Full Text Available Despite widespread use of self-assessment, teachers have doubts about the value and accuracy of the technique. This article reviews research evidence on student self-assessment, finding that (1 self-assessment produces consistent results across items, tasks, and short time periods; (2 self-assessment provides information about student achievement that corresponds only in part to the information generated by teacher assessments; (3 self-assessment contributes to higher student achievement and improved behavior. The central finding of this review is that (4 the strengths of self-assessment can be enhanced through training students how to assess their work and each of the weaknesses of the approach (including inflation of grades can be reduced through teacher action.

  8. Remaining life prediction of I and C cables for reliability assessment of NPP systems

    International Nuclear Information System (INIS)

    Santhosh, T.V.; Ghosh, A.K.; Fernandes, B.G.

    2012-01-01

    Highlights: ► A framework for time dependent reliability prediction of I and C cables for use in PSA of NPP has been developed using stress–strength interference theory. ► The proposed methodology has been illustrated with the accelerated thermal aging data on a typical XLPE cable. ► The behavior of insulation resistance when the degradation process is linear or exponential has also been modeled. ► The reliability index or probability of failure obtained from this approach can be used in system reliability evaluation to account for cable aging for PSA of NPP. - Abstract: Instrumentation and control (I and C) cables are one of the most important components in nuclear power plants (NPPs) because they provide power to safety-related equipment and also to transmit signals to and from various controllers to perform safety operations. I and C cables in NPP are subjected to a variety of aging and degradation stressors that can produce immediate degradation or aging-related mechanisms causing the degradation of cable components over time. Although, there exits several life estimation techniques, currently there is no any standard methodology or an approach toward estimating the time dependent reliability of I and C cables that can be directly used in probabilistic safety assessment (PSA) applications. Hence, the objective of this study is to develop an approach to estimate and confirm the continued acceptable margin in cable insulation life over time subjected to aging. This paper presents a framework based on the structural reliability theory to quantify the life time of I and C cable subjecting to thermal aging. Since cross-linked polyethylene (XLPE) cables are extensively being used in Indian NPPs, the remaining life time evaluations have been carried out for a typical XLPE cable. However, the methodology can be extended to other cables such as polyvinyl chloride (PVC), ethylene propylene rubber (EPR), etc.

  9. Using the Reliability Theory for Assessing the Decision Confidence Probability for Comparative Life Cycle Assessments.

    Science.gov (United States)

    Wei, Wei; Larrey-Lassalle, Pyrène; Faure, Thierry; Dumoulin, Nicolas; Roux, Philippe; Mathias, Jean-Denis

    2016-03-01

    Comparative decision making process is widely used to identify which option (system, product, service, etc.) has smaller environmental footprints and for providing recommendations that help stakeholders take future decisions. However, the uncertainty problem complicates the comparison and the decision making. Probability-based decision support in LCA is a way to help stakeholders in their decision-making process. It calculates the decision confidence probability which expresses the probability of a option to have a smaller environmental impact than the one of another option. Here we apply the reliability theory to approximate the decision confidence probability. We compare the traditional Monte Carlo method with a reliability method called FORM method. The Monte Carlo method needs high computational time to calculate the decision confidence probability. The FORM method enables us to approximate the decision confidence probability with fewer simulations than the Monte Carlo method by approximating the response surface. Moreover, the FORM method calculates the associated importance factors that correspond to a sensitivity analysis in relation to the probability. The importance factors allow stakeholders to determine which factors influence their decision. Our results clearly show that the reliability method provides additional useful information to stakeholders as well as it reduces the computational time.

  10. Using the Hemophilia Joint Health Score for assessment of children: Reliability of the Spanish version.

    Science.gov (United States)

    R, Cuesta-Barriuso; A, Torres-Ortuño; S, Pérez-Alenda; J, Carrasco Juan; F, Querol; J, Nieto-Munuera; Ja, López-Pina

    2018-02-27

    Numerous measuring instruments for the evaluation of hemophilic arthropathy have been developed. One of the most used systems is the Hemophilia Joint Health Score (HJHS) given its sensitivity to clinical changes appearing in the joints because of recurrent hemarthrosis. Assessing the interrater reliability, using the Spanish version of the HJHS (version 2.1) in children with hemophilia. Reliability study to assess the interrater reliability of the Spanish version of HJHS. A sample of 36 children aged 7-13 years diagnosed with hemophilia A or B was used. Two physiotherapists performed physical assessments with the Spanish version of the HJHS. Descriptive statistics (range, mean, standard deviation) and the analysis of interrater reliability were calculated. The interrater reliability was heterogeneous since the Kappa coefficient range (ĸ), although significant (p reliability of the Spanish population version of the HJHS is high. This scale should be used generically in evaluating musculoskeletal pediatric patients with hemophilia.

  11. Dependence assessment in human reliability analysis based on D numbers and AHP

    International Nuclear Information System (INIS)

    Zhou, Xinyi; Deng, Xinyang; Deng, Yong; Mahadevan, Sankaran

    2017-01-01

    Highlights: • D numbers and AHP are combined to implement dependence assessment in HRA. • A new tool, called D numbers, is used to deal with the uncertainty in HRA. • The proposed method can well address the fuzziness and subjectivity in linguistic assessment. • The proposed method is well applicable in dependence assessment which inherently has a linguistic assessment process. - Abstract: Since human errors always cause heavy loss especially in nuclear engineering, human reliability analysis (HRA) has attracted more and more attention. Dependence assessment plays a vital role in HRA, measuring the dependence degree of human errors. Many researches have been done while still have improvement space. In this paper, a dependence assessment model based on D numbers and analytic hierarchy process (AHP) is proposed. Firstly, identify the factors used to measure the dependence level of two human operations. Besides, in terms of the suggested dependence level, determine and quantify the anchor points for each factor. Secondly, D numbers and AHP are adopted in model. Experts evaluate the dependence level of human operations for each factor. Then, the evaluation results are presented as D numbers and fused by D number’s combination rule that can obtain the dependence probability of human operations for each factor. The weights of factors can be determined by AHP. Thirdly, based on the dependence probability for each factor and its corresponding weight, the dependence probability of two human operations and its confidence can be obtained. The proposed method can well address the fuzziness and subjectivity in linguistic assessment. The proposed method is well applicable to assess the dependence degree of human errors in HRA which inherently has a linguistic assessment process.

  12. Dependence assessment in human reliability analysis based on D numbers and AHP

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xinyi; Deng, Xinyang [School of Computer and Information Science, Southwest University, Chongqing 400715 (China); Deng, Yong, E-mail: ydeng@swu.edu.cn [School of Computer and Information Science, Southwest University, Chongqing 400715 (China); Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054 (China); Mahadevan, Sankaran [School of Engineering, Vanderbilt University, Nashville, TN 37235 (United States)

    2017-03-15

    Highlights: • D numbers and AHP are combined to implement dependence assessment in HRA. • A new tool, called D numbers, is used to deal with the uncertainty in HRA. • The proposed method can well address the fuzziness and subjectivity in linguistic assessment. • The proposed method is well applicable in dependence assessment which inherently has a linguistic assessment process. - Abstract: Since human errors always cause heavy loss especially in nuclear engineering, human reliability analysis (HRA) has attracted more and more attention. Dependence assessment plays a vital role in HRA, measuring the dependence degree of human errors. Many researches have been done while still have improvement space. In this paper, a dependence assessment model based on D numbers and analytic hierarchy process (AHP) is proposed. Firstly, identify the factors used to measure the dependence level of two human operations. Besides, in terms of the suggested dependence level, determine and quantify the anchor points for each factor. Secondly, D numbers and AHP are adopted in model. Experts evaluate the dependence level of human operations for each factor. Then, the evaluation results are presented as D numbers and fused by D number’s combination rule that can obtain the dependence probability of human operations for each factor. The weights of factors can be determined by AHP. Thirdly, based on the dependence probability for each factor and its corresponding weight, the dependence probability of two human operations and its confidence can be obtained. The proposed method can well address the fuzziness and subjectivity in linguistic assessment. The proposed method is well applicable to assess the dependence degree of human errors in HRA which inherently has a linguistic assessment process.

  13. Materials and processes for spacecraft and high reliability applications

    CERN Document Server

    D Dunn, Barrie

    2016-01-01

    The objective of this book is to assist scientists and engineers select the ideal material or manufacturing process for particular applications; these could cover a wide range of fields, from light-weight structures to electronic hardware. The book will help in problem solving as it also presents more than 100 case studies and failure investigations from the space sector that can, by analogy, be applied to other industries. Difficult-to-find material data is included for reference. The sciences of metallic (primarily) and organic materials presented throughout the book demonstrate how they can be applied as an integral part of spacecraft product assurance schemes, which involve quality, material and processes evaluations, and the selection of mechanical and component parts. In this successor edition, which has been revised and updated, engineering problems associated with critical spacecraft hardware and the space environment are highlighted by over 500 illustrations including micrographs and fractographs. Sp...

  14. Reliability assessment based on small samples of normal distribution

    International Nuclear Information System (INIS)

    Ma Zhibo; Zhu Jianshi; Xu Naixin

    2003-01-01

    When the pertinent parameter involved in reliability definition complies with normal distribution, the conjugate prior of its distributing parameters (μ, h) is of normal-gamma distribution. With the help of maximum entropy and the moments-equivalence principles, the subjective information of the parameter and the sampling data of its independent variables are transformed to a Bayesian prior of (μ,h). The desired estimates are obtained from either the prior or the posterior which is formed by combining the prior and sampling data. Computing methods are described and examples are presented to give demonstrations

  15. Physics of Failure as a Basis for Solder Elements Reliability Assessment in Wind Turbines

    DEFF Research Database (Denmark)

    Kostandyan, Erik; Sørensen, John Dalsgaard

    2012-01-01

    description of the reliability. A physics of failure approach is applied. A SnAg solder component used in power electronics is used as an example. Crack propagation in the SnAg solder is modeled and a model to assess the accumulated plastic strain is proposed based on a physics of failure approach. Based...... on the proposed model it is described how to find the accumulated linear damage and reliability levels for a given temperature loading profile. Using structural reliability methods the reliability levels of the electrical components are assessed by introducing scale factors for stresses....

  16. Practice of value-based distribution reliability assessment (VBDRA) at Scarborough Public Utilities

    International Nuclear Information System (INIS)

    Chen, R-L.

    1995-01-01

    The development of value-based distribution reliability assessment (VBDRA) at Scarborough Public Utilities was described. Load point reliability indices, customer interruption costs (CIC), continuity and service reliability, accuracy of CIC, and the aspects of application of VBDRA were addressed. The application of VBDRA to a long-term rebuild plan for 4.16 kV distribution system was described. The importance of a cost-benefit analysis for implementation of VBDRA was emphasized. In the case of the Scarborough Public Utilities Commission the enhanced feeder reliability assessment was found to influence the allocation of funding to where it provided the most value to customers. 14 refs., 3 tabs., 3 figs

  17. Cellular scanning strategy for selective laser melting: Generating reliable, optimized scanning paths and processing parameters

    DEFF Research Database (Denmark)

    Mohanty, Sankhya; Hattel, Jesper Henri

    2015-01-01

    method based uncertainty and reliability analysis. The reliability of the scanning paths are established using cumulative probability distribution functions for process output criteria such as sample density, thermal homogeneity, etc. A customized genetic algorithm is used along with the simulation model...

  18. Supporting change processes in design: Complexity, prediction and reliability

    Energy Technology Data Exchange (ETDEWEB)

    Eckert, Claudia M. [Engineering Design Centre, University of Cambridge, Trumpington Street, Cambridge, CB2 1PZ (United Kingdom)]. E-mail: cme26@cam.ac.uk; Keller, Rene [Engineering Design Centre, University of Cambridge, Trumpington Street, Cambridge, CB2 1PZ (United Kingdom)]. E-mail: rk313@cam.ac.uk; Earl, Chris [Open University, Department of Design and Innovation, Walton Hall, Milton Keynes MK7 6AA (United Kingdom)]. E-mail: C.F.Earl@open.ac.uk; Clarkson, P. John [Engineering Design Centre, University of Cambridge, Trumpington Street, Cambridge, CB2 1PZ (United Kingdom)]. E-mail: pjc10@cam.ac.uk

    2006-12-15

    Change to existing products is fundamental to design processes. New products are often designed through change or modification to existing products. Specific parts or subsystems are changed to similar ones whilst others are directly reused. Design by modification applies particularly to safety critical products where the reuse of existing working parts and subsystems can reduce cost and risk. However change is rarely a matter of just reusing or modifying parts. Changing one part can propagate through the entire design leading to costly rework or jeopardising the integrity of the whole product. This paper characterises product change based on studies in the aerospace and automotive industry and introduces tools to aid designers in understanding the potential effects of change. Two ways of supporting designers are described: probabilistic prediction of the effects of change and visualisation of change propagation through product connectivities. Change propagation has uncertainties which are amplified by the choices designers make in practice as they implement change. Change prediction and visualisation is discussed with reference to complexity in three areas of product development: the structural backcloth of connectivities in the existing product (and its processes), the descriptions of the product used in design and the actions taken to carry out changes.

  19. Reliability assessment of slender concrete columns at the stability failure

    Science.gov (United States)

    Valašík, Adrián; Benko, Vladimír; Strauss, Alfred; Täubling, Benjamin

    2018-01-01

    The European Standard for designing concrete columns within the use of non-linear methods shows deficiencies in terms of global reliability, in case that the concrete columns fail by the loss of stability. The buckling failure is a brittle failure which occurs without warning and the probability of its formation depends on the columns slenderness. Experiments with slender concrete columns were carried out in cooperation with STRABAG Bratislava LTD in Central Laboratory of Faculty of Civil Engineering SUT in Bratislava. The following article aims to compare the global reliability of slender concrete columns with slenderness of 90 and higher. The columns were designed according to methods offered by EN 1992-1-1 [1]. The mentioned experiments were used as basis for deterministic nonlinear modelling of the columns and subsequent the probabilistic evaluation of structural response variability. Final results may be utilized as thresholds for loading of produced structural elements and they aim to present probabilistic design as less conservative compared to classic partial safety factor based design and alternative ECOV method.

  20. Economic assessment of sterifeed process

    International Nuclear Information System (INIS)

    Mat Rasol Awang; Hassan Hamdani Mutaat

    2004-01-01

    The economics of a processing technology depends on its cost. Two types of costs commonly used in the estimation are a fixed cost and the other is variable cost. The cost structure that included in the fixed cost, mainly, the cost of land, building and machineries, and the variable cost covers raw materials, salary / wages, utilities, irradiation charge, other miscellaneous expenses and contingencies. The assessment were made by treating the economic data using discounted cash flow projection method to deduce the economic indicators: Net Present Value (NPV), Internal Rate of Return (IRR), Benefit to Cost (B/C) ratio, that would suggest the project feasibility, either feasible or otherwise. The NPV, IRR, B/C deduced from Sterifeed Process showed the economic of this technology was infeasible due high cost incurred in transportation, labour as well as the cost of machinery. This is accomplished by sensitivity test performed on these cost components. However, cost structure derived from Sterifeed Plant serves as a model cost structure for economic assessment in production of Sterifeed, a fermented ruminant feed, and to work further on the economic of the project. This paper discuss economic evaluation of Sterifeed process in different scenarios that carried out in the Sterifeed process operations and deduction were made to derive a model production unit for commercialisation. (Author)

  1. Electron backscatter diffraction: Strategies for reliable data acquisition and processing

    International Nuclear Information System (INIS)

    Randle, Valerie

    2009-01-01

    In electron backscatter diffraction (EBSD) software packages there are many user choices both in data acquisition and in data processing and display. In order to extract maximum scientific value from an inquiry, it is helpful to have some guidelines for best practice in conducting an EBSD investigation. The purpose of this article therefore is to address selected topics of EBSD practice, in a tutorial manner. The topics covered are a brief summary on the principles of EBSD, specimen preparation, calibration of an EBSD system, experiment design, speed of data acquisition, data clean-up, microstructure characterisation (including grain size) and grain boundary characterisation. This list is not meant to cover exhaustively all areas where EBSD is used, but rather to provide a resource consisting of some useful strategies for novice EBSD users.

  2. Uncertainty propagation and sensitivity analysis in system reliability assessment via unscented transformation

    International Nuclear Information System (INIS)

    Rocco Sanseverino, Claudio M.; Ramirez-Marquez, José Emmanuel

    2014-01-01

    The reliability of a system, notwithstanding it intended function, can be significantly affected by the uncertainty in the reliability estimate of the components that define the system. This paper implements the Unscented Transformation to quantify the effects of the uncertainty of component reliability through two approaches. The first approach is based on the concept of uncertainty propagation, which is the assessment of the effect that the variability of the component reliabilities produces on the variance of the system reliability. This assessment based on UT has been previously considered in the literature but only for system represented through series/parallel configuration. In this paper the assessment is extended to systems whose reliability cannot be represented through analytical expressions and require, for example, Monte Carlo Simulation. The second approach consists on the evaluation of the importance of components, i.e., the evaluation of the components that most contribute to the variance of the system reliability. An extension of the UT is proposed to evaluate the so called “main effects” of each component, as well to assess high order component interaction. Several examples with excellent results illustrate the proposed approach. - Highlights: • Simulation based approach for computing reliability estimates. • Computation of reliability variance via 2n+1 points. • Immediate computation of component importance. • Application to network systems

  3. The psychophysiological assessment method for pilot's professional reliability.

    Science.gov (United States)

    Zhang, L M; Yu, L S; Wang, K N; Jing, B S; Fang, C

    1997-05-01

    Previous research has shown that a pilot's professional reliability depends on two relative factors: the pilot's functional state and the demands of task workload. The Psychophysiological Reserve Capacity (PRC) is defined as a pilot's ability to accomplish additive tasks without reducing the performance of the primary task (flight task). We hypothesized that the PRC was a mirror of the pilot's functional state. The purpose of this study was to probe the psychophysiological method for evaluating a pilot's professional reliability on a simulator. The PRC Comprehensive Evaluating System (PRCCES) which was used in the experiment included four subsystems: a) quantitative evaluation system for pilot's performance on simulator; b) secondary task display and quantitative estimating system; c) multiphysiological data monitoring and statistical system; and d) comprehensive evaluation system for pilot PRC. Two studies were performed. In study one, 63 healthy and 13 hospitalized pilots participated. Each pilot performed a double 180 degrees circuit flight program with and without secondary task (three digit operation). The operator performance, score of secondary task and cost of physiological effort were measured and compared by PRCCES in the two conditions. Then, each pilot's flight skill in training was subjectively scored by instructor pilot ratings. In study two, 7 healthy pilots volunteered to take part in the experiment on the effects of sleep deprivation on pilot's PRC. Each participant had PRC tested pre- and post-8 h sleep deprivation. The results show that the PRC values of a healthy pilot was positively correlated with abilities of flexibility, operating and correcting deviation, attention distribution, and accuracy of instrument flight in the air (r = 0.27-0.40, p < 0.05), and negatively correlated with emotional anxiety in flight (r = -0.40, p < 0.05). The values of PRC in healthy pilots (0.61 +/- 0.17) were significantly higher than that of hospitalized pilots

  4. Reliability, precision, and measurement in the context of data from ability tests, surveys, and assessments

    International Nuclear Information System (INIS)

    Fisher, W P Jr; Elbaum, B; Coulter, A

    2010-01-01

    Reliability coefficients indicate the proportion of total variance attributable to differences among measures separated along a quantitative continuum by a testing, survey, or assessment instrument. Reliability is usually considered to be influenced by both the internal consistency of a data set and the number of items, though textbooks and research papers rarely evaluate the extent to which these factors independently affect the data in question. Probabilistic formulations of the requirements for unidimensional measurement separate consistency from error by modelling individual response processes instead of group-level variation. The utility of this separation is illustrated via analyses of small sets of simulated data, and of subsets of data from a 78-item survey of over 2,500 parents of children with disabilities. Measurement reliability ultimately concerns the structural invariance specified in models requiring sufficient statistics, parameter separation, unidimensionality, and other qualities that historically have made quantification simple, practical, and convenient for end users. The paper concludes with suggestions for a research program aimed at focusing measurement research more on the calibration and wide dissemination of tools applicable to individuals, and less on the statistical study of inter-variable relations in large data sets.

  5. Reliability and availability assessments for the next European Torus

    International Nuclear Information System (INIS)

    Bunde, R.

    1988-01-01

    To achieve its targets in reasonable time, the Next European Torus (NET) must be operated with considerable reliability and availability (R and A). Therefore, failure modes, effects, and criticality analysis (FMECA) of the overall plant and of its major components is already being performed as the design evolves. The present status of the R and A work is described in four steps: First, the R and A targets envisaged for the NET operation are discussed. Then an FMECA covering the overall plant is described, and a more detailed FMECA of major components is presented concerning the toroidal field coil systeml plasma heating systems; protection, instrumentation, and control systems; first wall and blanket, as well as the cooling system. Finally, the R and A results are compared with the targets, and measures for improvements are given

  6. Defect localization, characterization and reliability assessment in emerging photovoltaic devices.

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Benjamin Bing-Yeh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Cruz-Campa, Jose Luis [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Haase, Gad S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Tangyunyong, Paiboon [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Colr, Edward Isaac [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Okandan, Murat [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Nielson, Gregory N. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-04-01

    Microsystems-enabled photovoltaics (MEPV) can potentially meet increasing demands for light-weight, portable, photovoltaic solutions with high power density and efficiency. The study in this report examines failure analysis techniques to perform defect localization and evaluate MEPV modules. CMOS failure analysis techniques, including electroluminescence, light-induced voltage alteration, thermally-induced voltage alteration, optical beam induced current, and Seabeck effect imaging were successfully adapted to characterize MEPV modules. The relative advantages of each approach are reported. In addition, the effects of exposure to reverse bias and light stress are explored. MEPV was found to have good resistance to both kinds of stressors. The results form a basis for further development of failure analysis techniques for MEPVs of different materials systems or multijunction MEPVs. The incorporation of additional stress factors could be used to develop a reliability model to generate lifetime predictions for MEPVs as well as uncover opportunities for future design improvements.

  7. A Valid and Reliable Tool to Assess Nursing Students` Clinical Performance

    OpenAIRE

    Mehrnoosh Pazargadi; Tahereh Ashktorab; Sharareh Khosravi; Hamid Alavi majd

    2013-01-01

    Background: The necessity of a valid and reliable assessment tool is one of the most repeated issues in nursing students` clinical evaluation. But it is believed that present tools are not mostly valid and can not assess students` performance properly.Objectives: This study was conducted to design a valid and reliable assessment tool for evaluating nursing students` performance in clinical education.Methods: In this methodological study considering nursing students` performance definition; th...

  8. [A reliability growth assessment method and its application in the development of equipment in space cabin].

    Science.gov (United States)

    Chen, J D; Sun, H L

    1999-04-01

    Objective. To assess and predict reliability of an equipment dynamically by making full use of various test informations in the development of products. Method. A new reliability growth assessment method based on army material system analysis activity (AMSAA) model was developed. The method is composed of the AMSAA model and test data conversion technology. Result. The assessment and prediction results of a space-borne equipment conform to its expectations. Conclusion. It is suggested that this method should be further researched and popularized.

  9. Wind Farm Reliability Modelling Using Bayesian Networks and Semi-Markov Processes

    Directory of Open Access Journals (Sweden)

    Robert Adam Sobolewski

    2015-09-01

    Full Text Available Technical reliability plays an important role among factors affecting the power output of a wind farm. The reliability is determined by an internal collection grid topology and reliability of its electrical components, e.g. generators, transformers, cables, switch breakers, protective relays, and busbars. A wind farm reliability’s quantitative measure can be the probability distribution of combinations of operating and failed states of the farm’s wind turbines. The operating state of a wind turbine is its ability to generate power and to transfer it to an external power grid, which means the availability of the wind turbine and other equipment necessary for the power transfer to the external grid. This measure can be used for quantitative analysis of the impact of various wind farm topologies and the reliability of individual farm components on the farm reliability, and for determining the expected farm output power with consideration of the reliability. This knowledge may be useful in an analysis of power generation reliability in power systems. The paper presents probabilistic models that quantify the wind farm reliability taking into account the above-mentioned technical factors. To formulate the reliability models Bayesian networks and semi-Markov processes were used. Using Bayesian networks the wind farm structural reliability was mapped, as well as quantitative characteristics describing equipment reliability. To determine the characteristics semi-Markov processes were used. The paper presents an example calculation of: (i probability distribution of the combination of both operating and failed states of four wind turbines included in the wind farm, and (ii expected wind farm output power with consideration of its reliability.

  10. A heuristic-based approach for reliability importance assessment of energy producers

    International Nuclear Information System (INIS)

    Akhavein, A.; Fotuhi Firuzabad, M.

    2011-01-01

    Reliability of energy supply is one of the most important issues of service quality. On one hand, customers usually have different expectations for service reliability and price. On the other hand, providing different level of reliability at load points is a challenge for system operators. In order to take reasonable decisions and obviate reliability implementation difficulties, market players need to know impacts of their assets on system and load-point reliabilities. One tool to specify reliability impacts of assets is the criticality or reliability importance measure by which system components can be ranked based on their effect on reliability. Conventional methods for determination of reliability importance are essentially on the basis of risk sensitivity analysis and hence, impose prohibitive calculation burden in large power systems. An approach is proposed in this paper to determine reliability importance of energy producers from perspective of consumers or distribution companies in a composite generation and transmission system. In the presented method, while avoiding immense computational burden, the energy producers are ranked based on their rating, unavailability and impact on power flows in the lines connecting to the considered load points. Study results on the IEEE reliability test system show successful application of the proposed method. - Research highlights: → Required reliability level at load points is a concern in modern power systems. → It is important to assess reliability importance of energy producers or generators. → Generators can be ranked based on their impacts on power flow to a selected area. → Ranking of generators is an efficient tool to assess their reliability importance.

  11. DESIGN OF WATER-COOLED PACKAGED AIR-CONDITIONING SYSTEMS BASED ON RELIABILITY ASSESSMENT

    OpenAIRE

    関口, 圭輔; 中尾, 正喜; 藁谷, 至誠; 植草, 常雄; 羽山, 広文

    2007-01-01

    Water-cooled packaged air-conditioning systems are reevaluated in terms of alleviating the heat island phenomenon in cities and effectively utilizing building rooftops. Up to now, such reliability assessment has been insufficient, and this has limited the use of this kind of air-conditioning system in the information and communications sectors that demand a high reliability. This work has led to the development of a model for evaluating the reliability of water-cooled package air-conditioning...

  12. Incorporating travel-time reliability into the congestion management process : a primer.

    Science.gov (United States)

    2015-02-01

    This primer explains the value of incorporating travel-time reliability into the Congestion Management Process (CMP) : and identifies the most current tools available to assist with this effort. It draws from applied research and best practices : fro...

  13. Gamma processes and peaks-over-threshold distributions for time-dependent reliability

    International Nuclear Information System (INIS)

    Noortwijk, J.M. van; Weide, J.A.M. van der; Kallen, M.J.; Pandey, M.D.

    2007-01-01

    In the evaluation of structural reliability, a failure is defined as the event in which stress exceeds a resistance that is liable to deterioration. This paper presents a method to combine the two stochastic processes of deteriorating resistance and fluctuating load for computing the time-dependent reliability of a structural component. The deterioration process is modelled as a gamma process, which is a stochastic process with independent non-negative increments having a gamma distribution with identical scale parameter. The stochastic process of loads is generated by a Poisson process. The variability of the random loads is modelled by a peaks-over-threshold distribution (such as the generalised Pareto distribution). These stochastic processes of deterioration and load are combined to evaluate the time-dependent reliability

  14. Advanced Reactor PSA Methodologies for System Reliability Analysis and Source Term Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Grabaskas, D.; Brunett, A.; Passerini, S.; Grelle, A.; Bucknor, M.

    2017-06-26

    Beginning in 2015, a project was initiated to update and modernize the probabilistic safety assessment (PSA) of the GE-Hitachi PRISM sodium fast reactor. This project is a collaboration between GE-Hitachi and Argonne National Laboratory (Argonne), and funded in part by the U.S. Department of Energy. Specifically, the role of Argonne is to assess the reliability of passive safety systems, complete a mechanistic source term calculation, and provide component reliability estimates. The assessment of passive system reliability focused on the performance of the Reactor Vessel Auxiliary Cooling System (RVACS) and the inherent reactivity feedback mechanisms of the metal fuel core. The mechanistic source term assessment attempted to provide a sequence specific source term evaluation to quantify offsite consequences. Lastly, the reliability assessment focused on components specific to the sodium fast reactor, including electromagnetic pumps, intermediate heat exchangers, the steam generator, and sodium valves and piping.

  15. Process Waste Assessment - Paint Shop

    International Nuclear Information System (INIS)

    Phillips, N.M.

    1993-06-01

    This Process Waste Assessment was conducted to evaluate hazardous wastes generated in the Paint Shop, Building 913, Room 130. Special attention is given to waste streams generated by the spray painting process because it requires a number of steps for preparing, priming, and painting an object. Also, the spray paint booth covers the largest area in R-130. The largest and most costly waste stream to dispose of is open-quote Paint Shop wasteclose quotes -- a combination of paint cans, rags, sticks, filters, and paper containers. These items are compacted in 55-gallon drums and disposed of as solid hazardous waste. Recommendations are made for minimizing waste in the Paint Shop. Paint Shop personnel are very aware of the need to minimize hazardous wastes and are continuously looking for opportunities to do so

  16. Service reliability assessment using failure mode and effect analysis ...

    African Journals Online (AJOL)

    user

    Statistical Process Control Teng and Ho (1996) .... are still remaining left on modelling the interaction between impact of internal service failure and ..... Design error proofing: development of automated error-proofing information systems, Proceedings of.

  17. Surgeon Reliability for the Assessment of Lumbar Spinal Stenosis on MRI: The Impact of Surgeon Experience.

    Science.gov (United States)

    Marawar, Satyajit V; Madom, Ian A; Palumbo, Mark; Tallarico, Richard A; Ordway, Nathaniel R; Metkar, Umesh; Wang, Dongliang; Green, Adam; Lavelle, William F

    2017-01-01

    Treating surgeon's visual assessment of axial MRI images to ascertain the degree of stenosis has a critical impact on surgical decision-making. The purpose of this study was to prospectively analyze the impact of surgeon experience on inter-observer and intra-observer reliability of assessing severity of spinal stenosis on MRIs by spine surgeons directly involved in surgical decision-making. Seven fellowship trained spine surgeons reviewed MRI studies of 30 symptomatic patients with lumbar stenosis and graded the stenosis in the central canal, the lateral recess and the foramen at T12-L1 to L5-S1 as none, mild, moderate or severe. No specific instructions were provided to what constituted mild, moderate, or severe stenosis. Two surgeons were "senior" (>fifteen years of practice experience); two were "intermediate" (>four years of practice experience), and three "junior" (< one year of practice experience). The concordance correlation coefficient (CCC) was calculated to assess inter-observer reliability. Seven MRI studies were duplicated and randomly re-read to evaluate inter-observer reliability. Surgeon experience was found to be a strong predictor of inter-observer reliability. Senior inter-observer reliability was significantly higher assessing central(p<0.001), foraminal p=0.005 and lateral p=0.001 than "junior" group.Senior group also showed significantly higher inter-observer reliability that intermediate group assessing foraminal stenosis (p=0.036). In intra-observer reliability the results were contrary to that found in inter-observer reliability. Inter-observer reliability of assessing stenosis on MRIs increases with surgeon experience. Lower intra-observer reliability values among the senior group, although not clearly explained, may be due to the small number of MRIs evaluated and quality of MRI images.Level of evidence: Level 3.

  18. Standardization of domestic human reliability analysis and experience of human reliability analysis in probabilistic safety assessment for NPPs under design

    International Nuclear Information System (INIS)

    Kang, D. I.; Jung, W. D.

    2002-01-01

    This paper introduces the background and development activities of domestic standardization of procedure and method for Human Reliability Analysis (HRA) to avoid the intervention of subjectivity by HRA analyst in Probabilistic Safety Assessment (PSA) as possible, and the review of the HRA results for domestic nuclear power plants under design studied by Korea Atomic Energy Research Institute. We identify the HRA methods used for PSA for domestic NPPs and discuss the subjectivity of HRA analyst shown in performing a HRA. Also, we introduce the PSA guidelines published in USA and review the HRA results based on them. We propose the system of a standard procedure and method for HRA to be developed

  19. Frame-of-Reference Training: Establishing Reliable Assessment of Teaching Effectiveness.

    Science.gov (United States)

    Newman, Lori R; Brodsky, Dara; Jones, Richard N; Schwartzstein, Richard M; Atkins, Katharyn Meredith; Roberts, David H

    2016-01-01

    Frame-of-reference (FOR) training has been used successfully to teach faculty how to produce accurate and reliable workplace-based ratings when assessing a performance. We engaged 21 Harvard Medical School faculty members in our pilot and implementation studies to determine the effectiveness of using FOR training to assess health professionals' teaching performances. All faculty were novices at rating their peers' teaching effectiveness. Before FOR training, we asked participants to evaluate a recorded lecture using a criterion-based peer assessment of medical lecturing instrument. At the start of training, we discussed the instrument and emphasized its precise behavioral standards. During training, participants practiced rating lectures and received immediate feedback on how well they categorized and scored performances as compared with expert-derived scores of the same lectures. At the conclusion of the training, we asked participants to rate a post-training recorded lecture to determine agreement with the experts' scores. Participants and experts had greater rating agreement for the post-training lecture compared with the pretraining lecture. Through this investigation, we determined that FOR training is a feasible method to teach faculty how to accurately and reliably assess medical lectures. Medical school instructors and continuing education presenters should have the opportunity to be observed and receive feedback from trained peer observers. Our results show that it is possible to use FOR rater training to teach peer observers how to accurately rate medical lectures. The process is time efficient and offers the prospect for assessment and feedback beyond traditional learner evaluation of instruction.

  20. Reliability and Validity of the Research Methods Skills Assessment

    Science.gov (United States)

    Smith, Tamarah; Smith, Samantha

    2018-01-01

    The Research Methods Skills Assessment (RMSA) was created to measure psychology majors' statistics knowledge and skills. The American Psychological Association's Guidelines for the Undergraduate Major in Psychology (APA, 2007, 2013) served as a framework for development. Results from a Rasch analysis with data from n = 330 undergraduates showed…

  1. Reliability of dune erosion assessment along curved coastlines

    NARCIS (Netherlands)

    Hoonhout, B.M.; Den Heijer, C.

    2010-01-01

    The dune assessment methods used to ensure the safety of the lower areas in The Netherlands are based on simple empirical relations that are, strictly speaking, only valid for infinitely long, uniform and straight coasts. The wide application of these relations is mainly justified due to intentional

  2. reliability reliability

    African Journals Online (AJOL)

    eobe

    Corresponding author, Tel: +234-703. RELIABILITY .... V , , given by the code of practice. However, checks must .... an optimization procedure over the failure domain F corresponding .... of Concrete Members based on Utility Theory,. Technical ...

  3. Reliability of the ECHOWS Tool for Assessment of Patient Interviewing Skills.

    Science.gov (United States)

    Boissonnault, Jill S; Evans, Kerrie; Tuttle, Neil; Hetzel, Scott J; Boissonnault, William G

    2016-04-01

    History taking is an important component of patient/client management. Assessment of student history-taking competency can be achieved via a standardized tool. The ECHOWS tool has been shown to be valid with modest intrarater reliability in a previous study but did not demonstrate sufficient power to definitively prove its stability. The purposes of this study were: (1) to assess the reliability of the ECHOWS tool for student assessment of patient interviewing skills and (2) to determine whether the tool discerns between novice and experienced skill levels. A reliability and construct validity assessment was conducted. Three faculty members from the United States and Australia scored videotaped histories from standardized patients taken by students and experienced clinicians from each of these countries. The tapes were scored twice, 3 to 6 weeks apart. Reliability was assessed using interclass correlation coefficients (ICCs) and repeated measures. Analysis of variance models assessed the ability of the tool to discern between novice and experienced skill levels. The ECHOWS tool showed excellent intrarater reliability (ICC [3,1]=.74-.89) and good interrater reliability (ICC [2,1]=.55) as a whole. The summary of performance (S) section showed poor interrater reliability (ICC [2,1]=.27). There was no statistical difference in performance on the tool between novice and experienced clinicians. A possible ceiling effect may occur when standardized patients are not coached to provide complex and obtuse responses to interviewer questions. Variation in familiarity with the ECHOWS tool and in use of the online training may have influenced scoring of the S section. The ECHOWS tool demonstrates excellent intrarater reliability and moderate interrater reliability. Sufficient training with the tool prior to student assessment is recommended. The S section must evolve in order to provide a more discerning measure of interviewing skills. © 2016 American Physical Therapy

  4. Reliability of joint count assessment in rheumatoid arthritis: a systematic literature review.

    Science.gov (United States)

    Cheung, Peter P; Gossec, Laure; Mak, Anselm; March, Lyn

    2014-06-01

    Joint counts are central to the assessment of rheumatoid arthritis (RA) but reliability is an issue. To evaluate the reliability and agreement of joint counts (intra-observer and inter-observer) by health care professionals (physicians, nurses, and metrologists) and patients in RA, and the impact of training and standardization on joint count reliability through a systematic literature review. Articles reporting joint count reliability or agreement in RA in PubMed, EMBase, and the Cochrane library between 1960 and 2012 were selected. Data were extracted regarding tender joint counts (TJCs) and swollen joint counts (SJCs) derived by physicians, metrologists, or patients for intra-observer and inter-observer reliability. In addition, methods and effects of training or standardization were extracted. Statistics expressing reliability such as intraclass correlation coefficients (ICCs) were extracted. Data analysis was primarily descriptive due to high heterogeneity. Twenty-eight studies on health care professionals (HCP) and 20 studies on patients were included. Intra-observer reliability for TJCs and SJCs was good for HCPs and patients (range of ICC: 0.49-0.98). Inter-observer reliability between HCPs for TJCs was higher than for SJCs (range of ICC: 0.64-0.88 vs. 0.29-0.98). Patient inter-observer reliability with HCPs as comparators was better for TJCs (range of ICC: 0.31-0.91) compared to SJCs (0.16-0.64). Nine studies (7 with HCPs and 2 with patients) evaluated consensus or training, with improvement in reliability of TJCs but conflicting evidence for SJCs. Intra- and inter-observer reliability was high for TJCs for HCPs and patients: among all groups, reliability was better for TJCs than SJCs. Inter-observer reliability of SJCs was poorer for patients than HCPs. Data were inconclusive regarding the potential for training to improve SJC reliability. Overall, the results support further evaluation for patient-reported joint counts as an outcome measure. © 2013

  5. Reliability and validity of a nutrition and physical activity environmental self-assessment for child care

    Directory of Open Access Journals (Sweden)

    Ammerman Alice S

    2007-07-01

    Full Text Available Abstract Background Few assessment instruments have examined the nutrition and physical activity environments in child care, and none are self-administered. Given the emerging focus on child care settings as a target for intervention, a valid and reliable measure of the nutrition and physical activity environment is needed. Methods To measure inter-rater reliability, 59 child care center directors and 109 staff completed the self-assessment concurrently, but independently. Three weeks later, a repeat self-assessment was completed by a sub-sample of 38 directors to assess test-retest reliability. To assess criterion validity, a researcher-administered environmental assessment was conducted at 69 centers and was compared to a self-assessment completed by the director. A weighted kappa test statistic and percent agreement were calculated to assess agreement for each question on the self-assessment. Results For inter-rater reliability, kappa statistics ranged from 0.20 to 1.00 across all questions. Test-retest reliability of the self-assessment yielded kappa statistics that ranged from 0.07 to 1.00. The inter-quartile kappa statistic ranges for inter-rater and test-retest reliability were 0.45 to 0.63 and 0.27 to 0.45, respectively. When percent agreement was calculated, questions ranged from 52.6% to 100% for inter-rater reliability and 34.3% to 100% for test-retest reliability. Kappa statistics for validity ranged from -0.01 to 0.79, with an inter-quartile range of 0.08 to 0.34. Percent agreement for validity ranged from 12.9% to 93.7%. Conclusion This study provides estimates of criterion validity, inter-rater reliability and test-retest reliability for an environmental nutrition and physical activity self-assessment instrument for child care. Results indicate that the self-assessment is a stable and reasonably accurate instrument for use with child care interventions. We therefore recommend the Nutrition and Physical Activity Self-Assessment for

  6. Can we reliably benchmark health technology assessment organizations?

    Science.gov (United States)

    Drummond, Michael; Neumann, Peter; Jönsson, Bengt; Luce, Bryan; Schwartz, J Sanford; Siebert, Uwe; Sullivan, Sean D

    2012-04-01

    In recent years, there has been growth in the use of health technology assessment (HTA) for making decisions about the reimbursement, coverage, or guidance on the use of health technologies. Given this greater emphasis on the use of HTA, it is important to develop standards of good practice and to benchmark the various HTA organizations against these standards. This study discusses the conceptual and methodological challenges associated with benchmarking HTA organizations and proposes a series of audit questions based on a previously published set of principles of good practice. It is concluded that a benchmarking exercise would be feasible and useful, although the question of who should do the benchmarking requires further discussion. Key issues for further research are the alternative methods for weighting the various principles and for generating an overall score, or summary statement of adherence to the principles. Any weighting system, if developed, would need to be explored in different jurisdictions to assess the extent to which the relative importance of the principles is perceived to vary. Finally, the development and precise wording of the audit questions requires further study, with a view to making the questions as unambiguous as possible, and the reproducibility of the assessments as high as possible.

  7. Reliability of system identification techniques to assess standing balance in healthy elderly

    NARCIS (Netherlands)

    Pasma, Jantsje H.; Engelhart, Denise; Maier, Andrea B.; Aarts, Ronald G.K.M.; Van Gerven, Joop M.A.; Arendzen, J. Hans; Schouten, Alfred C.; Meskers, Carel G.M.; Van Kooij, Herman Der

    2016-01-01

    Objectives System identification techniques have the potential to assess the contribution of the underlying systems involved in standing balance by applying well-known disturbances. We investigated the reliability of standing balance parameters obtained with multivariate closed loop system

  8. Reliability of System Identification Techniques to Assess Standing Balance in Healthy Elderly

    NARCIS (Netherlands)

    Pasma, J.H.; Engelhart, D.; Maier, A.B.; Aarts, R.G.K.M.; Van Gerven, J.M.A.; Arendzen, J.H.; Schouten, A.C.; Meskers, C.G.M.; Van der Kooij, H.

    2016-01-01

    Objectives System identification techniques have the potential to assess the contribution of the underlying systems involved in standing balance by applying well-known disturbances. We investigated the reliability of standing balance parameters obtained with multivariate closed loop system

  9. Extracting information from an ensemble of GCMs to reliably assess future global runoff change

    NARCIS (Netherlands)

    Sperna Weiland, F.C.; Beek, L.P.H. van; Weerts, A.H.; Bierkens, M.F.P.

    2011-01-01

    Future runoff projections derived from different global climate models (GCMs) show large differences. Therefore, within this study the, information from multiple GCMs has been combined to better assess hydrological changes. For projections of precipitation and temperature the Reliability ensemble

  10. Clinical reliability and validity of elbow functional assessment in rheumatoid arthritis.

    NARCIS (Netherlands)

    Boer, Y.A. de; Ende, C.H.M. van den; Eygendaal, D.; Jolie, I.M.M.; Hazes, J.M.W.; Rozing, P.M.

    1999-01-01

    OBJECTIVES: (1) To investigate the measurement characteristics of the Hospital for Special Surgery (HSS) and Mayo Clinic elbow assessment instruments, utilizing methodological criteria including feasibility, reliability, validity, and discriminative ability; and (2) to develop an efficient and

  11. Reliability of voxel gray values in cone beam computed tomography for preoperative implant planning assessment

    NARCIS (Netherlands)

    Parsa, A.; Ibrahim, N.; Hassan, B.; Motroni, A.; van der Stelt, P.; Wismeijer, D.

    2012-01-01

    Purpose: To assess the reliability of cone beam computed tomography (CBCT) voxel gray value measurements using Hounsfield units (HU) derived from multislice computed tomography (MSCT) as a clinical reference (gold standard). Materials and Methods: Ten partially edentulous human mandibular cadavers

  12. Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment. Research project

    International Nuclear Information System (INIS)

    Martorell, S.; Serradell, V.; Munoz, A.; Sanchez, A.

    1997-01-01

    Background, objective, scope, detailed working plan and follow-up and final product of the project ''Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment'' are described

  13. Definition and Reliability Assessment of Elementary Ultrasonographic Findings in Calcium Pyrophosphate Deposition Disease

    DEFF Research Database (Denmark)

    Filippou, Georgios; Scirè, Carlo A; Damjanov, Nemanja

    2017-01-01

    OBJECTIVE: To define the ultrasonographic characteristics of calcium pyrophosphate crystal (CPP) deposits in joints and periarticular tissues and to evaluate the intra- and interobserver reliability of expert ultrasonographers in the assessment of CPP deposition disease (CPPD) according to the ne...

  14. A comparative study on the HW reliability assessment methods for digital I and C equipment

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hoan Sung; Sung, T. Y.; Eom, H. S.; Park, J. K.; Kang, H. G.; Lee, G. Y. [Korea Atomic Energy Research Institute, Taejeon (Korea); Kim, M. C. [Korea Advanced Institute of Science and Technology, Taejeon (Korea); Jun, S. T. [KHNP, Taejeon (Korea)

    2002-03-01

    It is necessary to predict or to evaluate the reliability of electronic equipment for the probabilistic safety analysis of digital instrument and control equipment. But most databases for the reliability prediction have no data for the up-to-date equipment and the failure modes are not classified. The prediction results for the specific component show different values according to the methods and databases. For boards and systems each method shows different values than others also. This study is for reliability prediction of PDC system for Wolsong NPP1 as a digital I and C equipment. Various reliability prediction methods and failure databases are used in calculation of the reliability to compare the effects of sensitivity and accuracy of each model and database. Many considerations for the reliability assessment of digital systems are derived with the results of this study. 14 refs., 19 figs., 15 tabs. (Author)

  15. Equipment reliability improvement process; implementation in Almaraz NPP and Trillo NPP

    International Nuclear Information System (INIS)

    Risquez Bailon, Aranzazu; Gutierrez Fernandez, Eduardo

    2010-01-01

    The Equipment Reliability Improvement Process (INPO AP-913) is a non-regulatory process developed by the US Nuclear Industry for improving Plants Availability. This Process integrates and coordinates a broad range of equipment reliability activities into one process, performed by the Plant in a non-centralized way. The integration and coordination of these activities will allow plant personnel to evaluate the trends of important station equipment, develop and implement long-term equipment health plans, monitor equipment performance and condition, and make adjustments to preventive maintenance tasks and frequencies based on equipment operating experience, if necessary, arbitrating operational and design improvements, to reach a Failure-free Operation. This paper describes the methodology of Equipment Reliability Improvement Process, being focused on main aspects of the implementation process, relating to the scope and establishment of an Equipment Reliability Monitoring Plan, which should include and complement the existing mechanisms and organizations in the Plant to monitor the condition and performance of the equipments, with the common aim of achieving an operation free of failures. The paper will describe the tools that Iberdrola Ingenieria has developed to support the implementation and monitoring of the Equipment Reliability Improvement Process, as well as the results and lessons learned from its implementation in Almaraz NPP and Trillo NPP. (authors)

  16. Inter- and intra- observer reliability of risk assessment of repetitive work without an explicit method.

    Science.gov (United States)

    Eliasson, Kristina; Palm, Peter; Nyman, Teresia; Forsman, Mikael

    2017-07-01

    A common way to conduct practical risk assessments is to observe a job and report the observed long term risks for musculoskeletal disorders. The aim of this study was to evaluate the inter- and intra-observer reliability of ergonomists' risk assessments without the support of an explicit risk assessment method. Twenty-one experienced ergonomists assessed the risk level (low, moderate, high risk) of eight upper body regions, as well as the global risk of 10 video recorded work tasks. Intra-observer reliability was assessed by having nine of the ergonomists repeat the procedure at least three weeks after the first assessment. The ergonomists made their risk assessment based on his/her experience and knowledge. The statistical parameters of reliability included agreement in %, kappa, linearly weighted kappa, intraclass correlation and Kendall's coefficient of concordance. The average inter-observer agreement of the global risk was 53% and the corresponding weighted kappa (K w ) was 0.32, indicating fair reliability. The intra-observer agreement was 61% and 0.41 (K w ). This study indicates that risk assessments of the upper body, without the use of an explicit observational method, have non-acceptable reliability. It is therefore recommended to use systematic risk assessment methods to a higher degree. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Validity and reliability of balance assessment software using the Nintendo Wii balance board: usability and validation.

    Science.gov (United States)

    Park, Dae-Sung; Lee, GyuChang

    2014-06-10

    A balance test provides important information such as the standard to judge an individual's functional recovery or make the prediction of falls. The development of a tool for a balance test that is inexpensive and widely available is needed, especially in clinical settings. The Wii Balance Board (WBB) is designed to test balance, but there is little software used in balance tests, and there are few studies on reliability and validity. Thus, we developed a balance assessment software using the Nintendo Wii Balance Board, investigated its reliability and validity, and compared it with a laboratory-grade force platform. Twenty healthy adults participated in our study. The participants participated in the test for inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with balance assessment software using the Nintendo Wii balance board and a laboratory-grade force platform. Data such as Center of Pressure (COP) path length and COP velocity were acquired from the assessment systems. The inter-rater reliability, the intra-rater reliability, and concurrent validity were analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement (SEM). The inter-rater reliability (ICC: 0.89-0.79, SEM in path length: 7.14-1.90, SEM in velocity: 0.74-0.07), intra-rater reliability (ICC: 0.92-0.70, SEM in path length: 7.59-2.04, SEM in velocity: 0.80-0.07), and concurrent validity (ICC: 0.87-0.73, SEM in path length: 5.94-0.32, SEM in velocity: 0.62-0.08) were high in terms of COP path length and COP velocity. The balance assessment software incorporating the Nintendo Wii balance board was used in our study and was found to be a reliable assessment device. In clinical settings, the device can be remarkably inexpensive, portable, and convenient for the balance assessment.

  18. Reliability-Based Performance Assessment of Damaged Ships

    Science.gov (United States)

    2006-10-01

    37OR.A 2 AceI 2 oce 3 3C7R Main Deck Plan View at 9.906 metre STAA T~SIc ACCa IC 111 tI RO MAO ’ 2 0004 M 3O m 3 STORES) me 3 1 002~s STOR1 PfIS PlnVIS...Vol. 15, pp.7 4 -9 3 . Kaplan , M. Benatar, M., Bentson, J., Achtarides, T.A. (1984). "Analysis and assessment of major uncertainties associated with

  19. The Reliability of In-Training Assessment when Performance Improvement Is Taken into Account

    Science.gov (United States)

    van Lohuizen, Mirjam T.; Kuks, Jan B. M.; van Hell, Elisabeth A.; Raat, A. N.; Stewart, Roy E.; Cohen-Schotanus, Janke

    2010-01-01

    During in-training assessment students are frequently assessed over a longer period of time and therefore it can be expected that their performance will improve. We studied whether there really is a measurable performance improvement when students are assessed over an extended period of time and how this improvement affects the reliability of the…

  20. Assessment of test-retest reliability and internal consistency of the Wisconsin Gait Scale in hemiparetic post-stroke patients

    Directory of Open Access Journals (Sweden)

    Guzik Agnieszka

    2016-09-01

    Full Text Available Introduction: A proper assessment of gait pattern is a significant aspect in planning the process of teaching gait in hemiparetic post-stroke patients. The Wisconsin Gait Scale (WGS is an observational tool for assessing post-stroke patients’ gait. The aim of the study was to assess test-retest reliability and internal consistency of the WGS and examine correlations between gait assessment made with the WGS and gait speed, Brunnström scale, Ashworth’s scale and the Barthel Index.

  1. Pipeline integrity model-a formative approach towards reliability and life assessment

    International Nuclear Information System (INIS)

    Sayed, A.M.; Jaffery, M.A.

    2005-01-01

    Pipe forms an integral part of transmission medium in oil and gas industry. This holds true for both upstream and downstream segments of this global energy business. With the aging of this asset base, emphasis on its operational aspects has been under immense considerations from the operators and regulators sides. Moreover, the milieu of information area and enhancement in global trade has lifted the barriers on means to forge forward towards better utilization of resources. This has resulted in optimized solutions as priority for business and technical manager's world over. There is a paradigm shift from mere development of 'smart materials' to 'low life cycle cost material'. The force inducing this change is a rationale one: the recovery of development costs is no more a problem in a global community; rather it is the pay-off time which matters most to the materials end users. This means that decision makers are not evaluating just the price offered but are keen to judge the entire life cycle cost of a product. The integrity of pipe are affected by factors such as corrosion, fatigue-crack growth, stress-corrosion cracking, and mechanical damage. Extensive research in the area of reliability and life assessment has been carried out. A number of models concerning with the reliability issues of pipes have been developed and are being used by a number of pipeline operators worldwide. Yet, it is emphasised that there are no substitute for sound engineering judgment and allowance for factors of safety. The ability of a laid down pipe network to transport the intended fluid under pre-defined conditions for the entire project envisaged life, is referred to the reliability of system. The reliability is built into the product through extensive benchmarking against industry standard codes. The process of pipes construction for oil and gas service is regulated through American Petroleum Institute's Specification for Line Pipe. Subsequently, specific programs have been

  2. Construct Validity and Reliability of Structured Assessment of endoVascular Expertise in a Simulated Setting

    DEFF Research Database (Denmark)

    Bech, B; Lönn, L; Falkenberg, M

    2011-01-01

    Objectives To study the construct validity and reliability of a novel endovascular global rating scale, Structured Assessment of endoVascular Expertise (SAVE). Design A Clinical, experimental study. Materials Twenty physicians with endovascular experiences ranging from complete novices to highly....... Validity was analysed by correlating experience with performance results. Reliability was analysed according to generalisability theory. Results The mean score on the 29 items of the SAVE scale correlated well with clinical experience (R = 0.84, P ... with clinical experience (R = -0.53, P validity and reliability of assessment with the SAVE scale was high when applied to performances in a simulation setting with advanced realism. No ceiling effect...

  3. Life cycle reliability assessment of new products—A Bayesian model updating approach

    International Nuclear Information System (INIS)

    Peng, Weiwen; Huang, Hong-Zhong; Li, Yanfeng; Zuo, Ming J.; Xie, Min

    2013-01-01

    The rapidly increasing pace and continuously evolving reliability requirements of new products have made life cycle reliability assessment of new products an imperative yet difficult work. While much work has been done to separately estimate reliability of new products in specific stages, a gap exists in carrying out life cycle reliability assessment throughout all life cycle stages. We present a Bayesian model updating approach (BMUA) for life cycle reliability assessment of new products. Novel features of this approach are the development of Bayesian information toolkits by separately including “reliability improvement factor” and “information fusion factor”, which allow the integration of subjective information in a specific life cycle stage and the transition of integrated information between adjacent life cycle stages. They lead to the unique characteristics of the BMUA in which information generated throughout life cycle stages are integrated coherently. To illustrate the approach, an application to the life cycle reliability assessment of a newly developed Gantry Machining Center is shown

  4. A task analysis-linked approach for integrating the human factor in reliability assessments of nuclear power plants

    International Nuclear Information System (INIS)

    Ryan, T.G.

    1988-01-01

    This paper describes an emerging Task Analysis-Linked Evaluation Technique (TALENT) for assessing the contributions of human error to nuclear power plant systems unreliability and risk. Techniques such as TALENT are emerging as a recognition that human error is a primary contributor to plant safety, however, it has been a peripheral consideration to data in plant reliability evaluations. TALENT also recognizes that involvement of persons with behavioral science expertise is required to support plant reliability and risk analyses. A number of state-of-knowledge human reliability analysis tools are also discussed which support the TALENT process. The core of TALENT is comprised of task, timeline and interface analysis data which provide the technology base for event and fault tree development, serve as criteria for selecting and evaluating performance shaping factors, and which provide a basis for auditing TALENT results. Finally, programs and case studies used to refine the TALENT process are described along with future research needs in the area. (author)

  5. Special Purpose Nuclear Reactor (5 MW) for Reliable Power at Remote Sites Assessment Report

    Energy Technology Data Exchange (ETDEWEB)

    Sterbentz, James William [Idaho National Lab. (INL), Idaho Falls, ID (United States). Nuclear Science and Technology Division; Werner, James Elmer [Idaho National Lab. (INL), Idaho Falls, ID (United States). Nuclear Science and Technology Division; McKellar, Michael George [Idaho National Lab. (INL), Idaho Falls, ID (United States). Nuclear Science and Technology Division; Hummel, Andrew John [Idaho National Lab. (INL), Idaho Falls, ID (United States). Nuclear Science and Technology Division; Kennedy, John Charles [Idaho National Lab. (INL), Idaho Falls, ID (United States). Nuclear Science and Technology Division; Wright, Richard Neil [Idaho National Lab. (INL), Idaho Falls, ID (United States). Nuclear Science and Technology Division; Biersdorf, John Michael [Idaho National Lab. (INL), Idaho Falls, ID (United States). Nuclear Science and Technology Division

    2017-04-01

    The Phenomena Identification and Ranking Table (PIRT) technique was conducted on the Special Purpose Reactor nuclear plant design. The PIRT is a structured process to identify safety-relevant/safety-significant phenomena and assess the importance and knowledge base by ranking the phenomena. The Special Purpose Reactor is currently in the conceptual design stage. The candidate reactor has a solid monolithic stainless steel core with an array of heat pipes and fuel pellets embedded in the monolith. The heat pipes are used to remove heat from the core using simple, reliable, and well-characterized physics (capillarity, boiling, and condensation). In the initial design, one heat exchanger is used for the working fluid that produces energy, and a second heat exchanger is used to remove decay heat in emergency or shutdown conditions. In addition, a power conversion cycle such as an open-air Brayton system is available as an option for power conversion and process heat. This report summarizes and documents the process and scope of the four PIRT reviews, noting the major activities and conclusions. The identified phenomena, analyses, rationales, and associated ratings are presented along with a summary of the findings from the four individual PIRTs, namely (1) Reactor Accident and Normal Operations, (2) Heat Pipes, (3) Materials, and (4) Power Conversion. The PIRT reports for these four major system areas evaluated are attached as appendixes to this report and provide considerably more detail about each assessment as well as a more complete listing of the phenomena that were evaluated.

  6. The reliability of three psoriasis assessment tools: Psoriasis area and severity index, body surface area and physician global assessment.

    Science.gov (United States)

    Bożek, Agnieszka; Reich, Adam

    2017-08-01

    A wide variety of psoriasis assessment tools have been proposed to evaluate the severity of psoriasis in clinical trials and daily practice. The most frequently used clinical instrument is the psoriasis area and severity index (PASI); however, none of the currently published severity scores used for psoriasis meets all the validation criteria required for an ideal score. The aim of this study was to compare and assess the reliability of 3 commonly used assessment instruments for psoriasis severity: the psoriasis area and severity index (PASI), body surface area (BSA) and physician global assessment (PGA). On the scoring day, 10 trained dermatologists evaluated 9 adult patients with plaque-type psoriasis using the PASI, BSA and PGA. All the subjects were assessed twice by each physician. Correlations between the assessments were analyzed using the Pearson correlation coefficient. Intra-class correlation coefficient (ICC) was calculated to analyze intra-rater reliability, and the coefficient of variation (CV) was used to assess inter-rater variability. Significant correlations were observed among the 3 scales in both assessments. In all 3 scales the ICCs were > 0.75, indicating high intra-rater reliability. The highest ICC was for the BSA (0.96) and the lowest one for the PGA (0.87). The CV for the PGA and PASI were 29.3 and 36.9, respectively, indicating moderate inter-rater variability. The CV for the BSA was 57.1, indicating high inter-rater variability. Comparing the PASI, PGA and BSA, it was shown that the PGA had the highest inter-rater reliability, whereas the BSA had the highest intra-rater reliability. The PASI showed intermediate values in terms of interand intra-rater reliability. None of the 3 assessment instruments showed a significant advantage over the other. A reliable assessment of psoriasis severity requires the use of several independent evaluations simultaneously.

  7. Assessment of human decision reliability - a case study

    International Nuclear Information System (INIS)

    Pyy, P

    1998-01-01

    In his discussion of this case study, the author indicates that human beings are not merely machines who use rules. Thus, more focus needs to be put on studying decision making situations and their contexts. Decision theory (both normative and descriptive) and contextual psychological approaches may offer tools to cope with operator decision making. Further an ideal decision space needs to be defined for operators. The case study specifically addressed a loss of feedwater scenario and the various operator decisions that were involved in that scenario. It was concluded from this particular study that there are significant differences in the crew decision behaviours that are not explained by process variables. Through use of evidence from simulator tests with expert judgement, an approach to estimate probabilities has been developed. The modelling approach presented in this discussion is an extension of current HRA paradigms, but a natural one since all human beings make decisions

  8. Systamatic approach to integration of a human reliability analysis into a NPP probabalistic risk assessment

    International Nuclear Information System (INIS)

    Fragola, J.R.

    1984-01-01

    This chapter describes the human reliability analysis tasks which were employed in the evaluation of the overall probability of an internal flood sequence and its consequences in terms of disabling vulnerable risk significant equipment. Topics considered include the problem familiarization process, the identification and classification of key human interactions, a human interaction review of potential initiators, a maintenance and operations review, human interaction identification, quantification model selection, the definition of operator-induced sequences, the quantification of specific human interactions, skill- and rule-based interactions, knowledge-based interactions, and the incorporation of human interaction-related events into the event tree structure. It is concluded that an integrated approach to the analysis of human interaction within the context of a Probabilistic Risk Assessment (PRA) is feasible

  9. Analysis of complete logical structures in system reliability assessment

    International Nuclear Information System (INIS)

    Amendola, A.; Clarotti, C.A.; Contini, S.; Spizzichino, F.

    1980-01-01

    The application field of the fault-tree techniques has been explored in order to assess whether the AND-OR structures covered all possible actual binary systems. This resulted in the identification of various situations requiring the complete AND-OR-NOT structures for their analysis. We do not use the term non-coherent for such cases, since the monotonicity or not of a structure function is not a characteristic of a system, but of the particular top event being examined. The report presents different examples of complete fault-trees, which can be examined according to different degrees of approximation. In fact, the exact analysis for the determination of the smallest irredundant bases is very time consuming and actually necessary only in some particular cases (multi-state systems, incidental situations). Therefore, together with the exact procedure, the report shows two different methods of logical analysis that permit the reduction of complete fault-trees to AND-OR structures. Moreover, it discusses the problems concerning the evaluation of the probability distribution of the time to first top event occurrence, once the hypothesis of structure function monotonicity is removed

  10. Inter-rater reliability of an observation-based ergonomics assessment checklist for office workers.

    Science.gov (United States)

    Pereira, Michelle Jessica; Straker, Leon Melville; Comans, Tracy Anne; Johnston, Venerina

    2016-12-01

    To establish the inter-rater reliability of an observation-based ergonomics assessment checklist for computer workers. A 37-item (38-item if a laptop was part of the workstation) comprehensive observational ergonomics assessment checklist comparable to government guidelines and up to date with empirical evidence was developed. Two trained practitioners assessed full-time office workers performing their usual computer-based work and evaluated the suitability of workstations used. Practitioners assessed each participant consecutively. The order of assessors was randomised, and the second assessor was blinded to the findings of the first. Unadjusted kappa coefficients between the raters were obtained for the overall checklist and subsections that were formed from question-items relevant to specific workstation equipment. Twenty-seven office workers were recruited. The inter-rater reliability between two trained practitioners achieved moderate to good reliability for all except one checklist component. This checklist has mostly moderate to good reliability between two trained practitioners. Practitioner Summary: This reliable ergonomics assessment checklist for computer workers was designed using accessible government guidelines and supplemented with up-to-date evidence. Employers in Queensland (Australia) can fulfil legislative requirements by using this reliable checklist to identify and subsequently address potential risk factors for work-related injury to provide a safe working environment.

  11. Test-retest reliability of Brazilian version of Memorial Symptom Assessment Scale for assessing symptoms in cancer patients.

    Science.gov (United States)

    Menezes, Josiane Roberta de; Luvisaro, Bianca Maria Oliveira; Rodrigues, Claudia Fernandes; Muzi, Camila Drumond; Guimarães, Raphael Mendonça

    2017-01-01

    To assess the test-retest reliability of the Memorial Symptom Assessment Scale translated and culturally adapted into Brazilian Portuguese. The scale was applied in an interview format for 190 patients with various cancers type hospitalized in clinical and surgical sectors of the Instituto Nacional de Câncer José de Alencar Gomes da Silva and reapplied in 58 patients. Data from the test-retest were double typed into a Microsoft Excel spreadsheet and analyzed by the weighted Kappa. The reliability of the scale was satisfactory in test-retest. The weighted Kappa values obtained for each scale item had to be adequate, the largest item was 0.96 and the lowest was 0.69. The Kappa subscale was also evaluated and values were 0.84 for high frequency physic symptoms, 0.81 for low frequency physical symptoms, 0.81 for psychological symptoms, and 0.78 for Global Distress Index. High level of reliability estimated suggests that the process of measurement of Memorial Symptom Assessment Scale aspects was adequate. Avaliar a confiabilidade teste-reteste da versão traduzida e adaptada culturalmente para o português do Brasil do Memorial Symptom Assessment Scale. A escala foi aplicada em forma de entrevista em 190 pacientes com diversos tipos de câncer internados nos setores clínicos e cirúrgicos do Instituto Nacional de Câncer José de Alencar Gomes da Silva e reaplicada em 58 pacientes. Os dados dos testes-retestes foram inseridos num banco de dados por dupla digitação independente em Excel e analisados pelo Kappa ponderado. A confiabilidade da escala mostrou-se satisfatória nos testes-retestes. Os valores do Kappa ponderado obtidos para cada item da escala apresentaram-se adequados, sendo o maior item de 0,96 e o menor de 0,69. Também se avaliou o Kappa das subescalas, sendo de 0,84 para sintomas físicos de alta frequência, de 0,81 para sintomas físicos de baixa frequência, de 0,81 também para sintomas psicológicos, e de 0,78 para Índice Geral de Sofrimento

  12. Reliability and validity of the German version of the Utrecht Questionnaire for Outcome Assessment in Aesthetic Rhinoplasty (D-OAR).

    Science.gov (United States)

    Spiekermann, Christoph; Rudack, Claudia; Stenner, Markus

    2017-11-01

    The outcome of aesthetic rhinoplasty is determined by the patient's subjective satisfaction with the nasal appearance which is difficult to assess. The Utrecht Questionnaire for Outcome Assessment in Aesthetic Rhinoplasty (OAR) is a brief and reliable instrument to assess the influence of the subjective nasal appearance on quality of life in patients undergoing aesthetic rhinoplasty. Preoperative application of this questionnaire reveals important aspects and possible disturbances of the body image which could be negative predictors concerning the result. On the other hand, it represents an appropriate tool to assess the postoperative outcome. The aim of this study was to determine the validity, reliability and responsiveness of the adapted German version of the OAR (D-OAR). The adaption of the OAR to German language was performed by a forward and backward translation process. Patients undergoing rhinoplasty were asked to complete the D-OAR preoperatively, 1, 3 and 12 months after procedure and healthy volunteers without any nasal complaints served as controls to test validity, reliability and responsiveness. An excellent internal consistency, a good test-retest reliability and good inter-item and item-total correlations demonstrated a good reliability of the D-OAR. The convincing validity of the adapted version was proven by an excellent discriminant and a sufficient content validity. Significant differences between pre- and postoperative D-OAR scores revealed a good responsiveness of the instrument. Hence, with a sufficient validity, reliability and sensitivity to changes, the D-OAR is a short and helpful instrument to assess the subjective perception of the nasal appearance in German patients.

  13. Application of expert elicitation techniques in human reliability, assessment

    International Nuclear Information System (INIS)

    Sanyasi Rao, V.V.S.; Saraf, R.K.; Ghosh, A.K.; Kushwaha, H.S.

    2006-01-01

    Expert elicitation techniques are being used, in the area of technological forecasting, in estimating data needed for analysis when it is either difficult to arrive at the data by experimental means or when it is quite involved to plan and conduct the experiment. In this study, expert elicitation techniques are applied to the evaluation of the frequencies of the various accident sequences that can result from the initiating event (IE) 'High Pressure Process Water (HPPW) system failure' in typical Indian Pressurised Heavy Water Reactor (IPHWR) of the older generation. The Operating Procedure under Emergency Conditions (OPEC) for this IE involves human actions according to a pre-defined procedure. The Human Error Probabilities for all these human actions are obtained using expert elicitation techniques. These techniques aim at eliciting the opinion of the experts in the area of interest with regard to the issue in question. The uncertainty is analysed by employing the measure of dissonance and the most probable range of human error probabilities are arrived at by maximizing this measure. These values are combined using the same procedures mentioned above to yield a distribution representing the uncertainty associated with the predictions. (author)

  14. Assessing intraindividual variability in sustained attention: reliability, relation to speed and accuracy, and practice effects

    Directory of Open Access Journals (Sweden)

    HAGEN C. FLEHMIG

    2007-06-01

    Full Text Available We investigated the psychometric properties of competing measures of sustained attention. 179 subjects were assessed twice within seven day's time with a test designed to measure sustained attention, or concentration, respectively. In addition to traditional performance indices [i.e., speed (MRT and accuracy (E%], we evaluated two intraindividual response time (RT variability measures: standard deviation (SDRT and coefficient of variation (CVRT. For the overall test, both indices were reliable. SDRT showed good to acceptable retest reliability for all subtests. For CVRT, retest reliability coefficients ranged from very good to not satisfactory. While the reversed-word recognition test proved highly reliable, the mental calculation test and the arrows test were not sufficiently reliable. CVRT was only slightly correlated but SDRT was highly correlated with MRT. In contrast to substantial practice gains for MRT, SDRT and E%, only CVRT proved to be stable. In conclusion, CVRT appears to be a potential index for assessing performance variability: it is reliable for the overall test, only moderately correlated with speed, and virtually not affected by practice. However, before applying CVRT in practical assessment settings, additional research is required to elucidate the impact of task-specific factors on the reliability of this performance measure.

  15. Critical Assessment of the Foundations of Power Transmission and Distribution Reliability Metrics and Standards.

    Science.gov (United States)

    Nateghi, Roshanak; Guikema, Seth D; Wu, Yue Grace; Bruss, C Bayan

    2016-01-01

    The U.S. federal government regulates the reliability of bulk power systems, while the reliability of power distribution systems is regulated at a state level. In this article, we review the history of regulating electric service reliability and study the existing reliability metrics, indices, and standards for power transmission and distribution networks. We assess the foundations of the reliability standards and metrics, discuss how they are applied to outages caused by large exogenous disturbances such as natural disasters, and investigate whether the standards adequately internalize the impacts of these events. Our reflections shed light on how existing standards conceptualize reliability, question the basis for treating large-scale hazard-induced outages differently from normal daily outages, and discuss whether this conceptualization maps well onto customer expectations. We show that the risk indices for transmission systems used in regulating power system reliability do not adequately capture the risks that transmission systems are prone to, particularly when it comes to low-probability high-impact events. We also point out several shortcomings associated with the way in which regulators require utilities to calculate and report distribution system reliability indices. We offer several recommendations for improving the conceptualization of reliability metrics and standards. We conclude that while the approaches taken in reliability standards have made considerable advances in enhancing the reliability of power systems and may be logical from a utility perspective during normal operation, existing standards do not provide a sufficient incentive structure for the utilities to adequately ensure high levels of reliability for end-users, particularly during large-scale events. © 2015 Society for Risk Analysis.

  16. Clinical assessment of scapular positioning in musicians: an intertester reliability study.

    Science.gov (United States)

    Struyf, Filip; Nijs, Jo; De Coninck, Kris; Giunta, Marco; Mottram, Sarah; Meeusen, Romain

    2009-01-01

    The reliability of the measurement of the distance between the posterior border of the acromion and the wall and the reliability of the modified lateral scapular slide test have not been studied. Overall, the reliability of the clinical tools used to assess scapular positioning has not been studied in musicians. To examine the intertester reliability of scapular observation and 2 clinical tests for the assessment of scapular positioning in musicians. Intertester reliability study. University research laboratory. Thirty healthy student musicians at a single university. Two assessors performed a standardized observation protocol, the measurement of the distance between the posterior border of the acromion and the wall, and the modified lateral scapular slide test. Each assessor was blinded to the other's findings. The intertester reliability coefficients (kappa) for the observation in relaxed position, during unloaded movement, and during loaded movement were 0.41, 0.63, and 0.36, respectively. The kappa values for the observation of tilting and winging at rest were 0.48 and 0.42, respectively; during unloaded movement, the kappa values were 0.52 and 0.78, respectively; and with a 1-kg load, the kappa values were 0.24 and 0.50, respectively. The intraclass correlation coefficient (ICC) of the measurement of the acromial distance was 0.72 in relaxed position and 0.75 with the participant actively retracting both shoulders. The ICCs for the modified lateral scapular slide test varied between 0.63 and 0.58. Our results demonstrated that the modified lateral scapular slide test was not a reliable tool to assess scapular positioning in these participants. Our data indicated that scapular observation in the relaxed position and during unloaded abduction in the frontal plane was a reliable assessment tool. The reliability of the measurement of the distance between the posterior border of the acromion and the wall in healthy musicians was moderate.

  17. Empirical evaluation of the Process Overview Measure for assessing situation awareness in process plants.

    Science.gov (United States)

    Lau, Nathan; Jamieson, Greg A; Skraaning, Gyrd

    2016-03-01

    The Process Overview Measure is a query-based measure developed to assess operator situation awareness (SA) from monitoring process plants. A companion paper describes how the measure has been developed according to process plant properties and operator cognitive work. The Process Overview Measure demonstrated practicality, sensitivity, validity and reliability in two full-scope simulator experiments investigating dramatically different operational concepts. Practicality was assessed based on qualitative feedback of participants and researchers. The Process Overview Measure demonstrated sensitivity and validity by revealing significant effects of experimental manipulations that corroborated with other empirical results. The measure also demonstrated adequate inter-rater reliability and practicality for measuring SA in full-scope simulator settings based on data collected on process experts. Thus, full-scope simulator studies can employ the Process Overview Measure to reveal the impact of new control room technology and operational concepts on monitoring process plants. Practitioner Summary: The Process Overview Measure is a query-based measure that demonstrated practicality, sensitivity, validity and reliability for assessing operator situation awareness (SA) from monitoring process plants in representative settings.

  18. Lucky Belief in Science Education - Gettier Cases and the Value of Reliable Belief-Forming Processes

    Science.gov (United States)

    Brock, Richard

    2018-05-01

    The conceptualisation of knowledge as justified true belief has been shown to be, at the very least, an incomplete account. One challenge to the justified true belief model arises from the proposition of situations in which a person possesses a belief that is both justified and true which some philosophers intuit should not be classified as knowledge. Though situations of this type have been imagined by a number of writers, they have come to be labelled Gettier cases. Gettier cases arise when a fallible justification happens to lead to a true belief in one context, a case of `lucky belief'. In this article, it is argued that students studying science may make claims that resemble Gettier cases. In some contexts, a student may make a claim that is both justified and true but which arises from an alternative conception of a scientific concept. A number of instances of lucky belief in topics in science education are considered leading to an examination of the criteria teachers use to assess students' claims in different contexts. The possibility of lucky belief leads to the proposal that, in addition to the acquisition of justified true beliefs, the development of reliable belief-forming processes is a significant goal of science education. The pedagogic value of various kinds of claims is considered and, it is argued, the criteria used to judge claims may be adjusted to suit the context of assessment. It is suggested that teachers should be alert to instances of lucky belief that mask alternative conceptions.

  19. Reliability of fully automated versus visually controlled pre- and post-processing of resting-state EEG.

    Science.gov (United States)

    Hatz, F; Hardmeier, M; Bousleiman, H; Rüegg, S; Schindler, C; Fuhr, P

    2015-02-01

    To compare the reliability of a newly developed Matlab® toolbox for the fully automated, pre- and post-processing of resting state EEG (automated analysis, AA) with the reliability of analysis involving visually controlled pre- and post-processing (VA). 34 healthy volunteers (age: median 38.2 (20-49), 82% female) had three consecutive 256-channel resting-state EEG at one year intervals. Results of frequency analysis of AA and VA were compared with Pearson correlation coefficients, and reliability over time was assessed with intraclass correlation coefficients (ICC). Mean correlation coefficient between AA and VA was 0.94±0.07, mean ICC for AA 0.83±0.05 and for VA 0.84±0.07. AA and VA yield very similar results for spectral EEG analysis and are equally reliable. AA is less time-consuming, completely standardized, and independent of raters and their training. Automated processing of EEG facilitates workflow in quantitative EEG analysis. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  20. Review of Software Reliability Assessment Methodologies for Digital I and C Software of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jae Hyun; Lee, Seung Jun; Jung, Won Dea [KAERI, Daejeon (Korea, Republic of)

    2014-08-15

    Digital instrumentation and control (I and C) systems are increasingly being applied to current nuclear power plants (NPPs) due to its advantages; zero drift, advanced data calculation capacity, and design flexibility. Accordingly, safety issues of software that is main part of the digital I and C system have been raised. As with hardware components, the software failure in NPPs could lead to a large disaster, therefore failure rate test and reliability assessment of software should be properly performed, and after that adopted in NPPs. However, the reliability assessment of the software is quite different with that of hardware, owing to the nature difference between software and hardware. The one of the most different thing is that the software failures arising from design faults as 'error crystal', whereas the hardware failures are caused by deficiencies in design, production, and maintenance. For this reason, software reliability assessment has been focused on the optimal release time considering the economy. However, the safety goal and public acceptance of the NPPs is so distinctive with other industries that the software in NPPs is dependent on reliability quantitative value rather than economy. The safety goal of NPPs compared to other industries is exceptionally high, so conventional methodologies on software reliability assessment already used in other industries could not adjust to safety goal of NPPs. Thus, the new reliability assessment methodology of the software of digital I and C on NPPs need to be developed. In this paper, existing software reliability assessment methodologies are reviewed to obtain the pros and cons of them, and then to assess the usefulness of each method to software of NPPs.

  1. Review of Software Reliability Assessment Methodologies for Digital I and C Software of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Cho, Jae Hyun; Lee, Seung Jun; Jung, Won Dea

    2014-01-01

    Digital instrumentation and control (I and C) systems are increasingly being applied to current nuclear power plants (NPPs) due to its advantages; zero drift, advanced data calculation capacity, and design flexibility. Accordingly, safety issues of software that is main part of the digital I and C system have been raised. As with hardware components, the software failure in NPPs could lead to a large disaster, therefore failure rate test and reliability assessment of software should be properly performed, and after that adopted in NPPs. However, the reliability assessment of the software is quite different with that of hardware, owing to the nature difference between software and hardware. The one of the most different thing is that the software failures arising from design faults as 'error crystal', whereas the hardware failures are caused by deficiencies in design, production, and maintenance. For this reason, software reliability assessment has been focused on the optimal release time considering the economy. However, the safety goal and public acceptance of the NPPs is so distinctive with other industries that the software in NPPs is dependent on reliability quantitative value rather than economy. The safety goal of NPPs compared to other industries is exceptionally high, so conventional methodologies on software reliability assessment already used in other industries could not adjust to safety goal of NPPs. Thus, the new reliability assessment methodology of the software of digital I and C on NPPs need to be developed. In this paper, existing software reliability assessment methodologies are reviewed to obtain the pros and cons of them, and then to assess the usefulness of each method to software of NPPs

  2. Reliability and Validity of the Greek Migraine Disability Assessment (MIDAS) Questionnaire.

    Science.gov (United States)

    Oikonomidi, Theodora; Vikelis, Michail; Artemiadis, Artemios; Chrousos, George P; Darviri, Christina

    2018-03-01

    The Migraine Disability Assessment (MIDAS) Questionnaire is a reliable and valid instrument for migraine-related disability. Such a tool is needed to quantify migraine-related disability in the Greek population. This validation study aims to assess the test-retest reliability, internal consistency, item discriminant and convergent validity of the Greek translation of the MIDAS. Adults diagnosed with migraine completed the MIDAS Questionnaire on two occasions 3 weeks apart to assess reliability, and completed the RAND-36 to assess validity. Participants (n = 152) had a median MIDAS score of 24 and mostly severe disability (58% were grade IV). The test-retest reliability analysis (N = 59) revealed excellent reliability for the total score. Internal consistency was α = 0.71 for initial and α = 0.82 for retest completion. For item discriminant validity, the correlations between each question and the total score were significant, with high correlations for questions 2-5 (range 0.67 ≤ r ≤ 0.79; p MIDAS score tended to have better wellbeing. Psychometric properties are comparable with those of other published validation studies of the MIDAS and the original. Findings on question 1 show that missing work/school days may be closely related with increased affect issues. The Greek version of the MIDAS Questionnaire has good reliability and validity. This study allowed for cross-cultural comparability of research findings.

  3. Assessment of Advanced Life Support competence when combining different test methods--reliability and validity

    DEFF Research Database (Denmark)

    Ringsted, C; Lippert, F; Hesselfeldt, R

    2007-01-01

    Cardiac Arrest Simulation Test (CASTest) scenarios for the assessments according to guidelines 2005. AIMS: To analyse the reliability and validity of the individual sub-tests provided by ERC and to find a combination of MCQ and CASTest that provides a reliable and valid single effect measure of ALS...... that possessed high reliability, equality of test sets, and ability to discriminate between the two groups of supposedly different ALS competence. CONCLUSIONS: ERC sub-tests of ALS competence possess sufficient reliability and validity. A combined ALS score with equal weighting of one MCQ and one CASTest can...... competence. METHODS: Two groups of participants were included in this randomised, controlled experimental study: a group of newly graduated doctors, who had not taken the ALS course (N=17) and a group of students, who had passed the ALS course 9 months before the study (N=16). Reliability in terms of inter...

  4. Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

    Science.gov (United States)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.

    2010-01-01

    Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

  5. Reliability modeling of degradation of products with multiple performance characteristics based on gamma processes

    International Nuclear Information System (INIS)

    Pan Zhengqiang; Balakrishnan, Narayanaswamy

    2011-01-01

    Many highly reliable products usually have complex structure, with their reliability being evaluated by two or more performance characteristics. In certain physical situations, the degradation of these performance characteristics would be always positive and strictly increasing. In such a case, the gamma process is usually considered as a degradation process due to its independent and non-negative increments properties. In this paper, we suppose that a product has two dependent performance characteristics and that their degradation can be modeled by gamma processes. For such a bivariate degradation involving two performance characteristics, we propose to use a bivariate Birnbaum-Saunders distribution and its marginal distributions to approximate the reliability function. Inferential method for the corresponding model parameters is then developed. Finally, for an illustration of the proposed model and method, a numerical example about fatigue cracks is discussed and some computational results are presented.

  6. Quantification of Wave Model Uncertainties Used for Probabilistic Reliability Assessments of Wave Energy Converters

    DEFF Research Database (Denmark)

    Ambühl, Simon; Kofoed, Jens Peter; Sørensen, John Dalsgaard

    2015-01-01

    Wave models used for site assessments are subjected to model uncertainties, which need to be quantified when using wave model results for probabilistic reliability assessments. This paper focuses on determination of wave model uncertainties. Four different wave models are considered, and validation...... data are collected from published scientific research. The bias and the root-mean-square error, as well as the scatter index, are considered for the significant wave height as well as the mean zero-crossing wave period. Based on an illustrative generic example, this paper presents how the quantified...... uncertainties can be implemented in probabilistic reliability assessments....

  7. Determination of Wave Model Uncertainties used for Probabilistic Reliability Assessments of Wave Energy Devices

    DEFF Research Database (Denmark)

    Ambühl, Simon; Kofoed, Jens Peter; Sørensen, John Dalsgaard

    2014-01-01

    Wave models used for site assessments are subject to model uncertainties, which need to be quantified when using wave model results for probabilistic reliability assessments. This paper focuses on determination of wave model uncertainties. Considered are four different wave models and validation...... data is collected from published scientific research. The bias, the root-mean-square error as well as the scatter index are considered for the significant wave height as well as the mean zero-crossing wave period. Based on an illustrative generic example it is shown how the estimated uncertainties can...... be implemented in probabilistic reliability assessments....

  8. Cognitive human reliability analysis for an assessment of the safety significance of complex transients

    International Nuclear Information System (INIS)

    Amico, P.J.; Hsu, C.J.; Youngblood, R.W.; Fitzpatrick, R.G.

    1989-01-01

    This paper reports that as part of a probabilistic assessment of the safety significance of complex transients at certain PWR power plants, it was necessary to perform a cognitive human reliability analysis. To increase the confidence in the results, it was desirable to make use of actual observations of operator response which were available for the assessment. An approach was developed which incorporated these observations into the human cognitive reliability (HCR) modeling approach. The results obtained provided additional insights over what would have been found using other approaches. These insights were supported by the observations, and it is suggested that this approach be considered for use in future probabilistic safety assessments

  9. Orthopaedic nurses' knowledge and interrater reliability of neurovascular assessments with 2-point discrimination test.

    Science.gov (United States)

    Turney, Jennifer; Raley Noble, Deana; Kim, Son Chae

    2013-01-01

    : This study was conducted to evaluate the effects of education on knowledge and interrater reliability of neurovascular assessments with 2-point discrimination (2-PD) test among pediatric orthopaedic nurses. : A pre- and posttest study was done among 60 nurses attending 2-hour educational sessions. Neurovascular assessments with 2-PD test were performed on 64 casted pediatric patients by the nurses and 5 nurse experts before and after the educational sessions. : The mean neurovascular assessment knowledge score was improved at posteducation compared with the preeducation (p < .001). The 2-PD test interrater reliability also improved from Cohen's kappa value of 0.24-0.48 at posteducation. : The 2-hour educational session may be effective in improving nurses' knowledge and the interrater reliability of neurovascular assessment with 2-PD test.

  10. Reliability Assessment Method of Reactor Protection System Software by Using V and Vbased Bayesian Nets

    International Nuclear Information System (INIS)

    Eom, H. S.; Park, G. Y.; Kang, H. G.; Son, H. S.

    2010-07-01

    Developed a methodology which can be practically used in quantitative reliability assessment of a safety c ritical software for a protection system of nuclear power plants. The base of the proposed methodology is V and V being used in the nuclear industry, which means that it is not affected with specific software development environments or parameters that are necessary for the reliability calculation. Modular and formal sub-BNs in the proposed methodology is useful tool to constitute the whole BN model for reliability assessment of a target software. The proposed V and V based BN model estimates the defects in the software according to the performance of V and V results and then calculate reliability of the software. A case study was carried out to validate the proposed methodology. The target software is the RPS SW which was developed by KNICS project

  11. Investigating the Validity and Reliability of the Vanderbilt Assessment of Leadership in Education

    Science.gov (United States)

    Porter, Andrew C.; Polikoff, Morgan S.; Goldring, Ellen B.; Murphy, Joseph; Elliott, Stephen N.; May, Henry

    2010-01-01

    The Vanderbilt Assessment of Leadership in Education (VAL-ED) is a multirater assessment of principals' learning-centered leadership. The instrument was developed based on the Standards for Educational and Psychological Testing. In this article, we report on the validity and reliability evidence for the VAL-ED accumulated in a national field…

  12. Nurses assessing pain with the Nociception Coma Scale: interrater reliability and validity

    NARCIS (Netherlands)

    Vink, Peter; Eskes, Anne Maria; Lindeboom, Robert; van den Munckhof, Pepijn; Vermeulen, Hester

    2014-01-01

    The Nociception Coma Scale (NCS) is a pain observation tool, developed for patients with disorders of consciousness (DOC) due to acquired brain injury (ABI). The aim of this study was to assess the interrater reliability of the NCS and NCS-R among nurses for the assessment of pain in ABI patients

  13. Assessment of disabilities in stroke patients with apraxia : Internal consistency and inter-observer reliability

    NARCIS (Netherlands)

    van Heugten, CM; Dekker, J; Deelman, BG; Stehmann-Saris, JC; Kinebanian, A

    1999-01-01

    In this paper the internal consistency and inter-observer reliability of the assessment of disabilities in stroke patients with apraxia is presented. Disabilities were assessed by means of observation of activities of daily living (ADL). The study was conducted at occupational therapy departments in

  14. Assessment of disabilities in stroke patients with apraxia: internal consistency and inter-observer reliability.

    NARCIS (Netherlands)

    Heugten, C.M. van; Dekker, J.; Deelman, B.G.; Stehmann-Saris, J.C.; Kinebanian, A.

    1999-01-01

    In this paper the internal consistency and inter-observer reliability of the assessment of disabilities in stroke patients with apraxia is presented. Disabilities were assessed by means of observation of activities of daily living (ADL). The study was conducted at occupational therapy departments in

  15. Experiences in Germany with reliability data assessment, results and current problems

    International Nuclear Information System (INIS)

    Homke, P.; Kutsch, W.; Lindauer, E.

    1982-01-01

    This paper gives a survey on reliability data assessment in the FRG. The activities, which were carried out for the German Risk Assessment Study are presented together with selected results. A systematic data collection in a nuclear power plant is described and the experiences are discussed, which were gained in this project

  16. Diagnosing paratonia in the demented elderly : reliability and validity of the Paratonia Assessment Instrument (PAI)

    NARCIS (Netherlands)

    Hobbelen, Hans; Koopmans, Raymond T C M; Verhey, Frans R J; Habraken, Kitty M; de Bie, Rob A.

    BACKGROUND: Paratonia is one of the associated movement disorders characteristic of dementia. The aim of this study was to develop an assessment tool (the Paratonia Assessment Instrument, PAI), based on the new consensus definition of paratonia. An additional aim was to investigate the reliability

  17. Diagnosing paratonia in the demented elderly: reliability and validity of the Paratonia Assessment Instrument (PAI).

    NARCIS (Netherlands)

    Hobbelen, J.S.; Koopmans, R.T.C.M.; Verhey, F.R.J.; Habraken, K.M.; Bie, R.A. de

    2008-01-01

    BACKGROUND: Paratonia is one of the associated movement disorders characteristic of dementia. The aim of this study was to develop an assessment tool (the Paratonia Assessment Instrument, PAI), based on the new consensus definition of paratonia. An additional aim was to investigate the reliability

  18. A reliable method for ageing of whiting (Merlangius merlangus) for use in stock assessment and management

    DEFF Research Database (Denmark)

    Ross, Stine Dalmann; Hüssy, Karin

    2013-01-01

    Accurate age estimation is important for stock assessment and management. The importance of reliable ageing is emphasized by the impending analytical assessment of whiting (Merlangius merlangus) in the Baltic Sea. Whiting is a top predator in the western Baltic Sea, where it is fished commercially...

  19. Reliability and Validity of the PAQ-C Questionnaire to Assess Physical Activity in Children

    Science.gov (United States)

    Benítez-Porres, Javier; López-Fernández, Iván; Raya, Juan Francisco; Álvarez Carnero, Sabrina; Alvero-Cruz, José Ramón; Álvarez Carnero, Elvis

    2016-01-01

    Background: Physical activity (PA) assessment by questionnaire is a cornerstone in the field of sport epidemiology studies. The Physical Activity Questionnaire for Children (PAQ-C) has been used widely to assess PA in healthy school populations. The aim of this study was to evaluate the reliability and validity of the PAQ-C questionnaire in…

  20. Standardized Patients Provide a Reliable Assessment of Athletic Training Students' Clinical Skills

    Science.gov (United States)

    Armstrong, Kirk J.; Jarriel, Amanda J.

    2016-01-01

    Context: Providing students reliable objective feedback regarding their clinical performance is of great value for ongoing clinical skill assessment. Since a standardized patient (SP) is trained to consistently portray the case, students can be assessed and receive immediate feedback within the same clinical encounter; however, no research, to our…

  1. A Turkish version of myocardial infarction dimensional assessment scale (TR-MIDAS): reliability-validity assesment.

    Science.gov (United States)

    Uysal, Hilal; Ozcan, Şeyda

    2011-06-01

    Many new measuring devices have been developed so that broader psychometric measurements in the coronary artery disease, disease-specific health status measurements, and identification of the broader quality of life can be performed in the recent years. The study was intended to determine whether, and to what extent, MIDAS is a valid and reliable measurement to the patients suffering from myocardial infarction for the first time in Turkey. The research was conducted with the patients hospitalized and treated with myocardial infarction in the cardiology departments of 2 hospitals in Istanbul, Turkey, between 2007 and 2008. Psychometric evaluations of TR-MIDAS were used for validity studies; language validity, content validity, construct validity were examined. For reliability studies; the tool's internal consistency reliability, Cronbach's alpha reliability coefficient, and test-retest reliability were completed. The instrument's content validity index was determined to be "0.95". Principal component analysis revealed six factors with an eigenvalue >1.5. Cronbach's alpha was found to be 0.89 for total scale which was an acceptable value. The total's test-retest reliability was 0.51 (p<0.01). Data obtained at the end of the study supports that Turkish Myocardial Infarction Dimensional Assessment Scale is a valid and reliable instrument as a disease-specific scale to assess the patients' quality of life suffering from myocardial infarction in Turkey. Copyright © 2010 European Society of Cardiology. Published by Elsevier B.V. All rights reserved.

  2. Damage Model for Reliability Assessment of Solder Joints in Wind Turbines

    DEFF Research Database (Denmark)

    Kostandyan, Erik; Sørensen, John Dalsgaard

    2012-01-01

    environmental factors. Reliability assessment for such type of products conventionally is performed by classical reliability techniques based on test data. Usually conventional reliability approaches are time and resource consuming activities. Thus in this paper we choose a physics of failure approach to define...... damage model by Miner’s rule. Our attention is focused on crack propagation in solder joints of electrical components due to the temperature loadings. Based on the proposed method it is described how to find the damage level for a given temperature loading profile. The proposed method is discussed...

  3. An attempt to use FMEA method for an approximate reliability assessment of machinery

    Directory of Open Access Journals (Sweden)

    Przystupa Krzysztof

    2017-01-01

    Full Text Available The paper presents a modified FMEA (Failure Mode and Effect Analysis method to assess reliability of the components that make up a wrench type 2145: MAX Impactol TM Driver Ingersoll Rand Company. This case concerns the analysis of reliability in conditions, when full service data is not known. The aim of the study is to determine the weakest element in the design of the tool.

  4. Further Development of the Assessment of Military Multitasking Performance: Iterative Reliability Testing.

    Directory of Open Access Journals (Sweden)

    Margaret M Weightman

    Full Text Available The Assessment of Military Multitasking Performance (AMMP is a battery of functional dual-tasks and multitasks based on military activities that target known sensorimotor, cognitive, and exertional vulnerabilities after concussion/mild traumatic brain injury (mTBI. The AMMP was developed to help address known limitations in post concussive return to duty assessment and decision making. Once validated, the AMMP is intended for use in combination with other metrics to inform duty-readiness decisions in Active Duty Service Members following concussion. This study used an iterative process of repeated interrater reliability testing and feasibility feedback to drive modifications to the 9 tasks of the original AMMP which resulted in a final version of 6 tasks with metrics that demonstrated clinically acceptable ICCs of > 0.92 (range of 0.92-1.0 for the 3 dual tasks and > 0.87 (range 0.87-1.0 for the metrics of the 3 multitasks. Three metrics involved in recording subject errors across 2 tasks did not achieve ICCs above 0.85 set apriori for multitasks (0.64 and above 0.90 set for dual-tasks (0.77 and 0.86 and were not used for further analysis. This iterative process involved 3 phases of testing with between 13 and 26 subjects, ages 18-42 years, tested in each phase from a combined cohort of healthy controls and Service Members with mTBI. Study findings support continued validation of this assessment tool to provide rehabilitation clinicians further return to duty assessment methods robust to ceiling effects with strong face validity to injured Warriors and their leaders.

  5. Validity, reliability and support for implementation of independence-scaled procedural assessment in laparoscopic surgery.

    Science.gov (United States)

    Kramp, Kelvin H; van Det, Marc J; Veeger, Nic J G M; Pierie, Jean-Pierre E N

    2016-06-01

    There is no widely used method to evaluate procedure-specific laparoscopic skills. The first aim of this study was to develop a procedure-based assessment method. The second aim was to compare its validity, reliability and feasibility with currently available global rating scales (GRSs). An independence-scaled procedural assessment was created by linking the procedural key steps of the laparoscopic cholecystectomy to an independence scale. Subtitled and blinded videos of a novice, an intermediate and an almost competent trainee, were evaluated with GRSs (OSATS and GOALS) and the independence-scaled procedural assessment by seven surgeons, three senior trainees and six scrub nurses. Participants received a short introduction to the GRSs and independence-scaled procedural assessment before assessment. The validity was estimated with the Friedman and Wilcoxon test and the reliability with the intra-class correlation coefficient (ICC). A questionnaire was used to evaluate user opinion. Independence-scaled procedural assessment and GRS scores improved significantly with surgical experience (OSATS p = 0.001, GOALS p < 0.001, independence-scaled procedural assessment p < 0.001). The ICCs of the OSATS, GOALS and independence-scaled procedural assessment were 0.78, 0.74 and 0.84, respectively, among surgeons. The ICCs increased when the ratings of scrub nurses were added to those of the surgeons. The independence-scaled procedural assessment was not considered more of an administrative burden than the GRSs (p = 0.692). A procedural assessment created by combining procedural key steps to an independence scale is a valid, reliable and acceptable assessment instrument in surgery. In contrast to the GRSs, the reliability of the independence-scaled procedural assessment exceeded the threshold of 0.8, indicating that it can also be used for summative assessment. It furthermore seems that scrub nurses can assess the operative competence of surgical trainees.

  6. Assessing Changes in the Reliability of the U.S. Electric Power System

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Peter H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stanford Univ., CA (United States). Dept. of Physics; LaCommare, Kristina H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Eto, Joseph H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sweeney, James L. [Stanford Univ., CA (United States)

    2015-08-01

    Over the past 15 years, the most well-publicized efforts to assess trends in U.S. electric power system reliability have focused only on a subset of all power interruption events (see, for example, Amin 2008 and Campbell 2012)—namely, only the very largest events, which trigger immediate emergency reporting to federal agencies and industry regulators. Anecdotally, these events are thought by many to represent no more than 10% of the power interruptions experienced annually by electricity consumers. Moreover, a review of these emergency reports has identified shortcomings in relying on these data as reliable sources for assessing trends, even with the reliability events they report (Fisher et al. 2012). Recent work has begun to address these limitations by examining trends in reliability data collected annually by electricity distribution companies (Eto et al. 2012). In principle, all power interruptions experienced by electricity customers, regardless of size, are recorded by the distribution utility. Moreover, distribution utilities have a long history of recording this information, often in response to mandates from state public utility commissions (Eto et al. 2006). Thus, studies that rely on reliability data collected by distribution utilities can, in principle, provide a more complete basis upon which to assess trends or changes in reliability over time.

  7. RELIABILITY AND VALIDITY OF SUBJECTIVE ASSESSMENT OF LUMBAR LORDOSIS IN CONVENTIONAL RADIOGRAPHY.

    Science.gov (United States)

    Ruhinda, E; Byanyima, R K; Mugerwa, H

    2014-10-01

    Reliability and validity studies of different lumbar curvature analysis and measurement techniques have been documented however there is limited literature on the reliability and validity of subjective visual analysis. Radiological assessment of lumbar lordotic curve aids in early diagnosis of conditions even before neurologic changes set in. To ascertain the level of reliability and validity of subjective assessment of lumbar lordosis in conventional radiography. A blinded, repeated-measures diagnostic test was carried out on lumbar spine x-ray radiographs. Radiology Department at Joint Clinical Research Centre (JCRC), Mengo-Kampala-Uganda. Seventy (70) lateral lumbar x-ray films were used for this study and were obtained from the archive of JCRC radiology department at Butikiro house, Mengo-Kampala. Poor observer agreement, both inter- and intra-observer, with kappa values of 0.16 was found. Inter-observer agreement was poorer than intra-observer agreement. Kappa values significantly rose when the lumbar lordosis was clustered into four categories without grading each abnormality. The results confirm that subjective assessment of lumbar lordosis has low reliability and validity. Film quality has limited influence on the observer reliability. This study further shows that fewer scale categories of lordosis abnormalities produce better observer reliability.

  8. Balance Assessment in Sports-Related Concussion: Evaluating Test-Retest Reliability of the Equilibrate System.

    Science.gov (United States)

    Odom, Mitchell J; Lee, Young M; Zuckerman, Scott L; Apple, Rachel P; Germanos, Theodore; Solomon, Gary S; Sills, Allen K

    2016-01-01

    This study evaluated the test-retest reliability of a novel computer-based, portable balance assessment tool, the Equilibrate System (ES), used to diagnose sports-related concussion. Twenty-seven students participated in ES testing consisting of three sessions over 4 weeks. The modified Balance Error Scoring System was performed. For each participant, test-retest reliability was established using the intraclass correlation coefficient (ICC). The ES test-retest reliability from baseline to week 2 produced an ICC value of 0.495 (95% CI, 0.123-0.745). Week 2 testing produced ICC values of 0.602 (95% CI, 0.279-0.803) and 0.610 (95% CI, 0.299-0.804), respectively. All other single measures test-retest reliability values produced poor ICC values. Same-day ES testing showed fair to good test-retest reliability while interweek measures displayed poor to fair test-retest reliability. Testing conditions should be controlled when using computerized balance assessment methods. ES testing should only be used as a part of a comprehensive assessment.

  9. Reliability assessment of ultra-thin HfO2 films deposited on silicon wafer

    International Nuclear Information System (INIS)

    Fu, Wei-En; Chang, Chia-Wei; Chang, Yong-Qing; Yao, Chih-Kai; Liao, Jiunn-Der

    2012-01-01

    Highlights: ► Nano-mechanical properties on annealed ultra-thin HfO 2 film are studied. ► By AFM analysis, hardness of the crystallized HfO 2 film significantly increases. ► By nano-indention, the film hardness increases with less contact stiffness. ► Quality assessment on the annealed ultra-thin films can thus be achieved. - Abstract: Ultra-thin hafnium dioxide (HfO 2 ) is used to replace silicon dioxide to meet the required transistor feature size in advanced semiconductor industry. The process integration compatibility and long-term reliability for the transistors depend on the mechanical performance of ultra-thin HfO 2 films. The criteria of reliability including wear resistance, thermal fatigue, and stress-driven failure rely on film adhesion significantly. The adhesion and variations in mechanical properties induced by thermal annealing of the ultra-thin HfO 2 films deposited on silicon wafers (HfO 2 /SiO 2 /Si) are not fully understood. In this work, the mechanical properties of an atomic layer deposited HfO 2 (nominal thickness ≈10 nm) on a silicon wafer were characterized by the diamond-coated tip of an atomic force microscope and compared with those of annealed samples. The results indicate that the annealing process leads to the formation of crystallized HfO 2 phases for the atomic layer deposited HfO 2 . The HfSi x O y complex formed at the interface between HfO 2 and SiO 2 /Si, where the thermal diffusion of Hf, Si, and O atoms occurred. The annealing process increases the surface hardness of crystallized HfO 2 film and therefore the resistance to nano-scratches. In addition, the annealing process significantly decreases the harmonic contact stiffness (or thereafter eliminate the stress at the interface) and increases the nano-hardness, as measured by vertically sensitive nano-indentation. Quality assessments on as-deposited and annealed HfO 2 films can be thereafter used to estimate the mechanical properties and adhesion of ultra-thin HfO 2

  10. Reliability assessment of ultra-thin HfO{sub 2} films deposited on silicon wafer

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Wei-En [Center for Measurement Standards, Industrial Technology Research Institute, Room 216, Building 8, 321 Kuang Fu Road Sec. 2, Hsinchu, Taiwan (China); Chang, Chia-Wei [Department of Materials Science and Engineering, National Cheng Kung University, 1 University Road, Tainan 70101, Taiwan (China); Chang, Yong-Qing [Center for Measurement Standards, Industrial Technology Research Institute, Room 216, Building 8, 321 Kuang Fu Road Sec. 2, Hsinchu, Taiwan (China); Yao, Chih-Kai [Department of Materials Science and Engineering, National Cheng Kung University, 1 University Road, Tainan 70101, Taiwan (China); Liao, Jiunn-Der, E-mail: jdliao@mail.ncku.edu.tw [Department of Materials Science and Engineering, National Cheng Kung University, 1 University Road, Tainan 70101, Taiwan (China)

    2012-09-01

    Highlights: Black-Right-Pointing-Pointer Nano-mechanical properties on annealed ultra-thin HfO{sub 2} film are studied. Black-Right-Pointing-Pointer By AFM analysis, hardness of the crystallized HfO{sub 2} film significantly increases. Black-Right-Pointing-Pointer By nano-indention, the film hardness increases with less contact stiffness. Black-Right-Pointing-Pointer Quality assessment on the annealed ultra-thin films can thus be achieved. - Abstract: Ultra-thin hafnium dioxide (HfO{sub 2}) is used to replace silicon dioxide to meet the required transistor feature size in advanced semiconductor industry. The process integration compatibility and long-term reliability for the transistors depend on the mechanical performance of ultra-thin HfO{sub 2} films. The criteria of reliability including wear resistance, thermal fatigue, and stress-driven failure rely on film adhesion significantly. The adhesion and variations in mechanical properties induced by thermal annealing of the ultra-thin HfO{sub 2} films deposited on silicon wafers (HfO{sub 2}/SiO{sub 2}/Si) are not fully understood. In this work, the mechanical properties of an atomic layer deposited HfO{sub 2} (nominal thickness Almost-Equal-To 10 nm) on a silicon wafer were characterized by the diamond-coated tip of an atomic force microscope and compared with those of annealed samples. The results indicate that the annealing process leads to the formation of crystallized HfO{sub 2} phases for the atomic layer deposited HfO{sub 2}. The HfSi{sub x}O{sub y} complex formed at the interface between HfO{sub 2} and SiO{sub 2}/Si, where the thermal diffusion of Hf, Si, and O atoms occurred. The annealing process increases the surface hardness of crystallized HfO{sub 2} film and therefore the resistance to nano-scratches. In addition, the annealing process significantly decreases the harmonic contact stiffness (or thereafter eliminate the stress at the interface) and increases the nano-hardness, as measured by vertically

  11. An Evidential Reasoning-Based CREAM to Human Reliability Analysis in Maritime Accident Process.

    Science.gov (United States)

    Wu, Bing; Yan, Xinping; Wang, Yang; Soares, C Guedes

    2017-10-01

    This article proposes a modified cognitive reliability and error analysis method (CREAM) for estimating the human error probability in the maritime accident process on the basis of an evidential reasoning approach. This modified CREAM is developed to precisely quantify the linguistic variables of the common performance conditions and to overcome the problem of ignoring the uncertainty caused by incomplete information in the existing CREAM models. Moreover, this article views maritime accident development from the sequential perspective, where a scenario- and barrier-based framework is proposed to describe the maritime accident process. This evidential reasoning-based CREAM approach together with the proposed accident development framework are applied to human reliability analysis of a ship capsizing accident. It will facilitate subjective human reliability analysis in different engineering systems where uncertainty exists in practice. © 2017 Society for Risk Analysis.

  12. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    Science.gov (United States)

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which

  13. Reliability Assessment of Cloud Computing Platform Based on Semiquantitative Information and Evidential Reasoning

    Directory of Open Access Journals (Sweden)

    Hang Wei

    2016-01-01

    Full Text Available A reliability assessment method based on evidential reasoning (ER rule and semiquantitative information is proposed in this paper, where a new reliability assessment architecture including four aspects with both quantitative data and qualitative knowledge is established. The assessment architecture is more objective in describing complex dynamic cloud computing environment than that in traditional method. In addition, the ER rule which has good performance for multiple attribute decision making problem is employed to integrate different types of the attributes in assessment architecture, which can obtain more accurate assessment results. The assessment results of the case study in an actual cloud computing platform verify the effectiveness and the advantage of the proposed method.

  14. Feasibility, reliability, and validity of a smartphone based application for the assessment of cognitive function in the elderly.

    Science.gov (United States)

    Brouillette, Robert M; Foil, Heather; Fontenot, Stephanie; Correro, Anthony; Allen, Ray; Martin, Corby K; Bruce-Keller, Annadora J; Keller, Jeffrey N

    2013-01-01

    While considerable knowledge has been gained through the use of established cognitive and motor assessment tools, there is a considerable interest and need for the development of a battery of reliable and validated assessment tools that provide real-time and remote analysis of cognitive and motor function in the elderly. Smartphones appear to be an obvious choice for the development of these "next-generation" assessment tools for geriatric research, although to date no studies have reported on the use of smartphone-based applications for the study of cognition in the elderly. The primary focus of the current study was to assess the feasibility, reliability, and validity of a smartphone-based application for the assessment of cognitive function in the elderly. A total of 57 non-demented elderly individuals were administered a newly developed smartphone application-based Color-Shape Test (CST) in order to determine its utility in measuring cognitive processing speed in the elderly. Validity of this novel cognitive task was assessed by correlating performance on the CST with scores on widely accepted assessments of cognitive function. Scores on the CST were significantly correlated with global cognition (Mini-Mental State Exam: r = 0.515, psmartphone-based application for the purpose of assessing cognitive function in the elderly. The importance of these findings for the establishment of smartphone-based assessment batteries of cognitive and motor function in the elderly is discussed.

  15. Validity and reliability of self-assessed physical fitness using visual analogue scales

    DEFF Research Database (Denmark)

    Strøyer, Jesper; Essendrop, Morten; Jensen, Lone Donbaek

    2007-01-01

    To test the validity and reliability of self-assessed physical fitness samples included healthcare assistants working at a hospital (women=170, men=17), persons working with physically and mentally handicapped patients (women=530, men= 123), and two separate groups of healthcare students (a) women...... except for flexibility among men. The reliability was moderate to good (ICC = .62 - .80). Self-assessed aerobic fitness, muscle strength, and flexibility showed moderate construct validity and moderate to good reliability using visual analogues.......=91 and men=5 and (b) women=159 and men=10. Five components of physical fitness were self-assessed by Visual Analogue Scales with illustrations and verbal anchors for the extremes: aerobic fitness, muscle strength, endurance, flexibility, and balance. Convergent and divergent validity were evaluated...

  16. Processing the Order of Symbolic Numbers: A Reliable and Unique Predictor of Arithmetic Fluency

    Directory of Open Access Journals (Sweden)

    Stephan E. Vogel

    2017-12-01

    Full Text Available A small but growing body of evidence suggests a link between individual differences in processing the order of numerical symbols (e.g., deciding whether a set of digits is arranged in ascending/descending order or not and arithmetic achievement. However, the reliability of behavioral correlates measuring symbolic and non-symbolic numerical order processing and their relationship to arithmetic abilities remain poorly understood. The present study aims to fill this knowledge gap by examining the behavioral correlates of numerical and non-numerical order processing and their unique associations with arithmetic fluency at two different time points within the same sample of individuals. Thirty-two right-handed adults performed three order judgment tasks consisting of symbolic numbers (i.e., digits, non-symbolic numbers (i.e., dots, and letters of the alphabet. Specifically, participants had to judge as accurately and as quickly as possible whether stimuli were ordered correctly (in ascending/descending order, e.g., 2-3-4; ●●●●-●●●-●●; B-C-D or not (e.g., 4-5-3; ●●●●-●●●●●-●●●; D-E-C. Results of this study demonstrate that numerical order judgments are reliable measurements (i.e., high test-retest reliability, and that the observed relationship between symbolic number processing and arithmetic fluency accounts for a unique and reliable portion of variance over and above the non-symbolic number and the letter conditions. The differential association of symbolic and non-symbolic numbers with arithmetic support the view that processing the order of symbolic and non-symbolic numbers engages different cognitive mechanisms, and that the ability to process ordinal relationships of symbolic numbers is a reliable and unique predictor of arithmetic fluency.

  17. The Development of Marine Accidents Human Reliability Assessment Approach: HEART Methodology and MOP Model

    OpenAIRE

    Ludfi Pratiwi Bowo; Wanginingastuti Mutmainnah; Masao Furusho

    2017-01-01

    Humans are one of the important factors in the assessment of accidents, particularly marine accidents. Hence, studies are conducted to assess the contribution of human factors in accidents. There are two generations of Human Reliability Assessment (HRA) that have been developed. Those methodologies are classified by the differences of viewpoints of problem-solving, as the first generation and second generation. The accident analysis can be determined using three techniques of analysis; sequen...

  18. Managing the uncertainty aspect of reliability in an iterative product development process

    NARCIS (Netherlands)

    Ganesh, N.

    2009-01-01

    This study identifies the design criteria for a method that can be used to manage the risk and uncertainty aspects of product reliability of Really New Innovations (RNI) in an Iterative Product Development Process (IPDP). It is based on 7 years of longitudinal research exploring more than 10

  19. Training less-experienced faculty improves reliability of skills assessment in cardiac surgery.

    Science.gov (United States)

    Lou, Xiaoying; Lee, Richard; Feins, Richard H; Enter, Daniel; Hicks, George L; Verrier, Edward D; Fann, James I

    2014-12-01

    Previous work has demonstrated high inter-rater reliability in the objective assessment of simulated anastomoses among experienced educators. We evaluated the inter-rater reliability of less-experienced educators and the impact of focused training with a video-embedded coronary anastomosis assessment tool. Nine less-experienced cardiothoracic surgery faculty members from different institutions evaluated 2 videos of simulated coronary anastomoses (1 by a medical student and 1 by a resident) at the Thoracic Surgery Directors Association Boot Camp. They then underwent a 30-minute training session using an assessment tool with embedded videos to anchor rating scores for 10 components of coronary artery anastomosis. Afterward, they evaluated 2 videos of a different student and resident performing the task. Components were scored on a 1 to 5 Likert scale, yielding an average composite score. Inter-rater reliabilities of component and composite scores were assessed using intraclass correlation coefficients (ICCs) and overall pass/fail ratings with kappa. All components of the assessment tool exhibited improvement in reliability, with 4 (bite, needle holder use, needle angles, and hand mechanics) improving the most from poor (ICC range, 0.09-0.48) to strong (ICC range, 0.80-0.90) agreement. After training, inter-rater reliabilities for composite scores improved from moderate (ICC, 0.76) to strong (ICC, 0.90) agreement, and for overall pass/fail ratings, from poor (kappa = 0.20) to moderate (kappa = 0.78) agreement. Focused, video-based anchor training facilitates greater inter-rater reliability in the objective assessment of simulated coronary anastomoses. Among raters with less teaching experience, such training may be needed before objective evaluation of technical skills. Published by Elsevier Inc.

  20. Development of a quality-assessment tool for experimental bruxism studies: reliability and validity.

    Science.gov (United States)

    Dawson, Andreas; Raphael, Karen G; Glaros, Alan; Axelsson, Susanna; Arima, Taro; Ernberg, Malin; Farella, Mauro; Lobbezoo, Frank; Manfredini, Daniele; Michelotti, Ambra; Svensson, Peter; List, Thomas

    2013-01-01

    To combine empirical evidence and expert opinion in a formal consensus method in order to develop a quality-assessment tool for experimental bruxism studies in systematic reviews. Tool development comprised five steps: (1) preliminary decisions, (2) item generation, (3) face-validity assessment, (4) reliability and discriminitive validity assessment, and (5) instrument refinement. The kappa value and phi-coefficient were calculated to assess inter-observer reliability and discriminative ability, respectively. Following preliminary decisions and a literature review, a list of 52 items to be considered for inclusion in the tool was compiled. Eleven experts were invited to join a Delphi panel and 10 accepted. Four Delphi rounds reduced the preliminary tool-Quality-Assessment Tool for Experimental Bruxism Studies (Qu-ATEBS)- to 8 items: study aim, study sample, control condition or group, study design, experimental bruxism task, statistics, interpretation of results, and conflict of interest statement. Consensus among the Delphi panelists yielded good face validity. Inter-observer reliability was acceptable (k = 0.77). Discriminative validity was excellent (phi coefficient 1.0; P reviews of experimental bruxism studies, exhibits face validity, excellent discriminative validity, and acceptable inter-observer reliability. Development of quality assessment tools for many other topics in the orofacial pain literature is needed and may follow the described procedure.

  1. Proceeding of 35th domestic symposium on applications of structural reliability and risk assessment methods to nuclear power plants

    International Nuclear Information System (INIS)

    2005-06-01

    As the 35th domestic symposium of Atomic Energy Research Committee, the Japan Welding Engineering Society, the symposium was held titled as Applications of structural reliability/risk assessment methods to nuclear energy'. Six speakers gave lectures titled as 'Structural reliability and risk assessment methods', 'Risk-informed regulation of US nuclear energy and role of probabilistic risk assessment', 'Reliability and risk assessment methods in chemical plants', 'Practical structural design methods based on reliability in architectural and civil areas', 'Maintenance activities based on reliability in thermal power plants' and 'LWR maintenance strategies based on Probabilistic Fracture Mechanics'. (T. Tanaka)

  2. Interrater and Intrarater Reliability of the Tuck Jump Assessment by Health Professionals of Varied Educational Backgrounds

    Directory of Open Access Journals (Sweden)

    Lisa A. Dudley

    2013-01-01

    Full Text Available Objective. The Tuck Jump Assessment (TJA, a clinical plyometric assessment, identifies 10 jumping and landing technique flaws. The study objective was to investigate TJA interrater and intrarater reliability with raters of different educational and clinical backgrounds. Methods. 40 participants were video recorded performing the TJA using published protocol and instructions. Five raters of varied educational and clinical backgrounds scored the TJA. Each score of the 10 technique flaws was summed for the total TJA score. Approximately one month later, 3 raters scored the videos again. Intraclass correlation coefficients determined interrater (5 and 3 raters for first and second session, resp. and intrarater (3 raters reliability. Results. Interrater reliability with 5 raters was poor (ICC = 0.47; 95% confidence intervals (CI 0.33–0.62. Interrater reliability between 3 raters who completed 2 scoring sessions improved from 0.52 (95% CI 0.35–0.68 for session one to 0.69 (95% CI 0.55–0.81 for session two. Intrarater reliability was poor to moderate, ranging from 0.44 (95% CI 0.22–0.68 to 0.72 (95% CI 0.55–0.84. Conclusion. Published protocol and training of raters were insufficient to allow consistent TJA scoring. There may be a learned effect with the TJA since interrater reliability improved with repetition. TJA instructions and training should be modified and enhanced before clinical implementation.

  3. Method for assessing software reliability of the document management system using the RFID technology

    Directory of Open Access Journals (Sweden)

    Kiedrowicz Maciej

    2016-01-01

    Full Text Available The deliberations presented in this study refer to the method for assessing software reliability of the docu-ment management system, using the RFID technology. A method for determining the reliability structure of the dis-cussed software, understood as the index vector for assessing reliability of its components, was proposed. The model of the analyzed software is the control transfer graph, in which the probability of activating individual components during the system's operation results from the so-called operational profile, which characterizes the actual working environment. The reliability structure is established as a result of the solution of a specific mathematical software task. The knowledge of the reliability structure of the software makes it possible to properly plan the time and finan-cial expenses necessary to build the software, which would meet the reliability requirements. The application of the presented method is illustrated by the number example, corresponding to the software reality of the RFID document management system.

  4. A Closed-Form Technique for the Reliability and Risk Assessment of Wind Turbine Systems

    Directory of Open Access Journals (Sweden)

    Leonardo Dueñas-Osorio

    2012-06-01

    Full Text Available This paper proposes a closed-form method to evaluate wind turbine system reliability and associated failure consequences. Monte Carlo simulation, a widely used approach for system reliability assessment, usually requires large numbers of computational experiments, while existing analytical methods are limited to simple system event configurations with a focus on average values of reliability metrics. By analyzing a wind turbine system and its components in a combinatorial yet computationally efficient form, the proposed approach provides an entire probability distribution of system failure that contains all possible configurations of component failure and survival events. The approach is also capable of handling unique component attributes such as downtime and repair cost needed for risk estimations, and enables sensitivity analysis for quantifying the criticality of individual components to wind turbine system reliability. Applications of the technique are illustrated by assessing the reliability of a 12-subassembly turbine system. In addition, component downtimes and repair costs of components are embedded in the formulation to compute expected annual wind turbine unavailability and repair cost probabilities, and component importance metrics useful for maintenance planning and research prioritization. Furthermore, this paper introduces a recursive solution to closed-form method and applies this to a 45-component turbine system. The proposed approach proves to be computationally efficient and yields vital reliability information that could be readily used by wind farm stakeholders for decision making and risk management.

  5. Reliability assessment of distribution system with the integration of renewable distributed generation

    International Nuclear Information System (INIS)

    Adefarati, T.; Bansal, R.C.

    2017-01-01

    Highlights: • Addresses impacts of renewable DG on the reliability of the distribution system. • Multi-objective formulation for maximizing the cost saving with integration of DG. • Uses Markov model to study the stochastic characteristics of the major components. • The investigation is done using modified RBTS bus test distribution system. • Proposed approach is useful for electric utilities to enhance the reliability. - Abstract: Recent studies have shown that renewable energy resources will contribute substantially to future energy generation owing to the rapid depletion of fossil fuels. Wind and solar energy resources are major sources of renewable energy that have the ability to reduce the energy crisis and the greenhouse gases emitted by the conventional power plants. Reliability assessment is one of the key indicators to measure the impact of the renewable distributed generation (DG) units in the distribution networks and to minimize the cost that is associated with power outage. This paper presents a comprehensive reliability assessment of the distribution system that satisfies the consumer load requirements with the penetration of wind turbine generator (WTG), electric storage system (ESS) and photovoltaic (PV). A Markov model is proposed to access the stochastic characteristics of the major components of the renewable DG resources as well as their influence on the reliability of a conventional distribution system. The results obtained from the case studies have demonstrated the effectiveness of using WTG, ESS and PV to enhance the reliability of the conventional distribution system.

  6. Assessment of Equipment Capability to Perform Reliably under Severe Accident Conditions

    International Nuclear Information System (INIS)

    2017-07-01

    The experience from the last 40 years has shown that severe accidents can subject electrical and instrumentation and control (I&C) equipment to environmental conditions exceeding the equipment’s original design basis assumptions. Severe accident conditions can then cause rapid degradation or damage to various degrees up to complete failure of such equipment. This publication provides the technical basis to consider when assessing the capability of electrical and I&C equipment to perform reliably during a severe accident. It provides examples of calculation tools to determine the environmental parameters as well as examples and methods that Member States can apply to assess equipment reliability.

  7. Phd study of reliability and validity: One step closer to a standardized music therapy assessment model

    DEFF Research Database (Denmark)

    Jacobsen, Stine Lindahl

    The paper will present a phd study concerning reliability and validity of music therapy assessment model “Assessment of Parenting Competences” (APC) in the area of families with emotionally neglected children. This study had a multiple strategy design with a philosophical base of critical realism...... and pragmatism. The fixed design for this study was a between and within groups design in testing the APCs reliability and validity. The two different groups were parents with neglected children and parents with non-neglected children. The flexible design had a multiple case study strategy specifically...

  8. Reliability and Validity of 3 Methods of Assessing Orthopedic Resident Skill in Shoulder Surgery.

    Science.gov (United States)

    Bernard, Johnathan A; Dattilo, Jonathan R; Srikumaran, Uma; Zikria, Bashir A; Jain, Amit; LaPorte, Dawn M

    Traditional measures for evaluating resident surgical technical skills (e.g., case logs) assess operative volume but not level of surgical proficiency. Our goal was to compare the reliability and validity of 3 tools for measuring surgical skill among orthopedic residents when performing 3 open surgical approaches to the shoulder. A total of 23 residents at different stages of their surgical training were tested for technical skill pertaining to 3 shoulder surgical approaches using the following measures: Objective Structured Assessment of Technical Skills (OSATS) checklists, the Global Rating Scale (GRS), and a final pass/fail assessment determined by 3 upper extremity surgeons. Adverse events were recorded. The Cronbach α coefficient was used to assess reliability of the OSATS checklists and GRS scores. Interrater reliability was calculated with intraclass correlation coefficients. Correlations among OSATS checklist scores, GRS scores, and pass/fail assessment were calculated with Spearman ρ. Validity of OSATS checklists was determined using analysis of variance with postgraduate year (PGY) as a between-subjects factor. Significance was set at p shoulder approaches. Checklist scores showed superior interrater reliability compared with GRS and subjective pass/fail measurements. GRS scores were positively correlated across training years. The incidence of adverse events was significantly higher among PGY-1 and PGY-2 residents compared with more experienced residents. OSATS checklists are a valid and reliable assessment of technical skills across 3 surgical shoulder approaches. However, checklist scores do not measure quality of technique. Documenting adverse events is necessary to assess quality of technique and ultimate pass/fail status. Multiple methods of assessing surgical skill should be considered when evaluating orthopedic resident surgical performance. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights

  9. Development of equipment reliability process using predictive technologies at Hamaoka Nuclear Power Station

    International Nuclear Information System (INIS)

    Taniguchi, Yuji; Sakuragi, Futoshi; Hamada, Seiichi

    2014-01-01

    Development of equipment reliability(ER) process, specifically for predictive maintenance (PdM) technologies integrated condition based maintenance (CBM) process, at Hamaoka Nuclear Power Station is introduced in this paper. Integration of predictive maintenance technologies such as vibration, oil analysis and thermo monitoring is more than important to establish strong maintenance strategies and to direct a specific technical development. In addition, a practical example of CBM is also presented to support the advantage of the idea. (author)

  10. Isometric abdominal wall muscle strength assessment in individuals with incisional hernia: a prospective reliability study

    DEFF Research Database (Denmark)

    Jensen, K. K.; Kjær, Michael; Jorgensen, L. N.

    2016-01-01

    Purpose To determine the reliability of measurements obtained by the Good Strength dynamometer, determining isometric abdominal wall and back muscle strength in patients with ventral incisional hernia (VIH) and healthy volunteers with an intact abdominal wall. Methods Ten patients with VIH and ten...... and extension showed excellent test–retest reliability for both patients with VIH (ICC 0.91 and 0.99) and healthy controls (ICC 0.97 and 0.96). Bland and Altman plots showed that no systematic bias was present for neither truncal flexion nor extension when assessing reliability. For patients with VIH...... and IPAQ was found. Conclusions The Good Strength dynamometer provided a reliable, low-cost measure of truncal flexion and extension in patients with VIH....

  11. An Impact of Thermodynamic Processes in Human Bodies on Performance Reliability of Individuals

    Directory of Open Access Journals (Sweden)

    Smalko Zbigniew

    2015-01-01

    Full Text Available The article presents the problem of the influence of thermodynamic factors on human fallibility in different zones of thermal discomfort. Describes the processes of energy in the human body. Been given a formal description of the energy balance of the human body thermoregulation. Pointed to human reactions to temperature changes of internal and external environment, including reactions associated with exercise. The methodology to estimate and determine the reliability of indicators of human basal acting in different zones of thermal discomfort. The significant effect of thermodynamic factors on the reliability and security ofperson.

  12. Reliability and Validity Evidence of Multiple Balance Assessments in Athletes With a Concussion

    Science.gov (United States)

    Murray, Nicholas; Salvatore, Anthony; Powell, Douglas; Reed-Jones, Rebecca

    2014-01-01

    Context: An estimated 300 000 sport-related concussion injuries occur in the United States annually. Approximately 30% of individuals with concussions experience balance disturbances. Common methods of balance assessment include the Clinical Test of Sensory Organization and Balance (CTSIB), the Sensory Organization Test (SOT), the Balance Error Scoring System (BESS), and the Romberg test; however, the National Collegiate Athletic Association recommended the Wii Fit as an alternative measure of balance in athletes with a concussion. A central concern regarding the implementation of the Wii Fit is whether it is reliable and valid for measuring balance disturbance in athletes with concussion. Objective: To examine the reliability and validity evidence for the CTSIB, SOT, BESS, Romberg test, and Wii Fit for detecting balance disturbance in athletes with a concussion. Data Sources: Literature considered for review included publications with reliability and validity data for the assessments of balance (CTSIB, SOT, BESS, Romberg test, and Wii Fit) from PubMed, PsycINFO, and CINAHL. Data Extraction: We identified 63 relevant articles for consideration in the review. Of the 63 articles, 28 were considered appropriate for inclusion and 35 were excluded. Data Synthesis: No current reliability or validity information supports the use of the CTSIB, SOT, Romberg test, or Wii Fit for balance assessment in athletes with a concussion. The BESS demonstrated moderate to high reliability (interclass correlation coefficient = 0.87) and low to moderate validity (sensitivity = 34%, specificity = 87%). However, the Romberg test and Wii Fit have been shown to be reliable tools in the assessment of balance in Parkinson patients. Conclusions: The BESS can evaluate balance problems after a concussion. However, it lacks the ability to detect balance problems after the third day of recovery. Further investigation is needed to establish the use of the CTSIB, SOT, Romberg test, and Wii Fit for

  13. Validity and reliability of a nutrition knowledge survey for assessment in elementary school children.

    Science.gov (United States)

    Gower, Jared R; Moyer-Mileur, Laurie J; Wilkinson, Robert D; Slater, Hillarie; Jordan, Kristine C

    2010-03-01

    Limited surveys are available to assess the nutrition knowledge of children. The goals of this study were to test the validity and reliability of a computer nutrition knowledge survey for elementary school students and to evaluate the impact of the "Fit Kids 'r' Healthy Kids" nutrition intervention via the knowledge survey. During survey development, a sample (n=12) of health educators, elementary school teachers, and registered dietitians assessed the survey. The target population consisted of first- through fourth-grade students from Salt Lake City, UT, metropolitan area schools. Participants were divided into reliability (n=68), intervention (n=74), and control groups (n=59). The reliability group took the survey twice (2 weeks apart); the intervention and control groups also took the survey twice, but at pre- and post-intervention (4 weeks later). Only students from the intervention group participated in four weekly nutrition classes. Reliability was assessed by Pearson's correlation coefficients for knowledge scores. Results demonstrated appropriate content validity, as indicated by expert peer ratings. Test-retest reliability correlations were found to be significant for the overall survey (r=0.54; PNutrition knowledge was assessed upon program completion with paired samples t tests. Students from the intervention group demonstrated improvement in nutrition knowledge (12.2+/-1.9 to 13.5+/-1.6; Pnutrition survey demonstrated content validity and test-retest reliability for first- through fourth-grade elementary school children. Also, the study results imply that the Fit Kids 'r' Healthy Kids intervention promoted gains in nutrition knowledge. Overall, the computer survey shows promise as an appealing medium for assessing nutrition knowledge in children. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  14. Reliability and validity evidence of multiple balance assessments in athletes with a concussion.

    Science.gov (United States)

    Murray, Nicholas; Salvatore, Anthony; Powell, Douglas; Reed-Jones, Rebecca

    2014-01-01

    An estimated 300 000 sport-related concussion injuries occur in the United States annually. Approximately 30% of individuals with concussions experience balance disturbances. Common methods of balance assessment include the Clinical Test of Sensory Organization and Balance (CTSIB), the Sensory Organization Test (SOT), the Balance Error Scoring System (BESS), and the Romberg test; however, the National Collegiate Athletic Association recommended the Wii Fit as an alternative measure of balance in athletes with a concussion. A central concern regarding the implementation of the Wii Fit is whether it is reliable and valid for measuring balance disturbance in athletes with concussion. To examine the reliability and validity evidence for the CTSIB, SOT, BESS, Romberg test, and Wii Fit for detecting balance disturbance in athletes with a concussion. Literature considered for review included publications with reliability and validity data for the assessments of balance (CTSIB, SOT, BESS, Romberg test, and Wii Fit) from PubMed, PsycINFO, and CINAHL. We identified 63 relevant articles for consideration in the review. Of the 63 articles, 28 were considered appropriate for inclusion and 35 were excluded. No current reliability or validity information supports the use of the CTSIB, SOT, Romberg test, or Wii Fit for balance assessment in athletes with a concussion. The BESS demonstrated moderate to high reliability (interclass correlation coefficient = 0.87) and low to moderate validity (sensitivity = 34%, specificity = 87%). However, the Romberg test and Wii Fit have been shown to be reliable tools in the assessment of balance in Parkinson patients. The BESS can evaluate balance problems after a concussion. However, it lacks the ability to detect balance problems after the third day of recovery. Further investigation is needed to establish the use of the CTSIB, SOT, Romberg test, and Wii Fit for assessing balance in athletes with concussions.

  15. Reliability of Lactation Assessment Tools Applied to Overweight and Obese Women.

    Science.gov (United States)

    Chapman, Donna J; Doughty, Katherine; Mullin, Elizabeth M; Pérez-Escamilla, Rafael

    2016-05-01

    The interrater reliability of lactation assessment tools has not been evaluated in overweight/obese women. This study aimed to compare the interrater reliability of 4 lactation assessment tools in this population. A convenience sample of 45 women (body mass index > 27.0) was videotaped while breastfeeding (twice daily on days 2, 4, and 7 postpartum). Three International Board Certified Lactation Consultants independently rated each videotaped session using 4 tools (Infant Breastfeeding Assessment Tool [IBFAT], modified LATCH [mLATCH], modified Via Christi [mVC], and Riordan's Tool [RT]). For each day and tool, we evaluated interrater reliability with 1-way repeated-measures analyses of variance, intraclass correlation coefficients (ICCs), and percentage absolute agreement between raters. Analyses of variance showed significant differences between raters' scores on day 2 (all scales) and day 7 (RT). Intraclass correlation coefficient values reflected good (mLATCH) to excellent reliability (IBFAT, mVC, and RT) on days 2 and 7. All day 4 ICCs reflected good reliability. The ICC for mLATCH was significantly lower than all others on day 2 and was significantly lower than IBFAT (day 7). Percentage absolute interrater agreement for scale components ranged from 31% (day 2: observable swallowing, RT) to 92% (day 7: IBFAT, fixing; and mVC, latch time). Swallowing scores on all scales had the lowest levels of interrater agreement (31%-64%). We demonstrated differences in the interrater reliability of 4 lactation assessment tools when applied to overweight/obese women, with the lowest values observed on day 4. Swallowing assessment was particularly unreliable. Researchers and clinicians using these scales should be aware of the differences in their psychometric behavior. © The Author(s) 2015.

  16. Lower limb spasticity assessment using an inertial sensor: a reliability study

    International Nuclear Information System (INIS)

    Sterpi, I; Colombo, R; Caroli, A; Meazza, E; Maggioni, G; Pistarini, C

    2013-01-01

    Spasticity is a common motor impairment in patients with neurological disorders that can prevent functional recovery after rehabilitation. In the clinical setting, its assessment is carried out using standardized clinical scales. The aim of this study was to verify the applicability of inertial sensors for an objective measurement of quadriceps spasticity and evaluate its test–retest and inter-rater reliability during the implementation of the Wartenberg pendulum test. Ten healthy subjects and 11 patients in vegetative state with severe brain damage were enrolled in this study. Subjects were evaluated three times on three consecutive days. The test–retest reliability of measurement was assessed in the first two days. The third day was devoted to inter-rater reliability assessment. In addition, the lower limb muscle tone was bilaterally evaluated at the knee joint by the modified Ashworth scale. The factorial ANOVA analysis showed that the implemented method allowed us to discriminate between healthy and pathological conditions. The fairly low SEM and high ICC values obtained for the pendulum parameters indicated a good test–retest and inter-rater reliability of measurement. This study shows that an inertial sensor can be reliably used to characterize leg kinematics during the Wartenberg pendulum test and provide quantitative evaluation of quadriceps spasticity. (paper)

  17. Reliability of the Alzheimer's disease assessment scale (ADAS-Cog) in longitudinal studies.

    Science.gov (United States)

    Khan, Anzalee; Yavorsky, Christian; DiClemente, Guillermo; Opler, Mark; Liechti, Stacy; Rothman, Brian; Jovic, Sofija

    2013-11-01

    Considering the scarcity of longitudinal assessments of reliability, there is need for a more precise understanding of cognitive decline in Alzheimer's Disease (AD). The primary goal was to assess longitudinal changes in inter-rater reliability, test retest reliability and internal consistency of scores of the ADAS-Cog. 2,618 AD subjects were enrolled in seven randomized, double-blind, placebo-controlled, multicenter-trials from 1986 to 2009. Reliability, internal-consistency and cross-sectional analysis of ADAS-Cog and MMSE across seven visits were examined. Intra-class correlation (ICC) for ADAS-Cog was moderate to high supporting their reliability. Absolute Agreement ICCs 0.392 (Visit-7) to 0.806 (Visit-2) showed a progressive decrease in correlations across time. Item analysis revealed a decrease in item correlations, with the lowest correlations for Visit 7 for Commands (ICC=0.148), Comprehension (ICC=0.092), Spoken Language (ICC=0.044). Suitable assessment of AD treatments is maintained through accurate measurement of clinically significant outcomes. Targeted rater education ADAS-Cog items over-time can improve ability to administer and score the scale.

  18. Evaluation of the Validity and Reliability of the Waterlow Pressure Ulcer Risk Assessment Scale.

    Science.gov (United States)

    Charalambous, Charalambos; Koulori, Agoritsa; Vasilopoulos, Aristidis; Roupa, Zoe

    2018-04-01

    Prevention is the ideal strategy to tackle the problem of pressure ulcers. Pressure ulcer risk assessment scales are one of the most pivotal measures applied to tackle the problem, much criticisms has been developed regarding the validity and reliability of these scales. To investigate the validity and reliability of the Waterlow pressure ulcer risk assessment scale. The methodology used is a narrative literature review, the bibliography was reviewed through Cinahl, Pubmed, EBSCO, Medline and Google scholar, 26 scientific articles where identified. The articles where chosen due to their direct correlation with the objective under study and their scientific relevance. The construct and face validity of the Waterlow appears adequate, but with regards to content validity changes in the category age and gender can be beneficial. The concurrent validity cannot be assessed. The predictive validity of the Waterlow is characterized by high specificity and low sensitivity. The inter-rater reliability has been demonstrated to be inadequate, this may be due to lack of clear definitions within the categories and differentiating level of knowledge between the users. Due to the limitations presented regarding the validity and reliability of the Waterlow pressure ulcer risk assessment scale, the scale should be used in conjunction with clinical assessment to provide optimum results.

  19. Evaluation of the Validity and Reliability of the Waterlow Pressure Ulcer Risk Assessment Scale

    Science.gov (United States)

    Charalambous, Charalambos; Koulori, Agoritsa; Vasilopoulos, Aristidis; Roupa, Zoe

    2018-01-01

    Introduction Prevention is the ideal strategy to tackle the problem of pressure ulcers. Pressure ulcer risk assessment scales are one of the most pivotal measures applied to tackle the problem, much criticisms has been developed regarding the validity and reliability of these scales. Objective To investigate the validity and reliability of the Waterlow pressure ulcer risk assessment scale. Method The methodology used is a narrative literature review, the bibliography was reviewed through Cinahl, Pubmed, EBSCO, Medline and Google scholar, 26 scientific articles where identified. The articles where chosen due to their direct correlation with the objective under study and their scientific relevance. Results The construct and face validity of the Waterlow appears adequate, but with regards to content validity changes in the category age and gender can be beneficial. The concurrent validity cannot be assessed. The predictive validity of the Waterlow is characterized by high specificity and low sensitivity. The inter-rater reliability has been demonstrated to be inadequate, this may be due to lack of clear definitions within the categories and differentiating level of knowledge between the users. Conclusion Due to the limitations presented regarding the validity and reliability of the Waterlow pressure ulcer risk assessment scale, the scale should be used in conjunction with clinical assessment to provide optimum results. PMID:29736104

  20. Wii Balance Board: Reliability and Clinical Use in Assessment of Balance in Healthy Elderly Women.

    Science.gov (United States)

    Monteiro-Junior, Renato Sobral; Ferreira, Arthur Sá; Puell, Vivian Neiva; Lattari, Eduardo; Machado, Sérgio; Otero Vaghetti, César Augusto; da Silva, Elirez Bezerra

    2015-01-01

    Force plate is considered gold standard tool to assess body balance. However the Wii Balance Board (WBB) platform is a trustworthy equipment to assess stabilometric components in young people. Thus, we aim to examine the reliability of measures of center of pressure with WBB in healthy elderly women. Twenty one healthy and physically active women were enrolled in the study (age: 64 ± 7 years; body mass index: 29 ± 5 kg/m2. The WBB was used to assess the center of pressure measures in the individuals. Pressure was linearly applied to different points to test the platform precision. Three assessments were performed, with two of them being held on the same day at a 5- to 10-minute interval, and the third one was performed 48 h later. A linear regression analysis was used to find out linearity, while the intraclass correlation coefficient was used to assess reliability. The platform precision was adequate (R2 = 0.997, P = 0.01). Center of pressure measures showed an excellent reliability (all intraclass correlation coefficient values were > 0.90; p < 0.01). The WBB is a precise and reliable tool of body stability quantitative measure in healthy active elderly women and its use should be encouraged in clinical settings.

  1. Reliability assessment of Passive Containment Cooling System of an Advanced Reactor using APSRA methodology

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Mukesh, E-mail: mukeshd@barc.gov.in [Reactor Engineering Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Chakravarty, Aranyak [School of Nuclear Studies and Application, Jadavpur University, Kolkata 700032 (India); Nayak, A.K. [Reactor Engineering Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Prasad, Hari; Gopika, V. [Reactor Safety Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2014-10-15

    Highlights: • The paper deals with the reliability assessment of Passive Containment Cooling System of Advanced Heavy Water Reactor. • Assessment of Passive System ReliAbility (APSRA) methodology is used for reliability assessment. • Performance assessment of the PCCS is initially performed during a postulated design basis LOCA. • The parameters affecting the system performance are then identified and considered for further analysis. • The failure probabilities of the various components are assessed through a classical PSA treatment using generic data. - Abstract: Passive Systems are increasingly playing a prominent role in the advanced nuclear reactor systems and are being utilised in normal operations as well as safety systems of the reactors following an accident. The Passive Containment Cooling System (PCCS) is one of the several passive safety features in an Advanced Reactor (AHWR). In this paper, the APSRA methodology has been employed for reliability evaluation of the PCCS of AHWR. Performance assessment of the PCCS is initially performed during a postulated design basis LOCA using the best-estimate code RELAP5/Mod 3.2. The parameters affecting the system performance are then identified and considered for further analysis. Based on some pre-determined failure criterion, the failure surface for the system is predicted using the best-estimate code taking into account the deviations of the identified parameters from their nominal states as well as the model uncertainties inherent to the best estimate code. Root diagnosis is then carried out to determine the various failure causes, which occurs mainly due to malfunctioning of mechanical components. The failure probabilities of the various components are assessed through a classical PSA treatment using generic data. The reliability of the PCCS is then evaluated from the probability of availability of these components.

  2. Reliability assessment of Passive Containment Cooling System of an Advanced Reactor using APSRA methodology

    International Nuclear Information System (INIS)

    Kumar, Mukesh; Chakravarty, Aranyak; Nayak, A.K.; Prasad, Hari; Gopika, V.

    2014-01-01

    Highlights: • The paper deals with the reliability assessment of Passive Containment Cooling System of Advanced Heavy Water Reactor. • Assessment of Passive System ReliAbility (APSRA) methodology is used for reliability assessment. • Performance assessment of the PCCS is initially performed during a postulated design basis LOCA. • The parameters affecting the system performance are then identified and considered for further analysis. • The failure probabilities of the various components are assessed through a classical PSA treatment using generic data. - Abstract: Passive Systems are increasingly playing a prominent role in the advanced nuclear reactor systems and are being utilised in normal operations as well as safety systems of the reactors following an accident. The Passive Containment Cooling System (PCCS) is one of the several passive safety features in an Advanced Reactor (AHWR). In this paper, the APSRA methodology has been employed for reliability evaluation of the PCCS of AHWR. Performance assessment of the PCCS is initially performed during a postulated design basis LOCA using the best-estimate code RELAP5/Mod 3.2. The parameters affecting the system performance are then identified and considered for further analysis. Based on some pre-determined failure criterion, the failure surface for the system is predicted using the best-estimate code taking into account the deviations of the identified parameters from their nominal states as well as the model uncertainties inherent to the best estimate code. Root diagnosis is then carried out to determine the various failure causes, which occurs mainly due to malfunctioning of mechanical components. The failure probabilities of the various components are assessed through a classical PSA treatment using generic data. The reliability of the PCCS is then evaluated from the probability of availability of these components

  3. Reliability of magnetic resonance imaging assessment of rotator cuff: the ROW study.

    Science.gov (United States)

    Jain, Nitin B; Collins, Jamie; Newman, Joel S; Katz, Jeffrey N; Losina, Elena; Higgins, Laurence D

    2015-03-01

    Physiatrists encounter patients with rotator cuff disorders, and imaging is frequently an important component of their diagnostic assessment. However, there is a paucity of literature on the reliability of magnetic resonance imaging (MRI) assessment between shoulder specialists and musculoskeletal radiologists. We assessed inter- and intrarater reliability of MRI characteristics of the rotator cuff. Cross-sectional secondary analyses in a prospective cohort study. Academic tertiary care centers. Subjects with shoulder pain were recruited from orthopedic and physiatry clinics. Two shoulder-fellowship-trained physicians (a physiatrist and a shoulder surgeon) jointly performed a blinded composite MRI review by consensus of 31 subjects with shoulder pain. Subsequently, MRI was reviewed by one fellowship-trained musculoskeletal radiologist. We calculated the Cohen kappa coefficients and percentage agreement among the 2 reviews (composite review of 2 shoulder specialists versus that of the musculoskeletal radiologist). Intrarater reliability was assessed among the shoulder specialists by performing a repeated blinded composite MRI review. In addition to this repeated composite review, only one of the physiatry shoulder specialists performed an additional review. Interrater reliability (shoulder specialists versus musculoskeletal radiologist) was substantial for the presence or absence of tear (kappa 0.90 [95% confidence interval {CI}, 0.72-1.00]), tear thickness (kappa 0.84 [95% CI, 0.70-0.99]), longitudinal size of tear (kappa 0.75 [95% CI, 0.44-1.00]), fatty infiltration (kappa 0.62 [95% CI, 0.45-0.79]), and muscle atrophy (kappa 0.68 [95% CI, 0.50-0.86]). There was only fair interrater reliability of the transverse size of tear (kappa 0.20 [95% CI, 0.00-0.51]). The kappa for intrarater reliability was high for tear thickness (0.88 [95% CI, 0.72-1.00]), longitudinal tear size (0.61 [95% CI, 0.22-0.99]), fatty infiltration (0.89 [95% CI, 0.80,-0.98]), and muscle atrophy

  4. An enhanced reliability-oriented workforce planning model for process industry using combined fuzzy goal programming and differential evolution approach

    Science.gov (United States)

    Ighravwe, D. E.; Oke, S. A.; Adebiyi, K. A.

    2018-03-01

    This paper draws on the "human reliability" concept as a structure for gaining insight into the maintenance workforce assessment in a process industry. Human reliability hinges on developing the reliability of humans to a threshold that guides the maintenance workforce to execute accurate decisions within the limits of resources and time allocations. This concept offers a worthwhile point of deviation to encompass three elegant adjustments to literature model in terms of maintenance time, workforce performance and return-on-workforce investments. These fully explain the results of our influence. The presented structure breaks new grounds in maintenance workforce theory and practice from a number of perspectives. First, we have successfully implemented fuzzy goal programming (FGP) and differential evolution (DE) techniques for the solution of optimisation problem in maintenance of a process plant for the first time. The results obtained in this work showed better quality of solution from the DE algorithm compared with those of genetic algorithm and particle swarm optimisation algorithm, thus expressing superiority of the proposed procedure over them. Second, the analytical discourse, which was framed on stochastic theory, focusing on specific application to a process plant in Nigeria is a novelty. The work provides more insights into maintenance workforce planning during overhaul rework and overtime maintenance activities in manufacturing systems and demonstrated capacity in generating substantially helpful information for practice.

  5. Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR): Part 1, Overview of NUCLARR data retrieval: User's guide

    International Nuclear Information System (INIS)

    Gilmore, W.E.; Gentillon, C.D.; Gertman, D.I.; Beers, G.H.; Galyean, W.J.; Gilbert, B.G.

    1988-06-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automated data base management system for processing and storing human error probability and hardware component failure data. The NUCLARR system software resides on an IBM (or compatible) personal micro-computer. NUCLARR can be used by the end user to furnish data inputs for both human and hardware reliability analysis in support of a variety of risk assessment activities. The NUCLARR system is documented in a five-volume series of reports. Volume IV of this series is the User's Guide for operating the NUCLARR software and is presented in three parts. This document, Part 1: Overview of NUCLARR Data Retrieval provides an introductory overview to the system's capabilities and procedures for data retrieval. The methods and criteria for selection of data sources and entering them into the NUCLARR system are also described in this document

  6. The Outcome and Assessment Information Set (OASIS): A Review of Validity and Reliability

    Science.gov (United States)

    O’CONNOR, MELISSA; DAVITT, JOAN K.

    2015-01-01

    The Outcome and Assessment Information Set (OASIS) is the patient-specific, standardized assessment used in Medicare home health care to plan care, determine reimbursement, and measure quality. Since its inception in 1999, there has been debate over the reliability and validity of the OASIS as a research tool and outcome measure. A systematic literature review of English-language articles identified 12 studies published in the last 10 years examining the validity and reliability of the OASIS. Empirical findings indicate the validity and reliability of the OASIS range from low to moderate but vary depending on the item studied. Limitations in the existing research include: nonrepresentative samples; inconsistencies in methods used, items tested, measurement, and statistical procedures; and the changes to the OASIS itself over time. The inconsistencies suggest that these results are tentative at best; additional research is needed to confirm the value of the OASIS for measuring patient outcomes, research, and quality improvement. PMID:23216513

  7. Statistical reliability assessment of UT round-robin test data for piping welds

    International Nuclear Information System (INIS)

    Kim, H.M.; Park, I.K.; Park, U.S.; Park, Y.W.; Kang, S.C.; Lee, J.H.

    2004-01-01

    Ultrasonic NDE is one of important technologies in the life-time maintenance of nuclear power plant. Ultrasonic inspection system is consisted of the operator, equipment and procedure. The reliability of ultrasonic inspection system is affected by its ability. The performance demonstration round robin was conducted to quantify the capability of ultrasonic inspection for in-service. Several teams employed procedures that met or exceeded with ASME sec. XI code requirements detected the piping of nuclear power plant with various cracks to evaluate the capability of detection and sizing. In this paper, the statistical reliability assessment of ultrasonic nondestructive inspection data using probability of detection (POD) is presented. The result of POD using logistic model was useful to the reliability assessment for the NDE hit or miss data. (orig.)

  8. Comparative availability and reliability assessment of design options for the secondary sodium loops of the EFR

    International Nuclear Information System (INIS)

    Pamme, H.

    1989-01-01

    The EFR (European Fast Reactor) project has entered a conceptual study period where different design alternatives are compared concerning feasibility, safety and economic aspects. This paper describes a comparative probabilistic availability and reliability assessment of alternative design options for the secondary sodium loops. These loops will provide heat transfer from the reactor pool to the water-steam (power generating) side. So a high operational availability of the secondary loops during plant lifetime is essential for economic power generation. Additionally a high reliability is required to fulfill the operational decay heat removal function in case of a reactor trip. Availabilities and reliabilities of the different options were assessed using failure mode and effect analysis and the fault tree method. (orig.)

  9. A set of key questions to assess the stress among bank employees and its reliability

    Directory of Open Access Journals (Sweden)

    Alice Mannocci

    2017-03-01

    Full Text Available The aims of the present study are: to realize a tool, clear and helpful, to assess the occupational distress level in bank employees in Italy; secondly to assess the reliability of the tool. Eight sentences were considered after a consensus meeting that involved different professional figures. 70 questionnaires were collected. The overall Cronbach’s alpha was 0.596, a sufficient reliability was found. The elimination of one sentences (“I haven’t time to dedicate myself to my hobbies/activities/stuff” increases alpha’s value from 0.596 to 0.620, and thus reach fully sufficient score. The claim “The pace of change on work place exceeds my capacity for adaptation” maximises the change of the level of reliability (Inter item Correlation = 0.528.

  10. Department of Defense need for a micro-electromechanical systems (MEMS) reliability assessment program

    Science.gov (United States)

    Zunino, James L., III; Skelton, Donald

    2005-01-01

    As the United States (U.S.) Army transforms into a lighter, more lethal, and more agile force, the technologies that support both legacy and emerging weapon systems must decrease in size while increasing in intelligence. Micro-electromechanical systems (MEMS) are one such technology that the Army as well as entire DOD will heavily rely on in achieving these objectives. Current and future military applications of MEMS devices include safety and arming devices, guidance systems, sensors/detectors, inertial measurement units, tracking devices, radio frequency devices, wireless radio frequency identification (RFID), etc. Even though the reliance on MEMS devices has been increasing, there have been no studies performed to determine their reliability and failure mechanisms. Furthermore, no standardized test protocols exist for assessing reliability. Accordingly, the U.S. Army Corrosion Office at Picatinny, NJ has initiated the MEMS Reliability Assessment Program to address this issue.

  11. Reliability of risk assessment measures used in sexually violent predator proceedings.

    Science.gov (United States)

    Miller, Cailey S; Kimonis, Eva R; Otto, Randy K; Kline, Suzonne M; Wasserman, Adam L

    2012-12-01

    The field interrater reliability of three assessment tools frequently used by mental health professionals when evaluating sex offenders' risk for reoffending--the Psychopathy Checklist-Revised (PCL-R), the Minnesota Sex Offender Screening Tool-Revised (MnSOST-R) and the Static-99-was examined within the context of sexually violent predator program proceedings. Rater agreement was highest for the Static--99 (intraclass correlation coefficient [ICC₁] = .78) and lowest for the PCL-R (ICC₁ = .60; MnSOST-R ICC₁ = .74), although all instruments demonstrated lower field reliability than that reported in their test manuals. Findings raise concerns about the reliability of risk assessment tools that are used to inform judgments of risk in high-stake sexually violent predator proceedings. Implications for future research and suggestions for improving evaluator training to increase accuracy when informing legal decision making are discussed.

  12. Designing the database for a reliability aware Model-Based System Engineering process

    International Nuclear Information System (INIS)

    Cressent, Robin; David, Pierre; Idasiak, Vincent; Kratz, Frederic

    2013-01-01

    This article outlines the need for a reliability database to implement model-based description of components failure modes and dysfunctional behaviors. We detail the requirements such a database should honor and describe our own solution: the Dysfunctional Behavior Database (DBD). Through the description of its meta-model, the benefits of integrating the DBD in the system design process is highlighted. The main advantages depicted are the possibility to manage feedback knowledge at various granularity and semantic levels and to ease drastically the interactions between system engineering activities and reliability studies. The compliance of the DBD with other reliability database such as FIDES is presented and illustrated. - Highlights: ► Model-Based System Engineering is more and more used in the industry. ► It results in a need for a reliability database able to deal with model-based description of dysfunctional behavior. ► The Dysfunctional Behavior Database aims to fulfill that need. ► It helps dealing with feedback management thanks to its structured meta-model. ► The DBD can profit from other reliability database such as FIDES.

  13. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan.

    Science.gov (United States)

    Moore, Amy Lawson; Miller, Terissa M

    2018-01-01

    The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.

  14. Translation, cross-cultural adaptation to Brazilian- Portuguese and reliability analysis of the instrument Rapid Entire Body Assessment-REBA

    Directory of Open Access Journals (Sweden)

    Andressa M. Lamarão

    2014-06-01

    Full Text Available Background: Observational instruments, such as the Rapid Entire Body Assessment, quickly assess biomechanical risks present in the workplace. However, in order to use these instruments, it is necessary to conduct the translational/cross-cultural adaptation of the instrument and test its measurement properties. Objectives: To perform the translation and the cross-cultural adaptation to Brazilian-Portuguese and test the reliability of the REBA instrument. Method: The procedures of translation and cross-cultural adaptation to Brazilian-Portuguese were conducted following proposed guidelines that involved translation, synthesis of translations, back translation, committee review and testing of the pre-final version. In addition, reliability and the intra- and inter-rater percent agreement were obtained with the Linear Weighted Kappa Coefficient that was associated with the 95% Confidence Interval and the cross tabulation 2×2. Results : The procedures for translation and adaptation were adequate and the necessary adjustments were conducted on the instrument. The intra- and inter-rater reliability showed values of 0.104 to 0.504, respectively, ranging from very poor to moderate. The percentage agreement values ranged from 5.66% to 69.81%. The percentage agreement was closer to 100% at the item 'upper arm' (69.81% for the Intra-rater 1 and at the items 'legs' and 'upper arm' for the Intra-rater 2 (62.26%. Conclusions: The processes of translation and cross-cultural adaptation were conducted on the REBA instrument and the Brazilian version of the instrument was obtained. However, despite the reliability of the tests used to correct the translated and adapted version, the reliability values are unacceptable according to the guidelines standard, indicating that the reliability must be re-evaluated. Therefore, caution in the interpretation of the biomechanical risks measured by this instrument should be taken.

  15. Translation, cross-cultural adaptation to Brazilian- Portuguese and reliability analysis of the instrument Rapid Entire Body Assessment-REBA

    Science.gov (United States)

    Lamarão, Andressa M.; Costa, Lucíola C. M.; Comper, Maria L. C.; Padula, Rosimeire S.

    2014-01-01

    Background: Observational instruments, such as the Rapid Entire Body Assessment, quickly assess biomechanical risks present in the workplace. However, in order to use these instruments, it is necessary to conduct the translational/cross-cultural adaptation of the instrument and test its measurement properties. Objectives: To perform the translation and the cross-cultural adaptation to Brazilian-Portuguese and test the reliability of the REBA instrument. Method: The procedures of translation and cross-cultural adaptation to Brazilian-Portuguese were conducted following proposed guidelines that involved translation, synthesis of translations, back translation, committee review and testing of the pre-final version. In addition, reliability and the intra- and inter-rater percent agreement were obtained with the Linear Weighted Kappa Coefficient that was associated with the 95% Confidence Interval and the cross tabulation 2×2. Results : The procedures for translation and adaptation were adequate and the necessary adjustments were conducted on the instrument. The intra- and inter-rater reliability showed values of 0.104 to 0.504, respectively, ranging from very poor to moderate. The percentage agreement values ranged from 5.66% to 69.81%. The percentage agreement was closer to 100% at the item 'upper arm' (69.81%) for the Intra-rater 1 and at the items 'legs' and 'upper arm' for the Intra-rater 2 (62.26%). Conclusions: The processes of translation and cross-cultural adaptation were conducted on the REBA instrument and the Brazilian version of the instrument was obtained. However, despite the reliability of the tests used to correct the translated and adapted version, the reliability values are unacceptable according to the guidelines standard, indicating that the reliability must be re-evaluated. Therefore, caution in the interpretation of the biomechanical risks measured by this instrument should be taken. PMID:25003273

  16. Validity and reliability of the Cognitive Complaints in Bipolar Disorder Rating Assessment (COBRA) in Japanese patients with bipolar disorder.

    Science.gov (United States)

    Toyoshima, Kuniyoshi; Fujii, Yutaka; Mitsui, Nobuyuki; Kako, Yuki; Asakura, Satoshi; Martinez-Aran, Anabel; Vieta, Eduard; Kusumi, Ichiro

    2017-08-01

    In Japan, there are currently no reliable rating scales for the evaluation of subjective cognitive impairment in patients with bipolar disorder. We studied the relationship between the Japanese version of the Cognitive Complaints in Bipolar Disorder Rating Assessment (COBRA) and objective cognitive assessments in patients with bipolar disorder. We further assessed the reliability and validity of the COBRA. Forty-one patients, aged 16-64, in a remission period of bipolar disorder were recruited from Hokkaido University Hospital in Sapporo, Japan. The COBRA (Japanese version) and Frankfurt Complaint Questionnaire (FCQ), the gold standard in subjective cognitive assessment, were administered. A battery of neuropsychological tests was employed to measure objective cognitive impairment. Correlations among the COBRA, FCQ, and neuropsychological tests were determined using Spearman's correlation coefficient. The Japanese version of the COBRA had high internal consistency, good retest reliability, and concurrent validity-as indicated by a strong correlation with the FCQ. A significant correlation was also observed between the COBRA and objective cognitive measurements of processing speed. These findings are the first to demonstrate that the Japanese version of the COBRA may be clinically useful as a subjective cognitive impairment rating scale in Japanese patients with bipolar disorder. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  17. Reliability of System Identification Techniques to Assess Standing Balance in Healthy Elderly.

    Directory of Open Access Journals (Sweden)

    Jantsje H Pasma

    Full Text Available System identification techniques have the potential to assess the contribution of the underlying systems involved in standing balance by applying well-known disturbances. We investigated the reliability of standing balance parameters obtained with multivariate closed loop system identification techniques.In twelve healthy elderly balance tests were performed twice a day during three days. Body sway was measured during two minutes of standing with eyes closed and the Balance test Room (BalRoom was used to apply four disturbances simultaneously: two sensory disturbances, to the proprioceptive and the visual system, and two mechanical disturbances applied at the leg and trunk segment. Using system identification techniques, sensitivity functions of the sensory disturbances and the neuromuscular controller were estimated. Based on the generalizability theory (G theory, systematic errors and sources of variability were assessed using linear mixed models and reliability was assessed by computing indexes of dependability (ID, standard error of measurement (SEM and minimal detectable change (MDC.A systematic error was found between the first and second trial in the sensitivity functions. No systematic error was found in the neuromuscular controller and body sway. The reliability of 15 of 25 parameters and body sway were moderate to excellent when the results of two trials on three days were averaged. To reach an excellent reliability on one day in 7 out of 25 parameters, it was predicted that at least seven trials must be averaged.This study shows that system identification techniques are a promising method to assess the underlying systems involved in standing balance in elderly. However, most of the parameters do not appear to be reliable unless a large number of trials are collected across multiple days. To reach an excellent reliability in one third of the parameters, a training session for participants is needed and at least seven trials of two

  18. Reliability tests and guidelines for B-mode ultrasound assessment of central adiposity.

    Science.gov (United States)

    Stoner, Lee; Chinn, Victoria; Cornwall, Jon; Meikle, Grant; Page, Rachel; Lambrick, Danielle; Faulkner, James

    2015-11-01

    Ultrasound represents a validated and relatively inexpensive diagnostic device for assessing central adiposity; however, widespread adoption has been impeded by the lack of reliable standard operating procedures. To examine the reliability of, and describe guidelines for, ultrasound-derived recording of intra-abdominal fat thickness (IAT) and maximal preperitoneal fat thickness (PFT). Ultrasound scans were obtained from 20 adults (50% female, 26 ± 7 years, 24·5 kg/m(2) ) on three different mornings. IAT was assessed 2 cm above the umbilicus (transverse plane) measuring from linea alba to: (i) anterior aorta, (ii) posterior aorta and (iii) anterior aspect of the vertebral column. PFT was measured from linea alba to visceral peritoneum in (i) sagittal and (ii) transverse planes, immediately over and inferior to the xiphi-sternum, respectively. For IAT, the criterion intraclass correlation coefficient (ICC) of 0·75 was exceeded for measurements to anterior aorta (0·95), posterior aorta (0·94) and vertebra (0·96). The reliability coefficient expressed as a percentage of the mean (RC%) was lowest (better) for measurement to vertebrae (9·8%). For PFT, mean thickness was comparable for sagittal (1·74 cm) and transverse (1·76 cm) planes; ICC values were also comparable for both planes (0·98 vs. 0·98, respectively), as were RC% (7·5% vs. 7·1%, respectively). IAT assessments to the vertebra were marginally more reliable than those to other structures. While PFT assessments were equally reliable for both measurements planes, precise probe placement was easier for the sagittal plane. Based on these findings, guidelines for the reliable measurement of central adiposity using ultrasound are presented. © 2015 Stichting European Society for Clinical Investigation Journal Foundation.

  19. Assessing Academic Advising Outcomes Using Social Cognitive Theory: A Validity and Reliability Study

    Science.gov (United States)

    Erlich, Richard J.; Russ-Eft, Darlene F.

    2012-01-01

    The validity and reliability of three instruments, the "Counselor Rubric for Gauging Student Understanding of Academic Planning," micro-analytic questions, and the "Student Survey for Understanding Academic Planning," all based on social cognitive theory, were tested as means to assess self-efficacy and self-regulated learning in college academic…

  20. Validity and inter-observer reliability of subjective hand-arm vibration assessments

    NARCIS (Netherlands)

    Coenen, P.; Formanoy, M.; Douwes, M.; Bosch, T.; Kraker, H. de

    2014-01-01

    Exposure to mechanical vibrations at work (e.g., due to handling powered tools) is a potential occupational risk as it may cause upper extremity complaints. However, reliable and valid assessment methods for vibration exposure at work are lacking. Measuring hand-arm vibration objectively is often

  1. Estimating the Reliability of Aggregated and Within-Person Centered Scores in Ecological Momentary Assessment

    Science.gov (United States)

    Huang, Po-Hsien; Weng, Li-Jen

    2012-01-01

    A procedure for estimating the reliability of test scores in the context of ecological momentary assessment (EMA) was proposed to take into account the characteristics of EMA measures. Two commonly used test scores in EMA were considered: the aggregated score (AGGS) and the within-person centered score (WPCS). Conceptually, AGGS and WPCS represent…

  2. The inventory for déjà vu experiences assessment. Development, utility, reliability, and validity

    NARCIS (Netherlands)

    Sno, H. N.; Schalken, H. F.; de Jonghe, F.; Koeter, M. W.

    1994-01-01

    In this article the development, utility, reliability, and validity of the Inventory for Déjà vu Experiences Assessment (IDEA) are described. The IDEA is a 23-item self-administered questionnaire consisting of a general section of nine questions and qualitative section of 14 questions. The latter

  3. Analysis of the Reliability and Validity of a Mentor's Assessment for Principal Internships

    Science.gov (United States)

    Koonce, Glenn L.; Kelly, Michael D.

    2014-01-01

    In this study, researchers analyzed the reliability and validity of the mentor's assessment for principal internships at a university in the Southeast region of the United States. The results of the study yielded how trustworthy and dependable the instrument is and the effectiveness of the instrument in the current principal preparation program.…

  4. Examining the Reliability and Validity of the Effective Behavior Support Self-Assessment Survey

    Science.gov (United States)

    Solomon, Benjamin G.; Tobin, Kevin G.; Schutte, Gregory M.

    2015-01-01

    The Effective Behavior Support Self-Assessment Survey (SAS; Sugai, Horner, & Todd, 2003) is designed to measure perceived Positive Behavior Interventions and Supports (PBIS) implementation and identify priorities for improvement. Despite its longevity, little published research exists documenting its reliability or validity for these purposes.…

  5. Factor Structure and Reliability of Test Items for Saudi Teacher Licence Assessment

    Science.gov (United States)

    Alsadaawi, Abdullah Saleh

    2017-01-01

    The Saudi National Assessment Centre administers the Computer Science Teacher Test for teacher certification. The aim of this study is to explore gender differences in candidates' scores, and investigate dimensionality, reliability, and differential item functioning using confirmatory factor analysis and item response theory. The confirmatory…

  6. New application of dynamic reliability assessment of the mid-loop operation

    International Nuclear Information System (INIS)

    Moosung, Jae; Goon Cherl Park; Chang Hyun Chung

    1995-01-01

    This paper presents a new approach for assessing the dynamic reliability in a complex system such as a nuclear power plant. The method is applied to a dynamic analysis of the potential accident sequences that may occur during mid-loop operation

  7. Reliability of the craniocervical posture assessment: visual and angular measurements using photographs and radiographs.

    Science.gov (United States)

    Gadotti, Inae C; Armijo-Olivo, Susan; Silveira, Anelise; Magee, David

    2013-01-01

    The purposes of this study were to determine the intrarater and interrater reliability of the craniocervical posture in a sagittal view using quantitative measurements on photographs and radiographs and to determine the agreement of the visual assessment of posture between raters. One photograph and 1 radiograph of the sagittal craniocervical posture were simultaneously taken from 39 healthy female subjects. Three angles were measured on the photographs and 10 angles on the radiographs of 22 subjects using Alcimage software (Alcimage; Uberlândia, MG, Brazil). Two repeated measurements were performed by 2 raters. The measurements were compared within and between raters to test the intrarater and interrater reliability, respectively. Intraclass correlation coefficient and SEM were used. κ Agreement was calculated for the visual assessment of 39 subjects using photographs and radiographs between 2 raters. Good to excellent intrarater and interrater intraclass correlation coefficient values were found on both photographs and radiographs. Interrater SEM was large and clinically significant for cervical lordosis photogrammetry and for 1 angle measuring cervical lordosis on radiographs. Interrater κ agreement for the visual assessment using photographs was poor (κ = 0.37). The raters were reliable to measure angles in photographs and radiographs to quantify craniocervical posture with exception of 2 angles measuring lordosis of the cervical spine when compared between raters. The visual assessment of posture between raters was not reliable. © 2013. Published by National University of Health Sciences All rights reserved.

  8. Non-Parametric Bayesian Updating within the Assessment of Reliability for Offshore Wind Turbine Support Structures

    DEFF Research Database (Denmark)

    Ramirez, José Rangel; Sørensen, John Dalsgaard

    2011-01-01

    This work illustrates the updating and incorporation of information in the assessment of fatigue reliability for offshore wind turbine. The new information, coming from external and condition monitoring can be used to direct updating of the stochastic variables through a non-parametric Bayesian u...

  9. Reliability of the Life Satisfaction Questionnaire to assess patients with chronic musculoskeletal pain

    NARCIS (Netherlands)

    Boonstra, Anne M.; Reneman, Michiel F.; Posthumus, Jitze B.; Stewart, Roy E.; Schiphorst Preuper, Henrica R.

    The aim of this study was to determine the reliability of the Life Satisfaction Questionnaire, Dutch version (LSQ-DV), to assess chronic pain patients. The study was designed as test-retest. The setting was the general rehabilitation centre. There were 51 patients over 18 years of age, suffering

  10. Test-Retest Reliability of the Preschool Age Psychiatric Assessment (PAPA)

    Science.gov (United States)

    Egger, Helen Link; Erkanli, Alaattin; Keeler, Gordon; Potts, Edward; Walter, Barbara Keith; Angold, Adrian

    2006-01-01

    Objective: To examine the test-retest reliability of a new interviewer-based psychiatric diagnostic measure (the Preschool Age Psychiatric Assessment) for use with parents of preschoolers 2 to 5 years old. Method: A total of 1,073 parents of children attending a large pediatric clinic completed the Child Behavior Checklist 1 1/2-5. For 18 months,…

  11. Interrater reliability assessment using the Test of Gross Motor Development-2.

    Science.gov (United States)

    Barnett, Lisa M; Minto, Christine; Lander, Natalie; Hardy, Louise L

    2014-11-01

    The aim was to examine interrater reliability of the object control subtest from the Test of Gross Motor Development-2 by live observation in a school field setting. Reliability Study--cross sectional. Raters were rated on their ability to agree on (1) the raw total for the six object control skills; (2) each skill performance and (3) the skill components. Agreement for the object control subtest and the individual skills was assessed by an intraclass correlation (ICC) and a kappa statistic assessed for skill component agreement. A total of 37 children (65% girls) aged 4-8 years (M = 6.2, SD = 0.8) were assessed in six skills by two raters; equating to 222 skill tests. Interrater reliability was excellent for the object control subset (ICC = 0.93), and for individual skills, highest for the dribble (ICC = 0.94) followed by strike (ICC = 0.85), overhand throw (ICC = 0.84), underhand roll (ICC = 0.82), kick (ICC = 0.80) and the catch (ICC = 0.71). The strike and the throw had more components with less agreement. Even though the overall subtest score and individual skill agreement was good, some skill components had lower agreement, suggesting these may be more problematic to assess. This may mean some skill components need to be specified differently in order to improve component reliability. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  12. Reliability Assessment of SiC Power MOSFETs From The End User's Perspective

    DEFF Research Database (Denmark)

    Karaventzas, Vasilios Dimitris; Nawaz, Muhammad; Iannuzzo, Francesco

    2016-01-01

    The reliability of commercial Silicon Carbide (SiC) Metal-Oxide-Semiconductor Field-Effect Transistors (MOSFETs) is investigated, and comparative assessment is performed under various test environments. The MOSFETs are tested both regarding the electrical properties of the dies and the packaging...

  13. A Motor Speech Assessment for Children with Severe Speech Disorders: Reliability and Validity Evidence

    Science.gov (United States)

    Strand, Edythe A.; McCauley, Rebecca J.; Weigand, Stephen D.; Stoeckel, Ruth E.; Baas, Becky S.

    2013-01-01

    Purpose: In this article, the authors report reliability and validity evidence for the Dynamic Evaluation of Motor Speech Skill (DEMSS), a new test that uses dynamic assessment to aid in the differential diagnosis of childhood apraxia of speech (CAS). Method: Participants were 81 children between 36 and 79 months of age who were referred to the…

  14. Reliability of ^1^H NMR analysis for assessment of lipid oxidation at frying temperatures

    Science.gov (United States)

    The reliability of a method using ^1^H NMR analysis for assessment of oil oxidation at a frying temperature was examined. During heating and frying at 180 °C, changes of soybean oil signals in the ^1^H NMR spectrum including olefinic (5.16-5.30 ppm), bisallylic (2.70-2.88 ppm), and allylic (1.94-2.1...

  15. Brief Assessment of Motor Function: Content Validity and Reliability of the Upper Extremity Gross Motor Scale

    Science.gov (United States)

    Cintas, Holly Lea; Parks, Rebecca; Don, Sarah; Gerber, Lynn

    2011-01-01

    Content validity and reliability of the Brief Assessment of Motor Function (BAMF) Upper Extremity Gross Motor Scale (UEGMS) were evaluated in this prospective, descriptive study. The UEGMS is one of five BAMF ordinal scales designed for quick documentation of gross, fine, and oral motor skill levels. Designed to be independent of age and…

  16. Investigating the reliability and validity of the waterlow risk assessment scale: a literature review.

    LENUS (Irish Health Repository)

    Walsh, Breda

    2012-02-01

    The aim of this review was to examine health literature on the reliability and validity of the Waterlow pressure sore assessment scale. A systematic review of published studies relating to the topic was conducted and literature was examined for its relevancy to the topic under investigation. Findings suggest that despite the availability of over 40 assessment tools, the Waterlow assessment scale is the most frequently used by health care staff. Research suggests that the Waterlow Scale is an unreliable method of assessing individuals at risk of pressure sore development with all studies indicating a poor interrater reliability status. Its validity has also been criticized because of its high-sensitivity but low-specificity levels.

  17. Investigating the reliability and validity of the waterlow risk assessment scale: a literature review.

    LENUS (Irish Health Repository)

    Walsh, Breda

    2011-05-01

    The aim of this review was to examine health literature on the reliability and validity of the Waterlow pressure sore assessment scale. A systematic review of published studies relating to the topic was conducted and literature was examined for its relevancy to the topic under investigation. Findings suggest that despite the availability of over 40 assessment tools, the Waterlow assessment scale is the most frequently used by health care staff. Research suggests that the Waterlow Scale is an unreliable method of assessing individuals at risk of pressure sore development with all studies indicating a poor interrater reliability status. Its validity has also been criticized because of its high-sensitivity but low-specificity levels.

  18. An objective spinal motion imaging assessment (OSMIA): reliability, accuracy and exposure data.

    Science.gov (United States)

    Breen, Alan C; Muggleton, Jennifer M; Mellor, Fiona E

    2006-01-04

    Minimally-invasive measurement of continuous inter-vertebral motion in clinical settings is difficult to achieve. This paper describes the reliability, validity and radiation exposure levels in a new Objective Spinal Motion Imaging Assessment system (OSMIA) based on low-dose fluoroscopy and image processing. Fluoroscopic sequences in coronal and sagittal planes were obtained from 2 calibration models using dry lumbar vertebrae, plus the lumbar spines of 30 asymptomatic volunteers. Calibration model 1 (mobile) was screened upright, in 7 inter-vertebral positions. The volunteers and calibration model 2 (fixed) were screened on a motorized table comprising 2 horizontal sections, one of which moved through 80 degrees. Model 2 was screened during motion 5 times and the L2-S1 levels of the volunteers twice. Images were digitised at 5fps. Inter-vertebral motion from model 1 was compared to its pre-settings to investigate accuracy. For volunteers and model 2, the first digitised image in each sequence was marked with templates. Vertebrae were tracked throughout the motion using automated frame-to-frame registration. For each frame, vertebral angles were subtracted giving inter-vertebral motion graphs. Volunteer data were acquired twice on the same day and analysed by two blinded observers. The root-mean-square (RMS) differences between paired data were used as the measure of reliability. RMS difference between reference and computed inter-vertebral angles in model 1 was 0.32 degrees for side-bending and 0.52 degrees for flexion-extension. For model 2, X-ray positioning contributed more to the variance of range measurement than did automated registration. For volunteer image sequences, RMS inter-observer variation in intervertebral motion range in the coronal plane was 1.86 degrees and intra-subject biological variation was between 2.75 degrees and 2.91 degrees. RMS inter-observer variation in the sagittal plane was 1.94 degrees. Radiation dosages in each view were below

  19. An objective spinal motion imaging assessment (OSMIA: reliability, accuracy and exposure data

    Directory of Open Access Journals (Sweden)

    Mellor Fiona E

    2006-01-01

    Full Text Available Abstract Background Minimally-invasive measurement of continuous inter-vertebral motion in clinical settings is difficult to achieve. This paper describes the reliability, validity and radiation exposure levels in a new Objective Spinal Motion Imaging Assessment system (OSMIA based on low-dose fluoroscopy and image processing. Methods Fluoroscopic sequences in coronal and sagittal planes were obtained from 2 calibration models using dry lumbar vertebrae, plus the lumbar spines of 30 asymptomatic volunteers. Calibration model 1 (mobile was screened upright, in 7 inter-vertebral positions. The volunteers and calibration model 2 (fixed were screened on a motorised table comprising 2 horizontal sections, one of which moved through 80 degrees. Model 2 was screened during motion 5 times and the L2-S1 levels of the volunteers twice. Images were digitised at 5fps. Inter-vertebral motion from model 1 was compared to its pre-settings to investigate accuracy. For volunteers and model 2, the first digitised image in each sequence was marked with templates. Vertebrae were tracked throughout the motion using automated frame-to-frame registration. For each frame, vertebral angles were subtracted giving inter-vertebral motion graphs. Volunteer data were acquired twice on the same day and analysed by two blinded observers. The root-mean-square (RMS differences between paired data were used as the measure of reliability. Results RMS difference between reference and computed inter-vertebral angles in model 1 was 0.32 degrees for side-bending and 0.52 degrees for flexion-extension. For model 2, X-ray positioning contributed more to the variance of range measurement than did automated registration. For volunteer image sequences, RMS inter-observer variation in intervertebral motion range in the coronal plane was 1.86 degreesand intra-subject biological variation was between 2.75 degrees and 2.91 degrees. RMS inter-observer variation in the sagittal plane was 1

  20. Assessing Reliability of Two Versions of Vocabulary Levels Tests in Iranian Context

    Directory of Open Access Journals (Sweden)

    Aso Bayazidi

    2017-02-01

    Full Text Available This study examined the equivalence and reliability of the two versions of the Vocabulary Levels Test in an Iranian context. This study was motivated by the fact that the Vocabulary Levels test is increasingly being used in Iran for both research and pedagogical purposes without having been checked for validity and reliability in this context. The equivalence and reliability of the two versions of the test were examined through the parallel-form approach to reliability in Classical True Score theory. Seventy-five intermediate learners of English as a foreign language at the Iran Language Institute took the two versions of the test with one week interval between the two administrations in a counterbalanced fashion. To examine the equivalence of the two versions, the means and variances of the scores obtained for the two tests were compared using paired-sample t-test and one-way ANOVA, respectively. The results of the analyses indicated that the difference between the means of the two versions was significant, and the two versions cannot be considered as parallel forms. To assess the reliability of the two versions, the correlation between the scores obtained from them was estimated using Pearson Product Moment correlation. The results of the analyses showed that the two versions are highly correlated and are reliable tests. It is concluded that the two versions should not be treated as equivalent in longitudinal and gain score studies.

  1. Physics-based process modeling, reliability prediction, and design guidelines for flip-chip devices

    Science.gov (United States)

    Michaelides, Stylianos

    Flip Chip on Board (FCOB) and Chip-Scale Packages (CSPs) are relatively new technologies that are being increasingly used in the electronic packaging industry. Compared to the more widely used face-up wirebonding and TAB technologies, flip-chips and most CSPs provide the shortest possible leads, lower inductance, higher frequency, better noise control, higher density, greater input/output (I/O), smaller device footprint and lower profile. However, due to the short history and due to the introduction of several new electronic materials, designs, and processing conditions, very limited work has been done to understand the role of material, geometry, and processing parameters on the reliability of flip-chip devices. Also, with the ever-increasing complexity of semiconductor packages and with the continued reduction in time to market, it is too costly to wait until the later stages of design and testing to discover that the reliability is not satisfactory. The objective of the research is to develop integrated process-reliability models that will take into consideration the mechanics of assembly processes to be able to determine the reliability of face-down devices under thermal cycling and long-term temperature dwelling. The models incorporate the time and temperature-dependent constitutive behavior of various materials in the assembly to be able to predict failure modes such as die cracking and solder cracking. In addition, the models account for process-induced defects and macro-micro features of the assembly. Creep-fatigue and continuum-damage mechanics models for the solder interconnects and fracture-mechanics models for the die have been used to determine the reliability of the devices. The results predicted by the models have been successfully validated against experimental data. The validated models have been used to develop qualification and test procedures for implantable medical devices. In addition, the research has helped develop innovative face

  2. Reliability of an fMRI Paradigm for Emotional Processing in a Multisite Longitudinal Study

    Science.gov (United States)

    Gee, Dylan G.; McEwen, Sarah C.; Forsyth, Jennifer K.; Haut, Kristen M.; Bearden, Carrie E.; Addington, Jean; Goodyear, Bradley; Cadenhead, Kristin S.; Mirzakhanian, Heline; Cornblatt, Barbara A.; Olvet, Doreen; Mathalon, Daniel H.; McGlashan, Thomas H.; Perkins, Diana O.; Belger, Aysenil; Seidman, Larry J.; Thermenos, Heidi; Tsuang, Ming T.; van Erp, Theo G.M.; Walker, Elaine F.; Hamann, Stephan; Woods, Scott W.; Constable, Todd; Cannon, Tyrone D.

    2015-01-01

    Multisite neuroimaging studies can facilitate the investigation of brain-related changes in many contexts, including patient groups that are relatively rare in the general population. Though multisite studies have characterized the reliability of brain activation during working memory and motor functional magnetic resonance imaging tasks, emotion processing tasks, pertinent to many clinical populations, remain less explored. A traveling participants study was conducted with eight healthy volunteers scanned twice on consecutive days at each of the eight North American Longitudinal Prodrome Study sites. Tests derived from generalizability theory showed excellent reliability in the amygdala (Eρ2=0.82), inferior frontal gyrus (IFG;Eρ2=0.83), anterior cingulate cortex (ACC;Eρ2=0.76), insula (Eρ2=0.85), and fusiform gyrus (Eρ2=0.91) for maximum activation and fair to excellent reliability in the amygdala (Eρ2=0.44), IFG (Eρ2=0.48), ACC (Eρ2=0.55), insula (Eρ2=0.42), and fusiform gyrus (Eρ2=0.83) for mean activation across sites and test days. For the amygdala, habituation (Eρ2=0.71) was more stable than mean activation. In a second investigation, data from 111 healthy individuals across sites were aggregated in a voxelwise, quantitative meta-analysis. When compared with a mixed effects model controlling for site, both approaches identified robust activation in regions consistent with expected results based on prior single-site research. Overall, regions central to emotion processing showed strong reliability in the traveling participants study and robust activation in the aggregation study. These results support the reliability of blood oxygen level-dependent signal in emotion processing areas across different sites and scanners and may inform future efforts to increase efficiency and enhance knowledge of rare conditions in the population through multisite neuroimaging paradigms. PMID:25821147

  3. A prospective study assessing agreement and reliability of a geriatric evaluation

    OpenAIRE

    Locatelli, Isabella; Monod, St?fanie; Cornuz, Jacques; B?la, Christophe J.; Senn, Nicolas

    2017-01-01

    Background The present study takes place within a geriatric program, aiming at improving the diagnosis and management of geriatric syndromes in primary care. Within this program it was of prime importance to be able to rely on a robust and reproducible geriatric consultation to use as a gold standard for evaluating a primary care brief assessment tool. The specific objective of the present study was thus assessing the agreement and reliability of a comprehensive geriatric consultation. Method...

  4. Reliability of the Crowe und Hartofilakidis classifications used in the assessment of the adult dysplastic hip

    Energy Technology Data Exchange (ETDEWEB)

    Decking, Ralf; Brunner, Alexander; Puhl, Wolfhart [University of Ulm, Orthopaedic Department, RKU, Ulm (Germany); Decking, Jens [Johannes Gutenberg University School of Medicine, Department of Orthopaedic Surgery, Mainz (Germany); Guenther, Klaus-Peter [University of Ulm, Orthopaedic Department, RKU, Ulm (Germany); University-Hospital Carl Gustav Carus, Department of Orthopaedics, Dresden (Germany)

    2006-05-15

    To assess the inter-observer and intra-observer reliability of two commonly used radiographic classification systems in the evaluation of hip dysplasia in skeletally mature adults. Three observers with different levels of training independently classified 62 dysplastic hips on 51 standard anteriorposterior pelvis radiographs according to the criteria defined by Crowe and by Hartofilakidis. To assess intra-observer reliability, the same radiographs were reviewed 3 months later by the same observers. At the time of the radiographic examination, the mean age of the 51 patients had been 54 years (range 18-82 years). A high correlation concerning the inter- and intra-observer reliability of both systems was demonstrated. Inter-observer reliability displayed a weighted kappa coefficient of 0.82 for the Crowe and 0.75 for the Hartofilakidis classification. Intra-observer reliability showed a kappa coefficient of 0.86 and 0.79, respectively. Both classification systems can be recommended to compare collectives of adult patients with congenital dysplasia of the hip. However, for future clinical practice, it would be advisable to agree on one universally accepted system as a standard in the literature. (orig.)

  5. Reliability and validity of migraine disability assessment questionnaire-Thai version (Thai-MIDAS).

    Science.gov (United States)

    Seethong, Piman; Nimmannit, Akarin; Chaisewikul, Rungsan; Prayoonwiwat, Naraporn; Chotinaiwattarakul, Wattanachai

    2013-02-01

    To assess the validity and test-retest reliability of a Thai translation of the Migraine Disability Assessment (MIDAS) Questionnaire in Thai patients with migraine. Migraineurs from the Headache Clinic in Siriraj Hospital were recruited and asked to complete a 13-weeks diary and answered the Thai-MIDAS at once. Some participants were asked to provide the 2nd Thai-MIDAS in the next 2 weeks for test-retest reliability. Ninety-three patients had completed the 13-weeks diaries. Age range was 18-58 years with mean 37.69 +/- 9.60 years. All 5 items and the total score of Thai-MIDAS were moderately correlated with data from 13-weeks diary (Spearman's correlation coefficient = 0.32-0.62). The test-retest reliability of the total score of Thai-MIDAS in 30 patients demonstrated a highly reliable degree of intraclass correlation (ICC = 0.76, 95% CI 0.49-0.88). The present study reveals that the Thai-MIDAS has satisfactory validity and reliability in comparison with the original English MIDAS version.

  6. Effect of knee angle on neuromuscular assessment of plantar flexor muscles: A reliability study

    Science.gov (United States)

    Cornu, Christophe; Jubeau, Marc

    2018-01-01

    Introduction This study aimed to determine the intra- and inter-session reliability of neuromuscular assessment of plantar flexor (PF) muscles at three knee angles. Methods Twelve young adults were tested for three knee angles (90°, 30° and 0°) and at three time points separated by 1 hour (intra-session) and 7 days (inter-session). Electrical (H reflex, M wave) and mechanical (evoked and maximal voluntary torque, activation level) parameters were measured on the PF muscles. Intraclass correlation coefficients (ICC) and coefficients of variation were calculated to determine intra- and inter-session reliability. Results The mechanical measurements presented excellent (ICC>0.75) intra- and inter-session reliabilities regardless of the knee angle considered. The reliability of electrical measurements was better for the 90° knee angle compared to the 0° and 30° angles. Conclusions Changes in the knee angle may influence the reliability of neuromuscular assessments, which indicates the importance of considering the knee angle to collect consistent outcomes on the PF muscles. PMID:29596480

  7. Reliability of the Crowe und Hartofilakidis classifications used in the assessment of the adult dysplastic hip

    International Nuclear Information System (INIS)

    Decking, Ralf; Brunner, Alexander; Puhl, Wolfhart; Decking, Jens; Guenther, Klaus-Peter

    2006-01-01

    To assess the inter-observer and intra-observer reliability of two commonly used radiographic classification systems in the evaluation of hip dysplasia in skeletally mature adults. Three observers with different levels of training independently classified 62 dysplastic hips on 51 standard anteriorposterior pelvis radiographs according to the criteria defined by Crowe and by Hartofilakidis. To assess intra-observer reliability, the same radiographs were reviewed 3 months later by the same observers. At the time of the radiographic examination, the mean age of the 51 patients had been 54 years (range 18-82 years). A high correlation concerning the inter- and intra-observer reliability of both systems was demonstrated. Inter-observer reliability displayed a weighted kappa coefficient of 0.82 for the Crowe and 0.75 for the Hartofilakidis classification. Intra-observer reliability showed a kappa coefficient of 0.86 and 0.79, respectively. Both classification systems can be recommended to compare collectives of adult patients with congenital dysplasia of the hip. However, for future clinical practice, it would be advisable to agree on one universally accepted system as a standard in the literature. (orig.)

  8. Evolving inspection technologies for reliable condition assessment of components and plants

    International Nuclear Information System (INIS)

    Baldev Raj

    1994-01-01

    Condition assessment of components and plants are being done regularly in many an industry. The methodologies adopted are being continuously refined. However, each of these methodologies are being applied in isolation, without realizing the synergistic advantage we derive when a global approach is taken for condition assessment. Developments in a variety of fields, that have a definite bearing on the reliability of condition assessment, are not applied (or even thought that they could be applied) together. The possible impact of evolving technologies in enhancing the efficiency of condition assessment of components and plants are discussed. (author). 11 refs

  9. Process Mining Online Assessment Data

    Science.gov (United States)

    Pechenizkiy, Mykola; Trcka, Nikola; Vasilyeva, Ekaterina; van der Aalst, Wil; De Bra, Paul

    2009-01-01

    Traditional data mining techniques have been extensively applied to find interesting patterns, build descriptive and predictive models from large volumes of data accumulated through the use of different information systems. The results of data mining can be used for getting a better understanding of the underlying educational processes, for…

  10. Assessment of Counselors' Supervision Processes

    Science.gov (United States)

    Ünal, Ali; Sürücü, Abdullah; Yavuz, Mustafa

    2013-01-01

    The aim of this study is to investigate elementary and high school counselors' supervision processes and efficiency of their supervision. The interview method was used as it was thought to be better for realizing the aim of the study. The study group was composed of ten counselors who were chosen through purposeful sampling method. Data were…

  11. Methodology for risk assessment and reliability applied for pipeline engineering design and industrial valves operation

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Dierci [Universidade Federal Fluminense (UFF), Volta Redonda, RJ (Brazil). Escola de Engenharia Industrial e Metalurgia. Lab. de Sistemas de Producao e Petroleo e Gas], e-mail: dsilveira@metal.eeimvr.uff.br; Batista, Fabiano [CICERO, Rio das Ostras, RJ (Brazil)

    2009-07-01

    Two kinds of situations may be distinguished for estimating the operating reliability when maneuvering industrial valves and the probability of undesired events in pipelines and industrial plants: situations in which the risk is identified in repetitive cycles of operations and situations in which there is a permanent hazard due to project configurations introduced by decisions during the engineering design definition stage. The estimation of reliability based on the influence of design options requires the choice of a numerical index, which may include a composite of human operating parameters based on biomechanics and ergonomics data. We first consider the design conditions under which the plant or pipeline operator reliability concepts can be applied when operating industrial valves, and then describe in details the ergonomics and biomechanics risks that would lend itself to engineering design database development and human reliability modeling and assessment. This engineering design database development and reliability modeling is based on a group of engineering design and biomechanics parameters likely to lead to over-exertion forces and working postures, which are themselves associated with the functioning of a particular plant or pipeline. This approach to construct based on ergonomics and biomechanics for a more common industrial valve positioning in the plant layout is proposed through the development of a methodology to assess physical efforts and operator reach, combining various elementary operations situations. These procedures can be combined with the genetic algorithm modeling and four elements of the man-machine systems: the individual, the task, the machinery and the environment. The proposed methodology should be viewed not as competing to traditional reliability and risk assessment bur rather as complementary, since it provides parameters related to physical efforts values for valves operation and workspace design and usability. (author)

  12. Notes on human factors problems in process plant reliability and safety prediction

    International Nuclear Information System (INIS)

    Rasmussen, J.; Taylor, J.R.

    1976-09-01

    The basis for plant operator reliability evaluation is described. Principles for plant design, necessary to permit reliability evaluation, are outlined. Five approaches to the plant operator reliability problem are described. Case stories, illustrating operator reliability problems, are given. (author)

  13. Industrial process heat market assessment

    International Nuclear Information System (INIS)

    Bresnick, S.

    1981-12-01

    This report is designed to be a reference resource, giving a broad perspective of the potential HTGR market for industrial process heat. It is intended to serve as a briefing document for those wishing to obtain background information and also to serve as a starting point from which more detailed and refined studies may be undertaken. In doing so, the report presents a qualitative and quantitative description of the industrial process heat market in the US, provides a summary discussion of cogeneration experience to date, and outlines the existing institutional and financial framework for cogeneration. The intent is to give the reader an understanding of the current situation and experience in this area. The cogeneration area in particular is an evolving one because of regulations and tax laws, which are still in the process of being developed and interpreted. The report presents the latest developments in regulatory and legislative activities which are associated with that technology. Finally, the report presents a brief description of the three HTGR systems under study during the current fiscal year and describes the specific market characteristics which each application is designed to serve

  14. Industrial process heat market assessment

    Energy Technology Data Exchange (ETDEWEB)

    Bresnick, S.

    1981-12-01

    This report is designed to be a reference resource, giving a broad perspective of the potential HTGR market for industrial process heat. It is intended to serve as a briefing document for those wishing to obtain background information and also to serve as a starting point from which more detailed and refined studies may be undertaken. In doing so, the report presents a qualitative and quantitative description of the industrial process heat market in the US, provides a summary discussion of cogeneration experience to date, and outlines the existing institutional and financial framework for cogeneration. The intent is to give the reader an understanding of the current situation and experience in this area. The cogeneration area in particular is an evolving one because of regulations and tax laws, which are still in the process of being developed and interpreted. The report presents the latest developments in regulatory and legislative activities which are associated with that technology. Finally, the report presents a brief description of the three HTGR systems under study during the current fiscal year and describes the specific market characteristics which each application is designed to serve.

  15. Assessment of the accuracy and reliability of the Topcon CT80 non-contact tonometer.

    Science.gov (United States)

    Ogbuehi, Kelechi C

    2006-09-01

    The reliability of non-contact tonometers has been reported extensively in the literature. This study was designed to assess reliability of the new Topcon CT80 non-contact tonometer in normotensive subjects, using the Goldmann tonometer as the standard. The accuracy of the Topcon CT 80 non-contact tonometer was assessed by comparing its IOP assessments with those of the Goldmann applanation tonometer, on 60 right eyes of young healthy subjects with normal intraocular pressures. Each subject's intraocular pressure was assessed with each technique on two separate occasions, one week apart. The reliability of each technique was determined by the assessment of its inter-session repeatability using the Bland-Altman method. The 95 per cent limits of agreement for the two methods were also determined. No statistically significant difference was found between the average intraocular pressures measured with the two techniques (p > 0.05). The inter-session repeatability indices for the two techniques did not differ significantly (p > 0.05). The mean difference in intraocular measurements between the two techniques was 0.2 +/- 1.5 mmHg (mean +/- SD) and the 95 per cent limits of agreement were -3.14 and +2.74 mmHg, with the non-contact tonometer returning higher readings than the Goldmann tonometer. In this sample of normotensive subjects, the Topcon CT80 non-contact tonometer proved to be accurate and as reliable as the Goldmann tonometer in the assessment of intraocular pressure. Thus, it can be used as an objective clinical method for the assessment of normal intraocular pressure.

  16. Feasibility, reliability, and validity of a smartphone based application for the assessment of cognitive function in the elderly.

    Directory of Open Access Journals (Sweden)

    Robert M Brouillette

    Full Text Available While considerable knowledge has been gained through the use of established cognitive and motor assessment tools, there is a considerable interest and need for the development of a battery of reliable and validated assessment tools that provide real-time and remote analysis of cognitive and motor function in the elderly. Smartphones appear to be an obvious choice for the development of these "next-generation" assessment tools for geriatric research, although to date no studies have reported on the use of smartphone-based applications for the study of cognition in the elderly. The primary focus of the current study was to assess the feasibility, reliability, and validity of a smartphone-based application for the assessment of cognitive function in the elderly. A total of 57 non-demented elderly individuals were administered a newly developed smartphone application-based Color-Shape Test (CST in order to determine its utility in measuring cognitive processing speed in the elderly. Validity of this novel cognitive task was assessed by correlating performance on the CST with scores on widely accepted assessments of cognitive function. Scores on the CST were significantly correlated with global cognition (Mini-Mental State Exam: r = 0.515, p<0.0001 and multiple measures of processing speed and attention (Digit Span: r = 0.427, p<0.0001; Trail Making Test: r = -0.651, p<0.00001; Digit Symbol Test: r = 0.508, p<0.0001. The CST was not correlated with naming and verbal fluency tasks (Boston Naming Test, Vegetable/Animal Naming or memory tasks (Logical Memory Test. Test re-test reliability was observed to be significant (r = 0.726; p = 0.02. Together, these data are the first to demonstrate the feasibility, reliability, and validity of using a smartphone-based application for the purpose of assessing cognitive function in the elderly. The importance of these findings for the establishment of smartphone-based assessment batteries

  17. Interrater reliability of the mind map assessment rubric in a cohort of medical students

    Directory of Open Access Journals (Sweden)

    Zipp Genevieve

    2009-04-01

    Full Text Available Abstract Background Learning strategies are thinking tools that students can use to actively acquire information. Examples of learning strategies include mnemonics, charts, and maps. One strategy that may help students master the tsunami of information presented in medical school is the mind map learning strategy. Currently, there is no valid and reliable rubric to grade mind maps and this may contribute to their underutilization in medicine. Because concept maps and mind maps engage learners similarly at a metacognitive level, a valid and reliable concept map assessment scoring system was adapted to form the mind map assessment rubric (MMAR. The MMAR can assess mind map depth based upon concept-links, cross-links, hierarchies, examples, pictures, and colors. The purpose of this study was to examine interrater reliability of the MMAR. Methods This exploratory study was conducted at a US medical school as part of a larger investigation on learning strategies. Sixty-six (N = 66 first-year medical students were given a 394-word text passage followed by a 30-minute presentation on mind mapping. After the presentation, subjects were again given the text passage and instructed to create mind maps based upon the passage. The mind maps were collected and independently scored using the MMAR by 3 examiners. Interrater reliability was measured using the intraclass correlation coefficient (ICC statistic. Statistics were calculated using SPSS version 12.0 (Chicago, IL. Results Analysis of the mind maps revealed the following: concept-links ICC = .05 (95% CI, -.42 to .38, cross-links ICC = .58 (95% CI, .37 to .73, hierarchies ICC = .23 (95% CI, -.15 to .50, examples ICC = .53 (95% CI, .29 to .69, pictures ICC = .86 (95% CI, .79 to .91, colors ICC = .73 (95% CI, .59 to .82, and total score ICC = .86 (95% CI, .79 to .91. Conclusion The high ICC value for total mind map score indicates strong MMAR interrater reliability. Pictures and colors demonstrated moderate

  18. Interrater reliability of the mind map assessment rubric in a cohort of medical students.

    Science.gov (United States)

    D'Antoni, Anthony V; Zipp, Genevieve Pinto; Olson, Valerie G

    2009-04-28

    Learning strategies are thinking tools that students can use to actively acquire information. Examples of learning strategies include mnemonics, charts, and maps. One strategy that may help students master the tsunami of information presented in medical school is the mind map learning strategy. Currently, there is no valid and reliable rubric to grade mind maps and this may contribute to their underutilization in medicine. Because concept maps and mind maps engage learners similarly at a metacognitive level, a valid and reliable concept map assessment scoring system was adapted to form the mind map assessment rubric (MMAR). The MMAR can assess mind map depth based upon concept-links, cross-links, hierarchies, examples, pictures, and colors. The purpose of this study was to examine interrater reliability of the MMAR. This exploratory study was conducted at a US medical school as part of a larger investigation on learning strategies. Sixty-six (N = 66) first-year medical students were given a 394-word text passage followed by a 30-minute presentation on mind mapping. After the presentation, subjects were again given the text passage and instructed to create mind maps based upon the passage. The mind maps were collected and independently scored using the MMAR by 3 examiners. Interrater reliability was measured using the intraclass correlation coefficient (ICC) statistic. Statistics were calculated using SPSS version 12.0 (Chicago, IL). Analysis of the mind maps revealed the following: concept-links ICC = .05 (95% CI, -.42 to .38), cross-links ICC = .58 (95% CI, .37 to .73), hierarchies ICC = .23 (95% CI, -.15 to .50), examples ICC = .53 (95% CI, .29 to .69), pictures ICC = .86 (95% CI, .79 to .91), colors ICC = .73 (95% CI, .59 to .82), and total score ICC = .86 (95% CI, .79 to .91). The high ICC value for total mind map score indicates strong MMAR interrater reliability. Pictures and colors demonstrated moderate to strong interrater reliability. We conclude that the

  19. Reliability and validity of the Farsi version of the standardized assessment of personality-abbreviated scale

    Directory of Open Access Journals (Sweden)

    Maryam Sepehri

    2017-06-01

    Full Text Available Introduction: A short screening tool for high-risk individuals with personality disorder (PD is useful both for clinicians and researchers. The aim of this study was to assess the validity and reliability of the Farsi version of the Standardized Assessment of Personality-Abbreviated Scale (SAPAS. Methods: The original English version of the SAPAS questionnaire was translated into Farsi, and then, translated back into English by two professionals. A survey was then conducted using the questionnaire on 150 clients of primary health care centers in Tabriz, Iran. A total of 235 medical students were also studied for the reliability assessment of the questionnaire. The SAPAS was compared to the short form of Minnesota Multiphasic Personality Inventory (MMPI. The data analysis was performed using receiver operating characteristic (ROC curve technique, operating characteristic for diagnostic efficacy, Cronbach's alpha, and test-retest for reliability evaluation. Results: We found an area under the curve (AUC of 0.566 [95% confidence intervals (CI: 0.455-0.677]; sensitivity of 0.89 and specificity of 0.26 at the cut-off score of 2 and higher. The total Cronbach's alpha coefficient was 0.38 and Cohen's kappa ranged between 0.5 and 0.8. Conclusion: The current study showed that the Farsi version of the SAPAS was relatively less efficient, in term of validity and reliability, in the screening of PD in the population.

  20. A Mechanistic Reliability Assessment of RVACS and Metal Fuel Inherent Reactivity Feedbacks

    Energy Technology Data Exchange (ETDEWEB)

    Grabaskas, David; Brunett, Acacia J.; Passerini, Stefano; Grelle, Austin

    2017-09-24

    GE Hitachi Nuclear Energy (GEH) and Argonne National Laboratory (Argonne) participated in a two year collaboration to modernize and update the probabilistic risk assessment (PRA) for the PRISM sodium fast reactor. At a high level, the primary outcome of the project was the development of a next-generation PRA that is intended to enable risk-informed prioritization of safety- and reliability-focused research and development. A central Argonne task during this project was a reliability assessment of passive safety systems, which included the Reactor Vessel Auxiliary Cooling System (RVACS) and the inherent reactivity feedbacks of the metal fuel core. Both systems were examined utilizing a methodology derived from the Reliability Method for Passive Safety Functions (RMPS), with an emphasis on developing success criteria based on mechanistic system modeling while also maintaining consistency with the Fuel Damage Categories (FDCs) of the mechanistic source term assessment. This paper provides an overview of the reliability analyses of both systems, including highlights of the FMEAs, the construction of best-estimate models, uncertain parameter screening and propagation, and the quantification of system failure probability. In particular, special focus is given to the methodologies to perform the analysis of uncertainty propagation and the determination of the likelihood of violating FDC limits. Additionally, important lessons learned are also reviewed, such as optimal sampling methodologies for the discovery of low likelihood failure events and strategies for the combined treatment of aleatory and epistemic uncertainties.